SAFETY PRECAUTIONSp.3CONDITIONS OF USE FOR THE PRODUCTp.7INTRODUCTIONp.8COMPLIANCE WITH EMC AND LOW VOLTAGE DIRECTIVESp.9RELEVANT MANUALSp.10CONTENTSp.12MANUAL PAGE ORGANIZATIONp.16TERMSp.18PACKING LISTp.18CHAPTER 1 OVERVIEWp.191.1 Featuresp.201.2 Signal Transmission Between the QD73A1 and Othersp.21CHAPTER 2 SYSTEM CONFIGURATIONp.232.1 Applicable Systemsp.232.2 How to Check the Function Version and Serial Numberp.25CHAPTER 3 SPECIFICATIONSp.273.1 Performance Specificationsp.273.2 Number of Parameter Settingsp.283.3 List of Functionsp.293.4 I/O Signals from/to the CPU Modulep.323.4.1 I/O signal listp.323.4.2 Details of input signalsp.343.4.3 Details of output signalsp.393.5 Specifications of I/O Interfaces with External Devicesp.423.5.1 Electrical specifications of I/O signalsp.423.5.2 Signal layout for external device connectorsp.443.5.3 List of I/O signal detailsp.453.5.4 I/O interface internal circuitp.473.6 Memory Configuration and Usep.493.7 List of Buffer Memory Addressesp.50CHAPTER 4 SETTINGS AND PROCEDURE BEFORE OPERATIONp.564.1 Handling Precautionsp.564.2 Settings and Procedure Before Operationp.574.3 Part Namesp.584.4 LEDp.604.5 Zero/gain Adjustmentp.614.6 Wiringp.664.6.1 Wiring precautionsp.664.6.2 Precautions when connecting an encoderp.684.6.3 External device connectorsp.71CHAPTER 5 DATA USED FOR POSITIONINGp.755.1 Types of Datap.755.2 Positioning Parametersp.775.3 OPR Parametersp.815.4 Positioning Datap.845.5 Monitor Datap.875.6 Control Datap.91CHAPTER 6 VARIOUS SETTINGSp.1016.1 Adding a Modulep.1016.2 Switch Settingp.1026.2.1 Rotation direction settingp.1036.2.2 Accumulated pulse settingp.1046.2.3 Multiplication settingp.1066.2.4 OPR direction settingp.1066.2.5 OPR method settingp.1066.2.6 Encoder I/F settingp.1076.2.7 Analog voltage resolution settingp.1076.2.8 Feedback pulse addition/subtraction settingp.1086.2.9 Deviation counter clear settingp.1096.3 Parameter Settingp.1106.4 Positioning Data Settingp.1116.5 Auto Refreshp.112CHAPTER 7 PROGRAMMINGp.1137.1 Precautions on Programmingp.1137.2 Programs for Positioningp.1167.3 When Using the Module in a Standard System Configurationp.1177.3.1 Parameter setting programp.1197.3.2 OPR programp.1217.3.3 Major positioning control programp.1277.3.4 Fixed-feed operation programp.1357.3.5 JOG operation programp.1377.3.6 Control change programp.1397.3.7 Stop program during positioningp.1437.4 When Using the Module in a Remote I/O Networkp.1447.4.1 Parameter setting programp.1517.4.2 OPR programp.1537.4.3 Major positioning control programp.1597.4.4 Fixed-feed operation programp.1697.4.5 JOG operation programp.1727.4.6 Control change programp.1747.4.7 Stop program during positioningp.179CHAPTER 8 OPR CONTROLp.1808.1 Overview of OPR Controlp.1808.2 Near-point Dog Methodp.1818.3 Count Methodp.1838.4 Operation Timing and Processing Time of OPR Controlp.1858.5 OPR Parameter Settingp.186CHAPTER 9 MAJOR POSITIONING CONTROLp.1879.1 Overview of Major Positioning Controlp.1879.2 Data Required for Major Positioning Controlp.1889.3 Relation Between Each Control and Positioning Datap.1899.4 Specifying a Positioning Addressp.1909.5 Checking the Current Valuep.1919.6 Details of Major Positioning Controlp.1929.6.1 Position control modep.1939.6.2 Speed-position control switch modep.1979.7 Operation Timing and Processing Time of Major Positioning Controlp.201CHAPTER 10 JOG OPERATIONp.20210.1 Operation of JOG Operationp.20310.2 Operation Timing and Processing Time of JOG Operationp.20810.3 Data Setting for JOG Operationp.209CHAPTER 11 CONTROL SUB FUNCTIONSp.21011.1 Electronic Gear Functionp.21111.2 Speed Limit Functionp.21311.3 Stroke Limit Functionp.21511.4 Upper Limit Switch (FLS)/Lower Limit Switch (RLS) Functionp.21711.5 Current Value Change Functionp.21911.6 Speed Change Functionp.22011.7 Deviation Counter Clear Functionp.22211.8 In-position Functionp.22311.9 Accumulated Pulse Error Detection Functionp.22511.9.1 Measuring and saving the reference value in the flash ROMp.22711.9.2 Setting the accumulated pulse error detection functionp.228CHAPTER 12 STOPPING AND RESTARTING CONTROLp.23212.1 Stopping Controlp.23212.2 Restarting the Speed-position Control Switch Modep.236CHAPTER 13 COMMON FUNCTIONSp.23813.1 Module Status Monitor Functionp.23813.2 Error History Functionp.24013.3 Module Error Collection Functionp.24113.4 Error Clear Functionp.242CHAPTER 14 TROUBLESHOOTINGp.24314.1 Checking an Error on GX Works2p.24314.2 Troubleshootingp.24714.2.1 Troubleshooting procedurep.24714.2.2 When the motor does not stopp.24814.2.3 When positioning cannot be executedp.24814.2.4 When a positioning error occursp.24914.2.5 When the positioning speed is different from the specified speedp.25014.2.6 When operation stops abnormally during positioningp.25014.2.7 OPR errorp.25114.3 Details of Errorsp.25214.3.1 Types of errorsp.25214.3.2 Storage of errorsp.25314.3.3 Error resetp.25314.3.4 Error code listp.254APPENDICESp.265Appendix 1 Functions Added or Changedp.265Appendix 1.1 Functions addedp.265Appendix 1.2 Functions changedp.265Appendix 2 Connection Examplesp.266Appendix 2.1 Example of connection with a servo amplifier manufactured by Mitsubishi Electric Corporationp.266Appendix 2.2 Example of connection with a servo amplifier manufactured by YASKAWA Electric Corporationp.267Appendix 3 Comparison of the QD73A1 and the AD70/A1SD70p.269Appendix 4 When Using GX Developerp.277Appendix 4.1 Operation of GX Developerp.277Appendix 5 Termsp.280Appendix 6 External Dimensionsp.282INDEXp.284REVISIONSp.288WARRANTYp.289
Page 1 of the Mitsubishi Electronics QD73A1 user manual — -QD73A1
Page 1 · click to enlarge
Page 1
Mitsubishi Electronics QD73A1 diagram (page 1)
Fig. 1

MELSEC-Q QD73A1 Positioning Module User's Manual

-QD73A1

Mitsubishi Electronics QD73A1 — -QD73A1 diagram (page 1)
Fig. 2
Mitsubishi Electronics QD73A1 — -QD73A1 diagram (page 1)
Fig. 3
Mitsubishi Electronics QD73A1 — -QD73A1 diagram (page 1)
Fig. 4
Page 2 of the Mitsubishi Electronics QD73A1 user manual
Page 2 · click to enlarge
Page 2
Page 2 of the Mitsubishi Electronics QD73A1 user manual
Page 3 of the Mitsubishi Electronics QD73A1 user manual — [Design Precautions]
Page 3 · click to enlarge
Page 3

SAFETY PRECAUTIONS

(Read these precautions before using this product.)

Before using this product, please read this manual and the relevant manuals carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this product only. For the safety precautions of the programmable controller system, refer to the user’s manual for the CPU module used.

In this manual, the safety precautions are classified into two levels: " WARNING" and " CAUTION".

WARNING

Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous conditions, resulting in minor or moderate injury or property damage.

CAUTION

Under some circumstances, failure to observe the precautions given under " CAUTION" may lead to serious consequences. Observe the precautions of both levels because they are important for personal and system safety.

Make sure that the end users read this manual and then keep the manual in a safe place for future reference.

[Design Precautions]

WARNING

  • Configure safety circuits external to the programmable controller to ensure that the entire system operates safely even when a fault occurs in the external power supply or the programmable controller. Failure to do so may result in an accident due to an incorrect output or malfunction. (1) When using a servo amplifier with Servo ON signal, connect the signal to the module. When using

a servo amplifier whose control cannot be stopped through Servo ON signal, satisfy the following. • Analog voltage must be 0V (motor stop) to power off the programmable controller. (2) Emergency stop circuits, protection circuits, and protective interlock circuits for conflicting

operations (such as forward/reverse rotations or upper/lower limit positioning) must be configured external to the programmable controller. (3) OPR (Original Point Return) is controlled by two kinds of data: OPR direction and OPR speed.

Deceleration starts when the near-point dog turns on. If an incorrect OPR direction is set, motion control may continue without deceleration. To prevent machine damage caused by this, configure an interlock circuit external to the programmable controller. ●Do not write any data to the "system area" of the buffer memory in the intelligent function module. Also, do not use any "use prohibited" signal as an output signal from the CPU module to the intelligent function module. Doing so may cause malfunction of the programmable controller system.

Page 4 of the Mitsubishi Electronics QD73A1 user manual — [Installation Precautions]
Page 4 · click to enlarge
Page 4

CAUTION

  • Do not install the connection cables for external I/O signals and for the drive unit together with the main circuit lines, power cables, or load circuit lines of a device other than the programmable controller. Keep a distance of 100mm or more between them. Failure to do so may result in malfunction due to noise, surges, and induction.

[Installation Precautions]

CAUTION

  • Use the programmable controller in an environment that meets the general specifications in the user’s manual for the CPU module used. Failure to do so may result in electric shock, fire, malfunction, or damage to or deterioration of the product.
  • To mount the module, while pressing the module mounting lever located in the lower part of the module, fully insert the module fixing projection(s) into the hole(s) in the base unit and press the module until it snaps into place. Incorrect mounting may cause malfunction, failure or drop of the module. When using the programmable controller in an environment of frequent vibrations, fix the module with a screw.
  • Tighten the screws within the specified torque range. Undertightening can cause drop of the screw, short circuit or malfunction. Overtightening can damage the screw and/or module, resulting in drop, short circuit, or malfunction.
  • Securely connect the drive unit connector and external device connector to the connector on the module. Poor contact may cause incorrect input or output.
  • Do not directly touch any conductive parts and electronic components of the module. Doing so can cause malfunction or failure of the module.
  • Shut off the external power supply (all phases) used in the system before mounting or removing the module. Failure to do so may result in damage to the product.
Page 5 of the Mitsubishi Electronics QD73A1 user manual — CAUTION
Page 5 · click to enlarge
Page 5

[Wiring Precautions]

WARNING

  • Shut off the external power supply (all phases) used in the system before installation and wiring. Failure to do so may result in electric shock or cause the module to fail or malfunction.
  • After installation and wiring, attach the included terminal cover to the module before turning it on for operation. Failure to do so may result in electric shock.

CAUTION

  • Check the rated voltage and terminal layout before wiring to the module, and connect the cables correctly. Connecting a power supply with a different voltage rating or incorrect wiring may cause a fire or failure.
  • Use applicable solderless terminals and tighten them within the specified torque range. If any spade solderless terminal is used, it may be disconnected when the terminal screw comes loose, resulting in failure.
  • Tighten the connector screws within the specified torque range. Undertightening can cause short circuit, fire, or malfunction. Overtightening can damage the screw and/or module, resulting in drop, short circuit, fire, or malfunction.
  • Connectors for external devices must be crimped with the tool specified by the manufacturer or must be correctly soldered. Incomplete connections may cause short circuit, fire, or malfunction.
  • Place the cables in a duct or clamp them. If not, dangling cable may swing or inadvertently be pulled, resulting in damage to the module or cables or malfunction due to poor contact.
  • When disconnecting the cable from the module, do not pull the cable by the cable part. For the cable with connector, hold the connector part of the cable. Pulling the cable connected to the module may result in malfunction or damage to the module or cable.
  • Prevent foreign matter such as dust or wire chips from entering the module. Such foreign matter can cause a fire, failure, or malfunction.
  • A protective film is attached to the top of the module to prevent foreign matter, such as wire chips, from entering the module during wiring. Do not remove the film during wiring. Remove it for heat dissipation before system operation.
Page 6 of the Mitsubishi Electronics QD73A1 user manual — [Disposal Precaution]
Page 6 · click to enlarge
Page 6

[Startup and Maintenance Precautions]

WARNING

  • Shut off the external power supply (all phases) used in the system before cleaning the module or retightening the connector screws. Failure to do so may result in electric shock.

CAUTION

  • Do not disassemble or modify the module. Doing so may cause failure, malfunction, injury, or a fire.
  • Shut off the external power supply (all phases) used in the system before mounting or removing a module. Failure to do so may cause the module to fail or malfunction.
  • After the first use of the product, do not mount/remove the module to/from the base unit, and the terminal block to/from the module more than 50 times (IEC 61131-2 compliant) respectively. Exceeding the limit may cause malfunction.
  • Before testing operation, set a low speed value for the speed limit parameter so that the operation can be stopped immediately upon occurrence of a hazardous condition.
  • Before handling the module, touch a conducting object such as a grounded metal to discharge the static electricity from the human body. Failure to do so may cause the module to fail or malfunction.

[Precaution during operation]

CAUTION

  • When changing data and operating status, and modifying program of the running programmable controller from an external device such as a personal computer connected to an intelligent function module, read relevant manuals carefully and ensure the safety before operation. Incorrect change or modification may cause system malfunction, damage to the machines, or accidents.

[Disposal Precaution]

CAUTION

  • When disposing of this product, treat it as industrial waste.
Page 7 of the Mitsubishi Electronics QD73A1 user manual — (1) Mitsubishi programmable controller ("the PRODUCT") shall be used in conditions;
Page 7 · click to enlarge
Page 7

CONDITIONS OF USE FOR THE PRODUCT

(1) Mitsubishi programmable controller ("the PRODUCT") shall be used in conditions;

i) where any problem, fault or failure occurring in the PRODUCT, if any, shall not lead to any major or serious accident; and ii) where the backup and fail-safe function are systematically or automatically provided outside of the PRODUCT for the case of any problem, fault or failure occurring in the PRODUCT.

(2) The PRODUCT has been designed and manufactured for the purpose of being used in general

industries. MITSUBISHI SHALL HAVE NO RESPONSIBILITY OR LIABILITY (INCLUDING, BUT NOT LIMITED TO ANY AND ALL RESPONSIBILITY OR LIABILITY BASED ON CONTRACT, WARRANTY, TORT, PRODUCT LIABILITY) FOR ANY INJURY OR DEATH TO PERSONS OR LOSS OR DAMAGE TO PROPERTY CAUSED BY the PRODUCT THAT ARE OPERATED OR USED IN APPLICATION NOT INTENDED OR EXCLUDED BY INSTRUCTIONS, PRECAUTIONS, OR WARNING CONTAINED IN MITSUBISHI'S USER, INSTRUCTION AND/OR SAFETY MANUALS, TECHNICAL BULLETINS AND GUIDELINES FOR the PRODUCT. ("Prohibited Application") Prohibited Applications include, but not limited to, the use of the PRODUCT in; • Nuclear Power Plants and any other power plants operated by Power companies, and/or any

other cases in which the public could be affected if any problem or fault occurs in the PRODUCT. • Railway companies or Public service purposes, and/or any other cases in which establishment of

a special quality assurance system is required by the Purchaser or End User. • Aircraft or Aerospace, Medical applications, Train equipment, transport equipment such as

Elevator and Escalator, Incineration and Fuel devices, Vehicles, Manned transportation, Equipment for Recreation and Amusement, and Safety devices, handling of Nuclear or Hazardous Materials or Chemicals, Mining and Drilling, and/or other applications where there is a significant risk of injury to the public or property.

Notwithstanding the above, restrictions Mitsubishi may in its sole discretion, authorize use of the PRODUCT in one or more of the Prohibited Applications, provided that the usage of the PRODUCT is limited only for the specific applications agreed to by Mitsubishi and provided further that no special quality assurance or fail-safe, redundant or other safety features which exceed the general specifications of the PRODUCTs are required. For details, please contact the Mitsubishi representative in your region.

Page 8 of the Mitsubishi Electronics QD73A1 user manual — Remark
Page 8 · click to enlarge
Page 8

INTRODUCTION

Thank you for purchasing the Mitsubishi MELSEC-Q series programmable controllers.

This manual describes the operating procedure, system configuration, parameter settings, functions, programming,

and troubleshooting of the QD73A1 positioning module (hereafter abbreviated as QD73A1).

Before using this product, please read this manual and the relevant manuals carefully and develop familiarity with the

functions and performance of the MELSEC-Q series programmable controller to handle the product correctly.

When applying the program examples introduced in this manual to an actual system, ensure the applicability and

confirm that it will not cause system control problems.

Relevant moduleQD73A1

Remark

  • Unless otherwise specified, this manual describes the program examples in which the I/O numbers of X/Y10 to X/Y2F are assigned for the QD73A1. For I/O number assignment, refer to the following manuals.

QnUCPU Users Manual (Function Explanation, Program Fundamentals)

Qn(H)/QnPH/QnPRHCPU User's Manual (Function Explanation, Program Fundamentals)

  • Operating procedures are explained using GX Works2. When using GX Developer, refer to the following.

Page 275, Appendix 4

Page 9 of the Mitsubishi Electronics QD73A1 user manual — (2) Additional measures
Page 9 · click to enlarge
Page 9

COMPLIANCE WITH EMC AND LOW VOLTAGE

DIRECTIVES

(1) Method of ensuring compliance

To ensure that Mitsubishi programmable controllers maintain EMC and Low Voltage Directives when incorporated

into other machinery or equipment, certain measures may be necessary. Please refer to one of the following

manuals.

  • QCPU User's Manual (Hardware Design, Maintenance and Inspection)
  • Safety Guidelines

(This manual is included with the CPU module or base unit.)

The CE mark on the side of the programmable controller indicates compliance with EMC and Low Voltage

Directives.

(2) Additional measures

To ensure that this product maintains EMC and Low Voltage Directives, please refer to Page 64, Section 4.6.1.

Page 10 of the Mitsubishi Electronics QD73A1 user manual — <SH-080373E, 13JU41>
Page 10 · click to enlarge
Page 10

RELEVANT MANUALS

(3) CPU module user's manual

Manual name

<manual number (model code)> Description

QCPU User's Manual (Hardware Design, Maintenance and

Specifications of the hardware (CPU modules, power supply modules,

base units, extension cables, and memory cards), system maintenance

<SH-080483ENG, 13JR73>

and inspection, troubleshooting, and error codes

QnUCPU Users Manual (Function Explanation, Program

<SH-080807ENG, 13JZ27>

Functions, methods, and devices for programming Qn(H)/QnPH/QnPRHCPU User's Manual (Function

<SH-080808ENG, 13JZ28>

(4) Operating manual

Manual name

<manual number (model code)> Description

GX Works2 Version1 Operating Manual (Common)

System configuration, parameter settings, and online operations (common

<SH-080779ENG, 13JU63>

to Simple project and Structured project) of GX Works2

GX Developer Version 8 Operating Manual

Operating methods of GX Developer, such as programming, printing,

<SH-080373E, 13JU41>

Show 4 more labels / short text on this page
Inspection) · Fundamentals) · Explanation, Program Fundamentals) · monitoring, and debugging
Page 11 of the Mitsubishi Electronics QD73A1 user manual — Memo
Page 11 · click to enlarge
Page 11

Memo

Page 12 of the Mitsubishi Electronics QD73A1 user manual — Table of Contents
Page 12 · Contents
Contents

Contents

SAFETY PRECAUTIONSp.3CONDITIONS OF USE FOR THE PRODUCTp.7INTRODUCTIONp.8COMPLIANCE WITH EMC AND LOW VOLTAGE DIRECTIVESp.9RELEVANT MANUALSp.10CONTENTSp.12MANUAL PAGE ORGANIZATIONp.16TERMSp.18PACKING LISTp.18CHAPTER 1 OVERVIEWp.191.1 Featuresp.201.2 Signal Transmission Between the QD73A1 and Othersp.21CHAPTER 2 SYSTEM CONFIGURATIONp.232.1 Applicable Systemsp.232.2 How to Check the Function Version and Serial Numberp.25CHAPTER 3 SPECIFICATIONSp.273.1 Performance Specificationsp.273.2 Number of Parameter Settingsp.283.3 List of Functionsp.293.4 I/O Signals from/to the CPU Modulep.323.4.1 I/O signal listp.323.4.2 Details of input signalsp.343.4.3 Details of output signalsp.393.5 Specifications of I/O Interfaces with External Devicesp.423.5.1 Electrical specifications of I/O signalsp.423.5.2 Signal layout for external device connectorsp.443.5.3 List of I/O signal detailsp.453.5.4 I/O interface internal circuitp.473.6 Memory Configuration and Usep.493.7 List of Buffer Memory Addressesp.50CHAPTER 4 SETTINGS AND PROCEDURE BEFORE OPERATIONp.564.1 Handling Precautionsp.564.2 Settings and Procedure Before Operationp.574.3 Part Namesp.584.4 LEDp.604.5 Zero/gain Adjustmentp.614.6 Wiringp.664.6.1 Wiring precautionsp.664.6.2 Precautions when connecting an encoderp.684.6.3 External device connectorsp.71CHAPTER 5 DATA USED FOR POSITIONINGp.755.1 Types of Datap.755.2 Positioning Parametersp.775.3 OPR Parametersp.815.4 Positioning Datap.845.5 Monitor Datap.875.6 Control Datap.91CHAPTER 6 VARIOUS SETTINGSp.1016.1 Adding a Modulep.1016.2 Switch Settingp.1026.2.1 Rotation direction settingp.1036.2.2 Accumulated pulse settingp.1046.2.3 Multiplication settingp.1066.2.4 OPR direction settingp.1066.2.5 OPR method settingp.1066.2.6 Encoder I/F settingp.1076.2.7 Analog voltage resolution settingp.1076.2.8 Feedback pulse addition/subtraction settingp.1086.2.9 Deviation counter clear settingp.1096.3 Parameter Settingp.1106.4 Positioning Data Settingp.1116.5 Auto Refreshp.112CHAPTER 7 PROGRAMMINGp.1137.1 Precautions on Programmingp.1137.2 Programs for Positioningp.1167.3 When Using the Module in a Standard System Configurationp.1177.3.1 Parameter setting programp.1197.3.2 OPR programp.1217.3.3 Major positioning control programp.1277.3.4 Fixed-feed operation programp.1357.3.5 JOG operation programp.1377.3.6 Control change programp.1397.3.7 Stop program during positioningp.1437.4 When Using the Module in a Remote I/O Networkp.1447.4.1 Parameter setting programp.1517.4.2 OPR programp.1537.4.3 Major positioning control programp.1597.4.4 Fixed-feed operation programp.1697.4.5 JOG operation programp.1727.4.6 Control change programp.1747.4.7 Stop program during positioningp.179CHAPTER 8 OPR CONTROLp.1808.1 Overview of OPR Controlp.1808.2 Near-point Dog Methodp.1818.3 Count Methodp.1838.4 Operation Timing and Processing Time of OPR Controlp.1858.5 OPR Parameter Settingp.186CHAPTER 9 MAJOR POSITIONING CONTROLp.1879.1 Overview of Major Positioning Controlp.1879.2 Data Required for Major Positioning Controlp.1889.3 Relation Between Each Control and Positioning Datap.1899.4 Specifying a Positioning Addressp.1909.5 Checking the Current Valuep.1919.6 Details of Major Positioning Controlp.1929.6.1 Position control modep.1939.6.2 Speed-position control switch modep.1979.7 Operation Timing and Processing Time of Major Positioning Controlp.201CHAPTER 10 JOG OPERATIONp.20210.1 Operation of JOG Operationp.20310.2 Operation Timing and Processing Time of JOG Operationp.20810.3 Data Setting for JOG Operationp.209CHAPTER 11 CONTROL SUB FUNCTIONSp.21011.1 Electronic Gear Functionp.21111.2 Speed Limit Functionp.21311.3 Stroke Limit Functionp.21511.4 Upper Limit Switch (FLS)/Lower Limit Switch (RLS) Functionp.21711.5 Current Value Change Functionp.21911.6 Speed Change Functionp.22011.7 Deviation Counter Clear Functionp.22211.8 In-position Functionp.22311.9 Accumulated Pulse Error Detection Functionp.22511.9.1 Measuring and saving the reference value in the flash ROMp.22711.9.2 Setting the accumulated pulse error detection functionp.228CHAPTER 12 STOPPING AND RESTARTING CONTROLp.23212.1 Stopping Controlp.23212.2 Restarting the Speed-position Control Switch Modep.236CHAPTER 13 COMMON FUNCTIONSp.23813.1 Module Status Monitor Functionp.23813.2 Error History Functionp.24013.3 Module Error Collection Functionp.24113.4 Error Clear Functionp.242CHAPTER 14 TROUBLESHOOTINGp.24314.1 Checking an Error on GX Works2p.24314.2 Troubleshootingp.24714.2.1 Troubleshooting procedurep.24714.2.2 When the motor does not stopp.24814.2.3 When positioning cannot be executedp.24814.2.4 When a positioning error occursp.24914.2.5 When the positioning speed is different from the specified speedp.25014.2.6 When operation stops abnormally during positioningp.25014.2.7 OPR errorp.25114.3 Details of Errorsp.25214.3.1 Types of errorsp.25214.3.2 Storage of errorsp.25314.3.3 Error resetp.25314.3.4 Error code listp.254APPENDICESp.265Appendix 1 Functions Added or Changedp.265Appendix 1.1 Functions addedp.265Appendix 1.2 Functions changedp.265Appendix 2 Connection Examplesp.266Appendix 2.1 Example of connection with a servo amplifier manufactured by Mitsubishi Electric Corporationp.266Appendix 2.2 Example of connection with a servo amplifier manufactured by YASKAWA Electric Corporationp.267Appendix 3 Comparison of the QD73A1 and the AD70/A1SD70p.269Appendix 4 When Using GX Developerp.277Appendix 4.1 Operation of GX Developerp.277Appendix 5 Termsp.280Appendix 6 External Dimensionsp.282INDEXp.284REVISIONSp.288WARRANTYp.289
Page 16 of the Mitsubishi Electronics QD73A1 user manual — MANUAL PAGE ORGANIZATION
Page 16 · click to enlarge
Page 16

MANUAL PAGE ORGANIZATION

In this manual, pages are organized and the symbols are used as shown below.

The following illustration is for explanation purpose only, and should not be referred to as an actual documentation.

Mitsubishi Electronics QD73A1 — MANUAL PAGE ORGANIZATION diagram (page 16)
Fig. 5

[ ] is used for items in the menu bar and the project window.

*1 The mouse operation example is provided below.

Mitsubishi Electronics QD73A1 — MANUAL PAGE ORGANIZATION diagram (page 16)
Fig. 6

[Online] [Write to PLC...] Select [Online] on the menu bar, and then select [Write to PLC...].

A window selected in the view selection area is displayed.

Select [Project] from the view selection area to open the Project window.

In the Project window, expand [Parameter] and select [PLC Parameter].

Page 17 of the Mitsubishi Electronics QD73A1 user manual — MANUAL PAGE ORGANIZATION
Page 17 · click to enlarge
Page 17

The following symbols are used to represent buffer memory areas in this manual. Serial numbers fit in "*".

Symbol indicating positioning parameter and OPR parameter item

Pr.*

Symbol indicating positioning data item

Da.*

Md.*

Symbol indicating monitor data item

Cd.*

Symbol indicating control data item

Symbol Description

Page 18 of the Mitsubishi Electronics QD73A1 user manual — Model Product Quantity
Page 18 · click to enlarge
Page 18

TERMS

Unless otherwise specified, this manual uses the following terms.

Term Description

QD73A1 The abbreviation for the QD73A1 positioning module

QCPU Another term for the MELSEC-Q series CPU module

Redundant CPU A generic term for the Q12PRHCPU and Q25PRHCPU

External input The abbreviation for input from connectors for external devices

External output The abbreviation for output to connectors for external devices

Programming tool Generic term for GX Works2 and GX Developer

GX Works2 The product name of the software package for the MELSEC programmable

Buffer memory The memory of an intelligent function module used to store data (such as setting

values and monitored values) for communication with a CPU module

For terms related to positioning, refer to the following.

Page 278, Appendix 5

PACKING LIST

The product package contains the following.

Model Product Quantity

QD73A1 QD73A1 positioning module 1

QD73A1-U-HW Before Using the Product 1

controllers GX Developer

Page 19 of the Mitsubishi Electronics QD73A1 user manual — M
Page 19 · click to enlarge
Page 19

CHAPTER 1 OVERVIEW

CHAPTER 1 OVERVIEW

The QD73A1 possesses a deviation counter and D/A converter inside as in the following figure.

M

PLG

Parameter data Positioning data OPR parameters

Feedback pulses from the pulse generator (PLG) may be input to the QD73A1 via the drive unit*1 or directly*2 depending on the servomotor to be used. Check which method applies in the manual for the servomotor or drive unit to be used.

A system with the QD73A1 operates as follows.

Once a command pulse train for positioning is output, pulses are accumulated in the deviation counter. The

integrated value of pulses (accumulated pulses) is converted into DC analog voltage by a D/A converter, then

turns into a speed command to a servomotor. The speed command from a drive unit starts servomotor rotation.

Once the servomotor starts rotating, feedback pulses that are proportional to the number of rotations are

generated by a pulse generator (PLG) attached to the servomotor. The generated feedback pulses are

subtracted from the accumulated pulses in the deviation counter. The deviation counter continues to rotate the

servomotor, maintaining a constant amount of accumulated pulse.

Stop Once the command pulse output from the QD73A1 stops, the accumulated pulses in the deviation counter

decrease, so does the speed. When there is no more accumulated pulse, the servomotor stops.

The rotation speed of a servomotor is proportional to command pulse frequency, while the rotation degree of the

servomotor is proportional to the output command pulse amount. By setting feed per pulse beforehand, analog voltage

that is proportional to the number of pulses in a pulse train is output, and a workpiece can be moved to the set position.

Show 31 more labels / short text on this page
CPU module · Positioning module QD73A1 · Drive unit Servomotor · Command · Analog · Speed command · pulses · Electronic · Deviation · D/A converter · voltage · Servo amplifier · gear · counter · data Sequence · Setting · Feedback pulse · addition/ subtraction setting · Interface · program · Current · value · Multiplication · Feedback pulses · *1 · *1 · Data writing/reading · *2 · Feedback pulses · Start · Operation
Page 20 of the Mitsubishi Electronics QD73A1 user manual — (6) Easy setting with GX works2
Page 20 · click to enlarge
Page 20

1.1 Features

(1) Analog output type that possesses a deviation counter and D/A converter

inside

This module converts command pulse for positioning into analog voltage inside, then outputs a speed command

to a servo amplifier.

(2) Compatible with analog input servo amplifiers

A servo amplifier does not require an extra module to convert pulse input into analog voltage; a standard servo

amplifier can be used.

(3) Servomotor control using a high-resolution encoder

This module handles up to 1Mpulse/s of pulse input from an encoder. Servomotor control that uses high-speed

input pulse signals from a high-resolution encoder improves the accuracy of positioning.

(4) Four types of positioning method

The following control can be executed.

  • Position control mode: positioning control and two-phase trapezoidal positioning control
  • Speed-position control switch mode: speed-position control switchover and speed control

(5) Zero/gain adjustment through a sequence program

Zero/gain adjustment can be performed through a sequence program. Therefore, the adjustment can be

performed without using a switch or checking a LED, saving man-hour.

(Note that zero/gain adjustment can also be performed using switches on the front of the QD73A1.)

(6) Easy setting with GX works2

Sequence programming is reduced since initial settings and the auto refresh setting can be configured on the

screen. In addition, the setting status and operating status of the module can be checked easily.

Page 21 of the Mitsubishi Electronics QD73A1 user manual — X2D
Page 21 · click to enlarge
Page 21

CHAPTER 1 OVERVIEW

1.2 Signal Transmission Between the QD73A1 and Others

The following figure shows signal transmission between the QD73A1 and a CPU module, and a drive unit.

QD73A1

Y2D

Near-point dog signal (DOG)

Upper limit signal (FLS)

Y20

Lower limit signal (RLS) Speed-position switching command signal

OPR start complete signal

(CHANGE)

Positioning start complete signal

Phase-Z pulse (Zero signal)

PLG

Y2C

Speed-position switching enable signal

Y24, Y25

Speed-position mode restart signal

Y26

Servo READY signal (READY)

Y27

Servo ON signal (SVON)

Y28

Y29

X1A

1.2 Signal Transmission Between the QD73A1 and Others

Y2A

X1D

Upper limit signal/Lower limit signal

X1E, X1F

X1B

WDT error, H/W error signal

writing request signal Zero/gain adjustment data

Y1A

X2A

Zero/gain adjustment change request signal

Y1B

Zero/gain adjustment change complete flag

X2B

Y1C

Set value change request signal

Set value change complete flag

Operating status of the speed-position

X2D

Show 41 more labels / short text on this page
CPU module · PLC READY signal · Stop signal (STOP) · QD73A1 READY signal · OPR request signal · External · OPR start signal · control · signals · OPR complete signal · Positioning start signal · Y21 to Y23 · X21 to X23 · BUSY signal · External interface · Phase-A pulse · Positioning complete signal · Phase-B pulse · JOG start signal · Stop signal · Error detection signal · Drive unit · Error reset signal · Overflow signal · Analog voltage · Overflow reset signal · Interface with · Underflow signal · the CPU · module · Underflow reset signal · In-position signal · Excessive error signal · Near-point dog signal · External stop signal · Servo READY signal · Synchronization flag · Zero/gain adjustment data · writing complete flag · control switch mode · Data writing/reading
Page 22 of the Mitsubishi Electronics QD73A1 user manual — (2) Between the drive unit and the QD73A1
Page 22 · click to enlarge
Page 22

(1) Between the CPU module and the QD73A1

The CPU module and the QD73A1 transmit control signals and data to each other through the base unit.

Transmitted item Description Reference

Control signal Signals that indicate the QD73A1's status or

are related to commands are transmitted. Page 30, Section 3.4

Data is written to or read from the buffer

memory in the QD73A1 by application

Page 73, CHAPTER 5

instructions of the CPU module.

(2) Between the drive unit and the QD73A1

Control signals are transmitted between the drive unit and the QD73A1, and speed commands (analog voltage)

are output from the QD73A1 to the drive unit.

For details, refer to the following.

Page 40, Section 3.5

Data

Page 23 of the Mitsubishi Electronics QD73A1 user manual — (3) Online module change
Page 23 · click to enlarge
Page 23

CHAPTER 2 SYSTEM CONFIGURATION

CHAPTER 2 SYSTEM CONFIGURATION

This chapter describes the system configuration of the QD73A1.

2.1 Applicable Systems

This section describes applicable systems.

(1) Applicable modules and base units, and number of mountable modules

For the applicable CPU modules and base units, and the number of mountable modules, refer to the user’s

manual for the CPU module used.

  • The power supply capacity may become insufficient depending on the combination with other modules or the

number of mounted modules.

Select the power supply capacity according to the modules to be used.

If the power supply capacity is insufficient, change the combination of the modules.

  • Mount the modules within the number of I/O points range of the CPU module.

Modules can be mounted on any slot within the number of available slots.

(a) When mounted on MELSECNET/H remote I/O station

For an applicable MELSECNET/H remote I/O station and base units, and the number of mountable modules,

refer to the Q Corresponding MELSECNET/H Network System Reference Manual (Remote I/O network).

2.1 Applicable Systems

(2) Multiple CPU system

The function version of the first released QD73A1 is B, and the module supports multiple CPU systems.

When using the QD73A1 in a multiple CPU system, refer to the following.

QCPU User's Manual (Multiple CPU System)

(a) Intelligent function module parameters

Write intelligent function module parameters to only the control CPU of the QD73A1.

(3) Online module change

The QD73A1 does not support online module change.

Page 24 of the Mitsubishi Electronics QD73A1 user manual — Q10UDEH/Q20UDEHCPU
Page 24 · click to enlarge
Page 24

(4) Applicable software packages

The following table lists systems that use the QD73A1 and applicable software packages.

A programming tool is required to use the QD73A1.

GX Developer*1 GX Works2

Single CPU system Version 7 or later

Q00J/Q00/Q01CPU

Multiple CPU system Version 8 or later

Single CPU system Version 4 or later

Q02/Q02H/Q06H/Q12H/Q25HCPU

Multiple CPU system Version 6 or later

Q02PH/Q06PHCPU

Version 8.68W or later Multiple CPU system

Q12PH/Q25PHCPU

Version 7.10L or later Multiple CPU system

Q12PRH/Q25PRHCPU Redundant system Version 8.45X or later

Q00UJ/Q00U/Q01UCPU

Version 8.76E or later Multiple CPU system

Refer to the GX Works2 Version 1 Operating Manual

Q02U/Q03UD/Q04UDH/Q06UDHCPU

Version 8.48A or later Multiple CPU system

(Common).

Q10UDH/Q20UDHCPU

Version 8.76E or later Multiple CPU system

Q13UDH/Q26UDHCPU

Version 8.62Q or later Multiple CPU system

Q03UDE/Q04UDEH/Q06UDEH/Q13UDEH/Q26 UDEHCPU

Version 8.68W or later Multiple CPU system

Q10UDEH/Q20UDEHCPU

Version 8.76E or later Multiple CPU system

CPU modules other than the above

N/A Multiple CPU system

When mounted on a MELSECNET/H remote I/O station Version 6 or later

*1 When using GX Developer, configure the initial settings and auto refresh settings with the sequence program.

PROGRAMMING ( Page 111, CHAPTER 7)

Show 11 more labels / short text on this page
Software version · Item · Single CPU system · Single CPU system · Single CPU system · Single CPU system · Single CPU system · Single CPU system · Single CPU system · Single CPU system · Single CPU system
Page 25 of the Mitsubishi Electronics QD73A1 user manual — (2) Checking on the front part (bottom part) of the module
Page 25 · click to enlarge
Page 25

CHAPTER 2 SYSTEM CONFIGURATION

2.2 How to Check the Function Version and Serial Number

Mitsubishi Electronics QD73A1 — CHAPTER 2 SYSTEM CONFIGURATION diagram (page 25)
Fig. 7

The function version and serial number of the QD73A1 can be checked on the rating plate, front part of the module, or

(1) Checking on the rating plate

The rating plate is on the side of the QD73A1.

Mitsubishi Electronics QD73A1 — (1) Checking on the rating plate diagram (page 25)
Fig. 8 · (1) Checking on the rating plate

(2) Checking on the front part (bottom part) of the module

The function version and serial number on the rating plate are also shown on the front part (bottom part) of the

2.2 How to Check the Function Version and Serial Number

module.

Page 26 of the Mitsubishi Electronics QD73A1 user manual — (3) Checking on the system monitor
Page 26 · click to enlarge
Page 26

(3) Checking on the system monitor

The function version and serial number can be checked on the "Product Information List" window.

[Diagnostics] [System Monitor...] button

Mitsubishi Electronics QD73A1 — (3) Checking on the system monitor diagram (page 26)
Fig. 9 · (3) Checking on the system monitor
  • The serial number displayed on the product information list of a programming tool may differ from that on the rating plate and on the front part of the module.
  • The serial number on the rating plate and front part of the module indicates the management information of the

product. • The serial number displayed on the product information list of a programming tool indicates the function

information of the product. The function information of the product is updated when a new function is added.

Page 27 of the Mitsubishi Electronics QD73A1 user manual — Item Specifications
Page 27 · click to enlarge
Page 27

CHAPTER 3 SPECIFICATIONS

CHAPTER 3 SPECIFICATIONS

This chapter describes performance specifications, I/O signals from/to the CPU module, and buffer memory

specifications of the QD73A1.

For general specifications of the QD73A1, refer to the following.

QCPU User's Manual (Hardware Design, Maintenance and Inspection)

3.1 Performance Specifications

The following table lists performance specifications of the QD73A1.

Item Specifications

Number of occupied I/O points 48 points (I/O assignment: empty 16 points and intelligent 32 points)

Number of control axes 1 axis

Setting method Sequence program

Mode Position control mode

Speed-position control switch mode

Position control modeSelectable from absolute system or incremental
Speed-position control switch modeIncremental system

Position command -2147483648 to 2147483647 (pulse) (signed 32-bit binary)

Speed command 1 to 4000000 (pulse/s)

Acceleration Automatic trapezoidal acceleration/deceleration

Acceleration time2 to 9999 (ms)

3.1 Performance Specifications

Deceleration time2 to 9999 (ms)

In-position range 1 to 20479 (pulse)

Error correction function None

Speed command output 0 to ±10VDC (Adjustable to set in the range of ±5 to ±10VDC)

Open collector200kpulse/s
TTL200kpulse/s
Differential output1Mpulse/s

Connectable encoder type Open collector, TTL, or differential output

Multiplication setting The number of input feedback pulses can be multiplied by 4, 2, 1, or 1/2.

OPR control With OP address change

An OPR method and OPR direction can be set with the switch setting.

JOG operation JOG operation can be started by inputting a JOG start signal.

Internal current consumption (5VDC) 0.52A

External supply voltage/current terminal block No external power supply

External dimensions 98(H)mm × 55.2(W)mm × 90(D)mm

Weight 0.20kg

Absolute system1.2ms (same for two-phase trapezoidal positioning)
Incremental system1.2ms (same for two-phase trapezoidal positioning)
JOG operation1.2ms

(from a start request to analog output start)

OPR (near-point dog method)1.2ms
OPR (count method)1.2ms
Show 13 more labels / short text on this page
Capacity 1 data · Positioning data · System · system · Positioning · Automatic · acceleration/deceleration time · Backlash compensation None · Pulse frequency · Positioning feedback · pulse input · M function None · Starting time
Page 28 of the Mitsubishi Electronics QD73A1 user manual — No. Description
Page 28 · click to enlarge
Page 28

3.2 Number of Parameter Settings

Set initial settings and auto refresh settings of the QD73A1 so that the number of parameters, including those of other

intelligent function modules, does not exceed the number of parameters that can be set in the CPU module.

For the maximum number of parameters that can be set in the CPU module, refer to the following.

QCPU User's Manual (Hardware Design, Maintenance and Inspection)

(1) Number of QD73A1 parameters

For a QD73A1, the following number of parameters can be set.

Initial setting Auto refresh setting

(2) Checking method

The maximum number of parameter settings and the number of parameter settings set for the intelligent function

module can be checked on the following.

Project window [Intelligent Function Module] Right-click

[Intelligent Function Module Parameter List...]

Mitsubishi Electronics QD73A1 — Initial setting Auto refresh setting diagram (page 28)
Fig. 10 · Initial setting Auto refresh setting
Mitsubishi Electronics QD73A1 — Initial setting Auto refresh setting diagram (page 28)
Fig. 11 · Initial setting Auto refresh setting
1. 2) 3) 4)

No. Description

1. The total number of parameters in initial settings checked on the window
2. The maximum number of parameter settings in initial settings
3. The total number of parameters in the auto refresh setting checked on the window
4. The maximum number of parameter settings in the auto refresh setting
Page 29 of the Mitsubishi Electronics QD73A1 user manual — Item Description Reference
Page 29 · click to enlarge
Page 29

CHAPTER 3 SPECIFICATIONS

3.3 List of Functions

This section introduces the functions of the QD73A1.

(1) Main functions

Major positioning functions are as follows.

Item Description Reference

A workpiece is returned to an original point following an OPR start

command, and the current value is corrected as an OP address after the

CHAPTER 8

completion of OPR.

Positioning is executed from the current position to a specified position at

Section 9.6.1

a specified speed.

Positioning is executed to the address specified with " Positioning

Da.2

address P1" at " Positioning speed V1", then to the address

Da.3

Section 9.6.1

specified with " Positioning address P2" at " Positioning

Da.4 Da.5

speed V2" by one positioning start signal.

Operation starts according to the positioning speed set beforehand by

one positioning start signal, then the operation switches to position

control by Speed-position switching command signal (CHANGE).

If the operation stopped by Stop signal after the input of Speed-position

switching command signal (CHANGE), the positioning can be continued

Section 9.6.2

by requesting a restart.

In addition, the positioning address (movement amount) can be changed

if it is before the input of Speed-position switching command signal

(CHANGE).

3.3 List of Functions

Positioning is executed in the specified direction at specified speed while

a JOG operation command is on. Turning on the signal starts operation

at a specified speed and speed control operation can be continued until a

CHAPTER 10

stop signal is input.

(2) Sub functions

Sub functions compensate or limit control, or add functions at the execution of major positioning functions.

Item Description Reference

Electronic gear function This function controls moving distance and speed by

multiplying command pulse output of the QD73A1. Page 209, Section 11.1

This function limits command speed to the value set in

Page 211, Section 11.2

" Speed limit value".

Pr.5

This function controls operation not to execute positioning

when a command that moves the workpiece outside the

Page 213, Section 11.3

specified stroke limit range is given.

This function decelerates and stops operation according to the

detection on limit switches placed at the upper and lower

Page 215, Section 11.4

stroke limits.

Show 33 more labels / short text on this page
Page 178, · OPR control · Page 191, · Positioning · control · Position · (1) · control · Two-phase · mode · Page 192, · trapezoidal · positioning · (2) · control · Major · positioning · control · Speed-position control switch · Page 195, · mode · Page 200, · JOG operation · Functions to · compensate · control · Speed limit function · Functions to limit · Stroke limit function · control · Upper limit switch · (FLS)/lower limit switch · (RLS) function
Page 30 of the Mitsubishi Electronics QD73A1 user manual — Item Description Reference
Page 30 · click to enlarge
Page 30

Item Description Reference

This function changes the value set in " Current feed

Md.1

Page 217, Section 11.5

value" to a specified value.

Speed change function This function changes speed during major positioning control

or JOG operation. Page 218, Section 11.6

This function clears the accumulated pulses in the deviation

counter. When the servomotor power was turned off due to an

emergency stop during positioning, clearing the accumulated

Page 220, Section 11.7

pulses in the deviation counter prevents servomotor rotation

at power recovery.

This function turns on In-position signal (X16) while the

accumulated pulse amount in the deviation counter is within

the specified in-position range (1 to 20479pulse). In-position

Page 221, Section 11.8

signal (X16) can be used as the signal right before positioning

completion.

Multiplication setting This function multiplies the feedback pulse frequency from the

pulse generator by 4, 2, 1, or 1/2. Page 104, Section 6.2.3

This function outputs an alert and immediately stops the

positioning when the accumulated pulses reached the amount

specified by the user before the pulses exceed the amount set

Page 223, Section 11.9

in "Accumulated pulse setting" in the switch setting and an

excessive error occurs.

(3) Common functions

Common functions can be used regardless of control method when necessary.

Item Description Reference

Zero/gain adjustment This function adjusts analog output voltage. Page 59, Section 4.5

This function monitors the module information, switch setting

information, and external I/O signal information. The module's

Module status monitor function

detailed information can be displayed on the system monitor of GX

Works2.

Error history function This function monitors the QD73A1's error history stored in the

buffer memory.

This function reports errors that occurred in the QD73A1 to the CPU

Module error collection function

module. The error information is held in the CPU module memory as

a module error history.

Error clear function This function allows the user to clear errors on the system monitor. Page 240, Section

Show 14 more labels / short text on this page
Current value change · function · Functions to · change control · details · Deviation counter clear · function · In-position function · Other functions · Accumulated pulse error · detection function · Page 236, Section · Page 238, Section · Page 239, Section
Page 31 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 3 SPECIFICATIONS
Page 31 · click to enlarge
Page 31

CHAPTER 3 SPECIFICATIONS

(4) Combination of main function and sub function

Mitsubishi Electronics QD73A1 — CHAPTER 3 SPECIFICATIONS diagram (page 31)
Fig. 12

: Always used together, : Can be used together, ×: Cannot be used together

Page 32 of the Mitsubishi Electronics QD73A1 user manual — Device No. Signal name Device No. Signal name
Page 32 · click to enlarge
Page 32

3.4 I/O Signals from/to the CPU Module

This section describes I/O signals of the QD73A1.

3.4.1 I/O signal list

This section describes I/O signal assignment and use of each signal.

The first half of the I/O assignment is empty 16 points, and the second half is intelligent 32 points. When the module is

mounted on the slot No.0 and 1 of a main base unit, the device No.Xn0 becomes X10. Although, when the slot No.0 is

set as empty 0 point in the I/O assignment setting of GX Works2, the device No.Xn0 becomes X0 (n=0).

Device numbers used in this manual are for the case when the QD73A1 is mounted on the slot No.0 and 1 and when

the slot No.0 is empty 16 points.

(1) Input signal list

Input signal (CPU module QD73A1) Input signal (CPU module QD73A1)

Device No. Signal name Device No. Signal name

X10 WDT error, H/W error signal X20 OPR start complete signal

X11 QD73A1 READY signal X21 Absolute positioning start complete signal

X12 OPR request signal X22 Forward start complete signal

X13 OPR complete signal X23 Reverse start complete signal

X14 BUSY signal X24 Synchronization flag

X15 Positioning complete signal X25

X16 In-position signal X26

X17 Excessive error signal X27

X18 Error detection signal X28

X19 Overflow signal X29

X1A Underflow signal X2A Zero/gain adjustment data writing complete

X1B Servo READY signal X2B Zero/gain adjustment change complete flag

X1C Near-point dog signal X2C Set value change complete flag

X1D External stop signal X2D Operating status of the speed-position

X1E Upper limit signal X2E

Use prohibited X1F Lower limit signal X2F

If a "Use prohibited" area is turned on/off through a sequence program, the QD73A1's function cannot be guaranteed.

Use prohibited · flag · control switch mode

Page 33 of the Mitsubishi Electronics QD73A1 user manual — Y1E Y2E
Page 33 · click to enlarge
Page 33

CHAPTER 3 SPECIFICATIONS

(2) Output signal list

Output signal (CPU module QD73A1) Output signal (CPU module QD73A1)

Device No. Signal name Device No. Signal name

Y10

Y20 OPR start signal

Y11 Y21 Absolute positioning start signal

Y12 Y22 Forward start signal

Y13 Y23 Reverse start signal

Y14 Y24 Forward JOG start signal

Y15 Y25 Reverse JOG start signal

Y16 Y26 Speed-position mode restart signal

Y17 Y27 Stop signal

Y18 Y28 Error reset signal

Y19 Y29 Overflow reset signal

Y1A Zero/gain adjustment data writing request

signal Y2A Underflow reset signal

Y1B Zero/gain adjustment change request

signal Y2B Use prohibited

Y1C Set value change request signal Y2C Speed-position switching enable signal

Y1D

Y2D PLC READY signal

Y1E Y2E

Use prohibited Y1F Y2F

If a "Use prohibited" area is turned on/off through a sequence program, the QD73A1's function cannot be guaranteed.

3.4 I/O Signals from/to the CPU Module 3.4.1 I/O signal list

Use prohibited · Use prohibited

Page 34 of the Mitsubishi Electronics QD73A1 user manual — (5) BUSY signal (X14)
Page 34 · click to enlarge
Page 34

3.4.2 Details of input signals

(1) WDT error, H/W error signal (X10)

This signal turns on when a watchdog timer error is detected through the self-diagnostic function of the QD73A1.

In this case, Servo ON signal (SVON) turns off and analog output becomes 0.

(2) QD73A1 READY signal (X11)

When PLC READY signal (Y2D) is turned on through a sequence program, fixed parameters are checked and

this signal turns on.

When PLC READY signal (Y2D) is turned off, this signal turns off.

ON

PLC READY signal (Y2D)

OFF

ON

QD73A1 READY signal (X11)

OFF

Executed by the QD73A1

Use this signal as an interlock in sequence programs.

(3) OPR request signal (X12)

This signal turns on at any of the following timing.

  • When the power is turned on
  • When the CPU module was reset
  • When OPR starts
  • When Servo READY signal (READY) turns off while BUSY signal (X14) is on
  • When Servo READY signal (READY) turns off while BUSY signal (X14) is off

(only when "0: Clear the deviation counter when the servo ready signal is OFF." is selected for "Deviation

counter clear setting" in the switch setting)

This signal turns off when OPR is completed.

When PLC READY signal (Y2D) is turned on (rising edge), this signal does not turn on.

(4) OPR complete signal (X13)

This signal turns on when OPR is completed.

This signal does not turn on if operation stopped during OPR.

This signal turns off when JOG operation or major positioning control is started.

In the count method, this signal turns off when OPR starts.

This signal turns off when Servo READY signal (READY) turns off (only when "0: Clear the deviation counter

when the servo ready signal is OFF." is selected for "Deviation counter clear setting" in the switch setting)

(5) BUSY signal (X14)

This signal turns on when major positioning control, JOG operation, or OPR starts.

This signal turns off when command pulse output is completed.

If positioning is started while BUSY signal (X14) is on, the error "BUSY signal ON at start" (error code: 81) occurs.

Page 35 of the Mitsubishi Electronics QD73A1 user manual — OFF
Page 35 · click to enlarge
Page 35

CHAPTER 3 SPECIFICATIONS

(6) Positioning complete signal (X15)

This signal turns on when major positioning control is completed (completion of command pulse output).

This signal turns off when the next positioning (major positioning control, OPR, or JOG operation) starts.

If major positioning control was cancelled during its operation, this signal does not turn on.

For the operation in case of cancellation of major positioning control, refer to the following.

Page 230, Section 12.1

(7) In-position signal (X16)

This signal turns on while the accumulated pulse amount in the deviation counter is within the set range of

" In-position range" (1 to ±20479) after deceleration started.

Pr.8

This signal turns off when positioning starts.

In-position set values Accumulated pulses

ON

(X16)

OFF

A A

A: In-position range

Accumulated pulse amount are checked being compared with " In-position range" at the following timing.

Pr.8

  • When the power is turned on
  • When automatic deceleration starts in positioning, and thereafter
  • When a JOG start signal was turned off and deceleration starts in JOG operation, and thereafter

3.4 I/O Signals from/to the CPU Module 3.4.2 Details of input signals

  • When the near-point dog turned on and deceleration to the creep speed starts in OPR, and thereafter

(8) Excessive error signal (X17)

This signal turns on when accumulated pulse amount exceeds the accumulated pulse setting range.

In this case, the QD73A1's status is as follows.

  • Analog output voltage: 0V
  • Accumulated pulse: Reset to 0
  • Servo ON signal (SVON): OFF
  • Actual current value = Current feed value

Md.2 Md.1

When PLC READY signal (Y2D) is turned on, this signal turns off.

ON

Excessive error signal (X17)

OFF

ON

PLC READY signal (Y2D)

OFF

Executed by the QD73A1

Even if this signal turns on, Error detection signal (X18) does not turn on.

For the accumulated pulse setting range, refer to the following.

Page 102, Section 6.2.2

t · In-position signal

Page 36 of the Mitsubishi Electronics QD73A1 user manual — (16)Lower limit signal (X1F)
Page 36 · click to enlarge
Page 36

(9) Error detection signal (X18)

When a major or minor error occurs, the corresponding error code is stored in the buffer memory, and this signal

turns on.

When Error reset signal (Y28) is turned on, this signal turns off.

ON

Error detection signal (X18)

OFF

ON

Error reset signal (Y28)

OFF

Executed by the QD73A1

(10)Overflow signal (X19)

This signal turns on when " Current feed value" exceeds 2147483647.

Md.1

When Overflow reset signal (Y29) is turned on, this signal turns off.

ON

OFF

ON

Overflow reset signal (Y29)

OFF

Executed by the QD73A1

In case of an overflow, " Current feed value" changes as follows: 2147483647 -2147483648

Md.1

(11)Underflow signal (X1A)

This signal turns on when " Current feed value" becomes less than -2147483648.

Md.1

When Underflow reset signal (Y2A) is turned on, this signal turns off.

ON

OFF

ON

Underflow reset signal (Y2A)

OFF

Executed by the QD73A1

In case of an underflow, " Current feed value" changes as follows: -2147483648 2147483647

Md.1

(12)Servo READY signal (X1B)

This signal indicates the on/off status of Servo READY signal (READY).

(13)Near-point dog signal (X1C)

This signal indicates the on/off status of Near-point dog signal (DOG).

(14)External stop signal (X1D)

This signal indicates the on/off status of Stop signal (STOP).

(15)Upper limit signal (X1E)

This signal indicates the on/off status of Upper limit signal (FLS).

(16)Lower limit signal (X1F)

This signal indicates the on/off status of Lower limit signal (RLS).

Overflow signal (X19) · Underflow signal (X1A)

Page 37 of the Mitsubishi Electronics QD73A1 user manual — OFF
Page 37 · click to enlarge
Page 37

CHAPTER 3 SPECIFICATIONS

(17)OPR start complete signal (X20)

This signal turns on when OPR process starts after OPR start signal (Y20) was turned on.

When OPR start signal (Y20) is turned off after the start of OPR, this signal turns off.

(18)Absolute positioning start complete signal (X21)

This signal turns on when positioning process starts after Absolute positioning start signal (Y21) was turned on.

When Absolute positioning start signal (Y21) is turned off after the start of the positioning, this signal turns off.

(19)Forward start complete signal (X22)

This signal turns on when positioning process starts after Forward start signal (Y22) was turned on.

When Forward start signal (Y22) is turned off after the start of the positioning, this signal turns off.

(20)Reverse start complete signal (X23)

This signal turns on when positioning process starts after Reverse start signal (Y23) was turned on.

When Reverse start signal (Y23) is turned off after the start of the positioning, this signal turns off.

(21)Synchronization flag (X24)

This signal turns on when the CPU module becomes accessible to the QD73A1 after the power was turned off

then on, or after the CPU module was reset.

When the module synchronization setting of the CPU module is set to asynchronous, use this signal as an

interlock to access the QD73A1 from a sequence program.

(22)Zero/gain adjustment data writing complete flag (X2A)

This signal turns on when zero/gain adjustment value writing to the QD73A1 is completed after Zero/gain

3.4 I/O Signals from/to the CPU Module 3.4.2 Details of input signals

adjustment data writing request signal (Y1A) was turned on.

When Zero/gain adjustment data writing request signal (Y1A) is turned off, this signal turns off.

ON

Zero/gain adjustment data writing complete flag (X2A)

OFF

ON

Zero/gain adjustment data writing request signal (Y1A)

OFF

Executed in a sequence program Executed by the QD73A1

Use this signal as an interlock condition to turn on/off Zero/gain adjustment data writing request signal (Y1A)

when writing the zero/gain adjustment value to the QD73A1.

For details on zero/gain adjustment, refer to the following.

Page 59, Section 4.5

Page 38 of the Mitsubishi Electronics QD73A1 user manual — (25)Operating status of the speed-position control switch mode (X2D)
Page 38 · click to enlarge
Page 38

(23)Zero/gain adjustment change complete flag (X2B)

This signal turns on when zero adjustment and gain adjustment were switched after Zero/gain adjustment

change request signal (Y1B) was turned on.

When Zero/gain adjustment change request signal (Y1B) is turned off, this signal turns off.

Cd.10

ON

OFF

ON

OFF

Executed in a sequence program Executed by the QD73A1

Use this signal as an interlock condition to turn on/off Zero/gain adjustment change request signal (Y1B) when

changing " Zero/gain adjustment specification".

Cd.10

For details on zero/gain adjustment, refer to the following.

Page 59, Section 4.5

(24)Set value change complete flag (X2C)

This signal turns on when the analog output value of zero/gain adjustment was changed after Set value change

request signal (Y1C) was turned on.

When Set value change request signal (Y1C) is turned off, this signal turns off.

ON

Set value change complete flag

OFF

(X2C)

ON

Set value change request signal

OFF

(Y1C)

Executed by the QD73A1 Executed in a sequence program

Use this signal as an interlock condition to turn on/off Set value change request signal (Y1C) when performing

zero/gain adjustment.

For details on zero/gain adjustment, refer to the following.

Page 59, Section 4.5

(25)Operating status of the speed-position control switch mode (X2D)

This signal indicates the operating status in the speed-position control switch mode.

This signal is on during speed control.

This signal is off during position control.

Show 6 more labels / short text on this page
Zero/gain adjustment · specification · Zero/gain adjustment change · complete flag (X2B) · Zero/gain adjustment change · request signal (Y1B)
Page 39 of the Mitsubishi Electronics QD73A1 user manual — Major positioning control Consequence of turning on Forward start signal (Y22)
Page 39 · click to enlarge
Page 39

CHAPTER 3 SPECIFICATIONS

3.4.3 Details of output signals

(1) Zero/gain adjustment data writing request signal (Y1A)

Turn on this signal to write the zero/gain adjustment value to the QD73A1.

For the on/off timing of this signal, refer to the detail of Zero/gain adjustment data writing complete flag (X2A).

( Page 35, Section 3.4.2 (22))

For details on zero/gain adjustment, refer to the following.

Page 59, Section 4.5

(2) Zero/gain adjustment change request signal (Y1B)

Turn on this signal to change zero adjustment and gain adjustment.

For the on/off timing of this signal, refer to the detail of Zero/gain adjustment change complete flag (X2B).

( Page 36, Section 3.4.2 (23))

For details on zero/gain adjustment, refer to the following.

Page 59, Section 4.5

(3) Set value change request signal (Y1C)

Turn on/off this signal to increase/decrease the analog output value at zero/gain adjustment.

The analog output is increased/decreased according to the value set in " Zero/gain adjustment value

Cd.11

specification".

For the on/off timing of this signal, refer to the detail of Set value change complete flag (X2C). ( Page 36,

Section 3.4.2 (24))

For details on zero/gain adjustment, refer to the following.

Page 59, Section 4.5

3.4 I/O Signals from/to the CPU Module 3.4.3 Details of output signals

(4) OPR start signal (Y20)

Turn on this signal to start OPR.

(5) Absolute positioning start signal (Y21)

Turn on this signal to start absolute system positioning (position control mode).

(6) Forward start signal (Y22)

Turn on this signal to start positioning in the address increasing direction.

The following table describes the consequence of turning on this signal for each type of positioning (major

positioning control).

Major positioning control Consequence of turning on Forward start signal (Y22)

Starts in the address increasing direction (incremental system) Two-phase trapezoidal

Speed-position control switch mode Starts in the address increasing direction

Positioning control · Position control mode · positioning control

Page 40 of the Mitsubishi Electronics QD73A1 user manual — (13)Overflow reset signal (Y29)
Page 40 · click to enlarge
Page 40

(7) Reverse start signal (Y23)

Turn on this signal to start positioning in the address decreasing direction.

The following table describes the consequence of turning on this signal for each type of positioning (major

positioning control).

Major positioning control Consequence of turning on Reverse start signal (Y23)

Starts in the address decreasing direction (incremental system) Two-phase trapezoidal

Speed-position control switch mode Starts in the address decreasing direction

(8) Forward JOG start signal (Y24)

Turn on this signal to start JOG operation in the address increasing direction.

The JOG operation continues while this signal is on.

The JOG operation decelerates and stops when this signal is turned off.

(9) Reverse JOG start signal (Y25)

Turn on this signal to start JOG operation in the address decreasing direction.

The JOG operation continues while this signal is on.

The JOG operation decelerates and stops when this signal is turned off.

(10)Speed-position mode restart signal (Y26)

Turn on this signal to restart positioning if it stopped due to Stop signal in the speed-position control switch mode.

(11)Stop signal (Y27)

Turn on this signal to decelerate and stop OPR operation, major positioning operation, or JOG operation.

If this signal is turned on during OPR, Error detection signal (X18) turns on.

(12)Error reset signal (Y28)

Turn on this signal to clear the following buffer memory data to 0 when Error detection signal (X18) is on.

  • Error code (ERR.1)

Md.3

  • Error code (ERR.2)

Md.4

When this signal is turned on, Error detection signal (X18) turns off.

(13)Overflow reset signal (Y29)

Turn on this signal to turn off Overflow signal (X19) when it is on.

For the on/off timing of this signal, refer to the detail of Overflow signal (X19). ( Page 34, Section 3.4.2 (10))

Positioning control · Position control mode · positioning control

Page 41 of the Mitsubishi Electronics QD73A1 user manual — OFF
Page 41 · click to enlarge
Page 41

CHAPTER 3 SPECIFICATIONS

(14)Underflow reset signal (Y2A)

Turn on this signal to turn off Underflow signal (X1A) when it is on.

For the on/off timing of this signal, refer to the detail of Underflow signal (X1A). ( Page 34, Section 3.4.2 (11))

(15)Speed-position switching enable signal (Y2C)

Use this signal to enable/disable Speed-position switching command signal (CHANGE) in the speed-position

control switch mode.

Turn on this signal to enable Speed-position switching command signal (CHANGE). Turn off this signal to disable

Speed-position switching command signal (CHANGE).

(16)PLC READY signal (Y2D)

This signal notifies the QD73A1 that the CPU module is operating normally.

This signal needs to be turned on beforehand to start OPR, major positioning, or JOG operation.

This signal needs to be turned off beforehand to write fixed parameters and OPR parameters.

When this signal is turned on, the QD73A1 performs the following.

  • 1: Checking fixed parameters
  • 2: Turning on QD73A1 READY signal (X11)
  • 3: Turning off Excessive error signal (X17) when it is on

When this signal is turned off while BUSY signal (X14) is on, the QD73A1 processes a deceleration stop.

When this signal is turned on while BUSY signal (X14) is on, the QD73A1 does not perform the operations 1 to 3

above.

Deceleration followed by PLC READY signal (Y2D) OFF

Even when PLC READY signal (Y2D) is turned on, the operations 1 to 3 are not performed.

3.4 I/O Signals from/to the CPU Module 3.4.3 Details of output signals

ON

PLC READY signal (Y2D)

ON

QD73A1 READY signal (X11)

OFF

ON

OFF

Executed by the QD73A1

BUSY signal (X14)

Page 42 of the Mitsubishi Electronics QD73A1 user manual — Pulse frequency Pulse width (duty ratio: 50%) Phase difference
Page 42 · click to enlarge
Page 42

3.5 Specifications of I/O Interfaces with External Devices

This section describes I/O interfaces between the QD73A1 and external devices.

3.5.1 Electrical specifications of I/O signals

This section describes electrical specifications of I/O interfaces between the QD73A1 and external devices.

(1) Input specifications

Voltage

ON

ON

OFF

OFF

Pulse

Signal name

range/Current

voltage

current

voltage

current

frequency

consumption

Supply power Input common 5 to 24VDC/

Max.60mA

Servo READY signal (READY)

Near-point dog signal (DOG)

4.75 to 26.4VDC 3V or

2.5mA or

higher 1V or lower 0.1mA or

Upper limit signal (FLS)

Lower limit signal (RLS)

Phase-A feedback pulse (PULSE A)

10.8 to 14VDC 4V or

2.7mA or

higher 1V or lower 0.1mA or

Phase-B feedback pulse (PULSE B)

Phase-Z feedback pulse (PULSE Z)

Phase-A feedback pulse (PULSE A)

4.5 to 5.5VDC 2.8V or

higher 0.8V or

Phase-B feedback pulse (PULSE B)

Phase-Z feedback pulse (PULSE Z)

Phase-A feedback pulse (PULSE A)

RS-422-A differential line receiver

Phase-B feedback pulse (PULSE B)

(Equivalent of AM26LS32 (Manufactured by Texas

Phase-Z feedback pulse (PULSE Z)

Instruments Inc.))

*1 The following table shows the pulse width and phase difference depending on pulse frequency.

Pulse frequency Pulse width (duty ratio: 50%) Phase difference

5 s or more

2.5 s or more 2.5 s or more

When the phase A leads the

1.25 s or more

phase B, the positioning

1 s or more

increases.

0.5 s or more 0.5 s or more

0.25 s or more

Show 25 more labels / short text on this page
Stop signal (STOP) · lower · higher · Speed-position switching command · signal (CHANGE) · (Open collector method) · 200kpulse/s or · higher · lower · less*1 · (TTL method) · 200kpulse/s or · lower · less*1 · (Differential output method) · EIA standard · 1Mpulse/s or · less*1 · Phase A · 200kpulse/s or less · Phase B · address (current value) · Phase A · 1Mpulse/s or less · Phase B
Page 43 of the Mitsubishi Electronics QD73A1 user manual — Signal name Analog output
Page 43 · click to enlarge
Page 43

CHAPTER 3 SPECIFICATIONS

(2) Output specifications

Max.

Signal name Analog output

voltage/current Output method Load

Load

voltage

Leakage

voltage

current

drop at

current at OFF

ON

Servo ON signal (SVON) Open collector 4.75 to

26.4VDC Max.30mA*1 1.0V or

lower 0.1mA or lower

(analog signal) 0 to ±10VDC/10mA

*1 The load current of Servo ON signal (SVON) is 30mA at the maximum. When using a miniature relay, take the load current into consideration.

3.5 Specifications of I/O Interfaces with External Devices 3.5.1 Electrical specifications of I/O signals

Speed command signal

Page 44 of the Mitsubishi Electronics QD73A1 user manual — SERVO
Page 44 · click to enlarge
Page 44

3.5.2 Signal layout for external device connectors

The following table shows signal layouts on external device connectors.

Connector

name Pin arrangement Pin number Signal name

1 Near-point dog signal (DOG)

5 Power supply (5 to 24V)

CONT.

6 Lower limit signal (RLS)

7 Upper limit signal (FLS)

8 Speed-position switching command signal (CHANGE)

Viewed from the front

9 Stop signal (STOP)

1 Servo READY signal (READY) (+ side)

2 Servo READY signal (READY) (- side)

3 Servo ON signal (SVON) (+ side)

4 Servo ON signal (SVON) (- side)

5 Phase-B feedback pulse (PULSE B) (+ side)

6 Phase-Z feedback pulse (PULSE Z) (+ side)

7 Phase-Z feedback pulse (PULSE Z) (- side)

SERVO

10 Phase-B feedback pulse (PULSE B) (- side)

11 Phase-A feedback pulse (PULSE A) (- side)

13 Phase-A feedback pulse (PULSE A) (+ side)

Viewed from the front

14 Speed command signal (- side)

15 Speed command signal (+ side)

Show 8 more labels / short text on this page
2 Empty · 3 Empty · 4 Empty · of the module · 8 Empty · 9 Analog GND · 12 Empty · of the module
Page 45 of the Mitsubishi Electronics QD73A1 user manual — SERVO
Page 45 · click to enlarge
Page 45

CHAPTER 3 SPECIFICATIONS

3.5.3 List of I/O signal details

This section describes details of signals that are input or output through external device connectors on the QD73A1.

Signal name Connector

Pin

number Signal detail

name

Phase-A feedback pulse (PULSE A)

  • Feedback pulse signals of encoder's phases A, B, and Z are

input.

Phase-B feedback pulse (PULSE B)

  • When the phase A leads the phase B, the positioning address

increases at the rising and falling edges of each phase.

Phase-Z feedback pulse (PULSE Z)

  • When the phase B leads the phase A, the positioning address

decreases at the rising and falling edges of each phase.

Phase-A feedback pulse (PULSE A)

SERVO

Phase-B feedback pulse (PULSE B)

Phase-Z feedback pulse (PULSE Z)

address -1

  • This signal is input from the limit switch placed at stroke upper

Upper limit signal (FLS)

limit position.

  • As this signal turns off, positioning stops.
  • This signal is input from the limit switch placed at stroke lower

Lower limit signal (RLS) 6

limit position.

  • As this signal turns off, positioning stops.
  • This signal is used for detection on the near-point dog during

3.5 Specifications of I/O Interfaces with External Devices 3.5.3 List of I/O signal details

Near-point dog signal (DOG) 1

OPR.

  • As the near-point dog turns on, this signal is detected.
  • Input this signal to stop positioning.

CONT.

  • As this signal is turned on, the QD73A1 cancels the positioning

Stop signal (STOP) 9

in execution. Once this signal was turned on, the operation

does not restart even if this signal is turned off.

signal (CHANGE) 8 Input this signal to switch control during the speed-position control

switch mode.

This power supply is common to the following signals.

  • Upper limit signal (FLS)
  • Lower limit signal (RLS)

Power supply (5 to 24V) 5

  • Near-point dog signal (DOG)
  • Stop signal (STOP)
  • Speed-position switching command signal (CHANGE)
Show 17 more labels / short text on this page
(+ side) · (+ side) · (+ side) · [When increased] · [When decreased] · (- side) · Phase A · Phase A · (- side) · Phase B · Phase B · (- side) · Positioning · Positioning · address +1+1+1+1+1+1+1+1 · Analog GND 9 · Speed-position switching command
Page 46 of the Mitsubishi Electronics QD73A1 user manual — SERVO
Page 46 · click to enlarge
Page 46

Signal name Connector

Pin

number Signal detail

name

  • This signal turns on when the drive unit is ready to operate.

Servo READY signal (READY)

  • Positioning cannot be started when this signal is off.
  • If this signal turns off during positioning, the system stops. The

system does not operate even if this signal is turned on again.

Servo READY signal (READY)

(- side) 2 This line is common to Servo READY signal (READY).

  • Wire this signal without fail to prevent malfunction of the

servomotor.

SERVO

  • This signal turns on automatically if there is no hardware error

Servo ON signal (SVON) (+ side) 3

at a system startup.

  • This signal turns off if an error was detected due to an

excessive error or by the QD73A1's self-diagnosis on its

hardware.

Servo ON signal (SVON) (- side) 4 This line is common to Servo ON signal (SVON).

Speed command signal (+ side) 15 The analog voltage converted from digital accumulated pulse

amount is output.

Speed command signal (- side) 14 This line is common to Speed command signal.

(+ side)

Page 47 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 3 SPECIFICATIONS
Page 47 · click to enlarge
Page 47

CHAPTER 3 SPECIFICATIONS

3.5.4 I/O interface internal circuit

This section shows internal circuits of external device interfaces on the QD73A1 in schematic diagrams.

Mitsubishi Electronics QD73A1 — CHAPTER 3 SPECIFICATIONS diagram (page 47)
Fig. 13

Pin No. Internal circuit External wiring Signal name Remark

3.5 Specifications of I/O Interfaces with External Devices 3.5.4 I/O interface internal circuit

*1 When input impedance of the servo amplifier is low, analog output level may become low due to this resistance. If that causes a problem, perform gain adjustment again with the servo amplifier being connected.

Page 48 of the Mitsubishi Electronics QD73A1 user manual — 3.5.4 I/O interface internal circuit
Page 48 · click to enlarge
Page 48
Mitsubishi Electronics QD73A1 — 3.5.4 I/O interface internal circuit diagram (page 48)
Fig. 14 · 3.5.4 I/O interface internal circuit

Pin No. Internal circuit External wiring Signal name Remark

Page 49 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 3 SPECIFICATIONS
Page 49 · click to enlarge
Page 49

CHAPTER 3 SPECIFICATIONS

3.6 Memory Configuration and Use

There are two memories in the QD73A1.

: Data setting and storage, : No data setting and storage

Data in this memory cannot be backed up. Data are erased if the power is turned off.

Area that can be accessed directly from the CPU module using sequence programs

Data in this memory can be backed up. Data are kept even if the power is turned off.

Area used to back up zero/gain adjustment data

The following table describes each memory area.

Area name Description Reference

Parameter area Area used to set and store parameters for positioning, such as positioning parameters and OPR parameters

Page 75, Section 5.2 Page 79, Section 5.3

3.6 Memory Configuration and Use

Monitor data area Area where operating statuses of a positioning system are stored Page 85, Section 5.5

Control data area Area used to set and store data to operate or control a positioning system Page 89, Section 5.6

Positioning data area Area used to set and store positioning data Page 82, Section 5.4

Zero/gain adjustment data area Area used to set and store data for zero adjustment and gain adjustment –

Reference value storage area for accumulated pulse error detection function

Area used to store the reference value for the accumulated pulse error detection function –

Show 24 more labels / short text on this page
Area configuration · Reference value · Memory · Monitor · Control · Zero/gain · storage area for · configuration Use · Parameter · Positioning · data · data · adjustment · accumulated · Backup · area · data area · area · area · data area · pulse error · detection function · Buffer memory · Flash ROM
Page 50 of the Mitsubishi Electronics QD73A1 user manual — 26 1A H
Page 50 · click to enlarge
Page 50

3.7 List of Buffer Memory Addresses

This section lists the buffer memory addresses of the QD73A1.

For details on the buffer memory, refer to the following.

Page 73, CHAPTER 5

Do not write data to system areas and area where data cannot be written from sequence programs in the buffer memory. Writing data to these areas may cause malfunction.

Default

Read/

Memory

Address

Address

Data

type *1 Name

value

Write

area

Reference

(decimal)

(hexadecimal)

0 0 H

Stroke limit upper limit 2147483647 R/W

Pr.1

1 1 H

Section 5.2

2 2H Stroke limit lower limit 0 R/W 3 3H

Pr.2

4 4H Numerator of command pulse

Pr.3

1 R/W Page 77,

multiplication for electronic gear

Section 5.2

(2) 5 5H Denominator of command pulse

Pr.4

1 R/W

multiplication for electronic gear

6 6 H

19 13 H

20 14 H

Pr.5

Speed limit value 200000 R/W

Section 5.2

(3) 21 15 H

22 16H Acceleration time 300 R/W Page 78,

Pr.6

Section 5.2

(4) 23 17H Deceleration time 300 R/W

Pr.7

24 18H In-position range 5 R/W

Section 5.2

Pr.8

25 19H Positioning mode 0 R/W

Pr.9

Section 5.2

26 1A H

39 27 H

Show 28 more labels / short text on this page
*2 · *3 · *4 · Page 76, · Positioning · (1) · parameter · Parameter · (fixed · area · parameter) · ••• · ••• · System area · Page 77, · Positioning · parameter · Parameter · (variable · area · Page 78, · parameter) · (5) · Page 78, · (6) · ••• · ••• · System area
Page 51 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 3 SPECIFICATIONS
Page 51 · click to enlarge
Page 51

CHAPTER 3 SPECIFICATIONS

Mitsubishi Electronics QD73A1 — CHAPTER 3 SPECIFICATIONS diagram (page 51)
Fig. 15

90 5AH Current value change request 0 R/W

Page 52 of the Mitsubishi Electronics QD73A1 user manual — 131 83 H
Page 52 · click to enlarge
Page 52

Default

Read/

Memory

Address

Address

Data

type *1 Name

Reference

value

Write

area

(decimal)

(hexadecimal)

100 64 H

Md.1

Current feed value 0 R

101 65 H

102 66H Actual current value 0 R 103 67H

Md.2

104 68H Error code (ERR.1) 0 R

Md.3

105 69H Error code (ERR.2) 0 R

Md.4

106 6AH Deviation counter value

0 R 107 6B H

Md.5

108 6CH Movement amount after near-

0 R 109 6D H

Md.6

110 6EH Speed-position switching

Md.7

0 R

111 6FH Control mode 0 R

Md.8

112 70H Zero/gain execution status 0 R

Md.9

113 71H Zero/gain adjustment status 0 R

Md.10

114 72H Feedrate 0 R 115 73H

Md.11

116 74H Deviation counter value (pulse) 0 R 117 75H

Section 5.5

Md.21

118 76H Movement amount after near-

Md.22

0 R 119 77 H

point dog ON (absolute value)

120 78 H

Md.12

121 79H Error occurrence

Md.13

0000 H

(YearMonth)

R

122 7AH Error occurrence

Md.14

0000 H

(DayHour)

123 7BH Error occurrence

Md.15

0000 H

(MinuteSecond)

124 7C H

Error code and error

record 0 R 125 7DH

126 7E H

data structure as record

127 7F H

128 80 H

Error code and error

record 0 R 129 81H

130 82 H

data structure as record

131 83 H

Show 27 more labels / short text on this page
*2 · *3 · *4 · (address) · Monitor · point dog ON · data · (monitor · area) · command · Monitor · Page 85, · data area · Error code 0 · Record 0 · Monitor · data · (monitor · occurrence (The same · Same as · area) · Record 1 · 0) · occurrence (The same · Same as · Record 2 · 0)
Page 53 of the Mitsubishi Electronics QD73A1 user manual — 163 A3 H
Page 53 · click to enlarge
Page 53

CHAPTER 3 SPECIFICATIONS

Default

Read/

Memory

Address

Address

Data

type *1 Name

Reference

value

Write

area

(decimal)

(hexadecimal)

132 84 H

Error code and error

133 85 H

data structure as record

134 86 H

135 87 H

136 88 H

Error code and error

record 0 R 137 89H

138 8A H

data structure as record

139 8B H

140 8C H

Error code and error

record 0 R 141 8DH

142 8E H

data structure as record

143 8F H

144 90 H

Error code and error

record 0 R 145 91H

146 92 H

data structure as record

147 93 H

148 94 H

Section 5.5

Error code and error

record 0 R 149 95H

150 96 H

data structure as record

151 97 H

152 98 H

Error code and error

3.7 List of Buffer Memory Addresses

record 0 R 153 99H

154 9A H

data structure as record

155 9B H

156 9C H

Error code and error

record 0 R 157 9DH

158 9E H

data structure as record

159 9F H

160 A0 H

Error code and error

record 0 R 161 A1H

162 A2 H

data structure as record

163 A3 H

Show 43 more labels / short text on this page
*2 · *3 · *4 · occurrence (The same · Same as · Record 3 · record 0 R · 0) · occurrence (The same · Same as · Record 4 · 0) · occurrence (The same · Same as · Record 5 · 0) · occurrence (The same · Same as · Record 6 · Monitor · 0) · data · Monitor · Page 85, · (monitor · data area · area) · occurrence (The same · Same as · Record 7 · 0) · occurrence (The same · Same as · Record 8 · 0) · occurrence (The same · Same as · Record 9 · 0) · occurrence (The same · Same as · Record 10 · 0)
Page 54 of the Mitsubishi Electronics QD73A1 user manual — 0 R
Page 54 · click to enlarge
Page 54

Default

Read/

Memory

Address

Address

Data

type *1 Name

Reference

value

Write

area

(decimal)

(hexadecimal)

164 A4 H

Error code and error

165 A5 H

data structure as record

166 A6 H

167 A7 H

168 A8 H

Error code and error

record 0 R 169 A9H

170 AA H

data structure as record

171 AB H

172 AC H

Error code and error

record 0 R 173 ADH

174 AE H

data structure as record

Section 5.5

175 AF H

176 B0 H

Error code and error

record 0 R 177 B1H

178 B2 H

data structure as record

179 B3 H

180 B4 H

Error code and error

record 0 R 181 B5H

182 B6 H

data structure as record

183 B7 H

184 B8H Error history pointer 0 R

Md.16

185 B9 H

199 C7 H

200 C8 H

Md.17

0 R

201 C9 H

202 CAH Minimum accumulated pulse

0 R 203 CB H

Md.18

Section 5.5

204 CCH Accumulated pulse error

Md.19

0 R

205 CDH Reference value measurement

Md.20

0 R

206 CE H

300 12C H

Show 49 more labels / short text on this page
*2 · *3 · *4 · occurrence (The same · Same as · Record 11 · record 0 R · 0) · occurrence (The same · Same as · Record 12 · 0) · Monitor · occurrence (The same · Same as · data · Record 13 · Monitor · Page 85, · (monitor · data area · 0) · area) · occurrence (The same · Same as · Record 14 · 0) · occurrence (The same · Same as · Record 15 · 0) · ••• · ••• · System area · Maximum accumulated pulse · value · Monitor · data · value · Monitor · Page 85, · (monitor · data area · area) · detection function status · flag · System area · ••• · •••
Page 55 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 3 SPECIFICATIONS
Page 55 · click to enlarge
Page 55

CHAPTER 3 SPECIFICATIONS

Mitsubishi Electronics QD73A1 — CHAPTER 3 SPECIFICATIONS diagram (page 55)
Fig. 16

411 19BH Reference value write request 0 R/W

*1 For types of data, refer to the following.

Page 73, Section 5.1 *2 Default values are set after the power was turned off and on or the CPU module was reset. *3 This column indicates whether the data can be read from or written to the buffer memory area through sequence programs. R: Readable W: Writable *4 For the memory configuration, refer to the following.

Page 56 of the Mitsubishi Electronics QD73A1 user manual — Screw Tightening torque range
Page 56 · click to enlarge
Page 56

CHAPTER 4 SETTINGS AND PROCEDURE

BEFORE OPERATION

This chapter describes the procedure prior to operation, part names, zero/gain adjustment, and wiring method of the

QD73A1.

4.1 Handling Precautions

This section describes the handling precautions for the QD73A1.

  • Do not disassemble the module. Doing so may cause failure, malfunction, injury, or a fire.
  • Shut off the external power supply (all phases) used in the system before mounting or removing the module.

Failure to do so may cause the module to fail or malfunction.

  • After the first use of the product, do not mount/remove the module to/from the base unit, and the terminal

block to/from the module more than 50 times (IEC 61131-2 compliant) respectively.

Exceeding the limit may cause malfunction.

  • Use the programmable controller in an environment that meets the general specifications in the user's

manual for the CPU module used.

Failure to do so may result in electric shock, fire, malfunction, or damage to or deterioration of the product.

  • To mount the module, while pressing the module mounting lever located in the lower part of the module, fully

insert the module fixing projection(s) into the hole(s) in the base unit and press the module until it snaps into

place.

Incorrect mounting may cause malfunction, failure or drop of the module.

When using the programmable controller in an environment of frequent vibrations, fix the module with a

screw.

  • Tighten the screws such as a module fixing screw within the specified torque range.

Undertightening can cause drop of the screw, short circuit or malfunction.

Overtightening can damage the screw and/or module, resulting in drop, short circuit, or malfunction.

Screw Tightening torque range

Module fixing screw (M3 screw)*1 0.36 to 0.48N • m

Connector screw (M2.6 screw) 0.20 to 0.29N • m

*1 The module can be easily fixed onto the base unit using the hook at the top of the module. However, it is recommended to secure the module with the module fixing screw if the module is subject to significant vibration. • Do not directly touch any conductive parts and electronic components of the module.

Doing so can cause malfunction or failure of the module.

  • Prevent foreign matter such as dust or wire chips from entering the module. Such foreign matter can cause a

fire, failure, or malfunction.

  • Do not drop the module case, or do not subject it to strong impact.
  • Lock the control panel so that only specialists educated in electric installation can open it.
Page 57 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 4 SETTINGS AND PROCEDURE BEFORE OPERATION
Page 57 · click to enlarge
Page 57

CHAPTER 4 SETTINGS AND PROCEDURE BEFORE OPERATION

4.2 Settings and Procedure Before Operation

This section shows the procedure before operating the QD73A1.

Mitsubishi Electronics QD73A1 — CHAPTER 4 SETTINGS AND PROCEDURE BEFORE OPERATION diagram (page 57)
Fig. 17

Mounting the module Mount the QD73A1 on a specified slot.

Zero/gain adjustment Adjust a gain using a switch on the front part of the QD73A1, or I/O signals and the buffer memory.

Operation check of the drive unit Check the operation of the drive unit with forward/ reverse JOG operations in the factory default status.

Initial setting Create a sequence program in which initial settings are configured.

Initial setting Configure the initial setting using GX Works2.

Auto refresh setting Configure the auto refresh setting using GX Works2.

Programming and debugging Create and check a sequence program.

Page 58 of the Mitsubishi Electronics QD73A1 user manual — 4.3 Part Names
Page 58 · click to enlarge
Page 58

4.3 Part Names

This section describes the part names of the QD73A1.

Mitsubishi Electronics QD73A1 — 4.3 Part Names diagram (page 58)
Fig. 18 · 4.3 Part Names

Indicates the operating status or error status of the QD73A1

Indicates the status of pulses on an encoder input phase A, B, or Z

BUSY LED Indicates the status of BUSY signal (X14) or writing of zero adjustment

3. SELECT/SET switch A switch for zero adjustment and gain adjustment

Page 61, Section 4.5 (4) UP/DOWN switch A switch to adjust an analog output voltage value

Page 59 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 4 SETTINGS AND PROCEDURE BEFORE OPERATION
Page 59 · click to enlarge
Page 59

CHAPTER 4 SETTINGS AND PROCEDURE BEFORE OPERATION

Number Name Description Reference

5. SERVO connector A connector for a drive unit Page 43, Section 3.5.3

Page 69, Section 4.6.3 6) CONT. connector A connector for external control devices

7. Serial number display Displays the serial number of the QD73A1
8. Mode switch A switch to change the operation mode to the zero/gain adjustment mode.

Page 61, Section 4.5 (4)

(DIP switch 1 and 2 are off as the factory default.)

4.3 Part Names

(a)

Page 60 of the Mitsubishi Electronics QD73A1 user manual — 4.4 LED
Page 60 · click to enlarge
Page 60

4.4 LED

The LEDs on the front of the QD73A1 indicate the statuses of the module and axis control.

Mitsubishi Electronics QD73A1 — 4.4 LED diagram (page 60)
Fig. 19

If the RUN LED does not turn on even after the power was turned off and

on, the module may be broken. Replace the module with another module.

  • ERR. LED: OFF The module is operating normally.

Read out the error code, and take the corrective action described in the

The LED turns off when the positioning is completed.

Pulses are input through the pulse input terminals (phase A, B, and Z).

The LED turns off when the zero adjustment is completed.

The LED turns off when the gain adjustment is completed.

The zero adjustment value and the gain adjustment value are being

The LED turns off when writing of the zero adjustment value and gain

Page 61 of the Mitsubishi Electronics QD73A1 user manual — (unit: pulse) Setting range Default
Page 61 · click to enlarge
Page 61

CHAPTER 4 SETTINGS AND PROCEDURE BEFORE OPERATION

4.5 Zero/gain Adjustment

Zero/gain adjustment is a process to adjust analog output voltage according to accumulated pulse amount.

Adjust the analog output voltage value according to the analog speed command input of the drive unit used.

Adjust analog output voltage using the check pins on the front of the QD73A1.

For the position of check pins, refer to the following.

Page 56, Section 4.3

(1) Zero adjustment

Adjust the analog output voltage of when accumulated pulse amount is "0". The voltage is adjusted to 0V as the

factory default. Zero adjustment may vary when the module is connected to a servomotor. In that case, perform

zero adjustment again. If the module is used with its zero adjustment being off, the connected servomotor rotates

a little when the power is turned on.

(2) Gain adjustment

Adjust the analog output voltage of when accumulated pulse amount is the maximum. In the factory default

setting, adjustment is made so that the analog output voltage becomes 10V when accumulated pulse amount is

the default value.

Adjust a gain value according to the rated speed command voltage of the drive unit used. The gain value can be

adjusted within the range of 5 to 10V.

When changing the accumulated pulse amount at the gain value output from the default value, set the

accumulated pulse amount by referring to the following reference values.

Accumulated pulse amount (unit: pulse)

Excessive

Accumulated

Reference value for the setting

4.5 Zero/gain Adjustment

(unit: pulse) Setting range Default

error

pulse setting

When the gain value

When the gain value

value

is 5V

is 10V

Initial setting The initial setting is same as the case where [Selection 4] is set.

[Selection 1] -3700 to 3700 3480 -2500 to -2000

[Selection 2] -7400 to 7400 6960 -5000 to -4000

[Selection 3] -11100 to 11100 10440 -7500 to -6000

[Selection 4] -14800 to 14800 13920 -10000 to -8000

[Selection 5] -37000 to 37000 34800 -25000 to -20000

[Selection 6] -74000 to 74000 69600 -50000 to -40000

[Selection 7] -111000 to 111000 104400 -75000 to -60000

[Selection 8] -148000 to 148000 139200 -100000 to -80000

Show 40 more labels / short text on this page
-3700 to -3250 · -3701 or less · 2000 to 2500 · 3250 to 3700 · 3701 or more · -7400 to -6500 · -7401 or less · 4000 to 5000 · 6500 to 7400 · 7401 or more · -11100 to -9750 · -11101 or less · 6000 to 7500 · 9750 to 11100 · 11101 or more · -14800 to -13000 · -14801 or less · 8000 to 10000 · 13000 to 14800 · 14801 or more · -37000 to -32500 · -37001 or less · 20000 to 25000 · 32500 to 37000 · 37001 or more · -74000 to -65000 · -74001 or less · 40000 to 50000 · 65000 to 74000 · 74001 or more · -111000 to -97500 · -111001 or less · 60000 to 75000 · 97500 to 111000 · 111001 or more · -148000 to -130000 · -148001 or less · 80000 to 100000 · 130000 to 148000 · 148001 or more
Page 62 of the Mitsubishi Electronics QD73A1 user manual — (3) Zero/gain adjustment setting range
Page 62 · click to enlarge
Page 62
  • When setting a smaller value than the above reference value (larger value for a negative value) as the accumulated pulse amount at the gain value output, making the setting value too small at a time may cause the hunting of a servomotor. To make the accumulated pulse amount value smaller, check the machine operation and adjust the value.
  • To change "Accumulated pulse setting" after the gain adjustment execution where the accumulated pulse amount at the gain value output has been changed from the default value, execute the gain adjustment again.

Gain adjustment can be performed in the following two methods.

  • Adjusting with the default accumulated pulse amount
  • Adjusting with specified accumulated pulse amount

(a) Adjusting gain with the default accumulated pulse amount

Follow the procedure below.

1 Change the operation mode to the zero/gain adjustment mode.

2 Set "Accumulated pulse setting" in the switch setting according to the necessary accumulated pulse amount.

3 Adjust the voltage to be the necessary voltage value between the check pins.

(b) Adjusting gain with specified accumulated pulse amount

Follow the procedure below.

1 Change the operation mode to the zero/gain adjustment mode.

2 Set "Accumulated pulse setting" in the switch setting according to the necessary accumulated pulse amount. (Do not

specify amount that exceeds the setting range.)

Write the accumulated pulse amount using a sequence program.

[When one of the selections 1 to 4 is specified in "Accumulated pulse setting"]

Set the specified accumulated pulse amount in " Analog output adjustment area 1".

Cd.5

Accumulated pulse amount write command

[When one of the selections 5 to 8 is specified in "Accumulated pulse setting"]

Set the specified accumulated pulse amount in " Analog output adjustment area 2".

Cd.9

Accumulated pulse amount write command

4 Adjust the voltage to be the necessary voltage value between the check pins.

(3) Zero/gain adjustment setting range

When performing zero/gain adjustment, satisfy the following two conditions.

  • Setting range: -10 to 10V
  • The difference between a gain value and zero value is as follows.

In case of positive accumulated pulse amount (Gain value) - (Zero value) 5.0V

In case of negative accumulated pulse amount (Gain value) - (Zero value) -5.0V

Page 63 of the Mitsubishi Electronics QD73A1 user manual — GAIN
Page 63 · click to enlarge
Page 63

CHAPTER 4 SETTINGS AND PROCEDURE BEFORE OPERATION

(4) Setting method

The following are the procedures for zero adjustment and gain adjustment.

(a) When using the switches on the front of the QD73A1

NO

Set the servomotor in the servo-lock status.

Is the ERR.LED off?*3

YES

Turn on both DIP switch 1 and 2 on the lower part of the module, then turn on the power.*1

Specify gain adjustment by changing the SELECT/SET switch to SELECT, while checking the GAIN LED. (Zero/gain adjustment switches every time when the switch is set to SELECT.)

Check that the module is in the zero/gain adjustment mode on the RUN LED. (The LED flashes in the zero/gain adjustment mode.)

ZERO

GAIN

Configure "Accumulated pulse setting" in the switch setting, and write it to the CPU module.

ON

Turn off then on the power, or reset the CPU module.

Adjust the voltage to be the gain value between check pins using the UP/DOWN switch. (Holding the switch increases the adjustment amount.)

Specify zero adjustment by changing the SELECT/SET switch to SELECT, while checking the ZERO LED. (Zero/gain adjustment switches every time when the switch is set to SELECT.)

4.5 Zero/gain Adjustment

Set the SELECT/SET switch to the SET side and check that the BUSY LED turns on. After the BUSY LED turned off, set the SELECT/SET switch back to the center.*2

ZERO

ON

NO

Is the ERR.LED off?*3

GAIN

YES

Adjust the voltage to be 0V between check pins using the UP/DOWN switch. (Holding the switch increases the adjustment amount.)

Turn off the power, then turn off both DIP switch 1 and 2 on the lower part of the module.

Set the SELECT/SET switch to the SET side and check that the BUSY LED turns on. After the BUSY LED turned off, set the SELECT/SET switch back to the center.*2

*1 The operation mode cannot be switched to the zero/gain adjustment mode if the power is turned on ahead of turning on DIP switch 1 and 2. *2 The zero adjustment value and gain adjustment value are recorded in the flash ROM inside the QD73A1 by setting the SELECT/SET switch on the SET side, and they are not erased even at a power-off. *3 If an error occurs in the zero/gain adjustment mode, the ERR. LED turns on. If the ERR. LED is on, turn on Error reset signal (Y28) then perform zero/gain adjustment again.

Show 6 more labels / short text on this page
Start · Gain adjustment · Gain adjustment · Zero adjustment · Zero adjustment · End
Page 64 of the Mitsubishi Electronics QD73A1 user manual — YES
Page 64 · click to enlarge
Page 64

(b) When using I/O signals and the buffer memory

Write the adjustment amount of the voltage between check pins to " Cd.11 Zero/gain adjustment value specification".

Write the adjustment amount of the voltage between check pins to " Cd.11 Zero/gain adjustment value specification".

Set the servomotor in the servo-lock status.

Turn on the power.

Turn on Set value change request signal (Y1C).

Turn on Set value change request signal (Y1C).

Configure the following items in the switch setting, and write them to the CPU module. "Accumulated pulse setting": Set accumulated pulse amount. "Zero/gain adjustment mode/Normal mode setting": Select "Zero/gain adjustment mode"

Check that Set value change complete flag (X2C) turned on following the change of voltage between check pins. Then, turn off Set value change request signal (Y1C). (Check that Set value change complete flag (X2C) is off after turning off Set value change request signal (Y1C).)

Check that Set value change complete flag (X2C) turned on following the change of voltage between check pins. Then, turn off Set value change request signal (Y1C). (Check that Set value change complete flag (X2C) is off after turning off Set value change request signal (Y1C).)

Turn off then on the power, or reset the CPU module.

NO

Is the voltage between check pins equal to

Is the voltage between check pins 0V?

NO

Check that " Md.9 Zero/gain execution status" is "2: In the zero/gain adjustment mode (switch setting)".

YES

YES

Turn on Zero/gain adjustment data writing request signal (Y1A).*1

Set " Cd.10 Zero/gain adjustment specification to "1: Zero adjustment".

Set " Cd.10 Zero/gain adjustment specification to "2: Gain adjustment".

Check that Zero/gain adjustment data writing complete flag (X2A) is on.

Turn on Zero/gain adjustment change request signal (Y1B).

Turn on Zero/gain adjustment change request signal (Y1B).

Turn off Zero/gain adjustment data writing request signal (Y1A).

Check that Zero/gain adjustment change complete flag (X2B) is on.

Check that Zero/gain adjustment change complete flag (X2B) is on.

Check that Zero/gain adjustment data writing complete flag (X2A) is off.

Turn off Zero/gain adjustment change request signal (Y1B).

Turn off Zero/gain adjustment change request signal (Y1B).

Check that Zero/gain adjustment change complete flag (X2B) is off.

Check that Zero/gain adjustment change complete flag (X2B) is off.

NO

Is the ERR.LED off?*2

YES

Check that " Md.10 Zero/gain adjustment status" is "1: Adjusting zero".

Check that " Md.10 Zero/gain adjustment status" is "2: Adjusting gain".

Change "Zero/gain adjustment mode/ Normal mode setting" to Normal mode" in the switch setting.

*1 The zero adjustment value and gain adjustment value are recorded in the flash ROM inside the QD73A1 by turning on Zero/gain adjustment data writing request signal (Y1A), and they are not erased even at a power-off. *2 If an error occurs in the zero/gain adjustment mode, the ERR. LED turns on. If the ERR. LED is on, turn on Error reset signal (Y28) then perform zero/gain adjustment again.

Show 5 more labels / short text on this page
Start · the gain value? · Zero adjustment · Gain adjustment · End
Page 65 of the Mitsubishi Electronics QD73A1 user manual — Buffer memory
Page 65 · click to enlarge
Page 65

CHAPTER 4 SETTINGS AND PROCEDURE BEFORE OPERATION

(5) Restoring the zero/gain adjustment value of the factory default

Writing "1" in " Factory default zero/gain adjustment value restoration request" restores the zero/gain

Cd.12

adjustment value of the factory default. Once the restoration was completed, the QD73A1 sets "0" in

" Factory default zero/gain adjustment value restoration request".

Cd.12

Once the restoration was completed, analog output voltage becomes 0V and the QD73A1 sets "1: Adjusting

zero" in " Zero/gain adjustment status".

Md.10

Cd.12

adjustment mode.

Buffer memory

Setting item Setting range Default value Execution condition

address

(decimal)

1. Restore the

The module must be in

Cd.12

mode.

Zero value and gain value of the factory default are set as below.

  • Zero value: 0V
  • Gain value: 10V Note that the values above were set when "Accumulated pulse setting" was the default value (-14800 to 14800pulse).

4.5 Zero/gain Adjustment

Show 6 more labels / short text on this page
Factory default zero/gain · adjustment value restoration · zero/gain adjustment · the zero/gain adjustment · request · value
Page 66 of the Mitsubishi Electronics QD73A1 user manual — Screw Tightening torque range
Page 66 · click to enlarge
Page 66

4.6 Wiring

This section describes precautions on wiring the QD73A1 and external devices, and connection of external device

connectors.

4.6.1 Wiring precautions

This section describes the precautions on wiring.

  • Check the terminal layout beforehand to wire cables to the module correctly.
  • Connectors for external devices must be crimped or pressed with the tool specified by the manufacturer, or

must be correctly soldered. Incomplete soldering or crimping may result in malfunction.

  • Prevent foreign matter such as dust or wire chips from entering the module. Such foreign matter can cause

a fire, failure, or malfunction.

  • A protective film is attached to the top of the module to prevent foreign matter, such as wire chips, from

entering the module during wiring. Do not remove the film during wiring.

Remove it for heat dissipation before system operation.

  • Connect the external device connectors to the connectors on the module and tighten the screws securely.

Tighten the connector screws within the specified torque range.

Undertightening can cause short circuit, fire, or malfunction.

Overtightening can damage the screw and/or module, resulting in drop, short circuit, fire, or malfunction.

Screw Tightening torque range

Connector screw (M2.6 screw) 0.20 to 0.29N • m

  • When disconnecting a cable from the module or the drive unit, do not pull the cable by the cable part.

Disconnect the cable holding the connector.

Pulling a cable connected to the module or the drive unit can cause malfunction.

Such action can also damage the module, drive unit, or cable.

  • Do not install the connection cables for external I/O signals and for the drive unit together with the main

circuit lines, power cables, or load circuit lines of a device other than the programmable controller. Keep a

distance of 100mm or more between them.

Failure to do so may result in malfunction due to noise, surges, and induction.

  • Place the cables in a duct or clamp them. If not, dangling cable may swing or inadvertently be pulled,

resulting in damage to the module, drive unit, or cables, or malfunction due to poor contact.

Page 67 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 4 SETTINGS AND PROCEDURE BEFORE OPERATION
Page 67 · click to enlarge
Page 67

CHAPTER 4 SETTINGS AND PROCEDURE BEFORE OPERATION

  • As a measure against noise, use shielded cables if the cables connected to the module are close (less than

100mm) to a power cable.

Ground the shields of shielded cables to the control panel securely on the module side.

  • To comply with EMC and Low Voltage Directives, ground shielded cables to the control panel using the

AD75CK cable clamp (manufactured by Mitsubishi Electric).

(Ground the shield parts at a point within 20 to 30cm from the module.)

Mitsubishi Electronics QD73A1 — CHAPTER 4 SETTINGS AND PROCEDURE BEFORE OPERATION diagram (page 67)
Fig. 20

For details on the AD75CK, refer to the following.

AD75CK-type Cable Clamping Instruction Manual

  • The length of the cable between the module and the drive unit is 1 to 3m generally. The length depends on

the specifications of the drive unit. Review the specifications of the drive unit to be used.

  • The length of the cable between the module and the encoder is as listed below generally. The length
Mitsubishi Electronics QD73A1 — CHAPTER 4 SETTINGS AND PROCEDURE BEFORE OPERATION diagram (page 67)
Fig. 21

depends on the specifications of the encoder. Review the specifications of the encoder to be used. Use

shielded twisted pair cable for the connection with the encoder.

  • Connect the module and Servo ON signal of the drive unit without fail. In addition, do not turn on/off Servo

ON signal externally. If Servo ON signal is not connected, the motor may rotate even in case of a CPU error.

Page 68 of the Mitsubishi Electronics QD73A1 user manual — × DIR
Page 68 · click to enlarge
Page 68

4.6.2 Precautions when connecting an encoder

This section describes precautions when connecting an encoder.

(1) Operation of the QD73A1 (deviation counter and feedback pulses)

The deviation counter in the QD73A1 counts up and down.

An addition/subtraction switchover can be processed through the phases of feedback pulses.

When "0: Positive voltage is output when the positioning address increases." is set for "Rotation direction setting"

in the switch setting.

When feedback pulses are input with the phase A leading the

phase B by 90°, the number of command pulses is subtracted.

This input method is for counting positive command pulses when

the speed command is positive voltage (when the motor is rotating

forward).

When feedback pulses are input with the phase B leading the

phase A by 90°, the number of command pulses is added.

This input method is for counting negative command pulses when

the speed command is negative voltage (when the motor is

rotating reverse).

If the sequence of the phase A and phase B is reversed, the number of command pulses and feedback pulses

are counted together. This can cause an excessive error of accumulated pulses, resulting in the stop of the

control.

(a) Switch setting and the encoder

When "1Negative voltage is output when the positioning address increases." is set for "Rotation direction

setting" in the switch setting, the count process (positive or negative) of the feedback pulses varies depending

on "Feed back pulse addition/subtraction setting" of the switch setting as shown below.

Switch setting Feedback pulse

When the phase A

When the phase B

"Rotation direction setting" "Feed back pulse

proceeds 90 degrees than

proceeds 90 degrees than

0. Positive voltage is output when the positioning address increases. - Subtraction Addition
0. Add when the phase A proceeds 90 degrees than phase B. Addition Subtraction
1. Negative voltage is output when the positioning address increases.
1. Subtract when the phase A proceeds 90 degrees than phase B. Subtraction Addition

× DIR

When the phase A proceeds 90 degrees

When the phase B proceeds 90 degrees

Rotation direction setting When 0 is set: DIR = 1 When 1 is set: DIR = -1

- (subtraction) + (addition)

+ (addition) - (subtraction)

- (subtraction) + (addition)

Show 28 more labels / short text on this page
Phase A · Phase B · Phase A · Phase B · addition/subtraction setting" · phase B · phase A · Command · pulse · Deviation · D/A converter · Analog voltage · counter · + · +/- · Feedback pulse addition · Feedback pulse · Rotation direction · Feedback pulse · /subtraction · addition/ subtraction setting · setting · setting · than phase B · than phase A · Multiplication · setting · Feedback pulse
Page 69 of the Mitsubishi Electronics QD73A1 user manual — B
Page 69 · click to enlarge
Page 69

CHAPTER 4 SETTINGS AND PROCEDURE BEFORE OPERATION

For details on "Rotation direction setting" in the switch setting, refer to the following.

Page 101, Section 6.2.1

The connection between the QD73A1 and the encoder varies depending on "Rotation direction setting" and

"Feed back pulse addition/subtraction setting" of the switch setting.

Ex. When the rotation directions of the motor and encoder are as below and the motor rotates forward when

positive voltage is applied to the servo amplifier

Mitsubishi Electronics QD73A1 — CHAPTER 4 SETTINGS AND PROCEDURE BEFORE OPERATION diagram (page 69)
Fig. 22

Suppose the condition of the feedback pulses from the

encoder asthe phase A is ahead of the phase B by 90°

in case of forward run.

Switch setting

Connection Rotation direction

Feed back pulse

setting

addition/subtraction setting

directions of the motor

0. Positive voltage is

B

and the encoder are the

address increases.

directions of the motor

B

and the encoder are

4.6 Wiring 4.6.2 Precautions when connecting an encoder

directions of the motor

and the encoder are the

B

0. Add when the phase A

proceeds 90 degrees than

phase B.

directions of the motor

1. Negative voltage is

B

and the encoder are

address increases.

directions of the motor

B

and the encoder are the

1. Subtract when the phase A

proceeds 90 degrees than

phase B.

directions of the motor

B

and the encoder are

Show 55 more labels / short text on this page
Forward · Reverse · Forward · Reverse · run · run · run · run · Servomotor Encoder · When the rotation · Phase · Phase · A Phase · A Phase · B Encoder QD73A1 · output when the · same · positioning · When the rotation · Phase · Phase · A Phase · A Phase · B Encoder QD73A1 · different · When the rotation · Phase · Phase · A Phase · A Phase · B Encoder QD73A1 · same · When the rotation · Phase · Phase · A Phase · A Phase · B Encoder QD73A1 · output when the · different · positioning · When the rotation · Phase · Phase · A Phase · A Phase · B Encoder QD73A1 · same · When the rotation · Phase · Phase · A Phase · A Phase · B Encoder QD73A1 · different
Page 70 of the Mitsubishi Electronics QD73A1 user manual — SN75113
Page 70 · click to enlarge
Page 70
  • If the connection of the QD73A1 and the encoder is incorrect, the motor rotates at a power-on and Excessive error signal (X17) turns on.
  • To replace the positioning module AD70/A1SD70 with the QD73A1 while using the same equipment of the servo amplifier, encoder, and external wiring in the existing system, check the setting of slide switch 1 (rotation direction setting) of the AD70/A1SD70. If the slide switch 1 (rotation direction setting) is off ("Negative voltage is output when the positioning address increases" is set), set "1: Subtract when the phase A proceeds 90 degrees than phase B." for "Feed back pulse addition/subtraction setting" in the switch setting of the QD73A1.

(2) Connection between the QD73A1 and each type of encoder

The following table shows the connection between the QD73A1 and each type of encoder.

Set the output type of the encoder to be used in "Encoder I/F setting" of the switch setting.

For details on "Encoder I/F setting" in the switch setting, refer to the following.

Page 100, Section 6.2

Encoder output type "Encoder I/F setting" Connection

QD73A1

Phase APin 13 Phase B: Pin 5 Phase Z: Pin 6

Open collector output type Open collector output

Phase APin 11 Phase B: Pin 10 Phase Z: Pin 7

QD73A1

Phase APin 13 Phase B: Pin 5 Phase Z: Pin 6

TTL output type TTL output

Phase APin 11 Phase B: Pin 10 Phase Z: Pin 7

QD73A1

Phase APin 13 Phase B: Pin 5 Phase Z: Pin 6

Differential output type Differential output

Phase APin 11 Phase B: Pin 10 Phase Z: Pin 7

SN75113

Encoder · Encoder · Encoder

Page 71 of the Mitsubishi Electronics QD73A1 user manual — protective seal around the part of the wires which
Page 71 · click to enlarge
Page 71

CHAPTER 4 SETTINGS AND PROCEDURE BEFORE OPERATION

4.6.3 External device connectors

This section describes the assemblage of an external device connector and its connection method.

(1) Assembling a connector

The following connectors are required to connect the QD73A1 and external devices.

  • A 9-pin connector (pin type): For the CONT. connector (control signal connection)
  • A 15-pin connector (pin type): For the SERVO connector (drive unit connection)

The connectors are composed of the following parts.

Mitsubishi Electronics QD73A1 — (1) Assembling a connector diagram (page 71)
Fig. 23 · (1) Assembling a connector

Protective tube (For a 15-pin connector only)

Cover A Cover B Wire clamp

Assemble the connectors as follows.

1. Thread wires through the protection tube (for the 15-

pin connector only).

2. Solder the wires to the connection part.
Mitsubishi Electronics QD73A1 — 1. Thread wires through the protection tube (for the 15- diagram (page 71)
Fig. 24 · 1. Thread wires through the protection tube (for the…

4.6 Wiring 4.6.3 External device connectors

3. Attach the connection part to cover A, and wrap the

Wrap the wires with

Mitsubishi Electronics QD73A1 — 3. Attach the connection part to cover A, and wrap the diagram (page 71)
Fig. 25 · 3. Attach the connection part to cover A, and wrap t…

protective seal around the part of the wires which

a protective seal.

contacts the wire clamp.

4. Slide the protection tube over the protective seal (for the 15-pin connector only).

(To the next page)

Show 8 more labels / short text on this page
Protective seal · Screw B · Screw C · Screw A · Connection part · Nut · Connection part · Cover A
Page 72 of the Mitsubishi Electronics QD73A1 user manual — 7. Put the cover B over the cover A, and fasten them
Page 72 · click to enlarge
Page 72

(From the previous page)

5. Fix the protective seal part or the protection tube

Mitsubishi Electronics QD73A1 — 5. Fix the protective seal part or the protection tube diagram (page 72)
Fig. 26 · 5. Fix the protective seal part or the protection tu…

part with the wire clamp using the screws A.

6. Attach the screws C to the cover A.
Mitsubishi Electronics QD73A1 — 5. Fix the protective seal part or the protection tube diagram (page 72)
Fig. 27 · 5. Fix the protective seal part or the protection tu…

7. Put the cover B over the cover A, and fasten them

Mitsubishi Electronics QD73A1 — 7. Put the cover B over the cover A, and fasten them diagram (page 72)
Fig. 28 · 7. Put the cover B over the cover A, and fasten them

using the screws B and nuts.

Show 7 more labels / short text on this page
Wire clamp · Screw A · Screw A · Screw C · Screw C · Screw B · End
Page 73 of the Mitsubishi Electronics QD73A1 user manual — (b) Connection between the connectors and wires
Page 73 · click to enlarge
Page 73

CHAPTER 4 SETTINGS AND PROCEDURE BEFORE OPERATION

(2) Wiring connectors

The figure below shows the pin arrangement on the connectors.

Wire pins correctly according to the signal assigned to each pin number.

For details on the signal assigned to each pin number, refer to the following.

Page 43, Section 3.5.3

from the wire side

15-pin connector Applies to the SERVO. connector

9-pin connector Applies to the CONT. connector

(a) Applicable wire size

The applicable wire size is 0.3mm2 or less. If thicker wires are used, the wire clamp cannot be attached.

(b) Connection between the connectors and wires

Solder the wires to the pins.

4.6 Wiring 4.6.3 External device connectors

Strip parts of wire jackets properly to avoid a short circuit due to wire chips or solder chips.

If the signal line is exposed, malfunction may occur due to static electricity. Cover and protect the connector

pins with heat shrinkable insulation tubes.

Mitsubishi Electronics QD73A1 — (b) Connection between the connectors and wires diagram (page 73)
Fig. 29 · (b) Connection between the connectors and wires

Pin arrangement viewed · Soldering · Wire

Page 74 of the Mitsubishi Electronics QD73A1 user manual — 17JE-23150-02(D8A)
Page 74 · click to enlarge
Page 74

(c) Connector type and the manufacturer

The following table lists applicable 9-pin connector and 15-pin connector. When wiring, use applicable wire and

an appropriate tightening torque.

External wiring connector Wire

Model Tightening torque Diameter Type Material Temperature

rating

17JE-23090-02(D8A)

(manufactured by DDK Ltd.)

0.20 to 0.29N • m 28 to

24AWG Stranded Copper 75°C or more 15-pin connector for

17JE-23150-02(D8A)

(manufactured by DDK Ltd.)

To contact the manufacturer regarding the connectors, refer to the following.

http://www.ddknet.co.jp/English/index.html

Show 5 more labels / short text on this page
9-pin connector for · external · wiring (pin type) · external · wiring (pin type)
Page 75 of the Mitsubishi Electronics QD73A1 user manual — 5.1 Types of Data
Page 75 · click to enlarge
Page 75

CHAPTER 5 DATA USED FOR POSITIONING

CHAPTER 5 DATA USED FOR POSITIONING

This chapter describes parameters and data used for positioning.

5.1 Types of Data

The parameters and data required to carry out control with the QD73A1 include "setting data", "monitor data", and

"control data" shown below.

Setting data (Data to be set beforehand according to the machinery and application)

Set parameters that are fixed beforehand depending on the mechanical system.

( to Pr.13 )

Pr.1

If a setting of fixed parameters is outside the setting range, default values will be set to all of the fixed parameters for the control. Note

( to Pr.9 ) Pr.1

Set parameters that vary depending on each positioning control.

If a setting of variable parameters is outside the setting range, a default value will be set to only the corresponding parameter for the control. Note

Set data for OPR.

( to Pr.13 ) Pr.10

Positioning data Positioning data

Set start data for major positioning control.

( to Da.5 ) Da.1

5.1 Types of Data

  • The data can be set using GX Works2.
  • Default values are determined for setting data parameters, and are set as the factory default. Keep the unused parameters to the default.
  • Fixed parameters and OPR parameters are activated when PLC READY signal (Y2D) is turned on.
  • Variable parameters and positioning data can be changed even when PLC READY signal (Y2D) is on. Although, the change that is made during operation is not reflected since the data set at the start of major positioning control or JOG operation are valid. The change will be reflected at the next start.

Monitor data (Data that indicates the control status. The data can be monitored when necessary.)

Monitoring area Monitor data such as a current position, error codes, and error history.

( to Md.22 ) Md.1

Show 6 more labels / short text on this page
Parameters · Positioning parameters · Fixed parameters · Variable parameters · OPR parameters · OPR parameters
Page 76 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 5 DATA USED FOR POSITIONING
Page 76 · click to enlarge
Page 76

Control data (Data for the user to control the positioning system)

Set data for operation and data for current value change or speed change during operation.

( to , , to to Cd.4 Cd.6 Cd.8 Cd.13 Cd.20 ) Cd.1

data area Set data for zero/gain adjustment.

( , Cd.9 Cd.12 to ) Cd.5

Set control data using sequence programs.

Control change area · Zero/gain adjustment

Page 77 of the Mitsubishi Electronics QD73A1 user manual — 1/50 CMX/CDV 50)
Page 77 · click to enlarge
Page 77

CHAPTER 5 DATA USED FOR POSITIONING

5.2 Positioning Parameters

This section describes the details of positioning parameters.

Item Setting range Default value

Stroke limit upper limit

Pr.1

5.2 (1) Stroke limit lower limit 0pulse 2

Pr.2

Pr.3

electronic gear (CMX) 1 to 9999

(Satisfy the following condition.

5.2 (2) Denominator of

1/50 CMX/CDV 50)

Pr.4

Speed limit value 10 to 4000000pulse/s

(Set in the unit of 10pulse/s.) 200000pulse/s 20

Pr.5

5.2 (3)

2 to 9999ms 300ms 22 Page 78,

Pr.6

Pr.7

5.2 (4) Deceleration time 23

Pr.8

In-position range 1 to 20479pulse 5pulse 24

5.2 Positioning Parameters

5.2 (5)

0. Position control mode
0. Position control
1. Speed-position control switch

Pr.9

5.2 (6)

  • The set data of fixed parameters are activated when PLC READY signal (Y2D) is turned on, and the error check is executed at the same time.
  • Variable parameters can be set any time, but the error check is executed when a start signal is turned on.
Show 33 more labels / short text on this page
Buffer · memory · Reference · address · (decimal) · 2147483647pulse 0 · 1 Page 76, · -2147483648 to · Section · 2147483647pulse · Numerator of · Fixed · command pulse · parameter · multiplication for · Page 77, · Section · command pulse · multiplication for · electronic gear (CDV) · Page 77, · Section · Acceleration time · Section · Variable · parameter · Page 78, · Section · Page 78, · Positioning mode · mode 25 · Section · mode
Page 78 of the Mitsubishi Electronics QD73A1 user manual — Remark
Page 78 · click to enlarge
Page 78

(1) Stroke limit upper limit, Stroke limit lower limit

Pr.1 Pr.2

Set the upper and lower limits of the workpiece moving range.

Mitsubishi Electronics QD73A1 — (1) Stroke limit upper limit, Stroke limit lower limit diagram (page 78)
Fig. 30 · (1) Stroke limit upper limit, Stroke limit lower lim…

For details on the stroke limit function, refer to the following.

Page 213, Section 11.3

Remark

  • In general, the OP is set at the lower limit or upper limit of the stroke limit.
  • Setting the upper and lower limits of the stroke limit prevents the workpiece to overrun the set range; although, in addition, place emergency stop limit switches (upper limit switch (FLS)/lower limit switch (RLS)) outside and near the stroke limit range.
  • The stroke limits are not checked during speed control.
  • To disable the stroke limit function, set the same value to " Stroke limit upper limit" and " Stroke limit lower limit".

Pr.1 Pr.2

Page 79 of the Mitsubishi Electronics QD73A1 user manual — Remark
Page 79 · click to enlarge
Page 79

CHAPTER 5 DATA USED FOR POSITIONING

(2) Numerator of command pulse multiplication for electronic gear,

Pr.3

Denominator of command pulse multiplication for electronic gear

Pr.4

Set the numerator (CMX) and denominator (CDV) of command pulse multiplication for electronic gear.

Mitsubishi Electronics QD73A1 — Denominator of command pulse multiplication for electronic gear diagram (page 79)
Fig. 31 · Denominator of command pulse multiplication for elec…

For details on the electronic gear function, refer to the following.

Page 209, Section 11.1

Remark

  • Machine movement amount per one command pulse can be changed using the command pulse multiplication setting.
  • Electronic gear is active on all of OPR control, major positioning control, and JOG operation.
  • The module operates with the positioning speed and movement amount that are multiplied by the set value for electronic gear. Satisfy the following condition when setting electronic gear. Positioning speed × Electronic gear 4Mpulse/s

When the positioning speed value that is multiplied by the set value of electronic gear exceeds " Speed limit value", the limit value is ignored. On the other hand, if the speed exceeds 4Mpulse/s, the error "Outside the command frequency range" (error code: 104) occurs. In this case, the speed is 4Mpulse/s, resulting in a positioning error.

Pr.5

  • When there are decimal pulses, the fractions are maintained inside and accumulated for the next command.

5.2 Positioning Parameters

  • If positioning is continued after the CPU module was reset, a positioning error by the fractions of pulses occurs due to electronic gear (when CMX/CDV 1). In that case, execute OPR.

(3) Speed limit value

Pr.5

Set the upper limit speed of major positioning control or JOG operation. If command speed that is faster than this

limit is specified, the speed is limited to this value.

Remark

  • If speed for OPR control is set to the one faster than " Speed limit value", the error "OPR speed Outside the setting range" (error code: 20) occurs at the start of OPR.

Pr.5

  • Positioning speed must be limited properly depending on the device and control subject.
  • Set a value in a unit of 10 pulses. If a single digit is set, the value is rounded off.
Page 80 of the Mitsubishi Electronics QD73A1 user manual — (6) Positioning mode
Page 80 · click to enlarge
Page 80

(4) Acceleration time, Deceleration time

Pr.6 Pr.7

  • Acceleration time: Set the time takes for speed (0) to reach the value in " Speed limit value".
Mitsubishi Electronics QD73A1 — (4) Acceleration time, Deceleration time diagram (page 80)
Fig. 32 · (4) Acceleration time, Deceleration time
  • Deceleration time: Set the time takes for the speed (the value in " Speed limit value") to reach 0.

Remark

  • The parameters are active for OPR control, major positioning control, and JOG operation.
  • When the set positioning speed is lower than the value in " Speed limit value", the actual acceleration/deceleration time is shorter than the set value of the parameters.

Pr.5

(5) In-position range

Pr.8

Set the accumulated pulse amount where In-position signal (X16) turns on.

In-position signal (X16) can be used as the signal right before Positioning complete signal (X15).

For details on the in-position function, refer to the following.

Page 221, Section 11.8

(6) Positioning mode

Pr.9

Select a control mode of major positioning from the position control mode or the speed-position control switch

mode.

If a value other than 0 and 1 is set, the error "Positioning mode Outside the setting range" (error code: 14) occurs. Although, the QD73A1 checks the setting range only for the start by Forward start signal (Y22) or Reverse start signal (Y23). For the start by the following signals, the above error does not occur even if the set value is outside the setting range.

  • OPR start signal (Y20)
  • Absolute positioning start signal (Y21)
  • Forward JOG start signal (Y24)
  • Reverse JOG start signal (Y25)
Page 81 of the Mitsubishi Electronics QD73A1 user manual — (2) OPR speed
Page 81 · click to enlarge
Page 81

CHAPTER 5 DATA USED FOR POSITIONING

5.3 OPR Parameters

This section describes the details of OPR parameters.

Item Setting range Default value

OP address -2147483648 to

41 Page 79, Section 5.3 (1)

Pr.10

OPR speed 1 to 4000000pulse/s 10000pulse/s 42

Pr.11

43 Page 79, Section 5.3 (2)

Creep speed 1 to 4000000pulse/s 1000pulse/s 44

45 Page 80, Section 5.3 (3)

Pr.12

Setting for the movement

amount after near-point dog ON 0 to 2147483647pulse 75pulse 46

47 Page 81, Section 5.3 (4)

Pr.13

The set data of OPR parameters are activated when PLC READY signal (Y2D) is turned on, and the error check is executed when OPR start signal (Y20) is turned on.

For details on OPR control, refer to the following.

Page 178, CHAPTER 8

(1) OP address

Pr.10

Set the address that is the reference point of major positioning control.

Upon completion of OPR, the set value is stored in the current value monitor (" Current feed value" and

Md.1

5.3 OPR Parameters

" Actual current value").

Md.2

(2) OPR speed

Pr.11

Set the speed of OPR control.

Satisfy the following condition when setting the speed.

Creep speed OPR speed Speed limit value

Pr.12 Pr.11 Pr.5

If the OPR speed exceeds " Speed limit value", the error "OPR speed Outside the setting range" (error

Pr.5

code: 20) occurs, and the OPR is not executed.

Show 5 more labels / short text on this page
Buffer memory · address · Reference · (decimal) · 2147483647pulse 0pulse 40
Page 82 of the Mitsubishi Electronics QD73A1 user manual — ON
Page 82 · click to enlarge
Page 82

(3) Creep speed

Pr.12

Once the near-point dog turns on, the control decelerates from " OPR speed" and stops. Set the speed of

Pr.11

right before the stop, which is a creep speed.

Pr.11

Pr.12

ON

OFF

(DOG)

Satisfy the following condition when setting the speed.

Creep speed OPR speed Speed limit value

Pr.12 Pr.11 Pr.5

If the creep speed exceeds " OPR speed", the error "Creep speed Outside the setting range" (error code:

Pr.11

21. occurs, and the OPR is not executed.
Show 7 more labels / short text on this page
OPR speed · OPR start · Creep speed · t · Near-point · dog signal · Zero signal
Page 83 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 5 DATA USED FOR POSITIONING
Page 83 · click to enlarge
Page 83

CHAPTER 5 DATA USED FOR POSITIONING

(4) Setting for the movement amount after near-point dog ON

Pr.13

When the OPR method is the count method, set the movement amount from the position where Near-point dog

signal (X1C) turns on to the original point. Set a value equal to or greater than the deceleration distance from the

OPR speed to the creep speed.

Deceleration distance (pulse) =

(OPR speed + Creep speed) (pulse/s)

Actual deceleration time (ms)

The following are the setting precautions.

  • Set pulse amount so that the position moved from the near-point dog ON does not overlap with Zero signal.
  • Calculate deceleration distance without the use of electronic gear.
Mitsubishi Electronics QD73A1 — CHAPTER 5 DATA USED FOR POSITIONING diagram (page 83)
Fig. 33
Mitsubishi Electronics QD73A1 — CHAPTER 5 DATA USED FOR POSITIONING diagram (page 83)
Fig. 34

When the position where the near-point dog turns on is set near the center of Zero signals, " Setting for the movement amount after near-point dog ON" should be an integral multiple of pulses per one servomotor rotation. Then the position moved after the near-point dog ON does not overlap with Zero signal. For instance, when the number of pulses per one servomotor rotation is 2000, set 2000 pulses.

Page 84 of the Mitsubishi Electronics QD73A1 user manual — (1) Positioning pattern
Page 84 · click to enlarge
Page 84

5.4 Positioning Data

This section describes the details of positioning data.

Item Setting range Default value

0. Positioning control
0. Positioning
1. Two-phase trapezoidal positioning

control 301 Page 82, Section 5.4 (1)

Da.1

Absolute system:

Da.2

303 Page 83, Section 5.4 (2)

P1

Incremental system:

Positioning speed V1 1 to 4000000pulse/s 0pulse/s 304

305 Page 84, Section 5.4 (3)

Da.3

Absolute system:

307 Page 84, Section 5.4 (4)

Da.4

P2

Incremental system:

Positioning speed V2 1 to 4000000pulse/s 0pulse/s 308

Da.5

309 Page 84, Section 5.4 (5)

Positioning data can be set any time, but the error check is executed when a positioning start signal (Y21 to Y23) is turned on.

For details on positioning control, two-phase trapezoidal positioning control, and speed-position control switch mode,

refer to the following.

Page 185, CHAPTER 9

(1) Positioning pattern

Da.1

Select a control pattern of major positioning from "positioning control" or "two-phase trapezoidal positioning

control".

When 0 is set in b0, positioning control is specified, and when 1 is set in b0, two-phase trapezoidal positioning

control is specified.

b15 b0 b1 to

0. Positioning control 1: Two-phase trapezoidal positioning control

Values in b1 to b15 are ignored.

Show 14 more labels / short text on this page
Buffer memory · address · Reference · (decimal) · Positioning pattern · control · Positioning address · -2147483648 to 2147483647pulse · 0pulse 302 · 0 to 2147483647pulse · Positioning address · -2147483648 to 2147483647pulse · 0pulse 306 · 0 to 2147483647pulse
Page 85 of the Mitsubishi Electronics QD73A1 user manual — (c) Speed-position control switch mode
Page 85 · click to enlarge
Page 85

CHAPTER 5 DATA USED FOR POSITIONING

(2) Positioning address P1

Da.2

Set the address that is the destination of major positioning control. The setting range depends on the type of

major positioning control.

If the specified positioning address is outside the stroke range, the error "Positioning address Outside the setting

range" (error code: 30) occurs, and the positioning does not start.

(a) Absolute system

When the absolute system is selected, set an absolute address (movement amount from the OP).

Stop position (positioning start address)

Movement amount2000 Movement amount: 2000

To execute two-phase trapezoidal positioning control in the absolute system, the positioning direction from

" Positioning address P1" to " Positioning address P2" and the positioning direction from the

Da.2 Da.4

current value to " Positioning address P1" must be the same.

Da.2

If not, the error "Two-phase trapezoidal positioning address error" (error code: 31) occurs, and the two-phase

trapezoidal positioning control does not start.

(b) Incremental system

When the incremental system is selected, set movement amount from the current value.

Stop position (positioning start address)

5.4 Positioning Data

-30000 30000 (Movement amount) (Movement amount)

Moving in negative direction

Moving in positive direction

(c) Speed-position control switch mode

Set movement amount of after the shift from speed control to position control.

Show 6 more labels / short text on this page
-1000 3000 · Movement amount setting · Speed control · Position control · t · Speed-position switching command
Page 86 of the Mitsubishi Electronics QD73A1 user manual — (5) Positioning speed V2
Page 86 · click to enlarge
Page 86

(3) Positioning speed V1

Da.3

Set the command speed of major positioning control. Set a value equal to or less than " Speed limit value".

Pr.5

If the value exceeds " Speed limit value", the error "Positioning speed Outside the setting range" (error

Pr.5

code: 32) occurs, and the command speed is limited to " Speed limit value".

Pr.5

If the specified positioning speed is 0, the error "Positioning speed Outside the setting range" (error code: 32)

occurs, and the positioning does not start.

(4) Positioning address P2

Da.4

This setting is enabled only for two-phase trapezoidal positioning control.

Set the destination address of after the move to the address set to " Positioning address P1".

Da.2

For details on " Positioning address P1", refer to the following.

Da.2

Page 83, Section 5.4 (2)

(5) Positioning speed V2

Da.5

This setting is enabled only for two-phase trapezoidal positioning control.

Set the command speed to move to the address set to " Positioning address P2".

Da.4

The setting condition is the same as that of " Positioning speed V1". ( Page 84, Section 5.4 (3))

Da.3

Page 87 of the Mitsubishi Electronics QD73A1 user manual — ON
Page 87 · click to enlarge
Page 87

CHAPTER 5 DATA USED FOR POSITIONING

5.5 Monitor Data

This section describes the details of monitor data.

Buffer

memory

Item Description Default value

address

(decimal)

  • The current commanded position is stored. (different from the actual

motor position during operation)

  • The update cycle is 0.5ms.

Md.1

  • When OPR is completed, the value of " OP address" is stored.

Pr.10

  • When the current value is changed with the current value change

function, the changed value is stored. ( Page 217, Section 11.5)

  • The actual servomotor movement amount calculated based on

feedback pulses is stored as an actual current value (the number of

Md.2

feedback pulses). (Actual current value = Current feed value -

Accumulated pulses in the deviation counter)

  • The update cycle is 0.5ms.
  • When a minor error occurs, the corresponding error code is stored.
  • The latest error code is stored at all times. (When a new error occurs,

the error code is overwritten.)

Error code (ERR.1)

  • When Error reset signal (Y28) is turned on, the error code is cleared

Md.3

to 0.

For details on error codes, refer to the following.

Page 250, Section 14.3

  • When a major error occurs, the corresponding error code is stored.

5.5 Monitor Data

  • The latest error code is stored at all times. (When a new error occurs,

the error code is overwritten.)

Md.4

Error code (ERR.2)

  • When Error reset signal (Y28) is turned on, the error code is cleared

to 0.

For details on error codes, refer to the following.

Page 250, Section 14.3

  • The difference of the current feed value and actual current value is

Md.5

stored as a deviation counter value.

  • The update cycle is 0.5ms.
  • When OPR starts, "0" is stored.
  • When OPR is completed, the movement amount from the near-point

dog ON to the OPR completion is stored. (Movement amount:

Movement amount to OPR completion using near-point dog ON as

"0".) The stored value varies depending on feedback pulses input at

the OPR as shown below. When the phase A proceeds 90 degrees than phase B: positive

Md.6

ON

value When the phase B proceeds 90 degrees than phase A: negative

  • The count value is stored for both the near-point dog method and the

count method. (Use the value as a reference value for OPR

adjustment.)

Show 11 more labels / short text on this page
0pulse 100 · Current feed value · 0pulse 102 · Actual current value · Deviation counter · 0pulse 106 · value (address) · Movement amount · 0pulse 108 · after near-point dog · value
Page 88 of the Mitsubishi Electronics QD73A1 user manual — 2 1 1 0
Page 88 · click to enlarge
Page 88

Buffer

memory

Item Description Default value

address

(decimal)

0. Speed-

The on/off status of Speed-position switching command signal

(CHANGE) is stored.

Md.7

0. Speed-position switching command input OFF
1. Speed-position switching command input ON

OFF

The control mode under the speed-position control switch mode is

stored.

0. Position

Md.8

0. Position control
1. Speed control

The execution status of the zero/gain adjustment mode is stored.

0. Not in the
0. Not in the zero/gain adjustment mode

Md.9

1. In the zero/gain adjustment mode (DIP switch)
2. In the zero/gain adjustment mode (switch setting)

The status of zero/gain adjustment is stored.

0. No zero/gain adjustment
0. No zero/gain

Md.10

1. Adjusting zero
2. Adjusting gain
  • The command output speed of the operating workpiece is stored.

(May be different from the actual motor speed during operation)

Md.11

  • The update cycle is 0.5ms.

An error code is stored.

Md.12

For details on error codes, refer to the following.

Page 250, Section 14.3

The time (year: month) of error detection is stored in BCD code.

  • b15 to b8: Year
  • b7 to b0: Month

The data can be monitored in hexadecimal.

2 0 4 1

b8 b7 b0 b15

Error occurrence (Year:

0 0 0 1 0 0 1 0 1 0 0

Md.13

0000 H

0 to 9 0 to 1 0 to 9 0 to 9

1 2 0 4

00 to 99 (Year) 01 to 12 (Month)

5.5 (1)

The time (day: hour) of error detection is stored in BCD code.

  • b15 to b8: Day
  • b7 to b0: Hour

The data can be monitored in hexadecimal.

1 1 0 2

b8 b7 b0 b15

Error occurrence (Day:

Md.14

0 0 1 0 1 0 0 0 1 0

0000 H

0 to 9 0 to 2 0 to 9 0 to 3

2 1 1 0

01 to 31 (Day) 00 to 23 (Hour)

Show 24 more labels / short text on this page
position · Speed-position · switching · switching command · command input · Control mode · control 111 · Zero/gain execution · zero/gain · status · adjustment · mode · Zero/gain adjustment · adjustment 113 · status · 0pulse/s 114 · Feedrate · Error code · Month) · Monitor value · Page · 88, Section · Hour) · Monitor value
Page 89 of the Mitsubishi Electronics QD73A1 user manual — 1 5 0 8
Page 89 · click to enlarge
Page 89

CHAPTER 5 DATA USED FOR POSITIONING

Buffer

memory

Item Description Default value

address

(decimal)

The time (minute: second) of error detection is stored in BCD code.

  • b15 to b8: Minute
  • b7 to b0: Second

The data can be monitored in hexadecimal.

5 0 8 1

b8 b7 b0 b15

0 0 0 1 0 1 0 1 0 1 0 0 0

0000 H

Md.15

(MinuteSecond)

0 to 9 0 to 5 0 to 9 0 to 5

5.5 (1)

1 5 0 8

00 to 59 (Minute) 00 to 59 (Second)

  • The pointer No. for the next error record is stored. A value from 0 to

15 is stored.

Md.16

  • Even when Error reset signal (Y28) is turned on, the data is not

cleared to 0.

[When the accumulated pulse error detection function is being executed]

Md.17

The reference value that is kept in the flash ROM of the QD73A1 is

displayed.

[When the reference value is being measured]

The maximum/minimum accumulated pulse values are stored when the

pulse value 0 pulse 202

Md.18

positioning is executed in the address increasing/decreasing direction.

0 is stored.

The status of the accumulated pulse error detection function is

5.5 Monitor Data

displayed.

Md.19

0. Normal
0. Normal 204
1. Accumulated pulse error is being detected
2. Reference value is being measured

The status of the reference value measurement is displayed.

0. Unmeasured
1. Measured

Check that this area stores 1 before writing data in the flash ROM.

Md.20

0. Unmeasured 205

This area becomes 0 at the following timing.

  • When the module is started
  • When " Accumulated pulse error detection request" is set to 1

Cd.18

and the error detection starts

  • The difference of the values obtained from "Command pulse ×

CMX/CDV" and "Number of feedback pulses × Multiplication" is stored

Md.21

as a deviation counter value.

  • The update cycle is 0.5ms.
  • When OPR starts, "0" is stored.
  • When OPR is completed, the movement amount from the near-point

dog ON to the OPR completion is stored as an absolute value.

(Movement amountMovement amount to OPR completion using

Md.22

near-point dog ON as "0".)

  • The count value is stored for both the near-point dog method and the

count method. (Use the value as a reference value for OPR

adjustment.)

Show 22 more labels / short text on this page
Page · Error occurrence · 88, Section · Monitor value · Error history pointer · Maximum accumulated · 0 pulse 200 · pulse value · Minimum accumulated · [In other cases] · Accumulated pulse · error detection function · status · Reference value · measurement flag · Deviation counter · 0 pulse 116 · value (pulse) · Movement amount · 0 pulse 118 · after near-point dog · ON (absolute value)
Page 90 of the Mitsubishi Electronics QD73A1 user manual — (1) Buffer memory areas for error occurrence data
Page 90 · click to enlarge
Page 90

(1) Buffer memory areas for error occurrence data

184 Md.16

Stores the pointer number that is next to the one for the latest error history record.

Pointer No.

Pointer No. 0

120 Md.12

121 Md.13 Error occurrence (YearMonth)
122 Md.14 Error occurrence (DayHour)
123 Md.15 Error occurrence (MinuteSecond)

A set of buffer memory data is organized as an error history record with a pointer number.

Ex.

Pointer No.0 = Buffer memory addresses 120 to 123 Pointer No.1 = Buffer memory addresses 124 to 127 Pointer No.2 = Buffer memory addresses 128 to 131

Pointer No.15 = Buffer memory addresses 180 to 183 Error history records are stored from the pointer No.1 up to No.15. After 16 records are stored, the next record will be assigned the pointer No.0. (The new record replaces the older record.)

Show 6 more labels / short text on this page
Error history pointer · Error code · Error history · Item · Buffer memory · address
Page 91 of the Mitsubishi Electronics QD73A1 user manual — Buffer
Page 91 · click to enlarge
Page 91

CHAPTER 5 DATA USED FOR POSITIONING

5.6 Control Data

This section describes the details of control data.

Buffer

Item Description Setting range Default

memory

value

address

(decimal)

  • Set a new current feed value when

changing the current value.

  • Writing data in this area and setting "1" in

" Current value change request"

Cd.7

Cd.1

changes the value in " Current feed

Md.1

value".

For details on the current value change

function, refer to the following.

Page 217, Section 11.5

  • Set a new speed value when changing

speed.

  • Writing data in this area and setting "1" in

0 to " Speed limit

" Speed change request" executes

Cd.8

Pr.5

Cd.2

the speed change.

For details on the speed change function,

refer to the following.

Page 218, Section 11.6

  • Set JOG speed for JOG operation.
  • If the value exceeds " Speed limit

5.6 Control Data

Pr.5

value", the error "JOG speed Outside the

setting range" (error code41) occurs, and

the speed is limited to " Speed limit

Pr.5

value".

1 to 4000000pulse/s 0pulse/s 84

Cd.3

  • If "0" is set in this area and JOG operation is

attempted, the error "JOG speed Outside

the setting range" (error code41) occurs,

and the operation does not start.

For details on JOG operation, refer to the

following.

Page 200, CHAPTER 10

Show 8 more labels / short text on this page
-2147483648 to · 2147483647pulse 0pulse 80 · New current value · 0pulse/s 82 · New speed value · value" (pulse/s) · (Maximum 4000000 pulse/s) · JOG speed
Page 92 of the Mitsubishi Electronics QD73A1 user manual — Buffer
Page 92 · click to enlarge
Page 92

Buffer

Item Description Setting range Default

memory

value

address

(decimal)

  • Use this area to clear the accumulated

pulses in the deviation counter.

  • Write "1" to clear the counter. If a value

other than "1" is set, the command is

ignored.

  • After the deviation counter was cleared, "0"

is stored automatically.

  • To start positioning after the deviation

counter was cleared, check that this area

stores "0" and no error is detected before

the start.

  • When the deviation counter is cleared,
1. Clear the deviation

Cd.4

" Actual current value" changes to the

Md.2

value in " Current feed value".

Md.1

  • Data cannot be written while BUSY signal

(X14) is on. Check that BUSY signal (X14)

is off before writing data. If data writing is

attempted while BUSY signal (X14) is on,

the error "Deviation counter clear error"

(error code: 114) occurs.

For details on the deviation counter clear

function, refer to the following.

Page 220, Section 11.7

  • Set pulse amount to adjust gain with

specific accumulated pulse amount.

pulse setting" in the switch

  • This setting is enabled only in the zero/gain

setting.

adjustment mode.

  • Use this area when the default value or one

range (Unit:

of the selections 1 to 4 is set in

"Accumulated pulse setting" in the switch

Selection 1 -3700 to

setting. (When one of the selections 5 to 8 is

Cd.5 Cd.9

set, use " Analog output adjustment

Selection 2 -7400 to

area 2".)

  • If the setting is outside the setting range, the

Selection 3 -11100 to

error "Analog output adjustment area 1

Outside the setting range" (error code: 125)

occurs.

For details on zero/gain adjustment, refer to

the following.

Page 59, Section 4.5

  • Set this area to change movement amount

of after a switchover to position control in

the speed-position control switch mode.

  • The set value is reflected at the input of

Speed-position switching command signal

1 to 2147483647pulse 0pulse 88

(CHANGE).

Cd.6

  • The setting is cleared to 0 when the next

operation starts.

For details on the Speed-position control

switch mode, refer to the following.

Page 195, Section 9.6.2

Show 15 more labels / short text on this page
Deviation counter clear · counter 0 86 · command · Depends on "Accumulated · Setting · Accumulated · pulse setting · pulse) · Analog output · adjustment area 1 · Default value · -14800 to · or selection · New speed-position · movement amount
Page 93 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 5 DATA USED FOR POSITIONING
Page 93 · click to enlarge
Page 93

CHAPTER 5 DATA USED FOR POSITIONING

Buffer

Item Description Setting range Default

memory

value

address

(decimal)

  • Use this area to request a current value

change.

  • After setting " New current value", set

Cd.1

"1" in this area. If a value other than "1" is

set, the setting is ignored.

  • After the current value change was

accepted, "0" is stored automatically.

  • A current value change cannot be

requested while BUSY signal (X14) is on.

1. Change the current value 0 90

Cd.7

Check that BUSY signal (X14) is off before

requesting a current value change.

  • If a current value change is requested while

BUSY signal (X14) is on, the error "Current

value change error" (error code110)

occurs.

For details on the current value change

function, refer to the following.

Page 217, Section 11.5

  • Use this area to request a speed change.
  • After setting " New speed value", set

Cd.2

"1" in this area. If a value other than "1" is

set, the setting is ignored.

  • After the speed change was accepted, "0" is

stored automatically.

  • If a speed change is requested with

" New speed value" exceeding

Cd.2

5.6 Control Data

1. Change speed 0 91

Cd.8

" Speed limit value", the error "New

Pr.5

speed value Outside the setting range"

(error code40) occurs, and the speed after

the change is limited to " Speed limit

Pr.5

value".

For details on the speed change function,

refer to the following.

Page 218, Section 11.6

  • Set pulse amount to adjust gain with

specific accumulated pulse amount.

pulse setting" in the switch

  • This setting is enabled only in the zero/gain

setting.

adjustment mode.

  • Use this area when one of the selections 5

range (Unit:

to 8 is set in "Accumulated pulse setting" in

the switch setting. (When one of the

Selection 5 -37000 to

selections 1 to 4 is set, use " Analog

Cd.5

Cd.9

output adjustment area 1".)

Selection 6 -74000 to

  • If the setting is outside the setting range, the

error "Analog output adjustment area 2

Selection 7 -111000 to

Outside the setting range" (error code: 126)

occurs.

For details on zero/gain adjustment, refer to

Selection 8 -148000 to

the following.

Page 59, Section 4.5

Show 10 more labels / short text on this page
Current value change · request · Speed change request · Depends on "Accumulated · Setting · Accumulated · pulse setting · pulse) · Analog output · adjustment area 2
Page 94 of the Mitsubishi Electronics QD73A1 user manual — Buffer
Page 94 · click to enlarge
Page 94

Buffer

Item Description Setting range Default

memory

value

address

(decimal)

  • Specify "zero adjustment" or "gain

adjustment".

  • When zero/gain adjustment is performed

using switches on the front of the QD73A1,

the set value is ignored.

1. Zero adjustment
  • If a value other than 0, 1, and 2 is set, the
2. Gain adjustment 0 94

Cd.10

error "Zero/gain adjustment setting error"

(error code: 123) occurs.

For details on zero/gain adjustment, refer to

the following.

Page 59, Section 4.5

  • Use this area to set adjustment amount of

the analog output value during zero/gain

adjustment.

  • The analog output value changes by the

adjustment amount when Set value change

request signal (Y1C) is turned on and off.

Ex.

When 1000 is set, the analog output

value can be adjusted by approximately

Cd.11

-3000 to 3000 0 95

  • When zero/gain adjustment is performed

using switches on the front of the QD73A1,

the set value is ignored.

  • If the setting is outside the setting range, the

error "Zero/gain adjustment value error"

(error code: 124) occurs.

For details on zero/gain adjustment, refer to

the following.

Page 59, Section 4.5

  • Use this area to restore the zero adjustment

value and gain adjustment value to the

factory default.

  • This setting is enabled only in the zero/gain
1. Restore the zero/gain

Cd.12

adjustment mode.

adjustment value 0 96

  • If a value other than "1" is set, the setting is

ignored.

  • After the zero/gain adjustment value was

restored, "0" is stored automatically.

Show 8 more labels / short text on this page
Zero/gain adjustment · specification · Zero/gain adjustment · value specification · Factory default · zero/gain adjustment · value restoration · request
Page 95 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 5 DATA USED FOR POSITIONING
Page 95 · click to enlarge
Page 95

CHAPTER 5 DATA USED FOR POSITIONING

Buffer

Item Description Setting range Default

memory

value

address

(decimal)

The difference between the reference value

(maximum value) and the judgment value

(alert output accumulated pulses (maximum

value)) is set.

The relation between this setting and the

judgment value is as follows.

[If " Accumulated pulse setting value

Cd.17

selection" is set to 0]

  • If " Accumulated

Cd.17

Alert output accumulated pulses (maximum

selection" is set to 0:

value) = reference value (maximum value) +

1 to 148000 pulse

Cd.13

Alert output accumulated pulse setting

  • If " Accumulated

Cd.17

Cd.13

selection" is set to 1:

[If " Accumulated pulse setting value

Cd.17

selection" is set to 1]

(× 10 -3Last three digits

are the value after the

Alert output accumulated pulses (maximum

decimal point.)

value) = reference value (maximum value) +

( Alert output accumulated pulse setting

Cd.13

value (maximum value) - 1000) × reference

value (maximum value) 1000

For details on the accumulated pulse error

detection function, refer to the following.

5.6 Control Data

Page 223, Section 11.9

Show 8 more labels / short text on this page
pulse setting value · Alert output · accumulated pulse · value (maximum value) · pulse setting value · setting value (maximum · value) · 1000 to 50000
Page 96 of the Mitsubishi Electronics QD73A1 user manual — Buffer
Page 96 · click to enlarge
Page 96

Buffer

Item Description Setting range Default

memory

value

address

(decimal)

The difference between the reference value

(maximum value) and the judgment value

(immediate stop accumulated pulses

(maximum value)) is set.

The relation between this setting and the

judgment value is as follows.

[If " Accumulated pulse setting value

Cd.17

selection" is set to 0]

  • If " Accumulated

Cd.17

Immediate stop accumulated pulses

(maximum value) = reference value

selection" is set to 0:

(maximum value) + Immediate stop

Cd.14

1 to 148000 pulse

accumulated pulse setting value (maximum

  • If " Accumulated

Cd.17

Cd.14

selection" is set to 1:

[If " Accumulated pulse setting value

Cd.17

selection" is set to 1]

(× 10 -3Last three digits

are the value after the

Immediate stop accumulated pulses

decimal point.)

(maximum value) = reference value

(maximum value) + ( Immediate stop

Cd.14

accumulated pulse setting value (maximum

value) - 1000) × reference value (maximum

For details on the accumulated pulse error

detection function, refer to the following.

Page 223, Section 11.9

Show 9 more labels / short text on this page
pulse setting value · Immediate stop · accumulated pulse · value) · pulse setting value · setting value (maximum · value) · 1000 to 50000 · value) 1000
Page 97 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 5 DATA USED FOR POSITIONING
Page 97 · click to enlarge
Page 97

CHAPTER 5 DATA USED FOR POSITIONING

Buffer

Item Description Setting range Default

memory

value

address

(decimal)

The difference between the reference value

(minimum value) and the judgment value (alert

output accumulated pulses (minimum value))

is set.

The relation between this setting and the

judgment value is as follows.

[If " Accumulated pulse setting value

Cd.17

selection" is set to 0]

  • If " Accumulated

Cd.17

Alert output accumulated pulses (minimum

selection" is set to 0:

value) = reference value (minimum value) +

-148000 to -1 pulse

Cd.15

Alert output accumulated pulse setting

  • If " Accumulated

Cd.17

Cd.15

selection" is set to 1:

[If " Accumulated pulse setting value

Cd.17

selection" is set to 1]

(× 10 -3Last three digits

are the value after the

Alert output accumulated pulses (minimum

decimal point.)

value) = reference value (minimum value) +

( Alert output accumulated pulse setting

Cd.15

value (minimum value) - 1000) × reference

value (minimum value) 1000

For details on the accumulated pulse error

detection function, refer to the following.

5.6 Control Data

Page 223, Section 11.9

Show 8 more labels / short text on this page
pulse setting value · Alert output · accumulated pulse · value (minimum value) · pulse setting value · setting value (minimum · value) · 1000 to 50000
Page 98 of the Mitsubishi Electronics QD73A1 user manual — Buffer
Page 98 · click to enlarge
Page 98

Buffer

Item Description Setting range Default

memory

value

address

(decimal)

The difference between the reference value

(minimum value) and the judgment value

(immediate stop accumulated pulses

(minimum value)) is set.

The relation between this setting and the

judgment value is as follows.

[If " Accumulated pulse setting value

Cd.17

selection" is set to 0]

  • If " Accumulated

Cd.17

Immediate stop accumulated pulses

selection" is set to 0:

(minimum value) = reference value (minimum

-148000 to -1 pulse

value) + Immediate stop accumulated

Cd.16

  • If " Accumulated

Cd.17

pulse setting value (minimum value)

Cd.16

selection" is set to 1:

[If " Accumulated pulse setting value

Cd.17

selection" is set to 1]

(× 10 -3Last three digits

are the value after the

Immediate stop accumulated pulses

decimal point.)

(minimum value) = reference value (minimum

value) + ( Immediate stop accumulated

Cd.16

pulse setting value (minimum value) - 1000) ×

reference value (minimum value) 1000

For details on the accumulated pulse error

detection function, refer to the following.

Page 223, Section 11.9

  • The setting unit for " Alert output

Cd.13

accumulated pulse setting value (maximum

value)" to " Immediate stop

Cd.16

accumulated pulse setting value (minimum

value)" is selected.

  • If a value other than 0 and 1 is set, the value

is regarded as 0.

0. Set
  • If this area is set to 1 and the
0. Set with pulse

Cd.17

maximum/minimum reference values are

1. Set with magnification

set to 0, the error "Accumulated pulse error

undetectable" (error code131) occurs and

the accumulated pulse error detection

function does not operate.

For details on the accumulated pulse error

detection function, refer to the following.

Page 223, Section 11.9

Show 11 more labels / short text on this page
pulse setting value · Immediate stop · accumulated pulse · pulse setting value · setting value (minimum · value) · 1000 to 50000 · Accumulated pulse · with · setting value selection · pulse
Page 99 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 5 DATA USED FOR POSITIONING
Page 99 · click to enlarge
Page 99

CHAPTER 5 DATA USED FOR POSITIONING

Buffer

Item Description Setting range Default

memory

value

address

(decimal)

  • Use this area to start/stop the accumulated

pulse error detection function.

  • While this area is set to 1, the accumulated

pulse error detection function is executed.

However, if the reference value has never

been measured, the error "Accumulated

pulse error undetectable" (error code131)

occurs and the function does not operate.

  • If a value other than 0 and 1 is set, the value

is regarded as 0.

0. No request
0. No

Cd.18 Cd.19

  • If " Measurement start request" is set
1. Requested

to 1, the function does not operate even if

this area is set to 1. (This request is ignored

and after " Measurement start

Cd.19

request" is set to 0, the function is

executed.)

For details on the accumulated pulse error

detection function, refer to the following.

Page 223, Section 11.9

  • Use this area to measure accumulated

pulses used as the reference value to detect

an error.

  • While this area is set to 1, the

values are measured.

5.6 Control Data

  • If a value other than 0 and 1 is set, the value

is regarded as 0.

  • If " Accumulated pulse error detection

Cd.18

0. No request
0. No

request" is set to 1, the value is not

Cd.19

1. Requested

measured even if this area is set to 1. (This

request is ignored and after

" Accumulated pulse error detection

Cd.18

request" is set to 0, the function is

executed.)

For details on the accumulated pulse error

detection function, refer to the following.

Page 223, Section 11.9

Show 7 more labels / short text on this page
Accumulated pulse error · request 409 · detection request · maximum/minimum accumulated pulse · Measurement start · request 410 · request
Page 100 of the Mitsubishi Electronics QD73A1 user manual — Buffer
Page 100 · click to enlarge
Page 100

Buffer

Item Description Setting range Default

memory

value

address

(decimal)

  • Use this area to save the measured

reference value in the flash ROM of the

QD73A1.

  • When this area setting is changed to 1, the

measured reference value is saved in the

flash ROM.

  • When " Reference value

Md.20

measurement flag" is set to 1, the value is

written to the flash ROM. If

" Reference value measurement flag"

Md.20

0. No request
0. No

Cd.20

is set to the value other than 1, the error

1. Requested

"Reference value write error" (error code:

132. occurs and the value is not written.
  • The QD73A1 set this area to 0 when the

value saving in the flash ROM is completed.

This process is the same when an error

occurs and the value is not written.

For details on the accumulated pulse error

detection function, refer to the following.

Page 223, Section 11.9

Reference value write · request 411 · request

Page 101 of the Mitsubishi Electronics QD73A1 user manual — Item Description
Page 101 · click to enlarge
Page 101

CHAPTER 6 VARIOUS SETTINGS

CHAPTER 6 VARIOUS SETTINGS

This chapter describes setting procedures of the QD73A1.

  • After writing the contents of the new module, parameter settings, and auto refresh settings into the CPU module, reset the CPU module and switch its status as STOP RUN STOP RUN, or turn off and on the power supply to activate the settings.
  • After writing the contents of the switch settings, reset the CPU module or turn off and on the power supply to activate the settings.

6.1 Adding a Module

(1) Addition procedure

Open the "New Module" window.

Project window [Intelligent Function Module] Right-click [New Module...]

Mitsubishi Electronics QD73A1 — (1) Addition procedure diagram (page 101)
Fig. 35 · (1) Addition procedure

6.1 Adding a Module

Item Description

Module Type Set "QD70 Type Positioning Module".

Module Name Set the name of the module to mount.

Base No. Set the base unit where the module is mounted.

Mounted Slot No. Set the slot No. where the module is mounted.

The start I/O number (hexadecimal) of the module is set, according to the mounted

slot No. Any start I/O number can be set.

Title setting Title Set any title.

Show 6 more labels / short text on this page
Module · Selection · Mount · Position · Specify start XY · address
Page 102 of the Mitsubishi Electronics QD73A1 user manual — Item Description Setting value Default value Reference
Page 102 · click to enlarge
Page 102

6.2 Switch Setting

Configure settings related to the drive unit and encoder that are connected to the QD73A1.

(1) Setting method

Open the "Switch Setting" window.

Project window [Intelligent Function Module] Module name [Switch Setting]

Mitsubishi Electronics QD73A1 — (1) Setting method diagram (page 102)
Fig. 36 · (1) Setting method

Item Description Setting value Default value Reference

  • Positive voltage is output when the

Set the rotation direction in which

positioning address increases.

positioning addresses increase.

  • Negative voltage is output when the

Section 6.2.1

positioning address increases.

address increases.

  • -3700 to 3700 pulse [Selection 1]
  • -7400 to 7400 pulse [Selection 2]
  • -11100 to 11100 pulse [Selection 3]

Select the maximum accumulated

  • -14800 to 14800 pulse [Selection 4]

pulse amount that can be counted

Section 6.2.2

in the deviation counter.

  • -37000 to 37000 pulse [Selection 5]
  • -74000 to 74000 pulse [Selection 6]
  • -111000 to 111000 pulse [Selection 7]
  • -148000 to 148000 pulse [Selection 8]

Set the multiplication rate of

feedback pulses from the pulse

Section 6.2.3

generator (PLG).

  • 1/2

Set the direction in which OPR is

  • Reverse direction (address decreasing)

executed.

  • Forward direction (address increasing)

Section 6.2.4

setting Select an OPR method. • Near-point dog method

  • Count method

Section 6.2.5

Select an encoder output type

  • Open collector output

from open collector, TTL, or

  • TTL output

Section 4.6.2

differential output.

  • Differential output

Set resolution of analog voltage

  • 12-bit resolution

12-bit resolution Page 105,

to be output as a speed

  • 14-bit resolution

Section 6.2.7

command.

  • 16-bit resolution
Show 37 more labels / short text on this page
Positive voltage is · Rotation · output when the · Page 101, · direction · positioning · setting · -14800 to 14800 · Accumulated · Page 102, · pulse · pulse setting · [Selection 4] · • 4 · Multiplication · • 2 · 4 Page 104, · setting · • 1 · Reverse direction · OPR direction · Page 104, · (address · setting · decreasing) · OPR method · Near-point dog · Page 104, · method · Encoder I/F · Open collector · Page 66, · setting · output · Analog voltage · resolution · setting
Page 103 of the Mitsubishi Electronics QD73A1 user manual — 6.2.1 Rotation direction setting
Page 103 · click to enlarge
Page 103

CHAPTER 6 VARIOUS SETTINGS

Item Description Setting value Default value Reference

Set whether to add or subtract the

  • Add when the phase A proceeds 90

feedback pulses to/from the

degrees than phase B.

deviation counter when the phase

  • Subtract when the phase A proceeds 90

Section 6.2.8

A of feedback pulse proceeds 90

degrees than phase B.

phase B.

degrees than phase B.

  • Clear the deviation counter when the servo

Set whether to clear the deviation

ready signal is OFF.

counter when Servo READY

  • Do not clear the deviation counter when the

Section 6.2.9

signal turns off.

servo ready signal is OFF.

is OFF.

Select the zero/gain adjustment

  • Normal mode
  • Zero/gain adjustment mode Normal mode

Section 4.5

mode or the normal mode.

6.2.1 Rotation direction setting

Set the direction in which positioning addresses increase.

The rotation direction of a motor depends on the polarity of the voltage to be applied to the servo amplifier.

For details, refer to the manual for the servo amplifier.

For connection between the QD73A1 and an encoder, refer to the following.

Page 66, Section 4.6.2

6.2 Switch Setting 6.2.1 Rotation direction setting

Show 21 more labels / short text on this page
Feed back · Add when the · pulse · phase A proceeds · Page 106, · addition/sub- · 90 degrees than · traction setting · Clear the deviation · Deviation · counter when the · Page 107, · counter clear · servo ready signal · setting · Zero/gain · Page 62, · adjustment · mode/Normal · (4) (b) · mode setting
Page 104 of the Mitsubishi Electronics QD73A1 user manual — Position loop gain value Description
Page 104 · click to enlarge
Page 104

6.2.2 Accumulated pulse setting

Select the maximum accumulated pulse amount that can be counted in the deviation counter.

(1) Calculating accumulated pulse amount

When a servomotor is used, "maximum accumulated pulse amount" obtained by the following formula generates.

Position loop gain (s-1)

Configure this setting so that "maximum accumulated pulse amount" stays within the accumulated pulse setting

range.

(a) Position loop gain

Position loop gain is a parameter to be set on the servomotor side. It effects operation in case of a servomotor

stop and pulse amount in the deviation counter during operation.

Position loop gain value Description

Low Accumulated amount is large, and adjustment time at a stop becomes long.

High Overshoot becomes large at a stop, or vibration tends to occur during a stop.

Position loop gain is adjusted to 20 to 30s-1 normally. Make fine adjustment if necessary.

For details, refer to the manual for the servomotor.

Maximum accumulated · Speed command (pulse/s) · pulse amount =

Page 105 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 6 VARIOUS SETTINGS
Page 105 · click to enlarge
Page 105

CHAPTER 6 VARIOUS SETTINGS

(b) Accumulated pulse amount and analog output voltage from the QD73A1

The analog output voltage from the QD73A1 is controlled in proportion to accumulated pulse amount.

Selection 2 Selection 3 Selection 4 Analog output voltage Gain adjustment value

3700* 3480 6960 7400* 10440 11100* 13920 14800*

If the accumulated pulse exceeds the amount marked *, an excessive error occurs.

Selection 6 Selection 7 Selection 8 Analog output voltage

6.2 Switch Setting 6.2.2 Accumulated pulse setting

34800 69600 104400 139200

37000* 74000* 111000* 148000*

If the accumulated pulse exceeds the amount marked *, an excessive error occurs.

The following is an example of selecting an option in "Accumulated pulse setting".

Ex. Maximum speed4Mpulse/s, position loop gain: 30s -1

pulse = = Maximum speed

If the number of accumulated pulses is 133333, "-148000 to 148000 pulse" should be selected in

"Accumulated pulse setting" so that analog output voltage will not be saturated.

Show 14 more labels / short text on this page
Selection 1 · Accumulated pulse · -3480 -6960 · Gain adjustment value · Gain adjustment value · Selection 5 · Accumulated pulse · -69600 -34800 · Gain adjustment value · 4000000 · Accumulated · = · 30 133333 pulses · Position loop gain
Page 106 of the Mitsubishi Electronics QD73A1 user manual — 6.2.5 OPR method setting
Page 106 · click to enlarge
Page 106

(2) Excessive error

If accumulated pulse amount exceeds an upper limit value (values marked * in Page 103, Section 6.2.2 (1) (b)),

an excessive error occurs and the following conditions occur in the system.

  • Excessive error signal (X17): ON
  • Analog output voltage: 0V
  • Accumulated pulses: Reset to 0
  • Servo ON signal (SVON): OFF

To reset an excessive error, turn off and on PLC READY signal (Y2D).

6.2.3 Multiplication setting

Set the multiplication rate of feedback pulses from the pulse generator (PLG).

This setting multiplies the feedback pulse count by 4, 2, 1, or 1/2. Use this setting to change movement amount per

pulse by 1/4, 1/2, 1, or 2.

Mitsubishi Electronics QD73A1 — 6.2.3 Multiplication setting diagram (page 106)
Fig. 37 · 6.2.3 Multiplication setting

6.2.4 OPR direction setting

Set the direction in which OPR is executed.

For OPR control, refer to the following.

Page 178, CHAPTER 8

Mitsubishi Electronics QD73A1 — 6.2.4 OPR direction setting diagram (page 106)
Fig. 38 · 6.2.4 OPR direction setting

OPR (Original Point Return) is controlled by two kinds of data: OPR direction and OPR speed. Deceleration starts when the near-point dog

turns on. If an incorrect OPR direction is set, motion control may continue without deceleration. To prevent machine damage caused by

this, configure an interlock circuit external to the programmable controller.

6.2.5 OPR method setting

Select an OPR method.

For OPR control, refer to the following.

Page 178, CHAPTER 8

Page 107 of the Mitsubishi Electronics QD73A1 user manual — 6.2.7 Analog voltage resolution setting
Page 107 · click to enlarge
Page 107

CHAPTER 6 VARIOUS SETTINGS

6.2.6 Encoder I/F setting

Select an encoder output type from open collector, TTL, or differential output.

For connection between the QD73A1 and an encoder, refer to the following.

Page 66, Section 4.6.2

6.2.7 Analog voltage resolution setting

Set resolution of analog voltage to be output as a speed command.

The default value of "Analog voltage resolution setting" is "12-bit resolution". When the analog voltage resolution of the connected drive unit is higher than 12 bits and the motor rotates even with a tiny voltage, the resolution can be set higher (14 bits or 16 bits). In that way, fine control can be achieved.

6.2 Switch Setting 6.2.6 Encoder I/F setting

Page 108 of the Mitsubishi Electronics QD73A1 user manual — 6.2.8 Feedback pulse addition/subtraction setting
Page 108 · click to enlarge
Page 108

6.2.8 Feedback pulse addition/subtraction setting

Set whether to add or subtract the feedback pulses to/from the deviation counter when the phase A of feedback pulse

proceeds 90 degrees than phase B.

This setting becomes enabled only when "1: Negative voltage is output when the positioning address increases." is set

for "Rotation direction setting" in the switch setting. If "0: Positive voltage is output when the positioning address

increases." is set, the setting value of "Feed back pulse addition/subtraction setting" is ignored.

For the connection between the QD73A1 and the encoder, refer to the following.

Page 66, Section 4.6.2

When the feedback pulses are input, the feedback pulses are added or subtracted to/from the deviation counter (when

"Multiplication setting" is 4).

(1) When a feedback pulse whose phase A is ahead of phase B by 90° is input

1. When "0: Add when the phase A proceeds 90 degrees than phase B." is set

0 1 2 3 4 5...

2. When "1: Subtract when the phase A proceeds 90 degrees than phase B." is set

0 -1 -2 -3 -4 -5...

(2) When a feedback pulse whose phase B is ahead of phase A by 90° is input

1. When "0: Add when the phase A proceeds 90 degrees than phase B." is set

0 -1 -2 -3 -4 -5...

2. When "1: Subtract when the phase A proceeds 90 degrees than phase B." is set

0 1 2 3 4 5...

Show 12 more labels / short text on this page
Phase-A feedback pulse · Phase-B feedback pulse · Deviation counter value · Added · Deviation counter value · Subtracted · Phase-A feedback pulse · Phase-B feedback pulse · Deviation counter value · Subtracted · Deviation counter value · Added
Page 109 of the Mitsubishi Electronics QD73A1 user manual — OFF
Page 109 · click to enlarge
Page 109

CHAPTER 6 VARIOUS SETTINGS

6.2.9 Deviation counter clear setting

Set whether to clear the deviation counter when Servo READY signal turns off.

If "0: Clear the deviation counter when the servo ready signal is OFF." is set, the deviation counter is cleared and OPR

request signal turns on when Servo READY signal turns off. After Servo READY signal is turned on, execute OPR

before executing the positioning control.

If "1: Do not clear the deviation counter when the servo ready signal is OFF." is set, the deviation counter is not cleared

when Servo READY signal turns off. OPR request signal does not turn on as well. When turning on Servo READY

signal after that, ensure the system safety in advance because turning on the signal may cause a sudden rotation of

the motor.

(1) When "0Clear the deviation counter when the servo ready signal is OFF." is set

The current feed value and the position of the controlled object may not match. Execute the OPR.

0 Actual current value

OPR request signal (X12)

6.2 Switch Setting 6.2.9 Deviation counter clear setting

(2) When "1: Do not clear the deviation counter when the servo ready signal is OFF." is set

Current feed value 0

0 Actual current value

0 5 0 5→0

2 3 4 1

OPR request signal (X12)

OFF

Analog output 0V 5) 4) 3) 2) 1) 0V 5)→1)

1. to 5): Voltage corresponds to the deviation counter value is output.

The motor may rotate suddenly. Ensure the safety before turning on Servo READY signal.

1): Voltage corresponds to one pulse is output.

Show 8 more labels / short text on this page
Servo READY signal · Feedback pulse · Current feed value · Deviation counter value · Analog output 0V · -2 -3 -4 · 0 -5→0 · Deviation counter value
Page 110 of the Mitsubishi Electronics QD73A1 user manual — Setting item Default value Reference
Page 110 · click to enlarge
Page 110

6.3 Parameter Setting

Set positioning parameters and OPR parameters.

Setting parameters on the screen omits the parameter setting in a sequence program.

(1) Setting method

Open the "Parameter" window.

1. Start "Parameter" in the project window.

Project window [Intelligent Function Module] Module name [Parameter]

Mitsubishi Electronics QD73A1 — (1) Setting method diagram (page 110)
Fig. 39 · (1) Setting method
2. Double-click the item to change the setting, and input the setting value.
  • Items to input from the pull-down list

For "Positioning mode", double-click the item to display the pull-down list. Select an option.

  • Items to input from the text box

Double-click the item to set, and input the setting value.

For details on setting values, refer to the following.

Setting item Default value Reference

Stroke limit upper limit 2147483647 pulse Page 76, Section 5.2 (1) Stroke limit lower limit 0 pulse

Numerator of command pulse

multiplication for electronic gear 1

Page 77, Section 5.2 (2) Denominator of command pulse

multiplication for electronic gear 1

Speed limit value 200000 pulse/s Page 77, Section 5.2 (3)

Acceleration time 300 ms Page 78, Section 5.2 (4) Deceleration time 300 ms

In-position range 5 pulse Page 78, Section 5.2 (5)

Positioning mode 0Position control mode Page 78, Section 5.2 (6)

OP address 0 pulse Page 79, Section 5.3 (1)

OPR speed 10000 pulse/s Page 79, Section 5.3 (2)

Creep speed 1000 pulse/s Page 80, Section 5.3 (3)

Setting for the movement amount after

near-point dog ON 75 pulse Page 81, Section 5.3 (4)

Fixed parameter · Variable parameter · OPR parameter

Page 111 of the Mitsubishi Electronics QD73A1 user manual — Setting item Default value Reference
Page 111 · click to enlarge
Page 111

CHAPTER 6 VARIOUS SETTINGS

6.4 Positioning Data Setting

Set positioning data.

Setting positioning data on the screen omits the positioning data setting in a sequence program.

(1) Setting method

Open the "Positioning_Axis_#1_Data" window.

1. Start "Positioning_Axis_#1_Data" in the project window.

Project window [Intelligent Function Module] Module name [Positioning_Axis_#1_Data]

Mitsubishi Electronics QD73A1 — (1) Setting method diagram (page 111)
Fig. 40 · (1) Setting method
2. Double-click "Positioning pattern", and set a positioning pattern. 3. Double -click items other than "Positioning pattern", and input setting values.

For details on setting values, refer to the following.

Setting item Default value Reference

Page 82, Section 5.4 (1)

Positioning address P1 Page 83, Section 5.4 (2)

Positioning speed V1 Page 84, Section 5.4 (3)

Positioning address P2 Page 84, Section 5.4 (4)

6.4 Positioning Data Setting

Positioning speed V2 Page 84, Section 5.4 (5)

Positioning pattern · None (empty)

Page 112 of the Mitsubishi Electronics QD73A1 user manual — (1) Setting method
Page 112 · click to enlarge
Page 112

6.5 Auto Refresh

This function transfers data in the buffer memory to specified devices.

The auto refresh setting omits data reading/writing through a program.

(1) Setting method

Open the "Auto_Refresh" window.

1. Start "Auto_Refresh" in the project window.

Project window [Intelligent Function Module] Module name

[Auto_Refresh] 2. Click the item to set, and input the destination device for auto refresh.

Mitsubishi Electronics QD73A1 — (1) Setting method diagram (page 112)
Fig. 41 · (1) Setting method
Page 113 of the Mitsubishi Electronics QD73A1 user manual — (8) JOG speed
Page 113 · click to enlarge
Page 113

CHAPTER 7 PROGRAMMING

CHAPTER 7 PROGRAMMING

This chapter describes sequence programs of the QD73A1.

When applying the program examples introduced in this chapter to the actual system, ensure the applicability and

confirm that they will not cause system control problems.

7.1 Precautions on Programming

(1) At power-on and operation start

At a power-on or operation start, execute OPR to confirm the original point (OP). When an OPR request is

issued, take the OPR into consideration.

(2) Near-point dog signal

Use a high-performance near-point dog signal. If Near-point dog signal is not input upon OPR, the workpiece

continues to move at the OPR speed.

(3) Measures against an overrun

By setting a stroke limit upper limit and lower limit of the QD73A1, an overrun can be prevented.

limit switch" to ensure the safety of the entire system. It is recommended to establish an external circuit through

which the motor's power turns off when a limit switch turns on.

7.1 Precautions on Programming

(4) Stroke limit upper limit value/lower limit value

Check that proper values are set in " Stroke limit upper limit" and " Stroke limit lower limit".

Pr.1 Pr.2

(5) Emergency stop signal

Establish an emergency stop circuit outside the programmable controllers.

(6) When errors are checked in a sequence program

Turn off PLC READY signal (Y2D) at error detection.

(7) Speed limit value

Pr.5

Check that a proper value is set.

(8) JOG speed

Cd.3

Do not set a large value at the beginning; start operation at lower speed.

Page 114 of the Mitsubishi Electronics QD73A1 user manual — (9) Communication with the QD73A1
Page 114 · click to enlarge
Page 114

(9) Communication with the QD73A1

There are following ways of communication with the QD73A1 using a sequence program.

  • Communication using intelligent function module devices
  • Communication using the FROM/TO instruction

The sequence programs introduced in this chapter uses intelligent function module devices. When using the

FROM/TO instruction, change the sequence program as shown below.

When an intelligent function module device is used as the destination side in a circuit using the BMOVP instruction, change

the instruction to the TOP instruction.

Mitsubishi Electronics QD73A1 — (9) Communication with the QD73A1 diagram (page 114)
Fig. 42 · (9) Communication with the QD73A1

When an intelligent function module device is used in a circuit using a comparison instruction, change the instruction to the

FROM instruction and a comparison instruction.

Mitsubishi Electronics QD73A1 — (9) Communication with the QD73A1 diagram (page 114)
Fig. 43 · (9) Communication with the QD73A1

For intelligent function module devices, refer to the following.

The user's manual (Function Explanation, Program Fundamentals) for the CPU module used.

For details on the instructions used in programs in this chapter, refer to the following.

MELSEC-Q/L Programming Manual (Common Instruction)

Page 115 of the Mitsubishi Electronics QD73A1 user manual — (b) When the first half (slot) is "Empty 0 point"
Page 115 · click to enlarge
Page 115

CHAPTER 7 PROGRAMMING

(10)I/O number assignment for the QD73A1

The QD73A1 occupies 48 I/O points of 2 slots.

(a) Default I/O number assignment

Set the first half to "Empty 16 points" and the second half to "Intelligent 32 points" in GX Works2.

Mitsubishi Electronics QD73A1 — (a) Default I/O number assignment diagram (page 115)
Fig. 44 · (a) Default I/O number assignment

When executing the FROM/TO instruction on the QD73A1, use the I/O number assigned to the second half (slot)

of the QD73A1.

(b) When the first half (slot) is "Empty 0 point"

At the I/O assignment in GX Works2, the 16 points in the first half can be saved by setting the first half to

"Empty 0 point".

Mitsubishi Electronics QD73A1 — (b) When the first half (slot) is "Empty 0 point" diagram (page 115)
Fig. 45 · (b) When the first half (slot) is "Empty 0 point"

When executing the FROM/TO instruction on the QD73A1, use the I/O number assigned to the second half

(slot) of the QD73A1.

7.1 Precautions on Programming

Page 116 of the Mitsubishi Electronics QD73A1 user manual — OPR
Page 116 · click to enlarge
Page 116

7.2 Programs for Positioning

Follow the procedure below when creating programs that execute positioning using the QD73A1.

Procedure Program Reference

Page 117, Section 7.3.1

Create a program for parameter setting.

Page 149, Section 7.4.1

OPR

Create a program for one of the following.

Page 119, Section 7.3.2

  • Near-point dog method

Page 151, Section 7.4.2

  • Count method

Create programs for the following depending on the control to be

Page 125, Section 7.3.3

executed.

Page 133, Section 7.3.4

  • Positioning control

Page 135, Section 7.3.5

  • Two-phase trapezoidal positioning control

Page 157, Section 7.4.3

  • Speed-position control switch mode

Page 167, Section 7.4.4

  • Speed control operation

Page 170, Section 7.4.5

  • Fixed-feed operation
  • JOG operation

Create programs for the following depending on the control to be

executed.

Page 137, Section 7.3.6

  • Current value change

Page 172, Section 7.4.6

  • Speed change
  • Deviation counter clear

Page 141, Section 7.3.7

Create a program for stopping control.

Page 177, Section 7.4.7

Show 4 more labels / short text on this page
1 Parameter setting · Start program · Sub program · 5 Stop program
Page 117 of the Mitsubishi Electronics QD73A1 user manual — Item Setting value
Page 117 · click to enlarge
Page 117

CHAPTER 7 PROGRAMMING

7.3 When Using the Module in a Standard System Configuration

This section introduces program examples where the following system configuration applies.

(1) System configuration

Mitsubishi Electronics QD73A1 — (1) System configuration diagram (page 117)
Fig. 46 · (1) System configuration
QD73A1 First halfX/Y0 to X/YF (Empty 16 points)

7.3 When Using the Module in a Standard System Configuration

Item Setting value

Rotation direction setting Set this item according to the system to be used.

Accumulated pulse setting Set this item according to the system to be used.

Multiplication setting Set this item according to the system to be used.

OPR direction setting Set this item according to the system to be used.

OPR method setting Set the near-point dog method or the count method.

Encoder I/F setting Set this item according to the system to be used.

Analog voltage resolution setting Set this item according to the system to be used.

Feed back pulse addition/subtraction setting Set this item according to the system to be used.

Deviation counter clear setting Set this item according to the system to be used.

Zero/gain adjustment mode/Normal mode setting Set "Normal mode".

Page 118 of the Mitsubishi Electronics QD73A1 user manual — Program example Reference
Page 118 · click to enlarge
Page 118

(3) Writing parameters

Write the set parameters to the CPU module, then reset the CPU module or turn off and on the power supply of

the programmable controller.

[Online] [Write to PLC...]

or Power off on

(4) I/O signals of the QD73A1

Refer to Page 30, Section 3.4.1. I/O signals used in program examples are assigned as in the list on Page 30,

Section 3.4.1.

(5) Program example

Refer to the following.

Program example Reference

Parameter setting program Page 117, Section 7.3.1

Near-point dog method OPR program Page 119, Section 7.3.2 (1)

Count method OPR program Page 122, Section 7.3.2 (2)

Positioning control program Page 125, Section 7.3.3 (1)

Two-phase trapezoidal positioning control program Page 127, Section 7.3.3 (2)

Speed-position control switch mode program Page 129, Section 7.3.3 (3)

Speed control operation program Page 131, Section 7.3.3 (4)

Fixed-feed operation program Page 133, Section 7.3.4

JOG operation program Page 135, Section 7.3.5

Current value change program Page 137, Section 7.3.6 (1)

Speed change program Page 138, Section 7.3.6 (2)

Deviation counter clearing program Page 140, Section 7.3.6 (3)

Stop program during positioning Page 141, Section 7.3.7

Page 119 of the Mitsubishi Electronics QD73A1 user manual — (1) Program detail
Page 119 · click to enlarge
Page 119

CHAPTER 7 PROGRAMMING

7.3.1 Parameter setting program

This program sets fixed parameters and variable parameters.

Mitsubishi Electronics QD73A1 — CHAPTER 7 PROGRAMMING diagram (page 119)
Fig. 47

Parameters described in this section can be set through GX Works2 also. ( Page 108, Section 6.3) The sequence program in this section is unnecessary when the parameters were set through GX Works2.

(1) Program detail

  • The following fixed parameters are set once the CPU module is in the RUN status.
Mitsubishi Electronics QD73A1 — (1) Program detail diagram (page 119)
Fig. 48 · (1) Program detail
  • As X30 is turned on, the following variable parameters are set.
Mitsubishi Electronics QD73A1 — (1) Program detail diagram (page 119)
Fig. 49 · (1) Program detail

7.3 When Using the Module in a Standard System Configuration 7.3.1 Parameter setting program

D4 Numerator of command pulse multiplication for electronic gear

D5 Denominator of command pulse multiplication for electronic gear

Page 120 of the Mitsubishi Electronics QD73A1 user manual — (4) Program example
Page 120 · click to enlarge
Page 120
Mitsubishi Electronics QD73A1 — 7.3.1 Parameter setting program diagram (page 120)
Fig. 50 · 7.3.1 Parameter setting program

SM402 Turns on for one scan once the CPU module is in the RUN status

(4) Program example

Mitsubishi Electronics QD73A1 — (4) Program example diagram (page 120)
Fig. 51 · (4) Program example

Numerator of command pulse multiplication for electronic gear (1)

Denominator of command pulse multiplication for electronic gear (1)

Page 121 of the Mitsubishi Electronics QD73A1 user manual — (b) Switch setting
Page 121 · click to enlarge
Page 121

CHAPTER 7 PROGRAMMING

7.3.2 OPR program

Programs in this section execute OPR in the near-point dog method or the count method.

(1) Near-point dog method OPR program

This program executes OPR in the near-point dog method. Suppose that fixed parameters and variable

parameters are already set. ( Page 117, Section 7.3.1)

(a) Program detail

  • The following OPR parameters are written once the CPU module is in the RUN status, and PLC READY

signal (Y2D) turns on.

Item Setting detail

Pr.10

Pr.11

Pr.12

  • As X31 is turned on after PLC READY signal (Y2D) turned on, the module executes OPR.

(b) Switch setting

Before executing the program, set "Near-point dog method" to "OPR method setting".

Project window [Intelligent Function Module] [QD73A1] [Switch Setting]

Mitsubishi Electronics QD73A1 — (b) Switch setting diagram (page 121)
Fig. 52 · (b) Switch setting

7.3 When Using the Module in a Standard System Configuration 7.3.2 OPR program

OP address 100pulse · OPR speed 5000pulse/s · Creep speed 500pulse/s

Page 122 of the Mitsubishi Electronics QD73A1 user manual — Device Description
Page 122 · click to enlarge
Page 122

(c) Execution condition

Check item Condition

Servo READY signal (READY) ON

Stop signal (STOP) OFF

Upper limit signal (FLS) ON

Lower limit signal (RLS) ON

Near-point dog signal (DOG) OFF

WDT error, H/W error signal (X10) OFF

QD73A1 READY signal (X11) OFF

OPR complete signal (X13) OFF

BUSY signal (X14) OFF

Excessive error signal (X17) OFF

Error detection signal (X18) OFF

OPR start complete signal (X20) OFF

Synchronization flag (X24) ON

OPR start signal (Y20) OFF

Stop signal (Y27) OFF

PLC READY signal (Y2D) OFF

Buffer memory OPR parameters No error

(d) Device used by the user

Device Description

D20 OP address (lower 16 bits)

D21 OP address (upper 16 bits)

D22 OPR speed (lower 16 bits)

D23 OPR speed (upper 16 bits)

D24 Creep speed (lower 16 bits)

D25 Creep speed (upper 16 bits)

M0 Fixed parameter setting memory

M34 OPR parameter setting memory

M37 OPR command pulse

SM402 Turns on for one scan once the CPU module is in the RUN status

Show 4 more labels / short text on this page
External I/O signal · I/O signal · X31 OPR command · M35 OPR request
Page 123 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 7 PROGRAMMING
Page 123 · click to enlarge
Page 123

CHAPTER 7 PROGRAMMING

(e) Program example

Mitsubishi Electronics QD73A1 — CHAPTER 7 PROGRAMMING diagram (page 123)
Fig. 53

*1 OPR parameters can be set through GX Works2 also. ( Page 108, Section 6.3) The sequence program that sets OPR parameters is unnecessary when the parameters were set through GX Works2.

7.3 When Using the Module in a Standard System Configuration 7.3.2 OPR program

Page 124 of the Mitsubishi Electronics QD73A1 user manual — (b) Switch setting
Page 124 · click to enlarge
Page 124

(2) Count method OPR program

This program executes OPR in the count method. Suppose that fixed parameters and variable parameters are

already set. ( Page 117, Section 7.3.1)

(a) Program detail

  • The following OPR parameters are written once the CPU module is in the RUN status, and PLC READY

signal (Y2D) turns on.

Item Setting detail

Pr.10

Pr.11

Pr.12

Setting for the movement amount after near-point dog

Pr.13

ON

  • As X31 is turned on after PLC READY signal (Y2D) turned on, the module executes OPR.

(b) Switch setting

Before executing the program, set "Count method" to "OPR method setting".

Project window [Intelligent Function Module] [QD73A1] [Switch Setting]

Mitsubishi Electronics QD73A1 — (b) Switch setting diagram (page 124)
Fig. 54 · (b) Switch setting
Show 4 more labels / short text on this page
OP address 100pulse · OPR speed 5000pulse/s · Creep speed 500pulse/s · 2000pulse
Page 125 of the Mitsubishi Electronics QD73A1 user manual — Device Description
Page 125 · click to enlarge
Page 125

CHAPTER 7 PROGRAMMING

(c) Execution condition

Check item Condition

Servo READY signal (READY) ON

Stop signal (STOP) OFF

Upper limit signal (FLS) ON

Lower limit signal (RLS) ON

WDT error, H/W error signal (X10) OFF

QD73A1 READY signal (X11) OFF

BUSY signal (X14) OFF

Excessive error signal (X17) OFF

Error detection signal (X18) OFF

OPR start complete signal (X20) OFF

Synchronization flag (X24) ON

OPR start signal (Y20) OFF

Stop signal (Y27) OFF

PLC READY signal (Y2D) OFF

Buffer memory OPR parameters No error

(d) Device used by the user

Device Description

D20 OP address (lower 16 bits)

D21 OP address (upper 16 bits)

D22 OPR speed (lower 16 bits)

D23 OPR speed (upper 16 bits)

7.3 When Using the Module in a Standard System Configuration 7.3.2 OPR program

D24 Creep speed (lower 16 bits)

D25 Creep speed (upper 16 bits)

D26 Movement amount after near-point dog ON (lower 16 bits)

D27 Movement amount after near-point dog ON (upper 16 bits)

M0 Fixed parameter setting memory

M34 OPR parameter setting memory

M37 OPR command pulse

SM402 Turns on for one scan once the CPU module is in the RUN status

Show 4 more labels / short text on this page
External I/O signal · I/O signal · X31 OPR command · M35 OPR request
Page 126 of the Mitsubishi Electronics QD73A1 user manual — (e) Program example
Page 126 · click to enlarge
Page 126

(e) Program example

Mitsubishi Electronics QD73A1 — (e) Program example diagram (page 126)
Fig. 55 · (e) Program example

*1 OPR parameters can be set through GX Works2 also. ( Page 108, Section 6.3) The sequence program that sets OPR parameters is unnecessary when the parameters were set through GX Works2.

Page 127 of the Mitsubishi Electronics QD73A1 user manual — (X21) OFF
Page 127 · click to enlarge
Page 127

CHAPTER 7 PROGRAMMING

7.3.3 Major positioning control program

Programs in this section execute major positioning control.

(1) Positioning control program

This program executes positioning control in the absolute system. Suppose that the parameter setting and OPR

were completed. ( Page 117, Section 7.3.1, Page 119, Section 7.3.2)

(a) Program detail

  • As X33 is turned on, the following positioning data are written.

Item Setting detail

Da.1

Positioning pattern 0Positioning control

Positioning address P1 100000pulse

Da.2

Positioning speed V1 10000pulse/s

Da.3

  • As X34 is turned on, the module executes positioning control in the absolute system.

(b) Execution condition

Check item Condition Note

Servo READY signal (READY) ON

Stop signal (STOP) OFF

Upper limit signal (FLS) ON

Lower limit signal (RLS) ON

WDT error, H/W error signal (X10) OFF

7.3 When Using the Module in a Standard System Configuration 7.3.3 Major positioning control program

QD73A1 READY signal (X11) ON

BUSY signal (X14) OFF

Excessive error signal (X17) OFF

Error detection signal (X18) OFF

Absolute positioning start complete signal

(X21) OFF

Synchronization flag (X24) ON

Absolute positioning start signal (Y21) OFF

Stop signal (Y27) OFF

PLC READY signal (Y2D) ON

When the positioning speed is set

exceeding " Speed limit

Pr.5

Buffer memory Positioning data No error

value", the positioning is executed

at " Speed limit value".

Pr.5

External I/O · signal · I/O signal

Page 128 of the Mitsubishi Electronics QD73A1 user manual — (d) Program example
Page 128 · click to enlarge
Page 128

(c) Device used by the user

Mitsubishi Electronics QD73A1 — (c) Device used by the user diagram (page 128)
Fig. 56 · (c) Device used by the user

(d) Program example

Mitsubishi Electronics QD73A1 — (d) Program example diagram (page 128)
Fig. 57 · (d) Program example

*1 Positioning data can be set through GX Works2 also. ( Page 109, Section 6.4) The sequence program that sets positioning data is unnecessary when the data were set through GX Works2.

Page 129 of the Mitsubishi Electronics QD73A1 user manual — Device Description
Page 129 · click to enlarge
Page 129

CHAPTER 7 PROGRAMMING

(2) Two-phase trapezoidal positioning control program

This program executes two-phase trapezoidal positioning control in the absolute system. Suppose that the

parameter setting and OPR were completed. ( Page 117, Section 7.3.1, Page 119, Section 7.3.2)

(a) Program detail

  • As X35 is turned on, the following positioning data are written.

Item Setting detail

Positioning pattern 1Two-phase trapezoidal positioning control

Da.1

Positioning address P1 100000pulse

Da.2

Positioning speed V1 10000pulse/s

Da.3

Da.4

Positioning address P2 150000pulse

Da.5

Positioning speed V2 12000pulse/s

  • As X36 is turned on, the module executes two-phase trapezoidal positioning control in the absolute

system.

(b) Execution condition

The execution condition is the same as that of positioning control program. ( Page 125, Section 7.3.3 (1)

(c) Device used by the user

Device Description

X35 Positioning data write command

X36 Two-phase trapezoidal positioning control start command

7.3 When Using the Module in a Standard System Configuration 7.3.3 Major positioning control program

D31 Positioning address P1 (lower 16 bits)

D32 Positioning address P1 (upper 16 bits)

D33 Positioning speed V1 (lower 16 bits)

D34 Positioning speed V1 (upper 16 bits)

D35 Positioning address P2 (lower 16 bits)

D36 Positioning address P2 (upper 16 bits)

D37 Positioning speed V2 (lower 16 bits)

D38 Positioning speed V2 (upper 16 bits)

M43 Two-phase trapezoidal positioning control start command pulse

(b)) · D30 Positioning pattern

Page 130 of the Mitsubishi Electronics QD73A1 user manual — (d) Program example
Page 130 · click to enlarge
Page 130

(d) Program example

Mitsubishi Electronics QD73A1 — (d) Program example diagram (page 130)
Fig. 58 · (d) Program example

*1 Positioning data can be set through GX Works2 also. ( Page 109, Section 6.4) The sequence program that sets positioning data is unnecessary when the data were set through GX Works2.

Page 131 of the Mitsubishi Electronics QD73A1 user manual — (Y2C) OFF
Page 131 · click to enlarge
Page 131

CHAPTER 7 PROGRAMMING

(3) Speed-position control switch mode program

This program switches the positioning mode to the "speed-position control switch mode". Suppose that the

parameter setting and OPR were completed. ( Page 117, Section 7.3.1, Page 119, Section 7.3.2)

(a) Program detail

  • As X37 is turned on, the positioning mode is set to "speed-position control switch mode".
  • As X38 is turned on, the following positioning data are written.

Item Setting detail

Da.2

Positioning address P1 5000pulse

Positioning speed V1 1000pulse/s

Da.3

  • As X39 is turned on, the module starts speed control. The module switches the operation to position

control following an external control switch command.

  • As X3B is turned on, the module restarts operation in case that the operation was stopped following a stop

signal input.

(b) Execution condition

Check item Condition Note

Servo READY signal (READY) ON

Stop signal (STOP) OFF

Upper limit signal (FLS) ON

Lower limit signal (RLS) ON

QD73A1 READY signal (X11) ON

BUSY signal (X14) OFF

Excessive error signal (X17) OFF

7.3 When Using the Module in a Standard System Configuration 7.3.3 Major positioning control program

Error detection signal (X18) OFF

Forward start complete signal (X22) OFF

Synchronization flag (X24) ON

Forward start signal (Y22) OFF

Reverse start signal (Y23) OFF

Speed-position mode restart signal (Y26) OFF

Stop signal (Y27) OFF

Speed-position switching enable signal

(Y2C) OFF

PLC READY signal (Y2D) ON

When the positioning speed is set

exceeding " Speed limit

Pr.5

Buffer memory Positioning data No error

value", the positioning is executed

at " Speed limit value".

Pr.5

External I/O · signal · I/O signal

Page 132 of the Mitsubishi Electronics QD73A1 user manual — (d) Program example
Page 132 · click to enlarge
Page 132

(c) Device used by the user

Mitsubishi Electronics QD73A1 — (c) Device used by the user diagram (page 132)
Fig. 59 · (c) Device used by the user

(d) Program example

Mitsubishi Electronics QD73A1 — (d) Program example diagram (page 132)
Fig. 60 · (d) Program example

Command the start of the speed-position control switch mode.

Command the restart of the speed-position control switch mode.

*1 Variable parameters and positioning data can be set through GX Works2 also. ( Page 108, Section 6.3, Page 109, Section 6.4) The sequence program that sets variable parameters and positioning data is unnecessary when the data were set through GX Works2.

Page 133 of the Mitsubishi Electronics QD73A1 user manual — (Y2C) OFF
Page 133 · click to enlarge
Page 133

CHAPTER 7 PROGRAMMING

(4) Speed control operation program

This program executes speed control using the speed control function of the speed-position control switch mode.

Suppose that parameters are already set. ( Page 117, Section 7.3.1)

(a) Program detail

  • As X3C is turned on, the positioning mode is set to "speed-position control switch mode".
  • As X3D is turned on, the following positioning data is written.

Item Setting detail

Da.3

Positioning speed V1 1000pulse/s

  • As X3E is turned on, the module starts speed control of forward run. As X3F is turned on, the module

starts speed control of reverse run.

(b) Execution condition

Check item Condition Note

Servo READY signal (READY) ON

Stop signal (STOP) OFF

Upper limit signal (FLS) ON

Lower limit signal (RLS) ON

QD73A1 READY signal (X11) ON

BUSY signal (X14) OFF

Excessive error signal (X17) OFF

Error detection signal (X18) OFF

Forward start complete signal (X22) OFF

Reverse start complete signal (X23) OFF

7.3 When Using the Module in a Standard System Configuration 7.3.3 Major positioning control program

Synchronization flag (X24) ON

Forward start signal (Y22) OFF

Reverse start signal (Y23) OFF

Speed-position mode restart signal (Y26) OFF

Stop signal (Y27) OFF

Speed-position switching enable signal

(Y2C) OFF

PLC READY signal (Y2D) ON

When the positioning speed is set

exceeding " Speed limit

Pr.5

Buffer memory Positioning data No error

value", the positioning is executed

at " Speed limit value".

Pr.5

External I/O · signal · I/O signal

Page 134 of the Mitsubishi Electronics QD73A1 user manual — (d) Program example
Page 134 · click to enlarge
Page 134

(c) Device used by the user

Mitsubishi Electronics QD73A1 — (c) Device used by the user diagram (page 134)
Fig. 61 · (c) Device used by the user

(d) Program example

Mitsubishi Electronics QD73A1 — (d) Program example diagram (page 134)
Fig. 62 · (d) Program example

*1 Variable parameters and positioning data can be set through GX Works2 also. ( Page 108, Section 6.3, Page 109, Section 6.4) The sequence program that sets variable parameters and positioning data is unnecessary when the data were set through GX Works2.

Page 135 of the Mitsubishi Electronics QD73A1 user manual — (X21) OFF
Page 135 · click to enlarge
Page 135

CHAPTER 7 PROGRAMMING

7.3.4 Fixed-feed operation program

This program executes positioning in the address increasing direction according to the specified movement amount

and speed. Execute fixed-feed operation by turning on Fixed-feed start command repeatedly. Use the current value

change function and positioning start in the absolute system. Suppose that parameter setting and OPR were

completed. ( Page 117, Section 7.3.1, Page 119, Section 7.3.2)

(1) Program detail

  • As X40 is turned on, the following positioning data are written.

Item Setting detail

Positioning address P1 20000pulse

Da.2

Positioning speed V1 1000pulse/s

Da.3

  • As X41 is turned on, the module starts fixed-feed operation.

(2) Execution condition

Check item Condition Note

Servo READY signal (READY) ON

Stop signal (STOP) OFF

Upper limit signal (FLS) ON

Lower limit signal (RLS) ON

QD73A1 READY signal (X11) ON

BUSY signal (X14) OFF

Excessive error signal (X17) OFF

7.3 When Using the Module in a Standard System Configuration 7.3.4 Fixed-feed operation program

Error detection signal (X18) OFF

Absolute positioning start complete signal

(X21) OFF

Synchronization flag (X24) ON

Absolute positioning start signal (Y21) OFF

Stop signal (Y27) OFF

PLC READY signal (Y2D) ON

When the positioning speed is set

exceeding " Speed limit

Pr.5

Buffer memory Positioning data No error

value", the positioning is executed

at " Speed limit value".

Pr.5

External I/O · signal · I/O signal

Page 136 of the Mitsubishi Electronics QD73A1 user manual — (4) Program example
Page 136 · click to enlarge
Page 136

(3) Device used by the user

Mitsubishi Electronics QD73A1 — (3) Device used by the user diagram (page 136)
Fig. 63 · (3) Device used by the user

(4) Program example

Mitsubishi Electronics QD73A1 — (4) Program example diagram (page 136)
Fig. 64 · (4) Program example

*1 Positioning data can be set through GX Works2 also. ( Page 109, Section 6.4) The sequence program that sets positioning data is unnecessary when the data were set through GX Works2.

Page 137 of the Mitsubishi Electronics QD73A1 user manual — Device Description
Page 137 · click to enlarge
Page 137

CHAPTER 7 PROGRAMMING

7.3.5 JOG operation program

This program executes JOG operation while a JOG start command is on. Suppose that parameters are already set.

( Page 117, Section 7.3.1)

(1) Program detail

  • As X42 is turned on, JOG speed is written.

Item Setting detail

Cd.3

  • As X43 is turned on, the module executes forward JOG operation. As X44 is turned on, the module executes

reverse JOG operation.

(2) Execution condition

Check item Condition Note

Servo READY signal (READY) ON

Stop signal (STOP) OFF

Upper limit signal (FLS) ON

Lower limit signal (RLS) ON

QD73A1 READY signal (X11) ON

BUSY signal (X14) OFF

External stop signal (X1D) OFF

Synchronization flag (X24) ON

Forward JOG start signal (Y24) OFF

7.3 When Using the Module in a Standard System Configuration 7.3.5 JOG operation program

Reverse JOG start signal (Y25) OFF

Stop signal (Y27) OFF

PLC READY signal (Y2D) ON

When " JOG speed" is set

Cd.3

exceeding " Speed limit

Buffer memory JOG speed No error

Pr.5

Cd.3

value", the operation is executed at

" Speed limit value".

Pr.5

(3) Device used by the user

Device Description

X42 JOG speed write command

X43 Forward JOG command

X44 Reverse JOG command

D72 JOG speed (lower 16 bits)

D73 JOG speed (upper 16 bits)

Show 5 more labels / short text on this page
JOG speed 10000pulse/s · External I/O · signal · I/O signal · M55 JOG command
Page 138 of the Mitsubishi Electronics QD73A1 user manual — (4) Program example
Page 138 · click to enlarge
Page 138

(4) Program example

Mitsubishi Electronics QD73A1 — (4) Program example diagram (page 138)
Fig. 65 · (4) Program example
Page 139 of the Mitsubishi Electronics QD73A1 user manual — (b) Execution condition
Page 139 · click to enlarge
Page 139

CHAPTER 7 PROGRAMMING

7.3.6 Control change program

(1) Current value change program

This program changes the current value to "0".

(a) Program detail

As X45 is turned on, the current value is changed.

Item Setting detail

New current value 0pulse

Cd.1

(b) Execution condition

Mitsubishi Electronics QD73A1 — (b) Execution condition diagram (page 139)
Fig. 66 · (b) Execution condition

7.3 When Using the Module in a Standard System Configuration 7.3.6 Control change program

Page 140 of the Mitsubishi Electronics QD73A1 user manual — Device Description
Page 140 · click to enlarge
Page 140

(2) Speed change program

This program changes positioning speed.

(a) Program detail

As X46 is turned on, positioning speed is changed.

Item Setting detail

Cd.2

New speed value 50000pulse/s

(b) Execution condition

Check item Condition Note

Servo READY signal (READY) ON

Stop signal (STOP) OFF

Upper limit signal (FLS) ON

Lower limit signal (RLS) ON

WDT error, H/W error signal (X10) OFF

QD73A1 READY signal (X11) ON

BUSY signal (X14) ON

Excessive error signal (X17) OFF

Error detection signal (X18) OFF

Synchronization flag (X24) ON

Stop signal (Y27) OFF

PLC READY signal (Y2D) ON

When " New speed value" is

Cd.2

set exceeding " Speed limit

Pr.5

Buffer memory New speed value No error

Cd.2

value", the operation is executed at

" Speed limit value".

Pr.5

(c) Device used by the user

Device Description

X46 Speed change command

D102 New speed value (lower 16 bits)

D103 New speed value (upper 16 bits)

D91 Speed change request

Show 4 more labels / short text on this page
External I/O · signal · I/O signal · M65 Speed change
Page 141 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 7 PROGRAMMING
Page 141 · click to enlarge
Page 141

CHAPTER 7 PROGRAMMING

(d) Program example

Mitsubishi Electronics QD73A1 — CHAPTER 7 PROGRAMMING diagram (page 141)
Fig. 67
Mitsubishi Electronics QD73A1 — CHAPTER 7 PROGRAMMING diagram (page 141)
Fig. 68

7.3 When Using the Module in a Standard System Configuration 7.3.6 Control change program

Page 142 of the Mitsubishi Electronics QD73A1 user manual — (d) Program example
Page 142 · click to enlarge
Page 142

(3) Deviation counter clearing program

This program clears the deviation counter to 0.

(a) Program detail

As X47 is turned on, the deviation counter is cleared to 0.

Item Setting detail

Cd.4

Deviation counter clear command 1Clear the deviation counter

(b) Execution condition

Mitsubishi Electronics QD73A1 — (b) Execution condition diagram (page 142)
Fig. 69 · (b) Execution condition

(c) Device used by the user

Mitsubishi Electronics QD73A1 — (c) Device used by the user diagram (page 142)
Fig. 70 · (c) Device used by the user

(d) Program example

Mitsubishi Electronics QD73A1 — (d) Program example diagram (page 142)
Fig. 71 · (d) Program example
Page 143 of the Mitsubishi Electronics QD73A1 user manual — Device Description
Page 143 · click to enlarge
Page 143

CHAPTER 7 PROGRAMMING

7.3.7 Stop program during positioning

This program stops the positioning in execution.

(a) Program detail

As X3A is turned on, the module stops the positioning in execution.

(b) Device used by the user

Device Description

(c) Program example

Turn on Stop signal.

Turn off Stop signal.

7.3 When Using the Module in a Standard System Configuration 7.3.7 Stop program during positioning

X3A Stop command

Page 144 of the Mitsubishi Electronics QD73A1 user manual — (1) System configuration
Page 144 · click to enlarge
Page 144

7.4 When Using the Module in a Remote I/O Network

This section introduces program examples of when the QD73A1 is used in a MELSECNET/H remote I/O network.

For details on a MELSECNET/H remote I/O network, refer to the following.

Q Corresponding MELSECNET/H Network System Reference Manual (Remote I/O network)

(1) System configuration

Mitsubishi Electronics QD73A1 — (1) System configuration diagram (page 144)
Fig. 72 · (1) System configuration
First half(Empty 0 point) Second half: X/Y1020 to X/Y103F (Intelli. 32points)
Page 145 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 7 PROGRAMMING
Page 145 · click to enlarge
Page 145

CHAPTER 7 PROGRAMMING

(2) Setting on the master station

1. Create a project on GX Works2.

Select "QCPU (Q mode)" for "PLC Series", and select the CPU module used for "PLC Type".

[Project] [New...]

Mitsubishi Electronics QD73A1 — CHAPTER 7 PROGRAMMING diagram (page 145)
Fig. 73
2. Display the network parameter setting window, and configure the setting as follows.

Project window [Parameter] [Network Parameter]

Mitsubishi Electronics QD73A1 — CHAPTER 7 PROGRAMMING diagram (page 145)
Fig. 74

7.4 When Using the Module in a Remote I/O Network

[Ethernet/CC IE/MELSECNET]

Page 146 of the Mitsubishi Electronics QD73A1 user manual — 7.4 When Using the Module in a Remote I/O Network
Page 146 · click to enlarge
Page 146
3. Display the network range assignment setting window, and configure the setting as follows.

Project window [Parameter] [Network Parameter]

Mitsubishi Electronics QD73A1 — 7.4 When Using the Module in a Remote I/O Network diagram (page 146)
Fig. 75 · 7.4 When Using the Module in a Remote I/O Network

Project window [Parameter] [Network Parameter]

[Ethernet/CC IE/MELSECNET] button "Switch Screens"

Mitsubishi Electronics QD73A1 — 7.4 When Using the Module in a Remote I/O Network diagram (page 146)
Fig. 76 · 7.4 When Using the Module in a Remote I/O Network
4. Display the refresh parameter setting window, and configure the setting as follows.

Project window [Parameter] [Network Parameter]

Mitsubishi Electronics QD73A1 — 7.4 When Using the Module in a Remote I/O Network diagram (page 146)
Fig. 77 · 7.4 When Using the Module in a Remote I/O Network
5. Write the set parameters to the CPU module on the master station. Then reset the CPU module or

turn off and on the power supply of the programmable controller.

[Online] [Write to PLC...]

or Power off on

[Ethernet/CC IE/MELSECNET] button · "XY Setting" · [Ethernet/CC IE/MELSECNET] button

Page 147 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 7 PROGRAMMING
Page 147 · click to enlarge
Page 147

CHAPTER 7 PROGRAMMING

(3) Setting on the remote I/O station

1. Create a project on GX Works2.

Select "QCPU (Q mode)" for "PLC Series", and select "QJ72LP25/QJ72BR15(RemoteI/O)" for "PLC Type".

[Project] [New...]

Mitsubishi Electronics QD73A1 — CHAPTER 7 PROGRAMMING diagram (page 147)
Fig. 78
2. Add the QD73A1 to the project on GX Works2.

Project window [Intelligent Function Module] Right-click [New Module...]

Mitsubishi Electronics QD73A1 — CHAPTER 7 PROGRAMMING diagram (page 147)
Fig. 79

7.4 When Using the Module in a Remote I/O Network

Page 148 of the Mitsubishi Electronics QD73A1 user manual — MODE
Page 148 · click to enlarge
Page 148
3. Display the QD73A1's switch setting window, and configure the setting as follows.

Project window [Intelligent Function Module] [QD73A1] [Switch Setting]

Mitsubishi Electronics QD73A1 — 7.4 When Using the Module in a Remote I/O Network diagram (page 148)
Fig. 80 · 7.4 When Using the Module in a Remote I/O Network

Item Setting value

Rotation direction setting Set this item according to the system to be used.

Accumulated pulse setting Set this item according to the system to be used.

Multiplication setting Set this item according to the system to be used.

OPR direction setting Set this item according to the system to be used.

OPR method setting Set the near-point dog method or the count method.

Encoder I/F setting Set this item according to the system to be used.

Analog voltage resolution setting Set this item according to the system to be used.

Feed back pulse addition/subtraction setting Set this item according to the system to be used.

Deviation counter clear setting Set this item according to the system to be used.

Zero/gain adjustment mode/Normal mode setting Set "Normal mode".

4. Write the set parameters to the remote I/O module, then reset the remote I/O module.

[Online] [Write to PLC...]

RESET Press the switch in this direction for a while.

MODE

Page 149 of the Mitsubishi Electronics QD73A1 user manual — Y102E Y103E
Page 149 · click to enlarge
Page 149

CHAPTER 7 PROGRAMMING

(4) I/O signals of the QD73A1

The following is the I/O signal assignment viewed from the master station side.

(a) Input signal list

Input signal (CPU module QD73A1) Input signal (CPU module QD73A1)

Device No. Signal name Device No. Signal name

X1020 WDT error, H/W error signal X1030 OPR start complete signal

X1021 QD73A1 READY signal X1031 Absolute positioning start complete signal

X1022 OPR request signal X1032 Forward start complete signal

X1023 OPR complete signal X1033 Reverse start complete signal

X1024 BUSY signal X1034 Synchronization flag

X1025 Positioning complete signal X1035

X1026 In-position signal X1036

X1027 Excessive error signal X1037

X1028 Error detection signal X1038

X1029 Overflow signal X1039

X102A Underflow signal X103A Zero/gain adjustment data writing complete

X102B Servo READY signal X103B Zero/gain adjustment change complete flag

X102C Near-point dog signal X103C Set value change complete flag

X102D External stop signal X103D Operating status of the speed-position

X102E Upper limit signal X103E

Use prohibited X102F Lower limit signal X103F

(5) Output signal list

7.4 When Using the Module in a Remote I/O Network

Output signal (CPU module QD73A1) Output signal (CPU module QD73A1)

Device No. Signal name Device No. Signal name

Y1020

Y1030 OPR start signal

Y1021 Y1031 Absolute positioning start signal

Y1022 Y1032 Forward start signal

Y1023 Y1033 Reverse start signal

Y1024 Y1034 Forward JOG start signal

Y1025 Y1035 Reverse JOG start signal

Y1026 Y1036 Speed-position mode restart signal

Y1027 Y1037 Stop signal

Y1028 Y1038 Error reset signal

Y1029 Y1039 Overflow reset signal

Y102A Zero/gain adjustment data writing request

signal Y103A Underflow reset signal

Y102B Zero/gain adjustment change request

signal Y103B Use prohibited

Y102C Set value change request signal Y103C Speed-position switching enable signal

Y102D

Y103D PLC READY signal

Y102E Y103E

Use prohibited Y102F Y103F

If a "Use prohibited" area is turned on/off through a sequence program, the QD73A1's function cannot be guaranteed.

Show 5 more labels / short text on this page
Use prohibited · flag · control switch mode · Use prohibited · Use prohibited
Page 150 of the Mitsubishi Electronics QD73A1 user manual — (7) Program example
Page 150 · click to enlarge
Page 150

(6) Interlock program of MELSECNET/H remote I/O network

For programs introduced in Page 149, Section 7.4.1 to Page 177, Section 7.4.7, make interlocks using data link

status of the own station and the other station as shown below.

Mitsubishi Electronics QD73A1 — (6) Interlock program of MELSECNET/H remote I/O network diagram (page 150)
Fig. 81 · (6) Interlock program of MELSECNET/H remote I/O netw…

Programs described in Page 149, Section 7.4.1, Page 177, Section 7.4.7

(7) Program example

Refer to the following.

Mitsubishi Electronics QD73A1 — (7) Program example diagram (page 150)
Fig. 82 · (7) Program example

Near-point dog method OPR program Page 151, Section 7.4.2 (1)

Count method OPR program Page 154, Section 7.4.2 (2)

Two-phase trapezoidal positioning control program Page 159, Section 7.4.3 (2)

Speed-position control switch mode program Page 161, Section 7.4.3 (3)

Speed control operation program Page 164, Section 7.4.3 (4)

Current value change program Page 172, Section 7.4.6 (1)

Deviation counter clearing program Page 176, Section 7.4.6 (3)

Page 151 of the Mitsubishi Electronics QD73A1 user manual — (1) Program detail
Page 151 · click to enlarge
Page 151

CHAPTER 7 PROGRAMMING

7.4.1 Parameter setting program

This program sets fixed parameters and variable parameters.

Mitsubishi Electronics QD73A1 — CHAPTER 7 PROGRAMMING diagram (page 151)
Fig. 83

Parameters described in this section can be set through GX Works2 also. ( Page 108, Section 6.3) The sequence program in this section is unnecessary when the parameters were set through GX Works2.

(1) Program detail

  • As X20 is turned on, the following fixed parameters are set.
Mitsubishi Electronics QD73A1 — (1) Program detail diagram (page 151)
Fig. 84 · (1) Program detail
  • As X21 is turned on, the following variable parameters are set.
Mitsubishi Electronics QD73A1 — (1) Program detail diagram (page 151)
Fig. 85 · (1) Program detail

7.4 When Using the Module in a Remote I/O Network 7.4.1 Parameter setting program

D4 Numerator of command pulse multiplication for electronic gear

D5 Denominator of command pulse multiplication for electronic gear

Page 152 of the Mitsubishi Electronics QD73A1 user manual — (4) Program example
Page 152 · click to enlarge
Page 152
Mitsubishi Electronics QD73A1 — 7.4.1 Parameter setting program diagram (page 152)
Fig. 86 · 7.4.1 Parameter setting program

(4) Program example

Mitsubishi Electronics QD73A1 — (4) Program example diagram (page 152)
Fig. 87 · (4) Program example

Numerator of command pulse multiplication for electronic gear (1)

Denominator of command pulse multiplication for electronic gear (1)

Page 153 of the Mitsubishi Electronics QD73A1 user manual — (b) Switch setting
Page 153 · click to enlarge
Page 153

CHAPTER 7 PROGRAMMING

7.4.2 OPR program

Programs in this section execute OPR in the near-point dog method or the count method.

(1) Near-point dog method OPR program

This program executes OPR in the near-point dog method. Suppose that fixed parameters and variable

parameters are already set. ( Page 149, Section 7.4.1)

(a) Program detail

  • As X22 is turned on, the following OPR parameters are written and PLC READY signal (Y103D) turns on.

Item Setting detail

Pr.10

Pr.11

Pr.12

  • As X23 is turned on after PLC READY signal (Y103D) turned on, the module executes OPR.

(b) Switch setting

Before executing the program, set "Near-point dog method" to "OPR method setting".

Project window [Intelligent Function Module] [QD73A1] [Switch Setting]

7.4 When Using the Module in a Remote I/O Network 7.4.2 OPR program

OP address 100pulse · OPR speed 5000pulse/s · Creep speed 500pulse/s

Page 154 of the Mitsubishi Electronics QD73A1 user manual — Device Description
Page 154 · click to enlarge
Page 154

(c) Execution condition

Check item Condition

Servo READY signal (READY) ON

Stop signal (STOP) OFF

Upper limit signal (FLS) ON

Lower limit signal (RLS) ON

Near-point dog signal (DOG) OFF

WDT error, H/W error signal (X1020) OFF

QD73A1 READY signal (X1021) OFF

OPR complete signal (X1023) OFF

BUSY signal (X1024) OFF

Excessive error signal (X1027) OFF

Error detection signal (X1028) OFF

OPR start complete signal (X1030) OFF

Synchronization flag (X1034) ON

OPR start signal (Y1030) OFF

Stop signal (Y1037) OFF

PLC READY signal (Y103D) OFF

Buffer memory OPR parameters No error

(d) Device used by the user

Device Description

X22 OPR parameter setting command

D20 OP address (lower 16 bits)

D21 OP address (upper 16 bits)

D22 OPR speed (lower 16 bits)

D23 OPR speed (upper 16 bits)

D24 Creep speed (lower 16 bits)

D25 Creep speed (upper 16 bits)

M3 OPR parameter writing

M6 OPR parameter setting memory

M7 OPR command pulse

M210 Z(P).REMTO instruction completion

M211 Z(P).REMTO instruction failure

External I/O signal · I/O signal · X23 OPR command

Page 155 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 7 PROGRAMMING
Page 155 · click to enlarge
Page 155

CHAPTER 7 PROGRAMMING

(e) Program example

Mitsubishi Electronics QD73A1 — CHAPTER 7 PROGRAMMING diagram (page 155)
Fig. 88

*1 OPR parameters can be set through GX Works2 also. ( Page 108, Section 6.3) The sequence program that sets OPR parameters is unnecessary when the parameters were set through GX Works2.

7.4 When Using the Module in a Remote I/O Network 7.4.2 OPR program

Page 156 of the Mitsubishi Electronics QD73A1 user manual — (b) Switch setting
Page 156 · click to enlarge
Page 156

(2) Count method OPR program

This program executes OPR in the count method. Suppose that fixed parameters and variable parameters are

already set. ( Page 149, Section 7.4.1)

(a) Program detail

  • As X22 is turned on, the following OPR parameters are written and PLC READY signal (Y103D) turns on.

Item Setting detail

Pr.10

Pr.11

Pr.12

Pr.13

Setting for the movement amount after near-point

  • As X24 is turned on after PLC READY signal (Y103D) turned on, the module executes OPR.

(b) Switch setting

Before executing the program, set "Count method" to "OPR method setting".

Project window [Intelligent Function Module] [QD73A1] [Switch Setting]

Show 5 more labels / short text on this page
OP address 100pulse · OPR speed 5000pulse/s · Creep speed 500pulse/s · 2000pulse · dog ON
Page 157 of the Mitsubishi Electronics QD73A1 user manual — Device Description
Page 157 · click to enlarge
Page 157

CHAPTER 7 PROGRAMMING

(c) Execution condition

Check item Condition

Servo READY signal (READY) ON

Stop signal (STOP) OFF

Upper limit signal (FLS) ON

Lower limit signal (RLS) ON

WDT error, H/W error signal (X1020) OFF

QD73A1 READY signal (X1021) OFF

BUSY signal (X1024) OFF

Excessive error signal (X1027) OFF

Error detection signal (X1028) OFF

OPR start complete signal (X1030) OFF

Synchronization flag (X1034) ON

OPR start signal (Y1030) OFF

Stop signal (Y1037) OFF

PLC READY signal (Y103D) OFF

Buffer memory OPR parameters No error

(d) Device used by the user

Device Description

X22 OPR parameter setting command

D20 OP address (lower 16 bits)

D21 OP address (upper 16 bits)

7.4 When Using the Module in a Remote I/O Network 7.4.2 OPR program

D22 OPR speed (lower 16 bits)

D23 OPR speed (upper 16 bits)

D24 Creep speed (lower 16 bits)

D25 Creep speed (upper 16 bits)

D26 Movement amount after near-point dog ON (lower 16 bits)

D27 Movement amount after near-point dog ON (upper 16 bits)

M3 OPR parameter writing

M6 OPR parameter setting memory

M7 OPR command pulse

M210 Z(P).REMTO instruction completion

M211 Z(P).REMTO instruction failure

External I/O signal · I/O signal · X24 OPR command

Page 158 of the Mitsubishi Electronics QD73A1 user manual — (e) Program example
Page 158 · click to enlarge
Page 158

(e) Program example

Mitsubishi Electronics QD73A1 — (e) Program example diagram (page 158)
Fig. 89 · (e) Program example

*1 OPR parameters can be set through GX Works2 also. ( Page 108, Section 6.3) The sequence program that sets OPR parameters is unnecessary when the parameters were set through GX Works2.

Page 159 of the Mitsubishi Electronics QD73A1 user manual — (X1031) OFF
Page 159 · click to enlarge
Page 159

CHAPTER 7 PROGRAMMING

7.4.3 Major positioning control program

Programs in this section execute major positioning control.

(1) Positioning control program

This program executes positioning control in the absolute system. Suppose that the parameter setting and OPR

were completed. ( Page 149, Section 7.4.1, Page 151, Section 7.4.2)

(a) Program detail

  • As X25 is turned on, the following positioning data are written.

Item Setting detail

Da.1

Positioning pattern 0Positioning control

Positioning address P1 100000pulse

Da.2

Positioning speed V1 10000pulse/s

Da.3

  • As X26 is turned on, the module executes positioning control in the absolute system.

(b) Execution condition

Check item Condition Note

Servo READY signal (READY) ON

Stop signal (STOP) OFF

Upper limit signal (FLS) ON

Lower limit signal (RLS) ON

WDT error, H/W error signal (X1020) OFF

7.4 When Using the Module in a Remote I/O Network 7.4.3 Major positioning control program

QD73A1 READY signal (X1021) ON

BUSY signal (X1024) OFF

Excessive error signal (X1027) OFF

Error detection signal (X1028) OFF

Absolute positioning start complete signal

(X1031) OFF

Synchronization flag (X1034) ON

Absolute positioning start signal (Y1031) OFF

Stop signal (Y1037) OFF

PLC READY signal (Y103D) ON

When the positioning speed is set

exceeding " Speed limit

Pr.5

Buffer memory Positioning data No error

value", the positioning is executed

at " Speed limit value".

Pr.5

External I/O · signal · I/O signal

Page 160 of the Mitsubishi Electronics QD73A1 user manual — (d) Program example
Page 160 · click to enlarge
Page 160

(c) Device used by the user

Mitsubishi Electronics QD73A1 — (c) Device used by the user diagram (page 160)
Fig. 90 · (c) Device used by the user

(d) Program example

Mitsubishi Electronics QD73A1 — (d) Program example diagram (page 160)
Fig. 91 · (d) Program example

*1 Positioning data can be set through GX Works2 also. ( Page 109, Section 6.4) The sequence program that sets positioning data is unnecessary when the data were set through GX Works2.

Page 161 of the Mitsubishi Electronics QD73A1 user manual — Device Description
Page 161 · click to enlarge
Page 161

CHAPTER 7 PROGRAMMING

(2) Two-phase trapezoidal positioning control program

This program executes two-phase trapezoidal positioning control in the absolute system. Suppose that the

parameter setting and OPR were completed. ( Page 149, Section 7.4.1, Page 151, Section 7.4.2)

(a) Program detail

  • As X27 is turned on, the following positioning data are written.

Item Setting detail

Positioning pattern 1Two-phase trapezoidal positioning control

Da.1

Positioning address P1 100000pulse

Da.2

Positioning speed V1 10000pulse/s

Da.3

Da.4

Positioning address P2 150000pulse

Da.5

Positioning speed V2 12000pulse/s

  • As X28 is turned on, the module executes two-phase trapezoidal positioning control in the absolute

system.

(b) Execution condition

The execution condition is the same as that of positioning control program. ( Page 157, Section 7.4.3 (1)

(c) Device used by the user

Device Description

X27 Positioning data write command

X28 Two-phase trapezoidal positioning control start command

7.4 When Using the Module in a Remote I/O Network 7.4.3 Major positioning control program

D32 Positioning address P1 (lower 16 bits)

D33 Positioning address P1 (upper 16 bits)

D34 Positioning speed V1 (lower 16 bits)

D35 Positioning speed V1 (upper 16 bits)

D36 Positioning address P2 (lower 16 bits)

D37 Positioning address P2 (upper 16 bits)

D38 Positioning speed V2 (lower 16 bits)

D39 Positioning speed V2 (upper 16 bits)

M15 Positioning data writing

M45 Two-phase trapezoidal positioning control start command pulse

M230 Z(P).REMTO instruction completion

M231 Z(P).REMTO instruction failure

(b)) · D31 Positioning pattern

Page 162 of the Mitsubishi Electronics QD73A1 user manual — (d) Program example
Page 162 · click to enlarge
Page 162

(d) Program example

Mitsubishi Electronics QD73A1 — (d) Program example diagram (page 162)
Fig. 92 · (d) Program example

*1 Positioning data can be set through GX Works2 also. ( Page 109, Section 6.4) The sequence program that sets positioning data is unnecessary when the data were set through GX Works2.

Page 163 of the Mitsubishi Electronics QD73A1 user manual — (Y103C) OFF
Page 163 · click to enlarge
Page 163

CHAPTER 7 PROGRAMMING

(3) Speed-position control switch mode program

This program switches the positioning mode to the "speed-position control switch mode". Suppose that the

parameter setting and OPR were completed. ( Page 149, Section 7.4.1, Page 151, Section 7.4.2)

(a) Program detail

  • As X29 is turned on, the positioning mode is set to "speed-position control switch mode".
  • As X2A is turned on, the following positioning data are written.

Item Setting detail

Da.2

Positioning address P1 5000pulse

Positioning speed V1 1000pulse/s

Da.3

  • As X2B is turned on, the module starts speed control. The module switches the operation to position

control following an external control switch command.

  • As X2D is turned on, the module restarts operation in case that the operation was stopped following a stop

signal input.

(b) Execution condition

Check item Condition Note

Servo READY signal (READY) ON

Stop signal (STOP) OFF

Upper limit signal (FLS) ON

Lower limit signal (RLS) ON

QD73A1 READY signal (X1021) ON

BUSY signal (X1024) OFF

Excessive error signal (X1027) OFF

7.4 When Using the Module in a Remote I/O Network 7.4.3 Major positioning control program

Error detection signal (X1028) OFF

Forward start complete signal (X1032) OFF

Synchronization flag (X1034) ON

Forward start signal (Y1032) OFF

Reverse start signal (Y1033) OFF

Speed-position mode restart signal

(Y1036) OFF

Stop signal (Y1037) OFF

Speed-position switching enable signal

(Y103C) OFF

PLC READY signal (Y103D) ON

When the positioning speed is set

exceeding " Speed limit

Pr.5

Buffer memory Positioning data No error

value", the positioning is executed

at " Speed limit value".

Pr.5

External I/O · signal · I/O signal

Page 164 of the Mitsubishi Electronics QD73A1 user manual — Device Description
Page 164 · click to enlarge
Page 164

(c) Device used by the user

Device Description

X29 Variable parameter change command

X2A Positioning data write command

X2B Speed-position control positioning start command

X2D Speed-position control positioning restart command

D42 Positioning address P1 (lower 16 bits)

D43 Positioning address P1 (upper 16 bits)

D44 Positioning speed V1 (lower 16 bits)

D45 Positioning speed V1 (upper 16 bits)

M20 Variable parameter change

M21 Positioning data writing

M50 Speed-position control positioning start command pulse

M52 Speed-position control positioning restart command pulse

M240 Z(P).REMTO instruction completion

M241 Z(P).REMTO instruction failure

M242 Z(P).REMTO instruction completion

M243 Z(P).REMTO instruction failure

D40 Positioning mode

Page 165 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 7 PROGRAMMING
Page 165 · click to enlarge
Page 165

CHAPTER 7 PROGRAMMING

(d) Program example

Mitsubishi Electronics QD73A1 — CHAPTER 7 PROGRAMMING diagram (page 165)
Fig. 93

Command the start of the speed-position control switch mode.

Command the restart of the speed-position control switch mode.

7.4 When Using the Module in a Remote I/O Network 7.4.3 Major positioning control program

*1 Variable parameters and positioning data can be set through GX Works2 also. ( Page 108, Section 6.3, Page 109, Section 6.4) The sequence program that sets variable parameters and positioning data is unnecessary when the data were set through GX Works2.

Page 166 of the Mitsubishi Electronics QD73A1 user manual — (Y103C) OFF
Page 166 · click to enlarge
Page 166

(4) Speed control operation program

This program executes speed control using the speed control function of the speed-position control switch mode.

Suppose that parameters are already set. ( Page 149, Section 7.4.1)

(a) Program detail

  • As X2E is turned on, the positioning mode is set to "speed-position control switch mode".
  • As X2F is turned on, the following positioning data is written.

Item Setting detail

Da.3

Positioning speed V1 1000pulse/s

  • As X30 is turned on, the module starts speed control of forward run. As X31 is turned on, the module starts

speed control of reverse run.

(b) Execution condition

Check item Condition Note

Servo READY signal (READY) ON

Stop signal (STOP) OFF

Upper limit signal (FLS) ON

Lower limit signal (RLS) ON

QD73A1 READY signal (X1021) ON

BUSY signal (X1024) OFF

Excessive error signal (X1027) OFF

Error detection signal (X1028) OFF

Forward start complete signal (X1032) OFF

Reverse start complete signal (X1033) OFF

Synchronization flag (X1034) ON

Forward start signal (Y1032) OFF

Reverse start signal (Y1033) OFF

Speed-position mode restart signal

(Y1036) OFF

Stop signal (Y1037) OFF

Speed-position switching enable signal

(Y103C) OFF

PLC READY signal (Y103D) ON

When the positioning speed is set

exceeding " Speed limit

Pr.5

Buffer memory Positioning data No error

value", the positioning is executed

at " Speed limit value".

Pr.5

External I/O · signal · I/O signal

Page 167 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 7 PROGRAMMING
Page 167 · click to enlarge
Page 167

CHAPTER 7 PROGRAMMING

(c) Device used by the user

Device Description

X2E Variable parameter change command

X2F Positioning data write command

X30 Forward run command

X31 Reverse run command

D48 Positioning speed V1 (lower 16 bits)

D49 Positioning speed V1 (upper 16 bits)

M25 Variable parameter change

M26 Positioning data writing

M30 Speed control command pulse

M250 Z(P).REMTO instruction completion

M251 Z(P).REMTO instruction failure

M252 Z(P).REMTO instruction completion

M253 Z(P).REMTO instruction failure

7.4 When Using the Module in a Remote I/O Network 7.4.3 Major positioning control program

D46 Positioning mode

Page 168 of the Mitsubishi Electronics QD73A1 user manual — (d) Program example
Page 168 · click to enlarge
Page 168

(d) Program example

Mitsubishi Electronics QD73A1 — (d) Program example diagram (page 168)
Fig. 94 · (d) Program example

*1 Variable parameters and positioning data can be set through GX Works2 also. ( Page 108, Section 6.3, Page 109, Section 6.4) The sequence program that sets variable parameters and positioning data is unnecessary when the data were set through GX Works2.

Page 169 of the Mitsubishi Electronics QD73A1 user manual — (X1031) OFF
Page 169 · click to enlarge
Page 169

CHAPTER 7 PROGRAMMING

7.4.4 Fixed-feed operation program

This program executes positioning in the address increasing direction according to the specified movement amount

and speed. Execute fixed-feed operation by turning on Fixed-feed start command repeatedly. Use the current value

change function and positioning start in the absolute system. Suppose that parameter setting and OPR were

completed. ( Page 149, Section 7.4.1, Page 151, Section 7.4.2)

(1) Program detail

  • As X32 is turned on, the following positioning data are written.

Item Setting detail

Positioning address P1 20000pulse

Da.2

Positioning speed V1 1000pulse/s

Da.3

  • As X33 is turned on, the module starts fixed-feed operation.

(2) Execution condition

Check item Condition Note

Servo READY signal (READY) ON

Stop signal (STOP) OFF

Upper limit signal (FLS) ON

Lower limit signal (RLS) ON

QD73A1 READY signal (X1021) ON

BUSY signal (X1024) OFF

Excessive error signal (X1027) OFF

7.4 When Using the Module in a Remote I/O Network 7.4.4 Fixed-feed operation program

Error detection signal (X1028) OFF

Absolute positioning start complete signal

(X1031) OFF

Synchronization flag (X1034) ON

Absolute positioning start signal (Y1031) OFF

Stop signal (Y1037) OFF

PLC READY signal (Y103D) ON

When the positioning speed is set

exceeding " Speed limit

Pr.5

Buffer memory Positioning data No error

value", the positioning is executed

at " Speed limit value".

Pr.5

External I/O · signal · I/O signal

Page 170 of the Mitsubishi Electronics QD73A1 user manual — Device Description
Page 170 · click to enlarge
Page 170

(3) Device used by the user

Device Description

X32 Fixed-feed positioning data write command

X33 Fixed-feed start command

D50 Positioning address P1 (lower 16 bits)

D51 Positioning address P1 (upper 16 bits)

D52 Positioning speed V1 (lower 16 bits)

D53 Positioning speed V1 (upper 16 bits)

D100 New current value (lower 16 bits)

D101 New current value (upper 16 bits)

D104 Current value change request

D106 Current value change result check

M35 Variable parameter change

M55 Fixed-feed positioning data write command pulse

M56 Current value change result reading

M260 Z(P).REMTO instruction completion

M261 Z(P).REMTO instruction failure

M262 Z(P).REMTO instruction completion

M263 Z(P).REMTO instruction failure

M264 Z(P).REMTO instruction completion

M265 Z(P).REMTO instruction failure

M266 Z(P).REMFR instruction completion

M267 Z(P).REMFR instruction failure

Page 171 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 7 PROGRAMMING
Page 171 · click to enlarge
Page 171

CHAPTER 7 PROGRAMMING

(4) Program example

Mitsubishi Electronics QD73A1 — CHAPTER 7 PROGRAMMING diagram (page 171)
Fig. 95

7.4 When Using the Module in a Remote I/O Network 7.4.4 Fixed-feed operation program

Command to check the current value change again when it is incomplete.

*1 Positioning data can be set through GX Works2 also. ( Page 109, Section 6.4) The sequence program that sets positioning data is unnecessary when the data were set through GX Works2.

Page 172 of the Mitsubishi Electronics QD73A1 user manual — Device Description
Page 172 · click to enlarge
Page 172

7.4.5 JOG operation program

This program executes JOG operation while a JOG start command is on. Suppose that parameters are already set.

( Page 149, Section 7.4.1)

(1) Program detail

  • As X34 is turned on, JOG speed is written.

Item Setting detail

Cd.3

  • As X35 is turned on, the module executes forward JOG operation. As X36 is turned on, the module executes

reverse JOG operation.

(2) Execution condition

Check item Condition Note

Servo READY signal (READY) ON

Stop signal (STOP) OFF

Upper limit signal (FLS) ON

Lower limit signal (RLS) ON

QD73A1 READY signal (X1021) ON

BUSY signal (X1024) OFF

External stop signal (X102D) OFF

Synchronization flag (X1034) ON

Forward JOG start signal (Y1034) OFF

Reverse JOG start signal (Y1035) OFF

Stop signal (Y1037) OFF

PLC READY signal (Y103D) ON

When " JOG speed" is set

Cd.3

exceeding " Speed limit

Buffer memory JOG speed No error

Pr.5

Cd.3

value", the operation is executed at

" Speed limit value".

Pr.5

(3) Device used by the user

Device Description

X34 JOG speed write command

X35 Forward JOG command

X36 Reverse JOG command

D55 JOG speed (lower 16 bits)

D56 JOG speed (upper 16 bits)

M60 JOG speed writing

M270 Z(P).REMTO instruction completion

M271 Z(P).REMTO instruction failure

Show 5 more labels / short text on this page
JOG speed 10000pulse/s · External I/O · signal · I/O signal · M61 JOG command
Page 173 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 7 PROGRAMMING
Page 173 · click to enlarge
Page 173

CHAPTER 7 PROGRAMMING

(4) Program example

Mitsubishi Electronics QD73A1 — CHAPTER 7 PROGRAMMING diagram (page 173)
Fig. 96
Mitsubishi Electronics QD73A1 — CHAPTER 7 PROGRAMMING diagram (page 173)
Fig. 97

7.4 When Using the Module in a Remote I/O Network 7.4.5 JOG operation program

Page 174 of the Mitsubishi Electronics QD73A1 user manual — Device Description
Page 174 · click to enlarge
Page 174

7.4.6 Control change program

(1) Current value change program

This program changes the current value to "0".

(a) Program detail

As X37 is turned on, the current value is changed.

Item Setting detail

New current value 0pulse

Cd.1

(b) Execution condition

Check item Condition Note

WDT error, H/W error signal (X1020) OFF

BUSY signal (X1024) OFF

Error detection signal (X1028) OFF

Synchronization flag (X1034) ON

(c) Device used by the user

Device Description

X37 Current value change command

D100 New current value (lower 16 bits)

D101 New current value (upper 16 bits)

D104 Current value change request

D106 Current value change result check

M70 Variable parameter change

M71 Positioning data change

M280 Z(P).REMTO instruction completion

M281 Z(P).REMTO instruction failure

M282 Z(P).REMTO instruction completion

M283 Z(P).REMTO instruction failure

M284 Z(P).REMFR instruction completion

M285 Z(P).REMFR instruction failure

I/O signal

Page 175 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 7 PROGRAMMING
Page 175 · click to enlarge
Page 175

CHAPTER 7 PROGRAMMING

(d) Program example

Mitsubishi Electronics QD73A1 — CHAPTER 7 PROGRAMMING diagram (page 175)
Fig. 98

Command to check the current value change again when it is incomplete.

Mitsubishi Electronics QD73A1 — CHAPTER 7 PROGRAMMING diagram (page 175)
Fig. 99

7.4 When Using the Module in a Remote I/O Network 7.4.6 Control change program

Page 176 of the Mitsubishi Electronics QD73A1 user manual — Device Description
Page 176 · click to enlarge
Page 176

(2) Speed change program

This program changes positioning speed.

(a) Program detail

As X38 is turned on, positioning speed is changed.

Item Setting detail

Cd.2

New speed value 50000pulse/s

(b) Execution condition

Check item Condition Note

Servo READY signal (READY) ON

Stop signal (STOP) OFF

Upper limit signal (FLS) ON

Lower limit signal (RLS) ON

WDT error, H/W error signal (X1020) OFF

QD73A1 READY signal (X1021) ON

BUSY signal (X1024) ON

Excessive error signal (X1027) OFF

Error detection signal (X1028) OFF

Synchronization flag (X1034) ON

Stop signal (Y1037) OFF

PLC READY signal (Y103D) ON

When " New speed value" is

Cd.2

set exceeding " Speed limit

Pr.5

Buffer memory New speed value No error

Cd.2

value", the operation is executed at

" Speed limit value".

Pr.5

(c) Device used by the user

Device Description

X38 Speed change command

D102 New speed value (lower 16 bits)

D103 New speed value (upper 16 bits)

D105 Speed change request

D107 Speed change result check

M76 Speed change request check

M290 Z(P).REMTO instruction completion

M291 Z(P).REMTO instruction failure

M292 Z(P).REMTO instruction completion

M293 Z(P).REMTO instruction failure

M294 Z(P).REMFR instruction completion

M295 Z(P).REMFR instruction failure

Show 4 more labels / short text on this page
External I/O · signal · I/O signal · M75 Speed change
Page 177 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 7 PROGRAMMING
Page 177 · click to enlarge
Page 177

CHAPTER 7 PROGRAMMING

(d) Program example

Mitsubishi Electronics QD73A1 — CHAPTER 7 PROGRAMMING diagram (page 177)
Fig. 100

Command to check the speed change again when it is incomplete.

Mitsubishi Electronics QD73A1 — CHAPTER 7 PROGRAMMING diagram (page 177)
Fig. 101

7.4 When Using the Module in a Remote I/O Network 7.4.6 Control change program

Page 178 of the Mitsubishi Electronics QD73A1 user manual — (d) Program example
Page 178 · click to enlarge
Page 178

(3) Deviation counter clearing program

This program clears the deviation counter to 0.

(a) Program detail

As X39 is turned on, the deviation counter is cleared to 0.

Item Setting detail

Cd.4

Deviation counter clear command 1Clear the deviation counter

(b) Execution condition

Mitsubishi Electronics QD73A1 — (b) Execution condition diagram (page 178)
Fig. 102 · (b) Execution condition

(c) Device used by the user

Mitsubishi Electronics QD73A1 — (c) Device used by the user diagram (page 178)
Fig. 103 · (c) Device used by the user

(d) Program example

Mitsubishi Electronics QD73A1 — (d) Program example diagram (page 178)
Fig. 104 · (d) Program example

Read the completion of deviation counter clear from the QD73A1.

Command to check the deviation counter clear again when it is incomplete.

Page 179 of the Mitsubishi Electronics QD73A1 user manual — Device Description
Page 179 · click to enlarge
Page 179

CHAPTER 7 PROGRAMMING

7.4.7 Stop program during positioning

This program stops the positioning in execution.

(a) Program detail

As X3A is turned on, the module stops the positioning in execution.

(b) Device used by the user

Device Description

(c) Program example

Turn on Stop signal.

Turn off Stop signal.

7.4 When Using the Module in a Remote I/O Network 7.4.7 Stop program during positioning

X3A Stop command

Page 180 of the Mitsubishi Electronics QD73A1 user manual — Signal required for control
Page 180 · click to enlarge
Page 180

CHAPTER 8 OPR CONTROL

This chapter describes OPR control.

8.1 Overview of OPR Control

In "OPR control", a starting point (or OP) of major positioning control is set, and positioning is executed toward the

original point. Use this control to return a machine system at a position other than its OP to the OP when the QD73A1

turned on OPR request signal (X12) at power-on, or after a positioning stop.

OPR request signal (X12) turns on at the following timings.

  • When the power is turned on
  • When the CPU module was reset
  • When OPR starts
  • When Servo READY signal (READY) turns off while BUSY signal (X14) is on
  • When Servo READY signal (READY) turns off while BUSY signal (X14) is off

(only when "0: Clear the deviation counter when the servo ready signal is OFF." is selected for "Deviation

counter clear setting" in the switch setting)

(1) OPR method

The QD73A1 has two OPR methods so that an OP can be established in the optimum method (determination of

the OP position, or OPR completion) depending on the positioning system configuration or the application.

Set an OPR method in the switch setting. For the setting method, refer to the following.

Page 100, Section 6.2

OPR method Operation detail Reference

As the near-point dog turns on, deceleration starts. (The speed decelerates

to " Creep speed".) After the near-point dog turned off, the OPR is

Pr.12

completed at the operation stop with the first Zero signal*1, specifying the

Section 8.2

position as the OP.

As the near-point dog turns on, deceleration starts and the machine moves at

" Creep speed". From the position where the near-point dog turned on,

Pr.12

the machine moves the distance set in " Setting for the movement

Pr.13

Section 8.3

amount after near-point dog ON". Then, the OPR is completed at the

operation stop with the first Zero signal*1.

*1 Signal that is output as a single pulse at one motor revolution (e.g. Z-phase signal output from the drive unit)

(2) External I/O signals used for OPR control

: Necessary : Necessary as required

Signal required for control

Upper limit signal

OPR method

Near-point dog signal

(DOG) Zero signal

(FLS)/Lower limit signal

(RLS)

Show 6 more labels / short text on this page
Page 179, · Near-point dog method · Page 181, · Count method · Near-point dog method · Count method
Page 181 of the Mitsubishi Electronics QD73A1 user manual — (1) Operation chart
Page 181 · click to enlarge
Page 181

CHAPTER 8 OPR CONTROL

8.2 Near-point Dog Method

This section describes the operation overview of an OPR method, "near-point dog method".

(1) Operation chart

OPR starts.

(Acceleration starts in the direction set on "OPR direction setting" in the switch setting, and the machine moves at

" OPR speed".)

Pr.11

2 As the near-point dog turns on, deceleration starts.

3 The machine decelerates to " Creep speed", and subsequently moves at the creep speed.

Pr.12

(The near-point dog must be on during the deceleration. If the near-point dog turns off during the deceleration, the

OPR is completed at the first Zero signal input after the near-point dog OFF.)

4 Output from the QD73A1 stops at the first Zero signal after the near-point dog OFF.

5 Returning operation is executed by the coasting amount after Zero signal input, then OPR complete signal (X13) turns

on and OPR request signal (X12) turns off.

As in the following figure, after the near-point dog turned off, the position of the first Zero signal from the pulse

generator becomes the OP.

Mitsubishi Electronics QD73A1 — (1) Operation chart diagram (page 181)
Fig. 105 · (1) Operation chart

Returning operation is executed by the coasting amount after Zero signal input, and the OPR is completed.

Adjust the position where the near-point dog turns off so that it is closer to the center of Zero signals. If the position overlaps with Zero signal, the OPR stop position may deviate by one servomotor rotation.

Page 182 of the Mitsubishi Electronics QD73A1 user manual — (e) Outside the stroke limit range
Page 182 · click to enlarge
Page 182

(2) Precautions during operation

(a) Another OPR after the completion of OPR

If another OPR is attempted after the completion of OPR, the error "OPR complete signal ON at start" (error

code: 84) occurs.

(b) Positions of the near-point dog OFF and Zero signal

If the position where the near-point dog turns off is close to Zero signal, the Zero signal may be misread,

resulting in deviation of OP by one servomotor rotation. Adjust the position where the near-point dog turns off

so that it becomes closer to the center of Zero signals.

(c) OPR start from the near-point dog ON position

If an OPR start is attempted from the near-point dog ON position, the error "Near-point dog signal ON at start"

(error code: 74) occurs.

Return the workpiece to a position away from the near-point dog using JOG operation, then execute OPR.

(d) Another OPR after the reset of the CPU module

If the CPU module was reset after OPR control was completed and the near-point dog turned off, another OPR

can be started; however, the operation is executed at " OPR speed" to the position of the upper limit

Pr.11

switch (FLS) or the lower limit switch (RLS) since there is no near-point dog placed in the OPR direction.

(e) Outside the stroke limit range

If the workpiece moved outside the stroke limit range, the error "Outside the stroke limit range" (error code:

100. occurs; although, the operation continues. In this case, the OPR is completed normally if the near-point

dog is placed on the OPR direction.

Page 183 of the Mitsubishi Electronics QD73A1 user manual — (1) Operation chart
Page 183 · click to enlarge
Page 183

CHAPTER 8 OPR CONTROL

8.3 Count Method

This section describes the operation overview of an OPR method, "count method".

OPR in the count method can be executed also in case of the following.

  • OPR on the near-point dog ON
  • Another OPR after completion of OPR

(1) Operation chart

Mitsubishi Electronics QD73A1 — (1) Operation chart diagram (page 183)
Fig. 106 · (1) Operation chart

(Acceleration starts in the direction set on "OPR direction setting" in the switch setting, and the machine moves at

2 As the near-point dog turns on, deceleration starts.

3 The machine decelerates to " Creep speed", and subsequently moves at the creep speed.

4 Output from the QD73A1 stops at the first Zero signal after the machine moved by the amount set in " Setting

5 Returning operation is executed by the coasting amount after Zero signal input, then OPR complete signal (X13) turns

As in the following figure, after the machine moved the amount set in " Setting for the movement amount

after near-point dog ON", the position of the first Zero signal from the pulse generator becomes the OP.

Mitsubishi Electronics QD73A1 — (1) Operation chart diagram (page 183)
Fig. 107 · (1) Operation chart

Pr.11 OPR speed Deceleration at the near-point dog ON

Pr.13 Setting for the movement amount after near-point dog

Returning operation is executed by the coasting amount after Zero signal input, and the OPR is completed.

Adjust Setting for the movement amount after near-point dog ON so that it is closer to the center of Zero signals. If it overlaps with Zero signal, the OPR stop position may deviate by one servomotor rotation. One servomotor

Page 184 of the Mitsubishi Electronics QD73A1 user manual — (c) Outside the stroke limit range
Page 184 · click to enlarge
Page 184

(2) Precautions during operation

(a) Setting for the movement amount after near-point dog ON

Pr.13

If " Setting for the movement amount after near-point dog ON" is smaller than the deceleration distance

Pr.13

from " OPR speed" to " Creep speed", the error "Setting for the movement amount after near-point

Pr.11 Pr.12

dog ON Outside the setting range" (error code: 22) occurs, and the OPR does not start.

In addition, if the position after the move according to " Setting for the movement amount after near-point

Pr.13

dog ON" is close to Zero signal, the Zero signal may be misread, resulting in deviation of OP by one

servomotor rotation. Set " Setting for the movement amount after near-point dog ON" so that the position

Pr.13

after the move becomes closer to the center of Zero signals.

(b) OPR start while near-point dog is on

The operation is as follows.

1 OPR starts.

Pr.13 Setting for the movement

The workpiece moves in the direction that is

amount after near-point dog ON

opposite from the specified OPR direction at

" OPR speed".

Pr.11

3 As the near-point dog turns off, deceleration

starts.

4 After an operation stop, OPR starts in the

specified OPR direction.

As the near-point dog turns on, the

workpiece moves the amount set in

ON

" Setting for the movement amount

Pr.13

OFF

after near-point dog ON". Then, the OPR is

completed at the first Zero signal after the

move.

(c) Outside the stroke limit range

If the workpiece moved outside the stroke limit range, the error "Outside the stroke limit range" (error code:

100. occurs; although, the operation continues. In this case, the OPR is completed normally if the near-point

dog is placed on the OPR direction.

Near-point dog · Zero signal

Page 185 of the Mitsubishi Electronics QD73A1 user manual — t1 t2 t3
Page 185 · click to enlarge
Page 185

CHAPTER 8 OPR CONTROL

8.4 Operation Timing and Processing Time of OPR Control

This section explains the operation timing and processing time of OPR control.

ON

OFF

(Y20)

ON

OFF

(X14)

ON

OPR start complete signal

(X20)

OFF

t3 OPR request signal

ON

(X12)

OFF

ON

OFF

(X13)

*1 This is an indication of internal commands, and does not match with the actual analog output waveform.

The following values apply to t1 to t3.

t1 t2 t3

0.7 to 1.2ms 0 to 0.5ms 0 to 0.5ms

8.4 Operation Timing and Processing Time of OPR Control

Show 7 more labels / short text on this page
OPR control*1 · t · t1 · t2 · OPR start signal · BUSY signal · OPR complete signal
Page 186 of the Mitsubishi Electronics QD73A1 user manual — PLC READY
Page 186 · click to enlarge
Page 186

8.5 OPR Parameter Setting

For the QD73A1 to execute OPR, OPR parameters must be set. If the data are not set, default values are used for

control.

The default values are set also when the power was turned off and on, or when the CPU module was reset.

The following table lists the OPR parameters to be set, setting condition, and check timing.

Buffer

Setting item Setting range Default value Setting

Check timing of the

memory

condition

set data

address

(decimal)

OP address -2147483648 to

2147483647 pulse 0 pulse

Pr.10

OPR speed 1 to 4000000pulse/s 10000pulse/s 42

Pr.11

Creep speed 1 to 4000000pulse/s 1000pulse/s 44

PLC READY

When OPR start signal

Pr.12

(Y20) is turned on

must be off.

2147483647pulse 75 pulse 46

Pr.13

ON (set only for the

Show 6 more labels / short text on this page
signal (Y2D) · Setting for the · movement amount · 0 to · after near-point dog · count method)
Page 187 of the Mitsubishi Electronics QD73A1 user manual — Major positioning control Start signal Description Reference
Page 187 · click to enlarge
Page 187

CHAPTER 9 MAJOR POSITIONING CONTROL

CHAPTER 9 MAJOR POSITIONING CONTROL

"Major positioning control" is executed using "variable parameters" and "positioning data" stored in the QD73A1. The

position control mode or the speed-position control switch mode is executed by setting a variable parameter

" Positioning mode" and a positioning data item " Positioning pattern" and by starting the positioning data.

Pr.9 Da.1

9.1 Overview of Major Positioning Control

The following types of "major positioning control" are executed when a positioning start signal (Y21 to Y23) is turned

on.

Major positioning control Start signal Description Reference

Positioning is executed from the current

position to a specified position at a specified

speed.

Section 9.6.1 (1)

  • Positioning mode: 0

Pr.9

  • Positioning pattern: 0
  • Absolute positioning start

Da.1

Positioning is executed to the address

  • Forward start signal (Y22)

specified with " Positioning address

Da.2

P1" at " Positioning speed V1", then to

Da.3

  • Reverse start signal (Y23)

the address specified with " Positioning

Da.4

9.1 Overview of Major Positioning Control

address P2" at " Positioning speed V2"

Da.5

Section 9.6.1 (2)

by one positioning start signal.

  • Positioning mode: 0

Pr.9

  • Positioning pattern: 1

Da.1

Operation starts according to the positioning

speed set beforehand by one positioning start

signal, then the operation switches to position

control by Speed-position switching

command signal (CHANGE).

If the operation stopped by Stop signal after

  • Forward start signal (Y22)

the input of Speed-position switching

command signal (CHANGE), the positioning

Speed-position control switch mode

can be continued by requesting a restart.

  • Reverse start signal (Y23)

Section 9.6.2

In addition, the positioning address

(movement amount) can be changed if it is

before the input of Speed-position switching

command signal (CHANGE).

  • Positioning mode: 1

Pr.9

  • Positioning pattern: 0

Da.1

Show 19 more labels / short text on this page
Page 191, · Positioning control · [Buffer memory setting] · signal (Y21) · Position control · mode · (incremental positioning) · Two-phase · (incremental positioning) · Page 192, · trapezoidal · positioning control · [Buffer memory setting] · (Speed-position control · switchover) · Page 195, · (Speed-position control · switchover) · [Buffer memory setting]
Page 188 of the Mitsubishi Electronics QD73A1 user manual — (2) Sub functions for major positioning control
Page 188 · click to enlarge
Page 188

9.2 Data Required for Major Positioning Control

This section describes "positioning data" required for "major positioning control".

(1) Composition of positioning data and setting details

Positioning data Setting detail

Positioning pattern Select a control pattern of major positioning from "positioning control" or "two-phase trapezoidal

Da.1

positioning control".

Da.2

Positioning address P1 Set the address that is the destination of major positioning control.

Da.3

Positioning speed V1 Set the command speed of major positioning control.

In two-phase trapezoidal positioning control, set the destination address of after the move to the

Da.4

address set to " Positioning address P1".

Da.2

In two-phase trapezoidal positioning control, set the command speed to move to the address set to

Da.5

" Positioning address P2".

Da.4

The settings of to depend on " Positioning mode" and " Positioning pattern".

Da.1 Da.5 Pr.9 Da.1

( Page 187, Section 9.3)

(2) Sub functions for major positioning control

For details on "sub functions" that can be combined with major positioning control, refer to the following.

Page 29, Section 3.3 (4)

For details on each sub function, refer to the following.

Page 208, CHAPTER 11

Positioning address P2 · Positioning speed V2

Page 189 of the Mitsubishi Electronics QD73A1 user manual — Positioning data
Page 189 · click to enlarge
Page 189

CHAPTER 9 MAJOR POSITIONING CONTROL

9.3 Relation Between Each Control and Positioning Data

Setting items and details of positioning data depend on the settings of a positioning data item " Positioning

Da.1

pattern" and a variable parameter " Positioning mode".

Pr.9

The following table shows the positioning data setting items for each type of control.

Settings of " Positioning mode"

Pr.9

Positioning data

0: Position control mode 1: Speed-position control

switch mode

0. Positioning control

Da.1

1. Two-phase trapezoidal

Da.2

Da.3

Da.4

Da.5

: Set always

: Set only for two-phase trapezoidal positioning control

: Setting not required (The setting is ignored. Use the default value or a value that does not cause an error.)

For details on each control and setting, refer to the following.

Page 190, Section 9.6

9.3 Relation Between Each Control and Positioning Data

Show 7 more labels / short text on this page
Positioning · pattern · positioning control · Positioning address P1 · Positioning speed V1 · Positioning address P2 · Positioning speed V2
Page 190 of the Mitsubishi Electronics QD73A1 user manual — (2) Incremental system
Page 190 · click to enlarge
Page 190

9.4 Specifying a Positioning Address

This section describes systems to specify a position for control using positioning data.

(1) Absolute system

Positioning is executed using the current address as the start address and the address set with

" Positioning address P1" as the end address.

Da.2

End point Address 100

OP (Reference point) 100 150 300

A point B point C point

Within the stroke limit range

(2) Incremental system

Positioning is executed from the current address (start address) by the movement amount set in

" Positioning address P1".

Da.2

The moving direction depends on the start signal to turn on: Forward start signal (Y22) or Reverse start signal

(Y23).

End point Movement amount

Movement amount +50 Movement amount -100

OP (Reference point) 100

Within the stroke limit range

Show 18 more labels / short text on this page
Start point · Address 100 · Address · 150 Address 300 · Address 150 · Address 100 · Address 150 · Movement amount · Start point · +100 · Movement amount +100 · Movement amount · Movement · +100 · amount · A point · B point · C point
Page 191 of the Mitsubishi Electronics QD73A1 user manual — (2) Precaution
Page 191 · click to enlarge
Page 191

CHAPTER 9 MAJOR POSITIONING CONTROL

9.5 Checking the Current Value

In the QD73A1, two types of address are used to indicate position.

(1) Addresses to be used

The two types of address, "current feed value" and "actual current value", are stored to the monitor data area.

They can be monitored when necessary.

Item Description Update cycle

  • This is the value stored in " Current feed value".

Md.1

  • The address established through OPR is the value of reference.
  • The address can be changed through a current value change.
  • This is the value stored in " Actual current value".

Md.2

0.5ms

  • The actual servomotor movement amount calculated based on feedback pulses

is stored as an actual current value (the number of feedback pulses).

(Actual current value = Current feed value - Accumulated pulses in the deviation

(2) Precaution

When the value stored in " Current feed value" or " Actual current value" is used for control, the

Md.1 Md.2

update timing of the buffer memory area may be in error by 0.5ms.

9.5 Checking the Current Value

Current feed value · Actual current value · counter)

Page 192 of the Mitsubishi Electronics QD73A1 user manual — (2) Stop and restart during positioning
Page 192 · click to enlarge
Page 192

9.6 Details of Major Positioning Control

This section describes details on the position control mode (positioning control and two-phase trapezoidal positioning

control) and the speed-position control switch mode.

(1) Precautions

(a) Dwell-time function

The QD73A1 does not have the dwell-time function. When dwell-time is necessary, start the next operation

using the timer in the sequence program once the specified period of time passed after Positioning complete

signal (X15) turned on.

(b) Combined use of incremental system and absolute system

The QD73A1 controls the current value during positioning. If incremental system positioning or combined

positioning of incremental system and absolute system is repeated, the workpiece may move outside the

stroke limit range and an error may occur. If an error occurs, change the current value to the one within the

stroke limit range.

(2) Stop and restart during positioning

Refer to the following.

Page 230, CHAPTER 12

Page 193 of the Mitsubishi Electronics QD73A1 user manual — ON
Page 193 · click to enlarge
Page 193

CHAPTER 9 MAJOR POSITIONING CONTROL

9.6.1 Position control mode

In the position control mode, positioning is executed toward the positioning address specified with positioning data at

the specified speed.

There are two types of control in the position control mode.

  • Positioning control ( Page 191, Section 9.6.1 (1))
  • Two-phase trapezoidal positioning control ( Page 192, Section 9.6.1 (2))

There are two systems to specify a positioning address: the absolute system in which a positioning end address is

specified and the incremental system in which movement amount from a start address to an end address is specified.

Specify the absolute system or the incremental system using one of the following start signals.

Start signal Positioning system

Absolute positioning start signal (Y21) Positioning start in the absolute system

Forward start signal (Y22) Forward start in the incremental system (address increasing)

Reverse start signal (Y23) Reverse start in the incremental system (address

(1) Positioning control

Set a positioning address and positioning speed for this type of control. Absolute system positioning or

incremental system positioning is executed by a positioning start command.

(a) Operation of positioning control

The operation is as follows.

Da.2

9.6 Details of Major Positioning Control 9.6.1 Position control mode

Da.3

ON

OFF

ON

(X14)

OFF

ON

(X15)

OFF

Executed by the QD73A1

Show 8 more labels / short text on this page
decreasing) · Positioning address P1 · Positioning speed V1 · t · Positioning start signal · (Y21 to Y23) · BUSY signal · Positioning complete signal
Page 194 of the Mitsubishi Electronics QD73A1 user manual — ON
Page 194 · click to enlarge
Page 194

(b) Positioning data setting

The following table lists the positioning data to be set, setting condition, and check timing.

Buffer

Setting item Setting range Default

value Setting condition Check timing

memory

of the set data

address

(decimal)

0. Positioning control

0 The data can be set anytime.

Da.1

1. Two-phase trapezoidal

rise (ON) of a positioning

Absolute system:

start signal (Y21 to Y23) are

used for the operation. If the

data are written when BUSY

Da.2

Incremental system:

signal (X14) is on, the data

Y23) is turned on

will be accepted at the rise

(ON) of the next positioning

V1 1 to 4000000pulse/s 0pulse/s 304

Da.3

start signal (Y21 to Y23).

(2) Two-phase trapezoidal positioning control

Set positioning addresses (P1 and P2) and positioning speed (V1 and V2) for this type of control. Positioning of

the absolute system or the incremental system is executed first to the positioning address P1 at the positioning

speed V1, then to the positioning address P2 at the positioning speed V2 by one positioning start command.

(a) Operation of two-phase trapezoidal positioning control

The operation is as follows.

Positioning address P1 Da.2 Positioning address P2 Da.4

Positioning speed V1 Da.3

Positioning speed V2 Da.5

ON

OFF

ON

(X14)

OFF

ON

(X15)

OFF

Executed by the QD73A1

Show 20 more labels / short text on this page
Positioning pattern · positioning control · Positioning address · When a · P1 (movement · -2147483648 to · positioning start · 0pulse 302 · amount for the · 2147483647pulse · signal (Y21 to · incremental · system) · 0 to 2147483647pulse · Positioning speed · t · Positioning start signal · (Y21 to Y23) · BUSY signal · Positioning complete signal
Page 195 of the Mitsubishi Electronics QD73A1 user manual — (d) Positioning speed V1 and V2
Page 195 · click to enlarge
Page 195

CHAPTER 9 MAJOR POSITIONING CONTROL

(b) Deceleration distance

If the movement amount from the positioning address P1 to the positioning address P2 is less than the

deceleration distance from the positioning address P1, two-phase trapezoidal positioning control is not formed.

In this case, the deceleration from the positioning speed V1 starts before the workpiece reaches the positioning

address P1 so that the operation stops at the positioning address P2.

Positioning speed V1 Da.3

Positioning speed V1 Da.3

Da.5 Positioning speed V2

Da.5 Positioning speed V2

Deceleration stop fails.

Da.2

Da.2

Da.4

Da.4

Deceleration distance from " Positioning address P1"

Da.2

To execute two-phase trapezoidal positioning, set the positioning data so that the deceleration distance from

the positioning address P1 does not exceed the movement amount from the positioning address P1 to the

positioning address P2.

(c) Two-phase trapezoidal positioning control in the absolute system

To execute two-phase trapezoidal positioning control in the absolute system, the positioning direction from

" Positioning address P1" to " Positioning address P2" and the positioning direction from the

Da.2 Da.4

current value to " Positioning address P1" must be the same.

Da.2

9.6 Details of Major Positioning Control 9.6.1 Position control mode

If not, the error "Two-phase trapezoidal positioning address error" (error code: 31) occurs, and the two-phase

trapezoidal positioning control does not start.

Setting example Moving direction from the current value to

the positioning address P1

Da.2 Da.4

Positioning address

Positioning address

Address increasing

Address decreasing

P1

P2

direction

direction

10000 5000 Error Positioning executed

10000 15000 Positioning executed Error

(d) Positioning speed V1 and V2

Any value within the setting range can be set in " Positioning speed V1" and " Positioning speed

Da.3 Da.5

V2" regardless the relation between the two setting values.

Show 4 more labels / short text on this page
Positioning address P1 · Positioning address P1 · Positioning address P2 · Positioning address P2
Page 196 of the Mitsubishi Electronics QD73A1 user manual — Buffer
Page 196 · click to enlarge
Page 196

(e) Positioning data setting

The following table lists the positioning data to be set, setting condition, and check timing.

Buffer

Setting item Setting range Default

value Setting condition Check timing

memory

of the set data

address

(decimal)

0. Positioning control

Da.1

1. Two-phase trapezoidal

Absolute system:

The data can be set anytime.

Da.2

Incremental system:

rise (ON) of a positioning

start signal (Y21 to Y23) are

used for the operation. If the

V1 1 to 4000000pulse/s 0pulse/s 304

Da.3

data are written when BUSY

signal (X14) is on, the data

Y23) is turned on

Absolute system:

will be accepted at the rise

(ON) of the next positioning

start signal (Y21 to Y23).

Da.4

Incremental system:

V2 1 to 4000000pulse/s 0pulse/s 308

Da.5

Show 27 more labels / short text on this page
Positioning pattern · positioning control · Positioning · address P1 · -2147483648 to · (movement · 0pulse 302 · 2147483647pulse · amount for the · incremental · 0 to 2147483647pulse · system) · When a · positioning start · Positioning speed · signal (Y21 to · Positioning · address P2 · -2147483648 to · (movement · 0pulse 306 · 2147483647pulse · amount for the · incremental · 0 to 2147483647pulse · system) · Positioning speed
Page 197 of the Mitsubishi Electronics QD73A1 user manual — OFF
Page 197 · click to enlarge
Page 197

CHAPTER 9 MAJOR POSITIONING CONTROL

9.6.2 Speed-position control switch mode

In the speed-position control switch mode, pulses that correspond to the specified positioning speed are output in the

direction specified by a start signal. Then, once Speed-position switching command signal (CHANGE) is input, the

operation switches to position control with the specified movement amount.

The speed-position control switch mode operates with the incremental system in which movement amount from a start

address to an end address is specified.

Specify a forward start or a reverse start using one of the following signals.

Start signal Positioning system

Forward start signal (Y22) Forward start (address increasing)

Reverse start signal (Y23) Reverse start (address decreasing)

(1) Switchover from speed control to position control

To switch the operation from speed control to position control, Speed-position switching enable signal (Y2C) must

be turned on before inputting Speed-position switching command signal (CHANGE).

If Speed-position switching command signal (CHANGE) is input when Speed-position switching enable signal

(Y2C) is off, the speed control continues without being switched to position control. The operation switches to

position control when Speed-position switching command signal (CHANGE) is input after Speed-position

switching enable signal (Y2C) was turned on.

(2) Operation of the speed-position control switch mode

The operation is as follows.

Movement amount set to " Positioning address P1" Da.2

9.6 Details of Major Positioning Control 9.6.2 Speed-position control switch mode

Positioning speed V1 Da.3

Speed control Position control

ON

(Y22, Y23)

OFF

ON

(X14)

OFF

ON

OFF

ON

OFF

ON

Speed-position switching command signal (CHANGE)

OFF

Current feed value Md.1 P1

Executed by the QD73A1

Show 7 more labels / short text on this page
t · Positioning start signal · BUSY signal · Positioning complete · signal (X15) · Speed-position switching · enable signal (Y2C)
Page 198 of the Mitsubishi Electronics QD73A1 user manual — (6) Two-phase trapezoidal positioning control and speed-position control
Page 198 · click to enlarge
Page 198

(3) " Current feed value" and " Actual current value"

Md.1 Md.2

In " Current feed value" and " Actual current value", 0 is set at the start of the speed-position control

Md.1 Md.2

switch mode, and the settings are not updated during speed control.

They are updated once the operation switched to position control by the input of Speed-position switching

command signal (CHANGE).

(4) Positioning error in the speed-position control switch mode

In the speed-position control switch mode, operation switches to position control by an input of Speed-position

switching command signal (CHANGE) during speed control. The process from the signal input to the completion

of switchover to position control takes some time, resulting in a positioning error by pulses output during the

process.

The process time varies by approximately 2ms including the response delay of Speed-position switching

command signal (CHANGE).

Mitsubishi Electronics QD73A1 — (4) Positioning error in the speed-position control switch mode diagram (page 198)
Fig. 108 · (4) Positioning error in the speed-position control…

Movement amount set to " Positioning address P1" Da.2

(5) " Positioning address P1"

Da.2

Set " Positioning address P1" so that its setting value becomes greater than the value of the distance

Da.2

obtained using the following formula. If not, the positioning stops exceeding the specified movement amount.

Mitsubishi Electronics QD73A1 — (5) " Positioning address P1" diagram (page 198)
Fig. 109 · (5) " Positioning address P1"

Distance to decelerate from " Positioning speed V1" Da.3

(6) Two-phase trapezoidal positioning control and speed-position control

switchover

A speed-position control switchover cannot be performed in two-phase trapezoidal positioning control.

Page 199 of the Mitsubishi Electronics QD73A1 user manual — (8) Speed-position movement amount change
Page 199 · click to enlarge
Page 199

CHAPTER 9 MAJOR POSITIONING CONTROL

Input Speed-position switching command signal (CHANGE) at the area where the speed is stable (constant speed status). When a servomotor is used, the actual movement amount after the switchover to position control is "Set movement amount + Accumulated pulse amount". If the signal is input during acceleration or deceleration, the operation stop position varies due to the variation in the accumulated pulse amount.

(7) Parameter and positioning data setting

The following table lists the parameter and positioning data to be set, setting condition, and check timing.

Set other parameters if necessary.

Buffer

Setting item Setting range Default

value Setting condition Check timing

memory

of the set data

address

(decimal)

0. Position control mode

The data can be set

1. Speed-position control switch

anytime.

Pr.9

the rise (ON) of a

0 to 2147483647pulse 0pulse 302

Da.2

(Y22, Y23) are used for

the operation. If the data

are written when BUSY

signal (X14) is on, the

data will be accepted at

speed V1 1 to 4000000pulse/s 0pulse/s 304

Da.3

the rise (ON) of the next

(Y22, Y23).

9.6 Details of Major Positioning Control 9.6.2 Speed-position control switch mode

(8) Speed-position movement amount change

The movement amount for position control can be changed during speed control of the speed-position control

switch mode.

Set the new movement amount in " New speed-position movement amount" using a sequence program

Cd.6

during speed control. The value in " New speed-position movement amount" is reflected as the movement

Cd.6

amount for position control at the input of Speed-position switching command signal (CHANGE).

Show 13 more labels / short text on this page
Positioning mode · mode · Positioning · positioning start signal · address P1 · When a · (movement · positioning start · amount) · signal (Y22, Y23) · is turned on · Positioning · positioning start signal
Page 200 of the Mitsubishi Electronics QD73A1 user manual — (9) Operation of speed control
Page 200 · click to enlarge
Page 200

(a) Operation of a speed-position movement amount change

The operation is as follows.

v Speed control Position control

Movement amount (P1) set to " New speed-position movement amount"

Cd.6

Movement amount can be changed

Movement amount cannot be changed

ON

Speed-position switching command signal (CHANGE)

OFF

The change after Speed-position switching command signal (CHANGE) was turned on is ignored.

Cd.6 New speed-position

P1 P2

P1 becomes the movement amount in position control.

(b) New speed-position movement amount

Cd.6

The setting is cleared to 0 when the next operation starts.

(c) Data setting

The following table lists the data to be set, setting condition, and check timing.

Buffer

Setting item Setting range Default

value Setting condition Check timing of

memory

the set data

address

(decimal)

The data can be set when

BUSY signal (X14) is on

At the input of

during speed control, and

Cd.6

besides before the input of

command signal (CHANGE).

If " New speed-position movement amount" is a value that moves the workpiece outside the stroke limit

Cd.6

range, the error "Movement outside the stroke limit range" (error code: 87) occurs at the input of Speed-

position switching command signal (CHANGE), and the set new movement amount is ignored. (The value in

" Positioning address P1" (movement amount) is used.)

Da.2

(9) Operation of speed control

Operation can stay as speed control in the speed-position control switch mode when one of the following

conditions is satisfied.

  • Not to input Speed-position switching command signal (CHANGE)
  • Not to turn on Speed-position switching enable signal (Y2C)

During speed control, the stroke limit function cannot be used since " Current feed value" is not updated. A

Md.1

stroke range is from the lower limit switch (RLS) to the upper limit switch (FLS).

Show 10 more labels / short text on this page
t · movement amount · New speed-position · 1 to · Speed-position · 2147483647pulse 0pulse · movement amount · switching command · Speed-position switching · signal (CHANGE)
Page 201 of the Mitsubishi Electronics QD73A1 user manual — t1 t2 t3
Page 201 · click to enlarge
Page 201

CHAPTER 9 MAJOR POSITIONING CONTROL

9.7 Operation Timing and Processing Time of Major Positioning Control

This section explains the operation timing and processing time of major positioning control.

Major positioning control*1

ON

OFF

OFF

(X14)

OFF

ON

(X15)

OFF

ON

Positioning start complete signal

OFF

ON

OFF

(X13)

*1 This is an indication of internal commands, and does not match with the actual analog output waveform.

The following values apply to t1 to t3.

9.7 Operation Timing and Processing Time of Major Positioning Control

t1 t2 t3

0.7 to 1.2ms 0 to 0.5ms 0 to 0.5ms

Show 10 more labels / short text on this page
t · t1 · t2 · Positioning start signal · (Y21 to Y23) · BUSY signal · Positioning complete signal · (X21 to X23) · OPR complete signal · t3
Page 202 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 10 JOG OPERATION
Page 202 · click to enlarge
Page 202

CHAPTER 10 JOG OPERATION

The QD73A1's "JOG operation" can move the workpiece without using positioning data, but according to signal inputs

and specified movement amount. Use this function for the following.

  • To check the connection of a positioning system
  • To obtain the address of positioning data
  • To move the workpiece in the direction where a limit signal turns on if operation stopped when a limit signal

"JOG operation" moves the workpiece in the specified direction at the specified speed while Forward JOG start signal

(Y24) or Reverse JOG start signal (Y25) is on.

turned off

Page 203 of the Mitsubishi Electronics QD73A1 user manual — (Y25)
Page 203 · click to enlarge
Page 203

CHAPTER 10 JOG OPERATION

10.1 Operation of JOG Operation

Once JOG speed is set and while a JOG start signal is turned on through a sequence program, the QD73A1 executes

JOG operation in the specified direction by outputting analog voltage to the drive unit.

Choose forward run or reverse run using JOG start signals.

Start signal Operation direction

Forward JOG start signal (Y24) Address increasing direction

Reverse JOG start signal (Y25) Address decreasing direction

(1) Operation of JOG operation

The following is an example of JOG operation.

1 As a JOG start signal is turned on, acceleration starts in the specified direction according to " Acceleration time".

Pr.6

BUSY signal (X14) turns on at this time.

2 As the accelerating operation reaches the speed set in " JOG speed", the move continues maintaining the

Cd.3

speed. The workpiece moves at the constant speed between 2 to 3 in the graph below.

3 As the JOG start signal is turned off, deceleration starts from the speed set in " JOG speed" according to

Cd.3

" Deceleration time".

Pr.7

4 As the speed reaches 0, the operation stops. BUSY signal (X14) turns off at this time.

JOG speed Cd.3

Deceleration according to " Deceleration time" Acceleration according to " Acceleration time"

Pr.7 Pr.6

1 2 3 4

10.1 Operation of JOG Operation

ON

OFF

(Y2D)

ON

(X11)

OFF

ON

Forward JOG start signal

(Y24)

OFF

ON

Reverse JOG start signal

(Y25)

OFF

ON ON

(X14)

OFF

Executed by the QD73A1

Speed can be changed by writing data to the control change area of the buffer memory using a sequence

program.

For details, refer to the following.

Page 218, Section 11.6

Show 5 more labels / short text on this page
Forward JOG operation · Reverse JOG operation · PLC READY signal · QD73A1 READY signal · BUSY signal
Page 204 of the Mitsubishi Electronics QD73A1 user manual — (c) When the stroke limit range was exceeded during JOG operation
Page 204 · click to enlarge
Page 204

(2) Range of JOG operation

The following figure shows the range of JOG operation.

Lower limit switch (RLS)

Upper limit switch (FLS)

0 2147483647 0 2147483647

Error (error code100)
Error (error code100) Within the stroke limit range

Underflow signal (X1A) ON

Overflow signal (X19) ON

Overflow signal (X19) ON

Underflow signal (X1A) ON

Overflow signal (X19) ON

Deceleration stop Deceleration stop

(a) Range in which JOG operation can be executed

JOG operation can be executed within the range between the upper limit switch (FLS) and the lower limit

switch (RLS). Note that the stroke limit upper limit and lower limit are ignored in JOG operation.

JOG operation decelerates and stops if Upper limit signal (FLS) or Lower limit signal (RLS) turned off during

the operation.

(b) When " Current feed value" exceeded the QD73A1's control range during JOG

Md.1

operation

When the current feed value exceeded the QD73A1's control range (-2147483648 to 2147483647), Overflow

signal (X19) or Underflow signal (X1A) turns on, and " Current feed value" varies again as in the following

Md.1

figure.

Current feed value Md.1

Reset Overflow signal (X19) or Underflow signal (X1A) by turning on Overflow reset signal (Y29) or Underflow

reset signal (Y2A).

(c) When the stroke limit range was exceeded during JOG operation

The error "Outside the stroke limit range" (error code: 100) occurs.

Show 12 more labels / short text on this page
Stroke limit · Stroke limit · 2147483647 · lower limit · upper limit · -2147483648 -2147483648 · (Positioning range) · QD73A1 control range · JOG operation range · 2147483647 · t · -2147483648
Page 205 of the Mitsubishi Electronics QD73A1 user manual — OFF
Page 205 · click to enlarge
Page 205

CHAPTER 10 JOG OPERATION

(d) When the upper limit switch (FLS) or the lower limit switch (RLS) turned off

The error "Upper limit signal OFF while BUSY" (error code: 91) or the error "Lower limit signal OFF while

BUSY" (error code: 92) occurs.

If operation decelerated and stopped due to the upper limit switch (FLS) or the lower limit switch (RLS), JOG

operation can be executed in the opposite direction (direction back to the normal range) after resetting the

error. (If the JOG start signal for the erroneous direction is turned on, the error occurs again.)

JOG operation possible JOG operation not possible

Upper limit signal (FLS)

ON

or Lower limit signal (RLS)

OFF

(3) Precautions during operation

  • Set a small value in " JOG speed" first to check the operation, then change it to greater values

Cd.3

gradually for safe operation.

  • If " JOG speed" is 0, the error "JOG speed Outside the setting range" (error code: 41) occurs, and the

Cd.3

JOG operation does not start.

  • If " JOG speed" exceeds " Speed limit value", the operation is executed at the speed set in

Cd.3 Pr.5

" Speed limit value", but the error "JOG speed Outside the setting range" (error code: 41) occurs.

Pr.5

10.1 Operation of JOG Operation

JOG operation · Deceleration stop · t

Page 206 of the Mitsubishi Electronics QD73A1 user manual — (Y25)
Page 206 · click to enlarge
Page 206

(4) JOG start timing

  • During deceleration after a JOG start signal was turned off, if the JOG start signal for the same direction is

turned on, JOG operation starts again accelerating its speed.

ON

Forward JOG start signal

(Y24)

OFF

ON

(X14)

OFF

Executed by the QD73A1

  • During deceleration after a JOG start signal was turned off, if the JOG start signal for the opposite direction

is turned on, JOG operation starts in the opposite direction after the completion of deceleration.

ON

Forward JOG start signal

(Y24)

OFF

ON

Reverse JOG start signal

(Y25)

OFF

ON

(X14)

OFF

BUSY signal (X14) turns off for 0.5ms when switching. Executed by the QD73A1

Show 4 more labels / short text on this page
t · BUSY signal · t · BUSY signal
Page 207 of the Mitsubishi Electronics QD73A1 user manual — (6) Monitoring JOG operation
Page 207 · click to enlarge
Page 207

CHAPTER 10 JOG OPERATION

  • During deceleration after a JOG start signal was turned off, if OPR start signal (Y20) or a positioning start

signal (Y21 to Y23) is turned on, an error occurs and the operation does not start.

ON

Forward JOG start signal (Y24)

OFF

ON

OFF

OPR start signal (Y20)

ON

or Positioning start signal (Y21 to Y23)

OFF

Error code (ERR.1) Md.3

81 (BUSY signal ON at start)

Executed by the QD73A1

  • If the JOG start signal for the opposite direction is turned on during JOG operation, the error "BUSY signal

ON at start" (error code: 81) occurs and the operation in the opposite direction is not executed.

  • If Forward JOG start signal (Y24) and Reverse JOG start signal (Y25) are turned on at the same time, the

error "BUSY signal ON at start" (error code: 81) occurs and forward JOG operation is executed.

(5) Sub functions for JOG operation

For details on "sub functions" that can be combined with JOG operation, refer to the following.

Page 29, Section 3.3 (4)

For details on each sub function, refer to the following.

10.1 Operation of JOG Operation

Page 208, CHAPTER 11

(6) Monitoring JOG operation

To directly monitor the buffer memory using GX Works2, refer to the following.

Page 89, Section 5.6

t · BUSY signal (X14)

Page 208 of the Mitsubishi Electronics QD73A1 user manual — t1 t2 t3
Page 208 · click to enlarge
Page 208

10.2 Operation Timing and Processing Time of JOG Operation

This section explains the operation timing and processing time of JOG operation.

ON

OFF

(Y24, Y25)

ON

OFF

(X14)

ON

(X15)

OFF

*1 This is an indication of internal commands, and does not match with the actual analog output waveform.

The following values apply to t1 to t3.

t1 t2 t3

0.7 to 1.2ms 0 to 0.5ms 0 to 0.5ms

Show 8 more labels / short text on this page
JOG operation*1 · t · t1 · t2 · t3 · JOG start signal · BUSY signal · Positioning complete signal
Page 209 of the Mitsubishi Electronics QD73A1 user manual — Buffer
Page 209 · click to enlarge
Page 209

CHAPTER 10 JOG OPERATION

10.3 Data Setting for JOG Operation

To execute JOG operation, certain data must be set and stored in the buffer memory areas.

The following table lists the JOG data to be set, setting condition, and check timing.

Buffer

Check timing

Setting item Setting range Default

memory

value Setting condition

of the set

address

data

(decimal)

JOG speed 1 to 4000000pulse/s 0pulse/s The data can be set anytime.

Cd.3

rise (ON) of a JOG start

(Set in the unit of

signal (Y24, Y25) are used

Pr.5

10pulse/s.)

for the operation. If the data

are written when BUSY

Pr.6

signal (X14) is on, the data

2 to 9999ms 300ms

will be accepted at the rise

Pr.7

(ON) of the next JOG start

signal (Y24, Y25).

10.3 Data Setting for JOG Operation

Show 9 more labels / short text on this page
10 to 4000000pulse/s · Speed limit value · When a JOG · pulse/s · start signal · (Y24, Y25) is · Acceleration time · turned on · Deceleration time 23
Page 210 of the Mitsubishi Electronics QD73A1 user manual — Sub function Description Reference
Page 210 · click to enlarge
Page 210

CHAPTER 11 CONTROL SUB FUNCTIONS

Functions referred to as "sub function" compensate or limit control, or add functions at the execution of major

positioning functions. Execute these sub functions by setting parameters or through a sequence program for them.

The following functions are referred to as "sub function".

Sub function Description Reference

Electronic gear function This function controls moving distance and speed by multiplying

command pulse output of the QD73A1.

Section 11.1

This function limits command speed to the value set in

" Speed limit value".

Section 11.2

Pr.5

This function controls operation not to execute positioning when

a command that moves the workpiece outside the specified

Section 11.3

stroke limit range is given.

This function decelerates and stops operation according to the

Upper limit switch (FLS)/lower limit

detection on limit switches placed at the upper and lower stroke

Section 11.4

limits.

Current value change function This function changes the value set in " Current feed

Md.1

value" to a specified value.

Section 11.5

Speed change function This function changes speed during major positioning control or

JOG operation.

Section 11.6

This function clears the accumulated pulses in the deviation

counter. When the servomotor power was turned off due to an

Deviation counter clear function

emergency stop during positioning, clearing the accumulated

Section 11.7

pulses in the deviation counter prevents servomotor rotation at

power recovery.

This function turns on In-position signal (X16) while the

accumulated pulse amount in the deviation counter is within the

specified in-position range (1 to 20479pulse). In-position signal

Section 11.8

(X16) can be used as the signal right before positioning

completion.

This function outputs an alert and immediately stops the

positioning when the accumulated pulses reached the amount

Accumulated pulse error detection

specified by the user before the pulses exceed the amount set

Section 11.9

in "Accumulated pulse setting" in the switch setting and an

excessive error occurs.

Show 24 more labels / short text on this page
Functions to · Page 209, · compensate · control · Page 211, · Speed limit function · Functions to · Page 213, · Stroke limit function · limit control · Page 215, · switch (RLS) function · Page 217, · Page 218, · Functions to · change control · details · Page 220, · Page 221, · In-position function · Other · functions · Page 223, · function
Page 211 of the Mitsubishi Electronics QD73A1 user manual — 50 50 1 CDV CMX
Page 211 · click to enlarge
Page 211

CHAPTER 11 CONTROL SUB FUNCTIONS

11.1 Electronic Gear Function

The "electronic gear function" controls machine movement amount per one command pulse by multiplying command

pulse output of the QD73A1.

Positioning is much more flexible with the use of this function, eliminating the process of selecting a detector according

to the machine system.

(1) Details of the electronic gear function

Machine movement amount per one pulse is adjusted inside the QD73A1.

Electronic gear is active on all of OPR control, major positioning control, and JOG operation.

QD73A1

Number of command pulses

CMX

CDV

Set numerator and denominator of command pulse multiplication for electronic gear to parameters.

Satisfy the following condition when setting a numerator (CMX) and a denominator (CDV).

50 50 1 CDV CMX

If the setting range is exceeded, the error "Denominator of command pulse multiplication for electronic gear

11.1 Electronic Gear Function

Outside the setting range" (error code: 3) occurs.

When the electronic gear function is used, positioning speed and movement amount are multiplied by the

specified value.

When there are decimal pulses, the fractions are maintained inside and accumulated for the next command.

The following is an example of the use of electronic gear.

Ex. A positioning system using the following worm gear

  • Worm gear lead: 10mm
  • Feedback pulses from the servomotor: 12000pulse/rev

When the electronic gear function is not used, the feed rate (movement amount per pulse) has fractions.

= = 12000 10 mm/pulse 0.000833

In this system, the fractions can be avoided using the electronic gear function and setting numerator and

denominator as followsCMX/CDV = 12

= = 12 0.01mm/pulse 12000 ' 10

Show 15 more labels / short text on this page
Drive unit · Speed command · Electronic · Deviation · D/A converter · Setting data · gear · counter · Servo amplifier · Accumulated pulses · Analog voltage · Multiplication · Command · feedback pulse · pulse
Page 212 of the Mitsubishi Electronics QD73A1 user manual — PLC READY
Page 212 · click to enlarge
Page 212

(2) Precautions for control

  • Execute OPR without fail after resetting the CPU module. If not, a positioning error occurs by the fractions of

electronic gear that were not output during positioning before the CPU reset.

  • When the positioning speed value that was multiplied by the set value of electronic gear exceeds the speed

limit value, the limit value is ignored. On the other hand, if the speed exceeds 4Mpulse/s, the maximum

value of command frequency, the error "Outside the command frequency range" (error code: 104) occurs. In

this case, the speed is 4Mpulse/s, resulting in a positioning error. To avoid this case, satisfy the following

condition when setting positioning speed and electronic gear: Positioning speed × Electronic gear

(3) Setting the electronic gear function

The following table lists the data to be set, setting condition, and check timing.

Buffer

Setting item Setting

range Default value Setting

Check timing of

memory

condition

the set data

address

(decimal)

Pr.3

PLC READY

signal (Y2D) is turned

must be off.

Pr.4

Show 13 more labels / short text on this page
4Mpulse/s · Numerator of · command pulse · multiplication for · When PLC READY · electronic gear (CMX) · 1 to 9999 · signal (Y2D) · Denominator of · on · command pulse · multiplication for · electronic gear (CDV)
Page 213 of the Mitsubishi Electronics QD73A1 user manual — (2) Precautions for control
Page 213 · click to enlarge
Page 213

CHAPTER 11 CONTROL SUB FUNCTIONS

11.2 Speed Limit Function

The "speed limit function" limits command speed to the value set in " Speed limit value" when command speed

Pr.5

during major positioning control or JOG operation exceeds " Speed limit value".

Pr.5

(1) Control detail

This function is active on major positioning control and JOG operation.

When the value set in " Speed limit value" is exceeded in each control, command speed is limited to

Pr.5

" Speed limit value".

Pr.5

The operation of the speed limit function is as follows.

Positioning speed V1 Da.3

Speed limit value Pr.5

In the figure above, the speed set in " Speed limit value" is output since " Positioning speed V1" is

Pr.5 Da.3

faster than " Speed limit value". In this case, the movement amount that was not output because of the

Pr.5

speed limit (1 in the figure) is output later (2 in the figure), delaying the positioning completion.

11.2 Speed Limit Function

(2) Precautions for control

Set positioning speed and JOG speed to a value equal to or less than " Speed limit value". If " Speed

Pr.5 Pr.5

limit value" is exceeded, command speed is limited to " Speed limit value".

Pr.5

Also, set OPR speed to a value equal to or less than " Speed limit value". If " Speed limit value" is

Pr.5 Pr.5

exceeded, the error "OPR speed Outside the setting range" (error code: 20) occurs at the start of OPR.

t

Page 214 of the Mitsubishi Electronics QD73A1 user manual — Buffer
Page 214 · click to enlarge
Page 214

(3) Setting the speed limit function

The following table lists the data to be set, setting condition, and check timing.

Buffer

Setting item Setting range Default value Setting condition Check timing of the

memory

set data

address

(decimal)

The data can be set

anytime.

  • When a positioning start

signal (Y21 to Y23) is

the rise (ON) of a start

signal is used for the

  • When a JOG start

operation. If the data is

21 Pr.5

(Set in the unit of

signal (Y24, Y25) is

10pulse/s.)

signal (X14) is on, the

  • When OPR start signal

data will be accepted at

(Y20) is turned on

the rise (ON) of the next

start signal.

Set " Speed limit value" in a unit of 10 pulses. If a single digit is set, the value is rounded off.

Pr.5

Ex.

For instance, if "1999" is set, the operation is executed with a speed limit value of "1990".

Show 8 more labels / short text on this page
10 to · turned on · Speed limit · 4000000pulse/s · 200000 pulse/s · value · written when BUSY · turned on
Page 215 of the Mitsubishi Electronics QD73A1 user manual — (1) Control detail
Page 215 · click to enlarge
Page 215

CHAPTER 11 CONTROL SUB FUNCTIONS

11.3 Stroke Limit Function

The "stroke limit function" controls operation not to execute positioning when a command that moves the workpiece

outside the specified stroke limit range is given.

(1) Control detail

This function limits the moving range of the workpiece.

The following figure shows a moving range of a workpiece when the stroke limit function is used.

Mitsubishi Electronics QD73A1 — (1) Control detail diagram (page 215)
Fig. 110 · (1) Control detail

The following is an example in which a moving range of a workpiece changes following a current value change.

Mitsubishi Electronics QD73A1 — (1) Control detail diagram (page 215)
Fig. 111 · (1) Control detail

Ex. When the current stop position is 2000 and the stroke limit upper limit is set to 5000

As the current value is changed from 2000 to 1000, " Current feed value" changes to 1000,

Page 216 of the Mitsubishi Electronics QD73A1 user manual — (5) Disabling the stroke limit function
Page 216 · click to enlarge
Page 216

(2) Stroke limit check details and processing for each control

The following table describes stroke limit checks and processing in case of an error that are performed by the

QD73A1.

Check number Check detail Processing in case of an error

If a current value is outside the stroke limit range*1, the

The module turns on Error detection signal

module reports an error. (The module checks

(X18), and reports the error "Outside the

" Current feed value".)

stroke limit range at start" (error code: 83).

Md.1

If a positioning address setting is outside the stroke limit

The module turns on Error detection signal

range*1, the module reports an error. (The module checks

(X18), and reports the error "Positioning

address Outside the setting range" (error

" Positioning address P1".)

Da.2

code: 30).

If a current value exceeds the stroke limit range*1, the

The module turns on Error detection signal

module reports an error. (The module checks

(X18), and reports the error "Outside the

stroke limit range" (error code: 100).

" Current feed value".)

Md.1

*1 The range from " Stroke limit upper limit" to " Stroke limit lower limit"

Pr.1 Pr.2

The following table describes the corresponding stroke limit check for each control.

Control Stroke limit check

OPR control Stroke limit check 3 is performed.

Stroke limit check 1 and 2 are performed. Two-phase trapezoidal

Speed-position control switch mode

JOG operation Stroke limit check 3 is performed.

Current value change No stroke limit check is performed.

(3) Precaution for control

To execute the stroke limit function normally, OPR must be executed beforehand.

(4) Setting the stroke limit function

The following table lists the data to be set, setting condition, and check timing.

Buffer

Setting item Setting range Default value Setting

Check timing

memory

condition

of the set data

address

(decimal)

Stroke limit upper limit

Pr.1

pulse PLC READY signal

(Y2D) must be off.

Stroke limit lower limit 0pulse 2

Pr.2

(5) Disabling the stroke limit function

Set values as follows.

Pr.1 Pr.2

Stroke limit upper limit = Stroke limit lower limit

Show 15 more labels / short text on this page
Position · Positioning control · Major · control · positioning · mode · positioning control · control · 2147483647 · When PLC · -2147483648 to · READY signal · 2147483647 pulse · (Y2D) is turned · on
Page 217 of the Mitsubishi Electronics QD73A1 user manual — QD73A1
Page 217 · click to enlarge
Page 217

CHAPTER 11 CONTROL SUB FUNCTIONS

11.4 Upper Limit Switch (FLS)/Lower Limit Switch (RLS) Function

The "upper limit switch (FLS)/lower limit switch (RLS) function" decelerates and stops operation according to signal

inputs from limit switches that are placed at the upper and lower limits of the machine's movable range.

This function prevents the machine from being damaged by stopping the operation before the workpiece reaches the

upper or lower limit of the moving range, which is a physical limit that the QD73A1 can handle.

Normally, upper limit switch (FLS) and lower limit switch (RLS) are placed inside the stroke limits (stroke ends) of the

drive unit, so that the operation is stopped before the workpiece reaches a stroke limit (stroke end) of the drive unit.

(1) Control detail

The following figure shows the operation of the upper limit switch (FLS)/lower limit switch (RLS) function.

Lower limit Upper limit

Decelerates and stops upon detection of the lower limit switch (RLS)

Decelerates and stops upon detection of the upper limit switch (FLS)

Control range of the QD73A1

Mechanical stopper Mechanical stopper

Starts toward the lower limit direction

Starts toward the upper limit direction

QD73A1

Upper limit switch (FLS) Stroke limit of the drive unit

Lower limit switch (RLS)

Stroke limit of the drive unit

11.4 Upper Limit Switch (FLS)/Lower Limit Switch (RLS) Function

Moving direction · Moving direction · Drive unit

Page 218 of the Mitsubishi Electronics QD73A1 user manual — QD73A1
Page 218 · click to enlarge
Page 218

(2) Wiring upper limit switch (FLS) and lower limit switch (RLS)

To use the upper limit switch (FLS)/lower limit switch (RLS) function, wire the QD73A1's terminals for Upper limit

signal (FLS) and Lower limit signal (RLS) as in the following figure.

QD73A1

FLS

RLS

COM

24VDC

When wiring the terminals, set the switch that is placed on the direction in which " Current feed value"

Md.1

increases as an upper limit switch (FLS), and the switch that is placed on the direction in which " Current

Md.1

feed value" decreases as a lower limit switch (RLS).

If the upper and lower limit switches are wired opposite, the upper limit switch (FLS)/lower limit switch (RLS)

function does not operate normally, and the motor does not stop.

(3) Precautions for control

  • OPR control, major positioning control, and JOG operation cannot be started from the area where the upper

limit switch (FLS) had detected overrange in the direction where " Current feed value" increases. Also,

Md.1

OPR control, major positioning control, and JOG operation cannot be started from the area where the lower

limit switch (RLS) had detected overrange in the direction where " Current feed value" decreases. To

Md.1

start operation again, move the workpiece to a position within the control range of the QD73A1 using JOG

operation.

  • If the wiring between Upper limit signal (FLS) and COM terminal or between Lower limit signal (RLS) and

COM terminal is open (including the case that the terminals are not wired), the QD73A1 cannot execute

positioning.

(4) When the upper limit switch (FLS)/lower limit switch (RLS) function is not used

Wire the QD73A1's terminals for Upper limit signal (FLS) and Lower limit signal (RLS) as in the following figure.

QD73A1

FLS

RLS

COM

24VDC

Page 219 of the Mitsubishi Electronics QD73A1 user manual — Execution condition of
Page 219 · click to enlarge
Page 219

CHAPTER 11 CONTROL SUB FUNCTIONS

11.5 Current Value Change Function

The "current value change function" changes the value set in " Current feed value" to a specified value.

Md.1

Use this function when operation cannot be started due to a current feed value outside the stroke range, or to change

the current value.

(1) Control detail

As a new address is set in " New current value" and "1" is written in " Current value change request",

Cd.1 Cd.7

" Current feed value" changes to the value set in " New current value".

Md.1 Cd.1

" Actual current value" is equal to " Current feed value - Accumulated pulses in the deviation

Md.2 Md.1

counter". When the accumulated pulse amount in the deviation counter is 0, " Current feed value" is equal

Md.1

to " Actual current value".

Md.2

Md.1

Md.2

Md.1 Current feed value - Accumulated pulses in the deviation counter

(2) Precautions for control

  • If "1" is set in " Current value change request" when BUSY signal (X14) is on, the error "Current value

Cd.7

change error" (error code: 110) occurs and the current value is not changed.

11.5 Current Value Change Function

  • If the current value is changed to a value outside the stroke limit range, an error does not occur.

(3) Data setting and the execution condition of the function

The following table lists the data to be set and the condition to execute the current value change function.

Execution condition of

Buffer memory

Setting item Setting range Default value

the current value change

address

function

(decimal)

Cd.1

2147483647pulse 0pulse BUSY signal (X14) must be

1. Change the current

off.

Cd.7

Show 8 more labels / short text on this page
Current feed value · Actual current value · New current · -2147483648 to · value · Current value · value 0 90 · change request
Page 220 of the Mitsubishi Electronics QD73A1 user manual — Y25)
Page 220 · click to enlarge
Page 220

11.6 Speed Change Function

The "speed change function" changes the speed of the operation in process to a specified speed at a specified timing.

Set a new speed value to the buffer memory and request the speed change.

(1) Control detail

The following figure shows the operation of speed changes.

Speed change to V2 Positioning in V1

Speed change to V3

(2) Precautions for control

(a) Speed change during two-phase trapezoidal positioning control

  • A speed change requested during two-phase trapezoidal positioning control is reflected to the command

speed ( , ) of the next positioning data.

Da.3 Da.5

Positioning control P1 Next control P2

Cd.2

Command speed of P2

Command speed of P1

  • If the remaining distance is not enough to change speed, the speed cannot be changed during two-phase

trapezoidal positioning control.

(b) Timing at which speed cannot be changed

Speed cannot be changed at the following timings.

  • During deceleration following a stop command
  • During OPR

(The error "Speed change error (OPR)" (error code: 111) occurs.)

  • During automatic deceleration in major positioning control

(The error "Speed change error (Positioning)" (error code: 112) occurs.)

  • During deceleration stop of JOG operation following a change (from on to off) of a JOG start signal (Y24,

Y25)

(The error "Speed change error (JOG)" (error code: 113) occurs.)

t · New speed value · Speed change command

Page 221 of the Mitsubishi Electronics QD73A1 user manual — Buffer
Page 221 · click to enlarge
Page 221

CHAPTER 11 CONTROL SUB FUNCTIONS

(c) New speed and " Speed limit value"

Pr.5

When the value set in " New speed value" exceeds " Speed limit value", the positioning is operated

Cd.2 Pr.5

at " Speed limit value".

Pr.5

(d) Successive speed changes

To change speed successively, set an interval of 10ms or more between each speed change. If there are not

enough intervals between speed changes, the QD73A1 may not be able to follow the requests and process the

commands normally.

(e) When "0" is set in " New speed value"

Cd.2

When "0" is set in " New speed value" and a speed change is requested, the axis stops. Though, BUSY

Cd.2

signal (X14) stays on. (Inputting Stop signal turns off BUSY signal (X14).)

To activate the axis again, set a value other than "0" in " New speed value" and request the speed

Cd.2

change.

ON

Positioning start signal (Y21 to Y23)

OFF

ON

OFF

Cd.2 New speed value 1000

11.6 Speed Change Function

ON

Cd.8 Speed change request

OFF

Executed by the QD73A1

(3) Data setting and the execution condition of the function

The following table lists the data to be set and the condition to execute the speed change function.

Buffer

Setting item Setting range Default value Execution condition of the speed

memory

change function

address

(decimal)

0 to " Speed limit

BUSY signal (X14) must be on. Note that

Pr.5

speed cannot be changed at the following.

Cd.2

  • After the start of automatic deceleration
  • After the input of Stop signal (Y27) or Stop
  • After a JOG start signal (Y24, Y25) was
1. Change speed 0 91

Cd.8

turned off during JOG operation

  • During OPR
Show 13 more labels / short text on this page
Positioning operation · t · BUSY signal (X14) · New speed · value" (pulse/s) · 0pulse/s · value · (Maximum 4000000 · pulse/s) · signal (STOP) · Speed · change · request
Page 222 of the Mitsubishi Electronics QD73A1 user manual — Execution condition of
Page 222 · click to enlarge
Page 222

11.7 Deviation Counter Clear Function

The "deviation counter clear function" clears the accumulated pulses in the deviation counter to 0.

When the servomotor power was turned off due to an emergency stop during positioning, clearing the accumulated

pulses in the deviation counter to 0 prevents servomotor rotation at power recovery.

(1) Precautions for control

(a) Start after clearing deviation counter

To start positioning after clearing the deviation counter, check the following two points.

  • The value in " Deviation counter clear command" changed to 0.

Cd.4

  • No error is occurring.

(b) " Actual current value" and " Current feed value"

Md.2 Md.1

  • When the deviation counter is cleared, " Actual current value" changes to the value in

Md.2

" Current feed value".

Md.1

  • To change " Current feed value" of after clearing the deviation counter to " Actual current

Md.1 Md.2

value" of before clearing the deviation counter, follow the procedure below.

1 Read out the value in " Actual current value".

Md.2

2 Write the read value to " New current value".

Cd.1

3 Clear the deviation counter.

4 Change the current value.

(2) Data setting and the execution condition of the function

The following table lists the data to be set and the condition to execute the deviation counter clear function.

Execution condition of

Buffer memory

Setting item Setting range Default value

the deviation counter

address

clear function

(decimal)

1. Clear the deviation

counter 0 BUSY signal (X14) must be

Cd.4

off. 86

Deviation counter clear · command

Page 223 of the Mitsubishi Electronics QD73A1 user manual — (b) Timing at which In-position signal (X16) turns off
Page 223 · click to enlarge
Page 223

CHAPTER 11 CONTROL SUB FUNCTIONS

11.8 In-position Function

The "in-position function" turns on In-position signal (X16) while the accumulated pulse amount in the deviation

counter is within the specified in-position range (1 to 20479pulse) after deceleration started.

In-position signal (X16) can be used as the signal right before positioning completion.

(1) Control detail

In-position signal (X16) turns on when the accumulated pulse amount in the deviation counter becomes equal to

the value set in " In-position range" and stays on till the next start.

Pr.8

Pulse output Motor speed

ON

OFF

Turns on when the deviation counter value (pulse) becomes the one within the set in-position range. Turns off at start.

Accumulated pulse amount is checked with the in-position range every 0.5ms.

11.8 In-position Function

(2) Precautions for control

(a) During speed control in the speed-position control switch mode

Accumulated pulse amount is not checked with the in-position range.

(b) Timing at which In-position signal (X16) turns off

In-position signal (X16) turns off at the following timings.

  • When OPR starts
  • When positioning control starts
  • When two-phase trapezoidal positioning control starts
  • When the speed-position control switch mode starts
  • When JOG operation starts
Show 4 more labels / short text on this page
Accumulated pulses · t · In-position setting range · In-position signal (X16)
Page 224 of the Mitsubishi Electronics QD73A1 user manual — Buffer
Page 224 · click to enlarge
Page 224

(3) Setting the in-position function

The following table lists the data to be set, setting condition, and check timing.

Buffer

Setting item Setting

Default

value Setting condition Check timing of

memory

range

the set data

address

(decimal)

  • When a positioning

The data can be set anytime.

start signal (Y21 to

Y23) is turned on

(ON) of a start signal is used for

  • When a JOG start

the operation. If the data is

24 Pr.8

signal (Y24, Y25) is

written when BUSY signal

(X14) is on, the data will be

  • When OPR start

accepted at the rise (ON) of the

next start signal.

Show 7 more labels / short text on this page
In-position · 1 to · 20479pulse 5pulse · range · turned on · signal (Y20) is · turned on
Page 225 of the Mitsubishi Electronics QD73A1 user manual — OFF
Page 225 · click to enlarge
Page 225

CHAPTER 11 CONTROL SUB FUNCTIONS

11.9 Accumulated Pulse Error Detection Function

The accumulated pulse error detection function outputs an alert and immediately stops the positioning when the

accumulated pulses reached the amount specified by the user before the pulses exceed the amount set in

"Accumulated pulse setting" in the switch setting and an excessive error occurs.

This function enables to detect abnormal operating status in early stages and minimize the influence on the

mechanical system.

(1) Control details

The following figures show the operation of the accumulated pulse error detection function.

An alert occurs because the accumulated pulses have exceeded the amount of Alert output accumulated pulses (maximum value).

Positioning stops immediately because the accumulated pulses have exceeded the amount of Immediate stop accumulated pulses (maximum value). (Accumulated pulse clear)

Immediate stop accumulated pulses (maximum value)

Alert output accumulated pulses (maximum value)

Reference value (maximum value)

The accumulated pulses increase because the workpiece hit something and stopped.

11.9 Accumulated Pulse Error Detection Function

ON

Cd.18

Accumulated pulse error detection request

OFF

ON

Start signal (Y20 to Y26)

OFF

ON

OFF

ON

Excessive error signal (X17)

OFF

ON

Error detection signal (X18) OFF

ON

Servo ON signal (SVON)

OFF

Error code (ERR.1) Md.3

Md.21

Deviation counter value (pulse)

Executed by the QD73A1

Show 5 more labels / short text on this page
Accumulated · pulse · t · BUSY signal (X14) · Inconsistent 0
Page 226 of the Mitsubishi Electronics QD73A1 user manual — (2) Executing procedure
Page 226 · click to enlarge
Page 226

(a) Alert output

The QD73A1 compares accumulated pulses that are output during the positioning with alert output

accumulated pulses. If accumulated pulses exceed the amount of the alert output accumulated pulses, the

error "Accumulated pulse alert" (error code: 130) occurs. (Even after the error occurs, the positioning

continues.)

(b) Immediate stop processing

The QD73A1 compares accumulated pulses that are output during the positioning with immediate stop

accumulated pulses. If accumulated pulses exceed the amount of the immediate stop accumulated pulses, the

QD73A1 performs the following processing and stops the positioning.

  • Excessive error signal (X17): ON
  • Accumulated pulse: Clear to 0
  • Servo ON signal (SVON): OFF
  • BUSY signal (X14): OFF (Positioning complete signal (X15) does not turn on.)

Turn on PLC READY signal (Y2D) to restore the positioning (In the same way as when an excessive error

occurs).

(2) Executing procedure

The following is the executing procedure of the accumulated pulse error detection function.

Measure the reference value.

Page 225, Section 11.9.1

Save the measured reference value in the flash ROM inside the QD73A1.

Page 225, Section 11.9.1

Set the data to use the accumulated pulse error detection function.

Page 226, Section 11.9.2

Execute the positioning.

Start · End

Page 227 of the Mitsubishi Electronics QD73A1 user manual — OFF
Page 227 · click to enlarge
Page 227

CHAPTER 11 CONTROL SUB FUNCTIONS

11.9.1 Measuring and saving the reference value in the flash ROM

Before using the accumulated pulse error detection function, the reference value needs to be measured to detect

errors.

Reference value means the maximum/minimum accumulated pulse values that are output when the QD73A1 is

operating normally.

The QD73A1 obtains the judgment value for alert output and immediate stop and carry out control using the reference

value, alert output accumulated pulse setting value, and immediate stop accumulated pulse setting value.

Executing procedure is as follows.

1. Set " Measurement start request" to "1: Requested" and start the reference value

Cd.19

measurement. The QD73A1 monitors the status of accumulated pulses and measures the maximum/minimum values

while " Measurement start request" is set to 1. 2. Set " Reference value write request" to "1: Requested" when " Reference value

Cd.19

Cd.20 Md.20

measurement flag" is set to "1: Measured".

The QD73A1 saves the measured maximum/minimum values in the flash ROM when " Reference value write request" is set to 1.

Cd.20

11.9 Accumulated Pulse Error Detection Function 11.9.1 Measuring and saving the reference value in the flash ROM

ON

Start signal (Y20 to Y26)

OFF

ON

OFF

ON

Cd.19

OFF

ON

Md.20

Reference value measurement flag

OFF

ON

Cd.20

OFF

Cleared to 0 by the QD73A1

Executed by the QD73A1

Show 11 more labels / short text on this page
Measurement range · Positioning command · t · Maximum value · Accumulated pulse · Minimum value · BUSY signal (X14) · Measurement start · request · Reference value · write request
Page 228 of the Mitsubishi Electronics QD73A1 user manual — Buffer
Page 228 · click to enlarge
Page 228

11.9.2 Setting the accumulated pulse error detection function

Set the values of " Alert output accumulated pulse setting value (maximum value)" to " Immediate stop

Cd.13 Cd.16

accumulated pulse setting value (minimum value)", and set " Accumulated pulse error detection request" to 1 to

Cd.18

execute the accumulated pulse error detection function. Set the data required for control in the sequence program.

The following table lists the data to be set, setting condition, and check timing.

Buffer

Setting item Setting range Default

value Setting condition Check timing of

memory

the set data

address

(decimal)

  • If " Accumulated pulse

Cd.17

setting value selection" is set

Cd.13

to 0:

1 to 148000 pulse

  • If " Accumulated pulse

Cd.17

setting value selection" is set

to 1:

Cd.14

(× 10-3)

The data can be set

  • If " Accumulated pulse

Cd.17

anytime.

setting value selection" is set

Cd.18

Cd.15

to 0:

-148000 to -1 pulse

from 0 to 1.)

  • If " Accumulated pulse

Cd.17

setting value selection" is set

to 1:

Cd.16

(× 10-3)

0. Set with pulse
0. Set

Cd.17

1. Set with magnification
0. No request
0. No

Cd.19

Cd.18

1. Requested

start request" must be

set to 0.

Cd.18

0. No request
0. No

Cd.19

1. Requested

request" must be set

to 0.

0. No request
0. No

Md.20

Cd.20

1. Requested

flag" must be set to 1.

*1 Set both alert output accumulated pulse setting value and immediate stop accumulated pulse setting value. If either of the values is set to 0, the accumulated pulse error detection function does not operate. The error "Accumulated pulse error undetectable" (error code: 131) occurs. *2 If either of the maximum value and minimum value is set properly, the accumulated pulse error detection function operates. The error detection is not executed for the unset side. *3 Each request is detected on a cycle of 0.5ms.

Show 48 more labels / short text on this page
Alert output · accumulated pulse · setting value · (maximum · value)*1*2 · Immediate stop · accumulated pulse · setting value · 1000 to 50000 · (maximum · When accumulated · value)*1*2 · pulse error detection · is requested · Alert output · (When · accumulated pulse · " Accumulated · setting value · pulse error detection · (minimum · request" is changed · value)*1*2 · Immediate stop · accumulated pulse · setting value · 1000 to 50000 · (minimum · value)*1*2 · Accumulated pulse · setting value · with pulse 408 · selection · Accumulated pulse · " Measurement · error detection · request · request*3 · " Accumulated · Measurement start · pulse error detection · request*3 · request · " Reference · Reference value · value measurement · write request*3 · request
Page 229 of the Mitsubishi Electronics QD73A1 user manual — (b) Alert output accumulated pulse setting value and immediate stop accumulated
Page 229 · click to enlarge
Page 229

CHAPTER 11 CONTROL SUB FUNCTIONS

(1) Alert output accumulated pulses and immediate stop accumulated pulses

Alert output accumulated pulses (accumulated pulses set to output an alert) and immediate stop accumulated

pulses (accumulated pulses set to stop the positioning immediately) are set by combining the following values.

  • Reference value
  • Alert output accumulated pulse setting value ( , )

Cd.13 Cd.15

  • Immediate stop accumulated pulse setting value ( , )

Cd.14 Cd.16

  • Accumulated pulse setting value selection

Cd.17

(2) If " Accumulated pulse setting value selection" is set to "0: Set with pulse"

Cd.17

Alert output accumulated pulses and immediate stop accumulated pulses can be obtained as follows:

Alert output accumulated pulses = reference value + alert output accumulated pulse setting value

Immediate stop accumulated pulses = reference value + immediate stop accumulated pulse setting value

(a) When the value is outside the setting range

The accumulated pulse error detection function does not operate.

(b) Alert output accumulated pulse setting value and immediate stop accumulated

pulse setting value

The value of alert output accumulated pulses (maximum value) is calculated using the value of

" Immediate stop accumulated pulse setting value (maximum value)" at the following condition:

Cd.14

" Alert output accumulated pulse setting value (maximum value)" > " Immediate stop accumulated

Cd.13 Cd.14

pulse setting value (maximum value)"

11.9 Accumulated Pulse Error Detection Function 11.9.2 Setting the accumulated pulse error detection function

The value of alert output accumulated pulses (minimum value) is calculated using the value of

" Immediate stop accumulated pulse setting value (minimum value)" at the following condition:

Cd.16

" Alert output accumulated pulse setting value (minimum value)" < " Immediate stop accumulated

Cd.15 Cd.16

pulse setting value (minimum value)"

Ex. When the setting values are as follows:

  • Alert output accumulated pulse setting value (maximum value): 1200

Cd.13

  • Immediate stop accumulated pulse setting value (maximum value): 1100

Cd.14

Both alert output accumulated pulses and immediate stop accumulated pulses are judged by the

reference value + 1100 pulse. Thus, an alert is output and the positioning stops simultaneously.

Page 230 of the Mitsubishi Electronics QD73A1 user manual — (b) Alert output accumulated pulse setting value and immediate stop accumulated
Page 230 · click to enlarge
Page 230

(c) Alert output accumulated pulse setting value, immediate stop accumulated pulse

setting value, and "Accumulated pulse setting" in the switch setting

The setting range of " Alert output accumulated pulse setting value (maximum value)" is 1 to 148000 (the

Cd.13

range of " Alert output accumulated pulse setting value (minimum value)" is -148000 to -1). However,

Cd.15

when the alert output accumulated pulses exceed the amount of "Accumulated pulse setting" in the switch

setting, an alert is output according to the setting of "Accumulated pulse setting".

The above is applicable to " Immediate stop accumulated pulse setting value (maximum value)" and

Cd.14

" Immediate stop accumulated pulse setting value (minimum value)".

Cd.16

Ex. When the measured reference value (maximum value) is 2000 and the setting values are as follows:

  • "Accumulated pulse setting" in the switch setting: -3700 to 3700 [selection 1]
  • Alert output accumulated pulse setting value (maximum value): 3000

Cd.13

The calculated value of alert output accumulated pulses (maximum value) is 5000 (2000 + 3000).

However, the value of alert output accumulated pulses (maximum value) becomes 3700 because the

calculated value exceeds the amount of "Accumulated pulse setting"

(3) If " Accumulated pulse setting value selection" is set to "1: Set with magnification"

Cd.17

Alert output accumulated pulses and immediate stop accumulated pulses can be obtained as follows:

Alert output accumulated pulses = reference value + (Alert output accumulated pulse setting value - 1000) ×

Immediate stop accumulated pulses = reference value + (immediate stop accumulated pulse setting value -

1000) × reference value 1000

Last three digits of the setting value indicate the value after the decimal point.

Ex. When the alert output accumulated pulse setting value is 1234, the alert output accumulated pulses can

be obtained by multiplying the reference value by 1.234.

(a) When the value is outside the setting range

The accumulated pulse error detection function does not operate.

(b) Alert output accumulated pulse setting value and immediate stop accumulated

pulse setting value

The value of alert output accumulated pulses (maximum value) is calculated using the value of

" Immediate stop accumulated pulse setting value (maximum value)" at the following condition:

Cd.14

" Alert output accumulated pulse setting value (maximum value)" > " Immediate stop accumulated

Cd.13 Cd.14

pulse setting value (maximum value)"

The value of alert output accumulated pulses (minimum value) is calculated using the value of

" Immediate stop accumulated pulse setting value (minimum value)" at the following condition:

Cd.16

" Alert output accumulated pulse setting value (minimum value)" > " Immediate stop accumulated

Cd.15 Cd.16

pulse setting value (minimum value)"

reference value 1000

Page 231 of the Mitsubishi Electronics QD73A1 user manual — (c) Alert output accumulated pulse setting value, immediate stop accumulated pulse
Page 231 · click to enlarge
Page 231

CHAPTER 11 CONTROL SUB FUNCTIONS

Ex. When the setting values are as follows:

  • Alert output accumulated pulse setting value (maximum value): 1200

Cd.13

  • Immediate stop accumulated pulse setting value (maximum value): 1100

Cd.14

Both alert output accumulated pulses and immediate stop accumulated pulses are judged by

accumulated pulses that are 1.1 times of the reference value (maximum value). Thus, an alert is output

and the positioning stops simultaneously.

(c) Alert output accumulated pulse setting value, immediate stop accumulated pulse

setting value, and "Accumulated pulse setting" in the switch setting

The setting range of " Alert output accumulated pulse setting value (maximum value)" and " Alert

Cd.13 Cd.15

output accumulated pulse setting value (minimum value)" is 1000 to 50000 (1 to 50 times). However, when the

alert output accumulated pulses exceed the amount of "Accumulated pulse setting" in the switch setting, an

alert is output according to the setting of "Accumulated pulse setting"

The above is applicable to " Immediate stop accumulated pulse setting value (maximum value)" and

Cd.14

" Immediate stop accumulated pulse setting value (minimum value)".

Cd.16

Ex. When the measured reference value (maximum value) is 2000 and the setting values are as follows:

  • "Accumulated pulse setting" in the switch setting: -3700 to 3700 [selection 1]
  • Alert output accumulated pulse setting value (maximum value): 3000 (3 times)

Cd.13

The calculated value of alert output accumulated pulses (maximum value) is 6000 (2000 + (3000 - 1000)

× 2000 1000). However, the value of alert output accumulated pulses (maximum value) becomes 3700

because the calculated value exceeds the amount of "Accumulated pulse setting"

11.9 Accumulated Pulse Error Detection Function 11.9.2 Setting the accumulated pulse error detection function

Page 232 of the Mitsubishi Electronics QD73A1 user manual — ON *3
Page 232 · click to enlarge
Page 232

CHAPTER 12 STOPPING AND RESTARTING

CONTROL

This chapter describes stops and restarts of control.

12.1 Stopping Control

This section describes control stops.

The QD73A1 stops control in case of the following.

  • When each control ended normally
  • When Servo READY signal (READY) turned off
  • When an error occurred in the CPU module
  • When PLC READY signal (Y2D) was turned off
  • When an error occurred in the QD73A1
  • When control was stopped intentionally (turning on Stop signal (Y27) or inputting Stop signal (STOP))
  • When the upper limit switch (FLS) or the lower limit switch (RLS) turned off
  • When the power supply was turned off

(1) Cause of a stop and process of stopping

The following table describes causes of stops and the subsequent processing (except the stop in case of normal

completion of positioning).

Status of Error

Error Process of

Cause of stop

detection

stop

signal (X18)

(READY) turned off.*1 ON Servo READY OFF while BUSY (error code: 90)

Free run The power supply was

turned off.

The upper limit switch

Upper limit signal OFF while BUSY (error code: 91)

(FLS) turned off.

ON

The lower limit switch

(RLS) turned off. Lower limit signal OFF while BUSY (error code: 92)

PLC READY signal OFF during operation (error code: 105)*2

(Y2D) was turned off. ON

PLC READY signal OFF during OPR (error code: 103)*3

External stop signal ON during OPR (error code: 93)*3

was input.

ON *3

Stop signal (Y27) was

turned on. STOP signal ON during OPR (error code: 102)*3

*1 The operation varies as shown below depending on "Deviation counter clear setting" in the switch setting. If "0: Clear the deviation counter when the servo ready signal is OFF." is set, the analog output voltage becomes the value on which zero adjustment was made at the timing when Servo READY signal (READY) has turned off. If "1: Do not clear the deviation counter when the servo ready signal is OFF." is set, the analog output voltage equivalent to the accumulated pulses in the deviation counter is output. *2 Only during major positioning control or JOG operation *3 Only during OPR

Show 11 more labels / short text on this page
Servo READY signal · Forced stop · Fatal stop · Emergency · PLC READY signal · Deceleration · stop · stop · Stop signal (STOP) · Intentional · stop
Page 233 of the Mitsubishi Electronics QD73A1 user manual — (X13)
Page 233 · click to enlarge
Page 233

CHAPTER 12 STOPPING AND RESTARTING CONTROL

An emergency stop circuit should be built outside the programmable controller.

(2) Stop during OPR

If an error (a cause of a stop) occurs during OPR, a deceleration stop starts at the error occurrence.

At the completion of the deceleration stop, OPR request signal (X12) stays on. Also, OPR complete signal (X13)

does not turn on since the OPR was not completed normally.

The following figure is the timing chart of when Stop signal (Y27) is turned on during OPR.

ON

(Y20)

OFF

ON

(X14)

OFF

ON

(X12)

OFF

12.1 Stopping Control

(X13)

OFF

ON

(Y27)

OFF

ON

(X18)

OFF

Error code (ERR.1) Md.3 102 (STOP signal ON during OPR)

Executed by the QD73A1

Show 10 more labels / short text on this page
Deceleration start · t · Near-point dog · Zero signal · OPR start signal · BUSY signal · OPR request signal · OPR complete signal · Stop signal · Error detection signal
Page 234 of the Mitsubishi Electronics QD73A1 user manual — OFF
Page 234 · click to enlarge
Page 234

(3) Stop during major positioning control or JOG operation

(a) Stop before deceleration start of major positioning control or JOG operation

If an error (a cause of a stop) occurs prior to a start of deceleration during major positioning control or JOG

operation, a deceleration stop starts at the error occurrence. The deceleration speed depends on

" Deceleration time" and " Speed limit value".

Pr.7 Pr.5

Positioning complete signal (X15) does not turn on at the completion of the deceleration stop.

Also, the next positioning does not start even if the error is resolved while the start signal is on. The start signal

must be turned off and on.

The following figure is the timing chart of when Stop signal (Y27) is turned on during positioning control.

ON

OFF

ON

Does not start even if Stop signal (Y27) is turned off

OFF

(X14)

OFF

(X15)

ON

(Y27)

OFF

OFF

(X18) *1

Executed by the QD73A1

*1 Error detection signal (X18) does not turn on in case of a stop following a change (from off to on) of Stop signal (Y27) or an input of Stop signal (STOP). Error detection signal (X18) turns on due to the following.

  • Servo READY signal (READY) turned off.
  • PLC READY signal (Y2D) was turned off.
  • Upper limit signal (FLS) turned off.
  • Lower limit signal (RLS) turned off.
Show 8 more labels / short text on this page
Deceleration start · t · Positioning start signal · (Y21 to Y23) · BUSY signal · Positioning complete signal · Stop signal · Error detection signal
Page 235 of the Mitsubishi Electronics QD73A1 user manual — ON
Page 235 · click to enlarge
Page 235

CHAPTER 12 STOPPING AND RESTARTING CONTROL

(b) Stop during deceleration of major positioning control or JOG operation

If an error (a cause of a stop) occurs during deceleration of major positioning control or JOG operation, the

deceleration continues and the operation stops since it is toward completion of the positioning or is following a

change (from on to off) of a JOG start signal (Y24, Y25). In case of major positioning control, Positioning

complete signal (X15) turns on at its completion.

This process is the same for a stop with an error.

The following figure is the timing chart of when Stop signal (Y27) is turned on during deceleration of positioning

control.

ON

OFF

ON

(X14)

OFF

ON

(X15)

OFF

ON

OFF

(Y27)

(X18) *1

OFF

Executed by the QD73A1

*1 Error detection signal (X18) does not turn on in case of a stop following a change (from off to on) of Stop signal (Y27) or an input of Stop signal (STOP). Error detection signal (X18) turns on due to the following.

12.1 Stopping Control

  • Servo READY signal (READY) turned off.
  • PLC READY signal (Y2D) was turned off.
  • Upper limit signal (FLS) turned off.
  • Lower limit signal (RLS) turned off.
Show 7 more labels / short text on this page
t · Positioning start signal · (Y21 to Y23) · BUSY signal · Positioning complete signal · Stop signal · Error detection signal
Page 236 of the Mitsubishi Electronics QD73A1 user manual — (1) Control detail
Page 236 · click to enlarge
Page 236

12.2 Restarting the Speed-position Control Switch Mode

After a deceleration stop following Stop signal, the operation of the speed-position control switch mode before the stop

can be restarted by turning on Speed-position mode restart signal (Y26).

(1) Control detail

(a) When positioning is stopped using Stop signal (Y27) or Stop signal (STOP)

The positioning before the stop can be restarted by turning on Speed-position mode restart signal (Y26).

The following figure shows the timing at which the speed-position control switch mode restarts.

Mitsubishi Electronics QD73A1 — (1) Control detail diagram (page 236)
Fig. 112 · (1) Control detail

Turning on Stop signal (Y27) starts deceleration. Turning on Stop signal (Y27) starts deceleration.

Page 237 of the Mitsubishi Electronics QD73A1 user manual — (Y21) × ×
Page 237 · click to enlarge
Page 237

CHAPTER 12 STOPPING AND RESTARTING CONTROL

(b) When speed is changed during positioning

After a stop following the input of Stop signal (STOP), if Speed-position mode restart signal (Y26) is turned on,

the positioning restarts according to the positioning speed set in the positioning data. The positioning does not

restart at the new speed.

Speed control Position control Position control

Speed-position switching command signal (CHANGE)

(c) Precautions for control

  • The following table indicates settings and start signal conditions to restart control. If Speed-position mode

restart signal (Y26) is turned on in a condition "Restart possible", the error "Restart error" (error code: 85)

occurs.

: Restart possible

×: Restart not possible

" Positioning mode"

Pr.9

Start signal

0: Position control mode 1: Speed-position control switch

mode

OPR start signal (Y20) × ×

Absolute positioning start signal

12.2 Restarting the Speed-position Control Switch Mode

(Y21) × ×

Forward start signal (Y22) ×

Reverse start signal (Y23) ×

  • In the speed-position control switch mode, if Speed-position mode restart signal (Y26) is turned on in a

status other than stop, the error "Restart error" (error code: 85) occurs and the axis does not act.

Show 7 more labels / short text on this page
Speed change · Positioning speed · Stop signal · Changed speed · t · Speed-position mode · restart signal (Y26)
Page 238 of the Mitsubishi Electronics QD73A1 user manual — Item Value Condition to be 0001 H
Page 238 · click to enlarge
Page 238

CHAPTER 13 COMMON FUNCTIONS

Functions referred to as "common function" can be used regardless of control method when necessary.

Common functions can be used on GX Works2.

13.1 Module Status Monitor Function

The "module status monitor function" monitors the module information, switch setting information, and external I/O

signal information. The module's detailed information can be displayed on the system monitor of GX Works2.

(1) Hardware LED information

The following LED statuses are displayed.

Item Value Condition to be 0001 H

RUN

Operating normally (same as the RUN LED)

  • 0000 H : Indicates that the LED is off.

SV RDY Servo READY signal (READY) ON

  • 0001 H : Indicates that the LED is on.

DOG Near-point dog signal (DOG) ON

STOP Stop signal (STOP) ON

FLS Upper limit signal (FLS) ON

RLS Lower limit signal (RLS) ON

CHG Speed-position switching command signal (CHANGE) ON

Show 4 more labels / short text on this page
ERR Error occurrence · BUSY During positioning · ZERO Adjusting zero · GAIN Adjusting gain
Page 239 of the Mitsubishi Electronics QD73A1 user manual — 0: OFF, 1: ON
Page 239 · click to enlarge
Page 239

CHAPTER 13 COMMON FUNCTIONS

(2) Hardware switch information

The following switch setting statuses are displayed.

Item Switch setting Value

ROT DIR Rotation direction setting

ACCUM PLS Accumulated pulse setting

ZERO DIR OPR direction setting

Refer to Page 276, Appendix 4.1 (2).

OPR METHOD OPR method setting

ENC I/F Encoder I/F setting

RESOLT Analog voltage resolution setting

Mitsubishi Electronics QD73A1 — Item Switch setting Value diagram (page 239)
Fig. 113 · Item Switch setting Value

0: OFF, 1: ON

13.1 Module Status Monitor Function

Indicates that Servo READY signal (READY) is on.

For details on the system monitor of GX Works2, refer to the following.

GX Works2 Version1 Operating Manual (Common)

MULTI Multiplication setting

Page 240 of the Mitsubishi Electronics QD73A1 user manual — 13.2 Error History Function
Page 240 · click to enlarge
Page 240

13.2 Error History Function

This function monitors the QD73A1's error history stored in the buffer memory.

The error history of past 16 records can be monitored. Once 16 records are stored, the next record overwrites the

oldest record. Therefore, the latest 16 errors are stored at all times.

Mitsubishi Electronics QD73A1 — 13.2 Error History Function diagram (page 240)
Fig. 114 · 13.2 Error History Function

To check the error history, the QD73A1 needs to be registered in the intelligent function module monitor window. For

how to register the module in the intelligent function module monitor window and to display the details of the history,

refer to the following.

GX Works2 Version1 Operating Manual (Intelligent Function Module)

To monitor the error history directly through the buffer memory, refer to the following.

Page 85, Section 5.5

Page 241 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 13 COMMON FUNCTIONS
Page 241 · click to enlarge
Page 241

CHAPTER 13 COMMON FUNCTIONS

13.3 Module Error Collection Function

Errors that occurred in the QD73A1 are collected into the CPU module.

The error information of the QD73A1 module is held in a CPU module memory as a module error history, even when

the power is turned off or the CPU module is reset.

Mitsubishi Electronics QD73A1 — CHAPTER 13 COMMON FUNCTIONS diagram (page 241)
Fig. 115

Error history (CPU module) and error log (intelligent function module) are displayed on one screen.

Errors that are detected in the entire base system can be monitored in chronological order.

CPU 19:29 Error A1 is detected! 19:36 Error A2 is detected! 19:34 Error B1 is detected!

Time Module with error Error code 19:29 19:34 19:36

For details on the module error collection function, refer to the following.

Page 242 of the Mitsubishi Electronics QD73A1 user manual — 13.4 Error Clear Function
Page 242 · click to enlarge
Page 242

13.4 Error Clear Function

When an error occurs, the error can be cleared on the system monitor.

By clicking the button in the system monitor, the error codes stored in " Error code (ERR.1)" and

Md.3

" Error code (ERR.2)" are cleared, and the ERR. LED turns off. This operation is the same as the one that uses

Md.4

Error reset signal (Y28).

However, the error history cannot be cleared with the button.

For the error clearing method using Error reset signal (Y28), refer to the following.

Page 38, Section 3.4.3 (12)

[Diagnostics] [System Monitor...] Error module

Mitsubishi Electronics QD73A1 — 13.4 Error Clear Function diagram (page 242)
Fig. 116 · 13.4 Error Clear Function
Page 243 of the Mitsubishi Electronics QD73A1 user manual — When an error is indicated on a module other than
Page 243 · click to enlarge
Page 243

CHAPTER 14 TROUBLESHOOTING

CHAPTER 14 TROUBLESHOOTING

This chapter describes errors that may occur in the QD73A1 and troubleshooting for them.

14.1 Checking an Error on GX Works2

The error codes that occurred in the QD73A1 can be checked by the following.

Choose a method depending on the purpose and application.

  • Checking on the "Module's Detailed Information" window
  • Checking on the "Error History" window

(1) Checking on the "Module's Detailed Information" window

Follow the procedure below.

1. Connect GX Works2 to the CPU module, and display

Mitsubishi Electronics QD73A1 — 1. Connect GX Works2 to the CPU module, and display diagram (page 243)
Fig. 117 · 1. Connect GX Works2 to the CPU module, and display

the "System Monitor" window.

[Diagnostics] [System Monitor...]

14.1 Checking an Error on GX Works2

2. After confirming that an error is displayed on the

Mitsubishi Electronics QD73A1 — 2. After confirming that an error is displayed on the diagram (page 243)
Fig. 118 · 2. After confirming that an error is displayed on th…

QD73A1, select the QD73A1 and click the

button.

When an error is indicated on a module other than

the QD73A1, refer to the user's manual for the

module and take a corrective action.

(To the next page)

Page 244 of the Mitsubishi Electronics QD73A1 user manual — (a) Error History List
Page 244 · click to enlarge
Page 244

(From the previous page)

3. Click the button to display the

"Module's Detailed Information" window.

The error detail and solution can be checked under

"Error and Solution"

(2) Checking on the "Error History" window

An error history that includes errors in the QD73A1 and other modules is displayed in a list, and it can be output

to a CSV file. The error codes and the error occurrence time can be checked even after the power was turned off

and on or the CPU module was reset.

[Diagnostics] [System Monitor...] button

Mitsubishi Electronics QD73A1 — The error detail and solution can be checked under diagram (page 244)
Fig. 119 · The error detail and solution can be checked under

(a) Error History List

Error logs of modules are displayed in a list.

(a) · (b) · (c)

Page 245 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 14 TROUBLESHOOTING
Page 245 · click to enlarge
Page 245

CHAPTER 14 TROUBLESHOOTING

(b) Error and Solution, Intelligent Module Information

  • Error and Solution: Displays the detail and corrective action for the error selected on "Error History List".
  • Intelligent Module Information: Displays the QD73A1's status at the occurrence of the error selected on

"Error History List".

For the QD73A1, the following are displayed.

Current feed value The current value at the time of the error occurrence is stored.

Actual current value The actual current value at the time of the error occurrence is stored.

State of the input signal (Xn0 to XnF) The status of input signals (X0 to XF) at the time of error occurrence is stored (in

hexadecimal).

State of the input signal (X(n+1)0 to X(n+1)F) The status of input signals (X10 to X1F) at the time of error occurrence is stored (in

hexadecimal).

State of the output signal (Yn0 to YnF) The status of output signals (Y0 to YF) at the time of error occurrence is stored (in

hexadecimal).

State of the output signal (Y(n+1)0 to Y(n+1)F) The status of output signals (Y10 to Y1F) at the time of error occurrence is stored (in

hexadecimal).

WDT error H/W error signal

14.1 Checking an Error on GX Works2

The statuses of input signals (X) at the time of error occurrence are stored.

OPR start complete signal

Absolute positioning start complete signal

Forward start complete signal

Reverse start complete signal

Zero/gain adjustment data writing complete flag

Zero/gain adjustment change complete flag

Set value change complete signal

Operating status of the speed-position control

Show 18 more labels / short text on this page
Item Description · QD73A1 READY signal · OPR request signal · OPR complete signal · BUSY signal · Positioning complete signal · In-position signal · Excessive error signal · Error detection signal · Overflow signal · Underflow signal · Servo READY signal · Near-point dog signal · External stop signal · Upper limit signal · Lower limit signal · Synchronization flag · switch mode
Page 246 of the Mitsubishi Electronics QD73A1 user manual — (c) Button to create a CSV file
Page 246 · click to enlarge
Page 246

(c) Button to create a CSV file

An error history is output to a CSV file.

If errors occur in the QD73A1 frequently, "*HST.LOSS*" may be displayed under "Error Code" instead of an actual error code.

Mitsubishi Electronics QD73A1 — (c) Button to create a CSV file diagram (page 246)
Fig. 120 · (c) Button to create a CSV file

If "*HST.LOSS*" is displayed frequently, set a large value for the number of errors collected per scan under the "PLC RAS" tab in "PLC Parameter". For the setting, refer to the following.

The user's manual (Function Explanation, Program Fundamentals) for the CPU module used

Page 247 of the Mitsubishi Electronics QD73A1 user manual — CHAPTER 14 TROUBLESHOOTING
Page 247 · click to enlarge
Page 247

CHAPTER 14 TROUBLESHOOTING

14.2 Troubleshooting

14.2.1 Troubleshooting procedure

This section shows the troubleshooting procedure for the QD73A1.

Mitsubishi Electronics QD73A1 — CHAPTER 14 TROUBLESHOOTING diagram (page 247)
Fig. 121

Check the LED on the front of the QD73A1.

Is the work operating in the set speed? NO

Page 248 of the Mitsubishi Electronics QD73A1 user manual — Check item Action
Page 248 · click to enlarge
Page 248

14.2.2 When the motor does not stop

Check item Action

Is the QD73A1's zero adjustment performed properly? Perform zero adjustment. ( Page 59, Section 4.5)

Is the servo amplifier's zero adjustment performed properly? Refer to the manual for the servo amplifier, and perform zero adjustment.

Is a large value set to the gain value of the servo amplifier? Refer to the manual for the servo amplifier, and adjust the gain value of the

servo amplifier to a proper value.

Are the speed command terminal on the QD73A1 and the

servo amplifier connected properly?

Connect the speed command terminals properly.

(when the motor does not stop even though the speed

command from the QD73A1 is 0V)

  • Place signal lines away from power cables.
  • Use shielded twisted pair cables for signal lines.

Is there noise effect?

  • Ground cables without fail.
  • Place the motor away from noise source.

14.2.3 When positioning cannot be executed

Check item Action

Is PLC READY signal

(Y2D) off? Turn on PLC READY signal (Y2D).

  • Turn on Servo READY signal.

Is Servo READY signal

  • Check if there is any error on the servo amplifier.
  • Check if the QD73A1 and the servo amplifier are wired properly.

Read out the error code, and take the corrective action described in the error code list.

Is the ERR. LED on?

( Page 252, Section 14.3.4)

[Double-check the sequence program.]

  • Check if an interlock is made at a start.
  • Check if Stop signal (Y27) is on.
  • Check if the start is kept reset.

Is the BUSY LED off?

  • Check if the start signal is kept on.

[Check the QD73A1's status.]

  • Check if the QD73A1 is mounted on the base unit properly.
  • Check if the position setting is proper.

The accumulated pulse amount is outside the setting range.

  • Check if the accumulated pulse setting is proper. ( Page 102, Section 6.2.2)

Is Excessive error signal

  • Check if the multiplication setting is proper. ( Page 104, Section 6.2.3)
  • Check if the encoder I/F setting is proper. ( Page 105, Section 6.2.6)
  • Check if the gain adjustment is proper. ( Page 59, Section 4.5)
  • Check if the QD73A1 and the encoder are connected properly. ( Page 66, Section 4.6.2)

Is External stop signal

  • Check if Stop signal (Y27) is on.
  • Check if Stop signal (STOP) is on.

Is WDT error, H/W error

If WDT error, H/W error signal (X10) stays on even after resetting the CPU module, please consult your local

Mitsubishi representative.

Are the QD73A1 and the

Check if the QD73A1 and the drive unit are wired properly.

Show 6 more labels / short text on this page
(X1B) off? · (X17) on? · (X1D) on? · signal (X10) on? · drive unit connected · properly?
Page 249 of the Mitsubishi Electronics QD73A1 user manual — Check item Action
Page 249 · click to enlarge
Page 249

CHAPTER 14 TROUBLESHOOTING

Check item Action

Is proper wave output

terminal is connected to an

If proper wave output is not displayed, please consult your local Mitsubishi representative. Is proper wave output

displayed when the drive

terminal is connected to an

14.2.4 When a positioning error occurs

Check item Action

[Double-check the parameters.]

  • Check if the set position is proper according to the machine position.
  • Check the positioning parameters and positioning data.
  • Check the accumulated pulse setting. ( Page 102, Section 6.2.2)
  • Check the multiplication setting. ( Page 104, Section 6.2.3)

Do the position errors occur by regular amount?

[Double-check the sequence program.]

  • Check if a proper address is set.
  • Check if a proper value is set for a current value change.
  • Check if a stop signal is input.
  • Check if the set movement amount is too small for operation in the speed-

position control switch mode.

14.2 Troubleshooting 14.2.4 When a positioning error occurs

Is the motor rotating smoothly? Check if the feedback pulse frequency is within 1Mpulse/s using an

oscilloscope.

  • Place signal lines away from power cables.
  • Use shielded twisted pair cables for signal lines.

Is there noise effect?

  • Ground cables without fail.
  • Place each device in the system away from noise source.
Show 5 more labels / short text on this page
displayed when the · QD73A1's speed command · oscilloscope? · unit's encoder output · oscilloscope?
Page 250 of the Mitsubishi Electronics QD73A1 user manual — Check item Action
Page 250 · click to enlarge
Page 250

14.2.5 When the positioning speed is different from the specified speed

Check item Action

Are the positioning data set properly? Set proper positioning data.

Is the set positioning speed value greater than " Speed

Pr.5 Pr.5

Set a positioning speed value that is smaller than " Speed limit

value".

Calculate the maximum accumulated pulse amount, and review the

Is the accumulated pulse setting proper?

accumulated pulse setting. ( Page 102, Section 6.2.2)

Is the zero/gain adjustment proper? Perform zero/gain adjustment again. ( Page 59, Section 4.5)

Is the multiplication setting proper? Configure the multiplication setting properly. ( Page 104, Section

6.2.3)

Is the servo amplifier set properly? Refer to the manual for the servo amplifier, and set the servo amplifier

properly.

Is a speed change executed? Review the sequence program to see if the speed change is necessary.

Is proper wave output displayed when the QD73A1's speed

command terminal is connected to an oscilloscope? If proper wave output is not displayed, please consult your local Mitsubishi

representative. Is proper wave output displayed when the drive unit's

encoder output terminal is connected to an oscilloscope?

14.2.6 When operation stops abnormally during positioning

Check item Action

Is there an error on the servo amplifier? Refer to the manual for the servo amplifier, and check the error detail.

Is Stop signal (Y27) on? Review the sequence program to see if Stop signal (Y27) needs to be turned on.

Is Stop signal (STOP) on? Check if Stop signal (STOP) is wired properly.

The accumulated pulse amount is outside the setting range.

Is Excessive error signal (X17) on?

Check if the accumulated pulse setting is proper. ( Page 102, Section 6.2.2)

  • Place signal lines away from power cables.
  • Use shielded twisted pair cables for signal lines.

Is there noise effect?

  • Ground cables without fail.
  • Place each device in the system away from noise source.

limit value"?

Page 251 of the Mitsubishi Electronics QD73A1 user manual — Check item Action
Page 251 · click to enlarge
Page 251

CHAPTER 14 TROUBLESHOOTING

14.2.7 OPR error

(1) When OPR cannot be completed

Check item Action

Does Near-point dog signal (DOG) stay off? Check if Near-point dog signal (DOG) is wired properly.

Does the speed change to the creep speed after Near-point

dog signal (DOG) turned on? The QD73A1 may be broken. Please consult your local Mitsubishi

representative. Does analog output from the QD73A1 continue after a Zero

Does Zero signal stay off? Check if Zero signal is wired properly.

(2) When the OP position is in error

Check item Action

If the position where the near-point dog turns off is near the position of a

Zero signal input, the Zero signal input may be misread. Adjust the position

where the near-point dog turns off to be closer to the center of Zero signals.

Do the position errors occur by regular amount?

If the position after the move according to " Setting for the movement

Pr.13

amount after near-point dog ON" is near the position of a Zero signal input,

the Zero signal input may be misread. Adjust " Setting for the

Pr.13

movement amount after near-point dog ON" so that the position after the

move becomes closer to the center of Zero signals.

Is the OPR completed near the position where Near-point

Near-point dog signal (DOG) may be chattering. Use a high-performance

14.2 Troubleshooting 14.2.7 OPR error

dog signal (DOG) turns on?

near-point dog.

Is the OPR in the near-point dog method completed even

though the near-point dog did not turn off? The contact or wiring of the near-point dog is not proper. Check the wiring.

In the near-point dog method, is the movement amount after

Near-point dog signal (DOG) may be chattering when it turns off. Use a

near-point dog ON more than that of normal OPR completion

high-performance near-point dog.

by one or more servomotor rotation?

signal input? · [Near-point dog method] · [Count method]

Page 252 of the Mitsubishi Electronics QD73A1 user manual — (5) Zero/gain adjustment error
Page 252 · click to enlarge
Page 252

14.3 Details of Errors

14.3.1 Types of errors

The errors detected in the QD73A1 are categorized into five types.

(1) Setting data range error

The QD73A1 checks parameters with the setting ranges at the following timings, and detects an error when a

data is outside the setting range. If an error occurs, the corresponding data must be changed to a value within the

setting range.

Setting data Check timing

Fixed parameters When PLC READY signal (Y2D) is turned on

When a positioning start signal (Y21 to Y23) is turned on

When a JOG start signal (Y24, Y25) is turned on

When OPR start signal (Y20) is turned on

OPR parameters When OPR start signal (Y20) is turned on

Positioning data When a positioning start signal (Y21 to Y23) is turned on

Control change areas Before the execution of a control change

(2) Start error

Start error is a type of errors that occur at a start of OPR control, major positioning control, or JOG operation.

Operation does not start if an error occurs.

(3) Operation error

Operation error is a type of errors that occur during OPR control, major positioning control, or JOG operation.

If an error occurs, operation decelerates and stops or continues without decelerating depending on the error

detail.

For the operation at the error occurrence, refer to the following.

( Page 252, Section 14.3.4)

(4) Control change error

Control change error is a type of errors that occur at a control change during positioning.

The data for the control change is ignored if an error occurs.

(5) Zero/gain adjustment error

Zero/gain adjustment error is a type of errors that occur during zero/gain adjustment.

The details of the zero/gain adjustment are not reflected in the QD73A1 if an error occurs. Eliminate the error

cause, and perform zero/gain adjustment again.

Variable parameters

Page 253 of the Mitsubishi Electronics QD73A1 user manual — 14.3.3 Error reset
Page 253 · click to enlarge
Page 253

CHAPTER 14 TROUBLESHOOTING

14.3.2 Storage of errors

When an error occurs in the QD73A1, the corresponding error code is stored in the buffer memory.

(1) ERR.1 and ERR.2

Errors are classified into ERR.1 and ERR.2 depending on the error details.

Error classification Description

Errors caused due to sequence programs.

ERR.1 (minor errors)

Check the error code, and eliminate the error cause by correcting the sequence

program.

Hardware errors or errors caused due to control commands from external input

ERR.2 (major errors)

signals.

Check the error code, and eliminate the error cause on an external input signal.

(2) Buffer memory areas for error codes

The latest error codes are stored in the following buffer memory areas every time an error occurs, deleting the

previous error codes. When there is no error or when the errors were reset, "0" is stored.

Error classification Buffer memory area name Buffer memory address Corresponding error

detection signal

ERR.1 (minor errors) Error code (ERR.1) 104 Error detection signal (X18) ERR.2 (major errors) Error code (ERR.2) 105

Md.3

Md.4

14.3.3 Error reset

14.3 Details of Errors 14.3.2 Storage of errors

Eliminate the error cause according to the corrective action described in the error code list ( Page 252, Section

14.3.4), then cancel the error status by turning on Error reset signal (Y28).

At the time, the QD73A1 operates as follows.

1 Clears " Error code (ERR.1)" to 0.

Md.3

2 Clears " Error code (ERR.2)" to 0.

Md.4

3 Turns off Error detection signal (X18).

Page 254 of the Mitsubishi Electronics QD73A1 user manual — 1/50 CMX/CDV 50
Page 254 · click to enlarge
Page 254

14.3.4 Error code list

The following table describes error details and corrective actions.

Error

Error

classification Error name Description Operation at the

Error

code

error occurrence Action

category

(decimal)

The set value in

Pr.2

Set a value within the

lower limit" is outside -

setting range, and turn

on PLC READY signal

(Y2D).

Pr.1

upper limit".

The set value in

If a setting is outside

Set a value within the

Pr.3

setting range, and turn

the error occurs and

on PLC READY signal

all of the fixed

(Y2D).

range.

the control.

The set value in

Set a value within the

Pr.4

setting range, and turn

on PLC READY signal

(Y2D).

1 to 9999, and besides

range.

1/50 CMX/CDV 50

ERR.1

The set value in

Set a value within the

Pr.5

setting range.

value" is outside the

setting range.

The set value in

Set a value within the

Pr.6

setting range.

time" is outside the

setting range.

The set value in

Only the setting with

Set a value within the

Pr.7

the error uses the

setting range.

time" is outside the

setting range.

control.

The set value in

Set a value within the

setting range.

Pr.8

range" is outside the

setting range.

The set value in

Set a value within the

Pr.9

setting range.

mode" is other than 0

and 1.

Show 70 more labels / short text on this page
" Stroke limit · Stroke limit · lower limit · 2147483648 to · " Stroke limit · Numerator of · " Numerator of · command pulse · the setting range, · Setting data · command pulse · multiplication for · range error · multiplication for · electronic gear · (Fixed · electronic gear" is · Outside the · parameters use the · [Setting range] · parameter) · outside the setting · setting range · default values for · 1 to 9999 · Denominator of · " Denominator · command pulse · of command pulse · multiplication for · multiplication for · electronic gear · electronic gear" is · [Setting range] · Outside the · outside the setting · setting range · Speed limit · " Speed limit · value Outside · [Setting range] · the setting range · 10 to 4000000pulse/s · Acceleration · " Acceleration · time Outside the · [Setting range] · setting range · 2 to 9999ms · Setting data · Deceleration · range error · " Deceleration · time Outside the · (Variable · default value for · [Setting range] · setting range · parameter) · 2 to 9999ms · In-position range · Outside the · " In-position · [Setting range] · setting range · 1 to 20479pulse · Positioning · " Positioning · mode Outside · the setting range
Page 255 of the Mitsubishi Electronics QD73A1 user manual — ERR.1
Page 255 · click to enlarge
Page 255

CHAPTER 14 TROUBLESHOOTING

Error

Error

classification Error name Description Operation at the

Error

code

error occurrence Action

category

(decimal)

Set a value within the

The set value in

setting range.

Pr.11

is outside the setting

1 to " Speed limit

Pr.5

range.

Set a value within the

The set value in

setting range.

Pr.12

is outside the setting

1 to " OPR

Pr.11

range.

If a setting is outside

Set a value within the

setting range.

(OPR

the OPR does not

start.

The set value in

Pr.11

" Setting for the

Pr.13

Pr.12

ON" is outside the

" Setting for the

Pr.13

setting range.

ERR.1

checked only in the

count method.)

  • The positioning end
  • Set the positioning

point is outside the

end point within the

stroke limit range.

stroke limit range.

14.3 Details of Errors 14.3.4 Error code list

  • The set value of
  • Do not set a negative

system is a negative

value at the start. The positioning does

system at the start.

not start.

control in the absolute

Do not change the

moving direction for P1

direction from P1 to

to P2 from the direction

P2 is different from the

used to reach P1.

reach P1.

Show 52 more labels / short text on this page
OPR speed · " OPR speed" · [Setting range] · Outside the · setting range · value" (pulse/s) · Creep speed · " Creep speed" · [Setting range] · Outside the · setting range · speed" (pulse/s) · Setting data · range error · the setting range, · [Setting range] · parameter) · Deceleration distance · Setting for the · from " OPR · movement · speed" to " · amount after · movement amount · Creep speed" < · near-point dog · after near-point dog · ON Outside the · setting range · movement amount after · near-point dog ON" · (This condition is · Positioning · address Outside · positioning address · value to the · the setting range · in the incremental · positioning address · Setting data · in the incremental · range error · (Positioning · For two-phase · data) · trapezoidal positioning · Two-phase · trapezoidal · system, the moving · positioning · address error · direction used to
Page 256 of the Mitsubishi Electronics QD73A1 user manual — ERR.2
Page 256 · click to enlarge
Page 256

Error

Error

classification Error name Description Operation at the

Error

code

error occurrence Action

category

(decimal)

Set a value within the

setting range.

is outside the setting

range. The positioning does

1 to " Speed limit

Pr.5

not start when the

set value is 0. In

The set value in

Set a value within the

case of an error due

setting range.

Cd.2

to a set value other

ERR.1

value" is outside the

0 to " Speed limit

Pr.5

positioning operation.

Set a value within the

The set value in

Pr.5

setting range.

value".

Cd.3

is outside the setting

1 to " Speed limit

Pr.5

range.

  • Check the power

wiring of the drive

unit, as well as the

connectors.

(READY) is off at the

  • When using a drive

JOG operation.

devices so that the

on.

Stop signal (STOP) is

on at the start of major

Turn off Stop signal

(STOP).

ERR.2

JOG operation.

not start.

  • Return the workpiece

(FLS) is off at the start

to a position within

the stroke limit range

using JOG operation.

operation.

  • Check the power

wiring of the drive

unit, as well as the

(RLS) is off at the start

connectors.

  • If the system does

operation.

devices so that the

inputs stay on.

Show 72 more labels / short text on this page
Setting data · Positioning · The positioning speed · range error · [Setting range] · speed Outside · (Positioning · the setting range · data) · value" (pulse/s) · Setting data · range error · New speed · " New speed · [Setting range] · (Control · value Outside · than 0, the · change · the setting range · setting range in · positioning is · area) · controlled with · value" (pulse/s) · Setting data · " Speed limit · range error · JOG speed · " JOG speed" · [Setting range] · (Control · Outside the · change · setting range · area) · value" (pulse/s) · supply status and · connections of · Servo READY signal · Servo READY · start of major · OFF at start · unit without Servo · positioning, OPR, or · READY output, wire · QD73A1's Servo · READY signal · (READY) input stays · External stop · signal ON at · positioning, OPR, or · The operation does · Start error · start · Upper limit signal · Upper limit · signal OFF at · of major positioning, · start · OPR, or JOG · supply status and · Lower limit signal · connections of · Lower limit · signal OFF at · of major positioning, · start · OPR, or JOG · not need limit · switches, wire · QD73A1's LS signal
Page 257 of the Mitsubishi Electronics QD73A1 user manual — ERR.1
Page 257 · click to enlarge
Page 257

CHAPTER 14 TROUBLESHOOTING

Error

Error

classification Error name Description Operation at the

Error

code

error occurrence Action

category

(decimal)

Return the workpiece to

a position away from

(DOG) is on at the

74 ERR.2

start of OPR in the

using JOG operation or

method.

execute OPR.

QD73A1 READY

signal (X11) or PLC

Turn on PLC READY

(PLC READY

is off at the start of

signal (Y2D).

operation.

Make an interlock using

An operation start is

a sequence program so

81 BUSY signal ON

that no operation starts

BUSY signal (X14) is

on.

(X14) is on.

An operation start is

Turn off Stop signal

82 STOP signal ON

(Y27), and start the

signal (Y27) is on.

operation again.

not start.

  • Return the workpiece

to a position within

the stroke limit range

ERR.1

An operation start is

using JOG operation.

  • Execute OPR.
  • Set the workpiece to

14.3 Details of Errors 14.3.4 Error code list

the stroke limit range.

a position within the

stroke limit range by

value.

  • OPR cannot be

(only in the near-

point dog method).

An OPR start is

  • Move the workpiece

to the position before

is on.

OPR.

Show 37 more labels / short text on this page
Near-point dog signal · Near-point dog · the near-point dog · signal ON at · start · near-point dog · major positioning, then · READY signal · OFF at start · READY signal (Y2D) · signal OFF at · major positioning, · start) · OPR, or JOG · attempted when · at start · when BUSY signal · attempted when Stop · at start · The operation does · Start error · Outside the · attempted when the · stroke limit · workpiece is outside · range at start · changing the current · started in succession · OPR complete · attempted when OPR · signal ON at · complete signal (X13) · start · the near-point dog · using JOG operation · or major positioning, · then start another
Page 258 of the Mitsubishi Electronics QD73A1 user manual — BUSY
Page 258 · click to enlarge
Page 258

Error

Error

classification Error name Description Operation at the

Error

code

error occurrence Action

category

(decimal)

was turned on when

(Y22) or Reverse start

signal (Y23).

switch mode. The operation does

Start error 85 ERR.1 Restart error

not start.

was turned on in the

position control mode.

(Y22), or Reverse start

signal (Y23).

so that the workpiece is

attempted with a value

87 ERR.1

change.

stroke limit range after

the move.

stroke limit range.

Check the drive unit,

and turn on Servo

freely.

(READY).

JOG operation.

(FLS) turned off during

ERR.2

BUSY

Return the workpiece to

operation. The operation

a position within the

stroke limit range using

stops.

JOG operation.

BUSY

JOG operation.

Show 47 more labels / short text on this page
Speed-position mode · restart signal (Y26) · Start operation using · Forward start signal · positioning was · complete in the · speed-position control · Start operation using · Speed-position mode · Absolute positioning · restart signal (Y26) · start signal (Y21), · Forward start signal · A movement amount · Set movement amount · Movement · change was · The movement · outside the · amount does not · positioned within the · stroke limit · that moves the · range · workpiece outside the · Servo READY signal · (READY) turned off · Servo READY · The operation runs · during major · OFF while BUSY · READY signal · positioning, OPR, or · Operation · error · Upper limit signal · Upper limit · signal OFF while · major positioning, · OPR, or JOG · decelerates and · Lower limit signal · Lower limit · (RLS) turned off · signal OFF while · during major · positioning, OPR, or
Page 259 of the Mitsubishi Electronics QD73A1 user manual — ERR.1
Page 259 · click to enlarge
Page 259

CHAPTER 14 TROUBLESHOOTING

Error

Error

classification Error name Description Operation at the

Error

code

error occurrence Action

category

(decimal)

  • Start OPR if the

dog turns on in the

count method.

  • In the near-point dog

turns on, return the

93 ERR.2

turned on during OPR.

OPR

stops.

start OPR.

  • Start OPR if the

dog turns on.

Return the workpiece to

The OPR or JOG

a position within the

operation continues.

stroke limit range using

JOG operation.

operation.

102 STOP signal ON

Stop signal (Y27) was

  • Start OPR if the

turned on during OPR.

14.3 Details of Errors 14.3.4 Error code list

dog turns on in the

count method.

  • In the near-point dog

turns on, return the

ERR.1

PLC READY

stops.

(Y2D) was turned off

during OPR.

start OPR.

  • Start OPR if the

dog turns on.

The speed is limited

Change the speed to

4Mpulse/s due to the

4Mpulse/s or lower.

lower.

setting.

Show 53 more labels / short text on this page
workpiece stops · when the near-point · method, if the · workpiece stops after · the near-point dog · External stop · The operation · Stop signal (STOP) · signal ON during · decelerates and · workpiece to the · position before the · near-point dog turns · on using JOG · operation or major · positioning, and then · workpiece stops · before the near-point · The current value · Outside the · exceeded the stroke · stroke limit · limit range during · range · OPR or JOG · Operation · error · during OPR · workpiece stops · when the near-point · method, if the · workpiece stops after · the near-point dog · The operation · decelerates and · workpiece to the · PLC READY signal · position before the · signal OFF · near-point dog turns · during OPR · on using JOG · operation or major · positioning, and then · workpiece stops · before the near-point · The command · Outside the · frequency exceeded · command · to 4Mpulse/s or · frequency range · electronic gear
Page 260 of the Mitsubishi Electronics QD73A1 user manual — ERR.1
Page 260 · click to enlarge
Page 260

Error

Error

classification Error name Description Operation at the

Error

code

error occurrence Action

category

(decimal)

PLC READY

(Y2D) was turned off

Turn on PLC READY

signal (Y2D).

stops.

operation.

Make an interlock using

(X14) is on.

a sequence program.

A speed change was

OPR.

A speed change was

ERR.1

attempted at the start

program so that the

before the start of

is ignored.

thereafter.

of major positioning.

A speed change was

start signal (Y24, Y25)

was turned off in JOG

operation. Make an interlock using

a sequence program.

(X14) is on.

Show 40 more labels / short text on this page
PLC READY signal · The operation · Operation · error 105 · signal OFF · during major · decelerates and · during operation · positioning or JOG · A current value · 110 Current value · change is attempted · change error · when BUSY signal · 111 Speed change · attempted during · error (OPR) · Correct the sequence · Speed change · Control · of automatic · speed is changed · error · change error · deceleration of major · The control change · (Positioning) · during · positioning or · automatic deceleration · operation · attempted after JOG · 113 Speed change · error (JOG) · Deviation counter · Deviation · clearing is attempted · counter clear · when BUSY signal · error
Page 261 of the Mitsubishi Electronics QD73A1 user manual — ERR.1
Page 261 · click to enlarge
Page 261

CHAPTER 14 TROUBLESHOOTING

Error

Error

classification Error name Description Operation at the

Error

code

error occurrence Action

category

(decimal)

Turn off and on the

power supply, or reset

the CPU module or the

to the flash ROM more

error.

than 25 times.

Try writing the value

again.

If the error occurs

121 Flash ROM write

again, a failure might

setting value could not

have occurred on the

be written in the flash

module. Please consult

ROM.

representative.

Set the values so that

they meet the following

ERR.1

conditionZero

equal to or greater

are not reflected.

adjustment value.

The set value in

Set a value within the

Cd.10

setting range (1, 2) in

Cd.10

specification".

range.

The set value in

14.3 Details of Errors 14.3.4 Error code list

Set a value within the

Cd.11

setting range (-3000 to

Cd.11

value specification".

range.

Show 41 more labels / short text on this page
For zero/gain · adjustment, a setting · Flash ROM write · value has been · exceeded · consecutively written · For zero/gain · adjustment, the · error · your local Mitsubishi · For zero/gain · Zero/gain · adjustment, the zero · The zero/gain · adjustment · 122 Zero adjustment · adjustment value is · adjustment values · error · error · adjustment value < · than the gain · Gain adjustment value · " Zero/gain · Zero/gain · adjustment · adjustment · " Zero/gain · specification" is · setting error · adjustment · outside the setting · " Zero/gain · Zero/gain · adjustment value · adjustment · 3000) in " · specification" is · value error · Zero/gain adjustment · outside the setting
Page 262 of the Mitsubishi Electronics QD73A1 user manual — ERR.1
Page 262 · click to enlarge
Page 262

Error

Error

classification Error name Description Operation at the

Error

code

error occurrence Action

category

(decimal)

Set a value within the

setting range.

setting" in the switch

The set value in

setting. (Unitpulse)

Cd.5

  • Selection 1:

adjustment area 1" is

  • Selection 2:

range.

  • Selection 3:
  • Default value,

selection 4:

ERR.1

are not reflected.

Set a value within the

setting range.

The set value in

setting" in the switch

Cd.9

setting. (Unitpulse)

adjustment area 2" is

  • Selection 5:

range.

  • Selection 6:
  • Selection 7:
  • Selection 8:
Show 31 more labels / short text on this page
[Setting range] · Depends on · "Accumulated pulse · Analog output · adjustment area · " Analog output · 1 Outside the · -3700 to 3700 · setting range · outside the setting · -7400 to 7400 · -11100 to 11100 · Zero/gain · The zero/gain · -14800 to 14800 · adjustment · adjustment values · error · [Setting range] · Depends on · "Accumulated pulse · Analog output · " Analog output · adjustment area · 2 Outside the · outside the setting · -37000 to 37000 · setting range · -74000 to 74000 · -111000 to 111000 · -148000 to 148000
Page 263 of the Mitsubishi Electronics QD73A1 user manual — ERR.1
Page 263 · click to enlarge
Page 263

CHAPTER 14 TROUBLESHOOTING

Error

Error

classification Error name Description Operation at the

Error

code

error occurrence Action

category

(decimal)

continues.

level.

  • The number of
  • Measure the

unmeasured.

  • Either of the values

function.

Cd.13

  • Set the values of

Cd.13

Cd.14

Cd.16

range. Moreover,

either of the values

range.

executed.

  • Change the value of

ERR.1

Cd.15

Cd.17

14.3 Details of Errors 14.3.4 Error code list

selection" to 0 and

Cd.16

Cd.13

range.

Cd.16

  • " Accumulated

Cd.17

selection" is set to 1

(minimum value)".

are set to 0.

Cd.20

value and then, write

was set to 1 when the

the value.

is not written to the

(Write the value when

flash ROM.

Md.20

Md.20

flag" is set to 1.)

flag" was set to 0).

Show 82 more labels / short text on this page
Accumulated pulses · Accumulated · The positioning · reached the alert · pulse alert · accumulated pulses · used as the · reference of the · accumulated pulse · error detection · reference value and · function is · then, execute the · accumulated pulse · error detection · in " Alert · output accumulated · pulse setting value · " Alert output · (maximum value)" · accumulated pulse · and · setting value · (maximum value)" to · " Immediate · stop accumulated · " Immediate · pulse setting value · stop accumulated · (maximum value)" is · pulse setting value · The accumulated · Accumulated · outside the setting · (minimum value)" · pulse error detection · pulse error · within the setting · Accumulated · function is not · undetectable · pulse error · in " Alert · detection · output accumulated · " Accumulated · function · pulse setting value · pulse setting value · error · (minimum value)" · and · review the setting · values of · " Immediate · stop accumulated · " Alert output · pulse setting value · accumulated pulse · (minimum value)" is · setting value · outside the setting · (maximum value)" to · " Immediate · stop accumulated · pulse setting value · pulse setting value · and the · maximum/minimum · reference values · " Reference · Measure the reference · value write request" · The reference value · 132 Reference value · measurement was not · write error · being executed · " Reference · (" Reference · value measurement · value measurement
Page 264 of the Mitsubishi Electronics QD73A1 user manual — ERR.2
Page 264 · click to enlarge
Page 264

Error

Error

classification Error name Description Operation at the

Error

code

error occurrence Action

category

(decimal)

Turn off and on the

power supply or reset

written to the flash

the CPU module, or

ROM more than 25

clear the error.

times. The measured

ERR.1

Write the value again.

not saved in the

If the error occurs

flash ROM.

again, a failure might

134 Flash ROM write

have occurred on the

not be written in the

module. Please consult

flash ROM.

representative.

The setting for the

Set "Clear" to the CPU

QD73A1 is "Hold" on

not operate.

Mode".

Output Mode".

At startThe module

does not operate.

occurring on the CPU

The CPU has a

During operation:

module, and refer to the

problem.

user's manual for the

ERR.2

CPU module used.

stops.

900 Hardware error 1

Turn off and on the

power supply.

If the error occurs

The hardware has a

again, a failure might

problem. The system stops.

999 Hardware error 2

have occurred on the

module. Please consult

representative.

Show 30 more labels / short text on this page
The measured · reference value has · Flash ROM write · been consecutively · exceeded · Accumulated · pulse error · reference value is · detection · function · The measured · error · reference value could · error · your local Mitsubishi · The module does · module's parameter · Hold error · a CPU module's · "Error Time Output · parameter "Error Time · I/F error · Check the error · Programmable · controller CPU · The operation · error · decelerates and · Fatal error · your local Mitsubishi
Page 265 of the Mitsubishi Electronics QD73A1 user manual — (1) Switch setting
Page 265 · click to enlarge
Page 265

APPENDICES

APPENDICES

Appendix 1 Functions Added or Changed

Appendix 1.1 Functions added

The following lists the functions added to the QD73A1 and corresponding product information.

Function QD73A1 product information

(first five digits) Reference

Accumulated pulse error detection function 14082 or later Page 223, Section 11.9

Feedback pulse addition/subtraction setting

Page 106, Section 6.2.8

Deviation counter clear setting Page 107, Section 6.2.9

Deviation counter value (pulse) monitor Page 85, Section 5.5

Movement amount after near-point dog ON (absolute value) 16082 or later Page 85, Section 5.5

A

Appendix 1.2 Functions changed

The following lists the changed function of the QD73A1 and corresponding product information.

Function QD73A1 product information

(first five digits) Reference

Appendix 1 Functions Added or Changed Appendix 1.1 Functions added

Switch setting 15042 or later Page 276, Appendix 4.1 (2)

(1) Switch setting

The feedback pulse addition/subtraction setting and the deviation counter clear setting can be configured in the

switch setting.

(a) When the QD73A1 that does not support the changed function is used

The feedback pulse addition/subtraction setting and the deviation counter clear setting cannot be configured in

the switch setting.

15042 or later

Page 266 of the Mitsubishi Electronics QD73A1 user manual — CN1 MR-J3A
Page 266 · click to enlarge
Page 266

Appendix 2 Connection Examples

Appendix 2.1 Example of connection with a servo amplifier manufactured by Mitsubishi Electric Corporation

(1) Connection with MR-J3 A (Differential driver)

DOG Near-point dog signal QD73A1

CN1 MR-J3A

1 2 3 4 5 6 7 8 9

N.C. N.C. N.C. Power supply (5 to 24V) RLS Lower limit signal FLS Upper limit signal

CONT. connector

CHANGE Speed-position switching command signal STOP Stop signal

READY Servo READY signal (+ side) READY Servo READY signal (- side)

PULSE A Phase-A feedback pulse (+ side)

LA Encoder A-phase pulse (differential line driver) LAR Encoder A-phase pulse (differential line driver)

PULSE A Phase-A feedback pulse (- side)

PULSE B Phase-B feedback pulse (+ side)

LB Encoder B-phase pulse (differential line driver) LBR Encoder B-phase pulse (differential line driver)

PULSE B Phase-B feedback pulse (- side)

PULSE Z Phase-Z feedback pulse (+ side)

LZ Encoder Z-phase pulse (differential line driver) LZR Encoder Z-phase pulse (differential line driver)

PULSE Z Phase-Z feedback pulse (- side)

SVON Servo ON signal (- side) SVON Servo ON signal (+ side)

Speed command signal (+ side) Speed command signal (- side)

VC Analog speed command LG Control common

N.C. Analog GND N.C.

20 21 46 47

DICOM Digital I/F power supply input DICOM Digital I/F power supply input DOCOM Digital I/F common DOCOM Digital I/F common

ST1 Forward rotation start ST2 Reverse rotation start

LG Control common LG Control common

EMG Emergency stop LSP Forward rotation stroke end LSN Reverse rotation stroke end

*1 indicates use of shielded cables. Use shielded cables for wiring.

*2 indicates use of shielded twisted pair cables. Use shielded twisted pair cables for wiring.

Show 8 more labels / short text on this page
*1 · External power supply · *2 · RD Ready · SERVO connector · LG Control common · SON Servo-on · External power supply
Page 267 of the Mitsubishi Electronics QD73A1 user manual — SG
Page 267 · click to enlarge
Page 267

APPENDICES

Appendix 2.2 Example of connection with a servo amplifier manufactured by YASKAWA Electric Corporation

(1) Connection with -V series (Differential driver)

  • For DC power supply input type

DOG Near-point dog signal QD73A1 CN1 -V series

1 2 3 4 5 6 7 8 9

N.C. N.C. N.C. Power supply (5 to 24V) RLS Lower limit signal FLS Upper limit signal

CONT. connector

CHANGE Speed-position switching command signal STOP Stop signal

READY Servo READY signal (+ side) READY Servo READY signal (- side)

S-RDY 11 COM-SG

PULSE A Phase-A feedback pulse (+ side)

PAO /PAO

A

PULSE A Phase-A feedback pulse (- side)

PULSE B Phase-B feedback pulse (+ side)

PBO /PBO

PULSE B Phase-B feedback pulse (- side)

PULSE Z Phase-Z feedback pulse (+ side)

PCO /PCO

PULSE Z Phase-Z feedback pulse (- side)

Appendix 2 Connection Examples Appendix 2.2 Example of connection with a servo amplifier manufactured by YASKAWA Electric Corporation

SVON Servo ON signal (- side) SVON Servo ON signal (+ side)

/S-ON

14 +24VIN

Speed command signal (+ side) Speed command signal (- side)

V-REF SG

N.C. Analog GND N.C.

SG

External power supply · SERVO connector

Page 268 of the Mitsubishi Electronics QD73A1 user manual — SG
Page 268 · click to enlarge
Page 268
  • For AC power supply input type

DOG Near-point dog signal QD73A1 CN1 -V series

1 2 3 4 5 6 7 8 9

N.C. N.C. N.C. Power supply (5 to 24V) RLS Lower limit signal FLS Upper limit signal

CONT. connector

CHANGE Speed-position switching command signal STOP Stop signal

READY Servo READY signal (+ side) READY Servo READY signal (- side)

/S-RDY+ 30 /S-RDY-

PULSE A Phase-A feedback pulse (+ side)

PAO /PAO

PULSE A Phase-A feedback pulse (- side)

PULSE B Phase-B feedback pulse (+ side)

PBO /PBO

PULSE B Phase-B feedback pulse (- side)

PULSE Z Phase-Z feedback pulse (+ side)

PCO /PCO

PULSE Z Phase-Z feedback pulse (- side)

SVON Servo ON signal (- side) SVON Servo ON signal (+ side)

/S-ON

47 +24VIN

Speed command signal (+ side) Speed command signal (- side)

V-REF SG

N.C. Analog GND N.C.

SG

External power supply · SERVO connector

Page 269 of the Mitsubishi Electronics QD73A1 user manual — A
Page 269 · click to enlarge
Page 269

APPENDICES

Appendix 3 Comparison of the QD73A1 and the AD70/A1SD70

(1) Performance specification comparison

Specifications

Item

QD73A1 AD70 A1SD70

Number of occupied I/O points 48 points (I/O assignment: empty 16 points and

32 points (special 32

assignmentempty 16

points and special 32

Speed command 1 to 4000000(pulse/s) 1 to 400000(pulse/s)

In-position range 1 to 20479pulse 1 to 2047pulse

Open collector200kpulse/s
Open collector100kpulse/s
TTL200kpulse/s
TTL100kpulse/s
Differential output1Mpulse/s
Differential output100kpulse/s

With OPR address change

With OPR address change

A

OPR method and OPR direction depend on the

OPR method and OPR direction depend on the

parameter setting.

switch setting.

Internal current consumption 5VDC 0.52A 5VDC 0.3A

terminal block No external power supply +15VDC 0.2A, -15VDC, 0.02A

External dimensions 98(H)mm × 55.2(W)mm × 90(D)mm 250(H)mm × 37.5(W)mm

130(H)mm × 69.5(W)mm

× 93.6(D)mm

Weight 0.20kg 0.5kg 0.4kg

Appendix 3 Comparison of the QD73A1 and the AD70/A1SD70

Absolute system1.2ms (same for two-phase
Absolute system4.4ms (additional 0.2ms for two-
Incremental system1.2ms (same for two-phase
Incremental system4.5ms (additional 0.2ms for

(from a start request to analog

JOG operation1.2ms
JOG operation4.3ms
OPR (near-point dog method)1.2ms
OPR (near-point dog method)4.4ms
OPR (count method)1.2ms
OPR (count method)5.1ms
Show 18 more labels / short text on this page
48 points (I/O · intelligent 32 points) · points) · points) · Positioning · Positioning · feedback · Pulse frequency · pulse input · OPR control · External supply voltage/current · × 119(D)mm · trapezoidal positioning) · phase trapezoidal positioning) · Starting time · trapezoidal positioning) · two-phase trapezoidal positioning) · output start)
Page 270 of the Mitsubishi Electronics QD73A1 user manual — LED
Page 270 · click to enlarge
Page 270

Specifications

Item

QD73A1 AD70 A1SD70

ERR. ERR.1/ERR.2 (Minor/major error)

None (check with X signal) SV RDY (Servo READY signal)

None (check with X signal) DOG (Near-point dog signal)

None (check with X signal) STOP (Stop signal)

None (check with X signal) FLS (Upper limit signal)

LED

None (check with X signal) RLS (Lower limit signal)

None (check with X signal) IN-POS. (In-position)

None (check in the buffer memory) POLE (Deviation counter polarity)

None (check in the buffer memory) 2N (Deviation counter value)

None (check with Y signal) PC RDY (PLC READY signal)

None (check with X signal) ZERO (OPR request signal)

None (check with X signal) EEX (Excessive error)

None (check with X signal) WDT ERR. (Hardware error)

None (check with X signal) V-MODE (Operating status)

Zero/gain adjustment • Adjustment using the UP/DOWN switch

  • Adjustment using the buffer memory Adjustment using volumes

Mode switch Intelligent function module switch DIP switch

All the other specifications are the same.

RUN None · ZERO None · GAIN None

Page 271 of the Mitsubishi Electronics QD73A1 user manual — APPENDICES
Page 271 · click to enlarge
Page 271

APPENDICES

(2) Function comparison

Mitsubishi Electronics QD73A1 — APPENDICES diagram (page 271)
Fig. 122

amount after near-point dog ON, which is the same

  • QD73A1: The setting is cleared to 0 when the next

Appendix 3 Comparison of the QD73A1 and the AD70/A1SD70

  • AD70/A1SD70: Stroke limit lower limit to upper limit
  • QD73A1: The current value can be changed by setting
  • AD70/A1SD70: The current value can be changed by

writing a new current value in the buffer memory.

  • QD73A1: Speed can be changed by setting "1" in
  • AD70/A1SD70: Speed can be changed by writing a
Page 272 of the Mitsubishi Electronics QD73A1 user manual — Function QD73A1 AD70/A1SD70 Difference
Page 272 · click to enlarge
Page 272

Function QD73A1 AD70/A1SD70 Difference

Accumulated pulse error detection

  • QD73A1: Switches on the front of the QD73A1 or a
  • AD70/A1SD70: Switches on the AD70/A1SD70

Module status monitor function ×

Error history function ×

Module error collection function ×

Error clear function ×

Show 4 more labels / short text on this page
function × · [Method] · Zero/gain adjustment · sequence program
Page 273 of the Mitsubishi Electronics QD73A1 user manual — (3) Error code comparison
Page 273 · click to enlarge
Page 273

APPENDICES

Remark

Positioning execution time (BUSY signal (X14) ON to Positioning complete signal (X15) ON) of the QD73A1 and AD70/A1SD70 may be different since their internal processing methods are different. As a result, the timing when In-position signal (X16) turns on may also vary. Adjust positioning execution time using the following methods if the difference of the execution time (or the timing when In- position signal (X16) turns on) affects the system.

  • Adjusting the QD73A1's positioning parameter " Acceleration time" or " Deceleration time"
  • Increasing gain by changing the accumulated pulse amount setting through the QD73A1's zero/gain adjustment

Pr.6 Pr.7

(3) Error code comparison

Mitsubishi Electronics QD73A1 — (3) Error code comparison diagram (page 273)
Fig. 123 · (3) Error code comparison

Appendix 3 Comparison of the QD73A1 and the AD70/A1SD70

Page 274 of the Mitsubishi Electronics QD73A1 user manual — Device No. *1 Signal name QD73A1 AD70/A1SD70
Page 274 · click to enlarge
Page 274

(4) Input (X)/output (Y) comparison

: Usable ×: Unusable

Device No. *1 Signal name QD73A1 AD70/A1SD70

X20 OPR start complete signal ×

X21 Absolute positioning start complete signal ×

X22 Forward start complete signal ×

X23 Reverse start complete signal ×

X24 Synchronization flag ×

X2A Zero/gain adjustment data writing complete flag ×

X2B Zero/gain adjustment change complete flag ×

X2C Set value change complete flag ×

X2D Operating status of the speed-position control

Y1A Zero/gain adjustment data writing request signal ×

Y1B Zero/gain adjustment change request signal ×

Y1C Set value change request signal ×

*1 For assignment to X/Y10 to X/Y2F

All the other I/O signals are the same.

switch mode ×

Page 275 of the Mitsubishi Electronics QD73A1 user manual — A
Page 275 · click to enlarge
Page 275

APPENDICES

(5) Buffer memory address comparison

Buffer memory address (decimal)

Buffer memory area name

QD73A1 AD70/A1SD70

Current value change request 90

Speed change request 91

Analog output adjustment area 2

Zero/gain adjustment specification 94

Zero/gain adjustment value specification 95

Factory default zero/gain adjustment value

Zero/gain execution status 112

Zero/gain adjustment status 113

Deviation counter value (pulse)

A

Movement amount after near-point dog ON

Error history (0 to 16) 120 to 183

Error history pointer 184

Maximum accumulated pulse value

Appendix 3 Comparison of the QD73A1 and the AD70/A1SD70

Minimum accumulated pulse value

Accumulated pulse error detection function status 204

Reference value measurement flag 205

Positioning pattern 301 60

Alert output accumulated pulse setting value

Immediate stop accumulated pulse setting value

Alert output accumulated pulse setting value

Immediate stop accumulated pulse setting value

Accumulated pulse setting value selection 408

Accumulated pulse error detection request 409

Show 11 more labels / short text on this page
restoration request 96 · Feedrate · (absolute value) · Positioning address P1 · Positioning speed V1 · Positioning address P2 · Positioning speed V2 · (maximum value) · (maximum value) · (minimum value) · (minimum value)
Page 276 of the Mitsubishi Electronics QD73A1 user manual — Input/out
Page 276 · click to enlarge
Page 276

Buffer memory address (decimal)

Buffer memory area name

QD73A1 AD70/A1SD70

Measurement start request 410

Reference value write request 411

All the other buffer memory addresses are the same.

(6) External I/O signal comparison

Input/out

Description

put Signal name

QD73A1 AD70/A1SD70

Input Power supply Terminal block None ±15VDC (±14.55 to ±15.45V)

  • Pulse frequency: 200kpulse/s or
  • Pulse frequency: 100kpulse/s or

Phase-A feedback pulse (PULSE A)

Phase-B feedback pulse (PULSE B)

  • ON voltage: 4V or higher
  • ON voltage: 4V or higher

Phase-Z feedback pulse (PULSE Z)

  • OFF voltage: 1V or lower
  • OFF voltage: 1V or lower
  • Pulse frequency: 200kpulse/s or
  • Pulse frequency: 100kpulse/s or

Phase-A feedback pulse (PULSE A)

Phase-B feedback pulse (PULSE B)

  • ON voltage: 2.8V or higher
  • ON voltage: 2.8V or higher

Phase-Z feedback pulse (PULSE Z)

  • OFF voltage: 0.8V or lower
  • OFF voltage: 0.8V or lower

Phase-A feedback pulse (PULSE A)

Pulse frequency1Mpulse/s or less Pulse frequency: 100kpulse/s or less

Phase-B feedback pulse (PULSE B)

Phase-Z feedback pulse (PULSE Z)

All the other external I/O signals are the same.

Show 8 more labels / short text on this page
(Open collector method) · less · less · (TTL method) · less · less · Output · (Differential output method)
Page 277 of the Mitsubishi Electronics QD73A1 user manual — Item Description
Page 277 · click to enlarge
Page 277

APPENDICES

Appendix 4 When Using GX Developer

This section describes the operating procedure of GX Developer.

When using GX Developer, configure the parameter settings and the auto refresh settings with the sequence program.

  • PROGRAMMING ( Page 111, CHAPTER 7)

(1) Applicable software versions

For applicable software versions, refer to the following.

Page 22, Section 2.1 (4)

Appendix 4.1 Operation of GX Developer

Configure the following settings when using GX Developer.

Window name Application Reference

I/O assignment Set the type of the module to be mounted and the I/O signal

range. Page 275, Appendix 4 (1)

A

Configure the switch setting of the intelligent function

module. Page 276, Appendix 4 (2)

(1) I/O assignment

Configure the setting on "I/O assignment" in "PLC parameter".

Parameter [PLC parameter] [I/O assignment]

Appendix 4 When Using GX Developer Appendix 4.1 Operation of GX Developer

Mitsubishi Electronics QD73A1 — (1) I/O assignment diagram (page 277)
Fig. 124 · (1) I/O assignment

Item Description

Type Select "Intelli.".

Model name Enter the model name of the module.

Points The QD73A1 uses two slots. Select "Empty" and "0point" or "16points" for the first slot. Select "Intelli."

and "32points" for the second slot.

StartXY Enter any start I/O number of the QD73A1.

Intelligent function module · switch setting

Page 278 of the Mitsubishi Electronics QD73A1 user manual — (2) Intelligent function module switch setting
Page 278 · click to enlarge
Page 278

(2) Intelligent function module switch setting

Configure the setting on "Switch setting" in "PLC parameter".

Parameter [PLC parameter] [I/O assignment] Click the button.

Mitsubishi Electronics QD73A1 — (2) Intelligent function module switch setting diagram (page 278)
Fig. 125 · (2) Intelligent function module switch setting

Select "HEX.".

b0 Rotation direction setting

0 Positive voltage is output when the positioning address increases.

1 Negative voltage is output when the positioning address increases.

0 0 0 Fixed to 0 (Empty) When a value is set, the value is ignored.

b7 b6 b5 b4 Accumulated pulse setting (unit: pulse)*1

0 -14800 to 14800 (default value)

0 0 0 1 -3700 to 3700 [Selection 1]

0 0 1 0 -7400 to 7400 [Selection 2]

0 0 1 1 -11100 to 11100 [Selection 3]

0 1 0 0 -14800 to 14800 [Selection 4]

0 1 0 1 -37000 to 37000 [Selection 5]

0 1 1 0 -74000 to 74000 [Selection 6]

0 1 1 1 -111000 to 111000 [Selection 7]

1 0 0 0 -148000 to 148000 [Selection 8]

b9 b8 Multiplication setting

0 0 Fixed to 0 (Empty) When a value is set, the value is ignored.

b12 OPR direction setting

0 Reverse direction (address decreasing)

1 Forward direction (address increasing)

b13 OPR method setting

0 Near-point dog method

0 0 Fixed to 0 (Empty) When a value is set, the value is ignored.

Show 8 more labels / short text on this page
Item Setting detail · Bit · b3 b2 b1 · Switch 1 · 1 1 1/2 · b11 b10 · 1 Count method · b15 b14
Page 279 of the Mitsubishi Electronics QD73A1 user manual — A
Page 279 · click to enlarge
Page 279

APPENDICES

Encoder I/F setting and Analog voltage resolution setting

b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0

0

Fixed to 0 Fixed to 0

b1 and b0: Encoder I/F setting 00 or 01: Open collector output 10: TTL output 11: Differential output

b5 and b4: Analog voltage resolution setting 00 or 01: 12-bit resolution 10: 14-bit resolution 11: 16-bit resolution

"00 or 01" means that the setting is valid with either value. When a value is set in b15 to b6, b3, or b2, the value is ignored.

b0 Feedback pulse addition/subtraction setting*2

0 Add when the phase A proceeds 90 degrees than phase B.

1 Subtract when the phase A proceeds 90 degrees than phase B.

A

b3 to b1 -

0 Fixed to 0 (Empty) When a value is set, the value is ignored.

b4 Deviation counter clear setting

0 Clear the deviation counter when Servo READY signal turns off.

1 Do not clear the deviation counter when Servo READY signal turns off.

b15 to b5 -

Appendix 4 When Using GX Developer Appendix 4.1 Operation of GX Developer

0 Fixed to 0 (Empty) When a value is set, the value is ignored.

Zero/gain adjustment mode/Normal mode setting

b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0

0

b15 to b12Zero/gain adjustment mode/Normal mode setting 0000: Normal mode Other than 0000: Zero/gain adjustment mode

When a value is set in b11 to b0, the value is ignored.

Switch 5 Fixed to 0 (Empty) When a value is set, the value is ignored.

*1 When setting values (values in b7 to b4 of Switch 1) are 1111H to 1001H, the setting becomes the same as the one for

the default value (0000H)

*2 The setting becomes enabled only when "1: Negative voltage is output when the positioning address increases." is set for "Rotation direction setting" of Switch 1. When "0: Positive voltage is output when the positioning address increases." is set, the setting value of "Feedback pulse addition/subtraction setting" is ignored.

Show 6 more labels / short text on this page
Item Setting detail · Switch 2 · Bit Setting detail · Switch 3 · Fixed to 0 · Switch 4
Page 280 of the Mitsubishi Electronics QD73A1 user manual — (5) Accumulated pulse
Page 280 · click to enlarge
Page 280

Appendix 5 Terms

(1) Encoder

One of the pulse generators that converts input data into binary data (on and off)

(2) Near-point dog

A switch used in positioning systems, which is placed before the original point of a workpiece. When this switch

turns on, the feedrate is switched to creep speed. Therefore, there is time required for the deceleration from the

federate to the creep speed while this switch is on.

(3) Servo on

A signal that indicates the normal status of a servo amplifier. A servo amplifier is operable only when it is normal

and this signal is on.

(4) Servomotor

A motor that rotates according to a command. This motor is highly responsive, therefore frequent and rapid start

and stop are available with high precision. DC and AC type motors are available as well as high power motors.

Feedback control is available with the included pulse generator that detects the number of rotations.

(5) Accumulated pulse

Pulses that are accumulated in the deviation counter inside the QD73A1. The difference between command

pulses and feedback pulses becomes accumulated pulses.

Accumulated pulses that are proportional to the command pulse frequency are constantly output while the

QD73A1 is operating. The number of accumulated pulses becomes "0" when positioning is completed.

Command pulse frequency f Accumulated pulses

The analog output voltage value from the QD73A1 is proportional to the number of accumulated pulses.

Show 5 more labels / short text on this page
f · t · Gain value · (5 to 10V) · 0 Accumulated pulses
Page 281 of the Mitsubishi Electronics QD73A1 user manual — (11)Workpiece
Page 281 · click to enlarge
Page 281

APPENDICES

(6) Drive unit (servo amplifier)

A generic term for drive units that support analog voltage inputs. The commands that are output from the

QD73A1 are low voltage. This unit is used to amplify the energy and activate a motor. The unit, also called a

servo amplifier, is an accessory on a servomotor.

(7) Pulse generator

A device that generates pulses. For example, by attaching this device on a motor axis, pulses can be generated

by the rotation of the axis.

(8) Feedback pulse

Pulses that are fed back from the encoder to the QD73A1 according to the motor's actual rotation amount

(9) Deviation counter

A counter that counts up and down the difference between the number of command pulses and feedback pulses.

The difference between command pulses and feedback pulses are accumulated in the deviation counter as

"accumulated pulses". The number of accumulated pulses in the deviation counter becomes "0" when positioning

A

is completed.

(10)Zero signal

PG0 of a pulse generator (encoder), that is detected once in one rotation

(11)Workpiece

A generic term for various objects being controlled, including moving objects such as tools

(rotation degree) · Appendix 5 Terms

Page 282 of the Mitsubishi Electronics QD73A1 user manual — Appendix 6 External Dimensions
Page 282 · click to enlarge
Page 282

Appendix 6 External Dimensions

Mitsubishi Electronics QD73A1 — Appendix 6 External Dimensions diagram (page 282)
Fig. 126 · Appendix 6 External Dimensions
(Unitmm)
Page 283 of the Mitsubishi Electronics QD73A1 user manual — APPENDICES
Page 283 · click to enlarge
Page 283

APPENDICES

Memo

A

Appendix 6 External Dimensions

Page 288 of the Mitsubishi Electronics QD73A1 user manual — © 2012 MITSUBISHI ELECTRIC CORPORATION
Page 288 · click to enlarge
Page 288

REVISIONS

*The manual number is given on the bottom left of the back cover.

Print date *Manual number Revision

July 2012 SH(NA)-081075ENG-A First edition

November 2012 SH(NA)-081075ENG-B The accumulated pulse error detection function is added.

September 2014 SH(NA)-081075ENG-C The feedback pulse addition/subtraction setting, deviation counter clear setting, and

deviation counter value monitor are added.

The movement amount after near-point dog ON (absolute value) is added and external

wiring diagrams are corrected.

Japanese manual version SH-081074-F

This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric

Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the

contents noted in this manual.

© 2012 MITSUBISHI ELECTRIC CORPORATION

Page 289 of the Mitsubishi Electronics QD73A1 user manual — 5. Changes in product specifications
Page 289 · click to enlarge
Page 289

WARRANTY

Please confirm the following product warranty details before using this product.

1. Gratis Warranty Term and Gratis Warranty Range

If any faults or defects (hereinafter "Failure") found to be the responsibility of Mitsubishi occurs during use of the product within the gratis warranty term, the product shall be repaired at no cost via the sales representative or Mitsubishi Service Company. However, if repairs are required onsite at domestic or overseas location, expenses to send an engineer will be solely at the customer's discretion. Mitsubishi shall not be held responsible for any re-commissioning, maintenance, or testing on-site that involves replacement of the failed module. [Gratis Warranty Term] The gratis warranty term of the product shall be for one year after the date of purchase or delivery to a designated place. Note that after manufacture and shipment from Mitsubishi, the maximum distribution period shall be six (6) months, and the longest gratis warranty term after manufacturing shall be eighteen (18) months. The gratis warranty term of repair parts shall not exceed the gratis warranty term before repairs. [Gratis Warranty Range] (1) The range shall be limited to normal use within the usage state, usage methods and usage environment, etc., which follow the conditions and precautions, etc., given in the instruction manual, user's manual and caution labels on the product. (2) Even within the gratis warranty term, repairs shall be charged for in the following cases. 1. Failure occurring from inappropriate storage or handling, carelessness or negligence by the user. Failure caused by the user's hardware or software design. 2. Failure caused by unapproved modifications, etc., to the product by the user. 3. When the Mitsubishi product is assembled into a user's device, Failure that could have been avoided if functions or structures, judged as necessary in the legal safety measures the user's device is subject to or as necessary by industry standards, had been provided. 4. Failure that could have been avoided if consumable parts (battery, backlight, fuse, etc.) designated in the instruction manual had been correctly serviced or replaced. 5. Failure caused by external irresistible forces such as fires or abnormal voltages, and Failure caused by force majeure such as earthquakes, lightning, wind and water damage. 6. Failure caused by reasons unpredictable by scientific technology standards at time of shipment from Mitsubishi. 7. Any other failure found not to be the responsibility of Mitsubishi or that admitted not to be so by the user.

2. Onerous repair term after discontinuation of production

(1) Mitsubishi shall accept onerous product repairs for seven (7) years after production of the product is discontinued. Discontinuation of production shall be notified with Mitsubishi Technical Bulletins, etc. (2) Product supply (including repair parts) is not available after production is discontinued.

3. Overseas service

Overseas, repairs shall be accepted by Mitsubishi's local overseas FA Center. Note that the repair conditions at each FA Center may differ.

4. Exclusion of loss in opportunity and secondary loss from warranty liability

Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation of damages caused by any cause found not to be the responsibility of Mitsubishi, loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products, special damages and secondary damages whether foreseeable or not, compensation for accidents, and compensation for damages to products other than Mitsubishi products, replacement by the user, maintenance of on-site equipment, start-up test run and other tasks.

5. Changes in product specifications

The specifications given in the catalogs, manuals or technical documents are subject to change without prior notice.

Page 290 of the Mitsubishi Electronics QD73A1 user manual — SH(NA)-081075ENG-C
Page 290 · click to enlarge
Page 290

Microsoft, Windows, Windows Vista, Windows NT, Windows XP, Windows Server, Visio, Excel, PowerPoint, Visual Basic,

Visual C++, and Access are either registered trademarks or trademarks of Microsoft Corporation in the United States,

Japan, and other countries.

Intel, Pentium, and Celeron are either registered trademarks or trademarks of Intel Corporation in the United States and

other countries.

Ethernet is a registered trademark of Xerox Corp.

All other company names and product names used in this manual are either trademarks or registered trademarks of their

respective companies.

SH(NA)-081075ENG-C

Page 291 of the Mitsubishi Electronics QD73A1 user manual — WARRANTY
Page 291 · click to enlarge
Page 291
Page 291 of the Mitsubishi Electronics QD73A1 user manual — WARRANTY
Page 292 of the Mitsubishi Electronics QD73A1 user manual — SH(NA)-081075ENG-C(1409)MEE MODEL: QD73A1-U-E MODEL CODE: 13JZ69
Page 292 · click to enlarge
Page 292

SH(NA)-081075ENG-C(1409)MEE MODEL: QD73A1-U-E MODEL CODE: 13JZ69

HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN NAGOYA WORKS : 1-14 , YADA-MINAMI 5-CHOME , HIGASHI-KU, NAGOYA , JAPAN

When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission.

Specifications subject to change without notice.

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
ON*3Intentional stop p.232
Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
0pulseAt the input of Speed-position switching command signal (CHANGE) p.200
1When PLC READY signal (Y2D) is turned on p.212
1 p.212
2147483647 pulseWhen PLC READY signal (Y2D) is turned on p.216
0pulse p.216
0When accumulated pulse error detection is requested (When " Cd.18 Accumulated pulse error detection request" is changed from 0 to 1.) p.228
0 p.228
0: Set with pulse p.228
0: No request p.228

Ask about the Mitsubishi Electronics QD73A1

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Mitsubishi Electronics QD73A1

Be the first to ask — other owners or our team will answer.

Original document

Mitsubishi Electronics QD73A1 manual PDF

292 pages·4.3 MB·Universal Remote·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…