1 W415-0689 / 06.25.08 INST ALLA TION AND OPERA TION INSTRUC TIONS W olf Steel Ltd., 24 Napoleon Rd ., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 ww w .napoleonreplaces .com • ask@napoleon.on.ca CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ANDARDS: CR97-003 ● CAN-2.
2 W415-0689 / 06.25.08 ! W ARNING PG 2-5 INTRODUCTION W arranty General Instructions General Information / Rates and Ef fi ciencies Care of Glass and Plated Parts Dimensions 5-7 INST ALLA TION Gas In.
3 W415-0689 / 06.25.08 NAP OL E ON® products are manuf actured under th e strict Standar d of the world recognized ISO 9001 : 2000 Q uality Assur ance Certifi cate. NAP OL EON ® products are designed with superior components and materials, assembled by train ed cra ftsmen who tak e great pride in their work .
4 W415-0689 / 06.25.08 THIS GAS APPLIANCE SHOULD BE INST ALLED AND SERVICED BY A QUALIFIED INST ALLER to conform with local codes. Installation practices vary from region to region and it is important.
5 W415-0689 / 06.25.08 FIGURES 1a-c DIMENSIONS Note: All gas connections must be contained within the appliance when complete. 1. The appliance is designed to accept a 1/2” gas supply line. The appliance is equipped with a 1/2” manual shut-off valve.
6 W415-0689 / 06.25.08 ! W ARNING CLEARANCES T O COMB USTIBLES MINIMUM CLEARANCES TO COMBUSTIBLES: - 18” to top - 1” to sides - 8” to bottom - 0” to rear Do NOT use the appliance if any part has been under water . Call a quali fi ed service technician IMMEDIA TEL Y to have the appliance inspected for damage to the electrical circuit.
7 W415-0689 / 06.25.08 G G J I K A C D E F H B B INST ALLA TIONS CANADA U.S.A. A 8 INCHES 8 INCHES Clearance above grade, veranda porch, deck or balcony . B 12 INCHES 9 INCHES Clearance to windows or doors that open. C 12 INCHES* 12 INCHES* Clearance to permanently closed windows.
8 W415-0689 / 06.25.08 2 MOUNTING BRACKET 4 3 KEYHOLE INSTALLATION TEMPLATE TORCH MOUNTING FRAME CABINET 1 NOTE: It is recommended that all fasteners be stainless steel. 1. Using the installation template (W122-0401) supplied, determine the best mounting location for your new T orch.
9 W415-0689 / 06.25.08 RAIN T ABS DOOR REMO V AL GLASS REMO V AL Having removed the door , lay on a smooth fl at surface, face down. There are 4 glass retainers that need to be bent away from the glass to release it from the frame. Do not pry on the glass.
10 W415-0689 / 06.25.08 2. Install the trim bracket supplied in your manual baggie to the fi rebox using 3 screws. DOOR CHAIN SLOT FRAME (REAR VIEW) TRIM BRACKET 1/4” ( APPROX.) CONTROL DOOR 1/4” ( APPROX.) With the control door closed, af fi x the logo to the front face of the control door at the bottom left corner .
11 W415-0689 / 06.25.08 LK8 LIGHT INST ALLA TION (OPTIONAL) 1 . T urn off the electrical and gas supply to the appliance. 2 . Remove the frame from the unit by removing the the 2 stainless steel hex head securing screws from the bottom and lifting the frame off of the top trim bracket.
12 W415-0689 / 06.25.08 O S A A. This appliance is equipped with an ignition device which automatically lights the burner . Do not try to light by hand. B. Before operating, smell all around the appliance area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor .
13 W415-0689 / 06.25.08 Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner . The flame may not appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame color to be established.
14 W415-0689 / 06.25.08 # P ART NO. DESCRIPTION 1 W225-0223 DOOR FRAME 2* W562-0008 DOOR GASKET 3 W010-1959 GLASS C / W GASKET 4* W300-01 10 GLASS 5 W100-01 1 1 BURNER 6 W357-0006 IGNITOR 7 W190-0026 .
15 W415-0689 / 06.25.08 TR OUBLE SHOO TING GUIDE BEFORE A TTEMPTING TO TROUBLESHOOT , PURGE YOUR UNIT AND INITIALL Y LIGHT THE IGNITOR AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED.
16 W415-0689 / 06.25.08 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS.
An important point after buying a device Napoleon Fireplaces GSST8P (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Napoleon Fireplaces GSST8P yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Napoleon Fireplaces GSST8P - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Napoleon Fireplaces GSST8P you will learn all the available features of the product, as well as information on its operation. The information that you get Napoleon Fireplaces GSST8P will certainly help you make a decision on the purchase.
If you already are a holder of Napoleon Fireplaces GSST8P, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Napoleon Fireplaces GSST8P.
However, one of the most important roles played by the user manual is to help in solving problems with Napoleon Fireplaces GSST8P. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Napoleon Fireplaces GSST8P along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center