PC Card Modem
MT5634ZLX MT5634ZLXI MT5634ZLX/FE
User Guide


MT5634ZLX, MT5634ZLXI, MT5634ZLX/FE P/N S000266A Revision A Copyright © 1999-2002 by Multi-Tech Systems, Inc. All rights reserved. This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech Systems, Inc. Multi-Tech Systems, Inc. makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.
Revision Date Description A 08/07/02 MT5634ZLX MultiMobile Family User Guide initial release.
Patents 4,453,450; 4,603,320; 4,686,506; 4,972,470
Trademarks MultiMobile and the Multi-Tech logo are trademarks of Multi-Tech Systems, Inc. Adobe and Acrobat are trademarks of Adobe Systems Incorporated. Microsoft, Windows is either a registered trademark of Microsoft Corporation in the United States and/or other countries. All other brands and product names mentioned in this publication are registered trademarks of their respective companies.
World Headquarters Multi-Tech Systems, Inc. 2205 Woodale Drive Mounds View, MN 55112 U.S.A Telephone (763) 785-3500 or (800) 328-9717 Fax (763) 785-9874 Internet http://www.multitech.com
Technical Support Country By Email By Phone France [email protected] +(33) 1-64 61 09 81 India support@multitechindia.com +91 (124) 6340778 U.K. support@multitech.co.uk +(44) 118 959 7774 U.S. and Canada support@multitech.com (800) 972 -2439 Rest of the World support@multitech.com +(763) 717-5863 Note the status of the modem before contacting Technical Support. The status can include information about LED indicators, screen messages, diagnostics test results, problems with an application, etc.
Recording Your Modem Information Record the following information about your Multi-Tech modem before calling Technical Support. Modem Model Number: Modem Serial Number: These numbers are printed on the bottom of the modem.



Chapter 1 – Introduction
Chapter 1 – Introduction Chapter 1 – Introduction Chapter 1 – Introduction Chapter 1 – Introduction
The MultiMobile PC Card modems offer high-speed performance and reliability for mobile users with laptops. They provide the flexibility needed for local and remote connections to the Internet. These Type II PCMCIA credit card size modems comply with the PCMCIA 2.1 and JEIDA 4.1 standards and support the fastest downloading speeds available over standard phone lines.
They are Bell, ITU-T and AT command compatible, allowing them to be used worldwide (except for the ZLX which is limited to the United States and Canada) with today’s popular communication software programs. You can send and receive faxes with any Group 3 compatible fax device.
The MultiMobile PC Cards are fax/modem communications devices that perform the following communications tasks:

Chapter 1 – Introduction

Chapter 1 – Introduction
Your modem has several components. Please make sure you have all parts before trying to operate your modem.



Chapter 2 – Installation
Chapter 2 – Installation Chapter 2 – Installation Chapter 2 – Installation Chapter 2 – Installation
Installing the MT5634ZLX Card Installing the MT5634ZLX Card Installing the MT5634ZLX Card Installing the MT5634ZLX Card

Installing the MT5634ZLXI Card Installing the MT5634ZLXI Card Installing the MT5634ZLXI Card Installing the MT5634ZLXI Card
OH (Off-Hook) light on means the MT5634ZLXI is dialing, is online, or answering a call.
CD (Carrier Detect) light on means a valid carrier signal from another modem is detected.
RD (Receive Data) light flashes when data is being received.
TD (Transmit Data) light flashes when data is being transmitted.

MT5634ZLX Connections · MT5634ZLXI Connections

Chapter 2 – Installation
Installing the MT5634ZLX/FE Card Installing the MT5634ZLX/FE Card Installing the MT5634ZLX/FE Card Installing the MT5634ZLX/FE Card
OH (Off-Hook) light on means the MT5634ZLXI is dialing, is online, or answering a call.
CD (Carrier Detect) light on means a valid carrier signal from another modem is detected.
RD (Receive Data) light flashes when data is being received.
TD (Transmit Data) light flashes when data is being transmitted.
ACT light on means there’s activity on the line.
10/100 light on means 100m; 10/100 light off means 10m.
Link light on means the line is active.

MT5634ZLX/FE Connections

Chapter 2 – Installation
Installing the Modem Driver Installing the Modem Driver Installing the Modem Driver Installing the Modem Driver
You must install the modem’s driver onto the hard drive of your laptop PC. If you are using Windows 95/98/Me/2000/XP, the driver is installed with Windows’ Plug and Play feature. For Windows NT, which does not support Plug and Play, see the Modem Driver Installation for Windows NT below.

Chapter 2 – Installation
Installing Data Communication Software Installing Data Communication Software Installing Data Communication Software Installing Data Communication Software
Data communications software is designed to enable your modem to send and receive data. Multi-Tech has included a communications software program, Phone Tools, with your modem. To install Phone Tools:
The PC Card is a hot-swappable card. However, when MT5634ZLX/FE is connected to a LAN and transferring data, it is recommended that you use the following steps to eject the PC Card if you choose to do so during this process. Removing the PC Card during this process without using these steps could cause Windows to lock up.
Configure the Modem for Your Country Configure the Modem for Your Country Configure the Modem for Your Country Configure the Modem for Your Country
Different countries have different requirements for how modems must function. Therefore, before you use your modem, you must configure it to match the defaults of the country in which you are using it. You can use one of two configuration methods:

Chapter 2 – Installation
Before you can connect to the Internet, you must set up a remote-node client program, known as Dial-Up Networking in Windows. Dial-Up Networking establishes your connection to your ISP’s (Internet Service Provider) server, which is the shared computer that manages calls from clients (your computer and other clients’ computers) to the Internet. Most, if not all, Windows browsers start Dial-Up Networking automatically when you open them after you have setup your PC for Dial-Up Networking.
Many ISPs provide a program that will install and configure Dial-Up Networking automatically for you. If this program was not provided, contact your ISP for instructions. You can also find Dial-Up Networking information in your Windows operating system online help or printed documentation.

Chapter 3 – Remote Configuration
Chapter 3 – Remote Configuration Chapter 3 – Remote Configuration Chapter 3 – Remote Configuration Chapter 3 – Remote Configuration
Remote configuration is a network management tool that allows you to configure modems anywhere in your network from one location. With password-protected remote configuration, you can issue AT commands to a remote MultiMobile Modem for maintenance or troubleshooting as if you were on-site.
The following steps are valid regardless of whether the connection is established by the local or the remote Multi-Tech modem.
Multi-Tech modems are shipped with a default setup password (MTSMODEM). Because anyone who has the User Guide knows the default setup password, you should change the password and possibly also the remote configuration escape character.
Changing the Setup Password 1. Open a data communications program such as HyperTerminal.

Chapter 3 – Remote Configuration
To further improve security, you can change a remote modem’s remote configuration escape character. The remote configuration escape character is stored in register S9. The factory default is 37, which is the ASCII code for the percent character (%). Setting S9 to 0 (zero) disables remote configuration entirely.

Chapter 4 – AT Commands, S-Registers, and Chapter 4 – AT Commands, S-Registers, and Chapter 4 – AT Commands, S-Registers, and Chapter 4 – AT Commands, S-Registers, and
Typically, your fax and data communications software controls the modem for you. For complete control over your modem, you may also want to use AT commands. Each AT command must be preceded by the characters AT to get the ATtention of the modem. You need to be careful when using these commands because they can cause your software to lose its ability to control the modem. If an AT command you’ve entered has caused a problem, turn the computer off and then back on to reset the modem to factory default settings. You may also reset the factory defaults by typing AT&F&WZ.
The format for entering an AT command is ATXn, where X is the command and n is the value for the command, sometimes called the command parameter. The value is always a number. If the value is zero, you can omit it from the command; (e.g. AT&W is equivalent to AT&W0). Most commands have a default value, which is the value that is set at the factory. The default values are included in the AT Commands section which follows. You must press Enter to send the command to the modem.
To send AT commands to the modem you must use a communications program, such as HyperTerminal, which is included in Windows 95, 98, NT and 2000. You can issue commands to the modem directly by typing them in the terminal window of the communications program or indirectly by configuring the communications program to send the command automatically. If you are using Windows Dial-Up Networking, AT commands can be included in the connection properties (described later in this chapter).
You can issue several commands in one line; this is called a command string. A command string begins with AT and ends when you press Enter. Spaces separating the commands are optional; they are ignored by the command interpreter. The most familiar command string is the initialization string (used to configure the modem when it is turned off, reset, or when your communications software initiates a call to another modem).
To use an AT command, you must first:
For example, type:
ATH0<Enter> to hang up the modem connection, or
AT&K3<Enter> to enable bi-directional CTS/RTS hardware flow control.
Most of the AT commands can be entered in “strings” (i.e., on the same command line) without spaces between the individual commands.
Any time the modem receives a command, it sends a response known as a Result Code. The most common result codes are OK, ERROR, and CONNECT.
Fortunately, communication programs make daily operation of modems effortless by hiding the commands from the user. Most users, therefore need to use AT commands only when reconfiguring the modem, e.g., to turn autoanswer on or off.

The commands labeled as default are factory default settings.
+++AT Escape Sequence puts the modem in command mode (and optionally issues a command) while remaining online. Type +++AT and up to ten command characters, then press ENTER. Used mostly to issue the hang-up command: +++ATH
%%%AT Remote Configuration Escape Sequence initiates remote configuration mode while online with a remote modem. The remote configuration escape character (%) is defined in register S13.
A/ Re-execute the last command string. <any key> Terminate the current connection attempt when entered in handshaking state.
$ Calling Card “Bong” Detection.
A Go off-hook and attempt to establish a connection without waiting for a ring.
Bn Line modulation options.
B0 Select ITU-T V.22 mode for 1200 bps connection and V.21 mode for 300 bps.
B1 (default) Select Bell 212A for 1200 bps connection; Bell 103 for 300 bps.
B2 Select V.23 1200 bps for receiving, 75 bps for transmitting in originate mode; 75 bps for receiving and 1200 bps for transmitting in answer mode.
B3 Select V.23 75 bps for receiving, 1200 bps for transmitting in originate mode; 1200 bps for receiving and 75 bps for transmitting in answer mode.
Dn Dial command, beginning the dialing sequence. The string “n” (telephone number and modifiers) listed as follows is entered after the “D” command.
P Pulse dial. Only digits 0 to 9 can be dialed.
R Reverse dial. Originate call in answer mode (go on-line in answer mode).
Sn Dial the phone number stored in NVRAM at location n (n=0, 1, 2, 3).
T DTMF tone dial. Any digit 0 to 9, *, #, A, B, C… maybe dialed as a tone.
W Wait for second dial tone. The modem waits for the second dial tone before processing the dial string.
, Pause. Causes the modem to pause for a time before processing the dial string (value set by S8 register).
! Flash hook (for call transfer). Causes the modem to go on-hook for 0.5 second then return off-hook.
@ Wait for 5 seconds of silence after dialing a number.

; Return to command state after dialing a number without disconnecting the call.
En AT command echo options.
E0 Echo disabled.
E1 (default) Echo enabled.
Hn Switch-hook control .
H0 Modem goes on-hook.
H1 Modem goes off-hook.
Ln Speaker Volume Control Level (0-3); L3 being the highest.
Mn Speaker control.
M0 Speaker always off.
M1 (default) Speaker on until carrier present.
M2 Speaker always on.
M3 Speaker off during dialing and on until carrier present.
Nn Select negotiate handshake.
N0 When originating or answering, handshake only at the communication rate specified by the S37 register and “ATBn” and no fallback.
N1 (default) When originating or answering, start handshaking only at the comm standard specified by S37 register and “ATBn”. During handshake, fallback to a lower speed may occur except in “AT\N1” mode.
On Go on-line.
O0 Return modem to a previously established state.
O1 Begin an equalizer retrain sequence, then return to on-line state.
O3 to O14 Force modem to a new rate that is user defined. New rates are defined in S62 register.
P Enable pulse dialing.
Qn Result code display options.
Q0 (default) Result code enabled.
Q1 Result code disabled.
T Enable tone dialing.
Vn Result code form.
V0 Display result code in numeric form (see also the result code options table).
V1 (default) Display result code in verbose form.
Wn Select extended result codes.
W0 (default) CONNECT result code reports DTE speed. (See also the “Result Code Options Table”)

W1 CONNECT result code reports DTE speed; enable the CARRIER, COMPRESSION, and PROTOCOL extended result code.
W2 CONNECT result code reports DCE speed.
Xn Select result codes/call progress options.
X0 Display CONNECT or “1” for all speeds.
X1 Display connect message according to “ATW” and “AT\V”, blind dial, ignore busy tone.
X2 Display connect message according to “ATW” and “AT\V”, wait for dial tone, ignore busy tone.
X3 Display connect message according to “ATW” and “AT\V”, blind dial, check busy tone after dialing.
X4 (default) Display connect message according to “ATW” and “AT\V”, wait for dial tone, check busy tone after dialing.
Zn Recall stored profile.
Z0 Reset and recall user profile 0.
Z1 Reset and recall user profile 1.
&Cn Data carrier detect option.
&C0 State of carrier from remote modem is ignored. RLSD (Receive Line Signal Detect) circuit is always on.
&C1 (default) State of carrier from remote modem is tracked. RLSD circuit reflects the state of carrier.
&Dn Data Terminal Ready (DTR) option
&D0 DTR ignored.
&D1 Go to command mode on on-to-off DTR transition.
&D2 (default) Hang up and go to command mode on on-to-off DTR transition. Auto- answer is disabled if DTR is low.
&D3 Hang up and reset from user profile 0 on on-to-off DTR transition.
&F Recall factory default setting as active configuration.
&Gn Guard tone option.
&G0 (default) No guard tone.
&G1 550 Hz guard tone.
&G2 1800 Hz guard tone.
&Jn Dummy command for AutoSync compatibility.
&Kn Set flow control.
&K0 Disable flow control.
&K3 (default) Enable bi-directional hardware flow control (CTS/RTS).
&K4 Enable bi-directional software flow control (XON/XOFF).
&Pn Dial Pulse make/break ratio.

&P0 (default) Make=40%, Break=60% for use in North America.
&P1 Make=33%, Break=67% for International use.
&Rn CTS/RTS option (for non-CTS flow control mode and synchronous mode only).
&R0 (default) CTS follows RTS.
&R1 CTS always true.
&Sn Data Set Ready (DSR) option.
&S0 (default) DSR always on.
&S1 DSR on during handshake and on-line, off in test mode or idle mode.
&Tn Self-test commands.
&T0 (then ^ATO) Terminate test.
&T1 Local analog loopback test.
&T3 Local activated remote digital loopback (RDL) test.
&Vn View active configuration and stored profile.
&V0 View active file, stored profile #0 and stored phone numbers.
&Wn Store active profile.
&W0 Save active configuration as user profile #0.
&W1 Save active configuration as user profile #1.
&Yn Select stored profile on power-up.
&Y0 Recall user profile 0 on power-up.
&Zn=x Store telephone number n=0 to 3.
x= See also the dial modifier in ”ATDn” command. The maximum number of digits per string is 36.
%A Adaptive Answer Result Code Enable.
%Cn Data compression option.
%C0 No compression.
%C1 (default) MNP 5 compression.
\Gn Set modem port flow control.
\G0 (default) Disable port flow control.
\G1 Set port flow control to XON/XOFF.
\Jn Constant DTE speed option.
\J0 (default) DCE and DTE rates are independent.
\J1 DTE rate adjusts to DCE connection rate after on-line.

\K=n Set break control. In on-line data state with V.42 protocol or normal mode, then break signal to DTE through RS-232. n=0 or 2 or 4 Enter on-line command state but do not send break to the remote modem. n=1 Empty the data buffers; send break to remote modem immediately. n=3 Send break to the remote modem immediately. n=5 Send break to the remote modem in sequence with data in on-line data state with direct mode, then receive break signal at serial port. n=0 or 2 or 4 Immediately send break and enter on-line command state. n=1 or 3 or 5 Immediately send break through. In on-line command state with V.42 protocol or normal mode, the DTE issues a transmit break command. n=0 or 1 Empty the data buffers; send the break to remote modem. n=2 or 3 Send break to the remote modem immediately. n=4 or 5 Send break to the remote modem in sequence with data. In on-line data state with normal mode, receive break signal from remote at modem port, send to serial port. n=0 or 1 Empty the data buffers; send the break to the local DTE. n=2 or 3 Send break to local DTE immediately. n=4 or 5 Send break to the local DTE in sequence with data.
\Nn Modem protocol options.
\N0 Normal mode. No protocol, but flow control is allowed.
\N1 Direct mode. No protocol and no flow control are allowed.
\N2 MNP reliable mode.
\N3 (default) LAPM, MNP or normal mode.
\N4 LAPM or MNP mode.
\Qn DTE flow control options.
\Q0 Disable flow control .
\Q1 XON/XOFF software flow control.
\Q2 CTS flow control to DTE.
\Q3 RTS/CTS hardware flow control.
\Tn Set inactive timer.
n=0 (default) Disable inactive timer.
n=1 - 90 Enable inactive timer. Length in minutes.
\Vn Protocol result codes.
\V0 (default) Disable protocol result code (e.g. CONNECT 9600).
\V1 Enable protocol result code (e.g. CONNECT 9600/LAP-M).
\Xn XON/XOFF pass-through options.
\X0 (default) Process XON/XOFF per AT\Gn and AT\Qn option, if XON/XOFF flow control enabled, do not pass XON/XOFF to remote modem or local DTE.
\X1 Process XON/XOFF per AT\Gn and AT\Qn option, always pass XON/XOFF to the remote modem or local DTE.

Certain modem parameters are stored in memory locations called S-Registers. Use the S command to read or alter the contents of S-Registers.
S0 0–255 0 Sets number of the rings required before the modem automatically answers a call. Set “S0=0” to disable auto-answer mode. S1 0–255 0 Counts the incoming rings and stores the value to this register. The value of this register is incremented with each ring. If no rings occur over an 8 seconds interval, this register is cleared. User can read but should not change this value. S2 0–255 043 Holds the decimal value of the ASCII character used as the escape character. The default value (043) corresponds to an ASCII character “+” (plus). A value of 128 to 255 disables the escape process; i.e., no escape character will be recognized 043. S3 0–127 013 Holds the decimal value of the Carriage Return character used as the command line and result code terminator (asynchronous operation only). S4 0–127 010 Holds the decimal value of the character recognized as a line feed after the carriage return control character, if verbose result codes are enabled. S5 0–127 008 Holds the decimal value of the character recognized as a backspace (asynchronous operation only). The modem will not recognize the backspace character if this register is set to a value greater than 32. S6 0–255 002 Sets the length of time, in seconds, that the modem must wait (minimum 2 seconds even if the value is less than 2) after going off-hook before dialing the first digit of the telephone number. S7 1–255 050 Sets the time, in seconds, that the modem must wait before hanging up because a carrier is not detected. S8 0–255 002 Sets the time, in seconds, that the modem must pause when the “,” dial modifier is encountered in the dial string. S10 1–255 020 Sets the length of time, in tenths of a second, that the modem waits before hanging up after a loss of carrier. S11 50–255 095 Sets the DTMF duration and inter digit delay in milliseconds, in DTMF touch-tone dialing. S12 0–255 050 Defines the maximum period, in 2-hundredths of a second, allowed between consecutive asynchronous escape character “+” (plus) for the escape sequence to be considered valid. S16 0–18 0 Selects DTE speed during data transfer.
0 Last auto-baud speed 1 300 bps 2 600 bps 3 1200 bps 4 2400 bps 5 4800 bps 6 9600 bps 7 7200 bps 8 12000 bps 9 14400 bps 10 16800 bps 11 19200 bps 12 21600 bps 13 24000 bps 14 26400 bps 15 28800 bps 16 38400 bps 17 57600 bps
Register Range Factory · Default Description

18 115200 bps S18 0–255 000 Sets the length of time, in seconds, that the modem conducts a test (commanded by “AT&Tn”) before returning to command mode. If this register value is zero, the test automatically terminates, the test progress must be ended by issuing “AT&T0” or “ATH” commands. S25 0–255 005 Sets the length of time, in hundredths of a second, which the modem ignores before hanging up. S30 0–90 000 Controls the inactivity timer, which sets the length of time, in minutes, that the modem counts when there is no data flow in or out of the DTE serial port. A connection is disengaged when the counter reaches the preset value. Setting to S30 =0 disables the inactivity timer. S36 0–7 Specifies the action to take in the event of a negotiation failure when error control is selected. (See S48) S37 0–19 0 Sets the desired DCE speed (line speed).
0 Attempt to connect at the last “AT” speed 3 Attempt to make a 300 bps connection 5 Attempt to make a 1200 bps connection 6 Attempt to make a 2400 bps connection 7 Attempt to make a 4800 bps connection 8 Attempt to make a 7200 bps connection 9 Attempt to make a 9600 bps connection 10 Attempt to make a 12000 bps connection 11 Attempt to make a 14400 bps connection 12 Attempt to make a 16800 bps connection 13 Attempt to make a 19200 bps connection 14 Attempt to make a 21600 bps connection 15 Attempt to make a 24000 bps connection 16 Attempt to make a 26400 bps connection 17 Attempt to make a 28800 bps connection 18 Attempt to make a 31200 bps connection 19 Attempt to make a 33600 bps connection S38 0–23 Sets “downstream” data rate where K56 provides rates of 32,000 to 56,000 in 2,000 bps increments, V.90 provides rates of 28,000 to 56,000 bps in increments of 1,333 bps. 0 = V.90 disabled 1 = V.90 autorate K56 rates 2 = 28,000 bps 2 = 32,000 bps 3 = 29,333 bps 3 = 34,000 bps 4 = 30,666 bps 4 = 36,000 bps 5 = 32,000 bps 5 = 38,000 bps 6 = 33,333 bps 6 = 40,000 bps 7 = 34,666 bps 7 = 42,000 bps 8 = 36,000 bps 8 = 44,000 bps 9 = 37,333 bps 9 = 46,000 bps 10 = 38,666 bps 10 = 48,000 bps 11 = 40,000 bps 11 = 50,000 bps 12 = 41,333 bps 12 = 52,000 bps 13 = 42,666 bps 13 = 54,000 bps 14 = 44,000 bps 14 = 56,000 bps 15 = 45,333 bps 16 = 46,666 bps 17 = 48,000 bps 18 = 49,333 bps 19 = 50,666 bps 20 = 52,000 bps 21 = 53,333 bps Note:Upstream V.90 data rates are 22 = 54,666 bps 4800 to 33,600 bps in 2400 bps 23 = 56,000 bps increments.
S48 7 or 128 7 Enables (7) or disables (128) LAPM negotiation. The following table lists
Register Range Factory · Default Description

the S36 and S48 configuration settings for certain types of connections.
S48=7 S48=128 S36=0,2 LAPM or Hangup Do not use S36=1,3 LAPM or async Async S36=4,6 LAPM, MNP, or hangup MNP or hangup S36=5,7 LAPM,MNP or async MNP or async
S89 0, 5-255 10 (6.5 secs)
Sets the length of time, in 1-second increments, in the off-line command mode before the modem goes into standby mode (or sleep mode). A value of 0 prevents standby mode. A value of 1-4 sets the value to 5.
Register Range Factory · Default Description

In Command mode, the MultiMobile PC Card can send information and status responses (Result Codes) to your computer. Result Codes are used by communications programs and can also appear on your monitor. The form of the Result Code information displayed can be defined using the Qn, Vn, Wn, and Xn commands.
Terse Verbose Description 0 OK Command executed 1 CONNECT Modem connected to line 2 RING Ring signal detected 3 NO CARRIER Carrier signal lost or not detected 4 ERROR Invalid command 5 * CONNECT 1200 Connected at 1200 bps 6 NO DIALTONE No dial tone detected 7 BUSY Busy signal detected 8 NO ANSWER No answer at remote end 10 * CONNECT 2400 Connected at 2400 bps 11 * CONNECT 4800 Connected at 4800 bps 12 * CONNECT 9600 Connected at 9600 bps 13 * CONNECT 14400 Connected at 14400 bps 14 * CONNECT 19200 Connected at 19200 bps 24 * CONNECT 7200 Connected at 7200 bps 25 * CONNECT 12000 Connected at 12000 bps 26 * CONNECT 16800 Connected at 16800 bps 40 * CONNECT 300 Connected at 300 bps 55 * CONNECT 21600 Connected at 21600 bps 56 * CONNECT 24000 Connected at 24000 bps 57 * CONNECT 26400 Connected at 26400 bps 58 * CONNECT 28800 Connected at 28800 bps 59 * CONNECT 31200 Connected at 31200 bps 60 * CONNECT 33600 Connected at 33600 bps 70 * CONNECT 32000 Connected at 32000 bps 71 * CONNECT 34000 Connected at 34000 bps 72 * CONNECT 36000 Connected at 36000 bps 73 * CONNECT 38000 Connected at 38000 bps 74 * CONNECT 40000 Connected at 40000 bps 75 * CONNECT 42000 Connected at 42000 bps 76 * CONNECT 44000 Connected at 44000 bps 77 * CONNECT 46000 Connected at 46000 bps 78 * CONNECT 48000 Connected at 48000 bps 79 * CONNECT 50000 Connected at 50000 bps
* EC is added to these Result Codes when the extended Result Codes configuration option is enabled. EC is replaced by one of the following codes, depending on the type of error control connection: V42bis (V.42 error control [LAP-M] and V.42bis data compression); V42 (V.42 error control [LAP-M] only); MNP5 (MNP 4 error control and MNP 5 data compression); MNP4 (MNP 4 error control only); NoEC (No error control protocol).

Terse Verbose Description 80 * CONNECT 52000 Connected at 52000 bps 81 * CONNECT 54000 Connected at 54000 bps 82 * CONNECT 56000 Connected at 56000 bps 88 DELAYED Delay is in effect for the dialed number 89 BLACKLISTED Dialed number is blacklisted 90 BLACKLIST FULL Blacklist is full 100 CONNECT 28000 Connected at 28000 bps, V.90 rate 101 CONNECT 29333 Connected at 29333 bps, V.90 rate 102 CONNECT 30666 Connected at 30666 bps, V.90 rate 103 CONNECT 33333 Connected at 33333 bps, V.90 rate 104 CONNECT 34666 Connected at 34666 bps, V.90 rate 105 CONNECT 37333 Connected at 37333 bps, V.90 rate 106 CONNECT 38666 Connected at 38666 bps, V.90 rate 107 CONNECT 41333 Connected at 41333 bps, V.90 rate 108 CONNECT 42666 Connected at 42666 bps, V.90 rate 109 CONNECT 45333 Connected at 45333 bps, V.90 rate 110 CONNECT 46666 Connected at 46666 bps, V.90 rate 111 CONNECT 49333 Connected at 49333 bps, V.90 rate 112 CONNECT 50666 Connected at 50666 bps, V.90 rate 113 CONNECT 53333 Connected at 53333 bps, V.90 rate 114 CONNECT 54666 Connected at 54666 bps, V.90 rate
* EC is added to these Result Codes when the extended Result Codes configuration option is enabled. EC is replaced by one of the following codes, depending on the type of error control connection: V42bis (V.42 error control [LAP-M] and V.42bis data compression); V42 (V.42 error control [LAP-M] only); MNP5 (MNP 4 error control and MNP 5 data compression); MNP4 (MNP 4 error control only); NoEC (No error control protocol).

Chapter 5 – Troubleshooting
Chapter 5 – Troubleshooting Chapter 5 – Troubleshooting Chapter 5 – Troubleshooting Chapter 5 – Troubleshooting
This chapter provides general and specific problem solving steps. Below are a number of examples of problems, probable causes, and solutions. If your MultiMobile PC Card is not working properly, look up the problem and solution here. If you cannot solve the problem, Technical Support (see the Copyright page – it’s the page after the cover). There are some specific steps for resolving IRQ and COM port conflicts listed at the end of this chapter.

Chapter 5 – Troubleshooting
The Software Does Not Control the Modem Properly or Cannot Detect the Modem
Solution: If you can’t see the typed characters, then type ATE1 then press Enter.
The Modem Does Not Dial a Phone Number After AT Dial Command Execution

Chapter 5 – Troubleshooting
The Modem Speaker Does Not Make Any Sound When Connecting to Another Modem
Solution: Try to use V.42 or MNP2-4 if possible. Solution: Connect the modems at a slower baud rate.
After Downloading a File, the File Does Not Store on the Disk Drive

Chapter 5 – Troubleshooting
When Connecting to Another Modem, the Modem Reports a Higher Baud Rate Than It’s Really Using
If you have isolated a problem to an IRQ or COM port conflict, refer to the following sections for resolving IRQ and COM port conflicts in Windows 95/98.
If another device is using the same address range or IRQ, it will appear in the Conflicting Device List.
If you need to open your computer to change switches or jumpers on the conflicting device, refer to the device’s documentation.

Appendix A – Regulatory Compliance
Appendix A – Regulatory Compliance Appendix A – Regulatory Compliance Appendix A – Regulatory Compliance Appendix A – Regulatory Compliance
FCC Part 15 Regulation FCC Part 15 Regulation FCC Part 15 Regulation FCC Part 15 Regulation
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
This device complies with Part 15 of the FCC rules. Operation of this device is subject to the following conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference that may cause undesired operation.
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Reglement Canadien sur le matériel brouilleur.
Industry Canada

Appendix A – Regulatory Compliance
FCC Part 68 Telecom FCC Part 68 Telecom FCC Part 68 Telecom FCC Part 68 Telecom
4. The ringer equivalence number (REN) is used to determine the number of devices that may be connected to the telephone line. Excessive RENs on the telephone line may result in the device not ringing in response to an incoming call. In most, but not all, areas the sum of the RENs should not exceed 5.0. To be certain of the number of devices that may be connected to the line, as determined by the total RENs, contact the local telephone company.
Manufacturer: Multi-Tech Systems, Inc. Trade Name MultiMobile Model Number: MT5634ZLX, MT5634ZLXI, MT5634ZLX/FE FCC Registration No: MT5634ZLX: AU7USA-31371-MM-E MT5634ZLXI, MT5634ZLX/FE: AU7USA-32497-M5-E Ringer Equivalence: MT5634ZLX: 0.7B MT5634ZLXI, MT5634ZLX/FE: .04B Modular Jack (USOC): RJ-11 Service Center in USA: Multi-Tech Systems, Inc.
2205 Woodale Drive Mounds View, MN 55112 U.S.A. (763) 785-3500 (763) 785-9874 Fax

Appendix A – Regulatory Compliance
Notice: The ringer equivalence number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the ringer equivalence numbers of all the devices does not exceed 5.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.
MT5634ZLXI, MT5634ZLX/FE Modem MT5634ZLXI, MT5634ZLX/FE Modem MT5634ZLXI, MT5634ZLX/FE Modem MT5634ZLXI, MT5634ZLX/FE Modem Restrictions
Some dialing and answering defaults and restrictions may vary for international modems. Changing settings may cause a modem to become non-compliant with national telecom requirements in specific countries. Also note that some software packages may have features or lack restrictions that may cause the modem to become non-compliant.
EMC, Safety, and R&TTE Directive EMC, Safety, and R&TTE Directive EMC, Safety, and R&TTE Directive EMC, Safety, and R&TTE Directive Compliance
The CE mark is affixed to this product to confirm compliance with the following European Community Directives:
Council Directive 89/336/EEC of 3 May 1989 on the approximation of the laws of Member States relating to electromagnetic compatibility;
Council Directive 73/23/EEC of 19 February 1973 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits;
Council Directive 1999/5/EC of 9 March on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity.
and · and

Appendix A – Regulatory Compliance
New Zealand Telecom Warning Notice New Zealand Telecom Warning Notice New Zealand Telecom Warning Notice New Zealand Telecom Warning Notice
1. The grant of a Telepermit for any item of terminal equipment indicates only that Telecom has accepted that the item complies with minimum conditions for connection to its network. It indicates no endorsement of the product by Telecom, nor does it provide any sort of warranty. Above all, it provides no assurance that any item will work correctly in all respects with another item of Telepermitted equipment of a different make or model, nor does it imply that any product is compatible with all of Telecom’s network services.
This equipment is not capable under all operating conditions of correct operation at the higher speed which it is designated. 33.6 kbps and 56 kbps connections are likely to be restricted to lower bit rates when connected to some PSTN implementations. Telecom will accept no responsibility should difficulties arise in such circumstances.
Use of pulse dialing, when this equipment is connected to the same line as other equipment, may give rise to ‘bell tinkle’ or noise and may also cause a false answer condition. Should such problems occur, the user should not contact the Telecom Faults Service.
The preferred method of dialing is to use DTMF tones, as this is faster than pulse (decadic) dialing and is readily available on almost all New Zealand telephone exchanges.
For repeat calls to the same number:
For automatic calls to different numbers:
South African Statement South African Statement South African Statement South African Statement This modem must be used in conjunction with an approved surge protection device.

Appendix B – Global Wizard
Appendix B – Global Wizard Appendix B – Global Wizard Appendix B – Global Wizard Appendix B – Global Wizard
Before using your modem, or if you operate your modem from a country different than where it was originally set up, you must configure it for country-specific operation. If you are using Windows 95, 98, NT, Me, 2000, or XP, you may quickly and easily configure your modem using Multi-Tech Systems Global Wizard configuration utility.
If you are using a non-Windows operating system, or if you prefer to configure your Windows based modem using AT commands, follow the procedure titled, "Configuring Your Modem for Country-Specific Operation" in Chapter 2.
Using the Global Wizard Using the Global Wizard Using the Global Wizard Using the Global Wizard
Run Global Wizard allows you to configure your modem by running Multi-Tech’s Global Wizard configuration utility from the CD. If you select this option, continue with Step 4.
If you plan to use your computer from different countries, you may want to select Install Global Wizard to install the configuration utility to your hard drive and add the Global Wizard to your Start Menu.
After installing the Global Wizard, you may use the program by selecting Start | Programs | Global Wizard. Continue with Step 4.
Click Next>.
Click Next>.
Click OK to continue.
Click Next>.

Appendix B – Global Wizard
If the correct country is displayed, click Next> to continue; otherwise, click the <Back button and make the appropriate country selection.
Click Finish to exit the Global Wizard. Your modem is ready to use.

Appendix C – Flash Wizard
Appendix C – Flash Wizard Appendix C – Flash Wizard Appendix C – Flash Wizard Appendix C – Flash Wizard
Your modem is controlled by semi-permanent software, called firmware, which is stored in flash memory. Firmware is nonvolatile; that is, it remains stored in memory when the modem is turned off. However, either the manufacturer or the user can change the firmware as bugs are repaired or new features are added.
Multi-Tech System’s Flash Wizard utility can be used in the Windows operating system to update (flash) your modem’s firmware.
The Flash Wizard utility is available on the MultiMobile CD or can be downloaded from Multi-Tech’s Web site. Upgrade Procedures Upgrade Procedures Upgrade Procedures Upgrade Procedures
The upgrade (flash) procedure for the Windows operating system consists of the following steps, which are described in greater detail later in the chapter:
You must know the model number and firmware version of your Multi-Tech modem to know whether you should update it.
LT V.90 1.0 MT5634ZLXI PCMCIA Data/Fax Modem Version 1.16f

Appendix C – Flash Wizard
Identify the current version of the firmware available for your modem on the Multi-Tech web site. If your modem already has the current firmware, there is no need to update it.
You may install the Flash Wizard upgrade utility from the MultiMobile Modem CD.

Appendix C – Flash Wizard
Before you flash your modem it is important that you send the AT&W1Z command to it to clear out any stored parameters. You should also record the parameters that are currently stored in your modem so you can reprogram it after flashing.
To disable RAS and your Fax service (Windows NT Only):
Upgrading the Modem’s Firmware Using the Flash Wizard
4. Next, the Firmware Update Wizard displays current firmware version information. The top portion of the window provides port, version and country identification for the firmware currently installed on your device(s). The Hex File list box displays the firmware versions available for updating your modem. a. If your modem’s firmware version number matches or is higher than the version number listed in the Hex File list, click Cancel to end the update process. b. If your modem’s firmware version number is lower than the firmware version shown in the Hex File list, continue with the update process. Select the port for the device you are updating. Use the list box to select the latest .Hex file version number for your country and click Next>.
Your modem has been updated. You can now open your terminal program to reprogram your modem parameters or to confirm the update by typing ATi in a terminal window.

Appendix D – Technical Specifications
Appendix D – Technical Specifications Appendix D – Technical Specifications Appendix D – Technical Specifications Appendix D – Technical Specifications
Modem Standards: Data – V.34; V.90/56K Error Correction: V.42; MNP Class 2-4 Data Compression: MNP Class 5; V.42bis Fax: V.17, Group 3; Class 1 and Class 2
Dimensions: 2.0” w x 0.2” h x 3.4” d; 1.2 oz 5.1cm x 0.5 cm x 8.6 cm; 34g
12,000, 9600, 7200, 4800, 2400, 1200, 0-300 bps
Operating System Support:: Windows 98/Me/XP/NT/2000

Appendix E – Warranty and Repairs Policies
Appendix E – Multi-Tech Systems, Inc. Appendix E – Multi-Tech Systems, Inc. Appendix E – Multi-Tech Systems, Inc. Appendix E – Multi-Tech Systems, Inc.
Warranty & Repairs Policies Warranty & Repairs Policies Warranty & Repairs Policies Warranty & Repairs Policies
Multi-Tech Systems, Inc., (hereafter “MTS”) warrants that its products will be free from defects in material or workmanship for a period of two, five, or ten years (depending on model) from date of purchase, or if proof of purchase is not provided, two, five, or ten years (depending on model) from date of shipment.
MTS MAKES NO OTHER WARRANTY, EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.
This warranty does not apply to any products which have been damaged by lightning storms, water, or power surges or which have been neglected, altered, abused, used for a purpose other than the one for which they were manufactured, repaired by Customer or any party without MTS’s written authorization, or used in any manner inconsistent with MTS’s instructions.
MTS’s entire obligation under this warranty shall be limited (at MTS’s option) to repair or replacement of any products which prove to be defective within the warranty period or, at MTS’s option, issuance of a refund of the purchase price. Defective products must be returned by Customer to MTS’s factory – transportation prepaid.
MTS WILL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES, AND UNDER NO CIRCUMSTANCES WILL ITS LIABILITY EXCEED THE PRICE FOR DEFECTIVE PRODUCTS.
Repair Procedures for U.S. and Canadian Repair Procedures for U.S. and Canadian Repair Procedures for U.S. and Canadian Repair Procedures for U.S. and Canadian Customers
In the event that service is required, products may be shipped, freight prepaid, to our Mounds View, Minnesota factory:
Multi-Tech Systems, Inc. 2205 Woodale Drive Mounds View, MN 55112 Attn: Repairs, Serial #
A Returned Materials Authorization (RMA) is not required. Return shipping charges (surface) will be paid by MTS.
Please include, inside the shipping box, a description of the problem, a return shipping address (must have street address, not P.O. Box), your telephone number, and if the product is out of warranty, a check or purchase order for repair charges.
For out of warranty repair charges, go to www.multitech.com/documents/warranties
Extended two-year overnight replacement service agreements are available for selected products. Please call MTS at (888) 288-5470, extension 5308 or visit our web site at http://www.multitech.com/programs/orc/ for details on rates and coverage’s.

Appendix E – Warranty and Repairs Policies
Please direct your questions regarding technical matters, product configuration, verification that the product is defective, etc., to our Technical Support department at (800) 972-2439 or email tsupport@multitech.com. Please direct your questions regarding repair expediting, receiving, shipping, billing, etc., to our Repair Accounting department at (800) 328-9717 or (763) 717-5631, or email mtsrepair@multitech.com.
Repairs for damages caused by lightning storms, water, power surges, incorrect installation, physical abuse, or user-caused damages are billed on a time-plus-materials basis.
Your original point of purchase Reseller may offer the quickest and most economical repair option for your Multi-Tech product. You may also contact any Multi-Tech sales office for information about the nearest distributor or other repair service for your Multi-Tech product. http://www.multitech.com/COMPANY/offices/DEFAULT.ASP
In the event that factory service is required, products may be shipped, freight prepaid to our Mounds View, Minnesota factory. Recommended international shipment methods are via Federal Express, UPS or DHL courier services, or by airmail parcel post; shipments made by any other method will be refused. A Returned Materials Authorization (RMA) is required for products shipped from outside the U.S.A. and Canada. Please contact us for return authorization and shipping instructions on any International shipments to the U.S.A. Please include, inside the shipping box, a description of the problem, a return shipping address (must have street address, not P.O. Box), your telephone number, and if the product is out of warranty, a check drawn on a U.S. bank or your company’s purchase order for repair charges. Repaired units shall be shipped freight collect, unless other arrangements are made in advance.
Please direct your questions regarding technical matters, product configuration, verification that the product is defective, etc., to our Technical Support department nearest you or email tsupport@multitech.com. When calling the U.S., please direct your questions regarding repair expediting, receiving, shipping, billing, etc., to our Repair Accounting department at +(763) 717-5631 in the U.S.A., or email mtsrepair@multitech.com.
Repairs for damages caused by lightning storms, water, power surges, incorrect installation, physical abuse, or user-caused damages are billed on a time-plus-materials basis.
Repair Procedures for International Distributors
Procedures for International Distributors of Multi-Tech products are on the distributor web site. http://www.multitech.com/PARTNERS/login/
Copyright Multi-Tech Systems, Inc. 2001
10-Sep-01


Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.