External Data/Fax Modem
User's Guide


User Guide MT2834ZDX-Series S000309C Rev. C Copyright This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech Systems, Inc. All rights reserved.
Copyright © 2005 Multi-Tech Systems, Inc. Multi-Tech Systems, Inc. makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes. Revision Date Description A 09/15/03 Initial release of the User Guide for CD publication. B 09/15/04 Update the Warranty and Repairs statement with current URLs. C 08/22/05 Add WEEE Statement as Appendix D. Patents This device is covered by one or more of the following patents: 6,031,867; 6,012,113; 6,009,082; 5,905,794; 5,864,560; 5,815,567; 5,815,503; 5,812,534; 5,809,068; 5,790,532; 5,764,628; 5,764,627; 5,754,589; 5,724,356; 5,673,268; 5,673,257; 5,644,594; 5,628,030; 5,619,508; 5,617,423; 5,600,649; 5,592,586; 5,577,041; 5,574,725; 5,559,793; 5,546,448; 5,546,395; 5,535,204; 5,500,859; 5,471,470; 5,463,616; 5,453,986; 5,452,289; 5,450,425; D353,598; 5,355,365; 5,309,562; 5,301,274. Other patents pending. Trademarks Multi-Tech and the Multi-Tech logo are trademarks of Multi-Tech Systems, Inc. All other brand and product names mentioned in this publication are trademarks or registered trademarks of their respective companies. Technical Support Country By Email By Phone U.S. and Canada: support@multitech.com (800) 972-2439 World Headquarters Multi-Tech Systems, Inc. 2205 Woodale Drive Mounds View, Minnesota 55112 U.S.A. (763) 785-3500 or (800) 328-9717 Fax (763) 785-9874 http://www.multitech.com



Chapter 1 – Introduction and Installation
Installation
Getting Started
This guide shows you step-by-step how to set up your Multi-Tech MT2834ZDX–Series modem. For detailed information on how to install, test, and use your modem, see the User Guide, located on the MT2834ZDX system CD provided with your modem. Safety Warnings

Chapter 1 – Introduction and Installation
The modem comes with a set of self-adhesive plastic feet, which you can optionally attach to the modem. To install, simply peel them from their paper strip and press them into the recesses on the bottom of the modem.
Turn off your computer. Place the modem in a convenient location, and then connect it to your computer’s serial port, the phone line, AC power, and your phone.


Plug one end of the serial cable into the RS232 connector on the modem, and the other end into a serial port connector on your computer, such as COM1 or COM2.
Plug one end of the phone cable into the MT2834ZDX’s LINE jack and the other end into a phone line wall jack. Note: The LINE jack is not interchangeable with the PHONE jack. Do not plug the phone into the LINE jack or the line cable into the PHONE jack.
You may optionally plug a telephone into the PHONE jack. This jack is provided as a convenience; you may also plug a telephone into a duplex jack inserted into your wall jack.
Plug the power supply module into an AC power outlet or power strip. Plug the power supply’s cable into the POWER jack on the modem. Note: Use only the power supply supplied with the MT2834ZDX. Use of any other power supply will void the warranty and could damage the modem.
Test the modem by turning it on (a power on/off switch is located on the right side). When you apply power, the modem performs a diagnostic self-test, indicated by the speed indicators flashing in se- quence for a second or two, after which the 28 indicator should light. If this does not happen, check that the power switch is on, the power supply is solidly connected, and the AC outlet is live. If these measures do not work, see the Troubleshooting chapter..

Chapter 1 – Introduction and Installation
If you use Windows 98+, you must install the modem driver, which is installed using the Windows Plug and Play feature. Follow the four-step procedure below. If you use another operating system, see the Appendix.
1. Make sure your modem is connected properly, and then turn on your computer. Windows should detect your new modem and open the Install New Modem wizard. 1. Insert the system CD, and then click OK. 2. Windows installs and configures the modem. 3. Click Finish to exit. For Windows NT, the Install New Modem wizard presents one additional prompt before Step 2. At this prompt, select: Don’t detect my modem; I will select it from a list, and then click Next. A dialog box with a list of manufacturers and a list of modem models appears. Select your modem. Continue with Step 2 above. Note: If Windows cannot identify your modem (for instance, if it identifies your modem as a “Standard Modem”), click Change. A dialog box with a list of manufacturers and a list of modems appears.
Data communications software is designed to send and receive messages. Multi-Tech includes PhoneTools communications software with your modem. However, the modem will work with most data communications software. To install PhoneTools, insert the CD into the CD-ROM drive; click the PhoneTools icon. You will be asked to choose your language. The software automatically loads onto your PC. Removing Your Old Modem from Windows When a new modem replaces another modem, the old modem installation remains in Windows after you install the new modem, and the old modem is still selected in HyperTerminal and other Windows applications. Although you can change the application connection descriptions one at a time, it is easier to force Windows applications to use the new modem by removing the old modem from Windows. 1. Click the Start button, point to Settings, and click Control Panel. 2. Double-click the Modems icon to open the Modems Properties dialog box. 3. In the list box, select the old modem. 4. Click Remove, then click Close. 5. The next time you dial a HyperTerminal connection, it will select your new modem and ask you to confirm the selection.

Chapter 2 – Operation
Front Panel

The MT2834ZDX has ten LED indicators on the front panel that indicate status, configuration, and activity: Transmit Data. The TD LED lights when the modem is transmitting data to another modem. The state of the LED matches the TD circuit on pin 2 of the RS-232C/V.24 interface. Receive Data. The RD LED lights when the modem is receiving data from another modem. The state of the LED matches that of the RD circuit on pin 3 of the RS-232C/V.24 interface. Carrier Detect. The CD LED lights when the modem detects a valid carrier signal from another modem. It is on when the modem is communicating with the other modem and off when the link is broken. 33,600 bps. The 33 LED lights by itself when the modem connects 33,600 bps operation. This LED also lights or blinks in combination with the 14 LED to indicate speeds between 16,800 and 26,400 bps (see table). 14,400 bps. The 14 LED lights by itself when the modem connects at 14,400 bps. The 14 LED lights or blinks in combination with the 28 LED to indicate speeds between 16,800 and 26,400 bps. It lights together with the 96 LED to indicate a speed of 12,000 bps. 9600 bps. The 96 LED lights when the modem connects at 9600 bps. If no speed LED lights, the modem is operating at less than 9600 bps. Off-Hook. The OH LED lights when the modem is off-hook, which occurs when the modem is dialing, online, or answering a call. The LED flashes when the modem pulse-dials. Terminal Ready. The TR LED lights when a datacomm program initializes the modem. It means the modem is ready for an outgoing or incoming call. It goes off when the datacomm program disconnects the COM port. When it goes off, a connected modem will disconnect. The state of the TR LED matches that of the DTR circuit on pin 20 of the RS- 232C/V.24 interface. Error Correction (V.42). The EC LED lights continuously when the modem is in error correction mode, and blinks when compression is activated. Fax. The FX LED lights when the modem is in fax mode. Note: When you turn on the MT2834ZDX, the speed lights flash briefly as the modem does a self-test, then the LED for the default modem baud rate lights. The default rate for the MT2834ZDX is 28,800 bps (33,600 bps for the ZDXb) unless you select and store another baud rate. After a call, the LEDs for the connection’s baud rate remain lit until another call is made or the modem is reset. If you connect at a rate under 9600 bps, all speed LEDs remain off after the connection is broken, even though the modem is still turned on. Speed Indicator Blink Rates The 33, 14, and 96 speed indicators light singly or in combination to indicate data rates.

Registers and Result Codes
AT Commands
This section summarizes the AT commands for this modem. Command: AT Attention Code Values: n/a Description: The attention code precedes all command lines except A/, A:, and escape codes. Command: RETURN Key Values: n/a Description: Press the RETURN (ENTER) key to execute most commands. Command: A Force Answer Mode Values: n/a Description: Answer call before final ring. Command: A/ Repeat Last Command Values: n/a Description: Do not precede this command with AT. Do not press RETURN to execute. Command: A: Continuous Redial Values: n/a Description: Redial last number until answered (10 redials in DOC modems). Do not precede this command with AT or press RETURN to execute. Command: &An Answerback Values: n = 0 or 1 Default: 0 Description: &A0 Disables answerback. &A1 Enables answerback reply to an ID request. Command: $An Auto-Reliable Buffering Values: n = 0 or 1 Default: 0 Description: $A0 Discard data received during establishment of a reliable connection. $A1 Buffer data received during establishment of a reliable connection. Command: #An Auto Speed Detection in Answer Mode Values: n = 0–3 Default: 0 Description: #A0 Start at maximum speed and fall back to a lower speed (26400, 24000, 21600, 19200, 16800, 14400, 12000, 9600, 7200, 4800, 2400, 1200, or 300 bps) as line conditions warrant. #A1 Maximum speed only. #A2 Start at maximum speed and fall back decrementally to 4800 bps only. #A3 Start at 2400 bps and fall back to 1200 to 300 bps only. Command: &BSn Maximum Reliable Block Size Values: n = 0 or 1 Default: 1 Description: &BS0 Maximum transmit block size of 64 characters. &BS1 Maximum transmit block size of 256 characters.

Command: $BAn Baud Adjust Values: n = 0 or 1 Default: 0 Description: $BA0 Set baud adjust off, speed conversion on. (Serial port speed is independent of modem data rate.) $BA1 Set baud adjust on, speed conversion off. (Serial port speed is same as modem data rate.) Command: &Cn Carrier Detect Control Values: n = 0, 1, 2, or 4 Default: 1 Description: &C0 Force Carrier Detect high. &C1 Let Carrier Detect follow carrier signal. &C2 Let Carrier Detect drop on disconnect, then go high again (for some CBX phone systems). &C4 Reset modem when Carrier Detect drops. Command: &CDn Cleardown at Disconnect Values: n = 0, 1 Default: 0 Description: &CD0 Execute a cleardown at disconnect. &CD1 Do not execute a cleardown at disconnect. Command: Ds Dial Values: s = dial string (phone number and dial modifiers) Default: none Description: Dial telephone number s, where s may include up to 60 digits and T, P, R, comma, colon, and semicolon characters. Command: DsNd Store Telephone Number Values: s = dial string (phone number and dial modifiers) d = 0 or 1 Default: none Description: To store, enter D followed by dial string s, then N followed by directory number d. Example: ATDT9,5551212N1. Command: &Dn Data Terminal Ready Control Values: n = 0–3 Default: 2 Description: &D0 Modem ignores DTR signal. &D1 When DTR drops, the modem hangs up. While DTR is low, the modem accepts commands but will not dial or auto-answer until DTR goes high again. &D2 Same as &D1. &D3 When DTR drops, the modem hangs up and resets as if an ATZ command were issued. Command: $Dn DTR Dialing Values: n = 0 or 1 Default: 0 Description: $D0 Do not dial when DTR goes high. $D1 Dial stored number N0 when DTR goes high. Command: %DCn AT Command Control Values: n = 0 or 1 Default: 0 Description: %DC0 The modem responds to AT commands. %DC1 The modem ignores AT commands. Note: The modem will respond to AT%DC for 10 seconds after power-up. Command: %DFn Format Line Probe Data Values: n = 0 or 1 Default: 0 Description: %DF0 Display data in graph format. Y axis is gain shown in dBm. %DF1 Display data in table format. Gain is shown numerically in dBm at 75Hz increments from 150Hz to 3750Hz.

Command: %DPn Read Line Probe Data Values: n = 0 or 1 Default: 0 Description: %DP0 Do not read and store line probe information from DSP during handshake. %DP1 Read and store line probe information from DSP during handshake. Command: >DTn DTMF Detection Values: n = 0 or 1 Default: 0 Description: >DT0 The modem will not detect DTMF tones. >DT1 The modem will detect and report DTMF tones when it is off-hook. Command: En Echo Command Mode Characters Values: n = 0 or 1 Default: 1 Description: E0 Do not echo keyboard input to the terminal. E1 Do echo keyboard input to the terminal. Command: &En V.42 Error Correction Modes Values: n = 0, 1, or 2 Default: 1 Description: &E0 V.42 non-error correction mode (V.42 disabled). &E1 V.42 auto-reliable mode. &E2 V.42 reliable mode (V.42 enabled). Command: &En Modem-Initiated Flow Control Values: n = 3, 4, or 5 Defaults: 4 Description: &E3 Flow control disabled. &E4 CTS/RTS hardware flow control. &E5 XON/XOFF software flow control. Command: &En XON/XOFF Pass-Through Values: n = 6 or 7 Defaults: 6 Description: &E6 Respond to and discard XON/XOFF characters when &E5 is selected. &E7 Respond to and pass through XON/XOFF characters when &E5 is selected. Command: &En Hewlett Packard ENQ/ACK Pacing Values: n = 8 or 9 Default: 8 Description: &E8 Ignore ENQ/ACK pacing characters. &E9 Respond to ENQ/ACK pacing characters. Command: &En Non-Error Correction Mode Flow Control Values: n = 10 or 11 Default: 10 Description: &E10 Disable non-error correction mode flow control. &E11 Enable non-error correction mode flow control. Command: &En Pacing (Computer-Initiated Flow Control) Values: n = 12 or 13 Default: 13 Description: &E12 Pacing disabled. &E13 Pacing enabled. Command: &En Data Compression Values: n = 14 or 15 Default: 15 Description: &E14 Data compression disabled. &E15 Data compression enabled.

Command: $En V.42 Error Correction at 300 bps Values: n = 0 or 1 Default: 0 Description: $E0 V.42 error correction at 300 bps disabled. $E1 V.42 error correction at 300 bps enabled. Command: $EBn Asynchronous Word Length Values: n = 0 or 1 Default: 0 Description: $EB0 10-bit mode enabled. $EB1 11-bit mode enabled. Command: %En Escape Sequence Options Values: n = 0–5 Defaults: 1 and 4 Description: %E0 Modem won’t escape. %E1 +++AT<CR> method. %E2 <BREAK>AT<CR> method. %E3 Both +++AT<CR> and <BREAK>AT<CR> methods. %E4 No OK response to +++AT<CR>. %E5 OK response to +++AT<CR>. Command: &Fn Load Default Configurations Values: n = 0, 8, or 9 Default: 8 Description: &F0 Load factory default values from ROM if &F8 was previously stored; load user default values from non-volatile memory if &F9 was previously stored. &F8 Read factory default values when &F is issued (effective only if you store &F8 using &W0). &F9 Read values stored in non-volatile memory when &F is issued (effective only if you store &F9 using &W0). Command: $Fn Enable/Disable Auto-Reliable Fallback Character Values: n = 0 or 1 Default: 0 Description: $F0 Do not fall back to non-error correction mode connect if is received during handshake. $F1 Fall back to non-error correction mode connect if is received during handshake. Command: %Fn Echo Frequency Canceller Offset Compensation Values: n = 0 or 1 Default: 0 Description: %F0 Disable echo canceller frequency offset compensation. %F1 Enable echo canceller frequency offset compensation. Command: #Fn Fallback Modes When Online Values: n = 0, 1, or 2 Default: 2 Description: #F0 No fallback when on line. #F1 Fallback decrementally from maximum speed to 4800 bps as line conditions deteriorate. #F2 Fallback decrementally to 4800 bps; fall forward when line conditions improve. Command: &Gn Guard Tones Values: n = 0, 1, or 2 Default: 0 Description: &G0 Turn off ITU-T guard tones. &G1 Turn on ITU-T 550 Hz guard tone. &G2 Turn on ITU-T 1800 Hz guard tone. Note: The ZDXK is locked to the ITU-T 1800 Hz guard tone (&G2). Command: Hn On Hook/Off Hook Values: n = 0 or 1 Default: None Description: H0 Go on hook (hang up). H1 Go off hook.

Command: $Hn Help Screens Values: n = 1, 2, or 3 Default: None Description: $H1 Display Help Screen #1. $H2 Display Help Screen #2. $H3 Display Help Screen #3. Command: In Inquire Product Codes Values: n = 0, 1, or 2 Default: None Description: I0 Display modem ID number. I1 Display firmware version number. I2 Display modem description. Command: $Jn Display Parity Bit Values: n = 0, 1 Default: 0 Description: The $J command allows the parity bit to be seen when XON/OFF flow control is enabled (see the &E command.) $J0 disables the display of the parity bit to be seen when XON/XOFF flow control is enabled. $J1 enables the display of the parity bit to be seen when XON/XOFF flow control is enabled. Command: Ln List Commands Values: n = 0, 5–8 Default: None Description: L List stored telephone numbers. L5 List current operating parameters. L6 List current S-register values. L7 List additional current operating parameters. L8 List DSP code version number, processor speed, and online diagnostic parameters. L9 List signal strength information. L10 List signal to noise ratio information (SNR). L11 List noise information. Note: For L9, L10, and L11, you must first type +++AT<CR> (online escape command while maintaining command mode), then type the command prefixed by an AT (e.g., ATL10). Command: #Ln V.42 Mode Selection in Originate Mode Values: n = 0, 1, 2, or 3 Default: 0 Description: #L0 Modems negotiate V.42 mode. #L1 MNP on & LAP-M off. #L2 LAP-M on & MNP off. #L3 Disable detection phase and go directly to LAP-M. Command: Mn Modem Speaker Control Values: n = 0, 1, 2, or 3 Default: 1 Description: M0 Speaker always off. M1 Speaker on until carrier signal detected. M2 Speaker always on. M3 Speaker on during dialing, off during handshaking.

Command: $MBn Modem Baud Rate Values: n = speed Default: 28800 (ZDX) or 33600 (ZDXb) Description: $MB300 Originate call at 300 bps. $MB1200 Originate call at 1200 bps. $MB2400 Originate call at 2400 bps. $MB4800 Originate call at 4800 bps. $MB7200 Originate call at 7200 bps. $MB9600 Originate call at 9600 bps. $MB14400 Originate call at 14,400 bps. $MB16800 Originate call at 16, 800 bps. $MB19200 Originate call at 19,200 bps. $MB28800 Originate call at 28,800 bps. $MB33600 Originate call at 33,600 bps (ZDXb only). Command: Nd Dial a Stored Number Values: d = 0 or 1 Default: None Description: Dial stored telephone number d. Command: NdNe. .. Number Linking Values: d = 0 or 1; e = 1 or 0 Default: None Description: Dial stored number d; if it is busy, dial stored number e. Command: O Go Back Online Values: n/a Description: Return to online mode after you have used an escape sequence to go from online mode to command mode. Command: P Pulse Dial Values: n/a Default: Yes Description: The modem pulse-dials numbers that follow P in the dialing command. Command: &Pn Set Pulse Dial Ratios Values: n = 0 or 1 Default: 0 Description: &P0 60:40 break/make pulse ratio. &P1 67:33 break/make pulse ratio. Note: The ZDXK is locked to a 67:33 pulse ratio (&P1). Command: Qn Result Codes Enable/Disable Values: n = 0, 1, or 2 Default: 0 Description: Q0 Enable result codes. Q1 Disable result codes (quiet). Q2 Enable no-response answer mode, which leaves originate mode intelligent while turning off answer mode responses and echo. Command: &Qn Multi-Tech or Standard Result Codes Values: n = 0 or 1 Default: 0 Description: &Q0 Multi-Tech responses with modifiers. &Q1 Standard AT responses with no modifiers. Command: Rn Reverse Originate/Answer Modes Values: n = 0 or 1 Default: 0 Description: R0 Modem will not reverse modes. R1 Modem will reverse modes when R is added to the dial string.

Command: &Rn Clear to Send Control Values: n = 0, 1, or 2 Default: 1 Description: &R0 Let CTS state follow RTS state when on line. &R1 Force CTS high (on). &R2 Let CTS drop on disconnect for time set by S24, then go high again. Command: &RAn Asymmetrical Bit Rate Values: n = 0 or 1 Default: 0 Description: &RA0 Enable asymmetrical bit rate in V.34 mode. &RA1 Disable asymmetrical bit rate in V.34 mode. Command: &RDn Square Wave Ring Detect Values: n = 0 or 1 Default: 1 Description: &RD0 Modem detects only sine wave rings. &RD1 Modem detects both sine and square wave rings. Command: &RFn CTS/RTS Interaction Control Values: n = 0 or 1 Default: 1 Description: &RF0 Let CTS follow RTS. &RF1 Let CTS act independently (use with &R). Command: &RN Rate Negotiation Values: n/a Description: Forces the modem to perform a rate renegotiation while on line. You must escape to command mode to issue this command. Command: &RP Immediate Line Probe Values: n/a Description: Initiates a retrain that makes the processor read line probe information if %DP1 is selected. Valid only when on line in V.34 mode. Command: &RR Immediate Retrain Values: n/a Description: Forces the modem to perform an immediate retrain while on line. You must escape to command mode to issue this command. Command: $Rn Retransmit Count Values: n = 0 or 1 Default: 0 Description: $R0 Disconnect after 50 retransmits of a data block. $R1 Do not disconnect after 50 retransmits. Command: Sr=n Set Register Value Values: r = S-register number; n varies Default: None Description: Set value of register S r to value of n, where n is entered in decimal format. Command: Sr? Read Register Value Values: r = S-register number Default: None Description: Read value of register S r and display value in 3- digit decimal form. Command: &Sn Data Set Ready Control Values: n = 0, 1, or 2 Default: 1 Description: &S0 Force DSR high (on). &S1 Let DSR follow CD. &S2 DSR drops on disconnect, then goes high again. (Used by some CBX phone systems.)

Command: &SFn DSR/CD Interaction Control Values: n = 0 or 1 Default: 0 Description: &SF0 Select DSR to follow CD. &SF1 Select DSR to be independent. Command: $SBn Serial Port Baud Rate Values: n = speed Default: 57600 Description: $SB300 Set serial port to 300 bps. $SB1200 Set serial port to 1200 bps. $SB2400 Set serial port to 2400 bps. $SB4800 Set serial port to 4800 bps. $SB9600 Set serial port to 9600 bps. $SB19200 Set serial port to 19200 bps. $SB38400 Set serial port to 38400 bps. $SB57600 Set serial port to 57600 bps. $SB115200 Set serial port to 115200 bps. Note: Baud adjust must be off ($BA0) to enable fixed baud rate. Command: T Tone-Dial Values: n/a Default: P command Description: Modem will tone-dial numbers following a T in the dialing command. Command: &Tn Respond to Remote Digital Loopback Signal Values: n = 4 or 5 Default: 5 Description: &T4 Enable response to remote digital loopback signal. &T5 Disable response to remote digital loopback signal. Command: #Tn Trellis-Coded Modulation Values: n = 0 or 1 Default: 1 Description: #T0 Disable trellis-coded modulation. #T1 Enable trellis-coded modulation. Command: Un Loopback Test Modes Values: n = 0, 1, 2, or 3 Default: None Description: U0 Enable local nalog loopback originate mode. U1 Enable local analog loopback answer mode. U2 Enable remote digital loopback mode. U3 Enable local digital loopback mode. Command: Vn Result Codes (Verbose/Terse) Values: n = 0 or 1 Default: 1 Description: V0 Result codes sent as digits (terse response). V1 Result codes sent as words (verbose response). Command: #Vn V.32terbo Handshake Tones Values: n = 0 or 1 Default: 1 Description: #V0 Include V.32terbo tones in handshake. #V1 Exclude V.32terbo tones from handshake. Command: W Wait for New Dial Tone Values: n/a Description: Inserted in dialing command, causes modem to wait for a new dial tone. (X2 or X4 must be selected.)

Command: &Wn Store Configuration Values: n = 0 or 1 Default: 1 Description: &W0 Store current settings in NVRAM; load them at power-on or following the ATZ command instead of loading the factory defaults from ROM. W1 Clear user default settings from NVRAM. Command: Xn Result Codes and Call Progress Selection Values: n = 0–4 Default: 0 Description: X0 Basic result codes ( CONNECT only); does not look for dial tone or busy signal. X1 Extended result codes ( CONNECT 28800, CONNECT 33600, etc.); does not look for dial tone or busy signal. X2 Extended result codes with NO DIALTONE; does not look for busy signal. X3 Extended result codes with BUSY; does not look for dial tone. X4 Extended result codes with NO DIALTONE and BUSY. Command: #Xn Number of XOFF Characters Sent Values: n = 0 or 1 Default: 0 Description: #X0 Single XOFF character sent after buffer is full. #X1 Multiple XOFF characters sent (one for every character received after buffer is full). Command: Yn Long Space Disconnect Values: n = 0 or 1 Default: 0 Description: Y0 Disable sending or responding to long space break signal on disconnect. Y1 Enable sending or responding to long space break signal on disconnect. (Both modems must have Y1 set.) Command: Z Modem Reset Values: n/a Description: Reset modem to default values. Defaults come from user NVRAM if &W0 is set, from factory ROM if &W1 is set. Command: , Dialing Pause Values: n/a Description: Placed in dialing command, comma causes dialing pause for time set by S8. Command: : Continuous Redial Values: n/a Description: Placed at end of dial command, a colon causes continuous redial of a number (10 in DOC modems) until answered. Not used in ZDXK or ZDXI modems. Command: ; Return to Command Mode Values: n/a Description: Placed at end of dial command, a semicolon causes an immediate return to command mode after dialing. Command: ! Flash On-Hook Values: n/a Description: Placed in dial command, exclamation point causes modem to flash on-hook. Command: @ Quiet Answer Values: n/a Description: Placed in dial command, @ causes modem to wait for a ringback, then 5 seconds of silence, before processing next part of command. Command: $ Call Card Tone Detect Values: n/a Description: Placed in dial command, causes modem to wait for a call card tone before processing next part of command (such as a call card number).

Command: %%%AT<CR> Remote Configuration Escape Sequence Values: n/a Description: Initiates remote configuration mode while online with remote modem. The remote configuration escape character (%) is defined in register S13. Command: +++AT<CR> Escape Code Values: n/a Description: Puts modem in command mode (and optionally issues a command) while remaining on line. Enter +++AT, up to ten command characters (or as defined by S34), and a RETURN. Used mostly to issue hang-up command: +++ATH<CR>. Command: <BREAK>AT<CR> Escape Sequence Values: n/a Description: Alternate escape method. Puts modem in command mode while remaining on line. Send a <BREAK> signal followed by AT, up to sixty command characters, and a RETURN. You must set the modem to %E2 or %E3 before you can use this escape method.

S-Registers Certain modem values, or parameters, are stored in memory locations called S-registers. Use the S command to read or to alter the contents of S-Registers (see previous section).
Register Unit Range Default Description S0 1 ring 0, 1–255 1 Sets the number of rings until the modem answers. ATS0=0 disables autoanswer completely. S1 1 ring 0–255 0 Counts the rings that have occurred. S2 decimal 0–127 43(+) Sets ASCII code for the escape code character. S3 decimal 0–127 13 (^M) Sets ASCII code for the RETURN character. S4 decimal 0–127 10 (^J) Sets ASCII code for the LINE FEED character. S5 decimal 0–127 8 (^H) Sets ASCII code for the BACKSPACE character. S6 1 sec. 2–255 2 Sets the time the modem will wait for a dial tone before aborting a call. S7 1 sec. 1–255 45 Sets the time the modem. S8 1 sec. 0–255 2 Sets the length of a pause caused by a comma character in a dialing command. S9 100 ms 1–255 6 Sets delay between when the modem detects a valid carrier signal and when it turns on its CD circuit. S10 100 ms 1–254 7 Sets how long a carrier signal must be lost before the modem disconnects. S10=255 causes the modem to not disconnect with loss of carrier. S11 1 ms 1–255 70 Sets spacing and duration of dialing tones. Recommended minimum is 50 ms. S13 decimal 0, 1–127 37 (%) Sets ASCII code for remote configuration escape character. S13=0 disables remote configuration. S17 10 ms 1–255 25 Sets the length of the break time (space) sent to the local PC when the modem receives a remote break. S24 50 ms 0–255 20 Sets the time the DSR, CTS, and CD signals drop before going high again. Used for some PBX and CBX phone systems. S25 100 ms 0, 1–255 0 Sets the time the DTR signal must be dropped before the modem disconnects. The 0 default equals 50 ms. S30 1 min. 0, 1–255 0 Sets how long the modem waits after the last character is received or transmitted before it disconnects. The 0 default disables the timer. S32 100 ms 0–255 20 Sets the time the modem will wait for a RETURN to be entered during escape sequence execution. S34 1 char 0–60 10 Sets the number of command characters allowed after +++AT. S36 1 sec. 0, 1-255 5 Sets the time between DTR inactive and modem offhook. S36=0 disables DTR busy-out. S37 1 sec. 0-255 5 Sets the time between DTR active and modem on-hook. S43 decimal 28, 26, 24, 21, 19, 16, 14, 12, 96, or 48
0 Sets fixed V.34 connect speed. 28 = 28800 bps; 26 = 26400 bps; 48 = 4800 bps. 0 default disables this feature.
S48 decimal 33, 31, 28, 26, 24, 21, 19, 16, 14, 12, 96, or 48
0 Sets maximum V.34 connect speed. 33 = 33600 bps; 31 = 31200 bps;…48 = 4800 bps. 0 default disables feature (same as S48=33).

In command mode the MT2834ZDX can send responses, or result codes, to your computer. Result codes are used by communications programs and can also appear on your monitor.
AT&Q0 selects Multi-Tech result codes with RELIABLE, LAPM, and COMPRESSED modifiers (default).
AT&Q1 selects standard AT result codes without modifiers.
&Q0 Multi-Tech Result Codes &Q1 Standard Result Codes Description Terse Verbose Terse Verbose 0 OK 0 OK Command executed without error 1 CONNECT 1 CONNECT Modem has detected carrier and gone online 2 RING 2 RING Modem has detected ring from incoming call 3 NO CARRIER 3 NO CARRIER No carrier has been signal detected within allowed time 4 ERROR 4 ERROR Error in command line (too many characters or invalid characters 5 * CONNECT 1200 5 CONNECT 1200 Modem has detected carrier at 2400bps and gone online 6 NO DIALTONE 6 NO DIALTONE No dial tone detected 7 BUSY 7 BUSY A busy signal detected 8 NO ANSWER 8 NO ANSWER Remote system did not answer 9 CONNECT 2400 Modem had detected carrier at 2400 bps and gone online 10 CONNECT 2400 Modem had detected carrier at 2400 bps and gone online 11 * CONNECT 4800 11 CONNECT 4800 Modem had detected carrier at 4800 bps and gone online 12 * CONNECT 9600 12 CONNECT 9600 Modem had detected carrier at 9600 bps and gone online 13 CONNECT 12000 13 CONNECT 12000 Modem had detected carrier at 12000 bps and gone online 13 * CONNECT 14400 13 CONNECT 14400 Modem had detected carrier at 14400 bps and gone online 16 CONNECT 16800 16 CONNECT 16800 Modem had detected carrier at 16800 bps and gone online 19 * CONNECT 19200 19 CONNECT 19200 Modem had detected carrier at 19200 bps and gone online 21 * CONNECT 21600 21 CONNECT 21600 Modem had detected carrier at 21600 bps and gone online 24 * CONNECT 24000 24 CONNECT 24000 Modem had detected carrier at 24000 bps and gone online 26 * CONNECT 26400 26 CONNECT 26400 Modem had detected carrier at 26400 bps and gone online 28 * CONNECT 28800 28 CONNECT 28800 Modem had detected carrier at 28800 bps and gone online 31 * CONNECT 31200 31 CONNECT 31200 Modem had detected carrier at 31200 bps and gone online 33 * CONNECT 33600 32 CONNECT 33600 Modem had detected carrier at 33600 bps and gone online *With error correction on, RELIABLE (or R) or LAPM (or L) is added to these result codes. With data compression on, COMPRESSED (or C) is added.

Chapter 4 – Troubleshooting
Your MultiModemZDX modem was thoroughly tested at the factory before it was shipped. If you are unable to make a successful connection, or if you experience data loss or garbled characters during your connection, it is possible that the modem is defective. However, it is more likely that the source of your problem lies elsewhere. The following symptoms are typical of problems you may encounter:

Chapter 4 – Troubleshooting
port setting in your software, and try again.
You can narrow the list of possibilities by using extended result codes. Extended result codes are enabled by default. If they have been disabled, include V1X4 in the modem’s initialization string, or in terminal mode enter ATV1X4 and press ENTER. When you dial again, the modem will report the call’s progress.

Chapter 4 – Troubleshooting

Chapter 4 – Troubleshooting

Appendix A – Regulatory Compliance
Regulatory Compliance
Regulatory Requirements for the United States

Appendix A – Regulatory Compliance
1. This equipment complies with Part 68 of the 47 CFR rules and the requirements adopted by the ACTA. Located on this equipment is a label that contains, among other information, the registration number and ringer equivalence number (REN) for this equipment or a product identifier in the format: For current products is US:AAAEQ##Txxxx. For legacy products is AU7USA-xxxxx-xx-x. If requested, this number must be provided to the telephone company. 2. A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable 47 CFR Part 68 rules and requirements adopted by the ACTA. It’s designed to be connected to a compatible modular jack that is also compliant. 3. The ringer equivalence number (REN) is used to determine the number of devices that may be connected to a telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to a line, as determined by the total RENs, contact the local telephone company. For products approved after July 23, 2001, the REN for this product is part of the product identifier that has the format US:AAAEQ##Txxxx. The digits represented by ## are the REN without a decimal point (e.g., 03 is a REN of 0.3). For earlier products, the REN is separately shown on the label. 4. If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn't practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. 5. The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service. 6. If trouble is experienced with this equipment, please contact Multi-Tech Systems, Inc. at the address shown below for details of how to have the repairs made. If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved. 7. Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information. 8. No repairs are to be made by you. Repairs are to be made only by Multi-Tech Systems or its licensees. Unauthorized repairs void registration and warranty. 9. If your home has specially wired alarm equipment connected to the telephone line, ensure the installation of this equipment does not disable your alarm equipment. If you have questions about what will disable alarm equipment, consult your telephone company or a qualified installer. 10. Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information. 11. This equipment is hearing aid compatible. 12. Manufacturing Information: Manufacturer: Multi-Tech Systems, Inc. Model Number: MT2834ZDX, MT2834ZDXb FCC Registration Number: AU7USA-20673-MM-E Ringer Equivalence Number: 0.3B Modular Jack (USOC): RJ11C or RJ11W (single line) Service Center in USA: Multi-Tech Systems, Inc.
2205 Woodale Drive Mounds View, MN 55112 (763) 785-3500 (763) 785-9874 Fax

Appendix A – Regulatory Compliance
Current Requirements for Label Content and Format Approved terminal equipment and approved protective circuitry shall prominently display the following information using the format shown below:
Labeling Continuity and Changes The labeling content and format requirements in effect when a product was approved shall be effective for the life of the product. The labeling content and format requirements in effect at approval shall also continue to be effective for modified products. However, the responsible party shall have the option of conforming a product's labeling to current content and format requirements at any time.
Other Label Requirements The label shall be placed in one of the following locations in a location where it can be found after installation:

Appendix A – Regulatory Compliance
The following requirements are established under section 69.3 of the Telecommunications Act for purposes of section 5 of the Telecommunications Apparatus Regulations. Registered equipment shall bear the following identifying marks, and the Declaring Party shall ensure that these marks are permanently affixed to the equipment:
(a) The registration number — Specifications of this mark are given in the document: Self-Marking of the
Certification/Registration Number on Terminal Equipment — Application Procedure and Agreement; and (b) The model identification number under which the product was registered. A statement of compliance with Industry Canada requirements, such as the one given below, shall accompany each unit of equipment whether registered under this procedure or previously certified:
"This product meets the applicable Industry Canada technical specifications" For terminal equipment intended for connection to loop-start or ground-start interfaces, the Ringer Equivalence Number (REN) must be calculated as per Section 1.8 of CS-03, Part I. A REN higher than that determined may be assigned by manufacturers to allow for production variations. The REN must be marked on the terminal equipment itself or added to the note below. A note similar to the following shall accompany each unit of equipment whether registered under this procedure or previously certified:
"The Ringer Equivalence Number is an indication of the maximum number of devices allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the RENs of all the devices does not exceed five". Pursuant to section 69.3 of the Telecommunications Act, Certified or self-declared TE will bear a valid identifying certification or registration number. The marking of the certification or registration number on the product shall be as follows:
(a) TAC holder/DP will be responsible for permanently affixing the certification/registration number on the
TE. The certification/registration number (see example below) identifies Certified or self-declared TE to the public, representatives of the telecommunications common carriers, the Department, and other interested parties. The letter height must be no less than 1.5 mm and the letters must be legible without magnification. (b) For integrated devices, e.g. a modem or one that is intended to become a sub-assembly of host
equipment e.g. a data terminal, computer etc. that are designed to interface directly with the network, the certification/registration number shall be affixed to the integrated device itself. (c) The certification/registration number for a packaged TE will denote that the total package has been
registered. However, the marking will normally be placed on that unit of the package, which connects to the network. For example, in a PBX, the marking will be placed on the common equipment, which connects to the network, rather than on plug-in components which may be added later. The Terminal Equipment List will show the common equipment but not the standard station apparatus or any proprietary station apparatus. (d) The marking format of the certification/registration number is as follows:

Appendix A – Regulatory Compliance
(e) Certification Numbers granted prior to the implementation of the above marking format are
grandfathered. (i) For previously certified TE, the self-marking format shall consist of the old certification number preceded
by “IC:” For example, if the certification number is “123 1234 A”, then the self-mark would read “IC: 123 1234 A”. (ii) For a new model that is registered to a family of previously certified TE, the self-marking format shall be:
Industry Canada This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Reglement Canadien sur le matériel brouilleur.
Multiple Listing This terminal device may be multiple listed to other distributors based upon the approval granted to the original certificate holder. In order to obtain a multiple listing certification, the following documentation must be presented to Industry Canada:
(a) The model number, Industry Canada certificate number and certification number of the approved
equipment; (b) A letter from the original certificate holder authorizing the Department to use information on file to
grant a multiple listing certification. The name/model number, certificate number and certification number for the subject equipment must be shown. The letter must also declare that the model to be multiple listed is identical in design and construction to the originally approved model; (c) A letter, from the proposed multiple listee, requesting the certification; (d) A Terminal Equipment Certification / Testing Application and Agreement form, completed by the
proposed multiple listee; (e) A drawing, sample or illustration of the product label; and (f) Payment in accordance with TRC-49 section on Multiple Listings.

Appendix B – Technical Specifications
Specifications
Your MT2834ZDX fax modem meets the following specifications: Model Numbers MT2834ZDX, MT2834ZDXb Data Rates (Modem) 33.6K and 31.2K (ZDXb only), 28.8, 26.4K, 24K, 19.2K, 16.8K, 14.4K, 12K, 9600, 7200, 4800, 2400, 1200 and 0-300 bps Data Rates (Fax) 14,400, 9600, 4800 and 2400 bps Data Format (Modem) Serial, Binary, Asynchronous Compatibility (Modem) ITU-T V.34, AT&T V.32terbo, ITU-T V.32bis, V.32, Bell 212A and 103/113, ITU-T V.22, V.22bis, V.42, V.42bis Compatibility (Fax) ITU-T Group 3, T.4, T.30, V.21, V.27ter, V.29, V.17, and EIA TR29.2 Error Correction ITU-T V.42 (LAP-M or MNP 2, 3 or 4) Data Compression ITU-T V.42bis (4:1 throughput) or MNP 5 (2:1 throughput) Speed Conversion Serial port data rates adjustable to 300, 1200, 2400, 4800, 9600, 19.2K, 38.4K, 57.6K and 115.2K bps Mode of Operation Half or full duplex over dial-up lines; automatic or manual dialing, automatic or manual answer Flow Control XON/XOFF, hardware (RTS/CTS), HP (ENQ/ACK) Intelligent Features Fully AT command compatible, autodial, redial, repeat dial, pulse or tone dial, dial pauses, call status display, auto parity and data rate selections, keyboard-controlled modem options, on-screen displays for modem option parameters, command lines of up to 60 digits each, and help menus Command Buffer 60 characters Modem Modulations FSK at 300 bps, PSK at 1200 bps, QAM at 2400, 4800, and 9600 bps (non-trellis), QAM with trellis coded modulation (TCM) at 9600, 12K, 14.4K, 16.8K, 19.2K, 21.6K, 24K, 26.4K, 28.8K, 31.2K and 33.6K bps Fax Modulations V.21 CH2 FSK at 300 bps, V.27ter DPSK at 2400 and 4800 bps, V.29 QAM at 7200 and 9600 bps, V.17TCM at 7200, 9600, 12K, and 14.4K bps Fax Carrier Frequencies V.21 Ch2 (half duplex): 1650 Hz mark, 1850 Hz space for transmit originate 1650 Hz mark, 1850 Hz space for transmit answer V.27ter: 1800 Hz originate/answer V.29 QAM: 1700 Hz originate/answer V.17 TCM 1800 Hz originate/answer Transmit Level -13 dBm Frequency Stability +/-0.01% Receiver Sensitivity -43dBm under worst case conditions AGC Dynamic Range 43 dB Interface Connectors EIA RS-232C/ITU-T V.24/V.28 DB25 RS-232C connector; two RJ-11 phone jacks, power jack Cables One 14-foot RJ-11 phone cable (USA); external power transformer and cord Note: Any cables connected to the computer should be shielded to reduce interference. Diagnostics Power-on self test, local analog loop, local digital loop, remote digital loop Indicators LEDs for Transmit Data, Receive Data, Carrier Detect, 28.8K bps, 14.4K bps, 9600 bps, Off Hook, Terminal Ready, Error Correction, Fax Speaker Command-controlled speaker for call progress monitoring Manual Control Power switch Environmental Temperature range 0o-50oC (32o - 120oF); humidity range 20-90% (non-condensing) Power Requirements 100-130V AC, 50/60 Hz, 0.1A/5W Dimensions 10.8 cm wide x 14.8 cm long x 2.9 cm high (4.25” x 5.8” x 1.15”)

Appendix C – Warranty and Service
Multi-Tech Systems, Inc., (hereafter “MTS”) warrants that its products will be free from defects in material or workmanship for a period of two, five, or ten years (depending on model) from date of purchase, or if proof of purchase is not provided, two, five, or ten years (depending on model) from date of shipment.
MTS MAKES NO OTHER WARRANTY, EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.
This warranty does not apply to any products which have been damaged by lightning storms, water, or power surges or which have been neglected, altered, abused, used for a purpose other than the one for which they were manufactured, repaired by Customer or any party without MTS’s written authorization, or used in any manner inconsistent with MTS’s instructions.
MTS’s entire obligation under this warranty shall be limited (at MTS’s option) to repair or replacement of any products which prove to be defective within the warranty period or, at MTS’s option, issuance of a refund of the purchase price. Defective products must be returned by Customer to MTS’s factory — transportation prepaid.
MTS WILL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES, AND UNDER NO CIRCUMSTANCES WILL ITS LIABILITY EXCEED THE PRICE FOR DEFECTIVE PRODUCTS.
In the event that service is required, products may be shipped, freight prepaid, to our Mounds View, Minnesota factory:
Multi-Tech Systems, Inc. 2205 Woodale Drive Mounds View, MN 55112 Attn: Repairs, Serial #
A Returned Materials Authorization (RMA) is not required. Return shipping charges (surface) will be paid by MTS to destinations in U.S. and Canada.
Please include, inside the shipping box, a description of the problem, a return shipping address (must have street address, not P.O. Box), your telephone number, and if the product is out of warranty, a check or purchase order for repair charges.
For out of warranty repair charges, go to www.multitech.com/DOCUMENTS/Company/warranty/
Extended two-year overnight replacement service agreements are available for selected products. Please call MTS customer service at (888) 288-5470 or visit our web site at www.multitech.com/PARTNERS/Programs/orc/ for details on rates and coverage’s.
Please direct your questions regarding technical matters, product configuration, verification that the product is defective, etc., to our Technical Support department at (800) 972-2439 or email support@multitech.com. Please direct your questions regarding repair expediting, receiving, shipping, billing, etc., to our Repair Accounting department at (800) 328-9717 or (763) 717-5631, or email mtsrepair@multitech.com.
Repairs for damages caused by lightning storms, water, power surges, incorrect installation, physical abuse, or user- caused damages are billed on a time-plus-materials basis.

Appendix C – Warranty and Service
Your original point of purchase Reseller may offer the quickest and most economical repair option for your Multi-Tech product. You may also contact any Multi-Tech sales office for information about the nearest distributor or other repair service for your Multi-Tech product. The Multi-Tech sales office directory is available at www.multitech.com/PARTNERS/Channels/offices/
In the event that factory service is required, products may be shipped, freight prepaid to our Mounds View, Minnesota factory. Recommended international shipment methods are via Federal Express, UPS or DHL courier services, or by airmail parcel post; shipments made by any other method will be refused. A Returned Materials Authorization (RMA) is required for products shipped from outside the U.S.A. and Canada. Please contact us for return authorization and shipping instructions on any International shipments to the U.S.A. Please include, inside the shipping box, a description of the problem, a return shipping address (must have street address, not P.O. Box), your telephone number, and if the product is out of warranty, a check drawn on a U.S. bank or your company’s purchase order for repair charges. Repaired units shall be shipped freight collect, unless other arrangements are made in advance.
Please direct your questions regarding technical matters, product configuration, verification that the product is defective, etc., to our Technical Support department nearest you or email support@multitech.com. When calling the U.S., please direct your questions regarding repair expediting, receiving, shipping, billing, etc., to our Repair Accounting department at +(763) 717-5631 in the U.S.A., or email mtsrepair@multitech.com.
Repairs for damages caused by lightning storms, water, power surges, incorrect installation, physical abuse, or user- caused damages are billed on a time-plus-materials basis.
International distributors should contact their MTS International sales representative for information about the repairs for their Multi-Tech product.
Please direct your questions regarding technical matters, product configuration, verification that the product is defective, etc., to our International Technical Support department at +(763)717-5863. When calling the U.S., please direct your questions regarding repair expediting, receiving, shipping, billing, etc., to our Repair Accounting department at +(763) 717-5631 in the U.S.A. or email mtsrepair@multitech.com.
Repairs for damages caused by lightning storms, water, power surges, incorrect installation, physical abuse, or user- caused damages are billed on a time-plus-materials basis.
SupplyNet, Inc., can supply you with replacement power supplies, cables and connectors for selected Multi-Tech products. You can place an order with SupplyNet via mail, phone, fax or the Internet at the following addresses: Mail: SupplyNet, Inc. 614 Corporate Way Valley Cottage, NY 10989 Phone: 800 826-0279 Fax: 914 267-2420 Email: info@thesupplynet.com Internet: http://www.thesupplynet.com Online Warranty Registration If you have access to the World Wide Web, you can register your Multi- Tech product online at the following URL: http://www.multitech.com/register/ About the Internet Multi-Tech maintains a World Wide Web site at: http://www.multitech.com

Appendix D – WEEE Statement
July, 2005 The WEEE directive places an obligation on EU-based manufacturers, distributors, retailers and importers to take-back electronics products at the end of their useful life. A sister Directive, ROHS (Restriction of Hazardous Substances) complements the WEEE Directive by banning the presence of specific hazardous substances in the products at the design phase. The WEEE Directive covers all Multi-Tech products imported into the EU as of August 13, 2005. EU-based manufacturers, distributors, retailers and importers are obliged to finance the costs of recovery from municipal collection points, reuse, and recycling of specified percentages per the WEEE requirements. Instructions for Disposal of WEEE by Users in the European Union The symbol shown below is on the product or on its packaging, which indicates that this product must not be disposed of with other waste. Instead, it is the user’s responsibility to dispose of their waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or where you purchased the product.