EN
Mitsubishi Electronics logo
Official user manual

Mitsubishi Electronics CNC Controller Board (C64)

317 pages·3 MB·Crib Toy·PDF·ENDEFRITNLJA
Mitsubishi Electronics CNC Controller Board (C64)
Table of Contents 57 sections Cover · Introduction · Precautions for Safety · CONTENTS · … ShowHide
Coverp.1Introductionp.3Precautions for Safetyp.4CONTENTSp.61. Parameter Screensp.72. Machining Parametersp.92.1 Workpiece Coordinate Offsetp.92.2 Process Parametersp.102.3 Control Parametersp.122.4 Axis Parametersp.132.5 Barrier Datap.143. I/O Parametersp.153.1 Base Parametersp.153.2 I/O Device Parametersp.164. Setup Parametersp.205. Base Specifications Parametersp.216. Axis Specifications Parametersp.726.1 Axis Specifications Parametersp.726.2 Zero Point Return Parametersp.796.3 Absolute Position Parametersp.816.4 Axis Specifications Parameters 2p.837. Servo Parametersp.867.1 MDS-B-SVJ2p.887.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)p.1147.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)p.1427.4 Supplementp.1727.4.1 D/A Output Specificationsp.1727.4.2 Electronic Gearsp.1787.4.3 Lost Motion Compensationp.1798. Spindle Parametersp.1808.1 Spindle Base Specifications Parametersp.1808.2 MDS-B-SPJ2p.1878.3 MDS-B-SP/SPH, MDS-C1-SP/SPHp.2078.4 MDS-C1-SPMp.2408.5 Supplementp.2728.5.1 D/A Output Specificationsp.2729. Machine Error Compensationp.2759.1 Function Outlinep.2759.2 Setting Compensation Datap.2799.3 Example in Using a Linear Axis as the Base Axisp.2819.4 Example in Using a Rotation Axis as the Base Axisp.28310. PLC Constantsp.28410.1 PLC Timerp.28410.2 PLC Counterp.28410.3 PLC Constantsp.28510.4 PLC Bit Selectionp.28611. Macro Listp.28912. Position Switchp.29012.1 Outline of Functionp.29012.2 Canceling the Position Switchp.29213. Indexing Axis Parametersp.29314. Indexing Axis Position Switchp.29514.1 Outline of Functionp.29515. Indexing Axis Commandsp.29616. Auxiliary Axis Parametersp.297Revision Historyp.315Back coverp.317
Page 1 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — BNP-B2267C(ENG)
Page 1 · click to enlarge
Page 1

CNC

C6/C64/C64T

PARAMETER MANUAL

Mitsubishi Electronics CNC Controller Board (C64) — CNC diagram (page 1)
Fig. 1
Mitsubishi Electronics CNC Controller Board (C64) — CNC diagram (page 1)
Fig. 2
Mitsubishi Electronics CNC Controller Board (C64) — CNC diagram (page 1)
Fig. 3
Mitsubishi Electronics CNC Controller Board (C64) — CNC diagram (page 1)
Fig. 4
Mitsubishi Electronics CNC Controller Board (C64) — CNC diagram (page 1)
Fig. 5
Mitsubishi Electronics CNC Controller Board (C64) — CNC diagram (page 1)
Fig. 6
Mitsubishi Electronics CNC Controller Board (C64) — CNC diagram (page 1)
Fig. 7
Mitsubishi Electronics CNC Controller Board (C64) — CNC diagram (page 1)
Fig. 8
Mitsubishi Electronics CNC Controller Board (C64) — CNC diagram (page 1)
Fig. 9
Mitsubishi Electronics CNC Controller Board (C64) — CNC diagram (page 1)
Fig. 10
Mitsubishi Electronics CNC Controller Board (C64) — CNC diagram (page 1)
Fig. 11
Mitsubishi Electronics CNC Controller Board (C64) — CNC diagram (page 1)
Fig. 12
Mitsubishi Electronics CNC Controller Board (C64) — CNC diagram (page 1)
Fig. 13

BNP-B2267C(ENG)

Page 2 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — Cover
Page 2 · click to enlarge
Page 2

MELDAS and MELSEC are registered trademarks of Mitsubishi Electric Corporation. Microsoft and Windows are a registered trademark of Microsoft Corporation in the United States and/or other countries. Other brands and product names throughout this manual are trademarks or registered trademarks of their respective holders.

Page 3 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — CAUTION
Page 3 · click to enlarge
Page 3

Introduction This manual is a guide of the parameters used with the CNC MELDAS C6/C64/C64T. This manual is written on the assumption that all machine parameters of the MELDAS C6/C64/C64T are provided. However, the CNC may not necessarily be provided with all of the options. When the system is used, therefore, reference should be made to the Specifications Manual issued by the machine maker. Points to be observed when reading this manual (1) This manual contains general descriptions as seen from the standpoint of NC

(numerical control) and thus refer to the Instruction Manual issued by the machine maker for descriptions of individual machine tools. The Instruction Manual issued by the machine maker takes precedence over this manual when any mention of "restrictions", "usable states" or such details are mentioned. (2) As much information as possible on special procedures has been included in this

manual, and it may be considered that any procedures not mentioned cannot be undertaken. (3) Also refer to the following manuals.

  • MELDAS C6/C64/C64T Instruction Manual........................................ BNP-B2259
  • MELDAS C6/C64/C64T Programming Manual (Machining center/Transfer machine system)........ BNP-B2260
  • MELDAS C6/C64/C64T Programming Manual (Lathe system) .......... BNP-B2264
  • MELDAS AC Servo MDS-B-Vx Series Servo Parameter Manual....... BNP-A2993
  • MELDAS AC Servo MDS-C1 Series Specification Manual................. BNP-C3000

CAUTION

For items described as "Restrictions" or "Usable State" in this manual, the Instruction

Manual issued by the machine maker takes precedence over this manual.

Items that are not described must be interpreted as "not possible".

This manual is written on the assumption that all option functions are added. Refer to the

Specifications Manual issued by the machine maker before starting use.

Refer to the manuals issued by the machine manufacturer for each machine tool

explanation.

Some screens and functions may differ or may not be usable depending on the NC system

version.

Page 4 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — CAUTION
Page 4 · click to enlarge
Page 4

Precautions for Safety Always read the Specifications Manual issued by the machine maker, this manual, related manuals and attached documents before installation, operation, programming, maintenance or inspection to ensure correct use. Understand this numerical controller, safety items and cautions before using the unit. This manual ranks the safety precautions into "DANGER", "WARNING" and "CAUTION".

When the user may be subject to imminent fatalities or major injuries if handling is mistaken. When the user may be subject to fatalities or major injuries if handling is mistaken. When the user may be subject to injuries or when physical damage may occur if handling is mistaken.

DANGER

WARNING

CAUTION

DANGER

Not applicable in this manual.

WARNING

Not applicable in this manual.

CAUTION

1. Items related to product and manual

For items described as "Restrictions" or "Usable State" in this manual, the Instruction Manual issued by the machine maker takes precedence over this manual. Items that are not described must be interpreted as "not possible". This manual is written on the assumption that all option functions are added. Refer to the Specifications Manual issued by the machine maker before starting use. Refer to the manuals issued by the machine manufacturer for each machine tool explanation. Some screens and functions may differ or may not be usable depending on the NC system version.

Page 5 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 3. Items related to the other parameters
Page 5 · click to enlarge
Page 5

CAUTION

2. Items related to servo/spindle parameters

To change the control mode to the High-gain amp (MDS-B-V14/V24) mode after

replacement of the Standard amp (MDS-B-V1/V2), it is need to change the parameters and to adjust the servo parameters to fit to the High-gain amp.

Mode change between the Standard amp mode and the High-gain amp mode is

actually performed when the power (200V) is turned ON. Thus, when changing some parameters unique to each amp, an alarm “7F” occurs and requests to turn the power ON again. Note that the alarm “7F” may occur when the amp is mounted on the machine for the first time. When the alarm “7F” occurs, turn the power ON again. The alarm “7F” may not occur at second turning ON or later unless the above-mentioned

parameters are changed.

With MDS-C1 series, only the serial encoder is applied as the motor end detector.

Thus, OHE/OHA type detector cannot be used as the motor end detector.

Do not make remarkable adjustments or changes of the parameters as the operation

may became unstable.

3. Items related to the other parameters

When setting the parameter (#6449/bit6, 7) not to check the overheat, the control unit

and the communication terminal may not be controlled because of overheat. In such case, axis runaway may cause a machine breakage, an accident resulting in injury or death, or device breakage. To prevent the serious results, ordinarily set the parameters so that the overheat check is valid.

Page 6 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — Table of Contents
Page 6 · Contents
Contents

Contents

Coverp.1Introductionp.3Precautions for Safetyp.4CONTENTSp.61. Parameter Screensp.72. Machining Parametersp.92.1 Workpiece Coordinate Offsetp.92.2 Process Parametersp.102.3 Control Parametersp.122.4 Axis Parametersp.132.5 Barrier Datap.143. I/O Parametersp.153.1 Base Parametersp.153.2 I/O Device Parametersp.164. Setup Parametersp.205. Base Specifications Parametersp.216. Axis Specifications Parametersp.726.1 Axis Specifications Parametersp.726.2 Zero Point Return Parametersp.796.3 Absolute Position Parametersp.816.4 Axis Specifications Parameters 2p.837. Servo Parametersp.867.1 MDS-B-SVJ2p.887.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)p.1147.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)p.1427.4 Supplementp.1727.4.1 D/A Output Specificationsp.1727.4.2 Electronic Gearsp.1787.4.3 Lost Motion Compensationp.1798. Spindle Parametersp.1808.1 Spindle Base Specifications Parametersp.1808.2 MDS-B-SPJ2p.1878.3 MDS-B-SP/SPH, MDS-C1-SP/SPHp.2078.4 MDS-C1-SPMp.2408.5 Supplementp.2728.5.1 D/A Output Specificationsp.2729. Machine Error Compensationp.2759.1 Function Outlinep.2759.2 Setting Compensation Datap.2799.3 Example in Using a Linear Axis as the Base Axisp.2819.4 Example in Using a Rotation Axis as the Base Axisp.28310. PLC Constantsp.28410.1 PLC Timerp.28410.2 PLC Counterp.28410.3 PLC Constantsp.28510.4 PLC Bit Selectionp.28611. Macro Listp.28912. Position Switchp.29012.1 Outline of Functionp.29012.2 Canceling the Position Switchp.29213. Indexing Axis Parametersp.29314. Indexing Axis Position Switchp.29514.1 Outline of Functionp.29515. Indexing Axis Commandsp.29616. Auxiliary Axis Parametersp.297Revision Historyp.315Back coverp.317
Page 7 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 1. Parameter Screens
Page 7 · click to enlarge
Page 7
1. Parameter Screens

1. Parameter Screens

The parameter input setting units are as follow.

Input unit "#1003 iunit"Linear axis "#1017 rot"=0Rotary axis "#1017 rot"=1 Machine constant:mm "#1040 M inch"=0 _Machine constant:inch "#1040 M inch"=1 _ B0.001 mm0.0001 inch0.001° C0.0001 mm0.00001 inch0.0001°
Mitsubishi Electronics CNC Controller Board (C64) — 1. Parameter Screens diagram (page 7)
Fig. 14 · 1. Parameter Screens
Mitsubishi Electronics CNC Controller Board (C64) — 1. Parameter Screens diagram (page 7)
Fig. 15 · 1. Parameter Screens

The following menus can be selected when the key

MenuDetailsReference Section WORKThe WORK OFFSET screen will open.2.1 Workpiece Coordinate Offset PROCESSThe PROCESS PARAM screen will open.2.2 Process Parameters 2.3 Control Parameters 2.4 Axis Parameters 2.5 Barrier Data I/O PARAMThe I/O PARAM screen will open.3.1 Base Parameters 3.2 I/O Device Parameters SETUPThe screen to set the setup parameters will open.4. Setup Parameters

(1) User parameters

Page 8 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — ALARM
Page 8 · click to enlarge
Page 8
1. Parameter Screens

The following menus can be selected when SETUP is selected. (Refer to the section "4. Setup Parameters" for details.

MenuDetailsReference Section BASEThe BASE SPEC. PARAM screen will open.5. Base Specifications Parameters AXIS SPECThe AXIS SPEC PARAM screen will open.6. Axis Specifications Parameters SERVOThe SERVO PARAM screen will open.7. Servo Parameters SPINDLEThe SPINDLE BASE SPEC. PARAM screen will open.8. Spindle Parameters MC-ERRThe MC-ERR. CMP. screen will open.9. Machine Error Compensation PLCThe PLC DATA screen will open.10. PLC Constants MACROThe MACRO FILE screen will open.11. Macro List PSWThe POSITION SWITCH screen will open.12. Position Switch IDX-PRMThe INDEXING AXIS PARAMETERS screen will open.13. Indexing Axis Parameters IDX-PSWThe INDEXING AXIS POSITION SWITCH screen will open.14. Indexing Axis Position Switch IDX-CMDThe INDEXING AXIS COMMANDS screen will open.15. Indexing Axis Commands
Mitsubishi Electronics CNC Controller Board (C64) — 1. Parameter Screens diagram (page 8)
Fig. 16 · 1. Parameter Screens

(3) The following menus can be selected when the key

ALARM

DIAGN is pressed.

MenuDetailsReference Section AUX-PRMThe AUX-PARA screen will open.16. Auxiliary Axis Parameter

(2) Setup Parameters

Page 9 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2.1 Workpiece Coordinate Offset
Page 9 · click to enlarge
Page 9
2. Machining Parameters 2.1 Workpiece Coordinate Offset

2. Machining Parameters

2.1 Workpiece Coordinate Offset

Mitsubishi Electronics CNC Controller Board (C64) — 2.1 Workpiece Coordinate Offset diagram (page 9)
Fig. 17 · 2.1 Workpiece Coordinate Offset
#ParameterExplanationSetting range (unit) 54G54 offsetSet the workpiece coordinate system and external workpiece coordinate offset values from G54 to G59. The workpiece coordinate system offset data can be set as an absolute value or incremental value. Basic machine coordinate system M External R (EXT) G55 W2 offset Reference workpiece point coordinate system G54 W1 workpiece coordinate system±99999.999 (mm) 55G55 offset 56G56 offset 57G57 offset 58G58 offset 59G59 offset 60EXT offset
Page 10 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2.2 Process Parameters
Page 10 · click to enlarge
Page 10
2. Machining Parameters 2.2 Process Parameters

2.2 Process Parameters

(No. of workpieces machined)

Mitsubishi Electronics CNC Controller Board (C64) — 2.2 Process Parameters diagram (page 10)
Fig. 18 · 2.2 Process Parameters
#ItemContentsSetting range (unit) 8001WRK COUNT MSet the M code that counts the No. of workpiece repeated machining. The No. will not be counted when set to 0.0 to 99 8002WRK COUNTThe current machining No. is displayed. Set the initial value.0 to 999999 8003WRK LIMITSet the maximum No. of workpieces machined. A signal is output to PLC when the No. of machining times is counted to this limit.0 to 999999

(Automatic tool length measurement)

Mitsubishi Electronics CNC Controller Board (C64) — 2.2 Process Parameters diagram (page 10)
Fig. 19 · 2.2 Process Parameters
#ItemContentsSetting range (unit) 8004SPEEDSet the feedrate during automatic tool length measurement.1 to 1000000 (mm/min) 8005ZONE rSet the distance between the measurement position and deceleration start point.0 to 99999.999 (mm) 8006ZONE dSet the tolerable zone of the measurement position. If the sensor signal turns on in front of d before the measurement position‚ or if the signal does not turn on after d is passed‚ an alarm will occur.0 to 99999.999 (mm)

(Automatic corner override)

Mitsubishi Electronics CNC Controller Board (C64) — 2.2 Process Parameters diagram (page 10)
Fig. 20 · 2.2 Process Parameters
#ItemContentsSetting range (unit) 8007OVERRIDESet the override value for automatic corner override.0 to 100 (%) 8008MAX ANGLESet the max. corner opening angle where deceleration should start automatically. If the angle is larger than this value‚ deceleration will not start.0 to 180 (degrees) 8009DSC. ZONESet the position where deceleration starts at the corner. Designate at which length point before the corner deceleration should start.0 to 99999.999 (mm)

(Wear data input)

Mitsubishi Electronics CNC Controller Board (C64) — 2.2 Process Parameters diagram (page 10)
Fig. 21 · 2.2 Process Parameters
#ItemContentsSetting range (unit) 8010ABS. MAX. (For L system only)Set the max. value when inputting the tool wear compensation amount. A value exceeding this setting value cannot be set.0 to 99.999 (mm) 8011INC. MAX. (For L system only)Set the max. value for when inputting the tool wear offset amount in the addition mode.0 to 99.999 (mm)
Page 11 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2.2 Process Parameters
Page 11 · click to enlarge
Page 11
2. Machining Parameters 2.2 Process Parameters

(Fixed cycle)

#ItemContentsSetting range (unit) 8012G73 n (For M system only)Set the return amount for G73 (step cycle).0 to 99999.999 (mm) 8013G83 nSet the return amount for G83 (deep hole drilling cycle).0 to 99999.999 (mm) 8014CDZ-VALE (For L system only)Set the screw cut up amount for G76‚ 78 (thread cutting cycle).0 to 127 (0.1 lead) 8015CDZ-ANGLE (For L system only)Set the screw cut up angle for G76‚ 78 (thread cutting cycle).0 to 89 (degrees) 8016G71 MINIMUM (For L system only)Set the minimum cut amount for the final cutting in G71‚ 72 (rough cutting cycle). If the final cutting amount is smaller than this value‚ the final cut will not be performed.0 to 99.999 (mm) 8017DELTA-D (For L system only)Set the change amount to the command cut amount D for G71‚ 72 (rough cutting cycle). Each cut amount will be the value obtained by adding or subtracting this value from command D‚ and thus‚ the amount can be changed each cut.0 to 99.999 (mm) 8018G84/G74 return (For M system only)Set up return length m at a G84/G74 pecking tap cycle. (Note) Set 0 to specify a usual tap cycle.0 to 99.999 (mm)

(High precision control)

#ItemContentsSetting range (unit) 8019R COMPSet up a compensation factor for reducing a control error in the reduction of a corner roundness and arch radius. Indicates a maximum control error (mm) in parentheses. The larger the setup value, the smaller the theoretical error will be. However, since the speed at the corner goes down, the cycle time is extended.0 to 99 (%) 8020DCC ANGLESet up the minimum value of an angle (external angle) that should be assumed to be a corner. When an inter-block angle (external angle) in highprecision mode is larger than the set value, it is determined as a corner and the speed goes down to sharpen the edge. If the set value is smaller than θ θ, the speed goes down to optimize the corner. (Note) If “0” is set, it will be handled as 5 degrees. The standard setting value is “0”.0 to 30 (degrees) 0: The angle will be 5 degrees.
Page 12 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2.3 Control Parameters
Page 12 · click to enlarge
Page 12
2. Machining Parameters 2.3 Control Parameters

2.3 Control Parameters

#ItemContentsSetting range (unit) 8101MACRO SINGLESelect the control of the blocks where the user macro command continues. 0: Do not stop while macro block continues. 1: Stop every block during signal block operation.0/1 8102COLL. ALM OFFSelect the interference (bite) control to the workpiece from the tool diameter during cutter compensation and nose R offset. 0: An alarm is output and operation stops when an interference is judged. 1: Changes the path to avoid interference.0/1 8103COLL. CHK OFFSelect the interference (bite) control to the work from the tool diameter during cutter compensation and nose R offset. 0: Performs interference check 1: Does not perform interference check0/1 8105EDIT LOCK BSelect the edit lock for program Nos. 8000 to 9999. 0: Program can be edited. 1: Editing of above program is prohibited.0/1 8106G46 NO REV-ERR (For L system only)Select the control for the compensation direction reversal in G46 (nose R offset). 0: An alarm is output and operation stops when the compensation direction is reversed (G41 → G42‚ G42 → G41). 1: An alarm does not occur when the compensation direction is reversed‚ and the current compensation direction is maintained.0/1 8107R COMPENSATION0: In arc cutting mode, the machine moves to the inside because of a delay in servo response to a command, making the arc smaller than the command value. 1: In arc cutting mode, the machine compensates the movement to the inside because of a delay in servo response to a command0/1 8108R COMP SelectSpecify whether to perform arc radius error correction over all axes or axis by axis. 0: Perform correction over all axes. 1: Perform correction over axis by axis. (Note) This parameter is effective only when "#8107 R COMPENSATION" is 1.0/1 8109HOST LINKNot used.0
Page 13 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2.4 Axis Parameters
Page 13 · click to enlarge
Page 13
2. Machining Parameters 2.4 Axis Parameters

2.4 Axis Parameters

# Item Contents Setting range (unit) 8201 AX. RELEASE Select the function to remove the control axis from the control target.

0. Control as normal 1: Remove from control target

8202 OT-CHECK OFF Select the stored stroke limit function set in #8204 and #8205.

0. Stored stroke limit valid 1: Stored stroke limit invalid

8203 OT-CHECK-CANCEL When the simple absolute position method ("#2049 type" is 9) is selected‚ the stored stroke limits I, II (or IIB) and IB will be invalid until the first reference point return is executed after the power is turned on.

0. Stored stroke limit II valid (according to #8202) 1: Stored stroke limit II invalid (Note) This setting (#8203) affects all the stored

stroke limits.

8204 OT-CHECK-N Set the coordinates of the (–) direction in the moveable range of the stored stroke limit II or the lower limit coordinates of the prohibited range of stored stroke limit IIB. If the sign and value are the same as #8205 (other than "0"), the stored stroke limit II (or IIB) will be invalid. If the stored stroke limit IIB function is selected, the prohibited range will be between two points even when #8204 and #8205 are set in reverse. When II is selected, the entire range will be prohibited.

–99999.999 to +99999.999 (mm)

8205 OT-CHECK-P Set the coordinates of the (+) direction in the moveable range of the stored stroke limit II or the upper limit coordinates of the prohibited range of stored stroke limit IIB.

–99999.999 to +99999.999 (mm)

8206 TOOL CHG. P Set the coordinates of the tool change position for G30. n (tool change position return). Set with coordinates in the basic machine coordinate system.

–99999.999 to +99999.999 (mm)

8207 G76/87 IGNR (For M system only)

Select the shift operation at G76 (fine boring) and G87 (back boring).

0. Shift effective 1: No shift
Show 4 more labels / short text on this page
0/1 · 0/1 · 0/1 · 0/1
Page 14 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2.5 Barrier Data
Page 14 · click to enlarge
Page 14
2. Machining Parameters 2.5 Barrier Data

# Item Contents Setting range (unit) 8208 G76/87 (–) (For M system only)

Specify the shift direction at G76 and G87.

0. Shift to (+) direction 1: Shift to (–) direction

8209 G60 SHIFT (For M system only)

–99999.999 to +99999.999 (mm) 8210 OT INSIDE The stored stoke limit function set in #8204 and #8205 prevents the machine from moving to the inside or outside of the specified range.

Set the last positioning direction and distance for a G60 (uni-directional positioning) command.

0. Inhibits outside area. (select stored stroke limit II.) 1: Inhibits inside area. (select stored stroke limit II B.)

2.5 Barrier Data

# Item Contents Setting range (unit) 8300 P0 (For L system only)

Set the reference X-coordinates of the chuck and the tail stock barrier. Set the center coordinate (Radius value) of workpiece by the basic machine coordinate system.

–99999.999 to +99999.999 (mm)

8301 8302 8303 8304 8305 8306

P1 P2 P3 P4 P5 P6 (For L system only)

Set the area of the chuck and tail stock barrier. (Radius value) Set the coordinate value from the center of workpiece for X-axis. Set the coordinate value by basic machine coordinate system for Z-axis.

–99999.999 to +99999.999 (mm)

0/1 · 0/1

Page 15 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 3.1 Base Parameters
Page 15 · click to enlarge
Page 15
3. I/O Parameters 3.1 Base Parameters

3. I/O Parameters

3.1 Base Parameters

<I/O> # <PORT No.> # <DEV. No.> <DEV. NAME> Specify the board No. to which the serial input/output device is connected to each application.

Set the input/output device No. for each application. The device Nos. are 0 to 4 and correspond to the input/output device parameters. The device name set in the input/output device parameter is also displayed for identification. DATA IN 9001 Specify the port for inputting the data such as machine program and parameters.

9002 Specify the No. of the device that inputs the data.

DATA OUT 9003 Specify the port for outputting the data such as machine program and parameters.

9004 Specify the No. of the device that outputs the data.

TAPE MODE 9005 Specify the input port for running with the tape mode.

9006 Specify the No. of the device to be run with the tape mode. MACRO PRINT

9008 Specify the No. of the device for the DPRINT command. PLC IN/OUT 9009 Specify the port for inputting/outputting various data with PLC.

9007 Specify the output port for the user macro DPRINT command.

9010 Specify the No. of the device for the PLC input/output. REMOTE PROG IN

9011 Not used. 9012 Not used.

Page 16 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 3.2 I/O Device Parameters
Page 16 · click to enlarge
Page 16
3. I/O Parameters 3.2 I/O Device Parameters

3.2 I/O Device Parameters

Parameters for up to five types of input/output devices can be set in DEV to . (Note) The parameters are set for each device.

9101 ~ Set the same settings for device 0. 9201 ~ Set the same settings for device 1. 9301 ~ Set the same settings for device 2. 9401 ~ Set the same settings for device 3. 9501 ~ Set the same settings for device 4.

# Item Contents Setting range (unit) 9101 9201 9301 9401 9501

Use alphabet characters‚ numerals and symbols to set a name within 3 characters. 9102 9202 9302 9402 9502

DEVICE NAME 0 DEVICE NAME 1 DEVICE NAME 2 DEVICE NAME 3 DEVICE NAME 4

Set the device name corresponding to the device No. Set a simple name for quick identification.

BAUD RATE Set the serial communication speed. 1: 9600 (bps) 2: 4800 3: 2400 4: 1200 5: 600 6: 300 7: 150 9103 9203 9303 9403 9503

STOP BIT Set the stop bit length used in the start-stop system. 1: 1 (bit)

2. 1.5 3: 2

9104 9204 9304 9404 9504

PARITY CHECK Specify whether to add the parity check bit to the data during communication.

0. Parity bit not added 1: Parity bit added

9105 9205 9305 9405 9505

EVEN PARITY Specify the odd or even parity when it is added to the data.

0. Odd parity 1: Even parity

9106 9206 9306 9406 9506

CHR. LENGTH Set the length of the data bit. 0: 5 (bit) 1: 6 2: 7 3: 8

Page 17 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 3.2 I/O Device Parameters
Page 17 · click to enlarge
Page 17
3. I/O Parameters 3.2 I/O Device Parameters

# Item Contents Setting range (unit) 9107 9207 9307 9407 9507

TERMINATOR TYPE The code to terminate data reading can be selected. 0 and 3: EOR

1 and 2EOB or EOR

9108 9208 9308 9408 9508

1. RTS/CTS method (This method can be used only for SIO2.) 2: No procedure (No handshaking) 3: DC code method 9109 9209 9309 9409 9509

HAND SHAKE Specify the transmission control method. The method will be no procedure if a value except 1 to 3 is set.

DC CODE PARITY Specify the DC code when the DC code method is selected.

0. No parity to DC code (DC3 = 13H) 1: DC code with parity (DC3 = 93H)

9111 9211 9311 9411 9511

DC2 / DC4 0: None / None 1: Yes / None 2: None / Yes 3: Yes / Yes 9112 9212 9312 9412 9512

DC2/DC4 OUTPUT Specify the DC code handling when outputting data to the output device.

CR OUTPUT Specify whether to insert the code just before the EOB (L/F) code during output.

0. Do not add 1: Add

9113 9213 9313 9413 9513

EIA Output In data output mode, select the ISO or EIA code for data output. In data input mode, the ISO and EIA codes are identified automatically.

0. ISO code output 1: EIA code output

9114 9214 9314 9414 9514

FEED CHR. Specify the length of the tape feed to be output at the start and end of the data during tape output.

0 to 999 (characters)

9115 9215 9315 9415 9515

PARITY V Specify whether to check the parity of the No. of characters in block during data input. The No. of characters is factory-set so that the check is valid at all times.

0. Do not perform parity V check 1: Perform parity V check
Page 18 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 3.2 I/O Device Parameters
Page 18 · click to enlarge
Page 18
3. I/O Parameters 3.2 I/O Device Parameters

# Item Contents Setting range (unit) 9116 9216 9316 9416 9516

TIME-OUT (s) Set the time out time to detect an interruption in communication. The time out is not checked when 0 is set, so the waiting time will be infinite. The screens cannot be changed during the waiting time. Set this time to 10 as the standard.

0 to 30 (s)

9117 9217 9317 9417 9517

DR OFF Specify whether to check the DR data at the data input/output.

0. DR valid 1: DR invalid

9118 9218 9318 9418 9518

DATA ASC II 0: Output in ISO/EIA code (Depends on whether #9113, #9213, #9313, #9413, or #9513 EIA output parameter is set up) 1: Output in ASC II code

9119 9219 9319 9419 9519

INPUT FORM Specify the mode for input (collation). 0: Standard input (Data from the very first EOB is handled as significant information.) 1: EOBs following the first EOB of the input data are skipped until data other than EOB is input.

9121 9221 9321 9421 9521

EIA CODE [ When outputting with the EIA codes, special ISO codes not included in EIA can be output with alternate codes. For each special code, designate a code (as a hexadecimal) that is not duplicated with existing EIA codes. (Continued on the next page.)

0 to FF (hexadecimal)

9122 9222 9322 9422 9522

9123 9223 9323 9423 9523

9124 9224 9324 9424 9524

Show 5 more labels / short text on this page
0/1 · 0/1 · ] · # · ∗
Page 19 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 3.2 I/O Device Parameters
Page 19 · click to enlarge
Page 19
3. I/O Parameters 3.2 I/O Device Parameters

# Item Contents Setting range (unit)

9125 9225 9325 9425 9525

(Continued from the previous page.)

9126 9226 9326 9426 9526

:

9127 9227 9327 9427 9527

9128 9228 9328 9428 9528

= · $ · !

Page 20 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — MENU I/O PAR PROCESS WORK
Page 20 · click to enlarge
Page 20
4. Setup Parameters

4. Setup Parameters

Pressing the menu key SETUP displays the OPEN SETUP PARAM screen.

The system’s basic parameters are normally hidden as setup parameters to prevent mistaken operations and to simplify the display. The setup parameters can be displayed and set by making a declaration to open the setup parameters on this screen.

PARAM 3 [OPEN SETUP PARAM]

Open the menu setup parameter? *YES : "Y" "INPUT" *NO : "N" "INPUT"

MENU I/O PAR PROCESS WORK

SETUP

1. Select the setup parameter. Key-in Y in # ( )‚ and then press INPUT . The basic specification parameter screen appears and the normally hidden setup parameter menu will display. The required menu can be selected to display and set the setup parameters.
2. Cancel the setup parameter selection. Key-in N in # ( )‚ and then press INPUT . The setup parameter menu will disappear. (Note) The setup parameters are not displayed when the power is turned on.

Refer to "5. Base Specifications Parameters" and following for details on the setup parameters. Be sure to turn off the power supply after selecting the setup parameter.

# ( )

Page 21 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 21 · click to enlarge
Page 21
5. Base Specifications Parameters

5. Base Specifications Parameters

After setting up the parameter (PR) listed in the table, turn off the NC power. To validate the parameter, turn on the power again.

# Items Details Setting range (unit)

Specify the presence of the PLC axes and the 1st to 7th part systems with 1 or 0. 0: Not used 1: Used

axisno Number of axes

Set No. of axes in each part system and the No. of PLC axes. Set so that the total of the NC axes and PLC axes is less than the maximum number of controllable axes.

iunit Input setup unit

Specify the input setting value for each part system and the PLC axis. The parameter units will follow this specification.

B: 1 µm C: 0.1 µm

1013 axname Axis name Specify each axis’ name address with an alphabetic character. Use the characters X‚ Y‚ Z‚ U‚ V‚ W‚ A‚ B or C. Do not specify the same address in one part system. The same address can be specified as the other part system. The PLC address does not need to be set. (The axis name is displayed as 1 and 2.)

Axis addresses such as X, Y, Z, U, V, W, A, B, and C

1014 incax Increment command axis name

When specifying the program movement rate’s absolute or incremental method with an address‚ specify the incremental command axis name address with an alphabetic character. The address that can be used is the same as "#1013 axname". Specify an address that is different from that #1013. Setting is not required if absolute/incremental command with addresses is not performed ("#1076 Abslnc" = 0).

Specify the minimum unit of the program movement amount. cunit Movement amount for movement command 1 10: 0.001 mm ( 1 µm) 100: 0.01 mm ( 10 µm) 1000: 0.1 mm (100 µm) 10000: 1.0 mm If there is a decimal point in the movement command‚ the decimal point position will be handled as 1mm regardless of this setting.

10 1 µm

100 10 µm

1000 100 µm

iout Inch output Specify whether the machine system (ball screw pitch‚ position detection unit) is an inch unit system or metric unit system.

0. Metric unit system 1: Inch unit system
Show 4 more labels / short text on this page
SYS_ON Part system · validation setup · cunit Command unit · 10000 1 mm
Page 22 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 22 · click to enlarge
Page 22
5. Base Specifications Parameters

# Items Details Setting range (unit)

Specify whether the axis is a rotary axis or linear axis. For the rotary axis‚ the position display will be 360 degrees‚ and the axis will return to 0 degrees. If the position display is to be continuously displayed even with the rotary axis‚ set the axis as a linear axis

0. Linear axis 1: Rotary axis

ccw Motor CCW Specify the direction of the motor rotation to the command direction.

0. Rotates clockwise 1: Rotates counterclockwise
0. Rotates clockwise (looking from motor shaft) with the forward rotation command. 1: Rotates counterclockwise (looking from motor shaft) with the forward rotation command.

dia Diameter specification axis

Specify whether the program movement amount is to be commanded with the diameter dimension or as movement amount. When the movement amount is commanded with the diameter dimensions‚ 5mm will be moved when the command is a movement distance of 10mm. The movement amount per pulse will also be halved during manual pulse feed. Among parameters concerning length‚ the tool length‚ the wear compensation amount and the workpiece coordinate offset are displayed in diameter value when diameter is specified‚ but other parameters are always displayed in radius value.

0. Command with movement amount 1: Command with diameter dimension

Specify 1 when the NC control axis is used as the spindle.

0. The NC control axis is used as the servo axis. 1: The NC control axis is used as the spindle.

rot Rotational axis · sp_ax Spindle Interpolation

Page 23 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 23 · click to enlarge
Page 23
5. Base Specifications Parameters

# Items Details Setting range (unit)

1025 l_plane Initial plane selection

Specify the plane to be selected when the power is turned on or reset. When 0 is specified, 1 is assumed (X-Y plane).

1. X-Y plane (G17 command state) 2: Z-X plane (G18 command state) 3: Y-Z plane (G19 command state)

Base axis I Base axis J Base axis K

Specify the basic axis address that composes the plane. Specify the axis address set in “#1013 axname”. Set the axis name even when there is no need to configure a plane, such as the case of 2-axis specifications. Normally‚ when X‚ Y and Z are specified respectively for base_l‚_J‚_K‚ the following relation will be established:

Control axis addresses such as X, Y, and Z

G17: X-Y G18: Z-X G19: Y-Z Specify the desired address to set an axis address other than the above.

1029 aux_I Flat axis I If there is an axis parallel to "#1026 base_l"‚ specify that axis address.

Control axis addresses such as X, Y, and Z

1030 aux_J Flat axis J If there is an axis parallel to "#1027 base_J"‚ specify that axis address.

Control axis addresses such as X, Y, and Z

1031 aux_K Flat axis K If there is an axis parallel to "#1028 base_K"‚ specify that axis address.

Control axis addresses such as X, Y, and Z

1026 1027 1028 · base_l base_J base_K

Page 24 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — # (1060) DATA ( 1) ( ) INPUT
Page 24 · click to enlarge
Page 24
5. Base Specifications Parameters

# Items Details Setting range (unit)

1037 cmdtyp Command type

Specify the program G code series and compensation type.

cmdtyp G code series Compensation type 1 System 1 (for M) Type A (one compensation amount for one compen- sation number) 2 System 2 (for M) Type B (shape and wear amounts for one compen- sation number)

3 System 2 (for L) Type C (two kinds of compensation amount of shape and wear per compensation No.)

4 System 3 (for L) Same as above

5 System 4 (for special L)

6 System 5 (for special L)

7 System 6 (for special L)

8 System 7 (for special L)

There are some items in the specifications that can be used or cannot be used according to the value set in this parameter. The file structure may also change depending on the compensation data type. Thus‚ after changing this parameter‚ initialize the system with "#1060 SETUP".

# (1060) DATA ( 1) ( ) INPUT

"BASE PARA SET? (Y/N)" : N INPUT

"FORMAT? (Y/N)" : Y INPUT

↓ "SETUP COMPLETE" (Note) The machining program is cleared with the

above operations. Back up necessary machining programs in an external memory before initializing.

1038 plcsel Ladder selection

Specify the PLC type. 0 to 2

Show 6 more labels / short text on this page
Same as above · Same as above · Same as above · Same as above · ↓ · ↓
Page 25 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 25 · click to enlarge
Page 25
5. Base Specifications Parameters

# Items Details Setting range (unit)

1039 spinno Number of spindles

Specify the existence of a spindle.

0. No spindle 4: Four spindles 1: One spindle 5: Five spindles 2: Two spindles 6: Six spindles 3: Three spindles 7: Seven spindles

Specify the parameter unit system for the position and length.

0. Metric system 1: Inch system

l_inch Initial state (inch)

Specify the unit system for the program movement amount when the power is turned on or reset and for position display.

0. Metric system 1: Inch system

pcinch PLC axis command (inch)

Specify the unit system for the commands to the PLC axis.

0. Metric system 1: Inch system

1043 lang Select language displayed

Specify the display language.

0. Japanese display 1 : English display 21: Polish display (Note) If no character package is available for a

specified language, the screen is displayed in English.

Specify the number of MR-J2-CT axes connected. As for C6/C64 system, up to 5 axes of MR-J2-CT can be connected, thus, the setting range is 0 to 5.

(Note) Selection of inch and metric unit

When set value of "#1041 I_inch" is changed‚ the unit of length is changed after reset. Among parameters concerning length‚ following items are not changed automatically‚ therefore change the set values to agree with the new unit system when the unit system is changed.

Tool compensation amount (Tool length compensation amount‚ tool wear compensation amount and tool tip compensation amount) Workpiece coordinate offset Machining parameter #8004 SPEED #8013 G83n #8052 PULL UP #8005 ZONE r #8016 G71 MINIMUM #8053 G73U #8006 ZONE d #8017 G71 DELTA-D #8054 W #8009 DSC. ZONE #8018 G84/G74n #8056 G74 RETRACT #8010 ABS. MAX. #8027 Toler-1 #8057 G76 LAST-D #8011 INC. MAX. #8028 Toler-2 #8012 G73n #8051 G71 THICK Axis parameter #8204 OT-CHECK-N #8205 OT-CHECK-P #8206 TOOL CHG.P #8209 G60 Shift Barrier data #8300 – #8306 Basic specification parameter #1084 RadErr

#8004 SPEED is 10 inches/min. unit for the inch system.

Show 4 more labels / short text on this page
M_inch Constant · input (inch) · 0/1/21 · auxno MR-J2-CT connections
Page 26 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 26 · click to enlarge
Page 26
5. Base Specifications Parameters
Mitsubishi Electronics CNC Controller Board (C64) — 5. Base Specifications Parameters diagram (page 26)
Fig. 22 · 5. Base Specifications Parameters

one-touch setup‚ so confirm the data before executing. This parameter will automatically be set to 0 when the power is turned on.

Defines whether to update the absolute value data during automatic handle interrupt. This parameter is valid only when "#1145 l_abs" is set to 1.

0. Does not update (shift coordinates by the amount of the interruption) 1: Updates (same coordinates as when interrupt did not occur will be applied.)
Page 27 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 27 · click to enlarge
Page 27
5. Base Specifications Parameters

# Items Details Setting range (unit)

1062 T_cmp Tool offset function

Specify whether the tool length offset and wear compensation is valid during T command execution.

Setting value Tool length offset Wear compensation 0 Valid Valid 1 Valid Invalid 2 Invalid Valid 3 Invalid Invalid

1063 mandog Manual dog-type

The initial return to the reference point is performed with dog-type return after the power is turned on‚ and the coordinate system is established. Specify the manual reference point return method after the coordinate system is established with this parameter. (This setting is not required when using absolute position detection.)

0. High speed return 1: Dog-type

Specify whether to correct the error when the servo is off.

0. Does not correct the error 1: Corrects the error

1065 JOG_H JOG response type

Set up an improved JOG response type.

0: Conventional specification The system is started and stopped by signals via ladder without reference to external input signals. 1: Type 1 The system is started up and stopped by external signals. 2: Type 2 The system is started up and stopped by performing the AND operation for external signals and signals via ladder. 3: Type 3 The system is started up when signals via ladder rise. It is stopped when external signals and signals via ladder fall. 4: Type 4 Reference point return mode:

The system is started up and stopped by signals via ladder without reference to external input signals (conventional specification). Non-reference point return mode:

The system is started up and stopped by performing AND for external signals and signals via ladder (type 2).

svof Error correction

Page 28 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — JOG_D ± JOG
Page 28 · click to enlarge
Page 28
5. Base Specifications Parameters

# Items Details Setting range (unit)

1066 JOG_HP Select JOG activation (+) device

Specify the number of the device that inputs +JOG activation signals. The device type is specified by "#1071 JOG_D". The effective range of set values vary depending on the device type. A value outside of the effective range is invalid if specified. (Note) The setting range of this parameter has been

X: 0000 to 03FF

(hexadecimal) M0000 to 8191

expanded on the software Ver.D0 and later.

1067 JOG_HN Select JOG activation (−) device

Specify the number of the device that inputs -JOG activation signals. The device type is specified by "#1071 JOG_D". The effective range of set values vary depending on the device type. A value outside of the effective range is invalid if specified. (Note) The setting range of this parameter has been

X: 0000 to 03FF

(hexadecimal) M0000 to 8191

expanded on the software Ver.D0 and later.

slavno Slave axis number

Specify the axis number of a slave axis to be synchronized. The axis number is an NC number excluding the spindle and PLC axis. Two or more slave axes cannot be set up for one master axis. This parameter "slavno" cannot be set up for a slave axis. A multiple part system cannot be set up so that the relation between the master and slave axes extends over a part system.

0. No slave axis 1 to 6: First to sixth axes

no_dsp Axis with no

Set up an axis that displays no counter. This option is valid on the counter display screen (e.g. POSITION screen).

0. Displays the counter 1: Does not display the counter.

1070 axoff Axis removal

Define an axis that enables axis removal control. 0: Disables axis removal. 1: Enables axis removal

JOG_D ± JOG

Specify the number of the device that inputs ±JOG activation signals.

activation signal device name

0. X device 1 or 2: M device Set the JOG_HP (#1066) and JOG_HN (#1067) parameters according to this device specification parameter. (Note) The setting range of #1066 and #1067

parameters has been expanded on the software Ver.D0 and later.

(decimal) · (decimal) · counter display

Page 29 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 29 · click to enlarge
Page 29
5. Base Specifications Parameters

# Items Details Setting range (unit)

1073 I_Absm Initial absolute value

Specify the absolute value/incremental value mode for when the power is turned on or reset.

0. Incremental value command mode 1: Absolute value command mode

1074 l_Sync Initial synchronous feed

Specify the feedrate specification mode for when the power is turned on or reset.

0. Asynchronous feed 1: Synchronous feed
0. Asynchronous feed (feed per minute) 1: Synchronous feed (feed per rotation)

1075 I_G00 Initial G00 Specify the linear command mode for when the power is turned on or reset.

0. Linear interpolation 1: Positioning
0. Linear interpolation (G01 command state) 1: Positioning (G00 command state)

1076 Abslnc (For L system only)

The absolute value/incremental commands can be issued by using the absolute value address and incremental value address for the same axis.

0. Absolute/ incremental with G command 1: Absolute/ incremental with address code
0. Absolute/incremental with G command 1: Absolute/incremental with address code (The "#1013 axname" address will be the absolute value command‚ and "#1014 incax" address will be the incremental value command)

1077 radius Incremental command for diameter specification axis

Specify if the diameter specification axis’ ("#1019 dia" is set to 1) incremental value command uses the diameter value or radius value

0. Diameter value 1: Radius value

1078 Decpt2 Decimal point type 2

Specify the unit of position commands that do not have a decimal point.

0. The min. input command unit is used 1: 1mm (or 1inch) unit is used
0. The min. input command unit is used (follows "#1015 cunit") 1: 1mm (or 1inch) unit is used

1079 F1digt Validate F1 digit

Specify whether to execute the F command with a 1-digit code command or with a direct numerical command.

0. Direct numerical command 1: 1-digit code command
0. Direct numerical command (command feedrate during feed per minute or rotation) 1: 1-digit code command (feedrate specified with "#1185 spd_F1" to "#1189 F5")

ABS/INC address

Page 30 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 30 · click to enlarge
Page 30
5. Base Specifications Parameters

# Items Details Setting range (unit)

1080 Dril_Z (For M system only)

Specify a fixed-cycle boring axis.

0. Uses an axis perpendicular to the selected plane as the boring axis. 1: Uses the Z axis as the boring axis regardless of the selected plane.

1081 Gmac_P Give priority to G code parameter

Specify the G code priority relationship during the macro call with the G command.

0. G code used in system is priority 1: Registered G code for call out is priority

1082 Geomet (For L system only)

Geometric Specify the validity of the geometric function. As the designated address code is used exclusively for geometric‚ if "A" or "C" is used for the axis address or 2nd miscellaneous command code‚ "A" that is the axis address may be handled as the geometric’s angle specification. Take special care to the setting of the axis name‚ etc.‚ when using this function.

0. Invalid 1: Valid

1084 RadErr Arc error Specify the tolerable error range when a deviation occurs in the end point and center coordinate in the circular command.

0 to 1.000 (mm)

1085 G00Drn G00 dry run Specify whether to apply dry run (feed with manual setting speed instead of command feedrate) to the G00 command.

0. Does not apply to G00 (moves at rapid traverse feedrate) 1: Applies to G00 (moves at manual set feedrate)

1086 G0lntp G00 non- interpolation

Specify the G00 movement path type

0. Moves linearly toward the end point (interpolation type) 1: Moves to the end point of each axis at the rapid traverse feedrate for each axis (non-interpolation)

1087 G96_G0 Constant surface speed control by rapid traverse feed command

Specify how to handle the cycle speed for the G00 command when using the constant surface speed control function.

0. Calculates the cycle speed constantly even during G00 movement. 1: Calculates the cycle speed at the block end point in the G00 command.
Show 6 more labels / short text on this page
Specify boring axis · 0/1 · 0/1 · 0/1 · 0/1 · 0/1
Page 31 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 31 · click to enlarge
Page 31
5. Base Specifications Parameters

# Items Details Setting range (unit)

1088 G30SL Disable G30 soft limit

Specify how to handle the soft limit during G30 (2nd reference point return) movement.

0. Soft limit valid during G30 movement 1: Soft limit invalid during G30 movement

1089 Cut_RT Short cut for rotary axis

Specify how to handle the short cut control for the rotary axis ("#1017 rot" is set to 1).

0. No short cut 1: Use short cut
0. No short cut (move toward end point) 1: Uses short cut (when using the absolute value command‚ move in the direction where the movement amount will be 180 degrees or less)

1090 Lin_RT Linear rotary axis

Specify how to handle a command for the rotary axis that exceeds 360 degrees.

0. For absolute value commands that exceed 360 degrees‚ the value will be converted into a remainder of 360 degrees and the axis will move.
ExampleIf the command is 420 degrees‚ the

applied value will be 60 degrees. 1: For absolute value commands that exceed 360 degrees‚ the axis will move in the same manner as a linear axis.

ExampleIf the command is 420 degrees‚ the axis

will pass the 360 degree position and will move to the 60 degree position.

1091 Mpoint Ignore middle point

Specify now to handle the middle point during G28 and G30 reference point return.

0. Moves to the reference point after passing the middle point designated in the program. 1: Ignores the middle point designated in the program and move straight to the reference point.

1092 Tchg _A Replace tools for additional axis

Specify the movement of the additional axis during tool change position return.

0. The additional axis does not move with the tool change position return command. 1: After returning the standard axis with the tool change position return command‚ the additional axis also returns to the tool change position.

1093 Wmvfin Waiting method between part systems

Specify the method for waiting between part systems. When the movement command is found in the wait command ! block:

0. Waits before executing movement command 1: Waits after executing movement command

1094 Tl_SBK (for L system only)

Select life count for single block

Select whether to count the data units to be used for a single block when using the tool life management II function (lathe system).

0. Does not count the data units. 1: Count the data units.
Show 6 more labels / short text on this page
0/1 · 0/1 · 0/1 · 0/1 · 0/1 · 0/1
Page 32 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 32 · click to enlarge
Page 32
5. Base Specifications Parameters

# Items Details Setting range (unit)

1095 T0tfof TF output Select how to handle TF for T00 command.

0. TF is output. 1: TF is not output

1096 T_Ltyp (For L system only)

Tool life management type

Specify the tool life management type. 1: Life manage- ment type l 2: Life manage- ment type ll

1097 T1digt Tool wear compen- sation number 1-digit command

Specify the No. of digits in the tool wear compensation No. in the T command.

0. The 2 high-order digits are the tool No.‚ and the 2 low-order digits are the wear compensation No. 1: The 3 high-order digits are the tool No.‚ and the 1 low-order digit is the wear compensation No. This parameter will be fixed to 0 when tool life management II is selected.

1098 Tlno. Tool length offset number

Specify the No. of digits in the tool length offset No. in the T command.

0. The 2 or 3 high-order digits are the tool No. The 2 or 1 low-order digits are the tool length offset and wear compensation Nos. 1: The 2 or 3 high-order digits are the tool No. and tool length offset Nos. The 2 or 1 low-order digits are the wear compensation No.

1099 Treset Cancel tool wear compen- sation amount

Specify how to handle tool compensation vector when resetting system.

0. Clears 1: Saves
0. Clears the tool length and wear compensation vectors when resetting. 1: Saves the tool length and wear compensation vectors when resetting. When the values are cleared‚ the compensation will not be applied‚ so the axis will move the compensation amount in the next compensation operation. When the values are saved‚ the compensation will be applied‚ so the axis will shift the differential amount of the compensation amount in the next compensation operation.

0/1 · 0/1 · 0/1

Page 33 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 33 · click to enlarge
Page 33
5. Base Specifications Parameters

# Items Details Setting range (unit)

1100 Tmove Tool wear compen- sation

Specify the period to perform tool length offset and wear compensation.

0: Compensate when T command is executed. 1: Superimpose and compensate with the movement command in the block where the T command is located. If there is no movement command in the same block‚ compensation will be executed after the movement command is superimposed in the next movement command block. 2: Compensate when the T command is executed. 1: Superimpose and compensate a tool length offset with the movement command in the same block. If there is no movement command in the same block, compensation will be executed after the movement command is superimposed in the next movement command block.

1101 Tabsmv Tool wear compen- sation method

Specify the type of movement command when "#1100 Tmove" is set to 1.

0. Compensate regardless of the command type. 1: Compensate only with the absolute value command.
0. Compensate regardless of the movement command type. 1: Compensate only at the movement command in the absolute value command.

1102 tlm (For L system only)

Manual tool length measuring system

Specify the measurement method for manual tool measurement l.

0. Basic position method 1: Measured value input method
0. Align tool with basic position 1: Input measurement results

1103 T_life Validate life management

Select the usage of the tool life management function.

0. Do not use. 1: Perform tool life management control.

1104 T_Com2 Tool command method 2

Select the command method for when "#1103 T_Life" is set to 1.

0. Handle the program tool command as the group No. 1: Handle the program tool command as the tool No.

0/1

Page 34 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 34 · click to enlarge
Page 34
5. Base Specifications Parameters

# Items Details Setting range (unit)

1105 T_Sel2 Tool selection method 2

Select the tool selection method for when "#1103 T_Life" is set to 1.

0. Select in order of registered No. from the tools used in the same group. 1: Select the tool with the longest remaining life from tools used in the same group and the unused tools.

1106 Tcount (For L system only)

Specify the function when address N is omitted when inputting data (G10 L3 command) for tool life manage- ment function ll.

0. Time specified input 1: No. of times specified input

1107 Tllfsc (For L system only)

Split life management display screen

Set up the number of groups to be displayed on the tool life management II (lathe system) screen.

0. Displayed group count 1 1: Displayed group count 2 2: Displayed group count 4

1108 TlrectM (For L system only)

Life manage- ment re-count M code

Set up the M code for tool life management II (lathe system) re-count.

Validate alternate M code

Select the user macro interrupt with the substitute M code.

0. Alternate M code invalid 1: Alternate M code valid

1110 M96_M M96 alternate M code

Specify an M code to replace M96 when "#1109 subs_M" is set to 1.

3 to 97 (excluding 30)

1111 M97_M M97 alternate M code

Specify an M code to replace M97 when "#1109 subs_M" is set to 1.

Specify the validity conditions for the user macro interrupt signal.

0. Valid when interrupt signal (UIT) turns off to on. 1: Valid when interrupt signal (UIT) is ON.
0. Valid when interrupt signal (UIT) turns off to on. 1: Valid when interrupt signal (UIT) is ON.

INT_2 Validate interrupt method type 2

Specify the movement after user macro interrupt signal (UIT) input.

0. Execute interrupt program without waiting for block being executed to end. 1: Execute interrupt program after completing block being executed.
Show 6 more labels / short text on this page
0/1 · Life manage- ment count · subs_ M · S_TRG Validate · status trigger system · 0/1
Page 35 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 35 · click to enlarge
Page 35
5. Base Specifications Parameters

# Items Details Setting range (unit)

1114 mcrint Macro argument initialization

Select whether to clear statements other than specified arguments by macro call. Also, select whether to clear local variables by power-on and resetting.

0. Delete non-specified arguments by macro call. 1: Retain non-specified arguments by macro call. 2: Retain non-specified arguments by macro call and clear local variables by power-on and resetting.

1115 thwait Waiting for thread cutting

Set the queue number during screw thread cutting when the chamfering is not valid.

0 to 99 (Approx. 4 ms.) Standard set value: 4

1116 G30SLM Invalidate soft limit (manual operation)

Enable this function when disabling the soft limit check function from the second to the fourth reference point return by manual operation.

0. Enable soft limit function. 1: Disable soft limit function.

1117 H_sens Handle response switch

Switch the handle response mode when feeding the handle.

0. Standard handle response 1: High-speed handle response

1118 mirr_A (For L system only)

Select how to set up the length of tools on facing turret (double-turret mirror image)

Select one of the following two methods.

0. Set up the current length of tools on facing turret. 1: Set up a value, assuming that the tools on facing turret is in the same direction as that of those on the base turret.

1119 Tmiron (For L system only)

Select the double-turret mirror image with T command

Select whether to validate the double-turret mirror image with the T command.

0. Invalid 1: Valid

TofVal Change macro variable

Specify whether to change the macro variable (tool offset) numbers for shape compensation and wear compensation.

0. Do not change. (Conventional specifications) 1: Change the shape and wear compensation variable numbers each for X, Z, and R.
Show 4 more labels / short text on this page
0/1/2 · 0/1 · 0/1 · 0/1
Page 36 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 36 · click to enlarge
Page 36
5. Base Specifications Parameters

# Items Details Setting range (unit)

1121 edlk_c Edit lock C Specify whether to prohibit editing of program Nos. 9000 to 9999. 0: Editing possible 1: Editing prohibited

pglk_c Program display lock

The display and search of program Nos. 9000 to 9999 can be prohibited. Specify whether to prohibit display and search.

0. Display and search is possible 1: Program details are not displayed 2: Program details are not displayed‚ and operation search is prohibited. The program details will not be displayed‚ but the program No. and sequence No. will display in the prohibited state.

1123 origin Origin zero inhibition

Select whether to use the origin zero function. 0: Use 1: Do not use

1124 ofsfix Fix tool wear compen- sation number

Specify whether to automatically increment the offset No. by 1 with the input or to display the No. as it is in the setting on the tool offset screen.

0. Increment the # No. by 1 when the input key is pressed. (Same as general parameters) 1: # No. does not change even if input key is pressed. When making settings in sequence‚ 0 is handier. When changing and setting repeatedly while adjusting one offset value‚ 1 is handier

1125 real_f Actual feedrate display

Specify the feedrate display on the monitor screen. 0: Command speed 1: Real move- ment feedrate

1126 PB_G90 Not used. 0

1127 DPRINT DPRINT alignment

Specify the alignment for printing out with the DPRINT function.

0. No alignment‚ data is printed with left justification. 1: Align the minimum digit and output.

0/1 · 0/1

Page 37 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 37 · click to enlarge
Page 37
5. Base Specifications Parameters

# Items Details Setting range (unit)

1128 RstVCI Clear variables by resetting

Specify how to handle the common variables when resetting.

0. Common variables do not change after resetting. 1: The following common variables are cleared by resetting:

During variable 100 sets specifications:

#100 to #149 are cleared. During variable 200 or 300 sets specifications:

#100 to #199 are cleared.

1129 PwrVCl Clear variables by power-on

Specify how to handle the common variables when the power is turned on.

0. The common variables are in the same state as before turning the power off. 1: The following common variables are cleared when the power is turned on.

During variable 100 sets specifications:

#100 to #149 are cleared. During variable 200 or 300 sets specifications:

#100 to #199 are cleared.

1130 set_t Display selected tool number

Specify the tool command value display on the POSITION screen.

0. T-modal value of program command is displayed. 1: Tool number sent from PLC is displayed.

Fldcc Feed forward filter

Parameter to suppress acceleration changes with a filter when starting acceleration or deceleration. Specify the parameter in bits.

bit1: 7.1 (ms) bit2: 14.2 (ms) bit3: 28.4 (ms) bit4: 56.8 (ms) If bit 1 to bit 4 are all 0 or two or more bits of bit 1 to bit 4 are 1, 3.5 ms is set up.

7 6 5 4 3 2 1 0

1132 CRT CRT brightness control

This parameter adjusts the brightness of the CRT display unit.

–3: Highest luminance (Brightest state) –3: Lowest luminance (Darkest state) Adjust this parameter to an appropriate brightness between –3 and 3. The EL display unit does not have brightness adjustment‚ so setting is not required.

Show 4 more labels / short text on this page
0/1 · 0/1 · 0/1 · Feed forward filter
Page 38 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 38 · click to enlarge
Page 38
5. Base Specifications Parameters

# Items Details Setting range (unit)

1133 ofsmem Select how to set up tool wear compensa- tion screen

Select the number stored by previous setup when selecting the tool wear compensation screen.

0. Does not display the number when selecting the screen. 1: Displays the stored number when selecting the screen.

1134 LCDneg LCD reverse display

Specify 1 to reverse the display on the 10.4-type monochrome LCD.

0. Normal display 1: Reverse display

1135 unt_nm Unit name Set up a unit name. Set up the unit name with 4 or less characters consisting of both alphabets and numbers. If 0 is set up, the unit name is not displayed.

4 or less characters consisting of both alphabets and numbers

1138 Pnosel Not used. 0

1139 edtype Edit type selection

Set up an edit type.

0. Screen edit type (M50 or equivalent operation) 1: Screen edit type (The screen of EDIT or MDI is changed automatically according to the selected operation mode.) 2: Word edit type (The screen of EDIT or MDI is changed automatically according to the selected operation mode.)

1140 Mn100 M code number

First number of M code that corresponds to setup number from 100 to 199.

1141 Mn200 M code number

First number of M code that corresponds to setup number from 200 to 299.

1142 Mn300 M code number

First number of M code that corresponds to setup number from 300 to 399.

1143 Mn400 M code number

First number of M code that corresponds to setup number from 400 to 499.

1144 mdlkof MDI setup lock

Select whether to enable MDI setup in non-MDI mode. 0: Disable MDI

setup 1Enable MDI setup

0/1 · 0/1/2

Page 39 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 39 · click to enlarge
Page 39
5. Base Specifications Parameters

# Items Details Setting range (unit)

1145 I_abs Manual ABS parameter

Specify how to handle the absolute position data during automatic handle interrupt.

0. Absolute position data is renewed if manual ABS switch is on. Data is not renewed if switch is off. 1: Follows the intabs state when "#1061 intabs" is valid.

1146 Sclamp Spindle rotation clamp function

Specify how to handle the spindle rotation clamp function with the G92S command.

0. G92S command is handled as a clamp command only in the G96 state (during constant surface speed control). G92S will be handled as normal S command in G97 state (constant surface speed OFF). 1: The S command in the same block as G92 is constantly handled as a clamp command.

1147 smin_V Minimum spindle rotation speed clamp type

Specify the type of spindle min. rotation speed clamp value.

0. Rotation speed setting 1: Output voltage coefficient setting
0. Rotation speed setting 1: Output voltage coefficient setting Set the "#3023 smini" parameter according to this type setting.

1148 I_G611 Initial high precision

Specify the default mode after power-on or resetting.

0. G64 (cutting mode) 1: G61.1 (high precision control mode)

1149 cireft Arc decelera- tion speed change

Specify whether to enable deceleration at the arc entrance or exit.

0. Disable 1: Enable

1150 F1dc0 G00 feed forward filter

This parameter is used to filter acceleration changes at the start of rapid acceleration/deceleration. Specify the filters in bit units.

bit1: 7.1 (ms) bit2: 14.2 (ms) bit3: 28.4 (ms) bit4: 56.8 (ms) If bit 1 to bit 4 are all 0 or two or more bits of bit 1 to bit 4 are 1, 3.5 ms is set up.

7 6 5 4 3 2 1 0

G00 feed forward filter

Feed forward filter G00 and G01 independent 0: Common 1: Independent

1151 rstint Reset initial Specify whether to initialize various modals by resetting.

0. Does not initialize. 1: Initializes.
Show 5 more labels / short text on this page
0/1 · 0/1 · 0/1 · 0/1 · 0/1
Page 40 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SERVO2
Page 40 · click to enlarge
Page 40
5. Base Specifications Parameters

# Items Details Setting range (unit)

1152 I_G20 Initial command unit

Specify whether the default mode after power-on or resetting, inch command or metric command mode.

0. Metric command (G21 command state) 1: Inch command (G20 command state) Valid when reset input is made. Related parameter: Bit 6 "Select setting and display

pdoor Door interlock II (for each part system)

Specify whether to control door interlock II independently for each of the two part systems. When door interlock II is controlled for each part system of the two part systems, part system 1 is connected to SERVO1 of the base I/O unit and part system 2 is connected to SERVO2 of the base I/O unit. C6/C64 unit When the auxiliary axis (MR-J2-CT) is used, connect it to the SERVO2 side (after the spindle). This validates door interlock II of part system 2.

SERVO1

AMP AMP AMP Part system 1

SERVO2

AMP AMP AMP Part system 2

0: Do not use door interlock II independently for each part system. 1: Use door interlock II independently for each part system. When 0 is specified for this parameter, "Signal input device 1 for door interlock II (#1155 DOOR_m)" and "Device number 2 for door interlock II signal input (#1156 DOOR_s) are valid. When 1 is specified, "Signal input device 1 for door interlock II: for each part system (#1511 DOORPm)" and "Signal input device 2 for door interlock II: for each part system (#1512 DOORPs)."

0/1 · unit" of #1226 · 0/1

Page 41 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 41 · click to enlarge
Page 41
5. Base Specifications Parameters

# Items Details Setting range (unit)

1155 DOOR_m Signal input device 1 for door interlock II

Set up a fixed device number (X??) for door interlock II signal input. A device number from X001 to X3FF can be set up. Device number 000 is invalid. Set up device number 100 when using no fixed device number for door interlock II signal input. (Note) The setting range of this parameter has been

000 to 3FF (hexadecimal)

expanded on the software Ver.D0 and later. Related parameter: "#1154 pdoor" Door interlock II

(for each part system)

1156 DOOR_s Device number 2 for door interlock II signal input

Set up a fixed device number (X??) for door interlock II signal input. (Set up the same value as that of #1155.) (Note) The setting range of this parameter has been

000 to 3FF (hexadecimal)

expanded on the software Ver.D0 and later. Related parameter: "#1154 pdoor" Door interlock II

(for each part system)

1157 F0atrn F0 automatic running

Not used.

1158 F0atno F0 automatic running program

Not used.

1166 fixpro Fixed cycle editing

Select whether to use the edit‚ program list‚ and data input/output functions for the fixed cycle or general program.

0. Editing‚ etc.‚ of general program will be possible. 1: Editing‚ etc.‚ of fixed cycle will be possible.

1167 e2rom Not used.

1168 test Simulation test

Specify the test mode for the control unit. The test mode does not use reference point return‚ and tests with a hypothetical reference point return completed state. This is limited to test operation of the control unit itself‚ and must not be used when connected to the machine.

0. Normal operation mode 1: Test mode

0/1

Page 42 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — A, B, C
Page 42 · click to enlarge
Page 42
5. Base Specifications Parameters

# Items Details Setting range (unit)

Set the name of each part system. This must be set when using the multiple part system. This name is displayed on the screen only when the part systems must be identified. Use a max. of four alphabetic characters or numerals.

A max. of four alphabetic characters or numerals.

1170 M2name Second miscellane- ous code

Set this address code when using the 2nd miscellane- ous command. Set an address with A‚ B and C that is not used with "#1013 axname" or "#1014 incax".

A, B, C

1171 taprov Tap retract override

Set the tap retract override value for the synchronous tap.

1172 tapovr Tap retract override

Set the override value when leaving the tap end point in the synchronous tap cycle. The setting range is 1 to 999‚ and the unit is %. When a value less than 100 is set‚ it will be judged as 100%.

1173 dwlskp G04 skip condition

Specify the skip signal for ending the G04 (dwell) command.

Skip signals Setting SKIP3 SKIP2 SKIP1 SKIP0 0 × 1 × × × { 2 × × { × 3 × × { { 4 × { × × 5 × { × { 6 × { { × 7 × { { { 8 { × × × 9 { × × { 10 { × { × 11 { × { { 12 { { × × 13 { { × { 14 { { { × 15 { Skip when { signal is input.

1174 skip_F G31 skip speed

Specify the feedrate when there is no F command in the program at G31 (skip) command.

1 to 999999 (mm/min)

1169 system name · Part system name

Page 43 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 43 · click to enlarge
Page 43
5. Base Specifications Parameters

# Items Details Setting range (unit)

1175 1176 1177 1178 1179 1180

skip1 1f 2 2f 3 3f

Specify the skip signal in the G31.1 to G31.3 (multi-step skip) command‚ and the feedrate when there is no F command in the program.

Skip condition:

0 to 15 Skip federate:

Skip signals Setting SKIP3 SKIP2 SKIP1 SKIP0 0 × 1 × × × { 2 × × { × 3 × × { { 4 × { × × 5 × { × { 6 × { { × 7 × { { { 8 { × × × 9 { × × { 10 { × { × 11 { × { { 12 { { × × 13 { { × { 14 { { { × 15 { Skip when { signal is input. Skip signal specified at G31.1 Skip feedrate at G31.1 Skip signal specified at G31.2 Skip feedrate at G31.2 Skip signal specified at G31.3 Skip feedrate at G31.3

1 to 999999 (mm/min)

G31.1 skip condition G31.1 skip speed G31.2 skip condition G31.2 skip speed G31.3 skip condition G31.3 skip speed

Page 44 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 44 · click to enlarge
Page 44
5. Base Specifications Parameters

# Items Details Setting range (unit)

1181 G96_ax Constant surface speed control

Specify the axis to be targeted for constant surface speed control.

0. Program specification will be invalidated‚ and the axis will always be fixed to the 1st axis. 1: 1st axis specification 2: 2nd axis specification 3: 3rd axis specification 4: 4th axis specification The program specification will be the priority for all settings other than 0.

1182 thr_F Thread cutting speed

Set the screw cut up speed when not using chamfering in the thread cutting cycle.

0 to 60000 (mm/min)

0. Cutting feed clamp feedrate 1 to 60000 mm/min: Set feedrate

1183 clmp_M M code for clamp

Set the M code for C-axis clamp in the hole opening cycle.

1184 clmp_D Dwelling time after output- ting M code for unclamp

Set the dwell time after outputting the M code for C-axis unclamp in the hole opening cycle.

0.000 to 99999.999 (s)

1185 1186 1187 1188 1189

spd_F1 spd_F2 spd_F3 spd_F4 spd_F5

F1 digit feedrate F1 F2 F3 F4 F5

Specify the feedrate for the F command in the F1-digit command ("#1079 F1 digit" is set to 1). Feedrate when F1 is issued (mm/min) Feedrate when F2 is issued (mm/min) Feedrate when F3 is issued (mm/min) Feedrate when F4 is issued (mm/min) Feedrate when F5 is issued (mm/min)

1 to 1000000 (mm/min)

s_xcnt (For L system only)

0. Disable inclined-axis control 1: Enable inclined-axis control 0/1

s_angl (For L system only)

Specify the inclination angle α of the oblique coordinate X' axis from the orthogonal coordinate system's X axis.

–80.000 to 80.000 (degree)

s_zrmv (For L system only)

Compensati on at reference point return

Specify whether to perform compensation for the base axis corresponding to the inclined axis at reference point return.

0. Performs compensation. 1: Does not perform compensation.

Validate inclined-axis control · Inclination angle · 0/1

Page 45 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 0: G43.1 1: G44.1
Page 45 · click to enlarge
Page 45
5. Base Specifications Parameters

# Items Details Setting range (unit)

1193 inpos Validate in-position check

Specify the deceleration confirmation method for the positioning command.

0. Command deceleration check 1: In-position check
0. Command deceleration check (Positioning is completed when the deceleration is completed with the acceleration/deceleration speed issued from the control unit.) 1: In-position check (Positioning is completed by detecting that the servo amplifier has reached within a set distance from the end point. The set distance is set in "#2224 SV024".)

1194 H_acdc Time constant 0 for handle feed

Specify the time constant for the manual handle feed.

0. Use time constant for G01 1: Time constant 0 (step)

1195 1196 1197 1198

Mmac Smac Tmac M2mac

Macro call for:

Specify the user macro M‚ S or T command macro call out. Macro call out with M command Macro call out with S command Macro call out with T command Macro call out with 2nd miscellaneous command

0. Invalid 1: Valid

M command S command T command Second miscellaneous code

Select the initial condition of spindle control after power is turned on.

0: G43.1 1: G44.1

0. 1st spindle control mode (G43.1) 1: 2nd spindle control mode (G44.1)

Set up acceleration and deceleration types when a rapid traverse command is issued

celeration and deceleration with inclination angle constant G0

0. Acceleration and deceleration (conventional) with time constant 1: Acceleration and deceleration with inclination angle constant

Set up acceleration and deceleration types when a liner interpolation command is issued.

celeration and deceleration with inclination constant G1

0. Acceleration and deceleration (conventional) with time constant 1: Acceleration and deceleration with inclination angle constant

1202 mirofs (For L system only)

Distance between facing turrets

Set up the distance between tools (noses) (between turrets).

0 to 99999.999 (mm)

Show 7 more labels / short text on this page
0/1 · Sselect Select initial · spindle control · G0_acc Validate ac- · 0/1 · G1_acc Validate ac- · 0/1
Page 46 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 46 · click to enlarge
Page 46
5. Base Specifications Parameters

# Items Details Setting range (unit)

1203 TmirS1 (For L system only)

Select turrets for double-turret mirror image with T command

Set up turrets for double-turret mirror image with the T command that corresponds to tool numbers 1 to 32.

1204 TmirS2 (For L system only)

Select turrets for double-turret mirror image with T command

Set up turrets for double-turret mirror image with the T command that corresponds to tool numbers 33 to 64.

1205 G0bdcc Acceleration and deceleration before G0 interpolation

0. G00 acceleration and deceleration are selected as those after interpolation regardless of high-accuracy mode. 1: G00 acceleration and deceleration are selected as those before interpolation.

1206 G1bF Maximum speed

Set up a cutting feedrate when selecting acceleration and deceleration before interpolation.

1 to 1000000 (mm/min)

1207 G1btL Time constant

Set up a cutting feed time constant when selecting acceleration and deceleration before interpolation.

1 to 5000 (ms)

1208 RCK Arc radius error compen- sation factor

An arc radius error compensation amount can be increased and decreased from −60.0 to 20.0%.

1209 cirdcc Arc deceleration speed

Specify the deceleration speed at the arc entrance or exit.

1 to 1000000 (mm/min)

Show 7 more labels / short text on this page
0 to FFFFFFFF · 0 to FFFFFFFF · 0/1 · Speed · G1bF · Time · G1btL
Page 47 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 47 · click to enlarge
Page 47
5. Base Specifications Parameters

# Items Details Setting range (unit)

1210 RstGmd Modal G code reset

Specify whether to initialize each G code group modal and the H and D codes when the system is reset. Specify the initialization items in bit correspondence. 0. Initialize. 1: Do not initialize. M system

Specify a hexadecimal number.

0 Group 1 Move G modal 1 Group 2 Flat selection modal 2 Group 3 Absolute/increment command modal 3 4 Group 5 Feed G modal 5 Group 6 Inch/metric modal 6 Group 7 Radius compensation modal 7 Group 8 Length compensation modal 8 9 Group 10 Fixed cycle return command modal A B Group 12 Workpiece coordinate system modal C Group 13 Cut modal D E F

10 Group 17 Constant surface speed control command modal 11 12 Group 19 G command mirror modal 13 Group 20 Spindle 2 control modal 14 15 16 17 18 H, D codes 19 1A 1B 1C 1D 1E 1F

The H code indicates the tool length offset number, and the D code indicates the tool radius compensation number. When bit 18 is set to on, the H and D codes and group 8 G modal area retained. When bit 7 is set to on, the H code and group 8 G modal are retained.

Page 48 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 48 · click to enlarge
Page 48
5. Base Specifications Parameters

# Items Details Setting range (unit)

1210 RstGmd Modal G code reset

Specify a hexadecimal number.

0 Group 1 Move G modal 1 Group 2 Flat selection modal 2 Group 3 Absolute/increment command modal 3 Group 4 Barrier check modal 4 Group 5 Feed G modal 5 Group 6 Inch/metric modal 6 Group 7 Nose radius compensation modal 7 8 9 Group 10 Fixed cycle return command modal A B Group 12 Workpiece coordinate system modal C Group 13 Cut modal D E F

10 Group 17 Constant surface speed control command modal 11 Group 18 Balance cut 12 13 Group 20 Spindle 2 control modal 14 Group 15 Double-turret mirror image 15 16 17 18 19 1A 1B 1C 1D 1E 1F

1211 FHtyp Feed hold stop type

Specify the type of the external signal used for feed hold.

0. Disable the external signal. 1: Enable the external signal (contact A) 2: Enable the external signal (contact B)

1212 FHno Feed hold external signal device

Specify the number (X??) of the device used to input the feed hold signal. (Note) The setting range of this parameter has been

000 to 3FF (hexadecimal)

expanded on the software Ver.D0 and later.

1216 extdcc External deceleration level

Use an upper limit value at the feedrate indicated when validating external deceleration signals.

1 to 1000000 (mm/min)

1217 aux01 Not used.

L system

Page 49 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 49 · click to enlarge
Page 49
5. Base Specifications Parameters

# Items Details Setting range (unit)

Specify a parameter input/output format.

0. Type I 1: Type II

Specify the R register that contains the tool number used for automatic calculation when measuring the coordinate offset of an external work piece.

0. Conforms to "#1130 set_t". 1: Uses the tool number indicated by user PLC

Parameter I/O II spindle specification address

Specify the spindle specification address of parameter I/O type II.

0. C 1: T This parameter also applies to the spindle specification address for input and collation. (Note) This parameter is valid only for parameter I/O

type II ("#1218 aux02/bit 3" is 1).

Set No. valid when program input

Specify which program No. is selected when inputting operation using “#1 MAIN PROGRAM” in Data I/O screen.

0. The No. in the input data is valid. 1: The No. set in the data setting area is valid.

Input by program overwrite

When inputting the machining program in the "Data input" screen, select one of the following options when the input program has already been registered:

0. Outputs error message "E65 PROG. No. DUPLI" 1: Input by overwrite

Stop high- speed PC monitoring function

Set 1 to disable the function that stops the system when the high-speed processing time is extended. Disable the monitoring function only as a temporary measure.

Improve skip coordinate accuracy

0. Skip accuracy (conventional specification) 1: Changes skip accuracy (correct a position in skip coordinates when entering skip signals).

Reserved for the system. 0

Show 17 more labels / short text on this page
1218 aux02 (bit3) · Parameter input/output format · 0/1 · aux02 (bit4) · Tool number selection · 0/1 · aux02 (bit5) · 0/1 · aux02 (bit6) · 0/1 · aux02 (bit7) · 0/1 · 1219 aux03 (bit1) · 0/1 · aux03 (bit2) · 0/1 · aux03 (bit3)
Page 50 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 50 · click to enlarge
Page 50
5. Base Specifications Parameters

# Items Details Setting range (unit)

Time constant setting changeover for software acceleration/ deceleration

0. Accelerating time is G0tL(G1tL). If the time is set to the software acceleration/deceleration 2nd step time constant (#2005 G0t1) under such condition as the acceleration/deceleration before G00 interpolation and the software acceleration/deceleration are used one together, the inclination at software acceleration/deceleration will be steeper. Thus, the acceleration for G28/G30 will be larger than that for G00.
1. Total accelerating time is “G0L”. 2. The time for curve part is “G0t1”. 3. The time for linear part is obtained by “G0tL-(2 U G0t1)”. (Continued on the next page)
Show 10 more labels / short text on this page
aux03 (bit7) · 0/1 · Speed · t · G0tL-G0tl · G0tL · Acceleration · t · G0tl · G0tl
Page 51 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 51 · click to enlarge
Page 51
5. Base Specifications Parameters

# Items Details Setting range (unit)

(Continued from the previous page) 1: Accelerating time is obtained by G0tL+G0t1 (G1tL+G1t1). When the acceleration/deceleration before G00 interpolation and the software acceleration/deceleration are used one together, if the same time is set to S-curve filter time (#1131 F1dcc) and the software acceleration/deceleration 2nd step time constant (#2005 G0t1), the G00 acceleration can be obtained equals as G28/G30.

1. Total accelerating time is obtained by “G0tL+G0t1”. 2. The time for curve part is “G0t1”. 3. The time for linear part is obtained by “G0tL-G0t1”. (Note) This parameter is valid on the software Ver.C3

and later.

1220 aux04 (bit 0) (For L system only)

Tool life check timing selection

Specify the life check standard applicable when the use count is incremented in tool life management II.

0/1 (Default0)
0. Determines that the tool life is over when the incremented use count exceeds the life count. (Use count > life count)
1. Determines that the tool life is over when the incremented use count has reached the life count. (Use count ≥ life count)
Show 8 more labels / short text on this page
Speed · t · G0tL · Acceleration · G0tL+G0t1 · t · G0t1 · G0t1
Page 52 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 52 · click to enlarge
Page 52
5. Base Specifications Parameters

# Items Details Setting range (unit)

Validity of space code in comment

Validate or invalidate the space code described in the comment statements in the machining program in edit operation with the custom display.

0/1 (Default0)
0. Invalidate the space code in the comment statements of the machining program. 1: Validate the space code in the comment statements of the machining program.

1221 aux05 Not used.

Not used. 0

Not used. 0

Enable/disable setup parameter lock

Specify whether to enable the setup parameter lock function.

0. Disable 1: Enable

Not used. 0

Not used. 0

Not used. 0

Not used. 0

Not used. 0

Not used. 0

Not used. 0

Cancel synchronous tap (,S) retract

0. Retains a spindle rotation speed (, S) when performing synchronous tap retract. 1: Cancels a spindle rotation speed (, S) by retract with G80.

Specify a synchronous tap method.

0. Synchronous tap (multi-step acceleration and deceleration and rapid return) 1: Conventional type synchronous tap

1224 aux08 Unusable. Set 0 for this option.

Enable/disable spindle rotation clamp

Specify whether to enable spindle rotation clamp by the spindle rotation clamp command (G92S, Q) instead of the spindle rotation command (R3210) specified by the user ladder.

0. Enable 1: Disable
Show 19 more labels / short text on this page
1220 aux04 (bit1) · 1222 aux06 (bit0) · aux06 (bit1) · aux06 (bit3) · 0/1 · aux06 (bit7) · 1223 aux07 (bit0) · aux07 (bit1) · aux07 (bit2) · aux07 (bit3) · aux07 (bit4) · aux07 (bit5) · aux07 (bit6) · 0/1 · aux07 (bit7) · Synchronous tap method · 0/1 · 1225 aux09 (bit7) · 0/1
Page 53 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 53 · click to enlarge
Page 53
5. Base Specifications Parameters

# Items Details Setting range (unit)

Tool compen- sation data for external workpiece coordinate offset measurement

Select the tool offset data to be used for external workpiece coordinate offset measurement.

0. Tool length data and nose wear data 1: Tool length data

Optional block skip type

Specify whether to enable optional block skipping in the middle of a block.

0. Enable block skipping only at the beginning of a block. 1: Enable block skipping at the beginning of the block and in the middle of a block.

Single block stop timing

Specify the time at which the single block signal is activated.

0. When the signal goes on while automatic operation is starting, the block stops after it is finished. 1: When the signal is on at the end of the block, the block stops.

Not used. 0

S command during constant surface speed

Specify whether to output a strobe signal when the S command is issued in constant surface speed mode.

0. Output no strobe signal in constant surface speed mode. 1: Output strobe signals in constant surface speed mode.

Dog/OT signal arbitrary assignment valid

Specify whether to enable the arbitrary allocation parameter for the origin dog and H/W OT.

0. Disable arbitrary allocation. (Fixed devices are valid.) Note that when the backup module for powerfailure is mounted, all dog signals allocation will be disabled, however, OT signals will be allocated to the fixed devices. 1: Enable arbitrary allocation. (Devices specified by #2073 to #2075 parameters)
Show 11 more labels / short text on this page
1226 aux10 (bit0) · 0/1 · aux10 (bit1) · 0/1 · aux10 (bit2) · 0/1 · aux10 (bit3) · aux10 (bit4) · 0/1 · aux10 (bit5) · 0/1
Page 54 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 54 · click to enlarge
Page 54
5. Base Specifications Parameters

# Items Details Setting range (unit)

Setup and display unit

Specify the unit to be used as the setup/display unit or handle feed unit, the command unit or internal unit.

0. Internal unit 1: Unit specified by command (Note 1) This parameter is valid only in initial millimeter

mode (0 is set in "#1041 I_inch"). The internal unit is always used in initial inch mode (1 is set in "#1041 I_inch"). (Note 2) This parameter is validated immediately after

it is set. (Note 3) If addition setting is performed for tool and

workpiece offset data with the command unit being inch and internal unit being mm, an error may be generated. Related parameter: #1152 I_G20 (Initial command

Shorten JOG stop time

Specify whether to shorten the JOG stop time.

0. Do not shorten the JOG stop time. (Same as before) 1: Shorten the JOG stop time.

Select PLC signal or spindle feedrate attained

Set up this option when disabling the cutting start interlock by spindle feedrate attained.

0. Cutting start interlock by PLC signal 1: Cutting start interlock by spindle feedrate attained

Select H or D code

Set up this option to validate the data that is set up on the tool life management screen when issuing the H99 or D99 command.

0. The H and D codes validate the data that is set up on the management setup screen. 1: Validates the data that is set up on the management setup screen when issuing the H99 or D99 command.
Show 9 more labels / short text on this page
1226 aux10 (bit6) · 0/1 · unit) · aux10 (bit7) · 0/1 · 1227 aux11 (bit0) · 0/1 · aux11 (bit1) · 0/1
Page 55 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 55 · click to enlarge
Page 55
5. Base Specifications Parameters

# Items Details Setting range (unit)

Measures against tool setter chattering

Select a condition where a relieving operation completes after measurement with tools.

0. Sensor signals have stopped for 500 ms or longer. 1: 100 µ s or longer has passed after sensor signals stopped.

Absolute coordinate switching (nose R)

Select whether to display a nose position or coordinate value with the absolute coordinate counter.

0. Displays the nose position. 1: Displays the position specified by program command.

Specify whether to simply check the program address when the machining program is executed.

0. Does not check the program address. 1: Checks the program address.

Spindle rotation speed clamp

Specify whether to clamp the rotation speed in constant surface speed mode when the spindle rotation clamp command is issued.

0. Clamps the rotation regardless of the constant surface speed mode. 1: Clamps the rotation only in constant surface speed mode.

Not used. 0

Switch the range of tool life data to be input

Set up the range of tool life data to be input or compared.

0. Inputs or compares all of the data output. 1: Inputs or compares part of the data output 1) Tool life management I data to be input or compared tool number (D), lifetime (E), life count (F), and auxiliary data (B). 2) Tool life management II data to be input or compared Group number (G), method (M), life (E/F), tool number (D), and compensation number (H)
Show 12 more labels / short text on this page
1227 aux11 (bit2) · 0/1 · aux11 (bit3) · 0/1 · aux11 (bit4) · Program address check · 0/1 · aux11 (bit5) · 0/1 · aux11 (bit6) · aux11 (bit7) · 0/1
Page 56 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 56 · click to enlarge
Page 56
5. Base Specifications Parameters

# Items Details Setting range (unit)

Switch coordinate value screen

Set up this option to switch the coordinate value screen.

0. 80-character screen 1: 40-character screen

Switch offset and parameter screen

Set up this option to switch the offset and parameter screen to the parameter screen.

0. Displays the offset and parameter screen. 1: Displays the parameter screen.

Switch data protection in data transmission mode

Set up the range of data protection in data transmission mode.

0. Protects both send and receive data. 1: Protects receive data only.

Select whether to specify the nose R compensation by shape or wear number.

0. Specifies the nose R compensation by shape number. 1: Specifies the nose R compensation by wear number.

Select operation error or stop code

Specify both block cutting start interlock and cutting start interlock as the operation error or stop code.

0. Operation error 1: Stop code

Select constant surface speed coordinates

Select constant surface speed coordinates.

0. Workpiece coordinate value 1: Absolute coordinate value

Switch relative values displayed

0. Includes coordinate preset amounts in relative values (absolute values). 1: Does not coordinate preset amounts in relative values (absolute values).

Protection with manual value command

Set up this option to protect a manual value command.

0. Does not protect the manual value command (same as before). 1: Protects the manual value command.
0. Specifies the user macro interrupt of macro type. 1: Specifies the user macro interrupt of sub-program type.

Accurate thread cutting E

0. Address E specifies the number of threads per inch for inch screw cutting. 1: Address E specifies precise reading for inch screw cutting.
Show 22 more labels / short text on this page
1228 aux12 (bit0) · 0/1 · aux12 (bit1) · 0/1 · aux12 (bit2) · 0/1 · aux12 (bit3) · Nose R specification · 0/1 · aux12 (bit4) · 0/1 · aux12 (bit5) · 0/1 · aux12 (bit6) · 0/1 · aux12 (bit7) · 0/1 · 1229 set01 (bit0) · Subprogram interrupt · 0/1 · set01 (bit1) · 0/1
Page 57 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 57 · click to enlarge
Page 57
5. Base Specifications Parameters

# Items Details Setting range (unit)

Radius compen- sation type B (For M system only)

0. When the start-up and cancel commands are operated during radius compensation, their blocks are not handled by intersection operation processing; they are handled as offset vectors in the direction vertical to that of the commands. 1: When the start-up and cancel commands are operated during radius compensation, the intersection operation processing of the command block and the next block is executed.

Nose R compen- sation type B (For L system only)

0. When the start-up and cancel commands are operated during nose R, their blocks are not handled by intersection operation processing; they are handled as offset vectors in the direction vertical to that of the commands. 1: When the start-up and cancel commands are operated during nose R, the intersection operation processing of the command block and the next block is executed.

Initial constant surface speed

0. The initial state after power-on is a constant surface speed control cancel mode. 1: The initial state after power-on is a constant surface speed control mode.
0. Handles the tap cycles as the tap cycles with a floating tap chuck. 1: Handles the tap cycles as the tap cycles without a floating tap chuck.

Select an operation when the operation start point cannot be found while moving the next block of G117.

0. Enables an auxiliary function after the block has been moved. 1: Outputs a program error (P33) when the operation start point is not found.

Select a grid type to be displayed on the servo monitor screen during dog type reference point return.

0. Selects the distance between dog ON and reference point (including a grid mask amount). 1: Selects a value given by reducing a grid mask amount from the distance between dog ON and reference point.

1230 set02 Not used.

1231 set03 Not used.

1232 set04 Not used.

1233 set05 Not used.

Show 14 more labels / short text on this page
1229 set01 (bit2) · 0/1 · 0/1 · set01 (bit3) · 0/1 · set01 (bit4) · Synchronous tap · 0/1 · set01 (bit5) · Start point alarm · 0/1 · set01 (bit6) · Grid display selection · 0/1
Page 58 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 58 · click to enlarge
Page 58
5. Base Specifications Parameters

# Items Details Setting range (unit)

1234 set06 Not used.

1235 set07 Not used.

Manual rotation axis feedrate unit

Select the unit of manual rotation axis feedrate.

0. Fixed to [°/min] 1: Same speed as before

Set up this function to use the external workpiece coordinates by shifting them to the Z axis.

0. Does not reverse the sign of external workpiece offsets (Z shift) (same as before). 1: Reverses the sign of external workpiece offsets (Z shift). (Note) When the sign of external workpiece offsets (Z

shift) has been reversed, do not measure those external workpiece offsets. However, the external workpiece offsets can be measured by tool pre-setter.

set10 Not used.

0. Via PLC. (YD3F) 1: NC internal processing. (YD3F is invalid.) (Note) As for C6/C64/C64T, always set “1” when

using MDS-B-SP and later. However, if the system structure needs the mechanical gears for spindles, set “0”.

Select the handle input pulse.

0. MELDAS standard handle pulse 1: Handle 400 pulse

Megatorque motor handle feed magnifi- cation

Select the magnification of megatorque motor handle 1 pulse.

0. Double the handle 1 pulse magnification specified by the handle feed magnification signal (Y780, Y781, Y782). 1: Use the handle 1 pulse magnification specified by the handle feed magnification signal (Y780, Y781, Y782) as is.
Show 13 more labels / short text on this page
1236 set08 (bit0) · 0/1 · set09 (bit0) · External workpiece offset · 0/1 · set11 (bit0) · Coil switching method · 0/1 · set12 (bit0) · Handle input pulse · 0/1 · set12 (bit1) · 0/1
Page 59 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 59 · click to enlarge
Page 59
5. Base Specifications Parameters

# Items Details Setting range (unit)

Select the command format.

0. Conventional format 0

ext02 Not used.

G code type Select the G code type. This parameter is valid when 1 is set in "#1265 ext01 bit 0 (command format)".

ext04 Not used.

ext05 Not used.

ext06 Not used.

Select the type of mirror image operation. Not applied to this CNC.

0/1 (Default0)
  • 0: Type 1
  • The program mirror image, external mirror image, and parameter mirror image are exclusive to each other.
  • An increment command moves the image to the position indicated by the move amount with the sign inverted. 1: Type 2
  • Mirror image operation is enabled when the program mirror image (G51.1) command is issued or when the external signal or parameter is ON.
  • An increment command moves the image to the position determined by applying the mirror image to the absolute program coordinates.

Address specifying fixed-cycle repetition count (For M system only)

Specify the address that specifies the fixed-cycle repetition count. Not applied to this CNC.

0/1 (Default0)
0. Address L only 1: Addresses K and L If addresses K and L are specified simultaneously, the data at address K is used for operation.

Specify the unit to be used if a thread cutting read command contains on decimal point. Not applied to this CNC.

0/1 (Default0)
0. Type 1 (conventional specifications) F1 → 1 mm/rev, 1 inch/rev 1: Type 2 F1 → 0.01 mm/rev, 0.0001 inch/rev
Show 9 more labels / short text on this page
ext01 (bit0) · Command format · ext03 (bit0) · 0/1 · ext07 (bit0) · Mirror image operation · ext07 (bit1) · ext07 (bit2) · F-command unit
Page 60 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 60 · click to enlarge
Page 60
5. Base Specifications Parameters

# Items Details Setting range (unit)

G-code group for unidirectiona l positioning (for M system only)

Specify the G-code group for unidirectional positioning. Not applied to this CNC.

0. Unmodal G code (group 00) 1: Modal G code (group 01) Related parameter:

”#8209 G60 SHIFT”(Set the last positioning direction and distance for each axis applicable when the unidirectional positioning command is issued.)

Operation by independent G40 command

Specify the mode of canceling tool radius compensation vector by the independent G40 command. Not applied to this CNC.

0/1 (Default0)
0. Type 1 (conventional specifications) The independent G40 command cancels the tool radius compensation vector. 1: Type 2 The tool radius compensation vector is not canceled by the independent G40 command but is canceled by the next move command for the tool radius compensation plane.

Cut start position (For L system only)

Specify the position from where cutting begins in a composite-type fixed cycle for lathe.

0/1 (Default0)
0. Conventional specifications The cut start position is determined by the final shaping program. 1: Extended specifications The cut start position is determined from the cycle start point.

Nose R compensa- tion (For L system only)

Specify whether to apply nose R compensation to shapes in a rough cutting cycle.

0/1 (Default0)
0. Conventional specifications If nose R compensation is enabled for the final shaping program, the shape obtained after applying nose R compensation to the final shaping program is used as the rough cutting shape. 1: Extended specifications The shape made by the final shaping program, without nose R compensation, is used as the rough cutting shape.
Show 5 more labels / short text on this page
ext07 (bit3) · 0/1 · ext07 (bit4) · ext07 (bit5) · ext07 (bit6)
Page 61 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 61 · click to enlarge
Page 61
5. Base Specifications Parameters

# Items Details Setting range (unit)

Cut amount (For L system only)

Specify the operation to be performed when the program-specified cut amount exceeds the cut amount of the final shaping program.

0/1 (Default0)
0. Conventional specifications A program error occurs if the program-specified cut amount exceeds the cut amount of the final shaping program. 1: Extended specifications Rough cutting is performed by one cut if the program-specified cut amount exceeds the cut amount of the final shaping program.

M function synchronous tap cycle

Specify whether to enable the M function synchronous tap cycle.

0. Disable 1: Enable

ext09 Not used.

ext10 Not used.

ext11 Not used.

ext12 Not used.

Tool life management II count type 2

Specify how and when the mount or use count is incremented in tool life management II.

0/1 (Default0)
0. Type 1 The count is incremented when the spindle is used for cutting. 1: Type 2 The count is incremented for the tool used or mounted for one program. The increment is enabled by resetting.

ext14 Not used.

ext15 Not used.

ext16 Not used.

ext17 Not used.

ext18 Not used.

ext19 Not used.

ext20 Not used.

ext21 Not used.

Show 4 more labels / short text on this page
ext07 (bit7) · ext08 (bit1) · 0/1 · ext13 (bit0)
Page 62 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 62 · click to enlarge
Page 62
5. Base Specifications Parameters

# Items Details Setting range (unit)

ext22 Not used.

Select the mode of displaying the workpiece coordinate counter.

0. Does not update the display immediately after workpiece coordinate data is changed. 1: Updates the display immediately after workpiece coordinate data is changed.
0. Displays the actual position including tool length compensation. 1: Displays the machining position in terms of a program command excluding tool length compensation. (L system)
0. Displays the actual position including tool shape compensation. 1: Displays the machining position in terms of a program command excluding tool shape compensation.
0. Displays the actual position including tool radius compensation. 1: Displays the machining position in terms of a program command excluding tool radius compensation. (L system)
0. Displays the actual position including nose R compensation. 1: Displays the machining position in terms of a program command excluding nose R compensation.
0. Displays the actual position including tool length compensation. 1: Displays the machining position in terms of a program command excluding tool length compensation. (L system)
0. Displays the actual position including tool shape compensation. 1: Displays the machining position in terms of a program command excluding tool shape compensation.
Show 15 more labels / short text on this page
ext23 (bit0) · Workpiece coordinate display · 0/1 · ext23 (bit4) · Relative coordinate display · (M system) · 0/1 · ext23 (bit5) · Relative coordinate display · (M system) · 0/1 · ext23 (bit6) · Absolute coordinate display · (M system) · 0/1
Page 63 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 63 · click to enlarge
Page 63
5. Base Specifications Parameters
Mitsubishi Electronics CNC Controller Board (C64) — 5. Base Specifications Parameters diagram (page 63)
Fig. 23 · 5. Base Specifications Parameters
0. Displays the actual position including tool radius compensation. 1: Displays the machining position in terms of a program command excluding tool radius compensation. (L system)
0. Displays the actual position including nose R compensation. 1: Displays the machining position in terms of a program command excluding nose R compensation.
0. Spindle synchronous control II (Controlled by PLC I/F) 1: Spindle synchronous control I (Controlled by G code)
Page 64 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 64 · click to enlarge
Page 64
5. Base Specifications Parameters

# Items Details Setting range (unit)

1301 nrfchk Origin neighboring check method

Select the high-speed check method of the origin neighboring signal.

0. Does not check positions near the origin at high speeds. (Conventional specifications) 1: Checks positions near the origin at high speeds using command machine positions. 2: Checks positions near the origin at high speeds using detector feedback positions.

1501 polyax (For L system only)

Rotational tool axis number

Specify the number of the rotational tool axis (servo axis) used for polygonal machining (G51.1). Specify 0 when polygonal machining is not performed. A value exceeding the base specification parameter "#1002 axisno" cannot be specified. This parameter is valid when the G code system is 6 or 7 (7 or 8 is set in base specification parameter "#1037 cmdtyp").

0 to controlled axis number

1505 ckref2 Second reference point return check

Specify the trigger for a check at the specified position in manual second reference point return mode.

0. Completion of spindle orientation 1: Generation of second reference point return interlock signal

1510 DOOR_H Shorten door interlock II axis stop time

Specify whether to shorten the time during which the axis is stopped when the door is opened.

0. Uses the conventional axis stop time. 1: Shortens the axis stop time. (Note) When the door interlock II signal is input via a

ladder, the conventional axis stop time is used.

1511 DOORPm Signal input device 1 for door interlock II: for each part system

Specify the fixed device number (X??) for door interlock II signal input for each part system. A device number from X001 to X3FF can be specified. Device number 000 is invalid. Specify device number 100 when using no fixed device number for door interlock II signal input. (Note) The setting range of this parameter has been

000 to 3FF (hexadecimal)

expanded on the software Ver.D0 and later. Related parameter: #1154 pdoor (Door interlock II for

1512 DOORPs Signal input device 2 for door interlock II: for each part system

Specify the fixed device number (X??) for door interlock II signal input for each part system. (Specify the same value as that of #1155.) (Note) The setting range of this parameter has been

000 to 3FF (hexadecimal)

expanded on the software Ver.D0 and later. Related parameter: #1154 pdoor (Door interlock II for

Show 4 more labels / short text on this page
0/1 · 0/1 · each part system) · each part system)
Page 65 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 65 · click to enlarge
Page 65
5. Base Specifications Parameters
Mitsubishi Electronics CNC Controller Board (C64) — 5. Base Specifications Parameters diagram (page 65)
Fig. 24 · 5. Base Specifications Parameters

+99999999 1802 Macc_c Acceleration check at middle speed -99999999 to

+99999999 1803 Lacc_c Acceleration check at low speed -99999999 to

+99999999 1811 Hcof_A X-axis high acceleration coefficient β -99999999 to

+99999999 1812 Hcof_B X-axis high acceleration coefficient α -99999999 to

+99999999 1813 Mcof_A X-axis middle acceleration coefficient β -99999999 to

+99999999 1814 Mcof_B X-axis middle acceleration coefficient α -99999999 to

+99999999 1815 Lcof_A X-axis low acceleration coefficient β -99999999 to

+99999999 1816 Lcof_B X-axis low acceleration coefficient α -99999999 to

+99999999 1817 mag_C X-axis change magnification θ [%] Set 0 when no compensation or change is executed.

1821 Hcof_A Y-axis high acceleration coefficient β -99999999 to

+99999999 1812 Hcof_B Y-axis high acceleration coefficient α -99999999 to

+99999999 1813 Mcof_A Y-axis middle acceleration coefficient β -99999999 to

+99999999 1814 Mcof_B Y-axis middle acceleration coefficient α -99999999 to

+99999999 1815 Lcof_A Y-axis low acceleration coefficient β -99999999 to

+99999999 1816 Lcof_B Y-axis low acceleration coefficient α -99999999 to

+99999999 1817 mag_C Y-axis change magnification θ [%] Set 0 when no compensation or change is executed.

Page 66 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 66 · click to enlarge
Page 66
5. Base Specifications Parameters

# Items Details Setting range (unit)

station addr Set up a station address number (the NC is the n-th slave station).

Din size Set up the size of the data to be transferred from the PC to the NC (from the master station to the slave station) in bytes (8 points).

0 to 32 (bytes (8 bits))

Dout size Set up the size of the data to be transferred from the NC to the PC (from the slave station to the master station) in bytes (8 points).

0 to 32 (bytes (8 bits))

data length Set up the data length of a character. 0 to 2 : 7 bits 3 : 8 bits 1905 (PR)

Clock: 6/10 MHz 0: 38400 / 57600 1: 19200 / 28800 2: 9600 / 14400 3: 4800 / 7200 4: 2400 / 3600 5: 1200 / 1800 6: 600 / 900 (bps) 1906 (PR)

baud rate Set up a data transfer rate. The transfer rate differs according to operation clock rates.

stop bit Set up the stop bit length. 0 and 1: 1 bit 2 and 3: 2 bits 1907 (PR)

parity check Select whether to make a parity check. 0: Invalid 1: Valid 1908 (PR)

0. Odd parity 1: Even parity 1909 (PR)

even parity Select the odd or even parity bit. If no parity check is specified, this parameter is ignored.

Tout (ini) (ini) specifies a time-out from when the connection check sequence finishes to when the first usual sequence (input) finishes.

0 to 999 (0.1 s)

(run) (run) specifies a time-out from when the NC (slave station) outputs usual sequence data to when the next usual sequence data is input. If the time-out is exceeded, an emergency stop occurs and the system waits for the preparation sequence to start. If the set value is 0, no time-out occurs or no communi- cation stop can be detected.

clock select Select an operation cycle. 0: 6 MHz 1: 10 MHz 1926 (PR)

IP address Set NC's IP address.

Set these according to connection environ- ment's network regulations.

Subnet mask Set sub-net mask.

Gateway address Designate gateway IP address.

Page 67 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 67 · click to enlarge
Page 67
5. Base Specifications Parameters

# Items Details Setting range (unit)

Port number Set the HMI connection port No. (Set the default value 64758 unless particularly required.)

Speed 10M/auto Set the communication rate.

0. Fixed to “10Mbyte” 1: Recognized whether “10Mbyte” or “100Mbyte” automatically and set.

IP address(2) Set NC's IP address. Set for the card mounted on the 2nd channel when 2-channel connection is used on the Ethernet communication. (Note1) 1932 (PR)

Set these according to connection environ- ment's network regulations.

Subnet mask(2) Set sub-net mask. Set for the card mounted on the 2nd channel when 2-channel connection is used on the Ethernet communication. (Note1)

Port number(2) Set the HMI connection port No. (Set the default value 64758 unless particularly required.) Set for the card mounted on the 2nd channel when 2-channel connection is used on the Ethernet communication. (Note1)

Speed(2) 10M/auto Set the communication rate.

0. Fixed to “10Mbyte” 1: Recognized “10Mbyte” or “100Mbyte” automatically and set. Set for the card mounted on the 2nd channel when 2-channel connection is used on the Ethernet communication. (Note1)

(Note1) When two Ethernet cards are mounted, make sure not to use IP address on the same network

IDs. The cards are regarded as “same network IDs” when the area masked (validated) by “Subnet mask” parameter is the same as another.

0/1 · 0/1

Page 68 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 68 · click to enlarge
Page 68
5. Base Specifications Parameters

# Items Details Setting range (unit)

21025 SmpDelay Set up a sampling time after an alarm occurs. 0 to 3000 (ms) 21028 ed_mess Set up an edit type.

0. Displays messages with state. 1: Displays operation message equivalent to M50.

21029 NCname Use this to display the NC unit name on the CE terminal screen.

8 or less alphanumeric characters 21030 AlmHold (h) Set the time to delete sampling data automatically after an alarm occurs. If 0 is set, the alarm will not be deleted automatically.

0 to 9999 (h)

21031 UnitMax Set the number of connected control units when setting and displaying several NC control units with one terminal using the multiple NC common display function. Up to 15 NC control units can be connected. The default value is "0", so if the setting is not changed, it will be interpreted that 1 control unit is connected. (The setting values "0" and "1" are handled in the same manner.)

0 to 15 (Default value0)

21032 UnitNum Set the control unit's station No. when setting and displaying several NC control units with one terminal using the multiple NC common display function. "0" is the first station No. and "14" is the last station No. Make sure that the stations are not set in duplicate.

0 to 14 (Default value0)

21033 KeyCtrlLmt Acquisition of the key operation rights are limited.

0. The key operation rights can be acquired from another display unit on all screens. 1: The key operation rights cannot be acquired while the Program screen is opened. 2: The key operation rights cannot be acquired from another display unit on any screen.

21034 ReMonDisp The remote monitor tool displays are limited.

0. The remote monitor tool displays are not limited. 1: Display information is not sent to the remote monitor tool. (Note) Avoid setting from the remote monitor tool. The

display will not appear as soon as this parameter is set.

21049 SPname Designate the spindle No. selected for the G43.1 modal in each part system.

0. 1st spindle 4: 4th spindle 1: 1st spindle 5: 5th spindle 2: 2nd spindle 6: 6th spindle 3: 3rd spindle 7: 7th spindle

0/1

Page 69 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 69 · click to enlarge
Page 69
5. Base Specifications Parameters

# Items Details Setting range (unit)

PLC axis rapid traverse mode acceleration/ deceleration type

Select the PLC axis rapid traverse mode acceleration/ deceleration type. (This is compatible from software version C0 and higher.)

0. Select constant time constant acceleration/ deceleration 1: Select constant inclination acceleration/ deceleration (Note) This parameter cannot be used when the

peripheral axes (MC1K I/F) is used.

PLC axis cutting feed mode acceleration/ deceleration type /Peripheral axis (MC1K I/F) acceleration/ deceleration type

Select the PLC axis cutting feed mode acceleration/ deceleration type. (This is compatible from software version C0 and higher.)

0. Select constant time constant acceleration/ deceleration 1: Select constant inclination acceleration/ deceleration (Note) Select the peripheral axis (MC1K I/F)

acceleration/deceleration type when the peripheral axes are used. (This is compatible from software version C0 and higher.)

Circular command block overlap valid

Validates the block overlap at the circular command. (This is compatible from software version C1 and higher.)

0. Invalid 1: Valid

G31 automatic acceleration/ deceleration

Validates dry run, override and automatic acceleration/ deceleration for the G31 (skip) command. (This is compatible from software version C1 and higher.)

0. Invalid 1: Valid

Reserved for system. 0

Reserved for system. 0

Show 10 more labels / short text on this page
21101 add01 (bit0) · 0/1 · add01 (bit1) · 0/1 · add01 (bit2) · 0/1 · add01 (bit3) · 0/1 · add01 (bit4) · add01 (bit5)
Page 70 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 70 · click to enlarge
Page 70
5. Base Specifications Parameters

# Items Details Setting range (unit)

Servo parameter 100-point compliance

0. The number of servo parameters is set to 64 points. 1: The number of servo parameters is set to 100 points when using the 100-point servo parameter compliant amplifier. (This is compatible from software version C1 and higher.)

External search time-out valid

0. Time-out check of the external search command (DDBS) is not performed. 1: Time-out is performed approx. 3 seconds after the external search command (DDBS) is issued. (This is compatible from software version C2 and higher.)

RIO communi- cation interruption alarm invalid

0. The alarm “RIO communication interrupted” will occur if the remote I/O unit is not mounted. 1: Any alarm will not occur evenif the remote I/O unit is not mounted. Set “1” if the remote I/O unit is not used though CC-Link, MELSECNET/10, etc. is used. (This is compatible from software version C3 and higher.)

Reserved for system. 0

Amp S/W automatic download valid (only C64T)

Specify whether to perform or not the automatic download of the amp software when the power is turned ON.

0/1 (Standard:0)

0. Disables download 1: Enables download (This is compatible from software version C4 and higher.)

Select the sampling mode. (This is compatible from software version D0 and higher.)

0. Cycle monitor mode 1: NC alarm diagnosis mode When NC power is turned ON, cycle monitor mode is selected.
Show 11 more labels / short text on this page
21102 add02 (bit0) · 0/1 · add02 (bit1) · 0/1 · add02 (bit2) · 0/1 · 21103 add03 (bit0) · add03 (bit1) · 21104 add04 (bit0) · Sampling mode selection · 0/1
Page 71 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 5. Base Specifications Parameters
Page 71 · click to enlarge
Page 71
5. Base Specifications Parameters
Mitsubishi Electronics CNC Controller Board (C64) — 5. Base Specifications Parameters diagram (page 71)
Fig. 25 · 5. Base Specifications Parameters
Page 72 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 6.1 Axis Specifications Parameters
Page 72 · click to enlarge
Page 72
6. Axis Specifications Parameters 6.1 Axis Specifications Parameters

6. Axis Specifications Parameters

6.1 Axis Specifications Parameters

After setting up the parameter (PR) listed in the table, turn off the NC power. To validate the parameter, turn on the power again.

# Items Details Setting range

(unit) 2001 rapid Rapid traverse feedrate

Set up the rapid traverse feedrate for each axis. The maximum value to be set differs with mechanical systems.

1 to 1000000 (mm/min)

2002 clamp Cutting feedrate for clamp function

Define the maximum cutting feedrate for each axis. Even if the feedrate in G01 exceeds this value‚ the clamp will be applied at this feedrate.

1 to 1000000 (mm/min)

smgst Acceleration and deceler- ation modes

Specify acceleration and deceleration control modes.

Specify the modes in hexadecimal notation.

F E D C B A 9 8 7 6 5 4 3 2 1 0

OT3 OT2 OT1 C3 C1 LC R3 R1 LR

(Note) Set 0 in null bits. Rapid traverse feed acceleration and deceleration types

LRLinear acceleration/deceleration R1: Primary delay R3: Exponential acceleration and linear

deceleration (Note) Designate “F” with bits 0 to 3 for rapid traverse

with acceleration/deceleration by software. Note that the acceleration/deceleration by software will not applied on such case as follows;

(1) When the parameters are set as “#1205

G0bdcc” = “1” (acc/dec before G00 is valid) and “#1086 G0Intp” = “0” (G00 non-interpolation invalid), the acceleration/deceleration before interpolation will be applied to the following operation. (a) Travel by G00 command (b) Travel from G28/G30 command start

point to the intermediate point (c) Travel from G29 command reference

to the intermediate point (Continued on the next page)

Page 73 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 6. Axis Specifications Parameters
Page 73 · click to enlarge
Page 73
6. Axis Specifications Parameters 6.1 Axis Specifications Parameters

# Items Details Setting range

(unit) (Continued from the previous page) Cutting feed acceleration and deceleration types

LCLinear acceleration/deceleration C1: Primary delay C3: Exponential acceleration and linear

deceleration (Note) Designate “F” with bits 4 to 7 for cutting feed

with acceleration/deceleration by software. Note that the acceleration/deceleration by software will not applied on such case as follows;

(1) AS for G01/G02/G03 command during

G61.1 modal, s-curve acceleration/ deceleration before interpolation is applied to. (2) Linear acceleration/deceleration is applied

to the cutting feed during synchronous tapping.

Mitsubishi Electronics CNC Controller Board (C64) — 6. Axis Specifications Parameters diagram (page 73)
Fig. 26 · 6. Axis Specifications Parameters

R1 > R3 when both R1 and R3 contain 1.

(Continued on the next page)

Type OT2 OT3 Linear deceleration 0 0 Position loop step stop 1 0 Speed loop step stop 0 1 Position loop step stop 1 1 OT1 0 Deceleration by G0t1 1 Deceleration by 2 × G0t1

patterns>

Page 74 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — (0T1=1)
Page 74 · click to enlarge
Page 74
6. Axis Specifications Parameters 6.1 Axis Specifications Parameters

# Items Details Setting range (unit)

(Continued from the previous page)

(0T1=1)

OT1 is valid under the following conditions (valid for dog type reference point return): Stop type: Linear deceleration Acceleration mode: Exponential Deceleration mode: Linear

2004 G0tL G0 time constant (linear)

Set up a linear control time constant for rapid traverse acceleration and deceleration. The time constant is validated when LR (rapid traverse feed with linear acceleration or deceleration) or F (acceleration or deceleration by software) is selected in acceleration or deceleration mode "#2003 smgst."

1 to 4000 (ms)

Show 9 more labels / short text on this page
Stroke end signal · Speed · Time · G0t1 · G0t1 (0T1=0) · 2 G0t1 · Speed · Time · G0tL G0tL
Page 75 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 6. Axis Specifications Parameters
Page 75 · click to enlarge
Page 75
6. Axis Specifications Parameters 6.1 Axis Specifications Parameters

# Items Details Setting range (unit)

2005 G0t1 G0 time constant (primary delay) Second-step time constant for acceleration and deceleration by software

Set up a primary-delay time constant for rapid traverse acceleration and deceleration. The time constant is validated when R1 (rapid traverse feed with primary delay) or R3 (exponential acceleration and linear deceleration) is selected in acceleration or deceleration mode "#2003 smgst." When acceleration or deceleration by software is selected, the second-step time constant is used.

1 to 5000 (ms)

<Rapid traverse feed with primary delay>

<Rapid traverse feed with exponential acceleration and linear deceleration>

2006 G0t2 Not used. 0

Show 13 more labels / short text on this page
Speed · Time · G0t1 G0t1 · Speed · Time · G0t1 2 G0t1 · <Acceleration/deceleration by software> · Speed · Time · G0t1 G0t1 · G0t1 · G0t1 · G0tL G0tL
Page 76 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 6. Axis Specifications Parameters
Page 76 · click to enlarge
Page 76
6. Axis Specifications Parameters 6.1 Axis Specifications Parameters

# Items Details Setting range (unit)

2007 G1tL G1 time constant (linear)

Set up a linear control time constant for cutting acceleration and deceleration. The time constant is validated when LC (cutting feed with linear acceleration and deceleration) or F (acceleration and deceleration by software) is selected in acceleration or deceleration mode "#2003 smgst."

1 to 4000 (ms)

2008 G1t1 G1 time constant (primary delay) Second-step time constant for acceleration and deceleration by software

Set up the primary delay time constant for cutting acceleration and deceleration. The time constant is validated when C1 (cutting feed with the primary delay) or C3 (cutting feed with exponential acceleration and linear deceleration) is selected in acceleration or deceleration mode "#2003 smgst." When acceleration or deceleration by software is selected, the second stage time constant is used.

1 to 5000 (ms)

<Cutting feed with primary delay>

<Cutting feed with exponential acceleration and linear deceleration>

2009 G1t2 Not used.

Show 15 more labels / short text on this page
Speed · Time · G1tL G1tL · Speed · Time · G1t1 G1t1 · Speed · Time · G1t1 2 G1t1 · <Acceleration/deceleration by software> · Speed · Time · G1t1 G1t1 G1t1 · G1t1 · G1tL G1tL
Page 77 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — M
Page 77 · click to enlarge
Page 77
6. Axis Specifications Parameters 6.1 Axis Specifications Parameters

# Items Details Setting range (unit)

2010 fwd_g Feed forward gain

Set up a feed forward gain for pre-interpolation acceleration and deceleration. The larger the set value, the smaller the theoretical control error will be. However, if a mechanical vibration occurs, the set value must be reduced.

2011 G0back G0 backlash Set up the backlash compensation amount when the direction is reversed with the movement command in rapid traverse feed mode or in manual mode.

−9999 to 9999 (command unit / 2)

2012 G1back G1 backlash Set up the backlash compensation amount when the direction is reversed with the movement command in cutting mode.

−9999 to 9999 (command unit / 2)

2013 2014 0T − 0T + Soft limit I − Soft limit I +

Set up a soft limit area with reference to the zero point of the basic mechanical coordinates. For the movable area of stored stroke limit 1, set the coordinate in the negative direction in #2013 and the coordinate in the positive direction in #2014. To narrow the available range in actual use, use the parameters #8204 OT- and #8205 OT+. (Note) When the same value (other than 0) is set in

±99999.999 (mm)

#2013 and #2014, this function is disabled.

M

OT+(Z)

OT-(X)

OT+(X)

OT-(Z)

2015 t1m1− Negative direction sensor of tool setter or TLM standard length

Set up a sensor position in the negative direction when using the tool setter. When the TLM is used, set up the distance of a tool replacement point (reference point) for measuring the tool length from the zero point to the measurement reference point (surface).

±99999.999 (mm)

2016 t1m1+ Positive direction sensor of tool setter

Set up the sensor position in the positive direction when using the tool setter.

±99999.999 (mm)

Basic machine coordinate · Movable area

Page 78 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 6. Axis Specifications Parameters
Page 78 · click to enlarge
Page 78
6. Axis Specifications Parameters 6.1 Axis Specifications Parameters

# Items Details Setting range (unit)

2017 tap_g Axis servo gain

Set the position loop gain in the synchronous tap cycle. The setting range is 0.25 to 200.00rad/s‚ in 0.25 increment units. The standard setting is 10.

0.25 to 200.00 (rad/s)

2018 no_srv Operation with no servo control

Set when performing test operation without connecting the drive amplifier and motor.

0. Specify normal operation. 1: Operation is possible even if units are not connected as the drive system alarm will be ignored. This is for test operation during start up and is not used normally. If 1 is set during normal operation‚ errors will not be detected even if they occur.

2019 revnum Retract steps Set up the steps required for retracting to the reference point for each axis.

0. Does not execute retracting to the reference point. 1 to 4: Sets up the steps required for retracting to the reference point.

2020 o_chkp Spindle orientation completion check during second reference point return

Set up the distance from the second reference point to the position for checking that the spindle orientation has completed during second reference point return. If the set value is 0, the above check is omitted.

0 to 99999.999 (mm)

2021 out_f Maximum speed outside soft limit range

Set up the maximum speed outside the soft limit range. 0 to 1000000

2022 G30SLX Validate soft limit (automatic and manual)

Set up this function to disable a soft limit check during the second to the fourth reference points return in both automatic and manual operation modes.

0. Enables soft limit check. 1: Disables soft limit check.

2023 ozfmin Set up ATC speed lower limit

Set up the minimum speed outside the soft limit range during the second to the fourth reference points return in both automatic and manual operation modes.

2024 synerr Allowable error

Set up the following for the master axis: the maximum synchronization error that is allowed to check for synchronization errors. When 0 is set up, the error check is not carried out.

0 to 99999.999 (mm)

0/1 · 0/1

Page 79 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 6.2 Zero Point Return Parameters
Page 79 · click to enlarge
Page 79
6. Axis Specifications Parameters 6.2 Zero Point Return Parameters

6.2 Zero Point Return Parameters

After setting up the parameter (PR) listed in the table, turn off the NC power. To validate the parameter, turn on the power again.

# Items Details Setting range (unit)

2025 G28rap G28 rapid traverse feedrate

Set up a rapid traverse feedrate for dog type reference point return command.

1 to 1000000 (mm/min)

2026 G28crp G28 approach speed

Set up the speed of approach to the reference point in the reference point return command. This speed is attained after the system stops with deceleration by dog detection. (Note) The G28 approach speed unit is 10°/min only

1 to 60000 (mm/min)

when using the spindle/C-axis with the Z-phase type encoder for the reference point return type ("#1226 aux10" bit3 = 1). Note that this unit is applied to both micrometric and sub-micrometric specifications.

2027 G28sft Reference point shift distance

Set up the distance from the electrical zero-point detection position to the actual machine reference point during reference point return.

0 to 65535 (µm)

2028 grmask Grid mask amount

Set up a distance where the grid point is ignored when near-point dog OFF signals are close to that grid point during reference point return.

0 to 65535 (µm) Even for the specifications in sub-micrometric system, set up the value in units of µm.

Grid mask setup distance

The grid mask is valid by one grid.

2029 grspc Grid interval Set up a detector grid interval. Generally, set up the value equal to the ball screw pitch. However, if the detector grid interval is not equal to the screw pitch when measured with a linear scale, set up the detector grid interval. To reduce the grid interval, use its divisors. To use 0.001 mm as minimum setup units, set up the negative value. Example) Setup value

−32767 to 999 (mm)

−1 → 1.000 mm (°) −1 → 0.001 mm (°) Even when the specifications in sub-micrometrics are used, 0.001 mm is specified for the minimum setup units.

Near-point dog

Page 80 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 6.2 Zero Point Return Parameters
Page 80 · click to enlarge
Page 80
6. Axis Specifications Parameters 6.2 Zero Point Return Parameters

# Items Details Setting range (unit)

dir (−) Reference point direction (−)

Set which side of the near-point dog the reference point is at during reference point return.

0. Positive direction 1: Negative direction

Direction in which zero point is established as viewed from the near-point dog

2031 noref Axis without reference point

Specify the axis that does not have a reference point. Before automatic operation starts, reference point return is not required.

0. Normal controlled axis 1: Axis without reference point

2032 nochk Whether reference point return is completed not checked

The absolute and incremental commands can be executed even if dog type (or Z phase pulse system) reference point return is not completed. Specify whether to check that the reference point return is completed.

0. Checks reference point return completion. 1: Does not check reference point return completion.

2037 2038 2039 2040

G53ofs #2_rfp #3_rfp #4_rfp

Reference point #1 to #4

Set up the position of the first, second, third, and fourth reference points from the zero point of the basic mechanical coordinates.

±999999.999 (mm)

M Basic machine coordinates

Show 8 more labels / short text on this page
Negative direction · Positive direction · dir(-)=0 · dir(-)=1 · Reference point #1 · Reference point #2 · Reference point #3 · Reference point #4
Page 81 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 6.3 Absolute Position Parameters
Page 81 · click to enlarge
Page 81
6. Axis Specifications Parameters 6.3 Absolute Position Parameters

6.3 Absolute Position Parameters

# Items Details Setting range (unit)

type Absolute position detection method

Specify the absolute position zero point alignment method.

0. Not absolute position detection 1: Stopper method (push onto mechanical stopper) 2: Marked point alignment method (align with marked point) 3: Dog-type (align with dog and proximity switch) 9: Simple absolute position detection (Not absolute position detection‚ but the position when the power is turned off is registered.) Automatic initial setting is valid only when the stopper method is selected.

2050 absdir Base point of Z direction

Set the direction of the grid point just before the marked point (of the detector) when using marked point alignment method.

0. Positive direction 1: Negative direction

2051 check Check Set the tolerable range for the movement amount (deviation amount) when the power is turned off.

0 to 99999.999 (mm)

0. Not checked 1 to 99999.999mm: If the difference of the position when the power is turned off and turned on again is larger than this value‚ an alarm will be output.

2052 absg28 Width compared by G28

Specify the position comparison when executing G28 or G30. The comparison results set the tolerable range.

0 to 65535 (0.5 µm)

0. No comparison 1 to 65535 (0.5 µm units): If the results of the comparison of the value read in from the detector and the position in the control unit exceed this set value‚ an alarm will be output‚ and the machine will stop. The standard value is 100.

2053 absm02 Width compared by M02

Specify the position comparison when executing M02 or M30. The comparison results set the tolerable range.

0 to 65535 (µm)

0. Not compared 1 to 65535 (0.5 µ m units): If the results of the comparison of the value read in from the detector and the position in the control unit exceed this set value‚ an alarm will be output‚ and the machine will stop. The standard value is 100.
Page 82 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 6.3 Absolute Position Parameters
Page 82 · click to enlarge
Page 82
6. Axis Specifications Parameters 6.3 Absolute Position Parameters

# Items Details Setting range (unit)

2054 clpush Current limit (%)

Set up the current limit value for the initial setting when detecting an absolute position with a dog-less system. The setup value is the ratio of the current limit value to the rated value.

2055 pushf Push speed Set the feedrate for the automatic initial setting during stopper method.

1 to 999 (mm/min)

2056 aproch Approach Set the approach distance for the automatic initial setting in the stopper method. Approach distance: After pushing onto the machine

0 to 999.999 (mm)

stopper once‚ the tool returns this distance‚ and then pushes again. When set to 0‚ the reference point coordinates set in "#2037 G53ofs" will be used as the approach start position.

2057 nrefp Near zero point +

Set the width where the near-reference-point signal is output. (Positive direction width) When set to 0‚ the width is equivalent to the grid width setting.

0 to 32.767 (mm)

2058 nrefn Near zero point −

Set the width where the near-reference-point signal is output. (Negative direction width) When set to 0‚ the width is equivalent to the grid width setting.

0 to 32.767 (mm)

2059 zerbas Select zero point parameter and reference point

Specify the position to be the zero point coordinate during absolute position initial setting.

0. Machine stopper position in machine stopper method. Marked point in marked point alignment method. 1: On the grid point just before machine stopper in machine stopper. On the grid point just before the marked point in marked point alignment method.

0/1

Page 83 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 6.4 Axis Specifications Parameters 2
Page 83 · click to enlarge
Page 83
6. Axis Specifications Parameters 6.4 Axis Specifications Parameters 2

6.4 Axis Specifications Parameters 2

# Items Details Setting range (unit)

2061 OT_1B− Soft limit IB− Set up the coordinates of the lower limit of the inhibited area of stored stroke limit IB. Specify a value in the basic machine coordinates system. If the same value (other than 0) with the same sign as that of "#2062 OT_IB−" is specified, the stored stroke limit IB function is disabled.

±99999.999 (mm)

2062 OT_1B+ Soft limit IB+ Set up the coordinates of the upper limit of the inhibited area of stored stroke limit IB. Specify a value in the basic machine coordinates system.

±99999.999 (mm)

2063 OT_1B type

Soft limit IB type

Select OT_IB or OT_IC in which OT_IB+/− is used in stored stroke limit I.

0. Soft limit IB valid 1: Soft limit IB and IC invalid 2: Soft limit IC valid

2068 G0fwdg G00 feed forward gain

Specify the feed forward gain applicable to acceleration/deceleration before G00 interpolation. The greater the set value, the shorter the positioning time during in-position checking. If machine vibration occurs, decrease the set value.

2069 Rcoeff Axis arc radius error correction efficient

The amount of arc radius error correction can be increased or decreased between -100% to +100% for each axis.

div_RT Rotational axis division count

Specify the number of divisions of one turn of the rotational axis for purpose of control.

(Example) When 36 is set, one turn is supposed to

be 36.000. (Note) When 0 is set, the normal rotational axis

(360.000 degrees for one turn) is assumed. * If this parameter is changed when the absolute position detection specification is used, absolute position data is lost. Initialization must be performed again.

0/1/2

Page 84 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 6.4 Axis Specifications Parameters 2
Page 84 · click to enlarge
Page 84
6. Axis Specifications Parameters 6.4 Axis Specifications Parameters 2

# Items Details Setting range (unit)

2073 zrn_dog Origin dog Random assignment device

When it is desired to assign the origin dog signal to a position other than the fixed device, specify the input device in this parameter. (Note1) This parameter is valid when 1 is set in #1226

000 to 3FF (HEX)

aux10 bit 5. (Note2) When this parameter is valid, do not set the

same device number. If the same device number exists, an emergency stop occurs. Note that the device number is not checked for an axis to which a signal that ignores the fixed signal is input. (Note3) The setting range of this parameter has been

expanded on the software Ver.D0 and later.

2074 H/W_OT+ H/W OT+ Random assignment device

When it is desired to assign the OT (+) g signal to a position other than the fixed device, specify the input device in this parameter. (Note1) This parameter is valid when 1 is set in #1226

000 to 3FF (HEX)

aux10 bit 5. (Note2) When this parameter is valid, do not set the

same device number. If the same device number exists, an emergency stop occurs. Note that the device number is not checked for an axis to which a signal that ignores the fixed signal is input. (Note3) The setting range of this parameter has been

expanded on the software Ver.D0 and later.

2075 H/W_OT- H/W OT- Random assignment device

When it is desired to assign the OT (-) g signal to a position other than the fixed device, specify the input device in this parameter. (Note1) This parameter is valid when 1 is set in #1226

000 to 3FF (HEX)

aux10 bit 5. (Note2) When this parameter is valid, do not set the

same device number. If the same device number exists, an emergency stop occurs. Note that the device number is not checked for an axis to which a signal that ignores the fixed signal is input. (Note3) The setting range of this parameter has been

expanded on the software Ver.D0 and later.

2076 index_x Index table indexing axis

Specify the index table indexing axis.

0. Normal axis 1: Index table indexing axis (Note) This parameter is valid only for the NC axis. The

parameter is invalid if specified for the PLC axis.

0/1

Page 85 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 6.4 Axis Specifications Parameters 2
Page 85 · click to enlarge
Page 85
6. Axis Specifications Parameters 6.4 Axis Specifications Parameters 2

# Items Details Setting range (unit)

22011 bscmp− Offset compensa- tion position

Specify the coordinates on the machine basic coordinates where the compensation is carried out by the offset amount.

±99999.999

22012 bscmp+ Max. compensa- tion position

Specify the coordinates on the machine basic coordinates where the compensation is carried out by the max. offset amount.

±99999.999

(Note) The positional relation of either #22011 and #22012 can be on the minus side.

Page 86 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7. Servo Parameters
Page 86 · click to enlarge
Page 86
7. Servo Parameters

7. Servo Parameters

The parameters can be changed from any screen. The valid servo parameters will differ according to the motor type. The setting values and meanings may also differ. Follow the correspondence table given below, and set the correct parameters. Refer to each Instruction Manual or the following manuals for details on each motor.

MELDAS AC Servo/ Spindle MDS-A Series MDS-B Series Specification Manual BNP-B3759 MELDAS AC Servo MDS-B-SVJ2 Series Specification and Instruction Manual BNP-B3937 MELDAS AC Servo/ Spindle MDS-C1 Series Specification Manual BNP-C3000

(Standard) (MDS-B-Vx) SV001 Motor side gear ratio SV002 Machine side gear ratio SV003 Position loop gain 1 SV004 Position loop gain 2 SV005 Speed loop gain 1 SV006 Speed loop gain 2 – SV007 Speed loop delay compensation – SV008 Speed loop lead compensation SV009 Current loop q axis lead compensation SV010 Current loop d axis lead compensation SV011 Current loop q axis gain SV012 Current loop d axis gain SV013 Current limit value SV014 Current limit value in special control SV015 Acceleration rate feed forward gain SV016 Lost motion compensation 1 SV017 Servo specification selection SV018 Ball screw pitch SV019 Position detector resolution SV020 Speed detector resolution SV021 Overload detection time constant SV022 Overload detection level

SV023 Excessive error detection width during servo ON

SV024 In-position detection width SV025 Motor/Detector type

SV026 Excessive error detection width during servo OFF

SV027 Servo function selection 1 SV028 Linear motor magnetic pole shift length – – – SV029 Speed at the change of speed loop gain – SV030 Voltage dead time compensation –/ / / SV031 Overshooting compensation 1 SV032 Torque offset

Show 5 more labels / short text on this page
Corresponding model · MDS-C1-Vx · MDS-C1-Vx · Parameter MDS-B-SVJ2 · (High-gain) (MDS-B-Vx4)
Page 87 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7. Servo Parameters
Page 87 · click to enlarge
Page 87
7. Servo Parameters

(Standard) (MDS-B-Vx) SV033 Servo function selection 2 SV034 Servo function selection 3 SV035 Servo function selection 4 SV036 Regenerative resistor type SV037 Load inertia scale SV038 Notch filter frequency 1 – SV039 Lost motion compensation timing – SV040 Non-sensitive band in feed forward control –/ / / SV041 Lost motion compensation 2 SV042 Overshooting compensation 2 SV043 Disturbance observer filter frequency SV044 Disturbance observer gain SV045 Frictional torque –/ / / SV046 Notch filter frequency 2 – – SV047 Inductive voltage compensation gain SV048 Vertical axis drop prevention time

SV049 Position loop gain 1 in spindle synchronous control

SV050 Position loop gain 2 in spindle synchronous control

SV051 Dual feedback control time constant – SV052 Dual feedback control non-sensitive band –

SV053 Excessive error detection width in special control

SV054 Overrun detection width in closed loop control –/–

SV055 Max. gate off delay time after emergency stop –

SV056 Deceleration time constant at emergency stop

SV057 SHG control gain

SV058 SHG control gain in spindle synchronous control

SV059 Collision detection torque estimating gain SV060 Collision detection level

SV061 D/A output channel 1 data No. SV062 D/A output channel 2 data No.

SV063 D/A output channel 1 output scale SV064 D/A output channel 2 output scale SV065 Tool end compensation spring constant – –

Show 6 more labels / short text on this page
Corresponding model · MDS-C1-Vx · MDS-C1-Vx · Parameter MDS-B-SVJ2 · (High-gain) (MDS-B-Vx4) · / /
Page 88 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2212 SV012 IDG
Page 88 · click to enlarge
Page 88
7. Servo Parameters 7.1 MDS-B-SVJ2

7.1 MDS-B-SVJ2

(1) Details for servo parameters

For parameters marked with a (PR) in the table, turn the NC power OFF after setting. After the power is turned ON again, the parameter is validated.

! CAUTION

! In the explanation on bits, set all bits not used, including blank bits, to “0”.

No. Items Details Setting range

SV001 PC1

Motor side gear ratio

Set the motor side and machine side gear ratio. For the rotary axis, set the total deceleration (acceleration) ratio. Even if the gear ratio is within the setting range, the electronic gears may overflow and cause an alarm.

SV002 PC2

Machine side gear ratio

2203 SV003 PGN1

Position loop gain 1

Set the position loop gain. The standard setting is “33”. The higher the setting value is, the more precisely the command can be followed and the shorter the positioning time gets, however, note that a bigger shock is applied to the machine during acceleration/deceleration. When using the SHG control, also set SV004 (PGN2) and SV057 (SHGC).

1 to 200 (rad/s)

2204 SV004 PGN2

Position loop gain 2

When using the SHG control, also set SV003 (PGN1) and SV057 (SHGC). When not using the SHG control, set to “0”.

0 to 999 (rad/s)

2205 SV005 VGN1

Set the speed loop gain. Set this according to the load inertia size. The higher the setting value is, the more accurate the control will be, however, vibration tends to occur. If vibration occurs, adjust by lowering by 20 to 30%. The value should be determined to be 70 to 80% of the value at the time when the vibration stops.

2206 Not used. Set to “0”. 0

2207 Not used. Set to “0”. 0

2208 SV008 VIA

Speed loop lead compensation

Set the gain of the speed loop integration control. The standard setting is “1364”. During the SHG control, the standard setting is “1900”. Adjust the value by increasing/decreasing it by about 100 at a time. Raise this value to improve contour tracking precision in high-speed cutting. Lower this value when the position droop vibrates (10 to 20Hz).

2209 SV009 IQA

Current loop q axis lead compensation

Set the gain of current loop. As this setting is determined by the motor’s electrical characteristics, the setting is fixed for each type of motor. Set the standard values for all the parameters depending on each motor type.

2210 SV010 IDA

Current loop d axis lead compensation

2211 SV011 IQG

Current loop q axis gain

2212 SV012 IDG

Current loop d axis gain

Speed loop gain

Page 89 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2216 SV016 LMC1
Page 89 · click to enlarge
Page 89
7. Servo Parameters 7.1 MDS-B-SVJ2

No. Items Details Setting range

2213 SV013 ILMT

Set the normal current (torque) limit value. (Limit values for both + and - direction.) When the value is “500” (a standard setting), the maximum torque is determined by the specification of the motor.

0 to 500 (Stall [rated] current %)

Current limit value in special control

Set the current (torque) limit value in a special control (initial absolute position setting, stopper control, etc). (Limit values for both of the + and - directions.) Set to “500” when not using.

0 to 500 (Stall [rated] current %)

2215 SV015 FFC

Acceleration rate feed forward gain

When a relative error in the synchronous control is large, apply this parameter to the axis that is delaying. The standard setting value is “0”. For the SHG control, set to “100”. To adjust a relative error in acceleration/ deceleration, increase the value by 50 to 100 at a time.

2216 SV016 LMC1

Lost motion compensation 1

Set this when the protrusion (that occurs due to the non-sensitive band by friction, torsion, backlash, etc) at quadrant change is too large. This compensates the torque at quadrant change. This is valid only when the lost motion compensation (SV027 (SSF1/lmc)) is selected.

Type 1: When SV027 (SSF1)/ bit9, 8 (lmc)=01 Set the compensation amount based on the motor torque before the quadrant change. The standard setting is “100”. Setting to “0” means the compensation amount is zero. Normally, use Type 2.

Type 2: When SV027 (SSF1)/ bit9, 8 (lmc)=10 Set the compensation amount based on the stall (rated) current of the motor. The standard setting is double of the friction torque. Setting to “0” means the compensation amount is zero.

-1 to 100 (Stall [rated] current %)

When you wish different compensation amount depending on the direction When SV041 (LMC2) is “0”, compensate with the value of SV016 (LMC1) in both of the + and -directions. If you wish to change the compensation amount depending on the command direction, set this and SV041 (LMC2). (SV016: + direction, SV041: - direction. However, the directions may be opposite depending on other settings.) When “-1” is set, the compensation won’t be performed in the direction of the command.

Current limit value · 2214 SV014 ILMTsp

Page 90 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.1 MDS-B-SVJ2
Page 90 · click to enlarge
Page 90
7. Servo Parameters 7.1 MDS-B-SVJ2
Mitsubishi Electronics CNC Controller Board (C64) — 7.1 MDS-B-SVJ2 diagram (page 90)
Fig. 27

7 6 5 4 3 2 1 0 abs vdir mc dmk

bit Meaning when “0” is set Meaning when “1” is set

3 mc Contactor control output invalid Contactor control output valid

HA053N to HA33N motor Detector installation position standard (A, C)

HA053N to HA33N motor Detector installation position 90 degrees (B, D)

(Note) Set to “0” for bits with no particular description.

Set the ball screw pitch. Set to “360” for the rotary axis. 1 to 32767 (mm/rev)

For both parameters, set the number of pulses per one revolution of the motor detector.

Page 91 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2224 SV024 INP
Page 91 · click to enlarge
Page 91
7. Servo Parameters 7.1 MDS-B-SVJ2

No. Items Details Setting range

2221 SV021 OLT

Overload detection time constant

Set the detection time constant of Overload 1 (Alarm 50). Set to “60” as a standard. (For machine tool builder adjustment.)

1 to 300 (s)

2222 SV022 OLL

Set the current detection level of Overload 1 (Alarm 50) in respect to the stall (rated) current. Set to “150” as a standard. (For machine tool builder adjustment.)

2223 SV023 OD1

Excessive error detection width during servo ON

Set the excessive error detection width when servo ON.

0 to 32767 (mm)

OD1=OD2= 60*PGN1

When “0” is set, the excessive error detection will not be performed.

2224 SV024 INP

Set the in-position detection width. Set the accuracy required for the machine. The lower the setting is, the higher the positioning accuracy gets, however, the cycle time (setting time) becomes longer. The standard setting is “50”.

0 to 32767 (µm)

Show 8 more labels / short text on this page
Overload detection level · (Stall [rated] · current %) · <Standard setting value> · Rapid traverse rate · (mm/min) · /2 (mm) · In-position detection width
Page 92 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.1 MDS-B-SVJ2
Page 92 · click to enlarge
Page 92
7. Servo Parameters 7.1 MDS-B-SVJ2
Mitsubishi Electronics CNC Controller Board (C64) — 7.1 MDS-B-SVJ2 diagram (page 92)
Fig. 28

F E D C B A 9 8 pen ent

7 6 5 4 3 2 1 0 mtyp

1 Set- ting 0x 1x 2x 3x 4x 5x 6x 7x 8x

Page 93 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — B
Page 93 · click to enlarge
Page 93
7. Servo Parameters 7.1 MDS-B-SVJ2

No. Items Details Setting range (Continued from the previous page)

bit Explanation 8 9

Set the speed detector type. Set to “2”.

A

B

C D

Set the position detector type. Set to “2”.

E

F

2226 SV026 OD2

Excessive error detection width during servo OFF

Set the excessive error detection width when servo ON. For the standard setting, refer to the explanation of SV023 (OD1). When “0” is set, the excessive error detection will not be performed.

0 to 32767 (mm)

2227 SV027 SSF1

Servo function selection 1

F E D C B A 9 8 aflt zrn2 ovs lmc

7 6 5 4 3 2 1 0 vfct zup

bit Meaning when “0” is set Meaning when “1” is set

0 zup Vertical axis lift-up control stop Vertical axis lift-up control start 1

4 Set the jitter compensation No. of compensation pulses with a binary. 5 vfct

0. Jitter compensation invalid 01: Jitter compensation 1 pulse 10: Jitter compensation 2 pulses 11: Jitter compensation 3 pulses

8 Set the compensation amount with SV016 (LMC1) and SV041 (LMC2). 9 lmc

0. Lost motion compensation stop 01: Lost motion compensation type 1 10: Lost motion compensation type 2 11: Setting prohibited

A Set the compensation amount with SV031 (OVS1) and SV042 (OVS2).

B

0. Overshooting compensation stop 01: Overshooting compensation type 1 10: Overshooting compensation type 2 11: Setting prohibited C D

E zrn2 Set to “1”.

F aflt Adoptive filter stops Adoptive filter starts

(Note) Set to “0” for bits with no particular description.

ent · pen · ovs

Page 94 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2232 SV032 TOF
Page 94 · click to enlarge
Page 94
7. Servo Parameters 7.1 MDS-B-SVJ2

No. Items Details Setting range

2228 SV028 Not used. Set to “0”. 0

2229 SV029 Not used. Set to “0”. 0

2230 SV030 IVC

Voltage dead time compensa- tion

When 100% is set, the voltage equivalent to the logical non-energized time will be compensated. Adjust in increments of 10% from the default value 100%. If increased too much, vibration or vibration noise may be generated. When not using, set to “0”.

2231 SV031 OVS1

Set this if overshooting occurs during positioning. This compensates the motor torque during positioning. This is valid only when the overshooting compensation SV027 (SSF1/ovs) is selected.

-1 to 100 (Stall [rated] current %)

Type 1: When SV027 (SSF1)/ bit11, 10 (ovs)=01 Set the compensation amount based on the motor’s stall (rated) current. Increase by 1% and determine the amount that overshooting doesn’t occur. In Type 1, compensation during the feed forward control during circular cutting won’t be performed.

Type 2: When SV027 (SSF1)/ bit11, 10 (ovs)=10 Use this if you perform the overshooting compensation during the feed forward control during circular cutting. The setting method is the same in Type 1.

When you wish different compensation amount depending on the direction When SV042 (OVS2) is “0”, compensate with the value of SV031 (OVS1) in both of the + and -directions. If you wish to change the compensation amount depending on the command direction, set this and SV042 (OVS2). (SV031: + direction, SV042: - direction. However, the directions may be opposite depending on other settings.) When “-1” is set, the compensation won’t be performed in the direction of the command.

2232 SV032 TOF

Set the unbalance torque of vertical axis and inclined axis.

-100 to 100 (Stall [rated] current %)

Overshoot- ing compensa- tion 1 · Torque offset

Page 95 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.1 MDS-B-SVJ2
Page 95 · click to enlarge
Page 95
7. Servo Parameters 7.1 MDS-B-SVJ2
Mitsubishi Electronics CNC Controller Board (C64) — 7.1 MDS-B-SVJ2 diagram (page 95)
Fig. 29

F E D C B A 9 8 afs

7 6 5 4 3 2 1 0 fhz2 nfd

bit Meaning when “0” is set Meaning when “1” is set 0 Set the filter depth for Notch filter (SV038: FHz1). 1 The control is stabilized by making the filter shallower.

2 Value 0 2 4 6 8 A C E

DeepÅ Æ Shallow 4 Set the operation frequency of Notch filter 2. 5 fhz2 00: No operation 01:2250Hz 10:1125Hz 11:750Hz

Set the vibration sensitivity of the adaptive filter. If the filter depth is not deep enough (generally 70% or more) and the vibration cannot be sufficiently eliminated, raise the value.

(Note) Set to “0” for bits with no particular description.

Page 96 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — A
Page 96 · click to enlarge
Page 96
7. Servo Parameters 7.1 MDS-B-SVJ2

No. Items Details Setting range

F E D C B A 9 8

2234 SV034 SSF3

Servo function selection 3

7 6 5 4 3 2 1 0 daf2 daf1 dac2 dac1 mon

bit Meaning when “0” is set Meaning when “1” is set 0 NC servo monitor MAX current display data changeover

1 Set- ting MAX current 1 MAX current 2

2 0 Max. current command value when power is turned ON (%)

Max. current command value for one second (%)

1 Max. current command value for one second (%)

Max. current FB value for one second (%)

2 Max. current FB value when power is turned ON (%)

Max. current FB value for one second (%)

3 Load inertia rate (%) -

4 Adaptive filter operation frequency (Hz)

Adaptive filter operation gain (%)

5 PN bus voltage (V) Regenerative operation frequency monitor (The number of times/sec)

6 Estimated max. torque for one second (%)

Max. current FB value for one second (%)

7 Estimated max. torque for one second (%)

Max. disturbance torque for two seconds (%)

8 to F Setting prohibited

4 dac1 D/A output ch.1 overflow setting D/A output ch.1 clamp setting 5 dac2 D/A output ch.2 overflow setting D/A output ch.2 clamp setting

6 daf1 D/A output ch.1 no filter D/A output ch.1 filter setting

7 daf2 D/A output ch.2 no filter D/A output ch.2 filter setting

A

B

C D

E

F

(Note) Set to “0” for bits with no particular description.

mon

Page 97 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.1 MDS-B-SVJ2
Page 97 · click to enlarge
Page 97
7. Servo Parameters 7.1 MDS-B-SVJ2
Mitsubishi Electronics CNC Controller Board (C64) — 7.1 MDS-B-SVJ2 diagram (page 97)
Fig. 30

F E D C B A 9 8 cl2n clG1

bit Meaning when “0” is set Meaning when “1” is set 0 1

Collision detection method 1 Set the collision detection level during cutting feed (G1). The G1 collision detection level=SV060*clG1. When clG1=0, the collision detection method 1 during cutting feed won’t function.

(Note) Set to “0” for bits with no particular description.

Page 98 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.1 MDS-B-SVJ2
Page 98 · click to enlarge
Page 98
7. Servo Parameters 7.1 MDS-B-SVJ2
Mitsubishi Electronics CNC Controller Board (C64) — 7.1 MDS-B-SVJ2 diagram (page 98)
Fig. 31

F E D C B A 9 8 amp rtyp

7 6 5 4 3 2 1 0 emgx

4 Set the external emergency stop function. (Setting is prohibited for values with no description.)

A 0 Drive unit standard built-in resistor (SVJ2-01 doesn’t have a built-in resistor)

4 MR-RB32 or GZG200W1200HMK3 units connected in parallel
5 MR-RB30 or GZG200W390HMK3 units connected in parallel
6 MR-RB50 or GZG300W390HMK3 units connected in parallel
Page 99 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2247 SV047 EC
Page 99 · click to enlarge
Page 99
7. Servo Parameters 7.1 MDS-B-SVJ2

No. Items Details Setting range

2237 SV037 JL Load inertia scale

Set “the motor inertia + motor axis conversion load inertia” in respect to the motor inertia.

SV037 (JL) =

JmMotor inertia
JlMotor axis conversion load inertia

Notch filter frequency 1

Set the vibration frequency to suppress if machine vibration occurs. (Valid at 72 or more) When not using, set to “0”.

0 to 3000 (Hz)

2239 SV039 LMCD

Lost motion compensation timing

Set this when the lost motion compensation timing doest not match. Adjust by increasing the value by 10 at a time.

0 to 2000 (ms)

2240 SV040 LMCT

Non-sensitive band in feed forward control

Set the non-sensitive bad of the lost motion compensation and overshooting compensation during the feed forward control. When “0” is set, the actual value that will be set is 2µm. Adjust by increasing by 1µm.

2241 SV041 LMC2

Lost motion compensation 2

Set this with SV016 (LMC1) only when you wish to set the lost motion compensation amount to be different depending on the command directions. Set to “0” as a standard.

-1 to 200 (Stall [rated] current %)

2242 SV042 OVS2

Set this with SV031 (OVS1) only when you wish to set the overshooting compensation amount to be different depending on the command directions. Set to “0” as a standard.

-1 to 100 (Stall [rated] current %)

2243 SV043 OBS1

Disturbance observer filter frequency

Set the disturbance observer filter band. The standard setting is “300”. Lower the setting by 50 at a time if vibration occurs. To use the disturbance observer, also set SV037 (JL) and SV044 (OBS2). When not using, set to “0”.

0 to 1000 (rad/s)

2244 SV044 OBS2

Set the disturbance observer gain. The standard setting is “100” to “300”. To use the disturbance observer, also set SV037 (JL) and SV043 (OBS1). When not using, set to “0”.

2245 SV045 TRUB

Set the frictional torque when using the collision detection function.

0 to 100 (Stall [rated] current %)

2246 SV046 Not used. Set to “0”. 0

2247 SV047 EC

Inductive voltage compensation gain

Set the inductive voltage compensation gain. Set to “100” as a standard. If the current FB peak exceeds the current command peak, lower the gain.

Vertical axis drop prevention time

Input a length of time to prevent the vertical axis from dropping by delaying Ready OFF until the brake works when the emergency stop occurs. Increase the setting by 100ms at a time and set the value where the axis does not drop.

Show 11 more labels / short text on this page
Jl+Jm · *100 · Jm · 2238 SV038 FHz1 · (µm) · Overshooting compensation 2 · Disturbance observer gain · Frictional torque · (%) · 2248 SV048 EMGrt · (ms)
Page 100 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2260 SV060 TLMT
Page 100 · click to enlarge
Page 100
7. Servo Parameters 7.1 MDS-B-SVJ2

No. Items Details Setting range

Position loop gain 1 in spindle synchronous control

Set the position loop gain during the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis). Set the same value as the value of the spindle parameter, position loop gain in synchronous control. When performing the SHG control, set this with SV050 (PGN2sp) and SV058 (SHGCsp).

1 to 200 (rad/s)

2250 PGN2sp Position loop gain 2 in spindle synchronous control

Set this with SV049 (PGN1sp) and SV058 (SHGCsp) if you wish to perform the SHG control in the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis). When not performing the SHG control, set to “0”.

0 to 999 (rad/s)

2251 SV051 Not used. Set to “0”. 0

2252 SV052 Not used. Set to “0”. 0

2253 SV053 OD3

Excessive error detection width in special control

Set the excessive error detection width when servo ON in a special control (initial absolute position setting, stopper control, etc.). If “0” is set, excessive error detection won’t be performed when servo ON during a special control.

0 to 32767 (mm)

2254 SV054 Not used. Set to “0”. 0

2255 SV055 Not used. Set to “0”. 0

Deceleration time constant at emergency stop

Set the time constant used for the deceleration control at emergency stop. Set a length of time that takes from rapid traverse rate (rapid) to stopping. Normally, set the same value as the rapid traverse acceleration/deceleration time constant.

0 to 5000 (ms)

2257 SV057 SHGC

When performing the SHG control, set this with S003 (PGN1) and SV004 (PGN2). When not performing the SHG control, set to “0”.

0 to 999 (rad/s)

SHG control gain in spindle synchronous control

Set this with SV049 (PGN1sp) and SV050 (PGN2sp) if you wish to perform the SHG control in the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis). When not performing the SHG control, set to “0”.

0 to 999 (rad/s)

2259 SV059 TCNV

Collision detection torque estimating gain

To use the collision detection function, set the torque estimating gain. In the case of MDS-B-SVJ2, the value is the same as the load inertia ratio that includes the motor inertia. (=SV037:JL) If acceleration/deceleration is performed after setting SV034.mon=3 and SV060=0, the load inertia ratio will be displayed on the NC monitor screen.

2260 SV060 TLMT

When using the collision detection function, set the collision detection level during the G0 feeding. If “0” is set, none of the collision detection function will work.

0 to 200 (Stall [rated] current %)

Show 5 more labels / short text on this page
2249 SV049 PGN1sp · 2256 SV056 EMGt · SHG control gain · 2258 SV058 SHGCsp · Collision detection level
Page 101 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2264 SV064 DA2MPY
Page 101 · click to enlarge
Page 101
7. Servo Parameters 7.1 MDS-B-SVJ2

No. Items Details Setting range

2261 SV061 DA1NO

D/A output channel 1 data No.

Input the data number you wish to output to D/A output channel.

2262 SV062 DA2NO

D/A output channel 2 data No.

2263 SV063 DA1MPY

D/A output channel 1 output scale

When “0” is set, output is done with the standard output unit. Set other than “0” when you wish to change the unit. Set the scale with a 1/256 unit. When “256” is set, the output unit will be the same as the standard output unit.

(Unit1/256)

2264 SV064 DA2MPY

D/A output channel 2 output scale

2265 SV065 Not used. Set to “0”. 0

Page 102 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.1 MDS-B-SVJ2
Page 102 · click to enlarge
Page 102
7. Servo Parameters 7.1 MDS-B-SVJ2

(2) Initial setting value

52 HC 102* HC 102 HC 152* HC 152 HC 202* HC 202 HC 352* Drive unit

capacity 06 07 10 10 20 10 20 20

SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 50 80 50 80 50 115 80 130 SV006 0 SV007 0 SV008 VIA 1364 SV009 IQA 8192 4096 8192 4096 8192 2048 4096 2048 SV010 IDA 8192 4096 8192 4096 8192 2048 4096 2048 SV011 IQG 512 256 384 256 384 256 384 256 SV012 IDG 512 256 384 256 384 256 384 256 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 - SV024 INP 50 SV025 MTYP 22B0 22B1 22B1 22B2 22B2 22B3 22B3 22B4 SV026 OD2 - SV027 SSF1 4000 SV028 0 SV029 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0

(a) HC**/HC**R series · Motor HC

Page 103 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.1 MDS-B-SVJ2
Page 103 · click to enlarge
Page 103
7. Servo Parameters 7.1 MDS-B-SVJ2

52 HC 102* HC 102 HC 152* HC 152 HC 202* HC 202 HC 352* Drive unit

capacity 06 07 10 10 20 10 20 20

SV033 SSF2 0 SV034 SSF3 0 SV035 SSF4 0 SV036 PTYP - SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 0 SV052 0 SV053 OD3 0 SV054 0 SV055 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0

Motor HC

Page 104 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.1 MDS-B-SVJ2
Page 104 · click to enlarge
Page 104
7. Servo Parameters 7.1 MDS-B-SVJ2

53 HC 103 HC 153 HC 203* HC 103R HC 153R HC 203R Drive unit

capacity 06 10 20 20 10 10 20

SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 80 80 80 100 10 10 10 SV006 0 SV007 0 SV008 VIA 1364 SV009 IQA 4096 4096 4096 2048 8192 8192 8192 SV010 IDA 4096 4096 4096 2048 8192 8192 8192 SV011 IQG 256 256 256 200 384 384 256 SV012 IDG 256 256 256 200 384 384 256 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 - SV024 INP 50 SV025 MTYP 22C0 22C1 22C2 22C3 22E1 22E2 22E3 SV026 OD2 - SV027 SSF1 4000 SV028 0 SV029 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0

Motor HC

Page 105 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.1 MDS-B-SVJ2
Page 105 · click to enlarge
Page 105
7. Servo Parameters 7.1 MDS-B-SVJ2

53 HC 103 HC 153 HC 203* HC 103R HC 153R HC 203R Drive unit

capacity 06 10 20 20 10 10 20

SV033 SSF2 0 SV034 SSF3 0 SV035 SSF4 0 SV036 PTYP - SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 0 SV052 0 SV053 OD3 0 SV054 0 SV055 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0

Motor HC

Page 106 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.1 MDS-B-SVJ2
Page 106 · click to enlarge
Page 106
7. Servo Parameters 7.1 MDS-B-SVJ2

Motor HA 40N HA 80N HA 100N HA 200N* HA 053N HA 13N HA 23N HA 33N HA 43N HA 83N HA 103N* Drive unit

capacity 06 10 20 20 01 01 03 03 06 10 20

SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 90 150 150 220 35 120 150 180 SV006 0 SV007 0 SV008 VIA 1364 SV009 IQA 2048 SV010 IDA 2048 SV011 IQG 512 512 512 200 256 512 512 512 SV012 IDG 512 512 512 200 256 512 512 512 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 - SV024 INP 50 SV025 MTYP 2200 2201 2202 2203 228C 228D 228E 228F 2280 2281 2282 SV026 OD2 - SV027 SSF1 4000 SV028 0 SV029 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0

(b) HA**N series

Page 107 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.1 MDS-B-SVJ2
Page 107 · click to enlarge
Page 107
7. Servo Parameters 7.1 MDS-B-SVJ2

Motor HA 40N HA 80N HA 100N HA 200N* HA 053N HA 13N HA 23N HA 33N HA 43N HA 83N HA 103N* Drive unit

capacity 06 10 20 20 01 01 03 03 06 10 20

SV033 SSF2 0 SV034 SSF3 0 SV035 SSF4 0 SV036 PTYP - SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 0 SV052 0 SV053 OD3 0 SV054 0 SV055 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0

Page 108 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 52 HC-SF
Page 108 · click to enlarge
Page 108
7. Servo Parameters 7.1 MDS-B-SVJ2

52 HC-SF

102 HC-SF

152 HC-SF

202 HC-SF

352 HC-SF

53 HC-SF

103 HC-SF

153 HC-SF

203 HC-SF

capacity 06 07 10 10 20 06 07 10 10 20

SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 80 80 80 120 130 90 90 130 180 180 SV006 0 SV007 0 SV008 VIA 1364 SV009 IQA 8192 4096 4096 2048 2048 4096 4096 2048 2048 2048 SV010 IDA 8192 4096 4096 2048 2048 4096 4096 2048 2048 2048 SV011 IQG 500 300 300 300 250 250 250 200 200 200 SV012 IDG 500 300 300 300 250 250 250 200 200 200 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 16 SV020 RNG2 16 SV021 OLT 60 SV022 OLL 150 SV023 OD1 - SV024 INP 50 SV025 MTYP 22B0 22B1 22B2 22B3 22B4 22C0 22C1 22C2 22C3 22C4 SV026 OD2 - SV027 SSF1 4000 SV028 0 SV029 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0

(c) HC-SF series · Motor HC-SF · 353 Drive unit

Page 109 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 52 HC-SF
Page 109 · click to enlarge
Page 109
7. Servo Parameters 7.1 MDS-B-SVJ2

52 HC-SF

102 HC-SF

152 HC-SF

202 HC-SF

352 HC-SF

53 HC-SF

103 HC-SF

153 HC-SF

203 HC-SF

capacity 06 07 10 10 20 06 07 10 10 20

SV033 SSF2 0 SV034 SSF3 0 SV035 SSF4 0 SV036 PTYP - SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 0 SV052 0 SV053 OD3 0 SV054 0 SV055 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0

Motor HC-SF · 353 Drive unit

Page 110 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 103 HC-RF
Page 110 · click to enlarge
Page 110
7. Servo Parameters 7.1 MDS-B-SVJ2

103 HC-RF

153 HC-RF

203 HA-FF

053 HA-FF

13 HA-FF

23 HA-FF

33 HA-FF

43 HA-FF

capacity 10 10 20 01 01 03 03 04 06

SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 10 13 13 18 20 20 SV006 0 SV007 0 SV008 VIA 1364 SV009 IQA 8192 4096 SV010 IDA 8192 4096 SV011 IQG 384 384 256 500 300 700 500 700 700 SV012 IDG 384 384 256 500 300 700 500 700 700 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 16 16 16 8 SV020 RNG2 16 16 16 8 SV021 OLT 60 SV022 OLL 150 SV023 OD1 - SV024 INP 50 SV025 MTYP 22E1 22E2 22E3 227C 227D 227E 227F 2270 2271 SV026 OD2 - SV027 SSF1 4000 SV028 0 SV029 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0

(d) HC-RF/HA-FF series · Motor HC-RF · 63 Drive unit

Page 111 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 103 HC-RF
Page 111 · click to enlarge
Page 111
7. Servo Parameters 7.1 MDS-B-SVJ2

103 HC-RF

153 HC-RF

203 HA-FF

053 HA-FF

13 HA-FF

23 HA-FF

33 HA-FF

43 HA-FF

capacity 10 10 20 01 01 03 03 04 06

SV033 SSF2 0 SV034 SSF3 0 SV035 SSF4 0 SV036 PTYP - SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 0 SV052 0 SV053 OD3 0 SV054 0 SV055 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0

Motor HC-RF · 63 Drive unit

Page 112 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 053 HC-MF
Page 112 · click to enlarge
Page 112
7. Servo Parameters 7.1 MDS-B-SVJ2

053 HC-MF

13 HC-MF

23 HC-MF

43 HC-MF

capacity 01 01 03 04 07

SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 6 8 SV006 0 SV007 0 SV008 VIA 1364 SV009 IQA 4096 SV010 IDA 4096 SV011 IQG 200 300 400 300 300 SV012 IDG 200 300 400 300 300 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 8 SV020 RNG2 8 SV021 OLT 60 SV022 OLL 150 SV023 OD1 - SV024 INP 50 SV025 MTYP 229C 229D 229E 2290 2291 SV026 OD2 - SV027 SSF1 4000 SV028 0 SV029 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0

(e) HC-MF series · Motor HC-MF · 73 Drive unit

Page 113 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 053 HC-MF
Page 113 · click to enlarge
Page 113
7. Servo Parameters 7.1 MDS-B-SVJ2

053 HC-MF

13 HC-MF

23 HC-MF

43 HC-MF

capacity 01 01 03 04 07

SV033 SSF2 0 SV034 SSF3 0 SV035 SSF4 0 SV036 PTYP - SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 0 SV052 0 SV053 OD3 0 SV054 0 SV055 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0

Motor HC-MF · 73 Drive unit

Page 114 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — VGN1 VGN2
Page 114 · click to enlarge
Page 114
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

(1) Details for servo parameters

For parameters marked with a (PR) in the table, turn the NC power OFF after setting. After the power is turned ON again, the parameter is validated.

! CAUTION

! In the explanation on bits, set all bits not used, including blank bits, to “0”.

No. Items Details Setting range

SV001 PC1

Motor side gear ratio

Set the motor side and machine side gear ratio. For the rotary axis, set the total deceleration (acceleration) ratio. Even if the gear ratio is within the setting range, the electronic gears may overflow and cause an alarm.

SV002 PC2

Machine side gear ratio

2203 SV003 PGN1

Position loop gain 1

Set the position loop gain. The standard setting is “33”. The higher the setting value is, the more precisely the command can be followed and the shorter the positioning time gets, however, note that a bigger shock is applied to the machine during acceleration/deceleration. When using the SHG control, also set SV004 (PGN2) and SV057 (SHGC). (If “201” or bigger is set, the SHG control cannot be used.)

1 to 200 (In case of MDS-B-Vx4, 1 to 400) (rad/s)

2204 SV004 PGN2

Position loop gain 2

When using the SHG control, also set SV003 (PGN1) and SV057 (SHGC). When not using the SHG control, set to “0”.

2205 SV005 VGN1

Speed loop gain 1

Set the speed loop gain. Set this according to the load inertia size. The higher the setting value is, the more accurate the control will be, however, vibration tends to occur. If vibration occurs, adjust by lowering by 20 to 30%. The value should be determined to be 70 to 80% of the value at the time when the vibration stops.

2206 SV006 VGN2

Speed loop gain 2

If the noise is bothersome at high speed during rapid traverse, etc, lower the speed loop gain. As in the right figure, set the speed loop gain of the speed 1.2 times as fast as the motor’s rated speed, and use this with SV029 (VCS). When not using, set to “0”.

VGN1 VGN2

VCS VLMT 0

(Rated speed*1.2)

(rad/s)

Page 115 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2213 SV013 ILMT
Page 115 · click to enlarge
Page 115
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

No. Items Details Setting range

2207 SV007 VIL

Speed loop delay compensation

Set this when the limit cycle occurs in the full-closed loop, or overshooting occurs in positioning. Select the control method with SV027 (SSF1)/bit1, 0 (vcnt). Normally, use “Changeover type 2”. When you set this parameter, make sure to set the torque offset (SV032 (TOF)). When not using, set to “0”.

No changeover When SV027 (SSF1)/ bit1, 0 (vcnt)=00 The delay compensation control is always valid.

Changeover type 1 When SV027 (SSF1)/ bit1, 0 (vcnt)=01 The delay compensation control works when the command from the NC is “0”. Overshooting that occurs during pulse feeding can be suppressed.

Changeover type 2 When SV027 (SSF1)/ bit1, 0 (vcnt)=10 The delay compensation control works when the command from the NC is “0” and the position droop is “0”. Overshooting or the limit cycle that occurs during pulse feeding or positioning can be suppressed.

2208 SV008 VIA

Speed loop lead compensation

Set the gain of the speed loop integration control. The standard setting is “1364”. During the SHG control, the standard setting is “1900”. Adjust the value by increasing/decreasing it by about 100 at a time. Raise this value to improve contour tracking precision in high-speed cutting. Lower this value when the position droop vibrates (10 to 20Hz).

2209 SV009 IQA

Current loop q axis lead compensation

Set the gain of current loop. As this setting is determined by the motor’s electrical characteristics, the setting is fixed for each type of motor. Set the standard values for all the parameters depending on each motor type.

2210 SV010 IDA

Current loop d axis lead compensation

2211 SV011 IQG

Current loop q axis gain

1 to 4096 (In case of MDS-B-Vx4, 1 to 8192)

2212 SV012 IDG

Current loop d axis gain

2213 SV013 ILMT

Set the normal current (torque) limit value. (Limit values for both + and - direction.) When the value is “500” (a standard setting), the maximum torque is determined by the specification of the motor.

0 to 999 (Stall [rated] current %)

Current limit value in special control

Set the current (torque) limit value in a special control (initial absolute position setting, stopper control, etc). (Limit values for both of the + and - directions.) Set to “500” when not using.

0 to 999 (Stall [rated] current %)

Current limit value · 2214 SV014 ILMTsp

Page 116 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2216 SV016 LMC1
Page 116 · click to enlarge
Page 116
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

No. Items Details Setting range

2215 SV015 FFC

Acceleration rate feed forward gain

When a relative error in the synchronous control is large, apply this parameter to the axis that is delaying. The standard setting value is “0”. For the SHG control, set to “100”. To adjust a relative error in acceleration/deceleration, increase the value by 50 to 100 at a time.

2216 SV016 LMC1

Lost motion compensa- tion 1

Set this when the protrusion (that occurs due to the non-sensitive band by friction, torsion, backlash, etc) at quadrant change is too large. This compensates the torque at quadrant change. This is valid only when the lost motion compensation (SV027 (SSF1/lmc)) is selected.

Type 1: When SV027 (SSF1)/ bit9, 8 (lmc)=01 Set the compensation amount based on the motor torque before the quadrant change. The standard setting is “100”. Setting to “0” means the compensation amount is zero. Normally, use Type 2.

Type 2: When SV027 (SSF1)/ bit9, 8 (lmc)=10 Set the compensation amount based on the stall (rated) current of the motor. The standard setting is double of the friction torque. Setting to “0” means the compensation amount is zero.

-1 to 100 (Stall [rated] current %)

When you wish different compensation amount depending on the direction When SV041 (LMC2) is “0”, compensate with the value of SV016 (LMC1) in both of the + and -directions. If you wish to change the compensation amount depending on the command direction, set this and SV041 (LMC2). (SV016: + direction, SV041: - direction. However, the directions may be opposite depending on other settings.) When “-1” is set, the compensation won’t be performed in the direction of the command.

Page 117 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — F
Page 117 · click to enlarge
Page 117
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

No. Items Details Setting range

F E D C B A 9 8 spm drvall drvup mpt3 mp 7 6 5 4 3 2 1 0 abs vdir fdir vfb seqh dfbx fdir2

SV017 SPEC

bit Meaning when “0” is set Meaning when “1” is set

0 fdir2 Speed feedback forward polarity

Speed feedback reverse polarity 1 dfbx Dual feedback control stop Dual feedback control start

2 seqh READY/Servo ON time normal READY/Servo ON time high speed

3 vfb Speed feedback filter stop Speed feedback filter stop (2250Hz)

4 fdir Position feedback forward polarity

Position feedback reverse polarity 5 vdir Standard setting HA motor (4 pole motor)

Detector installation position 90 degrees (B, D)

7 abs Incremental control Absolute position control

8 mp MP scale 360P (2mm pitch) MP scale 720P (1mm pitch)

9 mpt3 MP scale ABS detection type 1, 2 MP scale ABS detection type 3

Standard setting Possible to connect a drive unit whose capacity is 1 rank higher/lower than the standard one.

Setting for normal use Possible to connect a drive unit with any capacity. C D

0 1 2 to F

: Setting for normal use : When using the S type drive unit (Only in the case of

E

MDS-C1-Vx)Setting prohibited

F

(Note 1) Set to “0” for bits with no particular description.

(Note 2) bit3 (vfb) is only for MDS-C1-Vx.

Show 4 more labels / short text on this page
Servo specification selection · A drvup · B drvall · spm
Page 118 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — OSE104, OSA104 100
Page 118 · click to enlarge
Page 118
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

No. Items Details Setting range

SV018 PIT

Set the ball screw pitch. Set to “360” for the rotary axis. 1 to 32767 (mm/rev)

SV019 RNG1

In the case of the semi-closed loop control Set the same value as SV020 (RNG2). (Refer to the explanation of SV020.)

1 to 9999 (kp/rev)

In the case of the semi-closed loop control Set the same value as SV020 (RNG2). (Refer to the explanation of SV020.)

1 to 9999 (kp/pit)

Detector model name Resolution SV019 setting OHE25K-ET, OHA25K-ET 100,000(p/rev) 100 OSE104-ET, OSA104-ET 100,000(p/rev) 100

OSE105-ET, OSA105-ET 1,000,000(p/rev) 1000

RCN723 (Heidenhain) 8,000,000(p/rev) 8000

Relative position detection scale

Refer to specification manual for each detector

AT41 (Mitsutoyo) 1 (µm/p) The same as SV018 (PIT)

FME type, FLE type (Futaba)

Refer to specification manual for each detector

MP type (Mitsubishi Heavy Industries)

Refer to specification manual for each detector

AT342 (Mitsutoyo) 0.5 (µm/p) Twice as big as SV018 (PIT)

AT343 (Mitsutoyo) 0.05 (µm/p) 20 times as big as SV018 (PIT)

LC191M (Heidenhain) Refer to specification manual for each detector

LC491M (Heidenhain) Refer to specification manual for each detector

SV020 RNG2

Set the number of pulses per one revolution of the motor end detector.

1 to 9999 (kp/rev)

Detector model name SV020 setting

OSE104, OSA104 100

OSE105, OSA105 1000

Show 8 more labels / short text on this page
Ball screw pitch · Position detector resolution · PIT/Resolution (µm) · PIT/Resolution (µm) · PIT/Resolution (µm) · PIT/Resolution (µm) · PIT/Resolution (µm) · Speed detector resolution
Page 119 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2224 SV024 INP
Page 119 · click to enlarge
Page 119
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

No. Items Details Setting range

2221 SV021 OLT

Overload detection time constant

Set the detection time constant of Overload 1 (Alarm 50). Set to “60” as a standard. (For machine tool builder adjustment.)

1 to 999 (s)

2222 SV022 OLL

Set the current detection level of Overload 1 (Alarm 50) in respect to the stall (rated) current. Set to “150” as a standard. (For machine tool builder adjustment.)

110 to 500 (Stall [rated] current %)

2223 SV023 OD1

Excessive error detection width during servo ON

Set the excessive error detection width when servo ON.

0 to 32767 (mm)

OD1=OD2= 60*PGN1

When “0” is set, the excessive error detection will not be performed.

2224 SV024 INP

Set the in-position detection width. Set the accuracy required for the machine. The lower the setting is, the higher the positioning accuracy gets, however, the cycle time (setting time) becomes longer. The standard setting is “50”.

0 to 32767 (µm)

Show 6 more labels / short text on this page
Overload detection level · <Standard setting value> · Rapid traverse rate · (mm/min) · /2 (mm) · In-position detection width
Page 120 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
Page 120 · click to enlarge
Page 120
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
Mitsubishi Electronics CNC Controller Board (C64) — 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) diagram (page 120)
Fig. 32 · 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

F E D C B A 9 8 pen ent 7 6 5 4 3 2 1 0 mtyp

bit Explanation 0 Set the motor type. 1 Set this along with SV017 (SPEC)/spm.

3 Set- ting 0x 1x 2x 3x 4x 5x 6x 7x

Set- ting 8x 9x Ax Bx Cx Dx Ex Fx

Page 121 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — B
Page 121 · click to enlarge
Page 121
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

No. Items Details Setting range (Continued from the previous page)

bit Explanation 2) When SV017/spm=1 (S type drive unit) Set- ting 8x 9x Ax Bx Cx Dx Ex Fx

8 Set the detector type. 9

Set the position detector type for “pen”, and the speed detector type for “ent”. In the case of the semi-closed loop control, set the same value for “pen” and “ent”.

A

pen setting ent setting Detector model name

B

C 0 0 OSE104 D 1 1 OSA104

E 2 2 OSE105, OSA105

F

OHE25K-ET, OSE104-ET

OHA25K-ET, OSA104-ET

OSE105-ET, OSA105-ET, RCN723 (Heidenhain)

Relative position detection scale, MP type (Mitsubishi Heavy Industries)

AT41 (Mitsutoyo), FME type, FLE type (Futaba)

AT342,AT343 (Mitsutoyo), LC191M/491M (Heidenhain), MDS-B-HR

C C (Current synchroni-

The setting of the slave axis in the speed/current synchronization control. When the master axis is the semi-closed control.

D E (Current synchroni-

The setting of the slave axis in the speed/current synchronization control. When the master axis is the full-closed control. (Current synchronization control is only for MDS-C2-Vx.)

Show 22 more labels / short text on this page
x4 HC353 · x5 HC452 HC453 · x6 HC702 · xA · xB · xD · xE · xF · ent · pen · 4 Setting impossible · 5 Setting impossible · 6 Setting impossible · 7 Setting impossible · 8 Setting impossible · 9 Setting impossible · A Setting impossible · B Setting impossible · zation) · zation) · E Setting impossible · F Setting impossible
Page 122 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — B
Page 122 · click to enlarge
Page 122
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

No. Items Details Setting range

2226 SV026 OD2

Excessive error detection width during servo OFF

Set the excessive error detection width when servo ON. For the standard setting, refer to the explanation of SV023 (OD1). When “0” is set, the excessive error detection will not be performed.

0 to 32767 (mm)

2227 SV027 SSF1

Servo function selection 1

F E D C B A 9 8 aflt zrn2 afse ovs lmc 7 6 5 4 3 2 1 0 omr zrn3 vfct upc vcnt

bit Meaning when “0” is set Meaning when “1” is set

0 Set the execution changeover type of the speed loop delay compensation. 1 vcnt

0. Delay compensation changeover invalid 01: Delay compensation changeover type 1 10: Delay compensation type 2 11: Setting prohibited

2 upc Start torque compensation invalid

Start torque compensation valid

4 Set the number of compensation pulses of the jitter compensation. 5 vfct

0. Jitter compensation invalid 01: Jitter compensation 1 pulse 10: Jitter compensation 2 pulses 11: Jitter compensation 3 pulses

6 zrn3 ABS scale: Set to “1” in using AT342, AT343, LC191M/491M.

7 omr Machine end compensation invalid

Machine end compensation valid

8 Set the compensation amount with SV016 (LMC1) and SV041 (LMC2). 9 lmc

0. Lost motion compensation stop 01: Lost motion compensation type 1 10: Overshooting compensation type 2 11: Setting prohibited

A Set the compensation amount with SV031 (OVS1) and SV042 (OVS2).

B

0. Overshooting compensation stop 01: Overshooting compensation type 1 10: Overshooting compensation type 2 11: Overshooting compensation type 3 C D afse 00: Adoptive filter sensitivity standard
11. Adoptive filter sensitivity increase (Set 2bits at a time)

E zrn2 Set to “1”.

F aflt Adoptive filter stop Adoptive filter start

(Note) Set to “0” for bits with no particular description.

2228 SV028 Not used. Set to “0”. 0

2229 SV029 Speed at the change of speed loop gain

If the noise is bothersome at high speed during rapid traverse, etc, lower the speed loop gain. Set the speed at which the speed loop gain changes, and use this with SV006 (VGN2). (Refer to SV006.) When not using, set to “0”.

0 to 9999 (r/min)

ovs

Page 123 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2232 SV032 TOF
Page 123 · click to enlarge
Page 123
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

No. Items Details Setting range

The higher order 8bits and lower order 8bits are used for different functions. “The setting value of SV030” = (Icx*256) + IVC

SV030 IVC (Low order)

Voltage dead time compensa- tion

When 100% is set, the voltage equivalent to the logical non-energized time will be compensated. When “0” is set, a 100% compensation will be performed. Adjust in increments of 10% from the default value 100%. If increased too much, vibration or vibration noise may be generated.

SV030 Icx (High order)

Current bias 1 Set to “0” as a standard. Use this in combination with SV040 and the high order 8bits of SV045.

2231 SV031 OVS1

Set this if overshooting occurs during positioning. This compensates the motor torque during positioning. This is valid only when the overshooting compensation SV027 (SSF1/ovs) is selected.

-1 to 100 (Stall [rated] current %)

Type 1: When SV027 (SSF1)/ bitB, A (ovs)=01 Set the compensation amount based on the motor’s stall current. This compensates overshooting that occurs during pulse feeding. Normally, use Type 2.

Type 2: When SV027 (SSF1)/ bitB, A (ovs)=10 Set the compensation amount based on the motor’s stall current. Increase by 1% and determine the amount that overshooting doesn’t occur. In Type 2, compensation during the feed forward control during circular cutting won’t be performed.

Type 3: When SV027 (SSF1)/ bitB, A (ovs)=11 Use this to perform the overshooting compensation during circular cutting or the feed forward control. The setting method is the same in Type 2.

When you wish different compensation amount depending on the direction When SV042 (OVS2) is “0”, compensate with the value of SV031 (OVS1) in both of the + and -directions. If you wish to change the compensation amount depending on the command direction, set this and SV042 (OVS2). (SV031: + direction, SV042: - direction. However, the directions may be opposite depending on other settings.) When “-1” is set, the compensation won’t be performed in the direction of the command.

2232 SV032 TOF

Torque offset Set the unbalance torque of vertical axis and inclined axis.

-100 to 100 (Stall [rated] current %)

Overshooting compensation 1

Page 124 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
Page 124 · click to enlarge
Page 124
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
Mitsubishi Electronics CNC Controller Board (C64) — 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) diagram (page 124)
Fig. 33 · 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

F E D C B A 9 8 dos hvx svx 7 6 5 4 3 2 1 0 nfd2 nf3 nfd1 zck

bit Meaning when “0” is set Meaning when “1” is set 0 zck Z phase check valid (Alarm 42) Z phase check invalid 1 Set the filter depth for Notch filter 1 (SV038).

2 Value 000 001 010 011 100 101 110 111

DeepÅ Æ Shallow 4 nf3 Notch filter 3 stop Notch filter 3 start (1125Hz) 5 Set the operation frequency of Notch filter 2 (SV046).

6 Value 000 001 010 011 100 101 110 111

8 svx Set the performance mode of the servo control. (Only for MDS-C1-Vx) 9 hvx

0. By current loop gain 01: MDS-B-Vx compatible mode selected 10: High gain mode selected 11: High gain mode selected
D 0MP scale absolute position detection, offset demand

(Note) Set to “0” for bits with no particular description.

Page 125 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
Page 125 · click to enlarge
Page 125
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
Mitsubishi Electronics CNC Controller Board (C64) — 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) diagram (page 125)
Fig. 34 · 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

F E D C B A 9 8 ovsn 7 6 5 4 3 2 1 0 os2 zeg mohn has2 has1

bit Meaning when “0” is set Meaning when “1” is set

0 has1 Setting for normal use (Except for HC)

HAS control 1 valid (HCHigh acceleration rate support)

1 has2 Setting for normal use (Except for HC)

Z phase normal edge detection (Setting for normal use)

Z phase reverse edge detection (Valid only when SV027/bit6=1)

6 os2 Setting for normal use Overspeed detection level changeover

Set the non-sensitive band of the overshooting compensation type 3 in increments of 2µm at a time. In the feed forward control, the non-sensitive band of the model position droop is set, and overshooting of the model is ignored. Set the same value as the standard SV040.

(Note) Set to “0” for bits with no particular description.

Page 126 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — E
Page 126 · click to enlarge
Page 126
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

No. Items Details Setting range

F E D C B A 9 8 clt clG1 cl2n clet cltq 7 6 5 4 3 2 1 0 ckab iup tdt

2235 SV035 SSF4

Servo function selection 4

bit Meaning when “0” is set Meaning when “1” is set 0 1

Td creation time setting Set to “0”. (For machine tool builder adjustment)

6 iup Set to “1” when using any of motors from HC152 to HC702 and from HC153 to HC453.

7 ckab Setting for normal use No signal 2 (Alarm 21) special detection

8 Set the retracting torque for collision detection in respect to the maximum torque of the motor. 9 cltq

0. 100% 01: 90% 10: 80% (Standard) 11: 70%

A clet Setting for normal use

The disturbance torque peak of the latest two seconds is displayed in MPOS of the servo monitor screen.

B cl2n Collision detection method 2

Collision detection method 2 invalid

C D

Collision detection method 1

Set the collision detection level during cutting feed (G1). The G1 collision detection level=SV060*clG1. When clG1=0, the collision detection method 1 during cutting feed won’t function.

E

F clt Setting for normal use

The guide value of the SV059 setting value is displayed in MPOS of the servo monitor screen.

(Note) bit7 (ckab) is only for MDS-C1-Vx.

tdt · valid · clG1

Page 127 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
Page 127 · click to enlarge
Page 127
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
Mitsubishi Electronics CNC Controller Board (C64) — 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible) diagram (page 127)
Fig. 35 · 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

F E D C B A 9 8 amp rtyp 7 6 5 4 3 2 1 0 ptyp

When the CN4 connector of the drive unit and the power supply are connected, setting below is necessary. To validate the external emergency stop function, add 40h.

3 Set- ting 0x 1x 2x 3x 4x 5x 6x 7x 8x

8 Set the regenerative resistor type when MDS-A-CR is used.

A 0 MDS-C1-CV (Setting when using power supply regeneration)

Set “the motor inertia + motor axis conversion load inertia” in respect to the motor inertia.

Set the vibration frequency to suppress if machine vibration occurs. (Valid at 36 or more) When not using, set to “0”.

Page 128 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2247 SV047 EC
Page 128 · click to enlarge
Page 128
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

No. Items Details Setting range

2239 SV039 LMCD

Lost motion compensation timing

Set this when the lost motion compensation timing doest not match. Adjust by increasing the value by 10 at a time.

0 to 2000 (ms)

The higher order 8bits and lower order 8bits are used for different functions. “Setting value of SV040” = (Icy*256) + LMCT

SV040 LMCT (Low order)

Lost motion compensation non-sensitive band

Set the non-sensitive band of the lost motion compensation in the feed forward control. When “0” is set, the actual value that is set is 2µm. Adjust by increasing by 1µm at a time.

0 to 100 (µm)

SV040 Icy (High order)

Current bias 2 Normally, set to “40” if you use HC202 to HC902, HC203 to HC703. Use this in combination with SV030 and the high order 8bits of SV045.

2241 SV041 LMC2

Lost motion compensation 2

Set this with SV016 (LMC1) only when you wish to set the lost motion compensation amount to be different depending on the command directions. Set to “0” as a standard.

-1 to 200 (Stall [rated] current %)

2242 SV042 OVS2

Set this with SV031 (OVS1) only when you wish to set the overshooting compensation amount to be different depending on the command directions. Set to “0” as a standard.

-1 to 100 (Stall [rated] current %)

2243 SV043 OBS1

Disturbance observer filter frequency

Set the disturbance observer filter band. Set to “100” as a standard. To use the disturbance observer, also set SV037 (JL) and SV044 (OBS2). When not using, set to “0”.

0 to 1000 (rad/s)

2244 SV044 OBS2

Set the disturbance observer gain. The standard setting is “100” to “300”. To use the disturbance observer, also set SV037 (JL) and SV043 (OBS1). When not using, set to “0”.

The higher order 8bits and lower order 8bits are used for different functions. “Setting value of SV045” = (Icy*256) + LMCT

SV045 TRUB (Low order)

When you use the collision detection function, set the frictional torque.

0 to 100 (Stall [rated] current %)

SV045 Ib1 (High order)

Current bias 3 Set to “0” as a standard. Use this in combination with SV030 and the high order 8bits of SV040.

Notch filter frequency 2

Set the vibration frequency to suppress if machine vibration occurs. (Valid at 36 or more) When not using, set to “0”.

0 to 9000 (Hz)

2247 SV047 EC

Inductive voltage compensation gain

Set the inductive voltage compensation gain. Set to “100” as a standard. If the current FB peak exceeds the current command peak, lower the gain.

Vertical axis drop prevention time

Input a length of time to prevent the vertical axis from dropping by delaying Ready OFF until the brake works when the emergency stop occurs. Increase the setting by 100ms at a time and set the value where the axis does not drop.

0 to 20000 (ms)

Show 5 more labels / short text on this page
Overshooting compensation 2 · Disturbance observer gain · Frictional torque · 2246 SV046 FHz2 · 2248 SV048 EMGrt
Page 129 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2253 SV053 OD3
Page 129 · click to enlarge
Page 129
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

No. Items Details Setting range

Position loop gain 1 in spindle synchronous control

Set the position loop gain during the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis).

1 to 200 (rad/s)

Set the same value as the value of the spindle parameter, position loop gain in synchronous control. When performing the SHG control, set this with SV050 (PGN2sp) and SV058 (SHGCsp).

2250 PGN2sp Position loop gain 2 in spindle synchronous control

Set this with SV049 (PGN1sp) and SV058 (SHGCsp) if you wish to perform the SHG control in the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis). When not performing the SHG control, set to “0”.

0 to 999 (rad/s)

2251 SV051 DFBT

Dual feed back control time constant

Set the control time constant in dual feed back. When “0” is set, the actual value that is set is 1ms. The higher the time constant is, the closer it gets to the semi-closed control, so the limit of the position loop gain is raised.

2252 SV052 DFBN

Dual feedback control non-sensitive band

Set the non-sensitive band in the dual feedback control. Set to “0” as a standard.

2253 SV053 OD3

Excessive error detection width in special control

Set the excessive error detection width when servo ON in a special control (initial absolute position setting, stopper control, etc.). If “0” is set, excessive error detection won’t be performed when servo ON during a special control.

0 to 32767 (mm)

2249 SV049 PGN1sp · (ms) · (µm)

Page 130 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2257 SV057 SHGC
Page 130 · click to enlarge
Page 130
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

No. Items Details Setting range

When SV035 (SSF4)/ bitF (ckab)=0

-1 to 32767 (mm)

SV054 ORE

Overrun detection width in closed loop control

Set the overrun detection width in the full-closed loop control. If the gap between the motor end detector and the linear scale (machine end detector) exceeds the value set by this parameter, it is judged to be overrun and Alarm 43 will be detected. When “-1” is set, the alarm detection won’t be performed. When “0” is set, overrun is detected with a 2mm width.

When SV035 (SSF4)/ bitF (ckab)=1

(Note) This applies to only MDS-C1-Vx.

The higher order 8bits and lower order 8bits are used for different functions. “Setting value of SV054” =(NSE*256)+ORE

SV054 ORE (Low order)

Overrun detection- width in closed loop control

Set the overrun detection width in the full-closed loop control. If the gap between the motor end detector and the linear scale (machine end detector) exceeds the value set by this parameter, it is judged to be overrun and Alarm 43 will be detected. When “255” is set, the alarm detection won’t be performed. When “0” is set, overrun is detected with a 2mm width.

0 to 255 (mm)

SV054 NSE (High order)

Special detection width for No signal 2

When SV035 (SSF4)/ bitF (ckab) =1, this setting is valid. Set the special detection width for No signal 2 (Alarm 21). When “0” is set, overrun is detected with a 15µm width.

0 to 127 (µm)

Max. gate off delay time after emergency stop

Set a length of time from the point when the emergency stop is input to the point when READY OFF is compulsorily executed. Normally, set the same value as the absolute value of SV056. In preventing the vertical axis from dropping, the gate off is delayed for the length of time set by SV048 if SV055’s value is smaller than that of SV048.

0 to 20000 (ms)

Deceleration time constant at emergency stop

In the vertical axis drop prevention time control, set the time constant used for the deceleration control at emergency stop. Set a length of time that takes from rapid traverse rate (rapid) to stopping. Normally, set the same value as the rapid traverse acceleration/deceleration time constant. When executing the synchronous operation, put the minus sign to the settings of both of the master axis and slave axis.

-20000 to 20000 (ms)

2257 SV057 SHGC

When performing the SHG control, set this with S003 (PGN1) and SV004 (PGN2). When not performing the SHG control, set to “0”.

0 to 1200 (rad/s)

2255 SV055 EMGx · 2256 SV056 EMGt · SHG control gain

Page 131 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2265 SV065 TLC
Page 131 · click to enlarge
Page 131
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

No. Items Details Setting range

SHG control gain in spindle synchronous control

Set this with SV049 (PGN1sp) and SV050 (PGN2sp) if you wish to perform the SHG control in the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis). When not performing the SHG control, set to “0”.

0 to 1200 (rad/s)

2259 SV059 TCNV

Collision detection torque estimating gain

Set the torque estimating gain when using the collision detection function. After setting as SV035/bitF(clt)=1 and performing acceleration/deceleration, set the value displayed in MPOS of the NC servo monitor screen. Set to “0” when not using the collision detection function.

2260 SV060 TLMT

When using the collision detection function, set the collision detection level during the G0 feeding. If “0” is set, none of the collision detection function will work.

(Stall [rated] current %)

2261 SV061 DA1NO

D/A output channel 1 data No.

Input the data number you wish to output to D/A output channel. In the case of MDS-C1-V2, set the axis on the side to which the data will not be output to “-1”.

2262 SV062 DA2NO

D/A output channel 2 data No.

2263 SV063 DA1MPY

D/A output channel 1 output scale

Set the scale with a 1/256 unit. When “0” is set, output is done with the standard output unit.

-32768 to 32767 (Unit1/256)

2264 SV064 DA2MPY

D/A output channel 2 output scale

2265 SV065 TLC

Tool end compensation spring constant

Set the spring constant of the tool end compensation. In the semi-closed loop control, the tool end compensation amount is calculated with the following equation.

F (mm/min)2*SV065

F: Commanded speed R: Radius

When not using, set to “0”.

Show 6 more labels / short text on this page
2258 SV058 SHGCsp · Collision detection level · Compensation · amount= · (µm) · R (mm)*109
Page 132 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
Page 132 · click to enlarge
Page 132
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

(2) Initial setting value

52 HC 102 HC 152 HC 202 HC 352 HC 452 HC 702 HC 902 Drive unit

capacity 05 10 20 20 35 45s 45 70s 70 90

SV001 PC1 - SV002 PC2 - SV003 PGN1 47 SV004 PGN2 0 SV005 VGN1 200 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 4096 SV010 IDA 4096 SV011 IQG 768 SV012 IDG 768 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 1000 0000 1000 0000 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xxB0 xxB1 xxB2 xxB3 xxB4 xx95 xxB5 xx96 xxB6 xxB7 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0

(a) HC**/HC**R series · Motor HC

Page 133 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
Page 133 · click to enlarge
Page 133
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

52 HC 102 HC 152 HC 202 HC 352 HC 452 HC 702 HC 902 Drive unit

capacity 05 10 20 20 35 45s 45 70s 70 90

SV033 SSF2 0000 SV034 SSF3 0003 SV035 SSF4 0000 0000 0040 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 0 0 10240 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 FHz2 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 TLC 0

Motor HC

Page 134 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
Page 134 · click to enlarge
Page 134
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

53 HC 103 HC 153 HC 203 HC 353 HC 453 HC 703 Drive unit

capacity 05 10 20 35 45s 45 70s 70 90

SV001 PC1 - SV002 PC2 - SV003 PGN1 47 SV004 PGN2 0 SV005 VGN1 200 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 4096 SV010 IDA 4096 SV011 IQG 768 SV012 IDG 768 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 1000 0000 1000 0000 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xxC0 xxC1 xxC2 xxC3 xxA4 xxC4 xxA5 xxC5 xxC6 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0

Motor HC

Page 135 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
Page 135 · click to enlarge
Page 135
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

53 HC 103 HC 153 HC 203 HC 353 HC 453 HC 703 Drive unit

capacity 05 10 20 35 45s 45 70s 70 90

SV033 SSF2 0000 SV034 SSF3 0003 SV035 SSF4 0000 0000 0040 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 0 0 10240 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 FHz2 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 TLC 0

Motor HC

Page 136 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
Page 136 · click to enlarge
Page 136
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

Motor HC 103R HC 153R HC 203R HC 353R Drive unit

capacity 10 10 20 35

SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 15 15 20 40 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 4096 SV010 IDA 4096 SV011 IQG 256 SV012 IDG 512 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xxE1 xxE2 xxE3 xxE4 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0

Page 137 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
Page 137 · click to enlarge
Page 137
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

Motor HC 103R HC 153R HC 203R HC 353R Drive unit

capacity 10 10 20 35

SV033 SSF2 0200 SV034 SSF3 0000 SV035 SSF4 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 FHz2 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 TLC 0

Page 138 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
Page 138 · click to enlarge
Page 138
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

Motor HA 40N HA 80N HA 100N HA 200N HA 300N HA 700N HA 900N Drive unit

capacity 05 10 20 35 45 70 90

SV001 PC1 - SV002 PC2 - SV003 PGN1 33 25 25 SV004 PGN2 0 SV005 VGN1 150 250 250 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 4096 SV010 IDA 4096 SV011 IQG 768 SV012 IDG 768 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xx00 xx01 xx02 xx03 xx04 xx05 xx06 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0

(b) HA**N series

Page 139 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
Page 139 · click to enlarge
Page 139
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

Motor HA 40N HA 80N HA 100N HA 200N HA 300N HA 700N HA 900N Drive unit

capacity 05 10 20 35 45 70 90

SV033 SSF2 0000 SV034 SSF3 0000 SV035 SSF4 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 FHz2 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 TLC 0

Page 140 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
Page 140 · click to enlarge
Page 140
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

Motor HA 43N HA 83N HA 93N HA 103N HA 203N HA 303N HA 703N HA 053N HA 13N HA 23N HA 33N Drive unit

capacity 05 10 20 35 45 70 90 01 01 03 03

SV001 PC1 - SV002 PC2 - SV003 PGN1 33 25 33 SV004 PGN2 0 SV005 VGN1 150 250 70 70 100 100 SV006 0 SV007 0 SV008 VIA 1364 SV009 IQA 4096 SV010 IDA 4096 SV011 IQG 768 SV012 IDG 768 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xx80 xx81 xx8A xx82 xx83 xx84 xx85 xx8C xx8D xx8E xx8F SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0

Page 141 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
Page 141 · click to enlarge
Page 141
7. Servo Parameters 7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)

Motor HA 43N HA 83N HA 93N HA 103N HA 203N HA 303N HA 703N HA 053N HA 13N HA 23N HA 33N Drive unit

capacity 05 10 20 35 45 70 90 01 01 03 03

SV033 SSF2 0000 SV034 SSF3 0000 SV035 SSF4 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 FHz2 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 TLC 0

Page 142 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — VGN2
Page 142 · click to enlarge
Page 142
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

(1) Details for servo parameters

For parameters marked with a (PR) in the table, turn the NC power OFF after setting. After the power is turned ON again, the parameter is validated.

! CAUTION

! In the explanation on bits, set all bits not used, including blank bits, to “0”.

No. Items Details Setting range

SV001 PC1

Motor side gear ratio

Set the motor side and machine side gear ratio. For the rotary axis, set the total deceleration (acceleration) ratio. Even if the gear ratio is within the setting range, the electronic gears may overflow and cause an alarm.

SV002 PC2

Machine side gear ratio

2203 SV003 PGN1

Position loop gain 1

Set the position loop gain. The standard setting is “33”. The higher the setting value is, the more precisely the command can be followed and the shorter the positioning time gets, however, note that a bigger shock is applied to the machine during acceleration/deceleration. When using the SHG control, also set SV004 (PGN2) and SV057 (SHGC).

1 to 200 (rad/s)

2204 SV004 PGN2

Position loop gain 2

When using the SHG control, also set SV003 (PGN1) and SV057 (SHGC). When not using the SHG control, set to “0”.

0 to 999 (rad/s)

2205 SV005 VGN1

Speed loop gain 1 Set the speed loop gain. Set this according to the load inertia size. The higher the setting value is, the more accurate the control will be, however, vibration tends to occur. If vibration occurs, adjust by lowering by 20 to 30%. The value should be determined to be 70 to 80% of the value at the time when the vibration stops.

2206 SV006

Speed loop gain 2 If the noise is bothersome at high speed during rapid traverse, etc, lower the speed loop gain. As in the right figure, set the speed loop gain of the speed 1.2 times as fast as the motor’s rated speed, and use this with SV029 (VCS). When not using, set to “0”.

VGN2

VGN1 VGN2

VCS VLMT 0

(Rated speed*1.2)

Page 143 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2212 SV012 IDG
Page 143 · click to enlarge
Page 143
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

No. Items Details Setting range

2207 SV007

Speed loop delay compensation

Set this when the limit cycle occurs in the full-closed loop, or overshooting occurs in positioning. Select the control method with SV027 (SSF1)/bit1, 0 (vcnt). Normally, use “Changeover type 2”. When you set this parameter, make sure to set the torque offset (SV032 (TOF)). When not using, set to “0”.

No changeover When SV027 (SSF1)/ bit1, 0 (vcnt)=00 The delay compensation control is always valid.

Changeover type 1 When SV027 (SSF1)/ bit1, 0 (vcnt)=01 The delay compensation control works when the command from the NC is “0”. Overshooting that occurs during pulse feeding can be suppressed.

Changeover type 2 When SV027 (SSF1)/ bit1, 0 (vcnt)=10 The delay compensation control works when the command from the NC is “0” and the position droop is “0”. Overshooting or the limit cycle that occurs during pulse feeding or positioning can be suppressed.

2208 SV008 VIA

Speed loop lead compensation

Set the gain of the speed loop integration control. The standard setting is “1364”. During the SHG control, the standard setting is “1900”. Adjust the value by increasing/decreasing it by about 100 at a time. Raise this value to improve contour tracking precision in high-speed cutting. Lower this value when the position droop vibrates (10 to 20Hz).

2209 SV009 IQA

Current loop q axis lead compensation

Set the gain of current loop. As this setting is determined by the motor’s electrical characteristics, the setting is fixed for each type of motor. Set the standard values for all the parameters depending on each motor type.

2210 SV010 IDA

Current loop d axis lead compensation

2211 SV011 IQG

Current loop q axis gain

2212 SV012 IDG

Current loop d axis gain

Page 144 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2216 SV016 LMC1
Page 144 · click to enlarge
Page 144
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

No. Items Details Setting range

2213 SV013 ILMT

Set the normal current (torque) limit value. (Limit values for both + and - direction.) When the value is “500” (a standard setting), the maximum torque is determined by the specification of the motor.

0 to 999 (Stall [rated] current %)

Current limit value in special control

Set the current (torque) limit value in a special control (initial absolute position setting, stopper control, etc). (Limit values for both of the + and - directions.) Set to “500” when not using.

0 to 999 (Stall [rated] current %)

2215 SV015 FFC

Acceleration rate feed forward gain

When a relative error in the synchronous control is large, apply this parameter to the axis that is delaying. The standard setting value is “0”. For the SHG control, set to “100”. To adjust a relative error in acceleration/deceleration, increase the value by 50 to 100 at a time.

2216 SV016 LMC1

Lost motion compensation 1

Set this when the protrusion (that occurs due to the non-sensitive band by friction, torsion, backlash, etc) at quadrant change is too large. This compensates the torque at quadrant change. This is valid only when the lost motion compensation (SV027 (SSF1/lmc)) is selected.

Type 1: When SV027 (SSF1)/ bit9, 8 (lmc)=01 Set the compensation amount based on the motor torque before the quadrant change. The standard setting is “100”. Setting to “0” means the compensation amount is zero. Normally, use Type 2.

Type 2: When SV027 (SSF1)/ bit9, 8 (lmc)=10 Set the compensation amount based on the stall (rated) current of the motor. The standard setting is double of the friction torque. Setting to “0” means the compensation amount is zero.

-1 to 100 (Stall [rated] current %)

When you wish different compensation amount depending on the direction When SV041 (LMC2) is “0”, compensate with the value of SV016 (LMC1) in both of the + and -directions. If you wish to change the compensation amount depending on the command direction, set this and SV041 (LMC2). (SV016: + direction, SV041: - direction. However, the directions may be opposite depending on other settings.) When “-1” is set, the compensation won’t be performed in the direction of the command.

Current limit value · 2214 SV014 ILMTsp

Page 145 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 145 · click to enlarge
Page 145
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Mitsubishi Electronics CNC Controller Board (C64) — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible) diagram (page 145)
Fig. 36 · 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compa…

F E D C B A 9 8 mpt3 mp

7 6 5 4 3 2 1 0 abs vdir fdir spwv seqh dfbx fdir2

bit Meaning when “0” is set Meaning when “1” is set

Speed feedback reverse polarity 1 dfbx Dual feedback control stop Dual feedback control start

2 seqh READY/Servo ON time normal READY/Servo ON time high speed

3 spwv Normal mode High gain servo synchronous mode

HA motor (4 pole motor) Detector installation position 90 degrees (B, D)

8 mp MP scale 360P (2mm pitch) MP scale 720P (1mm pitch)

9 mpt3 MP scale ABS detection type 1, 2 MP scale ABS detection type 3

(Note) Set to “0” for bits with no particular description.

Set the ball screw pitch. Set to “360” for the rotary axis. 1 to 32767

Page 146 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — OD1=OD2= 60*PGN1
Page 146 · click to enlarge
Page 146
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

No. Items Details Setting range

SV019 RNG1

In the case of the semi-closed loop control Set the same value as SV020 (RNG2). (Refer to the explanation of SV020.)

1 to 9999 (kp/rev)

In the case of the full-closed loop control Set the number of pulses per ball screw pitch.

1 to 9999 (kp/pit)

Detector model name Resolution SV019 setting OHE25K-ET, OHA25K-ET 100,000(p/rev) 100

OSE104-ET, OSA104-ET 100,000(p/rev) 100

OSE105-ET, OSA105-ET 1,000,000(p/rev) 1000

Refer to specification manual for each detector

Relative position detection scale

AT41 (Mitsutoyo) 1 (µm/p) The same as SV018 (PIT)

Refer to specification manual for each detector

FME type, FLE type (Futaba)

Refer to specification manual for each detector

MP type (Mitsubishi Heavy Industries)

AT342 (Mitsutoyo) 0.5 (µm/p) Twice as big as SV018 (PIT)

SV020 RNG2

Set the number of pulses per one revolution of the motor end detector.

1 to 9999 (kp/rev)

Detector model name SV020 setting

Equipped to HA053, HA13 (Only for

OHE25K, OHA25K (Only for

OSE104, OSA104 100

OSE105, OSA105 1000

2221 SV021 OLT

Overload detection time constant

Set the detection time constant of Overload 1 (Alarm 50). Set to “60” as a standard. (For machine tool builder adjustment.)

1 to 999 (s)

2222 SV022 OLL

Set the current detection level of Overload 1 (Alarm 50) in respect to the stall (rated) current. Set to “150” as a standard. (For machine tool builder adjustment.)

110 to 500 (Stall [rated] current %)

2223 SV023 OD1

Excessive error detection width during servo ON

Set the excessive error detection width when servo ON.

0 to 32767 (mm)

OD1=OD2= 60*PGN1

When “0” is set, the excessive error detection will not be performed.

Show 12 more labels / short text on this page
Position detector resolution · PIT/Resolution (µm) · PIT/Resolution (µm) · PIT/Resolution (µm) · Speed detector resolution · MDS-B-Vx) 10 · MDS-B-Vx) 100 · Overload detection level · <Standard setting value> · Rapid traverse rate · (mm/min) · /2 (mm)
Page 147 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 147 · click to enlarge
Page 147
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Mitsubishi Electronics CNC Controller Board (C64) — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible) diagram (page 147)
Fig. 37 · 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compa…

Set the in-position detection width. Set the accuracy required for the machine. The lower the setting is, the higher the positioning accuracy gets, however, the cycle time (setting time) becomes longer. The standard setting is “50”.

F E D C B A 9 8 pen ent

7 6 5 4 3 2 1 0 mtyp

1 Set- ting 0x 1x 2x 3x 4x 5x 6x 7x

Set- ting 8x 9x Ax Bx Cx Dx Ex Fx

Page 148 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 148 · click to enlarge
Page 148
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Mitsubishi Electronics CNC Controller Board (C64) — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible) diagram (page 148)
Fig. 38 · 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compa…

No. Items Details Setting range (Continued from the previous page)

Set the detector type. Set position detector type for “pen”, and speed detector type for “ent”. In the case of the semi-closed loop control, set the same value for “pen” and “ent”.

3 3 Equipped to HA053, HA13 (Only for MDS-B-Vx)

Relative position detection scale, MP type (Mitsubishi Heavy Industries)

The setting of the slave axis in the speed/current synchronization control. When the master axis is the semi-closed control.

Set the excessive error detection width when servo ON. For the standard setting, refer to the explanation of SV023 (OD1). When “0” is set, the excessive error detection will not be performed.

Page 149 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — VCS
Page 149 · click to enlarge
Page 149
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

No. Items Details Setting range

F E D C B A 9 8 aflt zrn2 afse ovs lmc

2227 SV027 SSF1

Servo function selection 1

7 6 5 4 3 2 1 0 zrn3 vfct upc vcnt

bit Meaning when “0” is set Meaning when “1” is set

0 vcnt Set the execution changeover type of the speed loop delay compensation. 1

0. Delay compensation changeover invalid 01: Delay compensation changeover type 1 10: Delay compensation type 2 11: Setting prohibited

2 upc Start torque compensation invalid

Start torque compensation valid

4 Set the number of compensation pulses of the jitter compensation. 5 vfct

0. Jitter compensation invalid 01: Jitter compensation 1 pulse 10: Jitter compensation 2 pulses 11: Jitter compensation 3 pulses

6 zrn3 ABS scale: Set to “1” in using AT342, AT343, LC191M/491M.

8 Set the compensation amount with SV016 (LMC1) and SV041 (LMC2). 9 lmc

0. Lost motion compensation stop 01: Lost motion compensation type 1 10: Lost motion compensation type 2 11: Setting prohibited

A Set the compensation amount with SV031 (OVS1) and SV042 (OVS2).

B

0. Overshooting compensation stop 01: Overshooting compensation type 1 10: Overshooting compensation type 2 11: Overshooting compensation type 3 C 00: Adoptive filter sensitivity standard D afse 11: Adoptive filter sensitivity increase (Set 2bits at a time)

E zrn2 Set to “1”.

F aflt Adoptive filter stops Adoptive filter starts

(Note) Set to “0” for bits with no particular description.

2228 SV028 Not used. Set to “0”. 0

2229 SV029

Speed at the change of speed loop gain

If the noise is bothersome at high speed during rapid traverse, etc, lower the speed loop gain. Set the speed at which the speed loop gain changes, and use this with SV006 (VGN2). (Refer to SV006.) When not using, set to “0”.

0 to 9999 (r/min)

VCS

ovs

Page 150 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2231 SV031 OVS1
Page 150 · click to enlarge
Page 150
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

No. Items Details Setting range

The higher order 8bits and lower order 8bits are used for different functions. “The setting value of SV030” = (Icx*256) + IVC

SV030 IVC (Low order)

Voltage dead time compensation

When 100% is set, the voltage equivalent to the logical non-energized time will be compensated. When “0” is set, a 100% compensation will be performed. Adjust in increments of 10% from the default value 100%. If increased too much, vibration or vibration noise may be generated.

SV030 Icx (High order)

Current bias 1 Set to “0” as a standard. Use this in combination with SV040 and the high order 8bits of SV045.

2231 SV031 OVS1

Set this if overshooting occurs during positioning. This compensates the motor torque during positioning. This is valid only when the overshooting compensation SV027 (SSF1/ovs) is selected.

-1 to 100 (Stall [rated] current%)

Type 1: When SV027 (SSF1)/ bitB, A (ovs)=01 Set the compensation amount based on the motor’s stall current. This compensates overshooting that occurs during pulse feeding. Normally, use Type 2.

Type 2: When SV027 (SSF1)/ bitB, A (ovs)=10 Set the compensation amount based on the motor’s stall current. Increase by 1% and determine the amount that overshooting doesn’t occur. In Type 2, compensation during the feed forward control during circular cutting won’t be performed.

Type 3: When SV027 (SSF1)/ bitB, A (ovs)=11 Use this to perform the overshooting compensation during circular cutting or the feed forward control. The setting method is the same in Type 2.

When you wish different compensation amount depending on the direction When SV042 (OVS2) is “0”, compensate with the value of SV031 (OVS1) in both of the + and -directions. If you wish to change the compensation amount depending on the command direction, set this and SV042 (OVS2). (SV031: + direction, SV042: - direction. However, the directions may be opposite depending on other settings.) When “-1” is set, the compensation won’t be performed in the direction of the command.

Overshooting compensation 1

Page 151 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 151 · click to enlarge
Page 151
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Mitsubishi Electronics CNC Controller Board (C64) — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible) diagram (page 151)
Fig. 39 · 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compa…

Set the unbalance torque of vertical axis and inclined axis.

bit Meaning when “0” is set Meaning when “1” is set

0 zck Z phase check valid (Alarm 42) Z phase check invalid

1 nfd1 Set the filter depth for Notch filter 1 (SV038).

2 Value 000 001 010 011 100 101 110 111

4 Set the operation frequency of Notch filter 2.

Set the performance mode of the servo control. (Only for MDS-C1-Vx)

D dos 0MP scale absolute position detection, offset demand signal output

(Note) Set to “0” for bits with no particular description.

Page 152 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 152 · click to enlarge
Page 152
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Mitsubishi Electronics CNC Controller Board (C64) — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible) diagram (page 152)
Fig. 40 · 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compa…

F E D C B A 9 8 ovsn

7 6 5 4 3 2 1 0 os2 zeg has2 has1

bit Meaning when “0” is set Meaning when “1” is set 0 has1 Setting for normal use HAS control 1 valid

1 has2 Setting for normal use HAS control 2 valid

5 zeg Z phase normal edge detection Z phase reverse edge detection

6 os2 Setting for normal use Overspeed detection level changeover

Set the non-sensitive band of the overshooting compensation type 3 in increments of 2µm at a time. In the feed forward control, the non-sensitive band of the model position droop is set, and overshooting of the model is ignored. Set the same value as the standard SV040.

(Note) Set to “0” for bits with no particular description.

Page 153 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — E
Page 153 · click to enlarge
Page 153
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

No. Items Details Setting range

F E D C B A 9 8 clt clG1 cl2n clet cltq

2235 SV035 SSF4

7 6 5 4 3 2 1 0 iup tdt

bit Meaning when “0” is set Meaning when “1” is set 0 Td creation time setting 1 Set to “0”. (For machine tool builder adjustment)

6 iup Set to “1” in the case of any motors from HC152 to HC702 and from HC153 to HC453.

8 Set the retracting torque for collision detection in respect to the maximum torque of the motor. 9 cltq

0. 100% 01: 90% 10: 80% (Standard) 11: 70%

A

Setting for normal use

The disturbance torque peak of the latest two seconds is displayed in MPOS of the servo monitor screen.

B cl2n Collision detection method 2

valid Collision detection method 2 invalid

C D

Collision detection method 1 Set the collision detection level during cutting feed (G1). The G1 collision detection level=SV060*clG1. When clG1=0, the collision detection method 1 during cutting feed won’t function.

E

Setting for normal use The guide value of the SV059 setting value is displayed in MPOS of the servo monitor screen.

(Note) Set to “0” for bits with no particular description.

Show 5 more labels / short text on this page
Servo function selection4 · tdt · clet · clG1 · F clt
Page 154 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 154 · click to enlarge
Page 154
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Mitsubishi Electronics CNC Controller Board (C64) — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible) diagram (page 154)
Fig. 41 · 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compa…

F E D C B A 9 8 amp rtyp

7 6 5 4 3 2 1 0 ptyp

When the CN4 connector of the drive unit and the power supply are connected, setting below is necessary. To validate the external emergency stop function, add 40h.

3 Set- ting 0x 1x 2x 3x 4x 5x 6x7x 8x

8 Set the regenerative resistor type when MDS-A-CR is used.

A 0 MDS-C1-CV (Setting when using power supply regeneration)

Page 155 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2244 SV044 OBS2
Page 155 · click to enlarge
Page 155
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

No. Items Details Setting range

2237 SV037 JL Load inertia scale

Set “the motor inertia + motor axis conversion load inertia” in respect to the motor inertia.

SV037 (JL) =

JmMotor inertia
JlMotor axis conversion load inertia

Notch filter frequency 1

Set the vibration frequency to suppress if machine vibration occurs. (Valid at 72 or more) When not using, set to “0”.

2239 SV039 LMCD

Lost motion compensation timing

Set this when the lost motion compensation timing doest not match. Adjust by increasing the value by 10 at a time.

The higher order 8bits and lower order 8bits are used for different functions. “Setting value of SV040” = (Icy*256) + LMCT

SV040 LMCT

Lost motion compensation non-sensitive band

Set the non-sensitive band of the lost motion compensation in the feed forward control. When “0” is set, the actual value that is set is 2µm. Adjust by increasing by 1µm at a time.

0 to 100 (µm)

Current bias 2 Normally, set to “40” if you use HC202 to HC902, HC203 to HC703. Use this in combination with SV030 and the high order 8bits of SV045.

2241 SV041 LMC2

Lost motion compensation 2

Set this with SV016 (LMC1) only when you wish to set the lost motion compensation amount to be different depending on the command directions. Set to “0” as a standard.

-1 to 200 (Stall [rated] current %)

2242 SV042 OVS2

Set this with SV031 (OVS1) only when you wish to set the overshooting compensation amount to be different depending on the command directions. Set to “0” as a standard.

-1 to 100 (Stall [rated] current %)

2243 SV043 OBS1

Disturbance observer filter frequency

Set the disturbance observer filter band. Set to “100” as a standard. To use the disturbance observer, also set SV037 (JL) and SV044 (OBS2). When not using, set to “0”.

0 to 1000 (rad/s)

2244 SV044 OBS2

Set the disturbance observer gain. The standard setting is “100” to “300”. To use the disturbance observer, also set SV037 (JL) and SV043 (OBS1). When not using, set to “0”.

The higher order 8bits and lower order 8bits are used for different functions. “Setting value of SV045” = (Icy*256) + LMCT

SV045 TRUB (Low order)

When you use the collision detection function, set the frictional torque.

0 to 100 (Stall [rated] current %)

SV045 Ib1 (High order)

Current bias 3 Set to “0” as a standard. Use this in combination with SV030 and the high order 8bits of SV040.

Show 12 more labels / short text on this page
Jl+Jm · *100 · Jm · 2238 SV038 FHz1 · (Hz) · (ms) · (Low order) · SV040 Icy · (High order) · Overshooting compensation 2 · Disturbance observer gain · Frictional torque
Page 156 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2254 SV054 ORE
Page 156 · click to enlarge
Page 156
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

No. Items Details Setting range

2246 SV046 Not used. Set to “0”. 0

2247 SV047 EC

Inductive voltage compensation gain

Set the inductive voltage compensation gain. Set to “100” as a standard. If the current FB peak exceeds the current command peak, lower the gain.

Vertical axis drop prevention time

Input a length of time to prevent the vertical axis from dropping by delaying Ready OFF until the brake works when the emergency stop occurs. Increase the setting by 100ms at a time and set the value where the axis does not drop.

0 to 20000 (ms)

Position loop gain 1 in spindle synchronous control

Set the position loop gain during the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis). Set the same value as the value of the spindle parameter, position loop gain in synchronous control. When performing the SHG control, set this with SV050 (PGN2sp) and SV058 (SHGCsp).

1 to 200 (rad/s)

2250 PGN2sp Position loop gain 2 in spindle synchronous control

Set this with SV049 (PGN1sp) and SV058 (SHGCsp) if you wish to perform the SHG control in the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis). When not performing the SHG control, set to “0”.

0 to 999 (rad/s)

2251 SV051 DFBT

Dual feed back control time constant

Set the control time constant in dual feed back. When “0” is set, the actual value that is set is 1ms. The higher the time constant is, the closer it gets to the semi-closed control, so the limit of the position loop gain is raised.

0 to 9999 (ms)

2252 SV052 DFBN

Dual feedback control non-sensitive band

Set the non-sensitive band in the dual feedback control. Set to “0” as a standard.

0 to 9999 (µm)

2253 SV053 OD3

Excessive error detection width in special control

Set the excessive error detection width when servo ON in a special control (initial absolute position setting, stopper control, etc.). If “0” is set, excessive error detection won’t be performed when servo ON during a special control.

0 to 32767 (mm)

2254 SV054 ORE

Overrun detection width in closed loop control

Set the overrun detection width in the full-closed loop control. If the gap between the motor end detector and the linear scale (machine end detector) exceeds the value set by this parameter, it is judged to be overrun and Alarm 43 will be detected. When “-1” is set, the alarm detection won’t be performed. When “0” is set, overrun is detected with a 2mm width.

-1 to 32767 (mm)

2248 SV048 EMGrt · 2249 SV049 PGN1sp

Page 157 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 2264 SV064 DA2MPY
Page 157 · click to enlarge
Page 157
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

No. Items Details Setting range

Max. gate off delay time after emergency stop

Set a length of time from the point when the emergency stop is input to the point when READY OFF is compulsorily executed. Normally, set the same value as the absolute value of SV056. In preventing the vertical axis from dropping, the gate off is delayed for the length of time set by SV048 if SV055’s value is smaller than that of SV048.

0 to 20000 (ms)

Deceleration time constant at emergency stop

In the vertical axis drop prevention control, set the time constant used for the deceleration control at emergency stop. Set a length of time that takes from rapid traverse rate (rapid) to stopping. Normally, set the same value as the rapid traverse acceleration/deceleration time constant. When executing the synchronous operation, put the minus sign to the settings of both of the master axis and slave axis.

-20000 to 20000 (ms)

2257 SV057 SHGC

When performing the SHG control, set this with S003 (PGN1) and SV004 (PGN2). When not performing the SHG control, set to “0”.

0 to 999 (rad/s)

SHG control gain in spindle synchronous control

Set this with SV049 (PGN1sp) and SV050 (PGN2sp) if you wish to perform the SHG control in the spindle synchronous control (synchronous tapping, synchronous control with spindle/C axis). When not performing the SHG control, set to “0”.

0 to 999 (rad/s)

2259 SV059 TCNV

Collision detection torque estimating gain

Set the torque estimating gain when using the collision detection function. After setting as SV035/bitF(clt)=1 and performing acceleration/deceleration, set the value displayed in MPOS of the NC servo monitor screen. Set to “0” when not using the collision detection function.

2260 SV060 TLMT

When using the collision detection function, set the collision detection level during the G0 feeding. If “0” is set, none of the collision detection function will work.

0 to 999 (Stall [rated] current %)

2261 SV061 DA1NO

D/A output channel 1 data No.

Input the data number you wish to output to D/A output channel. In the case of MDS-C1-V2, set the axis on the side to which the data will not be output to “-1”.

2262 SV062 DA2NO

D/A output channel 2 data No.

2263 SV063 DA1MPY

D/A output channel 1 output scale

Set the scale with a 1/256 unit. When “0” is set, output is done with the standard output unit.

-32768 to 32767 (Unit1/256)

2264 SV064 DA2MPY

D/A output channel 2 output scale

2265 SV065 Not used. Set to “0”. 0

Show 5 more labels / short text on this page
2255 SV055 EMGx · 2256 SV056 EMGt · SHG control gain · 2258 SV058 SHGCsp · Collision detection level
Page 158 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 158 · click to enlarge
Page 158
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

(2) Initial setting value

52 HC 102 HC 152 HC 202 HC 352 HC 452 HC 702 HC 902 Drive unit

capacity 05 10 20 20 35 45 70 90

SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 100 150 150 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 2048 SV010 IDA 2048 SV011 IQG 512 512 512 256 256 256 200 200 SV012 IDG 512 256 256 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xxB0 xxB1 xxB2 xxB3 xxB4 xxB5 xxB6 xxB7 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0

(a) HC**/HC**R series · Motor HC

Page 159 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 159 · click to enlarge
Page 159
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

52 HC 102 HC 152 HC 202 HC 352 HC 452 HC 702 HC 902 Drive unit

capacity 05 10 20 20 35 45 70 90

SV033 SSF2 0000 SV034 SSF3 0003 SV035 SSF4 0000 0000 0040 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 0 0 10240 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0

Motor HC

Page 160 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 160 · click to enlarge
Page 160
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

53 HC 103 HC 153 HC 203 HC 353 HC 453 HC 703 HC 103R HC 153R HC 203R HC 353R Drive unit

capacity 05 10 20 35 45 70 90 10 10 20 35

SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 100 15 15 20 40 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 2048 4096 SV010 IDA 2048 4096 SV011 IQG 256 SV012 IDG 512 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xxC0 xxC1 xxC2 xxC3 xxC4 xxC5 xxC6 xxE1 xxE2 xxE3 xxE4 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0

Motor HC

Page 161 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 161 · click to enlarge
Page 161
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

53 HC 103 HC 153 HC 203 HC 353 HC 453 HC 703 HC 103R HC 153R HC 203R HC 353R Drive unit

capacity 05 10 20 35 45 70 90 10 10 20 35

SV033 SSF2 0000 SV034 SSF3 0003 0000 SV035 SSF4 0000 0000 0040 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0

SV040 LMCT 0 0 0 1024 0 1024 0 1024 0 1024 0

SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0

Motor HC

Page 162 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 162 · click to enlarge
Page 162
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

Motor HA 40N HA 80N HA 100N HA 200N HA 300N HA 700N HA 900N Drive unit

capacity 05 10 20 35 45 70 90

SV001 PC1 - SV002 PC2 - SV003 PGN1 33 25 25 SV004 PGN2 0 SV005 VGN1 150 250 250 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 2048 SV010 IDA 2048 SV011 IQG 512 512 256 256 256 200 200 SV012 IDG 512 256 256 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xx00 xx01 xx02 xx03 xx04 xx05 xx06 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0

(b) HA**N series

Page 163 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 163 · click to enlarge
Page 163
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

Motor HA 40N HA 80N HA 100N HA 200N HA 300N HA 700N HA 900N Drive unit

capacity 05 10 20 35 45 70 90

SV033 SSF2 0000 SV034 SSF3 0000 SV035 SSF4 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0

Page 164 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 164 · click to enlarge
Page 164
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

Motor HA 43N HA 83N HA 93N HA 103N HA 203N HA 303N HA 703N Drive unit

capacity 05 10 20 35 45 70 90

SV001 PC1 - SV002 PC2 - SV003 PGN1 33 25 SV004 PGN2 0 SV005 VGN1 150 250 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 2048 SV010 IDA 2048 SV011 IQG 256 200 SV012 IDG 512 256 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xx80 xx81 xx8A xx82 xx83 xx84 xx85 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0

Page 165 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 165 · click to enlarge
Page 165
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

Motor HA 43N HA 83N HA 93N HA 103N HA 203N HA 303N HA 703N Drive unit

capacity 05 10 20 35 45 70 90

SV033 SSF2 0000 SV034 SSF3 0000 SV035 SSF4 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0

Page 166 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 166 · click to enlarge
Page 166
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

13 HA 053N HA 13N HA 23N HA 33N Drive unit

Motor HA 053 HA

capacity 01 03 03

SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 70 100 100 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 2048 SV010 IDA 2048 SV011 IQG 256 224 224 SV012 IDG 256 224 224 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 10 10 - SV020 RNG2 10 10 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP 338C 338D xx8C xx8D xx8E xx8F SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0 (Note) The HA053 and HA13 are dedicated for the MDS-B-Vx.

Page 167 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 167 · click to enlarge
Page 167
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

13 HA 053N HA 13N HA 23N HA 33N Drive unit

Motor HA 053 HA

capacity 01 03 03

SV033 SSF2 0000 SV034 SSF3 0000 SV035 SSF4 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0 (Note) The HA053 and HA13 are dedicated for the MDS-B-Vx.

Page 168 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 168 · click to enlarge
Page 168
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

Motor HA 50L HA 100L HA 150L HA 200L HA 300L HA 500L HA- A11KL

capacity 05 10 10 20 35 45 110 150

SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 30 50 150 150 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 2048 SV010 IDA 2048 SV011 IQG 512 256 256 512 512 SV012 IDG 512 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 3 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xx20 xx21 xx2A xx22 xx23 xx24 xx27 xx28 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0

(c) HA**L series · HA- A15KL Drive unit

Page 169 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 169 · click to enlarge
Page 169
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

Motor HA 50L HA 100L HA 150L HA 200L HA 300L HA 500L HA- A11KL

capacity 05 10 10 20 35 45 110 150

SV033 SSF2 0000 SV034 SSF3 0000 SV035 SSF4 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0

HA- A15KL Drive unit

Page 170 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 170 · click to enlarge
Page 170
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

Motor HA 53L HA 103L HA 153L HA 203L HA 303L HA 503L Drive unit

capacity 10 20 20 35 45 70

SV001 PC1 - SV002 PC2 - SV003 PGN1 33 SV004 PGN2 0 SV005 VGN1 30 50 SV006 VGN2 0 SV007 VIL 0 SV008 VIA 1364 SV009 IQA 2048 SV010 IDA 2048 SV011 IQG 512 256 256 SV012 IDG 512 SV013 ILMT 500 SV014 ILMTsp 500 SV015 FFC 0 SV016 LMC1 0 SV017 SPEC 0000 SV018 PIT - SV019 RNG1 - SV020 RNG2 - SV021 OLT 60 SV022 OLL 150 SV023 OD1 6 SV024 INP 50 SV025 MTYP xx30 xx31 xx3A xx32 xx33 xx34 SV026 OD2 6 SV027 SSF1 4000 SV028 0 SV029 VCS 0 SV030 IVC 0 SV031 OVS1 0 SV032 TOF 0 SV033 SSF2 0000

Page 171 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
Page 171 · click to enlarge
Page 171
7. Servo Parameters 7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)

Motor HA 53L HA 103L HA 153L HA 203L HA 303L HA 503L Drive unit

capacity 10 20 20 35 45 70

SV034 SSF3 0000 SV035 SSF4 0000 SV036 PTYP 0000 SV037 JL 0 SV038 FHz1 0 SV039 LMCD 0 SV040 LMCT 0 SV041 LMC2 0 SV042 OVS2 0 SV043 OBS1 0 SV044 OBS2 0 SV045 TRUB 0 SV046 0 SV047 EC 100 SV048 EMGrt 0 SV049 PGN1sp 15 SV050 PGN2sp 0 SV051 DFBT 0 SV052 DFBN 0 SV053 OD3 0 SV054 ORE 0 SV055 EMGx 0 SV056 EMGt 0 SV057 SHGC 0 SV058 SHGCsp 0 SV059 TCNV 0 SV060 TLMT 0 SV061 DA1NO 0 SV062 DA2NO 0 SV063 DA1MPY 0 SV064 DA2MPY 0 SV065 0

Page 172 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.4 Supplement 7.4.1 D/A Output Specifications
Page 172 · click to enlarge
Page 172
7. Servo Parameters 7.4 Supplement

7.4 Supplement 7.4.1 D/A Output Specifications

(1) MDS-B-SVJ2

(a) D/A output specifications

Mitsubishi Electronics CNC Controller Board (C64) — 7.4 Supplement 7.4.1 D/A Output Specifications diagram (page 172)
Fig. 42 · 7.4 Supplement 7.4.1 D/A Output Specifications

Item Explanation No. of channels 2ch Output cycle 888µs (min. value) Output precision 8bit Output voltage range

GND = pin 1,11 Function Offset amount adjustment function Output clamp function Low path filter function Option Relay terminal: MR-J2CN3TM Connect from the CN3 connector using the SH21 cable as a lead-in wire. CN3 Connector Pin Signal Pin Signal

Mitsubishi Electronics CNC Controller Board (C64) — 7.4 Supplement 7.4.1 D/A Output Specifications diagram (page 172)
Fig. 43 · 7.4 Supplement 7.4.1 D/A Output Specifications

1 LG 11 LG 2 12 3 SG 13 MBR 4 MO1 14 MO2 5 COM 15 MC 6 16 7 17 8 18 9 19 10 VDD 20 EMGX

Page 173 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.4 Supplement
Page 173 · click to enlarge
Page 173
7. Servo Parameters 7.4 Supplement

(b) Setting the output data

Set the No. of the data to be outputted to each D/A output channel.

# No. Abbrev Parameter name 2261 SV061 DA1NO D/A output channel 1 data No. 2262 SV062 DA2NO D/A output channel 2 data No.

No. Output data Standard output unit

cycle 0 0V test output For offset amount adjustment 1 Speed feedback 1000rpm / 2V 888µs

2 Current feedback Stall (rated)

100% / 2V 888µs

3 Speed command 1000rpm / 2V 888µs

4 Current command Stall (rated)

100% / 2V 888µs

5 V-phase current value 10A / V 888µs 6 W-phase current-value 10A / V 888µs

7 Estimated disturbance torque Stall (rated)

100% / 2V 888µs

8 Collision detection disturbance torque

100% / 2V 888µs

9 Position feedback (stroke) 100mm / V 3.55ms 10 Position feedback (pulse) 10µm / V 3.55ms 11 Position droop mm / V 3.55ms 12 Position droop (x10) 100µm / V 3.55ms 13 Position droop (x100) 10µm / V 3.55ms 14 Feedrate (F∆T) 10000(mm/min) / V 888µs 15 Feedrate (F∆T x 10) 1000(mm/min) / V 888µs 16 Model position droop mm / V 3.55ms 17 Model position droop (x10) 100µm / V 3.55ms 18 Model position droop (x100) 10µm / V 3.55ms 19 q-axis current cumulative value – 888µs 20 d-axis current cumulative value – 888µs 21 Motor load level 100% / 5V 113.7ms 22 Amplifier load level 100% / 5V 113.7ms 23 Regenerative load level 100% / 5V 910.2ms 24 PN bus wire voltage 50V / V (1/50) 888µs 25 Speed cumulative item – 888µs

26 Cycle counter 0-5V (Regardless of resolution) 888µs

27 Excessive error detection amount mm / V 3.55ms

28 Collision detection estimated torque

100% / 2V 888µs

29 Position command (stroke) 100mm / V 3.55ms 30 Position command (pulse) 10µm / V 3.55ms 31 to 99 - 100 5V test output - -

101 Saw-tooth wave test output -5 to 5V Cycle: 113.7ms 888µs

102 Rectangular wave test output 0 to 5V Cycle: 227.5ms 888µs

103 to Setting prohibited

Output · Stall (rated) · Stall (rated)

Page 174 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.4 Supplement
Page 174 · click to enlarge
Page 174
7. Servo Parameters 7.4 Supplement

(c) Setting the output scale

When “0“ is set, the output will be made with the standard output unit. To change the output unit, set a value other than “0”. The scale is set with a 1/256 unit. When 256 is set, the unit will be the same as the standard output.

# No. Abbrev Parameter name 2263 SV063 DA1MPY D/A output channel 1 output scale 2264 SV064 DA2MPY D/A output channel 2 output scale (Example 1) When SV061 = 5, SV063 = 2560

The V-phase current value will be output with 1 A/V unit to D/A output ch.1. (Example 2) When SV063 = 11, SV064 = 128

The position droop will be output with a 2mm/Vunit to D/A output ch.2.

Page 175 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.4 Supplement
Page 175 · click to enlarge
Page 175
7. Servo Parameters 7.4 Supplement

(2) MDS-C1-Vx, MDS-B-Vx, MDS-B-Vx4

(a) D/A Output specifications

Mitsubishi Electronics CNC Controller Board (C64) — 7.4 Supplement diagram (page 175)
Fig. 44 · 7.4 Supplement

Item Explanation No. of channels 2ch Output cycle 888µs (min. value) Output precision 8bit Output voltage 0V to 2.5V to +5V Output scale setting

CN9 connector MO1 = pin 9 MO2 = pin 19

GND = pin 1,11 Phase current feed back output function L-axis U-phase current FB : pin 7 L-axis V-phase current FB : pin 17 M-axis U-phase current FB : pin 6

M-axis V-phase current FB : pin 16 Option An drive unit with 2 axes also has 2 channels for D/A output. Therefore, set the output data of the axis (SV061,62), which is not observed, to “-1”.

Mitsubishi Electronics CNC Controller Board (C64) — 7.4 Supplement diagram (page 175)
Fig. 45 · 7.4 Supplement

1 LG 11 LG 2 12 3 13 4 14 5 15 6 MUIFB 16 MVIFB 7 LUIFB 17 LVIFB 8 18 9 MO1 19 MO2 10 20

Page 176 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.4 Supplement
Page 176 · click to enlarge
Page 176
7. Servo Parameters 7.4 Supplement

(b) Setting the output data

Set the No. of the data to be outputted to each data D/A output channel.

Mitsubishi Electronics CNC Controller Board (C64) — 7.4 Supplement diagram (page 176)
Fig. 46 · 7.4 Supplement

# No. Abbrev Parameter name 2261 SV061 DA1NO D/A output channel 1 data No. 2262 SV062 DA2NO D/A output channel 2 data No.

For a drive unit. with 2 axes (MDS-C1-V2). Set for the parameter of the axis which is not used.

ch2Current command Stall% 131 Stall 100% / V 3.55ms

1 Current command Stall% 131 Stall 100% / V 3.55ms 2 – 3 Current feedback Stall% 131 Stall 100% / V 3.55ms 4 – 5 –

14 Collision detection estimated torque Stall% 131 Stall 100% / V 3.55ms

15 Collision detection disturbance torque Stall% 131 Stall 100% / V 3.55ms

(To be continued to the next page)

Page 177 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SV063, SV064)
Page 177 · click to enlarge
Page 177
7. Servo Parameters 7.4 Supplement

(Continued from the previous page)

No. Output data Standard output

scale (Setting values in

SV063, SV064)

77 Estimated disturbance torque Internal unit

125 Saw-tooth wave test output 0V to 5V 0 (256) Cycle: 227.5ms 888µs

126 Rectangular wave test output 0V to 5V 0 (256) Cycle: 1.7ms 888µs

127 2.5V (data 0) test output 2.5V 0 (256) – 888µs

(c) Setting the output scale

# No. Abbrev Parameter name 2263 SV063 DA1MPY D/A output channel 1 output scale 2264 SV064 DA2MPY D/A output channel 2 output scale Usually, the standard setting value is set for the output scale (SV063, SV 064). When “0” is set, the output will be made as well as when “256” is set.

SV063 5 [V] DATA x 256 x 256 (8bit) + 2.5 [V] (offset) = Output voltage [V]

(Example) When outputting the current FB with 100%/V–stall (SV061=3, SV063=131)

131 5 100 x 256 x 256 + 2.5 = 3.499 [V]

Show 9 more labels / short text on this page
Standard setting · value of output · Standard output unit · Output · unit · cycle · 8 (adjustment · – 888µs · required)
Page 178 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — ELG1 ≤ 32767
Page 178 · click to enlarge
Page 178
7. Servo Parameters 7.4 Supplement

7.4.2 Electronic Gears

The servo drive unit has internal electronic gears. The command value from the NC is converted into a detector resolution unit to carry out position control. The electronic gears are single gear ratios calculated from multiple parameters as shown below. However, each value (ELG1, ELG2) must be less than 32767.

If the value overflows, the initial parameter error (alarm 37) or error parameter No. 2301 will be output.

If an alarm occurs, the mechanical specifications and electrical specifications must be revised so that the electronic gears are within the specifications range.

ELG1 RNG1 x PC2 ELG2 = PIT x PC1 x IUNIT (Reduced fraction)

ELG1 PGN x RNG2 x PC2 ELG2 = 30 x RNG1 x PC1 (Reduced fraction)

IUNIT = 2/NC command unit (µm)

1µmIUNIT = 2, 0.1µm : IUNIT = 20

When the above is calculated, the following conditions must be satisfied.

ELG1 ≤ 32767

ELG2 ≤ 32767

·

Page 179 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 7.4.3 Lost Motion Compensation
Page 179 · click to enlarge
Page 179
7. Servo Parameters 7.4 Supplement

7.4.3 Lost Motion Compensation

When the motor is to rotate in the clockwise direction (looking from the load side) at the command for the + direction, the command direction is CW. Conversely, when the motor is to rotate in the counterclockwise direction, the command direction is CCW. This rotation direction can be set with the CNC machine parameters. Note that the meaning of the ± will differ for some servo parameters according to this motor rotation direction. The servo parameters affected by CW/CCW are shown below.

SV016 (LMC1), SV041 (LMC2) (When different values are set for SV016 and SV041) SV031 (OVS1), SV042 (OVS2) (When different values are set for SV031 and SV042) <Example> If the lost motion compensation amount is to be changed according to the direction,

the compensation amount at the quadrant changeover point of each arc where the lost motion compensation is applied will be as shown below according to the command polarity.

Mitsubishi Electronics CNC Controller Board (C64) — 7.4.3 Lost Motion Compensation diagram (page 179)
Fig. 47 · 7.4.3 Lost Motion Compensation

The Y axis command direction changes from the + to – direction.

The X axis command direction changes from the + to – direction.

The X axis command direction changes from the – to + direction.

The Y axis command direction changes from the – to + direction.

(Note) The setting value for the parameter is “0” or “-1”, the compensation amount is determined as

shown below.

Mitsubishi Electronics CNC Controller Board (C64) — 7.4.3 Lost Motion Compensation diagram (page 179)
Fig. 48 · 7.4.3 Lost Motion Compensation
Page 180 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8. Spindle Parameters 8.1 Spindle Base Specifications Parameters
Page 180 · click to enlarge
Page 180
8. Spindle Parameters 8.1 Spindle Base Specifications Parameters

8. Spindle Parameters 8.1 Spindle Base Specifications Parameters

For parameters indicated with a (PR) in the table, turn the NC power OFF after setting. The setting is validated after the power is turned ON again.

No. Items Details Setting range

Set spindle rotation speed for maximum motor rotation speed with gears 00, 01, 10, 11. (Set the spindle rotation speed for the S analog output 10V.)

0 to 99999 (r/min)

Set maximum spindle speed with gears 00, 01, 10, 11. Set the value that is equal to or larger than "slimit" value. By comparing the S command value of gear 1 to 4, a spindle gear shift command will be output automatically.

Set spindle rotation speed for gear shifting with gears 00, 01, 10, 11.

0 to 32767 (r/min)

(Note) Setting too large value may cause a gear

nicks when changing gears.

Set maximum spindle rotation speed during tap cycle with gears 00, 01, 10, 11.

0 to 99999 (r/min)

Set time constants for constant inclination synchronized tapping for gears 00, 01, 10, 11 (linear acceleration/deceleration pattern).

1 to 5000 (ms)

Show 11 more labels / short text on this page
(Unit) · slimit 1 · Limit rotation speed · smax 1 · Maximum rotation speed · ssift 1 · Shift rotation speed · stap 1 · Tap rotation speed · stapt 1 · Tap time constant
Page 181 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8. Spindle Parameters
Page 181 · click to enlarge
Page 181
8. Spindle Parameters 8.1 Spindle Base Specifications Parameters

Relationship between spindle limit rotation speed and maximum spindle rotation speed

Spindle rotation speed (r/min)

0 smax1 slimt1 smax2 slimt2 smax(n) slimt(n)

Limit rotation speed of gear 1 (Parameter setting)

Maximum rotation speed of gear 1 (Parameter setting)

Set "0" for any unused gears.

Relation between the spindle limit rotation speed and the spindle tap time constant (for the constant inclination synchronized tapping)

Spindle rotation speed (r/min) Spindle rotation speed (r/min)

Show 12 more labels / short text on this page
Output voltage (V) · slimt(n) · slimt(n) · slimt2 · slimt1 · S command · Time (ms) · Time (ms) · stapt1 0 · Execution time constant · stapt2 · stapt(n) stapt(n)
Page 182 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8. Spindle Parameters
Page 182 · click to enlarge
Page 182
8. Spindle Parameters 8.1 Spindle Base Specifications Parameters

# Items Details Setting range

3021 sori Orientation rotation speed

Set the spindle orientation rotation speed. Set the rotation speed for when the spindle rotates at the constant rotation speed.

0 to 32767 (r/min)

3022 sgear Encoder gear ratio

Set the gear ratio of the spindle to the encoder. 0: 1/1 1: 1/2 2: 1/4 3: 1/8

3023 smini Minimum rotation speed

Set the minimum rotation speed of the spindle. If an S command instructs the rotation speed below this setting, the spindle rotates at the minimum rotation speed set with this parameter.

0 to 32767 (r/min)

Set the type of the spindle to be connected.

0. No connection with the spindle 1: Serial connection (bus) 2 to 5: Analog output

3025 enc-on Spindle encoder

Set connection information of the spindle encoder.

0. No connection 1: Spindle connection (Spindle encoder connection check function valid.) 2: Serial connection of encoder

3026 cs_ori Selection of winding in orientation mode

0. Perform orientation using the winding selected when the orientation command is issued.
1. Use winding L whenever the orientation command is issued.

3027 cs_syn Selection of winding in spindle synchronou s mode

0. The winding H/L is selected by the actual spindle rotation speed (calculated from commanded rotation speed) when spindle synchronous control starts. (The winding is not switched during synchronous control. The control is carried out with the winding selected at start.) If the actual spindle rotation speed is less than SP020, the winding L is selected, and if more than the value, the winding H is selected. 1: Use winding H whenever the spindle synchronous command is issued.

3028 sprcmm L system tap cycle spindle forward run/ reverse run M command

Set the M code of the spindle forward run/reverse run command. High-order three digits :

The spindle forward run command's M code is set. Low-order three digits :

The spindle reverse run command's M code is set.

Show 4 more labels / short text on this page
(Unit) · sout Spindle connection · 0/1 · 0/1
Page 183 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8. Spindle Parameters
Page 183 · click to enlarge
Page 183
8. Spindle Parameters 8.1 Spindle Base Specifications Parameters

# Items Details Setting range

(Unit) 3037 3038 3039 3040

tapt 21 22 23 24

Synchronized tapping Switching spindle rota- tion speed 2

Set the spindle rotation speed at which the step-2 acceleration/deceleration time constant is to be switched at gear 00, 01, 10, or 11.

0 to 99999 (r/min)

3041 3042 3043 3044

tapt 21 22 23 24

Synchronized tapping Switching time constant 2

Set the time constant to reach Synchronized tapping switching spindle rotation speed 2 (#3037 to #3040) at gear 00, 01, 10, or 11.

1 to 5000 (ms)

3045 3046 3047 3048

tapt 31 32 33 34

Synchronized tapping Switching time constant 3

Set the time constant to reach the maximum rotation spindle speed (#3005 to #3008) at gear 00, 01, 10, or 11.

1 to 5000 (ms)

3049 spt Spindle synchroniza- tion acceleration/ deceleration time constant

Set the acceleration/deceleration time constant for when the spindle synchronization command's rotation speed changes during spindle synchronous control.

0 to 9999 (ms)

3050 sprlv Spindle synchroniza- tion rotation speed attainment level

The spindle rotation speed synchronization complete signal will turn ON when the difference of the reference spindle and synchronous spindle actual rotation speeds is less than the level set for the synchronous spindle rotation speed command value during spindle synchronous control.

0 to 4095 (pulse) (1 pulse = 0.088°)

3051 spplv Spindle phase synchroniza- tion attainment level

The spindle phase synchronization complete signal will turn ON when the phase difference of the reference spindle and synchronous spindle is less than the set level during spindle phase synchronization control.

0 to 4095 (pulse) (1 pulse = 0.088°)

3052 spplr Spindle motor spindle relative polarity

Set the spindle motor and spindle's relative polarity.

0. Positive polarity

Spindle CW rotation at motor CW rotation

1. Negative polarity

: Positive polarity Spindle CCW rotation at motor CW rotation

: Negative polarity

3053 sppst Spindle encoder Z -phase position

Set the deviation amount from the spindle's reference position to the spindle encoder's Z phase. The deviation amount is obtained using the clockwise direction looking from the front of the spindle as the positive direction.

Page 184 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8. Spindle Parameters
Page 184 · click to enlarge
Page 184
8. Spindle Parameters 8.1 Spindle Base Specifications Parameters

# Items Details Setting range

3054 sptc1 Spindle synchroniza- tion multi-step acceleration/ deceleration changeover speed 1

Set the spindle speed for changing the 1st step's acceleration/deceleration time constant.

0 to 99999 (r/min)

3055 sptc2 Spindle synchroniza- tion multi-step acceleration/ deceleration changeover speed 2

Set the spindle speed for changing the 2nd step's acceleration/deceleration time constant.

0 to 99999 (r/min)

3056 sptc3 Spindle synchroniza- tion multi-step acceleration/ deceleration changeover speed 3

Set the spindle speed for changing the 3rd step's acceleration/deceleration time constant.

0 to 99999 (r/min)

3057 sptc4 Spindle synchroniza- tion multi-step acceleration/ deceleration changeover speed 4

Set the spindle speed for changing the 4th step's acceleration/deceleration time constant.

0 to 99999 (r/min)

3058 sptc5 Spindle synchroniza- tion multi-step acceleration/ deceleration changeover speed 5

Set the spindle speed for changing the 5th step's acceleration/deceleration time constant.

0 to 99999 (r/min)

3059 sptc6 Spindle synchroniza- tion multi-step acceleration/ deceleration changeover speed 6

Set the spindle speed for changing the 6th step's acceleration/deceleration time constant.

0 to 99999 (r/min)

(Unit)

Page 185 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8. Spindle Parameters
Page 185 · click to enlarge
Page 185
8. Spindle Parameters 8.1 Spindle Base Specifications Parameters

# Items Details Setting range

3060 sptc7 Spindle synchroniza- tion multi-step acceleration/ deceleration changeover speed 7

Set the spindle speed for changing the 7th step's acceleration/deceleration time constant.

0 to 99999 (r/min)

3061 spdiv1 Magnification for time constant changeover speed 1

Set the acceleration/deceleration time constant between the spindle synchronization multi-step acceleration/deceleration changeover speed 1 (sptc1) to the spindle synchronization multi-step acceleration/deceleration changeover speed 2 (sptc2) as a magnification in respect to the spindle synchronization acceleration/deceleration time constant (spt).

3062 spdiv2 Magnification for time constant changeover speed 2

Set the acceleration/deceleration time constant between the spindle synchronization multi-step acceleration/deceleration changeover speed 2 (sptc2) to the spindle synchronization multi-step acceleration/deceleration changeover speed 3 (sptc3) as a magnification in respect to the spindle synchronization acceleration/deceleration time constant (spt).

3063 spdiv3 Magnification for time constant changeover speed 3

Set the acceleration/deceleration time constant between the spindle synchronization multi-step acceleration/deceleration changeover speed 3 (sptc3) to the spindle synchronization multi-step acceleration/deceleration changeover speed 4 (sptc4) as a magnification in respect to the spindle synchronization acceleration/deceleration time constant (spt).

3064 spdiv4 Magnification for time constant changeover speed 4

Set the acceleration/deceleration time constant between the spindle synchronization multi-step acceleration/deceleration changeover speed 4 (sptc4) to the spindle synchronization multi-step acceleration/deceleration changeover speed 5 (sptc5) as a magnification in respect to the spindle synchronization acceleration/deceleration time constant (spt).

3065 spdiv5 Magnification for time constant changeover speed 5

Set the acceleration/deceleration time constant between the spindle synchronization multi-step acceleration/deceleration changeover speed 5 (sptc5) to the spindle synchronization multi-step acceleration/deceleration changeover speed 6 (sptc6) as a magnification in respect to the spindle synchronization acceleration/deceleration time constant (spt).

(Unit)

Page 186 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8. Spindle Parameters
Page 186 · click to enlarge
Page 186
8. Spindle Parameters 8.1 Spindle Base Specifications Parameters

# Items Details Setting range

3066 spdiv6 Magnification for time constant changeover speed 6

Set the acceleration/deceleration time constant between the spindle synchronization multi-step acceleration/deceleration changeover speed 6 (sptc6) to the spindle synchronization multi-step acceleration/deceleration changeover speed 7 (sptc7) as a magnification in respect to the spindle synchronization acceleration/deceleration time constant (spt).

3067 spdiv7 Magnification for time constant changeover speed 7

Set the acceleration/deceleration time constant for the spindle synchronization multi-step acceleration/deceleration changeover speed 7 (sptc7) and higher as a magnification in respect to the spindle synchronization acceleration/deceleration time constant (spt).

3068 symtm1 Phase synchroniza- tion start confirmation time

Set the time to confirm that synchronization is attained before phase synchronization control is started. When "0" is set, the time will be 2 seconds. When "100" or less is set, the time will be 100ms.

0 to 9999 (ms)

3069 symtm2 Phase synchroniza- tion end confirmation time

Set the time to wait for phase synchronization control to end as the time for the rotation speed to reach the attainment range. When "0" is set, the time will be 2 seconds. When "100" or less is set, the time will be 100ms.

0 to 9999 (ms)

3070 syprt Phase synchroniza- tion speed

Set the fluctuation amount to change the synchronous spindle rotation speed during phase synchronization control as the command speed and rate. When "0" is set, the amount will be 100%.

(Not used.)

(Not used.)

(Unit)

Page 187 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — ! CAUTION
Page 187 · click to enlarge
Page 187
8. Spindle Parameters 8.2 MDS-B-SPJ2

8.2 MDS-B-SPJ2 For parameters marked with a (PR) in the tables, turn the NC power OFF after setting. The parameters will be valid after the power is turned ON again. The valid spindle parameters will differ according to the motor and amplifier type. Follow the correspondence table given below, and set the correct parameters. The spindle parameter setting and display method will differ according to the NC being used, so refer to Instruction Manual for each NC and the following spindles.

MELDAS AC Servo and Spindle MDS-A Series MDS-B Series Specifications Manual ...BNP-B3759

The "fixed control constants" and "fixed control bits" in this section are set by Mitsubishi.

! CAUTION

! Do not make remarkable adjustments or changes of the parameters as the operation may

become unstable.

! In the explanation on bits, set all bits not used, including blank bits, to “0”.

No. Items Details Setting

3201 SP001 PGM Magnetic detector and motor built- in encoder orientation- mode position loop gain

As the set value is larger, the orientation time becomes shorter and servo rigidity is increased. On the contrary, however, vibration is increased and the machine becomes likely to overshoot.

0 to 1000 (0.1 1/s)

3202 SP002 PGE Encoder orientation-mo de position loop gain

As the set value is larger, the orientation time becomes shorter and servo rigidity is increased. On the contrary, however, vibration is increased and the machine becomes likely to overshoot.

0 to 1000 (0.1 1/s)

SP003 Not used. Set to “0”. 0 0

3204 SP004 OINP Orientation in-position width

Set the position error range in which an orientation completion signal is output.

SP005 OSP Orientation mode changing speed limit value

Set the motor speed limit value to be used when the speed loop is changed to the position loop in orientation mode. When this parameter is set to "0", SP017 (TSP) becomes the limit value.

0 to 32767 (r/min)

3206 SP006 CSP Orientation mode dece- leration rate

As the set value is larger, the orientation time becomes shorter. On the contrary, however, the machine becomes likely to overshoot.

3207 SP007 OPST In-position

Set the stop position for orientation. Set the value by dividing 360° by 4096.

shift amount for orientation

SP008 Not used. Set to "0". 0 0

3209 SP009 PGT Synchronous tapping position loop gain

Set the spindle position loop gain in synchronous tapping mode.

1 to 100 (1/s)

Standard · range · setting

Page 188 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP011
Page 188 · click to enlarge
Page 188
8. Spindle Parameters 8.2 MDS-B-SPJ2

No. Items Details Setting

3210 SP010 PGS Spindle synchronous position loop gain

Set the spindle position loop gain in spindle synchronization mode.

1 to 100 (1/s)

SP011

Use not possible. 0 0

SP017 TSP Maximum motor speed

Set the maximum motor speed of the spindle.

1 to 32767 (r/min)

SP018 ZSP Motor zero speed

Set the motor speed for which zero-speed output is performed.

1 to 1000 (r/min)

SP019 CSN1 Speed cushion 1 Set the time constant for a speed

0 to 32767 (10ms)

command from "0" to the maximum speed. (This parameter is invalid in position loop mode.)

SP020 SDTS Speed detection set value

Set the motor speed so for which speed detection output is performed. Usually, the setting value is 10% of SP017 (TSP).

0 to 32767 (r/min)

SP021 TLM1 Torque limit 1 Set the torque limit rate for torque limit signal 001.

SP022 VGNP1 Speed loop gain

Set the speed loop proportional gain in speed control mode. When the gain is increased, response is improved but vibration and sound become larger.

0 to 1000 (1/s)

proportional term under speed control

SP023 VGNI1 Speed loop gain

Set the speed loop integral gain in speed control mode. Usually, set a value in proportion to SP022 (VGNP1).

0 to 1000 (0.1 1/s)

integral term under speed control

SP024 Not used. Set to "0". 0 0

SP025 GRA1 Spindle gear teeth count 1

Set the number of gear teeth of the spindle corresponding to gear 000.

SP026 GRA2 Spindle gear teeth count 2

Set the number of gear teeth of the spindle corresponding to gear 001.

SP027 GRA3 Spindle gear teeth count 3

Set the number of gear teeth of the spindle corresponding to gear 010.

SP028 GRA4 Spindle gear teeth count 4

Set the number of gear teeth of the spindle corresponding to gear 011.

SP029 GRB1 Motor shaft gear teeth count 1

Set the number of gear teeth of the motor shaft corresponding to gear 000.

SP030 GRB2 Motor shaft gear teeth count 2

Set the number of gear teeth of the motor shaft corresponding to gear 001.

SP031 GRB3 Motor shaft gear teeth count 3

Set the number of gear teeth of the motor shaft corresponding to gear 010.

SP032 GRB4 Motor shaft gear teeth count 4

Set the number of gear teeth of the motor shaft corresponding to gear 011.

Show 5 more labels / short text on this page
Standard · range · setting · to SP016 · (%)
Page 189 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.2 MDS-B-SPJ2
Page 189 · click to enlarge
Page 189
8. Spindle Parameters 8.2 MDS-B-SPJ2
Mitsubishi Electronics CNC Controller Board (C64) — 8.2 MDS-B-SPJ2 diagram (page 189)
Fig. 49

F E D C B A 9 8 poff hzs ront

7 6 5 4 3 2 1 0 sftk dflt 1a2m

bit Name Meaning when set to 0 Meaning when set to 1

0 1a2m 1 amplifier 2 motor function: Invalid 1 amplifier 2 motor function: Valid 1 dflt Default motor: Main Default motor: Sub 2 sftk SF-TK card invalid SF-TK card valid 3 4 5 6 7 8 9 A B C ront D E hzs F poff

7 6 5 4 3 2 1 0 mts1

bit Name Meaning when set to 0 Meaning when set to 1

Special motor constant setting valid 1 2 3 4 5 6 7 8 9 A B C D E F

(Note1) Always turn the bit2 at the same time to use

Page 190 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — F E D C B A 9 8
Page 190 · click to enlarge
Page 190
8. Spindle Parameters 8.2 MDS-B-SPJ2

No. Items Details Setting

SP035 SFNC3 Spindle function3

Set the spindle function 3 in bit units.

0000 to FFFF HEX setting

F E D C B A 9 8

7 6 5 4 3 2 1 0 hbsd hwid

(Note) Always set "0" for the empty bits.

bit Name Meaning when set to 0 Meaning when set to 1

H-coil wide-range constant output valid 1 2 hbsd H-coil base slide invalid H-coil base slide valid 3 4 5 6 7 8 9 A B C D E F

0 hwid H-coil wide-range constant output invalid

SP036 SFNC4 Spindle function 4

Set the spindle function 4 in bit units.

F E D C B A 9 8 dslm dssm

7 6 5 4 3 2 1 0 enc2 enc1 mag2 mag1 plg2 plg1 (Note) Always set "0" for the empty bits.

bit Name Meaning when set to 0 Meaning when set to 1 0 plg1 PLG of motor 1 valid PLG of motor 1 invalid 1 plg2 PLG of motor 2 valid PLG of motor 2 invalid 2 mag1 MAG of motor 1 valid MAG of motor 1 invalid 3 mag2 MAG of motor 2 valid MAG of motor 2 invalid 4 enc1 ENC of motor 1 valid ENC of motor 1 invalid 5 enc2 ENC of motor 2 valid ENC of motor 2 invalid 6 7 8 dssm Speedometer valid Speedometer invalid 9 dslm Load meter valid Load meter invalid A B C D E F

Standard · range · setting

Page 191 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.2 MDS-B-SPJ2
Page 191 · click to enlarge
Page 191
8. Spindle Parameters 8.2 MDS-B-SPJ2
Mitsubishi Electronics CNC Controller Board (C64) — 8.2 MDS-B-SPJ2 diagram (page 191)
Fig. 50

F E D C B A 9 8 nstv

7 6 5 4 3 2 1 0 plgo enco

bit Name Meaning when set to 0 Meaning when set to 1

Encoder orientation valid 1 2 plgo PLG orientation invalid PLG orientation valid 3 4 5 6 7

Monitoring only in position loop or orientation-mode 9 A B C D E F

F E D C B A 9 8 oplp

7 6 5 4 3 2 1 0 pftm alty

bit Name Meaning when set to 0 Meaning when set to 1

Thread cutting position data valid 3 4 5 6 7 8 9 A B C D E

Page 192 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.2 MDS-B-SPJ2
Page 192 · click to enlarge
Page 192
8. Spindle Parameters 8.2 MDS-B-SPJ2
Mitsubishi Electronics CNC Controller Board (C64) — 8.2 MDS-B-SPJ2 diagram (page 192)
Fig. 51

Set the amplifier type. Set each amplifier type or "0". This parameter corresponds to MDS-B-SPJ2.

SP040 MTYP Motor type 0000 to FFFF HEX setting

This is valid when SP034 (SFNC2) bit 0 is set to 0. Refer to the following standard motors, and set the applicable motor number.

Page 193 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP044 TRANS NC
Page 193 · click to enlarge
Page 193
8. Spindle Parameters 8.2 MDS-B-SPJ2

No. Items Details Setting

SP041 PTYP Power supply type

When this unit is a signal connection axis with power supply unit, set this parameter. Set "0" for this parameter for the unit which is not a signal connection axis.

0000 to FFFF HEX setting

Select a value from the following table according to the regenerative resistance being used.

(Note 1) This setting is used when using one

value (Ω)

(W)

0000 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 2A00 2B00 2C00

– Not connected FCUA-RB04 FCUA-RB075 FCUA-RB15 FCUA-RB22 FCUA-RB37 FCUA-RB55 FCUA-RB75/2 R–UNIT–1 R–UNIT–2 R–UNIT–3 R–UNIT–4 R–UNIT–5

– – 200 100 60 40 25 20 30/15 30 15 15 10 10

– – 60 80 120 155 185 340 340/680 700 700 2100 2100 3100

FCUA-RB75/2 and when using two in parallel.

SP042 Not used. Set to “0”. 0 0

SP043 Not used. Set to “0”. 0 0

SP044 TRANS NC

Set a frequency of data communication with NC.

0 to 32767 Standard0 Special: 1028

SP045 Not used. Set to “0”. 0 0

SP046 CSN2 Speed command dual cushion

For an acceleration/deceleration time constant defined in SP019 (CSN1) , this parameter is used to provide smooth movement only at the start of acceleration/deceleration. As the value of this parameter is smaller, it moves smoother but the acceleration/deceleration time becomes longer. To make this parameter invalid, set "0".

Set the reset hysteresis width for a speed detection set value defined in SP020 (SDTS).

0 to 1000 (r/min)

Show 11 more labels / short text on this page
Standard · range · setting · Setting · Regenerative resistance type · Resistance · Capacity · value · communi- cation frequency · SP047 SDTR Speed · detection reset value
Page 194 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP022
Page 194 · click to enlarge
Page 194
8. Spindle Parameters 8.2 MDS-B-SPJ2

No. Items Details Setting

SP048 SUT Speed reach range

Set the speed deviation rate with respect to the commanded speed for output of the speed reach signal.

3249 SP049 TLM2 Torque limit 2 Set the torque limit rate for the torque limit signal 010.

3250 SP050 TLM3 Torque limit 3 Set the torque limit rate for the torque limit signal 011.

3251 SP051 TLM4 Torque limit 4 Set the torque limit rate for the torque limit signal 100.

3252 SP052 TLM5 Torque limit 5 Set the torque limit rate for the torque limit signal 101.

3253 SP053 TLM6 Torque limit 6 Set the torque limit rate for the torque limit signal 110.

3254 SP054 TLM7 Torque limit 7 Set the torque limit rate for the torque limit signal 111.

Set the timer value until the excessive speed deviation alarm is output. The value of this parameter should be longer than the acceleration/deceleration time.

0 to 60 (s) 12

3256 SP056 PYVR Variable excitation (min value)

Set the minimum value of the variable excitation rate. Select a smaller value when gear noise is too high. However, a larger value is effective for impact response.

SP057 STOD Fixed control

Set by Mitsubishi. Set "0" unless designated in particular.

SP058

Not used. Set to "0". 0 0

SP063 OLT Overload alarm detection time

Set the time constant for detection of the motor overload alarm.

0 to 1000 (s)

SP064 OLL Overload alarm detection level

Set the detection level of the motor overload alarm.

SP065 VCGN1 Target value of

Set the magnification of speed loop proportional gain with respect to SP022 (VGNP1) at the maximum motor speed defined in SP017 (TSP).

variable speed loop proportional gain

Set the speed for starting change of speed loop proportional gain.

0 to 32767 (r/min)

starting speed of variable speed loop proportional gain

SP022

SP022× (SP065/100)

SP066 SP017

Show 10 more labels / short text on this page
Standard · range · setting · SP055 SETM Excessive · speed deviation timer · constant · to SP062 · SP066 VCSN1 Change · Proportional gain · Speed
Page 195 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.2 MDS-B-SPJ2
Page 195 · click to enlarge
Page 195
8. Spindle Parameters 8.2 MDS-B-SPJ2
Mitsubishi Electronics CNC Controller Board (C64) — 8.2 MDS-B-SPJ2 diagram (page 195)
Fig. 52

Set the speed for starting change of current loop gain.

Set the speed for ending change of current loop gain.

SP069 VIGN Target value of variable current loop gain

Set the magnification of current loop gain (torque component and excitation component) for a change ending speed defined in SP068 (VIGWB). When this parameter is set to "0", the magnification is 1.

0 to 6000 6001 to 8000 5000 8000 45 8001 or more 5000 10000 64

Set by Mitsubishi. Set "0" unless designated in particular.

Page 196 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.2 MDS-B-SPJ2
Page 196 · click to enlarge
Page 196
8. Spindle Parameters 8.2 MDS-B-SPJ2
Mitsubishi Electronics CNC Controller Board (C64) — 8.2 MDS-B-SPJ2 diagram (page 196)
Fig. 53

Set by Mitsubishi. Set "0" unless designated in particular.

Set the minimum value of variable torque limit at deceleration.

SP088 DIQN Speed for starting change of variable torque limit magnifica- tion at deceleration

Set the speed for starting change of torque limit value at deceleration.

Set by Mitsubishi. Set "0" unless designated in particular.

Set by Mitsubishi. Set "0" unless designated in particular.

Page 197 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.2 MDS-B-SPJ2
Page 197 · click to enlarge
Page 197
8. Spindle Parameters 8.2 MDS-B-SPJ2

No. Items Details Setting

SP096 EGAR Encoder gear

Set the gear ratio between the spindle end and the encoder end (except for the motor-built-in encoder) as indicated below.

0 1 : 1 1 1 : 1/2 2 1 : 1/4 3 1 : 1/8 4 1 : 1/16

–1 12 –2 1 : 4 –3 1 : 3

Set the orientation specifications in bit units.

0000 to FFFF HEX setting

F E D C B A 9 8 tlet

7 6 5 4 3 2 1 0 fdir pyfx dmin odi2 odi1

(Note) Always set "0" for the empty bits.

bit Name Meaning when set to 0 Meaning when set to 1 0 odi1

Orientation rotation direction 00: Previous (the direction in which the motor has so far rotated under speed control) 01: Forward rotation 10: Backward rotation 11: Prohibited (Same as setting value = 10)

2 dmin Dummy in-position invalid

3 pyfx Excitation min. (50%) during orientation servo lock invalid

Excitation min. (50%) during orientation servo lock valid 4

Encoder detector polarity: – 6 7 8 tlet Turret indexing invalid Turret indexing valid 9 A B C D E F

5 fdir Encoder detector polarity+

SP098 VGOP Speed loop

Set the speed loop proportional gain in orientation mode. When the gain is increased, rigidity is improved in the orientation stop but vibration and sound become larger.

0 to 1000 (1/s)

gain propor- tional term in orientation mode

SP099 VGOI Orientation mode speed loop gain integral term

Set the speed loop integral gain in orientation mode.

0 to 1000 (0.1 1/s)

Set the a loop gain delay advance gain in orientation mode. When this parameter is set to "0", PI control is exercised.

0 to 1000 (0.1 1/s)

mode speed loop gain delay advance term

Show 15 more labels / short text on this page
Standard · range · setting · ratio · Setting · Setting · Gear ratio (deceleration) · Gear ratio (Acceleration) · value · value · SP097 SPECO Orientation · specifica- tion · odi2 · Dummy in-position valid · SP100 VGOD Orientation
Page 198 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.2 MDS-B-SPJ2
Page 198 · click to enlarge
Page 198
8. Spindle Parameters 8.2 MDS-B-SPJ2

No. Items Details Setting

SP101 DINP Orientation advance in-position width

When using the orientation in-position advance function, set the in-position width that is larger than the normal in-position width defined in SP004 (OINP).

Set the excessive error width in orientation mode.

1 to 32767 (1/4 pulse) (1 pulse= 0.088°)

error value in orientation mode

SP103 FTM Index positioning completion OFF time timer

Set the time for forcedly turn OFF the index positioning completion signal (different from the orientation completion signal) after the leading edge of the indexing start signal.

1 to 10000 (ms)

SP104 TLOR Torque limit value for orientation servo locking

Set the torque limit value for orientation in-position output. If the external torque limit signal is input the torque limit value set by this parameter is made invalid.

SP105 IQG0 Current loop gain magnifica- tion 1 in orientation mode

Set the magnification for current loop gain (torque component) at orientation completion.

3306 SP106 IDG0 Current loop gain magnifica- tion 2 in orientation mode

Set the magnification for current loop gain (excitation component) at orientation completion.

3307 SP107 CSP2 Deceleration rate 2 in orientation mode

Set the deceleration rate in orientation mode corresponding to the gear 001. When this parameter is set to "0", same as SP006 (CSP).

3308 SP108 CSP3 Deceleration rate 3 in orientation mode

Set the deceleration rate in orientation mode corresponding to the gear 010. When this parameter is set to "0", same as SP006 (CSP).

SP109 CSP4 Deceleration rate 4 in orientation mode

Set the deceleration rate in orientation mode corresponding to the gear 011. When this parameter is set to "0", same as SP006 (CSP).

SP110 WCML Turret index

The integer magnification (gear ratio 1 : N) for the index position command (0 to 359) is set.

0 to 32767 (fold)

3311 SP111 WDEL Turret index deceleration magnifica- tion

The magnification for the orientation deceleration rate is set using 256 as 1.

0 to 32767 (1/256 -fold)

3312 SP112 WCLP Turret index clamp speed

The max. speed during indexing is set. This becomes the max. speed of the motor when set to "0".

0 to 32767 (r/min)

Show 5 more labels / short text on this page
Standard · range · setting · SP102 OODR Excessive · command magnifica- tion
Page 199 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP119
Page 199 · click to enlarge
Page 199
8. Spindle Parameters 8.2 MDS-B-SPJ2

No. Items Details Setting

SP113 WINP Turret index in-position width

The position error range is set in which an orientation (indexing) completed signal is output during turret indexing. This becomes the same as SP004 (OINP) when set to "0".

3314 SP114 OPER Orientation pulse miss check value

An alarm "5C" will occur if the pulse miss value in the orientation stop exceed this setting value. (Note that this is invalid when set to "0".) In this parameter, set the value to fulfill the following conditions. SP114 setting value > 1.5 × SP004 (orientation in-position width)

3315 SP115 OSP2 Orientation changeover speed limit value 2

When the door interlock spindle speed clamp signal is ON, this setting is used instead of OSP(SP005), CZRN(SP149) and TZRN(SP214). (Note that SP149 and SP214 are used only for the M65V.)

0 to 32767 (r/min)

SP116 OPYVR

Set by Mitsubishi. Set "0" unless designated in particular.

SP117 ORUT

3318 SP118 ORCT Number of orientation retry times

Set the number of times to retry when an orientation or feedback error occurs. The warning (A9) is issued while retrying orientation, and an alarm (5C) is issued when the set number of times is exceeded.

0 to 100 (time)

SP119

Not used. Set to “0”. 0 0

Show 5 more labels / short text on this page
Standard · range · setting · Fixed control constants · to SP176
Page 200 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — D
Page 200 · click to enlarge
Page 200
8. Spindle Parameters 8.2 MDS-B-SPJ2

No. Items Details Setting

Set the spindle synchronous specifications in bit units.

0000 to FFFF HEX setting

F E D C B A 9 8 odx8

7 6 5 4 3 2 1 0 fdir pyfx fclx

(Note) Always set "0" for the empty bits.

bit Name Meaning when set to 0 Meaning when set to 1 0 fclx Closed loop Semi-closed loop 1 2

3 pyfx Normal excitation Position loop excitation fixed (strong) 4

5 fdir Position detector polarity (+)

Position detector polarity (–) 6 7 8 9 A B C

Magnification of excessive error width × 8 times valid E F

odx8 Magnification of excessive error width × 8 times invalid

D

SP178 VGSP Spindle synchronous speed loop gain propor- tional term

Set the speed loop proportional gain in spindle synchronization mode.

0 to 1000 (1/s)

SP179 VGSI Spindle synchronous speed loop gain integral term

Set the speed loop integral gain in spindle synchronization mode.

0 to 1000 (0.1 1/s)

SP180 VGSD Spindle synchronous speed loop gain delay advance term

Set the speed loop delay advance gain in spindle synchronization mode. When this parameter is set to "0", PI control is exercised.

0 to 1000 (0.1 1/s)

SP181 VCGS Target value of variable speed loop proportional gain at spindle synchroniza-ti on

Set the magnification of speed loop proportional gain with respect to SP178 (VGSP) at the maximum speed defined in SP017 (TSP) at spindle synchronization.

Show 5 more labels / short text on this page
Standard · range · setting · SP177 SPECS Spindle · synchronous specifica- tions
Page 201 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP189
Page 201 · click to enlarge
Page 201
8. Spindle Parameters 8.2 MDS-B-SPJ2

No. Items Details Setting

SP182 VCSS Change starting speed of variable speed loop proportional gain at spindle synchroniza-ti on

Set the speed for starting change of speed loop proportional gain at spindle synchronization.

0 to 32767 (r/min)

SP178

SP178× (SP181/100)

SP182 SP017

3383 SP183 SYNV Sync match- ing speed at spindle syn- chronization

For changeover from the speed loop to the position loop at spindle synchronization, set a speed command error range for output of the sync speed matching signal.

0 to 1000 (r/min)

SP184 FFCS Acceleration rate feed forward gain at spindle synchronizati on

Set the acceleration rate feed forward gain at spindle synchronization. This parameter is used only with the SPJ2.

3385 SP185 SINP Spindle sync in-position width

Set the position error range for output of the in-position signal at spindle synchronization.

SP186 SODR Excessive error width at spindle synchronizati on

Set the excessive error width at spindle synchronization.

1 to 32767 (1/4 pulse) (1 pulse =0.088°)

SP187 IQGS Current loop gain magnifi- cation1 at spindle syn- chronization

Set the magnification of current loop gain (torque component) at spindle synchronization.

SP188 IDGS Current loop gain magnifi- cation 2 at spindle syn- chronization

Set the magnification of current loop gain (excitation component) at spindle synchronization.

SP189

Not used. Set to "0". 0 0

Show 6 more labels / short text on this page
Standard · range · setting · Proportional gain · Speed · to SP192
Page 202 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — E
Page 202 · click to enlarge
Page 202
8. Spindle Parameters 8.2 MDS-B-SPJ2

No. Items Details Setting

Set the synchronous tapping specifications in bit units.

0000 to FFFF HEX setting

F E D C B A 9 8 zrtn ptyp od8x

7 6 5 4 3 2 1 0 fdir cdir pyfx fclx

(Note) Always set "0" for the empty bits.

bit Name Meaning when set to 0 Meaning when set to 1 0 fclx Closed loop Semi-closed loop 1 2

3 pyfx Normal excitation Position loop excitation fixed (strong) 4 cdir Command polarity (+) Command polarity (–)

5 fdir Position detector polarity (+)

Position detector polarity (–) 6 7 8 9 A B C

od8x Magnification of excessive error width × 8 times invalid

Magnification of excessive error width × 8 times valid

D

ptyp Position control switch typeAfter zero point return
Position control switch typeAfter deceleration stop

E

F zrtn Zero point return direction: CCW

Zero point return directionCW

Set the speed loop proportional gain in synchronous tapping mode.

0 to 1000 (1/s)

tapping speed loop gain propor- tional term

Set the speed loop integral gain in synchronous tapping mode.

tapping speed loop gain integral term

(0.1 1/s)

Set the speed loop delay advance gain in synchronous tapping mode. When this parameter is set to "0", PI control is exercised.

tapping speed loop gain delay advance term

(0.1 1/s)

SP197 Not used. Set to "0". 0 0

SP198 VCGT Target value of

Set the magnification of speed loop proportional gain with respect to SP194 (VGTP) at the maximum motor speed defined in SP017 (TSP) at synchronous tapping.

variable speed loop proportional gain at synchronous tapping

Show 8 more labels / short text on this page
Standard · range · setting · SP193 SPECT Synchronous · tapping specifications · SP194 VGTP Synchronous · SP195 VGTI Synchronous · SP196 VGTD Synchronous
Page 203 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP204
Page 203 · click to enlarge
Page 203
8. Spindle Parameters 8.2 MDS-B-SPJ2

No. Items Details Setting

SP199 VCST Change starting

Set the speed for starting change of speed loop proportional gain at synchronous tapping.

0 to 32767 (r/min)

speed of variable speed loop proportional gain at synchronous tapping

SP194

SP199 SP017

Set the acceleration feed-forward gain for selection of gear 000 at synchronous tapping. This parameter should be used when an error of relative position to Z-axis servo is large.

tapping acceleration feed forward gain (gear 1)

Set the acceleration feed-forward gain for selection of gear 001 at synchronous tapping.

tapping acceleration feed forward gain (gear 2)

Set the acceleration feed-forward gain for selection of gear 010 at synchronous tapping.

tapping acceleration feed forward gain (gear 3)

Set the acceleration feed-forward gain for selection of gear 011 at synchronous tapping.

tapping acceleration feed forward gain (gear 4)

SP204

Not used. Set to "0". 0 0

3414 SP214 TZRN Synchronous tapping zero point return speed

This parameter is valid when SP193 (SPECT) bitE is set to "0". Set the zero point return speed used when the speed loop changes to the position loop.

0 to 500 (r/min)

3415 SP215 TPDT Synchronous tapping zero point return deceleration rate

This parameter is valid when SP193 (SPECT) bitE is set to "0". Set the deceleration rate where the machine starts to decelerate when it returns to the target stop point during synchronous tapping zero point return. When the machine tends to overshoot at the stop point set a smaller value.

1 to 10000 (pulse)

3416 SP216 TPST Synchronous tapping zero point return shift amount

This parameter is valid when SP193 (SPECT) bitE is set to "0". Set the synchronous tapping zero point position.

Show 10 more labels / short text on this page
Standard · range · setting · Proportional gain · SP194× (SP198/100) Speed · SP200 FFC1 Synchronous · SP201 FFC2 Synchronous · SP202 FFC3 Synchronous · SP203 FFC4 Synchronous · to SP213
Page 204 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.2 MDS-B-SPJ2
Page 204 · click to enlarge
Page 204
8. Spindle Parameters 8.2 MDS-B-SPJ2
Mitsubishi Electronics CNC Controller Board (C64) — 8.2 MDS-B-SPJ2 diagram (page 204)
Fig. 54

Set the position error range in which in-position signal is output during synchronize tapping.

SP219 IQGT Current loop gain magnifi- cation 1 at synchronous tapping

Set the magnification of current loop gain (torque component) during synchronous tapping.

SP220 IDGT Current loop gain magnifi- cation 2 at synchronous tapping

Set the magnification of current loop gain (excitation component) during synchronous tapping.

Set by Mitsubishi. Set "0" unless designated in particular.

Set the ratio of the motor inertia + load inertia and motor inertia. Setting

(Normally, set "100" or more. When less than "50" is set, the setting will be invalid.)

Page 205 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 3453 SP253
Page 205 · click to enlarge
Page 205
8. Spindle Parameters 8.2 MDS-B-SPJ2

No. Items Details Setting

SP234 OBS1 Disturbanc e observer low path filter frequency

Set the frequency of the low path filter for when the disturbance observer is valid.

0 to 1000 (1/s)

Setting (1/s) = 2πf

f: Approx. 1.5 times the disturbance

SP235 OBS2 Disturbanc e observer gain

Set the gain for the disturbance observer. 0 to 500 (%)

SP236

Not used. Set to "0". 0 0

3453 SP253

DA1NO D/A output channel 1 data number

Set the output data number for channel 1 of the D/A output function. When the setting value is "0", the output is speedometer. Refer to "8.5.1 D/A OUTPUT SPESIFICATIONS".

3454 SP254 DA2NO D/A output channel 2 data number

Set the output data number for channel 2 of the D/A output function. When the setting value is "0", the output is load meter. Refer to "8.5.1 D/A OUTPUT SPESIFICATIONS ".

3455 SP255 DA1MPY DA output channel 1 magnifica- tion

Set the data magnification for channel 1 of the D/A output function. The output magnification is (setting value)/256. When set to "0", the output magnification becomes 1-fold, in the same manner as when "256" is set. Refer to "8.5.1 D/A OUTPUT SPESIFICATIONS ".

–32768 to 32767 (1/256-fold)

3456 SP256 DA2MPY DA output channel 2 magnifica- tion

Set the data magnification for channel 2 of the D/A output function. The output magnification is (setting value)/256. When set to "0", the output magnification becomes 1-fold, in the same manner as when "256" is set. Refer to "8.5.1 D/A OUTPUT SPESIFICATIONS ".

–32768 to 32767 (1/256-fold)

Show 5 more labels / short text on this page
Standard · range · setting · frequency · to SP252
Page 206 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP321
Page 206 · click to enlarge
Page 206
8. Spindle Parameters 8.2 MDS-B-SPJ2

No. Items Details Setting

SP257

RPM BSD

Motor constant (H coil)

This parameter is valid only in the following two conditional cases: (a) In case that SP034 (SFNC2) bit0=1

0000 to FFFF HEX setting

and SP034 (SFNC2) bit2=0 Set the motor constants when using a special motor, not described in the SP040 (MTYP) explanation and when not using the coil changeover motor. (b) In case that SP034 (SFNC2) bit0=1

and SP034 (SFNC2) bit2=1 Set the motor constant of the H coil of the coil changeover motor. (Note) It is not allowed for the user to

change the setting.

SP321

RPML BSDL

Motor constant (L coil)

This parameter is valid only in the following conditional case: (a) In case that SP034 (SFNC2) bit0=1

0000 to FFFF HEX setting

and SP034 (SFNC2) bit2=1 Set the motor constant of the L coil of the coil changeover motor. (Note) It is not allowed for the user to

change the setting.

Show 7 more labels / short text on this page
Standard · range · setting · to SP320 · to 3520 (PR) · to SP384 · to 3584 (PR)
Page 207 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — ! CAUTION
Page 207 · click to enlarge
Page 207
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH The spindle parameter setting and display method will differ according to the NC being used, so refer to Instruction Manual for each NC and the following spindles.

MELDAS AC Servo and Spindle MDS-A Series MDS-B Series Specifications Manual .BNP-B3759 MELDAS AC Servo and Spindle MDS-C1 Series Specifications Manual BNP-C3000

For parameters marked with a (PR) in the tables, turn the NC power OFF after setting. The parameters will be valid after the power is turned ON again. The "fixed control constants" and "fixed control bits" in this section are set by Mitsubishi.

! CAUTION

! Do not make remarkable adjustments or changes of the parameters as the operation may

become unstable.

! In the explanation on bits, set all bits not used, including blank bits, to “0”.

No. Items Details Setting

3201 SP001 PGM Magnetic sensor and motor built-in encoder orientation position loop gain

As the set value is larger, the orientation time becomes shorter and servo rigidity is increased. However, vibration is increased and the machine becomes likely to overshoot.

0 to 1000 (0.1 1/s)

3202 SP002 PGE Encoder orientation position loop gain

As the set value is larger, the orientation time becomes shorter and servo rigidity is increased. However, vibration is increased and the machine becomes likely to overshoot.

0 to 1000 (0.1 1/s)

3203 SP003 PGC0 C-axis non-cutting position loop gain

Set the position loop gain in C-axis non-cutting mode. During non-cutting (rapid traverse, etc.) with the C axis control, this position loop gain setting is valid.

1 to 100 (1/s)

3204 SP004 OINP Orientation in-position width

Set the position error range in which an orientation completion signal is output.

SP005 OSP Orientation mode changing speed limit value

Set the motor speed limit value to be used when the speed loop is changed to the position loop in orientation mode. When this parameter is set to "0", SP017 (TSP) becomes the limit value.

0 to 32767 (r/min)

3206 SP006 CSP Orientation mode deceleration rate

As the set value is larger, the orientation time becomes shorter. However, the machine becomes likely to overshoot.

Standard · range · setting

Page 208 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP011
Page 208 · click to enlarge
Page 208
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

3207 SP007 OPST In-position shift amount for orientation

Set the stop position for orientation. (i)Motor built-in encoder, encoder:

(i) 0 to 4095

Set the value by dividing 360° by 4096. (ii)Magnetic sensor:

Divide –5° to +5° by 1024 and put 0° for 0.

SP008 Not used. Set to "0". 0 0

3209 SP009 PGT Synchroni- zed tapping Position loop gain

Set the spindle position loop gain in synchronized tapping mode.

1 to 100 (1/s)

3210 SP010 PGS Spindle synchro- nous position loop gain

Set the spindle position loop gain in spindle synchronization mode.

1 to 100 (1/s)

SP011

Use not possible. 0 0

SP017 TSP Maximum motor speed

Set the maximum motor speed of the spindle. 1 to 32767 (r/min)

SP018 ZSP Motor zero speed

Set the motor speed for which zero-speed output is performed.

1 to 1000 (r/min)

SP019 CSN1 Speed cushion 1

Set the time constant for a speed command from "0" to the maximum speed. (This parameter is invalid in position loop mode.)

1 to 32767 (10ms)

SP020 SDTS Speed detection set value

Set the motor speed so for which speed detection output is performed. Usually, the setting value is 10% of SP017 (TSP).

0 to 32767 (r/min)

3221 SP021 TLM1 Torque limit 1

Set the torque limit rate for torque limit signal 001. 0 to 120 (%) 10

Set the speed loop proportional gain in speed control mode. When the gain is increased, response is improved but vibration and sound become larger.

0 to 1000 (1/s)

loop gain propor- tional term under speed control

Set the speed loop integral gain in speed control mode. Usually, set a value in proportion to SP022 (VGNP1).

0 to 1000 (0.1 1/s)

loop gain integral term under speed control

Show 7 more labels / short text on this page
Standard · range · setting · (ii) –512 to · to SP016 · SP022 VGNP1 Speed · SP023 VGNI1 Speed
Page 209 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Page 209 · click to enlarge
Page 209
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

SP024 Use not possible. 0 0

SP025 GRA1 Spindle gear teeth count 1

Set the number of gear teeth of the spindle corresponding to gear 000.

SP026 GRA2 Spindle gear teeth count 2

Set the number of gear teeth of the spindle corresponding to gear 001.

SP027 GRA3 Spindle gear teeth count 3

Set the number of gear teeth of the spindle corresponding to gear 010.

SP028 GRA4 Spindle gear teeth count 4

Set the number of gear teeth of the spindle corresponding to gear 011.

SP029 GRB1 Motor shaft gear teeth count 1

Set the number of gear teeth of the motor shaft corresponding to gear 000.

SP030 GRB2 Motor shaft gear teeth count 2

Set the number of gear teeth of the motor shaft corresponding to gear 001.

SP031 GRB3 Motor shaft gear teeth count 3

Set the number of gear teeth of the motor shaft corresponding to gear 010.

SP032 GRB4 Motor shaft gear teeth count 4

Set the number of gear teeth of the motor shaft corresponding to gear 011.

Standard · range · setting

Page 210 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Page 210 · click to enlarge
Page 210
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

Set the spindle function 1 in bit units.

0000 to FFFF HEX setting

F E D C B A 9 8 poff hzs ront pycal pychg

7 6 5 4 3 2 1 0 pyst pyoff sftk dflt 1a2m (Note) Always set "0" for the empty bits.

bit Name Meaning when set to 0 Meaning when set to 1

0 1a2m 1 amplifier 2 motor function: Invalid 1 amplifier 2 motor function: Valid 1 dflt Default motor: Main Default motor: Sub 2 sftk SF-TK card invalid SF-TK card valid 3 4 5 6 pyoff 7 pyst 8 pychg

This is used by Mitsubishi. Set to "0" unless particularly designated.

9 pycal (Conventional specifications)

High-speed rate deceleration method valid for minimum excitation rate A

B This is used by Mitsubishi. Set to "0" unless particularly designated. C ront Normal ready ON High-speed ready ON

D This is used by Mitsubishi. Set to "0" unless particularly designated.

E hzs Gate OFF by high-cycle zero speed invalid

Gate OFF by high-cycle zero speed valid

F poff Contactor hold at NC power OFF invalid

Contactor hold at NC power OFF valid

(Note) When SPH is used, bit 0 and bit 1 will be invalid.

Show 5 more labels / short text on this page
Standard · range · setting · SP033 SFNC1 Spindle · function 1
Page 211 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — F E D C B A 9 8
Page 211 · click to enlarge
Page 211
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

Set the spindle function 2 in bit units.

0000 to FFFF HEX setting

F E D C B A 9 8

7 6 5 4 3 2 1 0 mkc2 mkch invm mts1 (Note) Always set "0" for the empty bits.

bit Name Meaning when set to 0 Meaning when set to 1

0 mts1 Special motor constant invalid

Special motor constant setting valid

1 invm A general-purpose motor FV control invalid

A general-purpose motor FV control valid

2 mkch Coil switch function invalid Coil switch function valid

3 mkc2 Coil switch specification 2 invalid Coil switch specification 2 valid (Note1) (Note2) 4 5 6 7 8 9 A B C D E F

(Note1) To validate bit3(mkc2), NC side needs to prepare. (Note2) Always turn the bit2 at the same time to use bit3.

Set the spindle function 3 in bit units.

0000 to FFFF HEX setting

F E D C B A 9 8

7 6 5 4 3 2 1 0 lbsd hbsd lwid hwid (Note) Always set "0" for the empty bits.

bit Name Meaning when set to 0 Meaning when set to 1

0 hwid H-coil wide-range constant output invalid

H-coil wide-range constant output valid

L-coil wide-range constant output valid 2 hbsd H-coil base slide invalid H-coil base slide valid 3 lbsd L-coil base slide invalid L-coil base slide valid 4 5 6 7 8 9 A B C D E F

1 lwid L-coil wide-range constant output invalid

(Used with SPJ.)

Show 7 more labels / short text on this page
Standard · range · setting · SP034 SFNC2 Spindle · function 2 · SP035 SFNC3 Spindle · function 3
Page 212 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Page 212 · click to enlarge
Page 212
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

Set the spindle function 4 in bit units.

0000 to FFFF HEX setting

F E D C B A 9 8 dslm dssm

7 6 5 4 3 2 1 0 enc2 enc1 mag2 mag1 plg2 plg1 (Note) Always set "0" for the empty bits.

bit Name Meaning when set to 0 Meaning when set to 1 0 plg1 PLG of motor 1 valid PLG of motor 1 invalid 1 plg2 PLG of motor 2 valid PLG of motor 2 invalid 2 mag1 MAG of motor 1 valid MAG of motor 1 invalid 3 mag2 MAG of motor 2 valid MAG of motor 2 invalid 4 enc1 ENC of motor 1 valid ENC of motor 1 invalid 5 enc2 ENC of motor 2 valid ENC of motor 2 invalid 6 7

8 dssm Speedometer output valid

9 dslm Load meter output valid Load meter output invalid A B C D E F

Set the spindle function 5 in bit units.

0000 to FFFF HEX setting

F E D C B A 9 8 splg dplg noplg nsno nosg

7 6 5 4 3 2 1 0 plgo mago enco (Note) Always set "0" for the empty bits.

bit Name Meaning when set to 0 Meaning when set to 1

0 enco Encoder orientation invalid

1 mago Magnetic sensor orientation invalid

Magnetic sensor orientation valid 2 plgo PLG orientation invalid PLG orientation valid 3 4 5 6 7

8 nosg No-signal detection type (Always monitoring)

Monitoring only in position loop or orientation-mode

9 nsno No-signal detection valid

Constant monitor of PLG-Z phase no-signal valid B C D E dplg F splg

Constant monitor of PLG-Z phase no-signal invalid

This is used by Mitsubishi. Set to "0" unless particularly designated.

(Note) For bit0 to 2, do not set two bits or more to

"1" at the same time.

Show 11 more labels / short text on this page
Standard · range · setting · SP036 SFNC4 Spindle · function 4 · Speedometer output invalid · SP037 SFNC5 Spindle · function 5 · Encoder orientation valid · No-signal detection invalid · A noplg
Page 213 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — B
Page 213 · click to enlarge
Page 213
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

Set the spindle function 6 in bit units.

0000 to FFFF HEX setting

F E D C B A 9 8 oplp lmx iqsv XFzs dcsn lmnp pl80 sdt2

7 6 5 4 3 2 1 0 vfbs orm adin tdn plg2 pftm alty

(Note) Always set "0" for the empty bits.

bit Name Meaning when set to 0 Meaning when set to 1

0 alty Deceleration stop during special alarm invalid

Deceleration stop during special alarm valid 1

2 pftm Encoder feedback serial communication invalid

Encoder feedback serial communication valid

3 plg2 Semi-closed pulse output signal×2 invalid

Semi-closed pulse output signal×2 valid 4

5 adin Interpolation during thread cutting invalid

Interpolation during thread cutting valid

6 orm Orientation start memo invalid

Orientation start memo valid

7 vfbs This is used by Mitsubishi. Set to "0" unless particularly designated.

8 sdt2 (Follows SFNC6-bitC setting)

Set output 2 to 2nd speed detection output

9 pl80 MHE90K detector's 180 wave PLG

180 wave PLG other than MHE90K

A lmnp This is used by Mitsubishi. Set to "0" unless particularly designated.

dcsn Dual cushion during acceleration/ deceleration valid

Dual cushion during acceleration/ deceleration invalid

B

C XFzs Set output 2 to MP scale low (L) speed mode

Set output 2 to zero speed output D iqsv E lmx

This is used by Mitsubishi. Set to "0" unless particularly designated

F oplp Open loop operation invalid

Open loop operation valid

bit Name Meaning when set to 0 Meaning when set to 1

0 alty Deceleration stop during special alarm invalid

Deceleration stop during special alarm valid 1

2 pftm Encoder feedback serial communication invalid

Encoder feedback serial communication valid

3 plg2 Semi-closed pulse output signal×2 invalid

Semi-closed pulse output signal×2 valid 4 tdn 5 adin Fixed control bit

6 orm Orientation start memo invalid

Orientation start memo valid 7 vfbs 8 sdt2 9 pl80 A lmnp B dcsn C XFzs D iqsv E lmx

F oplp Open loop operation invalid

Open loop operation valid

Show 8 more labels / short text on this page
Standard · range · setting · SP038 SFNC6 Spindle · function 6 · For MDS-C1-SP/SPH · For MDS-B-SP/SPH · Fixed control bit
Page 214 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Page 214 · click to enlarge
Page 214
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Mitsubishi Electronics CNC Controller Board (C64) — 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH diagram (page 214)
Fig. 55

Set the amplifier type. Set each amplifier type or "0"

Page 215 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Page 215 · click to enlarge
Page 215
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

SP040 MTYP Motor type This parameter is valid when SP034 (SFNC2) bit0 is set to "0". Set the appropriate motor number from the standard motors listed below.

0000 to FFFF HEX setting

setting Motor type Maximum

nding amplifier 0000 0001 SJ-2.2A 10000 r/min SP-22 0002 SJ-3.7A 10000 r/min SP-37 0003 SJ-5.5A 8000 r/min SP-55 0004 SJ-7.5A 8000 r/min SP-75 0005 SJ-11A 6000 r/min SP-110 0006 SJ-15A 6000 r/min SP-150 0007 SJ-18.5A 6000 r/min SP-185 0008 SJ-22A 4500 r/min SP-220 0009 SJ-26A 4500 r/min SP-260 000A SJ-30A 4500 r/min SP-300 000B 000C 000D 000E 000F 0010 0011 SJ-N0.75A 10000 r/min SP-075 0012 SJ-N1.5A 10000 r/min SP-15 0013 SJ-N2.2A 10000 r/min SP-22 0014 SJ-N3.7A 10000 r/min SP-37 0015 SJ-N5.5A 8000 r/min SP-55 0016 SJ-N7.5A 8000 r/min SP-75 0017 0018 0019 001A 001B SJ-J2.2A 10000 r/min SP-22 001C SJ-J3.7A 10000 r/min SP-37 001D SJ-J5.5A 8000 r/min SP-55 001E SJ-J7.5A 8000 r/min SP-75 001F

Show 6 more labels / short text on this page
Standard · range · setting · Corre-spo · Parameter · speed
Page 216 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Page 216 · click to enlarge
Page 216
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Mitsubishi Electronics CNC Controller Board (C64) — 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH diagram (page 216)
Fig. 56

F E D C B A 9 8 amp rtyp

7 6 5 4 3 2 1 0 ptyp bit Explanation 0 1

When the CN4 connector of the drive unit and the power supply are connected, setting below is necessary. To validate the external emergency stop function, add 40h.

3 Set- ting 0x 1x 2x 3x 4x 5x 6x 7x 8x

8 Set the regenerative resistor type when MDS-A-CR is used.

A 0 MDS-C1-CV (Setting when using power supply regeneration)

This parameter is used to set the C-axis detector range. Set "0" for this parameter. "2" is used by Mitsubishi for testing.

Page 217 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Page 217 · click to enlarge
Page 217
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

SP043 TRNG Synchro- nous tapping, spindle synchro- nous detector range

This parameter is used to set the synchronous tapping or spindle synchronous detector range. Set "0" for this parameter.

SP044 TRANS NC communi- cation frequency

Set a frequency of data communication with NC.

0 to 32767 Standard0 Special: 1028

3245 SP045 CSNT Dual cushion timer

Set the cycle to add the increment values in the dual cushion process. When this setting value is increased, the dual cushion will increase, and the changes in the speed during acceleration/deceleration will become gradual.

0 to 1000 (ms)

SP046 CSN2 Speed command dual cushion

For an acceleration/deceleration time constant defined in SP019 (CSN1) , this parameter is used to provide smooth movement only at the start of acceleration/deceleration. As the value of this parameter is smaller, it moves smoother but the acceleration/deceleration time becomes longer. To make this parameter invalid, set "0".

SP047 SDTR Speed detection reset value

Set the reset hysteresis width for a speed detection set value defined in SP020 (SDTS).

0 to 1000 (r/min)

SP047 SDTR Speed detection reset value

Set the reset hysteresis width for a speed detection set value defined in SP020 (SDTS).

0 to 1000 (r/min)

SP048 SUT Speed reach range

Set the speed deviation rate with respect to the commanded speed for output of the speed reach signal.

3249 SP049 TLM2 Torque limit 2

Set the torque limit rate for the torque limit signal 010.

3250 SP050 TLM3 Torque limit 3

Set the torque limit rate for the torque limit signal 011.

3251 SP051 TLM4 Torque limit 4

Set the torque limit rate for the torque limit signal 100.

3252 SP052 TLM5 Torque limit 5

Set the torque limit rate for the torque limit signal 101.

3253 SP053 TLM6 Torque limit 6

Set the torque limit rate for the torque limit signal 110.

3254 SP054 TLM7 Torque limit 7

Set the torque limit rate for the torque limit signal 111.

Standard · range · setting

Page 218 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Page 218 · click to enlarge
Page 218
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

SP055 SETM Excessive speed deviation timer

Set the timer value until the excessive speed deviation alarm is output. The value of this parameter should be longer than the acceleration/deceleration time.

0 to 60 (s) 12

3256 SP056 PYVR Variable excitation (min value)

Set the minimum value of the variable excitation rate. Select a smaller value when gear noise is too high. However, a larger value is effective for impact response.

SP057 STOD Constant → excessive judgment value

Set the value for judging when changing from a constant to excessive speed command.

0 to 50 (r/min)

SP058 SDT2 Fixed control constant

Set by Mitsubishi. Set "0" unless designated in particular.

SP059 MKT Winding changeover base shut-off timer

Set the base shut-off time for contactor switching at winding changeover. Note that the contactor may be damaged with burning if the value of this parameter is too small.

50 to 10000 (ms)

SP060 MKT2 Current limit timer after winding changeover

Set the current limit time to be taken after completion of contactor switching at winding changeover.

0 to 10000 (ms)

SP061 MKIL Current limit value after winding changeover

Set the current limit value during a period defined in SP060 (MKT2) after completion of contactor switching at winding changeover.

SP062 Not used. Set to "0". 0 0

Standard · range · setting

Page 219 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Page 219 · click to enlarge
Page 219
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Mitsubishi Electronics CNC Controller Board (C64) — 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH diagram (page 219)
Fig. 57

Set the time constant for detection of the motor overload alarm.

Set the detection level of the motor overload alarm.

Set the magnification of speed loop proportional gain with respect to SP022 (VGNP1) at the maximum motor speed defined in SP017 (TSP).

Set the speed when the speed loop proportional gain change starts.

Set the speed where the current loop gain change starts.

Set the speed where the current loop gain change ends.

SP069 VIGN Target value of variable current loop gain

Set the magnification of current loop gain (torque component and excitation component) for a change ending speed defined in SP068 (VIGWB). When this parameter is set to "0", the magnification is 1.

0 to 6000 6001 to 8000 5000 8000 45 8001 or more 5000 10000 64

Page 220 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP079 ILMT
Page 220 · click to enlarge
Page 220
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

3270 SP070 FHz Machine resonance suppressio n filter frequency

When machine vibration occurs in speed and position control, set the frequency of the required vibration suppression. Note that a value of 100Hz or more is set. Set to "0" when not used.

0 to 3000 (Hz)

SP071 VR2WA

Set by Mitsubishi. Set "0" unless designated in particular.

SP072 VR2WB

SP073 VR2GN

SP074 IGDEC

3275 SP075 R2KWS

F E D C B A 9 8 r2ini 7 6 5 4 3 2 1 0 r2am r2lm r2dn no51 r2ch bit Name Meaning when set to 0 Meaning when set to 1 0 r2ch 1 no51 2 r2dm 3 r2lm 4 r2am

This is used by Mitsubishi. Set to "0" unless particularly designated.

5 6 7 8 r2ini This is used by Mitsubishi. Set to "0" unless particularly designated 9 A B C D E F

3276 SP076 FONS Machine resonance suppressio n filter operation speed

When the vibration increases in motor stop (ex. in orientation stop) when the machine vibration suppression filter is operated by SP070, operate the machine vibration suppression filter at a speed of this parameter or more. When set to "0", this is validated for all speeds.

0 to 32767 (r/min)

SP077 TDSL Fixed control constant

Set by Mitsubishi. Set "14" unless designated in particular.

SP078 FPWM

Set by Mitsubishi. Set "0" unless designated in particular.

SP079 ILMT

Show 5 more labels / short text on this page
Standard · range · setting · Fixed control constant · Fixed control constant
Page 221 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP087
Page 221 · click to enlarge
Page 221
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

SP080 Use not possible. 0 0

SP081 LMCA

This is used by Mitsubishi. Set to "0" unless particularly designated.

SP082 LMCB

SP083

SP084

Use not possible. 0 0

SP087 DIQM Target value of

Set the minimum value of variable torque limit at deceleration.

variable torque limit magnifica- tion at deceleration

SP088 DIQN Speed for starting change of variable torque limit magnifica- tion at deceleration

Set the speed where the torque limit value at deceleration starts to change.

0 to 32767 (r/min)

Inversely proportional to speed

SP087

SP088 SP017

SP089 Use not possible. 0 0

SP090 Use not possible. 0 0

3291 SP091 OFSN Motor PLG forward rotation offset compensa- tion

Set the PLG offset value for the forward rotation. Normally set to "0".

–2048 to 2047 (–1mv)

3292 SP092 OFSI Motor PLG reverse rotation offset compensa- tion

Set the PLG offset value for the reverse rotation. Normally set to "0".

–2048 to 2047 (–1mv)

SP093 ORE Tolerable pulse check error

Set this when detecting the pulse detector's pulse mistakes. (Valid only for full close control.)

SP094 LMAV Load meter

Set the filter time constant of load meter output. When "0" is set, a filter time constant is set to 100ms.

0 to 32767 (2ms)

SP095 VFAV Fixed control

Set by Mitsubishi. Set "0" unless designated in particular.

Show 9 more labels / short text on this page
Standard · range · setting · Fixed control constant · to SP086 · Torque limit · 100% · output filter · constant
Page 222 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Page 222 · click to enlarge
Page 222
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

SP096 EGAR Encoder gear ratio

Set the gear ratio between the spindle end and the encoder end (except for the motor-built-in encoder) as indicated below.

0 1 : 1 1 1 : 1/2 2 1 : 1/4 3 1 : 1/8 4 1 : 1/16

–1 12 –2 1 : 4 –3 1 : 3

Set the orientation specifications in bit units.

0000 to FFFF HEX setting

F E D C B A 9 8 ostp orze ksft gchg ips2 zdir

7 6 5 4 3 2 1 0 vg8x mdir fdir osc1 pyfx dmin odi2 odi1

(Note) Always set "0" for the empty bits.

bit Name Meaning when set to 0 Meaning when set to 1 0 odi1

Orientation rotation direction 00: Previous (the direction in which the motor has so far rotated under speed control) 01: Forward rotation 10: Backward rotation 11: Prohibited (Same as setting value = 10)

2 dmin Orientation in-position advance invalid

Orientation in-position advance valid

3 pyfx Excitation min. (50%) during orientation servo lock invalid

Excitation min. (50%) during orientation servo lock valid

4 osc1 Indexing speed clamp invalid

Indexing speed clamp valid

5 fdir Encoder detector polarity+
Encoder detector polarity–
6 mdir Magnetic sensor polarity+
Magnetic sensor polarity–

7 vg8x Speed gain *1/8 during torque limit valid

Speed gain *1/8 during torque limit invalid 8

9 zdir This is used by Mitsubishi. Set to "0" unless particularly designated. A ips2 2nd in-position invalid 2nd in-position valid B

C gchg Gain changeover during orientation invalid

Gain changeover during orientation valid

D ksft Orientation virtual target shift invalid

Orientation virtual target shift valid E orze F ostp

This is used by Mitsubishi. Set to "0" unless particularly designated.

In-position advance (bit 2)

0 (invalid) 1 (valid)

In-position signal in OINP width=1 Control output 4/ bit 4=1 Second in-position signal=0 Control output 4/ bit F=1

In-position signal in OINP width=1 Control output 4/ bit 4=1 Second in-position signal=0 Control output 4/ bit F=0

In-position signal in DINP width=1 Control output 4/ bit 4=1 Second in-position signal in OINP width = 0 Control output 4/ bit F=1

Show 15 more labels / short text on this page
Standard · range · setting · Setting · Setting · Gear ratio (deceleration) · Gear ratio (acceleration) · value · value · SP097 SPECO Orientation · specifica- tion · odi2 · 0 (Invalid) · Second in-position · 1 (Valid)
Page 223 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Page 223 · click to enlarge
Page 223
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

SP098 VGOP Speed loop gain propor- tional term in orientation mode

Set the speed loop proportional gain in orientation mode. When the gain is increased, rigidity is improved in the orientation stop but vibration and sound become larger.

0 to 1000 (1/s)

SP099 VGOI Orientation mode speed loop gain integral term

Set the speed loop integral gain in orientation mode.

0 to 1000 (0.1 1/s)

SP100 VGOD Orientation mode speed loop gain delay advance term

Set a loop gain delay advance gain in orientation mode. When this parameter is set to "0", PI control is applied.

0 to 1000 (0.1 1/s)

SP101 DINP Orientation advance in-position width

When using the orientation in-position advance function, set the in-position width that is larger than the normal in-position width defined in SP004 (OINP).

SP102 OODR Excessive error value in orientation mode

Set the excessive error width in orientation mode.

0 to 32767 (1/4 pulse) (1 pulse= 0.088°)

SP103 FTM Index positioning completion OFF time timer

Set the time for forcedly turn OFF the index positioning completion signal (different from the orientation completion signal) after the leading edge of the indexing start signal.

0 to 10000 (ms)

SP104 TLOR Torque limit value for orientation servo locking

Set the torque limit value for orientation in-position output. If the external torque limit signal is input, the torque limit value set by this parameter is made invalid.

SP105 IQG0 Current loop gain magnifica- tion 1 in orientation mode

Set the magnification for current loop gain (torque component) at orientation completion.

SP106 IDG0 Current loop gain magnifica- tion 2 in orientation mode

Set the magnification for current loop gain (excitation component) at orientation completion.

3307 SP107 CSP2 Deceleration rate 2 in orientation mode

Set the deceleration rate in orientation mode corresponding to the gear 001. When this parameter is set to "0", same as SP006 (CSP).

Standard · range · setting

Page 224 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP110
Page 224 · click to enlarge
Page 224
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

3308 SP108 CSP3 Deceleration rate 3 in orientation mode

Set the deceleration rate in orientation mode corresponding to the gear 010. When this parameter is set to "0", same as SP006 (CSP).

3309 SP109 CSP4 Deceleration rate 4 in orientation mode

Set the deceleration rate in orientation mode corresponding to the gear 011. When this parameter is set to "0", same as SP006 (CSP).

SP110

Use not possible. 0

3314 SP114 OPER Orientation pulse miss check value

An alarm "5C" will occur if the pulse miss value at the orientation stop exceeds this setting value. (Note that this is invalid when set to "0".) In this parameter, set the value to fulfill the following conditions. SP114 setting value > 1.5 × SP004 (orientation in-position width)

3315 SP115 OSP2 Orientation motor speed clamp value 2

When the orientation clamp speed is changed by the control input, this parameter setting will be used instead of SP005: OSP. Indexing speed clamp valid This parameter is used when (SP097: SPEC0-bit4 = 1).

0 to 32767 (r/min)

3316 SP116 OPYVR Minimum excitation value after changeover (2nd minimum excitation rate)

Minimum excitation rate when position control input or external input is selected.

3317 SP117 ORUT This is used by Mitsubishi. Set to "0" unless particularly designated.

3318 SP118 ORCT Number of orientation retry times

Set the number of times to retry when an orientation or feedback error occurs. The warning (A9) is issued while retrying orientation, and an alarm (5C) is issued when the set number of times is exceeded.

0 to 100 (time)

3319 SP119 MPGH Orientation position gain H winding compensa- tion magnifi- cation

Set the compensation magnification of the orientation position loop gain for the H winding. H winding orientation position loop gain = SP001 (or SP002) × SP119/256 When set to "0", will become the same as SP001 or SP002.

0 to 2560 (1/256-fold)

Show 4 more labels / short text on this page
Standard · range · setting · to SP113
Page 225 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Page 225 · click to enlarge
Page 225
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

3320 SP120 MPGL Orientation position gain L winding compensa- tion magnifi- cation

Set the compensation magnification of the orientation position loop gain for the L winding. L winding orientation position loop gain = SP001 (or SP002) × SP120/256 When set to "0", will become the same as SP001 or SP002.

0 to 2560 (1/256-fold)

3321 SP121 MPCSH Orientation deceleration rate H winding compensa- tion magnifi- cation

Set the compensation magnification of the orientation deceleration rate for the H winding. Orientation deceleration rate for the H winding = SP006 × SP121/256 When set to "0", will become the same as SP006.

0 to 2560 (1/256-fold)

3322 SP122 MPCSL Orientation deceleration rate L winding compensa- tion magnifi- cation

Set the compensation magnification of the orientation deceleration rate for the L winding. Orientation deceleration rate for the L winding = SP006 × SP122/256 When set to "0", will become the same as SP006.

0 to 2560 (1/256-fold)

3323 SP123 MGD0 Magnetic sensor output peak value

This parameter is used for adjustment of orientation operation of the magnetic sensor. Set the output peak value of the magnetic sensor. If a gap between the sensor and the magnetizing element is small, increase the value of this parameter. If it is large, decrease the value of this parameter.

1 to 10000 Standard magnetizin g element: 542 Small magnetizin g element: 500

3324 SP124 MGD1 Magnetic sensor linear zone width

This parameter is used for adjustment of orientation operation of the magnetic sensor. Set the linear zone width of the magnetic sensor. If the radius of the mounted magnetizing element is large, decrease the value of this parameter. If it is small, increase the value of this parameter.

1 to 10000 Standard magnetizin g element: 768 Small magnetizin g element: 440

Standard · range · setting

Page 226 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — E
Page 226 · click to enlarge
Page 226
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

3325 SP125 MGD2 Magnetic sensor switching point

This parameter is used for adjustment of orientation operation of the magnetic sensor. Set the distance dimension from the target stop point at switching from position feedback to magnetic sensor output. Normally, set a value that is approx. 1/2 of the value defined in SP124.

1 to 10000 Standard magnetizin g element: 384 Small magnetizin g element: 220

SP126

Use not possible. 0 0

Set the C-axis specifications in bit units.

F E D C B A 9 8 zrtn ptyp fb9x zrtd zrn2 zdir ztyp

7 6 5 4 3 2 1 0 vg8x fdir phos rtrn adin fclx

(Note) Always set "0" for the empty bits.

bit Name Meaning when set to 0 Meaning when set to 1

0 fclx Closed loop Semi-closed loop (Gear 1 : 1 only)

1 adin Interpolation A/D compensation invalid

Interpolation A/D compensation valid

2 rtrn Position monitor during ready OFF invalid

Position monitor during ready OFF valid

3 phos Normal (no compensation)

Vx4 synchronization compensation valid 4

5 fdir Position detector polarity (+)

Position detector polarity (–) 6

7 vg8x Speed gain × 1/8 during torque limit valid

Speed gain × 1/8 during torque limit invalid

8 ztyp Z-phase typeNormal start up Z-phase type: Start up only

9 zdir Z-phase rising polarity (+) Z-phase rising polarity (–)

A B zrn2 C zrtd

This is used by Mitsubishi. Set to "0" unless particularly designated.

D fb9x Speed feedback Standard (PLG)

Speed feedback 90,000 pulse detector

ptyp Position control switch typeAfter zero point return

E

Position control switch typeAfter deceleration stop

F zrtn Zero point return direction: CCW

Zero point return directionCW

3330 SP130 PGC1 First position loop gain for cutting on C-axis

Set the position loop gain when the first gain is selected for C axis cutting.

1 to 100 (1/s)

3331 SP131 PGC2 Second position loop gain for cutting on C-axis

Set the position loop gain when the second gain is selected for C axis cutting.

1 to 100 (1/s)

Show 6 more labels / short text on this page
Standard · range · setting · to SP128 · SP129 SPECC C-axis · specifica- tions
Page 227 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Page 227 · click to enlarge
Page 227
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

3332 SP132 PGC3 Third position loop gain for cutting on C-axis

Set the position loop gain when the third gain is selected for C-axis cutting.

1 to 100 (1/s)

3333 SP133 PGC4 Stop position loop gain for cutting on C-axis

Set the position loop gain for stopping when carrying out C-axis cutting.

1 to 100 (1/s)

Set the speed loop proportional gain in C-axis non-cutting mode.

0 to 5000 (1/s)

non-cutting speed loop gain proportional item

SP135 VGCI0 C-axis non-cutting speed loop gain integral item

Set the speed loop integral gain in C-axis non-cutting mode.

0 to 5000 (0.1 1/s)

Set the speed loop delay advance gain in C-axis non-cutting mode. When this parameter is set to "0", PI control is exercised.

0 to 5000 (0.1 1/s)

non-cutting speed loop gain delay advance item

SP137 VGCP1 First speed

Set the speed loop proportional gain when the first gain is selected for C-axis cutting.

0 to 5000 (1/s)

loop gain proportional item for C-axis cutting

SP138 VGCI1 First speed loop gain integral item for cutting on C-axis

Set the speed loop integral gain when the first gain is selected for C-axis cutting.

0 to 5000 (0.1 1/s)

SP139 VGCD1 First speed

Set the speed loop delay advance gain when the first gain is selected for curing on the C-axis. When this parameter is set to "0", PI control is applied.

0 to 5000 (0.1 1/s)

loop gain delay advance item for cutting on C-axis

Set the speed loop proportional gain when the second gain is selected for C-axis cutting.

0 to 5000 (1/s)

speed loop gain proportional item for cutting on C-axis

Show 6 more labels / short text on this page
Standard · range · setting · SP134 VGCP0 C-axis · SP136 VGCD0 C-axis · SP140 VGCP2 Second
Page 228 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Page 228 · click to enlarge
Page 228
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

SP141 VGCI2 Second speed loop gain integral item for cutting on C-axis

Set the speed loop integral gain when the second gain is selected for C-axis cutting.

0 to 5000 (0.1 1/s)

SP142 VGCD2 Second speed loop gain delay advance item for cutting on C-axis

Set the speed loop delay advance gain when the second gain is selected for C-axis cutting. When this parameter is set to "0", PI control is applied.

0 to 5000 (0.1 1/s)

SP143 VGCP3 Third speed loop gain proportional item for cutting on C-axis

Set the speed loop proportional gain when the third gain is selected for C-axis cutting.

0 to 5000 (1/s)

SP144 VGCI3 Third speed loop gain integral item for cutting on C-axis

Set the speed loop integral gain when the third gain is selected for C-axis cutting.

0 to 5000 (0.1 1/s)

SP145 VGCD3 Third speed loop gain delay advance item for cutting on C-axis

Set the speed loop delay advance gain when the third gain is selected for C-axis cutting. When this parameter is set to "0", PI control is applied.

0 to 5000 (0.1 1/s)

SP146 VGCP4 Speed loop gain propor- tional item for stop of cutting on C-axis

Set the speed loop proportional gain when C-axis cutting is stopped.

0 to 5000 (1/s)

SP147 VGCI4 Speed loop gain integral item for stop of cutting on C-axis

Set the speed loop integral gain when C-axis cutting is stopped.

0 to 5000 (0.1 1/s)

SP148 VGCD4 Speed loop gain delay advance item for stop of cutting on C-axis

Set the speed loop delay advance gain when C-axis cutting is stopped. When this parameter is set to "0", PI control is applied.

0 to 5000 (0.1 1/s)

Standard · range · setting

Page 229 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP157
Page 229 · click to enlarge
Page 229
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

3349 SP149 CZRN C-axis zero point return speed

This parameter is valid when SP129 (SPECC) bitE is set to "0". Set the zero point return speed used when the speed loop changes to the position loop.

1 to 500 (r/min)

3350 SP150 CPDT C-axis zero point return deceleration point

This parameter is valid when SP129 (SPECC) bitE is set to "0". Set the deceleration rate where the machine starts to decelerate when it returns to the target stop point during C-axis zero point return. When the machine tends to overshoot at the stop point, set the smaller value.

3351 SP151 CPSTL C-axis zero point return shift amount (low byte)

This parameter is valid when SPECC (SP129) bitE is set to "0". Set the C-axis zero point position.

HEX setting 00000000 to FFFFFFFF (1/1000°)

H: 0000 L: 0000

3352 SP152 CPSTH C-axis zero point return shift amount (high byte)

Set the excessive error width on the C-axis. HEX setting

H: 0001 L: D4C0

error width on C-axis (low byte)

00000000 to FFFFFFFF (1/1000°)

error width on C-axis (high byte)

3356 SP156 OVSH C-axis overshoot compensa- tion

Set this to prevent overshooting when shifting from movement to stopping with C-axis control. (Set this referring to the load meter display when overshooting occurred.)

SP157

Not used. Set to "0". 0 0

3359 SP159 CPY0 C-axis non-cutting variable excitation ratio

Set the minimum value of variable excitation ratio for non-cutting on the C-axis .

3360 SP160 CPY1 C-axis cutting variable excitation ratio

Set the minimum variable excitation ratio for cutting on the C-axis.

Show 6 more labels / short text on this page
Standard · range · setting · SP154 CODRL Excessive · SP155 CODRH Excessive · to SP158
Page 230 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP169
Page 230 · click to enlarge
Page 230
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

SP161 IQGC0 Current loop

Set the magnification of current loop gain (torque component) for C-axis non-cutting.

gain magnifi- cation 1 for non-cutting on C-axis

SP162 IDGC0 Current loop gain magnifi- cation 2 for non-cutting on C-axis

Set the magnification of current loop gain (excitation component) for C-axis non-cutting.

SP163 IQGC1 Current loop

Set the magnification of current loop gain (torque component) for C-axis cutting.

gain magnifi- cation 1 for cutting on C-axis

SP164 IDGC1 Current loop gain magnifi- cation 2 for cutting on C-axis

Set the magnification of current loop gain (excitation component) for C-axis cutting.

3365 SP165 PG2C C-axis position loop gain 2

Set the second position loop gain when high-gain control is carried out for control of the C-axis. This parameter is applied to all the operation modes of C-axis control. When this function is not used, assign "0".

0 to 999 (1/s)

3366 SP166 PG3C C-axis position loop gain 3

Set the third position loop gain when high-gain control is carried out for control of the C-axis. This parameter is applied to all the operation modes of C-axis control. When this function is not used, assign "0".

0 to 999 (1/s)

SP167

PGU Position loop gain for increased spindle holding force

Set the position loop gain for when the disturbance observer is valid.

0 to 100 (1/s)

SP168

VGUP Speed loop gain proportional item for increased spindle holding force

Set the speed loop gain proportional item for when the disturbance observer is valid.

0 to 5000 (1/s)

SP169

VGUI Speed loop gain integral item for increased spindle holding force

Set the speed loop gain integral item for when the disturbance observer is valid.

0 to 5000 (0.1 1/s)

Standard · range · setting

Page 231 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Page 231 · click to enlarge
Page 231
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Mitsubishi Electronics CNC Controller Board (C64) — 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH diagram (page 231)
Fig. 58

VGUD Speed loop gain delay advance item for increased spindle holding force

Set the speed loop gain delay advance item for when the disturbance observer is valid.

F E D C B A 9 8 Odx8 phos

7 6 5 4 3 2 1 0 fdir pyfx rtrn adin fclx

bit Name Meaning when set to 0 Meaning when set to 1 0 fclx Closed loop Semi-closed loop

3 pyfx Normal excitation Position loop excitation fixed (strong) 4

Position detector direc- tion (negative direction) 6 7 8 9 A B C

Magnification of excessive error width × 8 times valid E F (Used with SPJ)

odx8 Magnification of excessive error width × 8 times invalid

SP178 VGSP Spindle synchronous speed loop gain propor- tional term

Set the speed loop proportional gain in spindle synchronous mode.

SP179 VGSI Spindle synchronous speed loop gain integral term

Set the speed loop integral gain in spindle synchronous mode.

Page 232 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP178
Page 232 · click to enlarge
Page 232
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

SP180 VGSD Spindle synchronous speed loop gain delay advance term

Set the speed loop delay advance gain in spindle synchronous mode. When this parameter is set to "0", PI control is applied.

0 to 1000 (0.1 1/s)

SP181 VCGS Spindle synchronous Target value of variable speed loop proportional gain

Set the magnification of speed loop proportional gain with respect to SP178 (VGSP) at the maximum speed defined in SP017 (TSP) in spindle synchronous mode.

SP182 VCSS Spindle synchronous Change starting speed of variable speed loop proportional gain

Set the speed when the speed loop proportional gain change starts in the spindle synchronous mode.

0 to 32767 (r/min)

SP178

SP178× (SP181/100)

SP182 SP017

3383 SP183 SYNV Spindle synchronous Sync match- ing speed

For changeover from the speed loop to the position loop in the spindle synchronous mode, set a speed command error range for output of the synchronous speed matching signal.

0 to 1000 (r/min)

SP184 FFCS Spindle synchronous Acceleration rate feed forward gain

Set the acceleration rate feed forward gain in the spindle synchronous mode. This parameter is used only with the SPJ2.

3385 SP185 SINP Spindle synchronous In-position width

Set the position error range for output of the in-position signal in the spindle synchronous mode.

SP186 SODR Spindle synchronous Excessive error width

Set the excessive error width in the spindle synchronous mode.

1 to 32767 ( pulse) (1 pulse =0.088°)

SP187 IQGS Spindle synchronous Current loop gain magnifi- cation1

Set the magnification of current loop gain (torque component) in the spindle synchronous mode.

Show 5 more labels / short text on this page
Standard · range · setting · Proportional gain · Speed
Page 233 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — E
Page 233 · click to enlarge
Page 233
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

SP188 IDGS Spindle synchronous Current loop gain magnifi- cation 2

Set the magnification of current loop gain (excitation component) in the spindle synchronous mode.

3389 SP189 PG2S Spindle synchronous Position loop gain 2

Set the second position loop gain when high-gain control is carried out in the spindle synchronous mode. When this parameter function is not used, set to "0".

0 to 999 (1/s)

3390 SP190 PG3S Spindle synchronous Position loop gain 3

Set the third position loop gain when high-gain control is carried out in the spindle synchronous mode. When this parameter function is not used, set to "0".

0 to 999 (1/s)

SP191 Use not possible. 0 0

SP192 Not used. Set to "0".

Set the synchronized tapping specifications in bit units.

0000 to FFFF HEX setting

F E D C B A 9 8 zrtn ptyp od8x phos

7 6 5 4 3 2 1 0 fdir cdir pyfx adin fclx

bit Name Meaning when set to 0 Meaning when set to 1

0 fclx Closed loop Semi-closed loop (Gear 1 : 1 only)

1 adin Interpolation A/D compensation invalid

Interpolation A/D compensation valid

2 rtrn Position monitor during ready OFF invalid

Position monitor during ready OFF valid

3 pyfx Normal excitation Position loop excitation fixed (strong) 4 cdir Command polarity (+) Command polarity (–)

5 fdir Position detector polarity (+)

Position detector polarity (–) 6 7

Synchronized tapping position compensation valid 9 A B C

8 phos Normal (no compensation)

od8x Magnification of excessive error width × 8 times invalid

Magnification of excessive error width × 8 times valid

D

ptyp Position control switch typeAfter zero point return
Position control switch typeAfter deceleration stop

E

F zrtn Zero point return direction: CCW

Zero point return directionCW
Show 5 more labels / short text on this page
Standard · range · setting · SP193 SPECT Synchronized · tapping specifications
Page 234 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP194
Page 234 · click to enlarge
Page 234
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

Set the speed loop proportional gain in synchronized tapping mode.

0 to 1000 (1/s)

tapping speed loop gain proportional term

SP195 VGTI Synchronized tapping speed loop gain integral term

Set the speed loop integral gain in synchronized tapping mode.

0 to1000 (0.1 1/s)

Set the speed loop delay advance gain in synchronized tapping mode. When this parameter is set to "0", PI control is applied.

0 to 1000 (0.1 1/s)

tapping speed loop gain delay advance term

3397 SP197 This is used by Mitsubishi. Set to "0" unless particularly designated.

Set the magnification of speed loop proportional gain with respect to SP194 (VGTP) at the maximum motor speed defined in SP017 (TSP) in synchronized tapping mode.

tapping target value of variable speed loop proportional gain

Set the speed where the speed loop proportional gain change starts during synchronized tapping.

0 to 32767 (r/min)

tapping change starting speed of variable speed loop proportional gain

SP194

SP194× (SP198/100)

SP199 SP017

Set the acceleration feed forward gain for selection of gear 000 during synchronized tapping. This parameter should be used when an error of relative position to Z-axis servo is large.

tapping acceleration feed forward gain (gear 1)

Set the acceleration feed forward gain for selection of gear 001 during synchronized tapping.

tapping acceleration feed forward gain (gear 2)

Set the acceleration feed forward gain for selection of gear 010 during synchronized tapping.

tapping acceleration feed forward gain (gear 3)

Show 12 more labels / short text on this page
Standard · range · setting · SP194 VGTP Synchronized · SP196 VGTD Synchronized · SP198 VCGT Synchronized · SP199 VCST Synchronized · Proportional gain · Speed · SP200 FFC1 Synchronized · SP201 FFC2 Synchronized · SP202 FFC3 Synchronized
Page 235 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP204
Page 235 · click to enlarge
Page 235
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

SP203 FFC4 Synchronized tapping acceleration feed forward gain (gear 4)

Set the acceleration feed forward gain for selection of gear 011 during synchronized tapping.

SP204

Not used. Set to "0". 0 0

3414 SP214 TZRN Synchronized tapping zero point return speed

This parameter is valid when SP193 (SPECT) bitE is set to "0". Set the zero point return speed used when the speed loop changes to the position loop.

0 to 500 (r/min)

3415 SP215 TPDT Synchronized tapping zero point return deceleration rate

This parameter is valid when SP193 (SPECT) bitE is set to "0". Set the deceleration rate where the machine starts to decelerate when it returns to the target stop point during synchronized tapping zero point return. When the machine tends to overshoot at the stop point set a smaller value.

0 to 10000 (pulse)

3416 SP216 TPST Synchronized tapping zero point return shift amount

This parameter is valid when SP193 (SPECT) bitE is set to "0". Set the synchronized tapping zero point position.

3417 SP217 TINP Synchronized tapping in-position width

Set the position error range for output of the in-position during synchronized tapping.

SP218 TODR Synchronized tapping excessive error width

Set the excessive error width during synchronized tapping.

1 to 32767 (pulse) (1 pulse =0.088°)

SP219 IQGT Synchronized tapping current loop gain magnifi- cation 1

Set the magnification of current loop gain (torque component) during synchronized tapping.

SP220 IDGT Synchronized tapping current loop gain magnifi- cation 2

Set the magnification of current loop gain (excitation component) during synchronized tapping.

Show 4 more labels / short text on this page
Standard · range · setting · to SP213
Page 236 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP230
Page 236 · click to enlarge
Page 236
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

3421 SP221 PG2T Synchronized tapping position loop gain 2

Set the second position loop gain when high-gain control is applied during synchronized tapping. When this parameter is not used, set to "0".

0 to 999 (1/s)

3422 SP222 PG3T Synchronized tapping position loop gain 3

Set the third position loop gain when high-gain control is applied during synchronized tapping. When this parameter is not used, set to "0".

0 to 999 (1/s)

3423 SP223 SPDV Speed monitor speed

Set the spindle limit speed in the door open state. (Invalid when 0 is set.) If the spindle end speed exceeds this setting value when the door is open, the speed monitor error (5E) will occur.

0 to 800 (r/min)

3424 SP224 SPDF Speed monitor time

Set the time (continuous) to detect alarms. (Detected instantly when 0 is set.)

0 to 2813 (3.5ms)

3425 SP225 OXKPH Position loop gain magni- fication after orientation gain changeover (H coil)

If gain changeover is valid (SP097: SPEC0-bitC=1) during orientation, set the magnification of each gain changed to after in-position.

0 to 2560 (1/256-fold)

3426 SP226 OXKPL Position loop gain magni- fication after orientation gain changeover (L coil)

0 to 2560 (1/256-fold)

3427 SP227 OXVKP Speed loop proportional gain magnifi- cation after orientation gain changeover

0 to 2560 (1/256-fold)

3428 SP228 OXVKI Speed loop cumulative gain magnifi- cation after orientation gain changeover

If gain changeover is valid (SP097: SPEC0-bitC=1) during orientation, set the magnification of each gain changed to after in-position.

0 to 2560 (1/256-fold)

3429 SP229 OXSFT Orientation virtual target shift amount

Set the amount to shift the target position when orientation virtual target position is valid (SP097: SPEC0-bitD=1).

SP230

Use not possible.

Show 4 more labels / short text on this page
Standard · range · setting · to SP232
Page 237 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP251
Page 237 · click to enlarge
Page 237
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

SP233 JL Disturbance observer general inertia scale

Set the ratio of the motor inertia + load inertia and motor inertia.

= ×100 Motor inertia + load inertia

(Normally, set "100" or more. When less than "50" is set, the setting will be invalid.)

SP234 OBS1 Disturbance observer low path filter frequency

Set the frequency of the low path filter for when the disturbance observer is valid.

0 to 1000 (1/s)

Setting (1/s) = 2πf

f: Approx. 1.5 times the disturbance

SP235 OBS2 Disturbance observer gain

Set the gain for the disturbance observer.

3436 SP236 OBS3 This is used by Mitsubishi. Set to "0" unless particularly designated.

SP237 Not used. Set to "0". 0 0

SP238

Use not possible. 0 0

SP242 Vavx 0 0

This is used by Mitsubishi. Set to "0" unless particularly designated.

SP243 UTTM 0 0

SP244 OPLP 0 0

SP245 PGHS 0 0

SP246 TEST

SP247

Use not possible. 0 0

3449 SP249 SM0 Speed meter speed

Set the motor rotation speed when the speed meter 10V is output. When set to "0", this parameter becomes the same as SP017 (TSP).

0 to 32767 (r/min)

3450 SP250 LM0 Load meter voltage

Set the voltage when the load meter 120% is output. When set to "0", this becomes 10V.

0 to 10 (V)

SP251

Use not possible. 0 0

Show 9 more labels / short text on this page
Standard · range · setting · Setting value · Motor inertia · frequency · to SP241 · to SP248 · to SP252
Page 238 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 3453 SP253
Page 238 · click to enlarge
Page 238
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

3453 SP253

DA1NO D/A output channel 1 data number

Set the output data number for channel 1 of the D/A output function. When set to "0", the output is speedometer. Refer to "9.4 (1) For D/A output functions".

3454 SP254 DA2NO D/A output channel 2 data number

Set the output data number for channel 2 of the D/A output function. When set to "0", the output is load meter. Refer to "9.4 (1) For D/A output functions".

3455 SP255 DA1MPY DA output channel 1 magnifica- tion

Set the data magnification for channel 1 of the D/A output function. The output magnification is the setting value divided by 256. When set to "0", the output magnification becomes 1-fold, in the same manner as when "256" is set. Refer to "9.4 (1) For D/A output functions".

–32768 to 32767 (1/256-fold)

3456 SP256 DA2MPY DA output channel 2 magnifica- tion

Set the data magnification for channel 2 of the D/A output function. The output magnification is the setting value divided by 256. When set to "0", the output magnification becomes 1-fold, in the same manner as when "256" is set. Refer to "9.4 (1) For D/A output functions".

–32768 to 32767 (1/256-fold)

Standard · range · setting

Page 239 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP321
Page 239 · click to enlarge
Page 239
8. Spindle Parameters 8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH

No. Items Details Setting

SP257

RPM BSD

Motor constant (H coil)

This parameter is valid only in the following two conditional cases: (a) In case that SP034 (SFNC2) bit0=1

0000 to FFFF HEX setting

and SP034 (SFNC2) bit2=0 Set the motor constants when using a special motor, not described in the SP040 (MTYP) explanation and when not using the coil changeover motor. (b) In case that SP034 (SFNC2) bit0=1

and SP034 (SFNC2) bit2=1 Set the motor constant of the H coil of the coil changeover motor. (Note) It is not allowed for the user to

change the setting.

SP321

RPML BSDL

Motor constant (L coil)

This parameter is valid only in the following conditional case: (a) In case that SP034 (SFNC2) bit0=1

0000 to FFFF HEX setting

and SP034 (SFNC2) bit2=1 Set the motor constant of the L coil of the coil changeover motor. (Note) It is not allowed for the user to

change the setting.

Show 7 more labels / short text on this page
Standard · range · setting · to SP320 · to 3520 (PR) · to SP384 · to 3584 (PR)
Page 240 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — ! CAUTION
Page 240 · click to enlarge
Page 240
8. Spindle Parameters 8.4 MDS-C1-SPM

8.4 MDS-C1-SPM The spindle parameter setting and display method will differ according to the NC being used, so refer to Instruction Manual for each NC and the following spindles.

MELDAS AC Servo and Spindle MDS-C1 Series Specifications Manual BNP-C3000

For parameters marked with a (PR) in the tables, turn the NC power OFF after setting. The parameters will be valid after the power is turned ON again. The "fixed control constants" and "fixed control bits" in this section are set by Mitsubishi.

! CAUTION

! Do not make remarkable adjustments or changes of the parameters as the operation may

become unstable.

! In the explanation on bits, set all bits not used, including blank bits, to “0”.

No. Items Details Setting

3201 SP001 PGM Magnetic sensor and motor built-in encoder orientation position loop gain

As the set value is larger, the orientation time becomes shorter and servo rigidity is increased. However, vibration is increased and the machine becomes likely to overshoot.

0 to 2000 (0.1 1/s)

3202 SP002 PGE Encoder orientation position loop gain

As the set value is larger, the orientation time becomes shorter and servo rigidity is increased. However, vibration is increased and the machine becomes likely to overshoot.

0 to 2000 (0.1 1/s)

3203 SP003 PGC0 C-axis non-cutting position loop gain

Set the position loop gain in C-axis non-cutting mode. During non-cutting (rapid traverse, etc.) with the C axis control, this position loop gain setting is valid.

1 to 200 (1/s)

3204 SP004 OINP Orientation in-position width

Set the position error range in which an orientation completion signal is output.

SP005 OSP Orientation mode changing speed limit value

Set the motor speed limit value to be used when the speed loop is changed to the position loop in orientation mode. When this parameter is set to "0", SP017 (TSP) becomes the limit value.

0 to 32767 (r/min)

3206 SP006 CSP Orientation mode deceleration rate

As the set value is larger, the orientation time becomes shorter. However, the machine becomes likely to overshoot.

3207 SP007 OPST In-position shift amount for orientation

Set the stop position for orientation. (i) Motor built-in encoder, encoder: Set the value by dividing 360° by 4096. (ii) Magnetic sensor: Divide –5° to +5° by 1024 and put 0° for 0.

(i) 0 to 4095

SP008 Not used. Set to "0". 0 0

Show 4 more labels / short text on this page
Standard · range · setting · (ii) –512 to
Page 241 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP011
Page 241 · click to enlarge
Page 241
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

3209 SP009 PGT Synchronized tapping Position loop gain

Set the spindle position loop gain in synchronized tapping mode.

1 to 200 (1/s)

3210 SP010 PGS Spindle synchronous position loop gain

Set the spindle position loop gain in spindle synchronization mode.

1 to 200 (1/s)

SP011

Use not possible. 0 0

SP017 TSP Maximum motor speed

Set the maximum motor speed of the spindle.

1 to 32767 (r/min)

SP018 ZSP Motor zero speed

Set the motor speed for which zero-speed output is performed.

1 to 1000 (r/min)

SP019 CSN1 Speed cushion 1

Set the time constant for a speed command from "0" to the maximum speed. (This parameter is invalid in position loop mode.)

1 to 32767 (10ms)

SP020 SDTS Speed detection set value

Set the motor speed so for which speed detection output is performed. Usually, the setting value is 10% of SP017 (TSP).

0 to 32767 (r/min)

3221 SP021 TLM1 Torque limit 1 Set the torque limit rate for torque limit

signal 001.

SP022 VGNP1 Speed loop

Set the speed loop proportional gain in speed control mode. When the gain is increased, response is improved but vibration and sound become larger.

0 to 1000 (1/s)

gain proportional term under speed control

SP023 VGNI1 Speed loop gain integral term under speed control

Set the speed loop integral gain in speed control mode. Usually, set a value in proportion to SP022 (VGNP1).

0 to 1000 (0.1 1/s)

SP024 Use not possible. 0 0

SP025 GRA1 Spindle gear teeth count 1

Set the number of gear teeth of the spindle corresponding to gear 000.

SP026 GRA2 Spindle gear teeth count 2

Set the number of gear teeth of the spindle corresponding to gear 001.

SP027 GRA3 Spindle gear teeth count 3

Set the number of gear teeth of the spindle corresponding to gear 010.

SP028 GRA4 Spindle gear teeth count 4

Set the number of gear teeth of the spindle corresponding to gear 011.

SP029 GRB1 Motor shaft gear teeth count 1

Set the number of gear teeth of the motor shaft corresponding to gear 000.

Show 4 more labels / short text on this page
Standard · range · setting · to SP016
Page 242 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.4 MDS-C1-SPM
Page 242 · click to enlarge
Page 242
8. Spindle Parameters 8.4 MDS-C1-SPM
Mitsubishi Electronics CNC Controller Board (C64) — 8.4 MDS-C1-SPM diagram (page 242)
Fig. 59

Set the number of gear teeth of the motor shaft corresponding to gear 001.

Set the number of gear teeth of the motor shaft corresponding to gear 010.

Set the number of gear teeth of the motor shaft corresponding to gear 011.

F E D C B A 9 8 poff ront pycal pychg

7 6 5 4 3 2 1 0 pyst pyoff

bit Name Meaning when set to 0 Meaning when set to 1 0 1 2 3 4 5 6 7 8 9 A

B This is used by Mitsubishi. Set to "0" unless particularly designated. C ront Normal ready ON High-speed ready ON

D This is used by Mitsubishi. Set to "0" unless particularly designated. E

F poff Contactor hold at NC power OFF invalid

Page 243 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.4 MDS-C1-SPM
Page 243 · click to enlarge
Page 243
8. Spindle Parameters 8.4 MDS-C1-SPM
Mitsubishi Electronics CNC Controller Board (C64) — 8.4 MDS-C1-SPM diagram (page 243)
Fig. 60

7 6 5 4 3 2 1 0 mkc2 mkch Mk3c mts1

bit Name Meaning when set to 0 Meaning when set to 1

2 mkch Coil switch function invalid Coil switch function valid

3 mkc2 Coil switch specification 2 invalid Coil switch specification 2 valid (Note1) (Note2) 4 5 6 7 8 9 A B C D E F

(Note1) To validate bit3(mkc2), NC side needs to prepare. (Note2) Always turn the bit2 at the same time to use bit3.

Page 244 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.4 MDS-C1-SPM
Page 244 · click to enlarge
Page 244
8. Spindle Parameters 8.4 MDS-C1-SPM
Mitsubishi Electronics CNC Controller Board (C64) — 8.4 MDS-C1-SPM diagram (page 244)
Fig. 61

7 6 5 4 3 2 1 0 mwid lwid hwid (Note) Always set "0" for the empty bits.

bit Name Meaning when set to 0 Meaning when set to 1

M coil output character- istics change valid 3 4 5 6 7 8 9 A B C D E F

Page 245 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.4 MDS-C1-SPM
Page 245 · click to enlarge
Page 245
8. Spindle Parameters 8.4 MDS-C1-SPM
Mitsubishi Electronics CNC Controller Board (C64) — 8.4 MDS-C1-SPM diagram (page 245)
Fig. 62

F E D C B A 9 8 nsno nosg

7 6 5 4 3 2 1 0 plgo enco (Note) Always set "0" for the empty bits.

bit Name Meaning when set to 0 Meaning when set to 1

Encoder orientation valid 1 2 plgo PLG orientation invalid PLG orientation valid 3 4 5 6 7

No-signal detection invalid A B C D E F

(Note) For bit0 to 2, do not set two bits or more to

Page 246 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.4 MDS-C1-SPM
Page 246 · click to enlarge
Page 246
8. Spindle Parameters 8.4 MDS-C1-SPM
Mitsubishi Electronics CNC Controller Board (C64) — 8.4 MDS-C1-SPM diagram (page 246)
Fig. 63

F E D C B A 9 8 XFzs pl80 sdt2

7 6 5 4 3 2 1 0 hzrn orm tdn plg2 pftm alty

bit Name Meaning when set to 0 Meaning when set to 1

Semi-closed pulse output signal×2 valid 4 tdn Fixed control bit 5

Orientation start memo valid 7 hzrn 8 sdt2 9 pl80

A B C XFzs Fixed control bit D E F

Page 247 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.4 MDS-C1-SPM
Page 247 · click to enlarge
Page 247
8. Spindle Parameters 8.4 MDS-C1-SPM
Mitsubishi Electronics CNC Controller Board (C64) — 8.4 MDS-C1-SPM diagram (page 247)
Fig. 64

Set the amplifier type. Set each amplifier type or "0"

7 6 5 4 3 2 1 0 motr

motr Set the motor type. Set "0" when using a special motor.

5 6 7 8 9 A B C D E F

Page 248 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.4 MDS-C1-SPM
Page 248 · click to enlarge
Page 248
8. Spindle Parameters 8.4 MDS-C1-SPM
Mitsubishi Electronics CNC Controller Board (C64) — 8.4 MDS-C1-SPM diagram (page 248)
Fig. 65

F E D C B A 9 8 amp rtyp

7 6 5 4 3 2 1 0 ptyp

When the CN4 connector of the drive unit and the power supply are connected, setting below is necessary. To validate the external emergency stop function, add 40h.

3 Set- ting 0x 1x 2x 3x 4x 5x 6x 7x 8x

8 Set the regenerative resistor type when MDS-A-CR is used.

A 0 MDS-C1-CV (Setting when using power supply regeneration)

This parameter is used to set the C-axis detector range. Set "0" for this parameter. "2" is used by Mitsubishi for testing.

Page 249 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — S
Page 249 · click to enlarge
Page 249
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

This parameter is used to set the synchronous tapping or spindle synchronous detector range. Set "0" for this parameter.

tapping, spindle synchronous detector range

SP044 TRAN

Set a frequency of data communication with NC.

0 to 32767 Standard0 Special: 1028

S

3245 SP045 CSNT Dual cushion timer

Set the cycle to add the increment values in the dual cushion process. When this setting value is increased, the dual cushion will increase, and the changes in the speed during acceleration/deceleration will become gradual.

0 to 1000 (ms)

For an acceleration/deceleration time constant defined in SP019 (CSN1) , this parameter is used to provide smooth movement only at the start of acceleration/deceleration. As the value of this parameter is smaller, it moves smoother but the acceleration/deceleration time becomes longer. To make this parameter invalid, set "0".

Set the reset hysteresis width for a speed detection set value defined in SP020 (SDTS).

0 to 1000 (r/min)

SP048 SUT Speed reach range

Set the speed deviation rate with respect to the commanded speed for output of the speed reach signal.

3249 SP049 TLM2 Torque limit 2 Set the torque limit rate for the torque limit signal 010.

3250 SP050 TLM3 Torque limit 3 Set the torque limit rate for the torque limit signal 011.

3251 SP051 TLM4 Torque limit 4 Set the torque limit rate for the torque limit signal 100.

3252 SP052 TLM5 Torque limit 5 Set the torque limit rate for the torque limit signal 101.

3253 SP053 TLM6 Torque limit 6 Set the torque limit rate for the torque limit signal 110.

3254 SP054 TLM7 Torque limit 7 Set the torque limit rate for the torque limit signal 111.

Set the timer value until the excessive speed deviation alarm is output. The value of this parameter should be longer than the acceleration/deceleration time.

0 to 60 (s) 12

Show 11 more labels / short text on this page
Standard · range · setting · SP043 TRNG Synchronous · NC communi- cation frequency · SP046 CSN2 Speed · command dual cushion · SP047 SDTR Speed · detection reset value · SP055 SETM Excessive · speed deviation timer
Page 250 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.4 MDS-C1-SPM
Page 250 · click to enlarge
Page 250
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

SP056 Use not possible. 0 0

SP057 STOD Constant → excessive judgment value

Set the value for judging when changing from a constant to excessive speed command.

0 to 50 (r/min)

SP058 SDT2 2nd speed detection speed

Set the speed for turning the 2nd speed detection ON. (This is valid only when SP038: SFNC6-bit8 is set to "1".) If the speed drops below this set speed, the 2nd speed detection will turn ON. When the speed reaches this set speed +15r/min or more, the 2nd speed detection will turn OFF. If SP034: SFNC2-bit1 is set to "1", this will be the medium-speed and high-speed coil changeover speed. The speed detection reset width follows the SP047 (speed detection reset width) setting.

0 to 32767 (r/min)

SP059 MKT Winding changeover base shut-off timer

Set the base shut-off time for contactor switching at winding changeover. Note that the contactor may be damaged with burning if the value of this parameter is too small.

50 to 10000 (ms)

SP060 MKT2 Current limit timer after winding changeover

Set the current limit time to be taken after completion of contactor switching at winding changeover.

0 to 10000 (ms)

SP061 MKIL Current limit value after winding changeover

Set the current limit value during a period defined in SP060 (MKT2) after completion of contactor switching at winding changeover.

SP062 Not used. Set to "0". 0 0

SP063 OLT Overload alarm detection time

Set the time constant for detection of the motor overload alarm.

0 to 1000 (s)

SP064 OLL Overload alarm detection level

Set the detection level of the motor overload alarm.

SP065 VCGN1 Target value

Set the magnification of speed loop proportional gain with respect to SP022 (VGNP1) at the maximum motor speed defined in SP017 (TSP).

of variable speed loop proportional gain

Standard · range · setting

Page 251 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.4 MDS-C1-SPM
Page 251 · click to enlarge
Page 251
8. Spindle Parameters 8.4 MDS-C1-SPM
Mitsubishi Electronics CNC Controller Board (C64) — 8.4 MDS-C1-SPM diagram (page 251)
Fig. 66

Set the speed when the speed loop proportional gain change starts.

Set the speed where the current loop gain change starts.

Set the speed where the current loop gain change ends.

SP069 VIGN Target value of variable current loop gain

Set the magnification of current loop gain (torque component and excitation component) for a change ending speed defined in SP068 (VIGWB). When this parameter is set to "0", the magnification is 1.

0 to 6000 6001 to 8000 5000 8000 45 8001 or more 5000 10000 64

When machine vibration occurs in speed and position control, set the frequency of the required vibration suppression. Note that a value of 100Hz or more is set. Set to "0" when not used.

Page 252 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP087
Page 252 · click to enlarge
Page 252
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

3276 SP076 FONS Machine resonance suppression filter operation speed

When the vibration increases in motor stop (ex. in orientation stop) when the machine vibration suppression filter is operated by SP070, operate the machine vibration suppression filter at a speed of this parameter or more. When set to "0", this is validated for all speeds.

0 to 32767 (r/min)

SP077 TDSL Fixed control constant

Set by Mitsubishi. Set "14" unless designated in particular.

SP078 FPWM Fixed control

Set by Mitsubishi. Set "1" unless designated in particular.

SP079 Use not possible. 0 0

3280 SP080 SWTD Fixed control constant

Set by Mitsubishi. Set "0" unless designated in particular.

SP081

Use not possible. 0 0

SP087 DIQM Target value

Set the minimum value of variable torque limit at deceleration.

of variable torque limit magnifica- tion at deceleration

SP088 DIQN Speed for starting change of variable torque limit magnifica- tion at deceleration

Set the speed where the torque limit value at deceleration starts to change.

0 to 32767 (r/min)

Inversely proportional to speed

SP087

SP088 SP017

SP089

Use not possible. 0 0

SP093 ORE Tolerable pulse check error

Set this when detecting the pulse detector's pulse mistakes. (Valid only for full close control.)

SP094 LMAV Load meter

Set the filter time constant of load meter output. When "0" is set, a filter time constant is set to 100ms.

0 to 32767 (2ms)

SP095 VFAV Fixed control

Set by Mitsubishi. Set "0" unless designated in particular.

Show 11 more labels / short text on this page
Standard · range · setting · constant · to SP086 · Torque limit · 100% · Speed · to SP092 · output filter · constant
Page 253 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.4 MDS-C1-SPM
Page 253 · click to enlarge
Page 253
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

SP096 EGAR Encoder gear ratio

Set the gear ratio between the spindle end and the encoder end (except for the motor-built-in encoder) as indicated below.

0 1 : 1 1 1 : 2 2 1 : 4 3 1 : 8 4 1 : 16

(Note) Use a combination so that the encoder

end is slower than the spindle end.

Set the orientation specifications in bit units.

0000 to FFFF HEX setting

F E D C B A 9 8 ostp orze ksft gchg ips2

7 6 5 4 3 2 1 0 vg8x fdir osc1 dmin odi2 odi1

(Note) Always set "0" for the empty bits.

bit Name Meaning when set to 0 Meaning when set to 1 0 odi1

Orientation rotation direction 00: Previous (the direction in which the motor has so far rotated under speed control) 01: Forward rotation 10: Backward rotation 11: Prohibited (Same as setting value = 10)

2 dmin Orientation in-position advance invalid

Orientation in-position advance valid 3

4 osc1 Indexing speed clamp invalid

Indexing speed clamp valid

5 fdir Encoder detector polarity+
Encoder detector polarity– 6

7 vg8x Speed gain *1/8 during torque limit valid

Speed gain *1/8 during torque limit invalid 8 9 A ips2 2nd in-position invalid 2nd in-position valid B

C gchg Gain changeover during orientation invalid

Gain changeover during orientation valid

D ksft Orientation virtual target shift invalid

Orientation virtual target shift valid E orze F ostp

This is used by Mitsubishi. Set to "0" unless particularly designated.

In-position advance (bit 2)

0 (invalid) 1 (valid)

In-position signal in OINP width=1 Control output 4/ bit 4=1 Second in-position signal=0 Control output 4/ bit F=1

In-position signal in OINP width=1 Control output 4/ bit 4=1 Second in-position signal=0 Control output 4/ bit F=0

In-position signal in DINP width=1 Control output 4/ bit 4=1 Second in-position signal in OINP width = 0 Control output 4/ bit F=1

Show 12 more labels / short text on this page
Standard · range · setting · Setting · Gear ratio (deceleration) · value · SP097 SPECO Orientation · specifica- tion · odi2 · 0 (Invalid) · Second in-position · 1 (Valid)
Page 254 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.4 MDS-C1-SPM
Page 254 · click to enlarge
Page 254
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

SP098 VGOP Speed loop

Set the speed loop proportional gain in orientation mode. When the gain is increased, rigidity is improved in the orientation stop but vibration and sound become larger.

0 to 2000 (1/s)

gain propor- tional term in orientation mode

SP099 VGOI Orientation mode speed loop gain integral term

Set the speed loop integral gain in orientation mode.

0 to 2000 (0.1 1/s)

Set a loop gain delay advance gain in orientation mode. When this parameter is set to "0", PI control is applied.

0 to 1000 (0.1 1/s)

mode speed loop gain delay advance term

SP101 DINP Orientation advance in-position width

When using the orientation in-position advance function, set the in-position width that is larger than the normal in-position width defined in SP004 (OINP).

SP102 OODR Excessive error

Set the excessive error width in orientation mode.

0 to 32767 (1/4 pulse) (1 pulse= 0.088°)

value in orientation mode

SP103 FTM Index positioning completion OFF time timer

Set the time for forcedly turn OFF the index positioning completion signal (different from the orientation completion signal) after the leading edge of the indexing start signal.

0 to 10000 (ms)

SP104 TLOR Torque limit

Set the torque limit value for orientation in-position output. If the external torque limit signal is input, the torque limit value set by this parameter is made invalid.

value for orientation servo locking

SP105 IQG0 Current loop gain magnifica- tion 1 in orientation mode

Set the magnification for current loop gain (torque component) at orientation completion.

SP106 IDG0 Current loop gain magnifica- tion 2 in orientation mode

Set the magnification for current loop gain (excitation component) at orientation completion.

3307 SP107 CSP2 Deceleration

Set the deceleration rate in orientation mode corresponding to the gear 001. When this parameter is set to "0", same as SP006 (CSP).

rate 2 in orientation mode

3308 SP108 CSP3 Deceleration

Set the deceleration rate in orientation mode corresponding to the gear 010. When this parameter is set to "0", same as SP006 (CSP).

rate 3 in orientation mode

Show 4 more labels / short text on this page
Standard · range · setting · SP100 VGOD Orientation
Page 255 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP110
Page 255 · click to enlarge
Page 255
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

3309 SP109 CSP4 Deceleration rate 4 in orientation mode

Set the deceleration rate in orientation mode corresponding to the gear 011. When this parameter is set to "0", same as SP006 (CSP).

SP110

Use not possible. 0

3314 SP114 OPER Orientation pulse miss check value

An alarm "5C" will occur if the pulse miss value at the orientation stop exceeds this setting value. (Note that this is invalid when set to "0".) In this parameter, set the value to fulfill the following conditions. SP114 setting value > 1.5 × SP004 (orientation in-position width)

3315 SP115 OSP2 Orientation motor speed clamp value 2

When the orientation clamp speed is changed by the control input, this parameter setting will be used instead of SP005: OSP. Indexing speed clamp valid This parameter is used when (SP097: SPEC0-bit4 = 1).

0 to 32767 (r/min)

SP116 Use not possible. 0 0

3317 SP117 ORUT Set by Mitsubishi. Set "0" unless designated in particular.

3318 SP118 ORCT Number of orientation retry times

Set the number of times to retry when an orientation or feedback error occurs. The warning (A9) is issued while retrying orientation, and an alarm (5C) is issued when the set number of times is exceeded.

0 to 100 (time)

3319 SP119 MPGH Orientation position gain H winding compensa- tion magnifi- cation

Set the compensation magnification of the orientation position loop gain for the H winding. H winding orientation position loop gain = SP001 (or SP002) × SP119/256 When set to "0", will become the same as SP001 or SP002.

0 to 2560 (1/256-fold)

3320 SP120 MPGL Orientation position gain L winding compensa- tion magnifi- cation

Set the compensation magnification of the orientation position loop gain for the L winding. L winding orientation position loop gain = SP001 (or SP002) × SP120/256 When set to "0", will become the same as SP001 or SP002.

0 to 2560 (1/256-fold)

Show 4 more labels / short text on this page
Standard · range · setting · to SP003
Page 256 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP123
Page 256 · click to enlarge
Page 256
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

3321 SP121 MPCSH Orientation deceleration rate H winding compensa- tion magnifi- cation

Set the compensation magnification of the orientation deceleration rate for the H winding. Orientation deceleration rate for the H winding = SP006 × SP121/256 When set to "0", will become the same as SP006.

0 to 2560 (1/256-fol d)

3322 SP122 MPCSL Orientation deceleration rate L winding compensa- tion magnifi- cation

Set the compensation magnification of the orientation deceleration rate for the L winding. Orientation deceleration rate for the L winding = SP006 × SP122/256 When set to "0", will become the same as SP006.

0 to 2560 (1/256-fol d)

SP123

Use not possible. 0 0

3326 SP126 MPGH Orientation position gain M coil com- pensation

Set this to set the orientation position loop gain for the coil changeover motor to the M coil's unique value.

0 to 2560 (1/256- fold)

3327 SP127 MPCSM Orientation deceleration rate M coil compensa- tion

Set this to set the orientation deceleration rate for the coil motor to the M coil's unique value.

0 to 2560 (1/256- fold)

3328 SP128 OXKPM Position loop gain magnifi- cation after orientation gain change- over (M coil)

Set the M coil gain magnification to be used after in-position when gain changeover is valid (SP097: SPEC0-bitC=1) during orientation.

0 to 2560 (1/256- fold)

Show 4 more labels / short text on this page
Standard · range · setting · to SP125
Page 257 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.4 MDS-C1-SPM
Page 257 · click to enlarge
Page 257
8. Spindle Parameters 8.4 MDS-C1-SPM
Mitsubishi Electronics CNC Controller Board (C64) — 8.4 MDS-C1-SPM diagram (page 257)
Fig. 67

F E D C B A 9 8 zrtn ptyp fb9x zrtd zrn2 zdir ztyp

7 6 5 4 3 2 1 0 vg8x fdir phos rtrn fclx

bit Name Meaning when set to 0 Meaning when set to 1

0 fclx Closed loop Semi-closed loop (Gear 1 : 1 only) 1

7 vg8x Speed gain × 1/8 during torque limit valid

Z-phase rising polarity (–) A B zrn2 C zrtd

This is used by Mitsubishi. Set to "0" unless particularly designated.

ptyp Position control switch typeAfter zero point return

3330 SP130 PGC1 First position loop gain for cutting on C-axis

Set the position loop gain when the first gain is selected for C axis cutting.

Page 258 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.4 MDS-C1-SPM
Page 258 · click to enlarge
Page 258
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

3331 SP131 PGC2 Second position loop gain for cutting on C-axis

Set the position loop gain when the second gain is selected for C axis cutting.

1 to 200 (1/s)

3332 SP132 PGC3 Third position loop gain for cutting on C-axis

Set the position loop gain when the third gain is selected for C-axis cutting.

1 to 200 (1/s)

3333 SP133 PGC4 Stop position loop gain for cutting on C-axis

Set the position loop gain for stopping when carrying out C-axis cutting.

1 to 200 (1/s)

SP134 VGCP0∗ C-axis non-cutting speed loop gain proportional item

Set the speed loop proportional gain in C-axis non-cutting mode.

0 to 5000 (1/s)

SP135 VGCI0 C-axis non-cutting speed loop gain integral item

Set the speed loop integral gain in C-axis non-cutting mode.

0 to 5000 (0.1 1/s)

SP136 VGCD0 C-axis non-cutting speed loop gain delay advance item

Set the speed loop delay advance gain in C-axis non-cutting mode. When this parameter is set to "0", PI control is exercised.

0 to 5000 (0.1 1/s)

SP137 VGCP1 First speed loop gain proportional item for C-axis cutting

Set the speed loop proportional gain when the first gain is selected for C-axis cutting.

0 to 5000 (1/s)

SP138 VGCI1 First speed loop gain integral item for cutting on C-axis

Set the speed loop integral gain when the first gain is selected for C-axis cutting.

0 to 5000 (0.1 1/s)

SP139 VGCD1 First speed loop gain delay advance item for cutting on C-axis

Set the speed loop delay advance gain when the first gain is selected for curing on the C-axis. When this parameter is set to "0", PI control is applied.

0 to 5000 (0.1 1/s)

SP140 VGCP2 Second speed loop gain proportional item for cutting on C-axis

Set the speed loop proportional gain when the second gain is selected for C-axis cutting.

0 to 5000 (1/s)

SP141 VGCI2 Second speed loop gain integral item for cutting on C-axis

Set the speed loop integral gain when the second gain is selected for C-axis cutting.

0 to 5000 (0.1 1/s)

SP142 VGCD2 Second speed loop gain delay advance item for cutting on C-axis

Set the speed loop delay advance gain when the second gain is selected for C-axis cutting. When this parameter is set to "0", PI control is applied.

0 to 5000 (0.1 1/s)

Standard · range · setting

Page 259 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — H: 0000 L: 0000
Page 259 · click to enlarge
Page 259
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

SP143 VGCP3 Third speed loop

Set the speed loop proportional gain when the third gain is selected for C-axis cutting.

0 to 5000 (1/s)

gain proportional item for cutting on C-axis

SP144 VGCI3 Third speed loop gain integral item for cutting on C-axis

Set the speed loop integral gain when the third gain is selected for C-axis cutting.

0 to 5000 (0.1 1/s)

SP145 VGCD3 Third speed loop

Set the speed loop delay advance gain when the third gain is selected for C-axis cutting. When this parameter is set to "0", PI control is applied.

0 to 5000 (0.1 1/s)

gain delay advance item for cutting on C-axis

SP146 VGCP4 Speed loop gain

Set the speed loop proportional gain when C-axis cutting is stopped.

0 to 5000 (1/s)

propor- tional item for stop of cutting on C-axis

SP147 VGCI4 Speed loop gain integral item for stop of cutting on C-axis

Set the speed loop integral gain when C-axis cutting is stopped.

0 to 5000 (0.1 1/s)

SP148 VGCD4 Speed loop gain

Set the speed loop delay advance gain when C-axis cutting is stopped. When this parameter is set to "0", PI control is applied.

0 to 5000 (0.1 1/s)

delay advance item for stop of cutting on C-axis

3349 SP149 CZRN C-axis zero point return speed

This parameter is valid when SP129 (SPECC) bitE is set to "0". Set the zero point return speed used when the speed loop changes to the position loop.

1 to 500 (r/min)

3350 SP150 CPDT C-axis zero point return deceleration point

This parameter is valid when SP129 (SPECC) bitE is set to "0". Set the deceleration rate where the machine starts to decelerate when it returns to the target stop point during C-axis zero point return. When the machine tends to overshoot at the stop point, set the smaller value.

3351 SP151 CPSTL C-axis zero point return shift amount (low byte)

This parameter is valid when SPECC (SP129) bitE is set to "0". Set the C-axis zero point position.

HEX setting 00000000 to FFFFFFFF (1/1000°)

H: 0000 L: 0000

3352 SP152 CPSTH C-axis zero point return shift amount (high byte)

Standard · range · setting

Page 260 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP157
Page 260 · click to enlarge
Page 260
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

3353 SP153 CINP C-axis in-position width

Set the position error range in which the in-position signal is output on the C-axis.

0000 to FFFF (1/1000°) HEX setting

03E8

SP154 CODRL Excessive error

Set the excessive error width on the C-axis.

HEX setting 00000000 to FFFFFFFF (1/1000°)

H: 0001 L: D4C0

width on C-axis (low byte)

SP155 CODRH Excessive error

width on C-axis (high byte)

3356 SP156 OVSH C-axis overshoot compensa- tion

Set this to prevent overshooting when shifting from movement to stopping with C-axis control. (Set this referring to the load meter display when overshooting occurred.)

SP157

Not used. Set to "0". 0 0

SP158 Not used. Set to "0". 0 0

SP159 Use not possible. 0 0

SP160 Use not possible. 0 0

SP161 IQGC0 Current loop gain magnifi- cation 1 for non-cutting on C-axis

Set the magnification of current loop gain (torque component) for C-axis non-cutting.

SP162 IDGC0 Current loop gain magnifi- cation 2 for non-cutting on C-axis

Set the magnification of current loop gain (excitation component) for C-axis non-cutting.

SP163 IQGC1 Current loop gain magnifi- cation 1 for cutting on C-axis

Set the magnification of current loop gain (torque component) for C-axis cutting.

SP164 IDGC1 Current loop gain magnifi- cation 2 for cutting on C-axis

Set the magnification of current loop gain (excitation component) for C-axis cutting.

3365 SP165 PG2C C-axis position loop gain 2

Set the second position loop gain when high-gain control is carried out for control of the C-axis. This parameter is applied to all the operation modes of C-axis control. When this function is not used, assign "0".

0 to 999 (1/s)

Standard · range · setting

Page 261 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP171
Page 261 · click to enlarge
Page 261
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

3366 SP166 PG3C C-axis position loop gain 3

Set the third position loop gain when high-gain control is carried out for control of the C-axis. This parameter is applied to all the operation modes of C-axis control. When this function is not used, assign "0".

0 to 999 (1/s)

SP167

PGU Position loop gain for increased spindle holding force

Set the position loop gain for when the disturbance observer is valid.

0 to 100 (1/s)

SP168

VGUP Speed loop gain proportional item for increased spindle holding force

Set the speed loop gain proportional item for when the disturbance observer is valid.

0 to 5000 (1/s)

SP169

VGUI Speed loop gain integral item for increased spindle holding force

Set the speed loop gain integral item for when the disturbance observer is valid.

0 to 5000 (0.1 1/s)

SP170

VGUD Speed loop gain delay advance item for increased spindle holding force

Set the speed loop gain delay advance item for when the disturbance observer is valid.

0 to 5000 (0.1 1/s)

SP171

Not used. Set to "0". 0 0

Show 4 more labels / short text on this page
Standard · range · setting · to SP176
Page 262 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — D
Page 262 · click to enlarge
Page 262
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

Set the spindle synchronous specifications in bit units.

0000 to FFFF HEX setting

F E D C B A 9 8 odx8 phos

7 6 5 4 3 2 1 0 fdir mach fclx

bit Name Meaning when set to 0 Meaning when set to 1 0 fclx Closed loop Semi-closed loop 1 2

3 mach Automatic coil change- over during spindle synchronization invalid

Automatic coil change- over during spindle synchronization valid 4

5 fdir Position detector direc- tion (positive direction)

Position detector direc- tion (negative direction) 6 7 8 9 A B C

Magnification of excessive error width × 8 times valid E F (Used with SPJ)

odx8 Magnification of excessive error width × 8 times invalid

D

SP178 VGSP Spindle synchronous speed loop gain propor- tional term

Set the speed loop proportional gain in spindle synchronous mode.

0 to 2000 (1/s)

SP179 VGSI Spindle synchronous speed loop gain integral term

Set the speed loop integral gain in spindle synchronous mode.

0 to 2000 (0.1 1/s)

SP180 VGSD Spindle synchronous speed loop gain delay advance term

Set the speed loop delay advance gain in spindle synchronous mode. When this parameter is set to "0", PI control is applied.

0 to 1000 (0.1 1/s)

SP181 VCGS Spindle synchronous Target value of variable speed loop proportional gain

Set the magnification of speed loop proportional gain with respect to SP178 (VGSP) at the maximum speed defined in SP017 (TSP) in spindle synchronous mode.

Show 5 more labels / short text on this page
Standard · range · setting · SP177 SPECS Spindle · synchronous specifica- tions
Page 263 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP178
Page 263 · click to enlarge
Page 263
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

SP182 VCSS Spindle synchronous Change starting speed of variable speed loop proportional gain

Set the speed when the speed loop proportional gain change starts in the spindle synchronous mode.

0 to 32767 (r/min)

SP178

SP178× (SP181/100)

SP182 SP017

3383 SP183 SYNV Spindle synchronous Sync match- ing speed

For changeover from the speed loop to the position loop in the spindle synchronous mode, set a speed command error range for output of the synchronous speed matching signal.

0 to 1000 (r/min)

SP184 FFCS Spindle synchronous Acceleration rate feed forward gain

Set the acceleration rate feed forward gain in the spindle synchronous mode. This parameter is used only with the SPJ2.

3385 SP185 SINP Spindle synchronous In-position width

Set the position error range for output of the in-position signal in the spindle synchronous mode.

SP186 SODR Spindle synchronous Excessive error width

Set the excessive error width in the spindle synchronous mode.

1 to 32767 ( pulse) (1 pulse =0.088°)

SP187 IQGS Spindle synchronous Current loop gain magnifi- cation1

Set the magnification of current loop gain (torque component) in the spindle synchronous mode.

SP188 IDGS Spindle synchronous Current loop gain magnifi- cation 2

Set the magnification of current loop gain (excitation component) in the spindle synchronous mode.

3389 SP189 PG2S Spindle synchronous Position loop gain 2

Set the second position loop gain when high-gain control is carried out in the spindle synchronous mode. When this parameter function is not used, set to "0".

0 to 999 (1/s)

Show 5 more labels / short text on this page
Standard · range · setting · Proportional gain · Speed
Page 264 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.4 MDS-C1-SPM
Page 264 · click to enlarge
Page 264
8. Spindle Parameters 8.4 MDS-C1-SPM
Mitsubishi Electronics CNC Controller Board (C64) — 8.4 MDS-C1-SPM diagram (page 264)
Fig. 68

3390 SP190 PG3S Spindle synchronous Position loop gain 3

Set the third position loop gain when high-gain control is carried out in the spindle synchronous mode. When this parameter function is not used, set to "0".

F E D C B A 9 8 zrtn ptyp od8x phos

7 6 5 4 3 2 1 0 fdir cdir pyfx rtrn fclx

bit Name Meaning when set to 0 Meaning when set to 1

0 fclx Closed loop Semi-closed loop (Gear 1 : 1 only) 1

Position monitor during ready OFF valid 3 4 cdir Command polarity (+) Command polarity (–)

Synchronized tapping position command compensation (for synchronization with high-gain servo) 9 A B C

od8x Magnification of excessive error width × 8 times invalid

Magnification of excessive error width × 8 times valid

ptyp Position control switch typeAfter zero point return
Page 265 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP194
Page 265 · click to enlarge
Page 265
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

SP194 VGTP Synchronized tapping speed loop gain proportional term

Set the speed loop proportional gain in synchronized tapping mode.

0 to 2000 (1/s)

SP195 VGTI Synchronized tapping speed loop gain integral term

Set the speed loop integral gain in synchronized tapping mode.

0 to2000 (0.1 1/s)

SP196 VGTD Synchronized tapping speed loop gain delay advance term

Set the speed loop delay advance gain in synchronized tapping mode. When this parameter is set to "0", PI control is applied.

0 to 1000 (0.1 1/s)

SP197 Use not possible. 0 0

SP198 VCGT Synchronized tapping target value of variable speed loop proportional gain

Set the magnification of speed loop proportional gain with respect to SP194 (VGTP) at the maximum motor speed defined in SP017 (TSP) in synchronized tapping mode.

SP199 VCST Synchronized tapping change starting speed of variable speed loop proportional gain

Set the speed where the speed loop proportional gain change starts during synchronized tapping.

0 to 32767 (r/min)

SP194

SP194× (SP198/100)

SP199 SP017

Show 5 more labels / short text on this page
Standard · range · setting · Proportional gain · Speed
Page 266 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP205
Page 266 · click to enlarge
Page 266
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

SP200 FFC1 Synchronized tapping acceleration feed forward gain (gear 1)

Set the acceleration feed forward gain for selection of gear 000 during synchronized tapping. This parameter should be used when an error of relative position to Z-axis servo is large.

SP201 FFC2 Synchronized tapping acceleration feed forward gain (gear 2)

Set the acceleration feed forward gain for selection of gear 001 during synchronized tapping.

SP202 FFC3 Synchronized tapping acceleration feed forward gain (gear 3)

Set the acceleration feed forward gain for selection of gear 010 during synchronized tapping.

SP203 FFC4 Synchronized tapping acceleration feed forward gain (gear 4)

Set the acceleration feed forward gain for selection of gear 011 during synchronized tapping.

SP204

This is used by Mitsubishi. Set to "0" unless particularly designated.

SP205

3406 SP206 GCK Reverse run detection error detection width

When the motor moves (including movement with external force), the motor overrun alarm (3E) will be detected even if the speed command is 0 (including position control stop command) during servo ON (gate ON). Set the movement amount to be detected as an alarm. 0: Detect with 10° motor movement amount (Recommended setting) 1: Detect with 20° motor movement amount 2: Detect with 40° motor movement amount

Show 5 more labels / short text on this page
Standard · range · setting · Fixed control constant · 0/1/2 0
Page 267 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP209
Page 267 · click to enlarge
Page 267
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

3407 SP207 GDL Sequential mode startup timing

To carry out spindle synchronization or C-axis control in the both-chuck state with no movement immediately after the power is turned ON, set this parameter so that the reverse run detection function will function correctly. Set so that servo ON timing for the opposing spindle has the combination of (1) and (2) shown in the drawing below. 0: Servo turns ON simultaneously with servo ON command, and servo ON status is returned immediately. 1: Gate turns ON at pattern (1) shown below, and servo ON status is returned two seconds later. 2: Gate turns ON at pattern (2) shown below, and servo ON status is returned two seconds later.

3408 SP208 W2 This is used by Mitsubishi. Set to "0" unless particularly designated.

SP209

Not used. Set to "0". 0 0

3414 SP214 TZRN Synchronized tapping zero point return speed

This parameter is valid when SP193 (SPECT) bitE is set to "0". Set the zero point return speed used when the speed loop changes to the position loop.

3415 SP215 TPDT Synchronized tapping zero point return deceleration rate

This parameter is valid when SP193 (SPECT) bitE is set to "0". Set the deceleration rate where the machine starts to decelerate when it returns to the target stop point during synchronized tapping zero point return. When the machine tends to overshoot at the stop point set a smaller value.

0 to 10000 (pulse)

3416 SP216 TPST Synchronized tapping zero point return shift amount

This parameter is valid when SP193 (SPECT) bitE is set to "0". Set the synchronized tapping zero point position.

Show 16 more labels / short text on this page
Standard · range · setting · 0/1/2 0 · Servo ON command · Servo ON · Gate ON · Servo ON (1) · 700ms 300ms · Gate ON · 300ms · Servo ON (2) · 700ms · Servo ON status · 2s · to SP213
Page 268 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.4 MDS-C1-SPM
Page 268 · click to enlarge
Page 268
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

3417 SP217 TINP Synchronized tapping in-position width

Set the position error range for output of the in-position during synchronized tapping.

SP218 TODR Synchronized tapping excessive error width

Set the excessive error width during synchronized tapping.

1 to 32767 (pulse) (1 pulse =0.088°)

SP219 IQGT Synchronized tapping current loop gain magnifi- cation 1

Set the magnification of current loop gain (torque component) during synchronized tapping.

SP220 IDGT Synchronized tapping current loop gain magnifi- cation 2

Set the magnification of current loop gain (excitation component) during synchronized tapping.

3421 SP221 PG2T Synchronized tapping position loop gain 2

Set the second position loop gain when high-gain control is applied during synchronized tapping. When this parameter is not used, set to "0".

0 to 999 (1/s)

3422 SP222 PG3T Synchronized tapping position loop gain 3

Set the third position loop gain when high-gain control is applied during synchronized tapping. When this parameter is not used, set to "0".

0 to 999 (1/s)

3423 SP223 SPDV Speed monitor speed

Set the spindle limit speed in the door open state. (Invalid when 0 is set.) If the spindle end speed exceeds this setting value when the door is open, the speed monitor error (5E) will occur.

0 to 800 (r/min)

3424 SP224 SPDF Speed monitor time

Set the time (continuous) to detect alarms. (Detected instantly when 0 is set.)

0 to 2813 (3.5ms)

Standard · range · setting

Page 269 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP230
Page 269 · click to enlarge
Page 269
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

3425 SP225 OXKPH Position loop gain magni- fication after orientation gain changeover (H coil)

If gain changeover is valid (SP097: SPEC0-bitC=1) during orientation, set the magnification of each gain changed to after in-position.

0 to 2560 (1/256-fold)

3426 SP226 OXKPL Position loop gain magni- fication after orientation gain changeover (L coil)

0 to 2560 (1/256-fold)

3427 SP227 OXVKP Speed loop proportional gain magnifi- cation after orientation gain changeover

0 to 2560 (1/256-fold)

3428 SP228 OXVKI Speed loop cumulative gain magnifi- cation after orientation gain changeover

If gain changeover is valid (SP097: SPEC0-bitC=1) during orientation, set the magnification of each gain changed to after in-position.

0 to 2560 (1/256-fold)

3429 SP229 OXSFT Orientation virtual target shift amount

Set the amount to shift the target position when orientation virtual target position is valid (SP097: SPEC0-bitD=1).

SP230

Use not possible.

SP233 JL Disturbance observer general inertia scale

Set the ratio of the motor inertia + load inertia and motor inertia.

= ×100 Motor inertia + load inertia

(Normally, set "100" or more. When less than "50" is set, the setting will be invalid.) To calculate speed loop gain with general inertia scale:

The effective proportional gain and effective cumulative gain during the speed control are changed at the set scale.

SP234 OBS1 Disturbance observer low path filter frequency

Set the frequency of the low path filter for when the disturbance observer is valid.

0 to 1000 (1/s)

Setting (1/s) = 2πf

f: Approx. 1.5 times the disturbance

Show 7 more labels / short text on this page
Standard · range · setting · to SP232 · Setting value · Motor inertia · frequency
Page 270 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP251
Page 270 · click to enlarge
Page 270
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

SP235 OBS2 Disturbance observer gain

Set the gain for the disturbance observer. 0 to 500 (%) 0

3436 SP236 OBS3 Fixed control constant

This is used by Mitsubishi. Set to "0" unless particularly designated.

SP237 KSCP

This is used by Mitsubishi. Set to "0" unless particularly designated.

SP238 SEZR

SP239 SEZT

SP240 Use not possible. 0 0

SP241 Use not possible. 0 0

SP242 Vavx 0 0

This is used by Mitsubishi. Set to "0" unless particularly designated.

SP243 UTTM

SP244 OPLP Use not possible. 0 0

SP245 PGHS 0 0

This is used by Mitsubishi. Set to "0" unless particularly designated.

SP246 TEST

SP247

Use not possible. 0 0

3449 SP249 SM0 Speed meter speed

Set the motor rotation speed when the speed meter 10V is output. When set to "0", this parameter becomes the same as SP017 (TSP).

0 to 32767 (r/min)

3450 SP250 LM0 Load meter voltage

Set the voltage when the load meter 120% is output. When set to "0", this becomes 10V.

0 to 10 (V)

SP251

Use not possible. 0 0

Show 6 more labels / short text on this page
Standard · range · setting · Fixed control constant · to SP248 · to SP252
Page 271 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP321
Page 271 · click to enlarge
Page 271
8. Spindle Parameters 8.4 MDS-C1-SPM

No. Items Details Setting

3453 SP253

DA1NO D/A output channel 1 data number

Set the output data number for channel 1 of the D/A output function. When set to "0", the output is speedometer. Refer to "9.4 (1) For D/A output functions".

3454 SP254 DA2NO D/A output channel 2 data number

Set the output data number for channel 2 of the D/A output function. When set to "0", the output is load meter. Refer to "9.4 (1) For D/A output functions".

3455 SP255 DA1MPY DA output channel 1 magnifica- tion

Set the data magnification for channel 1 of the D/A output function. The output magnification is the setting value divided by 256. When set to "0", the output magnification becomes 1-fold, in the same manner as when "256" is set. Refer to "9.4 (1) For D/A output functions".

–32768 to 32767 (1/256-fold)

3456 SP256 DA2MPY DA output channel 2 magnifica- tion

Set the data magnification for channel 2 of the D/A output function. The output magnification is the setting value divided by 256. When set to "0", the output magnification becomes 1-fold, in the same manner as when "256" is set. Refer to "9.4 (1) For D/A output functions".

–32768 to 32767 (1/256-fold)

SP257

RPM BSD

Motor constant (H coil)

This parameter is valid only in the following two conditional cases: (a) In case that SP034 (SFNC2) bit0=1

0000 to FFFF HEX setting

and SP034 (SFNC2) bit2=0 Set the motor constants when using a special motor, not described in the SP040 (MTYP) explanation and when not using the coil changeover motor. (b) In case that SP034 (SFNC2) bit0=1

and SP034 (SFNC2) bit2=1 Set the motor constant of the H coil of the coil changeover motor. (Note) It is not allowed for the user to

change the setting.

SP321

RPML BSDL

Motor constant (L coil)

This parameter is valid only in the following conditional case: (a) In case that SP034 (SFNC2) bit0=1

0000 to FFFF HEX setting

and SP034 (SFNC2) bit2=1 Set the motor constant of the L coil of the coil changeover motor. (Note) It is not allowed for the user to

change the setting.

Show 7 more labels / short text on this page
Standard · range · setting · to SP320 · to 3520 (PR) · to SP384 · to 3584 (PR)
Page 272 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — MDS–B–SPJ2 MDS–C1–SP
Page 272 · click to enlarge
Page 272
8. Spindle Parameters 8.5 Supplement

8.5 Supplement 8.5.1 D/A Output Specifications (1) D/A output specifications

Mitsubishi Electronics CNC Controller Board (C64) — 8.5 Supplement 8.5.1 D/A Output Specifications (1) D/A output specifications diagram (page 272)
Fig. 69 · 8.5 Supplement 8.5.1 D/A Output Specifications (1) D…

No. of channels 2ch Output cycle 444µs (min. value) Output precision 8bit

0V to +5V (zero) to +10V, 0V to +10V during meter output Output scale setting 1/256 to ±128 tiems

CN9 connector MO1 = 9 pin MO2 = 19 pin GND = 11pin

U–phase current FB7 pin
Mitsubishi Electronics CNC Controller Board (C64) — 8.5 Supplement 8.5.1 D/A Output Specifications (1) D/A output specifications diagram (page 272)
Fig. 70 · 8.5 Supplement 8.5.1 D/A Output Specifications (1) D…

MDS–B–SPJ2 MDS–C1–SP

Page 273 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — SP255, SP256)
Page 273 · click to enlarge
Page 273
8. Spindle Parameters 8.5 Supplement

(2) Setting the output data

Input the No. of the data to be output to each D/A output channel.

# No. Abbrev Parameter name 3453 SP253 DA1NO D/A output channel 1 data No. 3454 SP254 DA2NO D/A output channel 2 data No.

No. Output data Original data unit

for output scale (Setting values in

SP255, SP256)

ch1Speed meter output

10V=max. speed (0=0V)

0 Depends on the max. speed

3.55ms

0 ch2Load meter output

10V=120% load (0=0V) 0 Rated 12%/V 3.55ms

2 Current command Rated 100% = 4096 8 Rated 20%/V 3.55ms

3 Current feedback Rated 100% = 4096 8 Rated 20%/V 3.55ms

4 Speed feedback r/min 13 500rpm/V 3.55ms 5 – 6 Position droop 1° = (64000/65536) 671 10°/V 888µs 7 –

8 Feedrate (F∆T) 1° = (64000/65536) 629 (When communicating by 3.5ms)

9. 10 Position command 1° = (64000/65536) 19 (18.64) 360°/V 888µs 11 – 12 Position feedback 1° = (64000/65536) 19 (18.64) 360°/V 888µs 13 – 80 Control input 1 81 Control input 2 82 Control input 3 83 Control input 4

HEX Bit correspondence 3.55ms

84 Control output 1 85 Control output 2 86 Control output 3 87 Control output 4

HEX Bit correspondence 3.55ms

125 Saw-tooth wave test output

0 (256) Cycle 227.5ms 444µs

126 Rectangular wave test output

0 (256) Cycle 1.7ms 444µs

127 2.5V(data0) test output

0 (256) – 444µs

Show 5 more labels / short text on this page
Standard setting value · Standard output unit · Output · cycle · 500rpm/V 888µs
Page 274 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8.5 Supplement
Page 274 · click to enlarge
Page 274
8. Spindle Parameters 8.5 Supplement

(3) Setting the output scale

# No. Abbrev Parameter name 3455 SP255 DA1MPY D/A output channel 1 magnification 3456 SP256 DA2MPY D/A output channel 2 magnification Usually, the standard setting value is set for the output scale (SV063, SV 064). When “0” is set, the output will be made as well as when “256” is set.

SP255 10 [V] DATA x 256 x 256 (8bit) + 5 [V] (offset) = Output voltage [V]

(Example) When outputting the position droop with 10°/V.

640000 671 10 65536 x 256 x 256 + 5 = 5.999 [V]

Page 275 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 9.1 Function Outline
Page 275 · click to enlarge
Page 275
9. Machine Error Compensation 9.1 Function Outline

9. Machine Error Compensation

9.1 Function Outline

Machine error compensation includes two independent functions: memorized pitch error compensation and memorized relative position compensation.

(1) Memorized pitch error compensation

According to the specified parameters‚ this method compensates an axis feed error caused by a ball screw pitch error‚ etc. With the reference point defined as the base‚ as shown in the following figure, set the compensation amount in the division points obtained by equally dividing the machine coordinates. The compensation amount can be set by either the absolute or incremental system. Select the desired method with the "#4000 Pinc". Machine position is compensated between division points n and n+1 as much as compensation amount between them by linear approximation.

Mitsubishi Electronics CNC Controller Board (C64) — 9.1 Function Outline diagram (page 275)
Fig. 71 · 9.1 Function Outline

Relationship between the compensation amount and machine position

Page 276 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 9. Machine Error Compensation
Page 276 · click to enlarge
Page 276
9. Machine Error Compensation 9.1 Function Outline

(2) Memorized relative position compensation

This method‚ according to the parameters specified in advance‚ compensates the relative position error between two orthogonal axes caused by deflection of the moving stand. For this‚ as shown in the following figure‚ specify the compensation amount in the compensation axis direction in the division points obtained by equally dividing the machine coordinates of the base axis. The base axis is one of the two orthogonal axes to which relative position compensation applies. This axis is used as the criterion for relative-error measurement. The compensation axis is the coordinate axis that is orthogonal to the base axis. The compensation is actually made for this coordinate axis. The section between division points n and n+1 is compensated smoothly by linear approximation.

Mitsubishi Electronics CNC Controller Board (C64) — 9. Machine Error Compensation diagram (page 276)
Fig. 72 · 9. Machine Error Compensation

Relationship between the compensation amount and machine position

Page 277 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 9. Machine Error Compensation
Page 277 · click to enlarge
Page 277
9. Machine Error Compensation 9.1 Function Outline
Mitsubishi Electronics CNC Controller Board (C64) — 9. Machine Error Compensation diagram (page 277)
Fig. 73 · 9. Machine Error Compensation

Specify whether the incremental volume method or absolute volume method is to be used to set machine error offset data.

# Item Details Setting range 4001 cmpax Basic axis Specify the basic axis address for machine error compensation. 1) For pitch error compensation‚ set the name of the axis to be compensated. 2) For relative position compensation‚ set the name of the axis to be the base axis.

X, Y, Z, U, V, W, A, B, or C axis address

4002 drcax Compensation axis

Set the compensation axis address for machine error compensation. 1) For pitch error compensation‚ set the same axis name as "#4001 cmpax". 2) For relative position compensation‚ set the name of the axis to be actually compensated.

X, Y, Z, U, V, W, A, B, or C axis address

4003 rdvno Division point number at reference point position

Set the compensation data No. corre- sponding to the reference point position. The reference point is actually the base‚ so there is no compensation No. Set the number that is decremented by 1.

4004 mdvno Division point number at the most negative side

Set the compensation data No. that is on the farthest negative side.

4005 pdvno Division point number at the most positive side

Set the compensation data No. that is on the farthest positive side.

4006 sc Compensation scale factor

Set the compensation amount’s scale. When the compensation scale is set to “1”, the compensation amount unit will be the same as the output unit.

Compensation amount unit = unit of output × compensation scale

4007 spcdv Division interval Set the interval to divide the basic axis. Each compensation data will be the compensation amount for each of these intervals.

1 to 9999999(µm)

Mitsubishi Electronics CNC Controller Board (C64) — 9. Machine Error Compensation diagram (page 277)
Fig. 74 · 9. Machine Error Compensation

Set the parameters corresponding to the 1st axis’ parameters 4001 to 4007 for each axis. A maximum of 6 axes can be controlled‚ but as the relative position is compensated‚ settings for 10 axes can be made.

Show 10 more labels / short text on this page
<1st axis> · 2nd axis · 3rd axis · 4th axis · 5th axis · 6th axis · 7th axis · 8th axis · 9th axis · 10th axis
Page 278 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 9. Machine Error Compensation
Page 278 · click to enlarge
Page 278
9. Machine Error Compensation 9.1 Function Outline

# Item Details Setting range 4101 y y y 5124

Set the compensation amount for each axis.

–128 to 127 The actual compensation amount will be the value obtained by multiplying the setting value with the compensation scale.

Page 279 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 9.2 Setting Compensation Data
Page 279 · click to enlarge
Page 279
9. Machine Error Compensation 9.2 Setting Compensation Data

9.2 Setting Compensation Data

Compensation data can be set according to either absolute or incremental system. "#4000:Pinc" 0: Absolute system 1: Incremental system (1) Absolute system

Feed from the reference point to each division point is executed as shown in the following figure. The following is obtained at this time. Set it as the compensation amount.

(Specified position – Real machine position) × 2 (Unit of output) For example‚ assume that the feed from the reference point to the +100mm position is executed. Also‚ assume that the real machine position is 99.990mm. In this case‚ the following value is defined as the compensation amount used at the +100mm position:

(100000 – 99990) × 2 = 20 pulses The resultant value is defined as the compensation amount. Assume that the real machine position resulting when feed to the –100mm position is executed‚ is –99.990mm. In this case‚ the following value is defined as the compensation amount used at the –100mm position:

(–100000 – (–99990)) × 2 = –20 pulses

Mitsubishi Electronics CNC Controller Board (C64) — 9.2 Setting Compensation Data diagram (page 279)
Fig. 75 · 9.2 Setting Compensation Data
Page 280 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 9.2 Setting Compensation Data
Page 280 · click to enlarge
Page 280
9. Machine Error Compensation 9.2 Setting Compensation Data

The following figure (left) contains a machine position that is placed in the positive direction with respect to the reference point. Assume that feed from division n–1 to n (division interval) is executed. In this case‚ the following value is defined as the compensation amount:

(Division interval – Actual movement distance) × 2 (Unit of output) The following figure (right) contains a machine position that is placed in the negative direction with respect to the reference point. Assume that feed from division point n+1 to n by the division interval is executed. In this case‚ the following value is defined as the compensation amount:

(Division interval + Actual movement distance) × 2 (Unit of output)

Mitsubishi Electronics CNC Controller Board (C64) — 9.2 Setting Compensation Data diagram (page 280)
Fig. 76 · 9.2 Setting Compensation Data

n: Division point compensation number 1: Division interval

UnitUnit of output Range : –128 to 127

(Note) The unit of output is used as the unit of setting. The actual unit of compensation pulses depends

on the compensation scale factor.

(2) Incremental system

Page 281 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 9.3 Example in Using a Linear Axis as the Base Axis
Page 281 · click to enlarge
Page 281
9. Machine Error Compensation 9.3 Example in Using a Linear Axis as the Base Axis

9.3 Example in Using a Linear Axis as the Base Axis

(1) When "mdvno" or "pdvno" exists at both ends of "rdvno":

Mitsubishi Electronics CNC Controller Board (C64) — 9.3 Example in Using a Linear Axis as the Base Axis diagram (page 281)
Fig. 77 · 9.3 Example in Using a Linear Axis as the Base Axis

Division point number #4101 #4102 #4103 #4104 #4105 #4106 rdvno 4103 Specified machine position −300.000 −200.000 −100.000 100.000 200.000 300.000 mdvno 4101

Real machine position −299.999 −200.000 −100.003 100.002 200.002 299.999 pdvno 4106

Compensation Incremental 2 6 −6 −4 0 6 sc 1

amount Absolute −2 0 6 −4 −4 2 spcdv 100000 If the setting range (mdvno to "pdvno") is exceeded‚ the compensation will be based on compensation amount at mdvno or "pdvno". (2) When the range compensated is only the positive range:

Mitsubishi Electronics CNC Controller Board (C64) — 9.3 Example in Using a Linear Axis as the Base Axis diagram (page 281)
Fig. 78 · 9.3 Example in Using a Linear Axis as the Base Axis

Division point number #4113 #4114 #4115 #4116 #4117 rdvno 4112 Compensation Incremental −4 2 0 6 2 mdvno 4113

amount Absolute −4 −2 −2 4 6 pdvno 4117 If the machine position exceeds "pdvno"‚ the compensation will be based on the compensation amount at "pdvno". If the machine position is negative in this case‚ no compensation will be executed.

Page 282 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 9.3 Example in Using a Linear Axis as the Base Axis
Page 282 · click to enlarge
Page 282
9. Machine Error Compensation 9.3 Example in Using a Linear Axis as the Base Axis

(3) When the range compensated is only the negative range:

Mitsubishi Electronics CNC Controller Board (C64) — 9.3 Example in Using a Linear Axis as the Base Axis diagram (page 282)
Fig. 79 · 9.3 Example in Using a Linear Axis as the Base Axis

Division point number #4125 #4126 #4127 #4128 #4129 #4130 rdvno 4130 Compensation Incremental −2 2 6 2 0 −6 mdvno 4125

amount Absolute −2 −4 −2 4 6 6 pdvno 4130 If the machine position exceeds "mdvno"‚ the compensation will be based on compensation amount at "mdvno". (4) When compensation is executed in a range that contains no reference point:

Mitsubishi Electronics CNC Controller Board (C64) — 9.3 Example in Using a Linear Axis as the Base Axis diagram (page 282)
Fig. 80 · 9.3 Example in Using a Linear Axis as the Base Axis

Division point number #4135 #4136 #4137 #4138 #4139 #4140 rdvno 4134 Compensation Incremental −2 −2 6 2 mdvno 4136

amount Absolute −2 −4 2 4 pdvno 4140 In this case‚ the compensation is executed in the range from "mdvno" to "pdvno". This setting rule applies also when the compensation is executed in a range which contains negative machine positions and no reference point.

Page 283 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 9.4 Example in Using a Rotation Axis as the Base Axis
Page 283 · click to enlarge
Page 283
9. Machine Error Compensation 9.4 Example in Using a Rotation Axis as the Base Axis

9.4 Example in Using a Rotation Axis as the Base Axis

Mitsubishi Electronics CNC Controller Board (C64) — 9.4 Example in Using a Rotation Axis as the Base Axis diagram (page 283)
Fig. 81 · 9.4 Example in Using a Rotation Axis as the Base Axi…

Division point number #4123 #4124 #4125 #4126 #4127 #4128 rdvno 4122 Compensation Incremental −4 2 0 6 2 −6 mdvno 4123

amount Absolute −4 −2 −2 4 6 0 pdvno 4128

In this case‚ the sum of the compensation amounts set according to the incremental system is always 0. For the absolute system‚ the compensation amount at the terminal point (360 degrees) is always 0.

Error · 360°

Page 284 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 10.2 PLC Counter
Page 284 · click to enlarge
Page 284
10. PLC Constants 10.1 PLC Timer

10. PLC Constants

10.1 PLC Timer

(SETUP PARAM 6. 1/6) to (SETUP PARAM 6. 2/6)

# PLC device Item Details Setting range

T000

10ms adding timer

Set the time for the timer used in the PLC program (ladder). (Note) This setting value is valid when

0 to 32767 (×10ms)

T015

parameter "#6449 bit0" in the following "[BIT SELECT]" is set to "0".

T016

100ms adding timer

Set the time for the timer used in the PLC program (ladder). (Note) This setting value is valid when

0 to 32767 (×100ms)

T095

parameter "#6449 bit0" in the following "[BIT SELECT]" is set to "0".

T096

100ms cumulative timer

Set the time for the timer used in the PLC program (ladder). (Note) This setting value is valid when

0 to 32767 (×100ms)

T103

parameter "#6449 bit0" in the following "[BIT SELECT]" is set to "0".

10.2 PLC Counter

(SETUP PARAM 6. 3/6)

# PLC device Item Details Setting range 6200 6223

Counter Set the time for the counter used in the PLC program (ladder). (Note) This setting value is valid when

parameter "#6449 bit1" in the following "[BIT SELECT]" is set to "0".

6000 6015 · 6016 6095 · 6096 6103

Page 285 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — R4594,4595
Page 285 · click to enlarge
Page 285
10. PLC Constants 10.3 PLC Constants

10.3 PLC Constants

(SETUP PARAM 6. 4/6)

# PLC device Item Details Setting range 6301 6348

R4500,4501

PLC constant Set the value to be set in the data type R register used in the PLC program (ladder). Even if the data is set in the R register that corresponds to the PLC side when this parameter is displayed‚ the screen will not change. Enter a different screen once‚ and then select this screen again. Note that some parameters have limited uses.

R4594,4595

6325 Check timer of input signal for safety 6326 Check timer of output signal for safety

Reserved for the system. Used for only C64T.

0 to 32767(X100ms) Standard: 2 Set “0” for C6/C64.

–99999999

Page 286 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — CAUTION
Page 286 · click to enlarge
Page 286
10. PLC Constants 10. 4 PLC Bit Selection

10.4 PLC Bit Selection

(SETUP PARAM 6. 5/6) to (SETUP PARAM 6. 6/6)

# PLC device Item Details Setting range 6401 6402 6495 6496

R4600-Low R4600-High R4647-Low R4647-High

Bit selection This is the bit type parameter used in the PLC program (ladder). Even if the data is set in the R register that corresponds to the PLC side when this parameter is displayed‚ the screen will not change. Enter a different screen once‚ and then select this screen again. Note that some parameters have limited uses.

0: OFF 1: ON

6413 bit0 Dual monitoring interruption

Reserved for the system. Used for only C64T.

0/1 Standard0
0. Detect 1: Not detect 6449

bit6 Communication terminal overheat detected

Designate whether to detect the communication terminal overheat alarm or not. 0: Detects the overheat alarm. 1: Does not detect the overheat alarm.

bit7 Control unit overheat detected

Designate whether to detect the control unit overheat alarm or not. 0: Detects the overheat alarm. 1: Does not detect the overheat alarm.

0. Detect 1: Not detect

bit0 Macro interface for respective part systems

Designate whether to use the macro interface for respective part systems or not.

0. Conventional macro interface common to part systems. 1: Available to respective part systems.

bit0,1 High-speed input specification

bit0: High-speed input from R54. bit1: High-speed input from R55. Note that this is used for only C64T.

bit00/1 bit1: 0/1

bit0,1 High-speed output specification

bit0: High-speed output to R56 bit1: High-speed output to R57 Note that this is used for only C64T.

bit00/1 bit1: 0/1

CAUTION

When setting the parameter (#6449/bit6,7) not to check the overheat, the control unit and

the communication terminal may not be controlled because of overheat. In such case, axis runaway may cause a machine breakage, an accident resulting in injury or death, or device breakage. To prevent the serious results, ordinarily set the parameters so that the overheat check is valid.

0/1

Page 287 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 10.4 PLC Bit Selection
Page 287 · click to enlarge
Page 287
10. PLC Constants 10. 4 PLC Bit Selection
Table"Contents of bit selection parameters #6449 to #6496"
Mitsubishi Electronics CNC Controller Board (C64) — 10.4 PLC Bit Selection diagram (page 287)
Fig. 82 · 10.4 PLC Bit Selection

name 7 6 5 4 3 2 1 0

R2925 L - F0 screen

R2927 L -

R2927 H -

(Note 1) Be sure to set the bits indicated - and blanks to 0. (Note 2) Parameters #6481 to #6496 are reserved for debugging by Mitsubishi. (Note 3) High-speed input specification is valid for only the devices allocated to remote I/O. As for

the devices allocated to the input signals from network such as HR863 Q-bus bridge or H865 CC-Link, high-speed input specification is not applied to. (Note 4) When using C64T system, these parameters are used as follows;

Mitsubishi Electronics CNC Controller Board (C64) — 10.4 PLC Bit Selection diagram (page 287)
Fig. 83 · 10.4 PLC Bit Selection

bit1 High-speed input specification from R55. bit0 High-speed output specification to R56. #6458

Page 288 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 10.4 PLC Bit Selection
Page 288 · click to enlarge
Page 288
10. PLC Constants 10. 4 PLC Bit Selection
Mitsubishi Electronics CNC Controller Board (C64) — 10.4 PLC Bit Selection diagram (page 288)
Fig. 84 · 10.4 PLC Bit Selection

name 7 6 5 4 3 2 1 0

0 #6465 R2932 L -

1 #6466 R2932 H -

2 #6467 R2933 L -

6 #6471 R2935 L -

7 #6472 R2935 H -

(Note 1) Be sure to set the bits indicated - and blanks to 0. (Note 2) Parameters #6481 to #6496 are reserved for debugging by Mitsubishi.

Page 289 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 11. Macro List
Page 289 · click to enlarge
Page 289
11. Macro List

11. Macro List

# Item Details Setting range (unit) 7001 to 7091

M [01] to M [10]

Set the M code used for calling out the macro with the M command. This is valid when "#1195 Mmac" is set to 1.

Set the macro call out type.

0 M98 P∆∆∆∆; and equivalent value call 1 G65 P∆∆∆∆; and equivalent value call 2 G66 P∆∆∆∆; and equivalent value call 3 G66.1 P∆∆∆∆; and equivalent value call others M98 P∆∆∆∆; and equivalent value call

Set the No. of the program to be called out.

M2mac Set the type and program No. for when calling out the macro with the 2nd miscellaneous command. The macro will be called out with the "#1170 M2name" address command when "#1198 M2mac" is set to 1. 7102 Same as the M call macro.

7103 Same as the M call macro.

G [01] to G [10]

Set the G code to be used when calling the macro with a G command. Do not set a G code used in the system.

Same as the M call macro.

Same as the M call macro.

Smac Set the type and program No. for when calling the macro with an S command. This is valid when "#1196 Smac" is set to 1. 7302 Same as the M call macro.

7303 Same as the M call macro.

Tmac Set the type and program No. for when calling the macro with a T command. This is valid when "#1197 Tmac" is set to 1. 7312 Same as the M call macro.

7313 Same as the M call macro.

27000 Nmac Not used. 0 27001 to 27071

N [0] to N [08]

Not used.

Not used.

Page 290 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 12.1 Outline of Function
Page 290 · click to enlarge
Page 290
12. Position Switch 12.1 Outline of Function

12. Position Switch

12.1 Outline of Function

The position switch (PSW) is used as an imaginary dog switch by assigning an axis name and coordinate values that indicate the imaginary dog position to be used instead of the dog switch on the machine axis. When the machine reaches the imaginary dog position, a signal is output to the PLC interface. This imaginary dog switch is called the position switch (PSW).

No. Item Details Setting range (unit) 7500 Pcheck High-speed switching of position switch

Specify whether to perform position switch area checking at high speeds. 0: Does not perform position switch area checking at high speed (do it the same as before). 1: Performs position switch area checking at high speed.

75∗1 Axis name Specify the name of the axis for which a position switch is provided.

X, Y, Z, U, V, W, A, B, or C axis address

75∗2 Imaginary dog position 1

When the machine enters the range between imaginary dog positions 1 and 2, a signal is output to the PLC.

−99999.999

(0.001mm)

75∗3 Imaginary dog position 2

Part system 1 device X 660 Part system 2 device Y 6E0

75∗4 Selection of area check method

When position switch area checking at high speed is selected, specify the mode of area checking, i.e., whether to use the command type machine position or detector feedback position, for each position switch point. 0: Use the command type machine position as the machine position for position switch area checking. 1: Use the detector feedback position as the machine position for position switch area checking. (Note) This parameter is valid only

when 1 set in “#7500 Pcheck.”

0/1 · 0/1

Page 291 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 12. Position Switch
Page 291 · click to enlarge
Page 291
12. Position Switch 12.1 Outline of Function

Position switch numbers of PSW1 to PSW16 and signal devices

1st part system

PSW1 7501 7502 7503 X660 X6E0 X760 X7E0 X860 X8E0 X960 PSW2 7511 7512 7513 X661 X6E1 X761 X7E1 X861 X8E1 X961 PSW3 7521 7522 7523 X662 X6E2 X762 X7E2 X862 X8E2 X962 PSW4 7531 7532 7533 X663 X6E3 X763 X7E3 X863 X8E3 X963 PSW5 7541 7542 7543 X664 X6E4 X764 X7E4 X864 X8E4 X964 PSW6 7551 7552 7553 X665 X6E5 X765 X7E5 X865 X8E5 X965 PSW7 7561 7562 7563 X666 X6E6 X766 X7E6 X866 X8E6 X966 PSW8 7571 7572 7573 X667 X6E7 X767 X7E7 X867 X8E7 X967 PSW9 7581 7582 7583 X670 X6F0 X770 X7F0 X870 X8F0 X970 PSW10 7591 7592 7593 X671 X6F1 X771 X7F1 X871 X8F1 X971 PSW11 7601 7602 7603 X672 X6F2 X772 X7F2 X872 X8F2 X972 PSW12 7611 7612 7613 X673 X6F3 X773 X7F3 X873 X8F3 X973 PSW13 7621 7622 7623 X674 X6F4 X774 X7F4 X874 X8F4 X974 PSW14 7631 7632 7633 X675 X6F5 X775 X7F5 X875 X8F5 X975 PSW15 7641 7642 7643 X676 X6F6 X776 X7F6 X876 X8F6 X976 PSW16 7651 7652 7653 X677 X6F7 X777 X7F7 X877 X8F7 X977

Instead of the dog switch provided on the machine axis‚ the coordinate values indicating imaginary dog positions (dog1 and dog2) on the coordinate axis of the axis name preset with axis are set with the position switches (PSW1 – PSW16). When the machine reaches the position‚ the signal is output to the device corresponding to the PLC interface. Example of settings of dog1 and dog2 and operation

Mitsubishi Electronics CNC Controller Board (C64) — 12. Position Switch diagram (page 291)
Fig. 85 · 12. Position Switch

If dog1 equals dog2‚ the dog1 position triggers a signal.

Show 6 more labels / short text on this page
2nd part system · 3rd part system · 4th part system · 5th part system · 6th part system · 7th part system
Page 292 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 12.2 Canceling the Position Switch
Page 292 · click to enlarge
Page 292
12. Position Switch 12.2 Canceling the Position Switch

Setting of dog1 and dog2 Operation Description

Mitsubishi Electronics CNC Controller Board (C64) — 12.2 Canceling the Position Switch diagram (page 292)
Fig. 86 · 12.2 Canceling the Position Switch

A signal is output between dog1 and dog2.

Mitsubishi Electronics CNC Controller Board (C64) — 12.2 Canceling the Position Switch diagram (page 292)
Fig. 87 · 12.2 Canceling the Position Switch

A signal is also output when dog1 is negative.

Mitsubishi Electronics CNC Controller Board (C64) — 12.2 Canceling the Position Switch diagram (page 292)
Fig. 88 · 12.2 Canceling the Position Switch

A signal is output between dog2 and dog1.

⏐dog1 − dog2⏐ ≥ 360

Mitsubishi Electronics CNC Controller Board (C64) — 12.2 Canceling the Position Switch diagram (page 292)
Fig. 89 · 12.2 Canceling the Position Switch

A signal is kept output when the difference between dog1 and dog2 exceeds 360 degrees.

12.2 Canceling the Position Switch

To cancel the position switch‚ enter the number (#75∗1) of the position switch to be canceled in # ( ) of the setting area‚ enter a slash "/" in DATA ( )‚ then press the INPUT key. This deletes the axis name for the specified position switch‚ thus invalidating the position switch. The data specified for and are still stored in memory. To validate the position switch again‚ therefore‚ it is enough to specify the axis name only.

Rotary axis · dog1 < dog2 · dog1 > dog2

Page 293 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 13. Indexing Axis Parameters
Page 293 · click to enlarge
Page 293
13. Indexing Axis Parameters

13. Indexing Axis Parameters

(Note) These parameters are used only with the G64T.

# Item Details Setting range

METHOD Select the index command method.

0. Matrix command 1: Single command 2: BCD command (without parity) 3: BCD command (with parity)

26252 AUX bit0 Select the rotary axis' control method.

0 to F Set as a HEX value.

0. Non-endless method Positioning is carried out without extending over 0.000°. Thus, the rotation direction is automatically determined according to the command. 1: Endless method Positioning is carried out with the designated rotation direction or a short cut.

bit1 Validates addition/subtraction with the index position command input.

0. Addition/subtraction invalid 1: Addition/subtraction valid bit2 Select the valid width of external data input/output function's IN data.
0. 16 bits (IN0 to IN15) 1: 24 bits (IN0 to IN23) bit3 When the "request fixed" signal is ON, the parity of the IN data equivalent to the valid width set in #26252 bit2 is checked.
0. Does not check parity 1: Checks parity bit4 Select the external positioning stop mode.
0. Retraction stop mode After decelerating to a stop, the axis is retracted to the position where the signal was input (point where deceleration started). Then the index position compensation amount is calculated and set. 1: Deceleration stop mode After decelerating to a stop, the index position compensation amount is calculated and set at that point.

26253 JOG CLAMP SPEED 1 Set JOG speed 1 or indexing speed clamp 1. 26254 JOG CLAMP SPEED 2 Set JOG speed 2 or indexing speed clamp 2. 26255 JOG CLAMP SPEED 3 Set JOG speed 3 or indexing speed clamp 3.

1 to 1000000 (mm/min, °/min)

(unit) 26251 · 0/1/2/3

Page 294 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 13. Indexing Axis Parameters
Page 294 · click to enlarge
Page 294
13. Indexing Axis Parameters

# Item Details Setting range

(unit) 26256 CURRENT LIMIT Set current limit value when current limit value command signal is ON.

26257 OFFSET Set the indexing position compensation amount. -999.999 to 999.999 (mm) 26258 OFFSET LIMIT If the indexing position compensation amount exceeds this value, the "index position offset MAX reached" signal (M:Y18E, L:Y100) will be output.

0 to 999.999 (mm)

26259 DETECTION WIDTH Set the tolerable width for outputting the in-position signal when indexing is completed.

0 to 999.999 (mm) 26260 CURRENT LIMIT 2 Set current limit value when current limit value command 2 signal is ON.

26261 CURRENT LIMIT 3 Set current limit value when current limit value command 3 signal is ON.

Page 295 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 14. Indexing Axis Position Switch 14.1 Outline of Function
Page 295 · click to enlarge
Page 295
14. Indexing Axis Position Switch 14.1 Outline of Function

14. Indexing Axis Position Switch 14.1 Outline of Function

(Note) These parameters are used only with the G64T. The position switch (PSW) is used as an imaginary dog switch by assigning an axis name and coordinate values that indicate the imaginary dog position to be used instead of the dog switch on the machine axis. When the machine reaches the imaginary dog position, a signal is output to the PLC interface. This imaginary dog switch is called the position switch (PSW). The position switch for the indexing axis is set on this screen.

Mitsubishi Electronics CNC Controller Board (C64) — 14. Indexing Axis Position Switch 14.1 Outline of Function diagram (page 295)
Fig. 90 · 14. Indexing Axis Position Switch 14.1 Outline of Fu…

The PLC position output signal turns ON when the machine reaches the range between the imaginary dog position 1 and imaginary dog position 2.

Position switch numbers of PSW1 to PSW16 and signal devices

<dog1> <dog2> 1st axis device

PSW1 27701 27702 R3561/bit0 R3566/bit0 R3571/bit0 R3576/bit0 PSW2 27703 27704 R3561/bit1 R3566/bit1 R3571/bit1 R3576/bit1 PSW3 27705 27706 R3561/bit2 R3566/bit2 R3571/bit2 R3576/bit2 PSW4 27707 27708 R3561/bit3 R3566/bit3 R3571/bit3 R3576/bit3 PSW5 27709 27710 R3561/bit4 R3566/bit4 R3571/bit4 R3576/bit4 PSW6 27711 27712 R3561/bit5 R3566/bit5 R3571/bit5 R3576/bit5 PSW7 27713 27714 R3561/bit6 R3566/bit6 R3571/bit6 R3576/bit6 PSW8 27715 27716 R3561/bit7 R3566/bit7 R3571/bit7 R3576/bit7 PSW9 27717 27718 R3561/bit8 R3566/bit8 R3571/bit8 R3576/bit8 PSW10 27719 27720 R3561/bit9 R3566/bit9 R3571/bit9 R3576/bit9 PSW11 27721 27722 R3561/bitA R3566/bitA R3571/bitA R3576/bitA PSW12 27723 27724 R3561/bitB R3566/bitB R3571/bitB R3576/bitB PSW13 27725 27726 R3561/bitC R3566/bitC R3571/bitC R3576/bitC PSW14 27727 27728 R3561/bitD R3566/bitD R3571/bitD R3576/bitD PSW15 27729 27730 R3561/bitE R3566/bitE R3571/bitE R3576/bitE PSW16 27731 27732 R3561/bitF R3566/bitF R3571/bitF R3576/bitF

(Note) If the imaginary dog positions 1 and 2 are both set to “0”, the signal will not be output to the PLC

interface.

2nd axis device · 3rd axis device · 4th axis device

Page 296 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 15. Indexing Axis Commands
Page 296 · click to enlarge
Page 296
15. Indexing Axis Commands

15. Indexing Axis Commands

(Note) These parameters are used only with the G64T.

Item Details Setting range (unit) POSITION Command the indexing position. –99999.999 to 99999.999

(0.001mm/0.001°,

0.0001mm/0.0001°) SPEED Set the indexing speed. 0 to 999999 (mm/min, °/min) INPOS Set the in-position width, which indicates the output range of the in-position signal output when positioning is completed.

0 to 99999.999 (0.001mm/0.001°,

0.0001mm/0.0001°) FLAG 0: Normal indexing position command 1: Position command valid for external positioning 2: Indexing command compensation valid

100 sets can be set for each axis. When changing the axis, set the axis No. after "X" in the first setting area, such as # (X2), and then press INPUT. Axis No. "1" corresponds to the 1st peripheral axis. (Example 1) To change to 2nd peripheral axis # ( X2) INPUT (Example 2) To change to 4th peripheral axis # ( X4) INPUT

0/1/2

Page 297 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 16. Auxiliary Axis Parameters
Page 297 · click to enlarge
Page 297
16. Auxiliary Axis Parameters
16. Auxiliary Axis Parameters Turn the NC power OFF after setting parameters indicated with a (PR) in the table. The setting will be validated after the power is turned ON again.

No. Name Details Setting range Default

MSR Motor series Set the motor series. This is automatically judged by the system when the default value (0000) is set.

0000 to FFFF (hexadecimal)

RTY Regeneration option type

Set the regenerative resistor type. Do not set values without a description.

0 (Default value)

0 Amplifier standard built-in resistor (10CT has no built-in resistor) 1 Setting prohibited 2 MR-RB032 (30W) 3 MR-RB12 (100W) 4 MR-RB32 (300W) 5 MR-RB30 (300W) 6 MR-RB50 (500W) 7~F

PC1 Motor side gear ratio (machine rotation ratio)

Set the No. of gear teeth on the motor side and the No. of gear teeth on the machine side as an integer reduced to its lowest terms. Set the total gear ratio if there are multiple gear levels. For rotation axes, set the No. of motor rotation speed per machine rotation.

PC2 Machine side gear ratio (motor rotation ratio)

PIT Feed pitch Set 360 (default value) for rotation axes. Set the feed lead for linear axes.

1 to 32767 (° or mm)

6 INP In-position detection width

In-position is detected when the position droop becomes this setting value or less.

1 to 32767 (1/1000° or µm)

value · Setting · value Details

Page 298 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 16. Auxiliary Axis Parameters
Page 298 · click to enlarge
Page 298
16. Auxiliary Axis Parameters

No. Name Details Setting range Default

7 ATU Auto-tuning Set the adjustment of the auto-tuning. Do not set values without a description.

0 1 0 2 (Default setting value)

1 Low response (low-rigidity loads, loads which easily vibrate) 2 Standard setting value 3 Standard setting value 4 Standard setting value

5 High response (high-rigidity loads, loads which do not easily vibrate)

2 Large friction amount (set the position loop gain slightly lower)

0 Only auto-tuning PG2, VG2, VIC, and GD2.

1 Auto-tuning PG1, PG2, VG1, VG2, VIC, and GD2 (total gain). (Standard setting) 2 No auto-tuning.

8 PG1 Position loop gain 1

Set the position loop gain for the model loop. Determine the tracking ability regarding the position commands.

4 to 1000 (1/s) 70

(Not used.) 0

10 EMGt Deceleration control time constant

Set the deceleration time from the clamp speed (Aspeed1). For normal rapid traverse, set the same value as the acceleration/deceleration time constant.

0 to 32768 (ms) 500

(Not used.) 0

(Not used.) 0

13 MBR Vertical axis drop prevention time

Input the time the servo OFF is delayed during servo OFF command. Increase the setting by 100ms at a time and set the minimum value where the axis does not drop.

0 to 1000 (ms) 100

Show 8 more labels / short text on this page
value · Setting · value Details · Setting · value Details · 0 Standard · Setting · value Details
Page 299 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 16. Auxiliary Axis Parameters
Page 299 · click to enlarge
Page 299
16. Auxiliary Axis Parameters

No. Name Details Setting range Default

14 NCH Notch filter No. Set the frequency of the machine resonance suppression filter.

Do not set values without a description.

value 0 1 2 3 4 5 6 7

No start 1125 563 375 282 225 188 161

(Not used.) 0

16 JIT Jitter compensation

Set the No. of ignored jitter compensation pulses. Do not set values without a description.

Setting value 0 1 2 3 Number of ignore

pulses No start 1 2 3

(Not used.) 0

(Not used.) 0

19 PG2 Position loop gain 2

Set the position loop gain of the actual loop. Determine the position responsiveness for external disturbance.

1 to 500 (1/s) 25

20 VG1 Speed loop gain 1

Set the speed loop gain of the model loop. Determine the tracking ability regarding the speed commands.

20 to 5000 (1/s) 1200

21 VG2 Speed loop gain 2

Set the speed loop gain of the actual loop. Determine the speed responsiveness for external disturbance.

20 to 8000 (1/s) 600

22 VIC Speed integral compensation

Determine the characteristics of the speed low-frequency region.

1 to 1000 (ms) 20

23 VDC Speed differential compensation

PI control normally results from a default value of 1000. Adjust the overshoot amount by lowering in increments of 20.

DG2 Load inertia ratio

Set the load inertia ratio for the motor inertia. 0.0 to 50.0 (fold)

(Not used.) 0

MTY Motor type Set the motor type. This is automatically judged by the system when the default value (0000) is set.

0000 to FFFF (hexadecimal)

Show 4 more labels / short text on this page
value · Setting · Frequency · (Hz)
Page 300 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 16. Auxiliary Axis Parameters
Page 300 · click to enlarge
Page 300
16. Auxiliary Axis Parameters
Mitsubishi Electronics CNC Controller Board (C64) — 16. Auxiliary Axis Parameters diagram (page 300)
Fig. 91 · 16. Auxiliary Axis Parameters

Set the Nos. of the data to be output on D/A output channel 1.

Set this value when the zero level of D/A output channel 1 is not suitable.

Set the Nos. of the data to be output on D/A output channel 2. The descriptions are the same as "50 MD1".

Set this value when the zero level of D/A output channel 2 is not suitable.

Set the No. of stations. For linear axes, this value is expressed by: No. of divisions = No. of stations – 1.

Page 301 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 16. Auxiliary Axis Parameters
Page 301 · click to enlarge
Page 301
16. Auxiliary Axis Parameters
Mitsubishi Electronics CNC Controller Board (C64) — 16. Auxiliary Axis Parameters diagram (page 301)
Fig. 92 · 16. Auxiliary Axis Parameters

This is a HEX setting parameter. Set bits without a description to their default values.

bit F E D C B A 9 8 7 6 5 4 3 2 1 0

value 0 1 0

bit Meaning when "0" is set Meaning when "1" is set 0

1 High-speed zero point return after establishment of zero point.

Dog-type return for each zero point return operation. 2 3 4 5 6 7

9 Rotation direction determined by operation control signal (DIR)

Electrical zero point becomes the origin point B C

Rotation direction in operation control signal (DIR) or in the shortcut direction

Rotation direction in the random position command sign direction

Stopper direction is in the sign direction of the stopper amount

Page 302 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 16. Auxiliary Axis Parameters
Page 302 · click to enlarge
Page 302
16. Auxiliary Axis Parameters

No. Name Details Setting range Default

Cont2 Control parameter 2

This is a HEX setting parameter. Set bits without a description to their default values.

bit F E D C B A 9 8 7 6 5 4 3 2 1 0

value 0 1 0 1 1 0

bit Meaning when "0" is set Meaning when "1" is set 0 1 Error not corrected at servo OFF Error corrected at servo OFF 2 Linear axis Rotation axis 3 Station assignment direction CW Station assignment direction CCW 4 Uniform index Non-uniform index 5 DO channel standard assignment DO channel reverse assignment 6 2-wire detector communication 4-wire detector communication 7 Incremental detection Absolute position detection 8 9 A B C D E F

This is a HEX setting parameter. Set bits without a description to their default values.

bit F E D C B A 9 8 7 6 5 4 3 2 1 0

value 0 1

bit Meaning when "0" is set Meaning when "1" is set

0 External emergency stop valid External emergency stop invalid (default value)

1 Dynamic brake stop at emergency stop

Deceleration control stop at emergency stop

2 NC bus emergency stop input valid

NC bus emergency stop input invalid

NC bus emergency stop output invalid 4 5 6 7 8 9 A B C D E F

3 NC bus emergency stop output valid

Show 5 more labels / short text on this page
value · Default · EmgCont Emergency · stop control · Default
Page 303 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 16. Auxiliary Axis Parameters
Page 303 · click to enlarge
Page 303
16. Auxiliary Axis Parameters

No. Name Details Setting range Default

tleng Linear axis stroke length

Set the movement stroke length for linear axes. This is meaningless when setting non-uniform assignments or commanding random positions.

0.001 to 99999.999 (mm)

100.000

110 ZRNspeed Reference point return speed

Set the clamp value of the feedrate when a reference point return is carried out. The feedrate becomes the manual operation speed of the parameter group selected at that time, but it is clamped by this parameter setting value.

1 to 100000 (°/min or mm/min)

111 ZRNcreep Reference point return creep speed

Set the approach speed to the reference point after dog detection during a reference point return.

1 to 65535 (°/min or mm/min)

112 grid mask Grid mask Set the amount that the dog is artificially extended. Set 1/2 the grid spacing as a standard.

0 to 65536 (1/1000° or µm)

Divide the grid spacing that is the conventional motor rotation movement amount into 2, 4, 8, or 16 divisions.

0 to 4 (1/2n division)

114 ZRNshift Reference point shift amount

Set the shift amount in a dog-type reference point return from the electric zero point determined on the grid to the reference point.

0 to 65536 (1/1000° or µm)

115 ST. ofset Station offset

Set the distance (offset) from the reference point to station 1.

–99999.999 to 99999.999 (° or mm)

When movement of the machine coordinate zero point from the origin point is required during absolute position initializing, set that movement amount.

–99999.999 to 99999.999 (° or mm)

117 Limit (+) Soft limit (+) Commands in the plus direction that exceed this

–99999.999 to 99999.999 (mm)

setting value are not possible. If the machine is in a position exceeding the setting value, commands in the minus direction are possible. The soft limit function will not operate if Limit (+) and Limit (–) are set to the same value.

118 Limit (–) Soft limit (–) Commands in the minus direction that exceed this

–99999.999 to 99999.999 (mm)

value are not possible. If the machine is in a position exceeding the setting value, commands in the plus direction are possible.

Show 4 more labels / short text on this page
value · grspc Grid spacing · ABS base Absolute · position zero point
Page 304 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 16. Auxiliary Axis Parameters
Page 304 · click to enlarge
Page 304
16. Auxiliary Axis Parameters

No. Name Details Setting range Default

120 ABS Type Absolute position detection parameter

This parameter is set as a hexadecimal. Set the default value for bits that have no description.

bit F E D C B A 9 8 7 6 5 4 3 2 1 0

value 0 1 0 0

bit Meaning when "0" is set Meaning when "1" is set 0 1 Dogless-type method initializing Dog-type method initializing

Origin point alignment method initializing 3 Electrical zero point direction (+) Electrical zero point direction (–) 4 5 6 7 8 9 A B C D E F

2 Mechanical stopper method initializing

Absolute position power OFF tolerable movement value

Set the value for the tolerable amount of movement for a machine that moved during power OFF in an absolute position detection system. The "Absolute position power OFF movement exceeded (ABS)" signal will turn ON if the machine moves more than this setting value during power OFF. The movement amount is not checked when this parameter is set to 0.000.

0.000 to 99999.999 (° or mm)

130 backlash Backlash compensa- tion amount

Set the backlash compensation amount. 0 to 9999 (1/1000° or µm)

(Not used.) 0

(Not used.) 0

(Not used.) 0

(Not used.) 0

value · Default · 123 ABS check

Page 305 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 16. Auxiliary Axis Parameters
Page 305 · click to enlarge
Page 305
16. Auxiliary Axis Parameters

< Operation parameter group 1 >

No. Name Details Setting range Default

150 Aspeed1 Operation parameter group 1 Automatic operation speed

Set the feedrate during automatic operation when operation parameter group 1 is selected. This parameter is regarded as the clamp value for the automatic operation speeds and manual operation speeds of all operation groups. A speed exceeding Aspeed1 cannot be commanded, even if set in the parameters.

1 to 100000 (°/min or mm/min)

151 Mspeed1 Operation parameter group 1 Manual operation speed

Set the feedrate during manual operation or JOG operation when operation parameter group 1 is selected.

1 to 100000 (°/min or mm/min)

152 time1.1 Operation parameter group 1 Acceleration/ deceleration time constant 1

Set the linear acceleration/deceleration time for Aspeed 1(the operation parameter group 1 automatic operation speed (clamp speed)) when operation parameter group 1 is selected. When operating at speeds less than the clamp speed, the axis will linearly accelerate/decelerate at the inclination determined above. When this is set together with acceleration/deceleration time constant 2, S-shape acceleration/deceleration is carried out. In this case, set the acceleration/deceleration time of the linear part in this parameter.

1 to 9999 (ms) 100

153 time1.2 Operation parameter group 1 Acceleration/ deceleration time constant 2

Set this parameter when carrying out S-shape acceleration/deceleration. When S-shape acceleration/deceleration is carried out, set the total time of the non-linear parts. When "1" is set in this parameter, linear acceleration/deceleration is carried out. In the handle feed operation mode, this set value is regarded as the time constant for the linear acceleration/deceleration.

1 to 999 (ms) 1

value

Page 306 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 16. Auxiliary Axis Parameters
Page 306 · click to enlarge
Page 306
16. Auxiliary Axis Parameters

No. Name Details Setting range Default

154 TL1 Operation parameter group 1 Torque limit value

Set the motor output torque limit value when operation parameter group 1 is selected. At the default value, the torque is limited at the maximum torque of the motor specifications. Set the default value when torque limit is not especially required. In the stopper positioning operation mode, this becomes the torque limit value when positioning to the stopper starting coordinates.

155 OD1 Operation parameter group 1 Excessive error detection width

Set the excessive error detection width when operation parameter group 1 is selected. An alarm of excessive error (S03 0052) is detected when the position droop becomes larger than this setting value. In the stopper positioning operation mode, this becomes the excessive error detection width when positioning to the stopper starting coordinates.

0 to 32767 (° or mm)

156 just1 Operation parameter group 1 Set position output width

The signal indicating that the machine position is at any one of the stations is the set position reached (JST) signal. During automatic operation, the automatic set position reached (JSTA) signal is also output under the same conditions. Set the tolerable values at which these signals are output when operation parameter group 1 is selected. These signals turn OFF when the machine position is separated from the station by more than this value.

0.000 to 99999.999 (° or mm)

157 near1 Operation parameter group 1 Near set position output width

The signal indicating that the machine position is near any one of the station positions is the near set position (NEAR) signal. Set the tolerable value at which this signal is output when operation parameter group 1 is selected. This value is generally set wider than the set position output width. During operations, this is related to special commands when the station selection is "0".

0.000 to 99999.999 (° or mm)

value

Page 307 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 16. Auxiliary Axis Parameters
Page 307 · click to enlarge
Page 307
16. Auxiliary Axis Parameters

< Operation parameter group 2 >

No. Name Details Setting range Default

158 Aspeed2 Operation parameter group 2 Automatic operation speed

Set the feedrate during automatic operation when operation parameter group 2 is selected.

1 to 100000 (°/min or mm/min)

159 Mspeed2 Operation parameter group 2 Manual operation speed

Set the feedrate during manual operation or JOG operation when operation parameter group 2 is selected.

1 to 100000 (°/min or mm/min)

160 time2.1 Operation parameter group 2 Acceleration/ deceleration time constant 1

Set the linear acceleration/deceleration time for the operation parameter group 1 automatic operation speed (clamp speed) when operation parameter group 2 is selected. When operating at speeds less than the clamp speed, the axis will linearly accelerate/decelerate at the inclination determined above. When this is set together with acceleration/deceleration time constant 2, S-shape acceleration/deceleration is carried out. In this case, set the acceleration/deceleration time of the linear part in this parameter.

1 to 9999 (ms) 100

161 time2.2 Operation parameter group 2 Acceleration/ deceleration time constant 2

Set this parameter when carrying out S-shape acceleration/deceleration. When S-shape acceleration/deceleration is carried out, set the total time of the non-linear parts. When 1 is set in this parameter, linear acceleration/deceleration is carried out. In the handle feed operation mode, this set value is regarded as the time constant for the linear acceleration/deceleration.

1 to 9999 (ms) 1

value

Page 308 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 16. Auxiliary Axis Parameters
Page 308 · click to enlarge
Page 308
16. Auxiliary Axis Parameters

No. Name Details Setting range Default

162 TL2 Operation parameter group 2 Torque limit value

Set the motor output torque limit value when operation parameter group 2 is selected. At the default value, the torque is limited at the maximum torque of the motor specifications. Set the default value when torque limit is not especially required. In the stopper positioning operation mode, this becomes the torque limit value during stopper operation.

163 OD2 Operation parameter group 2 Excessive error detection width

Set the excessive error detection width when operation parameter group 2 is selected. An excessive error alarm (S03 0052) is detected when the position droop becomes larger than this setting value. In the stopper positioning operation mode, this becomes the excessive error detection width during stopper operation.

0 to 32767 (° or mm)

164 just2 Operation parameter group 2 Set position output width

The signal indicating that the machine position is at any one of the stations is the set position reached (JST) signal. During automatic operation, the automatic set position reached (JSTA) signal is also output under the same conditions. Set the tolerable values at which these signals are output when operation parameter group 2 is selected. These signals turn OFF when the machine position is separated from the station by more than this value.

0.000 to 99999.999 (° or mm)

165 near2 Operation parameter group 2 Near set position output width

The signal indicating that the machine position is near any one of the station positions is the near set position (NEAR) signal. Set the tolerable values at which these signals are output when operation parameter group 2 is selected. These values are generally set wider than the set position output width. During operations, this is related to special commands when the station selection is “0”.

0.000 to 99999.999 (° or mm)

value

Page 309 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 16. Auxiliary Axis Parameters
Page 309 · click to enlarge
Page 309
16. Auxiliary Axis Parameters

< Operation parameter group 3 >

No. Name Details Setting range Default

166 Aspeed3 Operation parameter group 3 Automatic operation speed

Set the feedrate during automatic operation when operation parameter group 3 is selected.

1 to 100000 (°/min or mm/min)

167 Mspeed3 Operation parameter group 3 Manual operation speed

Set the feedrate during manual operation or JOG operation when operation parameter group 3 is selected.

1 to 100000 (°/min or mm/min)

168 time3.1 Operation parameter group 3 Acceleration/ deceleration time constant 1

Set the linear acceleration/deceleration time for the operation parameter group 1 automatic operation speed (clamp speed) when operation parameter group 3 is selected. When operating at speeds less than the clamp speed, the axis will linearly accelerate/decelerate at the inclination determined above. When this is set together with acceleration/deceleration time constant 2, S-shape acceleration/deceleration is carried out. In this case, set the acceleration/deceleration time of the linear part in this parameter.

1 to 9999 (ms) 100

169 time3.2 Operation parameter group 3 Acceleration/ deceleration time constant 2

Set this parameter when carrying out S-shape acceleration/deceleration. When S-shape acceleration/deceleration is carried out, set the total time of the non-linear parts. When 1 is set in this parameter, linear acceleration/deceleration is carried out. In the handle feed operation mode, this set value is regarded as the time constant for the linear acceleration/deceleration

1 to 9999 (ms) 1

value

Page 310 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 16. Auxiliary Axis Parameters
Page 310 · click to enlarge
Page 310
16. Auxiliary Axis Parameters

No. Name Details Setting range Default

170 TL3 Operation parameter group 3 Torque limit value

Set the motor output torque limit value when operation parameter group 3 is selected. At the default value, the torque is limited at the maximum torque of the motor specifications. Set the default value when torque limit is not especially required. In the stopper positioning operation mode, this becomes the pressing torque limit value after completion of the positioning.

171 OD3 Operation parameter group 3 Excessive error detection width

Set the excessive error detection width when operation parameter group 3 is selected. An excessive error alarm (S03 0052) is detected when the position droop becomes larger than this setting value. In the stopper positioning operation mode, this becomes the excessive error detection width during pressing after completion of the positioning.

0 to 32767 (° or mm)

172 just3 Operation parameter group 3 Set position output width

The signal indicating that the machine position is at any one of the stations is the set position reached (JST) signal. During automatic operation, the automatic set position reached (JSTA) signal is also output under the same conditions. Set the tolerable values at which these signals are output when operation parameter group 3 is selected. These signals turn OFF when the machine position is separated from the station by more than this value.

0.000 to 99999.999 (° or mm)

173 near3 Operation parameter group 3 Near set position output width

The signal indicating that the machine position is near any one of the station positions is the near set position (NEAR) signal. Set the tolerable values at which these signals are output when operation parameter group 3 is selected. These values are generally set wider than the set position output width. During operations, this is related to special commands when the station selection is “0”.

0.000 to 99999.999 (° or mm)

value

Page 311 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 16. Auxiliary Axis Parameters
Page 311 · click to enlarge
Page 311
16. Auxiliary Axis Parameters

< Operation parameter group 4 >

No. Name Details Setting range Default

174 Aspeed4 Operation parameter group 4 Automatic operation speed

Set the feedrate during automatic operation when operation parameter group 4 is selected.

1 to 100000 (°/min or mm/min)

175 Mspeed4 Operation parameter group 4 Manual operation speed

Set the feedrate during manual operation or JOG operation when operation parameter group 4 is selected.

1 to 100000 (°/min or mm/min)

176 time4.1 Operation parameter group 4 Acceleration/ deceleration time constant 1

Set the linear acceleration/deceleration time for the operation parameter group 1 automatic operation speed (clamp speed) when operation parameter group 4 is selected. When operating at speeds less than the clamp speed, the axis will linearly accelerate/decelerate at the inclination determined above. When this is set together with acceleration/deceleration time constant 2, S-shape acceleration/deceleration is carried out. In this case, set the acceleration/deceleration time of the linear part in this parameter.

1 to 9999 (ms) 100

177 time4.2 Operation parameter group 4 Acceleration/ deceleration time constant 2

Set this parameter when carrying out S-shape acceleration/deceleration. When S-shape acceleration/deceleration is carried out, set the total time of the non-linear parts. When 1 is set in this parameter, linear acceleration/deceleration is carried out. In the handle feed operation mode, this set value is regarded as the time constant for the linear acceleration/deceleration.

1 to 9999 (ms) 1

value

Page 312 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 16. Auxiliary Axis Parameters
Page 312 · click to enlarge
Page 312
16. Auxiliary Axis Parameters

No. Name Details Setting range Default

178 TL4 Operation parameter group 4 Torque limit value

Set the motor output torque limit value when operation parameter group 4 is selected. At the default value, the torque is limited at the maximum torque of the motor specifications. Set the default value when torque limit is not especially required. In the stopper method initializing mode in absolute position detection systems, this becomes the torque limit value during stopper operation.

179 OD4 Operation parameter group 4 Excessive error detection width

Set the excessive error detection width when operation parameter group 4 is selected. An excessive error alarm (S03 0052) is detected when the position droop becomes larger than this setting value. In the stopper method initializing mode in absolute position detection systems, this becomes the excessive error detection width during stopper operation.

0 to 32767 (° or mm)

180 just4 Operation parameter group 4 Set position output width

The signal indicating that the machine position is at any one of the stations is the set position reached (JST) signal. During automatic operation, the automatic set position reached (JSTA) signal is also output under the same conditions. Set the tolerable values at which these signals are output when operation parameter group 4 is selected. These signals turn OFF when the machine position is separated from the station by more than this value.

0.000 to 99999.999 (° or mm)

181 near4 Operation parameter group 4 Near set position output width

The signal indicating that the machine position is near any one of the station positions is the near set position (NEAR) signal. Set the tolerable values at which these signals are output when operation parameter group 4 is selected. These values are generally set wider than the set position output width. During operations, this is related to special commands when the station selection is “0”.

0.000 to 99999.999 (° or mm)

value

Page 313 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 8 9 A B C D E F
Page 313 · click to enlarge
Page 313
16. Auxiliary Axis Parameters

No. Name Details Setting range Default

190 stpos2 Station 2 coordinate value

Set the coordinate value of each station when non-uniform assignment is selected. The station 1 coordinate value is fixed at 0.000 (machine coordinate zero point).

–99999.999 to 99999.999 (° or mm)

191 stpos3 Station 3 coordinate value

192 stpos4 Station 4 coordinate value

193 stpos5 Station 5 coordinate value

194 stpos6 Station 6 coordinate value

195 stpos7 Station 7 coordinate value

196 stpos8 Station 8 coordinate value

197 stpos9 Station 9 coordinate value

200 PSWcheck PSW detection method

This is a HEX setting parameter. Set bits without a description to their default values.

bit F E D C B A 9 8 7 6 5 4 3 2 1 0

value 0

switch Meaning when "0" is set Meaning when "1" is set

0 PSW1 1 PSW2 2 PSW3 3 PSW4 4 PSW5 5 PSW6 6 PSW7 7 PSW8

The position switch output is judged by the machine position of the command system.

The position switch output is judged by the machine FB position (actual position).

8 9 A B C D E F

value · Default · bit Position

Page 314 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — 16. Auxiliary Axis Parameters
Page 314 · click to enlarge
Page 314
16. Auxiliary Axis Parameters

No. Name Details Setting range Default

201 202 PSW1dog1 PSW1dog2

PSW1 area setting 1 PSW1 area setting 2

When the machine position is in the region between region settings 1 and 2, the position switch of each No. will turn ON. Whether the value of setting 1 is larger than setting 2 (vice versa) does not affect the position switch operation. For rotation axes, the output turns ON at the region without including 0.000 degree.

-99999.999 to 99999.999 (° or mm)

203 204 PSW2dog1 PSW2dog2

PSW2 area setting 1 PSW2 area setting 2

205 206 PSW3dog1 PSW3dog2

PSW3 area setting 1 PSW3 area setting 2

207 208 PSW4dog1 PSW4dog2

PSW4 area setting 1 PSW4 area setting 2

209 210 PSW5dog1 PSW5dog2

PSW5 area setting 1 PSW5 area setting 2

211 212 PSW6dog1 PSW6dog2

PSW6 area setting 1 PSW6 area setting 2

213 214 PSW7dog1 PSW7dog2

PSW7 area setting 1 PSW7 area setting 2

215 216 PSW8dog1 PSW8dog2

PSW8 area setting 1 PSW8 area setting 2

220 push Stopper amount

Set the command stroke of the stopper operation during stopper positioning operations.

0.000 to 359.999 (° or mm)

221 pusht1 Stopper standby time

Set the standby time from the stopper starting coordinate positioning to the stopper operation start during stopper positioning operations.

0 to 9999 (ms) 0

222 pusht2 Stopper torque release time

Set the time from the completion of the stopper operation to the changeover of the stopper torque during stopper positioning operations.

0 to 9999 (ms) 0

223 pusht3 Set position signal output delay time

Set the time from the completion of the stopper operation to the output of the automatic set position reached (JSTA), set position reached (JST), and near set position (NEAR) signals during stopper positioning operations.

0 to 9999 (ms) 0

value

Page 315 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — Revision History
Page 315 · click to enlarge
Page 315

Revision History

Date of revision Manual No. Revision details

Dec. 2000 BNP-B2267* First edition created.

  • Sep. 2003 BNP-B2267A
  • The cover (front, spine, back covers) design was changed.
  • "Type", "Independent Product Code" and "Reference No." were added to the back cover.
  • The following parameters were added. (1) 5. Basic specification parameters

#1926 IP address #21025 SmpDelay

#1927 Subnet mask #21028 ed_mess

#1928 Gateway address #21029 NCname

#1929 Port number #21030 AlmHold

#21049 SPname (2) 16. Indexing axis parameters (#26251 ~ ) (3) 17. Indexing axis position switch (#27701 ~ ) (4) 18 Indexing axis commands • Mistakes, etc. were corrected.

  • Mar.2004 BNP-B2267C
  • The contents revised following to the software Ver.C and Ver.D.
  • Sections of servo parameters (section 7 to 9) were revised all over, and reconstructed to “7. Servo Parameters”.
  • Sections of spindle parameters (section 10 and 11) were revised all over, and reconstructed to “8. Spindle Parameters”.
  • “19 Auxiliary Axis Parameters” was revised all over and its section number became “16”.
  • Mistakes, etc. were corrected.

#21031 UnitMax · #21032 UnitNum

Page 316 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — © 2000-2004 MITSUBISHI ELECTRIC CORPORATION ALL RIGHTS RESERVED
Page 316 · click to enlarge
Page 316

Notice

Every effort has been made to keep up with software and hardware revisions in the contents described in this manual. However, please understand that in some unavoidable cases simultaneous revision is not possible. Please contact your Mitsubishi Electric dealer with any questions or comments regarding the use of this product.

Duplication Prohibited

This instruction manual may not be reproduced in any form, in part or in whole, without written permission from Mitsubishi Electric Corporation.

© 2000-2004 MITSUBISHI ELECTRIC CORPORATION ALL RIGHTS RESERVED

Page 317 of the Mitsubishi Electronics CNC Controller Board (C64) user manual — (0403) MEE
Page 317 · click to enlarge
Page 317

MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE : MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

MODEL

MC6/C64/C64T

MODEL

CODE

Manual No.

BNP-B2267C(ENG)

Specifications subject to change without notice.

(0403) MEE

Printed in Japan on recycled paper.

008-046

Ask about the Mitsubishi Electronics CNC Controller Board (C64)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Mitsubishi Electronics CNC Controller Board (C64)

Be the first to ask — other owners or our team will answer.

Original document

Mitsubishi Electronics CNC Controller Board (C64) manual PDF

317 pages·3 MB·Crib Toy·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…