Revised 06-06 Catalog Section 10 Temperature Scanner/Pyrometer

TDXM Model

Murphy TDXM — TDXM-00064B diagram (page 1)
Fig. 1
C US■Scans Up To 24 Channels ■ Three (3) Adjustable Trip Points Per Channel ■ Accepts Any Combination of “J” or “K” Type Grounded or Ungrounded Thermocouples ■ 2 Separate Groups with Deviation Trip Functions Selectable ■ Powered By 10 to 32 VDC Systems ■ RS485 Serial Communications Port ■ Uses MConfigTMConfiguration and Monitoring Software ■ CSA Certified for Use in Class I, Division 2, Groups “C & D” Hazardous Locations Description The innovative new TDXM now gives you a unique conand temperature units can be selected as °F or °C of stop bits, and slave node number can be set using figurable temperature scanner/pyrometer with a built-in readout for each channel. Unused channels can be the keypad. Communication is half-duplex. Modbus® power supply. A new design features a 7-character, 7-segset to “Ignore” and will not be seen in the display RTU function codes 3 and 6 are supported. ment Liquid Crystal Display window with 1/2 inch (13 and will not cause fault trips. Specifications mm), easy-to-read characters. Also located on the faceControl Options Power Input (Operating Voltages): 1032VDC, plate are membrane keys for easy configuring. Highly reliable and versatile, the TDXM accepts up to Each TDXM model features three outputs: 2 Field 750 mW max. 24 type “J” or “K” grounded or ungrounded* thermoEffect Transistor (FET) outputs and 1 Form-C Relay Sensor Inputs: Up to 24 type “J” or “K” grounded or couples. Each channel has three (3) adjustable setoutput. Each channel has 3 setpoints, one for each of ungrounded* thermocouples. points SP1, SP2 and SP3. The SP1, SP2 and SP3 the outputs. This allows for greater system flexibility Outputs: Two (2) Outputs 0.5 A, 350 VDC, FET-sink Setpoints correspond to the SP1, SP2 and SP3 outputs. by grouping sets of channels through one output. to ground to trip. Additionally it has the selectable feature to monitor and One (1) Form “C” Solid State Relay Output 0.125 A, Setpoint History alarm or shutdown on deviation from an average from up 350 VDC/240 VAC. to two groups of temperatures (GRP/DEV; deviation from The TDXM stores the last setpoint trip for each output NOTE: The form “C” relay output is de-energized for a trip average). One group could be exhaust temperatures and in non-volatile memory. For instance, if SP1of channel condition. The NC terminal is closed and the NO terminal is 1 was the last SP1 tripped, the LCD display will read: open for trip. another group could be bearing temperatures. SP1 1 when the Setpoint History is accessed for SP1. Communications: RS485 Serial Port, MODBUS® The TDXM is capable of communicating with controllers, RTU slave. PLC’s, computers or SCADA (Supervisory Control & Sensor Inputs and Operating, Storage, and Display Temperature: -40 to Data Acquisition) systems by a built-in RS485 serial comTerminals 85°C (-40 to 185F). munications port. The TDXM accepts up to 24, either “J” or “K” type The TDXM-DC is available for 10 - 32 VDC systems. Sensor Scan Rate: Scans all channels in 2 seconds. grounded or ungrounded* thermocouples using 24 Range: Type K: 0 - 1999°F (0 - 1093°C); Type J: 0 - pairs of screw type connections. Each pair has a jumper User Interface (Faceplate) 1538°F (0 - 837°C). from the factory. Any tripped setpoint is detected within The User Interface includes a numeric LCD display 2 seconds after the set point is exceeded. Display Type: Custom 7-segment, 7-character, backand a 5-button membrane keypad for readout and lit type with temperature units indication and setchannel configuration. Thermocouple types can be RS485 Serial Port point trip indication. selected and setpoints entered through a series of The RS485 serial port (MODBUS®† RTU slave) on Accuracy: Cold junction: Better than ±0.5°C (1.0°F). setup menus, see “Setup Menus” section. the back of the module is provided for communicating Type “J” or “K”: ±1°C (2°F); 38 - 1093°C with micro-controllers, PC’s, PLC’s and SCADAsys- (100 - 1999°F). Thermocouple Types tems (see “Typical Wiring Diagrams”). It is recomCold Junction Compensation: -40 to 85°C (-40 to 185F). Each of the 24 channels on the TDXM can be conmended that a termination resistor (customer supplied) Open Thermocouple Detection: Drives channel reading high. figured as either “J” or “K” type thermocouples be used when the TDXM is the last device connected *We recommend the use of ungrounded thermocouples. in a daisy-chain configuration. The Baud rate, number Errors in readings with grounded thermocouples can be the result of differences in grounding between different devices. *We recommend the use of ungrounded thermocouples. Errors in readings with grounded thermocouples can be the result of differences in grounding between different devices. † MODBUS® is a registered trademark of AEG Schneider Automation Inc.
Page 2 of the Murphy TDXM user manual — Replacement Parts Plug, kit, TDXM: Terminal Plug replacement kit-P/N
Page 2 · click to enlarge
Page 2

TDXM Module Dimensions Front

Side Back

TDXM-DC POWER INPUT10-32 VDC OUTPUT TYPE AND RATING:

SP1: FET, OPEN DRAIN, 350 VDC, 0.5A MAX. SP2: FET, OPEN DRAIN, 350 VDC, 0.5A MAX.

5-1/4 in. (133 mm) TDXM

WHEN INSTALLED PER MURPHY DRAWING 10-08-0006 U

SP3: SSR, FORM C, 350 VDC/240 VAC, 0.12A MAX.

C US

VOLTAGE: 10VDC MIN, 32VDC MAX, 500mW, NEG GND X,

NON-INCENDIVE FIELD WIRING CONNECTIONS

TC TYPE/UNITS (SETUP 1) 0 = IGNORE 1 = TYPE J TC. DEG F 2 = TYPE K TC. DEG F 3 = TYPE J TC. DEG C 4 = TYPE K TC. DEG C

SETUP NUMBERS 0 = EXIT 1 = TC TYPE UNIT 2 = OFFSET 3 = SETPOINTS 4 = GRP/DEV A (SP1 OUT) GRP/DEV B (SP2 OUT) 5 = CH SCAN DELAY 6 = CJ DISPLAY 7 = RTU/BAUD 8 = UNIT ID

CSA CERTIFIED FOR CL I, DIV 2, GRPS C & D D

FOR USE IN CLASS I DIV. 2, GROUPS C & D LOCATIONS WHEN INSTALLED PER

6-1/2 in. (165 mm)

F W M U RP HY H

MURPHY DRAWING 10-08-0006

RTU/BAUD (SETUP 7) BAUD SETUP 0 = 9600 (N, 8, 1) 1 = 19.2K (N, 8, 1) 2 = 38.4K (N, 8, 1) 3 = 9600 (N, 8, 2) 4 = 19.2K (N, 8, 2) 5 = 38.4K (N, 8, 2)

SERIAL NO: X9-xxxx-X-X

THERMOCOUPLE INPUTS

(WHITE / YELLOW)

SP HISTORY

MODEL NO: TDXM-DC

CJ DISPLAY (SETUP 6) 0 = DISABLE 1 = ENABLE, DEG F 2 = ENABLE, DEG C

CHANNEL

SP1 - 3

SCROLL

ENTER

(SETUP) (SETUP)

6-1/2 in. (165 mm)

49/64 in. (19 mm)

3-3/8 in. (86 mm) minimum mounting clearence.

6.0 in. (152.3 mm)

3.0 in. (76 mm)

3.0 in. (76 mm)

Mounting Hole

5.50 in. (140 mm)

F W M U RP HY H

SERIAL NO: X9-xxxx-X-X

6.0 in. (152.3 mm)

0.156 in. (4 mm) dia. 4 places 5.50 in. (140 mm) Panel

Murphy TDXM — F W M U RP HY H diagram (page 2)
Fig. 2

For Outdoor Use, the TDXM should be mounted in a weatherproof enclosure

Head/Module TDXM-DC24-channel model, 10-32 VDC powered. TDXM-DC W/SP3 Latch : Same as TDXM-DC but

Shipping Weights and Dimensions Shipping Weight (all Models): 3 lb. (1.36 kg) approximately. Shipping Dimensions (all Models): 5-1/2 x 9 x 9-1/2 in.

(140 x 229 x 241 mm) approximately. Warranty A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm

Replacement Parts Plug, kit, TDXM: Terminal Plug replacement kit-P/N

10-00-7848.

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time. MURPHY, the Murphy logo are registered and/or common law trademarks of Murphy Industries, Inc. This document, including textual matter and illustrations, is copyright protected by Murphy Industries, Inc., with all rights reserved. (c) 2006 Murphy Industries, Inc. www.fwmurphy.com 918.317.4100 Email: sales@fwmurphy.com

TDXM-00064B page 2 of 2

Show 5 more labels / short text on this page
® · Keps Nut · Lock washer Screw · Mounting · Hole

Ask about the Murphy TDXM

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Murphy TDXM

Be the first to ask — other owners or our team will answer.

Original document

Murphy TDXM manual PDF

2 pages·168 KB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…