User Guide 88311551Revision B All rights reserved. This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech Systems, Inc. All rights reserved.
Copyright © 1999 by Multi-Tech Systems, Inc.
Multi-Tech Systems, Inc. makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc., to notify any person or organization of such revisions or changes.
Record of Revisions Revision Description A Manual released. Preliminary (beta) release 3/15/99. B Data for 4S/4U versions added (11/30/99)
Patents This product is covered by one or more of the following U.S. Patent Numbers: 5.301.274, 5.309.562, 5.355.365, 5.355.653, 5.452.289, 5.453.986. Other patents Pending.
Trademarks The Multi-Tech logo is a registered trademark of Multi-Tech Systems, Inc. NetWare is a registered trademark of Novell, Inc. Pentium is a registered trademark of Intel Corporation. SCO is a registered trademark of Santa Cruz Operation, Inc. UNIX is a registered trademark of X/Open Company, Ltd. Windows 95 and Windows NT are registered trademarks of Microsoft.
Multi-Tech Systems, Inc.
2205 Woodale Drive Mounds View, Minnesota 55112 (612) 785-3500 or (800) 328-9717
Fax (612) 785-9874 Tech Support (800) 972-2439 Internet Address: http://www.multitech.com



NetWare Connect (Novell) Driver Installation (2S/2U only) 61
Configuring Ports for NetWare Connect 61 Removing the Driver (Novell) 61 SCO Open Server 5 Driver Installation 62
MultiTech Installation Script 63 Activating Ports in SCO Open Server 5 65 Removing the Driver (SCO Open Server 5) 67 Linux Driver Installation 68 Warranty & Service 71 AT Commands and S-Registers
73 Troubleshooting
142 Regulatory Info 148 Index 154
models ISIHP-2S/2U and ISIHP-4S/4U, multiport hybrid ISDN cards that can be plugged into any PCI slot for applications that involve ISDN or modem calls over ISDN BRI lines. When the ISIHP is used with Remote Access Servers (RAS), remote users can call in using either modems or ISDN terminal adapters (TAs). For V.90 modem calls, a 56kbps download speed can be achieved without the expense of T1, E1, or ISDN PRI lines. This manual also describes the ISIHP- 4SD, a serial interface card equipped with four terminal adapters only (no analog modems are present). The ISIHP-4SD is otherwise like the ISIHP-4S/4U models. S-models use the ISDN S interface; U- models use the ISDN U interface.
The ISIHP-2S/2U contains two terminal adapters and four V.90/ K56flex modems. The ISIHP-2S/2U uses two ISDN BRI lines (each offering two B-channels) to connect to the telco and these connect to its two built-in terminal adapters. In addition to handling ISDN calls, each terminal adapter can detect analog modem and fax calls. When
Induction Welcome and Product Description
Introduction

analog calls are detected, they are automatically connected to one of the four V.90 modems on the ISIHP board. In this way, these hybrid cards can handle either ISDN calls or analog modem calls. Although the ISIHP-2S/2U contains four ISDN TA ports and four analog modem ports, only four ports can be active at any one time (because only four B-channels are present). See Figure 1-1.
The ISIHP-4S/4U works like the ISIHP-2S/2U but contains four terminal adapters and eight V.90/K56flex modems. The 4S and 4U models each accommodate four ISDN BRI lines. The configuration of modem and TA ports for the 4S and 4U models is shown in Figure 1- 2.
The ISIHP-4SD contains four terminal adapters only (the daughter card containing the eight modems is absent). Since it accommodates four ISDN BRI lines (each offering two B-channels), it supports eight independent digital data connections.
Each terminal adapter appears as two ports to the server PC using the ISIHP card.
ISIHP cards also support dial-out applications via their modems or terminal adapters.
The ISIHP-2S/2U card offers eight RAS ports using two Basic Rate Interface (BRI) ISDN lines; the ISIHP-4S/4U has 16 ports using four BRI ISDN lines. For the ISIHP-2S/2U, its eight ports allow a server to accept any combination of analog modem and digital ISDN calls, making a maximum of four simultaneous independent data connections. For the ISIHP-4S/4U, its sixteen ports allow a server to accept any combination of analog modem and digital ISDN calls, making a maximum of eight simultaneous independent data connections. This arrangement gives the user the flexibility to customize the settings of the terminal adapters and modems. The terminal adapters on the ISIHP-4SD can make eight simultaneous independent connections.
Introduction

TA
TA

From the perspective of the server PC, the ISIHP-2S/2U is an eight- port serial card with eight devices permanently attached to the serial ports (Figure 1-1). The first four ports are the two terminal adapters, each of which appear as two ports. The remaining four ports are the four central site modems. The following chart summarizes the correlation of ports and devices.
2S/2U Port # Device ISDN Line Number
1 TA 1 2 TA 1 3 TA 2 4 TA 2 5 Modem 1 6 Modem 1 7 Modem 2 8 Modem 2
From the perspective of the server PC, the ISIHP-4S/4U is an sixteen- port serial card with sixteen devices permanently attached to the serial ports (Figure 1-2). The first eight ports are the four terminal adapters, each of which appear as two ports. The remaining eight ports are the eight central site modems. The following chart summarizes the correlation of ports and devices. The ISIHP-4SD contains terminal adapters only; no modems are present.
Introduction

4S/4U Port # Device ISDN Line Number
1 TA 1 2 TA 1 3 TA 2 4 TA 2 5 TA 3 6 TA 3 7 TA 4 8 TA 4
This ISIHP Quick Start Guide contains installation instructions and technical support information. Because its written for audiences with basic PC skills, step-by-step instructions for such basic operations as logging in and file editing are not included.
First developed by companies such as IntelTM, AT&TTM and Digital Equipment CorporationTM, the Peripheral Component Interconnect (PCI) bus used by your ISIHP card provides high performance and is easy to use. Because PCI devices contain registers with the device information required for configuration, full auto configuration of PCI Local Bus add-in boards and components is supported. Performance factors include a bus data path of 64 bits, clock speeds of 66 MHz, and bandwidth of 264 Mbs.

Ports on the ISIHP card can be associated with different protocols, as follows:
Auto-Protocol. Modem or terminal adapter automatically negotiates with host to operate using the hosts current protocol.
Central Site Modem. Common designation for analog modems built into the ISIHP card. These are V.90 modems. For the ISIHP-2S/2U, the last four modems should be designated as Central-Site modems; for the ISIHP-4S/4U, the last eight modems should be designated as Central-Site modems. (See Port/Device table on previous page.)
MultiLink PPP async. This protocol allows the functional bundling together of three WAN ports so they function as a single high- bandwidth data pipeline using only one IP address. Bundling occurs on demand when the needed bandwidth exceeds that available on a single circuit.
PPP async. (Point-to Point Protocol, asynchronous) Protocol allowing computers a dial-up connection to the Internet. PPP includes error detection, data compression and other improvements over Serial Line Internet Protocol (SLIP) connections.
V.120. Terminal rate adaptation protocols. These apply to ISDN B- channels when using a V interface. This protocol includes V.110.
X.75. An international standard that allows X.25 packet-switched networks to communicate with each other. X.75 is a gateway protocol for interconnection of X.25 public networks.
Introduction

Introduction

Installation
Hardware Installation

This section describes how to install the ISIHP server card into the PCI bus on your personal computer, which involves
Opening your PC
Installing the card into the PC
Pentium-based PC or compatible with PCI bus architecture Microsoft Windows 95, Windows 98, Windows NT version 4.0, SCO
Open Server version 5.0, Novell NetWare, or Linux At least one floppy drive 800 blocks of hard disk space for UNIX, 100K bytes for Windows
NT, 34K bytes for Windows 95, 50K bytes for Novell
ISIHP card RJ-45 ISDN cords (2 for ISIHP-2S/2U; 4 for ISIHP-4S/4U) ISIHP Driver Disk set ISDN TA Configuration Wizard disk Quick Start Guide
User Guide (this online manual) on CD-ROM
Never install telephone wiring during a lightning storm.
Never install telephone jacks in wet locations unless the jacks are
specifically designed for wet locations.
Never touch uninsulated telephone wires or terminals unless the
telephone line has been disconnected at the network interface.
Use caution when installing or modifying telephone lines.
Avoid using a telephone (other than cordless type) during an
electrical storm. There may be a remote risk of electrical shock from lightning.
Hardware Installation

Do not use the telephone to report a gas leak in the vicinity of that
leak.
Ports that are connected to other apparatus are defined as SELV.
To ensure conformity to EN 41003, ensure that these ports are connected only to the same type on the other apparatus.
Hardware Installation

a
a
a
a
a
a
a
a
a
International a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
V.110 Daughter Card a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
Modem Card a
a
a
a
a
ISIHP-4S/4U a
a
Intelligent Serial Interface Hybrid (ISDN/POTS) Cards
(Side View)
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
V.110 Daughter Card Modem Card
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
a
V.110 Daughter Card
a
a
a
a
a
a
a
a
a
a
a
a
a
Hardware Installation

U Interface S Interface S/T Interface

The mounting brackets for the four ISIHP cards are similar, but the LEDs are labeled differently. Below, and on the next page, are graphics for each bracket along with descriptions of the LED indicators.
Flashes between OFF and RED to indicate that neither SPID for that ISDN line has been verified.
Flashes between RED and GREEN to indicate that one SPID is correct.
A solid GREEN display indicates that both SPIDs are correct.
Solid GREEN indicates normal operation.
Flashes between RED and GREEN to indicate that the device has been reset.

When lit, indicates active or voice connection on

B-channel 1.
When lit, indicates active or voice connection on
B-channel 2.
Hardware Installation · B1 LED Indicator


Indicates U interface status connection.
Controlled by NT-1, which converts S/T
interface (4-wire ISDN) to U interface (2-wire ISDN).
When U interface and S/T interface are NOT
active, LED remains off.
Flashes 8 times/second (8 Hz)U interface
is attempting to activate.
Flashes once/second (1 Hz)U interface is
active; S/T interface is not fully active.
Lit, not flashingBoth U and S/T interfaces
are active.
Lights when the ISIHP-2S/2U is turned on.
Flashes until SPIDs are verified with the
central office switch; then remains lit without flashing.
Indicates data link layer status.
Hardware Installation · P LED Indicator · D LED Indicator

Installation
Software/Driver Installation

Software/Driver Installation (Windows NT)
The following procedure describes how to install the ISIHP card in a system operating Microsoft Windows NT 3.51 or 4.0 for use with Remote Access Service (RAS) server and other communications/fax server type applications. These procedures refer to both 3.51 and 4.0.


Software/Driver Installation (Windows NT)




Software/Driver Installation (Windows NT)
A transient dialog box will appear while the setup program is
loaded from the diskette to the PC hard drive.



Software/Driver Installation (Windows NT)


After the last ISIHP card has been added, click Close.

Software/Driver Installation (Windows NT)


The ISIHP-2S/2U now is installed in Windows NT.
To install terminal adapters:

Software/Driver Installation (Windows NT)



Software/Driver Installation (Windows NT)



Software/Driver Installation (Windows NT)



Software/Driver Installation (Windows NT)


Software/Driver Installation (Windows NT)



Software/Driver Installation (Windows NT)



Software/Driver Installation (Windows NT)




Software/Driver Installation (Windows NT)

After re-booting, the ISI Cards icon appears in the Control Panel.

You are now ready to configure the terminal adapter. See the section,Configuring the Terminal Adapter, on page 49.
Unlike many modem products, the ISIHP has no DIP switch for I/O addresses and no jumper to determine the IRQ code. The input/output address and the interrupt request code (IRQ) for the ISIHP are assigned automatically during driver installation. During any subsequent re-cofiguring of your PC, you may need to know the assigned I/O address and IRQ code. To determine the I/O address and IRQ assigned to the ISIHP:
icon

Software/Driver Installation (Windows NT)
(for Windows NT) click on Start, Settings, Control Panel and select
the ISI Cards icon; or click on Start, Programs, Administrative Tools (Common), Windows NT Diagnostics, Resources;

(for Windows 95) click on Start, Settings, and Control Panel. From
the Control Panel, click on System icon and then the Device Manager tab. From there, click on the Computer icon at the top of the Device Manager window. The Computer Properties dialog box will appear. In the View Resources tab, click on either the Interrupt Request (IRQ) or Input/Output (I/O) radio buttons to view lists of both the IRQs and I/O memory addresses in use in the computer and what devices are currently using these resources.

Software/Driver Installation (Windows 95/98)
This section describes how to install the ISIHP in systems operating Microsoft Windows 95 or Windows 98 to use with a Remote Access Service (RAS) server and other communications/fax server type applications.


Software/Driver Installation (Windows 95)



Software/Driver Installation (Windows 95)
To remove the ISIHP card:
To remove the drivers:


Software/Driver Installation (Windows 98)



Software/Driver Installation (Windows 98)


Windows 98 will now detect and create COM ports (for ISIHP-
2S/2U/4SD, 8 ports are made; for ISIHP-4S/4U 16 ports are made).

Software/Driver Installation (Windows 98)

The MultiTech PCI ISI Card is located under Multi Port Adapter. Click Ports (COM & LPT) to view the ports. Click OK to close.
To remove the ISIHP card:

Software/Driver Installation (Windows 98)
To install terminal adapters:
If other modems have been installed, the Modems Properties dialog box will appear.


Software/Driver Installation (Windows 98)
Click Add and the Install New Modem dialog box will appear. Check the box marked Don't detect my modem; I will select it from a list. Then click Next.



Software/Driver Installation (Windows 98)



Software/Driver Installation (Windows 98)



Software/Driver Installation (Windows 98)



Software/Driver Installation (Windows 98)


Software/Driver Installation (Windows 95/98)



Software/Driver Installation (Windows 95/98)


Software/Driver Installation (Windows 95/98)


Now you are ready to configure the terminal adapters.

Software/Driver Installation (Windows 95/98)
North American users must configure the terminal adapter to match network switch type, the service profile identifier (SPID), and the directory number (DN). For international users, the terminal adapter ships already configured for NET3, which should work on most phone lines in Europe. However, you may want to customize settings, regardless of your location. (See Optional Settings on the following page.)
You can configure the terminal adapters with the ISDN TA Configuration utility, ConfigMenu, or with AT commands. Instructions for all three are provided in this section.
ISDN TA Configuration Utilityrecommended for computers with
Windows 95/98 and Windows NT.
ConfigMenurecommended for computers with DOS or Windows
3.x and a VT100/ANSI compatible terminal or data communication program that includes VT100/ANSI terminal emulation.
AT Commandsallow you to fine tune TA operation with AT
commands and S-registers. Enter these commands in your data communication programs terminal mode. AT commands are described in detail in the online manual.
Before you connect the ISIHP-2S/2U to your network terminator, you must configure it to match the following:
Network Switch Type
Select the network switch type your ISDN service uses at its local

Software/Driver Installation (Windows 95/98)
central office. You can set the TA to NET3, AT&T 5ESS, NT DMS- 100, or US National ISDN-1. If you don't know the switch type, get the information from the local phone company. AT command: !CO=
SPIDs and DNs
The TA must be configured with the Service Profile Identifier (SPID). The SPID, assigned by the local phone company, is for the specific BRI line where TA is attached. The SPID field is empty prior to configuration. AT command: AT!C6= and AT*!C6
The Directory Number (DN) is the phone number another user would call to contact this TA once it is attached to the ISDN. AT commands: AT!N1= and AT*!N1=
The terminal adapters ship already configured for NET3, which should work for most telephone lines in Europe. If you want to customize settings, refer to the Optional Settings below.
Data TEI
The Data TEI is the TEI (terminal endpoint identifier) assigned to the data channel. You can select Auto TEI, a fixed TEI, or Disable. A TEI is a number used by the central office switch to uniquely identify each device that is connected to the network. When it uses dynamic TEI assignments (Auto TEI), the central office switch assigns a TEI each time the TA connects to the network. However, the ISDN service provider may assign a fixed TEI at subscription time, in which case you must configure the TA with the fixed TEI number. You also can disable the channel, which may be useful when multiple TAs are attached to a network terminator bus. AT command: !D3=
Voice TEI
The Voice TEI is the TEI assigned to the voice channel. You have the same choices as for Data TEI: Auto TEI, fixed TEI number, or Disable. AT command: *!D3=

Persistent DTR Dialing
A high DTR (Data Terminal Ready) signal on the serial port indicates that your computer or terminal is ready to communicate with your TA. DTR normally goes high when a communication program starts or is ready to dial. Persistent DTR dialing enables the TA to automatically redial the number stored in memory location 0 whenever DTR is high, and the serial port does not have an active call. You can enable or disable this feature. AT command: $D
Auto Answer Data Calls Rings to Answer
Select Auto Answer if you want the TA to automatically answer all incoming data calls (option does not affect analog port). The Rings to Answer number (range: 1255) selects number of rings the TA waits before answering an incoming call. Default: 1 ring. AT command: S0=
Dialing Method
Select either the Enbloc or the Overlap dialing method for use when establishing a data call. Your ISDN provider determines the dialing method. The enbloc method is used for most ISDN dialing; however, you can select the overlap method if you are working with a private network. AT command: %A97=
Data Protocol
The data protocol, also known as the B-channel protocol and the rate adaptation protocol, is the language spoken over each 64 Kbps channel between two ISDN devices. The devices on both ends of the ISDN link must use identical protocols. AT command: !Z
V.120 Protocolprovides rates up to 64000 bps on each B channel.
PPP Protocolprovides rates up to 64 Kbps per channel.
V.110 Protocol a rate adaptation protocol that adapts the rates of
slower asynchronous terminals to the data rate of the ISDN B- channels. 9600 bps V.110 connections are supported by the ISIHP products for compatibility with digital calls originating from GSM networks.
Software/Driver Installation

X.75 Protocol The ISIHP uses layer 2 of the X.75 protocol as an
error correction protocol on the B-channel.
Stored Numbers
The TA can optionally store as many as 10 phone numbers, up to 20 characters each. AT command: &Z=
Dialing Stored Numbers
The TA can dial a number previously stored in directory number n using the &Zn=x command. AT command: e.g., DS3
Software/Driver Installation



Software/Driver Installation


The next dialog box specifies the TA that has been identified.

Software/Driver Installation


13.The SPID dialog box appears (North America only). Referring to
your network configuration notes, enter the appropriate informa- tion; then click Next.

Software/Driver Installation



Software/Driver Installation



Software/Driver Installation

The ConfigMenu configuration utility can be used as another means of configuring the TA. ConfigMenu is installed in the TAs as part of the firmware.
To use ConfigMenu: 1. Start a data communication program and select the COM port where the TA is connected.

Software/Driver Installation

Network Configuration Menuconfigures network parameters such as switch type, data and voice TEIs, and data and voice MSNs. When you finish, select Save Network Configuration to save your work.
Call Control Configuration Menuchanges how the TA originates and answers calls. Options include Auto Answer, Rings to Answer, Dialing Method, and Persistent DTR Dialing.
Data Protocol Menuchanges rate adaption protocol used by the TA.
Stored Numbers Menustores up to ten phone numbers ( maximum of 20 characters each). Stored number 0 is the phone number that will be dialed if persistent DTR dialing is enabled.
Port Control Configuration Menuconfigures TAs serial port, including how TA responds to control signals on the serial interface.
Help Menuprovides assistance in navigating through the TA menu system or viewing the ISIHPs firmware version numbers.
You can configure the terminal adapters using AT commands, just as you would configure an analog modem. Use this method if you prefer to work with AT commands or if you have a special requirement not addressed by either of the configuration utilities.
To configure the TAs with AT commands:
Software/Driver Installation

Software/Driver Installation

Multi-Tech Systems provides AIO drivers for the ISIHP-2S/2U, so it can function with Novell compatible asynchronous applications (e.g., NetWare Connect). The AIO driver is simply an NLM (NetWare Loadable Module) that runs on the file server. Drivers must be loaded on the file server where the board is installed. Drivers can be loaded from the file servers console prompt or incorporated for autoloading in the AUTOEXEC.NCF file.
To install the Multi-Tech AIO driver, copy the file AIOISIX.NLM to the system directory of the file server from a workstation on the network. To copy, you can use the following command:
To load the driver, go to the system or PC console (where the ISIHP- 2S/2U is installed) and enter the following at the prompt:
LOAD AIOISIX [port=W] [int=X] [name=Y] [note=Z]
To install the ISIHP scripts, copy aiomdms.mdc to f:\system\aio\directory. Click Yes to overwrite the existing aiomdms.mdc file.
To set up NetWare Connect ports, enter LOAD NWCCON at the NetWare console prompt. LOAD NWCCON opens the NetWare Connect Configuration Utility. Select the appropriate menu options (modem type, speed, flow control, etc.)
In Novell, remove file AIOISIX.NLM from the system directory and make the appropriate changes to the Autoexec.ncf file.
Software/Driver Installation · {2S/2U models only}

The installation utility provided by SCO is called custom. This section describes opening the utility and installing the driver. The instructions below should be used only on SCO Open Server 5 systems. When you have completed the steps below, go to Multi-Tech Installation Script, which immediately follows this section.
Examining media. Please wait
Extracting Files... Executing Multi-Tech Serial Card Driver Init Script...
(B) In versions 5.0.4 and 5.0.5, press ENTER twice, or tab down to install and press ENTER.
Type Y and press ENTER. A message appears and you can begin configuring your system with the MultiTech Installation Script.
Software/Driver Installation

The Multi-Tech Installation Script for SCO Open Server 5 systems requests information about how many boards you want to install, designations for communication ports and printer ports, and how many pseudo devices you want to create for Multi_View utility. Based on this information, the appropriate driver files will be installed and linked with your systems kernel.
You can install up to 4 ISA/PCI cards in a system. The PCI cards will be autodetected on bootup. Enter the number of ISA cards you want to install and configure on your system (0-4):
Select 0, which indicates that your computer has a PCI bus and can autodetect the ISI cards.
Multi_View is a utility which will allow you to have multiple sessions on terminals that have multiple pages of physical memory. In order for this utility to work with MultiTechs serial cards, pseudo devices have to be created in your /dev directory. These devices are system-wide resources.
Enter the number of pseudo-devices to be created for the use of Multi_View utility (1 - 256).
The Multi_View utility initializes the multiple-page capability of terminals with multiple pages of memory. The number specified here is the total number of devices (between 1 and 256) available to all Multi-Tech terminals and its the number of pseudo devices available to the Multi_View utility.
Specify 8 pseudo devices for each ISIHP-2S or -2U card installed; specify 16 for each ISIHP-4S or -4U card installed. For example, if the computer contains three ISIHP-4S cards, you would enter 48.
Software/Driver Installation

This script also creates the devices in your system to communicate with the ports of ISICOM. The default prefix for the tty ports is ttyl. The default prefix for the printer is prnl. Is this acceptable? (y/n/q).
For most users, its best to select y, which entails accepting the default values. Then proceed to step 4.
Details for use of non-default port/printer values. The /dev directory holds device-information files used by the kernel to access the hardware. When you add an ISI card, you must give the ISI ports unique names so they do not conflict with existing ports or with other devices known to your system. If a device name has already been assigned to an existing device and the operator assigns that name to a new device, then the existing device will be deleted when the ISI port using its name is created.
a. To use a non-default base name, type N and then enter a basename having less than five characters. The base name you select will be used for all ports on each card you install. ISI port designations will have this form: [basename prefix][board number][port letter].
basename: Length is one to four characters. board number: Values will be 1, 2, 3, or 4, depending on
how many ISI cards are installed in your computer. port letter: Use letters A through H.
In SCO UNIX, values A-H indicate modem ports.
b. After you select a device basename, you are prompted for a printer
base name. This prefix identifies each port that supports a terminal with a printer attached to its auxiliary port (for transparent printing). Specify a unique printer base name (printer parameters are outlined in the Multi_Setup Utility section in this manual ).
Software/Driver Installation

When you have specified the device base name and the printer base
name, press Enter to continue.
You have chosen the following setup The tty prefix is ttyl. The printer prefix is prnl. Number of Multi_View pseudo devices [user-specified number].
If these values are correct, type Y and the installation process will continue. If there is an error in any of the values displayed, type N and the first screen displays. Then re-enter the information for each card.
When you accept the confirmation list (by typing Y), a series of messages displays while the driver is being installed and the kernel rebuilt. After the terminals have been added to the Terminal Control database, and when the display says Press <Enter> to continue:, then press ENTER. When Installation complete displays, press ENTER again.
Type shutdown -g0-y and press ENTER
OR Type init 6 and press ENTER . Driver installation for the ISIHP card now is complete.
SCO Open Server 5 provides a device database that monitors the activity of serial ports through which users can log onto the host. If your ISI ports are used by terminals (e.g., to allow users to log onto your host), you must create an entry in the systems device database
Software/Driver Installation

that furnishes specific information for the terminals that will be used on each ISI port. The database is referenced each time a user attempts to log in. If there is no database entry for a particular terminal, access to the host is denied.
2. Type the complete name of the first device you want to create in usr/lib/uucp/Devices. Substitute the specific base name, board number, and port letter for the generic parameters in the expression ttylbx. Use a lower-case x value for local DTE (terminal) support and an upper case X value for modem control for each port you want to enable. Example: ttyl2A denotes the second ISI card (2) and the first port on that card (A). The port status can be altered later, but one setting must be selected at this time. The ACU line would read as follows: ACU ttylbX - 9600 dialer name. Replace b, X and dialer-name with appropriate values.
Software/Driver Installation

To remove the Multi-Tech Serial Card Driver, enter the configuration utility (e.g., custom for SCO Open Server 5) and follow instructions to remove the entire driver and rebuild the kernel without the ISI driver. If it is necessary to reinstall the driver due to I/O address or IRQ overlap, remove the driver first.
Software/Driver Installation

Or, you can include the configuration in the appropriate start-up script stored in the /etc/rc.d/ folder, so it loads when you start the computer.
insmod <destination folder>isicom.o ISIBase1=0xXXXX Irq1=XX ISIBase2=0xXXXX Irq2=XX Linux Driver Installation
ISIBasex and Irqx represent the base I/O address and IRQ that are
passed to the driver at module loading time. See the insmod manual page for more details on parameter passing.
Software/Driver Installation

Device files corresponding to ports on the ISIHP cards are created in the / dev folder. Use ttyMxy for normal ports and cumxy for corresponding callout ports. The letter x is the card number (14), and y is the port number, (ap) for 16-port cards.
Normal ports (ttyM) are configured for dial-in connections. Callout ports (cum) are used for dial-out connections.
To view busy I/O address space on your system, enter:
To view busy IRQs, enter:
To load the driver manually, use insmod.
Example: To load two ISI cards configured with base I/O addresses 0x210 and 0x200 and IRQs 5 and 10, enter the following in the destination folder:
insmod isicom ISIBase1=0x210 Irq1=5 ISIBase2=0x200 Irq2=10
To remove the driver manually, enter rmmod isicom. This removes the driver only if no ISI ports are in use.
Software/Driver Installation · cat /proc/ioports · cat /proc/interrupts

Software/Driver Installation

Warranty and Service Information
Information
You can access updated versions of firmware, drivers, flash utility programs and other software-related support for ISIHP server cards via the MultiTech web site and/or the MultiTech FTP site.
www.multitech.com (click Support; click Updates --Modem and ISI
Drivers; select operating system; then see Multiport Card PCI Bus)
ftp://ftp.multitech.com (see Directory ISI Cards)
Multi-Tech has an excellent technical support staff available to help you get the most out of your Multi-Tech product. If you have any questions about the operation of this product, call Technical Support at (612) 717-5863. Model and serial numbers are located on the Multi-Tech label on the component side of the ISIHP. To display the firmware version, type ATI1 in terminal mode. Software versions are printed on the diskette labels. Before calling Technical Support, note the status of your equipment, including screen messages, diagnostic test results, problems with a specific application, etc.

Warranty and Service Information
Multi-Tech Systems, Inc. (MTS) warrants that its products will be free from defects in material or workmanship for a period of two years from the date of purchase, or if proof of purchase is not provided, two years from date of shipment. MTS MAKES NO OTHER WARRANTY, EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. This warranty does not apply to any products which have been damaged by lightning storms, water, or power surges or which have been neglected, altered, abused, used for a purpose other than the one for which they were manufactured, repaired by the customer or any party without MTSs written authorization, or used in any manner inconsistent with MTSs instructions.
MTSs entire obligation under this warranty shall be limited (at MTSs option) to repair or replacement of any products which prove to be defective within the warranty period, or, at MTSs option, issuance of a refund of the purchase price. Defective products must be returned by Customer to MTSs factory transportation prepaid.
MTS WILL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES AND UNDER NO CIRCUMSTANCES WILL ITS LIABILITY EXCEED THE PURCHASE PRICE FOR DEFECTIVE PRODUCTS.

AT Commands and S-Registers
and
S-Registers
Contents Modem AT Commands 74 Modem S-Registers 94 Modem Result Codes 101 Terminal Adapter AT Commands 104 Terminal Adapter S-Registers 126 Terminal Adapter Result Codes 135 Using AT Commands to Operate the Terminal Adapter 136

Modem AT Commands & S-Registers
ISIHP modems are controlled by instructions called AT commands, so called because the attention characters, AT, precede each command or sequence of commands (known as a command string). You can send commands to the modem from your keyboard while in terminal mode, or you can use communications software to issue these commands automatically.
The modem is in command mode when it is not dialing or online. When it is in command mode, you have access to a complete communications system that allows you to use several features, including the basic AT command set described in this chapter. Using the basic AT command set, you can enter phone numbers for automatic dialing, configure modem options, and monitor telephone activity. In addition, you can command your modem to perform advanced features such as error correction, data compression, speed conversion, and more.
This chapter describes the modems operational modes and shows you how to use each modem AT commands. These commands and responses are compatible with all systems and with all data communications software using the AT command set.
The modem operates in two basic functional modes: command mode and online mode. (There is also an in-between state, wait-for-carrier, in which the modem is out of command mode but not yet online.) When you turn on the modem, it is in command mode and is ready to accept and respond to commands from your keyboard or software.
The modem enters online mode after it dials, connects with another modem, and detects a valid carrier signal. If it does not detect a carrier signal within the time frame controlled by the S-register S7, the modem abandons the call and reenters command mode.
You can make the modem enter online mode without dialing by entering AT and then D (dial) or A (force answer mode). The modem exits online mode if the carrier signal is lost or intentionally dropped. When this happens, the modem hangs up and reenters command mode. By sending certain escape characters to the modem while online, you can make it enter command

Modem AT Commands & S-Registers
mode without losing the carrier signal. While waiting to establish the carrier, you can type any character from the keyboard to make the modem to go back to the command mode.
You can control a wide variety of modem operations and options when the modem is in command mode. AT commands tell the modem to dial a number, to answer a call, to operate at a certain speed, to use a certain compression technique, and many other functions. AT commands consist of one or two letters, which may be preceded by an ampersand (&), a percent character (%), or a slash character (/). The Q command, for example, determines whether the modem returns result codes, while the &Q command selects the asynchronous communications mode.
A parameter after a command (0, 1, 2, etc.) tells the modem which option to use. If you do not specify a parameter, the modem assumes the 0 (zero) option. E, for example, is the same as E0. You can issue several commands on a single line (a command string) as long as the line does not exceed 40 characters.
Each command has a valid range of parameters. For example, &S can have only 0 or 1 as a parameter. Valid commands always generate an OK result code, and a few generate an additional response such as a list of parameters. An invalid command such as &S3, which has a parameter outside the valid range, generates an ERROR result code. Most commands have a default parameter that is enabled when the modem is turned on or reset with the ATZ or AT&F command. Factory defaults are stored in read-only memory (ROM) and cannot be changed. User-defined defaults can be stored in nonvolatile random-access memory (NVRAM) and can be changed or deleted at will.
Always begin a command with the letters AT. Enter the entire command string in upper or lower case, but do not mix cases within the command

Modem AT Commands & S-Registers
string. The AT command is not executed until you press ENTER. Use the BACKSPACE key to erase the previous command character. It will not erase the AT characters once they are typed. If your keyboard has no BACKSPACE key, use CTRL+H. (You can change the character recognized by the modem as BACKSPACE to any other ASCII character by changing register S5.)
Press CTRL+X to cancel an entire command that has been typed but not yet executed. This also clears the command buffer. The effect is the same as backspacing the command, only quicker.
The modem stores characters entered in a command in its command buffer until they are executed by pressing ENTER. The command buffers capacity is 40 characters. The attention characters (AT) do not count toward the 40- character command line maximum. You may use spaces for increased readability when typing a command. Spaces are not stored in the command buffer, and they do not count towards the 40-character command line maximum. Special characters, such as hyphens and parentheses, are not allowed.
If you exceed the 40-character limit or type invalid characters, the command buffer is automatically erased and an ERROR message appears. Retype the command within the 40-character limit, using only the allowed characters.
The commands in this chapter are organized by function. Abbreviated commands are listed on the next page by function along with a short description and page numbers that refer to a more detailed description, immediately following this list.
Topic Command Description Dialing Action, p. 79 D Dial
H On-hook/off-hook Dial Modifiers, p. 79 L, P, T, W Command accepted, but has no function , Command accepted, but has no function ; Command accepted, but has no function

Modem AT Commands & S-Registers
! $ @ ^ Command accepted, but has no function Phone Number Memory, p. 80 &Z Store a phone number
DS Dial a stored number Configuration Storage & Recall, p. 81
&W Store configuration &F Load factory default configuration Z Reset modem &Y Select stored con- figuration on power-up Modem Responses (Result Codes), p. 82 E Echo command mode characters Q Result codes: enable/ disable V Result codes: verbose/ terse \V Protocol result code X Result codes and call progress &Q Select asynchronous communications mode Online Connection, p. 84 B Answer tone C Carrier control F Echo online data characters &G Guard tones -C Data calling tone N Modulation handshake \T Disable inactivity timer Y Long space disconnect

Modem AT Commands & S-Registers
RS-232 Interface Controls, p. 86 &C Carrier Detect control &D Data Terminal Ready control &S Data Set Ready control
Error Correction & Data \N0 or &Q6 Non-error correction
mode Compression, p. 89 \N3 Auto-reliable mode \N2 Reliable mode %C0 Data compression disabled %C1 Data compression enabled Immediate Action, p. 89 A/ Repeat last command I Information request
&B V.32 auto retrain &V View current configuration Flow Control, p. 90 &M0 Asynchronous mode &K0 or \Q0 Flow control disabled &K3 or \Q3 Hardware flow control &K4 or \Q1 XON/XOFF flow control \X0 XON/XOFF no pass- through &J Auxiliary relay control \J Enable data buffer control \G Modem port flow control \K Set break control Escape Sequences, p. 92 +++AT<cr> Default in-band escape
sequence A Force answer mode

Modem AT Commands & S-Registers
O Go back online Dialing Commands
Use dialing commands to dial and hang up.
Ds Dial s = phone number Default: none
Causes the modem to dial the telephone number immediately following it. For example, if you type ATD5551212<cr>, the modem dials the number 555-1212.
Hn On-Hook/Off-Hook n = 0 or 1 Default: 0
Makes the modem hang up (go on-hook) or simulate the action of picking up a telephone handset (go off-hook).
H0 (or H) hangs up the modem
H1 brings the line off-hook, just as if you had picked up the telephone handset.
It is not necessary to use the H1 command to bring the line off-hook when using the D command. The modem automatically goes off-hook when you press ENTER at the end of the dial command.
ISIHP-2S/2U/4S/4U modems rely on the terminal adapters on the card for dialing. For backwards compatibility, the following dial modifier commands can be included in the dial string. They are accepted by the modem, but ignore the actual function. These commands are:
L Redial Last Number P, T Pulse or Tone Dialing W Wait for New Dial Tone , Dialing Pause ; Return to Command Mode After Dialing

Modem AT Commands & S-Registers
! Flash On-Hook $ Detect Call Card Tone @ Quiet Answer ^ Disable Data Calling Tone Transmission
ISIHP modems can store up to four telephone numbers in nonvolatile memory. You can store the numbers with the &Z command and dial them with the ATDS command.
&Zn=s Store a Phone Number s = phone number n= 0, 1, 2 or 3 Default: none
You can store a telephone number string in the modems phone number memory. You can store four of these strings using the &Zn=s command. The memory locations are labeled N0 through N3. For example, the telephone number 1-612-555-1212 is stored at memory location N2 by typing &Z2=16125551212 and pressing ENTER.
DSn Dial a Stored Number n = 0, 1, 2, or 3 Default: none
You can automatically dial a telephone number that is stored in the modems number memory by typing ATDSn, where n = 0 through 3. For example, you can dial a number stored at N2 by typing ATDS2 in terminal mode and pressing ENTER.
The ISIHP-2S/2U stores parameters in two places. It stores factory default parameters in read-only memory (ROM), and customized parameters in nonvolatile random access memory (NVRAM). You cannot change the default parameters in ROM, but you can change parameters in temporary memory and then store them in NVRAM as custom settings. You can then recall the custom settings as if they were factory default settings.

Modem AT Commands & S-Registers
&Wn Store Configuration n = 0 Default: &W0
The &W command stores current AT commands and S-register values in nonvolatile memory, so you wont lose your custom settings when you turn off the modem or reset it.
&W0 (or &W) stores all current AT command and S-register values in nonvolatile random access memory (NVRAM) and configures the modem so it reads your custom settings in NVRAM when the modem is turned on or when it is reset with the Z command. The &F reset command continues to read the factory default settings in ROM.
&Fn Load Default Configuration n = 0 Default: &F0
ISIHP-2S/2U modems store factory default AT command settings and S- register values in read-only memory (ROM); they store your custom AT command and S-register values in nonvolatile random access memory (NVRAM).
The &F0 (or &F) command resets modem to the factory default values stored in ROM.
Zn Reset Modem n = 0 or 1 Default: none
The Z command resets the modem to the configuration last saved by the &W command. The default values come from the customized configuration in NVRAM.
Z1 is the same as Z0, and functions identically.
&Yn Select Stored Configuration for Hard Reset n = 0 Default: 0
This command is included for compatibility with applications that issue the &Y0 command. Modem functions are not changed.

Modem AT Commands & S-Registers
&Y0 selects the profile stored at location 0 on power-up.
ISIHP modems can give responses to commands. The most common is OK, but the modems also can alert you or your software to dial tones, busy signals, connection speeds, and whether the connection is made with error correction or compression enabled. These responses are called result codes; they can be terse (numbers) or verbose (text).
En Echo Command Mode Characters n = 0 or 1 Default: E1
Normally, when you type commands on the keyboard, the modem echoes the characters back to the computer or terminal, which displays them on the monitor. Use the E command to turn this feature off and on.
E0 disables the echo.
E1 enables the echo.
Qn Result Codes Enable/Disable n = 0 or 1 Default: Q0
Use the Q command to enable or disable result codes for applications such as computer-controlled auto dialing.
Q0 (or Q) enables result codes.
Q1 disables result codes for applications such as computer-controlled auto- dialing.
Vn Result Codes (Verbose/Terse) n = 0 or 1 Default: V1
The V command controls whether the modems result codes display as text (verbose) or numeric (terse) messages. For example, if no carrier signal is detected after dialing, the result can display either as NO CARRIER or as the number 3.

Modem AT Commands & S-Registers
V0 (or V) displays the modems result codes as a number.
V1 displays result codes as text.
V2, an additional command given anytime after ATV1 is entered, displays the connect message of both the local modem and the remote modem.
Xn Result Codes and Call Progress Selection n = 0, 1, 2, 3, 4, 5, 6, or 7 Default: X4
Selects which result codes the modem provides in command mode and determines whether the modem uses smart dialing or blind dialing. When it smart dials, the modem listens for dial tones and busy signals and responds to them. When it blind dials, the modem ignores the signals and relies on timing instead.
X0 causes the modem to blind dial. Instead of looking for a dial tone, it pauses for the time set in register S6 and then dials regardless. Once a connection is made, it sends the basic code CONNECT to the terminal. It ignores any busy signals.
X1 causes the modem to blind dial. In addition to the basic CONNECT code, it provides extended codes consisting of the word CONNECT and the speed of the connection (CONNECT 14400 or CONNECT 28800, for example). In this mode, the modem does not recognize or respond to dial tones or busy signals.
X2 causes the modem to wait for a dial tone before dialing. If it does not detect a dial tone within the time set by S6, the modem sends a NO DIALTONE result code to the terminal. In this mode, the modem provides extended result codes but does not respond to busy signals.
X3 causes the modem to blind dial and to look for a busy signal. If it detects one, it sends a BUSY result code to the terminal. In this mode, the modem provides extended result codes, but it does not respond to dial tones.
X4 causes the modem to look for a dial tone and a busy signal and respond with NO DIALTONE or BUSY, as appropriate. It also provides extended result codes. It is the most useful setting for most data communication programs and is the default setting.
X5 causes the modem to look for a dial tone and a busy signal and respond

Modem AT Commands & S-Registers
with NO DIALTONE or BUSY, as appropriate. It also provides extended result codes. It is the most useful setting for most data communication programs and is the default setting.
X6 causes the modem to look for a dial tone and a busy signal and respond with NO DIALTONE or BUSY, as appropriate. It also provides extended result codes. It is the most useful setting for most data communication programs and is the default setting.
X7 causes the modem to wait for a dial tone before dialing. If it doesnt detect a dial tone within the time set by S6, the modem sends only the basic result code to the terminal (ERROR, NO CARRIER, or CONNECT, for example). In this mode, the modem does not respond to busy signals.
&Qn Asynchronous Communications Mode n = 0, 5, or 6 Default: &Q5
Allows you to select the type of asynchronous communications mode for your modem.
&Q0 selects asynchronous mode with data buffering. This is the same as \N0, nonerror correction mode with data buffering.
&Q5 selects error control with data buffering. This is the same as \N3, V.42/MNP auto-reliable mode.
&Q6 selects asynchronous mode with data buffering. This is the same as \N0, non-error correction mode with data buffering.
The following commands control the conditions of the online connection.
Bn Answer Tone n = 0, 1, 2, 3, 15, or 16 Default: B1 and B16
Selects the frequency the modem uses for its answer tone. (The answer tone is the tone transmitted by the receiving modem to the calling modem, thus

Modem AT Commands & S-Registers
initiating the handshake between the two modems.) At higher speeds (2400 bps and above) there is no conflict because all protocols use the Bell frequency of 2225 Hz. Lower speeds require different frequencies.
B0 selects ITU-T V.22 mode when the modem is at 1200 bps.
B1 selects Bell 212A when the modem is at 1200 bps. This is a default.
B15 selects V.21 when the modem is at 300 bps.
B16 selects Bell 103J when the modem is at 300 bps. This is a default.
Cn Dummy Command
-Cn Data Calling Tone n = 0 or 1 Default: -C0
The data calling tone is a tone of a certain frequency and cadence, as specified in the V.25 standards, which identifies whether it is remote data, fax, or voice. The frequency is 1300 Hz, with a cadence of .5 s on and 2 s off.
-C0 disables the V.25 data calling tone.
-C1 enables the V.25 data calling tone.
&Gn Guard Tones n = 0, 1, or 2 Default: &G0 (models outside U.K.) or &G2 (U.K. models only)
Controls the presence or absence of guard tones from the transmitter when in answer mode at either 1200 or 2400 bps. Guard tones are used in Europe and other areas to allow the modem to function in the telephone systems. Guard tones are not used in the United States. U.K. models are locked at &G2 (1800 Hz guard tone).
&G0 disables ITU-T guard tones.
&G1 enables ITU-T 550 Hz guard tone.
&G2 enables ITU-T 1800 Hz guard tone.
F Dummy command

Modem AT Commands & S-Registers
Nn Modulation Handshake n = 0 or 1 Default: N1
Controls whether the local modem performs a negotiated handshake with the remote modem at connection time when the communication speed of the two modems is different.
N0 enables handshaking only at the communication standard specified by S37 and the ATB command.
N1 always begins the handshake only at the communication standard specified by S37 and the ATB command, but allows fallback to a lower speed as the handshake proceeds. This is the default.
\Tn Inactivity Timer n = 0 Default: \T0
The inactivity timer specifies the length of time, in minutes, that the modem waits before disconnecting when no data is sent or received. This timer is specified in register S30. The \T0 command disables the inactivity timer.
Yn Long Space Disconnect n = 0, 1 Default: Y0
When two modems are connected in reliable mode, a link disconnect request packet is sent to request a disconnect. In non-error correction mode, there is no polite way to request a disconnect. As a result, some garbage may be received when a hang-up command is issued.
Y0 disables the modems use of the break signal.
Y1 enables long space disconnect.
These commands define how the ISIHP-2S/2U modems use and respond to standard RS-232 signals.
&Cn Carrier Detect Control n = 0 or 1

Modem AT Commands & S-Registers
Allows you to control the Carrier Detect (CD) signal on the RS-232/V.24 interface. This is a signal from the modem to your computer indicating that the carrier signal is being received from a remote modem. Normally, CD goes high (turns on) when the modem detects a carrier on the communications link and drops (turns off) when it loses the carrier. By using &C, you can force the signal to stay high, or to drop momentarily when the remote modem disconnects. This option is useful with some CBX phone systems and mainframe front ends, which require CD to act in this manner.)
&C0 ignores the state of the carrier from the remote modem. CD is forced high.
&C1 allows CD to act normallyto go high when the modem detects a carrier, and to drop when it loses the carrier.
&Dn Data Terminal Ready Control n = 0, 1, 2, or 3 Default: &D2
The Data Terminal Ready (DTR) signal on pin 20 of the RS-232/V.24 interface must be high, or on, in order for the modem to operate. A high DTR signal tells the modem that the computer it is connected to is ready to communicate through the modem.
The DTR signal can also be used to cause the modem to reset to its default parameters, as if you had given the modem an ATZ command.
&D0 (or &D) causes the modem to ignore the DTR signal and treat it as always on.
&D1 causes the modem, if in online data mode, to enter command mode, issue an OK and remain connected when the DTR drops.
&D2 causes the modem to hang up when DTR drops while the modem is in online data mode.
&D3 causes the modem to reset when DTR drops . It will also hang up if it is online.

Modem AT Commands & S-Registers
&Sn Data Set Ready Control n = 0 or 1 Default: &S0
Controls the state of the Data Set Ready (DSR) signal on the RS-232/V.24 interface. Normally, DSR follows CD. You can force the signal high or allow it to act normally.
&S0 forces DSR high (on).
&S1 allows DSR to act normally, that is, to follow CD.
You can configure modems to any of three different V.42 modes of operation (with or without compression): non-error correction, auto- reliable, and reliable modes. You also can turn data compression on or off.
\Nn Error Correction Modes n = 0, 1, 2, 3, 4, 5, or 7 Default: \N3
Select the modems error correction mode using the \N command.
\N0 disables the modems V.42 error correction capabilities, and the modem functions as a non-error correction modem with data buffering. This is the same as &Q6, described earlier in this chapter.
\N1 causes the modem to function in direct mode.
\N2 enables reliable mode, in which the modem uses its V.42 error correction capabilities for all transmissions. In reliable mode, the modem must be connected to a modem with the V.42 MNP protocol.
\N3 enables auto-reliable mode. During the handshaking procedures at the start of the online connection, the modem queries whether the other modem is using V.42 error correction. If the modem determines that the other modem is using V.42, it switches itself into reliable (V.42) mode and enables error correction. If it determines that the other modem is not using V.42, the modem remains in non-error correction mode. (This is the same as \N5 and \N7.)
\N4 enables reliable mode, in which the modem uses its V.42 error correction capabilities for all transmissions. In reliable mode, the modem

Modem AT Commands & S-Registers
must be connected to a modem with a V.42 protocol (MNP or LAP-M).
The V.42 standard includes MNP Class 3 and 4 and LAP-M error correction methods.
\N5 enables auto-reliable mode. During the handshaking procedures at the start of the online connection, the modem queries whether the other modem is using V.42 error correction. If the modem determines that the other modem is using V.42, it switches itself into reliable (V.42) mode and enables error correction. If it determines that the other modem is not using V.42, the modem remains in non-error correction mode. (This is the same as \N3 and \N7.)
\N7 enables auto-reliable mode. During the handshaking procedures at the start of the online connection, the modem queries whether the other modem is using V.42 error correction. If the modem determines that the other modem is using V.42, it switches itself into reliable (V.42) mode and enables error correction. If it determines that the other modem is not using V.42, the modem remains in non-error correction mode. (This is the same as \N3 and \N5.)
%Cn Data Compression n = 0 or 1 Default: %C1
The %C command allows you to disable data compression. Data compression is normally enabled.
%C0 disables V.42bis/MNP 5 data compression.
%C1 enables V.42bis/MNP 5 data compression.
Use immediate action commands to obtain information about AT commands and current modem settings.
Type A/ to repeat the previous command. Do not precede this command with AT or press ENTER to execute it.
In Information Request

Modem AT Commands & S-Registers
This command displays specific product information about your modem.
I0 or I returns the controller firmware version number. Use this command to identify your modems firmware level before calling Multi-Tech Technical Support. (Same as I3.)
&Bn Dummy command
Use the &V command to display the active modem settings.
Flow control refers to techniques used by data terminal equipment and the modem to pause and resume the flow of information between them. It prevents a device from accepting more data than it can handle. The modem implements flow control in both directions. When the modem halts the flow of data, it is called flow control. When the computer halts the flow, it is called pacing.
&Kn Local Flow Control Selection n = 0, 3, or 4 Default: &K3
Allows you disable flow control and enable hardware or software flow control.
&K0 completely disables data flow control initiated by the modem. (Same as \Q0.)
&K3 enables modems use of Clear to Send (CTS) signal on the RS-232/ V.24 interface to regulate data flow. When CTS drops, data flow is suspended until the signal goes high (on) again. This method of flow control works in conjunction with pacing (i.e., computer-initiated flow control), which uses the Request to Send (RTS) signal on the RS-232/V.24 interface. Hardware flow control cannot be enabled unless an active error correction protocol is selected. This is the factory default setting. (This is the same as \Q3.)

Modem AT Commands & S-Registers
&K4 enables XON/XOFF software flow control. XON/XOFF flow control is an in-band method of data flow regulation. In-band data regulation means that the XON (^Q) and XOFF (^S) characters are inserted into the stream of data rather than using separate control lines. When an XOFF character is detected, the data stream is suspended until an XON character is detected. If you issue the &K4 command to the modem, it will respond to XON/XOFF pacing, and use XON/XOFF characters as its own method of flow control to the computer. (This is the same as \Q1.)
The drawback to using this method of pacing is that some files may contain these characters as part of the file data. If such a file is transferred using a modem with XON/XOFF flow control enabled, the file transfer could fail due to indefinite suspension.
\Qn Local Flow Control Selection n = 0, 1, or 3 Default: \Q3
Allows you disable flow control and enable hardware or software flow control.
\Q0 completely disables data flow control initiated by the modem. (This is the same as &K0.)
\Q1 enables XON/XOFF software flow control. XON/XOFF flow control is an in-band method of data flow regulation. In-band data regulation means that the XON (^Q) and XOFF (^S) characters are inserted into the stream of data rather than using separate control lines. When an XOFF character is detected, the data stream is suspended until an XON character is detected. If you issue the &K4 command to the modem, it will respond to XON/XOFF pacing, and use XON/XOFF characters as its own method of flow control to the computer. (This is the same as &K4.)
The drawback to using this method of pacing is that some files may contain these characters as part of the file data. If such a file is transferred using a modem with XON/XOFF flow control enabled, the file transfer could fail due to indefinite suspension.
\Q3 enables modems use of Clear to Send (CTS) signal on the RS-232/ V.24 interface to regulate data flow. When CTS drops, data flow is suspended until the signal goes high (on) again. This method of flow control works in conjunction with pacing (i.e., computer-initiated flow control),

Modem AT Commands & S-Registers
which uses the Request to Send (RTS) signal on the RS-232/V.24 interface. Hardware flow control cannot be enabled unless an active error correction protocol is selected. This is the factory default setting. (This is the same as &K3.)
\Xn XON/XOFF Pass-Through n = 0, 1 Default: \X0
When XON/XOFF pacing is active, the local modem has two options regarding the XON and XOFF characters. It can respond to and discard the characters from the computer, or it can respond to the characters and pass them through the data communications link to the remote modem, thereby pacing the remote modem as well.
\X0 causes the modem to respond to and discard the XON and XOFF characters (default)
\X1 causes the modem to respond to and pass on the XON and XOFF characters
\Jn Data Buffer Control n = 0 Default: \J0
\J0 disables force line rate less than or equal to DTE rate
\J1 enables force line rate less than or equal to DTE rate
\Kn Set Break Control n = 0, 1, 2, 3, 4, 5 Default: \K5
Determines how the modem processes a break signal received from the local DTE during an online connection.
\K5 causes the modem to send the break to the remote modem in sequence with transmitted data, non-destructive, non-expedited.
Escape sequences are also known as escape codes. They are used to cause

Modem AT Commands & S-Registers
the modem to enter command mode from online mode without disconnecting the call.
+++AT<cr> In-Band Escape Sequence If the modem is online with a remote modem, you can cause the modem to enter command mode without disconnecting the call by typing an escape code. The default escape code used by the modem is three plus signs (+++) followed by the letters AT, up to 10 command characters (most typically H, to hang up), and ENTER. The modem then escapes to command mode, executes the command (if any), and remains in command mode. For example, to hang up the modem at the end of a call, type +++ATH <cr>.
A Force Answer Mode You can use the A command to force the modem into answer mode. Type ATA when in command mode to immediately bring your modem off-hook, out of command mode, into online answer mode, and to cause it to transmit its carrier signal over the phone line. If no responding carrier tone is received by your modem within 45 seconds (or by the time you specified in register S7), your modem stops transmitting its tone, hangs up, and goes back into command mode.
On Go Back Online n = 0, 1, or 3 Default: none
Use the O command to bring the modem out of command mode and back into online mode. The O command reverses the result of entering the escape code. The O command brings modem into the online mode (originate or answer) it was in prior to entering command mode.
O0 causes the modem to exit command mode and return to online data mode.
O1 causes the modem to issue a retrain before returning to online data mode.
O3 causes the modem to issue a rate renegotiation before returning to online data mode.

Modem AT Commands & S-Registers
S-registers are small regions of memory where modem configuration information is stored. Whereas AT commands tell a modem what to do, S- registers tell the modem how to do it. Each S-register has a name that consists of the letter S and a number (S0, S1, S2, etc.), hence the term S- register. Use the Sr? command to read the value stored in an S-register and
the Sr=n command to change it.
S0 Number of Rings Until Modem Answers Unit: 1 ring Range: 0255 Default: 0
Defines number of rings the modem waits before answering an incoming call. Default value is zero, which effectively disables the auto-answer function. When auto-answer is disabled, the modem can only answer via the ATA command. Set the S0 register value to one to cause the modem to answer the call immediately after the first ring. Maximum number of rings that can be configured is 255.
Counts number of rings that have occurred. It is a read type of register and is seldom used in typical operation. Each time an incoming ring signal is detected, S1 increases its value by one, up to a maximum of 255. If you set S1 to a value other than its default value of zero, or if the value is increasing with rings, this new value remains stored in S1 for eight seconds after the last ring is counted, after which the value reverts back to zero.
Defines escape code character by its decimal ASCII code. Default character is the plus (+) sign (decimal 43). S2 can be set for any ASCII character.

Modem AT Commands & S-Registers
Setting an S2 value greater than 127 results in no escape character, resulting in no means of entering command mode from online mode without breaking the online connection unless you use the BREAK method.
Defines carriage return character by its decimal ASCII code. Default setting is the ^M character (decimal 13), the code for ENTER on most keyboards. Can be set for any ASCII character.
Defines the line feed character by its decimal ASCII code. Default setting is ^J (decimal 10), the code for the line feed key on most keyboards that have such a key. Can be set for any ASCII character.
Defines backspace character by its decimal ASCII code. Default setting is the ^H character (decimal 8), the code for BACKSPACE on most keyboards. Can be set for any ASCII character. Setting S2 to a value greater than 32 disables the backspace character.

Modem AT Commands & S-Registers
S6 Wait Time for Dial Tone Unit: 1 second Range: 265 (North America), 4255 (International), 47
Defines length of time the modem waits after ENTER is pressed before carrying out a dial command. Default setting is two seconds for North America, four seconds elsewhere.
S7 Time to Wait for Carrier Unit: 1 second Range: 1255 (USA), 145 (Canada and International),
Determines amount of time the modem waits for a carrier signal before it disconnects. Default value is 50 seconds except the UK model, which defaults to 55 seconds. After dialing, the modem waits for a carrier signal for up to 50 or 55 seconds and if none is detected, terminates the call. Maximum S7 value is 255 seconds for the US model, 45 seconds for Canadian and International models, and 55 seconds for the UK model. S7 also determines the wait for silence time for the @ dial modifier.
S8 Pause Time for Comma Unit: 1 second Range: 065 (North America), 4255 (International), 47
Determines the length of pause caused by a comma character in a dialing command. Default setting is two seconds for North American model and four seconds for international and UK models. S8 can be set for up to 65 seconds. S8 also defines the length of time the modem waits before retrying a call after it detects a busy signal. Some computer systems need more than two seconds to reset. If this is the case, increase the value of S8.

Modem AT Commands & S-Registers
S10 Carrier Loss Disconnect Delay Time Unit: 100 ms Range: 1254 Default: 20
Defines the length of time, in milliseconds, that the modem waits after a loss of carrier signal before the it disconnects. The default setting is 2000 ms (20 units of 100 ms each). Maximum delay is 25400 milliseconds, or 25.4 seconds (decimal 254).
S11 Tone Dialing Spacing and Duration Unit: 1 ms Range: 50 - 150 (US) or 80255 (Canada, UK,
Sets the speed of tone dialing (spacing and tone duration times). The default value is 95 units for domestic models and 80 units for Canadian and International models, where each unit is one ms. In other words, for domestic modems, each tone is sustained for 95 ms followed by a 95 ms pause. The minimum S11 value allowed is 50 ms (50 units). The maximum S11 value is 150 ms (150 units).
S28 Enable / Disable V.34 Modulation Unit: decimal Range: 0, 1255 Default:1 (enabled)
Enables or disables V.34 modulation. Setting S28 to zero (0) disables V.34 modulation. Any other setting (1-255) enables V.34 modulation.
Enables or disables the V.25 data calling tone, which allows remote data, fax and voice discrimination. Setting S35 to zero (0) disables V.25 data calling tone; setting S35 to 1 enables data calling tone. The default setting is 1.

Modem AT Commands & S-Registers
S37 Maximum Dial Line Rate Unit: decimal Range: 019 Default: 0
Sets the maximum dial line rate. When set to zero (0), the maximum dial line rate is the same as the maximum modem speed. This is the most common setting and allows other modem functions to actually determine the line rate used for each connection. It is the default. Consider using S37 to set a maximum dial line rate if you need to artificially retain a lower modem speed.
0 = maximum modem speed 13 = 19200 bps
1 = reserved 14= 21600 bps
2 = 1200/75 bps 15 = 2400 bps
3 = 300 bps 16 = 26400 bps
4 = reserved 17 = 28800 bps
5 = 1200 bps 18 = 31200 bps 6 = 2400 bps 19 = 33600 bps 7 = 4800 bps 8 = 7200 bps 9 = 9600 bps 10 = 12000 bps 11 = 14400 bps 12 = 16800 bps
S42 Enable / Disable Auto Rate Unit: decimal Range: 0-1 Default: 1 (enabled)
Enables and disables the 56K auto rate. Retrain and fallback are disabled in data mode. Set S42 to zero (0) to disable auto rate, or 1 (the default) to enable auto rate.
S43 Enable / Disable V.32bis Start-up Auto Mode Unit: decimal

Modem AT Commands & S-Registers
Used for testing and debugging only. Enables and disables V.32bis start-up auto mode operation. Set S43 to zero (0) to disable start-up auto mode, or 1 (the default) to enable start-up auto mode.
Sets the length of time, in seconds, a modem waits in the off-line command mode before it goes into standby mode. If S89 is set to 20 seconds, the modem waits 20 seconds in off-line command mode before going into standby mode. Setting S89 to zero (0) prevents the modem from ever entering standby mode.
Setting S89 to any value between zero and five (1-4) effectively sets the value to five, because five seconds is the minimum possible wait time.
Controls the line coding used by the modem.
S108 = 0 mu-law S108 = 1 A-law (default)
Controls the PCM ( pulse code modulation) mode (V.90 or K56Flex). Determines which mode the modem will answer in for PCM connections.
S109 = 0 K56Flex support only S109 = 1 Both V.90 and K56Flex supported S109 = 2 V.90 support only

Modem AT Commands & S-Registers
Use the S command to assign a value to an S-register and to read an its current value. To read an S-register value, in terminal mode, type S, the S- register number, and a question mark (?), and press ENTER. For example, to display the value of register S7, type ATS7? and press ENTER. The value appears as a three-digit decimal number (e.g., 045).
To assign a new value to an S-register, type S, the S-register number, an equals sign (=), and a decimal number. Convert all ASCII characters to their decimal equivalents before entering. Valid S-register decimal values are shown for each register in the previous section. To make the change permanent, use the &W0 command.
3. You are calling long distance to another country code, and it is taking a long time to connect. The register S7 (time to wait for carrier) factory default setting of 50 seconds is insufficient; a time- out occurs and cancels the call before a connection is made. To change the S7 value to 75 seconds, type ATS7=75 and press ENTER . Now, after dialing, the modem allows 25 more seconds for a carrier signal before aborting the call. The additional 25 seconds should provide enough time for international calls.

Modem AT Commands & S-Registers
verification read command in the same command string as the configuration assignment command. In the three preceding examples, type ATS8=5S8?, ATS0=4S3?, and ATS7=75S7?, respectively.
For maximum throughput, the ISIHPs default configuration is for originating a call to another 33,600 bps modem that supports error correction, data compression, and flow control. If the receiving modem is not compatible, the ISIHP can match any ITU-T or Bell standard modem (but not proprietary protocols).
If you require a different configuration for your applicationfor example, if you want to use an ISIHP modem strictly as an auto answering device or for service that does not support error correctionyou can change the command parameters and S-register values in active memory and save the new values with the &W command.
The &W0 (or &W) command stores all current AT command and S-register values into nonvolatile random access memory (NVRAM) and configures the modem so that it reads your custom settings in NVRAM when the modem is turned on or when it is reset with the Z command. (The &F reset command will continue to read the factory default settings in read-only memory [ROM].) For convenience, you can include the &W command in the same command string that sets the new values in active memory as in the following example: AT\N2&C1S0=10&W0 Modem Result Codes
0 OK Command executed without error; ready for next command.
1 CONNECT Modem has detected carrier and gone online.
2 RING Modem has detected ring caused by incoming call.
3 NO CARRIER No carrier signal has been detected within the allowed time.
Terse Verbose Definition

Modem AT Commands & S-Registers
4 ERROR Error in command line (too many, or invalid characters).
5 CONNECT 1200 Modem detected carrier at 1200 bps and gone online.
6 NO DIALTONE No dial tone detected.
7 BUSY Busy signal detected.
8 NO ANSWER The remote system did not answer.
10 CONNECT 2400 Modem detected carrier at 2400 bps and gone online.
11 CONNECT 4800 Modem detected carrier at 4800 bps and gone online.
12 CONNECT 9600 Modem detected carrier at 9600 bps and gone online.
13 CONNECT 14400 Modem detected carrier at 14400 bps
and gone online.
14 CONNECT 19200 Modem detected carrier at 19200 bps
and gone online.
24 CONNECT 7200 Modem detected carrier at 7200 bps and gone online.
25 CONNECT 12000 Modem detected carrier at 12000 bps
and gone online.
86 CONNECT 16800 Modem detected carrier at 16800 bps and gone online.
40 CONNECT 300 Modem detected carrier at 300 bps and gone online.
55 CONNECT 21600 Modem detected carrier at 21600 bps and gone online.
56 CONNECT 24000 Modem detected carrier at 24000 bps and gone online.
57 CONNECT 26400 Modem detected carrier at 26400 bps and gone online.

Modem AT Commands & S-Registers
58 CONNECT 28800 Modem detected carrier at 28800 bps and gone online.
59 CONNECT 31200 Modem detected carrier at 31200 bps and gone online.
60 CONNECT 33600 Modem detected carrier at 33600 bps and gone online.
CONNECT 45000 Modem detected carrier at 45000 bps and gone online.
CONNECT 56000 Modem detected carrier at 56000 bps and gone online.
88 DELAYED Delay is in effect for the dialed number.
89 BLACKLISTED The dialed number is blacklisted.
90 BLACKLIST FULL The blacklist is full.
Extended Result Codes. If the extended result codes configuration option is enabled, EC is added to the following result codes:
10 CONNECT 2400
11 CONNECT 4800
12 CONNECT 9600
13 CONNECT 14400
14 CONNECT 19200
24 CONNECT 7200
25 CONNECT 12000
86 CONNECT 16800
40 CONNECT 300
55 CONNECT 21600
56 CONNECT 24000

AT Commands and S-Registers
58 CONNECT 28800
59 CONNECT 31200
60 CONNECT 33600
CONNECT 45000
CONNECT 56000
EC is replaced by one of the following codes, depending on the type of error control connection:
V42bis LAP-M V.42 error control and V.42bis data compression V42 LAP-M V.42 error control only MNP5 MNP4 error control and MNP 5 data compression MNP4 MNP 4 error control only NoEC No error control protocol Terminal Adapter AT Commands
One of the ways you can communicate with and configure your terminal adapter (TA) is to use AT commands. AT commands are so-called because, with only a few exceptions, each command string begins with the characters AT. Using AT commands, you can read and set parameters and perform actions such as dialing.
Entering AT Commands You can send AT commands to the TA by typing them on the keyboard, by typing them in the terminal window of a data communications program such as HyperTerminal, or indirectly by configuring your data communications program.
Enter AT commands in the following format: AT <command string> <cr>. The AT characters cause the TA to interpret the following string of characters as a command. The command string consists of one or more commands. The carriage return character, , sends the command string to the TA. If you are entering a command string in your communication programs terminal window, insert the carriage return character by pressing
Code Error Correction

Terminal Adapter AT Commands & S-Registers
ENTER. On the other hand, if you are configuring a communications program, you typically must insert the carriage return character by adding ^M to the end of the command string.
The TA has three modes of operation: offline command mode (the default state), online command mode, and data mode. The TA responds to AT commands only when it is in one of the command modes. After the TA establishes a connection and goes online in data mode, it interprets any further characters you enter as data rather than commands and transmits them to the remote device.
When the TA is in data mode, you can switch it to online command mode by sending it an escape sequence. The TA responds to two types of escape sequences: in-band (escape sequence is part of the data stream) and out-of- band (escape sequence is outside the data stream). The in-band escape sequence is +++AT<cr>; the out-of-band escape sequence is <break >AT<cr>. You can change the in-band escape character (+) by changing the value in register S2. You can send the break signal in the out-of-band escape sequence only from software, not by pressing SHIFT+BREAK on your keyboard.
When it detects the escape sequence, the TA enters online command mode, in which it responds to commands while maintaining the connection with the remote device.
The TA s command buffer can store 80 characters, including spaces and other characters used in telephone numbers. If you mistype a command string, you can edit it by using the backspace key, but only before you press ENTER. As you type a command string, it appears on your monitor screen, letting you verify your input as you type it.
AT commands recognized by the ISIHP terminal adapter are listed by function on the following page. For an alphabetic list of AT commands, see AT commands in the index. The commands in this chapter are organized by function. Abbreviated commands are listed on the following page by function along with a short description and page numbers that refer to a more detailed description, immediately following this list.
Topic Command Description Command Implementation, p. 107AT Attention code Return Command execution

Terminal Adapter AT Commands & S-Registers
+++AT<cr> In-band escape code <break>AT<cr> Out-of-band escape code Switch Configuration, p. 108 %A97 Dialing method !C0 Switch type !C6 SPID 1 *!C6 SPID 2 !D3 SAPI-0 data TEI *!D3 SAPI-0 voice TEI !L List DN, SPID, TEI, Data
protocol & switch type >Dn Embedded Protocol Analyzer !N1, !N2, !DN1, !DN2, !EN1, !EN2 Data DN/MSN *!N1, *!N2, *!DN1, *!DN2, *!EN1, *!EN2 Modem DN/MSN !Z=n Rate adaptation protocol Serial Port Configuration, p. 114 En Command mode echo L List telephone numbers L5 List current operating parameters L6 List S-register values L8 Display low level ISDN status Qn Status displays Sr=n Set S-register Sr? Read S-register Vn Terse/verbose result codes Xn Connect messages Z Restore parameters to current power-up profile &Cn DCD (Data Carrier Detect) control

Terminal Adapter AT Commands & S-Registers
&Dn DTR (Data Terminal Ready) control &En Flow control #Xn Send Single Multiple Xoff Characters &Fn Load quick setup factory profile &Rn CTS (Clear To Send) control &Sn DSR (Data Set Ready) control &V View port configuration &Wn Store active profile &Zn= Store telephone number DSn Dial a Stored telephone number $Dn Persistent DTR dialing %En Escape sequence options @P3= Parity @P4= Data bits @P6= Stop bits $MBn V.110 Network Rate Data Call Commands, p. 124 A Answer D Dial
H Hang up In Display product information O Return online @Config Start ConfigMenu

Terminal Adapter AT Commands & S-Registers
AT precedes all command strings except the A/ command and escape codes.
Press the RETURN (ENTER) key to carry out a command. The RETURN key is sometimes abbreviated in command examples.
Sets the TA to enter command mode without disconnecting the call when it is online with a remote device. The default escape code is three + characters, followed by AT, up to 80 command characters, and a RETURN (press ENTER). The TA escapes to command mode, executes any commands in the string, and then remains in command mode. Use the S2= z command to change the escape character.
<break>AT<cr> Out-of-Band Escape Code
Places the TA in command mode while remaining online. Enter a break signal, the letters AT, up to 80 command characters, and a RETURN (press ENTER).
Use the following commands to select your network switch type (e.g., Northern Telecom DMS-100) and to specify other information required to make an ISDN connection.

Terminal Adapter AT Commands & S-Registers
Standardized ISDN signalling protocols such as DSS1, DSS2, and SS7 support sending complete indication, a signal that no more digits will follow. Adding such a signal to a telephone number is often impractical; therefore, many private networks send the number of a called party using a procedure called overlap sending, in which no sending complete indication is sent. Computer users can automatically append the sending complete indication to the telephone number by choosing the en bloc method of sending, which results in faster call setup. Use the %A97= command to select between the two methods.
%A97=0 En bloc sending during call SETUP
%A97=1Overlap sending during call SETUP
Selects one of the network switch types supported by the ISIHP-2S/2U. International factory default setting is !C0=1 (Northern Telecom DMS- 100). Default for USA is !C0=5 (USAUS N1-1).
!C0=1 Northern Telecom DMS-100
!C0=2 NET3 (Euro ISDN)
Specifies the channel 0 service profile identifier (SPID) that the ISDN service provider assigned at subscription time. The data SPID string can have up to 20 characters.
*!C6=n SPID 1

Terminal Adapter AT Commands & S-Registers
Specifies the channel 1 service profile identifier (SPID) that the ISDN service provider assigned at subscription time. The voice SPID string can have up to 20 characters.
Sets the terminal endpoint identifier (TEI) for channel 0. A TEI is a number used by the central office switch to identify uniquely each device that is connected to the network. When it uses dynamic TEI assignments (auto TEI), the central office switch assigns a TEI each time the TA connects to the network. If your ISDN service provider assigned a fixed TEI at subscription time, you must configure the TA with the fixed TEI number.
You can also use !D3= to disable the data channel, which may be useful when multiple TAs are attached to a network terminator bus.
!D3=063 Sets the TEI to a fixed value from 0 through 63
!D3=240 Sets the data channel for dynamic TEI negotiation (factory default)
*!D3=n TEI 1 Values: n = 063, 240 (auto), 241 (disable) Default: *!D3=240 (Auto TEI) Sets the terminal endpoint identifier (TEI) for channel 1. A TEI is a number used by the central office switch to identify uniquely each device that is connected to the network. When it uses dynamic TEI assignments (auto TEI), the central office switch assigns a TEI each time the TA connects to the network. However, the ISDN service provider may assign a fixed TEI at subscription time, in which case you must configure the TA with the fixed TEI number.
!D3=241 Disables TEI

Terminal Adapter AT Commands & S-Registers
*!D3=0-63 Sets the TEI to a fixed value from 0 through 63
*!D3=240 Sets voice channel for dynamic TEI negotiation (factory default)
Displays the current DN, SPID, TEI, Data protocol, and switch type.
!L Displays the current network configuration
Records and analyzes various protocols on the B-channel, D-channel, and DTE-DCE interface. The Embedded Protocol Analyzer is useful as a diagnostic tool, in that essential data messages display, which enables you to observe interactive operations of the TA, Central Exchange, and remote communications equipment.
>D0 Displays B-channel traffic, decoded as V.120
>D1 Displays D-channel traffic, decoding layers 2 and 3 (Q.921 and Q.931)
>D2 Displays D-channel traffic, decoding layer 2 only (Q.921)
>D3 Displays D-channel traffic, decoding layer 3 only (Q.931)
>D5 Displays async PPP data
>D6 Displays sync PPP data
>D98 Disables Embedded Protocol Analyzer, buffered data unchanged
>D99 Enables Embedded Protocol Analyzer, clearing buffered data
*!D3=241 Disables TEI

Terminal Adapter AT Commands & S-Registers
!N1=n DN0 Sets the Data Directory Number /Multiple Subscriber Number (DN/MSN) for data ports 1 and 2. The DN/MSN is a number assigned to the BRI at subscription time by the ISDN service provider. The DN/MSN is a string of up to 25 characters; valid characters are 0-9, the * character, and the # character. If used as an MSN, a subaddress can be added to the number (if one is needed) by using the : character followed by the subaddress number.
!N1=n sets the Data DN/MSN for port 1
!N2=n sets the Data DN/MSN for port 2
Usage: !N1=n Function:Data DN/MSN Values: n = 25-character string Default: null string Description: Data DN/MSN 1 can be set to the same value as Data DN/MSN 2 and it can also be set to the same value as Modem DN/MSN 1 and/or 2. A call accepted by Data DN/MSN 1 will be routed to TA port 1.
Usage: !N2=n Function: Data DN/MSN 2 Values: n=25-character string Default: null string Description: Data DN/MSN 2 can be set to the same value as Data DN/MSN 1 and it can also be set to the same value as Modem DN/MSN 1 and/or 2. A call accepted by Data DN/MSN 2 will be routed to TA port 2.
Usage: !DNn Function: Disable Data DN/MSN n Values: n=1 (disable Data DN/MSN 1), n=2 (disable Data DN/MSN 2) Default: All ports are enabled by default Description: !DNn disables a Data DN/MSN which will effectively disable the associated TA port from receiving any data calls. However, the port will still be able to

Terminal Adapter AT Commands & S-Registers
originate data calls. This is useful for applications where a specific port is for dial-out only.
Usage: !ENn Function: Enable Data DN/MSN n Values: n=1 (enable Data DN/MSN 1), n=2 (enable Data DN/MSN 2) Default: All ports are enabled by default Description: !ENn enables a Data DN/MSN which will put it back in service for accepting and originating data calls. *!N1=n DN 1 Sets the Modem Directory Number /Multiple Subscriber Number (Modem DN/MSN) for modem ports 1 and 2. TheModem DN/MSN is a number assigned to the BRI at subscription time by the ISDN service provider. The Modem DN/MSN is a string of up to 25 characters; valid characters are 0-9, the * character, and the # character. If used as an MSN, a subaddress can be added to the number (if one is needed) by using the : character followed by the subaddress number.
*!N1=n sets the Modem DN/MSN for port 1
*!N2=n sets the Modem DN/MSN for port 2
Usage: *!N1=n Function: Modem DN/MSN 1 Values: n=25-character string Default: null string Description: Modem DN/MSN 1 can be set to the same value as Modem DN/MSN 2 and it can also be set to the same value as Data DN/MSN 1 and/or 2. A call accepted by Modem DN/MSN 1 will be routed to the first modem.
Usage: *!N2=n Function: Modem DN/MSN 2 Values: n=25-character string Default: null string Description: Modem DN/MSN 2 can be set to the same value as Modem DN/MSN 1 and it can also be set to the

Terminal Adapter AT Commands & S-Registers
same value as Data DN/MSN 1 and/or 2. A call accepted by Modem DN/MSN 2 will be routed to the second modem.
Usage: *!DNn Function: Disable Modem DN/MSN n Values: n=1 (disable Modem DN/MSN 1), n=2 (disable Modem DN/MSN 2) Default: All ports are enabled by default Description: *!DNn disables a Modem DN/MSN which will effectively disable the associated modem port from receiving any modem calls. However, the port will still be able to originate modem calls. This is useful for applications where a specific port is for dial-out only.
Usage: *!ENn Function: Enable Modem DN/MSN n Values: n=1 (enable Modem DN/MSN 1), n=2 (enable Modem DN/MSN 2) Default: All ports are enabled by default Description: *!ENn enables a Modem DN/MSN which will put it back in service for accepting and originating modem calls.
Selects the rate adaptation protocol used to communicate with another terminal adapter. The local and remote terminal adapters must be set to the same protocol for communication to take place.
!Z=5 V.120 protocol
!Z=6 V.110 protocol
!Z=12 X.75 protocol
!Z=9 PPP protocol

Terminal Adapter AT Commands & S-Registers
Use the following commands to control the interaction between the TA and the computer connected to it.
When you enter commands, the TA echoes the characters back to the computer or terminal where they appear on the monitor. This command turns this feature on and off.
L5 and L6 List Active Profile Values: n = 5 or 6 Default: none
Lists current operating parameters of the TA. This information is useful when changing communications software or when changing default settings. ATL5 lists AT command parameters, and ATL6 lists values currently stored in the S-Registers.
L8 Lists Low Level ISDN Status
Controls whether the TA sends result codes to the computer. (Use the V command to select the format of the result codes.)
Q0 Enable result codes. Q1 Disable result codes (quiet mode) for applications such as computer-controlled auto dialing.
Sr=n Set S-Register Values: r = 0, 25, 7, 8, 10, 25, 32, 34, 50, 52-57, 75- 77, 80; n varies Default: None
E0 Echo off · E1 Echo on

Terminal Adapter AT Commands & S-Registers
Sets the value of an S-register, where r is the number of the S-register, and n is the value you want to set.
Sr? Read S-Register Values: r = 05 (S1 is read only) , 7, 8, 10, 25, 32, 34, 50, 52-57, 75-77, 80; n varies Default: None
Reads the value of an S-register, where r is the number of the S-register.
Controls whether the TAs result codes display as digits (terse) or as words (verbose). (Use the Q command to enable or disable the display of result codes.)
V0 Enable terse result codes. V1 Enable verbose result codes.
(Disable printing CLI with CONNECT message)
Selects the result code messages that the TA sends to the computer.
X0 Enables messages OK, CONNECT, RING, NO CARRIER, and ERROR (terse result codes 04).
X1 Enables all messages except BUSY (terse result codes 05, 1014, 1719, 28, and 32). If a call is placed to a busy line, NO CARRIER displays.
X2 Enables all messages (terse result codes 0 5, 7, 1014, 1719, 28, and 32).
X4 Disables printing Calling Line Identification (CLI) at the end of the CONNECT message line. This command does not affect X0, X1, nor X2.

Terminal Adapter AT Commands & S-Registers
X5 Enables printing Calling Line Identification (CLI) at the end of the CONNECT message line. This command does not affect X0, X1, nor X2.
Z Reset to Stored Profile Values: none Default: none
Resets TA to its current power-up profile and clears the command buffer. The result is the same as turning the TA off and on. When you type ATZ, the state of the &W command determines where default values originate. &W0 defaults come from the customized configuration in NVRAM, and &W1 defaults come from the factory default configuration in ROM. Because Z clears the command buffer, it must be the last command in a command string; normally it is issued by itself: ATZ. Note that whereas the &F0 reset command always restores the factory default profile, the Z reset command restores either the factory default or the stored profile, depending on how the &W command is set.
Controls behavior of the DCD (Data Carrier Detect) signal. Normally, the DCD goes high when the TA establishes a connection and drops when the connection is lost. However, you can force DCD to remain high at all times or to remain high except for a brief drop following a disconnect.
&C0 DCD is forced high at all times.
&C1 DCD goes from low to high when TA establishes a connection (DCD normal).
&C2 DCD drops briefly following a disconnect, then rises again. Register S10 defines how long the DCD signal remains low after a disconnect.
&Dn DTR Control Values: n = 0, 1, 2, or 3 Default: &D1 (Exits Data Mode and reenters AT
command mode)

Terminal Adapter AT Commands & S-Registers
Controls how the TA responds to the DTR (Data Terminal Ready) signal. A high DTR signal tells the TA that the connected computer is ready to communicate.
&D0 TA ignores the DTR signal.
&D1 If DTR lowers when the TA is online, TA hangs up, returns to command mode, and disables autoanswer. If the TA is offline, it doesnt answer or dial while DTR is low.
&D3 When DTR lowers, the TA resets the data port and disables autoanswer. If DTR lowers when the TA is online, the TA hangs up, resets the active configuration to the stored configuration, and disables autoanswer.
&D4 &D4 will ignore DTR only when answering a data call. If DTR is low when an incoming data call is present, the TA will answer the call. If DTR goes high during that call, nothing will happen. However, if DTR goes high and then drops for the minimum time specified by S25, then the call will be disconnected just as it would with &D1. &D4 is the same as &D1, except that &D4 can answer a data call without DTR and DTR can remain low for the duration of the call. But if DTR goes high, then &D4 will behave like &D1.

Terminal Adapter AT Commands & S-Registers
Selects method by which the TA controls the flow of data to and from the computer, to prevent either device from accepting data faster than it can handle. The TA provides flow control in both directions. When the TA halts data flow, it is called flow control; when the computer halts data flow, it is called pacing.
&E3 Disable flow control by the TA.
&E4 Hardware flow control. &E4 causes the TA to use the CTS signal to regulate flow control. When CTS goes low, data flow from the computer is suspended until CTS goes high again. This method works with pacing, which uses the RTS signal on pin 4. Hardware flow control cannot be enabled unless an error correction protocol is selected.
&E5 XON/XOFF flow control. This is an in-band method, where the XON and XOFF characters (^Q and ^S, respectively) are inserted into the data stream, rather than using separate control lines. When an XOFF character is detected, the data stream is suspended until an XON character is detected. The drawback to this method is that some files may contain these characters, causing the file transfer to be suspended indefinitely.
&E6 When XON/XOFF pacing is active, the TA responds to and discards the XON/XOFF characters from the computer.
&E7 When XON/XOFF pacing is active, the TA responds to the XON/XOFF characters and passes them through the communications link to the remote device, thereby pacing the remote terminal adapter as well.
&E13 Enables pacing.
&E12 Disables pacing

Terminal Adapter AT Commands & S-Registers
#Xn Send Single/Multiple Xoff Characters Values: n = 0 or 1 Default: #X0
Allows the TA to send either a single or multiple Xoff characters to exert flow control to the terminal. The #X0 command (factory default setting) causes one Xoff to be sent until the TAs buffer reaches the Xon level. The #X1 command causes an Xoff to be sent for every character received after the TA reaches its buffer full level.
#X0 One Xoff character sent until the buffer reaches the Xon level (default)
#X1 Multiple Xoff characters sent for every character received after buffer reaches the full level.
&Fn Load Quick Setup Profile Values: n = 0-4 Default: &F0
For quick setup, the TA includes Quick Setup Profiles. Each contains configuration parameters for a specific type of port operation. To load a Quick Setup Profile into active memory use the command &Fn, where n is the number of the profile you want to load. You then can customize the profile and store it with the &W command, so it loads automatically on power-up or reset. These profiles are stored in permanent memory and are not user-configurable.
&F0 Profile 0 Modem-like async operation (default)
&F1 Profile 1 V.110 async operation
&F2 Profile 2 V.120 async operation
&F3 Profile 3 X.75 async operation
&F4 Profile 4 PPP async operation

Terminal Adapter AT Commands & S-Registers
Allows you to control the state of the CTS (Clear to Send) signal. Normally the CTS signal follows the state of the RTS signal when TA is online.
&R0 CTS acts normally; that is, it follows RTS.
&R1 CTS is forced high, but still provides online flow control.
&R2 CTS is forced high, but it drops on disconnect for the period of time set by S10. CTS still provides flow control when the TA is online.
Controls the state of the DSR (Data Set Ready) signal on the RS232E/V.24 interface. A high DSR signal indicates to the computer that the TA is ready to transmit data.
&S0 DSR is always high.
&S1 DSR acts normally; that is, it follows the state of the CD signal, which goes high when the ISIHP-2S/2U detects a carrier signal, and goes low when the carrier signal is lost.
&S2 DSR is always high, except on disconnect, when it drops for the period of time set by S10 and then goes high again.
&Vn View Port Configuration Parameters Values: n = 0, 1, 2 Default: n/a
Allows you to view the port configuration parameters for ports 0 and 1. This listing is the equivalent of both L5 and L6 combined.
&V0 Displays port 0 configuration parameters.
&V1 Displays port 1 configuration parameters.
&V2 Displays both port 0 and port 1 configuration parameters.

Terminal Adapter AT Commands & S-Registers
Stores your active profile, or configuration, in memory, so you dont lose your custom settings when you turn off the TA or reset it.
&W0 Stores all current AT command and S- register values in nonvolatile random access memory (NVRAM) and configures the TA so it reads your custom settings in NVRAM when the modem is turned on or when it is reset with the Z command. (The &F reset command continues to read the factory default settings in ROM.)
&W1 Erases your custom settings in NVRAM the next time the TA is turned off or reset, causing the TA to read the factory default settings in ROM whenever it is turned on or reset.
Allows you to store a telephone number in a memory register for faster dialing. To store a number, type &Z, the register number (09) where you want to store the number, the = character, and the dialing string you want stored. Then press ENTER. The dialing string can have up to 80 characters. To read a stored number, type AT&Zn? (e.g., AT&Z4?) where n is the number of the register you want to read. To display a list of all numbers stored in memory, type ATL and press RETURN:

Terminal Adapter AT Commands & S-Registers
DSn Dialing a Stored Telephone Number Values: n = 09 Default: n/a
To dial a stored telephone number, type ATDSn in terminal mode, where n is the location of the number you want to dial. For example, typing ATDS6 <cr> dials a telephone stored in memory register 6 location.
Enables or disables persistent DTR dialing (PDD). PDD causes the terminal adapter to automatically and continually redial stored telephone number 0 when the port has no active calls and DTR is high.
By default, the modem responds only to the +++ escape method. However, you can use the %E command to set the modem to respond only to the method, to respond to either +++ or the method, or to ignore both methods and not escape.
%E0 Modem wont escape
%E1 +++ escape method
%E2 escape method
%E3 Both +++ and escape methods
%E4 Disable OK response to +++
%E5 Enable OK response to +++
%E1 %E5 Enable +++ method and OK response

Terminal Adapter AT Commands & S-Registers
%E3 %E5 Enable +++ or method and OK response to +++
Use only to set the type of parity the TA uses when turned on. Once the TA receives an AT command from the computer, it automatically adjusts to parity the computer is using.
Use only to set the number of data bits the TA uses when turned on. Once the TA receives an AT command from the computer, it automatically adjusts to the number of data bits the computer is using.
@P4=7 7 data bits
@P4=8 8 data bits
Use only to set the number of stop bits the TA uses when turned on. Once the TA receives an AT command from the computer, it automatically adjusts to the number of stop bits the computer is using.
@P6=1 1 stop bit
@P6=2 2 stop bits

Terminal Adapter AT Commands & S-Registers
Data Call Commands Use these commands to make or configure data calls.
Forces TA to answer an incoming call. To cause the TA to autoanswer, set register S0 to a value higher than 0.
Causes TA to dial a telephone number (e.g., ATD785-3500 <cr>).
Forces TA to go off-hook (take control of the telephone line) or go on-hook (hang up). Since TA goes off-hook automatically when it dials, H command normally is used only to hang up. To hang up, first escape to command mode (+++AT <cr>), then type ATH (or ATH0) <cr>. Or, include the hang up command in the escape sequence: +++ATH <cr>.
H0 Go on-hook (hang up).
H1 Go off-hook.
Displays the following TA product information:
I0 Product ID (e.g., 247) I1 Firmware version number (e.g., 1.00) I2 Model number

Terminal Adapter AT Commands & S-Registers
Returns TA to online mode from the online command mode. When TA makes a data connection, it enters online data mode. The TA typically remains in this mode until it receives an escape sequence or until the call ends. When it detects an escape sequence, the TA enters online command mode, where it can accept AT commands while retaining the online connection. To return the TA to online mode from the online command mode, enter the command ATO and press ENTER.
Starts TAs internal configuration utility, which allows you to customize the configuration for your application. Enter the command while in terminal mode. Terminal Adapter S-Registers
S-registers are sections of memory in which values are stored that affect how the TA operates. S-registers are so-called because each has a name that begins with the character S. Use the S command to assign a value to or to read the current value of an S-register. To assign a value to an S-register, use the command Sr=n, in which r is the register number, and n is the value you want to assign to the register, e.g., S7=45. To read an S-register value, use the command Sr?, in which r is the register number, e.g., ATS7?.
S-Register Function S0 Rings until answer S1 Ring count S2 Escape character S3 Carriage return character S4 Line feed character S5 Backspace character S7 Wait for connection (abort timer) S8 Pause Time for Comma S10 DCD Drop Time S25 DTR Drop Time
S-Register Summary

Terminal Adapter AT Commands & S-Registers
S30 Online Inactivity S32 Escape sequence timeout S34 Maximum escape sequence length S50 Caller line ID (CLI) S52 Auto-protocol detection S54 Forces 56KBps B-Channel Data Rate S55 POTS Port Call Control S56 Calling Party Number IE Settings S57 Called Party Number IE Settings S75 Maximum V110 Network Rate S76 V110 Network Rate S77 V110 Network Rate Control S80 Persistent DTR Dialing Delay
S0 Number of Rings Until Answer Unit: 1 ring Range: 0255 Default: 1
Sets the number of rings the TA waits for before it answers and begins its connect sequence. S0=0 turns off the ability to automatically answer a call. S0=1 causes the TA to automatically answer after 1 ring. Note that if the S0 value is set too high, the calling device may time out before the TA answers the call. For autoanswer, S0 must have a nonzero value, DTR must be high (&D command), and the TA must be offline.
Counts the number of rings that have occurred, up to a maximum of 255. It is a read-only register and is seldom, if ever, used in typical operation.

Terminal Adapter AT Commands & S-Registers
Specifies the character used by the TA to escape from data mode and return to command mode.
Specifies the character used by the TA to indicate the end of a command line.
Specifies the character used by the TA to indicate the end of a status message.
Specifies the character used by the TA to delete the previous character in command line.
S7 Wait for Connection (Abort Timer) Unit: 1 second Range: 0255 Default: 45
Sets Abort Timer delay time, which is the length of time TA waits for a connection after dialing. If no connection is established during the specified time, the TA ends the call.
S8 Pause Time for Comma Unit: 1 second Range: n=0-255 Default: 2 (= 2 seconds) S8 sets the length of the pause caused by a comma inserted in a dialing command. The default setting is 2 seconds, where each unit is one second. S8 may be set for up to 255 seconds.

Terminal Adapter AT Commands & S-Registers
Sets the amount of time the DCD signal will be dropped when a call is disconnected if the DCD signal is configured for a momentary drop on disconnect (&C2)
Sets the time that DTR must remain low before the TA disconnects. The S25 unit value for 0 is 40 ms. For values from 1 through 255, the unit value is 100 ms.
n=1255 Default: 0 (does not disconnect) Makes the TA disconnect a data connection if no data is transmitted or received for the specified time. It will NOT cause a POTS call (voice/ modem/fax) to disconnect. The timer restarts any time a data character passes through the serial port (either sent or received). Disable the inactivity timer by setting S30=0, which is the factory default setting. S30 currently works for + all protocols EXCEPT V.110.
Sets the time allowed in an escape sequence from the receipt of the A in AT to the receipt of the carriage return. If the S32 time interval expires before you press ENTER, the escape sequence ends. The default time is 2 seconds.

Terminal Adapter AT Commands & S-Registers
S34 Maximum Escape Sequence Length Unit: Decimal ASCII code Range: 010 Default: 2 Sets the maximum character length of the escape sequence, not including +++AT. For example, a character length of S34=2 allows two characters after +++AT (e.g., +++ATH0). Conversely, an invalid escape sequence (too many characters placed in the command string) passes through as data (e.g., +++atili2). The maximum length of the escape sequence is 10 characters.
S50 Caller Line ID CLI Unit: Decimal ASCII code Range: 0 or 1 Default: 0 (disable CLI)
Sets whether the mechanism for identifying the two endpoints of a connection is enabled or disabled. Since RING messages only appear for ISDN data calls, the CLI feature does not define a means of conveying Calling Party information to the terminal for ISDN voice calls. The CLI information is only included with the first RING message for a given incoming call, and appears as follows:
If the Calling Party Number information is not included in the incoming SETUP message, the RING message appears as follows:
If the Called Party Number information is not included in the incoming SETUP message, the RING message will appear as follows:
If neither the Called Party Number nor the Calling Party Number is included in the incoming SETUP message, the RING message will contain no additional information.

Terminal Adapter AT Commands & S-Registers
n=1Detect, n=2Detect and Select Default: 1 (Detect) Enables or disables the ability to identify the reception of V.110, V.120, X.75, or PPP data calls. The TA determines the type of call by checking for protocol information in the SETUP message or by matching protocol information received on the B-channel once connected if no protocol information is available in the SETUP message. Once the protocol is determined, the TA will switch its data protocol to match. Upon disconnect the TA will revert its data protocol selection back to the protocol that was selected before the call was received when S52=1 Detect. If S52=2 Detect and Select, then the TA will not revert the protocol selection, rather it will keep the detected data protocol as the new protocol selection. Detect and Select is useful for applications where the TA receives a call and then the software performs callback. Callback calls should be made with the same protocol that was used by the client so Detect and Select enables this possibility. However, if an initialization string or &Fn command is given to the TA that changes the protocol after the disconnection, then Detect and Select will not be effective. Make sure no commands are given to the TA that will change the data protocol when using Detect and Select if callback is involved to ensure that the callback call uses the correct data protocol.
S54 Force 56 Kbps B-Channel Data Rate Unit: Decimal ASCII code Range: n=56 (Kbps) or 64 (Kbps) Default: 64 (Kbps) S54 can be used to force a 56 Kbps B-channel data rate in order to make 56 Kbps data calls.
S55 POTS Port Call Control Unit: Decimal ASCII code Range: 1, 2, 17, 18 Default: 1 Allows you to set the type of information transfer capability for calls placed from the POTS port either by a telephone, modem, or fax. Some Central Office (CO) switches keep track of the type of line each customer has, and if that line is labeled as a data line (modem or fax), it will not accept a

Terminal Adapter AT Commands & S-Registers
speech call originated on that line. However, 3.1 kHz audio information transfer capability is allowed on data lines (modem or fax) by most switches. S55 also lets you define whether a progress indicator information element (which indicates that the origination address of the POTS call is non-ISDN) is sent with the SETUP message for the POTS port call. This may help POTS port calls get through certain CO switches.
S1 Speech, no progress indicator S2 3.1 kHz Audio, no progress indicator S17 Speech, origination address is non-ISDN S18 3.1 kHz Audio, origination address is non-ISDN S56 Calling Party Number IE Settings (applies to NET3 [!C0=2] switch type only) Unit: decimal ASCII code Range: 128 Disable Type of Number 0 Unknown, 16 International 32 National 48 Network specific 64 Subscriber 96 Abbreviated Numbering Plan 0 Unknown 1 ISDN/telephony 3 Data 4 Telex 8 National standard 9 Private Default: 128 (disabled) Modifies the value of Octet 3 of the Calling Party Number Information Element that is sent within the SETUP message for data and POTS port (voice/modem/fax) calls. To set a specific number type and numbering plan, select an option from the Type of Number section above and add its value to the value of an option in the Numbering Plan section above. For example, a National/ISDN Calling Party Number IE would be S56=33, where 32 (National) + 1 (ISDN/telephony) = 33 (National/ISDN). If there is no Data Directory Number (for data calls) nor Voice Directory Number (for voice/modem/fax calls), no Calling Party Number IE is sent. By

Terminal Adapter AT Commands & S-Registers
default S56=128, which means no Calling Party Number IE is sent.
S57 Called Party Number IE Settings (applies to NET3 [!C0=2] switch type only) Unit: decimal ASCII code Range: 128 Disable Type of Number 0 Unknown, 16 International 32 National 48 Network specific 64 Subscriber 96 Abbreviated Numbering Plan 0 Unknown 1 ISDN/telephony 3 Data 4 Telex 8 National standard 9 Private Default: 128 (disabled) Modifies the value of Octet 3 of the Called Party Number Information Element that is sent within the SETUP message for a data call and within each INFORMATION message that is sent when dialing from the POTS port. To set a specific number type and numbering plan, select an option from the Type of Number section above and add its value to the value of an option in the Numbering Plan section above. For example, a National/ ISDN Called Party Number IE would be S57=33, where 32 (National) + 1 (ISDN/telephony) = 33 (National/ISDN). By default S57=128, which means no Called Party Number IE is sent.
S75 Maximum V.110 Buffer Size Unit: 1 byte Range: n=0 (256 bytes),
n=64-255 Default: 0 (256 bytes) S75 allows the maximum V.110 buffer size to be customized. An adjustable packet size can provide higher compatibility with devices that cannot handle a large delay. Reducing the V.110 buffer size reduces delay.

Terminal Adapter AT Commands & S-Registers
n=21200 bps, n=32400 bps, n=44800 bps, n=59600 bps, n=619200 bps, Default: 6 (19200 bps) If S77=1, then the network rate of the V.110 connection will match that of S76 ($MB). If a V.110 call is received and S77=1, then the incoming V.110 network rate must match S76 ($MB) or the connection will fail. If S77=2 and a V.110 call is received, then the setting of S76 ($MB) will have no effect on the network rate of that call (see S77 for a description for this case). The value of S76 will change if $MB is changed and the value of $MB will change if S76 is changed.
S77 V.110 Network Rate Control Unit: decimal Range: n=1 (use $MB (S76)),
n=2 (use $MB (S76)) or Auto Sync on Answer) Default: 2 (use $MB(S76) or Auto Sync on Answer) The Network Rate for an originated V.110 call will be determined by S76 ($MB) for both S77=1 and S77=2. If the Network Rate of the originated call does not match that of the peer device, then the connection will fail if the peer does not support automatic rate synchronization. If the terminal adapter answers a V.110 call, and if S77=1, then the incoming V.110 Network Rate must match that of the S76 register ($MB) or else the connection will fail. If S77=2, then the terminal adapter will auto- synchronize on the incoming V.110 Network Rate.
S80 Persistent DTR Dialing Delay Usage: S80=n; S80? Unit: 1 second Range: n=1-255 (1-255 seconds) Default: 5 ( = 5 seconds) Once DTR is detected as present (active high) and other conditions required for the TA to dial are met, a delay of S80 seconds will occur before stored number 0 is dialed. Some conditions include the TA not being in the

Terminal Adapter AT Commands & S-Registers
@CONFIG menu, not having a data call present at the time, and Persistent DTR Dialing must be enabled. By default the TA will delay for 5 seconds before dialing when all conditions are satisfied.
When the TA receives an AT command from the computer or terminal, it attempts to execute the command, then sends a status message to the computer or terminal that reports the result of the command. The TA provides you with several of these response messages, or result codes, which can be displayed on your monitor or intercepted and used by your communications software. Using the V command, you can select whether the result codes are terse (numbers) or verbose (words).
The TAs result codes are listed in the following table. Note that the speed of an ISDN channel is always either 56 Kbps or 64 Kbps. CONNECT messages indicate the speed of the connection between the TA and your computer or terminal.
Terse Verbose 0 OK 1 CONNECT 1P CONNECT/PPP 1PC CONNECT/PPP COMPRESSED 1T CONNECT/V.110 1V CONNECT/V.120 1VC CONNECT/V.120 COMPRESSED 2 RING 3 NO CARRIER 4 ERROR 5T CONNECT 1200/V.110 6 NO DIALTONE 7 BUSY 9T CONNECT 600/V.110 10T CONNECT 2400/V.110

Terminal Adapter AT Commands & S-Registers
11T CONNECT 4800/V.110 12T CONNECT 9600/V.110 14T CONNECT 19200/V.110 28T CONNECT 38400/V.110 56 CONNECT 56000 56P CONNECT 56000/PPP 56PC CONNECT 56000/PPP COMPRESSED 56V CONNECT 56000/V.120 56VC CONNECT 56000/V.120 COMPRESSED 56X CONNECT 56000/X.75 56XC CONNECT 56000/X.75 COMPRESSED 64 CONNECT 64000 64P CONNECT 64000/PPP 64PC CONNECT 64000/PPP COMPRESSED 64V CONNECT 64000/V.120 64VC CONNECT 64000/V.120 COMPRESSED 64X CONNECT 64000/X.75 64XC CONNECT 64000/X.75 COMPRESSED 65 CONNECT MODEM Using AT Commands to Operate the Terminal Adapter
You can configure and operate the Terminal Adapter entirely with AT commands, if you want. Remember, you can issue AT commands only from a terminal or from a computer running a communications program in terminal mode. This section describes how to use AT commands for basic operations such as calling, answering a call, and hanging up.
The TA has three modes of operation: offline command, online command, and data.
Offline Command Mode In offline command mode, the TA communicates with the terminal or

Terminal Adapter AT Commands & S-Registers
computer and responds to AT commands. There is no data communications link with a remote device.
Data Mode The TA enters data mode when it makes a successful data communications link with a remote device. In data mode, the TA can send and receive data, but it does not respond to AT commands. Instead, it treats them as data, and transmits them to the remote device.
Online Command Mode In online command mode, the TA responds to AT commands while maintaining a data communications link; however, transmission of data is suspended. To enter online command mode from data mode, type the escape sequence +++AT<cr>. To return to data mode from online command mode, type ATO<cr>.
Before you can place a data call, you must configure the TA for the local switch type, serial port speed, and the data type of the ISDN device you want to call.
Dialing To dial a number using AT commands, you must first start a data communications program. In the programs terminal mode, type ATDxxxxxxx<cr>, where xxxxxxx is the telephone number you want to dial, and is the carriage return character that is sent when you press ENTER , e.g, ATD7853500<cr>. The dial string can contain up to 80 characters.
To make it easier to read the dial string, you can use hyphens, spaces or parentheses. These characters are ignored by the TA. For example, the TA would read the following dial strings the same way:
ATD16127853500 <cr> ATD 1-612-785-3500 <cr> ATD 1 (612) 785-3500 <cr>

Terminal Adapter AT Commands & S-Registers
Canceling a Call To cancel a call before the TA makes a connection, press any key.
Storing a Telephone Number To store a telephone number, type &Zn=x in terminal mode, where n is the number of the memory register in which the number is to be stored, and x is the dial command string that you want to store. For example, type AT&Z9=612- 785-3500 <cr> to store the number 612-785-3500 in memory register 9.
Dialing a Stored Telephone Number To dial a stored telephone number, type DS=n in terminal mode, where n is the location of the number you want to dial. For example, type ATDS=3 <cr> dials a telephone stored in memory register 3 location.
Displaying a Stored Number To display a stored telephone number, type &Zn? in terminal mode, where n is the memory register where the number is stored. For example, type AT&Z5? <cr> to display the telephone number in memory register 5. To list all ten telephone numbers stored in memory, type ATL <cr>.
You can answer incoming calls to the TA either manually or automatically. When the TA detects an incoming call, it turns on the RI signal on the V.24 interface and sends a RING result code to the computer or terminal after each ring. If you enable autoanswer, the TA automatically answers the call. To manually answer the call, use the A command.
Answering Manually If your communication program is in terminal mode when the RING result code appears on your monitor, manually answer the call by typing ATA <cr>.
Answering Automatically To set the TA to answer a call automatically :

Terminal Adapter AT Commands & S-Registers
of rings.
The TA answers the call after the number of rings specified by S0. To disable autoanswer, use a configuration utility or the command S0=0.
Answering Using Call Steering Call Steering lets you set up the Data DN/MSN numbers and/or Modem DN/MSN numbers so that calls to specific numbers will be steered to the respective Data or Modem port. If a DN/MSN is left blank, then the TA assumes the port can accept a call to any number. A port that is given a specific DN/MSN has priority over a port that has a blank DN/MSN. If a port with a specific DN/MSN is busy, then the call will be steered to another available port if that ports DN/MSN matches or is blank. Otherwise if a port is busy and there is no other available port or no other port that matches the called number, then the TA will report a busy. Data DN/MSN 1 will steer calls to the first Data (TA) port. Data DN/MSN 2 will steer calls to the second Data (TA) port. Modem DN/MSN 1 will steer calls to the first Modem port. Modem DN/MSN 2 will steer calls to the second Modem port. Call Steering is useful for applications where specific ports are tied to specific types of applications or equipment. For example, fax software attached to the second modem port should only receive fax calls (and not dial-up calls). To do this one would set Modem DN/MSN 2 to the desired number that will only receive fax calls. If Modem DN/MSN 1 is left blank and the second port is busy, then fax calls will be steered to port 1. If this is not desired, then set Modem DN/MSN 1 to a number other than that of the number used for faxes.
To hang up a call, first escape to online command mode (+++AT<cr>), then enter the H command (ATH<cr>). The escape sequence and hang up command can be combined into one command string: +++ATH<cr>.

Terminal Adapter AT Commands & S-Registers

Troubleshooting

This chapter covers common problems you may have with your ISIHP and how to solve them. The ISIHP was thoroughly tested at the factory before shipping. If you are unable to connect successfully, or if you experience data loss or garbled characters, during connecting, it is possible the modem or terminal adapter is defective. However, it is more likely that the source of your problem lies elsewhere. Always make sure all hardware is connected properly. Then review the common problems listed in this chapter for recommendations on what to change or do. Problems you may encounter include the following:
The TA/modem does not respond to commands.
The TA/modem dials but cannot make a connection.
You can place data calls but not voice calls, or vice versa.
You cannot place two simultaneous data calls.
The TA/modem disconnects while online.
The TA/modem cannot connect when answering.
File transfer appears slower than it should be.
Data is being lost
There are garbage characters on the monitor
If you experience problems, please check the following possibilities before calling Tech Support (see Chapter 6).
Make sure you issue commands from the data communications
software, either automatically or manually, in terminal mode. (You cannot send commands to the TA/modem from the DOS prompt.)
Make sure you are in terminal mode in your data communications
program; then type AT and press ENTER. If you get an OK response, your connections are good and the problem likely is in your phonebook entry or session settings.
If you dont get an OK, the problem may still be in the
communications software. Make sure you have done whatever is necessary in your software to make a port connection. Not all communications programs connect to the COM port automatically. Some connect when the software loads and remain connected until the program ends. Others, like MultiExpress Terminal, can
Troubleshooting

disconnect without ending the program (make sure the Connect icon looks plugged in). MultiExpress Terminal also allows multiple terminals to be open, but only one can access the modem/TA at a time.
Your communications software settings may not match the physical
port where the TA is connected. The serial cable may be plugged into the wrong connectorcheck your computer documentation to make sure. Or, you may have selected a COM port in your software other than the one where the TA/modem is connectedcompare the settings in your software to the connection.
Peripheral expansion cards, such as bus mouse and sound cards, may
include a serial port preconfigured as COM1 or COM2. The extra serial port, or the card itself, may use the same COM port, memory address, or interrupt request (IRQ) as your communications port. Be sure to disable any unused ports.
To look for address or IRQ conflicts if you use Windows 3.1x, select File then Run in Program Manager. Type MSD and press ENTER. Then select Mouse, COM Ports, and IRQ Status and note the addresses and IRQs that are in use. If you find an IRQ conflict, note which IRQs are not being used, then change one of the conflicting devices to use one of the unused IRQs. If you find an address conflict, change the address of one of the conflicting devices.
To change a port address or IRQ in Windows 3.1x, double-click the Control Panel icon and then the Ports icon. Click the port you want to change; then click Settings and then Advanced and select the new port address and/or interrupt. If you want to use COM3 or COM4, note that COM3 shares an IRQ with COM1, as does COM4 with COM2, so you should change their IRQs to unused ones if possible.
If you use Windows 95, right-click My Computer and select Properties. Click the Device Manager tab and then double-click Ports. Double-click the Communications Port where your modem/ TA is connected. In the ports Properties sheet, click the Resources tab to view the ports Input/Output range and Interrupt Request. If another device is using the same address range or IRQ, it appears in the Conflicting Device List. Remove the check from Use Automatic Settings to change the ports settings, so they do not conflict with the
Troubleshooting

other device. Or, select the port the conflicting device is on and change it instead. If you need to open your computer to change switches or jumpers on the conflicting device, refer to the your computers documentation.
The serial port may be defective. If you have another serial port,
install the TA on it, change the COM port setting in your software, and try again.
The TA may be defective. Call Tech Support for assistance (see
Chapter 6).
The terminal adapter dials but cannot make a connection Possible be several reasons the TA fails to make a connection include:
Lack of a proper physical connection to the communication line
A busy signal
A wrong number
No terminal adapter at the other end
A faulty communications device, computer, or software at the other
Incompatibility between communications devices
An improperly configured ISIHP-2S/2U/4S/4U TA
Narrow the list of possibilities by using extended result codes. To enable them, enter ATV1X2 and press ENTER while in terminal mode or include V1X2 in the TA s initialization string (V1X2 is enabled by default). When you dial again, the TA reports the calls progress.
If the modem/TA reports BUSY, the other number may be busy. Try
again later.
If the TA reports NO CARRIER, no connection was made. You may
have dialed the correct number, but the other computer or software was turned off or faulty. Check the number and try again or try calling another system to make sure your TA is working. Also, check that you accurately configured the TA with the correct switch type, TEIs, data protocols, and other parameters needed for a successful
Troubleshooting · end

call (see Chapter 3).
You might not have ordered both voice and data service from your
ISDN provider. Check your contract or latest statement of service from your ISDN provider.
Your ISDN provider may have programmed the switch incorrectly.
Call the provider.
You may not have ordered an ISDN line configuration that supports
two simultaneous calls. Check your contract or latest statement of service from your ISDN provider. Also, your ISDN provider may have programmed the switch incorrectly. Call the provider.
You may have misconfigured your TA to dial two simultaneous data
calls. The command AT&J1&W0 is used to indicate whether outgoing calls should be made on two B-channels by default.
You may be using the wrong bundling dial modifier (e.g.,
ATD7853500&7853502). The ampersand in this command string is correct. Note other valid characters joining two telephone numbers include a Plus Sign (+) and an exclamation Mark (!).
Note: In Windows 95, if the Use Country Code and Area Code box is checked in the Properties window for dial-up connection, the bundling modifier (i.e., &, + or !) is removed from the dialing string when the user attempts to make a connection. The solution is to not check the Use Country Code and Area Code box or to simply add the bundling dial modifier to the phone number at the time of connection.
Check for loose connections between the computer, the ISDN jack,
and AC power.
The problem may have originated at the other end of the line. Try
again.
If you were online with a BBS or online service, it may have hung up
due to lack of activity on your part or because you exceeded your
Troubleshooting

time limit for the day. Try again.
Autoanswer may be disabled. Turn on autoanswer in your data
communications program, or send the command ATS0=1 to your TA in terminal mode.
If you have a Universal Asynchronous Receiver/Transmitter (UART)
that is compromising data throughputs, we recommend you replace it with a special I/O card.
If you are running under Windows 3.1 and have a 16550AFN UART,
you must replace the Windows serial driver, COMM.DRV, to take full advantage of the UARTs speed.
Check the serial port baud rate in your communications software and
make sure it is set as high as your UART allows.
Your UART may not be reliable at serial port speeds over 9600 bps
or 19,200 bps. Reset your serial port speed to a lower rate or replace your serial port with a faster one.
Check the serial port baud rate in your communications software, and
make sure it is set as high as your UART allows.
Make sure the flow control method you selected in software matches
the method selected in the TA.
Your computer and the remote computer may be set to different
parities. Check with the remote system with which you are communicating and set your communications software to use the same parity as the remote system. communicating and set your communications software to use the same parity as the remote communicating and set your communications software to use the same parity as the remote system.
Troubleshooting

Regulatory Information

Regulatory Information

Multi-Tech Systems or its licensees. Unauthorized repairs void registration and warranty.
2205 Woodale Drive Mounds View, MN 55112 (612) 785-3500 Fax (612) 785-9874
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
This device may not cause harmful interference.
This device must accept any interference that may cause undesired
operation.
Regulatory Information

This Class A digital apparatus meets all requirement so the Canadian Interference-Causing Equipment Regulations.
Cet appareil numerique de la classe A respecte toutes les exigences du Reglement sur le materiel brouilleur du Canada.
The Telephone Consumer Protection Act of 1991 makes it unlawful for any person to use a computer or other electronic device, including fax machines, to send any message unless such message clearly contains the following information:
Date and time the message is sent
Identification of the business or other entity, or other individual
Telephone number of the sending machine or such business, other
This information is to appear in a margin at the top or bottom of each transmitted page or on the first page of the transmission. (Adding this information in the margin is referred to as fax branding.)
Since any number of fax software packages can be used with this product, users must refer to the their fax software manual for setup details. Typically, the fax branding information must be entered via the configuration menu of the software.
Regulatory Information · sending the message · entity, or individual

Notice: The ringer equivalence number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the ringer equivalence numbers of all the devices does not exceed five.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.
Regulatory Information

The CE mark is affixed to this product to confirm compliance with the following European Community Directives:
Council Directive 89/336/EEC of 3 May 1989 on the approximation of the laws of Member States relating to electromagnetic compatibility,
Council Directive 73/23/EEC of 19 February 1973 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits,
Council Directive 98/13/EC of 12 March 1998 on the approximation of the laws of Member States concerning telecommunications terminal and Satellite earth station equipment.