Page 1 of the Mitsubishi Electronics LGH-65RX4-E user manual — Models LGH-15 to 100 RX 4 Models LGH-150 and 200 RX 4
Page 1 · click to enlarge
Page 1

English

Lossnay Models:

LGH-15RX4-E, LGH-25RX4-E, LGH-35RX4-E LGH-50RX4-E, LGH-65RX4-E, LGH-80RX4-E LGH-100RX4-E, LGH-150RX4-E, LGH-200RX4-E

Operating Instructions (For the user)

Please read through these instructions in order to familiarize yourself with the proper and safe procedures for operat- ing the Lossnay. After reading this manual, keep it in an easily accessible and safe place for future reference.

Safety precautions

The following signs indicate that death or serious injury may be caused by a failure to heed the precautions described below and the resultant mishandling of the product.

WARNING

G This product must not be disassembled under any circumstances. Only authorized repair technicians are qualified to conduct

disassembly and repairs. (Failure to heed this warning may result in fire, electrical shock or injury.) If your product needs to be repaired, consult your dealer.

G Do not splash water over this product.

(Failure to heed this warning may result in fire and/or electrical shock.) G If flammable gases should leak, do not turn the Lossnay’s switch on or off.

(Failure to heed this warning may cause the electrical contacts to generate sparks which may result in an explosion.) Open windows to ventilate.

G Do not poke your fingers or sticks into the air intake and outlet while the product is operating.

(Failure to heed this warning may result in injury.)

G Gloves should be worn when doing the installation and maintenance work.

(Failure to heed this warning may result in injury.) G Be sure that the power board circuit breaker is in the OFF position and is securely locked by lock and key before proceeding with

maintenance work. (Failure to heed this warning may result in electrical shock or injury.) G In the event of trouble (smell of burning, etc.), shut down operation, set the power board circuit breaker to its OFF position and

consult your dealer. (Continued operation without remedying the trouble may result in electrical shock, fire, etc.)

Names of the parts

Models LGH-15 to 100 RX 4 Models LGH-150 and 200 RX 4

3 Lossnay core holder

3 Lossnay core holder

Mitsubishi Electronics LGH-65RX4-E — Models LGH-15 to 100 RX 4 Models LGH-150 and 200 RX 4 diagram (page 1)
Fig. 1 · Models LGH-15 to 100 RX 4 Models LGH-150 and 200 RX…

2 Control box 4 Air supply fan

4 Air supply fan

Mitsubishi Electronics LGH-65RX4-E — Models LGH-15 to 100 RX 4 Models LGH-150 and 200 RX 4 diagram (page 1)
Fig. 2 · Models LGH-15 to 100 RX 4 Models LGH-150 and 200 RX…

7 Air filter 5 Lossnay core

6 Air exhaust fan

8 Damper plate 6 Air exhaust fan

Show 11 more labels / short text on this page
No disassembly · Prohibited · Do not touch · Instructions · must be followed · 1 Maintenance cover · 1 Maintenance cover · 2 Control box · 5 Lossnay core · 7 Air filter · 8 Damper plate
Page 2 of the Mitsubishi Electronics LGH-65RX4-E user manual — MELANS
Page 2 · click to enlarge
Page 2

Operation

1. For connection of a remote controller (PZ-41SLB-E)

If the Lossnay’s operation is linked with the operation of an external device such as an air conditioner, the method of use will differ, so carry out the appropriate operation in accordance with the following table. Also, please see the installation and user’s manual for the remote controller (PZ-41SLB-E). <If not connected to an external device>

Example of SystemOperationFunction Lossnay Remote Controller (Optional parts) (PZ-41SLB-E) Power SupplyRun using the remote controller.• If 2 remote controllers are used, the last controller to be used has priority. (Last Command)

<If connected to an external device>

Remote Controller Lossnay (Optional parts) (PZ-41SLB-E) Power Supply External device Operation switch for the external device Power SupplyIf an external device is connected the “On/Off” function of this device will also control the Lossnay operation.• If you would like to turn ON the Lossnay alone while the external device is OFF, operate it by the Lossnay remote controller. Lossnay Power Supply External device Operation switch for the external device Power Supply• The fan speed is on “High”. • The ventilation mode is “Ventilation Mode Auto Select”.
Mitsubishi Electronics LGH-65RX4-E — <If connected to an external device> diagram (page 2)
Fig. 3 · <If connected to an external device>
Mitsubishi Electronics LGH-65RX4-E — <If connected to an external device> diagram (page 2)
Fig. 4 · <If connected to an external device>
2. For connection of a Lossnay remote controller (PZ-52SF-E), Mitsubishi Electric Air-Conditioner Network System (MELANS) or City Multi.

I LOSSNAY VENTILATE setting

Both fresh air supply and return air pass through the Lossnay core(s). Resulting in full heat exchange. Lossnay ventilate setting is used for cooling in the summer and heating in the winter period.

Models LGH-15 to 100 RX4 Models LGH-150 and 200 RX4

This is to be incorporated and used in the Mitsubishi Electric Air- Conditioner Network System. This is interlocked with the City Multi and operated by it. If the Lossnay remote controller (PZ-52SF-E) is used, the Lossnay may be operated independently if connected to City Multi. For details, refer to the operating manual of PZ-52SF-E.

Supply air Supply air

Exhaust air Return air Supply air

Lossnay operation using the Lossnay remote controller (PZ-52SF- E) should need the power supply unit. Refer to the system diagram below.

I BY-PASS VENTILATE setting

The fresh air passes through the Lossnay core(s) and the return room air is exhausted direct. Lossnay bypass ventilate is normally operated during the spring/autumn months.

Note

  • If this is to be used with the Lossnay remote controller (PZ52SF-E), refer to the manuals for both the PZ-52SF-E installation and operating manual.

Damper Models LGH-15 to 100 RX4 Models LGH-150 and 200 RX4

  • Remote controller PZ-41SLB-E cannot be used with this system.

Return air Supply air

I System diagram

Return air Supply air Exhaust air

MELANS

I AUTOMATIC VENTILATION setting

PAC-SC34KUA Lossnay unit LGH-**RX4-E

The automatic damper mode automatically provides the correct ven- tilation for the conditions in the room. The following shows the effect “By-pass” ventilation will have under various conditions.

Lossnay remote controller (PZ-52SF-E)

Interlocked to the City Multi indoor unit

City Multi indoor unit

Lossnay unit LGH-**RX4-E

Show 28 more labels / short text on this page
Damper · Damper · Exhaust air · Return air · Exhaust air · Return air · Fresh air · Fresh air · Fresh air · Lossnay core · Lossnay core · Damper · Exhaust air · Return air · Exhaust air · Fresh air · Fresh air · Supply air · Fresh air · Basic system · M-NET transmission line · Lossnay core · Lossnay core · Power supply unit · Power supply · M-NET transmission line · Power supply · A/C’s remote controller
Page 3 of the Mitsubishi Electronics LGH-65RX4-E user manual — CAUTION
Page 3 · click to enlarge
Page 3

Operation (Continued)

English

1. Reduces cooling load If the air outside is cooler than the air inside the building during the cooling season (such as early morning or at night), “By-pass” ventilation will draw in the cooler outside air and reduce the cooling load on the system.
3. Office equipment room cooling During cold season, outdoor air can be drawn in and used as is to cool rooms where the temperature has risen due to the use of office equipment. (Only when interlocked with City Multi and Mr. Slim indoor unit)
2. Night purge “By-pass” ventilation can be used to release hot air from inside the building that has accumulated in buildings a business district during the hot summer season.

Maintenance

Remove all dust and dirt on air filters and Lossnay core(s) at regular intervals in order to prevent a deterioration in the Lossnay functions. Guideline: Clean the air filters once a year. Clean the Lossnay core(s) once two year.

Removing the parts

1) Maintenance cover

Locate and remove the cover fixing screw. Pull back the hinged clip. Open the door and lift off of the hinge brackets.

Maintenance cover Maintenance covers

Cleaning the parts

1) Air filters

Use a vacuum cleaner to remove light dust. To remove stubborn dirt wash in a mild solution of detergent and lukewarm water. (under 40°C)

Mitsubishi Electronics LGH-65RX4-E — 1) Air filters diagram (page 3)
Fig. 5 · 1) Air filters

Models LGH-15 to 100 RX4 Models LGH-150 and 200 RX4

2) Lossnay core(s)

Take hold of the handle and draw the Lossnay cores out from the main unit.

CAUTION

  • Never wash the filters in very hot water and never wash them by rubbing them.

Model LGH-15 RX4: 1 core Models LGH-25 to 100 RX4: 2 cores Models LGH-150 and 200 RX4: 4 cores

  • Do not dry the filters by exposing them to a flame.

Lossnay core Handle Handle

2) Lossnay core

Use a vacuum cleaner to suck up the dust and dirt on the exposed surfaces of the Lossnay cores. Use a soft brush only to clean ex- posed surface areas.

Do NOT wash in water.

Mitsubishi Electronics LGH-65RX4-E — 2) Lossnay core diagram (page 3)
Fig. 6 · 2) Lossnay core

Models LGH-15 to 100 RX4 Models LGH-150 and 200 RX4

3) Air filters

After pulling out the Lossnay core(s), pull the air filters, located at the bottom left and right of the Lossnay core(s), off the velcro that holds them in place.

Corner Vacuum cleaner (with brush attachment)

CAUTION

  • Do not use the hard nozzle of the vacuum cleaner. It may damage the exposed surfaces of the Lossnay core(s).

Models LGH-15 RX4: 2 filters Models LGH-25 to 100 RX4: 4 filters Models LGH-150 and 200 RX4: 8 filters

  • Under no circumstances should the Lossnay core(s) be washed in water.
Show 13 more labels / short text on this page
Velcro · Lossnay core · Air filters · Hinge bracket · Hinge · Hinge · Hinge bracket · Vacuum cleaner · Air filter · Lossnay · core · Main unit · Lossnay core
Page 4 of the Mitsubishi Electronics LGH-65RX4-E user manual — After-sales servicing
Page 4 · click to enlarge
Page 4

Maintenance (Continued)

Assembly after maintenance

2. Press the filter button on the remote controller (PZ-41SLB-E) two times in succession. (This clears the Lossnay’s operating time cumulative data.)
  • 1. Bearing in mind the following points, assemble the parts following the sequence for their removal in reverse.
  • Attach the air filters to the magic tape on the Lossnay core(s).
  • Arrange the Lossnay core with the air filter side downward.
Relevant buttonRelevant display items FILTER (Press twice)FILTER
Mitsubishi Electronics LGH-65RX4-E — Maintenance (Continued) diagram (page 4)
Fig. 7 · Maintenance (Continued)

Specifications

60HzInvalid in EU
Model nameVoltage (V)Line frequency (Hz)Current (A)Power consumption (W)Air volumeStatic pressureExchange efficiency (%)Noise (dB(A))Weight (kg) (m3 /h)(L/S)TemperatureEnthalpyBelow the unitAir outlets (mmH2O)(Pa)HeatingCooling LGH15RX41-Phase 220 - 240500.29-0.3163-73150426.160777064.524-2530-31.517 600.33-0.3572-84150428.280777064.525-2631-32.517 LGH25RX41-Phase 220 - 240500.39-0.4085-96250695.15078706525-2633-3421 600.45-0.4798-112250696.16078706525.5-26.533.5-34.521 LGH35RX41-Phase 220 - 240500.71-0.71154-167350977.17079706828-3035-3730 600.83-0.87180-207350975.15079706827-2934-3630 LGH50RX41-Phase 220 - 240500.89-0.90193-2145001396.1607767.564.529.5-31.537.5-39.533 601.05-1.10231-2625001396.1607767.564.528.5-3136.5-3933 LGH65RX41-Phase 220 - 240501.30-1.30270-3006501815.150766864.532.5-3340.5-4146 601.50-1.60320-3706501817.170766864.532.5-3340.5-4146 LGH80RX41-Phase 220 - 240501.60-1.60340-37080022210.210078716732-3343-4461 601.90-2.00405-46580022212.212078716731-32.542-43.561 LGH100RX41-Phase 220 - 240502.00-2.00440-475100027810.210079716734-3545-4669 602.60-2.70565-635100027811.211079716734-3645-4769 LGH150RX41-Phase 220 - 240503.10-3.10670-730150041710.210079726835.5-36.544-45124 603.80-3.90820-935150041712.212079726835-3643.5-44.5124 LGH200RX41-Phase 220 - 240504.20-4.20910-98020005569.29079716737-3845.5-46.5140 605.30-5.401155-1295200055610.210079716736.5-38.545-47140

(1mmH2O = 9.80665Pa)

* The values given in the table for the noise level reflect the levels measured at a position 1.5 meters immediately below the unit in an anechoic chamber.

* The noise at the air outlets is the values at a 45° angle, 1.5 meters in front of the unit.

* The above values apply during Lossnay ventilation when the fan speed is set to high speed.

* The values for 150 and 200 type main unit outlet noise show in the case of 1 supply air duct.

After-sales servicing

Consult with your dealer about the after-sales services provided for this Lossnay product.

If you hear strange sounds, if no air is blown out or if some other trouble occurs, switch off the power and contact your dealer. Consult with your dealer concerning the cost of inspection or repair work.

Ask about the Mitsubishi Electronics LGH-65RX4-E

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Mitsubishi Electronics LGH-65RX4-E

Be the first to ask — other owners or our team will answer.

Original document

Mitsubishi Electronics LGH-65RX4-E manual PDF

4 pages·1.4 MB·Air Conditioner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…