Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The instructions given in this manual are concerned with this product. For the safety instructions of the programmable controller system, please read the CPU module user's manual. In this manual, the safety instructions are ranked as "DANGER" and "CAUTION".
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage. CAUTION
Please save this manual to make it accessible when required and always forward it to the end user. [Design Precautions]
Depending on the GOT main unit, communication board, communication module or cable fault, the
output from the GOT interface module may remain ON or may remain OFF. An external monitoring circuit should be provided to check for output signals which may lead to a serious accident. Not doing so can cause an accident due to false output or malfunction.
If a communication fault (including cable disconnection) occurs during monitoring on the GOT,
communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative. For bus connection : The CPU becomes faulty and the GOT inoperative. For other than bus connection : The GOT becomes inoperative. A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur. Not doing so can cause an accident due to false output or malfunction.
Do not use the GOT as the warning device that may cause a serious accident.
An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning. Failure to observe this instruction may result in an accident due to incorrect output or malfunction.

DANGER
Incorrect operation of the touch switch(s) may lead to a serious accident if the GOT backlight is
gone out. When the GOT backlight goes out, the display section turns black and causes the monitor screen to appear blank, while the input of the touch switch(s) still remains active. This may confuse an operator in thinking that the GOT is in “screensaver” mode, who then tries to release the GOT from this mode by touching the display section, which may cause a touch switch to operate. Note that the following occurs on the GOT when the backlight goes out.
The monitor screen disappears even when the screensaver is not set. The monitor screen will not come back on by touching the display section, even if the screensaver is set.
Do not bundle the control and communication cables with main-circuit, power or other wiring.
Run the above cables separately from such wiring and keep them a minimum of 100mm apart. Not doing so noise can cause a malfunction.
DANGER
Before installing or removing the GOT main unit to or from an enclosure, always turn the GOT
power OFF before installing or removing the GOT main unit to or from an enclosure. Not doing so can cause a module failure or malfunction.
interface module or memory card interface module to or from the GOT, always turn the GOT power OFF before loading or unloading the communication board, communication module, external I/O interface module or memory card interface module to or from the GOT. Not doing so can cause a module failure or malfunction.
The GOT should be used in the environment given in the general specifications of this user's
manual. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.
When mounting the GOT main unit to an enclosure, tighten the mounting screws in the specified
torque range. Undertightening can cause a drop, short circuit or malfunction. Overtightening can cause a drop, short circuit or malfunction due to the damage of the screws or module.

CAUTION
to the GOT main unit, fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range. Undertightening can cause a drop, failure or malfunction. Overtightening can cause a drop, failure or malfunction due to the damage of the screws or module.
When loading the communication board to the GOT main unit, take care not to become injured by
the components that are installed or surrounding materials.
When loading the communication board to the GOT main unit, remove any static electricity
accumulated on your body before engaging in work. Otherwise, this may result in damage to the board.
DANGER
Before starting wiring, always turn the GOT power OFF before starting wiring.
Not doing so may cause an electric shock, product damage or malfunction.
Please make sure to ground FG terminal of the GOT power supply unit by applying Class D
Grounding (Class 3 Grounding Method) or higher which is used exclusively for the GOT. Not doing so may cause an electric shock or malfunction.
Correctly wire the power supply module on the GOT after confirming the rated voltage and
terminal arrangement of the product. Not doing so can cause a fire or failure.
Tighten the terminal screws of the GOT power supply section in the specified torque range.
Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or module.
Exercise care to avoid foreign matter such as chips and wire offcuts entering the module.
Not doing so can cause a fire, failure or malfunction.
Plug the bus connection cable by inserting it into the connector of the connected module until it
"clicks". After plugging, check that it has been inserted snugly. Not doing so can cause a malfunction due to a contact fault.
Plug the communication cable into the connector of the connected module and tighten the
mounting and terminal screws in the specified torque range. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or module.

DANGER
Before performing test operation (bit device on/off, word device's present value changing, timer/
counter's set value and present value changing, buffer memory's present value changing) for a user-created monitor screen or system monitoring, read the manual carefully to fully understand how to operate the equipment. During test operation, never change the data of the devices which are used to perform significant operation for the system. False output or malfunction can cause an accident.
DANGER
When opening the panel on which the GOT is installed, always power off the GOT.
Not doing so can cause the GOT to fail or malfunction.
When power is on, do not touch the terminals.
Doing so can cause an electric shock or malfunction.
Do not change the extension number setting switch and I/O slot setting switch setting during
power-on. Doing so can cause a malfunction.
Before starting cleaning or terminal screw retightening, always turn the power OFF before starting
cleaning or terminal screw retightening. Not switching the power off in all phases can cause a module failure or malfunction. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or module.
When touching the GOT, communication unit, and/or option unit, or before touching the panel with
the GOT installed, touch a grounded metal object to discharge the static electricity from the human body. Failure to do so may cause the unit to fail or malfunction.
Do not disassemble or modify the module.
Doing so can cause a failure, malfunction, injury or fire.
Do not touch the conductive and electronic parts of the module directly.
Doing so can cause a module malfunction or failure.
The cables connected to the module must be run in ducts or clamped.
Not doing so can cause the module or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault.
When unplugging the cable connected to the module, do not hold and pull the cable portion.
Doing so can cause the module or cable to be damaged or can cause a malfunction due to a cable connection fault.

DANGER
Before changing the backlight, always turn the GOT power OFF (when using a GOT bus
connection, also turn OFF the PLC CPU power), and remove the GOT main unit from the panel before changing the backlight. Not switching the power off in all phases may cause an electric shock. Not removing the unit from the enclosure can cause injury due to a drop.
When replacing the backlight, use the gloves.
Otherwise, it may cause you to be injured. If you should directly touch the plated area of the main unit case with hand, be sure to wipe off the fingerprint and so on, and install the main unit case. Otherwise, it may cause a trouble or malfunction.
Start changing the backlight more than 5 minutes after switching the GOT power off.
Not doing so can cause a burn due to the heat of the backlight.
CAUTION
When disposing of the product, handle it as industrial waste.

The manual number is given on the bottom left of the back cover..

Japanese Manual Version SH-080011-H
This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses.
Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may
occur as a result of using the contents noted in this manual.
A - 7


For details of the manuals relevant to this product, refer to the PDF manual stored within the drawing software used.

Abbreviations and generic terms Description
A950GOT Generic term of A950GOT-TBD, A950GOT-SBD, A950GOT-SBD-B, A950GOT-LBD, A950GOT-TBD-M3, A950GOT-SBD-M3, A950GOT-SBD-M3-B and A950GOT-LBD-M3
A951GOT Generic term of A951GOT-TBD, A951GOT-SBD, A951GOT-SBD-B, A951GOT-LBD, A951GOT-TBD-M3, A951GOT-SBD-M3, A951GOT-SBD-M3-B and A951GOT-LBD-M3
A951GOT-Q Generic term of A951GOT-QTBD, A951GOT-QSBD, A951GOT-QSBD-B, A951GOT-QLBD, A951GOT-QTBD-M3, A951GOT-QSBD-M3, A951GOT-QSBD-M3-B and A951GOT-QLBD-M3
A953GOT Generic term of A953GOT-TBD, A953GOT-SBD, A953GOT-SBD-B A953GOT-LBD, A953GOT-TBD-M3, A953GOT-SBD-M3, A953GOT-SBD-M3-B and A953GOT-LBD-M3
A956GOT Generic term of A956GOT-TBD, A956GOT-SBD, A956GOT-SBD-B, A956GOT-LBD, A956GOT-TBD-M3, A956GOT-SBD-M3, A956GOT-SBD-M3-B and A956GOT-LBD-M3 A95* GOT Generic term of A956GOT, A953GOT, A951GOT, A951GOT-Q and A950GOT A956WGOT Abbreviation of A956WGOT-TBD
Bus connection board Generic term of A9GT-50WQBUSS and A9GT-50WBUSS
Serial communica- tion board Generic term of A9GT-50WRS4 and A9GT-50WRS2
Bus connection unit Generic term of A9GT-QBUS2SU, A9GT-BUSSU, A9GT-BUS2SU, A7GT-BUSS and A7GT-BUS2S Data link unit Generic term of A7GT-J71AP23, A7GT-J71AR23 and A7GT-J71AT23B Network unit Generic term of A9GT-QJ71LP23, A9GT-QJ71BR13, A7GT-J71LP23 and A7GT-J71BR13 CC-Link communi- cation unit Generic term of A8GT-J61BT13 and A8GT-J61BT15
Ethernet communi- cation unit Abbreviation of A9GT-J71E71-T
External I/O unit Abbreviation of A8GT-50KBF type external I/O interface unit Printer interface unit Abbreviation of A9GT-50PRF type Printer interface unit
Memory card inter- face unit Abbreviation of A1SD59J-MIF type Memory card interface unit
Backlight Abbreviation of A9GT-50LT type backlight Debug stand Abbreviation of A9GT-50STAND and A9GT-50WSTAND type debug stand
Memory board Abbreviation of A9GT-FNB, A9GT-FNB1M, A9GT-FNB2M, A9GT-FNB4M, A9GT-FNB8M, A9GT- QFNB, A9GT-QFNB4M, A9GT-QFNB8M type option function memory board Ten-key Panel Abbreviation of A8GT-TK ten-key Panel A7GT-CNB Abbreviation of A7GT-CNB bus connector conversion box A9GT-QCNB Abbreviation of A9GT-QCNB bus connector conversion box Protection sheet Abbreviation of A9GT-50PSC and A9GT-50WPSC type transparent protection sheets PC card (memory card) Generic term of flash PC card, commercially available flash PC card and SRAM PC card
Compact flash PC card Abbreviation of commercially available compact flash PC card
Attachment Abbreviation of A85GT-95ATT attachment
GT Works Version 5 Abbreviation of SW5D5C-GTWORKS-E(-V) software GT Designer Ver- sion 5 Abbreviation of SW5D5C-GOTR-PACKE(V) software
GT Works2 Version1 Abbreviation of SW1D5C-GTWK2-E software
GT Designer2 Version1 Abbreviation of SW1D5C-GTD2-E software
GT Designer Abbreviation of image creation software GT Designer for GOT900 GT Designer2 Abbreviation of image creation software GT Designer2 for GOT900 GT Simulator Abbreviation of GT Simulator screen simulator GOT900 GT Simulator2 Abbreviation of GT Simulator2 screen simulator GOT900 GT Converter Abbreviation of data conversion software GT Converter for GOT900 GT Debugger Abbreviation of debugging software GT Debugger GT Manager Abbreviation of GT Manager data editing software for GOT900 GT SoftGOT Abbreviation of GT SoftGOT monitoring software GT SoftGOT2 Abbreviation of GT SoftGOT2 monitoring software GX Developer Generic term of SW D5C-GPPW-E/SW D5F-GPPW-E software packages
GX Simulator Generic term of SW D5C-LLT-E ladder logic test tool function software package (SW5D5C-LLT-E or later) Acrobat Reader Abbreviation of Adobe Acrobat Reader

Abbreviations and generic terms Description
QCPU (Q Mode) Generic term of Q00JCPU, Q00CPU, Q01CPU,Q02CPU, Q02HCPU, Q06HCPU, Q12HCPU, Q25HCPU, Q12PHCPU and Q25PHCPU CPU QCPU (A Mode) Generic term of Q02CPU-A, Q02HCPU-A and Q06HCPU-A CPU
Remote I/O station Network module for MELSECNET/H network system remote I/O station (QJ72LP25-25, QJ72LP25G, QJ72BR15) QCPU Generic term of QCPU (Q Mode) and QCPU (A Mode)
QnACPU Type Generic term of Q2ACPU, Q2ACPU-S1, Q2AHCPU, Q2AHCPU-S1, Q3ACPU, Q4ACPU and Q4ARCPU CPU QnASCPU Type Generic term of Q2ASCPU, Q2ASCPU-S1, Q2ASHCPU and Q2ASHCPU-S1 CPU QnACPU Generic term of QnACPU Type and QnASCPU Type AnUCPU Generic term of A2UCPU, A2UCPU-S1, A3UCPU and A4UCPU CPU AnACPU Generic term of A2ACPU, A2ACPU-S1 and A3ACPU CPU AnNCPU Generic term of A1NCPU, A2NCPU, A2NCPU-S1 and A3NCPU CPU AnCPU Type Generic term of AnUCPU, AnACPU and AnNCPU CPU AnUS(H)CPU Generic term of A2USCPU, A2USCPU-S1 and A2USHCPU-S1 CPU
AnS(H)CPU Generic term of A1SCPU, A1SCPUC24-R2, A2SCPU, A2SCPU-S1, A1SHCPU, A2SHCPU and A2SHCPU-S1 CPU A1SJ(H)CPU Generic term of A1SJCPU, A1SJCPU-S3 and A1SJHCPU CPU AnSCPU Type Generic term of A2US(H)CPU, AnS(H)CPU and A1SJ(H)CPU CPU
ACPU Generic term of AnCPU Type, AnSCPU Type, A1FXCPU, A0J2HCPU, A2CCPU, A2CCPU24 and A2CJCPU CPU
FXCPU Generic term of FX0 series, FX0N series, FX0S series, FX1 series, FX1N series, FX1S series, FX2 series, FX2C series, FX2N series, FXINS series, FX2NC and FX3UC series CPU
Generic term of A273UCPU, A273UHCPU, A273UHCPU-S3, A373CPU, A373UCPU, A373UCPU- S3, A171SCPU, A171SCPU-S3, A171SCPU-S3N, A171SHCPU, A171SHCPUN, A172SHCPU, A172SHCPUN, A173UHCPU, A173UHCPU-S1, Q172CPU, Q173CPU, Q172CPUN, Q173CPUN CPU FA controller Generic term of LM610, LM7600, LM8000 CPU Peripheral connec- tion mod- ule
G4 Abbreviation of AJ65BT-G4-S3
E71 Generic term of AJ71E71-S3, A1SJ71E71-B2-S3, A1SJ71E71-B5-S3, AJ71E71N-B2, AJ71E71N- B5T, A1SJ71E71N-B2 and A1SJ71E71N-B5T
Generic term of AJ71QE71, A1S 1-B2, AJ71QE71-B5, A1SJ71QE71-B5, AJ71QE71N-B2, AJ71QE71N-B5T, A1SJ71QE71N-B2 and A1SJ71QE71N-B5T Q series-compatible E71 Generic term of QJ71E71, QJ71E71-B2 and QJ71E71-100
Generic term of C200HS, C200H, C200H series(C200HX, C200HG, C200HE), CQM1, C1000H,C2000H,CV500, CV1000, CV2000, CVM1-CPU11, CVM1-CPU21, CS1, CS1D, CJ1M, CPM1, CPM1A, CPM2A, CPM2C CPU, CQM1H
Yaskawa PLC Generic term of GL60S, GL60H, GL70H, GL120, GL130, CP-9200SH, CP-9300MS, MP-920, MP- 930, MP-940, CP-9200(H) and PROGIC-8 CPU
SLC500 Series Generic term of SLC500-20, SLC500-30, SLC500-40, SLC5/01 SLC5/02, SLC5/03, SLC5/04 SLC5/ 05
Generic term of 1761-L10BWA, 1761-L10BWB, 1761-L16AWA, 1761-L16BWA, 1761-L16BWB, 1761-L16BBB, 1761-L32AWA, 1761-L32BWA, 1761-L32BWB, 1761-L32BBB, 1761-L32AAA, 1761- L20AWA-5A, 1761-L20BWA-5A, 1761-L20BWB-5A MicroLogix1500 Series Abbreviation of 1764-LSP Allen-Bradley PLC Generic term of SLC 500 Series, MicroLogix1000 Series, MicroLogix1500 Series
Sharp PLC Generic term of JW-21CU, JW-22CU, JW-31CUH, JW-32CUH, JW-33CUH, JW-50CUH, JW-70CUH, JW-100CUH, JW-100CU, Z-512J CPU PROSEC T Series Generic term of T2(PU224 type), T2E, T2N, T3, T3H CPU PROSEC V Series Generic term of S2T, Model3000(S3) CPU Toshiba PLC Generic term of PROSEC T Series and PROSEC V Series SIEMENS PLC Generic term of SIMATIC S7-300 Series and SIMATIC S7-400 Series CPU
Large type H series Generic term of H-302(CPU2-03H), H-702(CPU2-07H), H-1002(CPU2-10H), H-2002(CPU2-20H), H- 4010(CPU3-40H),.J-300(CPU-03Ha), H-700(CPU-07Ha), H-2000(CPU-20Ha)
H200 to 252 Series Generic term of H-200(CPU-02H, CPE-02H), H-250(CPU21-02H), H-252(CPU22-02H), H- 252B(CPU22-02HB), H-252C(CPU22-02HC, CPE22-02HC)
H Series board type Generic term of H-20DR, H-28DR, H-40DR, H-64DR, H-20DT, H-28DT, H-40DT, H-64DT, HL-40DR, HL-64DR EH-150 Series Generic term of EH-CPU104, EH-CPU208, EH-CPU308, EH-CPU316 HITACHI PLC (HIDIC H Series) Generic term of large type H series, H-200 to 252 Series H Series board type, EH-150 Series
Matsushita Electric Works PLC
Generic term of FP0-C16CT, FP0-C32CT, FP1-C24C, FP1-C40C, FP2, FP2SH, FP3, FP5, FP10(S), FP10SH, FP-M(C20TC) and FP-M(C32TC)
Memory abbreviation of memory (flash memory) in the GOT OS Abbreviation of GOT system software Object Setting data for dynamic image Personal Computer Personal computer where the corresponding software package is installed Servo amplifier Generic term of the MR-J2S- A, MR-J2S- CP and MR-J2M A series MELDAS C6/C64 Generic term of the FCA C6, FCA C64

After unpacking, confirm that you have received the following products.
GOT main unit 1
* For use when closing the bus connec-
tion board setting switch confirmation
hole.
A951GOT-QTBD(-M3)/QSBD(-M3)/QSBD(-M3)-B/QLBD(-M3),
A951GOT-TBD(-M3)/SBD(-M3)/SBD(-M3)-B/LBD(-M3),
A953GOT-TBD(-M3)/SBD(-M3)/SBD(-M3)-B/LBD(-M3),
A956GOT-TBD(-M3)/SBD(-M3)/SBD(-M3)-B/LBD(-M3) User's Manual (Hardware) *
A956WGOT-TBD User's Manual (Hardware) *
* Changes with the GOT you purchased.

This user's manual explains the specifications, handling and other information of the A950GOT/A951GOT/ A953GOT/A956GOT/A956WGOT graphic operation terminal module (abbreviated to the GOT).
The GOT can be used as an electronic operator panel which has achieved on its monitor screen the switch operation, lamp indication, data display, message display and other operations which were previously per- formed on an operator panel.
The following GOT types are available.
Interface built into main unit Display section
A950GOT-SBD
A950GOT-SBD-B
A950GOT-LBD
A950GOT-TBD-M3
A950GOT-SBD-M3
A950GOT-SBD-M3-B
A950GOT-LBD-M3
A951GOT-QTBD
A951GOT-QSBD-B
TBD(-M3): 256
A951GOT-QLBD
STN color liquid crystal
A951GOT-QTBD-M3
M3)-B: 8
(For QCPU (Q Mode))
A951GOT-QSBD-M3
A951GOT-QSBD-M3-B
A951GOT-TBD
A951GOT-SBD
A951GOT-SBD-B
A951GOT-LBD
A951GOT-TBD-M3
A951GOT-SBD-M3
A951GOT-SBD-M3-B
A951GOT-LBD-M3

The following GOT types are available.
Interface built into main unit Display section
A953GOT-SBD
A953GOT-SBD-B
A953GOT-LBD
A953GOT-TBD-M3
A953GOT-SBD-M3
A953GOT-LBD-M3
TBD(-M3): 256
SBD(-M3), SBD(-
STN color liquid crystal
A956GOT-SBD
M3)-B: 8
A956GOT-SBD-B
A956GOT-LBD
A956GOT-SBD-M3
A956GOT-SBD-M3-B
A956GOT-LBD-M3
A956WGOT-TBD 18 (7) Built-in communication


(1) Medium-size display device occupying minimum installation area The A95 GOT/A956WGOT was made smaller in outline dimensions to greatly reduce the panel cut dimensions. You can install the GOT according to your application.

59 mm (2.32 in) for A95 GOT-TBD,A95 GOT-SBD(-M3)-B,A95 GOT-QSBD(-M3)-B.
(2) Fast data transfer of OS and screen data by memory card The PC card for OS and screen data can be created easily on a personal computer. By loading the created card into the memory card interface unit, you can exchange the OS and screen data rapidly. (RS-232C data transfer can also be made as conventionally.) Also, a compact flash PC card can be used with the A956WGOT.

* ROM_BIOS cannot be installed with the compact flash PC card.

1.1 Features 1 - 3

(3) Compatible with a wide variety of connection forms The GOT models each contain their communication interfaces so that you can choose the connection form which meets your system. The A951GOT-Q, A951GOT comes with a bus communication interface to make a bus connection for fast communication, the A953GOT has an RS-232C interface and A950GOT includes an RS- 422 communication interface to make a CPU direct connection or computer link connection. The A956GOT used with a communication module can make a bus connection, MELSECNET connection or CC-Link connection. The A956WGOT used with a communication module or communication board can make a bus connection, Direct connection to CPU, computer link connection, MELSECNET connection, CC- Link connection or Ethernet connection.
(4) Heavy-duty body usable in rigorous environment and operation The standard display section of the GOT complies with the IP67 and the NEMA4 Waterproof, Dustproof Standard and is usable in a wide range of environment.
(5) Maintenance function further enhanced in affinity with PLC Upgraded alarm history function The GOT can support the failure occurrence counting function, cumulative failure time totalizing function and history printing function, and start ladder monitoring with the corresponding device searched with a single keystroke at the failure detail display time.
(6) Improvement of safety by upgraded security function
(7) Wide, easy-to-see screen (A956WGOT only) The A956WGOT can lay out more objects on the screen than it is possible with the A95 GOT. By
utilizing the monitor screen data of the A95 GOT, the A956WGOT enables numeric value entry without hiding the monitor screen with a window for numeric value entry. This is achieved by arranging the ten keys for numeric value input next to the monitor screen data.

Numeric values can be entered without hiding the monitor screen with a window for numeric value entry.

This chapter explains the system configuration of the GOT. 2.1 Overall Configuration
(1) Overall configuration of the A95*GOT The overall configuration of the A95*GOT is shown below.
Communication cable/ module connected
A9GT-50STAND
A9GT-50LT
e.g. A30R4-25P
Bar Code Reader 1
Bus cable for QCPU(Q mode) 1
e.g. A9GT-QC150BS
e.g. A8GT-C12NB
A85GT-C05H
A8GT-50KBF
A9GT-50PRF
e.g. A9GT-Q71LP23
Memory card interface module 2 2 Printer cable 1 Printer 1
PC card (Memory card)
(e.g. key board)
A1SD59J-MIF e.g. AC30PI0-20P
e.g. A8GT-TK
*1 For details of the system configuration, refer to the [GOT-A900 Series User's Manual (Con- nection System Manual)].
*2 For details on the system configuration, refer to the User's Manual of each module.
*3 The A95*GOT-SBD(-M3)-B, A95*GOT-QSBD(-M3)-B and A95*GOT-TBD(-M3) do not require their backlights to be replaced since they are installed with long-life backlights.
2.1 Overall Configuration 2 - 1

(2) Overall configuration of the A956WGOT The overall configuration of the A956WGOT is shown below.

Memory board Protective sheet Debug Stand Compact flash PC card
Memory card interface module 2 2 Printer cable 1 Printer 1
*1 For details of the system configuration, refer to the [GOT-A900 Series User's Manual (Con- nection System Manual)].
*2 For details on the system configuration, refer to the User's Manual of each module.


Each GOT incorporates a different type of communication interface and, therefore, the connection mode dif- fers from GOT to GOT used. The connections modes allowed for each GOT are shown below.
1 The A956GOT can be connected as shown above by the installation of the communication unit.
2 The A956WGOT can be connected as shown above by the installation of the communication unit and the commu-
3 For details of each connection mode, refer to the GOT-A900 Series User's Manual (Connection System Manual).
(1) List of Components Available for the A95*GOT
A950GOT-TBD High intensity TFT color liquid crystal, 256 colors, 1M byte built-in memory
A950GOT-SBD STN color liquid crystal, 8 colors, 1M byte built-in memory
A950GOT-SBD-B High intensity STN color liquid crystal, 8 colors, 1M built-in memory
A950GOT-LBD Monochrome liquid crystal, Monochrome, 1M byte built-in memory
High intensity TFT color liquid crystal, 256 colors, 3M byte built-in memory, compatible with
A950GOT-SBD-M3 STN color liquid crystal, 8 colors, 3M byte built-in memory, compatible with optional OS
High intensity STN color liquid crystal, 8 colors, 3M built-in memory, compatible with optional
OS
A950GOT-LBD-M3 Monochrome liquid crystal, Monochrome, 3M byte built-in memory, compatible with optional OS

2.2 System Configuration of the GOT 2 - 3

A951GOT-QTBD High intensity TFT color liquid crystal, 256 colors,1M byte built-in memory
A951GOT-QSBD STN color liquid crystal, 8 colors,1M byte built-in memory
A951GOT-QSBD-B High intensity STN color liquid crystal, 8 colors, 1M built-in memory
A951GOT-QLBD Monochrome liquid crystal, Monochrome,1M byte built-in memory
High intensity TFT color liquid crystal, 256 colors, 3M byte built-in memory, compatible with
QCPU
A951GOT-QSBD-M3 STN color liquid crystal, 8 colors, 3M byte built-in memory, compatible with optional OS
High intensity STN color liquid crystal, 8 colors, 3M built-in memory, compatible with optional
OS
A951GOT-QLBD-M3 Monochrome liquid crystal, Monochrome, 3M byte built-in memory, compatible with optional OS
A951GOT-TBD High intensity TFT color liquid crystal, 256 colors,1M byte built-in memory
A951GOT-SBD STN color liquid crystal, 8 colors,1M byte built-in memory
A951GOT-SBD-B High intensity STN color liquid crystal, 8 colors, 1M built-in memory
A951GOT-LBD Monochrome liquid crystal, Monochrome,1M byte built-in memory
High intensity TFT color liquid crystal, 256 colors, 3M byte built-in memory, compatible with
cation interface for A/
CPU)
A951GOT-SBD-M3 STN color liquid crystal, 8 colors, 3M byte built-in memory, compatible with optional OS
High intensity STN color liquid crystal, 8 colors, 3M built-in memory, compatible with optional
OS
A951GOT-LBD-M3 Monochrome liquid crystal, Monochrome, 3M byte built-in memory, compatible with optional OS
A953GOT-TBD High intensity TFT color liquid crystal, 256 colors,1M byte built-in memory
A953GOT-SBD STN color liquid crystal, 8 colors,1M byte built-in memory
A953GOT-SBD-B STN color liquid crystal, 8 colors, 1M built-in memory
A953GOT-LBD Monochrome liquid crystal, Monochrome,1M byte built-in memory
High intensity TFT color liquid crystal, 256 colors,3M byte built-in memory, compatible with
A953GOT-SBD-M3 STN color liquid crystal, 8 colors,3M byte built-in memory, compatible with optional OS
High intensity STN color liquid crystal, 8 colors, 3M built-in memory, compatible with optional
OS
A953GOT-LBD-M3 Monochrome liquid crystal, Monochrome,3M byte built-in memory, compatible with optional OS
A956GOT-TBD TFT color liquid crystal, 256 colors,1M byte built-in memory
A956GOT-SBD STN color liquid crystal, 8 colors,1M byte built-in memory
A956GOT-SBD-B High intensity STN color liquid crystal, 8 colors, 1M built-in memory
A956GOT-LBD Monochrome liquid crystal, Monochrome,1M byte built-in memory
High intensity TFT color liquid crystal, 256 colors,3M byte built-in memory, compatible with
A956GOT-SBD-M3 STN color liquid crystal, 8 colors,3M byte built-in memory, compatible with optional OS
High intensity STN color liquid crystal, 8 colors, 3M built-in memory, compatible with optional
OS
A956GOT-LBD-M3 Monochrome liquid crystal, Monochrome,3M byte built-in memory, compatible with optional OS
A7GT-BUSS For A956GOT, for bus connection, small connector type (For A/QnA/Motion controller CPU)
For A956GOT, for multidrop bus connection, small connector type (For A/QnA/Motion controller
CPU)
Protective sheet A9GT-50PSC Transparent protective sheet for A95 GOT
Backlight A9GT-50LT Backlight for A95 GOT-SBD (-M3), A95 GOT-LBD (-M3)

Debug stand A9GT-50STAND Debug stand for A95 GOT
Attachment A85GT-95ATT For replacement from A85 GOT to A95 GOT
2.3 Component List 2 - 5
Component Type Description

(2) List of Components Available for the A956WGOT
256color, 1M byte Built-in memory (Possible to expand to a maximum of 9M bytes by using a
A9GT-50WQBUSS For bus connection, small connector type (For Q (Q mode) CPU)
A9GT-50WBUSS For bus connection, small connector type (For A/QnA/Motion controller CPU)
For Direct connection to CPU/Computer link connection/Microcomputer connection and RS-
For Direct connection to CPU/Computer link connection/Microcomputer connection and RS-
Protective sheet A9GT-50WPSC Transparent protective sheet for A956WGOT
Debug stand A9GT-50WSTAND Debug stand for A956WGOT
Compact flash card --- Commercially available Compact Flash PC card
A9GT-FNB Exclusively used for optional OS storage
A9GT-FNB1M For optional function OS storage + built-in memory extension, 1M byte
A9GT-FNB2M For optional function OS storage + built-in memory extension, 2M byte
A9GT-FNB4M For optional function OS storage + built-in memory extension, 4M byte
A9GT-FNB8M For optional function OS storage + built-in memory extension, 8M byte
Exclusively used for optional OS storage
(MELSEC-Q Ladder monitor compatible)
For optional function OS storage + built-in memory extension, 4M byte
(MELSEC-Q Ladder monitor compatible)
For optional function OS storage + built-in memory extension, 8M byte
(MELSEC-Q Ladder monitor compatible)

(3) List of Components Available for the A95*GOT/A956WGOT
For A956GOT/A956WGOT, for bus connection, small connector type (For A/QnA/Motion con-
Bus Connection module A9GT-BUSSU
For A956GOT/A956WGOT, for multidrop bus connection, small connector type (For QCPU (Q
For A956GOT/A956WGOT, for multidrop bus connection, small connector type (For A/QnA/
A7GT-J71AP23 For A956GOT/A956WGOT, for MELSECNET(II) optical link connection, for use as local station
For A956GOT/A956WGOT, for MELSECNET(II) coaxial link connection, for use as local sta-
A7GT-J71AT23B For A956GOT/A956WGOT, for MELSECNET/B connection, for use as local station
For A956GOT/A956WGOT, for MELSECNET/10 optical loop network connection, for use as
ordinary station *5
For A956GOT/A956WGOT, for MELSECNET/10 coaxial bus network connection, for use as
ordinary station *5
For A956GOT/A956WGOT, for MELSECNET/10 optical loop network connection, for use as
ordinary station *5
For A956GOT/A956WGOT, for MELSECNET/10 coaxial bus network connection, for use as
ordinary station *5
A8GT-J61BT13 For A956GOT/A956WGOT, for CC-Link connection, for use as intelligent device station
A8GT-J61BT15 For A956GOT/A956WGOT, for CC-Link connection, for use as remote device station
A9GT-J71E71-T For A956GOT/A956WGOT, for Ethernet connection
External I/O module A8GT-50KBF For external I/O equipment connection
Numeric keypad panel A8GT-TK Data entry Numeric Keypad Panel
A1SD59J-MIF For PC card loading
PC card --- SRAM type PC card *6 Refer to the relevant document
Printer interface module A9GT-50PRF For printer connection
Printer compliant with ESC/P24-J84(ESC/P
command compatible) *1
Hewlett Packard printers (PLC command com-
*6 Refer to the relevant document
Bar code reader --- Commercially available bar-code reader
A9GT-QCNB Used for connection of the QCPU (Q mode) long-distance bus.
For conversion from large type connector to small type connector
(Used for connecting the CPU long-distance bus of the A/QnA Motion controller.)
2.3 Component List 2 - 7

QC06B Cable length 0.6m
QC12B Cable length 1.2m
For connection between GOT and QCPU (Q
QC30B Cable length 3.0m
QC50B Cable length 5.0m
For connection between GOT and GOT
QC100B Cable length 10.0m
for QCPU (Q mode)
A9GT-QC150BS Cable length 15.0m
A9GT-QC200BS Cable length 20.0m
For connection between GOT and QCPU (Q
A9GT-QC250BS Cable length 25.0m
A9GT-QC300BS Cable length 30.0m
For connection between GOT and GOT
A9GT-QC350BS Cable length 35.0m
AC06B Cable length 0.6m
AC12B Cable length 1.2m
AC30B Cable length 3.0m
For connection between QnACPU Type/
AC50B Cable length 5.0m
AnCPU Type/motion controller CPU and
AC12B-R Right angle, cable length 1.2m
AC30B-R Right angle, cable length 3.0m
AC50B-R Right angle, cable length 5.0m
A1SC07B Cable length 0.7m For connection between GOT and
A1SC12B Cable length 1.2m
QnASCPU Type/AnSCPU Type/motion con-
A1SC30B Cable length 3.0m
For connection between GOT and GOT
A1SC50B Cable length 5.0m
A8GT-C12NB Cable length 1.2m For connection between QnASCPU Type/
A8GT-C30NB Cable length 3.0m
AnSCPU Type/motion controller CPU and
A8GT-C50NB Cable length 5.0m
A1SC-C05NB Cable length 0.5m
A1SC-C07NB Cable length 0.7m
For connection between GOT and QnACPU
Type/AnCPU Type/motion controller CPU
A1SC-C30NB Cable length 3.0m
A1SC-C50NB Cable length 5.0m
A8GT-C100EXSS Cable length 10.0m For connection between GOT and
A8GT-C200EXSS Cable length 20.0m
QnASCPU Type/AnSCPU Type/motion con-
A8GT-C300EXSS Cable length 30.0m
For connection between GOT and
A8GT-C100EXSS-1 Cable length 10.0m For connection between GOT and
QnASCPU Type/AnSCPU Type/motion con-
A8GT-C200EXSS-1 Cable length 20.0m
For connection between GOT and
A8GT-C300EXSS-1 Cable length 30.0m
A8GT-C100BS Cable length 10.0m
For connection between GOT and GOT A8GT-C200BS Cable length 20.0m
A8GT-C300BS Cable length 30.0m
A370C12B-S1 Cable length 1.2m For connection between GOT and motion
controller CPU A370C25B-S1 Cable length 2.5m
A370C12B Cable length 1.2m For connection between motion controller
CPU and A7GT-CNB A370C25B Cable length 2.5m
For connection between GOT and
A9GT-J2C10B Cable length 1.0m

AC30R4-25P Cable length 3m (D-sub 25-pin at both ends) For connection between GOT and A/
AC100R4-25P Cable length 10m (D-sub 25-pin at both ends)
For connection between GOT and FXCPU
AC300R4-25P Cable length 30m (D-sub 25-pin at both ends)
--- For connection between GOT and computer link module *2
QC30R2 Cable length 3m For connection between GOT and QCPU
For connection between GOT and personal
AC30R2-9P Cable length 3m (D-sub 9-pin, D-sub 25-pin)
computer for data transfer
AC30R2-9SS Cable length 3m (D-sub 9-pin at both ends)
For connection between GOT and personal
RS-232C cable *3
AC30R2 Cable length 3m (D-sub 25-pin at both ends)
computer for data transfer
(9-pin conversion connector required)
AC30N2A Cable length 3m (D-sub 25-pin at both ends)
--- For connection between GOT and computer link module *2
--- For connecting the GOT with the power supply unit of the bar code reader *4
Printer cable *4 AC30PIO-20P Cable length 3m For connection between GOT and printer
Screen creation software for GOT900 series GT Designer 2 ---
*1 The printer of ESC/P raster specifications such as the PM series cannot be connected and used with the GOT.
*2 The RS-422/RS-232C cable for use between GOT and computer link module should be fabricated on the user side
by referring to the [GOT-A900 Series User's Manual (Connection System Manual)].
*3 The RS-232C cable may be fabricated by the user.
The RS-232C cable can also be fabricated by the user.
Refer to the following manual for details of the cable specifications.
*4 The printer cable may be fabricated by the user.
Refer to [A9GT-50PRF type Printer interface module User’s Manual] for full information on the specifications
needed to fabricate the cable.
*5 For the A9GT-QJ71LP23 and A9GT-QJ71BR13, the device range (QCPU, QnACPU, ACPU) that can be monitored
changes depending on the communication driver.
When the A7GT-J71LP23 or A7GT-J71BR13 is mounted, only the device range of the AnA can be monitored.
*6 Relevant document Some devices have been concluded to be applicable for GOT900 series by Mitsubishi.
For details of the devices, refer to the relevant document "List of valid devices applicable for GOT900 series "
(Technical bulletin T10-0028).
Please contact your local Mitsubishi representative for the document, if necessary.
The GOT may not operate correctly if a device other than described in the document is used.
*7 The A8GT-C100EXSS-1, A8GT-C200EXSS-1, and A8GT-C300EXSS-1 are composed of the A8GT-EXCNB (0.5m)
A8GT-C100BS (10m), A8GT-C200BS (20m), and A8GT-C300BS (30m) respectively.
When calculating the cable length, the A8GT-EXCNB‘s cable length can be ignored.
When a GOT is used, a software package of the applicable version or later is required. The versions of the software packages required for each GOT are shown below.
2.4 Software Packages to be Used 2 - 9

SW0D5C-GTWORKS-E Version A or later, SW4D5C-GOTR-
PACKE Version A or later
A950GOT-SBD(-M3) SW0D5C-GTWORKS-E Version A or later, SW1D5C-GOTRE-
PACK Version H or later A950GOT-LBD(-M3)
SW0D5C-GTWORKS-E Version A or later, SW4D5C-GOTR-
PACKE Version A or later
A951GOT-QSBD(-M3) SW0D5C-GTWORKS-E Version A or later, SW3D5C-GOTRE-
PACK Version C or later A951GOT-QLBD(-M3)
SW0D5C-GTWORKS-E Version A or later, SW4D5C-GOTR-
PACKE Version A or later
A951GOT-SBD(-M3) SW0D5C-GTWORKS-E Version A or later, SW1D5C-GOTRE-
SW1D5C-GTWK2-E A or later
PACK Version H or later A951GOT-LBD(-M3)
SW1D5C-GTD2-E A or later
SW0D5C-GTWORKS-E Version A or later, SW4D5C-GOTR-
PACKE Version A or later
A953GOT-SBD(-M3) SW0D5C-GTWORKS-E Version A or later, SW1D5C-GOTRE-
PACK Version H or later A953GOT-LBD(-M3)
SW0D5C-GTWORKS-E Version A or later, SW4D5C-GOTR-
PACKE Version A or later
A956GOT-SBD(-M3) SW0D5C-GTWORKS-E Version A or later, SW1D5C-GOTRE-
PACK Version H or later A956GOT-LBD(-M3)
SW5D5C-GTWORKS-E Version K or later, SW5D5C-GOTR-
PACKE Version K or later
A951GOT-QSBD(-M3)-B
SW1D5C-GTWK2-E Version Q or later
SW5D5C-GTWORKS-E Version Q or later
SW1D5C-GTD2-E Version Q or later
SW5D5C-GOTRE-PACK Version Q or later
A956GOT-SBD(-M3)-B
2.5 Unusable Conventional Products
The following conventional products cannot be used with this GOT.
Bus connection board A9GT-BUSS, A9GT-BUS2S
Bus connection module A7GT-BUS, A9GT-BUS2
Serial communication board A9GT-RS2, A9GT-RS4
Serial communication module A8GT-RS2, A8GT-RS4
Backlight A9GT-70LTT, A9GT-70LTS, A9GT-70LTTB, A9GT-80LTT, A8GT-70LTT, A8GT-70LTS, A8GT-50LT
Ladder monitoring cassette A8GT-MCAM
Extension memory cassette A8GT-MCA1MFDW, A8GT-MCA2MFDW, A8GT-MCA3MFDW
Extension memory board A9GT-FNB, A9GT-FNB1M, A9GT-FNB2M, A9GT-FNB4M
A8GT-70PSCE, A8GT-70PSNE, A8GT-70PSCS, A8GT-70PSNS, A8GT-50PSC, A8GT-50PSN
Printer interface module A8GT-70PRF, A8GT-50PRF
External I/O module A9GT-70KBF, A8GT-70KBF
Debug stand A9GT-80STAND, A9GT-70STAND, A8GT-70STAND, A8GT-50STAND
Option module mounting fixture A8GT-50STE


This section describes the notes on the connecting of the Q4ARCPU with the GOT, as follows:
(1) Notes on the additional base for duplex system at the final stage: To connect the duplex system with the GOT via the bus, connect the GOT with the additional base for duplex system (A68RB) that is provided at the final stage of the duplex system. To use the additional base for duplex system, please apply that of the Version B or after.
(a) The configuration in which the GOT is connected with the fundamental base for the duplex
system (A32RB, A33RB) is connected via the bus.

(b) The configuration in which the GOT is connected with the additional base (A68RB) for duplex
system of Version A is connected via the bus.

2.6 Notes on Q4ARCPU Duplex System 2 - 11

(2) Notes on 5V DC supply for the additional base (A68RB) for duplex system at the final stage: 220mA of current to be consumed will be supplied from the additional base for duplex system at the final stage to the GOT bus interface, if the GOT power supply is off and the power supply for the power supply module mounted on the additional base for duplex system at the final stage is on. Therefore, please make sure that the 5V DC consumption (8A) of the power supply module will not be exceeded by the sum of the value of the current consumption of the input/output module and special function module that are mounted on the additional base for duplex system at the final stage and the value of the current consumption (220mA) of the GOT bus interface.
Power on the GOT-A900 series and Q4ARCPU duplex system in the following order.
(1) Power on the GOT-A900 series. (2) 1 to 2 seconds after power-on of the GOT-A900 series, power on the Q4ARCPU
duplex system.
Power supply of Q4ARCPU duplex system
Power supply of Q4ARCPU duplex system
A61RP
OFF
ON
GOT Power supply of GOT-A900 series
Power supply of GOT-A900 series
It is recommended to switch power on with an external circuit configured.
If power is not switched on in the order as specified in the restriction, the Q4ARCPU duplex system will not start up in system A but will start up in system B before it starts control.

The general specifications of the GOT are indicated below.
Other than display section 0 to 55
temperature -20 to 60
10 to 90 % RH, non-condensing
10 to 90 % RH, non-condensing
Frequency Acceleration Amplitude Sweep Count
10 to 57 Hz --- 0.075 mm
10 times in each
to JIS B3502 and
57 to 150 Hz 9.8 m/s2 ---
of X, Y and Z
10 to 57 Hz --- 0.035 mm
57 to 150 Hz 4.9 m/s2 ---
Shock resistance Conforms to JIS B3502, IEC 61131-2 (147 m/s2, 3 times in each of X, Y and Z directions)
Operating altitude 2000 m(6562 ft) max.
Installation site Inside control box
Overvoltage category *1 II or less
Contamination level *2 2 or less
*1 Indicates the element in the distribution system between the public electricity grid and the mechanical equipment
inside the premises that the relevant device is assumed to be connected to.
Category II applies to devices such as those that draw their power supply from fixed installations.
The surge voltage withstand capability of devices with ratings up to 300V is 2,500V.
*2 This index gives a measure of the incidence of conductive materials in the environment in which the device is used.
A contamination level of 2 indicates an environment in which there is only contamination by non-conducting
materials, but due to occasional condensation, conductivity may occur.
*3 Please do not use or store GOT in an environment with atmospheric pressure greater than the atmospheric
pressure at sea level (0m).
There is a possibility errors may occur if this point is not observed.
3.1 General Specifications 3 - 1

(1) The performance specifications of the A951GOT-Q are shown below.
A951GOT-QSBD
A951GOT-QSBD
A951GOT-QLBD
(-M3)
(-M3)-B
(-M3)
(-M3)
Display section For details of display specifications, refer to Section 3.2 (4)
keys 300 points (15 lines 20 columns)
Key size Minimum 16 16 dots (per key)
Application For monitor screen data storage, for OS storage
Capacity 1M byte built-in (user area) (-M3 has 3M bytes and is compatible with optional OS)
Reference value for data
When installing OS: 640 to 760 seconds (For basic functions, BUS driver and system monitor (approx.
1.3Mbytes))
Interface Built into main unit Bus communication interface for QCPU (Q mode) 1 cannel
Option module interface for option module loading, 1 channel
RS-232C interface For connection of personal computer, for bar-code reader connection, 1 channel
Buzzer output Single tone (tone length adjustable)
Touch key 1 million times or more (operating force 0.98N max.)
Built-in memory Number of write times: 100,000 times
Panel cutting dimensions 156 (6.14) (W) 123.5 (4.86) (H) mm (inch)
Weight 0.71 (1.56) kg(lb) 0.75 (1.65) kg (lb) 0.67 (1.47) kg (lb)
Version 1.17T or later/
Supported from the first
Version 1.17T or later
Supported from the first version (Version 1.00A)
version (Version 1.00A)
Version 2.04E or later/
Version 2.04E or later
Supported from the SW0D5C-GTWORKS-E Version
Version A or later/
A or later/SW3D5C-GOTRE-PACK Version C or
Version A or later
*1 The built-in memory is ROM which allows old data to be overwritten by new data. (Data backup power supply is not
needed.)
*2 When parts must be changed, consult your sales representative.

*3 The environmental protective structure (IP rating) differs depending on the hardware version of GOT.
A951GOT-QTBD(-M3)
A951GOT-QSBD(-M3)-B
A951GOT-QLBD(-M3)
Hardware version A or later ---
Hardware version A or later
(Jul., 2001) or later
(Jul., 2001) or later
3.2 Performance Specifications 3 - 3

(2) The performance specifications of the A950/951/953/956GOT are shown below
A951GOT-TBD(-M3)
A953GOT-TBD(-M3)
A956GOT-TBD(-M3)
A950GOT-SBD(-M3)-B
A951GOT-SBD(-M3)-B
A953GOT-SBD(-M3)-B
A956GOT-SBD(-M3)-B
A950GOT-SBD(-M3)
A951GOT-SBD(-M3)
A953GOT-SBD(-M3)
A956GOT-SBD(-M3)
A950GOT-LBD(-M3)
A951GOT-LBD(-M3)
A953GOT-LBD(-M3)
A956GOT-LBD(-M3)
Display section For details of display specifications, refer to Section 3.2 (4)
keys 300 points (15 lines 20 columns)
Key size Minimum 16 16 dots (per key)
Application For monitor screen data storage, for OS storage
Capacity 1M byte built-in (user area) (-M3 has 3M bytes and is compatible with optional OS)
Reference value for data
(approx. 1.3Mbytes))
Interface Built into main unit
Option module interface for option module loading, 1 channel
RS-232C interface For connection of personal computer, for bar-code reader connection, 1 channel
Buzzer output Single tone (tone length adjustable)
Touch key 1 million times or more (operating force 0.98N max.)
Built-in memory Number of write times: 100,000 times
Panel cutting dimensions 156 (6.14) (W) 123.5 (4.86) (H) mm (inch)
GTD2-E Version 1.17T or later
Supported from the SW2D5C-GTWK2-E Version 2.04E or later/ SW2D5C-
GTD2-E Version 2.04E or later
PACK Version A or later
PACK Version H or later
*1 The ROM which allows old data to be overwritten by new data. (Data backup power supply is not needed.)
*2 When parts must be changed, consult your sales representative.

*3 The environmental protective structure (IP rating) differs depending on the hardware version of GOT.
A950GOT-SBD
A950GOT-SBD
(-M3)
(-M3)
(-M3)-B
A951GOT-TBD
A950GOT-LBD
A953GOT-SBD
A956GOT-SBD
A951GOT-SBD
(-M3)
(-M3)
(-M3)
(-M3)
(-M3)-B
A953GOT-TBD
A951GOT-SBD
A953GOT-LBD
A956GOT-LBD
A953GOT-SBD
(-M3)
(-M3)
(-M3)
(-M3)
(-M3)-B
A956GOT-TBD
A951GOT-LBD
A956GOT-SBD
(-M3)
(-M3)
(-M3)-B
Front section:
Hardware version A or later ---
Panel inside:
Front section:
(Jul., 2001)
(Jul., 2001)
(Jul., 2001)
(Jul., 2001)
Panel inside:
3.2 Performance Specifications 3 - 5

(3) The performance specifications of the A956WGOT are shown below.
Display section For details of display specifications, refer to Section 3.2 (4)
keys 450 points (15 lines 30 columns)
Key size Minimum 16 16 dots (per key), (8 16 only for bottom line)
Application For monitor screen data storage, for OS storage
Capacity 1M byte built-in (user area), max. 8M bytes increasable
(approx. 1.3Mbytes))
Communication board slot *2 For communication board loading, 1 slot
For communication module loading, 1 channel
Option module interface For option module loading, 1 channel
Compact flash card interface For Compact flash PC card loading, 1 channel
Memory board slot For memory board loading, 1 slot
RS-232C interface For connection of personal computer, for bar-code reader connection, 1 channel
Buzzer output Single tone (tone length adjustable)
Touch key 1 million times or more (operating force 0.98N max.)
Built-in memory Number of write times: 100,000 times
Outline dimensions 215 (8.46) (W) 133 (5.24) (H) 70.8 (2.79) (D) mm (inch)
Panel cutting dimensions 205.5 (8.09) (W) 123.5 (4.86) (H) mm (inch)
Weight 1.05 (2.31) kg (lb)
Compatible software package *4 SW5D5C-GTWORKS-E Version K or later, SW5D5C-GOTR-PACKE Version K or later
*1 The built-in FLASH ROM memory allows old data be overwritten by new data. (Data backup power supply is not
needed.)
*2 Note that either of the communication board slot and communication module interface may only be used.
*3 When parts must be changed, consult your sales representative.
*4 GT Works2 and GT Designer2 are compatible, starting with the initial products (Version 1.00A).


Display color 256 colors 8 colors 2 monochrome colors *7 256 colors
Intensity 350cd/m2 350cd/m2 110cd/m2 200cd/m2 300cd/m2
Backlight Cold-cathode tube backlight (Backlight OFF/Screen saving time settings are available.)
Display *5 *6 50,000h (Operating ambient temperature: 25 )
(Time period until the intensity becomes 50%, based on the assumption the
*1 If you run the monitor with A956WGOT, the screen may flicker depending on the type of object/shape fill pattern
This is due to the specifications of the LCD panel and is not a malfunction.
Be sure to check the combination of the type of pattern and color on the machine before using.
For patterns likely to flicker and countermeasures against flickers, refer to the PDF manual stored in the used
drawing software.
*2 Depending on the display color combination, the visibility of the screen may be lower from certain viewpoints.
Before using, check the color combination with the machine installed in the usage environment.
By designating bright colors for the basic color types, you can decrease the chances of this phenomenon occurring.
*3 For A95*GOT-(Q)TBD(-M3), A95*GOT-(Q)SBD(-M3)-B and A956WGOT the backlight needs not be replaced, as
they include a backlight of increased life.
*4 When parts must be changed, consult your sales representative.
*5 The screen saving/back light OFF function of GOT is extended, thus reducing burning prevention of the display
panel and extending longevity of the back light.
*6 Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to
completely avoid this symptom, as the liquid crystal display comprises of a great number of display elements.
Please note that these dots appear due to its characteristic and are not caused by product defect.
*7 A screen created with GT Designer2 is displayed with reversing (white/black) on GOT.
The same display image as a screen created with GT Designer2 can be set for the display on GOT with [Setup] of
the utility.

When setting [Reverse display] to [Yes]: The display is the same as one created with GT Designer2.
When setting [Reverse display] to [No]: The reversed (white/black) display of a screen created with GT Designer2
For how to operate the utility, refer to the GOT-A900 Series Operating Manual (Extended Option Functions
3.2 Performance Specifications 3 - 7

Input power supply voltage 24VDC (+10%, -15%)
Input max. power 12W 16W 22W
Inrush current 40Ap, max. (26.4VDC, max. load)
Permissible instantaneous power failure time 1 ms (19.2VDC or more)
Noise immunity By noise simulator of 500Vp-p noise voltage, 1_s noise width and 25 to 60Hz noise frequency
Dielectric withstand voltage 500VAC for 1 minute across DC external terminals and earth
Insulation resistance 10M or larger by insulation resistance tester
Applicable wire size 0.75 to 2 mm2
Applicable solderless terminal RAV1.25-3, V2-S3.3,V2-N3A, FV2-N3A
(Terminal block terminal screw) 59 to 88 N cm2
Remark When an instantaneous power failure occurs for the time exceeding the permissible instantaneous power failure time in the 24VDC power supply, the GOT may be reset. In such a case, the GOT will automatically return and start communicating.
As the communication between the GOT and PLC is stopped when an instantaneous power failure occurs, some object functions may not be performed normally.
Specifications · Item · Applicable tightening torque

(1) Names of the Parts and Their Settings of the A95 GOT are indicated below.
*1: The shape of the interface section changes depending on the GOT.
No. Name Description
Used to set the extension number for GOT assignment
Extension number setting switch, (A951GOT only)
Used to set the I/O slot number for GOT assignment
I/O slot setting switch (A951GOT only)
For RS-422 communication connection
RS-422 communication interface (A950GOT only)
(D-sub 25-pin female metric screw type)
Bus communication interface for QCPU (Q mode)
For bus connection cable connection (For QCPU (Q mode))
For bus communication cable connection
(For A/QnA/Motion controller CPU)
For RS-232C communication cable connection
(D-sub 9-pin male inch screw type)
For connection of personal computer
For connecting the bar code reader (D-sub 9-pin male inch screw type)

(2) Names of the Parts and Their Settings of the A956WGOT are indicated below.

No. Name Description
Used to set the condition of access to the compact flash PC card when it is loaded during
power-on (Factory-set to OFF)
OFF :Access from GOT to compact flash PC card inhibited
ON :Access from GOT to compact flash PC card enabled
(When a memory card interface unit is used, a compact flash PC card cannot be used. There-
fore, turn this switch OFF.)
Indicates whether the compact flash PC card may be loaded/unloaded or not
OFF :Compact flash PC card may be loaded/unloaded
(When switch 3 is OFF)
ON :Compact flash PC card must not be loaded/unloaded
(When switch 3 is ON)
For connection of personal computer
For connecting the bar code reader
For confirming the extension number of the I/O slot number set with the bus connection board
(If you are not using the A9GT-50WBUSS, it is possible to attach the seal included with the
GOT main unit to cover the hole.)
mation hole


This chapter gives a rough procedure to be performed before starting the operation of the GOT.
For GT Designer:
Refer to GT Works Version / GT Designer Version Operating Manual (Startup Manual) For GT Designer2:
Install GT Designer (2) into personal computer.
Refer to GT Works2 Version / GT Designer2 Version Operating Manual (Startup Introductory Manual)
For GT Designer:
Create monitor screen data.
Refer to GT Designer help function For GT Designer2:
Refer to GT Designer2 Version Reference Manual
Perform wiring to supply power to GOT.
Refer to Section 6.3
Install the memory board (only when necessary)
Refer to Section 6.4
To transfer data through cable To transfer data through Compact Flash PC card/PC card
Connect GOT and personal computer by RS-232C cable.
Load PC card into personal computer.
Install personal computer-installed OS program and monitor screen data into GOT.
Install personal computer-installed OS program and monitor screen data to Compact Flash PC card/PC card.
For GT Designer:
Refer to GT Works Version /GT Designer Version Reference Manual For GT Designer2:
Refer to GT Designer2 Version Operating Manual
Load Compact Flash PC card/PC card into GOT, and install OS program and monitor screen data (copy them to built-in memory).
Load various modules to GOT.
Refer to Chapter 6
Make switch setting of communication unit or communication board.
Refer to GOT-A900 Series User's Manual (Connection System Manual)
Connect cables to GOT and required connectors.
Switch on GOT and connected system.
Start monitoring. (Use various monitoring functions.)
Refer to GOT-A900 Series Operating Manual (Extended Option Functions Manual)


This chapter explains how to handle the GOT main unit and components.
6.1.1 Handling instructions
This section describes the instructions for handling the GOT main unit and components.
Before installing or removing the GOT main unit to or from an enclosure, always turn the GOT power OFF before installing or removing the GOT main unit to or from an enclosure. Not doing so can cause a module failure or malfunction. Before loading or unloading the communication module, communication board, external I/O interface module or memory card interface module to or from the GOT, always turn the GOT power OFF before loading or unloading the communication module, external I/O interface module or memory card interface module to or from the GOT. Not doing so can cause a module failure or malfunction. Before starting wiring, always turn the GOT power OFF before starting wiring. Not doing so may cause an electric shock, product damage or malfunction.
The GOT should be used in the environment given in the general specifications of this user's manual. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration. When mounting the GOT main unit to an enclosure, tighten the mounting screws in the specified torque range. Undertightening can cause a drop, short circuit or malfunction. Overtightening can cause a drop, short circuit or malfunction due to the damage of the screws or module. When loading the communication module to the GOT main unit, fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range. Undertightening can cause a drop, failure or malfunction. Overtightening can cause a drop, failure or malfunction due to the damage of the screws or module. Please make sure to ground FG terminal of the GOT power supply unit by applying Class D Grounding (Class 3 Grounding) Method or higher which is used exclusively for the GOT. Correctly wire the power supply module on the GOT after confirming the rated voltage and terminal arrangement of the product. Not doing so can cause a fire or failure. Exercise care to avoid foreign matter such as chips and wire offcuts entering the module. Not doing so can cause a fire, failure or malfunction.
6.1 GOT Main Unit 6.1.1 Handling instructions 6 - 1

Tighten the terminal screws of the GOT power supply section in the specified torque range. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or module. Plug the bus connection cable by inserting it into the connector of the connected module until it "clicks". After plugging, check that it has been inserted snugly. Not doing so can cause a malfunction due to a contact fault. Plug the communication cable into the connector of the connected module and tighten the mounting and terminal screws in the specified torque range. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or module. Do not touch the conductive and electronic parts of the module directly. Doing so can cause a module malfunction or failure.
(1) Do not drop the module or give it strong impact. Doing so can cause a failure because the display device is made of glass.
(2) Do not remove the printed circuit board of the module from the case. Doing so can cause a failure.
(3) When mounting the main unit to a control box or the like, set the display section as shown below.
the range 60 to 105 degrees.
Enclosure, etc.
(4) Tighten the screws in the following specified range.
Screw Location Tightening Torque Range
Ground terminal screw (M3 screw)
59 to 88N cm Terminal block terminal screw (M3 screw)
Module mounting screw (M4 screw)
Communication board mounting screw (M3 screw)
Communication module mounting screw (M3 screw)
36 to 48N cm
Option module mounting screw (M3 screw)
Case fixing screw (M3 screw)
Memory board mounting screw (M2.6 screw) 25 to 35N cm
RS-232C connector mounting screw (#4-40 UNC (inch screw)) 20 to 28N cm
Bus connection cable connector mounting screw for QCPU
(Q mode) 20N cm
Display section · 60° 105°


(1) Mounting panel cutting dimensions When mounting the GOT on a control box door, user-made mounting base or the like, the door or mounting base must be cut as indicated below.

B
(2) Mounting position When mounting the GOT, the following clearances must be left from the other device.

Plate thickness within 2 to 4mm (0.08 to 0.16inch)
required according to its radius of curvature.

Part B size: Please allow a gap 80mm (3.15inch) or more from the structure and other equipment in
the upper part of the unit to often allow good ventilation. Part C size: When installing devices that generate radiated noise (such as a contactor) or a device
that generate heat near the GOT, always leave a clearance of 100mm (3.94inch) or more to the back and 50mm (1.97inch) or more to the left and right to avoid the effects of the noise and heat.

Depending on the type of the cable to be connected to the GOT main body, longer clearances than those specified above may be required.
When mounting a GOT, be sure to consider the dimensions of the connector and the cable bend radius.

6.1 GOT Main Unit 6.1.2 Installation method 6 - 3
Panel opening

(a) Put the GOT main unit into the panel opening, with its front face first.
(b) Mount the GOT in the following four locations at its top and bottom.

(c) How to mount and fix the mounting fixture is given below.

(3) Mounting method

Completely turn off the externally supplied power used in the system when installing or placing wiring. Not completely turning off all power could result in electric shock, damage to the product.
Be sure to ground the FG terminal and LG terminal of the GOT power supply section to the protective ground conductor. Not doing so could result in electric shock or erroneous operation.
When wiring in the GOT power section, be sure that it is done correctly by checking the product's rated voltage and the terminal layout. Connecting a power supply that is different from the rating or incorrectly wiring the product could result in fire or erroneous operation.
Tighten the terminal screws of the GOT power supply section within the specified torque range. If the terminal screws are loose, it could result in short circuits, erroneous operation or erroneous operation. Tightening the terminal screws too far may cause damages to the screws and/or the module, resulting in fallout, short circuits, or erroneous operation.
Be sure there are no foreign substances such as sawdust or wiring debris inside the GOT main unit.
There are two types of noise: radiated noise, which is transmitted through the air, and conducted noise, which is transmitted through a connection wire. In noise countermeasures, the both two types of noise should be taken into account. As the noise countermeasures, there are the following three methods. (1) Block noise
(a) Keep signal wires away from a possible noise source as power wires or high-
power driving circuits.
(b) Shield signal wires.
(2) Reduce generated noise
(a) Reduce the noise generated from high-power motor drive circuits.
(3) Ground noise without fail
(a) Earth the grounding wire to the ground without fail.
(b) Use a grounding wire as thick and short as possible to ensure low grounding
impedance.
(c) Separate the grounding between power and control systems.

6.1 GOT Main Unit 6.1.3 Wiring method 6 - 5

Power supply wiring diagram

Also, to reduce the voltage drop to the minimum, use the thickest wires possible (0.75 to 2mm2). Use a solderless terminal for M3 screw. Also, be sure to tighten the M3 screw within tightening
Lightening surge absorber connection diagram

(1) Separate the ground of the surge absorber for lightening (E1) from that of the
GOT (E2). (2) Select a surge absorber for lightening whose power supply voltage does no
exceed the maximum allowable circuit voltage even at the time of maximum power supply voltage elevation.


1) Connect the LG and FG terminals of GOT unit power to the ground through the terminal block with one wire. 2) Use FG wires of 28 cm or less for the A8GT-C BS cable. 3) Do not connect the FG grounding wire of A8GT-EXCNB cable. 4) Connect the A8GT-C BS cable's FG wire to FG of the GOT unit power terminal block. 5) Connect the A8GT-C BS cable's FG wire on the PLC side to FG of the PLC power supply module. 6) Connect the LG and FG terminals of the terminal block on the PLC to ground with one wire.
(2) When using A8GT-C BS cable
Connect the A8GT-C BS cable's FG wires on the both sides to the FG terminals on the power terminal block of the both side GOTs.

6.1 GOT Main Unit 6.1.3 Wiring method 6 - 7

Use a dedicated grounding wire as far as possible. (Grounding resistance of 100 or less.) • When a dedicated grounding cannot be performed, use (2) Common Grounding shown below. Also, be sure to take noise countermeasures other than grounding.

(2) Common grounding Good (3) Joint grounding Not allowed
(a) An example of independent grounding

* For control system grounding, apply single-point grounding for one system. Especially for the devices communicating each other, be sure to earth the grounding wire at one point.
(b) An example of common grounding

Use a grounding wire as thick and short as possible.
* Apply single-point grounding for one system.

(c) Recommended terminal shapes


6.1 GOT Main Unit 6.1.3 Wiring method 6 - 9


(1) Use the thickest possible (max. 2 mm2 (14 AWG)) wires for the 100/200 VAC and
24 VDC power cables. Be sure to twist these wires starting at the connection terminals. To prevent a short-circuit should any screws loosen, use solderless terminals with insulation sleeves. (2) When the LG terminals and FG terminals are connected, be sure to ground the
wires. Do not connect the LG terminals and FG terminals to anything other than ground. If LG terminals and FG terminals are connected without grounding the wires, the PLC may be susceptible to noise. In addition, since the LG terminals have potential, the operator may receive an electric shock when touching metal parts.
How to wiring the GOT power supply section is explained below.
Wiring diagram of the A95*GOT Wiring diagram of the A956WGOT




The A950GOT can be used as a handy type, in addition to the conventional installation method.
RS-422 cable to connect the GOT and the computer link unit must be prepared by the user.

6.1 GOT Main Unit 6.1.4 Installation of handy type GOT 6 - 11


Connector which can ground earth line to casing of connector
*1: Separately ground the power wire and signal wire.
*2: Power wire and the signal wire must separated by a separate shield and ground to FG.


The protective sheet is used to protect the operation surface from scratches and contamination which may take place when the touch keys of the GOT display section are operated.


6.2 Protective Sheet 6.2.1 Protective sheet type 6 - 13

The memory board is used to store the optional function OS program (ladder monitoring function, recipe function, speech output function, etc.) and to increase the built-in memory capacity.
The following memory board types are available.

A9GT-FNB1M For optional function OS storage + built-in memory extension, 1M byte
A9GT-FNB2M For optional function OS storage + built-in memory extension, 2M byte
A9GT-FNB4M For optional function OS storage + built-in memory extension, 4M byte
A9GT-FNB8M For optional function OS storage + built-in memory extension, 8M byte
For optional function OS storage + built-in memory extension, 4M byte
For optional function OS storage + built-in memory extension, 8M byte
*1 When using the ladder monitor function, use the A9GT-QFNB (4/8M).
*2 There are restrictions on the ROM_BIOS version of the GOT depending on the hardware version of the memory
board. However, the A956WGOT has no problems since it is installed with supported ROM_BIOS, starting with the
initial product.


The memory card interface module is connected to the GOT when the PC card is used with the GOT. The PC card is used to transfer the OS or monitor screen data or to store data using the alarm history func- tion, recipe function or other object function. Refer to the following manual for details of OS or monitor screen data transfer.
Refer to the following manual for details of the alarm history function and recipe function.

The following memory card interface module type is available.


6.4 Memory Card Interface Module 6.4.1 Memory card interface module type 6 - 15

The PC card usable is any of the PC card having the following specifications (standard) whose operations have been checked by Mitsubishi.
(1) How to check for battery low The GOT checks for a battery low of the memory card loaded. (Only when the memory card access switch is ON)
The battery low checking methods are given below. 1) Using the self-diagnostic function to check When a battery low occurs, the corresponding message appears on the self-diagnostic screen. For the details, refer to the [GOT-A900 Series Operating Manual
(Extended Option Functions Manual)]. 2) Using the alarm list display (system alarm) function to check When a battery low occurs, the error warning message and battery low error code appear on the monitor screen. Refer to the following manual for details.
(2) Battery life For the PC card backup time, refer to the instruction manual attached to the memory card used.
(3) Battery changing For the PC card battery changing method, refer to the instruction manual attached to the memory card used.


The PC card can be loaded/unloaded while power is on. Note that the PC card should be loaded/unloaded after it has been made ready to be loaded/unloaded in the following procedures.


6.4 Memory Card Interface Module 6.4.5 Loading and unloading procedures 6 - 17
(2) Dismounting

The Compact flash PC card is used to transfer the OS and monitor screen data and to store the data of the alarm history and recipe functions. Refer to the following manual for details of OS or monitor screen data transfer.
Refer to the following manual for details of the alarm history function and recipe function.
The Compact flash PC card usable is any of the Compact flash PC card having the following specifications (standard) whose operations have been checked by Mitsubishi.

The Compact flash PC card can be loaded/unloaded while power is on. Note that the Compact flash PC card should be loaded/unloaded after it has been made ready to be loaded/unloaded in the following procedures.
Compact flash card top face.
6.5 Compact flash PC card (A956WGOT only) 6.5.2 Loading and unloading procedures 6 - 19
(1) Mounting · (2) Dismounting · Push

The communication board is used to make the A956WGOT interface compatible with the system to be con- nected to. For the details of the connection form, refer to the [GOT-A900 Series User's Manual (Connection System Manual)].
The following connection board types are available.

A9GT-50WQBUSS For bus connection, small connector type (For QCPU (Q mode))
A9GT-50WBUSS For bus connection, small connector type (For A/QnA/Motion controller CPU)
A9GT-50WRS4 For Direct connection to CPU/Computer link connection/Microcomputer connection and RS-422 connection
A9GT-50WRS2 For Direct connection to CPU/Computer link connection/Microcomputer connection and RS-232C connection



The communication module is used to make the A956GOT, A956WGOT interface compatible with the sys- tem to be connected to. For the details of the connection form, refer to the [GOT-A900 Series User's Manual (Connection System Manual)].
The following connection module types are available.
A9GT-QBUS2SU For multidrop bus connection, small connector type (For QCPU (Q mode))
For bus connection, small connector type (For A/QnA/Motion controller CPU) A7GT-BUSS *1 *2
For multidrop bus connection, small connector type (For A/QnA/Motion controller CPU) A7GT-BUS2S *1 *2
A7GT-J71AP23 For MELSECNET(II) optical link connection, for use as local station
A7GT-J71AR23 For MELSECNET(II) coaxial link connection, for use as local station
A7GT-J71AT23B For MELSECNET/B connection, for use as local station
A9GT-QJ71LP23 For MELSECNET/10 optical loop network connection, for use as ordinary station *3
A9GT-QJ71BR13 For MELSECNET/10 coaxial bus network connection, for use as ordinary station *3
A7GT-J71LP23 For MELSECNET/10 optical loop network connection, for use as ordinary station *3
A7GT-J71BR13 For MELSECNET/10 coaxial bus network connection, for use as ordinary station *3
A8GT-J61BT13 For CC-Link connection, for use as intelligent device station
A8GT-J61BT15 For CC-Link connection, for use as remote device station
A9GT-J71E71-T For Ethernet connection
*1 The A956WGOT cannot be used.
*2 When using the A7GT-BUSS or A7GT-BUS2S, the module hardware version must be version B or above.

Confirm the hardware version of the unit stamped on the rating plate of the product.
*3 For the A9GT-QJ71LP23 and A9GT-QJ71BR13, the device range (QCPU, QnACPU, ACPU) that can be monitored
When the A7GT-J71LP23 or A7GT-J71BR13 is mounted, only the device range of the AnA can be monitored.
For details, refer to the GOT-A900 Series User's Manual (Connection).

6.7 Communication Module (A956GOT, A956WGOT Only) 6.7.1 Connection module types 6 - 21
Type Description



The following software packages are required to use the communication module.
SW0D5C-GTWORKS-E Version A or later
SW3D5C-GOTRE-PACK Version A or later A7GT-BUSS
SW1D5C-GTWK2-E Version A or later
SW1D5C-GTD2-E Version A or later
A9GT-BUS2SU
A7GT-J71AP23
A7GT-J71AR23
SW1D5C-GTWK2-E Version A or later
SW1D5C-GTD2-E Version A or later
SW0D5C-GTWORKS-E Version A or later *1
SW3D5C-GOTRE-PACK Version A or later *1
SW1D5C-GTWK2-E Version A or later *1
SW1D5C-GTD2-E Version A or later *1
SW1D5C-GTWK2-E Version K or later *2
SW1D5C-GTD2-E Version K or later *2
A8GT-J61BT15
SW1D5C-GTWK2-E Version A or later
SW1D5C-GTD2-E Version A or later
SW5D5C-GTWORKS-E Version P or later *3
SW5D5C-GOTRE-PACK Version P or later *3
*1 The device range of the AnA can be monitored.
*2 The device ranges of the QCPU, QnACPU and ACPU can be monitored.
*3 When using the A9GT-J71E71-T whose hardware version is Version E or later, use Version 26C or later. (Cannot be
used for Version P to Version Y.)
6.7 Communication Module (A956GOT, A956WGOT Only) 6.7.2 Mounting procedure 6 - 23

The printer interface module is connected to the GOT when the printer is used with the GOT. The printer is used to print the data and others of the alarm history and hard copy functions. Refer to the following manual for details of the corresponding functions.
The following printer interface module type is available.
A9GT-50PRF Printer interface module

box or the like. (2- 3.5 mounting holes) The A9GT-50PRF's GOT connection cable is 50cm long. Install the A9GT-50PRF within this distance so that the GOT-end connector of the cable may be fitted into the GOT's connector. When mounting the A9GT-50PRF on the back of control box door, exercise care to avoid screw holes passing through the control box surface. 2) Tighten the mounting screw to the specified torque range 39 to 59N cm.
Type Description


The printer usable is any of the printers having the following specifications (standard) whose operations have been checked by Mitsubishi.


6.8 Printer Interface Module 6.8.3 Printer types 6 - 25

The external I/O module is connected with the ten-key panel (A8GT-TK) or keyboard to receive up to 8/64 points of inputs or provide up to 16 points of outputs. Refer to the following manual for details of the corresponding functions.
The following external I/O module is available.
A8GT-50KBF External I/O module

box or the like. (2- 3.5 mounting holes) The A8GT-50KBF's GOT connection cable is 50cm long. Install the A8GT-50KBF within this distance so that the GOT-end connector of the cable may be fitted into the GOT's connector. When mounting the A8GT-50KBF on the back of control box door, exercise care to avoid screw holes passing through the control box surface.

Type Description


The bar code reader is used for writing data that is read with the bar code reader into the programmable con- troller CPU. Refer to the following manual for details of the bar code function.
The bar-code reader, which has been confirmed to operate properly by Mitsubishi Electric, can be used. For the operation-confirmed models, refer to the separately available document "List of operation-confirmed devices for GOT900 series" (Technical bulletin T10-0028). When the document is necessary, please contact your local Mitsubishi representative. If the bar-code reader used is not given in the document, it may not operate properly. The above document can be viewed on the Mitsubishi Electric FA Network Service On World Wide, MEL- FANSweb home page. (MELFANSweb home page: http://wwwf2.MitsubishiElectric.co.jp/melfansweb/english/)

6.10 Bar Code Reader 6.10.1 Bar code reader types 6 - 27
For A95 GOT · For A956WGOT

The debug stand is used to secure the GOT in a standing position so that the monitor screen data may be debugged easily.
The following debug stand type is available.


Adjust at 45 , 55 , 65 or 75


The attachment is used to replace the A85*GOT with the A95*GOT. By the use of the attachment, additional machining to the installation hole in the control panel of the A85*GOT can be eliminated.


6.12 Attachment (A95*GOT only) 6.12.1 Attachment type 6 - 29
Installation panel · Attachment · Installation panel

This chapter explains the items which should be performed daily or periodically to use the GOT to its opti- mum.
The following instructions should be observed for maintenance and inspection.
When power is on, do not touch the terminals. Doing so can cause an electric shock or malfunction. Before starting cleaning or terminal screw retightening, always switch off the power externally in all phases. Not switching the power off in all phases can cause a module failure or malfunction. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or module. Before changing the backlight, always turn the GOT power OFF (When using a GOT bus connection, also turn OFF the PLC CPU power), and remove the GOT main unit from the panel before changing the backlight. Not switching the power off in all phases may cause an electric shock. Not removing the unit from the enclosure can cause injury due to a drop.
Do not disassemble or modify the module. Doing so can cause a failure, malfunction, injury or fire. Do not touch the conductive and electronic parts of the module directly. Doing so can cause a module malfunction or failure. The cables connected to the module must be run in ducts or clamped. Not doing so can cause the module or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault. When unplugging the cable connected to the module, do not hold and pull the cable portion. Doing so can cause the module or cable to be damaged or can cause a malfunction due to a cable connection fault. When disposing of the product, handle it as industrial waste. While changing the backlight, do not touch the circuit boards and electronic parts of the GOT. Doing so can cause a failure or malfunction. When replacing the backlight, use the gloves. Otherwise, it may cause you to be injured. If you should directly touch the plated area of the main unit case with hand, be sure to wipe off the fingerprint and so on, and install the main unit case. Otherwise, it may cause a trouble or malfunction. Start changing the backlight more than 5 minutes after switching the GOT power off. Not doing so can cause a burn due to the heat of the backlight.

Daily inspection items are as follows.
Number Inspection Item Inspection Method Criterion Action
Check for loose mounting
1 Module mounting status
Securely mounted Retighten screws
Retighten screws with screw-
Not loose Retighten terminal screws
Visual check Proper intervals Correct
Visual check Not loose
Inspection items to be checked once or twice in six months or one year are as follows. The following inspection should also be performed when equipment has been moved or modified or the wir- ing changed.
Number Inspection Item Inspection Method Criterion Action
tion 0 to 40
perature Make measurement with ther-
For use in enclosure, tempera-
Other portions 0 to 55
ture inside enclosure is ambi-
Atmosphere No corrosive gas
2 Power supply voltage check
Measure voltage across termi-
20.4DC to 26.4V Change supply power
Looseness Move module Should be mounted firmly Retighten screws
Visual check No dirt, foreign matter sticking Remove, clean
Retighten screws with screw-
Not loose Retighten terminal screws
Visual check Proper intervals Correct
Visual check Not loose
7.2 Daily Inspection 7 - 2

The A95*GOT-TBD(-M3), A95*GOT-SBD(-M3)-B and A956WGOT do not require their backlights to be replaced since they are installed with long-life backlights.
The GOT contains a backlight for the liquid crystal of the display device. The luminance of the back light lowers as it is used. Change the backlight if the screen of the display device has become difficult to look at due to the reduced luminance of the backlight. Change the backlight in the following procedure.

![Page 77 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — [Disposal Instructions]](/cdn/reader/85/85e694f62e1da0fdfe55f930d9d75b233802f08a0203da24a302683139222252/images/page-77.webp?w=400)

When you push the screwdriver into the hole in the unit side, the backlight comes off.
* When changing the backlight, use care not to touch the circuit board in the GOT.
![Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — [Disposal Instructions] diagram (page 77)](/cdn/reader/85/85e694f62e1da0fdfe55f930d9d75b233802f08a0203da24a302683139222252/images/fig-77-2.webp)
To dispose of, please treat the back light as an industrial waste.
![Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — [Disposal Instructions] diagram (page 77)](/cdn/reader/85/85e694f62e1da0fdfe55f930d9d75b233802f08a0203da24a302683139222252/images/fig-77-3.webp)
7.4 How to Change the Backlight for Liquid Crystal 7 - 4

For the products sold in European countries, the conformance to the EMC Directive, which is one of the European Directives, has been a legal obligation since 1996. Also, conformance to the Low Voltage Direc- tive, another European Directives, has been a legal obligation since 1997. Manufacturers who recognize their products must conform to the EMC and Low Voltage Directives required to declare that their products conform to these Directives and put a "CE mark" on their products.
Products that the EMC directive applies to are marked with the CE mark logo.
The EMC Directive specifies that products placed on the market must "be so constructed that they do not cause excessive electromagnetic interference (emissions) and are not unduly affected by electromagnetic interference (immunity)". The applicable products are requested to meet these requirements. The sections 8.1.1 through 8.3.3 sum- marize the precautions on conformance to the EMC Directive of the machinery constructed using the GOT. The details of these precautions has been prepared based on the requirements and the applicable standards control. However, we will not assure that the overall machinery manufactured according to these details con- forms to the above-mentioned directives. The method of conformance to the EMC directive and the judg- ment on whether or not the machinery conforms to the EMC Directive must be determined finally by the manufacturer of the machinery.

Specification Test item Test details Standard value
30M-230MHz QP:
Electromagnetic emissions from the
30dB V/m(30m measurement range) *2, *3
product are measured.
230M-1000MHz QP:
37dB V/m(30m measurement range) *2, *3
Electromagnetic emissions from the
product to the power line are mea-
sured.
Immunity test in which static electric-
ity is applied to the cabinet of the
equipment.
Immunity test in which field is irradi-
Radiated field AM modu-
ated to the product.
80%AM modulation @ 1kHz
Immunity test in which burst noise is
Fast transient burst noise
applied to the power line and signal
(Digital I/O (24V or less)) 250V
lines.
(Analog I/O, signal lines) 250V
Immunity test in which lightening
Power line (between line and ground): 0.5kV
surge is applied to the product.
Immunity test in which a noise
inducted on the power and signal
lines is applied.
Test for checking normal operations
ure and voltage dips
at instantaneous power failure
10ms (interval 1s or more)
Test for checking normal operations
when the power supply unit input
Test for checking if the unit becomes
faulty with a transient voltage of the
internal and external input sides of
the power supply unit or unit power
*1 The GOT is an open type device (device installed to another device) and must be installed in a conductive control
panel. The above test items are conducted in the condition where the GOT is installed on the conductive control
panel and combined with the Mitsubishi PLC.
*3 The above test items are conducted in the following conditions.
30-230MHz QP :40dB þV/m (10m in measurement range)
230-1000MHz QP:47dB þV/m (10m in measurement range)
8.1 Requirements for conformance to EMC Directive 8.1.1 Standards applicable to the EMC directive 8 - 2

The GOT is an open type device (device installed to another device) and must be installed in a conductive control panel or cabinet. It not only assure the safety but also has a large effect to shut down the noise generated from GOT, on the control panel.
(a) Use a conductive control cabinet.
(b) When attaching the control cabinet's top plate or base plate, mask painting and weld so that
good surface contact can be made between the cabinet and plate.
(c) To ensure good electrical contact with the control cabinet, mask the paint on the installation bolts of the inner plate in the control cabinet so that contact between surfaces can be ensured over the widest possible area.
(d) Earth the control cabinet with a thick wire so that a low impedance connection to ground can
be ensured even at high frequencies. (22mm2 wire or thicker is recommended.)
(e) Holes made in the control cabinet must be 10 cm (3.94in.) diameter or less. If the holes are
10cm (3.94in.) or larger, radio frequency noise may be emitted. In addition, because radio waves leak through a clearance between the control panel door and the main unit, reduce the clearance as much as practicable. The leakage of radio waves can be suppressed by the direct application of an EMI gasket on the paint surface. Our tests have been carried out on a panel having the damping characteristics of 37 dB max. and 30 dB mean (measured by 3 m method with 30 to 300 MHz).
(2) Connection of power and ground wires Ground and power supply wires for the GOT must be connected as described below.
(a) Provide an earthing point near the GOT. Earth the power supply's FG terminal (FG: Frame
Ground) with the thickest and shortest wire possible. (The wire length must be 30cm (11.18in.) or shorter.) The FG terminal function is to pass the noise generated in the GOT to the ground, so an impedance that is as low as possible must be ensured. As the wires are used to relieve the noise, the wire itself carries a large noise content and thus short wiring means that the wire is prevented from acting as an antenna.
(1) Control cabinet

(3) Electrical shock prevention In order to such as the operators from electric shocks, the control box must have the following functions :
(a) The control cabinet must be equipped with a lock so that only skilled or qualified personnel.
(b) The control cabinet must be fitted with advice which automatically stops the power supply
when the cabinet is opened.
(4) Dustproof and waterproof features The control box also has the dustproof and waterproof functions. Insufficient dustproof and waterproof features lower the insulation withstand voltage, resulting in insulation destruction. The insulation in our GOT is designed to cope with the pollution level 2, so use in an environment with pollution level 2 or better.
Pollution level 1: An environment where the air is dry and conductive dust does not exist.
Pollution level 2: An environment where conductive dust does not usually exist, but occasional temporary conductivity occurs due to the accumulated dust. Generally, this is the level for inside the control box equivalent a control room or on the floor of a typical factory.
Pollution level 3: An environment where conductive dust exits and conductivity may be generated due to the accumulated dust. An environment for a typical factory floor.
Pollution level 4 : Continuous conductivity may occur due to rain, snow, etc. An outdoor environment.
It is necessary to use the GOT grounding terminal only when it is in the grounded condition. Be sure to ground the grounding for the safety reasons and EMC Directives.
Functional grounding : Improves the noise resistance.
8.1 Requirements for conformance to EMC Directive 8.1.3 Grounding 8 - 4

Connection conditions and models where the EMC directive is applicable are shown below.

Option module*2 Printer interface module External I/O interface module Memory card interface module
Communication cable*1 For A950GOT RS-422 cable For A951GOT Bus connection cable For A953GOT RS-232C cable
Bus connection module CC-Link communication module Ethernet communication module

Option module*2 Printer interface module External I/O interface module Memory card interface module
Communication module*1 Bus connection module CC-Link communication module Ethernet communication module Communication board*1 Bus connection board Serial communication board
Connection cable*1 Bus connection cable CC-Link dedicated cable Twisted pair shielded cable RS-232C cable RS-422 cable
*1 See section 8.2.3 for information about models and hardware versions that are applicable to the EMC directive.
*2 EMC directive is not applicable when using an option module.
(1) For A95*GOT · (2) For A956WGOT


The following table lists the modules compliant with the EMC directive.
: Compliant with EMC directive : Not compliant with EMC directive
(Built-in bus communication interface for Q CPU (Q mode))
*1 Be aware that if using A950GOT after removing the control panel as described in item 6.1.4, it is not applicable to the EMC directive.
If connecting to a PLC not from this company (MELSEC-Q series, MELSEC-QnA series, MELSEC-A series), refer to the manual of the connected device (PLC, microcomputer) for information about the applicability of the EMC directive

8.2 System Configuration when EMC Directive is Applicable 8.2.2 About modules applicable to the EMC directive 8 - 6

Connection conditions where the A95*GOT is applicable to the EMC directive are shown below.
: Not compliant with EMC directive -: Connection impossible
Connection format A950GOT A951GOT-Q A951GOT A953GOT A956GOT A956WGOT
QnA/ACPU - - L(0105) - K(0105) E(0203)
- - - L(0105) - E(0203)
(RS-232C)
L(0105) - - - - E(0203)
(RS-422)
RS-232C - - - L(0105) - E(0203)
RS-422 L(0105) - - - - E(0203)
MELSECNET connection -
Intelligent device - K(0105) E(0203)
Ethernet connection - P(0203) E(0203)
The table indicates the GOT-compatible hardware version for each connection pattern and the compatibility date. Please use the GOT whose hardware version is later than that described.
Year (Last 2 digits of A.D. year)
(1) For A956GOT Be sure to use the communication modules shown below with A956GOT. If communication modules other than those shown below are used, they are not applicable to the EMC directive.
Connection format Communication module
A9GT-BUSS (Hardware version C or later)
A9GT-BUS2S (Hardware version C or later)
Intelligent device A8GT-J61BT13 (Hardware version E or later)
Remote device A8GT-J61BT15 (Hardware version C or later)
Ethernet connection A9GT-J71E71-T (Hardware version C or later)

(2) For A956WGOT Be sure to use the communication boards/communication modules shown below with A956WGOT. If communication modules/communication boards other than those shown below are used, they are not applicable to the EMC directive.

Confirm the hardware version with the products rating plate.
(Products that the EMC directive applies to are marked with the CE mark logo.)
If making the GOT applicable to the EMC directive, be sure to use the cables shown below.
: EMC directive applicable : EMC directive not applicable

To make applicable to the EMC directive, each cable (including user created cables) must be manufactured.
Refer to section 8.3.2 for the cable manufacturing method.
8.2 System Configuration when EMC Directive is Applicable 8.2.5 About the cable used 8 - 8

Connect and wire GOT equipment as instructed below.
If the GOT equipment is configured in a way that differs from the following instructions
then the system will not comply with EMC directives.
(1) With the power wire, be sure to attach the ferrite core (TDK type ZCAT3035-1330) within 90 mm of the GOT terminal module. Lead the power wire and ground wire as shown in Section 8.1.2 (2). Always ground the FG wires.

*1 Wrap the power wire around the ferrite core.

(a) When connecting CC-Link, use the grounding wire of the FG1 terminal on the CC-Link
communication module to connect to the FG terminal of the GOT power section. Use a grounding wire of 300 mm or less.



Use a CE compatible product for 24 V DC external common power source for GOT. The EMC test run by our company was confirmed with the same panel components as the DENSEI-LAMBDA type JWS 50-24 or DLP120-24-1 installed.

8.3 Wiring Precautions the Part which Matches the EMC Directives 8.3.1 Method to connect the power wire and ground wire 8 - 10

Manufacture the cable used with the GOT with the following method. When manufacturing the cable, a ferrite core, cable clamp and cable shielding material are required. The cable clamp used by Mitsubishi Electric for the EMC specification compatibility test is shown below.


Cut the ground wire from the core where it protrudes from both ends of the cable.

(1) Bus Connection · (a) For A8GT-C100/200/300EXSS · (b) For A8GT-C100/200/300BS



The A8GT-C100/200/300EXSS-1 is a combined product of the A8GT-EXCNB and A8GT-C100/200/300BS.

Ground wire (450mm) Connect to FG of the PLC power supply module
Ground wire (280mm) Connect to FG of the GOT main unit power terminal block
8.3 Wiring Precautions the Part which Matches the EMC Directives 8.3.2 Grounding the ground cable 8 - 12

(d) For other Bus Connection cables

*1 The back aluminum foil side of the cable shield material (shield side) should be exposed.



*1 The back aluminum foil side of the cable shield material (shield side) should be exposed. (Refer to Section 8.3.2 (1)

8.3 Wiring Precautions the Part which Matches the EMC Directives 8.3.2 Grounding the ground cable 8 - 14

(3) Computer Link Connection
(a) For RS-232C cable
The user needs to fabricate the RS-232C cable which is used to connect the GOT and Computer link unit side (serial communication, computer link module or PLC CPU with computer link function). The RS-232C cable connection diagram and the connector are as follows. 1) Connection diagram • If D-sub 9-pin is used for the connector of the computer link unit. (A1SJ71QC24(-R2), A1SJ71UC24-R2, A1SJ71C24-R2, A1SCPUC24-R2, A2CCPUC24, QJ71C24(-R2), QJ71CMO)






8.3 Wiring Precautions the Part which Matches the EMC Directives 8.3.2 Grounding the ground cable 8 - 16

(b) For RS-422 cable (AC30/100/300R4-25P, User created cable)
Refer to the GOT-A900 series User’s Manual (Connection System Manual) for information about the cable creation method. • Wrap the cable shield material around the cable, so that the back aluminum foil side (shield side) of the cable shield material is exposed at both ends of the cable.

*1 The back aluminum foil side of the cable shield material (shield side) should be exposed. (Refer to Section 8.3.2 (1)
(4) CC-Link Connection (CC-Link dedicated cable)

(5) Ethernet Connection (Twisted pair shield cable) Peel the sheath (with the length shown below) at both ends of the cable, and expose the shield wire for grounding.

(b))

(6) Other PLC and Microcomputer connection It is necessary for the user to create the cable used to connect GOT with a PLC or a microcomputer from another company (RS-422 cable or RS-232C cable). Refer to the GOT-A900 series User’s Manual (Connection System Manual) for information about the cable creation method.
When connecting GOT to a PLC or microcomputer from another company, configure the system so that the EMC directive specifications from the connection destination are applicable.
The contents shown below are a collection of the contents that should be enforced when made applicable to the EMC directive; however, the final decision to make the device applicable to the EMC directive and how to make it applicable must be made by the manufacturer of the machine device.
(a) For RS-422 cable

*1 The back aluminum foil side of the cable shield material (shield side) should be exposed. (Refer to Section 8.3.2 (1)

8.3 Wiring Precautions the Part which Matches the EMC Directives 8.3.2 Grounding the ground cable 8 - 18

(b) For RS-232C cable


Ground the cable grounding sections and grounding wire to the control panel where the GOT and base unit are grounded.

For the bus connection cable (in the case of A8GT-C100/200/300EXSS, A8GT-C100/200/300EXSS-1, A8GT-C100/200/300BS), RS-232C cable, CC-Link dedicated cable or shielded twisted-pair cable, ground the braided shield to the control box with the cable clamp (AD75CK).
For the any other bus cable or RS-422 cable, ground the shield surface of the cable shield material to the control box with the cable clamp (AD75CK).
(For details of cable clamp installation, refer to the AD75CK Cable Clamp Instruction Manual .)


This chapter explains the error codes and error messages displayed by the alarm list (system alarm) display function of the monitoring functions. The error codes may also be confirmed in the error code storage area of the system information function. Refer to the following manual for details of the alarm list (system alarm) function and system information function.

This section describes the definition of the error codes and error messages displayed on the monitor screen by the alarm list (system alarm) display function and the manuals to refer to.
(1) Display format on the monitor screen Displayed in the user-set position

Error code Error message Time when error occurred (most recent)
(2) Error codes and manuals to refer to

Source of Error Occurrence Error Code Where to Refer To
MNET/B, MNET(II) 200 to 299 [Data Link System Reference Manual of MNET(II), MNET/B] *1
MNET/10 500 to 799 [Network System Reference Manual of MNET/10] *2
CC-Link 800 to 999 [CC-Link System Master Local Module User’s Manual] *3
*1 Take action with reference to the section explaining the link special relay of the (error code) + 9000.
For example, when the error of error code (210) has occurred, 210 + 9000 = 9210 and refer to the explanation of
M9210 and take the corrective action.
*2 Take action with reference to the section explaining the link special relay of the (error code) – 500.
For example, when the error of error code (510) has occurred, 510 - 500 = 10 and refer to the explanation of
SB000A and take the corrective action.
(Since the link special relay is in hexadecimal, replace a decimal by a hexadecimal.)
*3 Take action with reference to the section explaining the link special relay of the (error code) - 800.
For example, when the error of error code (910) has occurred, 910 – 800 = 110 and refer to the explanation of
SB006E and take the corrective action.
(Since the link special relay is in hexadecimal, replace a decimal by a hexadecimal.)
*4 The FXCPU has error codes 100 to 109 and displays the states of M8060 to M8069 with the error codes.
For example, when the error of error code (100) has occurred, refer to the explanation of M8060 and take the cor-
rective action.
9.1 Definition of the Error Codes and Messages Displayed 9 - 1

(1) Error messages displayed before execution of monitoring
Error Message Definition Action
Check communication line.
The cable, installed communication driver or
erly fitted communication module.
communication module is faulty.
Unauthorized combination of OS program ver-
Confirm the versions of the OS programs
Check memory data.
sions installed.
installed.
Check the memory board mounting status and
F-ROM abnormal The memory board is not mounted correctly.
mounting screw tightening status.
(2) Error codes and messages displayed during execution of monitoring The error codes and messages detected by the GOT are indicated below.
Error Message Definition Action
303 Too many monitor points
The number of objects set to the screen to be dis-
played is too many to reserve the work area of the
Reduce the number of objects 304 Too many trigger points specified
The number of objects set to the screen for print-
305 Too many print-out points speci-
out by the hard copy function is too many to
reserve the work area of the system
Screen data has not been downloaded to the built-
306 No monitor data
Download the screen data to the built-in memory
307 No monitor device setting Object monitoring devices not determined Determine object monitoring devices
308 Specified comment not found or
The comment number set for comment display
Create the comment file and download it to the
does not exist or the comment file does not exist
309 Device read error Device data read caused an error Correct device
(1) The specified base screen/window screen
(1) Specify the existing base screen/window
310 Specified monitor data not found
does not exist in the project data. (2) The specified base screen/window screen
screen. (2) Specify the existing base screen/window
is outside the permissible range.
screen.
The alarms in the history has exceeded the largest
311 More than 1024 alarms in alarm
Reduce the alarms in the alarm history
number of points (1024 points) which the alarm
(Remove the history recovered)
history display function can monitor
The collected time exceeded the upper limit when
the following setting had been made for the scat-
312 The collected time has
chart.
tered chart.
scattered chart for "Initialize and continue".
315 Device write error Data write to device caused an error Correct device
Reconsider the data operation formula so that the
316 Operation result value cannot be
The data operation result has exceeded the range
operation result does exceeded the range which
which can be represented by the device type
can be represented by the device type
320 Specified part not found or out-
The part number set for part display does not
Confirm the part number specified for the part dis-
exist.
play in the screen data

Error Message Definition Action
ERROR MESSAGES APPENDICES INDEX
The station number specified as a monitor destina-
321 Unauthorized station number
Confirm the monitor destination station number in
tion does not exist or is not the station to be moni-
specified for monitor device
322 Specified device outside range
The device number to be monitored is outside the
Set the monitored PLC CPU and parameters to set
the device in the monitorable range 323 Specified file register outside
permissible range of the corresponding PLC CPU
324 AD51H-dedicated device used
The AD51H-dedicated device was monitored in the
Incorporate the AD51H into the system or stop
system which does not use the AD51H
monitoring of the AD51H-dedicated device
325 Specified special module not
Check the loading status of the specified special
The specified special module is not loaded
330 PC card capacity short The PC card does not have enough capacity Check the capacity
331 PC card not loaded or memory
The PC card is not loaded or the memory card
card access switch OFF
access switch is OFF
332 Format error The PC card is not formatted Format the PC card
333 PC card write-protected to dis-
The PC card is write-protected Make the PC card write-enabled
334 PC card fault PC card failure Change the PC card
335 PC card battery voltage low The battery voltage of the PC card is low Change the battery of the PC card
340 Printer in error or power off
The printer is faulty or its power is not on
342 The fuse of KBF module was
A fault occurred in the external I/O interface mod-
ply external power.
ule.
nal I/O interface module.
The external I/O interface module is not mounted
343 KBF module status is abnormal
Mount the external I/O interface module properly.
properly.
It has been attempted to display/enter a value that
345 BCD/BIN conversion error
cannot be BCD/BIN converted
The cable used to connect the GOT and personal
350 RS-232C communication error
351 Recipe file abnormal Recipe file data are not normal
352 Recipe file generation error Recipe file generation failed Start GOT after loading PC card
353 Recipe file write disabled Data write to recipe file failed
354 Error during recipe file write Error occurred during recipe file write Do not unload PC card during recipe operation
355 Error during recipe file read Error occurred during recipe file read
9.2 Error Code and Error Message List 9 - 3

Error Message Definition Action
When the file register name is designated and then
the recipe function again.
356 File system error occurred in
the recipe function is operated, an error occurs in
the designated file register.
PLC drive with the GX Developer, and then
operate the recipe function again.
When the file register name is designated and then
ate the recipe function again.
357 The specified drive of PLC is
the recipe function is operated, there is a fault in
the PLC drive.
PLC drive with the GX Developer, and then
operate the recipe function again.
name, and then operate the recipe function
again (If drive 0 was designated, change to a
When the file register name is designated and then
different drive, and then operate the recipe func-
358 File of PLC access failure
the recipe function is operated, the PLC file regis-
tion again).
ter could not be accessed.
tected, and then operate the recipe function
again.
When the file register name is designated and then
359 Processing is from another
Wait until the peripheral devices finish operating,
the recipe function is operated, other peripheral
and then operate the recipe function again.
devices begin processing for the file register.
Reconsider the data operation formula to avoid the
360 Division error due to divisor of 0 Divisor 0 occurred in the data operation formula
Contradiction in magnitude rela-
Upper and lower limit values have been set as
Check the upper and lower limit value setting and
tionship of upper and lower limit
[upper limit lower limit]
correct them to be [upper limit lower limit]
troller load is increased while accessing another
402 Communication time-out Time-out error occurred during communication
station. In this case, move the other station's
data to the local station's programmable logic
controller, and monitor with the local station.
mand.
Check the cable connection status, the communi-
At the time of receive during RS-422/RS-232C
cation board/communication module mounting sta-
403 SIO request status error
communication, any of overrun error, parity bit
tus, the PLC status, and the communication link
error and framing error occurred.
transmission speed.
(1) The station number specified for CC-Link con-
nection (via G4) is other than that of the master/
406 Specified station doesn’t access
Check the station number of the monitor screen
local station.
for out of range
data.
(2) Access was made to the CPU other than the
QCPU.
407 Other network accessed by
Access was made to the other network at the time
Check the network number in the screen data to
of MELSECNET connection (network system)
avoid access to the other network
421 The specification of E71 cannot
The Ethernet module on the PLC side has been
Set the PLC side Ethernet module for write enable.
set for write disable.
The CPU is faulty or communication cannot be
422 It is not communicate between
Check the CPU for any fault using GX Developer
made between the CPU and PLC side Ethernet
the CPU and E71
or like. (Check the buffer memory.)
module.

Error Message Definition Action
ERROR MESSAGES APPENDICES INDEX
Add the station number set as the screen data to
the Ethernet setting of GT Designer/GT Designer
The station number set as the screen data does
423 Information is insufficient in net-
not exist in the Ethernet setting of GT Designer/ GT
(Use the station number of the PLC side Ethernet
Designer 2.
module set in the parameter setting of GX Devel-
oper.)
Check the following data and do not use the same
station number.
The station number set on the utility screen of the
ity screen of the GOT.
GOT is the same as the station number set in the
424 The same bureau is set by GOT
Ethernet setting of GT Designer/GT Designer 2
data.
and monitor data.
(station number of the PLC side Ethernet module)
or the station number set as the screen data.
setting.
(Use the station number of the PLC side Ether-
net module set in the parameter setting of GX
Developer.)
448 Devices outside file register and
Devices specified are outside file register or buffer
Set PLC file registers. Also correct monitor devices
memory range of QnACPU
Check whether the corresponding communication
During monitoring of the other station via
station has been set correctly in the management
MELSECNET/10, a fault occurred in the corre-
station (reconsider the parameters, switch setting,
etc.)
Check for any disconnected cable or improperly fit-
499 CPU communication error Other communication error
9.2 Error Code and Error Message List 9 - 5

(1) About ROM_BIOS ROM_BIOS is available in two types: for large-sized GOTs (A985GOT(-V), A975GOT, A970GOT, A960GOT) and for medium-sized GOTs (A950GOT, A951GOT, A953GOT, A956GOT) and wide- sized GOT (A956WGOT).

Refer to the following manual for the ROM_BIOS installation method.

Check the rating plate on the back of the GOT to confirm the version of ROM_BIOS factory-installed in the GOT.

(2) About the messages displayed
ERROR MESSAGES APPENDICES INDEX
(a) The GOT will display the following messages if you attempt to install ROM_BIOS that is not
compatible with the GOT to be used. Should the following messages appear due to wrong operation you performed, there will be no problems since installation is not executed and ROM_BIOS is not rewritten.

A few seconds later

If the above messages have appeared, hold the above screen in that status and install the standard monitor OS, communication driver and so on.
The following message will also appear when you power on your GOT for the first time.
In this case, the message does not relate to the installation of ROM_BIOS.
Unless you install the standard monitor OS, the following message will appear whenever you start the GOT.
9.3 Precautions for Installation of ROM_BIOS 9 - 7
![Page 104 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — ROM_BIOS setup Ver1. 1. 0 [B]](/cdn/reader/85/85e694f62e1da0fdfe55f930d9d75b233802f08a0203da24a302683139222252/images/page-104.webp?w=400)
(b) The GOT will display the following messages if you attempt to install ROM_BIOS of a version
earlier than the version of ROM_BIOS installed in the GOT. Should the following messages appear due to wrong operation you performed, there will be no problems since installation is not executed and ROM_BIOS is not rewritten.
Don't turn off the power supply Don't push the reset button. ROM_BIOS Not Rewritable. GOT stopped Please install operating system.
If the above messages have appeared, hold the above screen in that status and install the standard monitor OS, communication driver and so on.

ERROR MESSAGES APPENDICES INDEX
If a cause cannot be located by the troubleshooting procedures specified in section 9.2 when the GOT is bus-connected to the PLC CPU, troubleshoot the cause as follows.
(1) How to locate error positions:
(a) Use of peripheral devices
Using the peripheral devices such as GPP, check what type of the error occurs on the PLC CPU and, based on the error message on the PLC CPU and the check points (See item (2) below), check each module and cable for installation and earthing statuses.
Check the timing of errors. 1) An error occurs when the power is turned on or immediately after the PLC is reset: The error may be detected by the initial processing of the PLC CPU. In this case, because the faulty module may not be identified, use only an END instruction for the sequence program and remove the modules one by one until the error does not occur. When the error is eliminated after a specific module has been removed, the module may be causing the error.
(c) Locating the module where an error occurs: Based on the PLC CPU error codes and special resister information (See item (2)), locate a specific module where an error occurs.
By the method stated above, correct the sequence program or replace the faulty module with a new one, and check whether the error occurs. If the error continues to occur, it may have another cause. Referring to section 9.4.2, locate the error position further.
9.4 Troubleshooting in bus connection 9.4.1 Locating error positions 9 - 9
(b) Error timing

(2) Error messages appearing due to faulty ACPU bus connection and measure against errors
Cause and check point
(1) The scanning time exceeds
the calculation congestion monitoring time. (2) The scanning time may be
(1) Use the error history to check whether
simultaneous occurrence errors are present. (2) Refer to the SP module down check
extended by waiting for a response from an SP module that is down, and errors may occur simultaneously.
22 WDT ERR.
points.
The information stored in the cards
of the module installed in the base
Check the faulty module at special resisters
module and the communication
D9116 to D9123.
module of the GOT is different
(1) Check that the module and the cables
from that read at the initial time.
IFY ERR.
are connected correctly. (2) Check that the PLC and the GOT are
(If an error occurs on a module
(vacant) other than that installed in
earthed correctly.
the base module, the mis-opera-
tion may be caused by noise.)
Check the faulty module from the error step.
(1) Check that the module and the cables
When the FROM/TO instruction is
are connected correctly. (2) Replace the faulty module with a new
executed, an imprecise response
is returned from the special func-
one. (3) Check that the PLC and the GOT are
tion module (including the GOT).
earthed correctly.
(1) Check that the module and the cables
are connected correctly. (2) Because a faulty module cannot be
ACPU
ERR.
At the time of initial communica-
located, remove the modules one by one until no CONTROL_BUS ERR. message appears to indicate the module where the error occurs. (Because the modules are removed, SP. UNIT ERR. message may appear. Stop transmitting the FROM/TO instruction to the applicable module.)
At CPU power ON/
tion, an imprecise response is
returned from the special function
module (including the GOT).
Check the faulty module from the error step.
The special function module was
(1) Check that the module and the cables
are connected correctly. (2) Replace the faulty module with a new
accessed during the execution of a
FROM/TO instruction set, but
one. (3) Check that the PLC and the GOT are
there was no response.
earthed correctly.
At the time of initial communica-
(1) Check that the module and the cables
At CPU power ON/
tion, a response is not returned
are connected correctly. (2) Replace the faulty module with a new
from the special function module
(including the GOT).
one. (3) Check that the PLC and the GOT are
earthed correctly. 43 I/O INT
An imprecise interrupt occurs to
ERR.
the PLC CPU.
(1) Check the number of installed modules. (2) Check the number of extension stages
At CPU power ON/
Too many modules are installed
LAY ERR.
(see the PLC CPU specification).
and the I/O slot numbers.
The FROM/TO instruction is exe-
(1) Review the sequence program. (2) Check the number of extension stages
cuted to any module other than the
ERR.
and the I/O slot numbers.
special function module.

(3) Error messages appearing due to faulty Q/QnACPU bus connection and measure against errors
ERROR MESSAGES APPENDICES INDEX
Cause and check point
An imprecise interrupt occurs to the PLC
ERROR.
CPU.
There was no response from the intelli-
At CPU power ON/
gent function module during initial com-
munications stage.
ule is accessed.
intelligent function module is abnormal.
At the time of initial communication, a
At CPU power ON/
(1) Check that the module and the
response is not returned from the special
cables are connected correctly. (2) Replace the faulty module and
function module (including the GOT).
The intelligent function module was
the cables with new ones. (3) Check that the PLC and the GOT
accessed in the program, but there was
are earthed correctly. (4) Check the number of extension
no response.
is executed.
The special function module was
stages and the I/O slot numbers.
accessed during the execution of a
FROM/TO instruction set, but there was
no response.
There was no response from the intelli-
gent function module when the END
instruction is executed.
function module.
(1) Check that the module and the
cables are connected correctly. (2) Because a faulty module cannot
be located, remove the modules one by one until no CONTROL_BUS ERR. message appears to indicate the module where the error occurs. (Because the modules are removed, SP. UNIT ERR. message may appear. Stop transmitting the FROM/TO instruction to the applicable module.)
At the time of initial communication, an
imprecise response is returned from the
At CPU power ON
special function module (including the
ERR.
GOT).
Check the faulty module from the
error step. (1) Check that the module and the
When the FROM/TO instruction is exe-
cuted, an imprecise response is returned
cables are connected correctly. (2) Replace the faulty module with a
from the special function module (includ-
new one. (3) Check that the PLC and the GOT
ing the GOT).
are earthed correctly.
The information stored in the cards of the
module installed in the base module and
Check the faulty module at special
the communication module of the GOT is
resisters SD1400 to SD1431.
different from that read at the initial time.
(1) Check that the module and the
IFY ERR.
(If an error occurs on a module (vacant)
cables are connected correctly. (2) Check that the PLC and the GOT
other than that installed in the base mod-
ule, the mis-operation may be caused by
are earthed correctly.
noise.)
9.4 Troubleshooting in bus connection 9.4.1 Locating error positions 9 - 11

Cause and check point
(1) In the parameter I/O allocation set- tings, an intelligent function module was allocated to a location reserved for an I/O module. Or, the opposite has happened. (2) In the parameter I/O allocation set- tings, a module other than CPU (or noth- ing) was allocated to a location reserved for a CPU module. Or, the opposite has happened. (3) A general-purpose switch was set to the module with no general-purpose switches.
(1) Reset the parameter I/O
allocation according to the status of installation of the intelligent function module. (2) Reset the parameter I/O
allocation according to the status of installation of the CPU module. (3) Reset the general-purpose switch
settings. (4) Check the number of extension
stages and the I/O slot numbers.
(1) Reset the parameter I/O
In parameter I/O allocation settings, a special function module was allocated to a location reserved for an I/O module. Or, the opposite has happened.
allocation setting to conform with the actual status of the special function modules. (2) Check the number of extension
stages and the I/O slot numbers.
(1) Check the number of installed
The modules more than those specified in the PLC CPU specification are installed.
modules. (2) Check the number of extension
stages and the I/O slot numbers.
At the MELSECNET/MINI auto refresh parameter settings, the module allocation that was set is different from the actual module models at the station numbers in the link system.
Reset the parameter MELSECNET/ MINI auto refresh unit module allocation setting so that it conforms to the station number of the module that is actually linked.
2105 There are too many special function mod- ules that can use dedicated instructions allocated (number of modules installed).
Reduce the number of special function modules installed.
SP. UNIT LAY ERR.
At CPU power ON/ At reset
(1) 5 or more QJ71LP21/BR11 have been installed. (2) 5 or more QJ71E71 (-B2) have been installed. (3) Identical network numbers or station numbers exist in the MELSECNET/10 network system.
(1) Keep the number to 4 or fewer. (2) Keep the number to 4 or fewer. (3) Check the network numbers and
station numbers.
(1) Reset the parameter I/O
allocation setting to conform with the actual status of the special function modules. (2) Check the number of extension
2107 Head X/Y set at the parameter I/O alloca- tion settings is also the head X/Y for some other module.
stages and the I/O slot numbers.
(1) Network module A1SJ71LP21,
A1SJ71AR21, or A1SJ71AT2 B dedi- cated for the A2USCPU has been installed. (2) Network module A1SJ71QLP21 or A1SJ71QBR11 dedicated for the Q2AS has been installed. Change the network module to QJ71LP21 or QJ71BR11.
Change network module to QJ71LP21 or QJ71BR11. QCPU
AJ71LP21 or AJ71BR11 for use with the AnUCPU network module has been installed.
Change network module to AJ71QLP21 or AJ71QBR11. QnACPU
The control system and standby system module configurations are different when a redundant system is in the backup mode.
Check the module configuration of the standby system. Q4ARCPU

Cause and check point
ERROR MESSAGES APPENDICES INDEX
The FROM/TO instruction is executed to
any module other than the special func-
(1) Review the sequence program. (2) Replace the faulty module with a
tion module.
2111 The location designated by link direct
new one.
device (J / ) is not a network module.
(1) The location designated by a
special function module dedicated instruction is not a special function module. (2) Alternatively, it is not the relevant
QCPU
Review the sequence program.
ERROR.
special function module.
Read error individual information, then
No special function module data for simu-
check and edit the special function mod-
lation purposes has been set in the simu-
ule simulation data that corresponds to
lation data.
the numerical value there (program
error location).
The location of Q B and QA1S B is
Check the location of the base unit.
improper.
2122 QA1S B is installed to the basic base
Install Q B as the basic base unit.
unit.
(1) Remove the module installed at
65th or later slot. (2) Remove the module installed at
(1) A module is installed at 65th or later
slot. (2) A module is installed at the slot later
the slot later than the number of slots specified with base allocation setting. (3) Remove the module installed at
At CPU power ON/
than the number of slots specified with base allocation setting. (3) A module is installed at the I/O
LAY ERR.
the I/O points later than the 4,096th point. (4) Change the last module to a
points later than the 4,096th point. (4) A module installed at the 4,096th
point occupies later points.
module which does not exceed the 4,096th point.
(1) A module which the QCPU cannot
(1) Install a module which can be
recognize has been installed. (2) There was no response form the
used with the QCPU. (2) Replace the faulty module with a
intelligent function module.
new one.
Program scan time for initial execution
type program goes over the initial execu-
Read the error individual information at
tion WDT time set in the parameter PC
a peripheral device, check the numerical
RAS settings.
ERROR.
value (time) there, and shorten scan
Program scan time goes over the WDT
time if necessary.
value set in the parameter PC RAS set-
tings.
9.4 Troubleshooting in bus connection 9.4.1 Locating error positions 9 - 13

If the function of the PLC cannot be recovered even when the module on which an error occurs is replaced with a new one, the error may be caused by the effect from another module. Disconnect the extension cables and bus connection cables in order from the modules starting from the module located furthest from the operating position in the system, and check for the status of occurrence of the error each time the cables are disconnected until the error does not occur. The module or extension cables/bus-connection cables disconnected immediately before the error does not occur are considered to cause the error. Examples of the ways of further locating error positions are shown below.

Disconnect the bus-connection cable (IN side) from the final stage GOT.
Disconnect the bus-connection cable (OUT side) from the GOT located one stage before the final stage.
If an error does not occur, the final stage GOT may be faulty.
If an error does not occur, the final stage GOT and the bus-connection cable before the final stage may be faulty.
Repeat the examples 1 and 2 above to locate error positions.

ERROR MESSAGES APPENDICES INDEX
An example of troubleshooting the system which is used when an error occurs on the PLC CPU is shown below.
PLC (main base module)
PLC (extension base module)
Check the error code/step appearing on the PLC CPU. (Obtain the status of the error and the location where the error occurs.)
The SP. UNIT DOWN message appears on CPU.
Turn off the power of the GOT. Turn off the power of the PLC CPU.
Replace the faulty CPU with a new one.
Turn on the power of the PLC CPU.
Turn on the power of the GOT.
The error occurs further (not on CPU).
Turn off the power of the GOT. Turn off the power of the PLC CPU.
Disconnect the bus-connection cable from the GOT 2) at IN side
(to further locate the error positions).
Turn on the power of the PLC CPU.
Turn on the power of the GOT.
The error occurs further (not on the GOT 2) (bus interface module).
Turn off the power of the GOT. Turn off the power of the PLC CPU.
Disconnect the bus-connection cable from the GOT 1) at OUT side
(to further locate the error positions).
Turn on the power of the PLC CPU.
Turn on the power of the GOT.
The error will not occur.
The bus-connection cable connecting the GOT 1) to the GOT 2) is judged faulty.
Replace the faulty bus-connection cable with a new one.
9.4 Troubleshooting in bus connection 9.4.3 Specific example of troubleshooting 9 - 15

The following describes the corrective action when the GOT monitoring screen is blank.
The GOT screen is blank
The GOT Power LED is off.
Power on the GOT.
If the screen will come back, this means the screensaver is set.
The screen will come back on by touching the display section.
This function can be set within the GOT utility menu. 1
The bit of "Forces Screen Saver Enable Signal" for GOT may be on.
System information function (system signal 1) is set. Check the bit status.
If bit is on, turn it off. 2
The backlight has reached its maximum life span.
(Compare the backlight life span and
Replace the backlight.
the operating time.)
Possible cause is GOT hardware fault.
Consult your sales representative.
*1 Refer to GOT-A900 Series Operating Manual (Extended _ Option Functions Manual), for utility menu.
*2 Refer to the following manual for details of the forced screen save signal.
When GT Designer is used:Help function of GT Designer
When GT Designer2 is used:GT Designer2 Version Reference Manual




Type code A B C D E F G H I J K L M
Appendix.1 Outline Dimension Drawings APP - 1
Unit (mm (inch)


APP - 2 Appendix.1 Outline Dimension Drawings


(1) When A9GT-50WQBUSS is used

(2) When A9GT-50WBUSS is used

(3) When A9GT-50WRS2/A9GT-50WRS4 is used

Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only) APP - 3

(4) When A9GT-QBUS2SU/A9GT-BUSSU/A9GT-BUS2SU is used

(5) When A7GT-BUSS/A7GT-BUS2S is used

(6) When A9GT-QJ71LP23/A7GT-J71AP23/A7GT-J71LP23 is used

*1 Determined by the optical fiber cable and connector used.
APP - 4 Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only)


*2 Determined by the coaxial cable and connector used.
Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only) APP - 5

(10) When A9GT-J71E71-T is used

*3 The bending radius (R1: guideline value) near the connector should be the cable outline 4 or more.
(11) When A9GT-50PRF is used

(12) When A8GT-50KBF is used

APP - 6 Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only)


*1 The A8GT-C EXSS/C BS cable has a ground cable (1m).
Always connect this ground cable to the control panel or other places.
*2 The A8GT-C EXSS-1 is provided as a set of the A8GT-EXCNB and A8GT-C BS. (Refer to Fig. 8.)
Fig. 1 Fig. 2
33.0 (1.3)
(0.45)
58.0 (2.28)
(0.49)
49.7 (1.96)
49.9 (1.96)
Fig. 3 Fig. 4
60.0 (2.36)
60.0 (2.36) 20.0 (0.79)
20.0 (0.79)
58.0 (2.28)
58.0 (2.28)
Fig. 5 Fig. 6
35.0 (1.38) 33.0 (1.30)
10.0 (0.39)
12.4 (0.49)
42.0 (1.65)
49.9 (1.96)
Fig. 7 Fig. 8

75.0 (2.95)
(0.81)
60.0 (2.36)
Appendix.3 Outline Dimension Drawings of Bus Connection Cables APP - 7

Please confirm the following product warranty details before using this product.
If any faults or defects (hereinafter "Failure") found to be the responsibility of Mitsubishi occurs during use of the product within the gratis warranty term, the product shall be repaired at no cost via the sales representative or Mitsubishi Service Company. However, if repairs are required onsite at domestic or overseas location, expenses to send an engineer will be solely at the customer’s discretion. Mitsubishi shall not be held responsible for any re-commissioning, maintenance, or testing on-site that involves replacement of the failed module. [Gratis Warranty Term]
The gratis warranty term of the product shall be for one year after the date of purchase or delivery to a designated place. Note that after manufacture and shipment from Mitsubishi, the maximum distribution period shall be six (6) months, and the longest gratis warranty term after manufacturing shall be eighteen (18) months. The gratis warranty term of repair parts shall not exceed the gratis warranty term before repairs. [Gratis Warranty Range]
(1) The range shall be limited to normal use within the usage state, usage methods and usage environment, etc.,
which follow the conditions and precautions, etc., given in the instruction manual, user's manual and caution labels on the product. (2) Even within the gratis warranty term, repairs shall be charged for in the following cases.
1. Failure occurring from inappropriate storage or handling, carelessness or negligence by the user. Failure caused by the user's hardware or software design. 2. Failure caused by unapproved modifications, etc., to the product by the user. 3. When the Mitsubishi product is assembled into a user's device, Failure that could have been avoided if functions or structures, judged as necessary in the legal safety measures the user's device is subject to or as necessary by industry standards, had been provided. 4. Failure that could have been avoided if consumable parts (battery, backlight, fuse, etc.) designated in the instruction manual had been correctly serviced or replaced. 5. Failure caused by external irresistible forces such as fires or abnormal voltages, and Failure caused by force majeure such as earthquakes, lightning, wind and water damage. 6. Failure caused by reasons unpredictable by scientific technology standards at time of shipment from Mitsubishi. 7. Any other failure found not to be the responsibility of Mitsubishi or that admitted not to be so by the user. 2. Onerous repair term after discontinuation of production (1) Mitsubishi shall accept onerous product repairs for seven (7) years after production of the product is
discontinued. Discontinuation of production shall be notified with Mitsubishi Technical Bulletins, etc. (2) Product supply (including repair parts) is not available after production is discontinued. 3. Overseas service Overseas, repairs shall be accepted by Mitsubishi's local overseas FA Center. Note that the repair conditions at each FA Center may differ. 4. Exclusion of loss in opportunity and secondary loss from warranty liability Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation of damages caused by any cause found not to be the responsibility of Mitsubishi, loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products, special damages and secondary damages whether foreseeable or not, compensation for accidents, and compensation for damages to products other than Mitsubishi products, replacement by the user, maintenance of on-site equipment, start-up test run and other tasks. 5. Changes in product specifications The specifications given in the catalogs, manuals or technical documents are subject to change without prior notice.
application will not lead to a major accident even if any problem or fault should occur in the programmable logic controller device, and that backup and fail-safe functions are systematically provided outside of the device for any problem or fault. (2) The Mitsubishi programmable logic controller has been designed and manufactured for applications in general
industries, etc. Thus, applications in which the public could be affected such as in nuclear power plants and other power plants operated by respective power companies, and applications in which a special quality assurance system is required, such as for Railway companies or Public service purposes shall be excluded from the programmable logic controller applications. In addition, applications in which human life or property that could be greatly affected, such as in aircraft, medical applications, incineration and fuel devices, manned transportation, equipment for recreation and amusement, and safety devices, shall also be excluded from the programmable logic controller range of applications. However, in certain cases, some applications may be possible, providing the user consults their local Mitsubishi representative outlining the special requirements of the project, and providing that all parties concerned agree to the special circumstances, solely at the users discretion.




What the fault codes shown on the display mean and how to clear them.
| Code | Meaning | Fix | |
|---|---|---|---|
| 303 | Reduce the number of objects | p.98 | |
| 306 | Download the screen data to the built-in memory | p.98 | |
| 307 | Determine object monitoring devices | p.98 | |
| 308 | Create the comment file and download it to the GOT | p.98 | |
| 309 | Correct device | p.98 | |
| 310 | (1) Specify the existing base screen/window screen. (2) Specify the existing base screen/window screen. | p.98 | |
| 311 | Reduce the alarms in the alarm history (Remove the history recovered) | p.98 | |
| 312 | 1. Establish "Clear trigger" set for the scattered chart. 2. Set "Operation at frequency over time" of the scattered chart for "Initialize and continue". | p.98 | |
| 315 | Correct device | p.98 | |
| 316 | Reconsider the data operation formula so that the operation result does exceeded the range which can be represented by the device type | p.98 | |
| 320 | Confirm the part number specified for the part dis- play in the screen data | p.98 | |
| 321 | Confirm the monitor destination station number in the screen data | p.99 | |
| 322 | Set the monitored PLC CPU and parameters to set the device in the monitorable range | p.99 | |
| 324 | Incorporate the AD51H into the system or stop monitoring of the AD51H-dedicated device | p.99 | |
| 325 | Check the loading status of the specified special module | p.99 | |
| 330 | Check the capacity | p.99 | |
| 331 | 1. Load the PC card 2. Turn ON the access switch | p.99 | |
| 332 | Format the PC card | p.99 | |
| 333 | Make the PC card write-enabled | p.99 | |
| 334 | Change the PC card | p.99 | |
| 335 | Change the battery of the PC card | p.99 | |
| 340 | 1. Check the printer 2. The Printer switch it on | p.99 | |
| 342 | 1. If external power (24VDC) is not supplied, sup- ply external power. 2. If external power is supplied, change the exter- nal I/O interface module. | p.99 | |
| 343 | Mount the external I/O interface module properly. | p.99 | |
| 345 | 1. Change the device data to be displayed into a BCD value 2. Enter the value of 4-digit integer | p.99 | |
| 350 | 1. Check for an unplugged communication cable connector 2. check the cables used | p.99 | |
| 351 | 1. Check recipe file data in PC card 2. Start GOT after deleting recipe file in PC card | p.99 | |
| 352 | Start GOT after loading PC card | p.99 | |
| 353 | 1. Check write protect of PC card 2. Check PC card capacity 3. Do not unload PC card during recipe operation | p.99 | |
| 354 | Do not unload PC card during recipe operation | p.99 | |
| 355 | 1. Do not unload PC card during recipe operation 2. Check recipe file data (device values) in PC card | p.99 | |
| 356 | 1. Check the file register name, and then operate the recipe function again. 2. Apply Format PLC memory to the designated PLC drive with the GX Developer, and then operate the recipe function again. | p.100 | |
| 357 | 1. Check the designated PLC drive, and then oper- ate the recipe function again. 2. Apply Format PLC memory to the designated PLC drive with the GX Developer, and then operate the recipe function again. | p.100 | |
| 358 | 1. Check the designated PLC drive/ file register name, and then operate the recipe function again (If drive 0 was designated, change to a different drive, and then operate the recipe func- tion again). 2. Check whether the memory card is write-pro- tected, and then operate the recipe function again. | p.100 | |
| 359 | Wait until the peripheral devices finish operating, and then operate the recipe function again. | p.100 | |
| 360 | Reconsider the data operation formula to avoid the divisor of 0 | p.100 | |
| 370 | Check the upper and lower limit value setting and correct them to be [upper limit lower limit] | p.100 | |
| 402 | 1. Check for any disconnected cable or improperly fitted communication board/communication module 2. This may occur if the programmable logic con- troller load is increased while accessing another station. In this case, move the other station's data to the local station's programmable logic controller, and monitor with the local station. 3. If the sequence scan is long, insert a COM com- mand. | p.100 | |
| 403 | Check the cable connection status, the communi- cation board/communication module mounting sta- tus, the PLC status, and the communication link transmission speed. | p.100 | |
| 406 | Check the station number of the monitor screen data. | p.100 | |
| 407 | Check the network number in the screen data to avoid access to the other network | p.100 | |
| 421 | Set the PLC side Ethernet module for write enable. | p.100 | |
| 422 | Check the CPU for any fault using GX Developer or like. (Check the buffer memory.) | p.100 | |
| 22 | (1) The scanning time exceeds the calculation congestion monitoring time. (2) The scanning time may be extended by waiting for a response from an SP module that is down, and errors may occur simultaneously. | When an End instruction is exe- cuted | p.106 |
| 31 | The information stored in the cards of the module installed in the base module and the communication module of the GOT is different from that read at the initial time. (If an error occurs on a module (vacant) other than that installed in the base module, the mis-opera- tion may be caused by noise.) | When an End instruction is exe- cuted | p.106 |
| 40 | When the FROM/TO instruction is executed, an imprecise response is returned from the special func- tion module (including the GOT). | During execution of FROM/TO instruc- tion set | p.106 |
| 41 | The special function module was accessed during the execution of a FROM/TO instruction set, but there was no response. | During execution of FROM/TO instruc- tion set | p.106 |
| 43 | An imprecise interrupt occurs to the PLC CPU. | During interrupt | p.106 |
| 44 | Too many modules are installed (see the PLC CPU specification). | At CPU power ON/ At reset | p.106 |
| 46 | The FROM/TO instruction is exe- cuted to any module other than the special function module. | During execution of FROM/TO instruc- tion set | p.106 |
| 1310 | An imprecise interrupt occurs to the PLC CPU. | During interrupt | p.107 |
| 1401 | There was no response from the intelli- gent function module during initial com- munications stage. • The size of the buffer memory of the intelligent function module is abnormal. | At CPU power ON/ At reset/When intel- ligent function mod- ule is accessed. | p.107 |
| 1402 | The intelligent function module was accessed in the program, but there was no response. | When an intelligent function module access instruction is executed. | p.107 |
| 1403 | There was no response from the intelli- gent function module when the END instruction is executed. • An error is detected at the intelligent function module. | When an End instruction is exe- cuted | p.107 |
| 1411 | At the time of initial communication, an imprecise response is returned from the special function module (including the GOT). | At CPU power ON | p.107 |
| 1412 | When the FROM/TO instruction is exe- cuted, an imprecise response is returned from the special function module (includ- ing the GOT). | During execution of FROM/TO instruc- tion set | p.107 |
| 2000 | The information stored in the cards of the module installed in the base module and the communication module of the GOT is different from that read at the initial time. (If an error occurs on a module (vacant) other than that installed in the base mod- ule, the mis-operation may be caused by noise.) | When an End instruction is exe- cuted | p.107 |
| 2100 | (1) In the parameter I/O allocation set- tings, an intelligent function module was allocated to a location reserved for an I/O module. Or, the opposite has happened. (2) In the parameter I/O allocation set- tings, a module other than CPU (or noth- ing) was allocated to a location reserved for a CPU module. Or, the opposite has happened. (3) A general-purpose switch was set to the module with no general-purpose switches. | At CPU power ON/ At reset | p.108 |
| 2101 to 2103 | The modules more than those specified in the PLC CPU specification are installed. | p.108 | |
| 2104 | At the MELSECNET/MINI auto refresh parameter settings, the module allocation that was set is different from the actual module models at the station numbers in the link system. | p.108 | |
| 2105 | There are too many special function mod- ules that can use dedicated instructions allocated (number of modules installed). | p.108 | |
| 2106 | (1) 5 or more QJ71LP21/BR11 have been installed. (2) 5 or more QJ71E71 (-B2) have been installed. (3) Identical network numbers or station numbers exist in the MELSECNET/10 network system. | p.108 | |
| 2107 | Head X/Y set at the parameter I/O alloca- tion settings is also the head X/Y for some other module. | p.108 | |
| 2108 | (1) Network module A1SJ71LP21, A1SJ71BR11, A1SJ71AP21 , A1SJ71AR21, or A1SJ71AT2 B dedi- cated for the A2USCPU has been installed. (2) Network module A1SJ71QLP21 or A1SJ71QBR11 dedicated for the Q2AS has been installed. Change the network module to QJ71LP21 or QJ71BR11. | p.108 | |
| 2109 | The control system and standby system module configurations are different when a redundant system is in the backup mode. | p.108 | |
| 2110 | The FROM/TO instruction is executed to any module other than the special func- tion module. | When instruction executed | p.109 |
| 2111 | The location designated by link direct device (J / ) is not a network module. | p.109 | |
| 2112 | (1) The location designated by a special function module dedicated instruction is not a special function module. (2) Alternatively, it is not the relevant special function module. | When instruction executed/ STOP RUN | p.109 |
| 2113 | No special function module data for simu- lation purposes has been set in the simu- lation data. | p.109 | |
| 2120 | The location of Q B and QA1S B is improper. | At CPU power ON/ At reset | p.109 |
| 2122 | QA1S B is installed to the basic base unit. | p.109 | |
| 5000 | Program scan time for initial execution type program goes over the initial execu- tion WDT time set in the parameter PC RAS settings. | Always | p.109 |
| 5001 | Program scan time goes over the WDT value set in the parameter PC RAS set- tings. | p.109 |