Page 1 of the Multi-Tech Systems MVP103 user manual — MultiVOIP ®
Page 1 · click to enlarge
Page 1

MultiVOIP ®

Voice/Fax over IP Gateways

Configuration Guide for MultiVOIP Units deployed with Avaya

TM Communication Manager

Models: MVP-130/210/410/810-AV

Page 2 of the Multi-Tech Systems MVP103 user manual — World Headquarters
Page 2 · click to enlarge
Page 2

Configuration Guide S000299G Analog MultiVOIP Units Models MVP-130/210/410/810-AV for use with Avaya

This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi- Tech Systems, Inc. All rights reserved.

Copyright © 2008, by Multi-Tech Systems, Inc.

Multi-Tech Systems, Inc. makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes. Record of Revisions Revision Date Description A 04/25/03 Initial Release. B 06/19/03 Manual revised to include name change to Avaya Communication Manager. C 08/20/03 Manual revised to include IP Phone Survivability. Software Vs 9.05.28 D 12/26/03 Manual revised to correct IP Phone and FXS port configuration. Software Vs 9.05.28 for MVP210/410/810-AV and software Vs 2.04.17 for MVP130. E 05/10/04 Manual revised for software version 9.06.xx. Added support for additional voice coders, DID, Caller ID remote ping feature, off-hook alerting, and audible message waiting. F 12/07/04 Manual revised to include editorial comments. G 06/26/08 Manual revised to include support for 16xx and 96xx IP Phone Modules, in addition to the 46xx series. This update documents VOIP Software Version 9.06.DV or higher. H 02/23/09 Manual revised to include support for IP phone 4622 and VOIP software version 2.06 for MVP130-AV Patents This Product is covered by one or more of the following U.S. Patent Numbers: 6151333, 5757801, 5682386, 5.301.274; 5.309.562; 5.355.365; 5.355.653; 5.452.289; 5.453.986. Other Patents Pending. Trademark Trademark of Multi-Tech Systems, Inc. is the Multi-Tech logo. Windows and NetMeeting are registered trademarks of Microsoft. Avaya is registered trademark of Avaya Inc.

World Headquarters

Multi-Tech Systems, Inc. 2205 Woodale Drive Mounds View, Minnesota 55112 (763) 785-3500 or (800) 328-9717 Fax: 763-785-9874 http://www.multitech.com

Technical Support Country By Email By Phone Europe, Middle East, Africa support@multitech.co.uk +(44) 118 959 7774 U.S., Canada, all others support@multitech.com (800) 972-2439 or +(763) 717-5863

TM Communication Manager

Page 4 of the Multi-Tech Systems MVP103 user manual — MultiVOIPs in Avaya Communication Manager Systems
Page 4 · click to enlarge
Page 4

Chapter 1 - Introduction

Chapter 1 - Introduction

About This Manual

MultiVOIP models (MVP130-AV, MVP130-AV-FXS, MVP210-AV, MVP410-AV, & MVP810-AV) being used in systems containing Avaya PBX units and controlled by Avaya

TM Communication Manager software differ only slightly from those being used in general voice-over-IP applications. Because this is so, comprehensive information on the general setup of these MultiVOIP units can be found in the MultiVOIP User Guide. However, certain MultiVOIP parameters are unique to operation in Communication Manager systems. This manual describes these parameters.

Multi-Tech Systems MVP103 — Chapter 1 - Introduction diagram (page 4)
Fig. 1 · Chapter 1 - Introduction
Multi-Tech Systems MVP103 — Chapter 1 - Introduction diagram (page 4)
Fig. 2 · Chapter 1 - Introduction
Multi-Tech Systems MVP103 — Chapter 1 - Introduction diagram (page 4)
Fig. 3 · Chapter 1 - Introduction
Multi-Tech Systems MVP103 — Chapter 1 - Introduction diagram (page 4)
Fig. 4 · Chapter 1 - Introduction

Beyond general setup information (like Mechanical Installation, & Cabling, LED definitions, and other general info which are presented in the MultiVOIP User Guide & Quick Start Guide), this software guide presents all the information you need to configure your MultiVOIP for use in a Communication Manager system. It presents information on the MultiVOIP software screens as well as the related Communication Manager screens. The MultiVOIP User Guide remains valuable as a reference source.

MultiVOIPs in Avaya Communication Manager Systems

The Communication Manager build of the MultiVOIP software allows for use of MultiVOIP units in conjunction with IP-equipped Avaya PBX units. These PBXs are equipped with H.323 gatekeeper functionality and support endpoints such as IP phones and MultiVOIP gateways.

In addition to functioning as a gateway, the MultiVOIP also contains an integrated gatekeeper, except MVP130 Models. This allows the MultiVOIP to serve as it’s own alternate gatekeeper should Communication Manager be unavailable. When serving as an alternate gatekeeper, the MultiVOIP processes registration and call routing for it’s local FXS/FXO/DID ports as well as local Avaya IP phones. This is the MultiVOIP’s “gatekeeper survivability” mode.

Each MultiVOIP voice channel can be registered with a primary Communication Manager gatekeeper or one of two optional alternate gatekeepers. The optional gatekeepers can be other Communication Manager gatekeepers or the integrated MultiVOIP gatekeeper.

The diagram below shows a common function for the MultiVOIP unit within the Communication Manager network: the MultiVOIP allows selected callers at a site remote from the Avaya PBX units to have access to the PBX units and all of their extensions without tolls. Voice and fax calls are supported.

Page 5 of the Multi-Tech Systems MVP103 user manual — Figure 1. MultiVOIP in Avaya Communication Manager System
Page 5 · click to enlarge
Page 5

Chapter 1 - Introduction

Multi-Tech Systems MVP103 diagram (page 5)
Fig. 5
Multi-Tech Systems MVP103 diagram (page 5)
Fig. 6
Multi-Tech Systems MVP103 diagram (page 5)
Fig. 7
Multi-Tech Systems MVP103 diagram (page 5)
Fig. 8
Multi-Tech Systems MVP103 diagram (page 5)
Fig. 9
Multi-Tech Systems MVP103 diagram (page 5)
Fig. 10
Multi-Tech Systems MVP103 diagram (page 5)
Fig. 11

Figure 1. MultiVOIP in Avaya Communication Manager System

The MVP810-AV shown in the diagram on the previous page functions as a gateway registered to one of the Communication Managers in the IP network. The MVP810-AV provides survivable calling between the IP Phones, stations (FXS) and trunk (FXO/DID) ports at the remote site should the WAN link go down.

The MultiVOIP will not serve as a survivable gatekeeper for IP phones on the other side of the wan link.

If the WAN link goes down, the MultiVOIP will try to register six times with the Primary Communication Manager Gatekeeper at 3-second intervals. If the Primary gatekeeper does not respond, the MultiVOIP will try to register with the Alternate #1 Communication Manager Gatekeeper six times at 3-second intervals. If the alternate #1 gatekeeper does not respond, the MultiVOIP will register with the Alternate #2 gatekeeper, which is the integrated MultiVOIP gatekeeper. If the MultiVOIP registers to its own gatekeeper, this is gatekeeper survivability mode where the MultiVOIP will process registration and call routing for its local FXS/FXO/DID ports as well as local Avaya IP phones.

While in gatekeeper survivability mode, the MultiVOIP checks for the availability of the primary Communication Manager gatekeeper every 3-minutes. The MultiVOIP will re-register and discontinue its survivability mode automatically when the primary Communication Manager gatekeeper becomes available. Any calls that were established during the "survivable mode" which are still active while the MultiVOIP gateway returns to "subtending mode" to the CM gatekeeper, shall be preserved by the MultiVOIP gatekeeper. When these calls become inactive (idle), the MultiVOIP gatekeeper shall force these endpoints to unregister with the MultiVOIP gatekeeper and re-register with the CM gatekeeper.

If the MultiVOIP is not configured as an alternate gatekeeper, and none of the Primary, Alternate #1, or Alternate #2 CM gatekeepers respond, the MultiVOIP will enter gateway survivable mode (if enabled) and will process calls according to it’s inbound and outbound phone books. In gateway survivable mode, the MultiVOIP will check for the availability of the primary Communication Manager gatekeeper according to the Switching Time Interval programmed into the Communication Manager Parameters screen of the MultiVOIP configuration. The MultiVOIP will exit gateway survivability mode if it is able to register with the Primary CM gatekeeper. Gateway survivability mode is enabled by checking the “Enable Survivability Mode” checkbox in the Communication Manager Parameters screen. If IP phone survivability is required, you must enable gatekeeper survivability mode instead by configuring the MultiVOIP as one of the alternate #1 or alternate #2 gatekeepers.

The following Avaya IP Phone models are supported in gatekeeper survivable mode:

4601 4602 4606 4610 4612 4620 4621 4622 4624 4625 9610 9620 9630 9640 9650 1603 1608 1616

Page 6 of the Multi-Tech Systems MVP103 user manual — Configuring MultiVOIP for Avaya Communication Manager Use
Page 6 · click to enlarge
Page 6

Configuring MultiVOIP for Avaya Communication Manager Use

To configure the MultiVOIP unit within such a system (similar to that in Figure 1), use the Communication Manager Parameters screen within the MultiVOIP program. If “Register with Communication Manager Gatekeeper” is selected, then many parameters must assume default values and those will be grayed out on the screen. In setting up the MultiVOIP unit for Communication Manager use, bear in mind that you may configure the MultiVOIP to operate with any combination of stations (FXS) and/or trunks (FXO/DID).

1. Configure IP Parameters

1a. Configure the IP address, gateway address, and mask used by the MultiVOIP unit in the Configuration |IP Parameters screen of the MultiVOIP program. The IP address must match that used in the Communication Manager “Change Node Names IP” form (dialog box).

1b. DiffServ PHB (Per Hop Behavior) values pertain to a differential prioritizing system for IP packets as handled by DiffServ-compatible routers. There are 64 values, each with an elaborate technical description. These descriptions are found in TCP/IP standards RFC2474, RFC2597, and, for present purposes, in RFC3246, which describes the value 34 (34 decimal; 22 hex) for Assured Forwarding behavior (default for Call Control PHB) and the value 46 (46 decimal; 2E hexadecimal) for Expedited Forwarding behavior (default for Voip Media PHB).

If you wish to use just one DiffServ PHB value, Ayaya recommends the value 46 (46 decimal; 2E hex) for both Call Control and VOIP Media.

1c. If you require that the MultiVOIP get its IP address from a DHCP server, select the “Enable DHCP” option. The DHCP server must be located at the same site as the MultiVOIP so it is available in the event of wan link failure. The DHCP server must issue an IP address that is statically defined on the DHCP server so that the MultiVOIP gets the same IP address all the time.

1d. TDM Routing Option. Calls placed between ports on the same MultiVOIP voice channel board will normally be routed over the MultiVOIP’s internal TDM (Time Division Multiplexed) bus. TDM calls have less delay than calls routed over IP. On MVP410/810-AV models, calls between channels 1-4 or channels 5-8 will be TDM routed. Calls between voice boards (for example, channel 1 calling channel 5) will be IP routed. If you require all calls to be IP routed, disable the “use TDM Routing for Intra-Gateway Calls” option. This should not normally be required, so it is recommended that you leave TDM Routing enabled.

Multi-Tech Systems MVP103 — Configuring MultiVOIP for Avaya Communication Manager Use diagram (page 6)
Fig. 12 · Configuring MultiVOIP for Avaya Communication Manage…
Page 7 of the Multi-Tech Systems MVP103 user manual
Page 7 · click to enlarge
Page 7
Multi-Tech Systems MVP103 diagram (page 7)
Fig. 13

1e. TCP/UDP port requrements. To ensure proper functioning of the MultiVOIP, the TCP/UDP network connection must not be blocked on the network connection between the MultiVOIP and CM. The UDP ports used by the MultiVOIP are as follows:

ChannelRTP PortRTCP PortT38 Port 1500650075008 2501650175018 3502650275028 4503650375038 5504650475048 6505650575058 7506650675068 8507650775078

The TCP ports used by the MultiVOIP are as follows:

H.225 Listen Port – User configured for each channel in the CM Settings screen (default 1721 – 1728) H.225 Client Port – Dynamic (16000 – 20000) H.245 Listen Port – Dynamic (16000 – 20000) RAS Client Port – Dynamic (16000 – 20000)

1f. Emergency Transfer. Emergency transfer allows local analog telephones to access the local CO and to answer telephone calls during a power failure. For the various products the features operate as follows: MVP210-AV Port 1 is connected to Port 2 MVP410-AV Port 1 is connected to Port 2 Port 3 is connected to Port 4 MVP810-AV Port 1 is connected to Port 2 Port 3 is connected to Port 4

For example, suppose ports 1 and 3 of MVP410-AV are configured as FXS with telephones

attached. Ports 2 and 4 are configured as FXO trunks with CO lines attached. If there is a power failure, the telephones on ports 1 and 3 would automatically be connected to the CO lines attached to ports 2 and 4 allowing inbound and/or outbound call to be make.

Page 8 of the Multi-Tech Systems MVP103 user manual
Page 8 · click to enlarge
Page 8
2. Configure Interface Parameters.

2a. Determine which voice channels will be stations (FXS), trunks (FXO/DID), or disabled. Configure them as such in the Configuration | Interface screen of the MultiVOIP GUI.

Multi-Tech Systems MVP103 diagram (page 8)
Fig. 14

2b. If you are configuring a DID-DPO (Direct Inward Dial – dial-pulse originating) interface for DID incoming calls, you need to chose DID-DPO from the pull down menu for Interface Type. You also have to set the DID Options Start Modes; Immediate Start, Wink Start, or Delay Dial.

Immediate Start allows the MultiVOIP to detect the off-hook condition at the originating end of the call and becomes ready to receive the digits immediately.

Wink Start allows the MultiVOIP to detect the off-hook condition at the originating end of the call. The MultiVOIP then reverses the battery polarity for a specified time (140-290 ms; a “wink”) and then becomes ready to receive the dialed digits. You can select the Wink Timer duration (140 to 290 ms).

Delay Dial allows the MultiVOIP to detect the off-hook condition at the originating end of the call. Then the MultVOIP reverses battery polarity for a specified time (reverse polarity duration has a wider acceptable range than Wink Start) and then becomes ready to receive dialed digits.

2c. Enable the “Message Waiting Light” feature if you have FXS Interface selected and are using an Avaya analog telephone with Message Waiting indicator or enable “Stutter Dial Tone” if you are

Page 9 of the Multi-Tech Systems MVP103 user manual
Page 9 · click to enlarge
Page 9

using a non-Avaya analog telephone. This station must be properly administered in the Audix Voice Mail System for the message waiting feature to work.

2d. Activate the “Caller ID” feature if you have FXS Interface selected and are using an analog telephone with caller ID display. The MultiVOIP will output Caller ID information, if received, between the first and second rings.

2e. Activate “Caller ID” on FXO interfaces if the attached line supports it. The MultiVOIP will capture the Caller ID information, if provided, between the first and second rings and will forward the information to CM.

a) The ‘Message Waiting’ field must be enabled and set to “led” if this feature is intended to be

supported on the MultiVOIPs analog station port.

b) Similarly, the following features must be enabled as desired:

  • Switchhook flash
  • Call Waiting Indication
  • Attendant Call Waiting Indication
Page 10 of the Multi-Tech Systems MVP103 user manual
Page 10 · click to enlarge
Page 10
3. Configure Voice/Fax Parameters.

3a. In the MultiVOIP’s Configuration | Voice/Fax Parameters screen, configure the voice channels for a voice coder that is supported by Communication Manager.

Multi-Tech Systems MVP103 diagram (page 10)
Fig. 15

The voice coder selected must match the voice coders listed in the ip-codec-set for the network region the MultiVOIP resides in. If only G.729 is listed in the ip-codec-set, select G.729 on the MultiVOIP. If G.711 is listed before G.729 in the ip-codec-set, select G.711, G.729 on the MultiVOIP. If G729 is listed before G.711 in the ip-codec-set, select G.729, G.711 on the MultiVOIP.

There is one exception, if only G.711 is listed in the ip-codec-set, you must select G.711, G.729 on the MultiVOIP. This will allow support for G.711 for CM managed calls, and will allow support for G.729 for survivable mode calls. The MultiVOIP only supports G.729 in survivable mode.

The table below shows the bandwidth required per voice channel based on the codec selected and the CM “Frames per Packet” setting in the “Change IP-Codec-Set” screen.

Bandwidth per Channel Voice Frames per IP Packet Coder1234 G.72940K bps24K bps18K bps16K bps G.71196K bps80K bps74.7K bps72K bps

3b. If the CM customer desires that a particular FXS port is to operate as a “hot extension”, set the “auto call/off-hook alerting” feature to auto call and enter the desired destination number in the “phone number” field. Enabling this feature allows an analog phone user to be able to lift his/her

Page 11 of the Multi-Tech Systems MVP103 user manual
Page 11 · click to enlarge
Page 11

handset (and without dialing the number) immediately call the far-end party. To prevent toll fraud on FXO trunk ports, set the “autocall enable” feature and enter the phone number for a receptionist or auto-attendent. 3c. The MultiVOIP supports off-hook alerting on FXS ports. To enable the feature, set the “auto call/off-hook alert” feature to “off-hook alert” and enter the destination number in the “phone number” field. If the user lifts the handset, but does not dial a number, dial tone will be heard for 10 seconds, followed by intercept tone for the number of seconds configured in the “off-hook alert timer” field. If this timer expires, a call will automatically be placed to the destination number in the “phone number” field. 4. Configure the station (FXS) channels in the Communication Manager Parameters screen.

Communication Manager MultiVOIPFXS Channels
Multi-Tech Systems MVP103 diagram (page 11)
Fig. 16

4a. Make sure the “Register with Communication Manager Gatekeeper” option is checked.

4b. Configure Call Signaling Port. This needs to be unique on each registered FXS channel and must fall within the range of port values supported by Communication Manager. Typically, it is OK to use the default values 1721-1728 on channels 1-8 respectively.

Page 12 of the Multi-Tech Systems MVP103 user manual
Page 12 · click to enlarge
Page 12

4c. Configure Gateway Name (optional). This is the name that gets displayed when viewing Call Progress statistics for this channel. If used, the MultiVOIP’s Gateway Name must match the name used in the Communication Manager “Node-Names IP” form.

Multi-Tech Systems MVP103 diagram (page 12)
Fig. 17

4d. Configure Phone Number / Extension. This must match the extension configured for this station in the Communication Manager “station” form. If “ Message Waiting Indicator” is required for this extension, set this option to “led” in the CM “station” form.

Multi-Tech Systems MVP103 diagram (page 12)
Fig. 18
Page 13 of the Multi-Tech Systems MVP103 user manual
Page 13 · click to enlarge
Page 13

Connection” field must be set to “y” and the “IP Audio Hairpinning” field must be set to “n.”

Multi-Tech Systems MVP103 diagram (page 13)
Fig. 19

4e. Configure Security Code. This must match the security code configured in the Communication Manager “Station” form (see first graphic in step 4d).

4f. Configure Primary Gatekeeper IP Address. This must be configured to match the IP address of the CLAN or PROCR card in the “IP Node Names” form of the primary CM gatekeeper. Do not change the RAS port from the default 1719 and leave the Gatekeeper Name field blank.

Multi-Tech Systems MVP103 diagram (page 13)
Fig. 20

4g. Configure IP addresses for Alternate Gatekeeper 1 and Alternate Gatekeeper 2 (optional). These must be configured to match the IP address of the respective CLAN or PROCR card in the PBX unit serving as the Alternate Gatekeeper. This field appears in IP Node Names form of the Communication Manager software for that PBX. If you are using the MultiVOIP Gatekeeper as an alternate gatekeeper, enter the IP address of the MultiVOIP. The alternate MultiVOIP gatekeeper must appear after any Communication Manager alternate gatekeepers.

Page 14 of the Multi-Tech Systems MVP103 user manual — Communication Manager MultiVOIP: FXO Channels
Page 14 · click to enlarge
Page 14
5. Configure trunk (FXO) channels in the Communication Manager Parameters screen.

Communication Manager MultiVOIP: FXO Channels

Multi-Tech Systems MVP103 — Communication Manager MultiVOIP: FXO Channels diagram (page 14)
Fig. 21 · Communication Manager MultiVOIP: FXO Channels

5a. Make sure the “Register with Communication Manager Gatekeeper” option is checked.

Page 15 of the Multi-Tech Systems MVP103 user manual
Page 15 · click to enlarge
Page 15

5b. Configure Call Signaling Port. Unlike station (FXS) ports, which require a unique value for each channel, trunk (FXO) ports require that the same Call Signaling Port value be used on all trunk (FXO) ports that are registered to the same Communication Manager PBX. Configure this to a unique value that is not being used by another station (FXS) or trunk (DID) port on this MultiVOIP unit. This port value must fall within the range of port values supported by Communication Manager and should match the “Far-end Listen Port” value configured in the Communication Manager “Signaling Group” (“Display Signaling Group”) form (dialog box). All FXO ports on this MultiVOIP will use the same Signaling Group for communication with the CM Server.

Multi-Tech Systems MVP103 diagram (page 15)
Fig. 22

Group Type = h.323 Remote Office? = n RRQ Required? = y Direct IP-IP Audio Connection? = y IP Audio Hairpinning? =n Calls Share IP Sig Connection =y

5c. Configure Delay before Dial value. This is the delay after the MultiVOIP goes off hook before it dials a number to the attached PSTN line. Some PSTN lines may require more than the default 400 ms value. Configure as appropriate for the PSTN lines you are using. If you are not sure, leave the default value in place.

5d. Configure Gateway Name. This should match the value configured for this MultiVOIP unit in the Communication Manager “IP Node Names” and “Signaling Group” forms.

5e. Configure Primary Gatekeeper IP Address. This must be configured to match the IP address of the CLAN or PROCR card in the “IP Node Names” form of the primary Communication Manager Gatekeeper unit. Do not change the RAS Port and leave the Gatekeeper name field blank.

5f. Configure IP addresses for Alternate Gatekeeper1 and Alternate Gatekeeper 2 (optional). These must be configured to match the IP address of the respective CLAN or PROCR card in the PBX unit serving as the Alternate Gatekeeper. This field appears in IP Node Names form of the Communication Manager software for that PBX. If you are using the MultiVOIP Gatekeeper as an alternate gatekeeper, enter the IP address of the MultiVOIP. The alternate MultiVOIP gatekeeper must appear after any Communication Manager alternate gatekeepers.

Page 16 of the Multi-Tech Systems MVP103 user manual
Page 16 · click to enlarge
Page 16

5g. To accommodate the MultiVOIP unit, the following fields in the Communication Manager “Trunk Group – Page 1” form must be set as shown:

Dial Access? = y Service Type = tie Group Type = ISDN Carrier Medium = IP/H.323

Multi-Tech Systems MVP103 diagram (page 16)
Fig. 23

5h. To accommodate the MultiVOIP unit, all of the MultiVOIP’s FXO channels must be listed as trunk- group members in the Communication Manager Trunk Group form (“Change Trunk-Group” dialog box).

Multi-Tech Systems MVP103 diagram (page 16)
Fig. 24

For example, if four channels of an MVP810-AV are configured as FXO, four trunk group numbers must be listed, as above.

Page 17 of the Multi-Tech Systems MVP103 user manual
Page 17 · click to enlarge
Page 17
6. Configure trunk (DID) channels in the Communication Manager Parameters screen.
Communication Manager MultiVOIPDID Channels
Multi-Tech Systems MVP103 diagram (page 17)
Fig. 25

6a. Make sure the “Register with Communication Manager Gatekeeper” option is checked.

Page 18 of the Multi-Tech Systems MVP103 user manual
Page 18 · click to enlarge
Page 18

6b. Configure Call Signaling Port. Unlike station (FXS) ports, which require a unique value for each channel, trunk DID ports require that the same Call Signaling Port value be used on all DID trunk ports that are registered to the same Communication Manager PBX. Configure this to a unique value that is not being used by another station (FXS) or trunk (FXO) port on this MultiVOIP unit. This port value must fall within the range of port values supported by Communication Manager and should match the “Far-end Listen Port” value configured in the Communication Manager “Signaling Group” (“Display Signaling Group”) form (dialog box). All DID trunk ports on this MultiVOIP will use the same Signaling Group for communication with the CM Server.

Multi-Tech Systems MVP103 diagram (page 18)
Fig. 26

Group Type = h.323 Remote Office? = n RRQ Required? = y Direct IP-IP Audio Connection? = y IP Audio Hairpinning? = n Calls Share IP Sig Connection =y 6c. Configure Gateway Name. This should match the value configured for this MultiVOIP unit in the Communication Manager “IP Node Names” and “Signaling Group” forms.

6d. Configure Primary Gatekeeper IP Address. This must be configured to match the IP address of the CLAN or PROCR card in the “IP Node Names” form of the primary Communication Manager Gatekeeper unit. Do not change the RAS Port and leave the Gatekeeper name field blank.

6e. Configure IP addresses for Alternate Gatekeeper1 and Alternate Gatekeeper 2 (optional). These must be configured to match the IP address of the respective CLAN or PROCR card in the PBX unit serving as the Alternate Gatekeeper. This field appears in IP Node Names form of the Communication Manager software for that PBX. If you are using the MultiVOIP Gatekeeper as an alternate gatekeeper, enter the IP address of the MultiVOIP. The alternate MultiVOIP gatekeeper must appear after any Communication Manager alternate gatekeepers.

Page 19 of the Multi-Tech Systems MVP103 user manual
Page 19 · click to enlarge
Page 19

6f. To accommodate the MultiVOIP unit, the following fields in the Communication Manager “Trunk Group – Page 1” form must be set as shown:

Dial Access? = n Service Type = tie Group Type = ISDN Carrier Medium = IP/H.323

Multi-Tech Systems MVP103 diagram (page 19)
Fig. 27

6g. To accommodate the MultiVOIP unit, all of the MultiVOIP’s DID channels must be listed as trunk- group members in the Communication Manager Trunk Group form (“Change Trunk-Group” dialog box).

Multi-Tech Systems MVP103 diagram (page 19)
Fig. 28

For example, if four channels of an MVP810-AV are configured as DID, four trunk group numbers must be listed, as above.

Page 20 of the Multi-Tech Systems MVP103 user manual
Page 20 · click to enlarge
Page 20
7. Configure MultiVOIP gatekeeper (except for the MVP130 Models) to provide survivability to IP phones and local FXS/FXO/DID ports.

If you are using Avaya IP phones in addition to the MultiVOIP, you must configure the MultiVOIP gatekeeper to provide survivability for the IP phones and local FXS/FXO/DID ports in the event of WAN link failure.

7a. In the MultiVOIP’s Gatekeeper |Endpoints screen, add predefined endpoints to the gatekeeper.

Multi-Tech Systems MVP103 diagram (page 20)
Fig. 29

One endpoint entry is required for each FXS port or IP phone. Only one entry is required for one or more FXO ports per MultiVOIP gateway. Only one entry is required for one or more DID ports per MultiVOIP gateway.

7b. To add an entry for a MultiVOIP FXS port, configure Endpoint Type, Product ID, Names, Phones, Registration IP, and Security code fields as indicated below. Configure the Names field with a unique descriptive identifier. The information contained in the Names and Phones fields will be used for Caller ID purposes in survivable mode. Configure Phones and Security Code to match the values configured for this station in Communication Manager. The Registration IP should match the IP address of the MultiVOIP where the FXS port is located. This could be the IP address of this very same MultiVOIP or another MultiVOIP. Leave the other fields blank. One entry is required for each MultiVOIP FXS port that is configured to register with Communication Manager. Click OK to accept this entry. Repeat the above steps to add additional FXS station port entries.

If the autocall feature is being used to route incoming FXO trunk calls to an extension (1000, etc.,) at the main site, you can program a second entry in the “Phones” field to 1000 to route incoming FXO trunk calls to a given FXS station to cover the autocall situation in Gatekeeper Survivable mode.

Multi-Tech Systems MVP103 diagram (page 20)
Fig. 30
Page 21 of the Multi-Tech Systems MVP103 user manual
Page 21 · click to enlarge
Page 21

7c. To add an entry for MultiVOIP FXO ports, configure Endpoint Type, Product ID, Names, Registration IP, and Call Signalling Port fields as indicated below. Configure the Names field with a unique descriptive identifier for the FXO trunk. This same name will be used later to map Outbound Phone Book entries with specific digit patterns (area codes, etc.) to this FXO trunk, and for Caller ID purposes in survivable mode. The Registration IP should match the IP address of the MultiVOIP where the port is located. This could be the IP address of this very same MultiVOIP or another MultiVOIP. Leave the other fields blank. Only one entry is required for one or more ports on a given MultiVOIP. For example, if the MultiVOIP has four FXO ports, only one gatekeeper entry should be added. Click OK to accept this entry.

Multi-Tech Systems MVP103 diagram (page 21)
Fig. 31

7d. To add an entry for MultiVOIP DID ports, configure Endpoint Type, Product ID, Names, Registration IP, and Call Signalling Port fields as indicated below. Configure the Names field with a unique descriptive identifier for the DID trunk. This name will be used for Caller ID purposes in survivable mode. The Registration IP should match the IP address of the MultiVOIP where the DID port is located. This could be the IP address of this very same MultiVOIP or another MultiVOIP. Leave the other fields blank. Only one entry is required for one or more ports on a given MultiVOIP. For example, if the MultiVOIP has four DID ports, only one gatekeeper entry should be added. Click OK to accept this entry.

Multi-Tech Systems MVP103 diagram (page 21)
Fig. 32
Page 22 of the Multi-Tech Systems MVP103 user manual
Page 22 · click to enlarge
Page 22

7e. To add an entry for an IP phone, configure Endpoint Type, Product ID, Names, Phones, and Security code fields as indicated below. Configure Phones and Security Code to match the values configured for this IP phone in Communication Manager. Leave the other fields blank. One entry is required for each IP phone located at the same site as this MultiVOIP. Do not create entries for IP phones located at other sites. They will not be able to register with this MultiVOIP in the event of a wan link failure. Click OK to save this entry. Repeat the above steps to add additional IP phone entries. The MVP210, MVP410, and MVP810 support 5,10, or 15 IP phones respectively.

Multi-Tech Systems MVP103 diagram (page 22)
Fig. 33

The IP phones must be configured to use DHCP and the DHCP server must be located at the same site as the MultiVOIP and IP phones. This is the only means by which the IP phones are made aware of alternate gatekeepers, such as the MultiVOIP gatekeeper when the CM is unavailable due to WAN link failure.

Refer to the following Avaya documents for instructions on how to configure the DHCP server.

  • 4600 Series IP Telephone Lan Administrator’s Guide (Avaya document number 555-233-507). Read the section titled “DHCP” under “Server Administration”.
  • Avaya one-x Deskphone Edition for 9600 Series IP Telephones Administrator’s Guide Release 1.5 (Avaya document number 16-300698). Read the section titled “DHCP and File Server” under “Server Administration”.
  • Avaya one-x Deskphone Value Edition 1600 Series IP Telephones Administrator’s Guide Release 1.0 (Avaya document number 16-601443). Read the section titled “DHCP Server Administration”.

Your DHCP server must utilize site-specific options (SSON) #176 (46xx models) and/or #242 (16xx, 96xx models) which are IP Telephone-specific DHCP options specifying information such as TFTP server and Definity CLAN IP address. The MultiVOIP IP address must be listed at the end of the string. MCIPADD=xxx.xxx.xxx.xxx,yyy.yyy.yyy.yyy where xxx.xxx.xxx.xxx is one or more IP addresses used for Definity/CM CLAN IP boards and yyy.yyy.yyy.yyy is the MultiVOIP’s IP address.

Page 23 of the Multi-Tech Systems MVP103 user manual
Page 23 · click to enlarge
Page 23

7f. Configure the “Survivable GK Node Name” field with the node name previously given to the MultiVOIP in the “Node-Names IP” form.

Avaya IP phones running firmware version 2.0 or higher require CM 2.0.1 or higher to work in survivable mode with the MultiVOIP. When these phones register with the CM, they replace the list of gatekeepers acquired from the DHCP server (including the MultiVOIP) with a new list of gatekeepers acquired from CM. This differs from 1.x IP phone firmware where the gatekeeper list sent to the IP phone from CM was appended to the list of gatekeepers acquired from the DHCP server. When using CM 2.0.1 or higher, configure the “Survivable GK Node Name” field in the station form for the IP phone. By doing this, the MultiVOIP will be included in the list of gatekeepers sent to the IP phone by CM.

Multi-Tech Systems MVP103 diagram (page 23)
Fig. 34

7g. The completed Endpoints screen is shown below:

Multi-Tech Systems MVP103 diagram (page 23)
Fig. 35

7h. Click on Save Setup|Save GK Parameters to save the gatekeeper settings.

Page 24 of the Multi-Tech Systems MVP103 user manual
Page 24 · click to enlarge
Page 24
8. Create Outbound Phone Book entries to allow the mapping of digit patterns (area codes, 911 calls, etc) to FXO trunks during gatekeeper survivable mode.

When a survivable call comes in from the IP network to the MultiVOIP gatekeeper, the MultiVOIP will search through the Outbound Phone book entries in an attempt to find an entry whose Destination Pattern matches the first few digits of the destination phone number for the call.

If a match is found, the MultiVOIP will manipulate the digits according to the Remove Prefix and Add Prefix fields of the Outbound Phone book entry. The call with the manipulated digits will be routed to the predefined gatekeeper endpoint whose Names entry matches the H.323 ID configured in the Outbound Phone Book entry. This is the normal sequence for calls to FXO trunks.

If there is no match in the Outbound Phone book, the MultiVOIP gatekeeper will try to find a matching number in the Phones field of one of the MultiVOIP gatekeeper predefined endpoints. This is the normal sequence for calls to FXS ports or IP phones.

Suppose the MultiVOIP resides in the 763 exchange of the Minneapolis area with its FXO trunk connected to PSTN lines. This area has an overlayed area code system where calls to 763, 612, 952, and 651 exchanges are all local calls. In this example, we will add Outbound Phone book entries to allow calls to phone numbers within these exchanges as well as 911 calling for emergencies.

8a. Go to the MultiVOIP’s Phone Book | Phone Book Modify | Outbound Phone Book | List Entries screen as seen below.

Multi-Tech Systems MVP103 diagram (page 24)
Fig. 36
Page 25 of the Multi-Tech Systems MVP103 user manual
Page 25 · click to enlarge
Page 25

8b. Click the Add button to add an Outbound Phone Book entry. The Add/Edit Outbound Phone Book screen will be displayed.

Multi-Tech Systems MVP103 diagram (page 25)
Fig. 37

8c. Enter the digit pattern 9763 in the Destination Pattern field. Enter the digit 9 in the Remove Prefix field Enter a description in the Description field for information purposes only. Enable the Use Gatekeeper option and enter Minneapolis-FXO in the Gateway H.323 ID field. The Gateway H.323 ID is essentially a “trunk group name” that matches the Minneapolis-FXO entered in the Names field of the Gatekeeper Predefined Endpoint for the FXO trunk. Note, If your analog trunk line requires that all outgoing calls must dial a “9” or some other access code as part of a CO- Centrex service, you would enter this in the Add Prefix field. Leave the Total Digits and Q.931 Port Number fields set to 0. Leave all other fields blank. Click OK to accept the changes.

Multi-Tech Systems MVP103 diagram (page 25)
Fig. 38
Page 26 of the Multi-Tech Systems MVP103 user manual
Page 26 · click to enlarge
Page 26

8d. Go to the MultiVOIP’s Phone Book | Phone Book Modify | Outbound Phone Book | List Entries screen and click the Add button to add another Outbound Phone Book entry for the 612 area code. Enter the digit pattern of 9612 in the Destination Pattern field. Enter the digit 9 in the Remove Prefix field.

Multi-Tech Systems MVP103 diagram (page 26)
Fig. 39

8e. Add additional Outbound Phone Book entries for calls to the 651 and 952 exchanges as indicated in the screens below:

Multi-Tech Systems MVP103 diagram (page 26)
Fig. 40
Page 27 of the Multi-Tech Systems MVP103 user manual
Page 27 · click to enlarge
Page 27
Multi-Tech Systems MVP103 diagram (page 27)
Fig. 41

8f. Add an Outbound Phone Book entry to handle the routing of 911 emergency calls to the FXO trunk. Since 911 must be dialed out the FXO trunk, leave the Remove Prefix field blank.

Multi-Tech Systems MVP103 diagram (page 27)
Fig. 42
Page 28 of the Multi-Tech Systems MVP103 user manual
Page 28 · click to enlarge
Page 28

8g. The completed Outbound Phone book now includes the entries added in the earlier steps.

Multi-Tech Systems MVP103 diagram (page 28)
Fig. 43

8h. Click on Save Setup | Save and Reboot to save the Outbound Phone Book entries.

9. Dialing examples for gatekeeper survivability mode.

9a. Gatekeeper Survivability dialing example #1: A local station to local IP phone call.

The station at FXS port #1 (6011) goes off hook and receives the survivable dial tone from the MultiVOIP gateway. The client then proceeds to dial 2110.

The MultiVOIP gatekeeper searches the Outbound Phone book for a match to 2110. There is no match.

The MultiVOIP gatekeeper searches the Phones fields of the Predefined Endpoints and finds a match for 2110.

The MultiVOIP gatekeeper routes the call to the IP phone registered with the phone number 2110. When IP phone 2110 answers, the call is completed.

9b. Gatekeeper Survivability dialing example #2: IP phone 2110 dials outward on the local analog trunk to gain access to the local central office.

IP phone 2110 goes off hook and receives survivable dial tone from the MultiVOIP gatekeeper. The client then proceeds to dial 97637174321.

The MultiVOIP gatekeeper searches the Outbound Phone book for a match to 97637174321. It finds a match with Destination Pattern 9763 and Gateway H.323 ID = Minneapolis-FXO. The 9 is removed and the remaining digits 7637174321 remain.

The MultiVOIP gatekeeper searches the Predefined Endpoints for an entry with Minneapolis-FXO in the Names field. It finds a match.

The call with digits 7637174321 is routed to the FXO predefined endpoint registered with Name = Minneapolis-FXO.

The FXO trunk port activates its tip/ring loop-start interface and the digit string “7637174321” is dialed out towards the network.

When the called party of 7637174321 answers, the call is completed.

Page 29 of the Multi-Tech Systems MVP103 user manual
Page 29 · click to enlarge
Page 29

9c. Gatekeeper Survivability dialing example #3: Incoming Central Office call to station 6011. In this case, the Autocall feature has been enabled in the Voice/Fax screen of the MultiVOIP for the FXO trunk channels. The Autocall Phone Number field has been set to 6011.

A call from the Central Office line rings in to the MultiVOIP’s FXO trunk.

The MultiVOIP goes off hook on its FXO tip/ring loop-start interface.

The MultiVOIP automatically place a call to 6011 which has been enabled for autocall in the Voice/Fax screen for the FXO channel.

The MultiVOIP gatekeeper searches the Outbound Phone book for a match to 6011. There is no match.

The MultiVOIP gatekeeper searches the Phones fields of the Predefined Endpoints and finds a match for 6011.

The MultiVOIP gatekeeper routes the call to the FXS station port registered with the phone number 6011. When 6011 answers, the call is completed.

9d. Gatekeeper survivability dialing example number 4: Incoming central office DID call to IP phone 2110. The central office DID line seizes the MultiVOIP DID trunk and dials 2110.

The MultiVOIP gatekeeper searches the Outbound phone book for a match to 2110. There is no match.

The MultiVOIP gatekeeper searches the Phones fields of the predefined Endpoints and finds a match for 2110.

The MultiVOIP gatekeeper routes the call to the IP phone registered with the phone number 2110. When IP phone 2110 answers, the call is completed.

Page 30 of the Multi-Tech Systems MVP103 user manual — Regional Parameters screen
Page 30 · click to enlarge
Page 30

Regional Parameters screen

The main distinguishing feature of the Regional Parameters screen for Avaya Communication Manager MultiVOIPs is the addition of the survivability dial tone.

1. Set the Survivability Tone in the Configuration | Regional Parameters screen.
2. The Regional Parameters screen will appear. For the country selected, the standard set of frequency pairs will be listed for dial tone, busy tone, ‘unobtainable’ tone (fast busy or trunk busy), and ring tone.
Multi-Tech Systems MVP103 — Regional Parameters screen diagram (page 30)
Fig. 44 · Regional Parameters screen
3. In each field, enter the values that fit your particular system. For most applications, it should be sufficient to select the appropriate country/region and leave the settings at their default values.

The Regional Parameters fields are described in the table below.

“Regional Parameter” Definitions Field Name Values Description Country/ Region

Australia, Central America, Chile, Europe, France, USA, Japan, UK, Custom

Name of a country or region that uses a certain set of tone pairs for dial tone, ring tone, busy tone, and ‘unobtainable’ tone (fast busy tone), survivability tone (tone heard briefly, 2 seconds, after going offhook denoting survivable mode of VOIP unit) and re-order tone (a tone pattern indicating the need for the user to hang up the phone). In some cases, the tone-pair scheme denoted by a country name may also be used outside of that country. The “Custom” option (button) assures that any tone- pairing scheme worldwide can be accommodated.

Type column dial tone, ring tone, busy tone, unobtainable tone (fast busy), survivability tone, re-order tone

Type of telephony tone-pair for which frequency, gain, and cadence are being presented.

Frequency 1 freq. in Hertz Lower frequency of pair. Frequency 2 freq. in Hertz Higher frequency of pair.

Gain 1 gain in dB +3dB to –31dB and “mute” setting

Amplification factor of lower frequency of pair. This applies to the dial, ring, busy and ‘unobtainable’ tones that the MultiVOIP outputs as audio to the FXS, FXS, or E&M port. Default: -16dB

Page 31 of the Multi-Tech Systems MVP103 user manual — Regional Parameters screen
Page 31 · click to enlarge
Page 31

“Regional Parameter” Definitions Continued Field Name Values Description Gain 2 gain in dB +3dB to –31dB and “mute” setting

Amplification factor of higher frequency of pair. This applies to the dial, ring, busy, and ‘unobtainable’ (fast busy) tones that the MultiVOIP outputs as audio to the FXS, FXO, or E&M port. Default: -16dB

n/n/n/n four integer time values in milli-seconds; zero value for dial-tone indicates continuous tone

On/off pattern of tone durations used to denote phone ringing, phone busy, connection unobtainable (fast busy), dial tone (“0” indicates continuous tone), survivability, and re-order. Default values differ for different countries/regions. Although most cadences have only two parts (an “on” duration and an “off” duration), some telephony cadences have four parts. Most cadences, then, are expressed as two iterations of a two-part sequence. Although this is redundant, it is necessary to allow for expression of 4-part cadences.

-- Click on the “Custom” button to bring up the Custom Tone Pair Settings screen. (The “Custom” button is active only when “Custom” is selected in the Country/Region field.) This screen allows the user to specify tone pair attributes that are not found in any of the standard national/regional telephony toning schemes.

4. Set Custom Tones and Cadences (optional). . The Regional Parameters dialog box has a secondary dialog box that allows you to customize DTMF tone pairs to create unique ring-tones, dial-tones, busy- tones or “unobtainable” tones (fast busy signal) or “re-order” tones (telling the user that she must hang up an off-hook phone) or “survivability” tones (an indication of call-routing redundancy in Communication Manager systems only) for your system. Regional Parameters can only be adjusted to change tones played on FXS or FXO ports. Tones for IP phones are fixed and cannot be changed.

This screen allows the user to specify tone-pair attributes that are not found in any of the standard national/regional telephony toning schemes. To access this customization feature, click on the Custom button on the Regional Parameters screen. (The “Custom” button is active only when “Custom” is selected in the Country/Region field.)

Multi-Tech Systems MVP103 — Regional Parameters screen diagram (page 31)
Fig. 45 · Regional Parameters screen

Cadence (msec) On/Off · Custom (button)

Page 32 of the Multi-Tech Systems MVP103 user manual — Custom Tone-Pair Settings Definitions
Page 32 · click to enlarge
Page 32

The Custom Tone-Pair Settings fields are described in the table below.

Custom Tone-Pair Settings Definitions

Field Name Values Description

Tone Pair dial tone, busy tone, ring tone, ‘unobtainable’ tone, survivability tone, re-order tone

Identifies the type of telephony signaling tone for which frequencies are being specified.

TONE PAIR VALUES About Defaults: US telephony values are used as defaults on this screen. However, since this dialog box is provided to allow custom tone-pair settings, default values are essentially irrelevant.

Frequency 1 frequency in Hertz Frequency of lower tone of pair. This outbound tone pair enters the MultiVOIP at the input port.

Frequency 2 frequency in Hertz Frequency of higher tone of pair. This outbound tone pair enters the MultiVOIP at the input port.

Gain 1 gain in dB +3dB to –31dB and “mute” setting

Amplification factor of lower frequency of pair. This figure describes amplification that the MultiVOIP applies to outbound tones entering the MultiVOIP at the input port. Default = -16dB Gain 2 gain in dB +3dB to –31dB and “mute” setting

Amplification factor of higher frequency of pair. This figure describes amplification that the MultiVOIP applies to outbound tones entering the MultiVOIP at the input port. Default = -16dB

Cadence 1 integer time value in milli-seconds; zero value for dial-tone indicates continuous tone

On/off pattern of tone durations used to denote phone ringing, phone busy, dial tone (“0” indicates continuous tone) survivability and re-order. Cadence 1 is duration of first period of tone being “on” in the cadence of the telephony signal (which could be ring-tone, busy-tone, unobtainable-tone, or dial-tone).

Cadence 2 duration in milliseconds Cadence 2 is duration of first “off” period in signaling cadence.

Cadence 3 duration in milliseconds Cadence 3 is duration of second “on” period in signaling cadence.

Cadence 4 duration in milliseconds Cadence 4 is duration of second “off” period in the signaling cadence, after which the 4-part cadence pattern of the telephony signal repeats.

Page 33 of the Multi-Tech Systems MVP103 user manual — Communication Manager Parameter Definitions
Page 33 · click to enlarge
Page 33

For your convenience, the Communication Manager Settings, MultiVOIP Voice/Fax, Interface, and Gatekeeper parameters are detailed in this section.

Communication Manager Settings

In the Communication Manager Settings screen, if the “Register with Communication Manager Gatekeeper option is selected, then many of the parameters must assume default values and those will be grayed on the screen.

Multi-Tech Systems MVP103 — Communication Manager Settings diagram (page 33)
Fig. 46 · Communication Manager Settings

The Communication Manager Parameter fields are described in the table below.

Communication Manager Parameter Definitions

Field Name Values Description

Select Channel Channel n Denotes the VOIP channel to which settings in the current screen apply.

“Interface Type is …”

FXS Loop Start; FXO; DID

Indicates the telephony interface used on the selected VOIP channel.

Page 34 of the Multi-Tech Systems MVP103 user manual — Field Name Values Description
Page 34 · click to enlarge
Page 34

Communication Manager Parameter Definitions Continued

Field Name Values Description

Q.931 Parameters

Use Fast Start Y/N Enables the H.323 Fast Start procedure. If “Register with

Communication Manager Gatekeeper” is enabled, this field defaults to “N” and cannot be changed.

port number This value must be unique for each of the MultiVOIP’s FXS ports. This value must be the same for all of the MultiVOIP unit’s FXO/DID ports that are managed by CM.

in milliseconds Applicable to FXO ports only. It indicates the amount of delay that will be introduced before a dialed sequence is sent.

alpha-numeric string Optional. The name of the GateKeeper with which this MultiVOIP is trying to register. Gateway Prefix

If “Register with Communication Manager Gatekeeper” is enabled, this field is not used. This number becomes registered with the GateKeeper. Call requests sent to the gatekeeper and preceded by this prefix will be routed to the VOIP gateway.

Gateway H.323 ID

The H.323 ID is used to register FXO trunks with the MultiVOIP GateKeeper.

numeric This phone number (PBX extension) must match the extension configured on the Communication Manager “station” form (dialog box). It is only relevant for the MultiVOIP’s FXS channels.

Security Code alpha-numeric This field value must match the security code configured on the Communication Manager “station” form (dialog box). It is only relevant for the MultiVOIP’s FXS channels.

Default Applies default values to all fields in the Communication Manager Parameters screen.

Unregister Allows you to unregister the registered station or trunk with respect to the Communication Manager Gatekeeper. This command has an immediate effect. This is a very useful diagnostic command. Register Allows you to register the unregistered station or trunk with respect to the Communication Manager Gatekeeper. This command has an immediate effect. This is a very useful diagnostic command. Columns

The IP address of the Communication Manager Gatekeeper.

RAS Port Typically this is 1719.

This field must be left blank

One PBX in the system must serve as the primary gatekeeper.

Alternate GK 1 It is optional for the system to have a PBX that serves as a first alternate gatekeeper. Alternate GK 2 It is optional for the system to have a PBX that servers as a second alternate gatekeeper.

Show 10 more labels / short text on this page
Call Signaling Port · Delay Before Dial · GateKeeper RAS Parameters · Gatekeeper Name · Phone Number/ Extension · Buttons · GateKeeper IP Address · GateKeeper Name · Rows · Primary [gatekeeper]
Page 35 of the Multi-Tech Systems MVP103 user manual — Communication Manager Settings
Page 35 · click to enlarge
Page 35

Communication Manager Parameter Definitions (cont’d) Field Name Values Description

RAS Time to Live

The MultiVOIP sends this value to CM in the Registration Request (RRQ). However, the MultiVOIP will send “Keepalive” RRQs based on the TTL received from CM during Registration Confirm (RCF) Enable Survivability Mode

Y/N Enable/disable MultiVOIP’s Gateway Survivable mode wherein MultiVOIP manages its own IP traffic using its inbound and outbound phonebooks in the event of failure of the primary, alternate #1 and #2 gatekeepers (if alternates are present). Switching Time Interval

When MultiVOIP is in “gateway” survivable mode meaning the Communication Manager gatekeeper to which it is registered failed (along with any alternate gatekeepers providing redundancy), the MultiVOIP manages IP phone traffic with its own phonebooks. It will seek to return to being controlled by the Communication Manager gatekeeper. The Switching Time Interval determines how often it will seek to restore its registration with the primary Communication Manager gatekeeper. H.323 Version 4 Parameters Q.931 Multiplexing (Mux)

Y/N Signaling for multiple phone calls can be carried on a single port rather than opening a separate signaling port for each call. This conserves bandwidth resources. If “Register with Communication Manager Gatekeeper” is enabled, this field defaults to “Y” for FXO/DID ports and to “N” for FXS ports and it cannot be changed.

H.245 Tunneling (Tun)

Y/N H.245 messages are encapsulated within the Q.931 call-signaling channel. Among other things, the H.245 messages let the two endpoints tell each other what their technical capabilities are and determine who, during the call, will be the client and who the server. Tunneling is the process of transmitting these H.245 messages through the Q.931 channel. The same TCP/IP socket (or logical port) already being used for the Call Signaling Channel is then also used by the H.245 Control Channel. This encapsulation reduces the number of logical ports (sockets) needed and reduces call setup time. If “Register with Communication Manager Gatekeeper” is enabled, this field defaults to “Y” for FXS and FXO ports and cannot be changed.

H.323 Version 4 Parameters Parallel H.245 (FS + Tun)

Y/N FS (Fast Start or Fast Connect) is a Q.931 feature of H.323v2 to hasten call setup as well as ‘pre-opening’ the media channel before the CONNECT message is sent. This pre-opening is a requirement for certain billing activities. Under Parallel H.245 FS + Tun, this Fast Connect feature can operate simultaneously with H.245 Tunneling (see description above). If “Register with Communication Manager Gatekeeper” is enabled, this field defaults to “N” for FXS and FXO ports and cannot be changed. Annex –E (AE) Y/N Multiplexed UDP call signaling transport. Annex E is helpful for high-volumeVOIP system endpoints. Gateways with lesser volume can afford to use TCP to establish calls. However, for larger volume endpoints, the call setup times and system resource usage under TCP can become problematic. Annex E allows endpoints to perform call- signaling functions under the UDP protocol, which involves substantially streamlined overhead. (This feature should not be used on the public Internet because of potential problems with security and bandwidth usage.) If “Register with Communication Manager Gatekeeper” is enabled, this field defaults to “N” for FXS and FXO ports and cannot be changed.

Numeric (in seconds) · numeric (in seconds)

Page 36 of the Multi-Tech Systems MVP103 user manual — Voice/Fax Parameters
Page 36 · click to enlarge
Page 36

Voice/Fax Parameters

In each field, enter the values that fit your particular network.

Multi-Tech Systems MVP103 — Voice/Fax Parameters diagram (page 36)
Fig. 47 · Voice/Fax Parameters
Page 37 of the Multi-Tech Systems MVP103 user manual — Voice/Fax Parameters
Page 37 · click to enlarge
Page 37

Note that Voice/FAX parameters are applied on a channel-by-channel basis. However, once you have established a set of Voice/FAX parameters for a particular channel, you can apply this entire set of Voice/FAX parameters to another channel by using the Copy Channel button and its dialog box. To copy a set of Voice/FAX parameters to all channels, select “Copy to All” and click Copy.

Multi-Tech Systems MVP103 — Voice/Fax Parameters diagram (page 37)
Fig. 48 · Voice/Fax Parameters

The Voice/FAX Parameters fields are described in the tables below.

Voice/Fax Parameter Definitions Field Name Values Description Default -- When this button is clicked, all Voice/FAX parameters are set to their default values. Select Channel

1-2 (210) 1-4 (410) 1-8 (810) Channel to be configured is selected here.

-- Copies the Voice/FAX attributes of one channel to another channel. Attributes can be copied to multiple channels or all channels at once. Voice Gain -- Signal amplification (or attenuation) in dB. Input Gain +31dB to –31dB Modifies audio level entering voice channel before it is sent over the network to the remote VOIP. The default & recommended value is 0 dB. Output Gain +31dB to –31dB Modifies audio level being output to the device attached to the voice channel. The default and recommended value is 0 dB.

Copy Channel

Page 38 of the Multi-Tech Systems MVP103 user manual — Voice/Fax Parameter Definitions Continued
Page 38 · click to enlarge
Page 38

Voice/Fax Parameter Definitions Continued

Field Name Values Description DTMF Parameters

DTMF Gain -- The DTMF Gain (Dual Tone Multi-Frequency) controls the volume level of the DTMF tones sent out for Touch- Tone dialing. DTMF Gain, High Tones

Default value: -4 dB. Not to be changed except under supervision of MultiTech’s Technical Support. DTMF Gain, Low Tones

+3dB to -31dB & “mute”

Default value: -7 dB. Not to be changed except under supervision of MultiTech’s Technical Support. Duration (DTMF)

+3dB to -31dB & “mute”

60. 3000 ms When DTMF: Out of Band is selected, this setting determines how long each DTMF digit ‘sounds’ or is held. Default = 100 ms. DTMF In/Out of Band

Out of Band, or Inband When DTMF Out of Band is selected, the MultiVOIP detects DTMF tones at its input and regenerates them at its output. When DTMF Inband is selected, the DTMF digits are passed through the MultiVOIP unit as they are received.

FAX Parameters Fax Enable Y/N Enables or disables fax capability for a particular channel. Max Baud Rate (Fax)

2400, 4800, 7200, 9600, 12000, 14400 bps Set to match baud rate of fax machine connected to channel (see Fax machine’s user manual). For CM managed fax calls it is recommended to use 9600. Default = 14400 bps. Fax Volume (Default = -9.5 dB )

-18.5 dB to –3.5 dB

Controls output level of fax tones. To be changed only under the direction of Multi-Tech’s Technical Support.

Default = 400 ms Defines the inter-arrival packet deviation (in milliseconds) for the fax transmission. A higher value will increase the delay, allowing a higher percentage of packets to be reassembled. A lower value will decrease the delay allowing fewer packets to be reassembled. Mode (Fax) FRF 11; T.38

FRF11 is frame-relay FAX standard using these coders: G.711, G.728,

G.729, G.723.1. T.38 is an ITU-T standard for storing and forwarding FAXes via email using X.25 packets. It uses T.30 fax standards and includes special provisions to preclude FAX timeouts during IP transmissions. Must use T.38 when faxing to/from CM.

Determines whether selection of coder is manual or automatic. Must be set to manual for CM managed calls. When Automatic is selected, the local and remote voice channels will negotiate the voice coder to be used by selecting the highest bandwidth coder supported by both sides without exceeding the Max Bandwidth setting. G.723, G.729, or G.711 are negotiated.

Jitter Value (Fax)

Page 39 of the Multi-Tech Systems MVP103 user manual — Field Name Values Description Coder Parameters (cont’d)
Page 39 · click to enlarge
Page 39

Voice/Fax Parameter Definitions Continued

Field Name Values Description Coder Parameters (cont’d)

G.711 a/u law 64 kbps; G.726, @ 16/24/32/40 kbps; G.727, @ nine bps rates; G.723.1 @ 5.3 kbps, 6.3 kbps; G.729, 8kbps; Net Coder @ 6.4, 7.2, 8, 8.8, 9.6 kbps G.711/G.729 G.729/G.711

Select from a range of coders with specific bandwidths. The higher the bps rate, the more bandwidth is used. The channel that you are calling must have the same voice coder selected. Default = G.723.1 @ 6.3 kbps, as required for H.323. Here 64K of digital voice are compressed to 6.3K, allowing several simultaneous conversations over the same bandwidth that would otherwise carry only one. To make selections from the Selected Coder drop-down list, the Manual option must be enabled.

This drop-down list enables you to select the maximum bandwidth allowed for this channel. The Max Bandwidth drop-down list is enabled only if the Coder is set to Automatic. If coder is to be selected automatically (“Auto” setting), then enter a value for maximum bandwidth. Advanced Features

11. 128 kbps

Y/N Determines whether silence compression is enabled (checked) for this voice channel.

With Silence Compression enabled, the MultiVOIP will not transmit voice packets when silence is detected, thereby reducing the amount of network bandwidth that is being used by the voice channel. Default = off.

Y/N Determines whether echo cancellation is enabled (checked) for this voice channel.

Echo Cancellation removes echo and improves sound quality. Default = on.

Y/N Determines whether forward error correction is enabled (checked) for this voice channel. Forward Error Correction enables some of the voice packets that were corrupted or lost to be recovered. FEC adds an additional 50% overhead to the total network bandwidth consumed by the voice channel. Default = Off

Show 5 more labels / short text on this page
Selected Coder · Max bandwidth (coder) · Silence Compression · Echo Cancellation · Forward Error Correction
Page 40 of the Multi-Tech Systems MVP103 user manual — Dynamic Jitter
Page 40 · click to enlarge
Page 40

Voice/Fax Parameter Definitions Continued Field Name

Values Description

Auto Call / Offhook Alert

The AutoCall option enables the local MultiVOIP to place a call without the user having to dial a number. As soon as you access the local MultiVOIP voice/fax channel, the MultiVOIP immediately connects to the remote endpoint identified in the Phone Number box of this option.

If the “Pass Through Enable” field is checked in the Interface Parameters screen, AutoCall must be used.

The Offhook Alert option applies only to FXS channels.

The Offhook Alert option works like this: if a phone goes offhook and no number is dialed within a specific period of time (as set in the Offhook Alert Timer field), then that phone will automatically dial the Alert phone number for the voip channel. (The Alert phone number must be set in the Voice/Fax Parameters | Phone Number field). One use of this feature would be for emergency use where a user goes off hook but does not dial, possibly indicating a crisis situation. The Offhook Alert feature uses the Intercept Tone, as listed in the Regional Parameters screen. This tone will be output on the phone that was taken off hook but that did not dial. The other end of the connection will hear audio from the “crisis” end as it would during a normal phone call.

Both functions apply on a channel-by-channel basis. It would not be appropriate for either of these functions to be applied to a channel that serves in a pool of available channels for general phone traffic.

Generate Local Dial Tone

Y/N Used for AutoCall only. If selected, dial tone will be generated locally while the call is being established between gateways. The capability to generate dial tone locally would be particularly useful when there is a lengthy network delay.

0. 3000 seconds

The length of time that must elapse before the offhook alert is triggered and a call is automatically made to the phone number listed in the Phone Number field.

-- Phone number used for Auto Call function or Offhook Alert Timer function.

Dynamic Jitter

Dynamic Jitter defines a minimum and a maximum jitter value for voice communications. When receiving voice packets from a remote MultiVOIP, varying delays between packets may occur due to network traffic problems. This is called Jitter. To compensate, the MultiVOIP uses a Dynamic Jitter Buffer. The Jitter Buffer enables the MultiVOIP to wait for delayed voice packets by automatically adjusting the length of the Jitter Buffer between configurable minimum and maximum values. An Optimization Factor adjustment controls how quickly the length of the Jitter Buffer is increased when jitter increases on the network. The length of the jitter buffer directly effects the voice delay between MultiVOIP gateways.

Show 5 more labels / short text on this page
AutoCall/Offhook Alert Parameters · AutoCall, Offhook Alert · Offhook Alert Timer · Phone Number · Dynamic Jitter Buffer
Page 41 of the Multi-Tech Systems MVP103 user manual — Auto Disconnect
Page 41 · click to enlarge
Page 41

Voice/Fax Parameter Definitions (cont’d)

Field Name Values Description

Dynamic Jitter (cont’d)

60 to 400 ms The minimum dynamic jitter buffer of 60 milliseconds is the minimum delay that would be acceptable over a low jitter network. Default = 150 msec Maximum Jitter Value

60 to 400 ms The maximum dynamic jitter buffer of 400 milliseconds is the maximum delay tolerable over a high jitter network. Default = 300 msec

0 to 12 The Optimization Factor determines how quickly the length of the Dynamic Jitter Buffer is changed based on actural jitter encountered on the network. Selecting the minimum value of 0 means low voice delay is desired, but increases the possibility of jitter induced voice quality problems. Selecting the maximum value of 12 means highest voice qauality under jitter conditions is desired at the cost of increased voice delay. Default = 7.

Auto Disconnect

-- The Automatic Disconnection group provides four options which can be used singly or in any combination.

Jitter Value 1-65535 milli-seconds

The Jitter Value defines the average inter-arrival packet deviation (in milliseconds) before the call is automatically disconnected. The default is 300 milliseconds. A higher value means voice transmission will be more accepting of jitter. A lower value is less tolerant of jitter. Inactive by default. When active, default = 300 ms. However, value must equal or exceed Dynamic Minimum Jitter Value.

Call Duration 1-65535 seconds Call Duration defines the maximum length of time (in seconds) that a call remains connected before the call is automatically disconnected. Inactive by default. When active, default = 180 sec. This may be too short for most configurations, requiring upward adjustment.

1-65535 Consecutive Packets Lost defines the number of consecutive packets that are lost after which the call is automatically disconnected. Inactive by default. When active, default = 30

1 to 65535 seconds; Default = 30 sec.

Specifies how long to wait before disconnecting the call when IP network connectivity with the remote site has been lost.

Show 5 more labels / short text on this page
Minimum Jitter Value · Optimization Factor · Automatic Disconnect- ion · Consecutive Packets Lost · Network Discon- nection
Page 42 of the Multi-Tech Systems MVP103 user manual — Interface Parameters
Page 42 · click to enlarge
Page 42

Interface Parameters

In each field, enter the values that fit your particular network.

Multi-Tech Systems MVP103 — Interface Parameters diagram (page 42)
Fig. 49 · Interface Parameters
Page 43 of the Multi-Tech Systems MVP103 user manual — Interface Parameters
Page 43 · click to enlarge
Page 43

The kinds of parameters for which values must be chosen depend on the type of telephony supervisory signaling or interface used (FXO, E&M, etc.). We present here the various parameters grouped and organized by interface type.

Note that Interface parameters are applied on a channel-by-channel basis. However, once you have established a set of Interface parameters for a particular channel, you can apply this entire set of Voice/FAX parameters to another channel by using the Copy Channel button and its dialog box. To copy a set of Interface parameters to all channels, select “Copy to All” and click Copy.

Multi-Tech Systems MVP103 — Interface Parameters diagram (page 43)
Fig. 50 · Interface Parameters
Page 44 of the Multi-Tech Systems MVP103 user manual — FXS Loop Start Interface: Parameter Definitions Field Name Values Description
Page 44 · click to enlarge
Page 44

FXS Loop Start Parameters. The parameters applicable to FXS Loop Start are shown in the figure below and described in the table that follows.

Multi-Tech Systems MVP103 — Interface Parameters diagram (page 44)
Fig. 51 · Interface Parameters

FXS Loop Start Interface: Parameter Definitions Field Name Values Description

Y/N Enables FXS Loop Start interface type.

1. 10 seconds This is the length of time that the MultiVOIP will wait between digits. When the time expires, the MultiVOIP will place the call.

Default = 2.

-- If “Register with Communication is enabled”, this field enables message waiting indication on FXS channels. Choices are “Light” or “Stutter Dial Tone”.

Inter Digit Regeneration Time

The length of time between the outputting of DTMF digits. Default = 100 ms.

1-99 Maximum number of rings that the MultiVOIP will issue before giving up the attempted call.

Y/N When enabled, the MultiVOIP will interrupt loop current in the FXS circuit to initiate a disconnection. This tells the device connected to the FXS port to hang up. The Multi-VOIP cannot drop the call; the FXS device must go on hook.

FXS Options, Current Loss

Show 6 more labels / short text on this page
FXS (Loop Start) · Dialing Options fields · Inter Digit Timer · Message Waiting Indication · in milliseconds · Ring Count, FXS
Page 45 of the Multi-Tech Systems MVP103 user manual — FXS Loop Start Interface: Parameter Definitions (cont’d) Field Name Values Description
Page 45 · click to enlarge
Page 45

FXS Loop Start Interface: Parameter Definitions (cont’d) Field Name Values Description

Flash Hook Options fields

Generation -- not applicable to FXS interface

for Min. and Max., 50 - 1500 milliseconds

For a received flash hook to be regarded as such by the MultiVOIP, its duration must fall between the minimum and maximum values given here.

Y/N Not used if “Register with Communication Manager” is enabled

Caller ID Type Bellcore The MultiVOIP currently supports only one implementation of Caller ID. That implementation is Bellcore type 1 with Caller ID placed between the first and second rings of the call. Caller ID enable

Y/N Caller ID information is a description of the remote calling party received by the called party. The description has three parts: name of caller, phone number of caller, and time of call. The ‘time-of-call’ portion is always generated by the receiving MultiVOIP unit (on FXS channel) based on its date and time setup. Caller ID enable (cont’d)

Y/N The forms of the ‘Caller Name’ and ‘Caller Phone Number’ differ depending on the IP transmission protocol used (H.323, SIP, or SPP) and upon entries in the phonebook screens of the remote (CID generating) voip unit. The CID Name and Number appearing on the phone at the terminating FXS end will come either from a central office switch (showing a PSTN phone number), or the phonebook of the remote (CID sending) voip unit.

The Caller ID feature has dependencies on both the telco central office and the MultiVOIP phone book. See discussion after the FXO Parameters section below.

Detection Range · Pass Through Enable · Caller ID fields

Page 46 of the Multi-Tech Systems MVP103 user manual — FXO Interface: Parameter Definitions
Page 46 · click to enlarge
Page 46

FXO Parameters. The parameters applicable to the FXO telephony interface type are shown in the figure below and described in the table that follows.

Multi-Tech Systems MVP103 — Interface Parameters diagram (page 46)
Fig. 52 · Interface Parameters

FXO Interface: Parameter Definitions

Field Name Values Description

Interface, FXO Y/N Enables FXO functionality

Regeneration Pulse, DTMF Determines whether digits generated and sent out will be pulse tones or DTMF.

-- Not applicable to FXO interface.

Inter Digit Regeneration Time

50 to 20,000 milliseconds

The length of time between the outputting of DTMF digits. Default = 100 ms.

There are three possible criteria for disconnection under FXO: current loss, tone detection, and silence detection. Disconnection can be triggered by more than one of the three criteria.

Current Loss Y/N Disconnection to be triggered by loss of current. That is, when Current Loss is enabled (“Y”), the MultiVOIP will hang up the call when it detects a loss of current initiated by the attached device.

Current Loss Detect Timer

integer values (in milliseconds )

The minimum time required for detecting the current loss signal on the FXO interface. In other words, this is the minimum length of time the current must be absent to validate ‘current loss’ as a disconnection criterion. Default = 500 ms.

Tone Detection Y/N Disconnection to be triggered by a tone sequence.

Dialing Options · Message Waiting Indication · FXO Disconnect On

Page 47 of the Multi-Tech Systems MVP103 user manual — A B C D
Page 47 · click to enlarge
Page 47
FXO InterfaceParameter Definitions (cont’d)

Field Name Values Description

FXO Disconnect On (cont’d)

1 st tone pair + 2 nd tone pair

These are DTMF tone pairs.

Values for first tone pair are: *, #, 0, 1-9, and A-D.

Values for second tone pair are: none, 0, 1-9, A-D, *, and #. The tone pairs 1-9, 0, *, and # are the standard DTMF pairs found on phone sets. The tone pairs A-D are “extended DTMF” tones, which are used for various PBX functions.

Low Tones 697Hz 770Hz 852Hz 941Hz High Tones 1209Hz 1336Hz 1447Hz 1633Hz

1 4 7 *

2 5 8 0

3 6 9 #

A B C D

Disconnection to be triggered by silence in one direction only or in both directions simultaneously.

Silence Timer in seconds

integer value Duration of silence required to trigger disconnection.

Disconnect on Call Progress Tone

Y/N Allows call on FXO port to be disconnected when a PBX issues a call- progress tone denoting that the phone station on the PBX that has been involved in the call has been hung up.

Ring Count, FXO

1-99 Number of rings required before the MultiVOIP answers the incoming call.

Flash Hook Options fields

Generation 50 - 1500 milliseconds

Length of flash hook that will be generated and sent out when the remote end initiates a flash hook and it is regenerated locally. Default = 600 ms.

-- Not applicable to FXO.

Caller ID Type Bellcore The MultiVOIP currently supports only one implementation of Caller ID. That implementation is Bellcore type 1 with caller ID placed between the first and second rings of the call. Caller ID enable

Y/N Caller ID information is a description of the remote calling party received by the called party. The description has three parts: name of caller, phone number of caller, and time of call. The ‘time-of-call’ portion is always generated by the receiving MultiVOIP unit (on FXS channel) based on its date and time setup. The forms of the ‘Caller Name’ and ‘Caller Phone Number’ differ depending on the IP transmission protocol used (H.323, SIP, or SPP) and upon entries in the phonebook screens of the remote (CID generating) voip unit. The CID Name and Number appearing on the phone at the terminating FXS end will come either from a central office switch (showing a PSTN phone number), or the phonebook of the remote (CID sending) voip unit.

The Caller ID feature has dependencies on both the telco central office and the MultiVOIP phone book. See discussion below.

Show 6 more labels / short text on this page
Disconnect Tone Sequence · DTMF Tone Pairs · Silence Detection · One-Way or Two-Way · Detection Range · Caller ID fields
Page 48 of the Multi-Tech Systems MVP103 user manual — enters SPP voip system
Page 48 · click to enlarge
Page 48
Multi-Tech Systems MVP103 — Interface Parameters diagram (page 48)
Fig. 53 · Interface Parameters
CID Number763-555-8794 CID Name: Melvin Jones Time Stamp: Date: 05/31 Time:1:42pm

In x.06 release, when SIP protocol is used, CID Name field will duplicate value in CID Number field. *

Figure 1: Voip Caller ID Case #1 – Call, through telco central office with standard CID, enters

voip system

Multi-Tech Systems MVP103 — voip system diagram (page 48)
Fig. 54 · voip system
CID Number423 CID Name: Anoka-Whse-VP3 Time Stamp: Date: 7/10 Time: 4:19pm

In x.06 release, when SIP protocol is used, CID Name field will duplicate value in CID Number field.

Figure 2Voip Caller ID Case #2 – Call, through telco central office without standard CID,

enters H.323 voip system

Multi-Tech Systems MVP103 — enters H.323 voip system diagram (page 48)
Fig. 55 · enters H.323 voip system

xx xyy yz zz z J.Q. Public x xxy yy zz zz J.Q. Public

CID Number423 CID Name: Shipping Dept Time Stamp: Date: 0927 Time: 1747

... if “Description” field in Add/Edit Inbound Phone Book is used

CID Number423 CID Name: Anoka-Whse-VP3 Time Stamp: Date: 0927 Time: 1747

... if “Description” in Add/Edit Inbound Phone Book is blank

Figure 3Voip Caller ID Case #3 – Call, through telco central office without standard CID,

enters SPP voip system

Page 49 of the Multi-Tech Systems MVP103 user manual — DID channel in H.323 voip system
Page 49 · click to enlarge
Page 49
Multi-Tech Systems MVP103 — Interface Parameters diagram (page 49)
Fig. 56 · Interface Parameters
CID Number423 CID Name: Anoka-Whse-VP3 Time Stamp: Date: 10/03 Time: 4:51pm

In x.06 release, when SIP protocol is used, CID Name field will duplicate value in CID Number field.

Figure 4Voip Caller ID Case #4 – Remote FXS call on H.323 voip system
Multi-Tech Systems MVP103 — Interface Parameters diagram (page 49)
Fig. 57 · Interface Parameters
CID Number423 CID Name: Anoka-Whse-VP3 Time Stamp: Date: 11/15 Time: 6:17pm

In x.06 release, when SIP protocol is used, CID Name field will duplicate value in CID Number field.

Figure 5: Voip Caller ID Case #5 – Call through telco central office without standard CID enters

DID channel in H.323 voip system

E&M Parameters. E&M is not supported if “Register with Communication Manager” is enabled.

DID Parameters. The parameters applicable to the Direct Inward Dial (DID) telephony interface type are shown in the figure below and described in the table that follows. The DID interface allows one phone line to direct incoming calls to any one of several extensions without a switchboard operator. Of course, one DID line can handle only one call at a time. The parameters described here pertain to the customer- premises side of the DID connection (DID-DPO, dial-pulse originating); the network side of the DID connection (DID-DPT, dial-pulse terminating) is not supported.

Multi-Tech Systems MVP103 — DID channel in H.323 voip system diagram (page 49)
Fig. 58 · DID channel in H.323 voip system
Page 50 of the Multi-Tech Systems MVP103 user manual — DID Interface Parameter Definitions
Page 50 · click to enlarge
Page 50

DID Interface Parameter Definitions

Field Name Values Description

Interface DID-DPO Enables the customer-premises side of DID functionality

DID Options MultiVOIP’s use of DID applies only for incoming DID calls. The Start Mode used by the MultiVOIP must match that used by the originating telephony equipment, else DID calls cannot be completed.

For Immediate Start, the voip detects the off-hook condition initiated by the telco central-office call and becomes ready to receive dial digits immediately.

Start Modes Immediate Start, Wink Start, Delay Dial

For Wink Start, the voip detects the off-hook condition. Then the voip reverses battery polarity for a specified time (140-290 ms; a “wink”) and then becomes ready to receive dial digits.

For Delay Dial, the voip detects detects the off-hook condition. Then the voip reverses battery polarity for a specified time (reverse polarity duration has wider acceptable range than for Wink Start) and then becomes ready to receive dial digits.

Wink Timer (in ms)

integer values, in milliseconds

This is the length of the wink for Wink Start and Delay Dial signaling modes..

Applicable only when Start Mode parameter is set to “Wink Start” or “Delay Dial.”

integer values, in seconds

This is the length of time that the MultiVOIP will wait between digits. When the time expires, the MultiVOIP will look in the phonebook for the number entered.

Default = 2.

-- Not applicable to DID-DPO interface.

This parameter is applicable when digits are dialed onto a DID-DPO channel after the connection has been made. The length of time between the outputting of DTMF digits. Default = 100 ms.

integer values, in milliseconds

Show 4 more labels / short text on this page
Dialing Options · Inter Digit Timer · Message Waiting Indication · Inter-Digit Regeneration Timer
Page 51 of the Multi-Tech Systems MVP103 user manual — GK General Settings Definitions Field Name Values Description Registration Policy
Page 51 · click to enlarge
Page 51

GK General Settings

The fields in the main gatekeeper screen, the GK General Settings screen, must be configured as shown below.

Multi-Tech Systems MVP103 — GK General Settings diagram (page 51)
Fig. 59 · GK General Settings

GK General Settings Definitions Field Name Values Description Registration Policy

No Endpoints Y/N When selected, sets a policy whereby the Gatekeeper accepts no registrations.

Y/N When selected, sets a strict zone policy, in which the Gatekeeper accepts only registrations that arrive from predefined endpoints. A strict zone policy controls network resources and services more tightly than an open zone policy.

Y/N When selected, sets an open zone policy, in which the Gatekeeper accepts any legal

registration. Under this policy, the Gatekeeper can operate in “plug-and-play” mode.

Y/N When checked, the voip unit will accept calls.

GK Active Y/N When checked, the voip unit’s gatekeeper function is active.

Debug Level 0-100 The higher the value, the greater the details in Syslog or Console reports.

Launches secondary screen on Memory issues. (See next table.)

Show 6 more labels / short text on this page
Predefined Endpoints · All Endpoints · Activity Configuration · Accepts Calls · Buttons · Memory Settings
Page 52 of the Multi-Tech Systems MVP103 user manual — GK General Settings
Page 52 · click to enlarge
Page 52

Click on the Memory Setting button to access the Memory screen. The configurable fields must be configured as shown below.

Multi-Tech Systems MVP103 — GK General Settings diagram (page 52)
Fig. 60 · GK General Settings

GK General Settings Definitions (cont’d) Field Name Values Description GK Memory Values

10, 20, 30 The maximum number of concurrent calls. MVP210AV support 5 calls; MVP410 AV supports 10 calls; MVP810 AV supports 15 calls.

2. 250 Maximum number of endpoints that can be registered on the gatekeeper-controlled network. Note: IP phones registrations are limited to 15 regardless of this setting.

RAS Parameters In H.323, RAS parameters pertain to Registration, Admission, and Status in the H.225 Call Signaling Protocol.

The timeout (in seconds) before re-transmission of a RAS message that had previously fetched no response.

RAS Port The RAS port for gatekeeper communication with endpoints. Default value = 1719

Q.931 Parameters In H.323, Q.931 parameters are those that pertain to the set-up and tear- down of connections between H.323 endpoints.

The timeout (in seconds) waiting for the TCP reply.

The timeout (in seconds) waiting for the Connect message of a call.

Q.931 Signaling Port

Logical port through which Q.931 protocol messages are handled. Default value = 1730

Default Invokes default values for all parameters on the GK General Settings screen.

Show 6 more labels / short text on this page
Maximum Calls · Maximum Registrations · Response TO · Response TO (sec) · Connect TO (sec) · Buttons
Page 53 of the Multi-Tech Systems MVP103 user manual — Gatekeeper – Endpoints
Page 53 · click to enlarge
Page 53

Gatekeeper – Endpoints

When an endpoint registers with the gatekeeper, the endpoint is activated. That is, it becomes an acknowledged participant on the network (or on a particular zone of a network). Registration tells the gatekeeper that the endpoint is active and ready to receive calls. An endpoint’s registration can be static (essentially permanent) or dynamic (timed or conditional).

The fields of the Existing Endpoints screen are described in the table below.

Multi-Tech Systems MVP103 — Gatekeeper – Endpoints diagram (page 53)
Fig. 61 · Gatekeeper – Endpoints
Multi-Tech Systems MVP103 — Gatekeeper – Endpoints diagram (page 53)
Fig. 62 · Gatekeeper – Endpoints
Page 54 of the Multi-Tech Systems MVP103 user manual — MCU,
Page 54 · click to enlarge
Page 54

Existing Endpoints Parameter Definitions Field Name Values Description Type Gatekeeper,

The endpoint type . When an endpoint attempts to register with the Gatekeeper, the Gatekeeper compares the endpoint type with the predefined value. If the Gatekeeper detects a discrepancy, the registration is not accepted. If you are not sure of the endpoint type, select Undefined, which allows any endpoint of any type to register with the Gatekeeper. (Multipoint Control Units, MCUs, are used to facilitate conference calls.)

MCU,

Undefined.

When “+” appears, the endpoint’s registration is dynamic or “online.”

When “+” appears, the endpoint’s registration is static or “predefined.”

n.n.n.n 0-255 The RAS address and RAS port of the endpoint.

Name The H.323 ID alias of the endpoint.

Phone The e164 alias number (conventional PSTN phone number)of the endpoint.

Additional aliases for the endpoint: URL, e-mail address, transport address, party.address, or private network number (per ISO/IEC 11571). Alias addresses must be unique within a zone. Gatekeepers themselves cannot have aliases. Msg LRQ, RRQ, URQ, or

The type of message sent by the endpoint when the mode for processing registration is manual. This can be an LRQ, RRQ, URQ, or AppURQ (which is a URQ sent by the Gatekeeper).).).

TTL seconds The time remaining in seconds before the TimeToLive timer expires. If the endpoint fails to reregister within this time, the endpoint is unregistered. Command Buttons

Add -- Opens an empty Predefined Properties dialog box where you can predefine a new registration.

Unregister -- Sends a URQ message to the selected endpoint, deleting the online (or dynamic) registration properties and unregistering the endpoint.

-- Sends a URQ to all the online endpoints in order to unregister them.

-- Disconnects all calls with which the endpoint is involved.

Delete -- Deletes the endpoint from the Gatekeeper database. A URQ will not be sent to the endpoint.

Del Pre-def -- Deletes the predefined (static) properties of the endpoint.

-- Opens the Online properties screen or the selected endpoint whereupon are shown details of that endpoint’s configuration.

Show 15 more labels / short text on this page
Gateway, · Terminal, · or · Online + · or · [blank] · PreDef + · or · [blank] · Registration IP · Other Aliases · AppURQ · Unregister All · Disconnect Endpoint · Online Properties
Page 55 of the Multi-Tech Systems MVP103 user manual — ORIG ALIAS
Page 55 · click to enlarge
Page 55

Gatekeeper - Calls

The fields of the Current Calls screen are described in the table below.

Multi-Tech Systems MVP103 — Gatekeeper - Calls diagram (page 55)
Fig. 63 · Gatekeeper - Calls
Multi-Tech Systems MVP103 — Gatekeeper - Calls diagram (page 55)
Fig. 64 · Gatekeeper - Calls

The Calls window displays a list of all the calls currently taking place and the basic details of the calls:

Current Calls Field Definitions Field Name Values Description No numeric Number. A sequential number for identification in the list.

ORIG IP n.n.n.n 0-255 Originating IP Address. IP Address of endpoint originating the call.

ORIG ALIAS

Originating Alias. The first alias given by the call’s origin. The H.323 ID alias of the endpoint originating the call.

Disconnects the selected call.

Causes all current calls to disconnect.

Call Details Launches Call Details screen that presents technical particulars of an ongoing call.

Disconnect Call (button) · Disconnect All (button)

Page 56 of the Multi-Tech Systems MVP103 user manual — OR
Page 56 · click to enlarge
Page 56

A Call Details screen for a call in progress can be launched either by clicking on the “Call Details” button for a selected call in the Current Calls screen, or by double-clicking on a selected call listed in the Current Calls screen. The Call Details screen contains general information about the call, as well as details about the call’s source endpoint and destination endpoint.

Clicking on an in-progress call, or using the “Call Details” button, yields full details about the call

Multi-Tech Systems MVP103 — Gatekeeper - Calls diagram (page 56)
Fig. 65 · Gatekeeper - Calls

The Call Details screen consists of three panes: Call General Info, Destination Info, and Source Info. We describe the fields for each of these panes in a separate table below.

Multi-Tech Systems MVP103 — Gatekeeper - Calls diagram (page 56)
Fig. 66 · Gatekeeper - Calls

Call Details Field Definitions Field Name Values Description

Call General Info Call No. Call Number. Accession number identifying a call in progress. Cid Sum The conference ID number (CID) is a unique non-zero value created by the calling endpoint and passed in various H.225.0 messages. The CID identifies the conference with which the message is associated. Therefore, messages from all endpoints participating in the same conference will have the same CID. Call ID Sum The call ID number is a globally unique non-zero value created by the calling endpoint and passed in various H.225.0 messages. The Call ID identifies the call with which the message is associated.

Indicates whether the call is direct or routed. For direct-mode calls, the gatekeeper gives each endpoint involved in the call the destination address of the other and establishes a common call-signaling channel for them to use during the call. Then the two endpoints conduct the call without further gatekeeper involvement. For routed-mode calls, the gatekeeper establishes a connection between the two endpoints but keeps itself involved in call signaling for the duration of the call. In routed mode, the gatekeeper keeps a call-signaling channel open for the entire duration of the call. As a call-management service, the gatekeeper can change the routing of the call (by line hunting) while the calls is in progress. If the gatekeeper is to implement supplementary (H.450) services, it must operate in routed mode.

OR

Call Model direct · routed

Page 57 of the Multi-Tech Systems MVP103 user manual — Call Details Field Definitions (Cont’d) Field Name Values Description
Page 57 · click to enlarge
Page 57

Call Details Field Definitions (Cont’d) Field Name Values Description

Call General Info (cont’d) Total BW The total amount of bandwidth used by the call. Conf. Goal The type of conference request: create, invite or join. State The last reported state of the call.

Reason The reason associated with the last state of the call.

Multi-Tech Systems MVP103 — Call Details Field Definitions (Cont’d) Field Name Values Description diagram (page 57)
Fig. 67 · Call Details Field Definitions (Cont’d) Field Name V…

Call Details Field Definitions (Cont’d) Field Name Values Description

Names The H.323 alias name(s) for the originating endpoint.

The e164 alias phone number(s) of the originating endpoint.

Other AliasesEmail

An e-mail address of the originating endpoint.

OtherAliasesTrans. Name

Transport Name. An alias of the originating endpoint consisting of an IP address and port number.

Other AliasesURL

A Internet-type address of the originating endpoint.

The call signaling transport address of the originating endpoint.

Req. Bandwidth

Requested Bandwidth. The bandwidth requested by the calling endpoint for this call. App. Bandwidth

Approved Bandwidth. The bandwidth the Gatekeeper made available to the calling endpoint.

Source Info fields · Phone Numbers · Call Signaling IP

Page 58 of the Multi-Tech Systems MVP103 user manual — Field Name Values Description
Page 58 · click to enlarge
Page 58
Multi-Tech Systems MVP103 — Gatekeeper - Calls diagram (page 58)
Fig. 68 · Gatekeeper - Calls

Call Details Field Definitions (Cont’d)

Field Name Values Description

Names The H.323 alias name used to make the call.

The e164 alias phone number used to make the call.

Other AliasesEmail

An e-mail address used to make the call.

OtherAliasesTrans. Name

A transport name alias used to make the call, consisting of an IP address and port number.

Other AliasesURL

A URL alias used to make the call.

The call signaling transport address of the called endpoint.

Reg. Bandwidth

Requested Bandwidth. The bandwidth the called endpoint requested for the call, as it appears in the ARQ/BRQ messages.

App. Bandwidth

Approved Bandwidth. The bandwidth the Gatekeeper made available to the called endpoint for the call.

These allow calling with more than one B-channel.

This is the phone number of the called endpoint on the remote LAN. It is used for calls between multiple gateways.

This is the identifier (name) of the called endpoint on the remote LAN. It is used for calls between multiple gateways.

Show 6 more labels / short text on this page
Destination Info fields · Phone Numbers · Call Signaling IP · Additional Phone Numbers · Remote Extension Phone · Remote Extension Name
Page 59 of the Multi-Tech Systems MVP103 user manual — Gatekeeper – Network Parameters
Page 59 · click to enlarge
Page 59

Gatekeeper – Network Parameters

The fields of the Network Parameters screen must be configured as shown below.

Multi-Tech Systems MVP103 — Gatekeeper – Network Parameters diagram (page 59)
Fig. 69 · Gatekeeper – Network Parameters
Multi-Tech Systems MVP103 — Gatekeeper – Network Parameters diagram (page 59)
Fig. 70 · Gatekeeper – Network Parameters

Network Parameter Definitions Field Name Values Description Status Information Use Update button to refresh the Status Information fields.

number The number of current calls with the Gatekeeper.

number The number of endpoints registered with the Gatekeeper.

number The current bandwidth usage of the ongoing calls in Kbps.

Alias Giving Y/N When an endpoint sends an RRQ message, the Gatekeeper uses the

additional aliases that were predefined for the endpoint as online aliases. This enables the Gatekeeper to assign terminal alias names through which the terminal can be accessed by others. The following are two examples of how this option can be used: • Example of Alias Giving for a Terminal. To make a terminal accessible by dialing 100, add the alias 100 to the terminal’s predefined information, and select the Alias Giving option. When the terminal sends an RRQ message, the 100 alias becomes a dynamic (online) alias, and all calls to 100 will be directed to the terminal.

  • Example of Alias Giving for Gateways. To make all Gateways supply Service 80, add Service 80 to the Service Table, add the 80 alias as predefined information to all registered gateways, and select the Alias Giving option. When the gateways register, they will support Service 80.
Show 4 more labels / short text on this page
Ongoing Calls · Currently Registered · Current BW Usage · Configuration Options
Page 60 of the Multi-Tech Systems MVP103 user manual — Line Hunting
Page 60 · click to enlarge
Page 60

Network Parameter Definitions (cont’d)

Field Name Values Description Pre-Granted ARQ PreGrant ALL

Y/N Select to cause the Gatekeeper to send a pregrantedARQ permission in the RCF message for each endpoint that wishes to register. The pregranted ARQ permission is given to both makeCall and answerCall with routed mode. When an endpoint receives the permission, it may start the call with a Setup message or directly answer the call with a Connect message.

Line Hunting

Call to Out- of-Service Supplier

Y/N “Y” enables the sending of RAI messages. In a normal scenario, the gatekeeper will hunt among all the available endpoints that have been registered using the same tech-prefix. Each endpoint can inform the gatekeeper about its resource availability using an RAI (Resource Available Indication) message. Upon receiving an RAI message from an endpoint, the gatekeeper would consider that endpoint as an Out-of- Service Supplier. The ‘Almost Out of Resources’ configuration would allow the gatekeeper to hunt such Out-of-Service Supplier endpoints for routing the calls.

Remove H.245 Addr in Call Hunt

Y/N When selected, the gatekeeper will not convey in its outgoing setup message the H.245 address received in an incoming setup message. This prevents H.323 terminals from establishing a channel for a call only to refuse the call later.

Y/N When “Y” is selected, the gatekeeper will perform a Priority Based Line Hunting among those destinations registered using the same tech- prefix.

Call Proceeding This parameter group pertains to the gatekeeper’s handling of Q.931 “call-proceeding” messages.

Y/N Immediate return of call-proceeding message to originating endpoint. When selected, the gatekeeper will send the Q.931 call –proceeding message to the originating endpoint immediately after receiving that endpoint’s call setup request.

With H.245 Addr

Y/N When enabled, gatekeeper supplementary services will remove the H.245 address from the outgoing setup in order to prevent early H.245 establishment to the call’s destination. This destination can be changed during Forward on Busy or during Forward on No Response (CFNR).

Y/N Delayed return of call-proceeding message to originating endpoint. When selected (in routed mode), the gatekeeper will send a Q.931 call- proceeding message to the originating endpoint after it receives a return call-proceeding message back from the destination endpoint.

Show 4 more labels / short text on this page
Information · Service Configurable Properties · Send Immediately · After Overlapped Sending
Page 61 of the Multi-Tech Systems MVP103 user manual — Configuration
Page 61 · click to enlarge
Page 61

Network Parameter Definitions (cont’d)

Field Name Values Description Call Mode

Direct Mode Sets the call mode to direct. In this mode, terminals send ARQ messages to the Gatekeeper, but pass the call signaling and media control signaling directly between them.

Sets the call mode to routed. In this mode, terminals pass admission requests and call signaling through the Gatekeeper. Media control information is sent directly between the terminals. Note: Though direct calls consume fewer Gatekeeper resources, call control is better for indirect (or routed) calls.

Configuration

Max Number of Calls

The maximum number of concurrent calls allowed in the zone. This number is fixed to 5, 10, or 15 call for MVP210-AV, MVP410-AV, and MVP810 models respectively.

Max Total BW (KBps)

The amount of bandwidth in Kbps that call traffic can consume at any given time.

Registration Timeout. Sets the number of hours of inactivity after which the dynamic registration of a terminal expires. Only the dynamic (online) properties will be unregistered. If the endpoint is also static (predefined), the static properties remain valid.

The interval, in seconds, between IRQ messages sent by the Gatekeeper. IRQ messages are sent to all online endpoints registered as dynamic in order to verify that the endpoints are online. The number you set determines the delay between two IRQ messages to the same endpoint. Choosing the desired delay should take into account the following factors:

  • IRQ messages add to the traffic already present over the network, and the shorter the delay, the more IRQ messages are sent. However, the longer the delay, the longer it takes for the Gatekeeper to detect dynamic registrations that have ceased to be online.
  • The delay parameter relates to the interval between two IRQ messages per one endpoint, so the actual number of the IRQ messages the Gatekeeper creates during this interval should be multiplied by the number of endpoints registered dynamically.
  • To disable the IRQ polling, set this value to zero.
  • The effective IRQ interval cannot fall below three times the RAS timeout.
  • IRQ messages will not be sent at a rate exceeding 20 per second.
Show 4 more labels / short text on this page
Routed Mode · Parameters · Registration TO (hrs) · IRQ Interval (sec)
Page 62 of the Multi-Tech Systems MVP103 user manual — Field Name Values Description Configuration Parameters (Cont’d)
Page 62 · click to enlarge
Page 62

Network Parameter Definitions (cont’d)

Field Name Values Description Configuration Parameters (Cont’d)

The interval, in seconds, between IRQ messages sent by the Gatekeeper to query the status of calls. IRQ messages are sent to all online endpoints registered as dynamic and having ongoing calls in order to verify that the calls are still ongoing. The number you set determines the delay between two IRQ messages to the same endpoint regarding the same call. Choosing the desired delay should take into account the following factors:

IRQ messages add to the traffic already present over the network, and the shorter the delay, the more IRQ messages are sent. However, the longer the delay, the longer it takes for the Gatekeeper to detect calls that are stale. The delay parameter relates to the interval between two IRQ messages per one call, so the actual number of the IRQ messages the Gatekeeper creates during this interval should be multiplied by the number of ongoing calls registered dynamically. To disable the IRQ polling, set this value to zero. The effective IRQ interval cannot fall below three times the RAS

timeout. IRQ messages will not be sent at a rate exceeding 20 per second.

The “distance” (number device-to-device hops that a call must traverse between endpoints) allowed for endpoints which are only dynamically registered, such as an endpoint with no predefined values. This distance is compared to the distances of the neighbor gatekeepers and to the multicast distance in order to determine if an LRQ can be sent on behalf of the requesting endpoint.

software version.

The “distance” (number device-to-device hops that a call must traverse between endpoints) allowed for an out-of-zone endpoint that is making a call through the Gatekeeper. This distance is compared to the distances of the neighbor gatekeepers and to the multicast distance in order to see if an LRQ can be sent on behalf of the requesting endpoint.

The “distance” (number device-to-device hops that a call must traverse between endpoints) associated with sending an LRQ by multicast.

GK-ID The name of the Gatekeeper. The terminals identify the Gatekeeper by this name during the discovery process. The Gatekeeper responds only to Discovery requests that either contain a matching Gatekeeper identifier or have no Gatekeeper identifier.

-- Click to update information in the “Status Information” fields of the Network Parameters screen.

Show 5 more labels / short text on this page
Call IRQ Interval · Default Distance · Out-of-Zone Distance · Multicast Distance · Update (button)
Page 63 of the Multi-Tech Systems MVP103 user manual — Services Screen Definitions Field Name Values Description GK Defined Services
Page 63 · click to enlarge
Page 63

Gatekeeper - Services

The fields of the Services screen are described in the table below.

Multi-Tech Systems MVP103 — Gatekeeper - Services diagram (page 63)
Fig. 71 · Gatekeeper - Services
Multi-Tech Systems MVP103 — Gatekeeper - Services diagram (page 63)
Fig. 72 · Gatekeeper - Services

Services Screen Definitions Field Name Values Description GK Defined Services

Prefix A prefix that identifies the service. Description A description of the service that is accessible by dialing the prefix. See “GK Defined Service Types” section on following pages. Default For any GK-defined service being used, the user must select either “Default” or “Public.” When Default is selected, the service is accessible to all endpoints that are not predefined in the zone. Public For any GK-defined service being used, the user must select either “Default” or “Public.” When Public is selected, the service is accessible to all endpoints that are not part of the zone.

Page 64 of the Multi-Tech Systems MVP103 user manual — Gatekeeper - Services
Page 64 · click to enlarge
Page 64

Services Screen Definitions (cont’d) Field Name Values Description V2 GW Prefixes H.323 Version 2 enables the gateway to specify prefixes that the user should dial before the WAN number in order to make a call using a certain medium. E.g., the user could dial the prefix 3 for voice calls or 77 for H.320 video calls. The prefixes are defined in the RRQ message at registration. Prefix can be any H.323 alias, including an H.323 ID & mail address.

When a terminal places a LAN to WAN call, it should add one of the prefixes to the dialed number. The Gatekeeper identifies the prefix & routes the call to the appropriate gateway. If more than one gateway supplies the same prefix, line hunting is possible between the gateways. Prefix Identifies the service. The prefix can be a numeric code, alphanumeric string, name, or phone number that the user dials. Per H.323 Vers. 2, prefixes can also be of URL and e-mail type. Also for H.323 Vers. 2, the type must precede the prefix. For example, TEL: 3 or NAME: John. Description A description of the service that is accessible by dialing the prefix. Default Select to make the service accessible to all endpoints that are not predefined in the zone. Public Select to make the service accessible to all endpoints that are not part of the zone. Dynamic Y/N Indicates whether the service is static (essentially permanent) or timed & conditional (dynamic). This field indicates whether the service has been added manually (non-dynamically; field value =N) or dynamically (field value = Y) as part of registration from endpoints. Buttons These buttons allow you add, edit, or delete a selected service or prefix.

Page 65 of the Multi-Tech Systems MVP103 user manual — Chapter 4 - Miscellaneous
Page 65 · click to enlarge
Page 65

Chapter 4 - Miscellaneous

Chapter 4 - Miscellaneous

Gateway Survivability Mode

A customer may wish to have some ports on the MultiVOIP gateway not be managed by CM, but rather have them directly routed over a private IP WAN to a second MultiVOIP gateway at the side of the WAN network. An example of this would be to send a T.38 fax call over the private IP WAN network to a fax port on a second MultiVOIP gateway.

Create phonebook entries for optional gateway survivable mode (if chosen). In this mode, the MultiVOIP provides survivability to local FXS/FXO ports; IP phones are not supported. If IP phone survivability is desired, it is recommended that you configure gatekeeper survivability in Section 6 and skip this section.

MultiVOIP PhonebookA Communication Manager Example
1. An MVP810 (eight-channel) MultiVOIP is used
2. The MultiVOIP’s first six ports are used for analog stations with extensions numbers (6001-6006).
3. The MultiVOIP’s last two ports are used for analog FXO trunks that may be reached by dialing 9 plus the local area codes of “303” or “720”.
4. The IP address of this MVP810 is 204.26.122.1.

5. The incoming PSTN trunk calls from either port #7 or port #8 will use the “AutoCall” feature and will be routed to the first station port. This port will serve as an “attendant” during survivability. NOTE. Normally the “AutoCall” register will have the PBX extension of 8001 that will be forwarded up to the MultiVantage server. But in this example of survivable mode operation, the 8001 will be routed to local station port 6001 with the help of the Outbound Phonebook table.

6. The Q.931 Signaling Port value of each Outbound Phonebook entry must match the Call Signaling port value configured for the destination voice channel in the Communication Manager Settings screen. The MultiVOIP’s Outbound PhoneBook will be configured as illustrated in the table below.
MultiVOIP PhonebookA Comm Mgr Example

Add Prefix IP Address

6001 204.26.122.1 6002 204.26.122.1 6003 204.26.122.1 6004 204.26.122.1 6005 204.26.122.1 6006 204.26.122.1 8001 8001 6001 204.26.122.1 9303 204.26.122.1 9720 204.26.122.1

Outbound Destination Pattern · Remove Prefix

Page 66 of the Multi-Tech Systems MVP103 user manual — Gatekeeper - Services
Page 66 · click to enlarge
Page 66

Chapter 4 – Miscellaneous

The Inbound Phonebook will be configured as illustrated in the table below.

Inbound Destination PatternFilter & Remove this Prefix

Add Prefix Channel to direct call toward

6001 1 6002 2 6003 3 6004 4 6005 5 6006 6 9303 303 7 9303 303 8 9720 720 7 9720 720 8

Comm Mgr Dialing Example #1A local station-to-station call
1. The station at FXS port #1 goes off hook and received the survivable dial tone from the MultiVOIP gateway. The client then proceeds to dial “6002”.
2. The dialed digits are conveyed, per the instructions of the “Outbound Phonebook,” to IP address 204.25.122.1 (which is the self-same MultiVOIP unit).
3. The “Inbound Phonebook” filters on the dialed string “6002” and sees that it is destined for port #2, and ringing tone is applied to station 6002.
4. When station 6002 answers, the call is completed.

Comm Mgr Dialing Example #2: A local analog station dials outward on the local analog trunk to gain access to the local central office.

1. The station at FXS port #1 goes off hook and receives the survivable dial tone from the survivable gateway. The client then proceeds to dial “93035380000”.
2. These dialed digits are forwarded, per the instructions of the “Outbound Phonebook,” to IP address 204.25.122.1 (which is the self-same MultiVOIP unit).
3. The “Inbound Phonebook” filters the dialed digits because it detects the string “9303.” Acting per its configuration, it removes “9303,” adds “303” and directs that the call be dialed out to either FXO trunk port #7 or #8. It would have been possible to direct calls with these dialed sequences simply to one port (for example, to port #7). Because two ports are listed, the gateway will hunt for an available port.
4. The selected trunk port activates its tip/ring loop-start interface and the digit string “3035380000” is dialed out toward the network.
5. When the called party of 5380000 answers the call, the call is completed.
Page 67 of the Multi-Tech Systems MVP103 user manual — Remote Configuration
Page 67 · click to enlarge
Page 67

Chapter 4 - Miscellaneous

Remote Configuration

Remote configuration provides procedures for viewing or changing the configuration of a remote MultiVOIP. Remote configuration requires the MultiVOIP software to be loaded on the local PC. The local PC then controls the remote MultiVOIP. To accomplish this, a MT5634ZBA modem is included with your MultiVOIP, except on models MVP130-AV and MVP130-AV-FXS. Two serial cables are also included, the DB25 male to RJ45 cable is used with the MultiVOIP (MVP210 model) or the DB25 male to DB25 male (larger connectors) is used with the MultiVOIP (MVP410 and MVP 810 models). Note: On some MVP410 and MVP810 models, the modem is built in. On these models, connect the dial-up line to the RJ11 modular connector labeled Command Modem. To remotely configure a MultiVOIP, a local PC needs to be connected to a dial-up line and the MultiVOIP software configured to call the remote MultiVOIP. The remote MultiVOIP needs to have the MT5634ZBA modem connected to a dial-up line and the Command Port. Once the connection to the remote unit is made, you can change the configuration as required. Once the configuration is changed, you can download the new configuration to the remote MultiVOIP.

1. At the remote site, verify that the “Console Messages” in the Configuration Logs dialog box is disabled before you power down the remote MultiVOIP. 2. At the remote site, remove the serial cable from the PC to the Command Port connector on the back panel of the MultiVOIP. 3. At the remote site, connect one of the serial cables provided from the Command Port connector on the back panel of the MultiVOIP to the RS-232 connector on the modem. 3a. Connect the modem to your local telephone line. 3b. Provide your telephone number to the person verifying your configuration. 3c. Power On the modem first to allow it to initialize. Then power On the MultiVOIP. 4. At the main site, connect your local PC to a modem that is connected to a dial-up line. 5. Install the MultiVOIP software on the local PC. When installed, click Start|Programs|MultiVOIP 9.06.XX|Configuration Port Setup. 6. The Comm Port Setup dialog box displays.

Multi-Tech Systems MVP103 — Remote Configuration diagram (page 67)
Fig. 73 · Remote Configuration

Verify that the Select Port box is set for the COM port of your local PC and that the Baud Rate is set to 115200. In Modem Setup, the modem Initialization String, Initialization Response, and Connect Response should be configured as shown in the above dialog box.

Page 68 of the Multi-Tech Systems MVP103 user manual — Gatekeeper - Services
Page 68 · click to enlarge
Page 68

Chapter 4 – Miscellaneous

In the Dial String box, enter the AT command for dialing (atdt) plus the phone number of the remote MultiVOIP. Click OK when you are satisfied with your selections. 7. Run the MultiVOIP Configuration program. Click Start|Programs| MultiVOIP 9.06.XX Configuration. 8. The Dialing dialog box displays while software is dialing the remote MultiVOIP. 9. The Reading Setup dialog box displays. 10. The MultiVOIP main menu displays. This is the main menu of the remote MultiVOIP. 11. Change the configuration of the remote MultiVOIP and then click Save and Reboot to update the configuration. The remote MultiVOIP will be brought down, the new configuration written to the unit, and the unit will reboot. 12. Close the configuration program when the downloading is complete. 13. If the same telephone number is not going to be used again in the immediate future, you may want to remove it from the Port Setup dialog box.

Page 69 of the Multi-Tech Systems MVP103 user manual — Information
Page 69 · click to enlarge
Page 69

Chapter 4 - Miscellaneous

Information

The System Information screen displays version and addressing information on your MultiVOIP.

Multi-Tech Systems MVP103 — Information diagram (page 69)
Fig. 74 · Information

The System Information screen is a display information screen with such information as Firmware Version level, MAC Address, and Serial Number which can be helpful in identifying your unit when contacting Technical Support.

Boot Version: This field displays the version of the boot code running on the MultiVOIP. The boot code operates during initial power-up and during the firmware upgrades.

Firmware Version: Displays the firmware version running on the MultiVOIP. The MultiVOIP receives operating instructions from firmware during normal operation.

Configuration Version: Displays the version of the configuration file being used by the MultiVOIP.

Phone Book Version: Displays the version of the Phone Book file being used by the MultiVOIP.

MAC Address: Displays the MAC address assigned to the MultiVOIP’s Ethernet port.

Uptime: Displays how long the MultiVOIP has been operating since the last power-up or Save and Reboot operation.

Hardware ID: The hardware ID determines the MultiVOIP model and features supported.

Displayed Hardware ID Interfaces Supported Configuration Modem MVP130-AV Rev 0 FXS/FXO No MVP130-AV Rev A FXS/FXO/DID No MVP130-AV-FXS Rev A FXS No MVP210-AV Rev A FXS/FXO No MVP210-AV Rev B FXS/FXO/DID No MVP410-AV Rev A FXS/FXO No MVP410-AV Rev B FXS/FXO/DID Yes MVP810-AV Rev A FXS/FXO No MVP810-AV Rev B FXS/FXO/DID Yes

Page 70 of the Multi-Tech Systems MVP103 user manual — Gatekeeper - Services
Page 70 · click to enlarge
Page 70

Chapter 4 – Miscellaneous

For example, a MVP810-AV may have Revision C printed on the packaging label and PCB, but display “MVP810-AV Rev B” in System Information. This means no new features were added in Rev C and it supports the same features as the Rev B (FXS/FXO/DID).

Page 71 of the Multi-Tech Systems MVP103 user manual — Link Management
Page 71 · click to enlarge
Page 71

Chapter 4 - Miscellaneous

Link Management

The Link Management screen allows you to ping a remote system by entering the IP address of the remote unit in the IP Address to Ping field. The Link Status window displays the results of the ping.

Multi-Tech Systems MVP103 — Link Management diagram (page 71)
Fig. 75 · Link Management

Each ping test sends a user configurable number of pings to the remote unit. Configure the Time Interval between Tests field to the number of minutes (0-30) to wait between each ping test. If this field is set to 0, only one ping test is performed. The Ping Size in Bytes and Response Timeout values can be changed to accommodate various packet sizes or network delay conditions. The results are displayed under Link Status and consist of IP Address, No of Pings Sent, No of Pings Received, Round Trip Delay (Min/Max/Avg), and last Error. You can compare the number of pings sent/received and Round Trip Delay to determine the condition of the network between the two units. Ping tests are discontinued when you exit the Link Management screen.

Page 72 of the Multi-Tech Systems MVP103 user manual — Feature Issues
Page 72 · click to enlarge
Page 72

Chapter 4 – Miscellaneous

Feature Issues

1. Calling Party Number is not displayed on the Caller ID for FXS ports after receiving a call via CM. This is due to CM not sending the Calling Party Number to the MultiVOIP as part of the Q.931 setup message.
2. “Unknown Name” is displayed on the Caller ID for FXS ports after receiving a call from a MultiVOIP FXO port that was routed by CM. This is due to CM sending “Unknown Name” in the Display field of the Q.931 setup message instead of the actual Caller ID Name received by the MultiVOIP FXO port.
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Multi-Tech Systems MVP103

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Multi-Tech Systems MVP103

Be the first to ask — other owners or our team will answer.

Original document

Multi-Tech Systems MVP103 manual PDF

79 pages·3 MB·IP Phone·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…