C6/C64/C64T
PARAMETER MANUAL














MELDAS and MELSEC are registered trademarks of Mitsubishi Electric Corporation. Microsoft and Windows are a registered trademark of Microsoft Corporation in the United States and/or other countries. Other brands and product names throughout this manual are trademarks or registered trademarks of their respective holders.

Introduction This manual is a guide of the parameters used with the CNC MELDAS C6/C64/C64T. This manual is written on the assumption that all machine parameters of the MELDAS C6/C64/C64T are provided. However, the CNC may not necessarily be provided with all of the options. When the system is used, therefore, reference should be made to the Specifications Manual issued by the machine maker. Points to be observed when reading this manual (1) This manual contains general descriptions as seen from the standpoint of NC
(numerical control) and thus refer to the Instruction Manual issued by the machine maker for descriptions of individual machine tools. The Instruction Manual issued by the machine maker takes precedence over this manual when any mention of "restrictions", "usable states" or such details are mentioned. (2) As much information as possible on special procedures has been included in this
manual, and it may be considered that any procedures not mentioned cannot be undertaken. (3) Also refer to the following manuals.
For items described as "Restrictions" or "Usable State" in this manual, the Instruction
Manual issued by the machine maker takes precedence over this manual.
Items that are not described must be interpreted as "not possible".
This manual is written on the assumption that all option functions are added. Refer to the
Specifications Manual issued by the machine maker before starting use.
Refer to the manuals issued by the machine manufacturer for each machine tool
explanation.
Some screens and functions may differ or may not be usable depending on the NC system
version.

Precautions for Safety Always read the Specifications Manual issued by the machine maker, this manual, related manuals and attached documents before installation, operation, programming, maintenance or inspection to ensure correct use. Understand this numerical controller, safety items and cautions before using the unit. This manual ranks the safety precautions into "DANGER", "WARNING" and "CAUTION".
When the user may be subject to imminent fatalities or major injuries if handling is mistaken. When the user may be subject to fatalities or major injuries if handling is mistaken. When the user may be subject to injuries or when physical damage may occur if handling is mistaken.
WARNING
CAUTION
Not applicable in this manual.
Not applicable in this manual.
For items described as "Restrictions" or "Usable State" in this manual, the Instruction Manual issued by the machine maker takes precedence over this manual. Items that are not described must be interpreted as "not possible". This manual is written on the assumption that all option functions are added. Refer to the Specifications Manual issued by the machine maker before starting use. Refer to the manuals issued by the machine manufacturer for each machine tool explanation. Some screens and functions may differ or may not be usable depending on the NC system version.

To change the control mode to the High-gain amp (MDS-B-V14/V24) mode after
replacement of the Standard amp (MDS-B-V1/V2), it is need to change the parameters and to adjust the servo parameters to fit to the High-gain amp.
Mode change between the Standard amp mode and the High-gain amp mode is
actually performed when the power (200V) is turned ON. Thus, when changing some parameters unique to each amp, an alarm “7F” occurs and requests to turn the power ON again. Note that the alarm “7F” may occur when the amp is mounted on the machine for the first time. When the alarm “7F” occurs, turn the power ON again. The alarm “7F” may not occur at second turning ON or later unless the above-mentioned
parameters are changed.
With MDS-C1 series, only the serial encoder is applied as the motor end detector.
Thus, OHE/OHA type detector cannot be used as the motor end detector.
Do not make remarkable adjustments or changes of the parameters as the operation
may became unstable.
When setting the parameter (#6449/bit6, 7) not to check the overheat, the control unit
and the communication terminal may not be controlled because of overheat. In such case, axis runaway may cause a machine breakage, an accident resulting in injury or death, or device breakage. To prevent the serious results, ordinarily set the parameters so that the overheat check is valid.


The parameter input setting units are as follow.


The following menus can be selected when the key
(1) User parameters

The following menus can be selected when SETUP is selected. (Refer to the section "4. Setup Parameters" for details.

(3) The following menus can be selected when the key
DIAGN is pressed.
(2) Setup Parameters



(No. of workpieces machined)

(Automatic tool length measurement)

(Automatic corner override)

(Wear data input)


(Fixed cycle)
(High precision control)


# Item Contents Setting range (unit) 8201 AX. RELEASE Select the function to remove the control axis from the control target.
8202 OT-CHECK OFF Select the stored stroke limit function set in #8204 and #8205.
8203 OT-CHECK-CANCEL When the simple absolute position method ("#2049 type" is 9) is selected‚ the stored stroke limits I, II (or IIB) and IB will be invalid until the first reference point return is executed after the power is turned on.
stroke limits.
8204 OT-CHECK-N Set the coordinates of the (–) direction in the moveable range of the stored stroke limit II or the lower limit coordinates of the prohibited range of stored stroke limit IIB. If the sign and value are the same as #8205 (other than "0"), the stored stroke limit II (or IIB) will be invalid. If the stored stroke limit IIB function is selected, the prohibited range will be between two points even when #8204 and #8205 are set in reverse. When II is selected, the entire range will be prohibited.
–99999.999 to +99999.999 (mm)
8205 OT-CHECK-P Set the coordinates of the (+) direction in the moveable range of the stored stroke limit II or the upper limit coordinates of the prohibited range of stored stroke limit IIB.
–99999.999 to +99999.999 (mm)
8206 TOOL CHG. P Set the coordinates of the tool change position for G30. n (tool change position return). Set with coordinates in the basic machine coordinate system.
–99999.999 to +99999.999 (mm)
8207 G76/87 IGNR (For M system only)
Select the shift operation at G76 (fine boring) and G87 (back boring).

# Item Contents Setting range (unit) 8208 G76/87 (–) (For M system only)
Specify the shift direction at G76 and G87.
8209 G60 SHIFT (For M system only)
–99999.999 to +99999.999 (mm) 8210 OT INSIDE The stored stoke limit function set in #8204 and #8205 prevents the machine from moving to the inside or outside of the specified range.
Set the last positioning direction and distance for a G60 (uni-directional positioning) command.
# Item Contents Setting range (unit) 8300 P0 (For L system only)
Set the reference X-coordinates of the chuck and the tail stock barrier. Set the center coordinate (Radius value) of workpiece by the basic machine coordinate system.
–99999.999 to +99999.999 (mm)
8301 8302 8303 8304 8305 8306
P1 P2 P3 P4 P5 P6 (For L system only)
Set the area of the chuck and tail stock barrier. (Radius value) Set the coordinate value from the center of workpiece for X-axis. Set the coordinate value by basic machine coordinate system for Z-axis.
–99999.999 to +99999.999 (mm)
0/1 · 0/1

<I/O> # <PORT No.> # <DEV. No.> <DEV. NAME> Specify the board No. to which the serial input/output device is connected to each application.
Set the input/output device No. for each application. The device Nos. are 0 to 4 and correspond to the input/output device parameters. The device name set in the input/output device parameter is also displayed for identification. DATA IN 9001 Specify the port for inputting the data such as machine program and parameters.
9002 Specify the No. of the device that inputs the data.
DATA OUT 9003 Specify the port for outputting the data such as machine program and parameters.
9004 Specify the No. of the device that outputs the data.
TAPE MODE 9005 Specify the input port for running with the tape mode.
9006 Specify the No. of the device to be run with the tape mode. MACRO PRINT
9008 Specify the No. of the device for the DPRINT command. PLC IN/OUT 9009 Specify the port for inputting/outputting various data with PLC.
9007 Specify the output port for the user macro DPRINT command.
9010 Specify the No. of the device for the PLC input/output. REMOTE PROG IN
9011 Not used. 9012 Not used.

Parameters for up to five types of input/output devices can be set in DEV to . (Note) The parameters are set for each device.
9101 ~ Set the same settings for device 0. 9201 ~ Set the same settings for device 1. 9301 ~ Set the same settings for device 2. 9401 ~ Set the same settings for device 3. 9501 ~ Set the same settings for device 4.
# Item Contents Setting range (unit) 9101 9201 9301 9401 9501
Use alphabet characters‚ numerals and symbols to set a name within 3 characters. 9102 9202 9302 9402 9502
DEVICE NAME 0 DEVICE NAME 1 DEVICE NAME 2 DEVICE NAME 3 DEVICE NAME 4
Set the device name corresponding to the device No. Set a simple name for quick identification.
BAUD RATE Set the serial communication speed. 1: 9600 (bps) 2: 4800 3: 2400 4: 1200 5: 600 6: 300 7: 150 9103 9203 9303 9403 9503
STOP BIT Set the stop bit length used in the start-stop system. 1: 1 (bit)
9104 9204 9304 9404 9504
PARITY CHECK Specify whether to add the parity check bit to the data during communication.
9105 9205 9305 9405 9505
EVEN PARITY Specify the odd or even parity when it is added to the data.
9106 9206 9306 9406 9506
CHR. LENGTH Set the length of the data bit. 0: 5 (bit) 1: 6 2: 7 3: 8

# Item Contents Setting range (unit) 9107 9207 9307 9407 9507
TERMINATOR TYPE The code to terminate data reading can be selected. 0 and 3: EOR
9108 9208 9308 9408 9508
HAND SHAKE Specify the transmission control method. The method will be no procedure if a value except 1 to 3 is set.
DC CODE PARITY Specify the DC code when the DC code method is selected.
9111 9211 9311 9411 9511
DC2 / DC4 0: None / None 1: Yes / None 2: None / Yes 3: Yes / Yes 9112 9212 9312 9412 9512
DC2/DC4 OUTPUT Specify the DC code handling when outputting data to the output device.
CR OUTPUT Specify whether to insert the code just before the EOB (L/F) code during output.
9113 9213 9313 9413 9513
EIA Output In data output mode, select the ISO or EIA code for data output. In data input mode, the ISO and EIA codes are identified automatically.
9114 9214 9314 9414 9514
FEED CHR. Specify the length of the tape feed to be output at the start and end of the data during tape output.
0 to 999 (characters)
9115 9215 9315 9415 9515
PARITY V Specify whether to check the parity of the No. of characters in block during data input. The No. of characters is factory-set so that the check is valid at all times.

# Item Contents Setting range (unit) 9116 9216 9316 9416 9516
TIME-OUT (s) Set the time out time to detect an interruption in communication. The time out is not checked when 0 is set, so the waiting time will be infinite. The screens cannot be changed during the waiting time. Set this time to 10 as the standard.
0 to 30 (s)
9117 9217 9317 9417 9517
DR OFF Specify whether to check the DR data at the data input/output.
9118 9218 9318 9418 9518
DATA ASC II 0: Output in ISO/EIA code (Depends on whether #9113, #9213, #9313, #9413, or #9513 EIA output parameter is set up) 1: Output in ASC II code
9119 9219 9319 9419 9519
INPUT FORM Specify the mode for input (collation). 0: Standard input (Data from the very first EOB is handled as significant information.) 1: EOBs following the first EOB of the input data are skipped until data other than EOB is input.
9121 9221 9321 9421 9521
EIA CODE [ When outputting with the EIA codes, special ISO codes not included in EIA can be output with alternate codes. For each special code, designate a code (as a hexadecimal) that is not duplicated with existing EIA codes. (Continued on the next page.)
0 to FF (hexadecimal)
9122 9222 9322 9422 9522
9123 9223 9323 9423 9523
9124 9224 9324 9424 9524

# Item Contents Setting range (unit)
9125 9225 9325 9425 9525
(Continued from the previous page.)
9126 9226 9326 9426 9526
:
9127 9227 9327 9427 9527
9128 9228 9328 9428 9528
= · $ · !

Pressing the menu key SETUP displays the OPEN SETUP PARAM screen.
The system’s basic parameters are normally hidden as setup parameters to prevent mistaken operations and to simplify the display. The setup parameters can be displayed and set by making a declaration to open the setup parameters on this screen.
Open the menu setup parameter? *YES : "Y" "INPUT" *NO : "N" "INPUT"
SETUP
Refer to "5. Base Specifications Parameters" and following for details on the setup parameters. Be sure to turn off the power supply after selecting the setup parameter.
# ( )

After setting up the parameter (PR) listed in the table, turn off the NC power. To validate the parameter, turn on the power again.
# Items Details Setting range (unit)
Specify the presence of the PLC axes and the 1st to 7th part systems with 1 or 0. 0: Not used 1: Used
axisno Number of axes
Set No. of axes in each part system and the No. of PLC axes. Set so that the total of the NC axes and PLC axes is less than the maximum number of controllable axes.
iunit Input setup unit
Specify the input setting value for each part system and the PLC axis. The parameter units will follow this specification.
B: 1 µm C: 0.1 µm
1013 axname Axis name Specify each axis’ name address with an alphabetic character. Use the characters X‚ Y‚ Z‚ U‚ V‚ W‚ A‚ B or C. Do not specify the same address in one part system. The same address can be specified as the other part system. The PLC address does not need to be set. (The axis name is displayed as 1 and 2.)
Axis addresses such as X, Y, Z, U, V, W, A, B, and C
1014 incax Increment command axis name
When specifying the program movement rate’s absolute or incremental method with an address‚ specify the incremental command axis name address with an alphabetic character. The address that can be used is the same as "#1013 axname". Specify an address that is different from that #1013. Setting is not required if absolute/incremental command with addresses is not performed ("#1076 Abslnc" = 0).
Specify the minimum unit of the program movement amount. cunit Movement amount for movement command 1 10: 0.001 mm ( 1 µm) 100: 0.01 mm ( 10 µm) 1000: 0.1 mm (100 µm) 10000: 1.0 mm If there is a decimal point in the movement command‚ the decimal point position will be handled as 1mm regardless of this setting.
10 1 µm
100 10 µm
1000 100 µm
iout Inch output Specify whether the machine system (ball screw pitch‚ position detection unit) is an inch unit system or metric unit system.

# Items Details Setting range (unit)
Specify whether the axis is a rotary axis or linear axis. For the rotary axis‚ the position display will be 360 degrees‚ and the axis will return to 0 degrees. If the position display is to be continuously displayed even with the rotary axis‚ set the axis as a linear axis
ccw Motor CCW Specify the direction of the motor rotation to the command direction.
dia Diameter specification axis
Specify whether the program movement amount is to be commanded with the diameter dimension or as movement amount. When the movement amount is commanded with the diameter dimensions‚ 5mm will be moved when the command is a movement distance of 10mm. The movement amount per pulse will also be halved during manual pulse feed. Among parameters concerning length‚ the tool length‚ the wear compensation amount and the workpiece coordinate offset are displayed in diameter value when diameter is specified‚ but other parameters are always displayed in radius value.
Specify 1 when the NC control axis is used as the spindle.
rot Rotational axis · sp_ax Spindle Interpolation

# Items Details Setting range (unit)
1025 l_plane Initial plane selection
Specify the plane to be selected when the power is turned on or reset. When 0 is specified, 1 is assumed (X-Y plane).
Base axis I Base axis J Base axis K
Specify the basic axis address that composes the plane. Specify the axis address set in “#1013 axname”. Set the axis name even when there is no need to configure a plane, such as the case of 2-axis specifications. Normally‚ when X‚ Y and Z are specified respectively for base_l‚_J‚_K‚ the following relation will be established:
Control axis addresses such as X, Y, and Z
G17: X-Y G18: Z-X G19: Y-Z Specify the desired address to set an axis address other than the above.
1029 aux_I Flat axis I If there is an axis parallel to "#1026 base_l"‚ specify that axis address.
Control axis addresses such as X, Y, and Z
1030 aux_J Flat axis J If there is an axis parallel to "#1027 base_J"‚ specify that axis address.
Control axis addresses such as X, Y, and Z
1031 aux_K Flat axis K If there is an axis parallel to "#1028 base_K"‚ specify that axis address.
Control axis addresses such as X, Y, and Z
1026 1027 1028 · base_l base_J base_K

# Items Details Setting range (unit)
1037 cmdtyp Command type
Specify the program G code series and compensation type.
cmdtyp G code series Compensation type 1 System 1 (for M) Type A (one compensation amount for one compen- sation number) 2 System 2 (for M) Type B (shape and wear amounts for one compen- sation number)
3 System 2 (for L) Type C (two kinds of compensation amount of shape and wear per compensation No.)
4 System 3 (for L) Same as above
5 System 4 (for special L)
6 System 5 (for special L)
7 System 6 (for special L)
8 System 7 (for special L)
There are some items in the specifications that can be used or cannot be used according to the value set in this parameter. The file structure may also change depending on the compensation data type. Thus‚ after changing this parameter‚ initialize the system with "#1060 SETUP".
"BASE PARA SET? (Y/N)" : N INPUT
"FORMAT? (Y/N)" : Y INPUT
↓ "SETUP COMPLETE" (Note) The machining program is cleared with the
above operations. Back up necessary machining programs in an external memory before initializing.
1038 plcsel Ladder selection
Specify the PLC type. 0 to 2

# Items Details Setting range (unit)
1039 spinno Number of spindles
Specify the existence of a spindle.
Specify the parameter unit system for the position and length.
l_inch Initial state (inch)
Specify the unit system for the program movement amount when the power is turned on or reset and for position display.
pcinch PLC axis command (inch)
Specify the unit system for the commands to the PLC axis.
1043 lang Select language displayed
Specify the display language.
specified language, the screen is displayed in English.
Specify the number of MR-J2-CT axes connected. As for C6/C64 system, up to 5 axes of MR-J2-CT can be connected, thus, the setting range is 0 to 5.
(Note) Selection of inch and metric unit
When set value of "#1041 I_inch" is changed‚ the unit of length is changed after reset. Among parameters concerning length‚ following items are not changed automatically‚ therefore change the set values to agree with the new unit system when the unit system is changed.
Tool compensation amount (Tool length compensation amount‚ tool wear compensation amount and tool tip compensation amount) Workpiece coordinate offset Machining parameter #8004 SPEED #8013 G83n #8052 PULL UP #8005 ZONE r #8016 G71 MINIMUM #8053 G73U #8006 ZONE d #8017 G71 DELTA-D #8054 W #8009 DSC. ZONE #8018 G84/G74n #8056 G74 RETRACT #8010 ABS. MAX. #8027 Toler-1 #8057 G76 LAST-D #8011 INC. MAX. #8028 Toler-2 #8012 G73n #8051 G71 THICK Axis parameter #8204 OT-CHECK-N #8205 OT-CHECK-P #8206 TOOL CHG.P #8209 G60 Shift Barrier data #8300 – #8306 Basic specification parameter #1084 RadErr
#8004 SPEED is 10 inches/min. unit for the inch system.


one-touch setup‚ so confirm the data before executing. This parameter will automatically be set to 0 when the power is turned on.
Defines whether to update the absolute value data during automatic handle interrupt. This parameter is valid only when "#1145 l_abs" is set to 1.

# Items Details Setting range (unit)
1062 T_cmp Tool offset function
Specify whether the tool length offset and wear compensation is valid during T command execution.
Setting value Tool length offset Wear compensation 0 Valid Valid 1 Valid Invalid 2 Invalid Valid 3 Invalid Invalid
1063 mandog Manual dog-type
The initial return to the reference point is performed with dog-type return after the power is turned on‚ and the coordinate system is established. Specify the manual reference point return method after the coordinate system is established with this parameter. (This setting is not required when using absolute position detection.)
Specify whether to correct the error when the servo is off.
1065 JOG_H JOG response type
Set up an improved JOG response type.
0: Conventional specification The system is started and stopped by signals via ladder without reference to external input signals. 1: Type 1 The system is started up and stopped by external signals. 2: Type 2 The system is started up and stopped by performing the AND operation for external signals and signals via ladder. 3: Type 3 The system is started up when signals via ladder rise. It is stopped when external signals and signals via ladder fall. 4: Type 4 Reference point return mode:
The system is started up and stopped by signals via ladder without reference to external input signals (conventional specification). Non-reference point return mode:
The system is started up and stopped by performing AND for external signals and signals via ladder (type 2).
svof Error correction

# Items Details Setting range (unit)
1066 JOG_HP Select JOG activation (+) device
Specify the number of the device that inputs +JOG activation signals. The device type is specified by "#1071 JOG_D". The effective range of set values vary depending on the device type. A value outside of the effective range is invalid if specified. (Note) The setting range of this parameter has been
X: 0000 to 03FF
expanded on the software Ver.D0 and later.
1067 JOG_HN Select JOG activation (−) device
Specify the number of the device that inputs -JOG activation signals. The device type is specified by "#1071 JOG_D". The effective range of set values vary depending on the device type. A value outside of the effective range is invalid if specified. (Note) The setting range of this parameter has been
X: 0000 to 03FF
expanded on the software Ver.D0 and later.
slavno Slave axis number
Specify the axis number of a slave axis to be synchronized. The axis number is an NC number excluding the spindle and PLC axis. Two or more slave axes cannot be set up for one master axis. This parameter "slavno" cannot be set up for a slave axis. A multiple part system cannot be set up so that the relation between the master and slave axes extends over a part system.
no_dsp Axis with no
Set up an axis that displays no counter. This option is valid on the counter display screen (e.g. POSITION screen).
1070 axoff Axis removal
Define an axis that enables axis removal control. 0: Disables axis removal. 1: Enables axis removal
Specify the number of the device that inputs ±JOG activation signals.
activation signal device name
parameters has been expanded on the software Ver.D0 and later.
(decimal) · (decimal) · counter display

# Items Details Setting range (unit)
1073 I_Absm Initial absolute value
Specify the absolute value/incremental value mode for when the power is turned on or reset.
1074 l_Sync Initial synchronous feed
Specify the feedrate specification mode for when the power is turned on or reset.
1075 I_G00 Initial G00 Specify the linear command mode for when the power is turned on or reset.
1076 Abslnc (For L system only)
The absolute value/incremental commands can be issued by using the absolute value address and incremental value address for the same axis.
1077 radius Incremental command for diameter specification axis
Specify if the diameter specification axis’ ("#1019 dia" is set to 1) incremental value command uses the diameter value or radius value
1078 Decpt2 Decimal point type 2
Specify the unit of position commands that do not have a decimal point.
1079 F1digt Validate F1 digit
Specify whether to execute the F command with a 1-digit code command or with a direct numerical command.
ABS/INC address

# Items Details Setting range (unit)
1080 Dril_Z (For M system only)
Specify a fixed-cycle boring axis.
1081 Gmac_P Give priority to G code parameter
Specify the G code priority relationship during the macro call with the G command.
1082 Geomet (For L system only)
Geometric Specify the validity of the geometric function. As the designated address code is used exclusively for geometric‚ if "A" or "C" is used for the axis address or 2nd miscellaneous command code‚ "A" that is the axis address may be handled as the geometric’s angle specification. Take special care to the setting of the axis name‚ etc.‚ when using this function.
1084 RadErr Arc error Specify the tolerable error range when a deviation occurs in the end point and center coordinate in the circular command.
0 to 1.000 (mm)
1085 G00Drn G00 dry run Specify whether to apply dry run (feed with manual setting speed instead of command feedrate) to the G00 command.
1086 G0lntp G00 non- interpolation
Specify the G00 movement path type
1087 G96_G0 Constant surface speed control by rapid traverse feed command
Specify how to handle the cycle speed for the G00 command when using the constant surface speed control function.

# Items Details Setting range (unit)
1088 G30SL Disable G30 soft limit
Specify how to handle the soft limit during G30 (2nd reference point return) movement.
1089 Cut_RT Short cut for rotary axis
Specify how to handle the short cut control for the rotary axis ("#1017 rot" is set to 1).
1090 Lin_RT Linear rotary axis
Specify how to handle a command for the rotary axis that exceeds 360 degrees.
applied value will be 60 degrees. 1: For absolute value commands that exceed 360 degrees‚ the axis will move in the same manner as a linear axis.
will pass the 360 degree position and will move to the 60 degree position.
1091 Mpoint Ignore middle point
Specify now to handle the middle point during G28 and G30 reference point return.
1092 Tchg _A Replace tools for additional axis
Specify the movement of the additional axis during tool change position return.
1093 Wmvfin Waiting method between part systems
Specify the method for waiting between part systems. When the movement command is found in the wait command ! block:
1094 Tl_SBK (for L system only)
Select life count for single block
Select whether to count the data units to be used for a single block when using the tool life management II function (lathe system).

# Items Details Setting range (unit)
1095 T0tfof TF output Select how to handle TF for T00 command.
1096 T_Ltyp (For L system only)
Tool life management type
Specify the tool life management type. 1: Life manage- ment type l 2: Life manage- ment type ll
1097 T1digt Tool wear compen- sation number 1-digit command
Specify the No. of digits in the tool wear compensation No. in the T command.
1098 Tlno. Tool length offset number
Specify the No. of digits in the tool length offset No. in the T command.
1099 Treset Cancel tool wear compen- sation amount
Specify how to handle tool compensation vector when resetting system.
0/1 · 0/1 · 0/1

# Items Details Setting range (unit)
1100 Tmove Tool wear compen- sation
Specify the period to perform tool length offset and wear compensation.
0: Compensate when T command is executed. 1: Superimpose and compensate with the movement command in the block where the T command is located. If there is no movement command in the same block‚ compensation will be executed after the movement command is superimposed in the next movement command block. 2: Compensate when the T command is executed. 1: Superimpose and compensate a tool length offset with the movement command in the same block. If there is no movement command in the same block, compensation will be executed after the movement command is superimposed in the next movement command block.
1101 Tabsmv Tool wear compen- sation method
Specify the type of movement command when "#1100 Tmove" is set to 1.
1102 tlm (For L system only)
Manual tool length measuring system
Specify the measurement method for manual tool measurement l.
1103 T_life Validate life management
Select the usage of the tool life management function.
1104 T_Com2 Tool command method 2
Select the command method for when "#1103 T_Life" is set to 1.
0/1

# Items Details Setting range (unit)
1105 T_Sel2 Tool selection method 2
Select the tool selection method for when "#1103 T_Life" is set to 1.
1106 Tcount (For L system only)
Specify the function when address N is omitted when inputting data (G10 L3 command) for tool life manage- ment function ll.
1107 Tllfsc (For L system only)
Split life management display screen
Set up the number of groups to be displayed on the tool life management II (lathe system) screen.
1108 TlrectM (For L system only)
Life manage- ment re-count M code
Set up the M code for tool life management II (lathe system) re-count.
Validate alternate M code
Select the user macro interrupt with the substitute M code.
1110 M96_M M96 alternate M code
Specify an M code to replace M96 when "#1109 subs_M" is set to 1.
3 to 97 (excluding 30)
1111 M97_M M97 alternate M code
Specify an M code to replace M97 when "#1109 subs_M" is set to 1.
Specify the validity conditions for the user macro interrupt signal.
INT_2 Validate interrupt method type 2
Specify the movement after user macro interrupt signal (UIT) input.

# Items Details Setting range (unit)
1114 mcrint Macro argument initialization
Select whether to clear statements other than specified arguments by macro call. Also, select whether to clear local variables by power-on and resetting.
1115 thwait Waiting for thread cutting
Set the queue number during screw thread cutting when the chamfering is not valid.
0 to 99 (Approx. 4 ms.) Standard set value: 4
1116 G30SLM Invalidate soft limit (manual operation)
Enable this function when disabling the soft limit check function from the second to the fourth reference point return by manual operation.
1117 H_sens Handle response switch
Switch the handle response mode when feeding the handle.
1118 mirr_A (For L system only)
Select how to set up the length of tools on facing turret (double-turret mirror image)
Select one of the following two methods.
1119 Tmiron (For L system only)
Select the double-turret mirror image with T command
Select whether to validate the double-turret mirror image with the T command.
TofVal Change macro variable
Specify whether to change the macro variable (tool offset) numbers for shape compensation and wear compensation.

# Items Details Setting range (unit)
1121 edlk_c Edit lock C Specify whether to prohibit editing of program Nos. 9000 to 9999. 0: Editing possible 1: Editing prohibited
pglk_c Program display lock
The display and search of program Nos. 9000 to 9999 can be prohibited. Specify whether to prohibit display and search.
1123 origin Origin zero inhibition
Select whether to use the origin zero function. 0: Use 1: Do not use
1124 ofsfix Fix tool wear compen- sation number
Specify whether to automatically increment the offset No. by 1 with the input or to display the No. as it is in the setting on the tool offset screen.
1125 real_f Actual feedrate display
Specify the feedrate display on the monitor screen. 0: Command speed 1: Real move- ment feedrate
1126 PB_G90 Not used. 0
1127 DPRINT DPRINT alignment
Specify the alignment for printing out with the DPRINT function.
0/1 · 0/1

# Items Details Setting range (unit)
1128 RstVCI Clear variables by resetting
Specify how to handle the common variables when resetting.
During variable 100 sets specifications:
#100 to #149 are cleared. During variable 200 or 300 sets specifications:
#100 to #199 are cleared.
1129 PwrVCl Clear variables by power-on
Specify how to handle the common variables when the power is turned on.
During variable 100 sets specifications:
#100 to #149 are cleared. During variable 200 or 300 sets specifications:
#100 to #199 are cleared.
1130 set_t Display selected tool number
Specify the tool command value display on the POSITION screen.
Fldcc Feed forward filter
Parameter to suppress acceleration changes with a filter when starting acceleration or deceleration. Specify the parameter in bits.
bit1: 7.1 (ms) bit2: 14.2 (ms) bit3: 28.4 (ms) bit4: 56.8 (ms) If bit 1 to bit 4 are all 0 or two or more bits of bit 1 to bit 4 are 1, 3.5 ms is set up.
7 6 5 4 3 2 1 0
1132 CRT CRT brightness control
This parameter adjusts the brightness of the CRT display unit.
–3: Highest luminance (Brightest state) –3: Lowest luminance (Darkest state) Adjust this parameter to an appropriate brightness between –3 and 3. The EL display unit does not have brightness adjustment‚ so setting is not required.

# Items Details Setting range (unit)
1133 ofsmem Select how to set up tool wear compensa- tion screen
Select the number stored by previous setup when selecting the tool wear compensation screen.
1134 LCDneg LCD reverse display
Specify 1 to reverse the display on the 10.4-type monochrome LCD.
1135 unt_nm Unit name Set up a unit name. Set up the unit name with 4 or less characters consisting of both alphabets and numbers. If 0 is set up, the unit name is not displayed.
4 or less characters consisting of both alphabets and numbers
1138 Pnosel Not used. 0
1139 edtype Edit type selection
Set up an edit type.
1140 Mn100 M code number
First number of M code that corresponds to setup number from 100 to 199.
1141 Mn200 M code number
First number of M code that corresponds to setup number from 200 to 299.
1142 Mn300 M code number
First number of M code that corresponds to setup number from 300 to 399.
1143 Mn400 M code number
First number of M code that corresponds to setup number from 400 to 499.
1144 mdlkof MDI setup lock
Select whether to enable MDI setup in non-MDI mode. 0: Disable MDI
0/1 · 0/1/2

# Items Details Setting range (unit)
1145 I_abs Manual ABS parameter
Specify how to handle the absolute position data during automatic handle interrupt.
1146 Sclamp Spindle rotation clamp function
Specify how to handle the spindle rotation clamp function with the G92S command.
1147 smin_V Minimum spindle rotation speed clamp type
Specify the type of spindle min. rotation speed clamp value.
1148 I_G611 Initial high precision
Specify the default mode after power-on or resetting.
1149 cireft Arc decelera- tion speed change
Specify whether to enable deceleration at the arc entrance or exit.
1150 F1dc0 G00 feed forward filter
This parameter is used to filter acceleration changes at the start of rapid acceleration/deceleration. Specify the filters in bit units.
bit1: 7.1 (ms) bit2: 14.2 (ms) bit3: 28.4 (ms) bit4: 56.8 (ms) If bit 1 to bit 4 are all 0 or two or more bits of bit 1 to bit 4 are 1, 3.5 ms is set up.
7 6 5 4 3 2 1 0
G00 feed forward filter
Feed forward filter G00 and G01 independent 0: Common 1: Independent
1151 rstint Reset initial Specify whether to initialize various modals by resetting.

# Items Details Setting range (unit)
1152 I_G20 Initial command unit
Specify whether the default mode after power-on or resetting, inch command or metric command mode.
pdoor Door interlock II (for each part system)
Specify whether to control door interlock II independently for each of the two part systems. When door interlock II is controlled for each part system of the two part systems, part system 1 is connected to SERVO1 of the base I/O unit and part system 2 is connected to SERVO2 of the base I/O unit. C6/C64 unit When the auxiliary axis (MR-J2-CT) is used, connect it to the SERVO2 side (after the spindle). This validates door interlock II of part system 2.
AMP AMP AMP Part system 1
AMP AMP AMP Part system 2
0: Do not use door interlock II independently for each part system. 1: Use door interlock II independently for each part system. When 0 is specified for this parameter, "Signal input device 1 for door interlock II (#1155 DOOR_m)" and "Device number 2 for door interlock II signal input (#1156 DOOR_s) are valid. When 1 is specified, "Signal input device 1 for door interlock II: for each part system (#1511 DOORPm)" and "Signal input device 2 for door interlock II: for each part system (#1512 DOORPs)."
0/1 · unit" of #1226 · 0/1

# Items Details Setting range (unit)
1155 DOOR_m Signal input device 1 for door interlock II
Set up a fixed device number (X??) for door interlock II signal input. A device number from X001 to X3FF can be set up. Device number 000 is invalid. Set up device number 100 when using no fixed device number for door interlock II signal input. (Note) The setting range of this parameter has been
000 to 3FF (hexadecimal)
expanded on the software Ver.D0 and later. Related parameter: "#1154 pdoor" Door interlock II
(for each part system)
1156 DOOR_s Device number 2 for door interlock II signal input
Set up a fixed device number (X??) for door interlock II signal input. (Set up the same value as that of #1155.) (Note) The setting range of this parameter has been
000 to 3FF (hexadecimal)
expanded on the software Ver.D0 and later. Related parameter: "#1154 pdoor" Door interlock II
(for each part system)
1157 F0atrn F0 automatic running
Not used.
1158 F0atno F0 automatic running program
Not used.
1166 fixpro Fixed cycle editing
Select whether to use the edit‚ program list‚ and data input/output functions for the fixed cycle or general program.
1167 e2rom Not used.
1168 test Simulation test
Specify the test mode for the control unit. The test mode does not use reference point return‚ and tests with a hypothetical reference point return completed state. This is limited to test operation of the control unit itself‚ and must not be used when connected to the machine.
0/1

# Items Details Setting range (unit)
Set the name of each part system. This must be set when using the multiple part system. This name is displayed on the screen only when the part systems must be identified. Use a max. of four alphabetic characters or numerals.
A max. of four alphabetic characters or numerals.
1170 M2name Second miscellane- ous code
Set this address code when using the 2nd miscellane- ous command. Set an address with A‚ B and C that is not used with "#1013 axname" or "#1014 incax".
1171 taprov Tap retract override
Set the tap retract override value for the synchronous tap.
1172 tapovr Tap retract override
Set the override value when leaving the tap end point in the synchronous tap cycle. The setting range is 1 to 999‚ and the unit is %. When a value less than 100 is set‚ it will be judged as 100%.
1173 dwlskp G04 skip condition
Specify the skip signal for ending the G04 (dwell) command.
Skip signals Setting SKIP3 SKIP2 SKIP1 SKIP0 0 × 1 × × × { 2 × × { × 3 × × { { 4 × { × × 5 × { × { 6 × { { × 7 × { { { 8 { × × × 9 { × × { 10 { × { × 11 { × { { 12 { { × × 13 { { × { 14 { { { × 15 { Skip when { signal is input.
1174 skip_F G31 skip speed
Specify the feedrate when there is no F command in the program at G31 (skip) command.
1 to 999999 (mm/min)
1169 system name · Part system name

# Items Details Setting range (unit)
1175 1176 1177 1178 1179 1180
skip1 1f 2 2f 3 3f
Specify the skip signal in the G31.1 to G31.3 (multi-step skip) command‚ and the feedrate when there is no F command in the program.
Skip condition:
0 to 15 Skip federate:
Skip signals Setting SKIP3 SKIP2 SKIP1 SKIP0 0 × 1 × × × { 2 × × { × 3 × × { { 4 × { × × 5 × { × { 6 × { { × 7 × { { { 8 { × × × 9 { × × { 10 { × { × 11 { × { { 12 { { × × 13 { { × { 14 { { { × 15 { Skip when { signal is input. Skip signal specified at G31.1 Skip feedrate at G31.1 Skip signal specified at G31.2 Skip feedrate at G31.2 Skip signal specified at G31.3 Skip feedrate at G31.3
1 to 999999 (mm/min)
G31.1 skip condition G31.1 skip speed G31.2 skip condition G31.2 skip speed G31.3 skip condition G31.3 skip speed

# Items Details Setting range (unit)
1181 G96_ax Constant surface speed control
Specify the axis to be targeted for constant surface speed control.
1182 thr_F Thread cutting speed
Set the screw cut up speed when not using chamfering in the thread cutting cycle.
0 to 60000 (mm/min)
1183 clmp_M M code for clamp
Set the M code for C-axis clamp in the hole opening cycle.
1184 clmp_D Dwelling time after output- ting M code for unclamp
Set the dwell time after outputting the M code for C-axis unclamp in the hole opening cycle.
0.000 to 99999.999 (s)
1185 1186 1187 1188 1189
spd_F1 spd_F2 spd_F3 spd_F4 spd_F5
F1 digit feedrate F1 F2 F3 F4 F5
Specify the feedrate for the F command in the F1-digit command ("#1079 F1 digit" is set to 1). Feedrate when F1 is issued (mm/min) Feedrate when F2 is issued (mm/min) Feedrate when F3 is issued (mm/min) Feedrate when F4 is issued (mm/min) Feedrate when F5 is issued (mm/min)
1 to 1000000 (mm/min)
s_xcnt (For L system only)
s_angl (For L system only)
Specify the inclination angle α of the oblique coordinate X' axis from the orthogonal coordinate system's X axis.
–80.000 to 80.000 (degree)
s_zrmv (For L system only)
Compensati on at reference point return
Specify whether to perform compensation for the base axis corresponding to the inclined axis at reference point return.
Validate inclined-axis control · Inclination angle · 0/1

# Items Details Setting range (unit)
1193 inpos Validate in-position check
Specify the deceleration confirmation method for the positioning command.
1194 H_acdc Time constant 0 for handle feed
Specify the time constant for the manual handle feed.
1195 1196 1197 1198
Mmac Smac Tmac M2mac
Macro call for:
Specify the user macro M‚ S or T command macro call out. Macro call out with M command Macro call out with S command Macro call out with T command Macro call out with 2nd miscellaneous command
M command S command T command Second miscellaneous code
Select the initial condition of spindle control after power is turned on.
Set up acceleration and deceleration types when a rapid traverse command is issued
celeration and deceleration with inclination angle constant G0
Set up acceleration and deceleration types when a liner interpolation command is issued.
celeration and deceleration with inclination constant G1
1202 mirofs (For L system only)
Distance between facing turrets
Set up the distance between tools (noses) (between turrets).
0 to 99999.999 (mm)

# Items Details Setting range (unit)
1203 TmirS1 (For L system only)
Select turrets for double-turret mirror image with T command
Set up turrets for double-turret mirror image with the T command that corresponds to tool numbers 1 to 32.
1204 TmirS2 (For L system only)
Select turrets for double-turret mirror image with T command
Set up turrets for double-turret mirror image with the T command that corresponds to tool numbers 33 to 64.
1205 G0bdcc Acceleration and deceleration before G0 interpolation
1206 G1bF Maximum speed
Set up a cutting feedrate when selecting acceleration and deceleration before interpolation.
1 to 1000000 (mm/min)
1207 G1btL Time constant
Set up a cutting feed time constant when selecting acceleration and deceleration before interpolation.
1 to 5000 (ms)
1208 RCK Arc radius error compen- sation factor
An arc radius error compensation amount can be increased and decreased from −60.0 to 20.0%.
1209 cirdcc Arc deceleration speed
Specify the deceleration speed at the arc entrance or exit.
1 to 1000000 (mm/min)

# Items Details Setting range (unit)
1210 RstGmd Modal G code reset
Specify whether to initialize each G code group modal and the H and D codes when the system is reset. Specify the initialization items in bit correspondence. 0. Initialize. 1: Do not initialize. M system
Specify a hexadecimal number.
0 Group 1 Move G modal 1 Group 2 Flat selection modal 2 Group 3 Absolute/increment command modal 3 4 Group 5 Feed G modal 5 Group 6 Inch/metric modal 6 Group 7 Radius compensation modal 7 Group 8 Length compensation modal 8 9 Group 10 Fixed cycle return command modal A B Group 12 Workpiece coordinate system modal C Group 13 Cut modal D E F
10 Group 17 Constant surface speed control command modal 11 12 Group 19 G command mirror modal 13 Group 20 Spindle 2 control modal 14 15 16 17 18 H, D codes 19 1A 1B 1C 1D 1E 1F
The H code indicates the tool length offset number, and the D code indicates the tool radius compensation number. When bit 18 is set to on, the H and D codes and group 8 G modal area retained. When bit 7 is set to on, the H code and group 8 G modal are retained.

# Items Details Setting range (unit)
1210 RstGmd Modal G code reset
Specify a hexadecimal number.
0 Group 1 Move G modal 1 Group 2 Flat selection modal 2 Group 3 Absolute/increment command modal 3 Group 4 Barrier check modal 4 Group 5 Feed G modal 5 Group 6 Inch/metric modal 6 Group 7 Nose radius compensation modal 7 8 9 Group 10 Fixed cycle return command modal A B Group 12 Workpiece coordinate system modal C Group 13 Cut modal D E F
10 Group 17 Constant surface speed control command modal 11 Group 18 Balance cut 12 13 Group 20 Spindle 2 control modal 14 Group 15 Double-turret mirror image 15 16 17 18 19 1A 1B 1C 1D 1E 1F
1211 FHtyp Feed hold stop type
Specify the type of the external signal used for feed hold.
1212 FHno Feed hold external signal device
Specify the number (X??) of the device used to input the feed hold signal. (Note) The setting range of this parameter has been
000 to 3FF (hexadecimal)
expanded on the software Ver.D0 and later.
1216 extdcc External deceleration level
Use an upper limit value at the feedrate indicated when validating external deceleration signals.
1 to 1000000 (mm/min)
1217 aux01 Not used.
L system

# Items Details Setting range (unit)
Specify a parameter input/output format.
Specify the R register that contains the tool number used for automatic calculation when measuring the coordinate offset of an external work piece.
Parameter I/O II spindle specification address
Specify the spindle specification address of parameter I/O type II.
type II ("#1218 aux02/bit 3" is 1).
Set No. valid when program input
Specify which program No. is selected when inputting operation using “#1 MAIN PROGRAM” in Data I/O screen.
Input by program overwrite
When inputting the machining program in the "Data input" screen, select one of the following options when the input program has already been registered:
Stop high- speed PC monitoring function
Set 1 to disable the function that stops the system when the high-speed processing time is extended. Disable the monitoring function only as a temporary measure.
Improve skip coordinate accuracy
Reserved for the system. 0

# Items Details Setting range (unit)
Time constant setting changeover for software acceleration/ deceleration

# Items Details Setting range (unit)
(Continued from the previous page) 1: Accelerating time is obtained by G0tL+G0t1 (G1tL+G1t1). When the acceleration/deceleration before G00 interpolation and the software acceleration/deceleration are used one together, if the same time is set to S-curve filter time (#1131 F1dcc) and the software acceleration/deceleration 2nd step time constant (#2005 G0t1), the G00 acceleration can be obtained equals as G28/G30.
and later.
1220 aux04 (bit 0) (For L system only)
Tool life check timing selection
Specify the life check standard applicable when the use count is incremented in tool life management II.

# Items Details Setting range (unit)
Validity of space code in comment
Validate or invalidate the space code described in the comment statements in the machining program in edit operation with the custom display.
1221 aux05 Not used.
Not used. 0
Not used. 0
Enable/disable setup parameter lock
Specify whether to enable the setup parameter lock function.
Not used. 0
Not used. 0
Not used. 0
Not used. 0
Not used. 0
Not used. 0
Not used. 0
Cancel synchronous tap (,S) retract
Specify a synchronous tap method.
1224 aux08 Unusable. Set 0 for this option.
Enable/disable spindle rotation clamp
Specify whether to enable spindle rotation clamp by the spindle rotation clamp command (G92S, Q) instead of the spindle rotation command (R3210) specified by the user ladder.

# Items Details Setting range (unit)
Tool compen- sation data for external workpiece coordinate offset measurement
Select the tool offset data to be used for external workpiece coordinate offset measurement.
Optional block skip type
Specify whether to enable optional block skipping in the middle of a block.
Single block stop timing
Specify the time at which the single block signal is activated.
Not used. 0
S command during constant surface speed
Specify whether to output a strobe signal when the S command is issued in constant surface speed mode.
Dog/OT signal arbitrary assignment valid
Specify whether to enable the arbitrary allocation parameter for the origin dog and H/W OT.

# Items Details Setting range (unit)
Setup and display unit
Specify the unit to be used as the setup/display unit or handle feed unit, the command unit or internal unit.
mode (0 is set in "#1041 I_inch"). The internal unit is always used in initial inch mode (1 is set in "#1041 I_inch"). (Note 2) This parameter is validated immediately after
it is set. (Note 3) If addition setting is performed for tool and
workpiece offset data with the command unit being inch and internal unit being mm, an error may be generated. Related parameter: #1152 I_G20 (Initial command
Shorten JOG stop time
Specify whether to shorten the JOG stop time.
Select PLC signal or spindle feedrate attained
Set up this option when disabling the cutting start interlock by spindle feedrate attained.
Select H or D code
Set up this option to validate the data that is set up on the tool life management screen when issuing the H99 or D99 command.

# Items Details Setting range (unit)
Measures against tool setter chattering
Select a condition where a relieving operation completes after measurement with tools.
Absolute coordinate switching (nose R)
Select whether to display a nose position or coordinate value with the absolute coordinate counter.
Specify whether to simply check the program address when the machining program is executed.
Spindle rotation speed clamp
Specify whether to clamp the rotation speed in constant surface speed mode when the spindle rotation clamp command is issued.
Not used. 0
Switch the range of tool life data to be input
Set up the range of tool life data to be input or compared.

# Items Details Setting range (unit)
Switch coordinate value screen
Set up this option to switch the coordinate value screen.
Switch offset and parameter screen
Set up this option to switch the offset and parameter screen to the parameter screen.
Switch data protection in data transmission mode
Set up the range of data protection in data transmission mode.
Select whether to specify the nose R compensation by shape or wear number.
Select operation error or stop code
Specify both block cutting start interlock and cutting start interlock as the operation error or stop code.
Select constant surface speed coordinates
Select constant surface speed coordinates.
Switch relative values displayed
Protection with manual value command
Set up this option to protect a manual value command.
Accurate thread cutting E

# Items Details Setting range (unit)
Radius compen- sation type B (For M system only)
Nose R compen- sation type B (For L system only)
Initial constant surface speed
Select an operation when the operation start point cannot be found while moving the next block of G117.
Select a grid type to be displayed on the servo monitor screen during dog type reference point return.
1230 set02 Not used.
1231 set03 Not used.
1232 set04 Not used.
1233 set05 Not used.

# Items Details Setting range (unit)
1234 set06 Not used.
1235 set07 Not used.
Manual rotation axis feedrate unit
Select the unit of manual rotation axis feedrate.
Set up this function to use the external workpiece coordinates by shifting them to the Z axis.
shift) has been reversed, do not measure those external workpiece offsets. However, the external workpiece offsets can be measured by tool pre-setter.
set10 Not used.
using MDS-B-SP and later. However, if the system structure needs the mechanical gears for spindles, set “0”.
Select the handle input pulse.
Megatorque motor handle feed magnifi- cation
Select the magnification of megatorque motor handle 1 pulse.

# Items Details Setting range (unit)
Select the command format.
ext02 Not used.
G code type Select the G code type. This parameter is valid when 1 is set in "#1265 ext01 bit 0 (command format)".
ext04 Not used.
ext05 Not used.
ext06 Not used.
Select the type of mirror image operation. Not applied to this CNC.
Address specifying fixed-cycle repetition count (For M system only)
Specify the address that specifies the fixed-cycle repetition count. Not applied to this CNC.
Specify the unit to be used if a thread cutting read command contains on decimal point. Not applied to this CNC.

# Items Details Setting range (unit)
G-code group for unidirectiona l positioning (for M system only)
Specify the G-code group for unidirectional positioning. Not applied to this CNC.
”#8209 G60 SHIFT”(Set the last positioning direction and distance for each axis applicable when the unidirectional positioning command is issued.)
Operation by independent G40 command
Specify the mode of canceling tool radius compensation vector by the independent G40 command. Not applied to this CNC.
Cut start position (For L system only)
Specify the position from where cutting begins in a composite-type fixed cycle for lathe.
Nose R compensa- tion (For L system only)
Specify whether to apply nose R compensation to shapes in a rough cutting cycle.

# Items Details Setting range (unit)
Cut amount (For L system only)
Specify the operation to be performed when the program-specified cut amount exceeds the cut amount of the final shaping program.
M function synchronous tap cycle
Specify whether to enable the M function synchronous tap cycle.
ext09 Not used.
ext10 Not used.
ext11 Not used.
ext12 Not used.
Tool life management II count type 2
Specify how and when the mount or use count is incremented in tool life management II.
ext14 Not used.
ext15 Not used.
ext16 Not used.
ext17 Not used.
ext18 Not used.
ext19 Not used.
ext20 Not used.
ext21 Not used.

# Items Details Setting range (unit)
ext22 Not used.
Select the mode of displaying the workpiece coordinate counter.



# Items Details Setting range (unit)
1301 nrfchk Origin neighboring check method
Select the high-speed check method of the origin neighboring signal.
1501 polyax (For L system only)
Rotational tool axis number
Specify the number of the rotational tool axis (servo axis) used for polygonal machining (G51.1). Specify 0 when polygonal machining is not performed. A value exceeding the base specification parameter "#1002 axisno" cannot be specified. This parameter is valid when the G code system is 6 or 7 (7 or 8 is set in base specification parameter "#1037 cmdtyp").
0 to controlled axis number
1505 ckref2 Second reference point return check
Specify the trigger for a check at the specified position in manual second reference point return mode.
1510 DOOR_H Shorten door interlock II axis stop time
Specify whether to shorten the time during which the axis is stopped when the door is opened.
ladder, the conventional axis stop time is used.
1511 DOORPm Signal input device 1 for door interlock II: for each part system
Specify the fixed device number (X??) for door interlock II signal input for each part system. A device number from X001 to X3FF can be specified. Device number 000 is invalid. Specify device number 100 when using no fixed device number for door interlock II signal input. (Note) The setting range of this parameter has been
000 to 3FF (hexadecimal)
expanded on the software Ver.D0 and later. Related parameter: #1154 pdoor (Door interlock II for
1512 DOORPs Signal input device 2 for door interlock II: for each part system
Specify the fixed device number (X??) for door interlock II signal input for each part system. (Specify the same value as that of #1155.) (Note) The setting range of this parameter has been
000 to 3FF (hexadecimal)
expanded on the software Ver.D0 and later. Related parameter: #1154 pdoor (Door interlock II for


+99999999 1802 Macc_c Acceleration check at middle speed -99999999 to
+99999999 1803 Lacc_c Acceleration check at low speed -99999999 to
+99999999 1811 Hcof_A X-axis high acceleration coefficient β -99999999 to
+99999999 1812 Hcof_B X-axis high acceleration coefficient α -99999999 to
+99999999 1813 Mcof_A X-axis middle acceleration coefficient β -99999999 to
+99999999 1814 Mcof_B X-axis middle acceleration coefficient α -99999999 to
+99999999 1815 Lcof_A X-axis low acceleration coefficient β -99999999 to
+99999999 1816 Lcof_B X-axis low acceleration coefficient α -99999999 to
+99999999 1817 mag_C X-axis change magnification θ [%] Set 0 when no compensation or change is executed.
1821 Hcof_A Y-axis high acceleration coefficient β -99999999 to
+99999999 1812 Hcof_B Y-axis high acceleration coefficient α -99999999 to
+99999999 1813 Mcof_A Y-axis middle acceleration coefficient β -99999999 to
+99999999 1814 Mcof_B Y-axis middle acceleration coefficient α -99999999 to
+99999999 1815 Lcof_A Y-axis low acceleration coefficient β -99999999 to
+99999999 1816 Lcof_B Y-axis low acceleration coefficient α -99999999 to
+99999999 1817 mag_C Y-axis change magnification θ [%] Set 0 when no compensation or change is executed.

# Items Details Setting range (unit)
station addr Set up a station address number (the NC is the n-th slave station).
Din size Set up the size of the data to be transferred from the PC to the NC (from the master station to the slave station) in bytes (8 points).
0 to 32 (bytes (8 bits))
Dout size Set up the size of the data to be transferred from the NC to the PC (from the slave station to the master station) in bytes (8 points).
0 to 32 (bytes (8 bits))
data length Set up the data length of a character. 0 to 2 : 7 bits 3 : 8 bits 1905 (PR)
Clock: 6/10 MHz 0: 38400 / 57600 1: 19200 / 28800 2: 9600 / 14400 3: 4800 / 7200 4: 2400 / 3600 5: 1200 / 1800 6: 600 / 900 (bps) 1906 (PR)
baud rate Set up a data transfer rate. The transfer rate differs according to operation clock rates.
stop bit Set up the stop bit length. 0 and 1: 1 bit 2 and 3: 2 bits 1907 (PR)
parity check Select whether to make a parity check. 0: Invalid 1: Valid 1908 (PR)
even parity Select the odd or even parity bit. If no parity check is specified, this parameter is ignored.
Tout (ini) (ini) specifies a time-out from when the connection check sequence finishes to when the first usual sequence (input) finishes.
0 to 999 (0.1 s)
(run) (run) specifies a time-out from when the NC (slave station) outputs usual sequence data to when the next usual sequence data is input. If the time-out is exceeded, an emergency stop occurs and the system waits for the preparation sequence to start. If the set value is 0, no time-out occurs or no communi- cation stop can be detected.
clock select Select an operation cycle. 0: 6 MHz 1: 10 MHz 1926 (PR)
IP address Set NC's IP address.
Set these according to connection environ- ment's network regulations.
Subnet mask Set sub-net mask.
Gateway address Designate gateway IP address.

# Items Details Setting range (unit)
Port number Set the HMI connection port No. (Set the default value 64758 unless particularly required.)
Speed 10M/auto Set the communication rate.
IP address(2) Set NC's IP address. Set for the card mounted on the 2nd channel when 2-channel connection is used on the Ethernet communication. (Note1) 1932 (PR)
Set these according to connection environ- ment's network regulations.
Subnet mask(2) Set sub-net mask. Set for the card mounted on the 2nd channel when 2-channel connection is used on the Ethernet communication. (Note1)
Port number(2) Set the HMI connection port No. (Set the default value 64758 unless particularly required.) Set for the card mounted on the 2nd channel when 2-channel connection is used on the Ethernet communication. (Note1)
Speed(2) 10M/auto Set the communication rate.
(Note1) When two Ethernet cards are mounted, make sure not to use IP address on the same network
IDs. The cards are regarded as “same network IDs” when the area masked (validated) by “Subnet mask” parameter is the same as another.
0/1 · 0/1

# Items Details Setting range (unit)
21025 SmpDelay Set up a sampling time after an alarm occurs. 0 to 3000 (ms) 21028 ed_mess Set up an edit type.
21029 NCname Use this to display the NC unit name on the CE terminal screen.
8 or less alphanumeric characters 21030 AlmHold (h) Set the time to delete sampling data automatically after an alarm occurs. If 0 is set, the alarm will not be deleted automatically.
0 to 9999 (h)
21031 UnitMax Set the number of connected control units when setting and displaying several NC control units with one terminal using the multiple NC common display function. Up to 15 NC control units can be connected. The default value is "0", so if the setting is not changed, it will be interpreted that 1 control unit is connected. (The setting values "0" and "1" are handled in the same manner.)
21032 UnitNum Set the control unit's station No. when setting and displaying several NC control units with one terminal using the multiple NC common display function. "0" is the first station No. and "14" is the last station No. Make sure that the stations are not set in duplicate.
21033 KeyCtrlLmt Acquisition of the key operation rights are limited.
21034 ReMonDisp The remote monitor tool displays are limited.
display will not appear as soon as this parameter is set.
21049 SPname Designate the spindle No. selected for the G43.1 modal in each part system.
0/1

# Items Details Setting range (unit)
PLC axis rapid traverse mode acceleration/ deceleration type
Select the PLC axis rapid traverse mode acceleration/ deceleration type. (This is compatible from software version C0 and higher.)
peripheral axes (MC1K I/F) is used.
PLC axis cutting feed mode acceleration/ deceleration type /Peripheral axis (MC1K I/F) acceleration/ deceleration type
Select the PLC axis cutting feed mode acceleration/ deceleration type. (This is compatible from software version C0 and higher.)
acceleration/deceleration type when the peripheral axes are used. (This is compatible from software version C0 and higher.)
Circular command block overlap valid
Validates the block overlap at the circular command. (This is compatible from software version C1 and higher.)
G31 automatic acceleration/ deceleration
Validates dry run, override and automatic acceleration/ deceleration for the G31 (skip) command. (This is compatible from software version C1 and higher.)
Reserved for system. 0
Reserved for system. 0

# Items Details Setting range (unit)
Servo parameter 100-point compliance
External search time-out valid
RIO communi- cation interruption alarm invalid
Reserved for system. 0
Amp S/W automatic download valid (only C64T)
Specify whether to perform or not the automatic download of the amp software when the power is turned ON.
0/1 (Standard:0)
Select the sampling mode. (This is compatible from software version D0 and higher.)



After setting up the parameter (PR) listed in the table, turn off the NC power. To validate the parameter, turn on the power again.
# Items Details Setting range
(unit) 2001 rapid Rapid traverse feedrate
Set up the rapid traverse feedrate for each axis. The maximum value to be set differs with mechanical systems.
1 to 1000000 (mm/min)
2002 clamp Cutting feedrate for clamp function
Define the maximum cutting feedrate for each axis. Even if the feedrate in G01 exceeds this value‚ the clamp will be applied at this feedrate.
1 to 1000000 (mm/min)
smgst Acceleration and deceler- ation modes
Specify acceleration and deceleration control modes.
Specify the modes in hexadecimal notation.
F E D C B A 9 8 7 6 5 4 3 2 1 0
OT3 OT2 OT1 C3 C1 LC R3 R1 LR
(Note) Set 0 in null bits. Rapid traverse feed acceleration and deceleration types
deceleration (Note) Designate “F” with bits 0 to 3 for rapid traverse
with acceleration/deceleration by software. Note that the acceleration/deceleration by software will not applied on such case as follows;
(1) When the parameters are set as “#1205
G0bdcc” = “1” (acc/dec before G00 is valid) and “#1086 G0Intp” = “0” (G00 non-interpolation invalid), the acceleration/deceleration before interpolation will be applied to the following operation. (a) Travel by G00 command (b) Travel from G28/G30 command start
point to the intermediate point (c) Travel from G29 command reference
to the intermediate point (Continued on the next page)

# Items Details Setting range
(unit) (Continued from the previous page) Cutting feed acceleration and deceleration types
deceleration (Note) Designate “F” with bits 4 to 7 for cutting feed
with acceleration/deceleration by software. Note that the acceleration/deceleration by software will not applied on such case as follows;
(1) AS for G01/G02/G03 command during
G61.1 modal, s-curve acceleration/ deceleration before interpolation is applied to. (2) Linear acceleration/deceleration is applied
to the cutting feed during synchronous tapping.

R1 > R3 when both R1 and R3 contain 1.
(Continued on the next page)
Type OT2 OT3 Linear deceleration 0 0 Position loop step stop 1 0 Speed loop step stop 0 1 Position loop step stop 1 1 OT1 0 Deceleration by G0t1 1 Deceleration by 2 × G0t1
patterns>

# Items Details Setting range (unit)
(Continued from the previous page)
OT1 is valid under the following conditions (valid for dog type reference point return): Stop type: Linear deceleration Acceleration mode: Exponential Deceleration mode: Linear
2004 G0tL G0 time constant (linear)
Set up a linear control time constant for rapid traverse acceleration and deceleration. The time constant is validated when LR (rapid traverse feed with linear acceleration or deceleration) or F (acceleration or deceleration by software) is selected in acceleration or deceleration mode "#2003 smgst."
1 to 4000 (ms)

# Items Details Setting range (unit)
2005 G0t1 G0 time constant (primary delay) Second-step time constant for acceleration and deceleration by software
Set up a primary-delay time constant for rapid traverse acceleration and deceleration. The time constant is validated when R1 (rapid traverse feed with primary delay) or R3 (exponential acceleration and linear deceleration) is selected in acceleration or deceleration mode "#2003 smgst." When acceleration or deceleration by software is selected, the second-step time constant is used.
1 to 5000 (ms)
<Rapid traverse feed with primary delay>
<Rapid traverse feed with exponential acceleration and linear deceleration>
2006 G0t2 Not used. 0

# Items Details Setting range (unit)
2007 G1tL G1 time constant (linear)
Set up a linear control time constant for cutting acceleration and deceleration. The time constant is validated when LC (cutting feed with linear acceleration and deceleration) or F (acceleration and deceleration by software) is selected in acceleration or deceleration mode "#2003 smgst."
1 to 4000 (ms)
2008 G1t1 G1 time constant (primary delay) Second-step time constant for acceleration and deceleration by software
Set up the primary delay time constant for cutting acceleration and deceleration. The time constant is validated when C1 (cutting feed with the primary delay) or C3 (cutting feed with exponential acceleration and linear deceleration) is selected in acceleration or deceleration mode "#2003 smgst." When acceleration or deceleration by software is selected, the second stage time constant is used.
1 to 5000 (ms)
<Cutting feed with primary delay>
<Cutting feed with exponential acceleration and linear deceleration>
2009 G1t2 Not used.

# Items Details Setting range (unit)
2010 fwd_g Feed forward gain
Set up a feed forward gain for pre-interpolation acceleration and deceleration. The larger the set value, the smaller the theoretical control error will be. However, if a mechanical vibration occurs, the set value must be reduced.
2011 G0back G0 backlash Set up the backlash compensation amount when the direction is reversed with the movement command in rapid traverse feed mode or in manual mode.
−9999 to 9999 (command unit / 2)
2012 G1back G1 backlash Set up the backlash compensation amount when the direction is reversed with the movement command in cutting mode.
−9999 to 9999 (command unit / 2)
2013 2014 0T − 0T + Soft limit I − Soft limit I +
Set up a soft limit area with reference to the zero point of the basic mechanical coordinates. For the movable area of stored stroke limit 1, set the coordinate in the negative direction in #2013 and the coordinate in the positive direction in #2014. To narrow the available range in actual use, use the parameters #8204 OT- and #8205 OT+. (Note) When the same value (other than 0) is set in
±99999.999 (mm)
#2013 and #2014, this function is disabled.
OT+(Z)
OT-(X)
OT+(X)
OT-(Z)
2015 t1m1− Negative direction sensor of tool setter or TLM standard length
Set up a sensor position in the negative direction when using the tool setter. When the TLM is used, set up the distance of a tool replacement point (reference point) for measuring the tool length from the zero point to the measurement reference point (surface).
±99999.999 (mm)
2016 t1m1+ Positive direction sensor of tool setter
Set up the sensor position in the positive direction when using the tool setter.
±99999.999 (mm)
Basic machine coordinate · Movable area

# Items Details Setting range (unit)
2017 tap_g Axis servo gain
Set the position loop gain in the synchronous tap cycle. The setting range is 0.25 to 200.00rad/s‚ in 0.25 increment units. The standard setting is 10.
0.25 to 200.00 (rad/s)
2018 no_srv Operation with no servo control
Set when performing test operation without connecting the drive amplifier and motor.
2019 revnum Retract steps Set up the steps required for retracting to the reference point for each axis.
2020 o_chkp Spindle orientation completion check during second reference point return
Set up the distance from the second reference point to the position for checking that the spindle orientation has completed during second reference point return. If the set value is 0, the above check is omitted.
0 to 99999.999 (mm)
2021 out_f Maximum speed outside soft limit range
Set up the maximum speed outside the soft limit range. 0 to 1000000
2022 G30SLX Validate soft limit (automatic and manual)
Set up this function to disable a soft limit check during the second to the fourth reference points return in both automatic and manual operation modes.
2023 ozfmin Set up ATC speed lower limit
Set up the minimum speed outside the soft limit range during the second to the fourth reference points return in both automatic and manual operation modes.
2024 synerr Allowable error
Set up the following for the master axis: the maximum synchronization error that is allowed to check for synchronization errors. When 0 is set up, the error check is not carried out.
0 to 99999.999 (mm)
0/1 · 0/1

After setting up the parameter (PR) listed in the table, turn off the NC power. To validate the parameter, turn on the power again.
# Items Details Setting range (unit)
2025 G28rap G28 rapid traverse feedrate
Set up a rapid traverse feedrate for dog type reference point return command.
1 to 1000000 (mm/min)
2026 G28crp G28 approach speed
Set up the speed of approach to the reference point in the reference point return command. This speed is attained after the system stops with deceleration by dog detection. (Note) The G28 approach speed unit is 10°/min only
1 to 60000 (mm/min)
when using the spindle/C-axis with the Z-phase type encoder for the reference point return type ("#1226 aux10" bit3 = 1). Note that this unit is applied to both micrometric and sub-micrometric specifications.
2027 G28sft Reference point shift distance
Set up the distance from the electrical zero-point detection position to the actual machine reference point during reference point return.
0 to 65535 (µm)
2028 grmask Grid mask amount
Set up a distance where the grid point is ignored when near-point dog OFF signals are close to that grid point during reference point return.
0 to 65535 (µm) Even for the specifications in sub-micrometric system, set up the value in units of µm.
Grid mask setup distance
The grid mask is valid by one grid.
2029 grspc Grid interval Set up a detector grid interval. Generally, set up the value equal to the ball screw pitch. However, if the detector grid interval is not equal to the screw pitch when measured with a linear scale, set up the detector grid interval. To reduce the grid interval, use its divisors. To use 0.001 mm as minimum setup units, set up the negative value. Example) Setup value
−32767 to 999 (mm)
−1 → 1.000 mm (°) −1 → 0.001 mm (°) Even when the specifications in sub-micrometrics are used, 0.001 mm is specified for the minimum setup units.
Near-point dog

# Items Details Setting range (unit)
dir (−) Reference point direction (−)
Set which side of the near-point dog the reference point is at during reference point return.
Direction in which zero point is established as viewed from the near-point dog
2031 noref Axis without reference point
Specify the axis that does not have a reference point. Before automatic operation starts, reference point return is not required.
2032 nochk Whether reference point return is completed not checked
The absolute and incremental commands can be executed even if dog type (or Z phase pulse system) reference point return is not completed. Specify whether to check that the reference point return is completed.
2037 2038 2039 2040
G53ofs #2_rfp #3_rfp #4_rfp
Reference point #1 to #4
Set up the position of the first, second, third, and fourth reference points from the zero point of the basic mechanical coordinates.
±999999.999 (mm)
M Basic machine coordinates

# Items Details Setting range (unit)
type Absolute position detection method
Specify the absolute position zero point alignment method.
2050 absdir Base point of Z direction
Set the direction of the grid point just before the marked point (of the detector) when using marked point alignment method.
2051 check Check Set the tolerable range for the movement amount (deviation amount) when the power is turned off.
0 to 99999.999 (mm)
2052 absg28 Width compared by G28
Specify the position comparison when executing G28 or G30. The comparison results set the tolerable range.
0 to 65535 (0.5 µm)
2053 absm02 Width compared by M02
Specify the position comparison when executing M02 or M30. The comparison results set the tolerable range.
0 to 65535 (µm)

# Items Details Setting range (unit)
2054 clpush Current limit (%)
Set up the current limit value for the initial setting when detecting an absolute position with a dog-less system. The setup value is the ratio of the current limit value to the rated value.
2055 pushf Push speed Set the feedrate for the automatic initial setting during stopper method.
1 to 999 (mm/min)
2056 aproch Approach Set the approach distance for the automatic initial setting in the stopper method. Approach distance: After pushing onto the machine
0 to 999.999 (mm)
stopper once‚ the tool returns this distance‚ and then pushes again. When set to 0‚ the reference point coordinates set in "#2037 G53ofs" will be used as the approach start position.
2057 nrefp Near zero point +
Set the width where the near-reference-point signal is output. (Positive direction width) When set to 0‚ the width is equivalent to the grid width setting.
0 to 32.767 (mm)
2058 nrefn Near zero point −
Set the width where the near-reference-point signal is output. (Negative direction width) When set to 0‚ the width is equivalent to the grid width setting.
0 to 32.767 (mm)
2059 zerbas Select zero point parameter and reference point
Specify the position to be the zero point coordinate during absolute position initial setting.
0/1

# Items Details Setting range (unit)
2061 OT_1B− Soft limit IB− Set up the coordinates of the lower limit of the inhibited area of stored stroke limit IB. Specify a value in the basic machine coordinates system. If the same value (other than 0) with the same sign as that of "#2062 OT_IB−" is specified, the stored stroke limit IB function is disabled.
±99999.999 (mm)
2062 OT_1B+ Soft limit IB+ Set up the coordinates of the upper limit of the inhibited area of stored stroke limit IB. Specify a value in the basic machine coordinates system.
±99999.999 (mm)
2063 OT_1B type
Soft limit IB type
Select OT_IB or OT_IC in which OT_IB+/− is used in stored stroke limit I.
2068 G0fwdg G00 feed forward gain
Specify the feed forward gain applicable to acceleration/deceleration before G00 interpolation. The greater the set value, the shorter the positioning time during in-position checking. If machine vibration occurs, decrease the set value.
2069 Rcoeff Axis arc radius error correction efficient
The amount of arc radius error correction can be increased or decreased between -100% to +100% for each axis.
div_RT Rotational axis division count
Specify the number of divisions of one turn of the rotational axis for purpose of control.
(Example) When 36 is set, one turn is supposed to
be 36.000. (Note) When 0 is set, the normal rotational axis
(360.000 degrees for one turn) is assumed. * If this parameter is changed when the absolute position detection specification is used, absolute position data is lost. Initialization must be performed again.
0/1/2

# Items Details Setting range (unit)
2073 zrn_dog Origin dog Random assignment device
When it is desired to assign the origin dog signal to a position other than the fixed device, specify the input device in this parameter. (Note1) This parameter is valid when 1 is set in #1226
000 to 3FF (HEX)
aux10 bit 5. (Note2) When this parameter is valid, do not set the
same device number. If the same device number exists, an emergency stop occurs. Note that the device number is not checked for an axis to which a signal that ignores the fixed signal is input. (Note3) The setting range of this parameter has been
expanded on the software Ver.D0 and later.
2074 H/W_OT+ H/W OT+ Random assignment device
When it is desired to assign the OT (+) g signal to a position other than the fixed device, specify the input device in this parameter. (Note1) This parameter is valid when 1 is set in #1226
000 to 3FF (HEX)
aux10 bit 5. (Note2) When this parameter is valid, do not set the
same device number. If the same device number exists, an emergency stop occurs. Note that the device number is not checked for an axis to which a signal that ignores the fixed signal is input. (Note3) The setting range of this parameter has been
expanded on the software Ver.D0 and later.
2075 H/W_OT- H/W OT- Random assignment device
When it is desired to assign the OT (-) g signal to a position other than the fixed device, specify the input device in this parameter. (Note1) This parameter is valid when 1 is set in #1226
000 to 3FF (HEX)
aux10 bit 5. (Note2) When this parameter is valid, do not set the
same device number. If the same device number exists, an emergency stop occurs. Note that the device number is not checked for an axis to which a signal that ignores the fixed signal is input. (Note3) The setting range of this parameter has been
expanded on the software Ver.D0 and later.
2076 index_x Index table indexing axis
Specify the index table indexing axis.
parameter is invalid if specified for the PLC axis.
0/1

# Items Details Setting range (unit)
22011 bscmp− Offset compensa- tion position
Specify the coordinates on the machine basic coordinates where the compensation is carried out by the offset amount.
±99999.999
22012 bscmp+ Max. compensa- tion position
Specify the coordinates on the machine basic coordinates where the compensation is carried out by the max. offset amount.
±99999.999
(Note) The positional relation of either #22011 and #22012 can be on the minus side.

The parameters can be changed from any screen. The valid servo parameters will differ according to the motor type. The setting values and meanings may also differ. Follow the correspondence table given below, and set the correct parameters. Refer to each Instruction Manual or the following manuals for details on each motor.
MELDAS AC Servo/ Spindle MDS-A Series MDS-B Series Specification Manual BNP-B3759 MELDAS AC Servo MDS-B-SVJ2 Series Specification and Instruction Manual BNP-B3937 MELDAS AC Servo/ Spindle MDS-C1 Series Specification Manual BNP-C3000
(Standard) (MDS-B-Vx) SV001 Motor side gear ratio SV002 Machine side gear ratio SV003 Position loop gain 1 SV004 Position loop gain 2 SV005 Speed loop gain 1 SV006 Speed loop gain 2 – SV007 Speed loop delay compensation – SV008 Speed loop lead compensation SV009 Current loop q axis lead compensation SV010 Current loop d axis lead compensation SV011 Current loop q axis gain SV012 Current loop d axis gain SV013 Current limit value SV014 Current limit value in special control SV015 Acceleration rate feed forward gain SV016 Lost motion compensation 1 SV017 Servo specification selection SV018 Ball screw pitch SV019 Position detector resolution SV020 Speed detector resolution SV021 Overload detection time constant SV022 Overload detection level
SV023 Excessive error detection width during servo ON
SV024 In-position detection width SV025 Motor/Detector type
SV026 Excessive error detection width during servo OFF
SV027 Servo function selection 1 SV028 Linear motor magnetic pole shift length – – – SV029 Speed at the change of speed loop gain – SV030 Voltage dead time compensation –/ / / SV031 Overshooting compensation 1 SV032 Torque offset

(Standard) (MDS-B-Vx) SV033 Servo function selection 2 SV034 Servo function selection 3 SV035 Servo function selection 4 SV036 Regenerative resistor type SV037 Load inertia scale SV038 Notch filter frequency 1 – SV039 Lost motion compensation timing – SV040 Non-sensitive band in feed forward control –/ / / SV041 Lost motion compensation 2 SV042 Overshooting compensation 2 SV043 Disturbance observer filter frequency SV044 Disturbance observer gain SV045 Frictional torque –/ / / SV046 Notch filter frequency 2 – – SV047 Inductive voltage compensation gain SV048 Vertical axis drop prevention time
SV049 Position loop gain 1 in spindle synchronous control
SV050 Position loop gain 2 in spindle synchronous control
SV051 Dual feedback control time constant – SV052 Dual feedback control non-sensitive band –
SV053 Excessive error detection width in special control
SV054 Overrun detection width in closed loop control –/–
SV055 Max. gate off delay time after emergency stop –
SV056 Deceleration time constant at emergency stop
SV057 SHG control gain
SV058 SHG control gain in spindle synchronous control
SV059 Collision detection torque estimating gain SV060 Collision detection level
SV061 D/A output channel 1 data No. SV062 D/A output channel 2 data No.
SV063 D/A output channel 1 output scale SV064 D/A output channel 2 output scale SV065 Tool end compensation spring constant – –

(1) Details for servo parameters
For parameters marked with a (PR) in the table, turn the NC power OFF after setting. After the power is turned ON again, the parameter is validated.
! In the explanation on bits, set all bits not used, including blank bits, to “0”.
No. Items Details Setting range
Motor side gear ratio
Set the motor side and machine side gear ratio. For the rotary axis, set the total deceleration (acceleration) ratio. Even if the gear ratio is within the setting range, the electronic gears may overflow and cause an alarm.
Machine side gear ratio
Position loop gain 1
Set the position loop gain. The standard setting is “33”. The higher the setting value is, the more precisely the command can be followed and the shorter the positioning time gets, however, note that a bigger shock is applied to the machine during acceleration/deceleration. When using the SHG control, also set SV004 (PGN2) and SV057 (SHGC).
1 to 200 (rad/s)
Position loop gain 2
When using the SHG control, also set SV003 (PGN1) and SV057 (SHGC). When not using the SHG control, set to “0”.
0 to 999 (rad/s)
Set the speed loop gain. Set this according to the load inertia size. The higher the setting value is, the more accurate the control will be, however, vibration tends to occur. If vibration occurs, adjust by lowering by 20 to 30%. The value should be determined to be 70 to 80% of the value at the time when the vibration stops.
2206 Not used. Set to “0”. 0
2207 Not used. Set to “0”. 0
Speed loop lead compensation
Set the gain of the speed loop integration control. The standard setting is “1364”. During the SHG control, the standard setting is “1900”. Adjust the value by increasing/decreasing it by about 100 at a time. Raise this value to improve contour tracking precision in high-speed cutting. Lower this value when the position droop vibrates (10 to 20Hz).
Current loop q axis lead compensation
Set the gain of current loop. As this setting is determined by the motor’s electrical characteristics, the setting is fixed for each type of motor. Set the standard values for all the parameters depending on each motor type.
Current loop d axis lead compensation
Current loop q axis gain
Current loop d axis gain
Speed loop gain

No. Items Details Setting range
Set the normal current (torque) limit value. (Limit values for both + and - direction.) When the value is “500” (a standard setting), the maximum torque is determined by the specification of the motor.
0 to 500 (Stall [rated] current %)
Current limit value in special control
Set the current (torque) limit value in a special control (initial absolute position setting, stopper control, etc). (Limit values for both of the + and - directions.) Set to “500” when not using.
0 to 500 (Stall [rated] current %)
Acceleration rate feed forward gain
When a relative error in the synchronous control is large, apply this parameter to the axis that is delaying. The standard setting value is “0”. For the SHG control, set to “100”. To adjust a relative error in acceleration/ deceleration, increase the value by 50 to 100 at a time.
Lost motion compensation 1
Set this when the protrusion (that occurs due to the non-sensitive band by friction, torsion, backlash, etc) at quadrant change is too large. This compensates the torque at quadrant change. This is valid only when the lost motion compensation (SV027 (SSF1/lmc)) is selected.
Type 1: When SV027 (SSF1)/ bit9, 8 (lmc)=01 Set the compensation amount based on the motor torque before the quadrant change. The standard setting is “100”. Setting to “0” means the compensation amount is zero. Normally, use Type 2.
Type 2: When SV027 (SSF1)/ bit9, 8 (lmc)=10 Set the compensation amount based on the stall (rated) current of the motor. The standard setting is double of the friction torque. Setting to “0” means the compensation amount is zero.
-1 to 100 (Stall [rated] current %)
When you wish different compensation amount depending on the direction When SV041 (LMC2) is “0”, compensate with the value of SV016 (LMC1) in both of the + and -directions. If you wish to change the compensation amount depending on the command direction, set this and SV041 (LMC2). (SV016: + direction, SV041: - direction. However, the directions may be opposite depending on other settings.) When “-1” is set, the compensation won’t be performed in the direction of the command.
Current limit value · 2214 SV014 ILMTsp


7 6 5 4 3 2 1 0 abs vdir mc dmk
bit Meaning when “0” is set Meaning when “1” is set
3 mc Contactor control output invalid Contactor control output valid
HA053N to HA33N motor Detector installation position standard (A, C)
HA053N to HA33N motor Detector installation position 90 degrees (B, D)
(Note) Set to “0” for bits with no particular description.
Set the ball screw pitch. Set to “360” for the rotary axis. 1 to 32767 (mm/rev)
For both parameters, set the number of pulses per one revolution of the motor detector.

No. Items Details Setting range
Overload detection time constant
Set the detection time constant of Overload 1 (Alarm 50). Set to “60” as a standard. (For machine tool builder adjustment.)
1 to 300 (s)
Set the current detection level of Overload 1 (Alarm 50) in respect to the stall (rated) current. Set to “150” as a standard. (For machine tool builder adjustment.)
Excessive error detection width during servo ON
Set the excessive error detection width when servo ON.
0 to 32767 (mm)
When “0” is set, the excessive error detection will not be performed.
Set the in-position detection width. Set the accuracy required for the machine. The lower the setting is, the higher the positioning accuracy gets, however, the cycle time (setting time) becomes longer. The standard setting is “50”.
0 to 32767 (µm)


F E D C B A 9 8 pen ent
7 6 5 4 3 2 1 0 mtyp
1 Set- ting 0x 1x 2x 3x 4x 5x 6x 7x 8x

No. Items Details Setting range (Continued from the previous page)
bit Explanation 8 9
Set the speed detector type. Set to “2”.
B
C D
Set the position detector type. Set to “2”.
F
2226 SV026 OD2
Excessive error detection width during servo OFF
Set the excessive error detection width when servo ON. For the standard setting, refer to the explanation of SV023 (OD1). When “0” is set, the excessive error detection will not be performed.
0 to 32767 (mm)
Servo function selection 1
F E D C B A 9 8 aflt zrn2 ovs lmc
7 6 5 4 3 2 1 0 vfct zup
bit Meaning when “0” is set Meaning when “1” is set
0 zup Vertical axis lift-up control stop Vertical axis lift-up control start 1
4 Set the jitter compensation No. of compensation pulses with a binary. 5 vfct
8 Set the compensation amount with SV016 (LMC1) and SV041 (LMC2). 9 lmc
A Set the compensation amount with SV031 (OVS1) and SV042 (OVS2).
E zrn2 Set to “1”.
F aflt Adoptive filter stops Adoptive filter starts
(Note) Set to “0” for bits with no particular description.
ent · pen · ovs

No. Items Details Setting range
2228 SV028 Not used. Set to “0”. 0
2229 SV029 Not used. Set to “0”. 0
Voltage dead time compensa- tion
When 100% is set, the voltage equivalent to the logical non-energized time will be compensated. Adjust in increments of 10% from the default value 100%. If increased too much, vibration or vibration noise may be generated. When not using, set to “0”.
Set this if overshooting occurs during positioning. This compensates the motor torque during positioning. This is valid only when the overshooting compensation SV027 (SSF1/ovs) is selected.
-1 to 100 (Stall [rated] current %)
Type 1: When SV027 (SSF1)/ bit11, 10 (ovs)=01 Set the compensation amount based on the motor’s stall (rated) current. Increase by 1% and determine the amount that overshooting doesn’t occur. In Type 1, compensation during the feed forward control during circular cutting won’t be performed.
Type 2: When SV027 (SSF1)/ bit11, 10 (ovs)=10 Use this if you perform the overshooting compensation during the feed forward control during circular cutting. The setting method is the same in Type 1.
When you wish different compensation amount depending on the direction When SV042 (OVS2) is “0”, compensate with the value of SV031 (OVS1) in both of the + and -directions. If you wish to change the compensation amount depending on the command direction, set this and SV042 (OVS2). (SV031: + direction, SV042: - direction. However, the directions may be opposite depending on other settings.) When “-1” is set, the compensation won’t be performed in the direction of the command.
Set the unbalance torque of vertical axis and inclined axis.
-100 to 100 (Stall [rated] current %)
Overshoot- ing compensa- tion 1 · Torque offset


F E D C B A 9 8 afs
7 6 5 4 3 2 1 0 fhz2 nfd
bit Meaning when “0” is set Meaning when “1” is set 0 Set the filter depth for Notch filter (SV038: FHz1). 1 The control is stabilized by making the filter shallower.
2 Value 0 2 4 6 8 A C E
DeepÅ Æ Shallow 4 Set the operation frequency of Notch filter 2. 5 fhz2 00: No operation 01:2250Hz 10:1125Hz 11:750Hz
Set the vibration sensitivity of the adaptive filter. If the filter depth is not deep enough (generally 70% or more) and the vibration cannot be sufficiently eliminated, raise the value.
(Note) Set to “0” for bits with no particular description.

No. Items Details Setting range
2234 SV034 SSF3
Servo function selection 3
7 6 5 4 3 2 1 0 daf2 daf1 dac2 dac1 mon
bit Meaning when “0” is set Meaning when “1” is set 0 NC servo monitor MAX current display data changeover
1 Set- ting MAX current 1 MAX current 2
2 0 Max. current command value when power is turned ON (%)
Max. current command value for one second (%)
1 Max. current command value for one second (%)
Max. current FB value for one second (%)
2 Max. current FB value when power is turned ON (%)
Max. current FB value for one second (%)
3 Load inertia rate (%) -
4 Adaptive filter operation frequency (Hz)
Adaptive filter operation gain (%)
5 PN bus voltage (V) Regenerative operation frequency monitor (The number of times/sec)
6 Estimated max. torque for one second (%)
Max. current FB value for one second (%)
7 Estimated max. torque for one second (%)
Max. disturbance torque for two seconds (%)
8 to F Setting prohibited
4 dac1 D/A output ch.1 overflow setting D/A output ch.1 clamp setting 5 dac2 D/A output ch.2 overflow setting D/A output ch.2 clamp setting
6 daf1 D/A output ch.1 no filter D/A output ch.1 filter setting
7 daf2 D/A output ch.2 no filter D/A output ch.2 filter setting
B
C D
E
F
(Note) Set to “0” for bits with no particular description.
mon


F E D C B A 9 8 cl2n clG1
bit Meaning when “0” is set Meaning when “1” is set 0 1
Collision detection method 1 Set the collision detection level during cutting feed (G1). The G1 collision detection level=SV060*clG1. When clG1=0, the collision detection method 1 during cutting feed won’t function.
(Note) Set to “0” for bits with no particular description.


F E D C B A 9 8 amp rtyp
7 6 5 4 3 2 1 0 emgx
4 Set the external emergency stop function. (Setting is prohibited for values with no description.)
A 0 Drive unit standard built-in resistor (SVJ2-01 doesn’t have a built-in resistor)

No. Items Details Setting range
2237 SV037 JL Load inertia scale
Set “the motor inertia + motor axis conversion load inertia” in respect to the motor inertia.
Notch filter frequency 1
Set the vibration frequency to suppress if machine vibration occurs. (Valid at 72 or more) When not using, set to “0”.
0 to 3000 (Hz)
Lost motion compensation timing
Set this when the lost motion compensation timing doest not match. Adjust by increasing the value by 10 at a time.
0 to 2000 (ms)
Non-sensitive band in feed forward control
Set the non-sensitive bad of the lost motion compensation and overshooting compensation during the feed forward control. When “0” is set, the actual value that will be set is 2µm. Adjust by increasing by 1µm.
Lost motion compensation 2
Set this with SV016 (LMC1) only when you wish to set the lost motion compensation amount to be different depending on the command directions. Set to “0” as a standard.
-1 to 200 (Stall [rated] current %)
Set this with SV031 (OVS1) only when you wish to set the overshooting compensation amount to be different depending on the command directions. Set to “0” as a standard.
-1 to 100 (Stall [rated] current %)
Disturbance observer filter frequency
Set the disturbance observer filter band. The standard setting is “300”. Lower the setting by 50 at a time if vibration occurs. To use the disturbance observer, also set SV037 (JL) and SV044 (OBS2). When not using, set to “0”.
0 to 1000 (rad/s)
Set the disturbance observer gain. The standard setting is “100” to “300”. To use the disturbance observer, also set SV037 (JL) and SV043 (OBS1). When not using, set to “0”.
Set the frictional torque when using the collision detection function.
0 to 100 (Stall [rated] current %)
2246 SV046 Not used. Set to “0”. 0
Inductive voltage compensation gain
Set the inductive voltage compensation gain. Set to “100” as a standard. If the current FB peak exceeds the current command peak, lower the gain.
Vertical axis drop prevention time
Input a length of time to prevent the vertical axis from dropping by delaying Ready OFF until the brake works when the emergency stop occurs. Increase the setting by 100ms at a time and set the value where the axis does not drop.

No. Items Details Setting range
Position loop gain 1 in spindle synchronous control
Set the position loop gain during the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis). Set the same value as the value of the spindle parameter, position loop gain in synchronous control. When performing the SHG control, set this with SV050 (PGN2sp) and SV058 (SHGCsp).
1 to 200 (rad/s)
2250 PGN2sp Position loop gain 2 in spindle synchronous control
Set this with SV049 (PGN1sp) and SV058 (SHGCsp) if you wish to perform the SHG control in the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis). When not performing the SHG control, set to “0”.
0 to 999 (rad/s)
2251 SV051 Not used. Set to “0”. 0
2252 SV052 Not used. Set to “0”. 0
Excessive error detection width in special control
Set the excessive error detection width when servo ON in a special control (initial absolute position setting, stopper control, etc.). If “0” is set, excessive error detection won’t be performed when servo ON during a special control.
0 to 32767 (mm)
2254 SV054 Not used. Set to “0”. 0
2255 SV055 Not used. Set to “0”. 0
Deceleration time constant at emergency stop
Set the time constant used for the deceleration control at emergency stop. Set a length of time that takes from rapid traverse rate (rapid) to stopping. Normally, set the same value as the rapid traverse acceleration/deceleration time constant.
0 to 5000 (ms)
When performing the SHG control, set this with S003 (PGN1) and SV004 (PGN2). When not performing the SHG control, set to “0”.
0 to 999 (rad/s)
SHG control gain in spindle synchronous control
Set this with SV049 (PGN1sp) and SV050 (PGN2sp) if you wish to perform the SHG control in the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis). When not performing the SHG control, set to “0”.
0 to 999 (rad/s)
Collision detection torque estimating gain
To use the collision detection function, set the torque estimating gain. In the case of MDS-B-SVJ2, the value is the same as the load inertia ratio that includes the motor inertia. (=SV037:JL) If acceleration/deceleration is performed after setting SV034.mon=3 and SV060=0, the load inertia ratio will be displayed on the NC monitor screen.
When using the collision detection function, set the collision detection level during the G0 feeding. If “0” is set, none of the collision detection function will work.
0 to 200 (Stall [rated] current %)

No. Items Details Setting range
D/A output channel 1 data No.
Input the data number you wish to output to D/A output channel.
D/A output channel 2 data No.
D/A output channel 1 output scale
When “0” is set, output is done with the standard output unit. Set other than “0” when you wish to change the unit. Set the scale with a 1/256 unit. When “256” is set, the output unit will be the same as the standard output unit.
D/A output channel 2 output scale
2265 SV065 Not used. Set to “0”. 0

(2) Initial setting value
52 HC 102* HC 102 HC 152* HC 152 HC 202* HC 202 HC 352* Drive unit
capacity 06 07 10 10 20 10 20 20
SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 50 80 50 80 50 115 80 130 SV006 0 SV007 0 SV008 VIA 1364 SV009 IQA 8192 4096 8192 4096 8192 2048 4096 2048 SV010 IDA 8192 4096 8192 4096 8192 2048 4096 2048 SV011 IQG 512 256 384 256 384 256 384 256 SV012 IDG 512 256 384 256 384 256 384 256 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 - SV024 INP 50 SV025 MTYP 22B0 22B1 22B1 22B2 22B2 22B3 22B3 22B4 SV026 OD2 - SV027 SSF1 4000 SV028 0 SV029 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0
(a) HC**/HC**R series · Motor HC

52 HC 102* HC 102 HC 152* HC 152 HC 202* HC 202 HC 352* Drive unit
capacity 06 07 10 10 20 10 20 20
SV033 SSF2 0 SV034 SSF3 0 SV035 SSF4 0 SV036 PTYP - SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 0 SV052 0 SV053 OD3 0 SV054 0 SV055 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0
Motor HC

53 HC 103 HC 153 HC 203* HC 103R HC 153R HC 203R Drive unit
capacity 06 10 20 20 10 10 20
SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 80 80 80 100 10 10 10 SV006 0 SV007 0 SV008 VIA 1364 SV009 IQA 4096 4096 4096 2048 8192 8192 8192 SV010 IDA 4096 4096 4096 2048 8192 8192 8192 SV011 IQG 256 256 256 200 384 384 256 SV012 IDG 256 256 256 200 384 384 256 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 - SV024 INP 50 SV025 MTYP 22C0 22C1 22C2 22C3 22E1 22E2 22E3 SV026 OD2 - SV027 SSF1 4000 SV028 0 SV029 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0
Motor HC

53 HC 103 HC 153 HC 203* HC 103R HC 153R HC 203R Drive unit
capacity 06 10 20 20 10 10 20
SV033 SSF2 0 SV034 SSF3 0 SV035 SSF4 0 SV036 PTYP - SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 0 SV052 0 SV053 OD3 0 SV054 0 SV055 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0
Motor HC

Motor HA 40N HA 80N HA 100N HA 200N* HA 053N HA 13N HA 23N HA 33N HA 43N HA 83N HA 103N* Drive unit
capacity 06 10 20 20 01 01 03 03 06 10 20
SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 90 150 150 220 35 120 150 180 SV006 0 SV007 0 SV008 VIA 1364 SV009 IQA 2048 SV010 IDA 2048 SV011 IQG 512 512 512 200 256 512 512 512 SV012 IDG 512 512 512 200 256 512 512 512 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 - SV024 INP 50 SV025 MTYP 2200 2201 2202 2203 228C 228D 228E 228F 2280 2281 2282 SV026 OD2 - SV027 SSF1 4000 SV028 0 SV029 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0
(b) HA**N series

Motor HA 40N HA 80N HA 100N HA 200N* HA 053N HA 13N HA 23N HA 33N HA 43N HA 83N HA 103N* Drive unit
capacity 06 10 20 20 01 01 03 03 06 10 20
SV033 SSF2 0 SV034 SSF3 0 SV035 SSF4 0 SV036 PTYP - SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 0 SV052 0 SV053 OD3 0 SV054 0 SV055 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0

102 HC-SF
152 HC-SF
202 HC-SF
352 HC-SF
53 HC-SF
103 HC-SF
153 HC-SF
203 HC-SF
capacity 06 07 10 10 20 06 07 10 10 20
SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 80 80 80 120 130 90 90 130 180 180 SV006 0 SV007 0 SV008 VIA 1364 SV009 IQA 8192 4096 4096 2048 2048 4096 4096 2048 2048 2048 SV010 IDA 8192 4096 4096 2048 2048 4096 4096 2048 2048 2048 SV011 IQG 500 300 300 300 250 250 250 200 200 200 SV012 IDG 500 300 300 300 250 250 250 200 200 200 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 16 SV020 RNG2 16 SV021 OLT 60 SV022 OLL 150 SV023 OD1 - SV024 INP 50 SV025 MTYP 22B0 22B1 22B2 22B3 22B4 22C0 22C1 22C2 22C3 22C4 SV026 OD2 - SV027 SSF1 4000 SV028 0 SV029 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0
(c) HC-SF series · Motor HC-SF · 353 Drive unit

102 HC-SF
152 HC-SF
202 HC-SF
352 HC-SF
53 HC-SF
103 HC-SF
153 HC-SF
203 HC-SF
capacity 06 07 10 10 20 06 07 10 10 20
SV033 SSF2 0 SV034 SSF3 0 SV035 SSF4 0 SV036 PTYP - SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 0 SV052 0 SV053 OD3 0 SV054 0 SV055 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0
Motor HC-SF · 353 Drive unit

153 HC-RF
203 HA-FF
053 HA-FF
13 HA-FF
23 HA-FF
33 HA-FF
43 HA-FF
capacity 10 10 20 01 01 03 03 04 06
SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 10 13 13 18 20 20 SV006 0 SV007 0 SV008 VIA 1364 SV009 IQA 8192 4096 SV010 IDA 8192 4096 SV011 IQG 384 384 256 500 300 700 500 700 700 SV012 IDG 384 384 256 500 300 700 500 700 700 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 16 16 16 8 SV020 RNG2 16 16 16 8 SV021 OLT 60 SV022 OLL 150 SV023 OD1 - SV024 INP 50 SV025 MTYP 22E1 22E2 22E3 227C 227D 227E 227F 2270 2271 SV026 OD2 - SV027 SSF1 4000 SV028 0 SV029 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0
(d) HC-RF/HA-FF series · Motor HC-RF · 63 Drive unit

153 HC-RF
203 HA-FF
053 HA-FF
13 HA-FF
23 HA-FF
33 HA-FF
43 HA-FF
capacity 10 10 20 01 01 03 03 04 06
SV033 SSF2 0 SV034 SSF3 0 SV035 SSF4 0 SV036 PTYP - SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 0 SV052 0 SV053 OD3 0 SV054 0 SV055 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0
Motor HC-RF · 63 Drive unit

13 HC-MF
23 HC-MF
43 HC-MF
capacity 01 01 03 04 07
SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 6 8 SV006 0 SV007 0 SV008 VIA 1364 SV009 IQA 4096 SV010 IDA 4096 SV011 IQG 200 300 400 300 300 SV012 IDG 200 300 400 300 300 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 8 SV020 RNG2 8 SV021 OLT 60 SV022 OLL 150 SV023 OD1 - SV024 INP 50 SV025 MTYP 229C 229D 229E 2290 2291 SV026 OD2 - SV027 SSF1 4000 SV028 0 SV029 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0
(e) HC-MF series · Motor HC-MF · 73 Drive unit

13 HC-MF
23 HC-MF
43 HC-MF
capacity 01 01 03 04 07
SV033 SSF2 0 SV034 SSF3 0 SV035 SSF4 0 SV036 PTYP - SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 0 SV052 0 SV053 OD3 0 SV054 0 SV055 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0
Motor HC-MF · 73 Drive unit

(1) Details for servo parameters
For parameters marked with a (PR) in the table, turn the NC power OFF after setting. After the power is turned ON again, the parameter is validated.
! In the explanation on bits, set all bits not used, including blank bits, to “0”.
No. Items Details Setting range
Motor side gear ratio
Set the motor side and machine side gear ratio. For the rotary axis, set the total deceleration (acceleration) ratio. Even if the gear ratio is within the setting range, the electronic gears may overflow and cause an alarm.
Machine side gear ratio
Position loop gain 1
Set the position loop gain. The standard setting is “33”. The higher the setting value is, the more precisely the command can be followed and the shorter the positioning time gets, however, note that a bigger shock is applied to the machine during acceleration/deceleration. When using the SHG control, also set SV004 (PGN2) and SV057 (SHGC). (If “201” or bigger is set, the SHG control cannot be used.)
1 to 200 (In case of MDS-B-Vx4, 1 to 400) (rad/s)
Position loop gain 2
When using the SHG control, also set SV003 (PGN1) and SV057 (SHGC). When not using the SHG control, set to “0”.
Speed loop gain 1
Set the speed loop gain. Set this according to the load inertia size. The higher the setting value is, the more accurate the control will be, however, vibration tends to occur. If vibration occurs, adjust by lowering by 20 to 30%. The value should be determined to be 70 to 80% of the value at the time when the vibration stops.
Speed loop gain 2
If the noise is bothersome at high speed during rapid traverse, etc, lower the speed loop gain. As in the right figure, set the speed loop gain of the speed 1.2 times as fast as the motor’s rated speed, and use this with SV029 (VCS). When not using, set to “0”.
VCS VLMT 0
(Rated speed*1.2)
(rad/s)

No. Items Details Setting range
Speed loop delay compensation
Set this when the limit cycle occurs in the full-closed loop, or overshooting occurs in positioning. Select the control method with SV027 (SSF1)/bit1, 0 (vcnt). Normally, use “Changeover type 2”. When you set this parameter, make sure to set the torque offset (SV032 (TOF)). When not using, set to “0”.
No changeover When SV027 (SSF1)/ bit1, 0 (vcnt)=00 The delay compensation control is always valid.
Changeover type 1 When SV027 (SSF1)/ bit1, 0 (vcnt)=01 The delay compensation control works when the command from the NC is “0”. Overshooting that occurs during pulse feeding can be suppressed.
Changeover type 2 When SV027 (SSF1)/ bit1, 0 (vcnt)=10 The delay compensation control works when the command from the NC is “0” and the position droop is “0”. Overshooting or the limit cycle that occurs during pulse feeding or positioning can be suppressed.
Speed loop lead compensation
Set the gain of the speed loop integration control. The standard setting is “1364”. During the SHG control, the standard setting is “1900”. Adjust the value by increasing/decreasing it by about 100 at a time. Raise this value to improve contour tracking precision in high-speed cutting. Lower this value when the position droop vibrates (10 to 20Hz).
Current loop q axis lead compensation
Set the gain of current loop. As this setting is determined by the motor’s electrical characteristics, the setting is fixed for each type of motor. Set the standard values for all the parameters depending on each motor type.
Current loop d axis lead compensation
Current loop q axis gain
1 to 4096 (In case of MDS-B-Vx4, 1 to 8192)
Current loop d axis gain
Set the normal current (torque) limit value. (Limit values for both + and - direction.) When the value is “500” (a standard setting), the maximum torque is determined by the specification of the motor.
0 to 999 (Stall [rated] current %)
Current limit value in special control
Set the current (torque) limit value in a special control (initial absolute position setting, stopper control, etc). (Limit values for both of the + and - directions.) Set to “500” when not using.
0 to 999 (Stall [rated] current %)
Current limit value · 2214 SV014 ILMTsp

No. Items Details Setting range
Acceleration rate feed forward gain
When a relative error in the synchronous control is large, apply this parameter to the axis that is delaying. The standard setting value is “0”. For the SHG control, set to “100”. To adjust a relative error in acceleration/deceleration, increase the value by 50 to 100 at a time.
Lost motion compensa- tion 1
Set this when the protrusion (that occurs due to the non-sensitive band by friction, torsion, backlash, etc) at quadrant change is too large. This compensates the torque at quadrant change. This is valid only when the lost motion compensation (SV027 (SSF1/lmc)) is selected.
Type 1: When SV027 (SSF1)/ bit9, 8 (lmc)=01 Set the compensation amount based on the motor torque before the quadrant change. The standard setting is “100”. Setting to “0” means the compensation amount is zero. Normally, use Type 2.
Type 2: When SV027 (SSF1)/ bit9, 8 (lmc)=10 Set the compensation amount based on the stall (rated) current of the motor. The standard setting is double of the friction torque. Setting to “0” means the compensation amount is zero.
-1 to 100 (Stall [rated] current %)
When you wish different compensation amount depending on the direction When SV041 (LMC2) is “0”, compensate with the value of SV016 (LMC1) in both of the + and -directions. If you wish to change the compensation amount depending on the command direction, set this and SV041 (LMC2). (SV016: + direction, SV041: - direction. However, the directions may be opposite depending on other settings.) When “-1” is set, the compensation won’t be performed in the direction of the command.

No. Items Details Setting range
F E D C B A 9 8 spm drvall drvup mpt3 mp 7 6 5 4 3 2 1 0 abs vdir fdir vfb seqh dfbx fdir2
bit Meaning when “0” is set Meaning when “1” is set
0 fdir2 Speed feedback forward polarity
Speed feedback reverse polarity 1 dfbx Dual feedback control stop Dual feedback control start
2 seqh READY/Servo ON time normal READY/Servo ON time high speed
3 vfb Speed feedback filter stop Speed feedback filter stop (2250Hz)
4 fdir Position feedback forward polarity
Position feedback reverse polarity 5 vdir Standard setting HA motor (4 pole motor)
Detector installation position 90 degrees (B, D)
7 abs Incremental control Absolute position control
8 mp MP scale 360P (2mm pitch) MP scale 720P (1mm pitch)
9 mpt3 MP scale ABS detection type 1, 2 MP scale ABS detection type 3
Standard setting Possible to connect a drive unit whose capacity is 1 rank higher/lower than the standard one.
Setting for normal use Possible to connect a drive unit with any capacity. C D
0 1 2 to F
: Setting for normal use : When using the S type drive unit (Only in the case of
(Note 1) Set to “0” for bits with no particular description.
(Note 2) bit3 (vfb) is only for MDS-C1-Vx.

No. Items Details Setting range
Set the ball screw pitch. Set to “360” for the rotary axis. 1 to 32767 (mm/rev)
In the case of the semi-closed loop control Set the same value as SV020 (RNG2). (Refer to the explanation of SV020.)
1 to 9999 (kp/rev)
In the case of the semi-closed loop control Set the same value as SV020 (RNG2). (Refer to the explanation of SV020.)
1 to 9999 (kp/pit)
Detector model name Resolution SV019 setting OHE25K-ET, OHA25K-ET 100,000(p/rev) 100 OSE104-ET, OSA104-ET 100,000(p/rev) 100
OSE105-ET, OSA105-ET 1,000,000(p/rev) 1000
RCN723 (Heidenhain) 8,000,000(p/rev) 8000
Relative position detection scale
Refer to specification manual for each detector
AT41 (Mitsutoyo) 1 (µm/p) The same as SV018 (PIT)
FME type, FLE type (Futaba)
Refer to specification manual for each detector
MP type (Mitsubishi Heavy Industries)
Refer to specification manual for each detector
AT342 (Mitsutoyo) 0.5 (µm/p) Twice as big as SV018 (PIT)
AT343 (Mitsutoyo) 0.05 (µm/p) 20 times as big as SV018 (PIT)
LC191M (Heidenhain) Refer to specification manual for each detector
LC491M (Heidenhain) Refer to specification manual for each detector
Set the number of pulses per one revolution of the motor end detector.
1 to 9999 (kp/rev)
Detector model name SV020 setting
OSE105, OSA105 1000

No. Items Details Setting range
Overload detection time constant
Set the detection time constant of Overload 1 (Alarm 50). Set to “60” as a standard. (For machine tool builder adjustment.)
1 to 999 (s)
Set the current detection level of Overload 1 (Alarm 50) in respect to the stall (rated) current. Set to “150” as a standard. (For machine tool builder adjustment.)
110 to 500 (Stall [rated] current %)
Excessive error detection width during servo ON
Set the excessive error detection width when servo ON.
0 to 32767 (mm)
When “0” is set, the excessive error detection will not be performed.
Set the in-position detection width. Set the accuracy required for the machine. The lower the setting is, the higher the positioning accuracy gets, however, the cycle time (setting time) becomes longer. The standard setting is “50”.
0 to 32767 (µm)


F E D C B A 9 8 pen ent 7 6 5 4 3 2 1 0 mtyp
bit Explanation 0 Set the motor type. 1 Set this along with SV017 (SPEC)/spm.
3 Set- ting 0x 1x 2x 3x 4x 5x 6x 7x
Set- ting 8x 9x Ax Bx Cx Dx Ex Fx

No. Items Details Setting range (Continued from the previous page)
bit Explanation 2) When SV017/spm=1 (S type drive unit) Set- ting 8x 9x Ax Bx Cx Dx Ex Fx
8 Set the detector type. 9
Set the position detector type for “pen”, and the speed detector type for “ent”. In the case of the semi-closed loop control, set the same value for “pen” and “ent”.
pen setting ent setting Detector model name
C 0 0 OSE104 D 1 1 OSA104
E 2 2 OSE105, OSA105
F
OHE25K-ET, OSE104-ET
OHA25K-ET, OSA104-ET
OSE105-ET, OSA105-ET, RCN723 (Heidenhain)
Relative position detection scale, MP type (Mitsubishi Heavy Industries)
AT41 (Mitsutoyo), FME type, FLE type (Futaba)
AT342,AT343 (Mitsutoyo), LC191M/491M (Heidenhain), MDS-B-HR
C C (Current synchroni-
The setting of the slave axis in the speed/current synchronization control. When the master axis is the semi-closed control.
D E (Current synchroni-
The setting of the slave axis in the speed/current synchronization control. When the master axis is the full-closed control. (Current synchronization control is only for MDS-C2-Vx.)

No. Items Details Setting range
Excessive error detection width during servo OFF
Set the excessive error detection width when servo ON. For the standard setting, refer to the explanation of SV023 (OD1). When “0” is set, the excessive error detection will not be performed.
0 to 32767 (mm)
Servo function selection 1
F E D C B A 9 8 aflt zrn2 afse ovs lmc 7 6 5 4 3 2 1 0 omr zrn3 vfct upc vcnt
bit Meaning when “0” is set Meaning when “1” is set
0 Set the execution changeover type of the speed loop delay compensation. 1 vcnt
2 upc Start torque compensation invalid
Start torque compensation valid
4 Set the number of compensation pulses of the jitter compensation. 5 vfct
6 zrn3 ABS scale: Set to “1” in using AT342, AT343, LC191M/491M.
7 omr Machine end compensation invalid
Machine end compensation valid
8 Set the compensation amount with SV016 (LMC1) and SV041 (LMC2). 9 lmc
A Set the compensation amount with SV031 (OVS1) and SV042 (OVS2).
E zrn2 Set to “1”.
F aflt Adoptive filter stop Adoptive filter start
(Note) Set to “0” for bits with no particular description.
2228 SV028 Not used. Set to “0”. 0
2229 SV029 Speed at the change of speed loop gain
If the noise is bothersome at high speed during rapid traverse, etc, lower the speed loop gain. Set the speed at which the speed loop gain changes, and use this with SV006 (VGN2). (Refer to SV006.) When not using, set to “0”.
0 to 9999 (r/min)
ovs

No. Items Details Setting range
The higher order 8bits and lower order 8bits are used for different functions. “The setting value of SV030” = (Icx*256) + IVC
SV030 IVC (Low order)
Voltage dead time compensa- tion
When 100% is set, the voltage equivalent to the logical non-energized time will be compensated. When “0” is set, a 100% compensation will be performed. Adjust in increments of 10% from the default value 100%. If increased too much, vibration or vibration noise may be generated.
SV030 Icx (High order)
Current bias 1 Set to “0” as a standard. Use this in combination with SV040 and the high order 8bits of SV045.
Set this if overshooting occurs during positioning. This compensates the motor torque during positioning. This is valid only when the overshooting compensation SV027 (SSF1/ovs) is selected.
-1 to 100 (Stall [rated] current %)
Type 1: When SV027 (SSF1)/ bitB, A (ovs)=01 Set the compensation amount based on the motor’s stall current. This compensates overshooting that occurs during pulse feeding. Normally, use Type 2.
Type 2: When SV027 (SSF1)/ bitB, A (ovs)=10 Set the compensation amount based on the motor’s stall current. Increase by 1% and determine the amount that overshooting doesn’t occur. In Type 2, compensation during the feed forward control during circular cutting won’t be performed.
Type 3: When SV027 (SSF1)/ bitB, A (ovs)=11 Use this to perform the overshooting compensation during circular cutting or the feed forward control. The setting method is the same in Type 2.
When you wish different compensation amount depending on the direction When SV042 (OVS2) is “0”, compensate with the value of SV031 (OVS1) in both of the + and -directions. If you wish to change the compensation amount depending on the command direction, set this and SV042 (OVS2). (SV031: + direction, SV042: - direction. However, the directions may be opposite depending on other settings.) When “-1” is set, the compensation won’t be performed in the direction of the command.
Torque offset Set the unbalance torque of vertical axis and inclined axis.
-100 to 100 (Stall [rated] current %)
Overshooting compensation 1


F E D C B A 9 8 dos hvx svx 7 6 5 4 3 2 1 0 nfd2 nf3 nfd1 zck
bit Meaning when “0” is set Meaning when “1” is set 0 zck Z phase check valid (Alarm 42) Z phase check invalid 1 Set the filter depth for Notch filter 1 (SV038).
2 Value 000 001 010 011 100 101 110 111
DeepÅ Æ Shallow 4 nf3 Notch filter 3 stop Notch filter 3 start (1125Hz) 5 Set the operation frequency of Notch filter 2 (SV046).
6 Value 000 001 010 011 100 101 110 111
8 svx Set the performance mode of the servo control. (Only for MDS-C1-Vx) 9 hvx
(Note) Set to “0” for bits with no particular description.


F E D C B A 9 8 ovsn 7 6 5 4 3 2 1 0 os2 zeg mohn has2 has1
bit Meaning when “0” is set Meaning when “1” is set
0 has1 Setting for normal use (Except for HC)
1 has2 Setting for normal use (Except for HC)
Z phase normal edge detection (Setting for normal use)
Z phase reverse edge detection (Valid only when SV027/bit6=1)
6 os2 Setting for normal use Overspeed detection level changeover
Set the non-sensitive band of the overshooting compensation type 3 in increments of 2µm at a time. In the feed forward control, the non-sensitive band of the model position droop is set, and overshooting of the model is ignored. Set the same value as the standard SV040.
(Note) Set to “0” for bits with no particular description.

No. Items Details Setting range
F E D C B A 9 8 clt clG1 cl2n clet cltq 7 6 5 4 3 2 1 0 ckab iup tdt
Servo function selection 4
bit Meaning when “0” is set Meaning when “1” is set 0 1
Td creation time setting Set to “0”. (For machine tool builder adjustment)
6 iup Set to “1” when using any of motors from HC152 to HC702 and from HC153 to HC453.
7 ckab Setting for normal use No signal 2 (Alarm 21) special detection
8 Set the retracting torque for collision detection in respect to the maximum torque of the motor. 9 cltq
A clet Setting for normal use
The disturbance torque peak of the latest two seconds is displayed in MPOS of the servo monitor screen.
B cl2n Collision detection method 2
Collision detection method 2 invalid
Collision detection method 1
Set the collision detection level during cutting feed (G1). The G1 collision detection level=SV060*clG1. When clG1=0, the collision detection method 1 during cutting feed won’t function.
F clt Setting for normal use
The guide value of the SV059 setting value is displayed in MPOS of the servo monitor screen.
(Note) bit7 (ckab) is only for MDS-C1-Vx.
tdt · valid · clG1


F E D C B A 9 8 amp rtyp 7 6 5 4 3 2 1 0 ptyp
When the CN4 connector of the drive unit and the power supply are connected, setting below is necessary. To validate the external emergency stop function, add 40h.
3 Set- ting 0x 1x 2x 3x 4x 5x 6x 7x 8x
8 Set the regenerative resistor type when MDS-A-CR is used.
A 0 MDS-C1-CV (Setting when using power supply regeneration)
Set “the motor inertia + motor axis conversion load inertia” in respect to the motor inertia.
Set the vibration frequency to suppress if machine vibration occurs. (Valid at 36 or more) When not using, set to “0”.

No. Items Details Setting range
Lost motion compensation timing
Set this when the lost motion compensation timing doest not match. Adjust by increasing the value by 10 at a time.
0 to 2000 (ms)
The higher order 8bits and lower order 8bits are used for different functions. “Setting value of SV040” = (Icy*256) + LMCT
SV040 LMCT (Low order)
Lost motion compensation non-sensitive band
Set the non-sensitive band of the lost motion compensation in the feed forward control. When “0” is set, the actual value that is set is 2µm. Adjust by increasing by 1µm at a time.
0 to 100 (µm)
SV040 Icy (High order)
Current bias 2 Normally, set to “40” if you use HC202 to HC902, HC203 to HC703. Use this in combination with SV030 and the high order 8bits of SV045.
Lost motion compensation 2
Set this with SV016 (LMC1) only when you wish to set the lost motion compensation amount to be different depending on the command directions. Set to “0” as a standard.
-1 to 200 (Stall [rated] current %)
Set this with SV031 (OVS1) only when you wish to set the overshooting compensation amount to be different depending on the command directions. Set to “0” as a standard.
-1 to 100 (Stall [rated] current %)
Disturbance observer filter frequency
Set the disturbance observer filter band. Set to “100” as a standard. To use the disturbance observer, also set SV037 (JL) and SV044 (OBS2). When not using, set to “0”.
0 to 1000 (rad/s)
Set the disturbance observer gain. The standard setting is “100” to “300”. To use the disturbance observer, also set SV037 (JL) and SV043 (OBS1). When not using, set to “0”.
The higher order 8bits and lower order 8bits are used for different functions. “Setting value of SV045” = (Icy*256) + LMCT
SV045 TRUB (Low order)
When you use the collision detection function, set the frictional torque.
0 to 100 (Stall [rated] current %)
SV045 Ib1 (High order)
Current bias 3 Set to “0” as a standard. Use this in combination with SV030 and the high order 8bits of SV040.
Notch filter frequency 2
Set the vibration frequency to suppress if machine vibration occurs. (Valid at 36 or more) When not using, set to “0”.
0 to 9000 (Hz)
Inductive voltage compensation gain
Set the inductive voltage compensation gain. Set to “100” as a standard. If the current FB peak exceeds the current command peak, lower the gain.
Vertical axis drop prevention time
Input a length of time to prevent the vertical axis from dropping by delaying Ready OFF until the brake works when the emergency stop occurs. Increase the setting by 100ms at a time and set the value where the axis does not drop.
0 to 20000 (ms)

No. Items Details Setting range
Position loop gain 1 in spindle synchronous control
Set the position loop gain during the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis).
1 to 200 (rad/s)
Set the same value as the value of the spindle parameter, position loop gain in synchronous control. When performing the SHG control, set this with SV050 (PGN2sp) and SV058 (SHGCsp).
2250 PGN2sp Position loop gain 2 in spindle synchronous control
Set this with SV049 (PGN1sp) and SV058 (SHGCsp) if you wish to perform the SHG control in the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis). When not performing the SHG control, set to “0”.
0 to 999 (rad/s)
Dual feed back control time constant
Set the control time constant in dual feed back. When “0” is set, the actual value that is set is 1ms. The higher the time constant is, the closer it gets to the semi-closed control, so the limit of the position loop gain is raised.
Dual feedback control non-sensitive band
Set the non-sensitive band in the dual feedback control. Set to “0” as a standard.
Excessive error detection width in special control
Set the excessive error detection width when servo ON in a special control (initial absolute position setting, stopper control, etc.). If “0” is set, excessive error detection won’t be performed when servo ON during a special control.
0 to 32767 (mm)
2249 SV049 PGN1sp · (ms) · (µm)

No. Items Details Setting range
When SV035 (SSF4)/ bitF (ckab)=0
-1 to 32767 (mm)
Overrun detection width in closed loop control
Set the overrun detection width in the full-closed loop control. If the gap between the motor end detector and the linear scale (machine end detector) exceeds the value set by this parameter, it is judged to be overrun and Alarm 43 will be detected. When “-1” is set, the alarm detection won’t be performed. When “0” is set, overrun is detected with a 2mm width.
When SV035 (SSF4)/ bitF (ckab)=1
(Note) This applies to only MDS-C1-Vx.
The higher order 8bits and lower order 8bits are used for different functions. “Setting value of SV054” =(NSE*256)+ORE
SV054 ORE (Low order)
Overrun detection- width in closed loop control
Set the overrun detection width in the full-closed loop control. If the gap between the motor end detector and the linear scale (machine end detector) exceeds the value set by this parameter, it is judged to be overrun and Alarm 43 will be detected. When “255” is set, the alarm detection won’t be performed. When “0” is set, overrun is detected with a 2mm width.
0 to 255 (mm)
SV054 NSE (High order)
Special detection width for No signal 2
When SV035 (SSF4)/ bitF (ckab) =1, this setting is valid. Set the special detection width for No signal 2 (Alarm 21). When “0” is set, overrun is detected with a 15µm width.
0 to 127 (µm)
Max. gate off delay time after emergency stop
Set a length of time from the point when the emergency stop is input to the point when READY OFF is compulsorily executed. Normally, set the same value as the absolute value of SV056. In preventing the vertical axis from dropping, the gate off is delayed for the length of time set by SV048 if SV055’s value is smaller than that of SV048.
0 to 20000 (ms)
Deceleration time constant at emergency stop
In the vertical axis drop prevention time control, set the time constant used for the deceleration control at emergency stop. Set a length of time that takes from rapid traverse rate (rapid) to stopping. Normally, set the same value as the rapid traverse acceleration/deceleration time constant. When executing the synchronous operation, put the minus sign to the settings of both of the master axis and slave axis.
-20000 to 20000 (ms)
When performing the SHG control, set this with S003 (PGN1) and SV004 (PGN2). When not performing the SHG control, set to “0”.
0 to 1200 (rad/s)
2255 SV055 EMGx · 2256 SV056 EMGt · SHG control gain

No. Items Details Setting range
SHG control gain in spindle synchronous control
Set this with SV049 (PGN1sp) and SV050 (PGN2sp) if you wish to perform the SHG control in the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis). When not performing the SHG control, set to “0”.
0 to 1200 (rad/s)
Collision detection torque estimating gain
Set the torque estimating gain when using the collision detection function. After setting as SV035/bitF(clt)=1 and performing acceleration/deceleration, set the value displayed in MPOS of the NC servo monitor screen. Set to “0” when not using the collision detection function.
When using the collision detection function, set the collision detection level during the G0 feeding. If “0” is set, none of the collision detection function will work.
(Stall [rated] current %)
D/A output channel 1 data No.
Input the data number you wish to output to D/A output channel. In the case of MDS-C1-V2, set the axis on the side to which the data will not be output to “-1”.
D/A output channel 2 data No.
D/A output channel 1 output scale
Set the scale with a 1/256 unit. When “0” is set, output is done with the standard output unit.
D/A output channel 2 output scale
Tool end compensation spring constant
Set the spring constant of the tool end compensation. In the semi-closed loop control, the tool end compensation amount is calculated with the following equation.
F (mm/min)2*SV065
F: Commanded speed R: Radius
When not using, set to “0”.

(2) Initial setting value
52 HC 102 HC 152 HC 202 HC 352 HC 452 HC 702 HC 902 Drive unit
capacity 05 10 20 20 35 45s 45 70s 70 90
SV001 PC1 - SV002 PC2 - SV003 PGN1 47 SV004 PGN2 0 SV005 VGN1 200 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 4096 SV010 IDA 4096 SV011 IQG 768 SV012 IDG 768 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 1000 0000 1000 0000 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xxB0 xxB1 xxB2 xxB3 xxB4 xx95 xxB5 xx96 xxB6 xxB7 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0
(a) HC**/HC**R series · Motor HC

52 HC 102 HC 152 HC 202 HC 352 HC 452 HC 702 HC 902 Drive unit
capacity 05 10 20 20 35 45s 45 70s 70 90
SV033 SSF2 0000 SV034 SSF3 0003 SV035 SSF4 0000 0000 0040 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 0 0 10240 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 FHz2 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 TLC 0
Motor HC

53 HC 103 HC 153 HC 203 HC 353 HC 453 HC 703 Drive unit
capacity 05 10 20 35 45s 45 70s 70 90
SV001 PC1 - SV002 PC2 - SV003 PGN1 47 SV004 PGN2 0 SV005 VGN1 200 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 4096 SV010 IDA 4096 SV011 IQG 768 SV012 IDG 768 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 1000 0000 1000 0000 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xxC0 xxC1 xxC2 xxC3 xxA4 xxC4 xxA5 xxC5 xxC6 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0
Motor HC

53 HC 103 HC 153 HC 203 HC 353 HC 453 HC 703 Drive unit
capacity 05 10 20 35 45s 45 70s 70 90
SV033 SSF2 0000 SV034 SSF3 0003 SV035 SSF4 0000 0000 0040 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 0 0 10240 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 FHz2 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 TLC 0
Motor HC

Motor HC 103R HC 153R HC 203R HC 353R Drive unit
capacity 10 10 20 35
SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 15 15 20 40 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 4096 SV010 IDA 4096 SV011 IQG 256 SV012 IDG 512 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xxE1 xxE2 xxE3 xxE4 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0

Motor HC 103R HC 153R HC 203R HC 353R Drive unit
capacity 10 10 20 35
SV033 SSF2 0200 SV034 SSF3 0000 SV035 SSF4 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 FHz2 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 TLC 0

Motor HA 40N HA 80N HA 100N HA 200N HA 300N HA 700N HA 900N Drive unit
capacity 05 10 20 35 45 70 90
SV001 PC1 - SV002 PC2 - SV003 PGN1 33 25 25 SV004 PGN2 0 SV005 VGN1 150 250 250 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 4096 SV010 IDA 4096 SV011 IQG 768 SV012 IDG 768 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xx00 xx01 xx02 xx03 xx04 xx05 xx06 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0
(b) HA**N series

Motor HA 40N HA 80N HA 100N HA 200N HA 300N HA 700N HA 900N Drive unit
capacity 05 10 20 35 45 70 90
SV033 SSF2 0000 SV034 SSF3 0000 SV035 SSF4 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 FHz2 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 TLC 0

Motor HA 43N HA 83N HA 93N HA 103N HA 203N HA 303N HA 703N HA 053N HA 13N HA 23N HA 33N Drive unit
capacity 05 10 20 35 45 70 90 01 01 03 03
SV001 PC1 - SV002 PC2 - SV003 PGN1 33 25 33 SV004 PGN2 0 SV005 VGN1 150 250 70 70 100 100 SV006 0 SV007 0 SV008 VIA 1364 SV009 IQA 4096 SV010 IDA 4096 SV011 IQG 768 SV012 IDG 768 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xx80 xx81 xx8A xx82 xx83 xx84 xx85 xx8C xx8D xx8E xx8F SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0

Motor HA 43N HA 83N HA 93N HA 103N HA 203N HA 303N HA 703N HA 053N HA 13N HA 23N HA 33N Drive unit
capacity 05 10 20 35 45 70 90 01 01 03 03
SV033 SSF2 0000 SV034 SSF3 0000 SV035 SSF4 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 FHz2 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 TLC 0

(1) Details for servo parameters
For parameters marked with a (PR) in the table, turn the NC power OFF after setting. After the power is turned ON again, the parameter is validated.
! In the explanation on bits, set all bits not used, including blank bits, to “0”.
No. Items Details Setting range
Motor side gear ratio
Set the motor side and machine side gear ratio. For the rotary axis, set the total deceleration (acceleration) ratio. Even if the gear ratio is within the setting range, the electronic gears may overflow and cause an alarm.
Machine side gear ratio
Position loop gain 1
Set the position loop gain. The standard setting is “33”. The higher the setting value is, the more precisely the command can be followed and the shorter the positioning time gets, however, note that a bigger shock is applied to the machine during acceleration/deceleration. When using the SHG control, also set SV004 (PGN2) and SV057 (SHGC).
1 to 200 (rad/s)
Position loop gain 2
When using the SHG control, also set SV003 (PGN1) and SV057 (SHGC). When not using the SHG control, set to “0”.
0 to 999 (rad/s)
Speed loop gain 1 Set the speed loop gain. Set this according to the load inertia size. The higher the setting value is, the more accurate the control will be, however, vibration tends to occur. If vibration occurs, adjust by lowering by 20 to 30%. The value should be determined to be 70 to 80% of the value at the time when the vibration stops.
Speed loop gain 2 If the noise is bothersome at high speed during rapid traverse, etc, lower the speed loop gain. As in the right figure, set the speed loop gain of the speed 1.2 times as fast as the motor’s rated speed, and use this with SV029 (VCS). When not using, set to “0”.
VGN1 VGN2
VCS VLMT 0
(Rated speed*1.2)

No. Items Details Setting range
Speed loop delay compensation
Set this when the limit cycle occurs in the full-closed loop, or overshooting occurs in positioning. Select the control method with SV027 (SSF1)/bit1, 0 (vcnt). Normally, use “Changeover type 2”. When you set this parameter, make sure to set the torque offset (SV032 (TOF)). When not using, set to “0”.
No changeover When SV027 (SSF1)/ bit1, 0 (vcnt)=00 The delay compensation control is always valid.
Changeover type 1 When SV027 (SSF1)/ bit1, 0 (vcnt)=01 The delay compensation control works when the command from the NC is “0”. Overshooting that occurs during pulse feeding can be suppressed.
Changeover type 2 When SV027 (SSF1)/ bit1, 0 (vcnt)=10 The delay compensation control works when the command from the NC is “0” and the position droop is “0”. Overshooting or the limit cycle that occurs during pulse feeding or positioning can be suppressed.
Speed loop lead compensation
Set the gain of the speed loop integration control. The standard setting is “1364”. During the SHG control, the standard setting is “1900”. Adjust the value by increasing/decreasing it by about 100 at a time. Raise this value to improve contour tracking precision in high-speed cutting. Lower this value when the position droop vibrates (10 to 20Hz).
Current loop q axis lead compensation
Set the gain of current loop. As this setting is determined by the motor’s electrical characteristics, the setting is fixed for each type of motor. Set the standard values for all the parameters depending on each motor type.
Current loop d axis lead compensation
Current loop q axis gain
Current loop d axis gain

No. Items Details Setting range
Set the normal current (torque) limit value. (Limit values for both + and - direction.) When the value is “500” (a standard setting), the maximum torque is determined by the specification of the motor.
0 to 999 (Stall [rated] current %)
Current limit value in special control
Set the current (torque) limit value in a special control (initial absolute position setting, stopper control, etc). (Limit values for both of the + and - directions.) Set to “500” when not using.
0 to 999 (Stall [rated] current %)
Acceleration rate feed forward gain
When a relative error in the synchronous control is large, apply this parameter to the axis that is delaying. The standard setting value is “0”. For the SHG control, set to “100”. To adjust a relative error in acceleration/deceleration, increase the value by 50 to 100 at a time.
Lost motion compensation 1
Set this when the protrusion (that occurs due to the non-sensitive band by friction, torsion, backlash, etc) at quadrant change is too large. This compensates the torque at quadrant change. This is valid only when the lost motion compensation (SV027 (SSF1/lmc)) is selected.
Type 1: When SV027 (SSF1)/ bit9, 8 (lmc)=01 Set the compensation amount based on the motor torque before the quadrant change. The standard setting is “100”. Setting to “0” means the compensation amount is zero. Normally, use Type 2.
Type 2: When SV027 (SSF1)/ bit9, 8 (lmc)=10 Set the compensation amount based on the stall (rated) current of the motor. The standard setting is double of the friction torque. Setting to “0” means the compensation amount is zero.
-1 to 100 (Stall [rated] current %)
When you wish different compensation amount depending on the direction When SV041 (LMC2) is “0”, compensate with the value of SV016 (LMC1) in both of the + and -directions. If you wish to change the compensation amount depending on the command direction, set this and SV041 (LMC2). (SV016: + direction, SV041: - direction. However, the directions may be opposite depending on other settings.) When “-1” is set, the compensation won’t be performed in the direction of the command.
Current limit value · 2214 SV014 ILMTsp


F E D C B A 9 8 mpt3 mp
7 6 5 4 3 2 1 0 abs vdir fdir spwv seqh dfbx fdir2
bit Meaning when “0” is set Meaning when “1” is set
Speed feedback reverse polarity 1 dfbx Dual feedback control stop Dual feedback control start
2 seqh READY/Servo ON time normal READY/Servo ON time high speed
3 spwv Normal mode High gain servo synchronous mode
HA motor (4 pole motor) Detector installation position 90 degrees (B, D)
8 mp MP scale 360P (2mm pitch) MP scale 720P (1mm pitch)
9 mpt3 MP scale ABS detection type 1, 2 MP scale ABS detection type 3
(Note) Set to “0” for bits with no particular description.
Set the ball screw pitch. Set to “360” for the rotary axis. 1 to 32767

No. Items Details Setting range
In the case of the semi-closed loop control Set the same value as SV020 (RNG2). (Refer to the explanation of SV020.)
1 to 9999 (kp/rev)
In the case of the full-closed loop control Set the number of pulses per ball screw pitch.
1 to 9999 (kp/pit)
Detector model name Resolution SV019 setting OHE25K-ET, OHA25K-ET 100,000(p/rev) 100
OSE104-ET, OSA104-ET 100,000(p/rev) 100
OSE105-ET, OSA105-ET 1,000,000(p/rev) 1000
Refer to specification manual for each detector
Relative position detection scale
AT41 (Mitsutoyo) 1 (µm/p) The same as SV018 (PIT)
Refer to specification manual for each detector
FME type, FLE type (Futaba)
Refer to specification manual for each detector
MP type (Mitsubishi Heavy Industries)
AT342 (Mitsutoyo) 0.5 (µm/p) Twice as big as SV018 (PIT)
Set the number of pulses per one revolution of the motor end detector.
1 to 9999 (kp/rev)
Detector model name SV020 setting
Equipped to HA053, HA13 (Only for
OHE25K, OHA25K (Only for
OSE105, OSA105 1000
2221 SV021 OLT
Overload detection time constant
Set the detection time constant of Overload 1 (Alarm 50). Set to “60” as a standard. (For machine tool builder adjustment.)
1 to 999 (s)
Set the current detection level of Overload 1 (Alarm 50) in respect to the stall (rated) current. Set to “150” as a standard. (For machine tool builder adjustment.)
110 to 500 (Stall [rated] current %)
Excessive error detection width during servo ON
Set the excessive error detection width when servo ON.
0 to 32767 (mm)
When “0” is set, the excessive error detection will not be performed.


Set the in-position detection width. Set the accuracy required for the machine. The lower the setting is, the higher the positioning accuracy gets, however, the cycle time (setting time) becomes longer. The standard setting is “50”.
F E D C B A 9 8 pen ent
7 6 5 4 3 2 1 0 mtyp
1 Set- ting 0x 1x 2x 3x 4x 5x 6x 7x
Set- ting 8x 9x Ax Bx Cx Dx Ex Fx


No. Items Details Setting range (Continued from the previous page)
Set the detector type. Set position detector type for “pen”, and speed detector type for “ent”. In the case of the semi-closed loop control, set the same value for “pen” and “ent”.
3 3 Equipped to HA053, HA13 (Only for MDS-B-Vx)
Relative position detection scale, MP type (Mitsubishi Heavy Industries)
The setting of the slave axis in the speed/current synchronization control. When the master axis is the semi-closed control.
Set the excessive error detection width when servo ON. For the standard setting, refer to the explanation of SV023 (OD1). When “0” is set, the excessive error detection will not be performed.

No. Items Details Setting range
F E D C B A 9 8 aflt zrn2 afse ovs lmc
Servo function selection 1
7 6 5 4 3 2 1 0 zrn3 vfct upc vcnt
bit Meaning when “0” is set Meaning when “1” is set
0 vcnt Set the execution changeover type of the speed loop delay compensation. 1
2 upc Start torque compensation invalid
Start torque compensation valid
4 Set the number of compensation pulses of the jitter compensation. 5 vfct
6 zrn3 ABS scale: Set to “1” in using AT342, AT343, LC191M/491M.
8 Set the compensation amount with SV016 (LMC1) and SV041 (LMC2). 9 lmc
A Set the compensation amount with SV031 (OVS1) and SV042 (OVS2).
E zrn2 Set to “1”.
F aflt Adoptive filter stops Adoptive filter starts
(Note) Set to “0” for bits with no particular description.
2228 SV028 Not used. Set to “0”. 0
Speed at the change of speed loop gain
If the noise is bothersome at high speed during rapid traverse, etc, lower the speed loop gain. Set the speed at which the speed loop gain changes, and use this with SV006 (VGN2). (Refer to SV006.) When not using, set to “0”.
0 to 9999 (r/min)
ovs

No. Items Details Setting range
The higher order 8bits and lower order 8bits are used for different functions. “The setting value of SV030” = (Icx*256) + IVC
SV030 IVC (Low order)
Voltage dead time compensation
When 100% is set, the voltage equivalent to the logical non-energized time will be compensated. When “0” is set, a 100% compensation will be performed. Adjust in increments of 10% from the default value 100%. If increased too much, vibration or vibration noise may be generated.
SV030 Icx (High order)
Current bias 1 Set to “0” as a standard. Use this in combination with SV040 and the high order 8bits of SV045.
Set this if overshooting occurs during positioning. This compensates the motor torque during positioning. This is valid only when the overshooting compensation SV027 (SSF1/ovs) is selected.
-1 to 100 (Stall [rated] current%)
Type 1: When SV027 (SSF1)/ bitB, A (ovs)=01 Set the compensation amount based on the motor’s stall current. This compensates overshooting that occurs during pulse feeding. Normally, use Type 2.
Type 2: When SV027 (SSF1)/ bitB, A (ovs)=10 Set the compensation amount based on the motor’s stall current. Increase by 1% and determine the amount that overshooting doesn’t occur. In Type 2, compensation during the feed forward control during circular cutting won’t be performed.
Type 3: When SV027 (SSF1)/ bitB, A (ovs)=11 Use this to perform the overshooting compensation during circular cutting or the feed forward control. The setting method is the same in Type 2.
When you wish different compensation amount depending on the direction When SV042 (OVS2) is “0”, compensate with the value of SV031 (OVS1) in both of the + and -directions. If you wish to change the compensation amount depending on the command direction, set this and SV042 (OVS2). (SV031: + direction, SV042: - direction. However, the directions may be opposite depending on other settings.) When “-1” is set, the compensation won’t be performed in the direction of the command.
Overshooting compensation 1


Set the unbalance torque of vertical axis and inclined axis.
bit Meaning when “0” is set Meaning when “1” is set
0 zck Z phase check valid (Alarm 42) Z phase check invalid
1 nfd1 Set the filter depth for Notch filter 1 (SV038).
2 Value 000 001 010 011 100 101 110 111
4 Set the operation frequency of Notch filter 2.
Set the performance mode of the servo control. (Only for MDS-C1-Vx)
(Note) Set to “0” for bits with no particular description.


F E D C B A 9 8 ovsn
7 6 5 4 3 2 1 0 os2 zeg has2 has1
bit Meaning when “0” is set Meaning when “1” is set 0 has1 Setting for normal use HAS control 1 valid
1 has2 Setting for normal use HAS control 2 valid
5 zeg Z phase normal edge detection Z phase reverse edge detection
6 os2 Setting for normal use Overspeed detection level changeover
Set the non-sensitive band of the overshooting compensation type 3 in increments of 2µm at a time. In the feed forward control, the non-sensitive band of the model position droop is set, and overshooting of the model is ignored. Set the same value as the standard SV040.
(Note) Set to “0” for bits with no particular description.

No. Items Details Setting range
F E D C B A 9 8 clt clG1 cl2n clet cltq
7 6 5 4 3 2 1 0 iup tdt
bit Meaning when “0” is set Meaning when “1” is set 0 Td creation time setting 1 Set to “0”. (For machine tool builder adjustment)
6 iup Set to “1” in the case of any motors from HC152 to HC702 and from HC153 to HC453.
8 Set the retracting torque for collision detection in respect to the maximum torque of the motor. 9 cltq
Setting for normal use
The disturbance torque peak of the latest two seconds is displayed in MPOS of the servo monitor screen.
B cl2n Collision detection method 2
valid Collision detection method 2 invalid
Collision detection method 1 Set the collision detection level during cutting feed (G1). The G1 collision detection level=SV060*clG1. When clG1=0, the collision detection method 1 during cutting feed won’t function.
Setting for normal use The guide value of the SV059 setting value is displayed in MPOS of the servo monitor screen.
(Note) Set to “0” for bits with no particular description.


F E D C B A 9 8 amp rtyp
7 6 5 4 3 2 1 0 ptyp
When the CN4 connector of the drive unit and the power supply are connected, setting below is necessary. To validate the external emergency stop function, add 40h.
3 Set- ting 0x 1x 2x 3x 4x 5x 6x7x 8x
8 Set the regenerative resistor type when MDS-A-CR is used.
A 0 MDS-C1-CV (Setting when using power supply regeneration)

No. Items Details Setting range
2237 SV037 JL Load inertia scale
Set “the motor inertia + motor axis conversion load inertia” in respect to the motor inertia.
Notch filter frequency 1
Set the vibration frequency to suppress if machine vibration occurs. (Valid at 72 or more) When not using, set to “0”.
Lost motion compensation timing
Set this when the lost motion compensation timing doest not match. Adjust by increasing the value by 10 at a time.
The higher order 8bits and lower order 8bits are used for different functions. “Setting value of SV040” = (Icy*256) + LMCT
Lost motion compensation non-sensitive band
Set the non-sensitive band of the lost motion compensation in the feed forward control. When “0” is set, the actual value that is set is 2µm. Adjust by increasing by 1µm at a time.
0 to 100 (µm)
Current bias 2 Normally, set to “40” if you use HC202 to HC902, HC203 to HC703. Use this in combination with SV030 and the high order 8bits of SV045.
Lost motion compensation 2
Set this with SV016 (LMC1) only when you wish to set the lost motion compensation amount to be different depending on the command directions. Set to “0” as a standard.
-1 to 200 (Stall [rated] current %)
Set this with SV031 (OVS1) only when you wish to set the overshooting compensation amount to be different depending on the command directions. Set to “0” as a standard.
-1 to 100 (Stall [rated] current %)
Disturbance observer filter frequency
Set the disturbance observer filter band. Set to “100” as a standard. To use the disturbance observer, also set SV037 (JL) and SV044 (OBS2). When not using, set to “0”.
0 to 1000 (rad/s)
Set the disturbance observer gain. The standard setting is “100” to “300”. To use the disturbance observer, also set SV037 (JL) and SV043 (OBS1). When not using, set to “0”.
The higher order 8bits and lower order 8bits are used for different functions. “Setting value of SV045” = (Icy*256) + LMCT
SV045 TRUB (Low order)
When you use the collision detection function, set the frictional torque.
0 to 100 (Stall [rated] current %)
SV045 Ib1 (High order)
Current bias 3 Set to “0” as a standard. Use this in combination with SV030 and the high order 8bits of SV040.

No. Items Details Setting range
2246 SV046 Not used. Set to “0”. 0
Inductive voltage compensation gain
Set the inductive voltage compensation gain. Set to “100” as a standard. If the current FB peak exceeds the current command peak, lower the gain.
Vertical axis drop prevention time
Input a length of time to prevent the vertical axis from dropping by delaying Ready OFF until the brake works when the emergency stop occurs. Increase the setting by 100ms at a time and set the value where the axis does not drop.
0 to 20000 (ms)
Position loop gain 1 in spindle synchronous control
Set the position loop gain during the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis). Set the same value as the value of the spindle parameter, position loop gain in synchronous control. When performing the SHG control, set this with SV050 (PGN2sp) and SV058 (SHGCsp).
1 to 200 (rad/s)
2250 PGN2sp Position loop gain 2 in spindle synchronous control
Set this with SV049 (PGN1sp) and SV058 (SHGCsp) if you wish to perform the SHG control in the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis). When not performing the SHG control, set to “0”.
0 to 999 (rad/s)
Dual feed back control time constant
Set the control time constant in dual feed back. When “0” is set, the actual value that is set is 1ms. The higher the time constant is, the closer it gets to the semi-closed control, so the limit of the position loop gain is raised.
0 to 9999 (ms)
Dual feedback control non-sensitive band
Set the non-sensitive band in the dual feedback control. Set to “0” as a standard.
0 to 9999 (µm)
Excessive error detection width in special control
Set the excessive error detection width when servo ON in a special control (initial absolute position setting, stopper control, etc.). If “0” is set, excessive error detection won’t be performed when servo ON during a special control.
0 to 32767 (mm)
Overrun detection width in closed loop control
Set the overrun detection width in the full-closed loop control. If the gap between the motor end detector and the linear scale (machine end detector) exceeds the value set by this parameter, it is judged to be overrun and Alarm 43 will be detected. When “-1” is set, the alarm detection won’t be performed. When “0” is set, overrun is detected with a 2mm width.
-1 to 32767 (mm)
2248 SV048 EMGrt · 2249 SV049 PGN1sp

No. Items Details Setting range
Max. gate off delay time after emergency stop
Set a length of time from the point when the emergency stop is input to the point when READY OFF is compulsorily executed. Normally, set the same value as the absolute value of SV056. In preventing the vertical axis from dropping, the gate off is delayed for the length of time set by SV048 if SV055’s value is smaller than that of SV048.
0 to 20000 (ms)
Deceleration time constant at emergency stop
In the vertical axis drop prevention control, set the time constant used for the deceleration control at emergency stop. Set a length of time that takes from rapid traverse rate (rapid) to stopping. Normally, set the same value as the rapid traverse acceleration/deceleration time constant. When executing the synchronous operation, put the minus sign to the settings of both of the master axis and slave axis.
-20000 to 20000 (ms)
When performing the SHG control, set this with S003 (PGN1) and SV004 (PGN2). When not performing the SHG control, set to “0”.
0 to 999 (rad/s)
SHG control gain in spindle synchronous control
Set this with SV049 (PGN1sp) and SV050 (PGN2sp) if you wish to perform the SHG control in the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis). When not performing the SHG control, set to “0”.
0 to 999 (rad/s)
Collision detection torque estimating gain
Set the torque estimating gain when using the collision detection function. After setting as SV035/bitF(clt)=1 and performing acceleration/deceleration, set the value displayed in MPOS of the NC servo monitor screen. Set to “0” when not using the collision detection function.
When using the collision detection function, set the collision detection level during the G0 feeding. If “0” is set, none of the collision detection function will work.
0 to 999 (Stall [rated] current %)
D/A output channel 1 data No.
Input the data number you wish to output to D/A output channel. In the case of MDS-C1-V2, set the axis on the side to which the data will not be output to “-1”.
D/A output channel 2 data No.
D/A output channel 1 output scale
Set the scale with a 1/256 unit. When “0” is set, output is done with the standard output unit.
D/A output channel 2 output scale
2265 SV065 Not used. Set to “0”. 0

(2) Initial setting value
52 HC 102 HC 152 HC 202 HC 352 HC 452 HC 702 HC 902 Drive unit
capacity 05 10 20 20 35 45 70 90
SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 100 150 150 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 2048 SV010 IDA 2048 SV011 IQG 512 512 512 256 256 256 200 200 SV012 IDG 512 256 256 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xxB0 xxB1 xxB2 xxB3 xxB4 xxB5 xxB6 xxB7 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0
(a) HC**/HC**R series · Motor HC

52 HC 102 HC 152 HC 202 HC 352 HC 452 HC 702 HC 902 Drive unit
capacity 05 10 20 20 35 45 70 90
SV033 SSF2 0000 SV034 SSF3 0003 SV035 SSF4 0000 0000 0040 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 0 0 10240 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0
Motor HC

53 HC 103 HC 153 HC 203 HC 353 HC 453 HC 703 HC 103R HC 153R HC 203R HC 353R Drive unit
capacity 05 10 20 35 45 70 90 10 10 20 35
SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 100 15 15 20 40 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 2048 4096 SV010 IDA 2048 4096 SV011 IQG 256 SV012 IDG 512 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xxC0 xxC1 xxC2 xxC3 xxC4 xxC5 xxC6 xxE1 xxE2 xxE3 xxE4 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0
Motor HC

53 HC 103 HC 153 HC 203 HC 353 HC 453 HC 703 HC 103R HC 153R HC 203R HC 353R Drive unit
capacity 05 10 20 35 45 70 90 10 10 20 35
SV033 SSF2 0000 SV034 SSF3 0003 0000 SV035 SSF4 0000 0000 0040 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0
SV040 LMCT 0 0 0 1024 0 1024 0 1024 0 1024 0
SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0
Motor HC

Motor HA 40N HA 80N HA 100N HA 200N HA 300N HA 700N HA 900N Drive unit
capacity 05 10 20 35 45 70 90
SV001 PC1 - SV002 PC2 - SV003 PGN1 33 25 25 SV004 PGN2 0 SV005 VGN1 150 250 250 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 2048 SV010 IDA 2048 SV011 IQG 512 512 256 256 256 200 200 SV012 IDG 512 256 256 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xx00 xx01 xx02 xx03 xx04 xx05 xx06 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0
(b) HA**N series

Motor HA 40N HA 80N HA 100N HA 200N HA 300N HA 700N HA 900N Drive unit
capacity 05 10 20 35 45 70 90
SV033 SSF2 0000 SV034 SSF3 0000 SV035 SSF4 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0

Motor HA 43N HA 83N HA 93N HA 103N HA 203N HA 303N HA 703N Drive unit
capacity 05 10 20 35 45 70 90
SV001 PC1 - SV002 PC2 - SV003 PGN1 33 25 SV004 PGN2 0 SV005 VGN1 150 250 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 2048 SV010 IDA 2048 SV011 IQG 256 200 SV012 IDG 512 256 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xx80 xx81 xx8A xx82 xx83 xx84 xx85 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0

Motor HA 43N HA 83N HA 93N HA 103N HA 203N HA 303N HA 703N Drive unit
capacity 05 10 20 35 45 70 90
SV033 SSF2 0000 SV034 SSF3 0000 SV035 SSF4 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0

13 HA 053N HA 13N HA 23N HA 33N Drive unit
Motor HA 053 HA
capacity 01 03 03
SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 70 100 100 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 2048 SV010 IDA 2048 SV011 IQG 256 224 224 SV012 IDG 256 224 224 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 10 10 - SV020 RNG2 10 10 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP 338C 338D xx8C xx8D xx8E xx8F SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0 (Note) The HA053 and HA13 are dedicated for the MDS-B-Vx.

13 HA 053N HA 13N HA 23N HA 33N Drive unit
Motor HA 053 HA
capacity 01 03 03
SV033 SSF2 0000 SV034 SSF3 0000 SV035 SSF4 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0 (Note) The HA053 and HA13 are dedicated for the MDS-B-Vx.

Motor HA 50L HA 100L HA 150L HA 200L HA 300L HA 500L HA- A11KL
capacity 05 10 10 20 35 45 110 150
SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 30 50 150 150 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 2048 SV010 IDA 2048 SV011 IQG 512 256 256 512 512 SV012 IDG 512 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 3 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xx20 xx21 xx2A xx22 xx23 xx24 xx27 xx28 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0
(c) HA**L series · HA- A15KL Drive unit

Motor HA 50L HA 100L HA 150L HA 200L HA 300L HA 500L HA- A11KL
capacity 05 10 10 20 35 45 110 150
SV033 SSF2 0000 SV034 SSF3 0000 SV035 SSF4 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0
HA- A15KL Drive unit

Motor HA 53L HA 103L HA 153L HA 203L HA 303L HA 503L Drive unit
capacity 10 20 20 35 45 70
SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 30 50 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 2048 SV010 IDA 2048 SV011 IQG 512 256 256 SV012 IDG 512 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xx30 xx31 xx3A xx32 xx33 xx34 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0 SV033 SSF2 0000

Motor HA 53L HA 103L HA 153L HA 203L HA 303L HA 503L Drive unit
capacity 10 20 20 35 45 70
SV034 SSF3 0000 SV035 SSF4 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0

(1) MDS-B-SVJ2
(a) D/A output specifications

Item Explanation No. of channels 2ch Output cycle 888µs (min. value) Output precision 8bit Output voltage range
GND = pin 1,11 Function Offset amount adjustment function Output clamp function Low path filter function Option Relay terminal: MR-J2CN3TM Connect from the CN3 connector using the SH21 cable as a lead-in wire. CN3 Connector Pin Signal Pin Signal

1 LG 11 LG 2 12 3 SG 13 MBR 4 MO1 14 MO2 5 COM 15 MC 6 16 7 17 8 18 9 19 10 VDD 20 EMGX

(b) Setting the output data
Set the No. of the data to be outputted to each D/A output channel.
# No. Abbrev Parameter name 2261 SV061 DA1NO D/A output channel 1 data No. 2262 SV062 DA2NO D/A output channel 2 data No.
No. Output data Standard output unit
cycle 0 0V test output For offset amount adjustment 1 Speed feedback 1000rpm / 2V 888µs
2 Current feedback Stall (rated)
100% / 2V 888µs
3 Speed command 1000rpm / 2V 888µs
4 Current command Stall (rated)
100% / 2V 888µs
5 V-phase current value 10A / V 888µs 6 W-phase current-value 10A / V 888µs
7 Estimated disturbance torque Stall (rated)
100% / 2V 888µs
8 Collision detection disturbance torque
100% / 2V 888µs
9 Position feedback (stroke) 100mm / V 3.55ms 10 Position feedback (pulse) 10µm / V 3.55ms 11 Position droop mm / V 3.55ms 12 Position droop (x10) 100µm / V 3.55ms 13 Position droop (x100) 10µm / V 3.55ms 14 Feedrate (F∆T) 10000(mm/min) / V 888µs 15 Feedrate (F∆T x 10) 1000(mm/min) / V 888µs 16 Model position droop mm / V 3.55ms 17 Model position droop (x10) 100µm / V 3.55ms 18 Model position droop (x100) 10µm / V 3.55ms 19 q-axis current cumulative value – 888µs 20 d-axis current cumulative value – 888µs 21 Motor load level 100% / 5V 113.7ms 22 Amplifier load level 100% / 5V 113.7ms 23 Regenerative load level 100% / 5V 910.2ms 24 PN bus wire voltage 50V / V (1/50) 888µs 25 Speed cumulative item – 888µs
26 Cycle counter 0-5V (Regardless of resolution) 888µs
27 Excessive error detection amount mm / V 3.55ms
28 Collision detection estimated torque
100% / 2V 888µs
29 Position command (stroke) 100mm / V 3.55ms 30 Position command (pulse) 10µm / V 3.55ms 31 to 99 - 100 5V test output - -
101 Saw-tooth wave test output -5 to 5V Cycle: 113.7ms 888µs
102 Rectangular wave test output 0 to 5V Cycle: 227.5ms 888µs
103 to Setting prohibited
Output · Stall (rated) · Stall (rated)

(c) Setting the output scale
When “0“ is set, the output will be made with the standard output unit. To change the output unit, set a value other than “0”. The scale is set with a 1/256 unit. When 256 is set, the unit will be the same as the standard output.
# No. Abbrev Parameter name 2263 SV063 DA1MPY D/A output channel 1 output scale 2264 SV064 DA2MPY D/A output channel 2 output scale (Example 1) When SV061 = 5, SV063 = 2560
The V-phase current value will be output with 1 A/V unit to D/A output ch.1. (Example 2) When SV063 = 11, SV064 = 128
The position droop will be output with a 2mm/Vunit to D/A output ch.2.

(2) MDS-C1-Vx, MDS-B-Vx, MDS-B-Vx4
(a) D/A Output specifications

Item Explanation No. of channels 2ch Output cycle 888µs (min. value) Output precision 8bit Output voltage 0V to 2.5V to +5V Output scale setting
CN9 connector MO1 = pin 9 MO2 = pin 19
GND = pin 1,11 Phase current feed back output function L-axis U-phase current FB : pin 7 L-axis V-phase current FB : pin 17 M-axis U-phase current FB : pin 6
M-axis V-phase current FB : pin 16 Option An drive unit with 2 axes also has 2 channels for D/A output. Therefore, set the output data of the axis (SV061,62), which is not observed, to “-1”.

1 LG 11 LG 2 12 3 13 4 14 5 15 6 MUIFB 16 MVIFB 7 LUIFB 17 LVIFB 8 18 9 MO1 19 MO2 10 20

(b) Setting the output data
Set the No. of the data to be outputted to each data D/A output channel.

# No. Abbrev Parameter name 2261 SV061 DA1NO D/A output channel 1 data No. 2262 SV062 DA2NO D/A output channel 2 data No.
For a drive unit. with 2 axes (MDS-C1-V2). Set for the parameter of the axis which is not used.
1 Current command Stall% 131 Stall 100% / V 3.55ms 2 – 3 Current feedback Stall% 131 Stall 100% / V 3.55ms 4 – 5 –
14 Collision detection estimated torque Stall% 131 Stall 100% / V 3.55ms
15 Collision detection disturbance torque Stall% 131 Stall 100% / V 3.55ms
(To be continued to the next page)

(Continued from the previous page)
No. Output data Standard output
scale (Setting values in
77 Estimated disturbance torque Internal unit
125 Saw-tooth wave test output 0V to 5V 0 (256) Cycle: 227.5ms 888µs
126 Rectangular wave test output 0V to 5V 0 (256) Cycle: 1.7ms 888µs
127 2.5V (data 0) test output 2.5V 0 (256) – 888µs
(c) Setting the output scale
# No. Abbrev Parameter name 2263 SV063 DA1MPY D/A output channel 1 output scale 2264 SV064 DA2MPY D/A output channel 2 output scale Usually, the standard setting value is set for the output scale (SV063, SV 064). When “0” is set, the output will be made as well as when “256” is set.
SV063 5 [V] DATA x 256 x 256 (8bit) + 2.5 [V] (offset) = Output voltage [V]
(Example) When outputting the current FB with 100%/V–stall (SV061=3, SV063=131)
131 5 100 x 256 x 256 + 2.5 = 3.499 [V]

The servo drive unit has internal electronic gears. The command value from the NC is converted into a detector resolution unit to carry out position control. The electronic gears are single gear ratios calculated from multiple parameters as shown below. However, each value (ELG1, ELG2) must be less than 32767.
If the value overflows, the initial parameter error (alarm 37) or error parameter No. 2301 will be output.
If an alarm occurs, the mechanical specifications and electrical specifications must be revised so that the electronic gears are within the specifications range.
ELG1 RNG1 x PC2 ELG2 = PIT x PC1 x IUNIT (Reduced fraction)
ELG1 PGN x RNG2 x PC2 ELG2 = 30 x RNG1 x PC1 (Reduced fraction)
IUNIT = 2/NC command unit (µm)
When the above is calculated, the following conditions must be satisfied.
ELG2 ≤ 32767
·

When the motor is to rotate in the clockwise direction (looking from the load side) at the command for the + direction, the command direction is CW. Conversely, when the motor is to rotate in the counterclockwise direction, the command direction is CCW. This rotation direction can be set with the CNC machine parameters. Note that the meaning of the ± will differ for some servo parameters according to this motor rotation direction. The servo parameters affected by CW/CCW are shown below.
SV016 (LMC1), SV041 (LMC2) (When different values are set for SV016 and SV041) SV031 (OVS1), SV042 (OVS2) (When different values are set for SV031 and SV042) <Example> If the lost motion compensation amount is to be changed according to the direction,
the compensation amount at the quadrant changeover point of each arc where the lost motion compensation is applied will be as shown below according to the command polarity.

The Y axis command direction changes from the + to – direction.
The X axis command direction changes from the + to – direction.
The X axis command direction changes from the – to + direction.
The Y axis command direction changes from the – to + direction.
(Note) The setting value for the parameter is “0” or “-1”, the compensation amount is determined as
shown below.


For parameters indicated with a (PR) in the table, turn the NC power OFF after setting. The setting is validated after the power is turned ON again.
No. Items Details Setting range
Set spindle rotation speed for maximum motor rotation speed with gears 00, 01, 10, 11. (Set the spindle rotation speed for the S analog output 10V.)
0 to 99999 (r/min)
Set maximum spindle speed with gears 00, 01, 10, 11. Set the value that is equal to or larger than "slimit" value. By comparing the S command value of gear 1 to 4, a spindle gear shift command will be output automatically.
Set spindle rotation speed for gear shifting with gears 00, 01, 10, 11.
0 to 32767 (r/min)
(Note) Setting too large value may cause a gear
nicks when changing gears.
Set maximum spindle rotation speed during tap cycle with gears 00, 01, 10, 11.
0 to 99999 (r/min)
Set time constants for constant inclination synchronized tapping for gears 00, 01, 10, 11 (linear acceleration/deceleration pattern).
1 to 5000 (ms)

Relationship between spindle limit rotation speed and maximum spindle rotation speed
Spindle rotation speed (r/min)
0 smax1 slimt1 smax2 slimt2 smax(n) slimt(n)
Limit rotation speed of gear 1 (Parameter setting)
Maximum rotation speed of gear 1 (Parameter setting)
Set "0" for any unused gears.
Relation between the spindle limit rotation speed and the spindle tap time constant (for the constant inclination synchronized tapping)
Spindle rotation speed (r/min) Spindle rotation speed (r/min)

# Items Details Setting range
3021 sori Orientation rotation speed
Set the spindle orientation rotation speed. Set the rotation speed for when the spindle rotates at the constant rotation speed.
0 to 32767 (r/min)
3022 sgear Encoder gear ratio
Set the gear ratio of the spindle to the encoder. 0: 1/1 1: 1/2 2: 1/4 3: 1/8
3023 smini Minimum rotation speed
Set the minimum rotation speed of the spindle. If an S command instructs the rotation speed below this setting, the spindle rotates at the minimum rotation speed set with this parameter.
0 to 32767 (r/min)
Set the type of the spindle to be connected.
3025 enc-on Spindle encoder
Set connection information of the spindle encoder.
3026 cs_ori Selection of winding in orientation mode
3027 cs_syn Selection of winding in spindle synchronou s mode
3028 sprcmm L system tap cycle spindle forward run/ reverse run M command
Set the M code of the spindle forward run/reverse run command. High-order three digits :
The spindle forward run command's M code is set. Low-order three digits :
The spindle reverse run command's M code is set.

# Items Details Setting range
(Unit) 3037 3038 3039 3040
tapt 21 22 23 24
Synchronized tapping Switching spindle rota- tion speed 2
Set the spindle rotation speed at which the step-2 acceleration/deceleration time constant is to be switched at gear 00, 01, 10, or 11.
0 to 99999 (r/min)
3041 3042 3043 3044
tapt 21 22 23 24
Synchronized tapping Switching time constant 2
Set the time constant to reach Synchronized tapping switching spindle rotation speed 2 (#3037 to #3040) at gear 00, 01, 10, or 11.
1 to 5000 (ms)
3045 3046 3047 3048
tapt 31 32 33 34
Synchronized tapping Switching time constant 3
Set the time constant to reach the maximum rotation spindle speed (#3005 to #3008) at gear 00, 01, 10, or 11.
1 to 5000 (ms)
3049 spt Spindle synchroniza- tion acceleration/ deceleration time constant
Set the acceleration/deceleration time constant for when the spindle synchronization command's rotation speed changes during spindle synchronous control.
0 to 9999 (ms)
3050 sprlv Spindle synchroniza- tion rotation speed attainment level
The spindle rotation speed synchronization complete signal will turn ON when the difference of the reference spindle and synchronous spindle actual rotation speeds is less than the level set for the synchronous spindle rotation speed command value during spindle synchronous control.
0 to 4095 (pulse) (1 pulse = 0.088°)
3051 spplv Spindle phase synchroniza- tion attainment level
The spindle phase synchronization complete signal will turn ON when the phase difference of the reference spindle and synchronous spindle is less than the set level during spindle phase synchronization control.
0 to 4095 (pulse) (1 pulse = 0.088°)
3052 spplr Spindle motor spindle relative polarity
Set the spindle motor and spindle's relative polarity.
Spindle CW rotation at motor CW rotation
: Positive polarity Spindle CCW rotation at motor CW rotation
: Negative polarity
3053 sppst Spindle encoder Z -phase position
Set the deviation amount from the spindle's reference position to the spindle encoder's Z phase. The deviation amount is obtained using the clockwise direction looking from the front of the spindle as the positive direction.

# Items Details Setting range
3054 sptc1 Spindle synchroniza- tion multi-step acceleration/ deceleration changeover speed 1
Set the spindle speed for changing the 1st step's acceleration/deceleration time constant.
0 to 99999 (r/min)
3055 sptc2 Spindle synchroniza- tion multi-step acceleration/ deceleration changeover speed 2
Set the spindle speed for changing the 2nd step's acceleration/deceleration time constant.
0 to 99999 (r/min)
3056 sptc3 Spindle synchroniza- tion multi-step acceleration/ deceleration changeover speed 3
Set the spindle speed for changing the 3rd step's acceleration/deceleration time constant.
0 to 99999 (r/min)
3057 sptc4 Spindle synchroniza- tion multi-step acceleration/ deceleration changeover speed 4
Set the spindle speed for changing the 4th step's acceleration/deceleration time constant.
0 to 99999 (r/min)
3058 sptc5 Spindle synchroniza- tion multi-step acceleration/ deceleration changeover speed 5
Set the spindle speed for changing the 5th step's acceleration/deceleration time constant.
0 to 99999 (r/min)
3059 sptc6 Spindle synchroniza- tion multi-step acceleration/ deceleration changeover speed 6
Set the spindle speed for changing the 6th step's acceleration/deceleration time constant.
0 to 99999 (r/min)
(Unit)

# Items Details Setting range
3060 sptc7 Spindle synchroniza- tion multi-step acceleration/ deceleration changeover speed 7
Set the spindle speed for changing the 7th step's acceleration/deceleration time constant.
0 to 99999 (r/min)
3061 spdiv1 Magnification for time constant changeover speed 1
Set the acceleration/deceleration time constant between the spindle synchronization multi-step acceleration/deceleration changeover speed 1 (sptc1) to the spindle synchronization multi-step acceleration/deceleration changeover speed 2 (sptc2) as a magnification in respect to the spindle synchronization acceleration/deceleration time constant (spt).
3062 spdiv2 Magnification for time constant changeover speed 2
Set the acceleration/deceleration time constant between the spindle synchronization multi-step acceleration/deceleration changeover speed 2 (sptc2) to the spindle synchronization multi-step acceleration/deceleration changeover speed 3 (sptc3) as a magnification in respect to the spindle synchronization acceleration/deceleration time constant (spt).
3063 spdiv3 Magnification for time constant changeover speed 3
Set the acceleration/deceleration time constant between the spindle synchronization multi-step acceleration/deceleration changeover speed 3 (sptc3) to the spindle synchronization multi-step acceleration/deceleration changeover speed 4 (sptc4) as a magnification in respect to the spindle synchronization acceleration/deceleration time constant (spt).
3064 spdiv4 Magnification for time constant changeover speed 4
Set the acceleration/deceleration time constant between the spindle synchronization multi-step acceleration/deceleration changeover speed 4 (sptc4) to the spindle synchronization multi-step acceleration/deceleration changeover speed 5 (sptc5) as a magnification in respect to the spindle synchronization acceleration/deceleration time constant (spt).
3065 spdiv5 Magnification for time constant changeover speed 5
Set the acceleration/deceleration time constant between the spindle synchronization multi-step acceleration/deceleration changeover speed 5 (sptc5) to the spindle synchronization multi-step acceleration/deceleration changeover speed 6 (sptc6) as a magnification in respect to the spindle synchronization acceleration/deceleration time constant (spt).
(Unit)

# Items Details Setting range
3066 spdiv6 Magnification for time constant changeover speed 6
Set the acceleration/deceleration time constant between the spindle synchronization multi-step acceleration/deceleration changeover speed 6 (sptc6) to the spindle synchronization multi-step acceleration/deceleration changeover speed 7 (sptc7) as a magnification in respect to the spindle synchronization acceleration/deceleration time constant (spt).
3067 spdiv7 Magnification for time constant changeover speed 7
Set the acceleration/deceleration time constant for the spindle synchronization multi-step acceleration/deceleration changeover speed 7 (sptc7) and higher as a magnification in respect to the spindle synchronization acceleration/deceleration time constant (spt).
3068 symtm1 Phase synchroniza- tion start confirmation time
Set the time to confirm that synchronization is attained before phase synchronization control is started. When "0" is set, the time will be 2 seconds. When "100" or less is set, the time will be 100ms.
0 to 9999 (ms)
3069 symtm2 Phase synchroniza- tion end confirmation time
Set the time to wait for phase synchronization control to end as the time for the rotation speed to reach the attainment range. When "0" is set, the time will be 2 seconds. When "100" or less is set, the time will be 100ms.
0 to 9999 (ms)
3070 syprt Phase synchroniza- tion speed
Set the fluctuation amount to change the synchronous spindle rotation speed during phase synchronization control as the command speed and rate. When "0" is set, the amount will be 100%.
(Not used.)
(Not used.)
(Unit)

8.2 MDS-B-SPJ2 For parameters marked with a (PR) in the tables, turn the NC power OFF after setting. The parameters will be valid after the power is turned ON again. The valid spindle parameters will differ according to the motor and amplifier type. Follow the correspondence table given below, and set the correct parameters. The spindle parameter setting and display method will differ according to the NC being used, so refer to Instruction Manual for each NC and the following spindles.
MELDAS AC Servo and Spindle MDS-A Series MDS-B Series Specifications Manual ...BNP-B3759
The "fixed control constants" and "fixed control bits" in this section are set by Mitsubishi.
! Do not make remarkable adjustments or changes of the parameters as the operation may
become unstable.
! In the explanation on bits, set all bits not used, including blank bits, to “0”.
No. Items Details Setting
3201 SP001 PGM Magnetic detector and motor built- in encoder orientation- mode position loop gain
As the set value is larger, the orientation time becomes shorter and servo rigidity is increased. On the contrary, however, vibration is increased and the machine becomes likely to overshoot.
0 to 1000 (0.1 1/s)
3202 SP002 PGE Encoder orientation-mo de position loop gain
As the set value is larger, the orientation time becomes shorter and servo rigidity is increased. On the contrary, however, vibration is increased and the machine becomes likely to overshoot.
0 to 1000 (0.1 1/s)
SP003 Not used. Set to “0”. 0 0
3204 SP004 OINP Orientation in-position width
Set the position error range in which an orientation completion signal is output.
SP005 OSP Orientation mode changing speed limit value
Set the motor speed limit value to be used when the speed loop is changed to the position loop in orientation mode. When this parameter is set to "0", SP017 (TSP) becomes the limit value.
0 to 32767 (r/min)
3206 SP006 CSP Orientation mode dece- leration rate
As the set value is larger, the orientation time becomes shorter. On the contrary, however, the machine becomes likely to overshoot.
3207 SP007 OPST In-position
Set the stop position for orientation. Set the value by dividing 360° by 4096.
shift amount for orientation
SP008 Not used. Set to "0". 0 0
3209 SP009 PGT Synchronous tapping position loop gain
Set the spindle position loop gain in synchronous tapping mode.
1 to 100 (1/s)
Standard · range · setting

No. Items Details Setting
3210 SP010 PGS Spindle synchronous position loop gain
Set the spindle position loop gain in spindle synchronization mode.
1 to 100 (1/s)
Use not possible. 0 0
SP017 TSP Maximum motor speed
Set the maximum motor speed of the spindle.
1 to 32767 (r/min)
SP018 ZSP Motor zero speed
Set the motor speed for which zero-speed output is performed.
1 to 1000 (r/min)
SP019 CSN1 Speed cushion 1 Set the time constant for a speed
0 to 32767 (10ms)
command from "0" to the maximum speed. (This parameter is invalid in position loop mode.)
SP020 SDTS Speed detection set value
Set the motor speed so for which speed detection output is performed. Usually, the setting value is 10% of SP017 (TSP).
0 to 32767 (r/min)
SP021 TLM1 Torque limit 1 Set the torque limit rate for torque limit signal 001.
SP022 VGNP1 Speed loop gain
Set the speed loop proportional gain in speed control mode. When the gain is increased, response is improved but vibration and sound become larger.
0 to 1000 (1/s)
proportional term under speed control
SP023 VGNI1 Speed loop gain
Set the speed loop integral gain in speed control mode. Usually, set a value in proportion to SP022 (VGNP1).
0 to 1000 (0.1 1/s)
integral term under speed control
SP024 Not used. Set to "0". 0 0
SP025 GRA1 Spindle gear teeth count 1
Set the number of gear teeth of the spindle corresponding to gear 000.
SP026 GRA2 Spindle gear teeth count 2
Set the number of gear teeth of the spindle corresponding to gear 001.
SP027 GRA3 Spindle gear teeth count 3
Set the number of gear teeth of the spindle corresponding to gear 010.
SP028 GRA4 Spindle gear teeth count 4
Set the number of gear teeth of the spindle corresponding to gear 011.
SP029 GRB1 Motor shaft gear teeth count 1
Set the number of gear teeth of the motor shaft corresponding to gear 000.
SP030 GRB2 Motor shaft gear teeth count 2
Set the number of gear teeth of the motor shaft corresponding to gear 001.
SP031 GRB3 Motor shaft gear teeth count 3
Set the number of gear teeth of the motor shaft corresponding to gear 010.
SP032 GRB4 Motor shaft gear teeth count 4
Set the number of gear teeth of the motor shaft corresponding to gear 011.


F E D C B A 9 8 poff hzs ront
7 6 5 4 3 2 1 0 sftk dflt 1a2m
bit Name Meaning when set to 0 Meaning when set to 1
0 1a2m 1 amplifier 2 motor function: Invalid 1 amplifier 2 motor function: Valid 1 dflt Default motor: Main Default motor: Sub 2 sftk SF-TK card invalid SF-TK card valid 3 4 5 6 7 8 9 A B C ront D E hzs F poff
7 6 5 4 3 2 1 0 mts1
bit Name Meaning when set to 0 Meaning when set to 1
Special motor constant setting valid 1 2 3 4 5 6 7 8 9 A B C D E F
(Note1) Always turn the bit2 at the same time to use

No. Items Details Setting
SP035 SFNC3 Spindle function3
Set the spindle function 3 in bit units.
0000 to FFFF HEX setting
7 6 5 4 3 2 1 0 hbsd hwid
(Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
H-coil wide-range constant output valid 1 2 hbsd H-coil base slide invalid H-coil base slide valid 3 4 5 6 7 8 9 A B C D E F
0 hwid H-coil wide-range constant output invalid
SP036 SFNC4 Spindle function 4
Set the spindle function 4 in bit units.
F E D C B A 9 8 dslm dssm
7 6 5 4 3 2 1 0 enc2 enc1 mag2 mag1 plg2 plg1 (Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1 0 plg1 PLG of motor 1 valid PLG of motor 1 invalid 1 plg2 PLG of motor 2 valid PLG of motor 2 invalid 2 mag1 MAG of motor 1 valid MAG of motor 1 invalid 3 mag2 MAG of motor 2 valid MAG of motor 2 invalid 4 enc1 ENC of motor 1 valid ENC of motor 1 invalid 5 enc2 ENC of motor 2 valid ENC of motor 2 invalid 6 7 8 dssm Speedometer valid Speedometer invalid 9 dslm Load meter valid Load meter invalid A B C D E F
Standard · range · setting


F E D C B A 9 8 nstv
7 6 5 4 3 2 1 0 plgo enco
bit Name Meaning when set to 0 Meaning when set to 1
Encoder orientation valid 1 2 plgo PLG orientation invalid PLG orientation valid 3 4 5 6 7
Monitoring only in position loop or orientation-mode 9 A B C D E F
F E D C B A 9 8 oplp
7 6 5 4 3 2 1 0 pftm alty
bit Name Meaning when set to 0 Meaning when set to 1
Thread cutting position data valid 3 4 5 6 7 8 9 A B C D E


Set the amplifier type. Set each amplifier type or "0". This parameter corresponds to MDS-B-SPJ2.
SP040 MTYP Motor type 0000 to FFFF HEX setting
This is valid when SP034 (SFNC2) bit 0 is set to 0. Refer to the following standard motors, and set the applicable motor number.

No. Items Details Setting
SP041 PTYP Power supply type
When this unit is a signal connection axis with power supply unit, set this parameter. Set "0" for this parameter for the unit which is not a signal connection axis.
0000 to FFFF HEX setting
Select a value from the following table according to the regenerative resistance being used.
(Note 1) This setting is used when using one
value (Ω)
0000 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 2A00 2B00 2C00
– Not connected FCUA-RB04 FCUA-RB075 FCUA-RB15 FCUA-RB22 FCUA-RB37 FCUA-RB55 FCUA-RB75/2 R–UNIT–1 R–UNIT–2 R–UNIT–3 R–UNIT–4 R–UNIT–5
– – 200 100 60 40 25 20 30/15 30 15 15 10 10
– – 60 80 120 155 185 340 340/680 700 700 2100 2100 3100
FCUA-RB75/2 and when using two in parallel.
SP042 Not used. Set to “0”. 0 0
SP043 Not used. Set to “0”. 0 0
Set a frequency of data communication with NC.
SP045 Not used. Set to “0”. 0 0
SP046 CSN2 Speed command dual cushion
For an acceleration/deceleration time constant defined in SP019 (CSN1) , this parameter is used to provide smooth movement only at the start of acceleration/deceleration. As the value of this parameter is smaller, it moves smoother but the acceleration/deceleration time becomes longer. To make this parameter invalid, set "0".
Set the reset hysteresis width for a speed detection set value defined in SP020 (SDTS).
0 to 1000 (r/min)

No. Items Details Setting
SP048 SUT Speed reach range
Set the speed deviation rate with respect to the commanded speed for output of the speed reach signal.
3249 SP049 TLM2 Torque limit 2 Set the torque limit rate for the torque limit signal 010.
3250 SP050 TLM3 Torque limit 3 Set the torque limit rate for the torque limit signal 011.
3251 SP051 TLM4 Torque limit 4 Set the torque limit rate for the torque limit signal 100.
3252 SP052 TLM5 Torque limit 5 Set the torque limit rate for the torque limit signal 101.
3253 SP053 TLM6 Torque limit 6 Set the torque limit rate for the torque limit signal 110.
3254 SP054 TLM7 Torque limit 7 Set the torque limit rate for the torque limit signal 111.
Set the timer value until the excessive speed deviation alarm is output. The value of this parameter should be longer than the acceleration/deceleration time.
0 to 60 (s) 12
3256 SP056 PYVR Variable excitation (min value)
Set the minimum value of the variable excitation rate. Select a smaller value when gear noise is too high. However, a larger value is effective for impact response.
SP057 STOD Fixed control
Set by Mitsubishi. Set "0" unless designated in particular.
Not used. Set to "0". 0 0
SP063 OLT Overload alarm detection time
Set the time constant for detection of the motor overload alarm.
0 to 1000 (s)
SP064 OLL Overload alarm detection level
Set the detection level of the motor overload alarm.
SP065 VCGN1 Target value of
Set the magnification of speed loop proportional gain with respect to SP022 (VGNP1) at the maximum motor speed defined in SP017 (TSP).
variable speed loop proportional gain
Set the speed for starting change of speed loop proportional gain.
0 to 32767 (r/min)
starting speed of variable speed loop proportional gain
SP022× (SP065/100)
SP066 SP017


Set the speed for starting change of current loop gain.
Set the speed for ending change of current loop gain.
SP069 VIGN Target value of variable current loop gain
Set the magnification of current loop gain (torque component and excitation component) for a change ending speed defined in SP068 (VIGWB). When this parameter is set to "0", the magnification is 1.
0 to 6000 6001 to 8000 5000 8000 45 8001 or more 5000 10000 64
Set by Mitsubishi. Set "0" unless designated in particular.


Set by Mitsubishi. Set "0" unless designated in particular.
Set the minimum value of variable torque limit at deceleration.
SP088 DIQN Speed for starting change of variable torque limit magnifica- tion at deceleration
Set the speed for starting change of torque limit value at deceleration.
Set by Mitsubishi. Set "0" unless designated in particular.
Set by Mitsubishi. Set "0" unless designated in particular.

No. Items Details Setting
SP096 EGAR Encoder gear
Set the gear ratio between the spindle end and the encoder end (except for the motor-built-in encoder) as indicated below.
0 1 : 1 1 1 : 1/2 2 1 : 1/4 3 1 : 1/8 4 1 : 1/16
Set the orientation specifications in bit units.
0000 to FFFF HEX setting
F E D C B A 9 8 tlet
7 6 5 4 3 2 1 0 fdir pyfx dmin odi2 odi1
(Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1 0 odi1
Orientation rotation direction 00: Previous (the direction in which the motor has so far rotated under speed control) 01: Forward rotation 10: Backward rotation 11: Prohibited (Same as setting value = 10)
2 dmin Dummy in-position invalid
3 pyfx Excitation min. (50%) during orientation servo lock invalid
Excitation min. (50%) during orientation servo lock valid 4
Encoder detector polarity: – 6 7 8 tlet Turret indexing invalid Turret indexing valid 9 A B C D E F
SP098 VGOP Speed loop
Set the speed loop proportional gain in orientation mode. When the gain is increased, rigidity is improved in the orientation stop but vibration and sound become larger.
0 to 1000 (1/s)
gain propor- tional term in orientation mode
SP099 VGOI Orientation mode speed loop gain integral term
Set the speed loop integral gain in orientation mode.
0 to 1000 (0.1 1/s)
Set the a loop gain delay advance gain in orientation mode. When this parameter is set to "0", PI control is exercised.
0 to 1000 (0.1 1/s)
mode speed loop gain delay advance term

No. Items Details Setting
SP101 DINP Orientation advance in-position width
When using the orientation in-position advance function, set the in-position width that is larger than the normal in-position width defined in SP004 (OINP).
Set the excessive error width in orientation mode.
1 to 32767 (1/4 pulse) (1 pulse= 0.088°)
error value in orientation mode
SP103 FTM Index positioning completion OFF time timer
Set the time for forcedly turn OFF the index positioning completion signal (different from the orientation completion signal) after the leading edge of the indexing start signal.
1 to 10000 (ms)
SP104 TLOR Torque limit value for orientation servo locking
Set the torque limit value for orientation in-position output. If the external torque limit signal is input the torque limit value set by this parameter is made invalid.
SP105 IQG0 Current loop gain magnifica- tion 1 in orientation mode
Set the magnification for current loop gain (torque component) at orientation completion.
3306 SP106 IDG0 Current loop gain magnifica- tion 2 in orientation mode
Set the magnification for current loop gain (excitation component) at orientation completion.
3307 SP107 CSP2 Deceleration rate 2 in orientation mode
Set the deceleration rate in orientation mode corresponding to the gear 001. When this parameter is set to "0", same as SP006 (CSP).
3308 SP108 CSP3 Deceleration rate 3 in orientation mode
Set the deceleration rate in orientation mode corresponding to the gear 010. When this parameter is set to "0", same as SP006 (CSP).
SP109 CSP4 Deceleration rate 4 in orientation mode
Set the deceleration rate in orientation mode corresponding to the gear 011. When this parameter is set to "0", same as SP006 (CSP).
SP110 WCML Turret index
The integer magnification (gear ratio 1 : N) for the index position command (0 to 359) is set.
0 to 32767 (fold)
3311 SP111 WDEL Turret index deceleration magnifica- tion
The magnification for the orientation deceleration rate is set using 256 as 1.
0 to 32767 (1/256 -fold)
3312 SP112 WCLP Turret index clamp speed
The max. speed during indexing is set. This becomes the max. speed of the motor when set to "0".
0 to 32767 (r/min)

No. Items Details Setting
SP113 WINP Turret index in-position width
The position error range is set in which an orientation (indexing) completed signal is output during turret indexing. This becomes the same as SP004 (OINP) when set to "0".
3314 SP114 OPER Orientation pulse miss check value
An alarm "5C" will occur if the pulse miss value in the orientation stop exceed this setting value. (Note that this is invalid when set to "0".) In this parameter, set the value to fulfill the following conditions. SP114 setting value > 1.5 × SP004 (orientation in-position width)
3315 SP115 OSP2 Orientation changeover speed limit value 2
When the door interlock spindle speed clamp signal is ON, this setting is used instead of OSP(SP005), CZRN(SP149) and TZRN(SP214). (Note that SP149 and SP214 are used only for the M65V.)
0 to 32767 (r/min)
Set by Mitsubishi. Set "0" unless designated in particular.
3318 SP118 ORCT Number of orientation retry times
Set the number of times to retry when an orientation or feedback error occurs. The warning (A9) is issued while retrying orientation, and an alarm (5C) is issued when the set number of times is exceeded.
0 to 100 (time)
Not used. Set to “0”. 0 0

No. Items Details Setting
Set the spindle synchronous specifications in bit units.
0000 to FFFF HEX setting
F E D C B A 9 8 odx8
7 6 5 4 3 2 1 0 fdir pyfx fclx
(Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1 0 fclx Closed loop Semi-closed loop 1 2
3 pyfx Normal excitation Position loop excitation fixed (strong) 4
5 fdir Position detector polarity (+)
Position detector polarity (–) 6 7 8 9 A B C
Magnification of excessive error width × 8 times valid E F
odx8 Magnification of excessive error width × 8 times invalid
SP178 VGSP Spindle synchronous speed loop gain propor- tional term
Set the speed loop proportional gain in spindle synchronization mode.
0 to 1000 (1/s)
SP179 VGSI Spindle synchronous speed loop gain integral term
Set the speed loop integral gain in spindle synchronization mode.
0 to 1000 (0.1 1/s)
SP180 VGSD Spindle synchronous speed loop gain delay advance term
Set the speed loop delay advance gain in spindle synchronization mode. When this parameter is set to "0", PI control is exercised.
0 to 1000 (0.1 1/s)
SP181 VCGS Target value of variable speed loop proportional gain at spindle synchroniza-ti on
Set the magnification of speed loop proportional gain with respect to SP178 (VGSP) at the maximum speed defined in SP017 (TSP) at spindle synchronization.

No. Items Details Setting
SP182 VCSS Change starting speed of variable speed loop proportional gain at spindle synchroniza-ti on
Set the speed for starting change of speed loop proportional gain at spindle synchronization.
0 to 32767 (r/min)
SP178× (SP181/100)
SP182 SP017
3383 SP183 SYNV Sync match- ing speed at spindle syn- chronization
For changeover from the speed loop to the position loop at spindle synchronization, set a speed command error range for output of the sync speed matching signal.
0 to 1000 (r/min)
SP184 FFCS Acceleration rate feed forward gain at spindle synchronizati on
Set the acceleration rate feed forward gain at spindle synchronization. This parameter is used only with the SPJ2.
3385 SP185 SINP Spindle sync in-position width
Set the position error range for output of the in-position signal at spindle synchronization.
SP186 SODR Excessive error width at spindle synchronizati on
Set the excessive error width at spindle synchronization.
1 to 32767 (1/4 pulse) (1 pulse =0.088°)
SP187 IQGS Current loop gain magnifi- cation1 at spindle syn- chronization
Set the magnification of current loop gain (torque component) at spindle synchronization.
SP188 IDGS Current loop gain magnifi- cation 2 at spindle syn- chronization
Set the magnification of current loop gain (excitation component) at spindle synchronization.
Not used. Set to "0". 0 0

No. Items Details Setting
Set the synchronous tapping specifications in bit units.
0000 to FFFF HEX setting
F E D C B A 9 8 zrtn ptyp od8x
7 6 5 4 3 2 1 0 fdir cdir pyfx fclx
(Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1 0 fclx Closed loop Semi-closed loop 1 2
3 pyfx Normal excitation Position loop excitation fixed (strong) 4 cdir Command polarity (+) Command polarity (–)
5 fdir Position detector polarity (+)
Position detector polarity (–) 6 7 8 9 A B C
od8x Magnification of excessive error width × 8 times invalid
Magnification of excessive error width × 8 times valid
F zrtn Zero point return direction: CCW
Set the speed loop proportional gain in synchronous tapping mode.
0 to 1000 (1/s)
tapping speed loop gain propor- tional term
Set the speed loop integral gain in synchronous tapping mode.
tapping speed loop gain integral term
(0.1 1/s)
Set the speed loop delay advance gain in synchronous tapping mode. When this parameter is set to "0", PI control is exercised.
tapping speed loop gain delay advance term
(0.1 1/s)
SP197 Not used. Set to "0". 0 0
SP198 VCGT Target value of
Set the magnification of speed loop proportional gain with respect to SP194 (VGTP) at the maximum motor speed defined in SP017 (TSP) at synchronous tapping.
variable speed loop proportional gain at synchronous tapping

No. Items Details Setting
SP199 VCST Change starting
Set the speed for starting change of speed loop proportional gain at synchronous tapping.
0 to 32767 (r/min)
speed of variable speed loop proportional gain at synchronous tapping
SP199 SP017
Set the acceleration feed-forward gain for selection of gear 000 at synchronous tapping. This parameter should be used when an error of relative position to Z-axis servo is large.
tapping acceleration feed forward gain (gear 1)
Set the acceleration feed-forward gain for selection of gear 001 at synchronous tapping.
tapping acceleration feed forward gain (gear 2)
Set the acceleration feed-forward gain for selection of gear 010 at synchronous tapping.
tapping acceleration feed forward gain (gear 3)
Set the acceleration feed-forward gain for selection of gear 011 at synchronous tapping.
tapping acceleration feed forward gain (gear 4)
Not used. Set to "0". 0 0
3414 SP214 TZRN Synchronous tapping zero point return speed
This parameter is valid when SP193 (SPECT) bitE is set to "0". Set the zero point return speed used when the speed loop changes to the position loop.
0 to 500 (r/min)
3415 SP215 TPDT Synchronous tapping zero point return deceleration rate
This parameter is valid when SP193 (SPECT) bitE is set to "0". Set the deceleration rate where the machine starts to decelerate when it returns to the target stop point during synchronous tapping zero point return. When the machine tends to overshoot at the stop point set a smaller value.
1 to 10000 (pulse)
3416 SP216 TPST Synchronous tapping zero point return shift amount
This parameter is valid when SP193 (SPECT) bitE is set to "0". Set the synchronous tapping zero point position.


Set the position error range in which in-position signal is output during synchronize tapping.
SP219 IQGT Current loop gain magnifi- cation 1 at synchronous tapping
Set the magnification of current loop gain (torque component) during synchronous tapping.
SP220 IDGT Current loop gain magnifi- cation 2 at synchronous tapping
Set the magnification of current loop gain (excitation component) during synchronous tapping.
Set by Mitsubishi. Set "0" unless designated in particular.
Set the ratio of the motor inertia + load inertia and motor inertia. Setting
(Normally, set "100" or more. When less than "50" is set, the setting will be invalid.)

No. Items Details Setting
SP234 OBS1 Disturbanc e observer low path filter frequency
Set the frequency of the low path filter for when the disturbance observer is valid.
0 to 1000 (1/s)
Setting (1/s) = 2πf
f: Approx. 1.5 times the disturbance
SP235 OBS2 Disturbanc e observer gain
Set the gain for the disturbance observer. 0 to 500 (%)
Not used. Set to "0". 0 0
DA1NO D/A output channel 1 data number
Set the output data number for channel 1 of the D/A output function. When the setting value is "0", the output is speedometer. Refer to "8.5.1 D/A OUTPUT SPESIFICATIONS".
3454 SP254 DA2NO D/A output channel 2 data number
Set the output data number for channel 2 of the D/A output function. When the setting value is "0", the output is load meter. Refer to "8.5.1 D/A OUTPUT SPESIFICATIONS ".
3455 SP255 DA1MPY DA output channel 1 magnifica- tion
Set the data magnification for channel 1 of the D/A output function. The output magnification is (setting value)/256. When set to "0", the output magnification becomes 1-fold, in the same manner as when "256" is set. Refer to "8.5.1 D/A OUTPUT SPESIFICATIONS ".
–32768 to 32767 (1/256-fold)
3456 SP256 DA2MPY DA output channel 2 magnifica- tion
Set the data magnification for channel 2 of the D/A output function. The output magnification is (setting value)/256. When set to "0", the output magnification becomes 1-fold, in the same manner as when "256" is set. Refer to "8.5.1 D/A OUTPUT SPESIFICATIONS ".
–32768 to 32767 (1/256-fold)

No. Items Details Setting
RPM BSD
Motor constant (H coil)
This parameter is valid only in the following two conditional cases: (a) In case that SP034 (SFNC2) bit0=1
0000 to FFFF HEX setting
and SP034 (SFNC2) bit2=0 Set the motor constants when using a special motor, not described in the SP040 (MTYP) explanation and when not using the coil changeover motor. (b) In case that SP034 (SFNC2) bit0=1
and SP034 (SFNC2) bit2=1 Set the motor constant of the H coil of the coil changeover motor. (Note) It is not allowed for the user to
change the setting.
RPML BSDL
Motor constant (L coil)
This parameter is valid only in the following conditional case: (a) In case that SP034 (SFNC2) bit0=1
0000 to FFFF HEX setting
and SP034 (SFNC2) bit2=1 Set the motor constant of the L coil of the coil changeover motor. (Note) It is not allowed for the user to
change the setting.

8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH The spindle parameter setting and display method will differ according to the NC being used, so refer to Instruction Manual for each NC and the following spindles.
MELDAS AC Servo and Spindle MDS-A Series MDS-B Series Specifications Manual .BNP-B3759 MELDAS AC Servo and Spindle MDS-C1 Series Specifications Manual BNP-C3000
For parameters marked with a (PR) in the tables, turn the NC power OFF after setting. The parameters will be valid after the power is turned ON again. The "fixed control constants" and "fixed control bits" in this section are set by Mitsubishi.
! Do not make remarkable adjustments or changes of the parameters as the operation may
become unstable.
! In the explanation on bits, set all bits not used, including blank bits, to “0”.
No. Items Details Setting
3201 SP001 PGM Magnetic sensor and motor built-in encoder orientation position loop gain
As the set value is larger, the orientation time becomes shorter and servo rigidity is increased. However, vibration is increased and the machine becomes likely to overshoot.
0 to 1000 (0.1 1/s)
3202 SP002 PGE Encoder orientation position loop gain
As the set value is larger, the orientation time becomes shorter and servo rigidity is increased. However, vibration is increased and the machine becomes likely to overshoot.
0 to 1000 (0.1 1/s)
3203 SP003 PGC0 C-axis non-cutting position loop gain
Set the position loop gain in C-axis non-cutting mode. During non-cutting (rapid traverse, etc.) with the C axis control, this position loop gain setting is valid.
1 to 100 (1/s)
3204 SP004 OINP Orientation in-position width
Set the position error range in which an orientation completion signal is output.
SP005 OSP Orientation mode changing speed limit value
Set the motor speed limit value to be used when the speed loop is changed to the position loop in orientation mode. When this parameter is set to "0", SP017 (TSP) becomes the limit value.
0 to 32767 (r/min)
3206 SP006 CSP Orientation mode deceleration rate
As the set value is larger, the orientation time becomes shorter. However, the machine becomes likely to overshoot.
Standard · range · setting

No. Items Details Setting
3207 SP007 OPST In-position shift amount for orientation
Set the stop position for orientation. (i)Motor built-in encoder, encoder:
(i) 0 to 4095
Set the value by dividing 360° by 4096. (ii)Magnetic sensor:
Divide –5° to +5° by 1024 and put 0° for 0.
SP008 Not used. Set to "0". 0 0
3209 SP009 PGT Synchroni- zed tapping Position loop gain
Set the spindle position loop gain in synchronized tapping mode.
1 to 100 (1/s)
3210 SP010 PGS Spindle synchro- nous position loop gain
Set the spindle position loop gain in spindle synchronization mode.
1 to 100 (1/s)
Use not possible. 0 0
SP017 TSP Maximum motor speed
Set the maximum motor speed of the spindle. 1 to 32767 (r/min)
SP018 ZSP Motor zero speed
Set the motor speed for which zero-speed output is performed.
1 to 1000 (r/min)
SP019 CSN1 Speed cushion 1
Set the time constant for a speed command from "0" to the maximum speed. (This parameter is invalid in position loop mode.)
1 to 32767 (10ms)
SP020 SDTS Speed detection set value
Set the motor speed so for which speed detection output is performed. Usually, the setting value is 10% of SP017 (TSP).
0 to 32767 (r/min)
3221 SP021 TLM1 Torque limit 1
Set the torque limit rate for torque limit signal 001. 0 to 120 (%) 10
Set the speed loop proportional gain in speed control mode. When the gain is increased, response is improved but vibration and sound become larger.
0 to 1000 (1/s)
loop gain propor- tional term under speed control
Set the speed loop integral gain in speed control mode. Usually, set a value in proportion to SP022 (VGNP1).
0 to 1000 (0.1 1/s)
loop gain integral term under speed control

No. Items Details Setting
SP024 Use not possible. 0 0
SP025 GRA1 Spindle gear teeth count 1
Set the number of gear teeth of the spindle corresponding to gear 000.
SP026 GRA2 Spindle gear teeth count 2
Set the number of gear teeth of the spindle corresponding to gear 001.
SP027 GRA3 Spindle gear teeth count 3
Set the number of gear teeth of the spindle corresponding to gear 010.
SP028 GRA4 Spindle gear teeth count 4
Set the number of gear teeth of the spindle corresponding to gear 011.
SP029 GRB1 Motor shaft gear teeth count 1
Set the number of gear teeth of the motor shaft corresponding to gear 000.
SP030 GRB2 Motor shaft gear teeth count 2
Set the number of gear teeth of the motor shaft corresponding to gear 001.
SP031 GRB3 Motor shaft gear teeth count 3
Set the number of gear teeth of the motor shaft corresponding to gear 010.
SP032 GRB4 Motor shaft gear teeth count 4
Set the number of gear teeth of the motor shaft corresponding to gear 011.
Standard · range · setting

No. Items Details Setting
Set the spindle function 1 in bit units.
0000 to FFFF HEX setting
F E D C B A 9 8 poff hzs ront pycal pychg
7 6 5 4 3 2 1 0 pyst pyoff sftk dflt 1a2m (Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0 1a2m 1 amplifier 2 motor function: Invalid 1 amplifier 2 motor function: Valid 1 dflt Default motor: Main Default motor: Sub 2 sftk SF-TK card invalid SF-TK card valid 3 4 5 6 pyoff 7 pyst 8 pychg
This is used by Mitsubishi. Set to "0" unless particularly designated.
9 pycal (Conventional specifications)
High-speed rate deceleration method valid for minimum excitation rate A
B This is used by Mitsubishi. Set to "0" unless particularly designated. C ront Normal ready ON High-speed ready ON
D This is used by Mitsubishi. Set to "0" unless particularly designated.
E hzs Gate OFF by high-cycle zero speed invalid
Gate OFF by high-cycle zero speed valid
F poff Contactor hold at NC power OFF invalid
Contactor hold at NC power OFF valid
(Note) When SPH is used, bit 0 and bit 1 will be invalid.

No. Items Details Setting
Set the spindle function 2 in bit units.
0000 to FFFF HEX setting
7 6 5 4 3 2 1 0 mkc2 mkch invm mts1 (Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0 mts1 Special motor constant invalid
Special motor constant setting valid
1 invm A general-purpose motor FV control invalid
A general-purpose motor FV control valid
2 mkch Coil switch function invalid Coil switch function valid
3 mkc2 Coil switch specification 2 invalid Coil switch specification 2 valid (Note1) (Note2) 4 5 6 7 8 9 A B C D E F
(Note1) To validate bit3(mkc2), NC side needs to prepare. (Note2) Always turn the bit2 at the same time to use bit3.
Set the spindle function 3 in bit units.
0000 to FFFF HEX setting
7 6 5 4 3 2 1 0 lbsd hbsd lwid hwid (Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0 hwid H-coil wide-range constant output invalid
H-coil wide-range constant output valid
L-coil wide-range constant output valid 2 hbsd H-coil base slide invalid H-coil base slide valid 3 lbsd L-coil base slide invalid L-coil base slide valid 4 5 6 7 8 9 A B C D E F
1 lwid L-coil wide-range constant output invalid
(Used with SPJ.)

No. Items Details Setting
Set the spindle function 4 in bit units.
0000 to FFFF HEX setting
F E D C B A 9 8 dslm dssm
7 6 5 4 3 2 1 0 enc2 enc1 mag2 mag1 plg2 plg1 (Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1 0 plg1 PLG of motor 1 valid PLG of motor 1 invalid 1 plg2 PLG of motor 2 valid PLG of motor 2 invalid 2 mag1 MAG of motor 1 valid MAG of motor 1 invalid 3 mag2 MAG of motor 2 valid MAG of motor 2 invalid 4 enc1 ENC of motor 1 valid ENC of motor 1 invalid 5 enc2 ENC of motor 2 valid ENC of motor 2 invalid 6 7
8 dssm Speedometer output valid
9 dslm Load meter output valid Load meter output invalid A B C D E F
Set the spindle function 5 in bit units.
0000 to FFFF HEX setting
F E D C B A 9 8 splg dplg noplg nsno nosg
7 6 5 4 3 2 1 0 plgo mago enco (Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0 enco Encoder orientation invalid
1 mago Magnetic sensor orientation invalid
Magnetic sensor orientation valid 2 plgo PLG orientation invalid PLG orientation valid 3 4 5 6 7
8 nosg No-signal detection type (Always monitoring)
Monitoring only in position loop or orientation-mode
9 nsno No-signal detection valid
Constant monitor of PLG-Z phase no-signal valid B C D E dplg F splg
Constant monitor of PLG-Z phase no-signal invalid
This is used by Mitsubishi. Set to "0" unless particularly designated.
(Note) For bit0 to 2, do not set two bits or more to
"1" at the same time.

No. Items Details Setting
Set the spindle function 6 in bit units.
0000 to FFFF HEX setting
F E D C B A 9 8 oplp lmx iqsv XFzs dcsn lmnp pl80 sdt2
7 6 5 4 3 2 1 0 vfbs orm adin tdn plg2 pftm alty
(Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0 alty Deceleration stop during special alarm invalid
Deceleration stop during special alarm valid 1
2 pftm Encoder feedback serial communication invalid
Encoder feedback serial communication valid
3 plg2 Semi-closed pulse output signal×2 invalid
Semi-closed pulse output signal×2 valid 4
5 adin Interpolation during thread cutting invalid
Interpolation during thread cutting valid
6 orm Orientation start memo invalid
Orientation start memo valid
7 vfbs This is used by Mitsubishi. Set to "0" unless particularly designated.
8 sdt2 (Follows SFNC6-bitC setting)
Set output 2 to 2nd speed detection output
9 pl80 MHE90K detector's 180 wave PLG
180 wave PLG other than MHE90K
A lmnp This is used by Mitsubishi. Set to "0" unless particularly designated.
dcsn Dual cushion during acceleration/ deceleration valid
Dual cushion during acceleration/ deceleration invalid
C XFzs Set output 2 to MP scale low (L) speed mode
Set output 2 to zero speed output D iqsv E lmx
This is used by Mitsubishi. Set to "0" unless particularly designated
F oplp Open loop operation invalid
Open loop operation valid
bit Name Meaning when set to 0 Meaning when set to 1
0 alty Deceleration stop during special alarm invalid
Deceleration stop during special alarm valid 1
2 pftm Encoder feedback serial communication invalid
Encoder feedback serial communication valid
3 plg2 Semi-closed pulse output signal×2 invalid
Semi-closed pulse output signal×2 valid 4 tdn 5 adin Fixed control bit
6 orm Orientation start memo invalid
Orientation start memo valid 7 vfbs 8 sdt2 9 pl80 A lmnp B dcsn C XFzs D iqsv E lmx
F oplp Open loop operation invalid
Open loop operation valid


Set the amplifier type. Set each amplifier type or "0"

No. Items Details Setting
SP040 MTYP Motor type This parameter is valid when SP034 (SFNC2) bit0 is set to "0". Set the appropriate motor number from the standard motors listed below.
0000 to FFFF HEX setting
setting Motor type Maximum
nding amplifier 0000 0001 SJ-2.2A 10000 r/min SP-22 0002 SJ-3.7A 10000 r/min SP-37 0003 SJ-5.5A 8000 r/min SP-55 0004 SJ-7.5A 8000 r/min SP-75 0005 SJ-11A 6000 r/min SP-110 0006 SJ-15A 6000 r/min SP-150 0007 SJ-18.5A 6000 r/min SP-185 0008 SJ-22A 4500 r/min SP-220 0009 SJ-26A 4500 r/min SP-260 000A SJ-30A 4500 r/min SP-300 000B 000C 000D 000E 000F 0010 0011 SJ-N0.75A 10000 r/min SP-075 0012 SJ-N1.5A 10000 r/min SP-15 0013 SJ-N2.2A 10000 r/min SP-22 0014 SJ-N3.7A 10000 r/min SP-37 0015 SJ-N5.5A 8000 r/min SP-55 0016 SJ-N7.5A 8000 r/min SP-75 0017 0018 0019 001A 001B SJ-J2.2A 10000 r/min SP-22 001C SJ-J3.7A 10000 r/min SP-37 001D SJ-J5.5A 8000 r/min SP-55 001E SJ-J7.5A 8000 r/min SP-75 001F


F E D C B A 9 8 amp rtyp
7 6 5 4 3 2 1 0 ptyp bit Explanation 0 1
When the CN4 connector of the drive unit and the power supply are connected, setting below is necessary. To validate the external emergency stop function, add 40h.
3 Set- ting 0x 1x 2x 3x 4x 5x 6x 7x 8x
8 Set the regenerative resistor type when MDS-A-CR is used.
A 0 MDS-C1-CV (Setting when using power supply regeneration)
This parameter is used to set the C-axis detector range. Set "0" for this parameter. "2" is used by Mitsubishi for testing.

No. Items Details Setting
SP043 TRNG Synchro- nous tapping, spindle synchro- nous detector range
This parameter is used to set the synchronous tapping or spindle synchronous detector range. Set "0" for this parameter.
SP044 TRANS NC communi- cation frequency
Set a frequency of data communication with NC.
3245 SP045 CSNT Dual cushion timer
Set the cycle to add the increment values in the dual cushion process. When this setting value is increased, the dual cushion will increase, and the changes in the speed during acceleration/deceleration will become gradual.
0 to 1000 (ms)
SP046 CSN2 Speed command dual cushion
For an acceleration/deceleration time constant defined in SP019 (CSN1) , this parameter is used to provide smooth movement only at the start of acceleration/deceleration. As the value of this parameter is smaller, it moves smoother but the acceleration/deceleration time becomes longer. To make this parameter invalid, set "0".
SP047 SDTR Speed detection reset value
Set the reset hysteresis width for a speed detection set value defined in SP020 (SDTS).
0 to 1000 (r/min)
SP047 SDTR Speed detection reset value
Set the reset hysteresis width for a speed detection set value defined in SP020 (SDTS).
0 to 1000 (r/min)
SP048 SUT Speed reach range
Set the speed deviation rate with respect to the commanded speed for output of the speed reach signal.
3249 SP049 TLM2 Torque limit 2
Set the torque limit rate for the torque limit signal 010.
3250 SP050 TLM3 Torque limit 3
Set the torque limit rate for the torque limit signal 011.
3251 SP051 TLM4 Torque limit 4
Set the torque limit rate for the torque limit signal 100.
3252 SP052 TLM5 Torque limit 5
Set the torque limit rate for the torque limit signal 101.
3253 SP053 TLM6 Torque limit 6
Set the torque limit rate for the torque limit signal 110.
3254 SP054 TLM7 Torque limit 7
Set the torque limit rate for the torque limit signal 111.
Standard · range · setting

No. Items Details Setting
SP055 SETM Excessive speed deviation timer
Set the timer value until the excessive speed deviation alarm is output. The value of this parameter should be longer than the acceleration/deceleration time.
0 to 60 (s) 12
3256 SP056 PYVR Variable excitation (min value)
Set the minimum value of the variable excitation rate. Select a smaller value when gear noise is too high. However, a larger value is effective for impact response.
SP057 STOD Constant → excessive judgment value
Set the value for judging when changing from a constant to excessive speed command.
0 to 50 (r/min)
SP058 SDT2 Fixed control constant
Set by Mitsubishi. Set "0" unless designated in particular.
SP059 MKT Winding changeover base shut-off timer
Set the base shut-off time for contactor switching at winding changeover. Note that the contactor may be damaged with burning if the value of this parameter is too small.
50 to 10000 (ms)
SP060 MKT2 Current limit timer after winding changeover
Set the current limit time to be taken after completion of contactor switching at winding changeover.
0 to 10000 (ms)
SP061 MKIL Current limit value after winding changeover
Set the current limit value during a period defined in SP060 (MKT2) after completion of contactor switching at winding changeover.
SP062 Not used. Set to "0". 0 0
Standard · range · setting


Set the time constant for detection of the motor overload alarm.
Set the detection level of the motor overload alarm.
Set the magnification of speed loop proportional gain with respect to SP022 (VGNP1) at the maximum motor speed defined in SP017 (TSP).
Set the speed when the speed loop proportional gain change starts.
Set the speed where the current loop gain change starts.
Set the speed where the current loop gain change ends.
SP069 VIGN Target value of variable current loop gain
Set the magnification of current loop gain (torque component and excitation component) for a change ending speed defined in SP068 (VIGWB). When this parameter is set to "0", the magnification is 1.
0 to 6000 6001 to 8000 5000 8000 45 8001 or more 5000 10000 64

No. Items Details Setting
3270 SP070 FHz Machine resonance suppressio n filter frequency
When machine vibration occurs in speed and position control, set the frequency of the required vibration suppression. Note that a value of 100Hz or more is set. Set to "0" when not used.
0 to 3000 (Hz)
Set by Mitsubishi. Set "0" unless designated in particular.
SP073 VR2GN
SP074 IGDEC
3275 SP075 R2KWS
F E D C B A 9 8 r2ini 7 6 5 4 3 2 1 0 r2am r2lm r2dn no51 r2ch bit Name Meaning when set to 0 Meaning when set to 1 0 r2ch 1 no51 2 r2dm 3 r2lm 4 r2am
This is used by Mitsubishi. Set to "0" unless particularly designated.
5 6 7 8 r2ini This is used by Mitsubishi. Set to "0" unless particularly designated 9 A B C D E F
3276 SP076 FONS Machine resonance suppressio n filter operation speed
When the vibration increases in motor stop (ex. in orientation stop) when the machine vibration suppression filter is operated by SP070, operate the machine vibration suppression filter at a speed of this parameter or more. When set to "0", this is validated for all speeds.
0 to 32767 (r/min)
SP077 TDSL Fixed control constant
Set by Mitsubishi. Set "14" unless designated in particular.
Set by Mitsubishi. Set "0" unless designated in particular.

No. Items Details Setting
SP080 Use not possible. 0 0
This is used by Mitsubishi. Set to "0" unless particularly designated.
SP083
SP084
Use not possible. 0 0
SP087 DIQM Target value of
Set the minimum value of variable torque limit at deceleration.
variable torque limit magnifica- tion at deceleration
SP088 DIQN Speed for starting change of variable torque limit magnifica- tion at deceleration
Set the speed where the torque limit value at deceleration starts to change.
0 to 32767 (r/min)
Inversely proportional to speed
SP088 SP017
SP089 Use not possible. 0 0
SP090 Use not possible. 0 0
3291 SP091 OFSN Motor PLG forward rotation offset compensa- tion
Set the PLG offset value for the forward rotation. Normally set to "0".
–2048 to 2047 (–1mv)
3292 SP092 OFSI Motor PLG reverse rotation offset compensa- tion
Set the PLG offset value for the reverse rotation. Normally set to "0".
–2048 to 2047 (–1mv)
SP093 ORE Tolerable pulse check error
Set this when detecting the pulse detector's pulse mistakes. (Valid only for full close control.)
SP094 LMAV Load meter
Set the filter time constant of load meter output. When "0" is set, a filter time constant is set to 100ms.
0 to 32767 (2ms)
SP095 VFAV Fixed control
Set by Mitsubishi. Set "0" unless designated in particular.

No. Items Details Setting
SP096 EGAR Encoder gear ratio
Set the gear ratio between the spindle end and the encoder end (except for the motor-built-in encoder) as indicated below.
0 1 : 1 1 1 : 1/2 2 1 : 1/4 3 1 : 1/8 4 1 : 1/16
Set the orientation specifications in bit units.
0000 to FFFF HEX setting
F E D C B A 9 8 ostp orze ksft gchg ips2 zdir
7 6 5 4 3 2 1 0 vg8x mdir fdir osc1 pyfx dmin odi2 odi1
(Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1 0 odi1
Orientation rotation direction 00: Previous (the direction in which the motor has so far rotated under speed control) 01: Forward rotation 10: Backward rotation 11: Prohibited (Same as setting value = 10)
2 dmin Orientation in-position advance invalid
Orientation in-position advance valid
3 pyfx Excitation min. (50%) during orientation servo lock invalid
Excitation min. (50%) during orientation servo lock valid
4 osc1 Indexing speed clamp invalid
Indexing speed clamp valid
7 vg8x Speed gain *1/8 during torque limit valid
Speed gain *1/8 during torque limit invalid 8
9 zdir This is used by Mitsubishi. Set to "0" unless particularly designated. A ips2 2nd in-position invalid 2nd in-position valid B
C gchg Gain changeover during orientation invalid
Gain changeover during orientation valid
D ksft Orientation virtual target shift invalid
Orientation virtual target shift valid E orze F ostp
This is used by Mitsubishi. Set to "0" unless particularly designated.
In-position advance (bit 2)
0 (invalid) 1 (valid)
In-position signal in OINP width=1 Control output 4/ bit 4=1 Second in-position signal=0 Control output 4/ bit F=1
In-position signal in OINP width=1 Control output 4/ bit 4=1 Second in-position signal=0 Control output 4/ bit F=0
In-position signal in DINP width=1 Control output 4/ bit 4=1 Second in-position signal in OINP width = 0 Control output 4/ bit F=1

No. Items Details Setting
SP098 VGOP Speed loop gain propor- tional term in orientation mode
Set the speed loop proportional gain in orientation mode. When the gain is increased, rigidity is improved in the orientation stop but vibration and sound become larger.
0 to 1000 (1/s)
SP099 VGOI Orientation mode speed loop gain integral term
Set the speed loop integral gain in orientation mode.
0 to 1000 (0.1 1/s)
SP100 VGOD Orientation mode speed loop gain delay advance term
Set a loop gain delay advance gain in orientation mode. When this parameter is set to "0", PI control is applied.
0 to 1000 (0.1 1/s)
SP101 DINP Orientation advance in-position width
When using the orientation in-position advance function, set the in-position width that is larger than the normal in-position width defined in SP004 (OINP).
SP102 OODR Excessive error value in orientation mode
Set the excessive error width in orientation mode.
0 to 32767 (1/4 pulse) (1 pulse= 0.088°)
SP103 FTM Index positioning completion OFF time timer
Set the time for forcedly turn OFF the index positioning completion signal (different from the orientation completion signal) after the leading edge of the indexing start signal.
0 to 10000 (ms)
SP104 TLOR Torque limit value for orientation servo locking
Set the torque limit value for orientation in-position output. If the external torque limit signal is input, the torque limit value set by this parameter is made invalid.
SP105 IQG0 Current loop gain magnifica- tion 1 in orientation mode
Set the magnification for current loop gain (torque component) at orientation completion.
SP106 IDG0 Current loop gain magnifica- tion 2 in orientation mode
Set the magnification for current loop gain (excitation component) at orientation completion.
3307 SP107 CSP2 Deceleration rate 2 in orientation mode
Set the deceleration rate in orientation mode corresponding to the gear 001. When this parameter is set to "0", same as SP006 (CSP).
Standard · range · setting

No. Items Details Setting
3308 SP108 CSP3 Deceleration rate 3 in orientation mode
Set the deceleration rate in orientation mode corresponding to the gear 010. When this parameter is set to "0", same as SP006 (CSP).
3309 SP109 CSP4 Deceleration rate 4 in orientation mode
Set the deceleration rate in orientation mode corresponding to the gear 011. When this parameter is set to "0", same as SP006 (CSP).
Use not possible. 0
3314 SP114 OPER Orientation pulse miss check value
An alarm "5C" will occur if the pulse miss value at the orientation stop exceeds this setting value. (Note that this is invalid when set to "0".) In this parameter, set the value to fulfill the following conditions. SP114 setting value > 1.5 × SP004 (orientation in-position width)
3315 SP115 OSP2 Orientation motor speed clamp value 2
When the orientation clamp speed is changed by the control input, this parameter setting will be used instead of SP005: OSP. Indexing speed clamp valid This parameter is used when (SP097: SPEC0-bit4 = 1).
0 to 32767 (r/min)
3316 SP116 OPYVR Minimum excitation value after changeover (2nd minimum excitation rate)
Minimum excitation rate when position control input or external input is selected.
3317 SP117 ORUT This is used by Mitsubishi. Set to "0" unless particularly designated.
3318 SP118 ORCT Number of orientation retry times
Set the number of times to retry when an orientation or feedback error occurs. The warning (A9) is issued while retrying orientation, and an alarm (5C) is issued when the set number of times is exceeded.
0 to 100 (time)
3319 SP119 MPGH Orientation position gain H winding compensa- tion magnifi- cation
Set the compensation magnification of the orientation position loop gain for the H winding. H winding orientation position loop gain = SP001 (or SP002) × SP119/256 When set to "0", will become the same as SP001 or SP002.
0 to 2560 (1/256-fold)

No. Items Details Setting
3320 SP120 MPGL Orientation position gain L winding compensa- tion magnifi- cation
Set the compensation magnification of the orientation position loop gain for the L winding. L winding orientation position loop gain = SP001 (or SP002) × SP120/256 When set to "0", will become the same as SP001 or SP002.
0 to 2560 (1/256-fold)
3321 SP121 MPCSH Orientation deceleration rate H winding compensa- tion magnifi- cation
Set the compensation magnification of the orientation deceleration rate for the H winding. Orientation deceleration rate for the H winding = SP006 × SP121/256 When set to "0", will become the same as SP006.
0 to 2560 (1/256-fold)
3322 SP122 MPCSL Orientation deceleration rate L winding compensa- tion magnifi- cation
Set the compensation magnification of the orientation deceleration rate for the L winding. Orientation deceleration rate for the L winding = SP006 × SP122/256 When set to "0", will become the same as SP006.
0 to 2560 (1/256-fold)
3323 SP123 MGD0 Magnetic sensor output peak value
This parameter is used for adjustment of orientation operation of the magnetic sensor. Set the output peak value of the magnetic sensor. If a gap between the sensor and the magnetizing element is small, increase the value of this parameter. If it is large, decrease the value of this parameter.
1 to 10000 Standard magnetizin g element: 542 Small magnetizin g element: 500
3324 SP124 MGD1 Magnetic sensor linear zone width
This parameter is used for adjustment of orientation operation of the magnetic sensor. Set the linear zone width of the magnetic sensor. If the radius of the mounted magnetizing element is large, decrease the value of this parameter. If it is small, increase the value of this parameter.
1 to 10000 Standard magnetizin g element: 768 Small magnetizin g element: 440
Standard · range · setting

No. Items Details Setting
3325 SP125 MGD2 Magnetic sensor switching point
This parameter is used for adjustment of orientation operation of the magnetic sensor. Set the distance dimension from the target stop point at switching from position feedback to magnetic sensor output. Normally, set a value that is approx. 1/2 of the value defined in SP124.
1 to 10000 Standard magnetizin g element: 384 Small magnetizin g element: 220
Use not possible. 0 0
Set the C-axis specifications in bit units.
F E D C B A 9 8 zrtn ptyp fb9x zrtd zrn2 zdir ztyp
7 6 5 4 3 2 1 0 vg8x fdir phos rtrn adin fclx
(Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
0 fclx Closed loop Semi-closed loop (Gear 1 : 1 only)
1 adin Interpolation A/D compensation invalid
Interpolation A/D compensation valid
2 rtrn Position monitor during ready OFF invalid
Position monitor during ready OFF valid
3 phos Normal (no compensation)
Vx4 synchronization compensation valid 4
5 fdir Position detector polarity (+)
Position detector polarity (–) 6
7 vg8x Speed gain × 1/8 during torque limit valid
Speed gain × 1/8 during torque limit invalid
9 zdir Z-phase rising polarity (+) Z-phase rising polarity (–)
A B zrn2 C zrtd
This is used by Mitsubishi. Set to "0" unless particularly designated.
D fb9x Speed feedback Standard (PLG)
Speed feedback 90,000 pulse detector
F zrtn Zero point return direction: CCW
3330 SP130 PGC1 First position loop gain for cutting on C-axis
Set the position loop gain when the first gain is selected for C axis cutting.
1 to 100 (1/s)
3331 SP131 PGC2 Second position loop gain for cutting on C-axis
Set the position loop gain when the second gain is selected for C axis cutting.
1 to 100 (1/s)

No. Items Details Setting
3332 SP132 PGC3 Third position loop gain for cutting on C-axis
Set the position loop gain when the third gain is selected for C-axis cutting.
1 to 100 (1/s)
3333 SP133 PGC4 Stop position loop gain for cutting on C-axis
Set the position loop gain for stopping when carrying out C-axis cutting.
1 to 100 (1/s)
Set the speed loop proportional gain in C-axis non-cutting mode.
0 to 5000 (1/s)
non-cutting speed loop gain proportional item
SP135 VGCI0 C-axis non-cutting speed loop gain integral item
Set the speed loop integral gain in C-axis non-cutting mode.
0 to 5000 (0.1 1/s)
Set the speed loop delay advance gain in C-axis non-cutting mode. When this parameter is set to "0", PI control is exercised.
0 to 5000 (0.1 1/s)
non-cutting speed loop gain delay advance item
SP137 VGCP1 First speed
Set the speed loop proportional gain when the first gain is selected for C-axis cutting.
0 to 5000 (1/s)
loop gain proportional item for C-axis cutting
SP138 VGCI1 First speed loop gain integral item for cutting on C-axis
Set the speed loop integral gain when the first gain is selected for C-axis cutting.
0 to 5000 (0.1 1/s)
SP139 VGCD1 First speed
Set the speed loop delay advance gain when the first gain is selected for curing on the C-axis. When this parameter is set to "0", PI control is applied.
0 to 5000 (0.1 1/s)
loop gain delay advance item for cutting on C-axis
Set the speed loop proportional gain when the second gain is selected for C-axis cutting.
0 to 5000 (1/s)
speed loop gain proportional item for cutting on C-axis

No. Items Details Setting
SP141 VGCI2 Second speed loop gain integral item for cutting on C-axis
Set the speed loop integral gain when the second gain is selected for C-axis cutting.
0 to 5000 (0.1 1/s)
SP142 VGCD2 Second speed loop gain delay advance item for cutting on C-axis
Set the speed loop delay advance gain when the second gain is selected for C-axis cutting. When this parameter is set to "0", PI control is applied.
0 to 5000 (0.1 1/s)
SP143 VGCP3 Third speed loop gain proportional item for cutting on C-axis
Set the speed loop proportional gain when the third gain is selected for C-axis cutting.
0 to 5000 (1/s)
SP144 VGCI3 Third speed loop gain integral item for cutting on C-axis
Set the speed loop integral gain when the third gain is selected for C-axis cutting.
0 to 5000 (0.1 1/s)
SP145 VGCD3 Third speed loop gain delay advance item for cutting on C-axis
Set the speed loop delay advance gain when the third gain is selected for C-axis cutting. When this parameter is set to "0", PI control is applied.
0 to 5000 (0.1 1/s)
SP146 VGCP4 Speed loop gain propor- tional item for stop of cutting on C-axis
Set the speed loop proportional gain when C-axis cutting is stopped.
0 to 5000 (1/s)
SP147 VGCI4 Speed loop gain integral item for stop of cutting on C-axis
Set the speed loop integral gain when C-axis cutting is stopped.
0 to 5000 (0.1 1/s)
SP148 VGCD4 Speed loop gain delay advance item for stop of cutting on C-axis
Set the speed loop delay advance gain when C-axis cutting is stopped. When this parameter is set to "0", PI control is applied.
0 to 5000 (0.1 1/s)
Standard · range · setting

No. Items Details Setting
3349 SP149 CZRN C-axis zero point return speed
This parameter is valid when SP129 (SPECC) bitE is set to "0". Set the zero point return speed used when the speed loop changes to the position loop.
1 to 500 (r/min)
3350 SP150 CPDT C-axis zero point return deceleration point
This parameter is valid when SP129 (SPECC) bitE is set to "0". Set the deceleration rate where the machine starts to decelerate when it returns to the target stop point during C-axis zero point return. When the machine tends to overshoot at the stop point, set the smaller value.
3351 SP151 CPSTL C-axis zero point return shift amount (low byte)
This parameter is valid when SPECC (SP129) bitE is set to "0". Set the C-axis zero point position.
HEX setting 00000000 to FFFFFFFF (1/1000°)
3352 SP152 CPSTH C-axis zero point return shift amount (high byte)
Set the excessive error width on the C-axis. HEX setting
error width on C-axis (low byte)
00000000 to FFFFFFFF (1/1000°)
error width on C-axis (high byte)
3356 SP156 OVSH C-axis overshoot compensa- tion
Set this to prevent overshooting when shifting from movement to stopping with C-axis control. (Set this referring to the load meter display when overshooting occurred.)
Not used. Set to "0". 0 0
3359 SP159 CPY0 C-axis non-cutting variable excitation ratio
Set the minimum value of variable excitation ratio for non-cutting on the C-axis .
3360 SP160 CPY1 C-axis cutting variable excitation ratio
Set the minimum variable excitation ratio for cutting on the C-axis.

No. Items Details Setting
SP161 IQGC0 Current loop
Set the magnification of current loop gain (torque component) for C-axis non-cutting.
gain magnifi- cation 1 for non-cutting on C-axis
SP162 IDGC0 Current loop gain magnifi- cation 2 for non-cutting on C-axis
Set the magnification of current loop gain (excitation component) for C-axis non-cutting.
SP163 IQGC1 Current loop
Set the magnification of current loop gain (torque component) for C-axis cutting.
gain magnifi- cation 1 for cutting on C-axis
SP164 IDGC1 Current loop gain magnifi- cation 2 for cutting on C-axis
Set the magnification of current loop gain (excitation component) for C-axis cutting.
3365 SP165 PG2C C-axis position loop gain 2
Set the second position loop gain when high-gain control is carried out for control of the C-axis. This parameter is applied to all the operation modes of C-axis control. When this function is not used, assign "0".
0 to 999 (1/s)
3366 SP166 PG3C C-axis position loop gain 3
Set the third position loop gain when high-gain control is carried out for control of the C-axis. This parameter is applied to all the operation modes of C-axis control. When this function is not used, assign "0".
0 to 999 (1/s)
PGU Position loop gain for increased spindle holding force
Set the position loop gain for when the disturbance observer is valid.
0 to 100 (1/s)
VGUP Speed loop gain proportional item for increased spindle holding force
Set the speed loop gain proportional item for when the disturbance observer is valid.
0 to 5000 (1/s)
VGUI Speed loop gain integral item for increased spindle holding force
Set the speed loop gain integral item for when the disturbance observer is valid.
0 to 5000 (0.1 1/s)
Standard · range · setting


VGUD Speed loop gain delay advance item for increased spindle holding force
Set the speed loop gain delay advance item for when the disturbance observer is valid.
F E D C B A 9 8 Odx8 phos
7 6 5 4 3 2 1 0 fdir pyfx rtrn adin fclx
bit Name Meaning when set to 0 Meaning when set to 1 0 fclx Closed loop Semi-closed loop
3 pyfx Normal excitation Position loop excitation fixed (strong) 4
Position detector direc- tion (negative direction) 6 7 8 9 A B C
Magnification of excessive error width × 8 times valid E F (Used with SPJ)
odx8 Magnification of excessive error width × 8 times invalid
SP178 VGSP Spindle synchronous speed loop gain propor- tional term
Set the speed loop proportional gain in spindle synchronous mode.
SP179 VGSI Spindle synchronous speed loop gain integral term
Set the speed loop integral gain in spindle synchronous mode.

No. Items Details Setting
SP180 VGSD Spindle synchronous speed loop gain delay advance term
Set the speed loop delay advance gain in spindle synchronous mode. When this parameter is set to "0", PI control is applied.
0 to 1000 (0.1 1/s)
SP181 VCGS Spindle synchronous Target value of variable speed loop proportional gain
Set the magnification of speed loop proportional gain with respect to SP178 (VGSP) at the maximum speed defined in SP017 (TSP) in spindle synchronous mode.
SP182 VCSS Spindle synchronous Change starting speed of variable speed loop proportional gain
Set the speed when the speed loop proportional gain change starts in the spindle synchronous mode.
0 to 32767 (r/min)
SP178× (SP181/100)
SP182 SP017
3383 SP183 SYNV Spindle synchronous Sync match- ing speed
For changeover from the speed loop to the position loop in the spindle synchronous mode, set a speed command error range for output of the synchronous speed matching signal.
0 to 1000 (r/min)
SP184 FFCS Spindle synchronous Acceleration rate feed forward gain
Set the acceleration rate feed forward gain in the spindle synchronous mode. This parameter is used only with the SPJ2.
3385 SP185 SINP Spindle synchronous In-position width
Set the position error range for output of the in-position signal in the spindle synchronous mode.
SP186 SODR Spindle synchronous Excessive error width
Set the excessive error width in the spindle synchronous mode.
1 to 32767 ( pulse) (1 pulse =0.088°)
SP187 IQGS Spindle synchronous Current loop gain magnifi- cation1
Set the magnification of current loop gain (torque component) in the spindle synchronous mode.

No. Items Details Setting
SP188 IDGS Spindle synchronous Current loop gain magnifi- cation 2
Set the magnification of current loop gain (excitation component) in the spindle synchronous mode.
3389 SP189 PG2S Spindle synchronous Position loop gain 2
Set the second position loop gain when high-gain control is carried out in the spindle synchronous mode. When this parameter function is not used, set to "0".
0 to 999 (1/s)
3390 SP190 PG3S Spindle synchronous Position loop gain 3
Set the third position loop gain when high-gain control is carried out in the spindle synchronous mode. When this parameter function is not used, set to "0".
0 to 999 (1/s)
SP191 Use not possible. 0 0
SP192 Not used. Set to "0".
Set the synchronized tapping specifications in bit units.
0000 to FFFF HEX setting
F E D C B A 9 8 zrtn ptyp od8x phos
7 6 5 4 3 2 1 0 fdir cdir pyfx adin fclx
bit Name Meaning when set to 0 Meaning when set to 1
0 fclx Closed loop Semi-closed loop (Gear 1 : 1 only)
1 adin Interpolation A/D compensation invalid
Interpolation A/D compensation valid
2 rtrn Position monitor during ready OFF invalid
Position monitor during ready OFF valid
3 pyfx Normal excitation Position loop excitation fixed (strong) 4 cdir Command polarity (+) Command polarity (–)
5 fdir Position detector polarity (+)
Position detector polarity (–) 6 7
Synchronized tapping position compensation valid 9 A B C
8 phos Normal (no compensation)
od8x Magnification of excessive error width × 8 times invalid
Magnification of excessive error width × 8 times valid
F zrtn Zero point return direction: CCW

No. Items Details Setting
Set the speed loop proportional gain in synchronized tapping mode.
0 to 1000 (1/s)
tapping speed loop gain proportional term
SP195 VGTI Synchronized tapping speed loop gain integral term
Set the speed loop integral gain in synchronized tapping mode.
0 to1000 (0.1 1/s)
Set the speed loop delay advance gain in synchronized tapping mode. When this parameter is set to "0", PI control is applied.
0 to 1000 (0.1 1/s)
tapping speed loop gain delay advance term
3397 SP197 This is used by Mitsubishi. Set to "0" unless particularly designated.
Set the magnification of speed loop proportional gain with respect to SP194 (VGTP) at the maximum motor speed defined in SP017 (TSP) in synchronized tapping mode.
tapping target value of variable speed loop proportional gain
Set the speed where the speed loop proportional gain change starts during synchronized tapping.
0 to 32767 (r/min)
tapping change starting speed of variable speed loop proportional gain
SP194× (SP198/100)
SP199 SP017
Set the acceleration feed forward gain for selection of gear 000 during synchronized tapping. This parameter should be used when an error of relative position to Z-axis servo is large.
tapping acceleration feed forward gain (gear 1)
Set the acceleration feed forward gain for selection of gear 001 during synchronized tapping.
tapping acceleration feed forward gain (gear 2)
Set the acceleration feed forward gain for selection of gear 010 during synchronized tapping.
tapping acceleration feed forward gain (gear 3)

No. Items Details Setting
SP203 FFC4 Synchronized tapping acceleration feed forward gain (gear 4)
Set the acceleration feed forward gain for selection of gear 011 during synchronized tapping.
Not used. Set to "0". 0 0
3414 SP214 TZRN Synchronized tapping zero point return speed
This parameter is valid when SP193 (SPECT) bitE is set to "0". Set the zero point return speed used when the speed loop changes to the position loop.
0 to 500 (r/min)
3415 SP215 TPDT Synchronized tapping zero point return deceleration rate
This parameter is valid when SP193 (SPECT) bitE is set to "0". Set the deceleration rate where the machine starts to decelerate when it returns to the target stop point during synchronized tapping zero point return. When the machine tends to overshoot at the stop point set a smaller value.
0 to 10000 (pulse)
3416 SP216 TPST Synchronized tapping zero point return shift amount
This parameter is valid when SP193 (SPECT) bitE is set to "0". Set the synchronized tapping zero point position.
3417 SP217 TINP Synchronized tapping in-position width
Set the position error range for output of the in-position during synchronized tapping.
SP218 TODR Synchronized tapping excessive error width
Set the excessive error width during synchronized tapping.
1 to 32767 (pulse) (1 pulse =0.088°)
SP219 IQGT Synchronized tapping current loop gain magnifi- cation 1
Set the magnification of current loop gain (torque component) during synchronized tapping.
SP220 IDGT Synchronized tapping current loop gain magnifi- cation 2
Set the magnification of current loop gain (excitation component) during synchronized tapping.

No. Items Details Setting
3421 SP221 PG2T Synchronized tapping position loop gain 2
Set the second position loop gain when high-gain control is applied during synchronized tapping. When this parameter is not used, set to "0".
0 to 999 (1/s)
3422 SP222 PG3T Synchronized tapping position loop gain 3
Set the third position loop gain when high-gain control is applied during synchronized tapping. When this parameter is not used, set to "0".
0 to 999 (1/s)
3423 SP223 SPDV Speed monitor speed
Set the spindle limit speed in the door open state. (Invalid when 0 is set.) If the spindle end speed exceeds this setting value when the door is open, the speed monitor error (5E) will occur.
0 to 800 (r/min)
3424 SP224 SPDF Speed monitor time
Set the time (continuous) to detect alarms. (Detected instantly when 0 is set.)
0 to 2813 (3.5ms)
3425 SP225 OXKPH Position loop gain magni- fication after orientation gain changeover (H coil)
If gain changeover is valid (SP097: SPEC0-bitC=1) during orientation, set the magnification of each gain changed to after in-position.
0 to 2560 (1/256-fold)
3426 SP226 OXKPL Position loop gain magni- fication after orientation gain changeover (L coil)
0 to 2560 (1/256-fold)
3427 SP227 OXVKP Speed loop proportional gain magnifi- cation after orientation gain changeover
0 to 2560 (1/256-fold)
3428 SP228 OXVKI Speed loop cumulative gain magnifi- cation after orientation gain changeover
If gain changeover is valid (SP097: SPEC0-bitC=1) during orientation, set the magnification of each gain changed to after in-position.
0 to 2560 (1/256-fold)
3429 SP229 OXSFT Orientation virtual target shift amount
Set the amount to shift the target position when orientation virtual target position is valid (SP097: SPEC0-bitD=1).
Use not possible.

No. Items Details Setting
SP233 JL Disturbance observer general inertia scale
Set the ratio of the motor inertia + load inertia and motor inertia.
= ×100 Motor inertia + load inertia
(Normally, set "100" or more. When less than "50" is set, the setting will be invalid.)
SP234 OBS1 Disturbance observer low path filter frequency
Set the frequency of the low path filter for when the disturbance observer is valid.
0 to 1000 (1/s)
Setting (1/s) = 2πf
f: Approx. 1.5 times the disturbance
SP235 OBS2 Disturbance observer gain
Set the gain for the disturbance observer.
3436 SP236 OBS3 This is used by Mitsubishi. Set to "0" unless particularly designated.
SP237 Not used. Set to "0". 0 0
Use not possible. 0 0
SP242 Vavx 0 0
This is used by Mitsubishi. Set to "0" unless particularly designated.
SP244 OPLP 0 0
SP245 PGHS 0 0
SP246 TEST
SP247
Use not possible. 0 0
3449 SP249 SM0 Speed meter speed
Set the motor rotation speed when the speed meter 10V is output. When set to "0", this parameter becomes the same as SP017 (TSP).
0 to 32767 (r/min)
3450 SP250 LM0 Load meter voltage
Set the voltage when the load meter 120% is output. When set to "0", this becomes 10V.
0 to 10 (V)
Use not possible. 0 0

No. Items Details Setting
DA1NO D/A output channel 1 data number
Set the output data number for channel 1 of the D/A output function. When set to "0", the output is speedometer. Refer to "9.4 (1) For D/A output functions".
3454 SP254 DA2NO D/A output channel 2 data number
Set the output data number for channel 2 of the D/A output function. When set to "0", the output is load meter. Refer to "9.4 (1) For D/A output functions".
3455 SP255 DA1MPY DA output channel 1 magnifica- tion
Set the data magnification for channel 1 of the D/A output function. The output magnification is the setting value divided by 256. When set to "0", the output magnification becomes 1-fold, in the same manner as when "256" is set. Refer to "9.4 (1) For D/A output functions".
–32768 to 32767 (1/256-fold)
3456 SP256 DA2MPY DA output channel 2 magnifica- tion
Set the data magnification for channel 2 of the D/A output function. The output magnification is the setting value divided by 256. When set to "0", the output magnification becomes 1-fold, in the same manner as when "256" is set. Refer to "9.4 (1) For D/A output functions".
–32768 to 32767 (1/256-fold)
Standard · range · setting

No. Items Details Setting
RPM BSD
Motor constant (H coil)
This parameter is valid only in the following two conditional cases: (a) In case that SP034 (SFNC2) bit0=1
0000 to FFFF HEX setting
and SP034 (SFNC2) bit2=0 Set the motor constants when using a special motor, not described in the SP040 (MTYP) explanation and when not using the coil changeover motor. (b) In case that SP034 (SFNC2) bit0=1
and SP034 (SFNC2) bit2=1 Set the motor constant of the H coil of the coil changeover motor. (Note) It is not allowed for the user to
change the setting.
RPML BSDL
Motor constant (L coil)
This parameter is valid only in the following conditional case: (a) In case that SP034 (SFNC2) bit0=1
0000 to FFFF HEX setting
and SP034 (SFNC2) bit2=1 Set the motor constant of the L coil of the coil changeover motor. (Note) It is not allowed for the user to
change the setting.

8.4 MDS-C1-SPM The spindle parameter setting and display method will differ according to the NC being used, so refer to Instruction Manual for each NC and the following spindles.
MELDAS AC Servo and Spindle MDS-C1 Series Specifications Manual BNP-C3000
For parameters marked with a (PR) in the tables, turn the NC power OFF after setting. The parameters will be valid after the power is turned ON again. The "fixed control constants" and "fixed control bits" in this section are set by Mitsubishi.
! Do not make remarkable adjustments or changes of the parameters as the operation may
become unstable.
! In the explanation on bits, set all bits not used, including blank bits, to “0”.
No. Items Details Setting
3201 SP001 PGM Magnetic sensor and motor built-in encoder orientation position loop gain
As the set value is larger, the orientation time becomes shorter and servo rigidity is increased. However, vibration is increased and the machine becomes likely to overshoot.
0 to 2000 (0.1 1/s)
3202 SP002 PGE Encoder orientation position loop gain
As the set value is larger, the orientation time becomes shorter and servo rigidity is increased. However, vibration is increased and the machine becomes likely to overshoot.
0 to 2000 (0.1 1/s)
3203 SP003 PGC0 C-axis non-cutting position loop gain
Set the position loop gain in C-axis non-cutting mode. During non-cutting (rapid traverse, etc.) with the C axis control, this position loop gain setting is valid.
1 to 200 (1/s)
3204 SP004 OINP Orientation in-position width
Set the position error range in which an orientation completion signal is output.
SP005 OSP Orientation mode changing speed limit value
Set the motor speed limit value to be used when the speed loop is changed to the position loop in orientation mode. When this parameter is set to "0", SP017 (TSP) becomes the limit value.
0 to 32767 (r/min)
3206 SP006 CSP Orientation mode deceleration rate
As the set value is larger, the orientation time becomes shorter. However, the machine becomes likely to overshoot.
3207 SP007 OPST In-position shift amount for orientation
Set the stop position for orientation. (i) Motor built-in encoder, encoder: Set the value by dividing 360° by 4096. (ii) Magnetic sensor: Divide –5° to +5° by 1024 and put 0° for 0.
(i) 0 to 4095
SP008 Not used. Set to "0". 0 0

No. Items Details Setting
3209 SP009 PGT Synchronized tapping Position loop gain
Set the spindle position loop gain in synchronized tapping mode.
1 to 200 (1/s)
3210 SP010 PGS Spindle synchronous position loop gain
Set the spindle position loop gain in spindle synchronization mode.
1 to 200 (1/s)
Use not possible. 0 0
SP017 TSP Maximum motor speed
Set the maximum motor speed of the spindle.
1 to 32767 (r/min)
SP018 ZSP Motor zero speed
Set the motor speed for which zero-speed output is performed.
1 to 1000 (r/min)
SP019 CSN1 Speed cushion 1
Set the time constant for a speed command from "0" to the maximum speed. (This parameter is invalid in position loop mode.)
1 to 32767 (10ms)
SP020 SDTS Speed detection set value
Set the motor speed so for which speed detection output is performed. Usually, the setting value is 10% of SP017 (TSP).
0 to 32767 (r/min)
3221 SP021 TLM1 Torque limit 1 Set the torque limit rate for torque limit
signal 001.
SP022 VGNP1 Speed loop
Set the speed loop proportional gain in speed control mode. When the gain is increased, response is improved but vibration and sound become larger.
0 to 1000 (1/s)
gain proportional term under speed control
SP023 VGNI1 Speed loop gain integral term under speed control
Set the speed loop integral gain in speed control mode. Usually, set a value in proportion to SP022 (VGNP1).
0 to 1000 (0.1 1/s)
SP024 Use not possible. 0 0
SP025 GRA1 Spindle gear teeth count 1
Set the number of gear teeth of the spindle corresponding to gear 000.
SP026 GRA2 Spindle gear teeth count 2
Set the number of gear teeth of the spindle corresponding to gear 001.
SP027 GRA3 Spindle gear teeth count 3
Set the number of gear teeth of the spindle corresponding to gear 010.
SP028 GRA4 Spindle gear teeth count 4
Set the number of gear teeth of the spindle corresponding to gear 011.
SP029 GRB1 Motor shaft gear teeth count 1
Set the number of gear teeth of the motor shaft corresponding to gear 000.


Set the number of gear teeth of the motor shaft corresponding to gear 001.
Set the number of gear teeth of the motor shaft corresponding to gear 010.
Set the number of gear teeth of the motor shaft corresponding to gear 011.
F E D C B A 9 8 poff ront pycal pychg
7 6 5 4 3 2 1 0 pyst pyoff
bit Name Meaning when set to 0 Meaning when set to 1 0 1 2 3 4 5 6 7 8 9 A
B This is used by Mitsubishi. Set to "0" unless particularly designated. C ront Normal ready ON High-speed ready ON
D This is used by Mitsubishi. Set to "0" unless particularly designated. E
F poff Contactor hold at NC power OFF invalid


7 6 5 4 3 2 1 0 mkc2 mkch Mk3c mts1
bit Name Meaning when set to 0 Meaning when set to 1
2 mkch Coil switch function invalid Coil switch function valid
3 mkc2 Coil switch specification 2 invalid Coil switch specification 2 valid (Note1) (Note2) 4 5 6 7 8 9 A B C D E F
(Note1) To validate bit3(mkc2), NC side needs to prepare. (Note2) Always turn the bit2 at the same time to use bit3.


7 6 5 4 3 2 1 0 mwid lwid hwid (Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
M coil output character- istics change valid 3 4 5 6 7 8 9 A B C D E F


F E D C B A 9 8 nsno nosg
7 6 5 4 3 2 1 0 plgo enco (Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1
Encoder orientation valid 1 2 plgo PLG orientation invalid PLG orientation valid 3 4 5 6 7
No-signal detection invalid A B C D E F
(Note) For bit0 to 2, do not set two bits or more to


F E D C B A 9 8 XFzs pl80 sdt2
7 6 5 4 3 2 1 0 hzrn orm tdn plg2 pftm alty
bit Name Meaning when set to 0 Meaning when set to 1
Semi-closed pulse output signal×2 valid 4 tdn Fixed control bit 5
Orientation start memo valid 7 hzrn 8 sdt2 9 pl80
A B C XFzs Fixed control bit D E F


Set the amplifier type. Set each amplifier type or "0"
7 6 5 4 3 2 1 0 motr
motr Set the motor type. Set "0" when using a special motor.
5 6 7 8 9 A B C D E F


F E D C B A 9 8 amp rtyp
7 6 5 4 3 2 1 0 ptyp
When the CN4 connector of the drive unit and the power supply are connected, setting below is necessary. To validate the external emergency stop function, add 40h.
3 Set- ting 0x 1x 2x 3x 4x 5x 6x 7x 8x
8 Set the regenerative resistor type when MDS-A-CR is used.
A 0 MDS-C1-CV (Setting when using power supply regeneration)
This parameter is used to set the C-axis detector range. Set "0" for this parameter. "2" is used by Mitsubishi for testing.

No. Items Details Setting
This parameter is used to set the synchronous tapping or spindle synchronous detector range. Set "0" for this parameter.
tapping, spindle synchronous detector range
Set a frequency of data communication with NC.
3245 SP045 CSNT Dual cushion timer
Set the cycle to add the increment values in the dual cushion process. When this setting value is increased, the dual cushion will increase, and the changes in the speed during acceleration/deceleration will become gradual.
0 to 1000 (ms)
For an acceleration/deceleration time constant defined in SP019 (CSN1) , this parameter is used to provide smooth movement only at the start of acceleration/deceleration. As the value of this parameter is smaller, it moves smoother but the acceleration/deceleration time becomes longer. To make this parameter invalid, set "0".
Set the reset hysteresis width for a speed detection set value defined in SP020 (SDTS).
0 to 1000 (r/min)
SP048 SUT Speed reach range
Set the speed deviation rate with respect to the commanded speed for output of the speed reach signal.
3249 SP049 TLM2 Torque limit 2 Set the torque limit rate for the torque limit signal 010.
3250 SP050 TLM3 Torque limit 3 Set the torque limit rate for the torque limit signal 011.
3251 SP051 TLM4 Torque limit 4 Set the torque limit rate for the torque limit signal 100.
3252 SP052 TLM5 Torque limit 5 Set the torque limit rate for the torque limit signal 101.
3253 SP053 TLM6 Torque limit 6 Set the torque limit rate for the torque limit signal 110.
3254 SP054 TLM7 Torque limit 7 Set the torque limit rate for the torque limit signal 111.
Set the timer value until the excessive speed deviation alarm is output. The value of this parameter should be longer than the acceleration/deceleration time.
0 to 60 (s) 12

No. Items Details Setting
SP056 Use not possible. 0 0
SP057 STOD Constant → excessive judgment value
Set the value for judging when changing from a constant to excessive speed command.
0 to 50 (r/min)
SP058 SDT2 2nd speed detection speed
Set the speed for turning the 2nd speed detection ON. (This is valid only when SP038: SFNC6-bit8 is set to "1".) If the speed drops below this set speed, the 2nd speed detection will turn ON. When the speed reaches this set speed +15r/min or more, the 2nd speed detection will turn OFF. If SP034: SFNC2-bit1 is set to "1", this will be the medium-speed and high-speed coil changeover speed. The speed detection reset width follows the SP047 (speed detection reset width) setting.
0 to 32767 (r/min)
SP059 MKT Winding changeover base shut-off timer
Set the base shut-off time for contactor switching at winding changeover. Note that the contactor may be damaged with burning if the value of this parameter is too small.
50 to 10000 (ms)
SP060 MKT2 Current limit timer after winding changeover
Set the current limit time to be taken after completion of contactor switching at winding changeover.
0 to 10000 (ms)
SP061 MKIL Current limit value after winding changeover
Set the current limit value during a period defined in SP060 (MKT2) after completion of contactor switching at winding changeover.
SP062 Not used. Set to "0". 0 0
SP063 OLT Overload alarm detection time
Set the time constant for detection of the motor overload alarm.
0 to 1000 (s)
SP064 OLL Overload alarm detection level
Set the detection level of the motor overload alarm.
SP065 VCGN1 Target value
Set the magnification of speed loop proportional gain with respect to SP022 (VGNP1) at the maximum motor speed defined in SP017 (TSP).
of variable speed loop proportional gain
Standard · range · setting


Set the speed when the speed loop proportional gain change starts.
Set the speed where the current loop gain change starts.
Set the speed where the current loop gain change ends.
SP069 VIGN Target value of variable current loop gain
Set the magnification of current loop gain (torque component and excitation component) for a change ending speed defined in SP068 (VIGWB). When this parameter is set to "0", the magnification is 1.
0 to 6000 6001 to 8000 5000 8000 45 8001 or more 5000 10000 64
When machine vibration occurs in speed and position control, set the frequency of the required vibration suppression. Note that a value of 100Hz or more is set. Set to "0" when not used.

No. Items Details Setting
3276 SP076 FONS Machine resonance suppression filter operation speed
When the vibration increases in motor stop (ex. in orientation stop) when the machine vibration suppression filter is operated by SP070, operate the machine vibration suppression filter at a speed of this parameter or more. When set to "0", this is validated for all speeds.
0 to 32767 (r/min)
SP077 TDSL Fixed control constant
Set by Mitsubishi. Set "14" unless designated in particular.
SP078 FPWM Fixed control
Set by Mitsubishi. Set "1" unless designated in particular.
SP079 Use not possible. 0 0
3280 SP080 SWTD Fixed control constant
Set by Mitsubishi. Set "0" unless designated in particular.
Use not possible. 0 0
SP087 DIQM Target value
Set the minimum value of variable torque limit at deceleration.
of variable torque limit magnifica- tion at deceleration
SP088 DIQN Speed for starting change of variable torque limit magnifica- tion at deceleration
Set the speed where the torque limit value at deceleration starts to change.
0 to 32767 (r/min)
Inversely proportional to speed
SP088 SP017
SP089
Use not possible. 0 0
SP093 ORE Tolerable pulse check error
Set this when detecting the pulse detector's pulse mistakes. (Valid only for full close control.)
SP094 LMAV Load meter
Set the filter time constant of load meter output. When "0" is set, a filter time constant is set to 100ms.
0 to 32767 (2ms)
SP095 VFAV Fixed control
Set by Mitsubishi. Set "0" unless designated in particular.

No. Items Details Setting
SP096 EGAR Encoder gear ratio
Set the gear ratio between the spindle end and the encoder end (except for the motor-built-in encoder) as indicated below.
0 1 : 1 1 1 : 2 2 1 : 4 3 1 : 8 4 1 : 16
(Note) Use a combination so that the encoder
end is slower than the spindle end.
Set the orientation specifications in bit units.
0000 to FFFF HEX setting
F E D C B A 9 8 ostp orze ksft gchg ips2
7 6 5 4 3 2 1 0 vg8x fdir osc1 dmin odi2 odi1
(Note) Always set "0" for the empty bits.
bit Name Meaning when set to 0 Meaning when set to 1 0 odi1
Orientation rotation direction 00: Previous (the direction in which the motor has so far rotated under speed control) 01: Forward rotation 10: Backward rotation 11: Prohibited (Same as setting value = 10)
2 dmin Orientation in-position advance invalid
Orientation in-position advance valid 3
4 osc1 Indexing speed clamp invalid
Indexing speed clamp valid
7 vg8x Speed gain *1/8 during torque limit valid
Speed gain *1/8 during torque limit invalid 8 9 A ips2 2nd in-position invalid 2nd in-position valid B
C gchg Gain changeover during orientation invalid
Gain changeover during orientation valid
D ksft Orientation virtual target shift invalid
Orientation virtual target shift valid E orze F ostp
This is used by Mitsubishi. Set to "0" unless particularly designated.
In-position advance (bit 2)
0 (invalid) 1 (valid)
In-position signal in OINP width=1 Control output 4/ bit 4=1 Second in-position signal=0 Control output 4/ bit F=1
In-position signal in OINP width=1 Control output 4/ bit 4=1 Second in-position signal=0 Control output 4/ bit F=0
In-position signal in DINP width=1 Control output 4/ bit 4=1 Second in-position signal in OINP width = 0 Control output 4/ bit F=1

No. Items Details Setting
SP098 VGOP Speed loop
Set the speed loop proportional gain in orientation mode. When the gain is increased, rigidity is improved in the orientation stop but vibration and sound become larger.
0 to 2000 (1/s)
gain propor- tional term in orientation mode
SP099 VGOI Orientation mode speed loop gain integral term
Set the speed loop integral gain in orientation mode.
0 to 2000 (0.1 1/s)
Set a loop gain delay advance gain in orientation mode. When this parameter is set to "0", PI control is applied.
0 to 1000 (0.1 1/s)
mode speed loop gain delay advance term
SP101 DINP Orientation advance in-position width
When using the orientation in-position advance function, set the in-position width that is larger than the normal in-position width defined in SP004 (OINP).
SP102 OODR Excessive error
Set the excessive error width in orientation mode.
0 to 32767 (1/4 pulse) (1 pulse= 0.088°)
value in orientation mode
SP103 FTM Index positioning completion OFF time timer
Set the time for forcedly turn OFF the index positioning completion signal (different from the orientation completion signal) after the leading edge of the indexing start signal.
0 to 10000 (ms)
SP104 TLOR Torque limit
Set the torque limit value for orientation in-position output. If the external torque limit signal is input, the torque limit value set by this parameter is made invalid.
value for orientation servo locking
SP105 IQG0 Current loop gain magnifica- tion 1 in orientation mode
Set the magnification for current loop gain (torque component) at orientation completion.
SP106 IDG0 Current loop gain magnifica- tion 2 in orientation mode
Set the magnification for current loop gain (excitation component) at orientation completion.
3307 SP107 CSP2 Deceleration
Set the deceleration rate in orientation mode corresponding to the gear 001. When this parameter is set to "0", same as SP006 (CSP).
rate 2 in orientation mode
3308 SP108 CSP3 Deceleration
Set the deceleration rate in orientation mode corresponding to the gear 010. When this parameter is set to "0", same as SP006 (CSP).
rate 3 in orientation mode

No. Items Details Setting
3309 SP109 CSP4 Deceleration rate 4 in orientation mode
Set the deceleration rate in orientation mode corresponding to the gear 011. When this parameter is set to "0", same as SP006 (CSP).
Use not possible. 0
3314 SP114 OPER Orientation pulse miss check value
An alarm "5C" will occur if the pulse miss value at the orientation stop exceeds this setting value. (Note that this is invalid when set to "0".) In this parameter, set the value to fulfill the following conditions. SP114 setting value > 1.5 × SP004 (orientation in-position width)
3315 SP115 OSP2 Orientation motor speed clamp value 2
When the orientation clamp speed is changed by the control input, this parameter setting will be used instead of SP005: OSP. Indexing speed clamp valid This parameter is used when (SP097: SPEC0-bit4 = 1).
0 to 32767 (r/min)
SP116 Use not possible. 0 0
3317 SP117 ORUT Set by Mitsubishi. Set "0" unless designated in particular.
3318 SP118 ORCT Number of orientation retry times
Set the number of times to retry when an orientation or feedback error occurs. The warning (A9) is issued while retrying orientation, and an alarm (5C) is issued when the set number of times is exceeded.
0 to 100 (time)
3319 SP119 MPGH Orientation position gain H winding compensa- tion magnifi- cation
Set the compensation magnification of the orientation position loop gain for the H winding. H winding orientation position loop gain = SP001 (or SP002) × SP119/256 When set to "0", will become the same as SP001 or SP002.
0 to 2560 (1/256-fold)
3320 SP120 MPGL Orientation position gain L winding compensa- tion magnifi- cation
Set the compensation magnification of the orientation position loop gain for the L winding. L winding orientation position loop gain = SP001 (or SP002) × SP120/256 When set to "0", will become the same as SP001 or SP002.
0 to 2560 (1/256-fold)

No. Items Details Setting
3321 SP121 MPCSH Orientation deceleration rate H winding compensa- tion magnifi- cation
Set the compensation magnification of the orientation deceleration rate for the H winding. Orientation deceleration rate for the H winding = SP006 × SP121/256 When set to "0", will become the same as SP006.
0 to 2560 (1/256-fol d)
3322 SP122 MPCSL Orientation deceleration rate L winding compensa- tion magnifi- cation
Set the compensation magnification of the orientation deceleration rate for the L winding. Orientation deceleration rate for the L winding = SP006 × SP122/256 When set to "0", will become the same as SP006.
0 to 2560 (1/256-fol d)
Use not possible. 0 0
3326 SP126 MPGH Orientation position gain M coil com- pensation
Set this to set the orientation position loop gain for the coil changeover motor to the M coil's unique value.
0 to 2560 (1/256- fold)
3327 SP127 MPCSM Orientation deceleration rate M coil compensa- tion
Set this to set the orientation deceleration rate for the coil motor to the M coil's unique value.
0 to 2560 (1/256- fold)
3328 SP128 OXKPM Position loop gain magnifi- cation after orientation gain change- over (M coil)
Set the M coil gain magnification to be used after in-position when gain changeover is valid (SP097: SPEC0-bitC=1) during orientation.
0 to 2560 (1/256- fold)


F E D C B A 9 8 zrtn ptyp fb9x zrtd zrn2 zdir ztyp
7 6 5 4 3 2 1 0 vg8x fdir phos rtrn fclx
bit Name Meaning when set to 0 Meaning when set to 1
0 fclx Closed loop Semi-closed loop (Gear 1 : 1 only) 1
7 vg8x Speed gain × 1/8 during torque limit valid
Z-phase rising polarity (–) A B zrn2 C zrtd
This is used by Mitsubishi. Set to "0" unless particularly designated.
3330 SP130 PGC1 First position loop gain for cutting on C-axis
Set the position loop gain when the first gain is selected for C axis cutting.

No. Items Details Setting
3331 SP131 PGC2 Second position loop gain for cutting on C-axis
Set the position loop gain when the second gain is selected for C axis cutting.
1 to 200 (1/s)
3332 SP132 PGC3 Third position loop gain for cutting on C-axis
Set the position loop gain when the third gain is selected for C-axis cutting.
1 to 200 (1/s)
3333 SP133 PGC4 Stop position loop gain for cutting on C-axis
Set the position loop gain for stopping when carrying out C-axis cutting.
1 to 200 (1/s)
SP134 VGCP0∗ C-axis non-cutting speed loop gain proportional item
Set the speed loop proportional gain in C-axis non-cutting mode.
0 to 5000 (1/s)
SP135 VGCI0 C-axis non-cutting speed loop gain integral item
Set the speed loop integral gain in C-axis non-cutting mode.
0 to 5000 (0.1 1/s)
SP136 VGCD0 C-axis non-cutting speed loop gain delay advance item
Set the speed loop delay advance gain in C-axis non-cutting mode. When this parameter is set to "0", PI control is exercised.
0 to 5000 (0.1 1/s)
SP137 VGCP1 First speed loop gain proportional item for C-axis cutting
Set the speed loop proportional gain when the first gain is selected for C-axis cutting.
0 to 5000 (1/s)
SP138 VGCI1 First speed loop gain integral item for cutting on C-axis
Set the speed loop integral gain when the first gain is selected for C-axis cutting.
0 to 5000 (0.1 1/s)
SP139 VGCD1 First speed loop gain delay advance item for cutting on C-axis
Set the speed loop delay advance gain when the first gain is selected for curing on the C-axis. When this parameter is set to "0", PI control is applied.
0 to 5000 (0.1 1/s)
SP140 VGCP2 Second speed loop gain proportional item for cutting on C-axis
Set the speed loop proportional gain when the second gain is selected for C-axis cutting.
0 to 5000 (1/s)
SP141 VGCI2 Second speed loop gain integral item for cutting on C-axis
Set the speed loop integral gain when the second gain is selected for C-axis cutting.
0 to 5000 (0.1 1/s)
SP142 VGCD2 Second speed loop gain delay advance item for cutting on C-axis
Set the speed loop delay advance gain when the second gain is selected for C-axis cutting. When this parameter is set to "0", PI control is applied.
0 to 5000 (0.1 1/s)
Standard · range · setting

No. Items Details Setting
SP143 VGCP3 Third speed loop
Set the speed loop proportional gain when the third gain is selected for C-axis cutting.
0 to 5000 (1/s)
gain proportional item for cutting on C-axis
SP144 VGCI3 Third speed loop gain integral item for cutting on C-axis
Set the speed loop integral gain when the third gain is selected for C-axis cutting.
0 to 5000 (0.1 1/s)
SP145 VGCD3 Third speed loop
Set the speed loop delay advance gain when the third gain is selected for C-axis cutting. When this parameter is set to "0", PI control is applied.
0 to 5000 (0.1 1/s)
gain delay advance item for cutting on C-axis
SP146 VGCP4 Speed loop gain
Set the speed loop proportional gain when C-axis cutting is stopped.
0 to 5000 (1/s)
propor- tional item for stop of cutting on C-axis
SP147 VGCI4 Speed loop gain integral item for stop of cutting on C-axis
Set the speed loop integral gain when C-axis cutting is stopped.
0 to 5000 (0.1 1/s)
SP148 VGCD4 Speed loop gain
Set the speed loop delay advance gain when C-axis cutting is stopped. When this parameter is set to "0", PI control is applied.
0 to 5000 (0.1 1/s)
delay advance item for stop of cutting on C-axis
3349 SP149 CZRN C-axis zero point return speed
This parameter is valid when SP129 (SPECC) bitE is set to "0". Set the zero point return speed used when the speed loop changes to the position loop.
1 to 500 (r/min)
3350 SP150 CPDT C-axis zero point return deceleration point
This parameter is valid when SP129 (SPECC) bitE is set to "0". Set the deceleration rate where the machine starts to decelerate when it returns to the target stop point during C-axis zero point return. When the machine tends to overshoot at the stop point, set the smaller value.
3351 SP151 CPSTL C-axis zero point return shift amount (low byte)
This parameter is valid when SPECC (SP129) bitE is set to "0". Set the C-axis zero point position.
HEX setting 00000000 to FFFFFFFF (1/1000°)
3352 SP152 CPSTH C-axis zero point return shift amount (high byte)
Standard · range · setting

No. Items Details Setting
3353 SP153 CINP C-axis in-position width
Set the position error range in which the in-position signal is output on the C-axis.
0000 to FFFF (1/1000°) HEX setting
SP154 CODRL Excessive error
Set the excessive error width on the C-axis.
HEX setting 00000000 to FFFFFFFF (1/1000°)
width on C-axis (low byte)
SP155 CODRH Excessive error
width on C-axis (high byte)
3356 SP156 OVSH C-axis overshoot compensa- tion
Set this to prevent overshooting when shifting from movement to stopping with C-axis control. (Set this referring to the load meter display when overshooting occurred.)
Not used. Set to "0". 0 0
SP158 Not used. Set to "0". 0 0
SP159 Use not possible. 0 0
SP160 Use not possible. 0 0
SP161 IQGC0 Current loop gain magnifi- cation 1 for non-cutting on C-axis
Set the magnification of current loop gain (torque component) for C-axis non-cutting.
SP162 IDGC0 Current loop gain magnifi- cation 2 for non-cutting on C-axis
Set the magnification of current loop gain (excitation component) for C-axis non-cutting.
SP163 IQGC1 Current loop gain magnifi- cation 1 for cutting on C-axis
Set the magnification of current loop gain (torque component) for C-axis cutting.
SP164 IDGC1 Current loop gain magnifi- cation 2 for cutting on C-axis
Set the magnification of current loop gain (excitation component) for C-axis cutting.
3365 SP165 PG2C C-axis position loop gain 2
Set the second position loop gain when high-gain control is carried out for control of the C-axis. This parameter is applied to all the operation modes of C-axis control. When this function is not used, assign "0".
0 to 999 (1/s)
Standard · range · setting

No. Items Details Setting
3366 SP166 PG3C C-axis position loop gain 3
Set the third position loop gain when high-gain control is carried out for control of the C-axis. This parameter is applied to all the operation modes of C-axis control. When this function is not used, assign "0".
0 to 999 (1/s)
PGU Position loop gain for increased spindle holding force
Set the position loop gain for when the disturbance observer is valid.
0 to 100 (1/s)
VGUP Speed loop gain proportional item for increased spindle holding force
Set the speed loop gain proportional item for when the disturbance observer is valid.
0 to 5000 (1/s)
VGUI Speed loop gain integral item for increased spindle holding force
Set the speed loop gain integral item for when the disturbance observer is valid.
0 to 5000 (0.1 1/s)
VGUD Speed loop gain delay advance item for increased spindle holding force
Set the speed loop gain delay advance item for when the disturbance observer is valid.
0 to 5000 (0.1 1/s)
Not used. Set to "0". 0 0

No. Items Details Setting
Set the spindle synchronous specifications in bit units.
0000 to FFFF HEX setting
F E D C B A 9 8 odx8 phos
7 6 5 4 3 2 1 0 fdir mach fclx
bit Name Meaning when set to 0 Meaning when set to 1 0 fclx Closed loop Semi-closed loop 1 2
3 mach Automatic coil change- over during spindle synchronization invalid
Automatic coil change- over during spindle synchronization valid 4
5 fdir Position detector direc- tion (positive direction)
Position detector direc- tion (negative direction) 6 7 8 9 A B C
Magnification of excessive error width × 8 times valid E F (Used with SPJ)
odx8 Magnification of excessive error width × 8 times invalid
SP178 VGSP Spindle synchronous speed loop gain propor- tional term
Set the speed loop proportional gain in spindle synchronous mode.
0 to 2000 (1/s)
SP179 VGSI Spindle synchronous speed loop gain integral term
Set the speed loop integral gain in spindle synchronous mode.
0 to 2000 (0.1 1/s)
SP180 VGSD Spindle synchronous speed loop gain delay advance term
Set the speed loop delay advance gain in spindle synchronous mode. When this parameter is set to "0", PI control is applied.
0 to 1000 (0.1 1/s)
SP181 VCGS Spindle synchronous Target value of variable speed loop proportional gain
Set the magnification of speed loop proportional gain with respect to SP178 (VGSP) at the maximum speed defined in SP017 (TSP) in spindle synchronous mode.

No. Items Details Setting
SP182 VCSS Spindle synchronous Change starting speed of variable speed loop proportional gain
Set the speed when the speed loop proportional gain change starts in the spindle synchronous mode.
0 to 32767 (r/min)
SP178× (SP181/100)
SP182 SP017
3383 SP183 SYNV Spindle synchronous Sync match- ing speed
For changeover from the speed loop to the position loop in the spindle synchronous mode, set a speed command error range for output of the synchronous speed matching signal.
0 to 1000 (r/min)
SP184 FFCS Spindle synchronous Acceleration rate feed forward gain
Set the acceleration rate feed forward gain in the spindle synchronous mode. This parameter is used only with the SPJ2.
3385 SP185 SINP Spindle synchronous In-position width
Set the position error range for output of the in-position signal in the spindle synchronous mode.
SP186 SODR Spindle synchronous Excessive error width
Set the excessive error width in the spindle synchronous mode.
1 to 32767 ( pulse) (1 pulse =0.088°)
SP187 IQGS Spindle synchronous Current loop gain magnifi- cation1
Set the magnification of current loop gain (torque component) in the spindle synchronous mode.
SP188 IDGS Spindle synchronous Current loop gain magnifi- cation 2
Set the magnification of current loop gain (excitation component) in the spindle synchronous mode.
3389 SP189 PG2S Spindle synchronous Position loop gain 2
Set the second position loop gain when high-gain control is carried out in the spindle synchronous mode. When this parameter function is not used, set to "0".
0 to 999 (1/s)


3390 SP190 PG3S Spindle synchronous Position loop gain 3
Set the third position loop gain when high-gain control is carried out in the spindle synchronous mode. When this parameter function is not used, set to "0".
F E D C B A 9 8 zrtn ptyp od8x phos
7 6 5 4 3 2 1 0 fdir cdir pyfx rtrn fclx
bit Name Meaning when set to 0 Meaning when set to 1
0 fclx Closed loop Semi-closed loop (Gear 1 : 1 only) 1
Position monitor during ready OFF valid 3 4 cdir Command polarity (+) Command polarity (–)
Synchronized tapping position command compensation (for synchronization with high-gain servo) 9 A B C
od8x Magnification of excessive error width × 8 times invalid
Magnification of excessive error width × 8 times valid

No. Items Details Setting
SP194 VGTP Synchronized tapping speed loop gain proportional term
Set the speed loop proportional gain in synchronized tapping mode.
0 to 2000 (1/s)
SP195 VGTI Synchronized tapping speed loop gain integral term
Set the speed loop integral gain in synchronized tapping mode.
0 to2000 (0.1 1/s)
SP196 VGTD Synchronized tapping speed loop gain delay advance term
Set the speed loop delay advance gain in synchronized tapping mode. When this parameter is set to "0", PI control is applied.
0 to 1000 (0.1 1/s)
SP197 Use not possible. 0 0
SP198 VCGT Synchronized tapping target value of variable speed loop proportional gain
Set the magnification of speed loop proportional gain with respect to SP194 (VGTP) at the maximum motor speed defined in SP017 (TSP) in synchronized tapping mode.
SP199 VCST Synchronized tapping change starting speed of variable speed loop proportional gain
Set the speed where the speed loop proportional gain change starts during synchronized tapping.
0 to 32767 (r/min)
SP194× (SP198/100)
SP199 SP017

No. Items Details Setting
SP200 FFC1 Synchronized tapping acceleration feed forward gain (gear 1)
Set the acceleration feed forward gain for selection of gear 000 during synchronized tapping. This parameter should be used when an error of relative position to Z-axis servo is large.
SP201 FFC2 Synchronized tapping acceleration feed forward gain (gear 2)
Set the acceleration feed forward gain for selection of gear 001 during synchronized tapping.
SP202 FFC3 Synchronized tapping acceleration feed forward gain (gear 3)
Set the acceleration feed forward gain for selection of gear 010 during synchronized tapping.
SP203 FFC4 Synchronized tapping acceleration feed forward gain (gear 4)
Set the acceleration feed forward gain for selection of gear 011 during synchronized tapping.
This is used by Mitsubishi. Set to "0" unless particularly designated.
3406 SP206 GCK Reverse run detection error detection width
When the motor moves (including movement with external force), the motor overrun alarm (3E) will be detected even if the speed command is 0 (including position control stop command) during servo ON (gate ON). Set the movement amount to be detected as an alarm. 0: Detect with 10° motor movement amount (Recommended setting) 1: Detect with 20° motor movement amount 2: Detect with 40° motor movement amount

No. Items Details Setting
3407 SP207 GDL Sequential mode startup timing
To carry out spindle synchronization or C-axis control in the both-chuck state with no movement immediately after the power is turned ON, set this parameter so that the reverse run detection function will function correctly. Set so that servo ON timing for the opposing spindle has the combination of (1) and (2) shown in the drawing below. 0: Servo turns ON simultaneously with servo ON command, and servo ON status is returned immediately. 1: Gate turns ON at pattern (1) shown below, and servo ON status is returned two seconds later. 2: Gate turns ON at pattern (2) shown below, and servo ON status is returned two seconds later.
3408 SP208 W2 This is used by Mitsubishi. Set to "0" unless particularly designated.
Not used. Set to "0". 0 0
3414 SP214 TZRN Synchronized tapping zero point return speed
This parameter is valid when SP193 (SPECT) bitE is set to "0". Set the zero point return speed used when the speed loop changes to the position loop.
3415 SP215 TPDT Synchronized tapping zero point return deceleration rate
This parameter is valid when SP193 (SPECT) bitE is set to "0". Set the deceleration rate where the machine starts to decelerate when it returns to the target stop point during synchronized tapping zero point return. When the machine tends to overshoot at the stop point set a smaller value.
0 to 10000 (pulse)
3416 SP216 TPST Synchronized tapping zero point return shift amount
This parameter is valid when SP193 (SPECT) bitE is set to "0". Set the synchronized tapping zero point position.

No. Items Details Setting
3417 SP217 TINP Synchronized tapping in-position width
Set the position error range for output of the in-position during synchronized tapping.
SP218 TODR Synchronized tapping excessive error width
Set the excessive error width during synchronized tapping.
1 to 32767 (pulse) (1 pulse =0.088°)
SP219 IQGT Synchronized tapping current loop gain magnifi- cation 1
Set the magnification of current loop gain (torque component) during synchronized tapping.
SP220 IDGT Synchronized tapping current loop gain magnifi- cation 2
Set the magnification of current loop gain (excitation component) during synchronized tapping.
3421 SP221 PG2T Synchronized tapping position loop gain 2
Set the second position loop gain when high-gain control is applied during synchronized tapping. When this parameter is not used, set to "0".
0 to 999 (1/s)
3422 SP222 PG3T Synchronized tapping position loop gain 3
Set the third position loop gain when high-gain control is applied during synchronized tapping. When this parameter is not used, set to "0".
0 to 999 (1/s)
3423 SP223 SPDV Speed monitor speed
Set the spindle limit speed in the door open state. (Invalid when 0 is set.) If the spindle end speed exceeds this setting value when the door is open, the speed monitor error (5E) will occur.
0 to 800 (r/min)
3424 SP224 SPDF Speed monitor time
Set the time (continuous) to detect alarms. (Detected instantly when 0 is set.)
0 to 2813 (3.5ms)
Standard · range · setting

No. Items Details Setting
3425 SP225 OXKPH Position loop gain magni- fication after orientation gain changeover (H coil)
If gain changeover is valid (SP097: SPEC0-bitC=1) during orientation, set the magnification of each gain changed to after in-position.
0 to 2560 (1/256-fold)
3426 SP226 OXKPL Position loop gain magni- fication after orientation gain changeover (L coil)
0 to 2560 (1/256-fold)
3427 SP227 OXVKP Speed loop proportional gain magnifi- cation after orientation gain changeover
0 to 2560 (1/256-fold)
3428 SP228 OXVKI Speed loop cumulative gain magnifi- cation after orientation gain changeover
If gain changeover is valid (SP097: SPEC0-bitC=1) during orientation, set the magnification of each gain changed to after in-position.
0 to 2560 (1/256-fold)
3429 SP229 OXSFT Orientation virtual target shift amount
Set the amount to shift the target position when orientation virtual target position is valid (SP097: SPEC0-bitD=1).
Use not possible.
SP233 JL Disturbance observer general inertia scale
Set the ratio of the motor inertia + load inertia and motor inertia.
= ×100 Motor inertia + load inertia
(Normally, set "100" or more. When less than "50" is set, the setting will be invalid.) To calculate speed loop gain with general inertia scale:
The effective proportional gain and effective cumulative gain during the speed control are changed at the set scale.
SP234 OBS1 Disturbance observer low path filter frequency
Set the frequency of the low path filter for when the disturbance observer is valid.
0 to 1000 (1/s)
Setting (1/s) = 2πf
f: Approx. 1.5 times the disturbance

No. Items Details Setting
SP235 OBS2 Disturbance observer gain
Set the gain for the disturbance observer. 0 to 500 (%) 0
3436 SP236 OBS3 Fixed control constant
This is used by Mitsubishi. Set to "0" unless particularly designated.
This is used by Mitsubishi. Set to "0" unless particularly designated.
SP239 SEZT
SP240 Use not possible. 0 0
SP241 Use not possible. 0 0
SP242 Vavx 0 0
This is used by Mitsubishi. Set to "0" unless particularly designated.
SP244 OPLP Use not possible. 0 0
This is used by Mitsubishi. Set to "0" unless particularly designated.
SP247
Use not possible. 0 0
3449 SP249 SM0 Speed meter speed
Set the motor rotation speed when the speed meter 10V is output. When set to "0", this parameter becomes the same as SP017 (TSP).
0 to 32767 (r/min)
3450 SP250 LM0 Load meter voltage
Set the voltage when the load meter 120% is output. When set to "0", this becomes 10V.
0 to 10 (V)
Use not possible. 0 0

No. Items Details Setting
DA1NO D/A output channel 1 data number
Set the output data number for channel 1 of the D/A output function. When set to "0", the output is speedometer. Refer to "9.4 (1) For D/A output functions".
3454 SP254 DA2NO D/A output channel 2 data number
Set the output data number for channel 2 of the D/A output function. When set to "0", the output is load meter. Refer to "9.4 (1) For D/A output functions".
3455 SP255 DA1MPY DA output channel 1 magnifica- tion
Set the data magnification for channel 1 of the D/A output function. The output magnification is the setting value divided by 256. When set to "0", the output magnification becomes 1-fold, in the same manner as when "256" is set. Refer to "9.4 (1) For D/A output functions".
–32768 to 32767 (1/256-fold)
3456 SP256 DA2MPY DA output channel 2 magnifica- tion
Set the data magnification for channel 2 of the D/A output function. The output magnification is the setting value divided by 256. When set to "0", the output magnification becomes 1-fold, in the same manner as when "256" is set. Refer to "9.4 (1) For D/A output functions".
–32768 to 32767 (1/256-fold)
RPM BSD
Motor constant (H coil)
This parameter is valid only in the following two conditional cases: (a) In case that SP034 (SFNC2) bit0=1
0000 to FFFF HEX setting
and SP034 (SFNC2) bit2=0 Set the motor constants when using a special motor, not described in the SP040 (MTYP) explanation and when not using the coil changeover motor. (b) In case that SP034 (SFNC2) bit0=1
and SP034 (SFNC2) bit2=1 Set the motor constant of the H coil of the coil changeover motor. (Note) It is not allowed for the user to
change the setting.
RPML BSDL
Motor constant (L coil)
This parameter is valid only in the following conditional case: (a) In case that SP034 (SFNC2) bit0=1
0000 to FFFF HEX setting
and SP034 (SFNC2) bit2=1 Set the motor constant of the L coil of the coil changeover motor. (Note) It is not allowed for the user to
change the setting.


No. of channels 2ch Output cycle 444µs (min. value) Output precision 8bit
0V to +5V (zero) to +10V, 0V to +10V during meter output Output scale setting 1/256 to ±128 tiems
CN9 connector MO1 = 9 pin MO2 = 19 pin GND = 11pin


(2) Setting the output data
Input the No. of the data to be output to each D/A output channel.
# No. Abbrev Parameter name 3453 SP253 DA1NO D/A output channel 1 data No. 3454 SP254 DA2NO D/A output channel 2 data No.
No. Output data Original data unit
for output scale (Setting values in
10V=max. speed (0=0V)
0 Depends on the max. speed
3.55ms
10V=120% load (0=0V) 0 Rated 12%/V 3.55ms
2 Current command Rated 100% = 4096 8 Rated 20%/V 3.55ms
3 Current feedback Rated 100% = 4096 8 Rated 20%/V 3.55ms
4 Speed feedback r/min 13 500rpm/V 3.55ms 5 – 6 Position droop 1° = (64000/65536) 671 10°/V 888µs 7 –
8 Feedrate (F∆T) 1° = (64000/65536) 629 (When communicating by 3.5ms)
HEX Bit correspondence 3.55ms
84 Control output 1 85 Control output 2 86 Control output 3 87 Control output 4
HEX Bit correspondence 3.55ms
125 Saw-tooth wave test output
0 (256) Cycle 227.5ms 444µs
126 Rectangular wave test output
0 (256) Cycle 1.7ms 444µs
127 2.5V(data0) test output
0 (256) – 444µs

(3) Setting the output scale
# No. Abbrev Parameter name 3455 SP255 DA1MPY D/A output channel 1 magnification 3456 SP256 DA2MPY D/A output channel 2 magnification Usually, the standard setting value is set for the output scale (SV063, SV 064). When “0” is set, the output will be made as well as when “256” is set.
SP255 10 [V] DATA x 256 x 256 (8bit) + 5 [V] (offset) = Output voltage [V]
(Example) When outputting the position droop with 10°/V.
640000 671 10 65536 x 256 x 256 + 5 = 5.999 [V]

Machine error compensation includes two independent functions: memorized pitch error compensation and memorized relative position compensation.
(1) Memorized pitch error compensation
According to the specified parameters‚ this method compensates an axis feed error caused by a ball screw pitch error‚ etc. With the reference point defined as the base‚ as shown in the following figure, set the compensation amount in the division points obtained by equally dividing the machine coordinates. The compensation amount can be set by either the absolute or incremental system. Select the desired method with the "#4000 Pinc". Machine position is compensated between division points n and n+1 as much as compensation amount between them by linear approximation.

Relationship between the compensation amount and machine position

(2) Memorized relative position compensation
This method‚ according to the parameters specified in advance‚ compensates the relative position error between two orthogonal axes caused by deflection of the moving stand. For this‚ as shown in the following figure‚ specify the compensation amount in the compensation axis direction in the division points obtained by equally dividing the machine coordinates of the base axis. The base axis is one of the two orthogonal axes to which relative position compensation applies. This axis is used as the criterion for relative-error measurement. The compensation axis is the coordinate axis that is orthogonal to the base axis. The compensation is actually made for this coordinate axis. The section between division points n and n+1 is compensated smoothly by linear approximation.

Relationship between the compensation amount and machine position


Specify whether the incremental volume method or absolute volume method is to be used to set machine error offset data.
# Item Details Setting range 4001 cmpax Basic axis Specify the basic axis address for machine error compensation. 1) For pitch error compensation‚ set the name of the axis to be compensated. 2) For relative position compensation‚ set the name of the axis to be the base axis.
X, Y, Z, U, V, W, A, B, or C axis address
4002 drcax Compensation axis
Set the compensation axis address for machine error compensation. 1) For pitch error compensation‚ set the same axis name as "#4001 cmpax". 2) For relative position compensation‚ set the name of the axis to be actually compensated.
X, Y, Z, U, V, W, A, B, or C axis address
4003 rdvno Division point number at reference point position
Set the compensation data No. corre- sponding to the reference point position. The reference point is actually the base‚ so there is no compensation No. Set the number that is decremented by 1.
4004 mdvno Division point number at the most negative side
Set the compensation data No. that is on the farthest negative side.
4005 pdvno Division point number at the most positive side
Set the compensation data No. that is on the farthest positive side.
4006 sc Compensation scale factor
Set the compensation amount’s scale. When the compensation scale is set to “1”, the compensation amount unit will be the same as the output unit.
Compensation amount unit = unit of output × compensation scale
4007 spcdv Division interval Set the interval to divide the basic axis. Each compensation data will be the compensation amount for each of these intervals.
1 to 9999999(µm)

Set the parameters corresponding to the 1st axis’ parameters 4001 to 4007 for each axis. A maximum of 6 axes can be controlled‚ but as the relative position is compensated‚ settings for 10 axes can be made.

# Item Details Setting range 4101 y y y 5124
Set the compensation amount for each axis.
–128 to 127 The actual compensation amount will be the value obtained by multiplying the setting value with the compensation scale.

Compensation data can be set according to either absolute or incremental system. "#4000:Pinc" 0: Absolute system 1: Incremental system (1) Absolute system
Feed from the reference point to each division point is executed as shown in the following figure. The following is obtained at this time. Set it as the compensation amount.
(Specified position – Real machine position) × 2 (Unit of output) For example‚ assume that the feed from the reference point to the +100mm position is executed. Also‚ assume that the real machine position is 99.990mm. In this case‚ the following value is defined as the compensation amount used at the +100mm position:
(100000 – 99990) × 2 = 20 pulses The resultant value is defined as the compensation amount. Assume that the real machine position resulting when feed to the –100mm position is executed‚ is –99.990mm. In this case‚ the following value is defined as the compensation amount used at the –100mm position:
(–100000 – (–99990)) × 2 = –20 pulses


The following figure (left) contains a machine position that is placed in the positive direction with respect to the reference point. Assume that feed from division n–1 to n (division interval) is executed. In this case‚ the following value is defined as the compensation amount:
(Division interval – Actual movement distance) × 2 (Unit of output) The following figure (right) contains a machine position that is placed in the negative direction with respect to the reference point. Assume that feed from division point n+1 to n by the division interval is executed. In this case‚ the following value is defined as the compensation amount:
(Division interval + Actual movement distance) × 2 (Unit of output)

n: Division point compensation number 1: Division interval
(Note) The unit of output is used as the unit of setting. The actual unit of compensation pulses depends
on the compensation scale factor.
(2) Incremental system

(1) When "mdvno" or "pdvno" exists at both ends of "rdvno":

Division point number #4101 #4102 #4103 #4104 #4105 #4106 rdvno 4103 Specified machine position −300.000 −200.000 −100.000 100.000 200.000 300.000 mdvno 4101
Real machine position −299.999 −200.000 −100.003 100.002 200.002 299.999 pdvno 4106
Compensation Incremental 2 6 −6 −4 0 6 sc 1
amount Absolute −2 0 6 −4 −4 2 spcdv 100000 If the setting range (mdvno to "pdvno") is exceeded‚ the compensation will be based on compensation amount at mdvno or "pdvno". (2) When the range compensated is only the positive range:

Division point number #4113 #4114 #4115 #4116 #4117 rdvno 4112 Compensation Incremental −4 2 0 6 2 mdvno 4113
amount Absolute −4 −2 −2 4 6 pdvno 4117 If the machine position exceeds "pdvno"‚ the compensation will be based on the compensation amount at "pdvno". If the machine position is negative in this case‚ no compensation will be executed.

(3) When the range compensated is only the negative range:

Division point number #4125 #4126 #4127 #4128 #4129 #4130 rdvno 4130 Compensation Incremental −2 2 6 2 0 −6 mdvno 4125
amount Absolute −2 −4 −2 4 6 6 pdvno 4130 If the machine position exceeds "mdvno"‚ the compensation will be based on compensation amount at "mdvno". (4) When compensation is executed in a range that contains no reference point:

Division point number #4135 #4136 #4137 #4138 #4139 #4140 rdvno 4134 Compensation Incremental −2 −2 6 2 mdvno 4136
amount Absolute −2 −4 2 4 pdvno 4140 In this case‚ the compensation is executed in the range from "mdvno" to "pdvno". This setting rule applies also when the compensation is executed in a range which contains negative machine positions and no reference point.


Division point number #4123 #4124 #4125 #4126 #4127 #4128 rdvno 4122 Compensation Incremental −4 2 0 6 2 −6 mdvno 4123
amount Absolute −4 −2 −2 4 6 0 pdvno 4128
In this case‚ the sum of the compensation amounts set according to the incremental system is always 0. For the absolute system‚ the compensation amount at the terminal point (360 degrees) is always 0.
Error · 360°

(SETUP PARAM 6. 1/6) to (SETUP PARAM 6. 2/6)
# PLC device Item Details Setting range
10ms adding timer
Set the time for the timer used in the PLC program (ladder). (Note) This setting value is valid when
0 to 32767 (×10ms)
parameter "#6449 bit0" in the following "[BIT SELECT]" is set to "0".
100ms adding timer
Set the time for the timer used in the PLC program (ladder). (Note) This setting value is valid when
0 to 32767 (×100ms)
parameter "#6449 bit0" in the following "[BIT SELECT]" is set to "0".
100ms cumulative timer
Set the time for the timer used in the PLC program (ladder). (Note) This setting value is valid when
0 to 32767 (×100ms)
parameter "#6449 bit0" in the following "[BIT SELECT]" is set to "0".
(SETUP PARAM 6. 3/6)
# PLC device Item Details Setting range 6200 6223
Counter Set the time for the counter used in the PLC program (ladder). (Note) This setting value is valid when
parameter "#6449 bit1" in the following "[BIT SELECT]" is set to "0".
6000 6015 · 6016 6095 · 6096 6103

(SETUP PARAM 6. 4/6)
# PLC device Item Details Setting range 6301 6348
PLC constant Set the value to be set in the data type R register used in the PLC program (ladder). Even if the data is set in the R register that corresponds to the PLC side when this parameter is displayed‚ the screen will not change. Enter a different screen once‚ and then select this screen again. Note that some parameters have limited uses.
6325 Check timer of input signal for safety 6326 Check timer of output signal for safety
Reserved for the system. Used for only C64T.
0 to 32767(X100ms) Standard: 2 Set “0” for C6/C64.
–99999999

(SETUP PARAM 6. 5/6) to (SETUP PARAM 6. 6/6)
# PLC device Item Details Setting range 6401 6402 6495 6496
R4600-Low R4600-High R4647-Low R4647-High
Bit selection This is the bit type parameter used in the PLC program (ladder). Even if the data is set in the R register that corresponds to the PLC side when this parameter is displayed‚ the screen will not change. Enter a different screen once‚ and then select this screen again. Note that some parameters have limited uses.
6413 bit0 Dual monitoring interruption
Reserved for the system. Used for only C64T.
bit6 Communication terminal overheat detected
Designate whether to detect the communication terminal overheat alarm or not. 0: Detects the overheat alarm. 1: Does not detect the overheat alarm.
bit7 Control unit overheat detected
Designate whether to detect the control unit overheat alarm or not. 0: Detects the overheat alarm. 1: Does not detect the overheat alarm.
bit0 Macro interface for respective part systems
Designate whether to use the macro interface for respective part systems or not.
bit0,1 High-speed input specification
bit0: High-speed input from R54. bit1: High-speed input from R55. Note that this is used for only C64T.
bit0,1 High-speed output specification
bit0: High-speed output to R56 bit1: High-speed output to R57 Note that this is used for only C64T.
When setting the parameter (#6449/bit6,7) not to check the overheat, the control unit and
the communication terminal may not be controlled because of overheat. In such case, axis runaway may cause a machine breakage, an accident resulting in injury or death, or device breakage. To prevent the serious results, ordinarily set the parameters so that the overheat check is valid.
0/1


name 7 6 5 4 3 2 1 0
R2925 L - F0 screen
R2927 L -
R2927 H -
(Note 1) Be sure to set the bits indicated - and blanks to 0. (Note 2) Parameters #6481 to #6496 are reserved for debugging by Mitsubishi. (Note 3) High-speed input specification is valid for only the devices allocated to remote I/O. As for
the devices allocated to the input signals from network such as HR863 Q-bus bridge or H865 CC-Link, high-speed input specification is not applied to. (Note 4) When using C64T system, these parameters are used as follows;

bit1 High-speed input specification from R55. bit0 High-speed output specification to R56. #6458


name 7 6 5 4 3 2 1 0
0 #6465 R2932 L -
1 #6466 R2932 H -
2 #6467 R2933 L -
6 #6471 R2935 L -
7 #6472 R2935 H -
(Note 1) Be sure to set the bits indicated - and blanks to 0. (Note 2) Parameters #6481 to #6496 are reserved for debugging by Mitsubishi.

# Item Details Setting range (unit) 7001 to 7091
M [01] to M [10]
Set the M code used for calling out the macro with the M command. This is valid when "#1195 Mmac" is set to 1.
Set the macro call out type.
0 M98 P∆∆∆∆; and equivalent value call 1 G65 P∆∆∆∆; and equivalent value call 2 G66 P∆∆∆∆; and equivalent value call 3 G66.1 P∆∆∆∆; and equivalent value call others M98 P∆∆∆∆; and equivalent value call
Set the No. of the program to be called out.
M2mac Set the type and program No. for when calling out the macro with the 2nd miscellaneous command. The macro will be called out with the "#1170 M2name" address command when "#1198 M2mac" is set to 1. 7102 Same as the M call macro.
7103 Same as the M call macro.
G [01] to G [10]
Set the G code to be used when calling the macro with a G command. Do not set a G code used in the system.
Same as the M call macro.
Same as the M call macro.
Smac Set the type and program No. for when calling the macro with an S command. This is valid when "#1196 Smac" is set to 1. 7302 Same as the M call macro.
7303 Same as the M call macro.
Tmac Set the type and program No. for when calling the macro with a T command. This is valid when "#1197 Tmac" is set to 1. 7312 Same as the M call macro.
7313 Same as the M call macro.
27000 Nmac Not used. 0 27001 to 27071
N [0] to N [08]
Not used.
Not used.

The position switch (PSW) is used as an imaginary dog switch by assigning an axis name and coordinate values that indicate the imaginary dog position to be used instead of the dog switch on the machine axis. When the machine reaches the imaginary dog position, a signal is output to the PLC interface. This imaginary dog switch is called the position switch (PSW).
No. Item Details Setting range (unit) 7500 Pcheck High-speed switching of position switch
Specify whether to perform position switch area checking at high speeds. 0: Does not perform position switch area checking at high speed (do it the same as before). 1: Performs position switch area checking at high speed.
75∗1 Axis name Specify the name of the axis for which a position switch is provided.
X, Y, Z, U, V, W, A, B, or C axis address
75∗2 Imaginary dog position 1
When the machine enters the range between imaginary dog positions 1 and 2, a signal is output to the PLC.
−99999.999
(0.001mm)
75∗3 Imaginary dog position 2
Part system 1 device X 660 Part system 2 device Y 6E0
75∗4 Selection of area check method
When position switch area checking at high speed is selected, specify the mode of area checking, i.e., whether to use the command type machine position or detector feedback position, for each position switch point. 0: Use the command type machine position as the machine position for position switch area checking. 1: Use the detector feedback position as the machine position for position switch area checking. (Note) This parameter is valid only
when 1 set in “#7500 Pcheck.”
0/1 · 0/1

Position switch numbers of PSW1 to PSW16 and signal devices
1st part system
PSW1 7501 7502 7503 X660 X6E0 X760 X7E0 X860 X8E0 X960 PSW2 7511 7512 7513 X661 X6E1 X761 X7E1 X861 X8E1 X961 PSW3 7521 7522 7523 X662 X6E2 X762 X7E2 X862 X8E2 X962 PSW4 7531 7532 7533 X663 X6E3 X763 X7E3 X863 X8E3 X963 PSW5 7541 7542 7543 X664 X6E4 X764 X7E4 X864 X8E4 X964 PSW6 7551 7552 7553 X665 X6E5 X765 X7E5 X865 X8E5 X965 PSW7 7561 7562 7563 X666 X6E6 X766 X7E6 X866 X8E6 X966 PSW8 7571 7572 7573 X667 X6E7 X767 X7E7 X867 X8E7 X967 PSW9 7581 7582 7583 X670 X6F0 X770 X7F0 X870 X8F0 X970 PSW10 7591 7592 7593 X671 X6F1 X771 X7F1 X871 X8F1 X971 PSW11 7601 7602 7603 X672 X6F2 X772 X7F2 X872 X8F2 X972 PSW12 7611 7612 7613 X673 X6F3 X773 X7F3 X873 X8F3 X973 PSW13 7621 7622 7623 X674 X6F4 X774 X7F4 X874 X8F4 X974 PSW14 7631 7632 7633 X675 X6F5 X775 X7F5 X875 X8F5 X975 PSW15 7641 7642 7643 X676 X6F6 X776 X7F6 X876 X8F6 X976 PSW16 7651 7652 7653 X677 X6F7 X777 X7F7 X877 X8F7 X977
Instead of the dog switch provided on the machine axis‚ the coordinate values indicating imaginary dog positions (dog1 and dog2) on the coordinate axis of the axis name preset with axis are set with the position switches (PSW1 – PSW16). When the machine reaches the position‚ the signal is output to the device corresponding to the PLC interface. Example of settings of dog1 and dog2 and operation

If dog1 equals dog2‚ the dog1 position triggers a signal.

Setting of dog1 and dog2 Operation Description

A signal is output between dog1 and dog2.

A signal is also output when dog1 is negative.

A signal is output between dog2 and dog1.
⏐dog1 − dog2⏐ ≥ 360

A signal is kept output when the difference between dog1 and dog2 exceeds 360 degrees.
To cancel the position switch‚ enter the number (#75∗1) of the position switch to be canceled in # ( ) of the setting area‚ enter a slash "/" in DATA ( )‚ then press the INPUT key. This deletes the axis name for the specified position switch‚ thus invalidating the position switch. The data specified for and are still stored in memory. To validate the position switch again‚ therefore‚ it is enough to specify the axis name only.
Rotary axis · dog1 < dog2 · dog1 > dog2

(Note) These parameters are used only with the G64T.
# Item Details Setting range
METHOD Select the index command method.
26252 AUX bit0 Select the rotary axis' control method.
0 to F Set as a HEX value.
bit1 Validates addition/subtraction with the index position command input.
26253 JOG CLAMP SPEED 1 Set JOG speed 1 or indexing speed clamp 1. 26254 JOG CLAMP SPEED 2 Set JOG speed 2 or indexing speed clamp 2. 26255 JOG CLAMP SPEED 3 Set JOG speed 3 or indexing speed clamp 3.
1 to 1000000 (mm/min, °/min)
(unit) 26251 · 0/1/2/3

# Item Details Setting range
(unit) 26256 CURRENT LIMIT Set current limit value when current limit value command signal is ON.
26257 OFFSET Set the indexing position compensation amount. -999.999 to 999.999 (mm) 26258 OFFSET LIMIT If the indexing position compensation amount exceeds this value, the "index position offset MAX reached" signal (M:Y18E, L:Y100) will be output.
0 to 999.999 (mm)
26259 DETECTION WIDTH Set the tolerable width for outputting the in-position signal when indexing is completed.
0 to 999.999 (mm) 26260 CURRENT LIMIT 2 Set current limit value when current limit value command 2 signal is ON.
26261 CURRENT LIMIT 3 Set current limit value when current limit value command 3 signal is ON.

(Note) These parameters are used only with the G64T. The position switch (PSW) is used as an imaginary dog switch by assigning an axis name and coordinate values that indicate the imaginary dog position to be used instead of the dog switch on the machine axis. When the machine reaches the imaginary dog position, a signal is output to the PLC interface. This imaginary dog switch is called the position switch (PSW). The position switch for the indexing axis is set on this screen.

The PLC position output signal turns ON when the machine reaches the range between the imaginary dog position 1 and imaginary dog position 2.
Position switch numbers of PSW1 to PSW16 and signal devices
<dog1> <dog2> 1st axis device
PSW1 27701 27702 R3561/bit0 R3566/bit0 R3571/bit0 R3576/bit0 PSW2 27703 27704 R3561/bit1 R3566/bit1 R3571/bit1 R3576/bit1 PSW3 27705 27706 R3561/bit2 R3566/bit2 R3571/bit2 R3576/bit2 PSW4 27707 27708 R3561/bit3 R3566/bit3 R3571/bit3 R3576/bit3 PSW5 27709 27710 R3561/bit4 R3566/bit4 R3571/bit4 R3576/bit4 PSW6 27711 27712 R3561/bit5 R3566/bit5 R3571/bit5 R3576/bit5 PSW7 27713 27714 R3561/bit6 R3566/bit6 R3571/bit6 R3576/bit6 PSW8 27715 27716 R3561/bit7 R3566/bit7 R3571/bit7 R3576/bit7 PSW9 27717 27718 R3561/bit8 R3566/bit8 R3571/bit8 R3576/bit8 PSW10 27719 27720 R3561/bit9 R3566/bit9 R3571/bit9 R3576/bit9 PSW11 27721 27722 R3561/bitA R3566/bitA R3571/bitA R3576/bitA PSW12 27723 27724 R3561/bitB R3566/bitB R3571/bitB R3576/bitB PSW13 27725 27726 R3561/bitC R3566/bitC R3571/bitC R3576/bitC PSW14 27727 27728 R3561/bitD R3566/bitD R3571/bitD R3576/bitD PSW15 27729 27730 R3561/bitE R3566/bitE R3571/bitE R3576/bitE PSW16 27731 27732 R3561/bitF R3566/bitF R3571/bitF R3576/bitF
(Note) If the imaginary dog positions 1 and 2 are both set to “0”, the signal will not be output to the PLC
interface.
2nd axis device · 3rd axis device · 4th axis device

(Note) These parameters are used only with the G64T.
Item Details Setting range (unit) POSITION Command the indexing position. –99999.999 to 99999.999
(0.001mm/0.001°,
0.0001mm/0.0001°) SPEED Set the indexing speed. 0 to 999999 (mm/min, °/min) INPOS Set the in-position width, which indicates the output range of the in-position signal output when positioning is completed.
0 to 99999.999 (0.001mm/0.001°,
0.0001mm/0.0001°) FLAG 0: Normal indexing position command 1: Position command valid for external positioning 2: Indexing command compensation valid
100 sets can be set for each axis. When changing the axis, set the axis No. after "X" in the first setting area, such as # (X2), and then press INPUT. Axis No. "1" corresponds to the 1st peripheral axis. (Example 1) To change to 2nd peripheral axis # ( X2) INPUT (Example 2) To change to 4th peripheral axis # ( X4) INPUT
0/1/2

No. Name Details Setting range Default
MSR Motor series Set the motor series. This is automatically judged by the system when the default value (0000) is set.
0000 to FFFF (hexadecimal)
RTY Regeneration option type
Set the regenerative resistor type. Do not set values without a description.
0 (Default value)
0 Amplifier standard built-in resistor (10CT has no built-in resistor) 1 Setting prohibited 2 MR-RB032 (30W) 3 MR-RB12 (100W) 4 MR-RB32 (300W) 5 MR-RB30 (300W) 6 MR-RB50 (500W) 7~F
PC1 Motor side gear ratio (machine rotation ratio)
Set the No. of gear teeth on the motor side and the No. of gear teeth on the machine side as an integer reduced to its lowest terms. Set the total gear ratio if there are multiple gear levels. For rotation axes, set the No. of motor rotation speed per machine rotation.
PC2 Machine side gear ratio (motor rotation ratio)
PIT Feed pitch Set 360 (default value) for rotation axes. Set the feed lead for linear axes.
1 to 32767 (° or mm)
6 INP In-position detection width
In-position is detected when the position droop becomes this setting value or less.
1 to 32767 (1/1000° or µm)
value · Setting · value Details

No. Name Details Setting range Default
7 ATU Auto-tuning Set the adjustment of the auto-tuning. Do not set values without a description.
0 1 0 2 (Default setting value)
1 Low response (low-rigidity loads, loads which easily vibrate) 2 Standard setting value 3 Standard setting value 4 Standard setting value
5 High response (high-rigidity loads, loads which do not easily vibrate)
2 Large friction amount (set the position loop gain slightly lower)
0 Only auto-tuning PG2, VG2, VIC, and GD2.
1 Auto-tuning PG1, PG2, VG1, VG2, VIC, and GD2 (total gain). (Standard setting) 2 No auto-tuning.
8 PG1 Position loop gain 1
Set the position loop gain for the model loop. Determine the tracking ability regarding the position commands.
4 to 1000 (1/s) 70
(Not used.) 0
10 EMGt Deceleration control time constant
Set the deceleration time from the clamp speed (Aspeed1). For normal rapid traverse, set the same value as the acceleration/deceleration time constant.
0 to 32768 (ms) 500
(Not used.) 0
(Not used.) 0
13 MBR Vertical axis drop prevention time
Input the time the servo OFF is delayed during servo OFF command. Increase the setting by 100ms at a time and set the minimum value where the axis does not drop.
0 to 1000 (ms) 100

No. Name Details Setting range Default
14 NCH Notch filter No. Set the frequency of the machine resonance suppression filter.
Do not set values without a description.
value 0 1 2 3 4 5 6 7
No start 1125 563 375 282 225 188 161
(Not used.) 0
16 JIT Jitter compensation
Set the No. of ignored jitter compensation pulses. Do not set values without a description.
Setting value 0 1 2 3 Number of ignore
pulses No start 1 2 3
(Not used.) 0
(Not used.) 0
19 PG2 Position loop gain 2
Set the position loop gain of the actual loop. Determine the position responsiveness for external disturbance.
1 to 500 (1/s) 25
20 VG1 Speed loop gain 1
Set the speed loop gain of the model loop. Determine the tracking ability regarding the speed commands.
20 to 5000 (1/s) 1200
21 VG2 Speed loop gain 2
Set the speed loop gain of the actual loop. Determine the speed responsiveness for external disturbance.
20 to 8000 (1/s) 600
22 VIC Speed integral compensation
Determine the characteristics of the speed low-frequency region.
1 to 1000 (ms) 20
23 VDC Speed differential compensation
PI control normally results from a default value of 1000. Adjust the overshoot amount by lowering in increments of 20.
DG2 Load inertia ratio
Set the load inertia ratio for the motor inertia. 0.0 to 50.0 (fold)
(Not used.) 0
MTY Motor type Set the motor type. This is automatically judged by the system when the default value (0000) is set.
0000 to FFFF (hexadecimal)


Set the Nos. of the data to be output on D/A output channel 1.
Set this value when the zero level of D/A output channel 1 is not suitable.
Set the Nos. of the data to be output on D/A output channel 2. The descriptions are the same as "50 MD1".
Set this value when the zero level of D/A output channel 2 is not suitable.
Set the No. of stations. For linear axes, this value is expressed by: No. of divisions = No. of stations – 1.


This is a HEX setting parameter. Set bits without a description to their default values.
bit F E D C B A 9 8 7 6 5 4 3 2 1 0
value 0 1 0
bit Meaning when "0" is set Meaning when "1" is set 0
1 High-speed zero point return after establishment of zero point.
Dog-type return for each zero point return operation. 2 3 4 5 6 7
9 Rotation direction determined by operation control signal (DIR)
Electrical zero point becomes the origin point B C
Rotation direction in operation control signal (DIR) or in the shortcut direction
Rotation direction in the random position command sign direction
Stopper direction is in the sign direction of the stopper amount

No. Name Details Setting range Default
Cont2 Control parameter 2
This is a HEX setting parameter. Set bits without a description to their default values.
bit F E D C B A 9 8 7 6 5 4 3 2 1 0
value 0 1 0 1 1 0
bit Meaning when "0" is set Meaning when "1" is set 0 1 Error not corrected at servo OFF Error corrected at servo OFF 2 Linear axis Rotation axis 3 Station assignment direction CW Station assignment direction CCW 4 Uniform index Non-uniform index 5 DO channel standard assignment DO channel reverse assignment 6 2-wire detector communication 4-wire detector communication 7 Incremental detection Absolute position detection 8 9 A B C D E F
This is a HEX setting parameter. Set bits without a description to their default values.
bit F E D C B A 9 8 7 6 5 4 3 2 1 0
value 0 1
bit Meaning when "0" is set Meaning when "1" is set
0 External emergency stop valid External emergency stop invalid (default value)
1 Dynamic brake stop at emergency stop
Deceleration control stop at emergency stop
2 NC bus emergency stop input valid
NC bus emergency stop input invalid
NC bus emergency stop output invalid 4 5 6 7 8 9 A B C D E F
3 NC bus emergency stop output valid

No. Name Details Setting range Default
tleng Linear axis stroke length
Set the movement stroke length for linear axes. This is meaningless when setting non-uniform assignments or commanding random positions.
0.001 to 99999.999 (mm)
100.000
110 ZRNspeed Reference point return speed
Set the clamp value of the feedrate when a reference point return is carried out. The feedrate becomes the manual operation speed of the parameter group selected at that time, but it is clamped by this parameter setting value.
1 to 100000 (°/min or mm/min)
111 ZRNcreep Reference point return creep speed
Set the approach speed to the reference point after dog detection during a reference point return.
1 to 65535 (°/min or mm/min)
112 grid mask Grid mask Set the amount that the dog is artificially extended. Set 1/2 the grid spacing as a standard.
0 to 65536 (1/1000° or µm)
Divide the grid spacing that is the conventional motor rotation movement amount into 2, 4, 8, or 16 divisions.
0 to 4 (1/2n division)
114 ZRNshift Reference point shift amount
Set the shift amount in a dog-type reference point return from the electric zero point determined on the grid to the reference point.
0 to 65536 (1/1000° or µm)
115 ST. ofset Station offset
Set the distance (offset) from the reference point to station 1.
–99999.999 to 99999.999 (° or mm)
When movement of the machine coordinate zero point from the origin point is required during absolute position initializing, set that movement amount.
–99999.999 to 99999.999 (° or mm)
117 Limit (+) Soft limit (+) Commands in the plus direction that exceed this
–99999.999 to 99999.999 (mm)
setting value are not possible. If the machine is in a position exceeding the setting value, commands in the minus direction are possible. The soft limit function will not operate if Limit (+) and Limit (–) are set to the same value.
118 Limit (–) Soft limit (–) Commands in the minus direction that exceed this
–99999.999 to 99999.999 (mm)
value are not possible. If the machine is in a position exceeding the setting value, commands in the plus direction are possible.

No. Name Details Setting range Default
120 ABS Type Absolute position detection parameter
This parameter is set as a hexadecimal. Set the default value for bits that have no description.
bit F E D C B A 9 8 7 6 5 4 3 2 1 0
value 0 1 0 0
bit Meaning when "0" is set Meaning when "1" is set 0 1 Dogless-type method initializing Dog-type method initializing
Origin point alignment method initializing 3 Electrical zero point direction (+) Electrical zero point direction (–) 4 5 6 7 8 9 A B C D E F
2 Mechanical stopper method initializing
Absolute position power OFF tolerable movement value
Set the value for the tolerable amount of movement for a machine that moved during power OFF in an absolute position detection system. The "Absolute position power OFF movement exceeded (ABS)" signal will turn ON if the machine moves more than this setting value during power OFF. The movement amount is not checked when this parameter is set to 0.000.
0.000 to 99999.999 (° or mm)
130 backlash Backlash compensa- tion amount
Set the backlash compensation amount. 0 to 9999 (1/1000° or µm)
(Not used.) 0
(Not used.) 0
(Not used.) 0
(Not used.) 0
value · Default · 123 ABS check

< Operation parameter group 1 >
No. Name Details Setting range Default
150 Aspeed1 Operation parameter group 1 Automatic operation speed
Set the feedrate during automatic operation when operation parameter group 1 is selected. This parameter is regarded as the clamp value for the automatic operation speeds and manual operation speeds of all operation groups. A speed exceeding Aspeed1 cannot be commanded, even if set in the parameters.
1 to 100000 (°/min or mm/min)
151 Mspeed1 Operation parameter group 1 Manual operation speed
Set the feedrate during manual operation or JOG operation when operation parameter group 1 is selected.
1 to 100000 (°/min or mm/min)
152 time1.1 Operation parameter group 1 Acceleration/ deceleration time constant 1
Set the linear acceleration/deceleration time for Aspeed 1(the operation parameter group 1 automatic operation speed (clamp speed)) when operation parameter group 1 is selected. When operating at speeds less than the clamp speed, the axis will linearly accelerate/decelerate at the inclination determined above. When this is set together with acceleration/deceleration time constant 2, S-shape acceleration/deceleration is carried out. In this case, set the acceleration/deceleration time of the linear part in this parameter.
1 to 9999 (ms) 100
153 time1.2 Operation parameter group 1 Acceleration/ deceleration time constant 2
Set this parameter when carrying out S-shape acceleration/deceleration. When S-shape acceleration/deceleration is carried out, set the total time of the non-linear parts. When "1" is set in this parameter, linear acceleration/deceleration is carried out. In the handle feed operation mode, this set value is regarded as the time constant for the linear acceleration/deceleration.
1 to 999 (ms) 1
value

No. Name Details Setting range Default
154 TL1 Operation parameter group 1 Torque limit value
Set the motor output torque limit value when operation parameter group 1 is selected. At the default value, the torque is limited at the maximum torque of the motor specifications. Set the default value when torque limit is not especially required. In the stopper positioning operation mode, this becomes the torque limit value when positioning to the stopper starting coordinates.
155 OD1 Operation parameter group 1 Excessive error detection width
Set the excessive error detection width when operation parameter group 1 is selected. An alarm of excessive error (S03 0052) is detected when the position droop becomes larger than this setting value. In the stopper positioning operation mode, this becomes the excessive error detection width when positioning to the stopper starting coordinates.
0 to 32767 (° or mm)
156 just1 Operation parameter group 1 Set position output width
The signal indicating that the machine position is at any one of the stations is the set position reached (JST) signal. During automatic operation, the automatic set position reached (JSTA) signal is also output under the same conditions. Set the tolerable values at which these signals are output when operation parameter group 1 is selected. These signals turn OFF when the machine position is separated from the station by more than this value.
0.000 to 99999.999 (° or mm)
157 near1 Operation parameter group 1 Near set position output width
The signal indicating that the machine position is near any one of the station positions is the near set position (NEAR) signal. Set the tolerable value at which this signal is output when operation parameter group 1 is selected. This value is generally set wider than the set position output width. During operations, this is related to special commands when the station selection is "0".
0.000 to 99999.999 (° or mm)
value

< Operation parameter group 2 >
No. Name Details Setting range Default
158 Aspeed2 Operation parameter group 2 Automatic operation speed
Set the feedrate during automatic operation when operation parameter group 2 is selected.
1 to 100000 (°/min or mm/min)
159 Mspeed2 Operation parameter group 2 Manual operation speed
Set the feedrate during manual operation or JOG operation when operation parameter group 2 is selected.
1 to 100000 (°/min or mm/min)
160 time2.1 Operation parameter group 2 Acceleration/ deceleration time constant 1
Set the linear acceleration/deceleration time for the operation parameter group 1 automatic operation speed (clamp speed) when operation parameter group 2 is selected. When operating at speeds less than the clamp speed, the axis will linearly accelerate/decelerate at the inclination determined above. When this is set together with acceleration/deceleration time constant 2, S-shape acceleration/deceleration is carried out. In this case, set the acceleration/deceleration time of the linear part in this parameter.
1 to 9999 (ms) 100
161 time2.2 Operation parameter group 2 Acceleration/ deceleration time constant 2
Set this parameter when carrying out S-shape acceleration/deceleration. When S-shape acceleration/deceleration is carried out, set the total time of the non-linear parts. When 1 is set in this parameter, linear acceleration/deceleration is carried out. In the handle feed operation mode, this set value is regarded as the time constant for the linear acceleration/deceleration.
1 to 9999 (ms) 1
value

No. Name Details Setting range Default
162 TL2 Operation parameter group 2 Torque limit value
Set the motor output torque limit value when operation parameter group 2 is selected. At the default value, the torque is limited at the maximum torque of the motor specifications. Set the default value when torque limit is not especially required. In the stopper positioning operation mode, this becomes the torque limit value during stopper operation.
163 OD2 Operation parameter group 2 Excessive error detection width
Set the excessive error detection width when operation parameter group 2 is selected. An excessive error alarm (S03 0052) is detected when the position droop becomes larger than this setting value. In the stopper positioning operation mode, this becomes the excessive error detection width during stopper operation.
0 to 32767 (° or mm)
164 just2 Operation parameter group 2 Set position output width
The signal indicating that the machine position is at any one of the stations is the set position reached (JST) signal. During automatic operation, the automatic set position reached (JSTA) signal is also output under the same conditions. Set the tolerable values at which these signals are output when operation parameter group 2 is selected. These signals turn OFF when the machine position is separated from the station by more than this value.
0.000 to 99999.999 (° or mm)
165 near2 Operation parameter group 2 Near set position output width
The signal indicating that the machine position is near any one of the station positions is the near set position (NEAR) signal. Set the tolerable values at which these signals are output when operation parameter group 2 is selected. These values are generally set wider than the set position output width. During operations, this is related to special commands when the station selection is “0”.
0.000 to 99999.999 (° or mm)
value

< Operation parameter group 3 >
No. Name Details Setting range Default
166 Aspeed3 Operation parameter group 3 Automatic operation speed
Set the feedrate during automatic operation when operation parameter group 3 is selected.
1 to 100000 (°/min or mm/min)
167 Mspeed3 Operation parameter group 3 Manual operation speed
Set the feedrate during manual operation or JOG operation when operation parameter group 3 is selected.
1 to 100000 (°/min or mm/min)
168 time3.1 Operation parameter group 3 Acceleration/ deceleration time constant 1
Set the linear acceleration/deceleration time for the operation parameter group 1 automatic operation speed (clamp speed) when operation parameter group 3 is selected. When operating at speeds less than the clamp speed, the axis will linearly accelerate/decelerate at the inclination determined above. When this is set together with acceleration/deceleration time constant 2, S-shape acceleration/deceleration is carried out. In this case, set the acceleration/deceleration time of the linear part in this parameter.
1 to 9999 (ms) 100
169 time3.2 Operation parameter group 3 Acceleration/ deceleration time constant 2
Set this parameter when carrying out S-shape acceleration/deceleration. When S-shape acceleration/deceleration is carried out, set the total time of the non-linear parts. When 1 is set in this parameter, linear acceleration/deceleration is carried out. In the handle feed operation mode, this set value is regarded as the time constant for the linear acceleration/deceleration
1 to 9999 (ms) 1
value

No. Name Details Setting range Default
170 TL3 Operation parameter group 3 Torque limit value
Set the motor output torque limit value when operation parameter group 3 is selected. At the default value, the torque is limited at the maximum torque of the motor specifications. Set the default value when torque limit is not especially required. In the stopper positioning operation mode, this becomes the pressing torque limit value after completion of the positioning.
171 OD3 Operation parameter group 3 Excessive error detection width
Set the excessive error detection width when operation parameter group 3 is selected. An excessive error alarm (S03 0052) is detected when the position droop becomes larger than this setting value. In the stopper positioning operation mode, this becomes the excessive error detection width during pressing after completion of the positioning.
0 to 32767 (° or mm)
172 just3 Operation parameter group 3 Set position output width
The signal indicating that the machine position is at any one of the stations is the set position reached (JST) signal. During automatic operation, the automatic set position reached (JSTA) signal is also output under the same conditions. Set the tolerable values at which these signals are output when operation parameter group 3 is selected. These signals turn OFF when the machine position is separated from the station by more than this value.
0.000 to 99999.999 (° or mm)
173 near3 Operation parameter group 3 Near set position output width
The signal indicating that the machine position is near any one of the station positions is the near set position (NEAR) signal. Set the tolerable values at which these signals are output when operation parameter group 3 is selected. These values are generally set wider than the set position output width. During operations, this is related to special commands when the station selection is “0”.
0.000 to 99999.999 (° or mm)
value

< Operation parameter group 4 >
No. Name Details Setting range Default
174 Aspeed4 Operation parameter group 4 Automatic operation speed
Set the feedrate during automatic operation when operation parameter group 4 is selected.
1 to 100000 (°/min or mm/min)
175 Mspeed4 Operation parameter group 4 Manual operation speed
Set the feedrate during manual operation or JOG operation when operation parameter group 4 is selected.
1 to 100000 (°/min or mm/min)
176 time4.1 Operation parameter group 4 Acceleration/ deceleration time constant 1
Set the linear acceleration/deceleration time for the operation parameter group 1 automatic operation speed (clamp speed) when operation parameter group 4 is selected. When operating at speeds less than the clamp speed, the axis will linearly accelerate/decelerate at the inclination determined above. When this is set together with acceleration/deceleration time constant 2, S-shape acceleration/deceleration is carried out. In this case, set the acceleration/deceleration time of the linear part in this parameter.
1 to 9999 (ms) 100
177 time4.2 Operation parameter group 4 Acceleration/ deceleration time constant 2
Set this parameter when carrying out S-shape acceleration/deceleration. When S-shape acceleration/deceleration is carried out, set the total time of the non-linear parts. When 1 is set in this parameter, linear acceleration/deceleration is carried out. In the handle feed operation mode, this set value is regarded as the time constant for the linear acceleration/deceleration.
1 to 9999 (ms) 1
value

No. Name Details Setting range Default
178 TL4 Operation parameter group 4 Torque limit value
Set the motor output torque limit value when operation parameter group 4 is selected. At the default value, the torque is limited at the maximum torque of the motor specifications. Set the default value when torque limit is not especially required. In the stopper method initializing mode in absolute position detection systems, this becomes the torque limit value during stopper operation.
179 OD4 Operation parameter group 4 Excessive error detection width
Set the excessive error detection width when operation parameter group 4 is selected. An excessive error alarm (S03 0052) is detected when the position droop becomes larger than this setting value. In the stopper method initializing mode in absolute position detection systems, this becomes the excessive error detection width during stopper operation.
0 to 32767 (° or mm)
180 just4 Operation parameter group 4 Set position output width
The signal indicating that the machine position is at any one of the stations is the set position reached (JST) signal. During automatic operation, the automatic set position reached (JSTA) signal is also output under the same conditions. Set the tolerable values at which these signals are output when operation parameter group 4 is selected. These signals turn OFF when the machine position is separated from the station by more than this value.
0.000 to 99999.999 (° or mm)
181 near4 Operation parameter group 4 Near set position output width
The signal indicating that the machine position is near any one of the station positions is the near set position (NEAR) signal. Set the tolerable values at which these signals are output when operation parameter group 4 is selected. These values are generally set wider than the set position output width. During operations, this is related to special commands when the station selection is “0”.
0.000 to 99999.999 (° or mm)
value

No. Name Details Setting range Default
190 stpos2 Station 2 coordinate value
Set the coordinate value of each station when non-uniform assignment is selected. The station 1 coordinate value is fixed at 0.000 (machine coordinate zero point).
–99999.999 to 99999.999 (° or mm)
191 stpos3 Station 3 coordinate value
192 stpos4 Station 4 coordinate value
193 stpos5 Station 5 coordinate value
194 stpos6 Station 6 coordinate value
195 stpos7 Station 7 coordinate value
196 stpos8 Station 8 coordinate value
197 stpos9 Station 9 coordinate value
200 PSWcheck PSW detection method
This is a HEX setting parameter. Set bits without a description to their default values.
bit F E D C B A 9 8 7 6 5 4 3 2 1 0
value 0
switch Meaning when "0" is set Meaning when "1" is set
0 PSW1 1 PSW2 2 PSW3 3 PSW4 4 PSW5 5 PSW6 6 PSW7 7 PSW8
The position switch output is judged by the machine position of the command system.
The position switch output is judged by the machine FB position (actual position).
value · Default · bit Position

No. Name Details Setting range Default
201 202 PSW1dog1 PSW1dog2
PSW1 area setting 1 PSW1 area setting 2
When the machine position is in the region between region settings 1 and 2, the position switch of each No. will turn ON. Whether the value of setting 1 is larger than setting 2 (vice versa) does not affect the position switch operation. For rotation axes, the output turns ON at the region without including 0.000 degree.
-99999.999 to 99999.999 (° or mm)
203 204 PSW2dog1 PSW2dog2
PSW2 area setting 1 PSW2 area setting 2
205 206 PSW3dog1 PSW3dog2
PSW3 area setting 1 PSW3 area setting 2
207 208 PSW4dog1 PSW4dog2
PSW4 area setting 1 PSW4 area setting 2
209 210 PSW5dog1 PSW5dog2
PSW5 area setting 1 PSW5 area setting 2
211 212 PSW6dog1 PSW6dog2
PSW6 area setting 1 PSW6 area setting 2
213 214 PSW7dog1 PSW7dog2
PSW7 area setting 1 PSW7 area setting 2
215 216 PSW8dog1 PSW8dog2
PSW8 area setting 1 PSW8 area setting 2
220 push Stopper amount
Set the command stroke of the stopper operation during stopper positioning operations.
0.000 to 359.999 (° or mm)
221 pusht1 Stopper standby time
Set the standby time from the stopper starting coordinate positioning to the stopper operation start during stopper positioning operations.
0 to 9999 (ms) 0
222 pusht2 Stopper torque release time
Set the time from the completion of the stopper operation to the changeover of the stopper torque during stopper positioning operations.
0 to 9999 (ms) 0
223 pusht3 Set position signal output delay time
Set the time from the completion of the stopper operation to the output of the automatic set position reached (JSTA), set position reached (JST), and near set position (NEAR) signals during stopper positioning operations.
0 to 9999 (ms) 0
value

Date of revision Manual No. Revision details
Dec. 2000 BNP-B2267* First edition created.
#1926 IP address #21025 SmpDelay
#1927 Subnet mask #21028 ed_mess
#1928 Gateway address #21029 NCname
#1929 Port number #21030 AlmHold
#21049 SPname (2) 16. Indexing axis parameters (#26251 ~ ) (3) 17. Indexing axis position switch (#27701 ~ ) (4) 18 Indexing axis commands • Mistakes, etc. were corrected.
#21031 UnitMax · #21032 UnitNum

Every effort has been made to keep up with software and hardware revisions in the contents described in this manual. However, please understand that in some unavoidable cases simultaneous revision is not possible. Please contact your Mitsubishi Electric dealer with any questions or comments regarding the use of this product.
This instruction manual may not be reproduced in any form, in part or in whole, without written permission from Mitsubishi Electric Corporation.

MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE : MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
MC6/C64/C64T
MODEL
CODE
Manual No.
Specifications subject to change without notice.
Printed in Japan on recycled paper.
008-046
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.