Press or to adjust the brightness. * If you do not press any buttons for about 4 seconds, the BRIGHT menu automatically disappears.


1 9 2 0 x 1 0 8 0 LAN
*1 Select the terminal for DVI SELECT. (See page 7.) *2 Select the terminal for HDMI SELECT. (See page 7.) Select the terminal for HDMI AUDIO SELECT which is used for audio input. (See page 7.) *3 Select the terminal for BNC SELECT. (See page 7.)
1 9 2 0 x 1 0 8 0 LAN
STD (Standard) → VIVID → sRGB → STD...
Pressing or displays the VOLUME menu when the menu screen is not displayed.
Press or to adjust the volume of the sound. * If you do not press any buttons for about 4 seconds, the VOLUME menu automatically disappears.

Switching the screen size Even when the screen size is changed, the display may remain the same depending on the input signal.
*: With a monitor of screen resolution 1600 x 1200 or 1920 x 1200, selecting Dot by Dot displays the NORMAL screen.


Video and audio adjustment and settings of various functions are enabled. This section describes how to use the menu items. See pages 6 to 8 for details of each menu items.


1 Name of the menu 2 Input mode 3 An item being selected (highlighted) 4 Screen resolution of input signal, and other data.

For items that have , press , make settings and then press

Menu item details
SHARPNESS Adjusts the sharpness of the image. ADVANCED (AV input) You can adjust more specifi cally. (See page 10.) COLOR MODE Changes the color mode on the screen. The color mode on the screen can also be changed using a remote control unit. (See page 3.) * sRGB is PC input only. See page 3 for details. WHITE BALANCE THRU Displays the input signal level as is. (for PC1/
The menu will differ depending on the input mode.
AUTO (PC3/PC4) The CLOCK, PHASE, H-POS, and V-POS are automatically adjusted. Pressing performs adjustment. Use this automatic adjustment when you use the PC3 input terminal or PC4 input terminals to display a PC screen for the fi rst time or when you change the setting of the PC. (See page 10.) CLOCK (PC3/PC4) Adjusts frequency for sampling clock for applicable video. Adjust when there is fl ickering in the form of vertical stripes. When using the adjustment pattern (see page 10), make adjustments so that no vertical stripe noise appears in it. PHASE (PC3/PC4) Adjusts sampling clock phase for applicable video. Useful when small characters appear with low contrast and/ or there are fl ickers at corners. When using the adjustment pattern (see page 10), make adjustments so that no horizontal stripe noise appears in it.
PC2 only) PRESET Selects the color temperature using PRESET. USER Used for adjusting R-CONTRAST,
G-CONTRAST, and B-CONTRAST respectively. PRESET Selects the color temperature when the WHITE BALANCE is set to PRESET. The setting values are shown for reference. The color temperature of the screen varies over time. This function is not intended to keep the color temperature constant. R-CONTRAST Adjusts red component when the WHITE BALANCE is set to USER. G-CONTRAST Adjusts green component when the WHITE BALANCE is set to USER. B-CONTRAST Adjusts blue component when the WHITE BALANCE is set to USER. COPY TO USER Copies the value set for PRESET to the USER setting. Select “ON” and then press
* Adjustments to PHASE should be made only after CLOCK has been correctly set. H-POS Adjust the horizontal position of the image. V-POS Adjust the vertical position of the image. H-SIZE Adjust the horizontal size of the image. V-SIZE Adjust the vertical size of the image. H-RESOLUTION (PC3/PC4) Sets proper horizontal resolution when the resolution of input signals is not recognized properly. (Adjustment may be impossible with some signals.) V-RESOLUTION (PC3/PC4) Sets proper vertical resolution when the resolution of input signals is not recognized properly. (Adjustment may be impossible with some signals.) RESET Resets the values of the SCREEN menu items to the factory preset values. Select “ON” and then press
MENU .
GAMMA Select a gamma value. RESET Resets the values of the PICTURE menu items to the factory preset values. Select “ON” and then press
MENU .
MENU .
Adjusts the volume of treble-level sound.
PICTURE
Adjusts the volume of bass-level sound.
AUTO (PC3/PC4) The CONTRAST and BLACK LEVEL are automatically adjusted. Pressing performs adjustment.
Adjusts the balance of the audio sound between right and left. RESET
CONTRAST Adjusts the brightness of the image. BLACK LEVEL Adjusts the entire brightness of the video signals. TINT Adjusts the hue. Selecting + changes the color towards green, and selecting - changes it towards magenta. COLORS Adjusts the color intensity.
Resets the values of the AUDIO menu items to the factory preset values. Select “ON” and then press
MENU .
OSD H-POSITION Adjusts the horizontal display position of menu screen. OSD V-POSITION Adjusts the vertical display position of menu screen.

SCREEN MOTION Residual images are reduced by moving the screen. PATTERN 1 The whole screen moves vertically and
ID No. SET Assigns ID numbers to monitors connected in a daisy chain (see page 13), using RS-232 cables. The numbers 1 to 255 are available for ID numbers. If “0” is set, the system regards this as the state where no ID number is set. LAN SETUP Confi gures the settings to control the monitor from the computer via LAN. (See page 21.)
horizontally. PATTERN 2 A black screen spreads from the bottom of
the screen and then shrinks to the bottom of the screen. If the monitor is installed in the vertical orientation, a black screen spreads from the left end of the screen and then shrinks to the left end of the screen. PATTERN 3 A black bar moves from the left end to the right
end of the screen. If the monitor is installed in the vertical orientation, a black bar moves from the top to the bottom of the screen. PATTERN 4 Black screens appear from both the top and
Set the date and time. Press or to select the date and time, and press or to change the numerical values. Set the date in “Year/Month/Day” order. Set the time on a 24-hour basis. SCHEDULE (See page 9.) You can set the time to switch the monitor on and off. INPUT SELECT DVI SELECT Selects the input mode to be used. BNC SELECT Selects the input mode to be used. HDMI SELECT ... Selects the input mode to be used. HDMI AUDIO SELECT .. Selects a terminal to which audio signals
bottom of the screen, and the displayed image is compressed into the central fi eld. If the monitor is installed in the vertical orientation, the screen is compressed from the left and right ends.
MOTION TIME 1 Specify a time period (operating interval) until SCREEN MOTION starts. MOTION TIME 2 Specify a time period during which SCREEN MOTION operates (time period during which the screen will move). MONITOR Select the installation direction of the monitor. LANDSCAPE Horizontal orientation PORTRAIT Vertical orientation LANGUAGE Sets the display language for the menu screen. HDMI AUTO VIEW When ON is selected, the screen size is adjusted automatically according to the screen size control signal included in the video signal input from the AV2 input terminal. POWER ON DELAY You can delay the screen display after the monitor is turned on. The period can be set up to 60 seconds in units of one second. When this function is activated, the power LED fl ashes (at approx. 1 second interval) in orange. This function is disabled when 0 is specifi ed. STANDBY MODE When STANDARD is selected, startup time from standby mode is reduced. Note, however that, more power will be consumed in standby mode. When LOW POWER is selected, current consumption is reduced while the monitor is in standby mode. Note, however, that the startup time from standby mode becomes longer. Also, certain RS-232C commands cannot be used in standby mode. (See page 16.) RS-232C/LAN SELECT Selects the method with which to control the monitor from the computer. RS-232C/LAN COMMAND Set the return value for the RS-232C command. Normally, you do not need to change this setting from NORMAL. NORMAL The end code of the return value is CR+LF. MODE1 The end code of the return value is CR only. MODE2 The length of the return value is fi xed to 4
are input in PC2/AV2 mode. AUDIO OUTPUT Sets the volume of sound output from the PC/AV audio output terminals. VARIABLE You can adjust the volume using VOLUME. FIXED Fixes the sounds. INPUT SIGNAL (PC3/PC4) If a computer connected to the PC3/PC4 input terminal outputs any of the following resolutions, make a selection from the following options. 480 LINES AUTO, 640x480 or 848x480 768 LINES AUTO, 1024x768, 1280x768, or 1360x768 1050 LINES 1400x1050 or 1680x1050 SCAN MODE (AV input) Sets the scan mode used for AV mode input. MODE1 Over-scan display MODE2 Under-scan display MODE3 Under-scan display when the input signal
is 1080i/p. Otherwise, over-scan display * Even when MODE1 is selected, under-scan display is used when the input signal is 1080i/p and the screen size is Dot by Dot.
SELF ADJUST On a PC3/PC4 screen, specify whether to perform screen adjustment automatically or not. When ON is selected, the screen is automatically adjusted when its resolution is 800 x 600 or higher and the timing of input signals changes. “ADJUSTING” appears on the screen during the adjustment. POWER MANAGEMENT POWER MANAGEMENT determines whether or not to switch modes from no signal to the input signal standby mode when the PC screen is displayed. AUTO INPUT CHANGE Specify whether to change inputs automatically. When ON is selected and no signal is present in the selected input mode, AUTO INPUT CHANGE automatically changes the selected mode to another mode where a video signal is present. When video signals exist in multiple input modes, the switching priority is as follows: PC1, PC2, PC3, PC4, AV1, AV2, AV3, AV4 and AV5. (Input mode switching may take 15 seconds or more, depending on the connected equipment. Input signals may not be detected properly and a priority may change, depending on the connected equipment or video signals.)
digits. The end code is CR only. When the return value has 1 to 3 digits, the empty digit(s) from the left is fi lled with a one-byte space(s).

COLOR SYSTEM (AV4/AV5) Select the color system of the AV equipment which is connected to AV4 and AV5 input terminal. (AUTO / PAL / PAL-60 / SECAM / NTSC3.58 / NTSC4.43) When AUTO is selected, the color system is automatically set according to the input signal.
Dual screen display You can display the screens of the PC input signal and AV input signal simultaneously. Set this function with “PIP MODES” in the PIP/PbyP menu.
ENLARGE H Sets the number of screen splits (number of monitors) in the horizontal direction used for the enlargement. (See page 9.) ENLARGE V Sets the number of screen splits (number of monitors) in the vertical direction used for the enlargement. (See page 9.) ENLARGE-POS H / ENLARGE-POS V Specify the split screen to be displayed when the enlargement function is used. (See page 9.) BEZEL H / BEZEL V Sets the frame width of the display when the enlargement function is used. H-POS Adjust the horizontal position of the enlarged screen. V-POS Adjust the vertical position of the enlarged screen.
PIP MODES Sets the display method. OFF Displays one screen. PIP Displays a sub screen inside a main screen. PbyP Displays a main screen and a sub screen in a line. PbyP2 Displays a main screen which measures 1280 pixels
* The currently selected input signal is displayed on the main screen. * You cannot simultaneously display the screens of signals of the same type, such as two types of PC input signals or two types of AV input signals. * The dual screen display cannot be used with the combination of PC1 and AV2 or of AV1 and PC2.
in the longest direction and a sub screen in a line. PIP SIZE Sets the size of the sub screen in PIP mode. PIP H-POS
Adjusts the horizontal position of the sub screen in PIP mode. PIP V-POS Adjusts the vertical position of the sub screen in PIP mode. PIP BLEND In PIP mode, use this menu item to display the sub screen transparently. PIP SOURCE Selects the input signal of the sub screen in PIP, PbyP, or PbyP2 mode. SOUND CHANGE Sets the sound which is output in PIP, PbyP, or PbyP2 mode. If the main screen is displayed as a full screen by the AUTO OFF function, the sound for the main screen is output even when the sound for the sub screen is specifi ed. MAIN POS Sets the position of the main screen in PbyP or PbyP2 mode. PbyP2 POS Sets the position of the sub screen in PbyP2 mode. AUTO OFF Sets the display method when no signals for the sub screen are input in PIP, PbyP, or PbyP2 mode. MANUAL Displays a main screen and a black sub screen. AUTO Displays the main screen as a full screen.

Enlarge
SCHEDULE You can set the time to switch the monitor on and off. Set this function with “SCHEDULE” in the OPTION menu. (See page 7.)

Setting procedure In the ENLARGE menu, set ENLARGE H/V and ENLARGE-POS H/V. (See page 8.) 1. Set the number of monitors aligned in the horizontal direction in ENLARGE H. 2. Set the number of monitors aligned in the vertical direction in ENLARGE V. 3. Set the section of the separated image to be displayed on each monitor in ENLARGE-POS H and ENLARGE-POS V. In horizontal orientation
OK…[MENU] 1 9 2 0 x 1 0 8 0 V: 60 Hz H: 66.3 kHz

Press or to select items, and press or to change the setting.
(1) • : SCHEDULE effective -: SCHEDULE not effective (2) POWER ON : Switches the monitor on at the specifi ed time. OFF : Switches the monitor off at the specifi ed time and puts

the monitor in standby mode. (3) DAY OF THE WEEK Specifi es the day of the week to execute the SCHEDULE. ONLY ONCE:
Executes the SCHEDULE once on the specifi ed day. Specify the day of the week to execute the SCHEDULE. EVERY WEEK:
Executes the SCHEDULE on the specifi ed day of the week every week. Specify the day of the week to execute the SCHEDULE. Periodic setting such as “Monday through Friday” is also possible. EVERY DAY:
Executes the SCHEDULE every day regardless of the day of the week. (4) TIME Specifi es the time to execute the SCHEDULE. Set the time on a 24-hour basis.
* The numbers in parentheses are the setting values in (ENLARGE-POS H, ENLARGE-POS V) format.


(5) INPUT Specifi es the input mode at power-on. When not specifying, the screen at the previous power-off appears. Input modes displayed on “PC1/AV1” depend on DVI SELECT settings. Input modes displayed on “PC2/AV2” depend on HDMI SELECT settings. Input modes displayed on “PC4/AV3” depend on BNC SELECT settings.
Automatic adjustment When you use the PC3 input terminal or PC4 input terminals to display a PC screen for the fi rst time, or when you change the setting of the PC, use the automatic screen adjustment. 1. Switch the input to PC3 or to PC4 and display the adjustment pattern. (See the description below.) 2. Press MENU and use or to display the SCREEN menu.
Screen display for adjustment Before making adjustments in the SCREEN menu or PICTURE menu, display an image to brighten the entire screen. If you are using a Windows PC, use the adjustment pattern on the supplied CD-ROM.
FLESH TONE Adjust the hue control. 3D-NR Reduce the noise of playback images on video. Setting a higher level reduces more noise. However, it may cause blurring on an image. MPEG-NR Reduce block noise caused by digital compression. 3D-Y/C (AV5) Specify whether to perform 3-dimension Y/C separation. If dot interference or cross-color is occurring in fast-motion scenes, selecting “OFF” may improve the image quality. C.M.S.-HUE Adjusts color tone with 6 colors of R (red), Y (yellow), G (green), C (cyan), B (blue), and M (magenta). C.M.S.-SATURATION Adjusts color vividness with 6 colors of R (red), Y (yellow), G (green), C (cyan), B (blue), and M (magenta). C.M.S.-VALUE Adjusts color brightness with 6 colors of R (red), Y (yellow), G (green), C (cyan), B (blue), and M (magenta).
Opening the adjustment pattern 1. Load the supplied CD-ROM into the computer’s CD- ROM drive. 2. Open the CD-ROM in [My Computer]. 3. Double-click [Adj_uty.exe]. The adjustment pattern will appear. Adjust the screen automatically or manually.

You can return the settings to their factory-preset values and restrict operations.
TEMPERATURE ALERT Selects the notifi cation method for an abnormal temperature. OFF Do not notify about an abnormal
, , and in that order.
temperature. OSD & LED .. When an abnormal temperature is
detected, the power LED fl ashes in red and green alternately and the screen displays a message: TEMPERATURE. LED When an abnormal temperature is
ADJUSTMENT LOCK
OFF
RS-232C/LAN
UNLOCKED
detected, the power LED fl ashes in red and green alternately. STATUS ALERT Selects the notifi cation method for a hardware error. OFF Do not notify about the error. OSD & LED .. When a hardware error is detected, the
ON
LED
ON
TEMPERATURE ALERT
LED
STATUS ALERT
OFF
END … [MENU]
power LED fl ashes in red and the screen displays a message: STATUS [xxxx]. LED When a hardware error is detected, the
ALL RESET Resets the settings to the factory default settings. Press , select the resetting method, and then press
power LED fl ashes in red.
MENU . After initialization, turn the main power switch off and then back on. ALL RESET1 Resets all the settings to the factory
default settings. ALL RESET2 Returns all settings to the factory default
settings except for the following items: LAN SETUP, RS-232C/LAN SELECT, NETWORK, MAIL, and SERVICE & SUPPORT (See page 7, and pages 25 to 28.) ADJUSTMENT LOCK You can disable operations on the monitor and the remote control unit that use buttons. OFF ...Enables operation. 1 Disables all operations other than turning power on/off and FUNCTION. 2 Only the FUNCTION operation is enabled. Disables all operations other than FUNCTION (not even power on/off). RS-232C/LAN Specifi es whether to allow control via RS-232C or LAN (see pages 12 and 21). OSD DISPLAY Hides/shows menus. The FUNCTION screen cannot be hidden. LED Specifi es whether to light power LEDs.


You can control this monitor from a PC via RS-232C (COM port) on the PC. You can also connect multiple monitors via a daisy chain by using a PC. By assigning ID numbers to each monitor (see page 13), you can make input mode selection/adjustment or can check the status of a specifi c monitor.
Set the RS-232C communication settings on the PC to match the monitor’s communication settings as follows:
Command format When a command is sent from the PC to the monitor, the monitor operates according to the received command and sends a response message to the PC.
One-to-one connection with a PC Connect with RS-232 straight cable between the PC’s COM port (RS-232C connector) and the RS-232C input terminal on the monitor.

Parameter field (4 character string comprised of:
(4 prescribed alphanumerical characters)
0-9, +, -, space, ?)
* Be sure to input 4 characters for the parameter. Pad with spaces (“ ”) if necessary. (“ ” is a return code (0DH, 0AH or 0DH)) Wrong : VOLM30 Right : VOLM 30
RS-232 straight cable (commercially available)
When inputting a negative value, specify a numerical value in three digits.
Connect with RS-232 straight cable between the PC’s COM port (RS-232C connector) and the RS-232C input terminal on the fi rst monitor. Next, connect RS-232 straight cable to the fi rst monitor’s RS-232C output terminal and to the second monitor’s RS-232C input terminal. Connect in the same way to the third and subsequent monitors. Up to 25 monitors can be connected. (Depending on the length of the cable used and the surrounding environment.)
Do not use spaces for MPOS, DATE, and SC01 through SC08. Specify parameters using a specifi ed number of characters.
If a command has “R” listed for “DIRECTION” in the “RS-232C command table” on page 16, the current value can be returned by using “?” as the parameter.
First monitor Second monitor


VOLM ? ← From PC to monitor (How much is current volume setting?).
30 ← From monitor to PC (Current volume setting: 30).
* If an ID number (see page 13) has been assigned (For example, ID number = 1).
RS-232 straight cables (commercially available)
Return code · Command field · To COM port

Communication interval
O K Return code (0DH, 0AH)
A response is returned after a command is executed.
* If an ID number has been assigned
Return code (0DH, 0AH)
Space (20H)
O K SPC 0 0 1
Interval of 100 ms or more
ID number of responding monitor
R R E Return code (0DH, 0AH)
* If an ID number has been assigned
Space (20H) Return code (0DH, 0AH)
Advanced operation This section explains commands for daisy chain connection. The basic communication procedure is the same as in the “One-to-one connection with a PC” section.
ID numbers You can assign a unique ID number to each monitor (see page 7). This allows you to control a particular monitor in a daisy chain of monitors. You can assign ID numbers either from the menu screen (using the remote control) or from the PC using RS-232 cable.
I W T A Return code (0DH, 0AH)
If monitors are connected as shown above, you can execute commands like “Set the volume of the monitor with ID 4 to 20”.
When the following commands are used, “WAIT” is returned. In this case, a value will be returned if you wait a while. Do not send any command during this period. No ID number is attached to WAIT response.
When controlling monitors linked in a daisy chain by designating ID numbers, you should basically avoid any duplication of ID numbers. ID numbers do not have to be assigned in ascending order starting from the PC. They can also be connected as shown below.
When control via RS-232C is locked (to prevent use) using the operation lock function (see page 11)
E C D K O L Return code (0DH, 0AH)
U N S E L E C T E D
Return code (0DH, 0AH)
ID number · [Example] · [Example]

Commands for ID control The command examples shown on this page assume the following connection and ID number set up.
IDLK The parameter of this command sets the ID
number of the monitor. The monitor is subject to all subsequent commands.
Example:
IDLK0002 ← Following commands are for the monitor with ID number: 2.
WAIT ← Searching for monitor with ID number: 2
IDST A monitor receiving this command sets its own ID
OK 002 ← Found monitor with ID number: 2
number in the parameter fi eld.
VOLM0030 ← Sets volume of monitor with ID number: 2 to 30.*
Example:
OK 001 ← The ID number of this monitor is set to 1.
VOLM0020 ← Sets volume of monitor with ID number: 2 to 20.*
You can automatically assign ID numbers by using the IDST command with the Repeater control (see “Repeater control” on page 15). For example, using the command “IDST001+” automatically sets the ID numbers, as shown below.
IDLK0000 ← Canceling fi xed ID number setting
WAIT ← Canceling IDLK
OK 002 ← Cancelation complete
The volume of the monitor with ID number: 1 (the one directly connected to the PC) is set to 10. (IDLK is canceled.)
* The IDLK command remains effective until it is canceled, or power is shut off.
IDST001 + ← ID setting command with repeater control
IDCK Provides screen display of the ID number currently
OK 001 ← “OK” response from ID number: 1
assigned to a monitor, and the ID number currently set for IDLK (if any).
OK 002 ← “OK” response from ID number: 2
OK 003 ← “OK” response from ID number: 3
Example:
OK 004 ← “OK” response from ID number: 4 (End)
IDCK0000 ← (Parameter has no meaning.)
IDSL The parameter of this command sets the ID number
of the monitor. The monitor is subject to the next command.
Returned response. The ID number is also displayed on the monitor screen.
Example:
IDCK000 + ← Repeater control. (If a command is used with repeater control, ID designation using IDSL or IDLK is canceled.) WAIT
IDSL0002 ← The next command is for the monitor with ID number: 2.
WAIT ← Searching for monitor with ID number: 2
OK 002 ← Found monitor with ID number: 2
VOLM0030 ← Sets volume of monitor with ID number: 2 to 30.
OK 002 ← OK response from monitor with ID number: 2
VOLM0020 ← Sets volume to 20.
The volume of the monitor with ID number: 1 (the one directly connected to the PC) is set to 20.*
* The IDSL command is effective only once, for the immediately succeeding command.

Repeater control This system has a function to allow setting of multiple monitors connected in a daisy chain using a single command. This function is called repeater control. You can use Repeater control function without assigning ID numbers.
Set 2 Set 3 Set 4
* If monitors are connected as shown above, you can execute a command like “Set all monitors’ input settings to PC1 DVI-D”.
Repeater control command Repeater control is achieved by setting the FOURTH CHARACTER of the parameter to “+”.
Example:
VOLM030 + ← Sets volume of all monitors to 30.
In repeater control, responses are returned by all the connected monitors. If you want to determine that a value has been returned by a specifi c set, assign ID numbers to each monitor in advance. When some monitors do not return their responses, the probable cause is that the monitors could not receive the command or command processing is not complete. Do not send a new command.
WAIT
OK 001
OK 002
OK 003
OK 004 ← If 4 monitors are connected in a chain, reliable operation can be ensured by sending a new command only after a reply has been returned by 4th (last) monitor.
Repeater control can also be used for reading settings.
Example:
WAIT
Volume settings for all monitors are returned. 20 002
[Example] · Set 1


Command: Command fi eld (See page 12.) Direction: W When the “Parameter” is set in the parameter fi eld (see page 12), the command functions as described
under “Control/Response Contents”. R The returned value indicated under “Reply” can be obtained by setting “”, “ ?” or “+” (repeater control) in the parameter fi eld (see page 12). Parameter: Parameter fi eld (See page 12.) Reply: Response (Returned value) *: “A” indicates a command which can be used in power standby mode regardless of the STANDBY MODE setting. “B” indicates command which can be used in power standby mode when STANDBY MODE is set to STANDARD. (It cannot be used in the power standby mode when LOW POWER is selected.) “–” indicates a command which cannot be used in power standby mode.

INPUT MODE SELECTION INPS W 0 Toggle change for input mode. Terminals not selected in DVI SELECT/ BNC SELECT/HDMI SELECT cannot be selected.
1 PC1 DVI-D “ERR” when AV1 DVI-D is selected for DVI SELECT.
3 AV3 COMPONENT “ERR” when PC4 RGB is selected for BNC SELECT.
6 PC4 RGB “ERR” when AV3 COMPONENT is selected for BNC SELECT.
7 AV1 DVI-D “ERR” when PC1 DVI-D is selected for DVI SELECT.
9 AV2 HDMI “ERR” when PC2 HDMI is selected for HDMI SELECT.
10 PC2 HDMI “ERR” when AV2 HDMI is selected for HDMI SELECT.

AUTO ASNC W 1 When the input mode is PC3, PC4.
CLOCK CLCK WR 0-1200 0-1200 When the input mode is PC3, PC4. Varies depending on the signal.
PHASE PHSE WR 0-63 0-63 When the input mode is PC3, PC4.
HPOS WR 0-100 0-100 0-800 on PC3/PC4. Varies depending on the signal.
VPOS WR 0-100 0-100 0-200 on PC3/PC4. Varies depending on the signal.
RESOLUTION L-DIRECTION RES HRES WR 300-1920 300-1920 When the input mode is PC3, PC4. Only even numbers are valid for parameters. Varies depending on the signal. S-DIRECTION RES VRES WR 200-1200 200-1200


AUTO AGIN W 1 When the input mode is PC3, PC4. -
BLACK LEVEL BLVL WR 0-60 0-60 0-127 on PC3/PC4.
FLESH TONE FLES WR 0-2 0-2 0: OFF, 1: LOW, 2: HIGH
B 3D-NR TDNR WR 0-2 0-2 0: OFF, 1: LOW, 2: HIGH
MPEG-NR MPNR WR 0-1 0-1 0: OFF, 1: ON
3D-Y/C YCSP WR 0-1 0-1 0: OFF, 1: ON (When the input mode is AV5)
3 3 sRGB (When the input mode is PC)
WHITE BALANCE THRU CTMP WR 0 0 When the input mode is PC1/PC2.
R-CONTRAST CRTR WR 0-512 0-512 “ERR” when CTMP is not set to 99.
COPY TO USER CPTU W 0 Copies a preset value to the user setting. -
GAMMA GAMM WR 0-2 0-2 0: 1.8, 1: 2.2, 2: 2.4 B


Function Command Direction Parameter Reply Control/Response contents *
OSD H-POSITION OSDH WR 0-100 0-100 B OSD V-POSITION OSDV WR 0-100 0-100
SCREEN MOTION SCSV WR 0-4 0-4 0: OFF, 1-4: PATTERN1-4 B
MOTION TIME 2 PATTERN1 MINT WR 10-990 10-990 Per 10 seconds
B PATTERN2-4 MINT WR 5-20 5-20 Per second
MONITOR STDR WR 0-1 0-1 0: LANDSCAPE, 1: PORTRAIT B
1 1 DEUTSCH
2 2 FRANÇAIS
3 3 ITALIANO
B
4 4 ESPAÑOL
5 5 РУССКИЙ
HDMI AUTO VIEW HDAW WR 0-1 0-1 0: OFF, 1: ON B
Power On Delay PWOD WR 0 0 OFF
STANDBY MODE STBM WR 0-1 0-1 0: STANDARD, 1: LOW POWER B
RS-232C/LAN SELECT CTLS WR 0-1 0-1 0 : RS-232C 1 : LAN B
RS-232C/LAN COMMAND CMDM WR 0-2 0-2 0 : NORMAL, 1 : MODE1, 2 : MODE2 B
ID NUMBER ID NO. SETTING IDST W 0-255 Sets the monitor’s ID number. (“0” means “no ID number”.)
R 0-255 Returns the monitor’s ID number.
IDSL W 1-255 Sets a monitor ID number. This ID number is only effective for the command immediately after this command.
0 Clears the ID number if one has been designated.
ID NO. SETTING (SUBSEQUENT)
IDLK W 1-255 Sets a monitor ID number. This ID number is effective for the next and all subsequent commands after this command.
0 Clears the ID number if one has been designated.
ID CHECK IDCK W 0 ID : xxx IDLK : yyy
Displays monitor’s own ID number and the selected ID number on the screen. B
Function Command Direction Parameter Reply Control/Response contents *
DATE/TIME SETTING DATE WR AABBCCDDEE AABBCCDDEE AA: Year, BB: Month, CC: Day, DD: Time, EE: Minute B
WR ABCDEFFGGH ABCDEFFGGH Schedule of a specifi ed number
A: Schedule 0= Not effective, 1 = Effective B: Power 0 = OFF, 1 = ON C: Day of the week 1 0 = Only once, 1 = Every week, 2 = Every day D: Day of the week 2 0 = Sunday, 1 = Monday through 6 = Saturday, 9 = Not exist E: Day of the week 3 0 = Sunday, 1 = Monday through 6 = Saturday, 9 = Not exist F: Time 00-23 G: Minute 00-59 H: Input 0 = Not specifi ed, 1 = PC1/AV1, 2 = PC3, 3 = PC4/AV3, 4 = AV5, 5 = AV4, 6 = PC2/AV2
INPUT SELECT DVI SELECT DVSL WR 0-1 0-1 0: PC1 DVI-D, 1: AV1 DVI-D B
BNC SELECT BNSL WR 0-1 0-1 0: PC4 RGB, 1: AV3 COMPONENT B
HDMI SELECT HDSL WR 0-1 0-1 0: PC2 HDMI, 1: AV2 HDMI B
HDMI AUDIO SELECT HMDA WR 0-1 0-1 0: DIGITAL, 1: ANALOG B
AUDIO OUTPUT AOUT WR 0-1 0-1 0: VARIABLE, 1: FIXED B
RESOLUTION CHECK PXCK R - Returns current resolution in the form of hhh, vvv.
PXSL WR 1 1 768) 1360 x 768
2 2 768) 1280 x 768
3 3 768) 1024 x 768
5 5 480) 848 x 480
6 6 480) 640 x 480
7 7 1050) 1680 x 1050
8 8 1050) 1400 x 1050
10 10 480) AUTO
INPUT RESOLUTION (AV) RESOLUTION CHECK RESO R - 480i, 480p, 1080i, 720p, 1080p, VGA , etc. -
SCAN MODE SCAN WR 0-2 0-2 0: MODE1, 1: MODE2, 2: MODE3 (When the input mode is AV) B
SELF ADJUST AADJ WR 0-1 0-1 0: OFF, 1: ON B
POWER MANAGEMENT PMNG WR 0-1 0-1 0: OFF, 1: ON B
AUTO INPUT CHANGE AINC WR 0-1 0-1 0: OFF, 1: ON B
COLOR SYSTEM CSYS WR 0-5 0-5 0: AUTO, 1: PAL, 2: PAL-60, 3: SECAM, 4: NTSC3.58, 5: NTSC4.43 B

Function Command Direction Parameter Reply Control/Response contents *
ENLARGE MODE EMAG WR 0-4 0-4 0: OFF, 1: 2 x 2, 2: 3 x 3, 3: 4 x 4, 4: 5 x 5
EMHV WR 11-55 11-55 1 x 1 (OFF) to 5 x 5 (“m x n” is expressed as “mn”, where m and n are the numbers of monitors specifi ed for the longest direction and the shortest direction respectively.)
BEZH WR 0-100 0-100
WIDTH OF THE LONGER SIDE
BEZV WR 0-100 0-100
IMAGE POSITION (M x N) EPHV WR 11-55 11-55 Specify values in the order of ENLARGE-POS LD/ENLARGE-POS SD.
IMAGE POSITION (2 x 2) EPOS WR 0-3 0-3 See the description below.
IMAGE POSITION (3 x 3) EPOS WR 0-8 0-8
IMAGE POSITION (4 x 4) EPOS WR 0-15 0-15
IMAGE POSITION (5 x 5) EPOS WR 0-24 0-24
THE LONGEST DIRECTION
EPSH WR -999-999 -999-999 The setting range depends on the ENLARGE MODE setting and the IMAGE POSITION.
EPSV WR -999-999 -999-999
ENLARGE/IMAGE POSITION SETTING ESTG WR XXYY XXYY XX: ENLARGE MODE (Same as EMAG), YY: IMAGE POSITION (Same as EPOS)
2 x 2 4 x 4 5 x 5 3 x 3
12 13 14 15
2 x 2 4 x 4 5 x 5 3 x 3
4 9 14 19 24


PIP MODES MWIN WR 0-3 0-3 0: OFF, 1: PIP, 2: PbyP, 3: PbyP2 B
PIP POS LD+SD BATCH MPOS W 0-100,0-100 Specify the position in MPOSxxxyyy format. (xxx: Longer side, yyy: Shorter side position) B
R 0-100,0-100 Returns a response in (xxx,yyy) format. (xxx: Longer side, yyy: Shorter side position) B
SOUND CHANGE MWAD WR 1-2 1-2 1: MAIN, 2: SUB B
MAIN POS (Main screen) MWPP WR 0-1 0-1 0: POS1, 1: POS2 B
PbyP2 POS (Sub screen) MW2P WR 0-2 0-2 0: POS1, 1: POS2, 2: POS3 B
AUTO OFF MOFF WR 0-1 0-1 0: MANUAL, 1: AUTO B

ALL RESET RSET W 0-1 0: ALL RESET 1, 1: ALL RESET 2 -
ADJUSTMENT LOCK ALCK WR 0-2 0-2 0: OFF B
OSD DISPLAY LOSD WR 0-1 0-1 0: ON, 1: OFF B
LED OFLD WR 0-1 0-1 0: ON, 1: OFF B
TEMPERATURE ALERT TALT WR 0-2 0-2 0: OFF, 1: OSD & LED, 2: LED B
STATUS ALERT SALT WR 0-2 0-2 0: OFF, 1: OSD & LED, 2: LED B

SCREEN SIZE (PC) WIDE WR 1-5 1-5 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM1, 5: ZOOM2 B
SCREEN SIZE (AV) WIDE WR 1-5 1-5 1: WIDE, 2: ZOOM1, 3: ZOOM2, 4: NORMAL, 5: Dot by Dot B
MUTE MUTE WR 0-1 0-1 0: OFF, 1: ON -
2 Internal temperature abnormal (Temperature is normal now, but it was abnormal during operation.)
3 Internal temperature abnormal (Brightness of the backlight decreases.)
TEMPERATURE ACQUISITION ERRT R Value Temperature at temperature sensors 1 through 3 are returned in the following forms: [Sensor 1], [Sensor 2], [Sensor 3] Indicates a temperature sensor abnormality when “126” is returned.
CAUSE OF LAST STANDBY MODE STCA W 0 Initialization
2 Main power “OFF” by the main power switch
4 Waiting mode by No Signal (Incl: VESA DPMS/DMPM)


Your monitor can be connected to a LAN allowing you to control it from a PC on the LAN. You can also confi gure the monitor to send e-mail notifi cation when it has a problem. The connection requires a commercially available LAN cable (UTP cable, Category 5, straight through).
Set the monitor’s IP address and subnet mask to match the settings of your LAN. These settings can be made on either the monitor or a PC connected to the monitor. The settings depend on the confi guration of your LAN. Ask your LAN administrator for details.
To set on the monitor Set RS-232C/LAN SELECT on the SETUP menu to LAN, and then set the LAN SETUP options. (See page 7.) After setting each item, select SET and press
MENU .
DHCP CLIENT If your LAN has a DHCP server and you wish to obtain an address automatically, change this setting to ON. To set the address manually, set this to OFF. IP ADDRESS If the DHCP CLIENT is set to OFF, specify an IP address. Press or to select items, and press or to change the values. SUBNET MASK If the DHCP CLIENT is set to OFF, specify the subnet mask. Press or to select items, and press or to change the values. DEFAULT GATEWAY If the DHCP CLIENT is set to OFF, specify the default gateway. If you are not using a gateway, specify “0.0.0.0”. Press or to select items, and press or to change the values. RESET Resets the values of the LAN settings to the factory preset values. Select ON and then press
LAN cable (commercially available, straight)
MENU .
Network (LAN) · LAN terminal · Hub

To set from a PC When the monitor is connected to a PC, LAN settings can be confi gured via PC.
Set up process (1) Connect your monitor to a PC (2) Specify the PC’s IP address (3) Confi gure the monitor’s LAN settings

(1) Connecting your monitor to a PC Connect a commercially available crossover LAN cable (UPT cable, Category 5) to the LAN port on the PC and this monitor.

(3) Confi guring the monitor’s LAN settings Access the monitor using Internet Explorer.
(2) Specifying the PC’s IP address To confi gure the monitor’s LAN settings, you must temporarily change the settings on the PC. This explanation is based on Windows XP. 1. Log on to the PC with an administrator account. 2. Click [Start], and then click “Control Panel”. 3. Click “Network and Internet Connections”, and then click “Network Connections”. If you are using the classic display style, double-click on “Network Connections”. 4. Right click on “Local Area Connection” and from the menu, click “Properties”. 5. Click “Internet Protocol (TCP/IP)”, and then click “Properties”. 6. Make a note of the current IP address, subnet mask, and default gateway settings. Make sure you write this information now as you will be changing the IP address, subnet mask, and default gateway settings back to these settings afterwards.
You will be prompted to enter a user name and password. 4. Leave the user name and password boxes blank and click [OK].
Controlling the monitor · PC operation


Basic operation You use Internet Explorer on a PC on the LAN to control the monitor. 1. Launch Internet Explorer on the PC. 2. In the “Address” box, type “http://” followed by your monitor’s IP address followed by “/”, then press the Enter key.
When prompted to enter a user name and password, type the user name and password that you specifi ed in the security settings (see page 25), and click [OK]. If you did not make any security settings, leave the spaces blank and click on [OK]. 3. You can check, control, and change the monitor’s status and settings by clicking the menu items on the left side of the screen.


DHCP CLIENT If your LAN has a DHCP server and you wish to obtain an address automatically, change this setting to “ON”. To set the address manually, set this to “OFF”. IP ADDRESS If the DHCP CLIENT is set to “OFF”, specify an IP address. SUBNET MASK If the DHCP CLIENT is set to “OFF”, specify the subnet mask. DEFAULT GATEWAY If the DHCP CLIENT is set to “OFF”, specify the default gateway. If you are not using a default gateway, specify “0.0.0.0”.

INFORMATION Information about this monitor appears.
You can adjust these settings which are also available on the monitor’s menu.

INPUT
SIZE ) on the remote control unit. (See page 3.)


NETWORK (LAN SETUP) This screen allows you to set the settings necessary when the monitor is connected to a LAN.
NETWORK (SECURITY) This screen allows you to specify the security-related settings.


USER NAME / PASSWORD Sets up a user name and password to restrict access to this monitor. After entering a user name and password, click [Apply]. ACCEPT IP ADDRESS You can limit access to this monitor by registering IP addresses of PCs that should have access. To limit access, specify the option “From only specifi c IP addresses”. Otherwise, to allow access from any PC, specify “All IP Addresses”. IP ADDRESS 1 to 3 If “ACCEPT IP ADDRESS” is set to “From only specifi c IP addresses”, enter the IP addresses that you want to allow.
DHCP CLIENT If your LAN has a DHCP server and you wish to obtain an address automatically, change this setting to “ON”. To set the address manually, set this to “OFF”. IP ADDRESS If the DHCP CLIENT is set to “OFF”, specify an IP address. SUBNET MASK If the DHCP CLIENT is set to “OFF”, specify the subnet mask. DEFAULT GATEWAY If the DHCP CLIENT is set to “OFF”, specify the default gateway. If you are not using a default gateway, specify “0.0.0.0”. DNS SERVER Specify the DNS server address. If you are not using a DNS server, specify “0.0.0.0”. RESET
Clicking [Execute] returns all of the LAN SETUP settings to the factory-preset values except for the DNS SERVER setting.

NETWORK (GENERAL) This screen allows you to specify the general LAN settings.
MAIL (ORIGINATOR) This screen allows you to confi gure the e-mail sent periodically or when the monitor has an error. The settings depend on the confi guration of your LAN. Ask your LAN administrator for details.


SMTP SERVER Specify the SMTP server address for sending e-mail.
MONITOR NAME Specify a name for this monitor as it should appear on the Internet Explorer screen. AUTO LOGOUT TIME Specify the time (in minutes) to elapse before automatically disconnecting this monitor from the network. Specify in minutes from 1 to 65535. A value of ‘0’ will disable this function. DATA PORT Specify the TCP port number to use for exchanging data with the monitor. Specify a value from 1025 to 65535. SEARCH PORT Specify the port number to use when searching for this monitor. Specify a value from 1025 to 65535.
* When using a domain name, make sure to specify the DNS server as well. (See page 25.) ORIGINATOR E-MAIL ADDRESS Specify the e-mail address for this monitor. This address becomes the e-mail address of the originator. ORIGINATOR NAME Specify the name for the originator. This name appears in the “Originator Name” fi eld of the e-mail. AUTHENTICATION Specify the authentication method to use when sending e-mail. POP SERVER
If the “AUTHENTICATION” method is “POP before SMTP”, specify the POP server address. ACCOUNT NAME / PASSWORD If the “AUTHENTICATION” method is “POP before SMTP”, specify the account name and password to connect to the POP server.
The following characters can be used: a-z, A-Z, 0-9, - , .

MAIL (RECIPIENT) This screen allows you to specify the recipients of the e-mail sent periodically or when the monitor has an error.
MAIL (PERIODICAL) When PERIODICAL for CONDITION of MAIL (RECIPIENT) is checked, set the date and time to send the mail.


RECIPIENT E-MAIL ADDRESSES Specify the e-mail addresses to send error notifi cation e-mail to. CONDITION Specify the conditions to send mails. When you check PERIODICAL, specify the date and time to send the mails in the PERIODICAL setting. CONFIRMATION Sends test e-mail. This allows you to confi rm that the e-mail settings are confi gured properly. Attach the log fi le to a TEMPERATURE/HARDWARE error e-mail
DAY OF THE WEEK Specify the day of the week to send the periodical mails. TIME Specify the time of the day to send the periodical mails.
When this option is checked, a log is added to the mail which notifi es a temperature or status error.

SERVICE & SUPPORT
(URL INFORMATION) You can display a specifi c URL in the URL INFORMATION fi eld on the INFORMATION screen when an error occurs in the monitor. (See page 24.)

URL INFORMATION Enter a URL to display when an error occurs on the monitor. Up to 64 alphanumeric characters or symbols can be used. CONDITION Specify the condition to display the URL. CONFIRMATION The home page of the specifi ed URL is displayed. You can check whether the URL you entered is correct.


MESCA (Mitsubishi Electric Sales Canada Inc.) http://www.mitsubishielectric.ca Information Technologies Group, 4299 14th Avenue, Markham, Ontario L3R 0J2, Canada Sales Phone :+1-(905) 475-7728 Fax :+1-(905) 475-7958 E-mail :[email protected] Technical Phone :+1-(905) 475-7728 Fax :+1-(905) 475-7958 Customer Care
MEU-FRA (Mitsubishi Electric Europe B.V French Branch) 25, Boulevard des Bouvets 92 741, Nanterre CEDEX, France Sales Phone :+33 (0)1 55-68-55-07 Fax :+33 (0)1 55-68-57-31 Technical Phone :+33 (0)1 55-68-56-42 Fax :+33 (0)1 55-68-57-31
MEU-GER (Mitsubishi Electric Europe B.V. German Branch) http://www.mitsubishi-evs.de/ Gothaer Strasse 8, 40880 Ratingen, Germany
MEU-IR (Mitsubishi Electric Europe B.V. Irish Branch) http://www.mitsubishi.ie/ Westgate Business Park, Ballymount, Dublin 24, Ireland Sales Phone :+353-(0)1- 4198844 Fax :+353-(0)1-4564422 Technical Phone :+353-(0)1-4198807 Fax :+353-(0)1-4198895
E-mail :[email protected]
MDEA (Mitsubishi Digital Electronics America, Inc.) (Warranty Registration) http://www.mitsubishi-presentations.com/ Presentation Products Division, 9351 Jeronimo Road, Irvine, CA 92618 U.S.A Phone Main Line :+1-(949) 465-6000 Technical :+1-(888) 307-0309 Product Information :+1-(888) 307-0312 Technical Support E-mail :tsupport@mdea.com
MEU-IT (Mitsubishi Electric Europe B.V. Italian Branch) Centro Direzionale Colleoni, Palazzo Persero-Ingresso 2, Via Paracelso 12, 20041 Agrate Brianza, Italy Sales Phone :+39-(0)39-60531 Fax :+39-(0)39-6053214 E-mail :info.projector@it.mee.com
MEU-NL (MitsubishiElectric Europe B.V. Benelux Branch) http://www.MitsubishiElectric.nl Nijverheidsweg 23a, 3641 RP Mijdrecht, The Netherlands Sales Phone :+31-297-282461 Fax :+31-297-283936 E-mail :[email protected] Technical Phone :+31-297-282461 Fax :+31-297-283936 E-mail :[email protected]
MEU (MITSUBISHI ELECTRIC EUROPE B.V.) http://www.mitsubishi-projector.ru/ Moscow Representative Office, 12/1 Goncharnaya St. 109240, Moscow, Russia Sales Phone :+7 (095) 915 8602 Fax :+7 (095) 915 8603
MEU-SP (Mitsubishi Electric Europe B.V. Spanish Branch) http://www.mitsubishielectric.es/ Ctra. de Rubi, 76-80, 08190 Sant Cugat del Valles, Barcelona, Spain Sales Phone :+34-93.565.31.54 Fax :+34-93.589.43.88 E-mail :mitsubishi.profesional@sp.mee.com Technical Phone :+34-93.586.27.51 Fax :+34-93.699.74.45 E-mail :mitsubishi.profesional@sp.mee.com
MEU-SWE (Mitsubishi Electric Europe B.V Scandinavian Branch) Hammarbacken 14, Box 750, S-19127, Sollentuna, Sweden Sales Phone :+46-(0)8-6251070 Fax :+46-(0)8-6251036 Technical Phone :+46-(0)8-6251052 Fax :+46-(0)8-6251036
MEU-UK (Mitsubishi Electric Europe) http://www.mitsubishi.co.uk/evs/ Visual Information Systems Division, Travellers Lane, Hatfield, Hertfordshire, AL10 8XB Sales Phone :+44 (1707) 278684 Fax :+44 (1707) 278541 E-mail :projector.info@meuk.mee.com Technical Phone :+44 (870) 606 5008 Fax :+44 (1506) 431927 E-mail :projector.info@meuk.mee.com
Russia (Mitsubishi Electric Europe B.V Moscow Representative Office) 52, bldg.5, Kosmodamianskaya Nab, 113054, Moscow, Russian Federation Sales Phone :+7 (095) 721 2070 Fax :+7 (095) 721 2071 Technical Phone :+7 (095) 721 2070 Fax :+7 (095) 721 2071
North America · Europe
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.