

External ISDN Terminal Adapter
User Guide


S000305B Rev. B
This publication may not be reproduced, in whole or in part, without prior written permission from Multi-Tech Sys- tems, Inc. All rights reserved.
Copyright © 2004 by Multi-Tech Systems, Inc.
Multi-Tech Systems, Inc. makes no representations or warranties with respect to the contents hereof and specifi- cally disclaims any implied warranties of merchantability or fitness for any particular purpose. Furthermore, Multi- Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revi- sions or changes.
A 7/25/03 The manual replaces 82052305 Rev. G. Manual updated with NT info. AT commands and S registers moved into additional documentation on CD.
B 11/05/04 Changed temperature from -50 to-40 C.
IWay, IWay Hopper, Multi-Tech, and the Multi-Tech logo are trademarks of Multi-Tech Systems, Inc. AT&T and 5ESS are registered trademarks of American Telephone and Telegraph. Microsoft, Windows, and Windows 95 are registered trademarks of Microsoft Corporation. NETCOM is a registered trademark of NETCOM On-Line Communication Services, Inc. Netscape and Navigator are trademarks of Netscape Communications Corp. DMS-100 is a trademark of Northern Telecom. All other trademarks are owned by their respective companies.
Multi-Tech Systems, Inc.
2205 Woodale Drive Mounds View, MN 55112
Telephone (763) 785-3500 or (800) 328-9717
Fax (763) 785-9874 Technical Support (800) 972-2439 Internet http://www.multitech.com
Revision Date Description · Trademarks



Chapter 1: Intr er 1: Intr er 1: Intr er 1: Intr er 1: Introduction and D tion and D tion and D tion and D tion and Description
Welcome to the world of ISDN communications.
You have acquired one of the finest ISDN terminal adapters (TAs) available today, model MTA128ST/NT from Multi-Tech Systems. The MTA128ST is a desktop TA with an S/T interface port to connect it to the ISDN network and an analog port to connect it to a telephone, modem, or fax machine. The MTA128NT is a desktop TA with a U-interface to connect it to the ISDN network and an analog port to connect it to a telephone, modem, or fax machine. The TAs ship with a software configuration utility for Windows® 98/NT/ ME, and ConfigMenu, a built-in configuration utility for Windows and non-Windows operating systems. In addition, the MTA128ST/NT accepts AT commands that enable it to use the same communications software as an analog modem.
The MTA128ST is compatible with the popular EuroISDN switch protocol, it communicates using ISDN BRI (2B+D) service, which provides up to 128 Kbps data and voice communications, and it automatically detects whether an incoming call is voice or data and handles it appropriately.
The MTA128ST/NT provides dial-up asynchronous communication capability with other personal computers, terminals, on-line computer services, or other computer systems. Connection to your computer/terminal device is made via the RS232 connector (ISDN). Connection to analog devices is accomplished with an RJ11 connector and one RJ45 connector is used for your ISDN connection.
This User Guide will help you install, configure, and operate your MTA128ST/NT.
There are two ISDN interface options, S/T and U. If you purchased the S/T interface adapter (MTA128ST), you need an ISDN NT1 device connection to the ISDN switch. If you purchased the U interface adapter (MTA128NT), it can directly connect to the ISDN switch (figure 1-1).

Figure 1-1. ”S/T” and “U” Interface Options
Your ISDN TA is compatible with prevalent ISDN switch protocols. It communicates using ISDN BRI (2B+D) service, which provides up to 128K bps data communications.
Introduction and Description ·

This manual documents the following models:
Some analog devices, including telephone set, answering machine, and modem, can be connected to the POTS port via an RJ-11 jack.
This User Guide will help you install, configure, and operate your terminal adapter. Features
The MTA128ST/NT communicates over public ISDN telephone lines. Features include:
Before running the ISDN adapter, you need to get an ISDN BRI (Basic Rate Interface) line from your local telephone company. Your ISDN service provider will provide information to you about the ISDN central switch type, pertinent subscriber information and SPID (Service Profile ID) number(s) if required .
SPID (Service Profile ID)
The Service Profile ID (SPID) is applicable in the U.S. only. SPIDs are a series of numbers that inform the central office switch which services and features to provide to an ISDN device. The generic SPID format comprises 14 digits. The first 10 digits are the main telephone number on the terminal. The last 4 digits are dependent on the number of terminals on the interface and the services they support.
An ISDN Basic Rate (BRI) U-Loop consists of 2 conductors from the CO (telephone company central office) to the customer premises. The equipment on both sides of the U-loop has been designed to deal with the long length of the U-loop and the noisy environment it operates in. At the customer premises the U-loop is terminated by an NT1 (network termination 1) device. An NT1 is a device which provides an interface between the two-wire twisted-pairs used by telephone companies in their ISDN BRI network and an end-user's four wire terminal equipment. The NT1 drives an S/T-bus which is usually made up of 4 wires, but in some cases may be 6 or 8 wires.
The name of the S/T bus comes from the letters used in the ISDN specifications to refer to two reference points, S and T. Point T refers to the connection between the NT1 device and customer supplied equipment. Terminals can connect directly to NT1 at point T, or there may be a PBX (private branch exchange, i.e. a customer-owned telephone exchange). When a PBX is present, point S refers to the connection between the PBX and the terminal. Note that in ISDN terminology, "terminal" can mean any sort of end-user ISDN devices, such as data terminals, telephones, FAX machines, etc. The diagram which follows reflects interface points in a typical ISDN network.
Introduction and Description · ISDN BRI Line · NT1 Connection

If your ISDN product operates with a S/T outlet interface, you need an NT1 device to connect to the ISDN switch. MTA128ST adapters need an NT1 device to connect to the ISDN switch, but the MTA128NT adapter does not require NT1 device. In the UK, and in many European countries, NT1 device is supplied by your telephone company.

Point “S” Point “S”
Figure 2-1 ISDN Interface Points
S/T Interface The S/T interface uses an 8-conductor modular cable terminated with an 8-pin RJ-45 plug. An 8-pin RJ-45 jack located on the terminal is used to connect the terminal to the DSL (Digital Subscriber Loops) using this modular cable.

Introduction and Description · Terminal · Terminal

U Interface The U interface uses a 2-conductor twisted pair cable terminated with an RJ-45 jack. An RJ-45 jack located on the terminal is used to connect the terminal to the Digital Subscriber Loops using this twisted pair cable.
In Table 2-2 the Pin Number, Terminal Pin Signal Name and UILC Pin Signal Names for the U interface are listed.

Introduction and Description

The ten LED indicators on the front panel (see figure below) of the MTA128ST/NT report status and line activity.
Flashes when data is being transmitted (on for a space, off for a mark).
Flashes when data is being received (on for a space, off for a mark).
For EuroISDN NET3, INS64, and VN4 switch protocols, lights when the TA is turned on. For US NI-1, DMS-100, and AT&T 5ESS switch protocols: On Steady, Link with central office is established (requires correct configuration of SPIDs) Flashing, Physical layer is down or one or both SPIDs have not been verified with central office
When lit, indicates active data or voice connection on bearer channel 1.
When lit, indicates active data or voice connection on bearer channel 2.
Lights to indicate that the computer is communicating with the MTA128ST/NT, so the MTA128ST/NT can answer an incoming call.
Lights when analog equipment on AUX port is active or off-hook.
Lights to indicate that the B channels have been multiplexed into a single 128 Kbps communications link.
Lights in combination with P2 and 128 LEDs to indicate which data protocol (V.110, V.120, X.75, PPP, MLPPP) is in use as shown in the table below.
Lights in combination with P1 and 128 LEDs to indicate which data protocol (V.110, V.120, X.75, PPP, MLPPP) is in use as shown in the table below.

! " #
$$$ ! " #
%$$$ ! " #

Trade Name IWay Hopper™ Model Number MTA128ST (International), MTA128NT Network Interface ST-Four-wire S/T interface NT– 2-wire “U” interface Switch CompatibilityEuroISDN (ETSI/DSS1/NET3), VN4, INS64, U.S. NI-1, AT&T 5ESS,
DMS-100 (both models support all of the switch protocols) B-Channel ProtocolsV.110 (some models only),V.120, X.75, PPP, ML-PPP, CLEAR Voice Coding PCM: A-Law ; µ-Law (switch protocol dependent) LED Indicators 10 front panel LED indicators: Transmit Data, Receive Data, Link Status, B1 Active, B2 Active, Terminal Ready, Off Hook (AUX port), 128 Kbps, P1 Active (data protocol), P2 Active (data protocol) Data Rates 300, 1.2K, 2.4K, 4.8K, 9.6K, 19.2K, 38.4K, 56K, 57.6K, 64K, 115.2K, 230.4K, and 460.8K bps Async Data Format 7 bit data + odd/even parity + 1 start/stop, 8 bit no parity. 36 baud rate/parity settings via S-register. Baud rates of 300–460.8K bps with even, space, mark, odd, or no parity. Data Connections Two ISDN B-channels One ISDN D-channel One analog port for connecting a standard telephone, modem, or fax machine Command Interface AT commands, S-registers, result codes, ConfigMenu firmware configuration utility,
Windows 98/NT/ME configuration utility, Dial-Up Networking (DUN) Connectors ISDN: RJ-45 female receptacle, 4-wire S/T (accepts connection cable to the network provider’s NT1 device) or 2-wire U interface AUX: RJ-11 female receptacle, 2-wire voice service Serial Port: female DB-25 RS232E/V.24 Serial Interfaces ITU-T V.24, EIA/TIA RS232E Switches Two-position power switch Power RequirementsTwo-prong outlet-mounted transformer (included), 240 VAC 50/60 Hz Dimensions 15.0 cm × 10.7 cm × 2.8 cm (L × W × D) Environmental Temperature range 0°–40° C (32°–104°F) Humidity range 20–90% (noncondensing) Power Consumption 4 watts Weight 224 g (8 oz) Warranty 5 years
Introduction and Description

Chapter 2: Har er 2: Har er 2: Har er 2: Har er 2: Hardwararararare Installation e Installation e Installation e Installation e Installation
This chapter shows you step-by-step how to set up your MTA128ST/NT terminal adapter (TA) to your computer, power, network terminator, and an auxiliary analog device. Please follow these instructions carefully to avoid damage to your TA .
Turn off your computer. Place the modem in a convenient location, connect it to your computer’s serial port, to the phone line, to AC power, and to your phone.

Cable Connections.
Hardware Installation

Plug the DC power transformer into an AC power outlet or power strip. Plug the DC power transformer into the POWER jack on the TA.
Turn on the TA by sliding the power switch to ON and verify operation by observing the LEDs on the front panel. The LEDs first flash in a self-test pattern. Then the LS LED remains on. If the TA does not appear to be working, Refer to Chapter 5 for troubleshooting help.
Plug one end of the RS-232 serial cable into the RS-232 connector on the modem, and plug the other end into a serial port connector on your computer, such as COM1 or COM2. You supply the RS-232 cable.
If you need a longer cable than the one provided with your TA, select a cable that is wired straight through (pin 1 to pin 1; pin 2 to pin 2, etc) with at least the middle four pins connected (pins 3, 4, 5, and 6).
Plug one end of the cable into the ISDN jack on the TA and the other end into the jack on your network terminator (MTA128ST) or U-interface (MTA128NT).
You can connect an analog device such as an analog telephone, modem or fax machine to the TA. Simply put the device’s module telephone cable into the PHONE Jack (RJ11) on the TA.
Hardware Installation

Chapter 3: C er 3: C er 3: C er 3: C er 3: Configuration Utilities ation Utilities ation Utilities ation Utilities ation Utilities
You can configure the MTA128ST/NT to match your ISDN service and the remote terminal adapter (TA) with any of four methods listed below:
Whatever method you use to configure your TA, consider your network and call control configuration choices and COM port settings beforehand listed below and record your choices. Refer to them during the configuration procedure.Before you begin, verify your switch type and TEI with your local ISDN provider and have that information readily available
Network Switch Type Select the network switch type your ISDN service provider uses at its local central office. You can set the MTA128ST/NT to NET3 (DSS1), VN4, INS64, U.S. NI-1, AT&T 5ESS, or DMS-100. If you don’t know the switch type, get the information from your ISDN service provider.
Data TEI Data TEI is the TEI assigned to the data channel. You can select Auto TEI, a fixed TEI, or Disable. A TEI (terminal endpoint identifier) is a number used by the central office switch to uniquely identify each device connected to the network. When it uses dynamic TEI assignments (Auto TEI), the central office switch assigns a TEI each time the TA connects to the network. However, the ISDN service provider may assign a fixed TEI at subscription time, in which case you must configure the TA with the fixed TEI number. You also can disable the channel, which may be useful when multiple TAs are attached to a network terminator bus. AT command: !D3=
Voice TEI Voice TEI is the TEI assigned to the voice channel. Choices are: Auto TEI, a fixed TEI number, or Disable. AT command: *!D3=.
Configuration Utilities · Data MSN

The Data MSN (multiple subscriber number) allows a caller to specify an individual TA when more than one TA is connected to you network terminator. If you don’t assign a value to the MSN, the TA accepts all incoming calls. If you only assign a base address to the MSN, the TA accepts any incoming call with the same base address, regardless of whether a subaddress is included. If you assign a base address and a subaddress to the MSN, the TA only accepts calls that match both the base address and the subaddress. The following examples show the syntax for setting the MSN with and without a subaddress.
Voice MSN Selects calls on the voice channel in the same way the Data MSN selects calls on the data channel.
SPIDs and DNs The TA must be configured with the Service Profile Identifier (SPID). The SPID is assigned by the local phone company and is for the specific BRI line where the TA is attached. The SPID field is empty prior to configuration. AT commands: AT!C6= and AT*!C6=
Directory Number (DN) is the phone number another user calls to contact this TA once it is attached to the ISDN. AT commands: AT!N1= and AT*!N1=
Persistent DTR Dialing A high DTR (Data Terminal Ready) signal on the RS232/V.24 serial port indicates your computer or terminal is ready to communicate with your TA. DTR normally goes high when a communication program starts or is ready to dial. Persistent DTR dialing enables the TA to automatically redial the number stored in memory location 0 whenever DTR is high and the serial port does not have an active call. You can enable or disable this feature. AT command: $D.
Auto Answer Data Calls Rings to Answer Select Auto Answer if you want your TA to automatically answer all incoming data calls (this option does not affect the analog port). The Rings to Answer number, in the range of 1 to 255, selects the number of rings the TA waits before answering an incoming call. The default is one ring.
Dialing Method Select either the Enbloc or the Overlap dialing method for use when establishing a data call. Your ISDN provider determines the dialing method. The enbloc method is used for most ISDN dialing; however, you can select the overlap method if you are working with a private network.
Data Protocol The data protocol, also known as the B-channel protocol and the rate adaption protocol, is the language spoken over each 64 Kbps channel between two ISDN devices. The devices on both ends of the ISDN link must use identical protocols.
V.110 Protocol (some models only) — Used to connect slower, pre-ISDN communications devices to high-speed ISDN lines. It handles rates up to only 38400 bps and is used mostly in Europe. The devices on both ends of the link must be set to identical rates.
Configuration Utilities

V.120 Protocol—Similar to V.110 protocol, but provides rates up to 64000 bps on each B channel.
X.75 Protocol—Packet-switched network protocol for international use. Layer 2 portion of this protocol is used commonly as a rate adaption protocol.
MLPPP Protocol—MLPPP (Multi-Link PPP) protocol provides rates up to 64 Kbps per channel. This protocol uses both B channels at once, providing an aggregate data transmission speed of 128 Kbps.
Dialing Numbers The MTA128ST/NT can dial telephone number n, where n can be up to 20 characters. AT command: Dn (n = phone number). Stored Numbers The MTA128ST/NT can store as many as ten phone numbers, up to 20 characters each. AT command: &Z= Dialing Stored Numbers The MTA128ST/NT can dial a number previously stored in directory number n with the &Zn=x command. AT command: e.g., DS3 COM Port Settings
COM port settings control how your TA communicates with your computer through the RS232/V.24 serial port. Baud Rate or Bit Rate Select the initial speed at which your TA communicates with your computer. For V.110 data protocol, the rates must be identical on the local and remote TAs and may not exceed 38400 bps. For all other data protocols (V.120, MLPPP, X.75, etc.), the default initial baud rate is 115200 bps. Typically, in command mode, the MTA128ST/NT selects a serial port speed of 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, or 230400 bps depending on how fast the AT commands are coming from the computer or terminal. The $SBn command sets the default serial speed used when the TA first powers up. Using the %S command you can disable automatic speed selection and lock the serial port speed to 460800 bps. See Serial Port Configuration Commands in Chapter 4 for more information. AT commands: $SB or %S
Flow Control Select the method by which your TA and computer control the flow of data between them. Unless you know your computer has special requirements, select the default RTS/CTS method. The other choice is XON/ XOFF. AT command: &E Data Bits, Parity, and Stop Bits These settings further control initial communications between the TA and computer. Unless you know your computer has special requirements, use the default settings of 8 data bits, no parity checking, and 1 stop bit (8-N-1). The TA sets these parameters automatically the first time it receives an AT command from the computer. AT commands: @P4=, @P3=, @P6=
DTR Detect Time Sets the time, in 0.1-second increments, that DTR must remain low before the TA disconnects. The default value is 0.5 second; however, you can set it anywhere within the range 0–255 (0.05–25.5 seconds). AT command: S25=
DCD Drop Time Sets the time, in 0.1-second increments, that a carrier must be lost before the TA disconnects. The default value is 0.7 seconds; however, you can set it anywhere in the range 0–254 (0–25.4 seconds). Setting DCD Drop Time to 255 causes the TA not to disconnect with loss of carrier when DCD Control is set to Momentary Drop. AT command: S10=
Configuration Utilities

DTR Control A high DTR (Data Terminal Ready) signal on the RS232 serial port indicates your computer or terminal is ready to communicate with your TA. It normally goes high when a communication program starts or is ready to dial. Normal causes the TA to break the link and go into command mode when DTR drops. Ignore causes the TA to ignore the DTR signal. Reset on DTR causes the TA to reset when DTR drops for the time specified in register S25. AT command: &D
CTS Control A high CTS (Clear to Send) signal on the RS232 serial port indicates the TA is ready to receive data. Normally, it follows the state of the RTS signal. Select Normal to make CTS act normally. Select Always On to force CTS high when the TA is offline. When the TA is online, CTS still provides flow control. Select Momentary Drop to cause CTS to drop momentarily when the link is lost; then to go high again. AT command: &R
DSR Control A high DSR (Data Set Ready) signal on the RS232 serial port indicates your TA is ready to communicate with your computer or terminal. Normally, it follows the state of the DTR signal. Select Normal to make DSR act normally. Select Always On to cause the TA to ignore the state of the DTR signal. Select Momentary Drop to cause DSR to drop momentarily when the link is lost; then to go high again. AT command: &S
DCD Control Normally, the DCD (Data Carrier Detect) signal on the RS232 serial port goes high when the TA receives a connect message from a remote TA, and drops when the link is lost. Select Always On to satisfy a requirement by some software packages for this state to be present constantly. Select Normal for normal operation. Select Momentary Drop to cause DCD to drop momentarily when the link is lost; then to go high again. The length of the drop is governed by register S10. AT command: &C
Asynchronous/Synchronous Mode Normally, the MTA128ST/NT communicates in asynchronous mode. If you need transparent synchronous communication, change this register setting. AT command: &M
Configuration Utilities

If you use Windows 98/Me/NT, perform the following procedure using the Configuration Utility provided on your system CD. If you are using another operating system, you can configure the TA using the firmware- based configuration utility or AT commands. Procedures for using the firmware-based configuration utility and AT commands are described in Appendix E.
Before you begin, verify your switch type and TEI with your local ISDN provider and have that information readily available

Do you want the wizard to search for your ISDN TA? with the Yes option enabled. Click Nextto continue.
Configuration Utilities


Click Next to continue.

From the Setup pull down window you can choose Express (Existing), Custom (Existing), or Custom (New). The Express (Existing) opens an existing configuration, allowing you to modify some elements of the configuration. Custom (Existing) opens an existing configuration, allowing you to modify all elements of the configuration. Custom (New) allows you to customize a new configuration.
I have chosen Custom (New) for this example.
Configuration Utilities


Select the network switch type you listed in the Before You Start section of this chapter.

Click Next to continue.
Configuration Utilities


The TEI is a unique number assigned to the TA at subscription time. The TEI is used by the telephone central office (CO) to identify the various TAs connected to the ISDN network. The TEI number can be fixed (range 0 - 63) or dynamic and is assigned automatically at the CO each time the TA connects to the ISDN interface and powers up.
Click Next when you are finished.

Configuration Utilities

SPID is only used in North America. A SPID is the ISDN network parameter for local terminal identification and tracking. A SPID is assigned by your local ISDN provider when you subscribe, they are in the form of a string of up to 20 characters. A SPID points to a specific location in the provider’s central office memory where service and feature parameters are stored.
Click Next when you have entered your SPID information.

Call Control Setup allows you to set up your terminal adapter and customize how it dials and answers. You can configure persistent DTR dialing, calling line identification, auto answer data calls, and number of rings. You can also set the online inactivity timer as well as the dialing method.
Click Next when you are done.
Configuration Utilities


If you would like the TA to detect the data protocol of an incoming data call and automatically change the TA’s protocol to match the incoming call, click auto protocol detection check box. Click Next to continue.

You can store up to ten phone numbers with up to 25 characters per number. Stored number zero is used if Persistent DTR Dialing is enabled in Call Control Setup screen.
Configuration Utilities


Click Next when you have finished entering your settings.

Click Next when you are finished.
Configuration Utilities


When your selections are complete, click Next.

You can enter any name up to 35 characters or less in the Store Configuration as: window. Click Next after you have selected a name.
Configuration Utilities



When the Finish button becomes active, click Finish.
Configuration Utilities

AT Commands, S-Registers, and Result Codes
Chapter 4: A er 4: A er 4: A er 4: A er 4: AT C T C T C T C T Commands, S-R ommands, S-R ommands, S-R ommands, S-R ommands, S-Registers, and R ers, and R ers, and R ers, and R ers, and Result C esult C esult C esult C esult Codes
All references to “TA” in this chapter refer to the MTA128ST/NT. This chapter also assumes knowledge of issuing AT commands. refers to the carriage return character (typically generated by pressing the ENTER or RETURN key on the keyboard).
For command execution details see the additional documents on this CD.
The TA’s command buffer can store 80 characters, including spaces and other characters used in telephone numbers. If you mistype a command string, you can edit it by using the backspace or the delete key, but only before you press <CR>. As you type a command string, it appears on your monitor screen, letting you verify your input as you type it. The table below lists the AT commands recognized by the TA.
If your MTA128ST/NT is connected to a computer terminal, you can send AT commands to the MTA128ST/ NT by entering them on the keyboard. If your MTA128ST/NT is connected to a computer, you can send AT commands to the MTA128ST/NT by typing them in the terminal window of a data communications program such as HyperTerminal. You can also send some AT commands indirectly by configuring your data communications program.
To enter AT commands, use the following format: AT <command string> <cr>. The characters AT cause the MTA128ST/NT to interpret the following string as a command. The command string consists of one or more commands. The carriage return character, , sends the command string to the MTA128ST/NT. If you are entering a command string in your communication program’s terminal window, insert the carriage return character by pressing the ENTER key on your keyboard. If configuring a communications program, you typically must insert the carriage return character by adding ^M to the end of the command string.
The MTA128ST/NT has three modes of operation: offline command mode (the default state), online command mode, and data mode. The MTA128ST/NT responds to AT commands only when it is in one of the command modes. After the MTA128ST/NT establishes a connection and goes online in data mode, it interprets any further characters you enter as data rather than as commands and transmits them to the remote device.
When the MTA128ST is in data mode, you can switch it to online command mode by sending it an escape sequence. The MTA128ST/NT responds to two types of escape sequences:
The MTA128ST/NT’s command buffer can store 80 characters, including spaces and other characters used in telephone numbers. If you mistype a command string, edit it by using the backspace or the delete key but only before you press ENTER. As you type a command string, it appears on your monitor screen, letting you verify your input as you type it.
The AT commands recognized by the MTA128ST/NT are listed by function in this chapter first in an abbreviated list. For an alphabetical list of AT commands, see the AT commands documents on the CD included with this product.
Command Execution

AT Commands, S-Registers, and Result Codes
AT Attention code A/ Repeat AT Command Return or Enter Command execution +++AT In-band escape code AT Out-of-band escape code
General Information Commands In Display Product Information Ln List Active Profile Information !L Display Network Configuration >MIBn Management Information Block (MIB) Information
Network Configuration Commands **s User-User Information Element String %A97=n Dialing Method >A0=n Type of Coding !C0=n Network Switch Type !C6=n Data SPID *!C6=n Voice SPID !D0=n V.120 LLC Information Element !D1=n V.110 BC Information Element (some models only) !D3=n SAPI-0 Data TEI *!D3=n SAPI-0 Voice TEI !DNn Disable Data DN/MSN n *!DNn Disable Voice DN/MSN n !ENn Enable Data DN/MSN n *!ENn Enable Voice DN/MSN n >MULT=N Multi-point setting !Nn=s Data DN/MSN n *!Nn=s Voice DN/MSN n
Serial Port Configuration Commands &Cn DCD (Data Carrier Detect) Control &Dn DTR (Data Terminal Ready) Control $Dn Persistent DTR Dialing &En Flow Control &Mn Asynchronous Mode $MBn V.110 Network Rate (some models only) @P3=n Parity @P4=n Data Bits @P6=n Stop Bits &Rn CTS (Clear To Send) Control &RFn CTS/RTS Interaction Control &Sn DSR (Data Set Ready) Control $SBn Serial Port Speed %Sn Serial Port Mode #Xn Send Multiple Xoff Characters
General Configuration Commands @CONFIG Configuration Menu

AT Commands, S-Registers, and Result Codes
En Command Mode Echo %En Escape Sequence Options &Fn Load Factory Profile %Mn Management Mode Qn Quiet Mode Sr=n Set S-register Sr? Read S-register Vn Verbose Result Codes &Wn Store Active Profile Xn Connect Messages Z Reset to Stored Profile &Zn= Store Telephone Number !Z=n Rate Adaptation/Data Protocol
Digital (Data) Call Commands A Answer Digital Call Dn Dial Digital Number DSn Dial Stored Number Hn Hang up Digital Call !Hn Digital Call Hold-off Time &Jn Channel Bundling O Return Online
Analog (POTS) Call Commands *An Answer Analog Call *Bn Send Analog Dial Digit *Dn Dial Analog Number *Hn Hang up Analog Call *!Hn Analog Call Hold-off Time !RXGn POTS Port Receive Gain !TXGn POTS Port Transmit Gain

AT Commands, S-Registers, and Result Codes
S-registers are sections of memory in which values are stored that affect how the TA operates. S-registers are so-called because each has a name that begins with the character S. Use the Sr=n command to assign a value to an S-register or use the Sr? command to read the current value of an S-register. S- registers are stored in non-volatile RAM (NVRAM) by using the &W0 command. ATZ<CR> restores S- registers to values stored in NVRAM if any were stored using the &W0 command, otherwise they revert to factory default settings in ROM. Table 4-2 summarizes the available S-registers and their function.
See the additional documents on this CD for more information on each S register.
S-Register Function S0 Rings Until Answer S1 Ring Count S2 Escape Character S3 Carriage Return Character S4 Line Feed Character S5 Backspace Character S7 Wait for Connection (Abort Timer) S8 Pause Time for Comma S10 DCD Drop Time S25 DTR Drop Time S26 Delay DTR Monitoring After Connect S27 RS-232 CLEAR Synchronization Sequence S29 On-line Inactivity Timer Period S30 On-line Inactivity Timer S31 Maximum Re-dial Timeout Value S32 Escape Sequence Timeout S34 Maximum Escape Sequence Length S44 POTS Port Ring Frequency S45 Use Dial Tone From Central Office S46 Pulse-Dial Recognition S49 POTS Port Dial Tone Gain S50 Caller Line ID (CLI) S51 POTS Port Dial Tone Suppression S52 Auto-Protocol Detection S53 Maximum X.75 Buffer Size S54 Force 56Kbps B-Channel Data Rate S55 Information Transfer Capability for POTS Port Calls S56 Calling Party Number Information Element Settings S57 Called Party Number Information Element Settings S58 Client-side PPP/ML-PPP Authentication Protocol Negotiation S59 Dynamic Bandwidth Allocation (DBA) Scheme S60 Bandwidth-On-Demand (BOD) High Threshold Sampling Period S61 Bandwidth-On-Demand (BOD) High Throughput Threshold S62 Bandwidth-On-Demand (BOD) Low Threshold Sampling Period

AT Commands, S-Registers, and Result Codes
S63 Bandwidth-On-Demand (BOD) Low Throughput Threshold S64 Call Bumping (CB) S65 POTS Call Bump Forwarding Delay S66 Country Selections for POTS Ring Signal S67 Single or Dual Cadence POTS Ring Signal S68 POTS Ring Signal First Active Duration S69 POTS Ring Signal First Idle Duration S70 POTS Ring Signal Second Active Duration S71 POTS Ring Signal Second Idle Duration S73 MultiLink Endpoint Discriminator Type S74 Maximum CLEAR Buffer Size S75 Maximum V.110 Buffer Size* (ST only) S76 V.110 Network Rate* (ST only) S77 V.110 Network Rate Control* (ST only) S80 Persistent DTR Dialing Delay S81 Link Setup Timeout S82 Delay Before Trying V.110* S84 Data to Terminal Delay S85 Data to B-channel Delay S86 V.110 T1 Time-out* S87 INS64 Analog Call Origination Delay S154 B-Channel Answer Rate * Note: V.110 is supported by some MTA128ST models only.

AT Commands, S-Registers, and Result Codes
When the MTA128ST/NT receives an AT command from the computer or terminal, it attempts to execute the command, then sends a status message to the computer or terminal that reports the result of the command. The MTA128ST/NT provides you with several of these response messages, or result codes, which can be displayed on your monitor or intercepted and used by your communications software. Using the V command, you can select whether the result codes are terse (numbers) or verbose (words).
The MTA128ST/NT’s result codes are listed below. Note that the speed of an ISDN channel is always either 56 Kbps or 64 Kbps. Connect messages indicate the speed of the connection between the MTA128ST/NT and your computer or terminal.
TERSE VERBOSE DEFINITION 0 OK TA executed the command without error 1 CONNECT TA established an ISDN connection 2 RING TA detected a ring caused by incoming call 3 NO CARRIER TA did not detect carrier within time allotted by register S7 4 ERROR Error in the AT command 5 CONNECT 1200 TA connected at 1200 bps 6 NO DIALTONE TA has a poor connection to ISDN network 7 BUSY TA detected a busy signal 8 CONNECT 300 TA connected at 300 bps 9 CONNECT 600 TA connected at 600 bps 10 CONNECT 2400 TA connected at 2400 bps 11 CONNECT 4800 TA connected at 4800 bps 12 CONNECT 9600 TA connected at 9600 bps 14 CONNECT 19200 TA connected at 19200 bps 17 CONNECT 56000 TA connected at 56000 bps 18 CONNECT 57600 TA connected at 57600 bps 19 CONNECT 64000 TA connected at 64000 bps 28 CONNECT 38400 TA connected at 38400 bps 79 PPPC PROTOCOL TA using Point-to-Point protocol 80 HDLC PROTOCOL TA using raw HDLC mode 82 V.110 PROTOCOL TA using V.110 rate adaption protocol (Note: V.110 is supported on some MTA128ST models only.) 83 V.120 PROTOCOL TA using V.120 rate adaption protocol 84 X.75 PROTOCOL TA using X.75 rate adaption protocol 87 CLEAR PROTOCOL TA using CLEAR (transparent) protocol
You can configure and operate the MTA128ST/NT entirely with AT commands if you like. But remember, you can issue AT commands only from a terminal or from a computer running a communications program in terminal mode. This section describes how to use AT commands for basic operations, such as calling, answering a call, and hanging up.
The MTA128ST/NT has three modes of operation. They are:
Modes of Operation

AT Commands, S-Registers, and Result Codes
Before you can place a data call, configure the MTA128ST/NT for the local switch type, serial port speed, and the data type of the ISDN device you want to call. See Chapter 3, Configuration Utilities.
To dial a number using AT commands, you must first start a data communications program. In the program’s terminal mode, type ATDxxxxxxx<cr>, where xxxxxxx is the telephone number you want to dial, and is the carriage return character that is sent when you press the ENTER key, such as ATD7853500<cr>. The dial string can contain up to 80 characters.
To place an ML-PPP call, use an ampersand character (&) to join two telephone numbers, such as ATD7853500&7853502<cr>. The telephone numbers can be the same or different. Using this method, two B-channels are activated to transmit data at an aggregate speed of 128 Kbps.
To make it easier to read the dial string, you can use hyphens, spaces or parentheses. These characters are ignored by the MTA128ST/NT. For example, the MTA128ST/NT would read the following dial strings the same way:
ATD17637853500 <cr> ATD 1-763-785-3500 <cr> ATD 1 (763) 785-3500 <cr>
Channel Bundling Flag Dialing
The command AT&Jn is used to indicate whether outgoing calls should be made on two B-channels by default. The command AT&J1&W0, configures the TA to place a call, dialing on two B-channels by default. If no second number is given in the dial string, that single number is dialed twice. This compensates for the interworking issues with Windows Dial-Up Networking. On the other hand, if the user explicitly indicates two numbers in the dial string, then two numbers are dialed (e.g., ATD7853500&785 3502<cr>). The command AT&J0&W0, disables automatic call bundling. Note other valid characters joining two telephone numbers include a plus sign (+), and an exclamation mark (!).
Note: In Windows Dial-Up Networking, if the Use Country Code and Area Code box is checked in the Properties window for dial-up connection, the bundling modifier (i.e., &, + or !) is removed from the dialing string when the user attempts to make a connection. The solution is to not check the Use Country Code and Area Code box or to simply add the bundling dial modifier to the phone number at the time of connection.
To cancel a call before the MTA128ST/NT makes a connection, press any key.
Storing a Telephone Number
To store a telephone number, type &Zn=x in terminal mode, where n is the number of the memory register in which the number is to be stored, and x is the dial command string that you want to store. For example, type AT&Z9=763-785-3500 <cr> to store the number 763-785-3500 in memory register 9.
Dialing a Stored Telephone Number
To dial a stored telephone number, type DSn in terminal mode, where n is the location of the number you wish to dial. For example, type ATDS3 <cr> dials a telephone stored in memory register 3 location.
Dialing · Canceling a Call

AT Commands, S-Registers, and Result Codes
Displaying a Stored Number
To display a stored telephone number, type &Zn? in terminal mode, where n is the memory register in which the number is stored. For example, type AT&Z5? <cr> to display the telephone number in memory register 5. To list all ten telephone numbers stored in memory, type ATL <cr>.
You can answer incoming calls to the MTA128ST/NT either manually or automatically. When the TA detects an incoming call, it turns on the RI signal on the V.24 interface and sends a RING result code to the computer or terminal after each ring. If autoanswer is enabled, the TA automatically answers the call. You can manually answer the call with the A command. Both methods are described below.
If your communication program is in terminal mode when the RING result code appears on your monitor, you can manually answer the call by typing ATA <cr>.
To cause the MTA128ST/NT to automatically answer a call:
The TA answers the call after the number of rings specified by S0. To disable autoanswer, use a configuration utility or the command S0=0.
To hang up a call, escape to online command mode (+++AT<cr>), then enter the H command (ATH<cr>). The escape sequence and hang up command can be combined into one command string: +++ATH<cr>.
Answering Manually · Answering Automatically

Chapter 5: T er 5: T er 5: T er 5: T er 5: Troubleshooting
This chapter describes basic problems you may run into with your MTA128ST/NT and how to solve them. Your MTA128ST/NT was thoroughly tested at the factory before it was shipped. If you are unable to make a successful connection, or if you experience data loss during your connection, it is possible that the MTA128ST/NT is defective. However, it is more likely that the source of your problem lies elsewhere. Problems you may encounter include the following:
If you experience problems, please check the following possibilities before calling Tech Support (see Chapter 7).
SITUATION 1: The !Hn and *!Hn commands can be very useful for certain RAS environments that require at least 1 second to initialize a port after a call has disconnected (such as Citrix and Novell). For example, when a call disconnects, Citrix and Novell will begin initializing the port that just disconnected. However, it typically takes more than 1 second and during that time a call may be received by the digital or analog port. When this happens, Citrix and Novell do not answer the call nor do they finish the initialization process. To prevent this problem, setting !H5 and/or *!H5 will set the TA to hold of digital and/or analog calls for 5 seconds after the respective port(s) disconnect(s). This should give enough time for the digital and/or analog port to be initialized by Citrix or Novell and enter the “waiting for a call” state.
SITUATION 2: The autobauding code cannot differentiate between 7 data bits, no parity, 1 or 2 stop bits (7N1 or 7N2) and 7 data bits, mark parity, 1 or 2 stop bits (7M1 or 7M2). The TA assumes 7 data bits, mark parity, 1 stop bit (7M1) and this case covers 7N1, 7N2, 7M1 and 7M2. However, if for some reason the assumption of 7M1 causes a problem, then there is a workaround. The addition of the %S3 command and use of $SBn, @P3=n, @P4=n, and @P6=n will help work around this limitation. See the description for the %Sn command.
SITUATION 3: The autobauding code cannot differentiate between 8 data bits, no parity, 1 or 2 stop bits (8N1 or 8N2) and 7 data bits, space parity, 1 or 2 stop bits (7S1 or 7S2). The TA assumes 8 data bits, no parity, 1 stop bit (8N1) and this setting covers 7S1, 7S2, 8N1 and 8N2. However, if for some reason the assumption of 8N1 causes a problem, then there is a workaround. The addition of the %S3 command and use of $SBn, @P3=n, @P4=n, and @P6=n will help work around this limitation. See the description for the %Sn command.
Troubleshooting

SITUATION 4: The autobauding code does not report the number of stop bits. This may become a problem if the terminal is expecting a certain number of stop bits. The addition of the %S3 command and use of $SBn, @P3=n, @P4=n, and @P6=n will help work around this limitation. See the description for the %Sn command.
The AT commands in this section can be used in attempting to troubleshoot or debug a current problem. Some commands may be enhanced or limited by the debugging/logging/troubleshooting S-registers. For complete descriptions of the commands and S-registers, see the additional documents on this CD.
>Dn Embedded Protocol Analyzer (EPA) *FSn Reset TA *Ln Fatal Error Information >LOG Display Logging Buffer Contents >Sn Logging Variables >TIME Display Current Timestamp *V Various State Information
The S-registers in this section can be used in attempting to troubleshoot, debug, or even correct a current problem. Some S-registers modify functionality of various features. Some S-registers modify the functionality of the debugging/logging/troubleshooting commands described in the additional documents on the system CD.
S47 Pulse-dial Maximum Break Pulse Period S48 Pulse-dial Maximum Interdigital Pause S72 EuroISDN Variant S78 Maximum Allowed V.110 Network Rate (some models only) S90 Local PPP Capabilities S91 Remote PPP Capabilities S92 Channel ID Information Element Octet 3 Settings S93 Blacklisting S94 Minimum Buffer Space After Trigger S95 Logging Buffer Functionality S96 Decode (EPA) Buffer Functionality S98 ISDN_MSG Size S99 Startup Options S100 Flow Control High Threshold S101 Flow Control Low Threshold S102 Data to Save for Decoding

When you turn on the MTA128ST/NT, the LED indicators on the front panel should flash briefly as the TA runs a self-test. If the LEDs remain off, the TA probably is not receiving power.
The MTA128ST/NT does not respond to commands
Troubleshooting

To look for address or IRQ conflicts, select File, Run in Program Manager, type MSD, and press ENTER. Then select Mouse, COM Ports, and IRQ Status and note the addresses and IRQs that are in use. If you find an IRQ conflict, note which IRQs are not being used, then change one of the conflicting devices to use one of the unused IRQs. If you find an address conflict, change the address of one of the conflicting devices.
To change a port address or IRQ, double-click the Control Panel icon, then the Ports icon. Click on the port you want to change, click Settings, click Advanced, and select the new port address and/or interrupt. If you wish to use COM3 or COM4, note that COM3 shares an IRQ with COM1, as does COM4 with COM2, so you should change their IRQs to unused ones, if possible.
Right-click on My Computer, select Properties from the menu, click on the Device Manager tab, double- click on Ports, then double-click on the Communications Port your MTA128ST/NT is connected to. In the port’s Properties sheet, click on the Resources tab to see the port’s Input/Output range and Interrupt Request. If another device is using the same address range or IRQ, it will appear in the Conflicting Device List. Uncheck Use Automatic Settings to change the port’s settings so they do not conflict with the other device, or select the port the conflicting device is on and change it instead. If you need to open your computer to change switches or jumpers on the conflicting device, refer to the device’s documentation.
The MTA128ST/NT dials but cannot make a connection
There can be several reasons the MTA128ST/NT fails to make a connection. Possibilities include
Troubleshooting

You can place data calls but not voice calls or vice versa
You cannot place two simultaneous data calls
Note: In Windows 98/NT/ME, if the Use Country Code and Area Code box is checked in the Properties window for dial-up connection, the bundling modifier (i.e., &, + or !) is removed from the dialing string when the user attempts to make a connection. The solution is not to check the Use Country Code and Area Code box or to simply add the bundling dial modifier to the phone number at the time of connection.
The MTA128ST/NT disconnects while online
The MTA128ST/NT cannot connect when answering
Note: If the user wishes to accept calls while DTR is low, the MTA128ST/NT must be configured to ignore DTR. This is accomplished by entering AT&D0. With this configuration, the MTA128ST/NT is able to accept calls while DTR is low. If this configuration setting is not made, the TA rejects incoming calls until DTR is high while the calls comes in.
Troubleshooting

File transfer appears slower than it should be
Data is being lost
Garbage characters appear on the monitor
Your computer and the remote computer may be set to different parities. Check with the remote system and set your communications software to use the same parity as the remote system.
Making a V.120 call, caller gets a NO CARRIER message after dialing the number.
Some switches don’t support ISDN SETUP messages that contain a LLC (low layer compatibility) element. When these switches receive an LLC in the SETUP, they immediately reject the call and a NO CARRIER message displays. Disable LLC for V.120 calls by issuing the command AT!D0=0. To enable LLC again for V.120 calls, issue the command AT!D0=1 (the default setting).
Making a V.110 call, caller gets a NO CARRIER message after dialing the number.
Some switches don’t support extended BC (bearer capability) information in the ISDN SETUP message, such as the one normally sent by V.110 data protocol. When these switches receive a BC with extended capability information in the SETUP, they immediately reject the call and a NO CARRIER message displays. Disable sending extended BC information for V.110 calls by issuing the command AT!D1=0. To enable sending extended BC information for V.110 calls, issue the command AT!D1=1 (the default setting). Note: V.110 is supported on some MTA128ST models only.
When using X.75 data protocol to transfer data via the Zmodem, the Zmodem displays Intermittent bad packet errors and data throughput drops.
This occurs in cases when the X.75 packet size is greater than 1024 bytes and the terminal adapter sending the file has a fast serial baud rate (e.g., 115200 bps) and the terminal adapter receiving the file has a slow serial baud rate (e.g., 19200 bps). To reduce or possibly eliminate this, reduce the X.75 packet size (S53) to a value less than or equal to 102 bytes (e.g., ATS53=512). However, if you set the receiving terminal adapter’s serial baud rate nearly equal to or greater than the serial baud rate of the sending terminal adapter, then the packet size can be greater than 1024, and Zmodem transfers the data without bad packet errors.
The MTA128ST/NT won’t accept V.120 calls from a 3Com Impact IQ terminal adapter. The Impact IQ displays a connected status, but the MTA128ST/NT does not.
The MTA128ST/NT is looking for a SABME command from the Impact IQ to finish establishing the V.120 connection. However, the Impact IQ won’t send a SABME until it has data to send. Have the Impact IQ send a character by pressing any key (such as the space bar) on the terminal attached to the Impact IQ. The MTA128ST/NT responds with a CONNECT message and displays the key you pressed (e.g., a space).
MTA128ST/NT receives garbage characters when connected to a 3Com Impact IQ terminal adapter.
Most likely, the Impact IQ has compression turned on. The compression used by the Impact IQ is incompatible with the compression used by the MTA128ST/NT. Disconnect the data connection and give the Impact IQ the command AT%CO and then establish the data connection again. The garbage characters should disappear.
Troubleshooting

The MTA128ST/NT receives garbage characters after receiving several good characters when connected to a 3Com Sonix adapter.
Most likely, the Sonix has compression turned on. The compression used by the Sonix is incompatible with the compression used by the MTA128ST/NT. Disconnect the data connection and the give the Sonix the command AT”HO (that’s a double quote) and then establish the data connection again. The garbage characters should disappear.
Each time a 3Com Sonix terminal adapter originates a V.120 call, the MTA128ST answers the call as a V.110 call.
The Sonix sends V.110 information in the SETUP message to the network. Since the MTA128ST’s default is with Auto Protocol Detection enabled (ATS52=1), it looks at SETUP information from the Sonix and determines erroneously that it is a V.110 call. Disable Auto Protocol Detection in the MTA128ST with the command ATS52=0 and try the connection again.
The MTA128ST/NT won’t connect to an ELSA terminal adapter with the V.120 data protocol.
Most likely, the ELSA terminal adapter has compression turned on. The compression used by the ELSA terminal adapter is incompatible with compression used by the MTA128ST/NT. Give the ELSA the command AT%CO to disable compression and try again.
The IWay Hopper works with all Macintosh models with a serial port. Some models may require a USB-to- serial adapter since the MTA128ST/NT is a serial RS-232 device. Scripts are provided for Mac OS 8 through Mac OS X. These scripts also work with Mac OS 7.x with the Apple Internet Connection Kit installed. (OS 8 and 8.1 have the Apple Internet Connection Kit built-in and Mac OS 8.5 through Mac OS X have Internet connection capabilities built-in.) If you don’t use the Internet connection abilities provided by the Mac OS, then you will need to create your own initialization string to suit your needs. Generally, these initialization strings can be based on the Factory Profile command &Fn to set up the desired protocol.
Troubleshooting

Chapter 6: P er 6: P er 6: P er 6: P er 6: Point-to-Point C oint C oint C oint C oint Communications: PPP/MLPPP ations: PPP/MLPPP ations: PPP/MLPPP ations: PPP/MLPPP ations: PPP/MLPPP
You can use the &, ! and + characters to bond two channels together when performing channel bonding (available only with the MLPPP protocol).
When you use the &, +, or ! characters with the MLPPP protocol, the TA regards the number following that character as a second phone number. When used with MLPPP, the TA first dials the number given before the &, +, or ! character. After establishing the LCP (Link Control Protocol) and authenticating (if requested), the TA dials the second number (the number after the &, +, or ! character).
This is an alternative method to set up a MultiLink PPP call as opposed to using the &J1 command, which dials the given number twice rather than dialing two different numbers. Example: ATD5551000&5553000 dials 5551000 first, sets up the LCP and authenticates, and then dials 5553000 and sets up the LCP and authenticates on the second B-channel (thus setting up an MLPPP call).
Making a PPP or MLPPP connection is not as simple as using a terminal emulation program and dialing one or two phone numbers. Using the PPP data protocol provided by the TA (!Z=9) requires that the TA receives PPP-formatted data from the terminal. If the TA does not receive PPP-formatted data, the data is discarded by the TA and never sent to the peer. The TA can receive PPP-formatted data from the peer and send it to the terminal, but if it is sending the data to a terminal emulation program running on the terminal, the data appears as garbage.
The PPP data protocol requires PPP data to be sent from the terminal in order for the data to be sent to the other side. The MultiLink protocol requires the PPP protocol to establish itself on one B-channel before the second channel is dialed. The LCP can be established only if data is sent by the terminal to the TA. Negotiation actually occurs between the local terminal and the remote peer. The TA simply views the negotiation, so it knows how to negotiate on the second B-channel. When the second B-channel connects, the local terminal is unaware and doesn’t participate in the LCP negotiation. Therefore, the TA must mimic the negotiation that was witnessed on the first channel.
For example, sending ATDT5551000&5553000 from a terminal emulation program to the TA does NOT cause the TA to dial two channels and bring up the 128K LED. However, if that dial command was given by Windows Dial-Up Networking, for example, then there is a chance that the TA dials two channels and brings up the 128K LED if the user name and password are correct, if the IP address is okay, and if the peer allows a MultiLink connection. If MultiLink is not allowed, then the TA uses one channel for the PPP connection. If the user name or password are invalid or incorrect, the connection is terminated. If an IP address is in conflict, the connection is terminated as well.
Software applications that can format PPP Data for Microsoft-compatible PCs include Windows Dial-Up Networking (DUN) and WinSock.
Software applications that can format PPP Data for Apple Macintoshes include OT/PPP, MacPPP, FreePPP, GearBox, and pppd via Internet Connect (Mac OS X).
Dynamic Bandwidth Allocation (DBA) supports the addition and removal of data channels according to the level of throughput through the TA and according to analog POTS port use.
If throughput is above a given threshold, a second data channel is added to facilitate higher throughput.

If throughput drops below a given threshold, the second channel is removed to save the cost of having the second B-channel active but not fully used.
If an outgoing analog call is desired or there is an incoming analog call, a data channel can be bumped (removed) to allow analog POTS port use.
Bandwidth-on-Demand (BOD) checks the data throughput to determine whether a channel should be added or removed.
Call Bumping (CB) determines whether a channel needs to be added again (analog call disconnected) or removed (incoming or outgoing analog call desired) due to activity on the analog POTS port.
To activate Bandwidth-on-Demand or Call Bumping, enable Dynamic Bandwidth Allocation in S-register S59.
The 128 LED flashes if DBA is active and only one data channel is connected. The 128 LED stops flashing and remains on after the second B-channel is successfully added. If the second channel is disconnected due to low throughput or a call-bump, the 128 LED flashes again to indicate that DBA is still active.
If the TA attempts to add a B-channel, but the host is busy or not answering, the TA starts a timer (time is set in S-register S31). However, if the analog device goes off-hook or an analog call is received, the timer is stopped and reset. After the analog call finishes, the TA again attempts to add the B-channel. Taking the analog device off-hook and placing it on-hook again interrupts the timer, thus allowing control over the amount of time it takes before attempting to add the second channel (rather than waiting for timeout values specified by S31).
MLPPP is the only data protocol that currently supports DBA. To start DBA, set &J1 or give two numbers to be dialed. Otherwise, the TA will not negotiate the MultiLink Protocol (MP) option. If the MultiLink Protocol option is not negotiated, Dynamic Bandwidth Allocation is not possible.
DBA Features:
Bandwidth-on-Demand (BOD)—S60, S61, S62, and S63
– Divide the total number of bits received from the PC (not including start, stop, or parity bits) during the
High Threshold Sampling Period (S60) by the High Threshold Sampling Period (S60) value (in Kbps).
Total bits received ÷ S60 = High Throughput Average
– Or, divide the total number of bits transmitted to the PC (don’t include start, stop, or parity bits) during
the High Threshold Sampling Period (S60) by the High Threshold Sampling Period (S60) value (in Kbps).
Total bits transmitted ÷ S60 = High Throughput Average
If the average (transmitted or received) exceeds the High Threshold (S61) and only one data channel is active and the second B-channel is not already in use, the TA attempts to add a second data channel.
– Divide total number of bits received from the PC (not including start, stop, or parity bits) during the
Low Threshold Sampling Period (S62) by the Low Threshold Sampling Period (S62) value (in Kbps).
Total bits received ÷ S62 = Low Throughput Average
– Or, divide total number of bits transmitted to the PC (not including start, stop, or parity bits) during the
Low Threshold Sampling Period (S62) by the Low Threshold Sampling Period (S62) value (in Kbps).
Total bits transmitted ÷ S62 = Low Throughput Average
If either average (transmitted or received) equals or is less than the Low Threshold (S63) and there are two active data channels, the TA disconnects the second data channel.
DBA Data Protocols

– increase the High Threshold Sampling Period (S60) and the Low Threshold Sampling Period (S62) and – decrease the Low Throughput Threshold (S63).
Call Bumping (S-register S64)

Warranty, Service, and Technical Support
Chapter 7: W er 7: W er 7: W er 7: W er 7: Warranty, S, Sererererervic vicvic vic vice, and T e, and T e, and T e, and T e, and Tech S ech S ech S ech S ech Suppororororort
Warranty
Multi-Tech Systems, Inc., (hereafter “MTS”) warrants that its products will be free from defects in material or workmanship for a period of two, five, or ten years (depending on model) from date of purchase, or if proof of purchase is not provided, two, five, or ten years (depending on model) from date of shipment.
MTS MAKES NO OTHER WARRANTY, EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.
This warranty does not apply to any products which have been damaged by lightning storms, water, or power surges or which have been neglected, altered, abused, used for a purpose other than the one for which they were manufactured, repaired by Customer or any party without MTS’s written authorization, or used in any manner inconsistent with MTS’s instructions.
MTS’s entire obligation under this warranty shall be limited (at MTS’s option) to repair or replacement of any products which prove to be defective within the warranty period or, at MTS’s option, issuance of a refund of the purchase price. Defective products must be returned by Customer to MTS’s factory – transportation prepaid.
MTS WILL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES, AND UNDER NO CIRCUMSTANCES WILL ITS LIABILITY EXCEED THE PRICE FOR DEFECTIVE PRODUCTS.
In the event that service is required, products may be shipped, freight prepaid, to our Mounds View, Minnesota factory:
Multi-Tech Systems, Inc.
Mounds View, MN 55112
A Returned Materials Authorization (RMA) is not required. Return shipping charges (surface) will be paid by MTS.
Please include, inside the shipping box, a description of the problem, a return shipping address (must have street address, not P.O. Box), your telephone number, and if the product is out of warranty, a check or purchase order for repair charges.
For out of warranty repair charges, go to www.multitech.com/documents/warranties
Extended two-year overnight replacement service agreements are available for selected products. Please call MTS at (888) 288-5470, extension 5308 or visit our web site at
http://www.multitech.com/programs/orc/ for details on rates and coverage’s.
Please direct your questions regarding technical matters, product configuration, verification that the product is defective, etc., to our Technical Support department at (800) 972-2439 or email tsupport@multitech.com. Please direct your questions regarding repair expediting, receiving, shipping, billing, etc., to our Repair Accounting department at (800) 328-9717 or (763) 717-5631, or email mtsrepair@multitech.com.
Repairs for damages caused by lightning storms, water, power surges, incorrect installation, physical abuse, or user-caused damages are billed on a time-plus-materials basis.
2205 Woodale Drive

Warranty, Service, and Technical Support
Your original point of purchase Reseller may offer the quickest and most economical repair option for your Multi-Tech product. You may also contact any Multi-Tech sales office for information about the nearest distributor or other repair service for your Multi-Tech product.
http://www.multitech.com/COMPANY/offices/DEFAULT.ASP
In the event that factory service is required, products may be shipped, freight prepaid to our Mounds View, Minnesota factory. Recommended international shipment methods are via Federal Express, UPS or DHL courier services, or by airmail parcel post; shipments made by any other method will be refused. A Returned Materials Authorization (RMA) is required for products shipped from outside the U.S.A. and Canada. Please contact us for return authorization and shipping instructions on any International shipments to the U.S.A. Please include, inside the shipping box, a description of the problem, a return shipping address (must have street address, not P.O. Box), your telephone number, and if the product is out of warranty, a check drawn on a U.S. bank or your company’s purchase order for repair charges. Repaired units shall be shipped freight collect, unless other arrangements are made in advance.
Please direct your questions regarding technical matters, product configuration, verification that the product is defective, etc., to our Technical Support department nearest you or email tsupport@multitech.com. When calling the U.S., please direct your questions regarding repair expediting, receiving, shipping, billing, etc., to our Repair Accounting department at
(763) 717-5631 in the U.S.A., or email mtsrepair@multitech.com.
Repairs for damages caused by lightning storms, water, power surges, incorrect installation, physical abuse, or user-caused damages are billed on a time-plus-materials basis.
Procedures for International Distributors of Multi-Tech products are on the distributor web site.
http://www.multitech.com/PARTNERS/login/
Copyright © Multi-Tech Systems, Inc. 2001 [appr. 9-10-01]
If you have access to the World Wide Web, you can register your Multi-Tech product online at
http://www.multitech.com/register/
In the event that service is required, products may be shipped, freight prepaid, to our Mounds View, Minnesota, factory:
Multi-Tech Systems, Inc.
Mounds View, MN 55112
A Returned Materials Authorization (RMA) is not required. Return shipping charges (surface) will be paid by MTS. Please include inside the shipping box a description of the problem, a return shipping address (must have street address, not P.O. Box), a telephone number, and if the product is out of warranty, a check or purchase order for repair charges.
For out of warranty repair charges, go to http://www.multitech.com/documents/warranties
Extended two-year overnight replacement agreements are available for selected products. Please call MTS at 888 288-5470, extension 5308, or visit our web site at http://www.multitech.com/PROGRAMS/orc/ for details on rates and coverages.
2205 Woodale Drive

Warranty, Service, and Technical Support
Please direct your questions regarding technical matters, product configuration, verification that the product is defective, etc., to our Technical Support department at 800 972-2439 or e-mail tsupport@multitech.com.
Please direct your questions regarding repair expediting, receiving, shipping, billing, etc., to our Repair Accounting department at 800 328-9717 or +763 785-3500, or e-mail mtsrepair@multitech.com.
Repairs for damages caused by lightning storms, water, power surges, incorrect installation, physical abuse, or user-caused damages are billed on a time-plus-materials basis.
Your original point of purchase reseller may offer the quickest and most economical repair option for your Multi-Tech product. You may also contact any Multi-Tech sales office for information about the nearest distributor or other repair service for your Multi-Tech product: http://www.multitech.com/COMPANY/offices/ DEFAULT.ASP.
In the event that factory service is required, products may be shipped, freight prepaid, to our Mounds View, Minnesota, factory. Recommended international shipment methods are via Federal Express, UPS or DHL courier services, or by airmail parcel post; shipments made by any other method will be refused. A Returned Materials Authorization (RMA) is required for products shipped from outside the U.S.A. and Canada. Please contact us for return authorization and shipping instructions on any international shipments to the U.S.A. Please include, inside the shipping box, a description of the problem, a return shipping address (must have street address, not P.O. Box), your telephone number, and if the product is out of warranty, a check drawn on a U.S. bank or your company’s purchase order for repair charges. Repaired units will be shipped freight collect, unless other arrangements are made in advance.
Please direct questions regarding technical matters, product configuration, verification that the product is defective, etc., to our Technical Support department nearest you, as listed at http://www.multitech.com/ COMPANY/offices/DEFAULT.ASP., or e-mail tsupport@multitech.com. When calling the U.S., please direct questions regarding repair expediting, receiving, shipping, billing, etc., to our Repair Accounting department at +763 717-5631 in the U.S.A., or e-mail mtsrepair@multitech.com.
Repairs for damages caused by lightning storms, water, power surges, incorrect installation, physical abuse, or user-caused damages are billed on a time-plus-materials basis.
Procedures for international distributors of Multi-Tech products are on the Distributor Web site at http:// www.multitech.com/PARTNERS/login/
SupplyNet, Inc., can supply you with replacement power supplies, cables and connectors for selected Multi-Tech products. You can place an order with SupplyNet via mail, phone, fax or the Internet at the following addresses:
Mail: SupplyNet, Inc. 614 Corporate Way Valley Cottage, NY 10989 Phone: 800 826-0279 Fax: 914 267-2420 Email: info@thesupplynet.com Internet: http://www.thesupplynet.com

Warranty, Service, and Technical Support
Multi-Tech Systems has an excellent staff of technical support personnel available to help you get the most out of your Multi-Tech product. If you have any questions about the operation of this unit, please call 800 972-2439 (USA and Canada) or 763 785-3500 (international and local). Please have modem information available. You can also contact Technical Support by e-mail at the following addresses:
U.K.: support@multitech.co.uk +(44) 118 959 7774
U.S.A., Canada tsupport@multitech.com 800 972-2439
Please note the status of the modem before contacting Technical Support. Status information can include the state of the LED indicators, screen messages, diagnostic test results, problems with a specific application, etc.
Country Email Telephone

Appendix A:C endix A:C endix A:C endix A:C endix A:Configuration P ation P ation P ation P ation Profofofofofiles
For quick setup, the MTA128ST/NT includes six Quick Setup Factory Profiles, each of which is configured for a specific type of port operation. You can load a Quick Setup Factory Profile into active memory by using the command &Fn, in which n is the number of the profile you wish to load. If you wish, you can then customize the profile and store it, using the &W command, so that it loads automatically when the MTA128ST/NT is turned on or reset. These profiles are stored in permanent memory and are not user- configurable as such.
&F0 Profile 0—Modem-like operation (default)
&F1 Profile 1—V.110 async operation
&F2 Profile 2—V.120 async operation
&F3 Profile 3—X.75 async operation
&F4 Profile 4—ML-PPP async operation
&F5 Profile 5—SoftBonding Asynchronous Operation
&F6 Profile 6—HDLC Asynchronous Operation
&F7 Profile 7—CLEAR operation
&F0 Profile 0–Modem-Like Asynchronous Operation
&F1 Profile 1–V.120 Asynchronous Operation
&F2 Profile 2–X.75 Asynchronous Operation
&F3 Profile 3–PPP Asynchronous Operation
&F4 Profile 4–SoftBonding Asynchronous Operation
&F5 Profile5–HDLC Asynchronous Operation
&F6 Profile 6–CLEAR Asynchronous Operation
The following procedure assumes that you want to load, modify, and store Quick Setup Factory Profile 2 as your default configuration.
Appendices

Appendix B: Or endix B: Or endix B: Or endix B: Or endix B: Ordering Y dering Y dering Y dering Y dering Your ISDN L our ISDN L our ISDN L our ISDN L our ISDN Line
There are two ways to specify your ISDN line configuration to your service provider. One is by using ISDN "ordering codes" in which the user, the Local Exchange Carrier (LEC) or Internet Service Provider (ISP) are using common nomenclature to describe elements of service. The other way of ordering service is to use a “building block approach”; where the naming conventions are non-standardized, and the user and provider must establish a set of provisioning options.
The first step in ordering (“provisioning”) an ISDN BRI line is to contact your LEC and verify ISDN BRI loop availability in your location. There is a distance limitation of approximately 2 miles (1800Kf) from the BRI loop. Each request for BRI is handled on a case-by-case basis. Once qualified, the LEC requires information on the type of equipment and protocol used. Most ISDN BRI is configured as “voice and data” (due to the fact that the LEC network is primarily analog, and ISDN digital technology converts the digital signal into analog, transports it over their analog lines, and then re-converts it into digital data at the other end) .
As a general procedure when ordering an ISDN BRI (2B+D) line:
Appendices

The options of Circuit Switch Voice Bearer (CSV) and Circuit Switch Data Bearer (CSD) are broad categories of Bearer Services that the phone companies can provide. Different bearer services provide different types of guarantees about the reliability and synchronization of the data. There are currently ten different bearer services for circuit-mode, and three services for packet mode.
These bearer services are defined in terms of a number of attributes, which include mode (circuit or packet), structure (bit-stream or octet-stream), transfer rate (e.g. 64Kbps), transfer capability (basically, the content, for instance speech, 7Khz audio, video, or unrestricted), and several other attributes that specify protocols to use and other things.
The attributes of the bearer service are encoded into a Bearer Code, or BC, that is sent everytime a new connection is being set up. In theory, this allows the switches to dynamically choose from a variety of different switching paths techniques depending on requirements. In practice, the SPID is used to determine what services are needed for switching, as this greatly simplifies things for the telephone companies. The Bearer Code will not be completely ignored, however there are certain bearer services that will be unavailable on your B-channels, based on how they are configured. It is important to note that the Bearer Code is sent to the switch every time a connection is established. However, the SPID is only sent to the switch when you physically attach your equipment to your phone line. At this time the switch gives your device a Terminal Equipment Identifier (TEI) which is used from then on to identify all connection requests from that piece of equipment. This allows the switch to look at the TEI and Bearer Code, determine the SPID, and see if the Bearer Code and the SPID match up.
An organization called ISDN Solutions Group, made up of ISDN service providers and equipment vendors, was formed to simplify the often complex task of ordering an ISDN line. This method, supported by most (but not all) service providers, uses ISDN ordering codes to define the ISDN line configuration. Your ISDN TA has been tested to operate with the following ordering codes: B1, Capability C, Capability R, I2, J2, J3, Capability S, and M5, as described in the following sections.
This ISDN line ordering code supports:
This ISDN line ordering code supports:
This ISDN ordering code supports:
Applications for Capability R include:
Appendices

This ISDN ordering code supports:
I2 is not available on the Northern Telecom switch. Two directory numbers are required for 2B operation; in this case use J2.
This ISDN ordering code supports:
This ISDN ordering code supports:
This ISDN ordering code is the recommended IOC since it supports the most features for voice and data applications. However, ISDN tariffs in some areas may warrant ordering codes with fewer features (e.g., where there is an additional monthly charge for having voice service on both B channels). If yours is a data only application, you may find Capability R more cost-effective.
Capability S supports:
This ISDN ordering code supports:
M5 is not available for services provided with Northern Telecom or AT&T switches. Since two directory numbers are required for 2B operation, use Capability S.
Appendices

This section guides you and your telephone company in specifying and obtaining ISDN service when IOCs are not used. To support most ISDN TA features, your telephone service must meet certain requirements. These requirements are described in the following sections. Some features may be added or deleted, depending on your actual data service needs and availability in your area. Before ordering, talk to your telephone company about which of the services listed on the following pages are provided in your area.
The following form was created for you to complete and fax to your telephone company to request the proper ISDN line for use with your ISDN TA module.
Name: Address:
Daytime Telephone Number:
___ 2B+D Service (supports up to 128K bps), or
___ 1B+D Service (supports up to 64K bps).
___ AT&T 5ESS, with:
___ 5E6 and later software, or
___ NI1 (National ISDN-1).
___ Northern Telecom DMS-100, with:
___ BCS-32 and later software (Pvc1), or
___ National ISDN-1 (Pvc2).
___ Siemens EWSD with National ISDN-1
Feature: Value B1 Service: DMD (On Demand) B2 Service: DMD (only if 2B+D ordered) Data Line Class: PM (Point-to-MultiPoint) Maximum B Channels: 2 (if 2B+D) or 1 (if 1B+D) Circuit Switched Voice (CSV) Bearer Channels: Any CSV Calls: 1 (recommended for test purposes) Number of Circuit Switched Data (CSD) Bearer Channels: Any Number of CSD Calls: 2 (if 2B+D ordered), or 1 (if 1B+D ordered) Terminal Type: Type A
Appendices Custom,

Turn these features OFF: Packet Mode Data MultiLine Hunt Multiple Call Appearances EKTS (Electronic Key Telephone Sets) Shared Directory Numbers Accept Special Type of Number Intercom Groups Modem Pools (Network Resource Selector) Message Waiting Hunting InterLATA Competition 5b. Northern Telecom DMS-100: request a point-to-multipoint line with:
10a. 5ESS Custom Line Additional Parameters
The AT&T 5ESS central office telephone switch supports a proprietary ISDN D-channel call control protocol called "Custom" which is based on CCITT recommendations. The ISDN TA configured for switch type AT&T 5ESS will work with lines providing this protocol on 5ESS switches with software version 5E6 or later.
The ISDN TA supports the following configurations on 5ESS Custom lines:
Appendices · permitted)

The requirements for the 5ESS line are shown below: B1 Service: DMD (On-demand)
Terminal Type Bearer Channels: Type A Multipoint lines require the phone company to create a SPID for each phone number on the line. With the exception of the ability to spread two calls across two phone numbers, multipoint lines offer no special features, and may create complications. However, if you use a multipoint line, the parameters are similar to the point-to-point lines, except for the SPIDs.
The 5ESS switch can provide a variety of supplementary features which the ISDN TA may not support. Enabling these features may have undesirable consequences.
Features to avoid are:
10b. DMS-100 Pvc1 Line Additional Parameters
The Northern Telecom DMS-100 telephone switch supports a proprietary ISDN D-channel call control protocol called Protocol Version 1 ("Pvc1") which is based on CCITT recommendations. The ISDN TA configured for switch type DMS-100 will work with lines providing this protocol on DMS-100 switches with software version BCS-32 or later.
The ISDN TA supports the following configurations on DMS-100 Custom lines:
The requirements for the DMS-100 multipoint line are defined in Local Interface Requirements, Local Service Requirements, and below. Fax this information to your local phone company.
The line should have two service profiles with the parameters below, to support BONDING and the POTS port, if installed.
Appendices

Appendices

Appendix C: FC endix C: FC endix C: FC endix C: FC endix C: FCC and C C and C C and C C and C C and Canadian R anadian R anadian R anadian R anadian Regulation
An FCC-compliant telephone cord and modular plug is provided with this equipment. This equipment is designed to be connected to the telephone network or premises wiring using a compatible modular jack which is Part 68 compliant. See installation instructions for details.
3. The ringer equivalence number (REN) is used to determine the quantity of devices which may be connected to the telephone line. Excessive REN’s on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the REN’s should not exceed five (5.0). To be certain of the number of devices that may be connected to the line, as determined by the total REN’s, contact the telephone company to determine the maximum REN for the calling area.
Manufacturer: Multi-Tech Systems, Inc. Model Number: MTA128NT FCC Registration #: AU7USA-24353-DD-N Ringer Equivalence:Modular Jack (USOC) RJ45/RJ11 Service Center in USA: Multi-Tech Systems Inc. 2205 Woodale Drive Mounds View, MN 55112 Voice (612) 785-3500/ FAX (612) 785-9874
Appendices

Notice: The ringer equivalence number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination of a interface may consist of any combination of devices subject only to the requirement that the sum of the ringer equivalence numbers of all the devices does not exceed 5. Notice: The Industry Canada label identifies certificated equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Industry Canada does not guarantee the equipment will operate to the user’s satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.
The CE mark is affixed to this product to confirm compliance with the following European Community Directives:
Council Directive 89/336/EEC of 3 May 1989 on the approximation of the laws of Member States relating to electromagnetic compatibility;
Council Directive 73/23/EEC of 19 February 1973 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits;
Council Directive 98/13/EC of 12 March 1998 on the approximation of the laws of the Member States concerning telecommunications terminal and satellite earth station equipment.
Appendices · and · and

Appendix D: C endix D: C endix D: C endix D: C endix D: Configuration Metho ation Metho ation Metho ation Metho ation Methods dsds dsds
The following is a description of the menus. Network Configuration Menu. Select this menu to configure network parameters such as the switch type, data and voice TEIs, and datea nd voice MSNs. When you finish, select Save Hetwork Configuration to save your work. Call Control Configuration Menu. Select this menu to change how the MTA128ST/NT originates and answers calls. Options include Auto Answer, Rings to Answer, Dialing Method, and Persistent DTR Dialing. Data Protocols Menu. Select this menu to change the rate adaption protocol used by the MTA128ST/NT. Stored Numbers Menu. Select this menu to store up to ten phone numbers with a maximum of 25 characters each. Stored number 0 is the phone number that is dialed if you enable persistent DTR dialing. Port Control Configuration Menu. Select this menu to configure the MTA128ST/NT’s serial port, including how the MTA128ST/NT responds to control signals on the RS232 interface. POTS Port Configuration Menu. Select this menu to configure the MTA128ST/NT’s POTS port which includes the ring type, frequency, and pattern. Help Menu. Select this menu for help on navigating through the MTA128ST/NT menu system. Configuration via AT Commands
You can configure the MTA128ST/NT by using AT commands, just as you would configure an analog modem.
Use this method if you prefer to work with AT commands or if you have a special requirement not addressed by either of the configuration utilities.
Using AT Commands to Configure the MTA128ST/NT 1. Connect a VT100/ANSI-compatible terminal, or a computer that has a communications program that has VT100/ANSI terminal emulation, to the MTA128ST/NT’s serial port. 2. Turn on the MTA128ST/NT. The MTA128ST/NT automatically detects whether an ASCII or ANSI terminal is in use and adjusts accordingly. 3. Start a data communication program and select the COM port where the MTA128ST/NT is connected. 4. Referring to your Before Your Start notes, enter the desired AT commands in the terminal window of the data communications program. 5. When you finish making changes, use the &W command to save your new configuration, and to select it to automatically load when the MTA128ST/NT is turned on. 6. Quit the data communications program. For more information on AT commands, see the MTA128ST and MTA128NT AT Commands documents
Appendices

speed you need in any situation. Allows you to automatically add and drop b-channels according to your preference; you pay only for the bandwith you need. basic access—A term that describes a simple standardized combina- tion of access channels that constitute the access arrangements for most ISDN users. B-channel (bearer channel)—A 64 Kbps ISDN channel used for digital high-speed data or voice transmission. Simultaneous voice and data transmission requires subscription to two B-channels. A voice call can be placed or received while a data call is in process (or vice versa); however, two simultaneous voice or two simulta- neous data calls are not supported. bearer capability (BC)—The level of functionality provided by the ISDN B-channel (e.g., data, 3.1 KHz audio, etc.). bearer services—A set of ISDN functions provided by the B- channel, such as digital telephony, toll-free inbound/outbound calls, 64 Kbps circuit switched data, X.25 packet switched data, and frame relay data. bit—A bit (binary digit) is a basic unit of information used in computing and other digital electronics. It can take a value of either 1 or 0, represented in a computer by a high or low electrical charge. BONDING (Bandwidth on Demand Interoperability Group)—An inverse multiplexing method that combines multiple ISDN channels into a single channel for enhanced throughput. Trademark of the BONDING Consortium. BONDING mode 1—An industry-standard ISDN B channel aggre- gation protocol that was developed by the Bandwidth On Demand Interoperability Group. This mode supports user data rates that are multiples of the bearer rate. It provides the full available bandwidth, but no in-band monitoring. Mode 1 is common to all implementa- tions of BONDING; Modes 0, 2, and 3 are optional. BONDING Consortium—A group that develops specifications for common control and synchronization for management of high-speed data over the public network. BONDING Specification 1.0— The Version 1.0 BONDING specification (August 1992) defines four modes of inverse multi- plexing interoperability. It allows devices from various manufactur- ers to subdivide a wideband signal into 64 Kbps or 56 Kbps channels, and then pass the individual channels over a switched digital network, recombining them into a single high-speed signal at the receiving device. BONDING Specification 1.1— The Version 1.1 BONDING specification (September 1993) incorporates changes to the 1.0 specification resulting from interworking tests among various vendors, and comments from the TIA standardization process. No changes were made to the BONDING algorithm or procedures. bps (bits per second)—The unit of speed at which data bits can be transmitted or received. Bps differs from baud when more than one bit is represented by a single cycle of the carrier. BRI (basic rate interface)—Also called 2B+D. One of two forms of ISDN service. BRI provides two 64 Kbps B-channels for video, voice or data, and one 16 Kbps D-channel for control information. The total BRI data rate is 192 Kbps, with 144 Kbps available to the user. See also ISDN and PRI. buffer—A temporary storage register or random access memory (RAM), used in all aspects of data communications, that prevents data from being lost due to differences in transmission speed. Keyboards, serial ports, muxes and printers are a few examples of devices that contain buffers.
Symbol 2B1Q (2 bits, 1 quarternary)—A line code at layer one for the BRI U interface. Two bits of data (2B) are mapped into one of four line values (1Q, or 1quarternary). This coding scheme allows a single copper pair to carry 160 Kbps of information bidirectionally and simultaneously at a distance of up to three miles.
A ACK (acknowledgement code)—A communications code sent from a receiving modem to a transmitting modem to indicate that it is ready to accept data. It is also used to acknowledge the error-free receipt of transmitted data. Contrast with NAK. address—A numbered location inside a computer. The computer uses addresses to access resources such as video cards, serial ports, memory, etc. analog signal—A waveform that has amplitude, frequency, and phase, which takes on a range of values between its maximum and minimum points. analog transmission—A type of telecommunications that uses an analog signal as a carrier of voice, data, video, etc. An analog signal becomes a carrier when it is modulated by altering its phase, ampli- tude, and/or frequency to correspond with the source signal. Com- pare with digital transmission. API (application program interface)—A software module created to allow dissimilar, or incompatible applications programs to trans- fer information over a communications link. APIs may be simple or complex; they are commonly required to link computer applications with mainframe programs. ASCII (American Standard Code for Information Interchange)— Pronounced ass-key. A binary code for data that is used in communi- cations and in many computers and terminals. The code is used to represent numbers, letters, punctuation, and control characters. The basic ASCII code is a 7-bit character set, which defines 128 possible characters. The extended 8-bit ASCII code defines 255 characters. ASI (application services interface)—A software module that creates the interface between a LAN-connected PC and the network operat- ing system. ASIs packetize computer data for transport over the network. NASI, NCSI, MCSI and NETCI are specific examples. AT commands—A standard set of commands used to control modems. Each AT command string begins with the characters AT, which get the attention of the modem before the actual command is issued. See also command mode.
B background—An activity that takes place in the computer while you are running another application. In other words, the active user interface does not correspond to the background task. bandwidth—The transmission capacity of a computer channel, communications line or bus. It is expressed in cycles per second (hertz), the bandwidth being the difference between the lowest and highest frequencies transmitted. The range of usable frequencies that a transmission medium will pass without unacceptable attenuation or distortion. Bandwidth is a factor in determining the amount of information and the speed at which a medium can transmit data or other information. Bandwidth-on-Demand—Ability to request the amount of data
Glossary

bus—A common channel between hardware devices, either inter- nally between components in a computer, or externally between stations in a communications network. byte—A unit of information consisting of eight binary digits (bits). A byte holds the equivalent of a single or character (such as the letter A).
office. D-channel—A non-ransparent digital ISDN channel that operates at 16K or 64 Kbps, used for call control signalling, along with one or more B- channels. The D (demand) channel signal can control call setup, call teardown, and invocation of Supplementary Services. Is also used for telemetry and for low-speed, low-priority packet-switched data. Contrast with B-channel. default—A preset value or option in software packages or in hard- ware configuration that is used unless you specify otherwise. device driver—Software that controls how a computer communi- cates with a device, such as a printer or mouse. digital data—Information represented by descrete values or condi- tions (contrast analog data). digital PBX—A private branch exchange that operates internally on digital signals. See also exchange. digital signal— A discrete or discontinuous signal (e.g., a sequence of voltage pulses). Digital devices, such as as a series of electrical pulses that have discrete jumps rather than gradual changes. digital transmission—A method of electronic information transmis- sion common among computers and other digital devices. Because a digital signal may be only high or low at any given time, noise and distortion can easily be removed from digital transmissions. digitize—To convert an analog signal to a digital signal. DIP switch—Pronounced dip switch. A set of tiny toggle switches, built into a DIP (dual in-line package), used for setting configurable parameters on a printed circuit board. DN (directory number)—The phone number assigned to an ISDN TA at subscription time. It is a string of up to 24 characters, consist- ing of the valid dialing characters (0-9, *, and #). driver—A software module that interfaces between the operating system and a specific hardware device (e.g., color monitors, printers, hard disks, etc.). Also known as a device driver. DTE (data terminating equipment)—A term used to include any device in a network which generates, stores or displays user infor- mation. DTE is a telecommunications term that usually refers to PCs, terminals, printers, etc. DTMF (dual-tone multifrequency)—A generic push-button concept made popular by AT&T TouchTone. DTMF detection—A capability in some fax/data modems that can differentiate between DTMF or fax calling tones. A typical applica- tion would be a program that routes calls to specific communica- tions applications, depending either on the type of call or on a DTMF tone added to a dialing string.
C Call Bumping—TA feature that reallocates the second B-channel to an analog port when both B-channels are in use. If you are perform- ing a data transfer using both channels and need to make a phone call, one channel is dropped to handle the call and then is reestab- lished after it is completed. With call bumping you don’t miss any calls. call setup time—The time to establish a circuit-switched call between two points. Includes dialing, wait time, and central office– long distance service movement time. carrier signal—An analog signal with known frequency, amplitude and phase characteristics used as a transport facility for useful information. By knowing the original characteristics, a receiver can interpret any changes as modulations, and thereby recover the information. Centrex—A multi-line service, offered by telephone companies, that provides functions and features comparable to those of a PBX for large business users. See also PBX, exchange. channel—A data communications path between two computer devices. It can refer to a physical medium (e.g., UTP or coax), or to a specific carrier frequency. In ISDN, two types of channels are specified: transparent (user can define the service), and nontransparent (service is assigned protocols for specific network functions). ISDN channel names are designated by a single letter, from A through M, sometimes combined with a number (see B- channel and D-channel). CHAP(Challenge Handshake Authentication Protocol)—Security method used to verify the identity of a person or process. CHAP MD5—Chap with MD5 digital signature algorithm imple- mented. circuit-switched network—A technology used by the PSTN that allocates a pair of conductors for the exclusive use of one communi- cation path. Circuit switching allows multiple conversations on one talk path only if end users multiplex signals prior to transmission. circuit switching—The temporary connection of two or more communications channels using a fixed, non-shareable path through the network. Users have full use of the circuit until the connection is terminated. CO (central office)—The lowest, most basic, level of switching in the PSTN (public switched telephone network). A business PABX or any residential telephone connects to the PSTN at a central office. COM port—A serial communications port on a personal computer. Normally, there are two: COM1 and COM2. CPE (customer premise equipment)—The generic term for data communications and/or terminal equipment that resides at the user site and is owned by the user (e.g., not telephone company equip- ment).
E EEPROM (Electrically Eraseable Programmable Read-only Memory)—Upgradable memory chip often used to store firmware. EISA (Enhanced Industry Standard Architecture)—Pronounced eesa. The purpose of the EISA bus is to provide a 32-bit bus for faster throughputs while maintaining backward compatibility with the classic ISA bus architecture. ET (exchange termination)—The carrier’s local exchange switch. Contrast with LT (loop termination). exchange—A unit (public or private) that can consist of one or more central offices established to serve a specified area. An exchange typically has a single rate of charges (tariffs) that has previously
D DCE (data communications equipment)—Any device that serves as the port of entry from the user equipment to a telecommunications facility. A modem is a DCE for the telephone network (PSTN) that is commonly on site at the user’s premises. Packet Switched Networks have another level of DCE that is most often located at a central
Glossary

been approved by a regulatory group. exchange area—A geographical area with a uniform set of charges (tariffs), approved by a regulatory group for telephone services. Calls between any two points within an exchange area are local calls. See digital PBX and PBX.
university, government, and private users around the world. Internet address—A unique 32-bit address for a specific TCP/IP host on a network. Normally printed in dotted decimal format (e.g., 129.128.44.227). I/O address—A location within the I/O address space of your computer used by a device, such as an expansion card, a serial port, or an internal modem. The address is used for communication between software and a device. IP address—A unique 32-bit address for a specific TCP/IP host on a network. Normally printed in dotted decimal format (e.g., 129.128.44.227). IRQ (interrupt request)—The notification a processor receives when another portion of the computer’s hardware requires its attention. IRQs are numbered so that the device issuing the IRQ can be identified, and so that IRQs can be prioritized. ISA (Industry Standards Architecture)—Pronounced ice-a. The classic 8- or 16-bit architecture introduced with IBM’s PC-AT computer. Due to speed constraints, IBM later introduced a restruc- tured Micro Channel Architecture with a 32-bit bus and increased addressing capabilities. ISDN (Integrated Services Digital Network)—International telecom- munications standard for transmitting voice, video and data over a digital communications line. ITU-T (formerly CCITT)—International Telecommunications Union–Telecommunications Sector; the United Nations organization that prepares standards for resolving communications issues and problems.
F fax (facsimile)—Refers to the bit-mapped rendition of a graphics- oriented document (fax) or to the electronic transmission of the image over telephone lines bit-mapped approximation of a graphical document and, therefore, cannot be accurately interpreted according to any character code. firmware—Software that is stored in read-only memory (ROM). Unlike random access memory (RAM), ROM can retain its content without electrical power. Some ROM, known as EEPROM, can be reprogrammed electrically while it is in a device. foreground—The application program currently running on and in control of the PC screen and keyboard. The area of the screen that occupies the active window. Compare with background. frequency—A characteristic of an electrical or electronic signal which describes the periodic recurrence of cycles. Frequency is inversely proportional to the wavelength or pulse width of the signal (e.g., long wavelength signals have low frequencies and short wavelength signals yield high frequencies).
H handshaking—A process that two modems go through at the time of call setup to establish synchronization over the data communica- tions link. It is a synchronization and negotiation process accom- plished by the exchange of predefined, mutually recognized control codes. HDLC (High-Level Data Link Control)—An ISO standard, bit- oriented data communications protocol that provides nearly error- free data transfers. hexadecimal—A base 16 numbering system in which one character represents a four-bit binary value. Hexadecimal notation uses the numbers 0–9 and the letters A–F, usually suffixed by an h (e.g., 4CF h).
L LAPB (Link Access Procedure Balanced)—Based on the X.25 Layer 2 specification. A full-duplex, point-to-point, bit-synchronous protocol commonly used as a data link control protocol to interface X.25 DTEs. LAPB is the link initialization procedure that estab- lishes and maintains communications between the DTE and the DCE. LAPD (Link Access Protocol for the D-Channel)—Based on the ISDN Q.921 specification. A full-duplex point-to-point bit-synchronous link-level protocol for ISDN connec- tions; different from LAPB in its framing sequence. Transmission is in units called frames, and a frame may contain one or more X.25 packets. link optimization—An ISDN feature that permits only user data to open the communications link and keeps administrative packets from opening the link. A cost saving feature that ensures that remote connections are not unnecessarily utilized. local loop—A transmission path, typically twisted-pair wire, be- tween an individual subscriber and the nearest public telecommuni- cations network switching center. Also called the subscriber loop. LT (loop termination)—A device, similar to an NT1, that terminates the local loop at the carrier’s central switching office. The LT provides the interface to the ISDN U reference point. Contrast ET (exchange termination).
I IDN (Integrated Digital Network)—The culmination of transmission and switching functions using digital technology in a circuit- switched telecommunications network. IEC (Inter-Exchange Carrier)—A telephone company that is al- lowed to provide long distance telephone service between LATAs, but not within any one LATA. Also called IXC. IETF(Internet Engineering Task Force)— A self-organized group of people who make technical and other contributions to the engineering and evolution of the Internet and its technologies. It is the principal body engaged in the development of new Internet standard specifications. I-mux (inverse multiplexer)—A device that will dial up and com- bine several lower speed circuits into a virtual broadband circuit. It takes any multiple up to an aggregate bandwidth, giving users bandwidth on demand for videoconferencing, LAN-to-LAN connec- tions, etc. In ISDN devices, inverse multiplexing is performed by the BONDING protocol. in-band signaling—A technique in which connection control information is sent over the same channel as assigned to the sub- scriber for end-to-end communication. Two common examples are DTMF line signaling and MF trunk signaling. Internet—A computer network consisting of many millions of
M MD5(MD5 Message-Digest Algorithm)—Takes a message if arbitrary length as input and produces it as output as a 128-bit fingerprint or message digest of the input. The MD5 algorithm is used for digital signature applications where a large file must be
Glossary

compressed in a secure manner before being encrypted with a private (secret) key under public-key cryptisystem. MLPPP (Multilink Point-to-Point Protocol, also the PPP Multilink Protocol or MP)—is an Internet standards track protocol for a methyod of splittingm recombining, and sequencing datagrams across multiple logical data links, giving you additional bandwith- on-demand. Originally, MLPPP was used to combine two ISDN BRI channels into a single high-speed data path, but now is also used anywhere multiple PPP links connect two systems, including async links. This is done with new PPP options and protocols. Also knows as MPPP and PPP Multilink, MLPPP is an effective means of bonding channels for providing bandwith-on-demand. modem—A communications device that enables a computer to transmit information over a telephone line. It converts the computer’s digital signals into analog signals to send over a tele- phone line and converts them back to digital signals at the receiving end. Modems can be internal and fit into an expansion slot, or external and connect to a serial port. MP+(MultiLink Protocol Plus)—An extension to the PPP Multilink Protocol (MP) convered in IETF RFC 1717. MP+ is a new control protocol for managing multiple data links that are bundled by MP. Also called the Multichannel Protocol Plus or MPP. MS-CHAP—Microsoft version of CHAP. multilink—In point-to-point protocol, literally many links. A procedure used to route data packets over many links for increased bandwidth (e.g., two B-channels on a single BRI for 128 Kbps). mux (multiplexer)—A device that merges several signals into one composite signal for transmission over a single medium or channel. A demultiplexer, built into most muxes, reverses the process at the receiving end.
OSI Layer 1 level. Similar in function to a DSU/CSU device. NT2 (Network TerminationType 2)—A device at the customer premise (user) side responsible for the ISDN network connection and for functions such as multiplexing and switching (may be an intelligent device). NTE (network terminating equipment)—A set of ISDN functions residing at the boundary of the IDN and the subscriber. NUI (network user identification)—A unique alphanumeric number provided to dial-up users to identify them to packet-switched net- works world-wide. The number is used for network access and billing.
O off-hook—The condition of a device that has accessed a phone line (with or without using the line). In modem use, this is equivalent to a telephone handset being picked up. Dialing and transmission are allowed, but incoming calls are not answered. on-demand dialing—A cost-saving feature of ISDN that sets up, transfers, and then closes a call only when the ISDN device detects a data packet addressed to the remote network, but will not perform setup/transfers of just administrative (non-user data) packets. out-of-band signaling—A system that uses a separate communica- tions channel or frequency outside the voice band for signaling. Modern systems use a separate channel, either TDM or virtual. SS7 uses messages for signaling that are carried on signaling links distinct from voice channels. ISDN uses messages for signaling that are carried on the D-channel distinct from the voice carried on the B-channels. Frame Relay and ATM use messages that are carried on a separate virtual connection reserved for signaling. on-hook—The condition of a device which has not accessed a phone line. In modem use, this is equivalent to a telephone handset that has not been picked up. In other words, it can receive an incom- ing call.
N nailed connection—A permanent or dedicated circuit of a previ- ously switched circuit or circuits. nailed-up circuit—A semi-permanent circuit established through a circuit-switching facility for point-to-point connectivity. NAK (negative acknowledgment)—A communications code used to indicate that a message was not properly received, or that a terminal does not wish to transmit. Contrast with ACK. network—A group of computers connected by cables or other means and using software that enables them to share equipment, such as printers and disk drives to exchange information. NI-1 (National ISDN-1)—A physical standard to make all compliant ISDN lines appear the same. With ISDN-1 installed, additional costs are not incurred when changing from prestandard ISDN to standard ISDN. Most RBOCs now are moving to ISDN-1. NI-2 (National ISDN-2)—A physical standard subsequent to NI1. When tested and deployed, NI-2 will provide additional features and enhanced plug and play capabilities. node—Any point within a network that has been assigned an address. NT (network termination)—Devices that form the boundary be- tween customer premise equipment and telephone company equip- ment. Two types of NTs are used: NT1 and NT2. NT1 (Network TerminationType 1)—An interface device used in the BRI portion of ISDN to connect four-wire (S/T) ISDN devices to the two-wire (2BIQ U) IDN. It provides basic rate access in a 2B+D format with two 64 bps channels for voice, data, and video commu- nications. It also provides one 16 Kbps channel for packet-mode signalling, low-speed data and telecommunications services at the
P packet data—Packet-mode calls. packet mode—The switching of chunks of information for different users using statistical multiplexing to send them over the same transmission facility. ISDN packet mode capabilities are based on the ITU-TSS Recommendation X.25 procedures. PAP(Password Authentication Protocol): (RFC1334) parity bit—An extra bit attached to each byte of sync—hronous data used to detect errors in transmission. PBX (private branch exchange)—A telephone exchange located on the customer’s premises. The PBX provides a circuit switching facility for tlephone extension lines within the building, and access to the public telephone network. See also exchange. P-channel (PCHAN)—The ISDN physical channel identification; contrast logical channel or virtual channel. PDN (public data network)—A packet-switched network that is available to the public for individual (subscriber) use. Typically, controlled by a government or a national monopoly. port—A location for input or output data exchange. Computers, muxes, etc. have ports for various purposes. PPP (Point to Point Protocol)—A protocol that lets a computer user access a TCP/IP address using an ISDN terminal adapter or a high- speed modem over a standard telephone line. PRI (Primary Rate Interface)—One of two forms of ISDN service. PRI provides 23 64 Kbps B-channels for video, voice or data, and one 64 Kbps D-channel for control
Glossary

services. Also called the S-interface. (Contrast R-reference point.) SAP (service access point)—A point at which the services of an OSI layer are made available to the next higher layer. See also SAPI. SAPI (service access point identifier)—A logical point at which data link layer services are provided by a data link layer entity to a layer 3 entity. See also SAP. serial port—The connector on a PC used to attach serial devices (those that need to receive data one bit after another), such as a mouse, a printer or a modem. This consists of a 9- or 25-pin connec- tor that sends data in sequence (bit by bit). Serial ports are referred to as COMx ports, where x is 1 to 4 (e.g., COM1 through COM4). A serial port contains a conversion chip called a UART that translates between internal parallel and external serial formats. service—The requirements offered by an RPOA to its customers to satisfy specific telecommunications needs. signaling—The process of establishing, maintaining, accounting for, and terminating a connection between two endpoints (e.g., the user premises and the telco CO). Central office signals to the user pre- mises can include ringing, dial tone, speech signals, etc. Signals from the user’s telephone can include off-hook, dialing, speech to far-end party, and on-hook signals. In-band signaling techniques include pulse and tone dialing. With common channel signaling, information is carried out-of-band. In ISDN, signaling includes the call establishment, call progress monitoring, call termination and enhanced telephone features provided typically by the D-Channel. See also SS7, out-of-band signaling, and in-band signaling. SPID (service profile identifier)—In North America, the ISDN network parameter for logical terminal identification and tracking, provided by the ISDN provider. The voice SPID and data SPID identify a particular set of service or feature parameters. They are assigned by the ISDN service provider, in the form of a string of up to 20 characters, at subscription time. The SPID actually points to a specific location in central office memory where the relevant informartion is stored. SS7 (Signaling System 7)—An ITU-T and ANSI standard for digital out-of-band signalling between central offices that provides much of the network switching intelligence to support many ISDN functions stop bit—One of the variables used for timing in asynchronous data transmission. Depending on the devices, each character may be trailed by 1, 1.5, or 2 stop bits. subscriber loop—The pair of wires that connect the end user to the telephone network. These wires provide ISDN service, but also require an NT1 at the enduser location as well as the LT at the network end. See also local loop. supplementary services (SS)—ISDN functions beyond the basic requirements; includes videoconferencing, fast dialing, call waiting, call forwarding, calling line ID. SVC (switched virtual circuit)—A type of data transmission where the connection is maintained only until the call is cleared. SVD (simultaneous voice and data)—A technology for letting a user send data via a modem, and use a handset to talk to another user at the same time over the same connection. The alternative, making a second call, can be expensive or even impossible. The uses for SVD are telecommuting, videoconferencing, distant learning, tech sup- port, etc. switched 56—A circuit-switched (full duplex digital synchronous data transmission) service that lets you dial a number and transmit
information. Usually used to connect high-cpacity CPE, such as PBXs, to the network. Also called 23B+D in the U.S. and 30B+D in Europe.) See also ISDN and BRI. primitive—An abstract representation of interaction accross the access points indicating that information is being passed between the service user and the service provider. The OSI Reference Model defines four types of primitives: Request, Indication, Response and Confirm. PSTN (public switched telephone network)—The group of circuit- switching voice carriers, which are commonly used as analog data communications services. A worldwide public voice telephone network that is used as a telecommunications medium for the transmission of voice, data and other information. pulse dialing—One of two methods of dialing a telephone, usually associated with rotary-dial phones. Compare with tone dialing. PVC (permanent virtual circuit)—A connection between two endpoints dedicated to a single user. In ISDN, PVCs are established by network administration and are held for as long as the user subscribes to the service.
Q Q.921—The ITU-T recommendation for user-network interface layer 2 specifications for D-channel signaling. Similar to LAPD. See also ISDN. Q.931—The ITU-T recommendation for user-network interface layer 3 specifications for D-channel signalling. See also ISDN.
R R reference point—Establishes the boundary between non-ISDN compatible equipment (TE-2) and the IDN network. TAs are used to convert the communication protocol used by the non-ISDN termnials to the desired BRI or PRI protocol. Non-ISDN (TE2) terminal equipment connects to IDN at the R-Reference point with a TA. (This interface may follow the RS232 or V.35 specification.) Also called the R interface. (Contrast S reference point.) RAM (random access memory)—A computer’s primary workspace. All data must be stored in RAM (even for a short while), before software can use the processor to manipulate the data. Before a PC can do anything useful it must move programs from disk to RAM. When you turn it off, all information in RAM is lost. reference point—A connection point between ISDN equipment classes (rather than the specific protocol of the interconnection). Can include R, S, T, and U reference points. RFC(Request for Comments)—Name for the IETF document that provides internet standards. RJ-11—An industry standard interface used for connecting a telephone to a modular wall outlet; comes in 4-and 6-wire packages. RJ-45—An 8-wire modular connector for voice and data circuits. RPOA (recognized private operating agency)—A corporation, private or government-controlled, that provides telecommunications services. RPOAs, such as AT&T, participate as non-voting members in the ITU-T. RS-232—An EIA/TIA standard for a serial interface between computers and peripheral devices (modem, mouse, etc.). It uses a 25-pin DB-25, or a 9-pin DB-9 connector. The RS-232 standard defines the purposes, electrical characteristics and timing of the signals for each of the 25 lines. Similar to the ITU-T V.24 standard.
S S reference point—Provides the connection between NT2 equip- ment and the TA or TE-1. Can provide both primary and basic rate
Glossary

data to it at 56 Kbps. It is a relatively low cost service, widely used in North America for telecommuting, videoconferencing and high speed data transfers. Many phone companies are phasing out switched 56 in favor of ISDN service. switched line—In communications, a physical channel established by dynamically connecting one or more discreet segments. This connection lasts for the duration of the call after which each segment may be used as part of a different channel. Contrast with leased line. switched network—A network in which a temporary connection is established from one point via one or more segments. synchronous transmission—The transmission of data which involves sending a group of characters in a packet. This is a com- mon method of transmission between computers on a network or between modems. One or more synchronous characters are transmit- ted to confirm clocking before each packet of data is transmitted. Compare to Asynchronous Transmission.
associated with Touch-Tone® (push button) phones. Compare with pulse dialing. TSR (terminate and stay resident)—A software program that re- mains active and in memory after its user interface is closed. Similar to a daemon in UNIX environments. twisted pair wiring—A type of cabling with one or more pairs of insulated wires wrapped around each other. An inexpensive wiring method used for LAN and telephone applications, also called UTP wiring.
U U reference point—A twisted-pair subscriber loop that connects the LT to the NT1. Normally a 2-wire BRI or PRI line is used, but a 4- wire BRI can also be used. In the US, the U Reference Point marks the separation point between CPE and the network. UART (universal asynchronous receiver/transmitter)—An inte- grated circuit that transmits and receives data on the serial port. It converts parallel bytes into serial bytes for transmission, and vice versa, and generates and strips the start and stop bits appended to each character. UTP (unshielded twisted pair) —Telephone-type wiring.
T T—Provides the connection between the NT1 and NT2. Can be internal to or external from the PABX. Provides the connection between the NT1 equipment and the TA or TE-1. Can provide both Primary Rate and Basic Rate services. TA—See terminal adapter. TCP/IP (Transmission Control Protocol / Internet Protocol)—A multi-layer set of protocols developed by the US Department of Defense to link dissimilar computers across dissimilar and unreliable LANs. TEI (terminal endpoint identifier)—A unique number that is as- signed to an ISDN terminal adapter at subscription time. The TEI is used by the central office to identify the various TAs connected to the ISDN network. The TEI number can be fixed (in the range 0f 0- 63, or dynamic, automatically assigned at the CO each time the TA is connected to the ISDN interface and powered up. TE1 (Terminal Equipment Type 1)—A terminal device with a standard ISDN interface (an ISDN-compatible terminal). TE2 (Terminal Equipment Type 2)—A terminal device with a non- ISDN interface, such as RS232, RS449, V.35 or X.21. Can be a telephone, data terminal, or voice/data worrkstation, etc. telecommunication service—A function, such as bearer service and teleservice, offered by an RPOA to its customer in order to satisfy a specific telecommunications requirement. See also ISDN, RPOA, and bearer service. telematics—User-oriented ISDN information transfer services (e.g., teletex, videotex, facsimile). Teleservices—A telecommunications service that provides the complete capability for communication between subscribers accord- ing to protocols agreed to by RPOAs. A set of ISDN features using communications links, including E-Mail and fax services. Teletext—A telecommunications service that provides a one-way information retrieval service that uses unused portions of a TV channel bandwidth. A fixed number of text pages are repetitively broadcast for decoding by a decoder at the TV set that can select and display pages. See also ISDN. terminal—The screen and keyboard device used in a mainframe environment for interactive data entry. Terminals have no box, which is to say they have no file storage or processing capabilities. terminal adapter (TA)—An ISDN DTE device for connecting a non-ISDN terminal device to the ISDN network. Similar to a protocol converter or an interface converter, a TA connects a non- ISDN device between the R and S interfaces. tone dialing—One of two methods of dialing a telephone, usually
V V.110—One of the terminal rate adaptation protocols for the ISDN B-channel. V.110 is more hardware-intensive than the V.120 B- channel standard. V.120—One of the terminal rate adaptation protocols for the ISDN B-channel. V.120 is more software-intensive than the V.110 B- channel standard. Videotex—A two-way information-retrieval service that can be accessed by terminals and by a TV set (with installed decoder). Allows interactive retrieval of information pages from a central resource. See also ISDN. virtual circuit—A logical connection. Used in packet switching wherin a logical connection is established between two devices at the start of transmission. All information packets follow the same route and arrive in sequence (but do not necessarily carry a complete address).
X X.25—ITU-T’s definition of a three-level packet-switching protocol to be used between packet-mode DTEs and network DCEs. X.25 corresponds with layer 3 of the 7-layer OSI model. X.75—An ITU-T standard for linking X.25 packet-switched net- works. X.75 defines the connection between public networks, i.e., for a gateway between X.25 networks.
Glossary




Pages referenced in this manual — manufacturer, support and downloads.
What the fault codes shown on the display mean and how to clear them.
| Code | Meaning | Fix | |
|---|---|---|---|
| ER5 | Troublesho | p.34 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.