EN
Mitsubishi Electronics logo
Official user manual

Mitsubishi Electronics CRT Monitor (1998E)

22 pages·266 KB·Computer Monitor·PDF·ENDEFRITNLJA
Mitsubishi Electronics CRT Monitor (1998E)
Table of Contents 14 sections DIAMOND VIEW 1998E · Colour Monitor · User’s Manual · UG/MO1998E/0902/1 · … ShowHide
Page 1 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — User’s Manual
Page 1 · click to enlarge
Page 1
Mitsubishi Electronics CRT Monitor (1998E) — DIAMOND VIEW 1998E diagram (page 1)
Fig. 1

DIAMOND VIEW 1998E

Colour Monitor

19” (48cm) CRT Size

18” (45.7cm) Viewable Area

User’s Manual

Page 2 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — UG/MO1998E/0902/1
Page 2 · click to enlarge
Page 2

Diamond View is a registered trademark of Mitsubishi Electric Australia Pty. Ltd. Microsoft and Windows are registered trademarks of Microsoft Corporation. Apple and Macintosh are registered trademarks of Apple Computer, Inc.

All other trademarks remain the property of their respective owners.

UG/MO1998E/0902/1

Page 3 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — UG/MO1998E/0902/1
Page 3 · click to enlarge
Page 3
Page 3 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — UG/MO1998E/0902/1
Page 4 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — Reference Information
Page 4 · click to enlarge
Page 4

Copyright 2002, Mitsubishi Electric Australia Pty. Ltd. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission.

Mitsubishi Electric Australia Pty. Ltd. makes no representations or warranties, either expressed or implied, with respect to the contents hereof and specifically disclaims any warranties, merchantability or fitness for any particular purpose. Further, Mitsubishi Electric Australia reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation to notify any person of such revision or changes.

Reference Information

For future reference, write the following information about your monitor in the space below. The serial number is on the back of the product or on the bottom of its stand.

Product NameDiamond View 1998E

Serial Number:

Date of Purchase:

Dealer:

Telephone Number:

Address:

Show 4 more labels / short text on this page
Copyright Notice · Disclaimer · Monitor Information · Dealer Information
Page 5 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — 1 Important Safety Instructions
Page 5 · click to enlarge
Page 5

1 Important Safety Instructions

Please read the following safety instructions before installing or cleaning your Diamond View monitor:

1. This monitor must be operated from the type of power source indicated on the rating label. If you are not sure of the type of power available in your area, consult your dealer or local electricity supply company.
2. This monitor must be operated with a 3 wire electrical cable that has a plug with a third (grounding) pin. The plug must only be connected to a grounded power outlet. This is a safety feature. Australian and New Zealand customers should use the power cable supplied with the monitor.
3. Make sure that the power outlet that you plug the monitor into is easily accessible.
4. Unplug the monitor’s power cable from the wall outlet before cleaning. Do not use liquid or aerosol cleaners. Use a soft cloth to clean the monitor housing and screen.
5. Slots and openings on the back or top of the cabinet are provided for ventilation. They must not be blocked or covered. This product should never be placed near or over a radiator or other heat source, or in a built-in installation unless proper ventilation is provided.
6. Never push objects of any kind, or spill liquid of any kind into the monitor.
7. Do not attempt to service the monitor yourself as opening or removing covers may expose you to dangerous voltages or other risks. Removing the cover of the monitor may void warranty.
8. If any abnormal operation or an accident (such as dropping the unit) occurs, disconnect the monitor from the wall power outlet and contact a Mitsubishi Authorised Service Centre (see chapter 8 for details).
Page 6 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — 2 Features
Page 6 · click to enlarge
Page 6

2 Features

Your Diamond View 1998E Monitor has the following features:

♦ Plug and Play Compatibility With DDC-2B, the 1998E is compatible with the Plug and Play features of Microsoft Windows 95, 98, 2000, XP and Millennium Edition.

♦ Compatible with PC, Apple Macintosh and most other computer systems.

♦ Flicker-free Image The monitor supports VESA standard graphics signals with flicker-free refresh rates at resolutions up to 1280 x 1024 pixels at 85Hz.

♦ Larger Viewable Size With its 45.7 cm (18”) diagonal viewable screen size, the 1998E offers a larger viewable screen area than many other 19” CRT monitors.

♦ Easy to Use On Screen Display The On-Screen Display (OSD) allows you to adjust all settings simply with on-screen menus.

♦ Power Saving Function The power management complies with VESA DPMS standard. When the system is idle (off mode), the monitor automatically cuts its power consumption to less than 5 watts.

♦ On Screen Display Allows you to adjust all settings simply using on-screen menus.

♦ Optional Multimedia Base is available Part number DVMB1.

♦ Green Commitment No CFCs are used in the manufacturing process of your monitor.

Page 7 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — 4 Installation
Page 7 · click to enlarge
Page 7

3 Unpacking the Monitor

Please check that the following items are included with your monitor. If they are missing or damaged, please contact your place of purchase immediately.

♦ Monitor with attached signal cable

Locate the model name and the serial number label on the back of your monitor and write the details of the monitor and your place of purchase in the space on page (ii) of this manual for future reference.

4 Installation

Your monitor is equipped with an automatic power supply with a voltage range from 100 to 240 Volts AC at a frequency of 50 to 60 Hz.

To install your Diamond View 1998E monitor:

1. Make sure that the computer system’s power is turned off.
2. Connect the power cord to the monitor and attach it to a power socket.

♦ Tilt/swivel base · ♦ Power cord · ♦ User’s manual

Page 8 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — 3 Unpacking the Monitor
Page 8 · click to enlarge
Page 8
3. Connect the computer end of the DSUB cable to the 15-pin output connector on the video board of your computer.
4. Turn the monitor and the computer on.

If you wish to connect the monitor to an older-type Apple Macintosh, you need to use a Macintosh cable adapter to connect the video signal cable of your monitor to the video port of the computer. Your computer dealer should be able to supply you with a suitable adaptor.

Drivers for Windows 95, 98, 2000, XP and Millennium Edition

Windows will detect the Diamond View 1998E monitor the first time you turn the computer on after installing it. The Add New Hardware wizard will prompt for drivers. Install the standard Windows Plug & Play Monitor driver. This driver will work correctly and allow you to use the monitor with its optimal resolutions and refresh rates.

A specific driver that includes the Windows ICC/ICM colour profile for the Diamond View 1998E is available from Mitsubishi Electric Australia’s web site at

http://www.mitsubishi-electric.com.au

Follow the link to the File Downloads/Monitors section of the site to download the drivers. Installation instructions are also available from the monitor driver page.

Page 9 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — 5 Adjusting the Monitor
Page 9 · click to enlarge
Page 9

5 Adjusting the Monitor

1 2 3 4 5

You can adjust the monitor using its On-Screen Display (OSD) menu system. There are 5 buttons that control the monitor:

1. Exit Returns to the last menu page, saves changes or quits the menu system.
2. and Move to another menu item or decrease the selected parameter. Hotkey for contrast adjustment.
3. and Move to another menu item or increase the selected parameter. Hotkey for brightness adjustment.
4. Enter Open a sub-menu or selects a menu item.
5. Power Switch Turn the monitor on or off.

Enter Exit

Page 10 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — 5 Adjusting the Monitor
Page 10 · click to enlarge
Page 10

Selecting Functions and Making Adjustments

1. Press to open the contrast adjustment display.
2. Press or to adjust the contrast level.
3. Press the Exit button to save your changes.
1. Press to open the brightness adjustment display.
2. Press or to adjust the contrast level.
1. Press the Exit button to save your changes.

The Main Menu The Diamond View 1998E’s OSD has a Main Menu that is organised into 6 groups of functions: Luminance, Geometry, Colour Adjustment, Recall, Degaussing and Miscellaneous. The remainder of this chapter describes the use of each function and the way that you can make adjustments to the image displayed on the monitor’s screen.

Contrast Hotkey · Brightness Hotkey

Page 11 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — 5 Adjusting the Monitor
Page 11 · click to enlarge
Page 11
1. In Main Menu: Press or to select the function group with the item that you wish to change.
Mitsubishi Electronics CRT Monitor (1998E) — 5 Adjusting the Monitor diagram (page 11)
Fig. 2 · 5 Adjusting the Monitor
2. Press Enter to open the Sub Menu.
Mitsubishi Electronics CRT Monitor (1998E) — 5 Adjusting the Monitor diagram (page 11)
Fig. 3 · 5 Adjusting the Monitor
3. Press or to select the item to be changed and press Enter .
4. Press or again to make the adjustment.

Make adjustments

Page 12 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — 5 Adjusting the Monitor
Page 12 · click to enlarge
Page 12
Mitsubishi Electronics CRT Monitor (1998E) — 5 Adjusting the Monitor diagram (page 12)
Fig. 4 · 5 Adjusting the Monitor
5. Press Exit to save the setting and return to the main menu.
1. Luminance

Contrast changes the difference between the light and dark areas of the displayed image.

Brightness adjusts the brightness of the displayed image.

Mitsubishi Electronics CRT Monitor (1998E) — 5 Adjusting the Monitor diagram (page 12)
Fig. 5 · 5 Adjusting the Monitor

Hor. Position adjusts the horizontal position of the image.

Ver. Position adjusts the vertical position of the image.

Pincushion: corrects curves in the vertical edges of the image.

Page 13 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — 5 Adjusting the Monitor
Page 13 · click to enlarge
Page 13

Unbalance adjusts the pincushion balance if both sides of the image are bowed toward either the left or the right.

Trapezoid makes the vertical edges of the image parallel.

Parallelogram aligns the top and bottom edges of the image.

Top corner adjusts the edge curvature at the top corners of the image.

Bottom corner adjusts the edge curvature at the bottom corners of the image.

3. Colour Adjustment

Colour mode Colour Temperature

C1 (9300K) 9300K User Mode 1

C2 (6500K) 6500K User Mode 2

Preset Colour Mode: In this mode, C1 and C2 are two memory areas where the factory-preset colour settings are stored. These settings are fixed and can not be modified.

User Colour Mode: Pressor to locate the colour mode and Enter to choose a colour. Pressor again to make the adjustment. If you want to reset to preset modes, please locate to recall the preset colour settings

Colour Temperature · (Preset Mode) · (User Mode)

Page 14 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — 5 Adjusting the Monitor
Page 14 · click to enlarge
Page 14
4. Recall/Reset and Image Status

Select and press Enter to recall the factory settings for the current graphics signal. The word “Recall” will blink on the screen in the process of recall.

This page is also a status display that shows the horizontal and vertical frequencies of the current graphics signal. Please note that the resolution is only displayed if you are using a graphics signal that corresponds with one of the monitor’s presets.

5. Manual Degaussing

To eliminate colour shading or impurity induced by magnetism. Press Enter to degauss the monitor. Use this function after moving the monitor or changing the direction that it is facing.

6. Miscellaneous

Hor. Moire adjusts horizontal Moiré.

Ver. Moire adjusts vertical Moiré.

If the picture is unstable when you adjust the Moiré reduction setting, over-adjustment has occurred. Please lower the Moiré reduction setting level.

OSD position changes the OSD’s position.

OSD Language:

DeDeutsch En :English Es : Español
FrFrançais It : Italiano
Page 15 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — 5 Adjusting the Monitor
Page 15 · click to enlarge
Page 15

The setting of each parameter is represented by a numeric value and

corresponding scale. The on-screen menu will automatically disappear after 20-second’s of

inactivity. If changes have been made, the monitor will automatically save them.

Timing and Refresh Rate Setting

By making adjustments of your video card settings, you can set the timing and the refresh rate to match your requirements. Please consult your operating system’s and graphics adaptor’s documentation for details about how this may be done.

The monitor will automatically save the changes that you make and use the new settings whenever you turn it on. The Diamond View 1998E monitor can accept horizontal scanning frequencies ranging from 30 KHz to 98 kHz and vertical frequencies from 50 Hz to 160 Hz. However, due to the requirements of signals with different resolutions, and to avoid possible damage to your monitor, do not exceed the following maximum vertical refresh rates.

800 x 600 150

1024 x 768 118

1280 x 1024 88

1600 x 1200 76

Resolution Maximum Vertical · Refresh Rate (Hz)

Page 16 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — 5 Adjusting the Monitor
Page 16 · click to enlarge
Page 16

Mode Resolution Vertical Frequency (Hz)

Industry 640 x 400 70 31.47 Industry 640 x 480 60 31.47 VESA 800 x 600 75 46.88 VESA 800 x 600 85 53.67 VESA 1024 x 768 75 60.02 VESA 1024 x 768 85 68.68 VESA 1280 x 1024 75 79.98 VESA 1280 x 1024 85 91.15 VESA 1600 x 1200 65 81.25

Factory Preset Timings · Horizontal Frequency (kHz)

Page 17 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — 6 Troubleshooting
Page 17 · click to enlarge
Page 17

6 Troubleshooting

If you encounter any trouble using the Diamond View 1998E monitor, make sure that your monitor is properly installed. (For hardware installation, see Chapter 4 of this manual.) If the problems persist, please check this chapter for possible solutions before calling Mitsubishi Electric or one of our Authorised Service Centres.

No image is displayed

- Check that the light (LED) next to the monitor’s power button is lit and

is green in colour.

- If the LED is orange there is no signal from the computer and the

monitor is in power saving mode. Check that the computer is switched on. Press a button on the computer keyboard or move the mouse to wake the computer. If that does not help, check that the VGA cable is securely plugged into the computer. Also check the pins of the VGA cable’s connector. If any pins are bent or broken off, then contact your dealer.

- If the LED is not lit at all, check that the monitor is plugged into the

power socket and that the power switch is turned on at the wall. Check that the monitor’s power switch is also turned on.

- Video sync signal. The video sync signal from the graphics card must

be as specified for the monitor.

The picture is scrolling or unstable.

- The most common cause of this problem is a loose VGA signal cable

or connector. Check that the cable is securely connected to the computer.

- Check the VGA signal cable for damage. If any pins are bent or

broken off, contact your dealer or an authorised Mitsubishi Electric service agent.

- Make sure that the graphics card settings are correct and within the

monitor’s specifications. Change the settings of your graphics card to values within the monitor’s range.

Page 18 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — 6 Troubleshooting
Page 18 · click to enlarge
Page 18

- Remove any magnetic objects that are near the monitor. These

include speakers and power supplies (AC adaptors).

Colours are impure.

- Check that the cable is securely connected to the computer.

- Check the VGA signal cable for damage. If any pins are bent or

broken off, contact your dealer or an authorised Mitsubishi Electric service agent (see Chapter 8 for details).

- Check the monitor’s colour settings. Press the Enter button and select

the Color Settings menu. Select the Recall menu item to return to the factory preset colours and press Enter.

- Degauss the monitor using the degauss function of the monitor’s On

Screen Display.

- Remove any objects that can create a magnetic field that may be

near the monitor. These include speakers and power supplies (AC adaptors ).

The image is blurred or there is visible ghosting

- Have you used a VGA extension cable? If so, remove the extension

cable and check the displayed image. Is the image quality improved? Depending on the characteristics and type of the extension cable, some blurring or distortion may occur due to conduction losses in the extension cable. You can minimise the distortion by using an extension cable with lower conduction losses.

- Have you used a VGA splitter or a video amplifier? Depending on the

characteristics and type of the splitter or amplifier some blurring or distortion may occur due to the limitations of the device’s bandwidth. Problems caused by a limited bandwidth will increase as the signal’s resolution and refresh rate increased. If you need to use a splitter or amplifier with you monitor, make sure that it is a good quality device that has sufficient bandwidth for the graphics resolution that you need to use.

Page 19 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — Model Diamond View 1998E
Page 19 · click to enlarge
Page 19

7 Specifications

Model Diamond View 1998E

Display Type 19” (48 cm) diagonal cathode ray tube

Maximum Viewable Size 18” (45.7cm) diagonal

Dot pitch 0.25 mm

Surface coating Anti-Glare, Anti-Reflective, Anti- Static coating

Maximum Resolution 1600 x 1200 pixels (at 75 Hz) Recommended Resolution 1280 x 1024 pixels (at 85 Hz) Horizontal Frequency 30 – 98 kHz Vertical Frequency 50 - 160 Hz Video Bandwidth 176 MHz Microprocessor Controlled Graphics 9 factory preset timings 15 user modes Signal Connection 15-pin mini D-sub cable

Video Input VGA-type (15 pin mini D-sub connector) Video Signal RGB analog (Positive polarity) 0.7 Vpp/75 Ohm

Synchronisation TTL separate, composite TTL

Plug & PLay DDC-2B

Display Characteristics · Graphics Signals

Page 20 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — 7 Specifications
Page 20 · click to enlarge
Page 20

Controls Mains power switch, On-Screen Display with 4 control buttons

On-Screen Display Functions:

Contrast; Brightness; Vert. & Hor. Image Position and Size; Pincushion Amplitude, Phase and Balance; Top and Bottom Corner Pincushion; Color Balance; Degauss; Horiz. and Vert. Moire; Choice of language (6 language OSD); OSD Position; Status Indicator

Power Management VESA DPMS, Energy Star

Maximum Power Consumption 110 Watts

Consumption in Power Saving Modes

Operating Voltage Automatic switched mode power supply, 100 - 240 V, 50 - 60 Hz

Dimensions (W x H x D) 455 x 466 x 463 mm

Temperature (Operating/Storage) 5 °C ~ 40 °C / -20 °C ~ 60 °C

Air Humidity (Operating/Storage) 20% ~ 90% / 10% ~ 90%

Safety AS/NZS 60950, UL, IEC 950, EN 60950 (TÜV/GS),

EMI/EMC AS/NZS 3548, Class B (C-Tick), CISPR 22 Class B, FCC Class B

Other TÜV/Ergonomics, ISO 9241-3/7/8, CE Mark, ISO 14000

Show 6 more labels / short text on this page
User Interface · Physical Characteristics · < 5 Watts · Weight 20 kg · Regulatory Certification · X-Ray DHHS
Page 21 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — 8 Service Contacts
Page 21 · click to enlarge
Page 21

8 Service Contacts

If problems remain after checking this manual, please contact your place of purchase or contact

Visit the Mitsubishi Electric Australia web site at

www.mitsubishi-electric.com.au

For details of your nearest Mitsubishi Electric Authorised Service Centre or contact the Service Department for your state:

New South Wales and Australian Capital Territory

348 Victoria Road Rydalmere, NSW, 2116

Telephone(02) 9684-7669
Fax(02) 9684-7684

1 / 104 Newmarket Road Windsor, Qld, 4030

Telephone(07) 3357-8877
Fax(07) 3357-8488

South Australia and Northern Territory

77 Port Road Hindmarsh, SA, 5007

Telephone(08) 8340-0444
Fax(08) 8340-0555

Australian Service Contacts · Queensland

Page 22 of the Mitsubishi Electronics CRT Monitor (1998E) user manual — 8 Service Contacts
Page 22 · click to enlarge
Page 22

4 / 303 Burwood Hwy East Burwood, Vic, 3151

Telephone(03) 9262-9899
Fax(03) 9262-9850

5 / 329 Collier Road Bassendean, WA, 6054

Telephone(08) 9377-3411
Fax(08) 9377-3499

New Zealand Service Contacts

Contact:

Melco New Zealand Ltd. 1 Parliament St. Lower Hutt Wellington

Telephone(04) 560-9100
Fax(04) 560-9140
Web sitewww.melco.co.nz

Victoria and Tasmania · Western Australia

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Mitsubishi Electronics CRT Monitor (1998E)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Mitsubishi Electronics CRT Monitor (1998E)

Be the first to ask — other owners or our team will answer.

Original document

Mitsubishi Electronics CRT Monitor (1998E) manual PDF

22 pages·266 KB·Computer Monitor·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…