SAFETY PRECAUTIONSp.3REVISIONSp.8INTRODUCTIONp.10CONTENTSp.101. ABOUT THE MANUALSp.132. ABBREVIATIONS AND GENERIC TERMS IN THIS MANUALp.143. PACKING LISTp.161 OVERVIEWp.171.1 Featuresp.192 SYSTEM CONFIGURATIONp.212.1 Overall Configurationp.212.2 System Configuration of the GOTp.232.3 Component Listp.232.4 Software Packages to be Usedp.292.5 Unusable Conventional Productsp.302.6 Notes on Q4ARCPU Duplex Systemp.313 PERFORMANCEp.333.1 General Specificationsp.333.2 Performance Specificationsp.343.3 Power Supply Specificationsp.404 NAMES OF THE PARTS AND THEIR SETTINGSp.415 ROUGH PRE-OPERATION PROCEDUREp.436 HANDLINGp.456.1 GOT Main Unitp.456.1.1 Handling instructionsp.456.1.2 Installation methodp.476.1.3 Wiring methodp.496.1.4 Installation of handy type GOTp.556.2 Protective Sheetp.576.2.1 Protective sheet typep.576.2.2 Mounting procedurep.576.3 Memory board (A956WGOT only)p.586.3.1 Memory board typesp.586.3.2 Mounting procedurep.586.4 Memory Card Interface Modulep.596.4.1 Memory card interface module typep.596.4.2 Mounting procedurep.596.4.3 PC card typesp.606.4.4 Battery changing timing and methodp.606.4.5 Loading and unloading proceduresp.616.5 Compact flash PC card (A956WGOT only)p.626.5.1 Compact flash PC card typesp.626.5.2 Loading and unloading proceduresp.636.6 Communication Board (A956WGOT only)p.646.6.1 Communication board typesp.646.6.2 Mounting procedurep.646.7 Communication Module (A956GOT, A956WGOT Only)p.656.7.1 Connection module typesp.656.7.2 Mounting procedurep.666.8 Printer Interface Modulep.686.8.1 Printer interface module typep.686.8.2 How to connect the printer interface modulep.686.8.3 Printer typesp.696.8.4 Connecting procedurep.696.9 External I/O Modulep.706.9.1 External I/O module typep.706.9.2 Mounting procedurep.706.10 Bar Code Readerp.716.10.1 Bar code reader typesp.716.10.2 Connecting procedurep.716.11 Debug Standp.726.11.1 Debug stand typep.726.11.2 Mounting procedurep.726.12 Attachment (A95*GOT only)p.736.12.1 Attachment typep.736.12.2 Mounting procedurep.737 MAINTENANCE AND INSPECTIONp.747.1 Instructions for Maintenance and Inspectionp.747.2 Daily Inspectionp.757.3 Periodic Inspectionp.757.4 How to Change the Backlight for Liquid Crystalp.768 EMC DIRECTIVEp.788.1 Requirements for conformance to EMC Directivep.788.1.1 Standards applicable to the EMC directivep.798.1.2 Control cabinetp.808.1.3 Groundingp.818.2 System Configuration when EMC Directive is Applicablep.828.2.1 Overall configurationp.828.2.2 About modules applicable to the EMC directivep.838.2.3 Connection formatp.848.2.4 When the communication/board module is usedp.848.2.5 About the cable usedp.858.3 Wiring Precautions the Part which Matches the EMC Directivesp.868.3.1 Method to connect the power wire and ground wirep.868.3.2 Grounding the ground cablep.888.3.3 Grounding the cablep.969 ERROR CODES AND ERROR MESSAGESp.979.1 Definition of the Error Codes and Messages Displayedp.979.2 Error Code and Error Message Listp.989.3 Precautions for Installation of ROM_BIOSp.1029.4 Troubleshooting in bus connectionp.1059.4.1 Locating error positionsp.1059.4.2 Further locating error positionsp.1109.4.3 Specific example of troubleshootingp.1119.5 Troubleshooting for monitoringp.112APPENDICESp.113Appendix.1 Outline Dimension Drawingsp.113Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only)p.115Appendix.3 Outline Dimension Drawings of Bus Connection Cablesp.119INDEXp.120Warrantyp.122
Page 1 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual
Page 1 · click to enlarge
Page 1
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) diagram (page 1)
Fig. 1
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) diagram (page 1)
Fig. 2
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) diagram (page 1)
Fig. 3
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) diagram (page 1)
Fig. 4
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) diagram (page 1)
Fig. 5
Page 2 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual
Page 2 · click to enlarge
Page 2
Page 2 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual
Page 3 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A - 1
Page 3 · click to enlarge
Page 3

SAFETY PRECAUTIONS (Always read these instructions before using this equipment.)

Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The instructions given in this manual are concerned with this product. For the safety instructions of the programmable controller system, please read the CPU module user's manual. In this manual, the safety instructions are ranked as "DANGER" and "CAUTION".

Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage. CAUTION

Please save this manual to make it accessible when required and always forward it to the end user. [Design Precautions]

DANGER

Depending on the GOT main unit, communication board, communication module or cable fault, the

output from the GOT interface module may remain ON or may remain OFF. An external monitoring circuit should be provided to check for output signals which may lead to a serious accident. Not doing so can cause an accident due to false output or malfunction.

If a communication fault (including cable disconnection) occurs during monitoring on the GOT,

communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative. For bus connection : The CPU becomes faulty and the GOT inoperative. For other than bus connection : The GOT becomes inoperative. A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur. Not doing so can cause an accident due to false output or malfunction.

Do not use the GOT as the warning device that may cause a serious accident.

An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning. Failure to observe this instruction may result in an accident due to incorrect output or malfunction.

A - 1

Page 4 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A - 2
Page 4 · click to enlarge
Page 4

[Design Precautions]

DANGER

Incorrect operation of the touch switch(s) may lead to a serious accident if the GOT backlight is

gone out. When the GOT backlight goes out, the display section turns black and causes the monitor screen to appear blank, while the input of the touch switch(s) still remains active. This may confuse an operator in thinking that the GOT is in “screensaver” mode, who then tries to release the GOT from this mode by touching the display section, which may cause a touch switch to operate. Note that the following occurs on the GOT when the backlight goes out.

The monitor screen disappears even when the screensaver is not set. The monitor screen will not come back on by touching the display section, even if the screensaver is set.

CAUTION

Do not bundle the control and communication cables with main-circuit, power or other wiring.

Run the above cables separately from such wiring and keep them a minimum of 100mm apart. Not doing so noise can cause a malfunction.

[Mounting Precautions]

DANGER

Before installing or removing the GOT main unit to or from an enclosure, always turn the GOT

power OFF before installing or removing the GOT main unit to or from an enclosure. Not doing so can cause a module failure or malfunction.

Before loading or unloading the communication board, communication module, external I/O

interface module or memory card interface module to or from the GOT, always turn the GOT power OFF before loading or unloading the communication board, communication module, external I/O interface module or memory card interface module to or from the GOT. Not doing so can cause a module failure or malfunction.

CAUTION

The GOT should be used in the environment given in the general specifications of this user's

manual. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.

When mounting the GOT main unit to an enclosure, tighten the mounting screws in the specified

torque range. Undertightening can cause a drop, short circuit or malfunction. Overtightening can cause a drop, short circuit or malfunction due to the damage of the screws or module.

A - 2

Page 5 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A - 3
Page 5 · click to enlarge
Page 5

[Mounting Precautions]

CAUTION

When loading the communication board, External I/O interface module or communication module

to the GOT main unit, fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range. Undertightening can cause a drop, failure or malfunction. Overtightening can cause a drop, failure or malfunction due to the damage of the screws or module.

When loading the communication board to the GOT main unit, take care not to become injured by

the components that are installed or surrounding materials.

When loading the communication board to the GOT main unit, remove any static electricity

accumulated on your body before engaging in work. Otherwise, this may result in damage to the board.

[Wiring Precautions]

DANGER

Before starting wiring, always turn the GOT power OFF before starting wiring.

Not doing so may cause an electric shock, product damage or malfunction.

CAUTION

Please make sure to ground FG terminal of the GOT power supply unit by applying Class D

Grounding (Class 3 Grounding Method) or higher which is used exclusively for the GOT. Not doing so may cause an electric shock or malfunction.

Correctly wire the power supply module on the GOT after confirming the rated voltage and

terminal arrangement of the product. Not doing so can cause a fire or failure.

Tighten the terminal screws of the GOT power supply section in the specified torque range.

Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or module.

Exercise care to avoid foreign matter such as chips and wire offcuts entering the module.

Not doing so can cause a fire, failure or malfunction.

Plug the bus connection cable by inserting it into the connector of the connected module until it

"clicks". After plugging, check that it has been inserted snugly. Not doing so can cause a malfunction due to a contact fault.

Plug the communication cable into the connector of the connected module and tighten the

mounting and terminal screws in the specified torque range. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or module.

A - 3

Page 6 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A - 4
Page 6 · click to enlarge
Page 6

[Test Operation Precautions]

DANGER

Before performing test operation (bit device on/off, word device's present value changing, timer/

counter's set value and present value changing, buffer memory's present value changing) for a user-created monitor screen or system monitoring, read the manual carefully to fully understand how to operate the equipment. During test operation, never change the data of the devices which are used to perform significant operation for the system. False output or malfunction can cause an accident.

[Startup/Maintenance Precautions]

DANGER

When opening the panel on which the GOT is installed, always power off the GOT.

Not doing so can cause the GOT to fail or malfunction.

When power is on, do not touch the terminals.

Doing so can cause an electric shock or malfunction.

Do not change the extension number setting switch and I/O slot setting switch setting during

power-on. Doing so can cause a malfunction.

Before starting cleaning or terminal screw retightening, always turn the power OFF before starting

cleaning or terminal screw retightening. Not switching the power off in all phases can cause a module failure or malfunction. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or module.

When touching the GOT, communication unit, and/or option unit, or before touching the panel with

the GOT installed, touch a grounded metal object to discharge the static electricity from the human body. Failure to do so may cause the unit to fail or malfunction.

CAUTION

Do not disassemble or modify the module.

Doing so can cause a failure, malfunction, injury or fire.

Do not touch the conductive and electronic parts of the module directly.

Doing so can cause a module malfunction or failure.

The cables connected to the module must be run in ducts or clamped.

Not doing so can cause the module or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault.

When unplugging the cable connected to the module, do not hold and pull the cable portion.

Doing so can cause the module or cable to be damaged or can cause a malfunction due to a cable connection fault.

A - 4

Page 7 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A - 5
Page 7 · click to enlarge
Page 7

[Backlight Changing Precautions]

DANGER

Before changing the backlight, always turn the GOT power OFF (when using a GOT bus

connection, also turn OFF the PLC CPU power), and remove the GOT main unit from the panel before changing the backlight. Not switching the power off in all phases may cause an electric shock. Not removing the unit from the enclosure can cause injury due to a drop.

CAUTION

When replacing the backlight, use the gloves.

Otherwise, it may cause you to be injured. If you should directly touch the plated area of the main unit case with hand, be sure to wipe off the fingerprint and so on, and install the main unit case. Otherwise, it may cause a trouble or malfunction.

Start changing the backlight more than 5 minutes after switching the GOT power off.

Not doing so can cause a burn due to the heat of the backlight.

[Disposal Precautions]

CAUTION

When disposing of the product, handle it as industrial waste.

A - 5

Page 8 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A - 6
Page 8 · click to enlarge
Page 8

REVISIONS

The manual number is given on the bottom left of the back cover..

Print Date* Manual NumberRevision Jul., 1999SH (NA)-080018-AFirst edition Mar., 2000SH (NA)-080018-BPartial correction Section 1.1, Chapter 5, Section 6.2, Section 6.3, Section 6.5, Section 6.6, Section 6.7, Section 6.8 Partial addition Section 2.1, Section 2.3, Section 3.1, Section 3.2, Section 3.3, Chapter 4, Section 6.1, Section 6.4, Section 7.4, Appendix 1, Appendix 2, Appendix 3, Index Addition Section 2.2, Section 2.4, Section 6.9, Section 8.4 Addition model Descriptions of A951GOT-QTBD/QSBD/QLBD(-M3) are added. Descriptions of A950/951/953/956GOT-TBD(-M3) are added. Feb., 2001SH (NA)-080018-CPartial correction Section 1.1, Section 2.1, Section 2.2, Section 2.3, Section 2.4, Section 3.1, Section 3.3, Section 4.1, Section 6.1, Section 6.2, Section 6.4, Section 6.7, Section 6.8, Section 6.9, Section 6.10, Section 6.11, Section 6.12, Section 7.4, Section 8.2, Section 8.3, Appendix 1, Appendix 2 Addition Section 6.3, Section 6.5, Section 6.6 Additional model Descriptions of A956WGOT-TBD is added. May, 2001SH (NA)-080018-DPartial correction Section 6.3.1 Partial addition Section 1.1, Section 2.2, Section 2.3, Section 3.2, Section 6.7.1, Section 6.12.2, Section 9.2, Appendix 2 Addition Chapter 8 Feb., 2002SH (NA)-080018-EPartial correction SAFETY PRECAUTIONS Apr., 2002SH (NA)-080018-FPartial correction Section 8.2.2, Section 8.2.3, Section 8.2.5 Partial addition Chapter 4, Section 8.2.1, Section 8.3.1, Section 8.3.2, Section 8.3.3, Section 9.2 Addition Section 8.2.4

A - 6

Page 9 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 1999 MITSUBISHI ELECTRIC CORPORATION
Page 9 · click to enlarge
Page 9
Print Date* Manual NumberRevision Sep., 2004SH (NA)-080018-GMODEL CODE change Changed from 13JL92 to 1DM103. Partial correction Chapter 1, Section 2.1, Section 2.2.2, Section 2.3, Section 2.4, Section 2.5, Section 3.1, Section 3.2, Chapter 4, Chapter 5, Section 6.1.3, Section 6.3.1, Section 6.4.2, Section 6.4.3, Section 6.4.4, Section 6.5, Section 6.8.2, Section 6.9.2, Section 6.10.1, Section 6.10.2, Section 6.12.2, Section 7.4, Section 8.1.1, Section 8.2.2, Section 8.2.4, Section 8.3.2, Section 8.3.3, Section 9.3, Appendix 1, WARRANTY Partial addition Section 3.2, Section 6.7.1, Section 6.7.2, Appendix 2 Addition Section 6.2, Section 6.2.1, Section 6.2.2, Section 6.2.3, Section 6.2.4, Section 6.13 Addition model A95 GOT-SBD(-M3)-B, A95 GOT-QSBD(-M3)-B Dec., 2005SH (NA)-080018-HPartial correction Section 3.2, Section 9.3, Appendix 3 Partial addition Section 9.2 Oct., 2006SH (NA)-080018-IPartial correction SAFETY PRECAUTIONS, Section 2.3, Section 3.2, Section 3.3, Section 8.1.1, Section 8.3.2 Partial addition Section 8.2.5, Section 8.3.1, Section 8.3.2, Section 8.3.3 Nov., 2006SH (NA)-080018-JPartial correction Layouts were revised.

Japanese Manual Version SH-080011-H

This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses.

Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may

occur as a result of using the contents noted in this manual.

1999 MITSUBISHI ELECTRIC CORPORATION

A - 7

Page 10 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — Table of Contents
Page 10 · Contents
Contents

Contents

SAFETY PRECAUTIONSp.3REVISIONSp.8INTRODUCTIONp.10CONTENTSp.101. ABOUT THE MANUALSp.132. ABBREVIATIONS AND GENERIC TERMS IN THIS MANUALp.143. PACKING LISTp.161 OVERVIEWp.171.1 Featuresp.192 SYSTEM CONFIGURATIONp.212.1 Overall Configurationp.212.2 System Configuration of the GOTp.232.3 Component Listp.232.4 Software Packages to be Usedp.292.5 Unusable Conventional Productsp.302.6 Notes on Q4ARCPU Duplex Systemp.313 PERFORMANCEp.333.1 General Specificationsp.333.2 Performance Specificationsp.343.3 Power Supply Specificationsp.404 NAMES OF THE PARTS AND THEIR SETTINGSp.415 ROUGH PRE-OPERATION PROCEDUREp.436 HANDLINGp.456.1 GOT Main Unitp.456.1.1 Handling instructionsp.456.1.2 Installation methodp.476.1.3 Wiring methodp.496.1.4 Installation of handy type GOTp.556.2 Protective Sheetp.576.2.1 Protective sheet typep.576.2.2 Mounting procedurep.576.3 Memory board (A956WGOT only)p.586.3.1 Memory board typesp.586.3.2 Mounting procedurep.586.4 Memory Card Interface Modulep.596.4.1 Memory card interface module typep.596.4.2 Mounting procedurep.596.4.3 PC card typesp.606.4.4 Battery changing timing and methodp.606.4.5 Loading and unloading proceduresp.616.5 Compact flash PC card (A956WGOT only)p.626.5.1 Compact flash PC card typesp.626.5.2 Loading and unloading proceduresp.636.6 Communication Board (A956WGOT only)p.646.6.1 Communication board typesp.646.6.2 Mounting procedurep.646.7 Communication Module (A956GOT, A956WGOT Only)p.656.7.1 Connection module typesp.656.7.2 Mounting procedurep.666.8 Printer Interface Modulep.686.8.1 Printer interface module typep.686.8.2 How to connect the printer interface modulep.686.8.3 Printer typesp.696.8.4 Connecting procedurep.696.9 External I/O Modulep.706.9.1 External I/O module typep.706.9.2 Mounting procedurep.706.10 Bar Code Readerp.716.10.1 Bar code reader typesp.716.10.2 Connecting procedurep.716.11 Debug Standp.726.11.1 Debug stand typep.726.11.2 Mounting procedurep.726.12 Attachment (A95*GOT only)p.736.12.1 Attachment typep.736.12.2 Mounting procedurep.737 MAINTENANCE AND INSPECTIONp.747.1 Instructions for Maintenance and Inspectionp.747.2 Daily Inspectionp.757.3 Periodic Inspectionp.757.4 How to Change the Backlight for Liquid Crystalp.768 EMC DIRECTIVEp.788.1 Requirements for conformance to EMC Directivep.788.1.1 Standards applicable to the EMC directivep.798.1.2 Control cabinetp.808.1.3 Groundingp.818.2 System Configuration when EMC Directive is Applicablep.828.2.1 Overall configurationp.828.2.2 About modules applicable to the EMC directivep.838.2.3 Connection formatp.848.2.4 When the communication/board module is usedp.848.2.5 About the cable usedp.858.3 Wiring Precautions the Part which Matches the EMC Directivesp.868.3.1 Method to connect the power wire and ground wirep.868.3.2 Grounding the ground cablep.888.3.3 Grounding the cablep.969 ERROR CODES AND ERROR MESSAGESp.979.1 Definition of the Error Codes and Messages Displayedp.979.2 Error Code and Error Message Listp.989.3 Precautions for Installation of ROM_BIOSp.1029.4 Troubleshooting in bus connectionp.1059.4.1 Locating error positionsp.1059.4.2 Further locating error positionsp.1109.4.3 Specific example of troubleshootingp.1119.5 Troubleshooting for monitoringp.112APPENDICESp.113Appendix.1 Outline Dimension Drawingsp.113Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only)p.115Appendix.3 Outline Dimension Drawings of Bus Connection Cablesp.119INDEXp.120Warrantyp.122
Page 13 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A - 11
Page 13 · click to enlarge
Page 13

1. ABOUT THE MANUALS

For details of the manuals relevant to this product, refer to the PDF manual stored within the drawing software used.

A - 11

Page 14 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A - 12
Page 14 · click to enlarge
Page 14
2. ABBREVIATIONS AND GENERIC TERMS IN THIS MANUAL Abbreviations and generic terms used in this manual are described as follows:

Abbreviations and generic terms Description

A950GOT Generic term of A950GOT-TBD, A950GOT-SBD, A950GOT-SBD-B, A950GOT-LBD, A950GOT-TBD-M3, A950GOT-SBD-M3, A950GOT-SBD-M3-B and A950GOT-LBD-M3

A951GOT Generic term of A951GOT-TBD, A951GOT-SBD, A951GOT-SBD-B, A951GOT-LBD, A951GOT-TBD-M3, A951GOT-SBD-M3, A951GOT-SBD-M3-B and A951GOT-LBD-M3

A951GOT-Q Generic term of A951GOT-QTBD, A951GOT-QSBD, A951GOT-QSBD-B, A951GOT-QLBD, A951GOT-QTBD-M3, A951GOT-QSBD-M3, A951GOT-QSBD-M3-B and A951GOT-QLBD-M3

GOT

A953GOT Generic term of A953GOT-TBD, A953GOT-SBD, A953GOT-SBD-B A953GOT-LBD, A953GOT-TBD-M3, A953GOT-SBD-M3, A953GOT-SBD-M3-B and A953GOT-LBD-M3

A956GOT Generic term of A956GOT-TBD, A956GOT-SBD, A956GOT-SBD-B, A956GOT-LBD, A956GOT-TBD-M3, A956GOT-SBD-M3, A956GOT-SBD-M3-B and A956GOT-LBD-M3 A95* GOT Generic term of A956GOT, A953GOT, A951GOT, A951GOT-Q and A950GOT A956WGOT Abbreviation of A956WGOT-TBD

Bus connection board Generic term of A9GT-50WQBUSS and A9GT-50WBUSS

Serial communica- tion board Generic term of A9GT-50WRS4 and A9GT-50WRS2

Bus connection unit Generic term of A9GT-QBUS2SU, A9GT-BUSSU, A9GT-BUS2SU, A7GT-BUSS and A7GT-BUS2S Data link unit Generic term of A7GT-J71AP23, A7GT-J71AR23 and A7GT-J71AT23B Network unit Generic term of A9GT-QJ71LP23, A9GT-QJ71BR13, A7GT-J71LP23 and A7GT-J71BR13 CC-Link communi- cation unit Generic term of A8GT-J61BT13 and A8GT-J61BT15

Ethernet communi- cation unit Abbreviation of A9GT-J71E71-T

External I/O unit Abbreviation of A8GT-50KBF type external I/O interface unit Printer interface unit Abbreviation of A9GT-50PRF type Printer interface unit

Memory card inter- face unit Abbreviation of A1SD59J-MIF type Memory card interface unit

Backlight Abbreviation of A9GT-50LT type backlight Debug stand Abbreviation of A9GT-50STAND and A9GT-50WSTAND type debug stand

Memory board Abbreviation of A9GT-FNB, A9GT-FNB1M, A9GT-FNB2M, A9GT-FNB4M, A9GT-FNB8M, A9GT- QFNB, A9GT-QFNB4M, A9GT-QFNB8M type option function memory board Ten-key Panel Abbreviation of A8GT-TK ten-key Panel A7GT-CNB Abbreviation of A7GT-CNB bus connector conversion box A9GT-QCNB Abbreviation of A9GT-QCNB bus connector conversion box Protection sheet Abbreviation of A9GT-50PSC and A9GT-50WPSC type transparent protection sheets PC card (memory card) Generic term of flash PC card, commercially available flash PC card and SRAM PC card

Compact flash PC card Abbreviation of commercially available compact flash PC card

Attachment Abbreviation of A85GT-95ATT attachment

GT Works Version 5 Abbreviation of SW5D5C-GTWORKS-E(-V) software GT Designer Ver- sion 5 Abbreviation of SW5D5C-GOTR-PACKE(V) software

GT Works2 Version1 Abbreviation of SW1D5C-GTWK2-E software

GT Designer2 Version1 Abbreviation of SW1D5C-GTD2-E software

GT Designer Abbreviation of image creation software GT Designer for GOT900 GT Designer2 Abbreviation of image creation software GT Designer2 for GOT900 GT Simulator Abbreviation of GT Simulator screen simulator GOT900 GT Simulator2 Abbreviation of GT Simulator2 screen simulator GOT900 GT Converter Abbreviation of data conversion software GT Converter for GOT900 GT Debugger Abbreviation of debugging software GT Debugger GT Manager Abbreviation of GT Manager data editing software for GOT900 GT SoftGOT Abbreviation of GT SoftGOT monitoring software GT SoftGOT2 Abbreviation of GT SoftGOT2 monitoring software GX Developer Generic term of SW D5C-GPPW-E/SW D5F-GPPW-E software packages

GX Simulator Generic term of SW D5C-LLT-E ladder logic test tool function software package (SW5D5C-LLT-E or later) Acrobat Reader Abbreviation of Adobe Acrobat Reader

A - 12

Show 5 more labels / short text on this page
Communica- tion board · Communica- tion unit · Option unit · Option · Software
Page 15 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A - 13
Page 15 · click to enlarge
Page 15

Abbreviations and generic terms Description

QCPU (Q Mode) Generic term of Q00JCPU, Q00CPU, Q01CPU,Q02CPU, Q02HCPU, Q06HCPU, Q12HCPU, Q25HCPU, Q12PHCPU and Q25PHCPU CPU QCPU (A Mode) Generic term of Q02CPU-A, Q02HCPU-A and Q06HCPU-A CPU

Remote I/O station Network module for MELSECNET/H network system remote I/O station (QJ72LP25-25, QJ72LP25G, QJ72BR15) QCPU Generic term of QCPU (Q Mode) and QCPU (A Mode)

QnACPU Type Generic term of Q2ACPU, Q2ACPU-S1, Q2AHCPU, Q2AHCPU-S1, Q3ACPU, Q4ACPU and Q4ARCPU CPU QnASCPU Type Generic term of Q2ASCPU, Q2ASCPU-S1, Q2ASHCPU and Q2ASHCPU-S1 CPU QnACPU Generic term of QnACPU Type and QnASCPU Type AnUCPU Generic term of A2UCPU, A2UCPU-S1, A3UCPU and A4UCPU CPU AnACPU Generic term of A2ACPU, A2ACPU-S1 and A3ACPU CPU AnNCPU Generic term of A1NCPU, A2NCPU, A2NCPU-S1 and A3NCPU CPU AnCPU Type Generic term of AnUCPU, AnACPU and AnNCPU CPU AnUS(H)CPU Generic term of A2USCPU, A2USCPU-S1 and A2USHCPU-S1 CPU

CPU

AnS(H)CPU Generic term of A1SCPU, A1SCPUC24-R2, A2SCPU, A2SCPU-S1, A1SHCPU, A2SHCPU and A2SHCPU-S1 CPU A1SJ(H)CPU Generic term of A1SJCPU, A1SJCPU-S3 and A1SJHCPU CPU AnSCPU Type Generic term of A2US(H)CPU, AnS(H)CPU and A1SJ(H)CPU CPU

ACPU Generic term of AnCPU Type, AnSCPU Type, A1FXCPU, A0J2HCPU, A2CCPU, A2CCPU24 and A2CJCPU CPU

FXCPU Generic term of FX0 series, FX0N series, FX0S series, FX1 series, FX1N series, FX1S series, FX2 series, FX2C series, FX2N series, FXINS series, FX2NC and FX3UC series CPU

Generic term of A273UCPU, A273UHCPU, A273UHCPU-S3, A373CPU, A373UCPU, A373UCPU- S3, A171SCPU, A171SCPU-S3, A171SCPU-S3N, A171SHCPU, A171SHCPUN, A172SHCPU, A172SHCPUN, A173UHCPU, A173UHCPU-S1, Q172CPU, Q173CPU, Q172CPUN, Q173CPUN CPU FA controller Generic term of LM610, LM7600, LM8000 CPU Peripheral connec- tion mod- ule

G4 Abbreviation of AJ65BT-G4-S3

E71 Generic term of AJ71E71-S3, A1SJ71E71-B2-S3, A1SJ71E71-B5-S3, AJ71E71N-B2, AJ71E71N- B5T, A1SJ71E71N-B2 and A1SJ71E71N-B5T

Generic term of AJ71QE71, A1S 1-B2, AJ71QE71-B5, A1SJ71QE71-B5, AJ71QE71N-B2, AJ71QE71N-B5T, A1SJ71QE71N-B2 and A1SJ71QE71N-B5T Q series-compatible E71 Generic term of QJ71E71, QJ71E71-B2 and QJ71E71-100

QE71

Generic term of C200HS, C200H, C200H series(C200HX, C200HG, C200HE), CQM1, C1000H,C2000H,CV500, CV1000, CV2000, CVM1-CPU11, CVM1-CPU21, CS1, CS1D, CJ1M, CPM1, CPM1A, CPM2A, CPM2C CPU, CQM1H

Yaskawa PLC Generic term of GL60S, GL60H, GL70H, GL120, GL130, CP-9200SH, CP-9300MS, MP-920, MP- 930, MP-940, CP-9200(H) and PROGIC-8 CPU

SLC500 Series Generic term of SLC500-20, SLC500-30, SLC500-40, SLC5/01 SLC5/02, SLC5/03, SLC5/04 SLC5/ 05

Generic term of 1761-L10BWA, 1761-L10BWB, 1761-L16AWA, 1761-L16BWA, 1761-L16BWB, 1761-L16BBB, 1761-L32AWA, 1761-L32BWA, 1761-L32BWB, 1761-L32BBB, 1761-L32AAA, 1761- L20AWA-5A, 1761-L20BWA-5A, 1761-L20BWB-5A MicroLogix1500 Series Abbreviation of 1764-LSP Allen-Bradley PLC Generic term of SLC 500 Series, MicroLogix1000 Series, MicroLogix1500 Series

Sharp PLC Generic term of JW-21CU, JW-22CU, JW-31CUH, JW-32CUH, JW-33CUH, JW-50CUH, JW-70CUH, JW-100CUH, JW-100CU, Z-512J CPU PROSEC T Series Generic term of T2(PU224 type), T2E, T2N, T3, T3H CPU PROSEC V Series Generic term of S2T, Model3000(S3) CPU Toshiba PLC Generic term of PROSEC T Series and PROSEC V Series SIEMENS PLC Generic term of SIMATIC S7-300 Series and SIMATIC S7-400 Series CPU

Large type H series Generic term of H-302(CPU2-03H), H-702(CPU2-07H), H-1002(CPU2-10H), H-2002(CPU2-20H), H- 4010(CPU3-40H),.J-300(CPU-03Ha), H-700(CPU-07Ha), H-2000(CPU-20Ha)

H200 to 252 Series Generic term of H-200(CPU-02H, CPE-02H), H-250(CPU21-02H), H-252(CPU22-02H), H- 252B(CPU22-02HB), H-252C(CPU22-02HC, CPE22-02HC)

H Series board type Generic term of H-20DR, H-28DR, H-40DR, H-64DR, H-20DT, H-28DT, H-40DT, H-64DT, HL-40DR, HL-64DR EH-150 Series Generic term of EH-CPU104, EH-CPU208, EH-CPU308, EH-CPU316 HITACHI PLC (HIDIC H Series) Generic term of large type H series, H-200 to 252 Series H Series board type, EH-150 Series

Matsushita Electric Works PLC

Generic term of FP0-C16CT, FP0-C32CT, FP1-C24C, FP1-C40C, FP2, FP2SH, FP3, FP5, FP10(S), FP10SH, FP-M(C20TC) and FP-M(C32TC)

Memory abbreviation of memory (flash memory) in the GOT OS Abbreviation of GOT system software Object Setting data for dynamic image Personal Computer Personal computer where the corresponding software package is installed Servo amplifier Generic term of the MR-J2S- A, MR-J2S- CP and MR-J2M A series MELDAS C6/C64 Generic term of the FCA C6, FCA C64

A - 13

Show 6 more labels / short text on this page
Motion controller CPU · Ethernet module · Omron PLC · MicroLogix1000 Series · Other PLC · Others
Page 16 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A - 14
Page 16 · click to enlarge
Page 16

3. PACKING LIST

After unpacking, confirm that you have received the following products.

GOT main unit 1

* For use when closing the bus connec-

tion board setting switch confirmation

hole.

A950GOT-TBD(-M3)/SBD(-M3)/SBD(-M3)-B/LBD(-M3),

A951GOT-QTBD(-M3)/QSBD(-M3)/QSBD(-M3)-B/QLBD(-M3),

A951GOT-TBD(-M3)/SBD(-M3)/SBD(-M3)-B/LBD(-M3),

A953GOT-TBD(-M3)/SBD(-M3)/SBD(-M3)-B/LBD(-M3),

A956GOT-TBD(-M3)/SBD(-M3)/SBD(-M3)-B/LBD(-M3) User's Manual (Hardware) *

A956WGOT-TBD User's Manual (Hardware) *

* Changes with the GOT you purchased.

A - 14

Show 6 more labels / short text on this page
Product Quantity · Mounting fixture 4 · Communication · module securing fixture · (A956GOT, A956WGOT only) · Seal (A956WGOT only)
Page 17 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A951GOT-QLBD-M3
Page 17 · click to enlarge
Page 17

This user's manual explains the specifications, handling and other information of the A950GOT/A951GOT/ A953GOT/A956GOT/A956WGOT graphic operation terminal module (abbreviated to the GOT).

The GOT can be used as an electronic operator panel which has achieved on its monitor screen the switch operation, lamp indication, data display, message display and other operations which were previously per- formed on an operator panel.

The following GOT types are available.

Interface built into main unit Display section

A950GOT-TBD

A950GOT-SBD

A950GOT-SBD-B

A950GOT-LBD

A950GOT-TBD-M3

A950GOT-SBD-M3

A950GOT-SBD-M3-B

A950GOT-LBD-M3

A951GOT-QTBD

TBD(-M3)High-intensity TFT

A951GOT-QSBD

A951GOT-QSBD-B

TBD(-M3): 256

A951GOT-QLBD

SBD(-M3)-BHigh-intensity

SBD(-M3), SBD(-

STN color liquid crystal

24VDC

A951GOT-QTBD-M3

M3)-B: 8

(For QCPU (Q Mode))

SBD(-M3)STN color

LBD(-M3): 2

A951GOT-QSBD-M3

A951GOT-QSBD-M3-B

LBD(-M3)Monochrome

A951GOT-QLBD-M3

A951GOT-TBD

A951GOT-SBD

A951GOT-SBD-B

A951GOT-LBD

A951GOT-TBD-M3

A951GOT-SBD-M3

A951GOT-SBD-M3-B

A951GOT-LBD-M3

Show 21 more labels / short text on this page
Rough Specifications · Type · Screen size · Display color · Power · [cm (inch)] · [color] · Supply type · Built-in RS-422 · communication interface · color · liquid crystal · Built-in bus · 15 (6) · communication interface · liquid crystal · liquid crystal · Built-in bus · communication interface · (For A/QnA/Motion control- · ler CPU)
Page 18 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A956GOT-TBD-M3
Page 18 · click to enlarge
Page 18

The following GOT types are available.

Interface built into main unit Display section

A953GOT-TBD

A953GOT-SBD

A953GOT-SBD-B

A953GOT-LBD

A953GOT-TBD-M3

A953GOT-SBD-M3

TBD(-M3)High-intensity TFT

A953GOT-SBD-M3-B

A953GOT-LBD-M3

TBD(-M3): 256

SBD(-M3)-BHigh-intensity

A956GOT-TBD

SBD(-M3), SBD(-

STN color liquid crystal

24VDC

A956GOT-SBD

M3)-B: 8

SBD(-M3)STN color

LBD(-M3): 2

A956GOT-SBD-B

A956GOT-LBD

LBD(-M3)Monochrome

A956GOT-TBD-M3

A956GOT-SBD-M3

A956GOT-SBD-M3-B

A956GOT-LBD-M3

A956WGOT-TBD 18 (7) Built-in communication

Show 18 more labels / short text on this page
Rough Specifications · Type · Screen size · Display color · Power · [cm (inch)] · [color] · Supply type · Built-in RS-232C · communication interface · color · liquid crystal · 15 (6) · liquid crystal · Built-in communication · liquid crystal · module interface · board/module interface
Page 19 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 1.1 Features
Page 19 · click to enlarge
Page 19

1.1 Features

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 1.1 Features diagram (page 19)
Fig. 6 · 1.1 Features

(1) Medium-size display device occupying minimum installation area The A95 GOT/A956WGOT was made smaller in outline dimensions to greatly reduce the panel cut dimensions. You can install the GOT according to your application.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 1.1 Features diagram (page 19)
Fig. 7 · 1.1 Features

59 mm (2.32 in) for A95 GOT-TBD,A95 GOT-SBD(-M3)-B,A95 GOT-QSBD(-M3)-B.

(2) Fast data transfer of OS and screen data by memory card The PC card for OS and screen data can be created easily on a personal computer. By loading the created card into the memory card interface unit, you can exchange the OS and screen data rapidly. (RS-232C data transfer can also be made as conventionally.) Also, a compact flash PC card can be used with the A956WGOT.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 1.1 Features diagram (page 19)
Fig. 8 · 1.1 Features

* ROM_BIOS cannot be installed with the compact flash PC card.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 1.1 Features diagram (page 19)
Fig. 9 · 1.1 Features

1.1 Features 1 - 3

Page 20 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 1.1 Features
Page 20 · click to enlarge
Page 20

(3) Compatible with a wide variety of connection forms The GOT models each contain their communication interfaces so that you can choose the connection form which meets your system. The A951GOT-Q, A951GOT comes with a bus communication interface to make a bus connection for fast communication, the A953GOT has an RS-232C interface and A950GOT includes an RS- 422 communication interface to make a CPU direct connection or computer link connection. The A956GOT used with a communication module can make a bus connection, MELSECNET connection or CC-Link connection. The A956WGOT used with a communication module or communication board can make a bus connection, Direct connection to CPU, computer link connection, MELSECNET connection, CC- Link connection or Ethernet connection.

(4) Heavy-duty body usable in rigorous environment and operation The standard display section of the GOT complies with the IP67 and the NEMA4 Waterproof, Dustproof Standard and is usable in a wide range of environment.

(5) Maintenance function further enhanced in affinity with PLC Upgraded alarm history function The GOT can support the failure occurrence counting function, cumulative failure time totalizing function and history printing function, and start ladder monitoring with the corresponding device searched with a single keystroke at the failure detail display time.

(6) Improvement of safety by upgraded security function

  • Supporting the operation protective function using up to 16 levels of passwords, the GOT can hide the display or disable input operation according to the password level. You can achieve hidden screens and hidden operations and easily change the display data per GOT used.
  • You can specify the time delay function (ON delay/OFF delay) of the touch switches, doublepushing switches and interlock conditions to reduce malfunctions due to wrong key pushing.

(7) Wide, easy-to-see screen (A956WGOT only) The A956WGOT can lay out more objects on the screen than it is possible with the A95 GOT. By

utilizing the monitor screen data of the A95 GOT, the A956WGOT enables numeric value entry without hiding the monitor screen with a window for numeric value entry. This is achieved by arranging the ten keys for numeric value input next to the monitor screen data.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 1.1 Features diagram (page 20)
Fig. 10 · 1.1 Features

Numeric values can be entered without hiding the monitor screen with a window for numeric value entry.

1. 4 1.1 Features
Page 21 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A95 GOT
Page 21 · click to enlarge
Page 21

2 SYSTEM CONFIGURATION

This chapter explains the system configuration of the GOT. 2.1 Overall Configuration

(1) Overall configuration of the A95*GOT The overall configuration of the A95*GOT is shown below.

Communication cable/ module connected

A9GT-50PSC

A9GT-50STAND

A9GT-50LT

e.g. A30R4-25P

Bar Code Reader 1

Bus cable for QCPU(Q mode) 1

GOT

e.g. A9GT-QC150BS

e.g. A8GT-C12NB

A95 GOT

A85GT-C05H

A8GT-50KBF

A9GT-50PRF

e.g. A9GT-Q71LP23

Memory card interface module 2 2 Printer cable 1 Printer 1

PC card (Memory card)

(e.g. key board)

A1SD59J-MIF e.g. AC30PI0-20P

e.g. A8GT-TK

*1 For details of the system configuration, refer to the [GOT-A900 Series User's Manual (Con- nection System Manual)].

*2 For details on the system configuration, refer to the User's Manual of each module.

*3 The A95*GOT-SBD(-M3)-B, A95*GOT-QSBD(-M3)-B and A95*GOT-TBD(-M3) do not require their backlights to be replaced since they are installed with long-life backlights.

2.1 Overall Configuration 2 - 1

Show 28 more labels / short text on this page
Protective sheet · Debug stand · Backlight · For A950GOT · RS-422 cable 1 · For A951GOT-Q · Commercially available · For A951GOT · Personal computer · Bus cable 1 · for drawing · For A953GOT · RS-232C cable 1 · Commercially available · Fabricated by · the user · For A956GOT · Memory card cable · External I/O module · Printer interface · Communication · module · module · Numeric key panel · Commercially · Commercially · available · available
Page 22 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 2 SYSTEM CONFIGURATION
Page 22 · click to enlarge
Page 22

(2) Overall configuration of the A956WGOT The overall configuration of the A956WGOT is shown below.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 2 SYSTEM CONFIGURATION diagram (page 22)
Fig. 11

Memory board Protective sheet Debug Stand Compact flash PC card

Memory card interface module 2 2 Printer cable 1 Printer 1

*1 For details of the system configuration, refer to the [GOT-A900 Series User's Manual (Con- nection System Manual)].

*2 For details on the system configuration, refer to the User's Manual of each module.

2. 2 2.1 Overall Configuration
Page 23 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A950GOT-SBD-M3-B
Page 23 · click to enlarge
Page 23

2.2 System Configuration of the GOT

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 2.2 System Configuration of the GOT diagram (page 23)
Fig. 12 · 2.2 System Configuration of the GOT

Each GOT incorporates a different type of communication interface and, therefore, the connection mode dif- fers from GOT to GOT used. The connections modes allowed for each GOT are shown below.

1 The A956GOT can be connected as shown above by the installation of the communication unit.

2 The A956WGOT can be connected as shown above by the installation of the communication unit and the commu-

3 For details of each connection mode, refer to the GOT-A900 Series User's Manual (Connection System Manual).

2.3 Component List

(1) List of Components Available for the A95*GOT

A950GOT-TBD High intensity TFT color liquid crystal, 256 colors, 1M byte built-in memory

A950GOT-SBD STN color liquid crystal, 8 colors, 1M byte built-in memory

A950GOT-SBD-B High intensity STN color liquid crystal, 8 colors, 1M built-in memory

A950GOT-LBD Monochrome liquid crystal, Monochrome, 1M byte built-in memory

A950GOT

High intensity TFT color liquid crystal, 256 colors, 3M byte built-in memory, compatible with

A950GOT-TBD-M3

A950GOT-SBD-M3 STN color liquid crystal, 8 colors, 3M byte built-in memory, compatible with optional OS

High intensity STN color liquid crystal, 8 colors, 3M built-in memory, compatible with optional

A950GOT-SBD-M3-B

OS

A950GOT-LBD-M3 Monochrome liquid crystal, Monochrome, 3M byte built-in memory, compatible with optional OS

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — A950GOT-SBD-M3-B diagram (page 23)
Fig. 13

2.2 System Configuration of the GOT 2 - 3

Show 4 more labels / short text on this page
Component Type Description · (Built-in RS-422 com- · optional OS · munication interface)
Page 24 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A7GT-BUS2S
Page 24 · click to enlarge
Page 24

A951GOT-QTBD High intensity TFT color liquid crystal, 256 colors,1M byte built-in memory

A951GOT-QSBD STN color liquid crystal, 8 colors,1M byte built-in memory

A951GOT-QSBD-B High intensity STN color liquid crystal, 8 colors, 1M built-in memory

A951GOT-Q

A951GOT-QLBD Monochrome liquid crystal, Monochrome,1M byte built-in memory

High intensity TFT color liquid crystal, 256 colors, 3M byte built-in memory, compatible with

A951GOT-QTBD-M3

QCPU

A951GOT-QSBD-M3 STN color liquid crystal, 8 colors, 3M byte built-in memory, compatible with optional OS

High intensity STN color liquid crystal, 8 colors, 3M built-in memory, compatible with optional

A951GOT-QSBD-M3-B

OS

A951GOT-QLBD-M3 Monochrome liquid crystal, Monochrome, 3M byte built-in memory, compatible with optional OS

A951GOT-TBD High intensity TFT color liquid crystal, 256 colors,1M byte built-in memory

A951GOT-SBD STN color liquid crystal, 8 colors,1M byte built-in memory

A951GOT-SBD-B High intensity STN color liquid crystal, 8 colors, 1M built-in memory

A951GOT

A951GOT-LBD Monochrome liquid crystal, Monochrome,1M byte built-in memory

High intensity TFT color liquid crystal, 256 colors, 3M byte built-in memory, compatible with

cation interface for A/

A951GOT-TBD-M3

CPU)

A951GOT-SBD-M3 STN color liquid crystal, 8 colors, 3M byte built-in memory, compatible with optional OS

High intensity STN color liquid crystal, 8 colors, 3M built-in memory, compatible with optional

A951GOT-SBD-M3-B

OS

A951GOT-LBD-M3 Monochrome liquid crystal, Monochrome, 3M byte built-in memory, compatible with optional OS

A953GOT-TBD High intensity TFT color liquid crystal, 256 colors,1M byte built-in memory

A953GOT-SBD STN color liquid crystal, 8 colors,1M byte built-in memory

A953GOT-SBD-B STN color liquid crystal, 8 colors, 1M built-in memory

A953GOT-LBD Monochrome liquid crystal, Monochrome,1M byte built-in memory

A953GOT

High intensity TFT color liquid crystal, 256 colors,3M byte built-in memory, compatible with

A953GOT-TBD-M3

A953GOT-SBD-M3 STN color liquid crystal, 8 colors,3M byte built-in memory, compatible with optional OS

High intensity STN color liquid crystal, 8 colors, 3M built-in memory, compatible with optional

A953GOT-SBD-M3-B

OS

A953GOT-LBD-M3 Monochrome liquid crystal, Monochrome,3M byte built-in memory, compatible with optional OS

A956GOT-TBD TFT color liquid crystal, 256 colors,1M byte built-in memory

A956GOT-SBD STN color liquid crystal, 8 colors,1M byte built-in memory

A956GOT-SBD-B High intensity STN color liquid crystal, 8 colors, 1M built-in memory

A956GOT-LBD Monochrome liquid crystal, Monochrome,1M byte built-in memory

A956GOT

High intensity TFT color liquid crystal, 256 colors,3M byte built-in memory, compatible with

A956GOT-TBD-M3

A956GOT-SBD-M3 STN color liquid crystal, 8 colors,3M byte built-in memory, compatible with optional OS

High intensity STN color liquid crystal, 8 colors, 3M built-in memory, compatible with optional

A956GOT-SBD-M3-B

OS

A956GOT-LBD-M3 Monochrome liquid crystal, Monochrome,3M byte built-in memory, compatible with optional OS

A7GT-BUSS For A956GOT, for bus connection, small connector type (For A/QnA/Motion controller CPU)

For A956GOT, for multidrop bus connection, small connector type (For A/QnA/Motion controller

A7GT-BUS2S

CPU)

Protective sheet A9GT-50PSC Transparent protective sheet for A95 GOT

Backlight A9GT-50LT Backlight for A95 GOT-SBD (-M3), A95 GOT-LBD (-M3)

2. 4 2.3 Component List
Show 18 more labels / short text on this page
Component Type Description · (Built-in bus communi- · cation interface for · optional OS · (Q mode)) · (Built-in bus communi- · optional OS · QnA/Motion controller · (Built-in RS-232C com- · optional OS · munication Interface) · (Built-in communication · optional OS · module Interface) · Bus Connection mod- · ule · Multidrop bus connec- · tion module
Page 25 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 2.2 System Configuration of the GOT
Page 25 · click to enlarge
Page 25

Debug stand A9GT-50STAND Debug stand for A95 GOT

Attachment A85GT-95ATT For replacement from A85 GOT to A95 GOT

2.3 Component List 2 - 5

Component Type Description

Page 26 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A9GT-QFNB8M
Page 26 · click to enlarge
Page 26

(2) List of Components Available for the A956WGOT

256color, 1M byte Built-in memory (Possible to expand to a maximum of 9M bytes by using a

A956WGOT A956WGOT-TBD

A9GT-50WQBUSS For bus connection, small connector type (For Q (Q mode) CPU)

A9GT-50WBUSS For bus connection, small connector type (For A/QnA/Motion controller CPU)

For Direct connection to CPU/Computer link connection/Microcomputer connection and RS-

A9GT-50WRS2

For Direct connection to CPU/Computer link connection/Microcomputer connection and RS-

A9GT-50WRS4

Protective sheet A9GT-50WPSC Transparent protective sheet for A956WGOT

Debug stand A9GT-50WSTAND Debug stand for A956WGOT

Compact flash card --- Commercially available Compact Flash PC card

A9GT-FNB Exclusively used for optional OS storage

A9GT-FNB1M For optional function OS storage + built-in memory extension, 1M byte

A9GT-FNB2M For optional function OS storage + built-in memory extension, 2M byte

A9GT-FNB4M For optional function OS storage + built-in memory extension, 4M byte

A9GT-FNB8M For optional function OS storage + built-in memory extension, 8M byte

Exclusively used for optional OS storage

A9GT-QFNB

(MELSEC-Q Ladder monitor compatible)

For optional function OS storage + built-in memory extension, 4M byte

A9GT-QFNB4M

(MELSEC-Q Ladder monitor compatible)

For optional function OS storage + built-in memory extension, 8M byte

A9GT-QFNB8M

(MELSEC-Q Ladder monitor compatible)

2. 6 2.3 Component List
Show 8 more labels / short text on this page
Component Type Description · memory board), 24VDC · Bus connection board · Serial communication · 232C connection · board · 422 connection · Memory board
Page 27 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A7GT-CNB
Page 27 · click to enlarge
Page 27

(3) List of Components Available for the A95*GOT/A956WGOT

For A956GOT/A956WGOT, for bus connection, small connector type (For A/QnA/Motion con-

Bus Connection module A9GT-BUSSU

For A956GOT/A956WGOT, for multidrop bus connection, small connector type (For QCPU (Q

A9GT-QBUS2SU

For A956GOT/A956WGOT, for multidrop bus connection, small connector type (For A/QnA/

A9GT-BUS2SU

A7GT-J71AP23 For A956GOT/A956WGOT, for MELSECNET(II) optical link connection, for use as local station

For A956GOT/A956WGOT, for MELSECNET(II) coaxial link connection, for use as local sta-

A7GT-J71AR23

A7GT-J71AT23B For A956GOT/A956WGOT, for MELSECNET/B connection, for use as local station

For A956GOT/A956WGOT, for MELSECNET/10 optical loop network connection, for use as

A9GT-QJ71LP23

ordinary station *5

For A956GOT/A956WGOT, for MELSECNET/10 coaxial bus network connection, for use as

A9GT-QJ71BR13

ordinary station *5

For A956GOT/A956WGOT, for MELSECNET/10 optical loop network connection, for use as

A7GT-J71LP23

ordinary station *5

For A956GOT/A956WGOT, for MELSECNET/10 coaxial bus network connection, for use as

A7GT-J71BR13

ordinary station *5

A8GT-J61BT13 For A956GOT/A956WGOT, for CC-Link connection, for use as intelligent device station

A8GT-J61BT15 For A956GOT/A956WGOT, for CC-Link connection, for use as remote device station

A9GT-J71E71-T For A956GOT/A956WGOT, for Ethernet connection

External I/O module A8GT-50KBF For external I/O equipment connection

Numeric keypad panel A8GT-TK Data entry Numeric Keypad Panel

A1SD59J-MIF For PC card loading

PC card --- SRAM type PC card *6 Refer to the relevant document

Printer interface module A9GT-50PRF For printer connection

Printer compliant with ESC/P24-J84(ESC/P

command compatible) *1

Hewlett Packard printers (PLC command com-

*6 Refer to the relevant document

Bar code reader --- Commercially available bar-code reader

A9GT-QCNB Used for connection of the QCPU (Q mode) long-distance bus.

For conversion from large type connector to small type connector

A7GT-CNB

(Used for connecting the CPU long-distance bus of the A/QnA Motion controller.)

2.3 Component List 2 - 7

Show 21 more labels / short text on this page
Component Type Description · troller CPU) · Multidrop bus connec- · mode)) · tion module · Motion controller CPU) · Data link module · tion · Network module · CC-Link communica- · tion module · Ethernet communica- · tion module · Memory card interface · module · Printer --- · patible) · Bus extension connec- · tor box · Bus connector conver- · sion box
Page 28 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A0J2HCPU
Page 28 · click to enlarge
Page 28

QC06B Cable length 0.6m

QC12B Cable length 1.2m

For connection between GOT and QCPU (Q

QC30B Cable length 3.0m

QC50B Cable length 5.0m

For connection between GOT and GOT

QC100B Cable length 10.0m

for QCPU (Q mode)

A9GT-QC150BS Cable length 15.0m

A9GT-QC200BS Cable length 20.0m

For connection between GOT and QCPU (Q

A9GT-QC250BS Cable length 25.0m

A9GT-QC300BS Cable length 30.0m

For connection between GOT and GOT

A9GT-QC350BS Cable length 35.0m

AC06B Cable length 0.6m

AC12B Cable length 1.2m

AC30B Cable length 3.0m

For connection between QnACPU Type/

AC50B Cable length 5.0m

AnCPU Type/motion controller CPU and

A7GT-CNB

AC12B-R Right angle, cable length 1.2m

AC30B-R Right angle, cable length 3.0m

AC50B-R Right angle, cable length 5.0m

A1SC07B Cable length 0.7m For connection between GOT and

A1SC12B Cable length 1.2m

QnASCPU Type/AnSCPU Type/motion con-

A1SC30B Cable length 3.0m

For connection between GOT and GOT

A1SC50B Cable length 5.0m

A8GT-C12NB Cable length 1.2m For connection between QnASCPU Type/

A8GT-C30NB Cable length 3.0m

AnSCPU Type/motion controller CPU and

A7GT-CNB

A8GT-C50NB Cable length 5.0m

A1SC-C05NB Cable length 0.5m

A1SC-C07NB Cable length 0.7m

For connection between GOT and QnACPU

Type/AnCPU Type/motion controller CPU

A1SC-C30NB Cable length 3.0m

A1SC-C50NB Cable length 5.0m

A8GT-C100EXSS Cable length 10.0m For connection between GOT and

A8GT-C200EXSS Cable length 20.0m

QnASCPU Type/AnSCPU Type/motion con-

A8GT-C300EXSS Cable length 30.0m

For connection between GOT and

A7GT-CNB

A8GT-C100EXSS-1 Cable length 10.0m For connection between GOT and

QnASCPU Type/AnSCPU Type/motion con-

A8GT-C200EXSS-1 Cable length 20.0m

For connection between GOT and

A8GT-C300EXSS-1 Cable length 30.0m

A7GT-CNB * 7

A8GT-C100BS Cable length 10.0m

For connection between GOT and GOT A8GT-C200BS Cable length 20.0m

A8GT-C300BS Cable length 30.0m

A370C12B-S1 Cable length 1.2m For connection between GOT and motion

controller CPU A370C25B-S1 Cable length 2.5m

A370C12B Cable length 1.2m For connection between motion controller

CPU and A7GT-CNB A370C25B Cable length 2.5m

For connection between GOT and

A9GT-J2C10B Cable length 1.0m

A0J2HCPU

2. 8 2.3 Component List
Show 8 more labels / short text on this page
Component Type Description · mode) · Bus connection cable · mode) (A9GT-QCNB required) · troller CPU · Bus connection cable · troller CPU · troller CPU
Page 29 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 2.4 Software Packages to be Used
Page 29 · click to enlarge
Page 29

AC30R4-25P Cable length 3m (D-sub 25-pin at both ends) For connection between GOT and A/

AC100R4-25P Cable length 10m (D-sub 25-pin at both ends)

For connection between GOT and FXCPU

AC300R4-25P Cable length 30m (D-sub 25-pin at both ends)

--- For connection between GOT and computer link module *2

QC30R2 Cable length 3m For connection between GOT and QCPU

For connection between GOT and personal

AC30R2-9P Cable length 3m (D-sub 9-pin, D-sub 25-pin)

computer for data transfer

AC30R2-9SS Cable length 3m (D-sub 9-pin at both ends)

For connection between GOT and personal

RS-232C cable *3

AC30R2 Cable length 3m (D-sub 25-pin at both ends)

computer for data transfer

(9-pin conversion connector required)

AC30N2A Cable length 3m (D-sub 25-pin at both ends)

--- For connection between GOT and computer link module *2

--- For connecting the GOT with the power supply unit of the bar code reader *4

Printer cable *4 AC30PIO-20P Cable length 3m For connection between GOT and printer

Screen creation software for GOT900 series GT Designer 2 ---

*1 The printer of ESC/P raster specifications such as the PM series cannot be connected and used with the GOT.

*2 The RS-422/RS-232C cable for use between GOT and computer link module should be fabricated on the user side

by referring to the [GOT-A900 Series User's Manual (Connection System Manual)].

*3 The RS-232C cable may be fabricated by the user.

The RS-232C cable can also be fabricated by the user.

Refer to the following manual for details of the cable specifications.

When GT Designer is usedGT Works Version /GT Designer Version Reference Manual
When GT Designer2 is usedGT Designer2 Version Operating Manual

*4 The printer cable may be fabricated by the user.

Refer to [A9GT-50PRF type Printer interface module User’s Manual] for full information on the specifications

needed to fabricate the cable.

*5 For the A9GT-QJ71LP23 and A9GT-QJ71BR13, the device range (QCPU, QnACPU, ACPU) that can be monitored

changes depending on the communication driver.

When the A7GT-J71LP23 or A7GT-J71BR13 is mounted, only the device range of the AnA can be monitored.

*6 Relevant document Some devices have been concluded to be applicable for GOT900 series by Mitsubishi.

For details of the devices, refer to the relevant document "List of valid devices applicable for GOT900 series "

(Technical bulletin T10-0028).

Please contact your local Mitsubishi representative for the document, if necessary.

The GOT may not operate correctly if a device other than described in the document is used.

*7 The A8GT-C100EXSS-1, A8GT-C200EXSS-1, and A8GT-C300EXSS-1 are composed of the A8GT-EXCNB (0.5m)

A8GT-C100BS (10m), A8GT-C200BS (20m), and A8GT-C300BS (30m) respectively.

When calculating the cable length, the A8GT-EXCNB‘s cable length can be ignored.

2.4 Software Packages to be Used

When a GOT is used, a software package of the applicable version or later is required. The versions of the software packages required for each GOT are shown below.

2.4 Software Packages to be Used 2 - 9

Show 5 more labels / short text on this page
Component Type Description · QnACPU · RS-422 cable · GT Designer --- · and the
Page 30 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A9GT-80PSC, A9GT-80PSCL, A9GT-70PSC, A9GT-70PSCL, A9GT-60PSC, A9GT-60PSCL,
Page 30 · click to enlarge
Page 30

SW0D5C-GTWORKS-E Version A or later, SW4D5C-GOTR-

A950GOT-TBD(-M3)

PACKE Version A or later

A950GOT-SBD(-M3) SW0D5C-GTWORKS-E Version A or later, SW1D5C-GOTRE-

PACK Version H or later A950GOT-LBD(-M3)

SW0D5C-GTWORKS-E Version A or later, SW4D5C-GOTR-

A951GOT-QTBD(-M3)

PACKE Version A or later

A951GOT-QSBD(-M3) SW0D5C-GTWORKS-E Version A or later, SW3D5C-GOTRE-

PACK Version C or later A951GOT-QLBD(-M3)

SW0D5C-GTWORKS-E Version A or later, SW4D5C-GOTR-

A951GOT-TBD(-M3)

PACKE Version A or later

A951GOT-SBD(-M3) SW0D5C-GTWORKS-E Version A or later, SW1D5C-GOTRE-

SW1D5C-GTWK2-E A or later

PACK Version H or later A951GOT-LBD(-M3)

SW1D5C-GTD2-E A or later

SW0D5C-GTWORKS-E Version A or later, SW4D5C-GOTR-

A953GOT-TBD(-M3)

PACKE Version A or later

A953GOT-SBD(-M3) SW0D5C-GTWORKS-E Version A or later, SW1D5C-GOTRE-

PACK Version H or later A953GOT-LBD(-M3)

SW0D5C-GTWORKS-E Version A or later, SW4D5C-GOTR-

A956GOT-TBD(-M3)

PACKE Version A or later

A956GOT-SBD(-M3) SW0D5C-GTWORKS-E Version A or later, SW1D5C-GOTRE-

PACK Version H or later A956GOT-LBD(-M3)

SW5D5C-GTWORKS-E Version K or later, SW5D5C-GOTR-

A956WGOT-TBD

PACKE Version K or later

A950GOT-SBD(-M3)-B

A951GOT-QSBD(-M3)-B

SW1D5C-GTWK2-E Version Q or later

SW5D5C-GTWORKS-E Version Q or later

A951GOT-SBD(-M3)-B

SW1D5C-GTD2-E Version Q or later

SW5D5C-GOTRE-PACK Version Q or later

A953GOT-SBD(-M3)-B

A956GOT-SBD(-M3)-B

2.5 Unusable Conventional Products

The following conventional products cannot be used with this GOT.

Bus connection board A9GT-BUSS, A9GT-BUS2S

Bus connection module A7GT-BUS, A9GT-BUS2

Serial communication board A9GT-RS2, A9GT-RS4

Serial communication module A8GT-RS2, A8GT-RS4

Backlight A9GT-70LTT, A9GT-70LTS, A9GT-70LTTB, A9GT-80LTT, A8GT-70LTT, A8GT-70LTS, A8GT-50LT

Ladder monitoring cassette A8GT-MCAM

Extension memory cassette A8GT-MCA1MFDW, A8GT-MCA2MFDW, A8GT-MCA3MFDW

Extension memory board A9GT-FNB, A9GT-FNB1M, A9GT-FNB2M, A9GT-FNB4M

A9GT-80PSC, A9GT-80PSCL, A9GT-70PSC, A9GT-70PSCL, A9GT-60PSC, A9GT-60PSCL,

A8GT-70PSCE, A8GT-70PSNE, A8GT-70PSCS, A8GT-70PSNS, A8GT-50PSC, A8GT-50PSN

Printer interface module A8GT-70PRF, A8GT-50PRF

External I/O module A9GT-70KBF, A8GT-70KBF

Debug stand A9GT-80STAND, A9GT-70STAND, A8GT-70STAND, A8GT-50STAND

Option module mounting fixture A8GT-50STE

2. 10 2.5 Unusable Conventional Products
Show 8 more labels / short text on this page
Compatible software package · Type · GT Works 2 · GT Works · GT Designer 2 · GT Designer · Component Type · Protective sheet
Page 31 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 2.6 Notes on Q4ARCPU Duplex System
Page 31 · click to enlarge
Page 31

2.6 Notes on Q4ARCPU Duplex System

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 2.6 Notes on Q4ARCPU Duplex System diagram (page 31)
Fig. 14 · 2.6 Notes on Q4ARCPU Duplex System

This section describes the notes on the connecting of the Q4ARCPU with the GOT, as follows:

(1) Notes on the additional base for duplex system at the final stage: To connect the duplex system with the GOT via the bus, connect the GOT with the additional base for duplex system (A68RB) that is provided at the final stage of the duplex system. To use the additional base for duplex system, please apply that of the Version B or after.

  • In the following configurations the GOT will not operate normally as specified.

(a) The configuration in which the GOT is connected with the fundamental base for the duplex

system (A32RB, A33RB) is connected via the bus.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 2.6 Notes on Q4ARCPU Duplex System diagram (page 31)
Fig. 15 · 2.6 Notes on Q4ARCPU Duplex System

(b) The configuration in which the GOT is connected with the additional base (A68RB) for duplex

system of Version A is connected via the bus.

  • To check and confirm the version of the additional base for duplex system, please refer to the DATE column on the rating plate that is adhered to the part as shown in the illustration below.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 2.6 Notes on Q4ARCPU Duplex System diagram (page 31)
Fig. 16 · 2.6 Notes on Q4ARCPU Duplex System

2.6 Notes on Q4ARCPU Duplex System 2 - 11

Page 32 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — OFF
Page 32 · click to enlarge
Page 32

(2) Notes on 5V DC supply for the additional base (A68RB) for duplex system at the final stage: 220mA of current to be consumed will be supplied from the additional base for duplex system at the final stage to the GOT bus interface, if the GOT power supply is off and the power supply for the power supply module mounted on the additional base for duplex system at the final stage is on. Therefore, please make sure that the 5V DC consumption (8A) of the power supply module will not be exceeded by the sum of the value of the current consumption of the input/output module and special function module that are mounted on the additional base for duplex system at the final stage and the value of the current consumption (220mA) of the GOT bus interface.

Power on the GOT-A900 series and Q4ARCPU duplex system in the following order.

(1) Power on the GOT-A900 series. (2) 1 to 2 seconds after power-on of the GOT-A900 series, power on the Q4ARCPU

duplex system.

A61RP

Power supply of Q4ARCPU duplex system

Power supply of Q4ARCPU duplex system

ON

A61RP

OFF

ON

GOT Power supply of GOT-A900 series

Power supply of GOT-A900 series

OFF

It is recommended to switch power on with an external circuit configured.

If power is not switched on in the order as specified in the restriction, the Q4ARCPU duplex system will not start up in system A but will start up in system B before it starts control.

2. 12 2.6 Notes on Q4ARCPU Duplex System
Show 4 more labels / short text on this page
Main base · 1 to 2s · Extension base · Bus connection cable
Page 33 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — IEC
Page 33 · click to enlarge
Page 33

3.1 General Specifications

The general specifications of the GOT are indicated below.

A95*GOT0 to 40
A956WGOT0 to 55

Other than display section 0 to 55

temperature -20 to 60

10 to 90 % RH, non-condensing

10 to 90 % RH, non-condensing

Frequency Acceleration Amplitude Sweep Count

10 to 57 Hz --- 0.075 mm

10 times in each

to JIS B3502 and

57 to 150 Hz 9.8 m/s2 ---

of X, Y and Z

IEC

10 to 57 Hz --- 0.035 mm

57 to 150 Hz 4.9 m/s2 ---

Shock resistance Conforms to JIS B3502, IEC 61131-2 (147 m/s2, 3 times in each of X, Y and Z directions)

Operating altitude 2000 m(6562 ft) max.

Installation site Inside control box

Overvoltage category *1 II or less

Contamination level *2 2 or less

*1 Indicates the element in the distribution system between the public electricity grid and the mechanical equipment

inside the premises that the relevant device is assumed to be connected to.

Category II applies to devices such as those that draw their power supply from fixed installations.

The surge voltage withstand capability of devices with ratings up to 300V is 2,500V.

*2 This index gives a measure of the incidence of conductive materials in the environment in which the device is used.

A contamination level of 2 indicates an environment in which there is only contamination by non-conducting

materials, but due to occasional condensation, conductivity may occur.

*3 Please do not use or store GOT in an environment with atmospheric pressure greater than the atmospheric

pressure at sea level (0m).

There is a possibility errors may occur if this point is not observed.

3.1 General Specifications 3 - 1

Show 24 more labels / short text on this page
Item Specifications · Display section · Operating ambient · temperature · Storage ambient · Operating ambient · humidity · Storage ambient · humidity · In case of · Conforms · intermittent · Vibration · vibration · resistance · In case of · directions (for 80 · 61131-2 · continuous · minutes) · vibration · Operating · No corrosive gas · atmosphere *3
Page 34 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — SW4D5C-GOTRE-PACK
Page 34 · click to enlarge
Page 34

3.2 Performance Specifications

(1) The performance specifications of the A951GOT-Q are shown below.

A951GOT-QTBD

A951GOT-QSBD

A951GOT-QSBD

A951GOT-QLBD

(-M3)

(-M3)-B

(-M3)

(-M3)

Display section For details of display specifications, refer to Section 3.2 (4)

keys 300 points (15 lines 20 columns)

Key size Minimum 16 16 dots (per key)

Application For monitor screen data storage, for OS storage

Capacity 1M byte built-in (user area) (-M3 has 3M bytes and is compatible with optional OS)

Reference value for data

When installing OS: 640 to 760 seconds (For basic functions, BUS driver and system monitor (approx.

1.3Mbytes))

When downloading screen data330 to 570 seconds (For approx. 30 screens (approx. 600kbytes))

Interface Built into main unit Bus communication interface for QCPU (Q mode) 1 cannel

Option module interface for option module loading, 1 channel

RS-232C interface For connection of personal computer, for bar-code reader connection, 1 channel

Buzzer output Single tone (tone length adjustable)

Touch key 1 million times or more (operating force 0.98N max.)

Built-in memory Number of write times: 100,000 times

Front sectionEquivalent to IP67/NEMA4
Panel insideIP2X
TBD(-M3)/SBD(-M3)-B164.5 (6.48) (W) 136 (5.35) (H) 65 (2.56) (D) mm (inch)
SBD(-M3)/LBD(-M3)164.5 (6.48) (W) 136 (5.35) (H) 57 (2.24) (D) mm (inch)

Panel cutting dimensions 156 (6.14) (W) 123.5 (4.86) (H) mm (inch)

Weight 0.71 (1.56) kg(lb) 0.75 (1.65) kg (lb) 0.67 (1.47) kg (lb)

SW1D5C-GTWK2-E

Version 1.17T or later/

SW1D5C-GTD2-E

Supported from the first

Version 1.17T or later

Supported from the first version (Version 1.00A)

version (Version 1.00A)

SW2D5C-GTWK2-E

Version 2.04E or later/

SW2D5C-GTD2-E

Version 2.04E or later

SW0D5C-GTWORKS-E

Supported from the SW0D5C-GTWORKS-E Version

Version A or later/

A or later/SW3D5C-GOTRE-PACK Version C or

SW4D5C-GOTRE-PACK

Version A or later

*1 The built-in memory is ROM which allows old data to be overwritten by new data. (Data backup power supply is not

needed.)

*2 When parts must be changed, consult your sales representative.

3. 2 3.2 Performance Specifications
Show 27 more labels / short text on this page
Specifications · Item · Number of touch · Touch · panel · Repeat function No · Type Flash ROM · Memory · *1 · transmission time · (For RS-232C communication) · Life *2 · Environmental protective · structure *3 · Outline dimensions · Supported from the · GT Works2 · GT Designer2 · Supported from the · Compatible · software · package · Supported from the · GT Works · No support · GT Designer · later
Page 35 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A951GOT-QSBD(-M3)
Page 35 · click to enlarge
Page 35

*3 The environmental protective structure (IP rating) differs depending on the hardware version of GOT.

A951GOT-QSBD(-M3)

A951GOT-QTBD(-M3)

A951GOT-QSBD(-M3)-B

A951GOT-QLBD(-M3)

Front sectionEquivalent

Hardware version A or later ---

Panel insideIP2X
Front sectionEquivalent

Hardware version A or later

(Jul., 2001) or later

(Jul., 2001) or later

Panel insideIP2X

3.2 Performance Specifications 3 - 3

Show 9 more labels / short text on this page
Specification · Item · to IP65 · Environmental · protective · structure · Hardware version B · Hardware version H · to IP67/NEMA4
Page 36 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A950GOT-TBD(-M3)
Page 36 · click to enlarge
Page 36

(2) The performance specifications of the A950/951/953/956GOT are shown below

A950GOT-TBD(-M3)

A951GOT-TBD(-M3)

A953GOT-TBD(-M3)

A956GOT-TBD(-M3)

A950GOT-SBD(-M3)-B

A951GOT-SBD(-M3)-B

A953GOT-SBD(-M3)-B

A956GOT-SBD(-M3)-B

A950GOT-SBD(-M3)

A951GOT-SBD(-M3)

A953GOT-SBD(-M3)

A956GOT-SBD(-M3)

A950GOT-LBD(-M3)

A951GOT-LBD(-M3)

A953GOT-LBD(-M3)

A956GOT-LBD(-M3)

Display section For details of display specifications, refer to Section 3.2 (4)

keys 300 points (15 lines 20 columns)

Key size Minimum 16 16 dots (per key)

Application For monitor screen data storage, for OS storage

Capacity 1M byte built-in (user area) (-M3 has 3M bytes and is compatible with optional OS)

Reference value for data

When installing OS640 to 760 seconds (For basic functions, BUS driver and system monitor

(approx. 1.3Mbytes))

When downloading screen data330 to 570 seconds (For approx. 30 screens (approx. 600kbytes))

Interface Built into main unit

Option module interface for option module loading, 1 channel

RS-232C interface For connection of personal computer, for bar-code reader connection, 1 channel

Buzzer output Single tone (tone length adjustable)

Touch key 1 million times or more (operating force 0.98N max.)

Built-in memory Number of write times: 100,000 times

Front sectionEquivalent to IP67/NEMA4
Panel insideIP2X
SBD(-M3)-B, TBD(-M3)164.5 (6.48) (W) 136 (5.35) (H) 65 (2.56) (D) mm (inch)
SBD(-M3)/LBD(-M3)164.5 (6.48) (W) 136 (5.35) (H) 57 (2.24) (D) mm (inch)

Panel cutting dimensions 156 (6.14) (W) 123.5 (4.86) (H) mm (inch)

Weight TBD0.71 (1.56) kg(lb) SBD/LBD: 0.67 (1.47) kg(lb) SBD(-M3)-B: 0.75 (1.65) kg(lb)
TBD(-M3)/SBD(-M3)/LBD (M-3)Supported from the first version (Version 1.00A)
SBD (-M3)-BSupported from the SW1D5C-GTWK2-E Version 1.17T or later/ SW1D5C-

GTD2-E Version 1.17T or later

Supported from the SW2D5C-GTWK2-E Version 2.04E or later/ SW2D5C-

GTD2-E Version 2.04E or later

TBD(-M3)Supported from the SW0D5C-GTWORKS-E Version A or later/SW4D5C-GOTRE -

PACK Version A or later

SBD (-M3)-B)No support
SBD(-M3)/LBD (M-3)Supported from the SW0D5C-GTWORKS-E Version A or later/SW1D5C-GOTRE -

PACK Version H or later

*1 The ROM which allows old data to be overwritten by new data. (Data backup power supply is not needed.)

*2 When parts must be changed, consult your sales representative.

3. 4 3.2 Performance Specifications
Show 33 more labels / short text on this page
Specifications · Item · Number of touch · Touch · panel · Repeat function No · Type Flash ROM · Memory · *1 · transmission time · (For RS-232C communication) · For RS-422 · For RS-232C · For communication · For bus communication · communication · communication · module mounting · 1 channel · 1 channel · 1 channel · 1 channel · Life *2 · Environmental protective structure · *3 · Outline dimensions · GT Works2 · GT Designer2 · Compatible · software · package · GT Works · GT Designer
Page 37 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — IP2X
Page 37 · click to enlarge
Page 37

*3 The environmental protective structure (IP rating) differs depending on the hardware version of GOT.

A950GOT-TBD

A950GOT-SBD

A950GOT-SBD

(-M3)

(-M3)

(-M3)-B

A951GOT-TBD

A950GOT-LBD

A953GOT-SBD

A956GOT-SBD

A951GOT-SBD

(-M3)

(-M3)

(-M3)

(-M3)

(-M3)-B

A953GOT-TBD

A951GOT-SBD

A953GOT-LBD

A956GOT-LBD

A953GOT-SBD

(-M3)

(-M3)

(-M3)

(-M3)

(-M3)-B

A956GOT-TBD

A951GOT-LBD

A956GOT-SBD

(-M3)

(-M3)

(-M3)-B

Front section:

IP65

Hardware version A or later ---

Panel inside:

IP2X

Front section:

IP67/NEMA4

(Jul., 2001)

(Jul., 2001)

(Jul., 2001)

(Jul., 2001)

Panel inside:

IP2X

3.2 Performance Specifications 3 - 5

Show 17 more labels / short text on this page
Specification · Item · Equivalent to · Environmental · protective · structure · Equivalent to · Hardware version B · Hardware version L · Hardware version M · Hardware version K · Hardware version A · or later · or later · or later · or later · or later
Page 38 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A956WGOT-TBD
Page 38 · click to enlarge
Page 38

(3) The performance specifications of the A956WGOT are shown below.

A956WGOT-TBD

Display section For details of display specifications, refer to Section 3.2 (4)

keys 450 points (15 lines 30 columns)

Key size Minimum 16 16 dots (per key), (8 16 only for bottom line)

Application For monitor screen data storage, for OS storage

Capacity 1M byte built-in (user area), max. 8M bytes increasable

When installing OS640 to 760 seconds (For basic functions, BUS driver and system monitor

(approx. 1.3Mbytes))

When downloading screen data330 to 570 seconds (For approx. 30 screens (approx. 600kbytes))

Communication board slot *2 For communication board loading, 1 slot

For communication module loading, 1 channel

Option module interface For option module loading, 1 channel

Compact flash card interface For Compact flash PC card loading, 1 channel

Memory board slot For memory board loading, 1 slot

RS-232C interface For connection of personal computer, for bar-code reader connection, 1 channel

Buzzer output Single tone (tone length adjustable)

Touch key 1 million times or more (operating force 0.98N max.)

Built-in memory Number of write times: 100,000 times

Front sectionEquivalent to IP67/NEMA4
Panel insideIP2X

Outline dimensions 215 (8.46) (W) 133 (5.24) (H) 70.8 (2.79) (D) mm (inch)

Panel cutting dimensions 205.5 (8.09) (W) 123.5 (4.86) (H) mm (inch)

Weight 1.05 (2.31) kg (lb)

Compatible software package *4 SW5D5C-GTWORKS-E Version K or later, SW5D5C-GOTR-PACKE Version K or later

*1 The built-in FLASH ROM memory allows old data be overwritten by new data. (Data backup power supply is not

needed.)

*2 Note that either of the communication board slot and communication module interface may only be used.

*3 When parts must be changed, consult your sales representative.

*4 GT Works2 and GT Designer2 are compatible, starting with the initial products (Version 1.00A).

3. 6 3.2 Performance Specifications
Show 16 more labels / short text on this page
Specifications · Item · Number of touch · Touch · panel · Repeat function No · Type Flash ROM · Memory · *1 · Reference value for · data transmission time · (For RS-232C communication) · Communication module · interface*2 · Life *3 · Environmental protective structure
Page 39 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 3.2 Performance Specifications
Page 39 · click to enlarge
Page 39
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 3.2 Performance Specifications diagram (page 39)
Fig. 17 · 3.2 Performance Specifications

Display color 256 colors 8 colors 2 monochrome colors *7 256 colors

Intensity 350cd/m2 350cd/m2 110cd/m2 200cd/m2 300cd/m2

Backlight Cold-cathode tube backlight (Backlight OFF/Screen saving time settings are available.)

Display *5 *6 50,000h (Operating ambient temperature: 25 )

(Time period until the intensity becomes 50%, based on the assumption the

*1 If you run the monitor with A956WGOT, the screen may flicker depending on the type of object/shape fill pattern

This is due to the specifications of the LCD panel and is not a malfunction.

Be sure to check the combination of the type of pattern and color on the machine before using.

For patterns likely to flicker and countermeasures against flickers, refer to the PDF manual stored in the used

drawing software.

*2 Depending on the display color combination, the visibility of the screen may be lower from certain viewpoints.

Before using, check the color combination with the machine installed in the usage environment.

By designating bright colors for the basic color types, you can decrease the chances of this phenomenon occurring.

*3 For A95*GOT-(Q)TBD(-M3), A95*GOT-(Q)SBD(-M3)-B and A956WGOT the backlight needs not be replaced, as

they include a backlight of increased life.

*4 When parts must be changed, consult your sales representative.

*5 The screen saving/back light OFF function of GOT is extended, thus reducing burning prevention of the display

panel and extending longevity of the back light.

*6 Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to

completely avoid this symptom, as the liquid crystal display comprises of a great number of display elements.

Please note that these dots appear due to its characteristic and are not caused by product defect.

*7 A screen created with GT Designer2 is displayed with reversing (white/black) on GOT.

The same display image as a screen created with GT Designer2 can be set for the display on GOT with [Setup] of

the utility.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 3.2 Performance Specifications diagram (page 39)
Fig. 18 · 3.2 Performance Specifications

When setting [Reverse display] to [Yes]: The display is the same as one created with GT Designer2.

When setting [Reverse display] to [No]: The reversed (white/black) display of a screen created with GT Designer2

For how to operate the utility, refer to the GOT-A900 Series Operating Manual (Extended Option Functions

3.2 Performance Specifications 3 - 7

Page 40 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A950GOT, A951GOT-Q, A951GOT, A953GOT A956GOT A956WGOT
Page 40 · click to enlarge
Page 40

3.3 Power Supply Specifications

A950GOT, A951GOT-Q, A951GOT, A953GOT A956GOT A956WGOT

Input power supply voltage 24VDC (+10%, -15%)

Input max. power 12W 16W 22W

Inrush current 40Ap, max. (26.4VDC, max. load)

Permissible instantaneous power failure time 1 ms (19.2VDC or more)

Noise immunity By noise simulator of 500Vp-p noise voltage, 1_s noise width and 25 to 60Hz noise frequency

Dielectric withstand voltage 500VAC for 1 minute across DC external terminals and earth

Insulation resistance 10M or larger by insulation resistance tester

Applicable wire size 0.75 to 2 mm2

Applicable solderless terminal RAV1.25-3, V2-S3.3,V2-N3A, FV2-N3A

(Terminal block terminal screw) 59 to 88 N cm2

Remark When an instantaneous power failure occurs for the time exceeding the permissible instantaneous power failure time in the 24VDC power supply, the GOT may be reset. In such a case, the GOT will automatically return and start communicating.

As the communication between the GOT and PLC is stopped when an instantaneous power failure occurs, some object functions may not be performed normally.

3. 8 3.3 Power Supply Specifications

Specifications · Item · Applicable tightening torque

Page 41 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — POWER
Page 41 · click to enlarge
Page 41

4 NAMES OF THE PARTS AND THEIR SETTINGS

(1) Names of the Parts and Their Settings of the A95 GOT are indicated below.

1. 5) 3)

POWER

8. 2) 11) 10) 9) 7) 9)
4. *1 6)

*1: The shape of the interface section changes depending on the GOT.

No. Name Description

1. Display section Shows the screen
2. Reset button Used to reset the hardware of the GOT (invalid for bus connection)

Used to set the extension number for GOT assignment

Extension number setting switch, (A951GOT only)

1 to 7Extension number
8, 9, 0Must not be used

Used to set the I/O slot number for GOT assignment

I/O slot setting switch (A951GOT only)

0 to 7I/O slot number
8, 9Must not be used

For RS-422 communication connection

RS-422 communication interface (A950GOT only)

(D-sub 25-pin female metric screw type)

Bus communication interface for QCPU (Q mode)

For bus connection cable connection (For QCPU (Q mode))

For bus communication cable connection

(For A/QnA/Motion controller CPU)

For RS-232C communication cable connection

(D-sub 9-pin male inch screw type)

5. Communication module interface (A956GOT only) Interface for loading the communication module

For connection of personal computer

6. RS-232C interface

For connecting the bar code reader (D-sub 9-pin male inch screw type)

7. Option module interface For connection Printer I/F module, Memory card I/F module, External I/O module
8. Terminal block For power input
9. Mounting fixture fitting portion For mounting fixture fitting
10. Ground terminal For earthling (For safety, please make sure to ground this terminal.)
11. Rating plate ---
Show 7 more labels / short text on this page
3) · (A951GOT only) · 4) · Bus communication interface · (A951GOT only) · RS-232C communication interface · (A953GOT only)
Page 42 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 4 NAMES OF THE PARTS AND THEIR SETTINGS
Page 42 · click to enlarge
Page 42

(2) Names of the Parts and Their Settings of the A956WGOT are indicated below.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 4 NAMES OF THE PARTS AND THEIR SETTINGS diagram (page 42)
Fig. 19

No. Name Description

1. Display section Shows the screen
2. Reset button Used to reset the hardware of the GOT (invalid for bus connection)

Used to set the condition of access to the compact flash PC card when it is loaded during

power-on (Factory-set to OFF)

OFF :Access from GOT to compact flash PC card inhibited

3. Compact flash PC card access switch

ON :Access from GOT to compact flash PC card enabled

(When a memory card interface unit is used, a compact flash PC card cannot be used. There-

fore, turn this switch OFF.)

Indicates whether the compact flash PC card may be loaded/unloaded or not

OFF :Compact flash PC card may be loaded/unloaded

4. Compact flash PC card LED

(When switch 3 is OFF)

ON :Compact flash PC card must not be loaded/unloaded

(When switch 3 is ON)

For connection of personal computer

5. RS-232C interface

For connecting the bar code reader

6. Communication module interface Interface for communication module loading
7. Compact flash card slot Slot for Compact flash PC card loading
8. Option module interface For connection Printer I/F module, Memory card I/F module, External I/O module
9. Slot cover Cover of the memory board slot and the communication board slot
10. Memory board slot Slot for memory board loading
11. Communication board slot Slot for communication board loading
12. Terminal block For power input
13. Mounting fixture fitting portion For mounting fixture fitting
14. Ground terminal For earthing (For safety, please make sure to ground this terminal.)

For confirming the extension number of the I/O slot number set with the bus connection board

15. Bus connection board setting switch confir-

(If you are not using the A9GT-50WBUSS, it is possible to attach the seal included with the

GOT main unit to cover the hole.)

mation hole

Page 43 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — COMPLETE
Page 43 · click to enlarge
Page 43
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 5 ROUGH PRE-OPERATION PROCEDURE diagram (page 43)
Fig. 20

This chapter gives a rough procedure to be performed before starting the operation of the GOT.

START

For GT Designer:

Refer to GT Works Version / GT Designer Version Operating Manual (Startup Manual) For GT Designer2:

Install GT Designer (2) into personal computer.

Refer to GT Works2 Version / GT Designer2 Version Operating Manual (Startup Introductory Manual)

For GT Designer:

Create monitor screen data.

Refer to GT Designer help function For GT Designer2:

Refer to GT Designer2 Version Reference Manual

Perform wiring to supply power to GOT.

Refer to Section 6.3

Install the memory board (only when necessary)

Refer to Section 6.4

To transfer data through cable To transfer data through Compact Flash PC card/PC card

Connect GOT and personal computer by RS-232C cable.

Load PC card into personal computer.

Install personal computer-installed OS program and monitor screen data into GOT.

Install personal computer-installed OS program and monitor screen data to Compact Flash PC card/PC card.

For GT Designer:

Refer to GT Works Version /GT Designer Version Reference Manual For GT Designer2:

1. Install basic OS, communication driver, extension function OS into GOT. 2) Reset GOT power on completion of installation. 3) Download screen data created on personal computer.
1. Copy basic OS, communication driver, extension function OS to PC card. 2) Copy screen data created on personal computer to PC card.

Refer to GT Designer2 Version Operating Manual

Load Compact Flash PC card/PC card into GOT, and install OS program and monitor screen data (copy them to built-in memory).

Load various modules to GOT.

Refer to Chapter 6

Make switch setting of communication unit or communication board.

Refer to GOT-A900 Series User's Manual (Connection System Manual)

Connect cables to GOT and required connectors.

Switch on GOT and connected system.

Start monitoring. (Use various monitoring functions.)

Refer to GOT-A900 Series Operating Manual (Extended Option Functions Manual)

COMPLETE

Page 44 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — Memo
Page 44 · click to enlarge
Page 44

Memo

Page 45 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — CAUTION
Page 45 · click to enlarge
Page 45

This chapter explains how to handle the GOT main unit and components.

6.1 GOT Main Unit

6.1.1 Handling instructions

This section describes the instructions for handling the GOT main unit and components.

Before installing or removing the GOT main unit to or from an enclosure, always turn the GOT power OFF before installing or removing the GOT main unit to or from an enclosure. Not doing so can cause a module failure or malfunction. Before loading or unloading the communication module, communication board, external I/O interface module or memory card interface module to or from the GOT, always turn the GOT power OFF before loading or unloading the communication module, external I/O interface module or memory card interface module to or from the GOT. Not doing so can cause a module failure or malfunction. Before starting wiring, always turn the GOT power OFF before starting wiring. Not doing so may cause an electric shock, product damage or malfunction.

DANGER

The GOT should be used in the environment given in the general specifications of this user's manual. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration. When mounting the GOT main unit to an enclosure, tighten the mounting screws in the specified torque range. Undertightening can cause a drop, short circuit or malfunction. Overtightening can cause a drop, short circuit or malfunction due to the damage of the screws or module. When loading the communication module to the GOT main unit, fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range. Undertightening can cause a drop, failure or malfunction. Overtightening can cause a drop, failure or malfunction due to the damage of the screws or module. Please make sure to ground FG terminal of the GOT power supply unit by applying Class D Grounding (Class 3 Grounding) Method or higher which is used exclusively for the GOT. Correctly wire the power supply module on the GOT after confirming the rated voltage and terminal arrangement of the product. Not doing so can cause a fire or failure. Exercise care to avoid foreign matter such as chips and wire offcuts entering the module. Not doing so can cause a fire, failure or malfunction.

CAUTION

6.1 GOT Main Unit 6.1.1 Handling instructions 6 - 1

Page 46 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — GOT
Page 46 · click to enlarge
Page 46

Tighten the terminal screws of the GOT power supply section in the specified torque range. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or module. Plug the bus connection cable by inserting it into the connector of the connected module until it "clicks". After plugging, check that it has been inserted snugly. Not doing so can cause a malfunction due to a contact fault. Plug the communication cable into the connector of the connected module and tighten the mounting and terminal screws in the specified torque range. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or module. Do not touch the conductive and electronic parts of the module directly. Doing so can cause a module malfunction or failure.

CAUTION

(1) Do not drop the module or give it strong impact. Doing so can cause a failure because the display device is made of glass.

(2) Do not remove the printed circuit board of the module from the case. Doing so can cause a failure.

(3) When mounting the main unit to a control box or the like, set the display section as shown below.

  • When the temperature inside the enclosure is 40 to 55 or less, the mounting angle should be in

the range 60 to 105 degrees.

GOT

Enclosure, etc.

  • The GOT will be deteriorated earlier if it is used at the mounting angle other than the above. Therefore, the temperature inside the enclosure should be within 40 .

(4) Tighten the screws in the following specified range.

Screw Location Tightening Torque Range

Ground terminal screw (M3 screw)

59 to 88N cm Terminal block terminal screw (M3 screw)

Module mounting screw (M4 screw)

Communication board mounting screw (M3 screw)

Communication module mounting screw (M3 screw)

36 to 48N cm

Option module mounting screw (M3 screw)

Case fixing screw (M3 screw)

Memory board mounting screw (M2.6 screw) 25 to 35N cm

RS-232C connector mounting screw (#4-40 UNC (inch screw)) 20 to 28N cm

Bus connection cable connector mounting screw for QCPU

(Q mode) 20N cm

6. 2 6.1 GOT Main Unit 6.1.1 Handling instructions

Display section · 60° 105°

Page 47 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A
Page 47 · click to enlarge
Page 47

6.1.2 Installation method

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.1.2 Installation method diagram (page 47)
Fig. 21 · 6.1.2 Installation method

(1) Mounting panel cutting dimensions When mounting the GOT on a control box door, user-made mounting base or the like, the door or mounting base must be cut as indicated below.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.1.2 Installation method diagram (page 47)
Fig. 22 · 6.1.2 Installation method

A

B

(2) Mounting position When mounting the GOT, the following clearances must be left from the other device.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — A diagram (page 47)
Fig. 23

Plate thickness within 2 to 4mm (0.08 to 0.16inch)

Part A sizeBecause the connection cable of the GOT is pulled downward, the following space is

required according to its radius of curvature.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — A diagram (page 47)
Fig. 24

Part B size: Please allow a gap 80mm (3.15inch) or more from the structure and other equipment in

the upper part of the unit to often allow good ventilation. Part C size: When installing devices that generate radiated noise (such as a contactor) or a device

that generate heat near the GOT, always leave a clearance of 100mm (3.94inch) or more to the back and 50mm (1.97inch) or more to the left and right to avoid the effects of the noise and heat.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — A diagram (page 47)
Fig. 25

Depending on the type of the cable to be connected to the GOT main body, longer clearances than those specified above may be required.

When mounting a GOT, be sure to consider the dimensions of the connector and the cable bend radius.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — A diagram (page 47)
Fig. 26

6.1 GOT Main Unit 6.1.2 Installation method 6 - 3

Panel opening

Page 48 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.1.2 Installation method
Page 48 · click to enlarge
Page 48

(a) Put the GOT main unit into the panel opening, with its front face first.

(b) Mount the GOT in the following four locations at its top and bottom.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.1.2 Installation method diagram (page 48)
Fig. 27 · 6.1.2 Installation method

(c) How to mount and fix the mounting fixture is given below.

1. Insert the mounting fixture into the fixture fitting portion of the GOT main unit. 2) Tighten and fix the mounting screw in the specified torque range.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.1.2 Installation method diagram (page 48)
Fig. 28 · 6.1.2 Installation method
6. 4 6.1 GOT Main Unit 6.1.2 Installation method

(3) Mounting method

Page 49 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — Remark General view of noise countermeasures
Page 49 · click to enlarge
Page 49

6.1.3 Wiring method

Completely turn off the externally supplied power used in the system when installing or placing wiring. Not completely turning off all power could result in electric shock, damage to the product.

DANGER

Be sure to ground the FG terminal and LG terminal of the GOT power supply section to the protective ground conductor. Not doing so could result in electric shock or erroneous operation.

CAUTION

When wiring in the GOT power section, be sure that it is done correctly by checking the product's rated voltage and the terminal layout. Connecting a power supply that is different from the rating or incorrectly wiring the product could result in fire or erroneous operation.

Tighten the terminal screws of the GOT power supply section within the specified torque range. If the terminal screws are loose, it could result in short circuits, erroneous operation or erroneous operation. Tightening the terminal screws too far may cause damages to the screws and/or the module, resulting in fallout, short circuits, or erroneous operation.

Be sure there are no foreign substances such as sawdust or wiring debris inside the GOT main unit.

Remark General view of noise countermeasures

There are two types of noise: radiated noise, which is transmitted through the air, and conducted noise, which is transmitted through a connection wire. In noise countermeasures, the both two types of noise should be taken into account. As the noise countermeasures, there are the following three methods. (1) Block noise

(a) Keep signal wires away from a possible noise source as power wires or high-

power driving circuits.

(b) Shield signal wires.

(2) Reduce generated noise

(a) Reduce the noise generated from high-power motor drive circuits.

(3) Ground noise without fail

(a) Earth the grounding wire to the ground without fail.

(b) Use a grounding wire as thick and short as possible to ensure low grounding

impedance.

(c) Separate the grounding between power and control systems.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — Remark General view of noise countermeasures diagram (page 49)
Fig. 29 · Remark General view of noise countermeasures

6.1 GOT Main Unit 6.1.3 Wiring method 6 - 5

Page 50 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.1.3 Wiring method
Page 50 · click to enlarge
Page 50
1. Power supply wiring
  • Separate the GOT's power supply line from the lines for I/O devices and power devices as shown below. When there is much noise, connect an insulation transformer.

Power supply wiring diagram

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.1.3 Wiring method diagram (page 50)
Fig. 30 · 6.1.3 Wiring method
  • 100VAC, 200VAC and 24VDC wires should be twisted as dense as possible. Connect the modules with the shortest distance.

Also, to reduce the voltage drop to the minimum, use the thickest wires possible (0.75 to 2mm2). Use a solderless terminal for M3 screw. Also, be sure to tighten the M3 screw within tightening

  • torque 0.55 to 0.88 N m in order not to cause trouble.
  • Do not bundle the 100VAC, 200VAC and 24VDC wires with, or run them close to, the main circuit (high voltage, large current) and I/O signal lines. Reserve a distance of at least 100 mm from adjacent wires.
  • As a countermeasure to power surge due to lightening, connect a surge absorber for lightening as shown below.

Lightening surge absorber connection diagram

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.1.3 Wiring method diagram (page 50)
Fig. 31 · 6.1.3 Wiring method

(1) Separate the ground of the surge absorber for lightening (E1) from that of the

GOT (E2). (2) Select a surge absorber for lightening whose power supply voltage does no

exceed the maximum allowable circuit voltage even at the time of maximum power supply voltage elevation.

6. 6 6.1 GOT Main Unit 6.1.3 Wiring method
Page 51 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.1.3 Wiring method
Page 51 · click to enlarge
Page 51
2. Connection Cable Wiring
  • Do not bind connection cables with the main circuit (high voltage, heavy current) or I/O signal cables, or lay them close to each other.
  • When using A8GT-C EXSS-1 or A8GT-C BS, ground wires as below.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.1.3 Wiring method diagram (page 51)
Fig. 32 · 6.1.3 Wiring method

1) Connect the LG and FG terminals of GOT unit power to the ground through the terminal block with one wire. 2) Use FG wires of 28 cm or less for the A8GT-C BS cable. 3) Do not connect the FG grounding wire of A8GT-EXCNB cable. 4) Connect the A8GT-C BS cable's FG wire to FG of the GOT unit power terminal block. 5) Connect the A8GT-C BS cable's FG wire on the PLC side to FG of the PLC power supply module. 6) Connect the LG and FG terminals of the terminal block on the PLC to ground with one wire.

(2) When using A8GT-C BS cable

Connect the A8GT-C BS cable's FG wires on the both sides to the FG terminals on the power terminal block of the both side GOTs.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.1.3 Wiring method diagram (page 51)
Fig. 33 · 6.1.3 Wiring method

6.1 GOT Main Unit 6.1.3 Wiring method 6 - 7

Page 52 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.1.3 Wiring method
Page 52 · click to enlarge
Page 52
3. Grounding
  • For grounding, perform the following:

Use a dedicated grounding wire as far as possible. (Grounding resistance of 100 or less.) • When a dedicated grounding cannot be performed, use (2) Common Grounding shown below. Also, be sure to take noise countermeasures other than grounding.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.1.3 Wiring method diagram (page 52)
Fig. 34 · 6.1.3 Wiring method

(2) Common grounding Good (3) Joint grounding Not allowed

  • For grounding a cable, use the cable of 2 mm 2 or more. Position the ground-contact point as closely to the sequencer as possible, and reduce the length of the grounding cable as much as possible.

(a) An example of independent grounding

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.1.3 Wiring method diagram (page 52)
Fig. 35 · 6.1.3 Wiring method

* For control system grounding, apply single-point grounding for one system. Especially for the devices communicating each other, be sure to earth the grounding wire at one point.

(b) An example of common grounding

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.1.3 Wiring method diagram (page 52)
Fig. 36 · 6.1.3 Wiring method

Use a grounding wire as thick and short as possible.

* Apply single-point grounding for one system.

6. 8 6.1 GOT Main Unit 6.1.3 Wiring method
Page 53 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.1.3 Wiring method
Page 53 · click to enlarge
Page 53

(c) Recommended terminal shapes

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.1.3 Wiring method diagram (page 53)
Fig. 37 · 6.1.3 Wiring method
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.1.3 Wiring method diagram (page 53)
Fig. 38 · 6.1.3 Wiring method

6.1 GOT Main Unit 6.1.3 Wiring method 6 - 9

Page 54 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — (FG) INPUT 24VDC (FG) INPUT
Page 54 · click to enlarge
Page 54
4. Connecting to the GOT Power Section The following diagram shows the wiring example of power lines, grounding lines, etc. to the GOT power section.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.1.3 Wiring method diagram (page 54)
Fig. 39 · 6.1.3 Wiring method

(1) Use the thickest possible (max. 2 mm2 (14 AWG)) wires for the 100/200 VAC and

24 VDC power cables. Be sure to twist these wires starting at the connection terminals. To prevent a short-circuit should any screws loosen, use solderless terminals with insulation sleeves. (2) When the LG terminals and FG terminals are connected, be sure to ground the

wires. Do not connect the LG terminals and FG terminals to anything other than ground. If LG terminals and FG terminals are connected without grounding the wires, the PLC may be susceptible to noise. In addition, since the LG terminals have potential, the operator may receive an electric shock when touching metal parts.

How to wiring the GOT power supply section is explained below.

Wiring diagram of the A95*GOT Wiring diagram of the A956WGOT

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.1.3 Wiring method diagram (page 54)
Fig. 40 · 6.1.3 Wiring method
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.1.3 Wiring method diagram (page 54)
Fig. 41 · 6.1.3 Wiring method

(FG) INPUT 24VDC (FG) INPUT

6. 10 6.1 GOT Main Unit 6.1.3 Wiring method
Page 55 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.1.4 Installation of handy type GOT
Page 55 · click to enlarge
Page 55

6.1.4 Installation of handy type GOT

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.1.4 Installation of handy type GOT diagram (page 55)
Fig. 42 · 6.1.4 Installation of handy type GOT

The A950GOT can be used as a handy type, in addition to the conventional installation method.

RS-422 cable to connect the GOT and the computer link unit must be prepared by the user.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.1.4 Installation of handy type GOT diagram (page 55)
Fig. 43 · 6.1.4 Installation of handy type GOT

6.1 GOT Main Unit 6.1.4 Installation of handy type GOT 6 - 11

Page 56 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.1.4 Installation of handy type GOT
Page 56 · click to enlarge
Page 56
2. An internal diagram of the control panel is shown below.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.1.4 Installation of handy type GOT diagram (page 56)
Fig. 44 · 6.1.4 Installation of handy type GOT

Connector which can ground earth line to casing of connector

*1: Separately ground the power wire and signal wire.

*2: Power wire and the signal wire must separated by a separate shield and ground to FG.

3. Notes when cable is made.
  • The cable must be 200m or shorter.
  • When branching inside and outside the control panel, use a connector in between. The connector used must be able to attach the earthing to the connector casing.
  • When the cable is made, the terminal 24VDC of the connector on the GOT side is connected with the 24VDC power supply of the control board. Therefore, it should not be connected to the power supply terminal in the back of the main body of GOT.
6. 12 6.1 GOT Main Unit 6.1.4 Installation of handy type GOT
Page 57 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.2.2 Mounting procedure
Page 57 · click to enlarge
Page 57

6.2 Protective Sheet

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.2 Protective Sheet diagram (page 57)
Fig. 45 · 6.2 Protective Sheet

The protective sheet is used to protect the operation surface from scratches and contamination which may take place when the touch keys of the GOT display section are operated.

6.2.2 Mounting procedure

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.2.2 Mounting procedure diagram (page 57)
Fig. 46 · 6.2.2 Mounting procedure
1. From the display section of the GOT, peel off the sheet applied before shipment from the factory or the old protective sheet.
2. Peel off the release film of the new protective sheet and apply its adhesive surface to the display section of the GOT. When applying the protective sheet, exercise care not to make it loose and not to make gaps on the adhesive surface.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.2.2 Mounting procedure diagram (page 57)
Fig. 47 · 6.2.2 Mounting procedure

6.2 Protective Sheet 6.2.1 Protective sheet type 6 - 13

Page 58 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.3.2 Mounting procedure
Page 58 · click to enlarge
Page 58

6.3 Memory board (A956WGOT only)

The memory board is used to store the optional function OS program (ladder monitoring function, recipe function, speech output function, etc.) and to increase the built-in memory capacity.

6.3.1 Memory board types

The following memory board types are available.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.3.1 Memory board types diagram (page 58)
Fig. 48 · 6.3.1 Memory board types

A9GT-FNB1M For optional function OS storage + built-in memory extension, 1M byte

A9GT-FNB2M For optional function OS storage + built-in memory extension, 2M byte

A9GT-FNB4M For optional function OS storage + built-in memory extension, 4M byte

A9GT-FNB8M For optional function OS storage + built-in memory extension, 8M byte

For optional function OS storage + built-in memory extension, 4M byte

For optional function OS storage + built-in memory extension, 8M byte

*1 When using the ladder monitor function, use the A9GT-QFNB (4/8M).

*2 There are restrictions on the ROM_BIOS version of the GOT depending on the hardware version of the memory

board. However, the A956WGOT has no problems since it is installed with supported ROM_BIOS, starting with the

initial product.

6.3.2 Mounting procedure

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.3.2 Mounting procedure diagram (page 58)
Fig. 49 · 6.3.2 Mounting procedure
1. Open the slot cover on the back of the A956WGOT
2. Mount the memory board in the slot for mounting a memory board. Be careful not to touch the board inside the GOT main body by hand when mounting the memory board.
3. Fix by tightening the mounting screws of the memory board within the specified torque range.
4. Close the slot cover.
6. 14 6.3 Memory board (A956WGOT only) 6.3.1 Memory board types
Page 59 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.4.2 Mounting procedure
Page 59 · click to enlarge
Page 59

6.4 Memory Card Interface Module

The memory card interface module is connected to the GOT when the PC card is used with the GOT. The PC card is used to transfer the OS or monitor screen data or to store data using the alarm history func- tion, recipe function or other object function. Refer to the following manual for details of OS or monitor screen data transfer.

  • When GT Designer is used : GT Works Version /GT Designer Version Reference Manual
  • When GT Designer2 is used : GT Designer2 Version Operating Manual

Refer to the following manual for details of the alarm history function and recipe function.

  • When GT Designer is used : Help function of GT Designer
  • When GT Designer2 is used : GT Designer2 Version Reference Manual

6.4.1 Memory card interface module type

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.4.1 Memory card interface module type diagram (page 59)
Fig. 50 · 6.4.1 Memory card interface module type

The following memory card interface module type is available.

6.4.2 Mounting procedure

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.4.2 Mounting procedure diagram (page 59)
Fig. 51 · 6.4.2 Mounting procedure
1. Install the A1SD59J-MIF to the control cabinet, etc. 2) Plug the GOT side connector to the option unit at the bottom of the GOT.
  • For details of the A1SD59-MIF specifications, refer to the A1SD59J-MIF Memory Card Interface Module User's Manual (Hardware).
  • When a memory card interface unit is used, a compact flash PC card cannot be used. When using a memory card interface module, turn off the memory card access switch on the A956WGOT main body.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.4.2 Mounting procedure diagram (page 59)
Fig. 52 · 6.4.2 Mounting procedure

6.4 Memory Card Interface Module 6.4.1 Memory card interface module type 6 - 15

Page 60 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.4.4 Battery changing timing and method
Page 60 · click to enlarge
Page 60

6.4.3 PC card types

The PC card usable is any of the PC card having the following specifications (standard) whose operations have been checked by Mitsubishi.

  • Commercial SRAM type PC card conforming to PCMCIA ver. 2.1

6.4.4 Battery changing timing and method

(1) How to check for battery low The GOT checks for a battery low of the memory card loaded. (Only when the memory card access switch is ON)

The battery low checking methods are given below. 1) Using the self-diagnostic function to check When a battery low occurs, the corresponding message appears on the self-diagnostic screen. For the details, refer to the [GOT-A900 Series Operating Manual

(Extended Option Functions Manual)]. 2) Using the alarm list display (system alarm) function to check When a battery low occurs, the error warning message and battery low error code appear on the monitor screen. Refer to the following manual for details.

When GT Designer is usedHelp function of GT Designer
When GT Designer2 is usedGT Designer2 Version Reference Manual

(2) Battery life For the PC card backup time, refer to the instruction manual attached to the memory card used.

(3) Battery changing For the PC card battery changing method, refer to the instruction manual attached to the memory card used.

6. 16 6.4 Memory Card Interface Module 6.4.3 PC card types
Page 61 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.4.5 Loading and unloading procedures
Page 61 · click to enlarge
Page 61

6.4.5 Loading and unloading procedures

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.4.5 Loading and unloading procedures diagram (page 61)
Fig. 53 · 6.4.5 Loading and unloading procedures

The PC card can be loaded/unloaded while power is on. Note that the PC card should be loaded/unloaded after it has been made ready to be loaded/unloaded in the following procedures.

1. Set the memory card access switch of the A1SD59J-MIF to "OFF" and make sure that the memory card LED goes off. When the memory card LED goes off, the PC card can be loaded/unloaded while power is on.
2. When loading the PC card into the A1SD59J-MIF, insert and load it into the PC card interface with its top face up.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.4.5 Loading and unloading procedures diagram (page 61)
Fig. 54 · 6.4.5 Loading and unloading procedures
1. Set the memory card access switch of the A1SD59J-MIF to "OFF" and make sure that the memory card LED goes off. When the PC card LED goes off, the memory card can be loaded/unloaded while power is on.
2. Remove the PC card after fully pushing the memory card eject button of the A1SD59J-MIF to eject the PC card.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.4.5 Loading and unloading procedures diagram (page 61)
Fig. 55 · 6.4.5 Loading and unloading procedures

6.4 Memory Card Interface Module 6.4.5 Loading and unloading procedures 6 - 17

(2) Dismounting

Page 62 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.5.1 Compact flash PC card types
Page 62 · click to enlarge
Page 62

6.5 Compact flash PC card (A956WGOT only)

The Compact flash PC card is used to transfer the OS and monitor screen data and to store the data of the alarm history and recipe functions. Refer to the following manual for details of OS or monitor screen data transfer.

  • When GT Designer is used : GT Works Version /GT Designer Version Reference Manual
  • When GT Designer2 is used : GT Designer2 Version Operating Manual

Refer to the following manual for details of the alarm history function and recipe function.

  • When GT Designer is used :Help function of GT Designer
  • When GT Designer2 is used :GT Designer2 Version Reference Manual

6.5.1 Compact flash PC card types

The Compact flash PC card usable is any of the Compact flash PC card having the following specifications (standard) whose operations have been checked by Mitsubishi.

  • Commercial Compact flash PC card conforming to Compact flashTM. For the operation-confirmed models, refer to the separately available document "List of operation-confirmed devices for GOT900 series" (Technical bulletin T10-0028). When the document is necessary, please contact your local Mitsubishi representative. If the model used is not given in the document, it may not operate properly. The above document can be viewed on the Mitsubishi Electric FA Network Service On World Wide, MELFANSweb home page. (MELFANSweb home page: <a href="http://wwwf2.MitsubishiElectric.co.jp/melfansweb/english/" rel="nofollow noopener" target="_blank">http://wwwf2.MitsubishiElectric.co.jp/melfansweb/english/</a>)
6. 18 6.5 Compact flash PC card (A956WGOT only) 6.5.1 Compact flash PC card types
Page 63 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.5.2 Loading and unloading procedures
Page 63 · click to enlarge
Page 63

6.5.2 Loading and unloading procedures

The Compact flash PC card can be loaded/unloaded while power is on. Note that the Compact flash PC card should be loaded/unloaded after it has been made ready to be loaded/unloaded in the following procedures.

1. Set the compact flash card access switch of the GOT to "OFF" and make sure that the compact flash PC card LED goes off. When the compact flash PC card LED goes off, the compact flash PC card can be loaded/unloaded while power is on.
2. When loading the compact flash PC card into the GOT, insert and load it into the compact flash PC card interface with its top face up.

Compact flash card top face.

1. Set the compact flash PC card access switch of the GOT to "OFF" and make sure that the compact flash PC card LED goes off. When the compact flash PC card LED goes off, the compact flash PC card can be loaded/unloaded while power is on.
2. Remove the compact flash PC card after fully pushing the compact flash PC card ejection button of the GOT to eject the compact flash PC card.
  • When a memory card interface unit is used, a compact flash PC card cannot be used. When using a memory card interface module, turn off the memory card access switch on the GOT main body.

6.5 Compact flash PC card (A956WGOT only) 6.5.2 Loading and unloading procedures 6 - 19

(1) Mounting · (2) Dismounting · Push

Page 64 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.6.2 Mounting procedure
Page 64 · click to enlarge
Page 64

6.6 Communication Board (A956WGOT only)

The communication board is used to make the A956WGOT interface compatible with the system to be con- nected to. For the details of the connection form, refer to the [GOT-A900 Series User's Manual (Connection System Manual)].

6.6.1 Communication board types

The following connection board types are available.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.6.1 Communication board types diagram (page 64)
Fig. 56 · 6.6.1 Communication board types

A9GT-50WQBUSS For bus connection, small connector type (For QCPU (Q mode))

A9GT-50WBUSS For bus connection, small connector type (For A/QnA/Motion controller CPU)

A9GT-50WRS4 For Direct connection to CPU/Computer link connection/Microcomputer connection and RS-422 connection

A9GT-50WRS2 For Direct connection to CPU/Computer link connection/Microcomputer connection and RS-232C connection

6.6.2 Mounting procedure

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.6.2 Mounting procedure diagram (page 64)
Fig. 57 · 6.6.2 Mounting procedure
1. Open the slot cover on the back of the A956WGOT.
2. Mount the communication board in the slot for mounting a communication board. (Align the hole for the attachment screw on the transmission board with the hole for the attachment screw on the transmission board of the GOT main module, then attach.)
3. Fix by tightening the mounting screws of the communication board within the specified torque range.
4. Close the slot cover.
6. 20 6.6 Communication Board (A956WGOT only) 6.6.1 Communication board types
Page 65 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A9GT-BUS2SU
Page 65 · click to enlarge
Page 65
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.7 Communication Module (A956GOT, A956WGOT Only) diagram (page 65)
Fig. 58 · 6.7 Communication Module (A956GOT, A956WGOT Only)

The communication module is used to make the A956GOT, A956WGOT interface compatible with the sys- tem to be connected to. For the details of the connection form, refer to the [GOT-A900 Series User's Manual (Connection System Manual)].

6.7.1 Connection module types

The following connection module types are available.

A9GT-QBUS2SU For multidrop bus connection, small connector type (For QCPU (Q mode))

A9GT-BUSSU

For bus connection, small connector type (For A/QnA/Motion controller CPU) A7GT-BUSS *1 *2

A9GT-BUS2SU

For multidrop bus connection, small connector type (For A/QnA/Motion controller CPU) A7GT-BUS2S *1 *2

A7GT-J71AP23 For MELSECNET(II) optical link connection, for use as local station

A7GT-J71AR23 For MELSECNET(II) coaxial link connection, for use as local station

A7GT-J71AT23B For MELSECNET/B connection, for use as local station

A9GT-QJ71LP23 For MELSECNET/10 optical loop network connection, for use as ordinary station *3

A9GT-QJ71BR13 For MELSECNET/10 coaxial bus network connection, for use as ordinary station *3

A7GT-J71LP23 For MELSECNET/10 optical loop network connection, for use as ordinary station *3

A7GT-J71BR13 For MELSECNET/10 coaxial bus network connection, for use as ordinary station *3

A8GT-J61BT13 For CC-Link connection, for use as intelligent device station

A8GT-J61BT15 For CC-Link connection, for use as remote device station

A9GT-J71E71-T For Ethernet connection

*1 The A956WGOT cannot be used.

*2 When using the A7GT-BUSS or A7GT-BUS2S, the module hardware version must be version B or above.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — A9GT-BUS2SU diagram (page 65)
Fig. 59

Confirm the hardware version of the unit stamped on the rating plate of the product.

*3 For the A9GT-QJ71LP23 and A9GT-QJ71BR13, the device range (QCPU, QnACPU, ACPU) that can be monitored

When the A7GT-J71LP23 or A7GT-J71BR13 is mounted, only the device range of the AnA can be monitored.

For details, refer to the GOT-A900 Series User's Manual (Connection).

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — A9GT-BUS2SU diagram (page 65)
Fig. 60

6.7 Communication Module (A956GOT, A956WGOT Only) 6.7.1 Connection module types 6 - 21

Type Description

Page 66 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.7.2 Mounting procedure
Page 66 · click to enlarge
Page 66

6.7.2 Mounting procedure

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.7.2 Mounting procedure diagram (page 66)
Fig. 61 · 6.7.2 Mounting procedure
1. Fit the communication module securing fixtures in the GOT main unit.
2. Mount the communication module on the GOT interface.
3. Tighten and fix the mounting screws (3 pcs.) of the communication module in the specified torque range.
6. 22 6.7 Communication Module (A956GOT, A956WGOT Only) 6.7.2 Mounting procedure
Page 67 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A9GT-J71E71-T
Page 67 · click to enlarge
Page 67

The following software packages are required to use the communication module.

A9GT-QBUS2SU

SW0D5C-GTWORKS-E Version A or later

SW3D5C-GOTRE-PACK Version A or later A7GT-BUSS

SW1D5C-GTWK2-E Version A or later

A9GT-BUSSU

SW1D5C-GTD2-E Version A or later

A7GT-BUS2S

A9GT-BUS2SU

A7GT-J71AP23

A7GT-J71AR23

SW1D5C-GTWK2-E Version A or later

A7GT-J71AT23B

SW1D5C-GTD2-E Version A or later

A7GT-J71LP23

SW0D5C-GTWORKS-E Version A or later *1

A7GT-J71BR13

SW3D5C-GOTRE-PACK Version A or later *1

SW1D5C-GTWK2-E Version A or later *1

A9GT-QJ71LP23

SW1D5C-GTD2-E Version A or later *1

A9GT-QJ71BR13

SW1D5C-GTWK2-E Version K or later *2

SW1D5C-GTD2-E Version K or later *2

A8GT-J61BT13

A8GT-J61BT15

SW1D5C-GTWK2-E Version A or later

SW1D5C-GTD2-E Version A or later

SW5D5C-GTWORKS-E Version P or later *3

A9GT-J71E71-T

SW5D5C-GOTRE-PACK Version P or later *3

*1 The device range of the AnA can be monitored.

*2 The device ranges of the QCPU, QnACPU and ACPU can be monitored.

*3 When using the A9GT-J71E71-T whose hardware version is Version E or later, use Version 26C or later. (Cannot be

used for Version P to Version Y.)

6.7 Communication Module (A956GOT, A956WGOT Only) 6.7.2 Mounting procedure 6 - 23

Show 6 more labels / short text on this page
Compatible software packages · Model name · GT Works 2 · GT Works · GT Designer 2 · GT Designer
Page 68 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.8.2 How to connect the printer interface module
Page 68 · click to enlarge
Page 68

6.8 Printer Interface Module

The printer interface module is connected to the GOT when the printer is used with the GOT. The printer is used to print the data and others of the alarm history and hard copy functions. Refer to the following manual for details of the corresponding functions.

  • When GT Designer is used : Help function of GT Designer
  • When GT Designer2 is used : GT Designer2 Version Reference Manual

6.8.1 Printer interface module type

The following printer interface module type is available.

A9GT-50PRF Printer interface module

6.8.2 How to connect the printer interface module

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.8.2 How to connect the printer interface module diagram (page 68)
Fig. 62 · 6.8.2 How to connect the printer interface module
1. Thread A9GT-50PRF mounting screw holes in the control

box or the like. (2- 3.5 mounting holes) The A9GT-50PRF's GOT connection cable is 50cm long. Install the A9GT-50PRF within this distance so that the GOT-end connector of the cable may be fitted into the GOT's connector. When mounting the A9GT-50PRF on the back of control box door, exercise care to avoid screw holes passing through the control box surface. 2) Tighten the mounting screw to the specified torque range 39 to 59N cm.

3. Plug the GOT side connector of the A9GT-50PRF to the option unit at the bottom of the GOT. For A95 GOT
  • For details of the printer interface module specifications, refer to the A9GT-50PRF type printer interface module User's Manual.
6. 24 6.8 Printer Interface Module 6.8.1 Printer interface module type

Type Description

Page 69 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.8.4 Connecting procedure
Page 69 · click to enlarge
Page 69

6.8.3 Printer types

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.8.3 Printer types diagram (page 69)
Fig. 63 · 6.8.3 Printer types

The printer usable is any of the printers having the following specifications (standard) whose operations have been checked by Mitsubishi.

  • ESC/P24-J84-compliant printer (ESC/P command-compatible, color-compatible)
  • Hewlett Packard printers (PLC command compatible) For the operation-confirmed models, refer to the separately available document "List of operation-confirmed devices for GOT900 series" (Technical bulletin T10-0028). When the document is necessary, please contact your local Mitsubishi representative. If the printer used is not given in the document, it may not operate properly. The above document can be viewed on the Mitsubishi Electric FA Network Service On World Wide, MELFANSweb home page. (MELFANSweb home page: <a href="http://wwwf2.MitsubishiElectric.co.jp/melfansweb/english/" rel="nofollow noopener" target="_blank">http://wwwf2.MitsubishiElectric.co.jp/melfansweb/english/</a>)

6.8.4 Connecting procedure

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.8.4 Connecting procedure diagram (page 69)
Fig. 64 · 6.8.4 Connecting procedure
1. Plug the GOT side connector of the printer cable to the parallel interface of the A9GT-50PRF. 2) Connect the A9GT-50PRF and printer by the printer cable.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.8.4 Connecting procedure diagram (page 69)
Fig. 65 · 6.8.4 Connecting procedure

6.8 Printer Interface Module 6.8.3 Printer types 6 - 25

Page 70 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.9.2 Mounting procedure
Page 70 · click to enlarge
Page 70

6.9 External I/O Module

The external I/O module is connected with the ten-key panel (A8GT-TK) or keyboard to receive up to 8/64 points of inputs or provide up to 16 points of outputs. Refer to the following manual for details of the corresponding functions.

  • When GT Designer is used : Help function of GT Designer
  • When GT Designer2 is used : GT Designer2 Version Reference Manual

6.9.1 External I/O module type

The following external I/O module is available.

A8GT-50KBF External I/O module

6.9.2 Mounting procedure

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.9.2 Mounting procedure diagram (page 70)
Fig. 66 · 6.9.2 Mounting procedure
1. Thread A8GT-50KBF mounting screw holes in the control

box or the like. (2- 3.5 mounting holes) The A8GT-50KBF's GOT connection cable is 50cm long. Install the A8GT-50KBF within this distance so that the GOT-end connector of the cable may be fitted into the GOT's connector. When mounting the A8GT-50KBF on the back of control box door, exercise care to avoid screw holes passing through the control box surface.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.9.2 Mounting procedure diagram (page 70)
Fig. 67 · 6.9.2 Mounting procedure
2. Tighten the mounting screws to the specified torque range 39 to 59N cm. 3) Plug the GOT side connector of the A8GT-50KBF to the option unit of the GOT.
  • When using the A8GT-50KBF, use the ROM_BIOS of SW1D5C-GOTRE-PACK H version or later (ROM_BIOS G version or later). (GT Works2 and GT Designer2 are compatible, starting with the initial products (Version 1.00A).)
  • For details of the External I/O module specifications, refer to the A8GT-50KBF type External I/O module User's Manual.
6. 26 6.9 External I/O Module 6.9.1 External I/O module type

Type Description

Page 71 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.10.2 Connecting procedure
Page 71 · click to enlarge
Page 71

6.10 Bar Code Reader

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.10 Bar Code Reader diagram (page 71)
Fig. 68 · 6.10 Bar Code Reader

The bar code reader is used for writing data that is read with the bar code reader into the programmable con- troller CPU. Refer to the following manual for details of the bar code function.

  • When GT Designer is used : Help function of GT Designer
  • When GT Designer2 is used : GT Designer2 Version Reference Manual

The bar-code reader, which has been confirmed to operate properly by Mitsubishi Electric, can be used. For the operation-confirmed models, refer to the separately available document "List of operation-confirmed devices for GOT900 series" (Technical bulletin T10-0028). When the document is necessary, please contact your local Mitsubishi representative. If the bar-code reader used is not given in the document, it may not operate properly. The above document can be viewed on the Mitsubishi Electric FA Network Service On World Wide, MEL- FANSweb home page. (MELFANSweb home page: http://wwwf2.MitsubishiElectric.co.jp/melfansweb/english/)

6.10.2 Connecting procedure

1. To the RS-232C interface of the GOT, choose and connect one from the following: the connector for the bar code reader; the connector for the power supply module; and the connector on the GOT for the RS-232C cable. (The connecting method differs depending on the kind of bar code reader that will be used.)
  • Please note that the bar code reader cannot be used if the GOT is connected to the MELSECNET/B or MELSECNET II.
  • The power supply (5V DC) needs to be supplied from an AC-DC adapter or a corresponding power module to the bar code reader.
  • The RS-232C cable needs to be prepared by the user of this product. For details of preparations of the cable, please refer to the ["List of operation-confirmed devices for GOT900 series" (Technical bulletin T10-0028)]
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.10.2 Connecting procedure diagram (page 71)
Fig. 69 · 6.10.2 Connecting procedure

6.10 Bar Code Reader 6.10.1 Bar code reader types 6 - 27

For A95 GOT · For A956WGOT

Page 72 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 6.11.2 Mounting procedure
Page 72 · click to enlarge
Page 72

6.11 Debug Stand

The debug stand is used to secure the GOT in a standing position so that the monitor screen data may be debugged easily.

6.11.1 Debug stand type

The following debug stand type is available.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.11.1 Debug stand type diagram (page 72)
Fig. 70 · 6.11.1 Debug stand type

6.11.2 Mounting procedure

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.11.2 Mounting procedure diagram (page 72)
Fig. 71 · 6.11.2 Mounting procedure
1. Adjust the GOT mounting angle with the angle adjusting fixture of the debug stand. 2) Put the GOT into the front face of the debug stand and mount it on the debug stand with the mounting fixtures of the GOT main unit. Refer to [Section 6.1.2] for the installation method using the mounting fixtures of the GOT main unit.

Adjust at 45 , 55 , 65 or 75

  • For details of the debug stand specifications, refer to the A9GT-50STAND User's Manual or A9GT-50WSTAND User's Manual.
6. 28 6.11 Debug Stand 6.11.1 Debug stand type
Page 73 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A95 GOT
Page 73 · click to enlarge
Page 73

6.12 Attachment (A95*GOT only)

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.12 Attachment (A95*GOT only) diagram (page 73)
Fig. 72 · 6.12 Attachment (A95*GOT only)

The attachment is used to replace the A85*GOT with the A95*GOT. By the use of the attachment, additional machining to the installation hole in the control panel of the A85*GOT can be eliminated.

6.12.1 Attachment type

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 6.12.1 Attachment type diagram (page 73)
Fig. 73 · 6.12.1 Attachment type

6.12.2 Mounting procedure

1. Peel off the pressure sensitive adhesive double coated tape from the rear surface of the attachment.
2. Install the attachment securely taking care so that it is positioned correctly in the installation panel mounting hole. If the installation panel is dirty, the attachment may fall, causing injury. Ensure to clean the installation panel by wiping it off before installation of the attachment.
3. Insert the GOT main unit from the front of the attachment, and tighten it to the specified torque using the mounting screws furnished with the GOT main unit.

A95 GOT

  • The attachment can be used when the plate thickness of the installation panel is 1.2 (0.05) to 3 mm (0.12 in). When the plate thickness exceeds 3 mm (0.12 in), the attachment cannot be used for the replacement of the GOT.
  • Once the GOT has been replaced with a new GOT by the use of the attachment, the new GOT does not meet the requirements specified in the standards for water and dust resistance IP65/ IP67/NEMA4.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — A95 GOT diagram (page 73)
Fig. 74

6.12 Attachment (A95*GOT only) 6.12.1 Attachment type 6 - 29

Installation panel · Attachment · Installation panel

Page 74 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — CAUTION
Page 74 · click to enlarge
Page 74

7 MAINTENANCE AND INSPECTION

This chapter explains the items which should be performed daily or periodically to use the GOT to its opti- mum.

7.1 Instructions for Maintenance and Inspection

The following instructions should be observed for maintenance and inspection.

When power is on, do not touch the terminals. Doing so can cause an electric shock or malfunction. Before starting cleaning or terminal screw retightening, always switch off the power externally in all phases. Not switching the power off in all phases can cause a module failure or malfunction. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or module. Before changing the backlight, always turn the GOT power OFF (When using a GOT bus connection, also turn OFF the PLC CPU power), and remove the GOT main unit from the panel before changing the backlight. Not switching the power off in all phases may cause an electric shock. Not removing the unit from the enclosure can cause injury due to a drop.

DANGER

Do not disassemble or modify the module. Doing so can cause a failure, malfunction, injury or fire. Do not touch the conductive and electronic parts of the module directly. Doing so can cause a module malfunction or failure. The cables connected to the module must be run in ducts or clamped. Not doing so can cause the module or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault. When unplugging the cable connected to the module, do not hold and pull the cable portion. Doing so can cause the module or cable to be damaged or can cause a malfunction due to a cable connection fault. When disposing of the product, handle it as industrial waste. While changing the backlight, do not touch the circuit boards and electronic parts of the GOT. Doing so can cause a failure or malfunction. When replacing the backlight, use the gloves. Otherwise, it may cause you to be injured. If you should directly touch the plated area of the main unit case with hand, be sure to wipe off the fingerprint and so on, and install the main unit case. Otherwise, it may cause a trouble or malfunction. Start changing the backlight more than 5 minutes after switching the GOT power off. Not doing so can cause a burn due to the heat of the backlight.

CAUTION

7. 1 7.1 Instructions for Maintenance and Inspection
Page 75 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 24VDC
Page 75 · click to enlarge
Page 75

7.2 Daily Inspection

Daily inspection items are as follows.

Number Inspection Item Inspection Method Criterion Action

Check for loose mounting

1 Module mounting status

Securely mounted Retighten screws

Retighten screws with screw-

Not loose Retighten terminal screws

Visual check Proper intervals Correct

Visual check Not loose

7.3 Periodic Inspection

Inspection items to be checked once or twice in six months or one year are as follows. The following inspection should also be performed when equipment has been moved or modified or the wir- ing changed.

Number Inspection Item Inspection Method Criterion Action

tion 0 to 40

perature Make measurement with ther-

For use in enclosure, tempera-

Other portions 0 to 55

ture inside enclosure is ambi-

Atmosphere No corrosive gas

24VDC

2 Power supply voltage check

Measure voltage across termi-

20.4DC to 26.4V Change supply power

Looseness Move module Should be mounted firmly Retighten screws

Visual check No dirt, foreign matter sticking Remove, clean

Retighten screws with screw-

Not loose Retighten terminal screws

Visual check Proper intervals Correct

Visual check Not loose

7.2 Daily Inspection 7 - 2

Show 41 more labels / short text on this page
screws and disconnected · cover · Loose termi- · nal screws · driver · Proximate · 2 Connection · solderless ter- · status · minals · Loose con- · Retighten connector fixing · nectors · screws · Display sec- · Ambient tem- · 1 Surrounding · mometer or hygrometer · environment · Ambient · Measure corrosive gas · 10 to 90%RH · ent temperature · humidity · nals · 3 Mounting sta- · tus · Dirt, foreign · matter · Loose termi- · nal screws · driver · Proximate · 4 Connection · solderless ter- · status · minals · Loose con- · Retighten connector fixing · nectors · screws
Page 76 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 7.4 How to Change the Backlight for Liquid Crystal
Page 76 · click to enlarge
Page 76

7.4 How to Change the Backlight for Liquid Crystal

The A95*GOT-TBD(-M3), A95*GOT-SBD(-M3)-B and A956WGOT do not require their backlights to be replaced since they are installed with long-life backlights.

The GOT contains a backlight for the liquid crystal of the display device. The luminance of the back light lowers as it is used. Change the backlight if the screen of the display device has become difficult to look at due to the reduced luminance of the backlight. Change the backlight in the following procedure.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 7.4 How to Change the Backlight for Liquid Crystal diagram (page 76)
Fig. 75 · 7.4 How to Change the Backlight for Liquid Crystal
1. Turn the GOT’s power off. Remove the wire from the power supply terminal and also remove the communications cable. When using the A956GOT, remove the network module.
2. After loosening the mounting fixtures of the GOT, remove the GOT from the enclosure.
3. Remove the fixing screws (2 pcs.) in the back of the GOT with a screwdriver.
4. Remove the case on the back of the GOT.
7. 3 7.4 How to Change the Backlight for Liquid Crystal
Page 77 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — [Disposal Instructions]
Page 77 · click to enlarge
Page 77
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 7.4 How to Change the Backlight for Liquid Crystal diagram (page 77)
Fig. 76 · 7.4 How to Change the Backlight for Liquid Crystal
5. Unplug the cable connector of the backlight from the connector of the display device.
6. Remove the backlight from the display device. Using a flat-blade screwdriver makes removal easy.
7. Fit a new backlight in the reverse procedure of removal. To install the display unit, please follow the procedure reverse to that for removing. Please make sure to install the display unit securely and apply a torque within the torque range as specified to the fixing screws for the GOT.

When you push the screwdriver into the hole in the unit side, the backlight comes off.

* When changing the backlight, use care not to touch the circuit board in the GOT.

[Disposal Instructions]

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — [Disposal Instructions] diagram (page 77)
Fig. 77 · [Disposal Instructions]

To dispose of, please treat the back light as an industrial waste.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — [Disposal Instructions] diagram (page 77)
Fig. 78 · [Disposal Instructions]

7.4 How to Change the Backlight for Liquid Crystal 7 - 4

Page 78 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 8.1 Requirements for conformance to EMC Directive
Page 78 · click to enlarge
Page 78

For the products sold in European countries, the conformance to the EMC Directive, which is one of the European Directives, has been a legal obligation since 1996. Also, conformance to the Low Voltage Direc- tive, another European Directives, has been a legal obligation since 1997. Manufacturers who recognize their products must conform to the EMC and Low Voltage Directives required to declare that their products conform to these Directives and put a "CE mark" on their products.

Products that the EMC directive applies to are marked with the CE mark logo.

8.1 Requirements for conformance to EMC Directive

The EMC Directive specifies that products placed on the market must "be so constructed that they do not cause excessive electromagnetic interference (emissions) and are not unduly affected by electromagnetic interference (immunity)". The applicable products are requested to meet these requirements. The sections 8.1.1 through 8.3.3 sum- marize the precautions on conformance to the EMC Directive of the machinery constructed using the GOT. The details of these precautions has been prepared based on the requirements and the applicable standards control. However, we will not assure that the overall machinery manufactured according to these details con- forms to the above-mentioned directives. The method of conformance to the EMC directive and the judg- ment on whether or not the machinery conforms to the EMC Directive must be determined finally by the manufacturer of the machinery.

8. 1 8.1 Requirements for conformance to EMC Directive
Page 79 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 20.4V, 26.4V
Page 79 · click to enlarge
Page 79

8.1.1 Standards applicable to the EMC directive

Specification Test item Test details Standard value

30M-230MHz QP:

EN55011

Electromagnetic emissions from the

30dB V/m(30m measurement range) *2, *3

product are measured.

230M-1000MHz QP:

37dB V/m(30m measurement range) *2, *3

150k-500kHz QP79db,

Electromagnetic emissions from the

EN55011

Mean66dB *2

product to the power line are mea-

500k-30MHz QP73dB,

sured.

Mean60dB *2

Immunity test in which static electric-

EN61000-4-2

ity is applied to the cabinet of the

equipment.

EN61000-4-3

80-1000MHz10V/m

Immunity test in which field is irradi-

Radiated field AM modu-

1.4-2GHz10V/m

ated to the product.

80%AM modulation @ 1kHz

Power line2kV

EN61000-4-4

Immunity test in which burst noise is

Digital I/O (24V or more)1kV

Fast transient burst noise

applied to the power line and signal

(Digital I/O (24V or less)) 250V

lines.

EN61131-2 :

(Analog I/O, signal lines) 250V

EN61000-4-5

Immunity test in which lightening

Power line (between line and ground): 0.5kV

surge is applied to the product.

Data communication port0.5kV

EN61000-4-6

Immunity test in which a noise

Power line3V

inducted on the power and signal

Data communication port3V

lines is applied.

Test for checking normal operations

ure and voltage dips

at instantaneous power failure

10ms (interval 1s or more)

Test for checking normal operations

when the power supply unit input

20.4V, 28.8V

Test for checking if the unit becomes

faulty with a transient voltage of the

internal and external input sides of

20.4V, 26.4V

the power supply unit or unit power

*1 The GOT is an open type device (device installed to another device) and must be installed in a conductive control

panel. The above test items are conducted in the condition where the GOT is installed on the conductive control

panel and combined with the Mitsubishi PLC.

*2 QPQuasi-peak value, Mean: Average value

*3 The above test items are conducted in the following conditions.

30-230MHz QP :40dB þV/m (10m in measurement range)

230-1000MHz QP:47dB þV/m (10m in measurement range)

8.1 Requirements for conformance to EMC Directive 8.1.1 Standards applicable to the EMC directive 8 - 2

Show 21 more labels / short text on this page
Radiated noise *1 · Conducted noise *1 · 4kV Contact discharge · Electrostatic immunity *1 · 8kV Aerial discharge · lation *1 · *1 · DC power type · Surge immunity *1 · Conducted RF immunity · *1 · Instantaneous power fail- · DC power type · immunity · DC power type · Radiated RF immunity · voltage is fluctuated · External power supply · DC power type · fluctuation immunity · supply
Page 80 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 8.1.2 Control cabinet
Page 80 · click to enlarge
Page 80

8.1.2 Control cabinet

The GOT is an open type device (device installed to another device) and must be installed in a conductive control panel or cabinet. It not only assure the safety but also has a large effect to shut down the noise generated from GOT, on the control panel.

(a) Use a conductive control cabinet.

(b) When attaching the control cabinet's top plate or base plate, mask painting and weld so that

good surface contact can be made between the cabinet and plate.

(c) To ensure good electrical contact with the control cabinet, mask the paint on the installation bolts of the inner plate in the control cabinet so that contact between surfaces can be ensured over the widest possible area.

(d) Earth the control cabinet with a thick wire so that a low impedance connection to ground can

be ensured even at high frequencies. (22mm2 wire or thicker is recommended.)

(e) Holes made in the control cabinet must be 10 cm (3.94in.) diameter or less. If the holes are

10cm (3.94in.) or larger, radio frequency noise may be emitted. In addition, because radio waves leak through a clearance between the control panel door and the main unit, reduce the clearance as much as practicable. The leakage of radio waves can be suppressed by the direct application of an EMI gasket on the paint surface. Our tests have been carried out on a panel having the damping characteristics of 37 dB max. and 30 dB mean (measured by 3 m method with 30 to 300 MHz).

(2) Connection of power and ground wires Ground and power supply wires for the GOT must be connected as described below.

(a) Provide an earthing point near the GOT. Earth the power supply's FG terminal (FG: Frame

Ground) with the thickest and shortest wire possible. (The wire length must be 30cm (11.18in.) or shorter.) The FG terminal function is to pass the noise generated in the GOT to the ground, so an impedance that is as low as possible must be ensured. As the wires are used to relieve the noise, the wire itself carries a large noise content and thus short wiring means that the wire is prevented from acting as an antenna.

8. 3 8.1 Requirements for conformance to EMC Directive 8.1.2 Control cabinet

(1) Control cabinet

Page 81 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 8.1.3 Grounding
Page 81 · click to enlarge
Page 81

(3) Electrical shock prevention In order to such as the operators from electric shocks, the control box must have the following functions :

(a) The control cabinet must be equipped with a lock so that only skilled or qualified personnel.

(b) The control cabinet must be fitted with advice which automatically stops the power supply

when the cabinet is opened.

(4) Dustproof and waterproof features The control box also has the dustproof and waterproof functions. Insufficient dustproof and waterproof features lower the insulation withstand voltage, resulting in insulation destruction. The insulation in our GOT is designed to cope with the pollution level 2, so use in an environment with pollution level 2 or better.

Pollution level 1: An environment where the air is dry and conductive dust does not exist.

Pollution level 2: An environment where conductive dust does not usually exist, but occasional temporary conductivity occurs due to the accumulated dust. Generally, this is the level for inside the control box equivalent a control room or on the floor of a typical factory.

Pollution level 3: An environment where conductive dust exits and conductivity may be generated due to the accumulated dust. An environment for a typical factory floor.

Pollution level 4 : Continuous conductivity may occur due to rain, snow, etc. An outdoor environment.

8.1.3 Grounding

It is necessary to use the GOT grounding terminal only when it is in the grounded condition. Be sure to ground the grounding for the safety reasons and EMC Directives.

Functional grounding : Improves the noise resistance.

8.1 Requirements for conformance to EMC Directive 8.1.3 Grounding 8 - 4

Page 82 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 8.2.1 Overall configuration
Page 82 · click to enlarge
Page 82

8.2 System Configuration when EMC Directive is Applicable

Connection conditions and models where the EMC directive is applicable are shown below.

8.2.1 Overall configuration

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.2.1 Overall configuration diagram (page 82)
Fig. 79 · 8.2.1 Overall configuration

Option module*2 Printer interface module External I/O interface module Memory card interface module

Communication cable*1 For A950GOT RS-422 cable For A951GOT Bus connection cable For A953GOT RS-232C cable

Bus connection module CC-Link communication module Ethernet communication module

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.2.1 Overall configuration diagram (page 82)
Fig. 80 · 8.2.1 Overall configuration

Option module*2 Printer interface module External I/O interface module Memory card interface module

Communication module*1 Bus connection module CC-Link communication module Ethernet communication module Communication board*1 Bus connection board Serial communication board

Connection cable*1 Bus connection cable CC-Link dedicated cable Twisted pair shielded cable RS-232C cable RS-422 cable

*1 See section 8.2.3 for information about models and hardware versions that are applicable to the EMC directive.

*2 EMC directive is not applicable when using an option module.

8. 5 8.2 System Configuration when EMC Directive is Applicable 8.2.1 Overall configuration

(1) For A95*GOT · (2) For A956WGOT

Page 83 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 8.2.2 About modules applicable to the EMC directive
Page 83 · click to enlarge
Page 83

8.2.2 About modules applicable to the EMC directive

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.2.2 About modules applicable to the EMC directive diagram (page 83)
Fig. 81 · 8.2.2 About modules applicable to the EMC directive

The following table lists the modules compliant with the EMC directive.

: Compliant with EMC directive : Not compliant with EMC directive

(Built-in bus communication interface for Q CPU (Q mode))

*1 Be aware that if using A950GOT after removing the control panel as described in item 6.1.4, it is not applicable to the EMC directive.

If connecting to a PLC not from this company (MELSEC-Q series, MELSEC-QnA series, MELSEC-A series), refer to the manual of the connected device (PLC, microcomputer) for information about the applicability of the EMC directive

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.2.2 About modules applicable to the EMC directive diagram (page 83)
Fig. 82 · 8.2.2 About modules applicable to the EMC directive

8.2 System Configuration when EMC Directive is Applicable 8.2.2 About modules applicable to the EMC directive 8 - 6

Page 84 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 8.2.4 When the communication/board module is used
Page 84 · click to enlarge
Page 84

8.2.3 Connection format

Connection conditions where the A95*GOT is applicable to the EMC directive are shown below.

: Not compliant with EMC directive -: Connection impossible

Connection format A950GOT A951GOT-Q A951GOT A953GOT A956GOT A956WGOT

QCPU - - -

QnA/ACPU - - L(0105) - K(0105) E(0203)

QCPU

- - - L(0105) - E(0203)

(RS-232C)

L(0105) - - - - E(0203)

(RS-422)

RS-232C - - - L(0105) - E(0203)

RS-422 L(0105) - - - - E(0203)

MELSECNET connection -

Intelligent device - K(0105) E(0203)

- K(0105)

Ethernet connection - P(0203) E(0203)

The table indicates the GOT-compatible hardware version for each connection pattern and the compatibility date. Please use the GOT whose hardware version is later than that described.

L (0105)

Year (Last 2 digits of A.D. year)

8.2.4 When the communication/board module is used

(1) For A956GOT Be sure to use the communication modules shown below with A956GOT. If communication modules other than those shown below are used, they are not applicable to the EMC directive.

Connection format Communication module

A9GT-BUSS (Hardware version C or later)

A9GT-BUS2S (Hardware version C or later)

Intelligent device A8GT-J61BT13 (Hardware version E or later)

Remote device A8GT-J61BT15 (Hardware version C or later)

Ethernet connection A9GT-J71E71-T (Hardware version C or later)

8. 7 8.2 System Configuration when EMC Directive is Applicable 8.2.3 Connection format
Show 16 more labels / short text on this page
Bus Connection · CPU direct con- · nection · QnA/ACPU · Computer link · connection · CC-Link connec- · Remote device sta- · tion · tion · Compatibility date · (0105) · Month · Hardware version · Bus connection (QnA/ACPU) · CC-Link connection
Page 85 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 8.2.5 About the cable used
Page 85 · click to enlarge
Page 85

(2) For A956WGOT Be sure to use the communication boards/communication modules shown below with A956WGOT. If communication modules/communication boards other than those shown below are used, they are not applicable to the EMC directive.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.2.5 About the cable used diagram (page 85)
Fig. 83 · 8.2.5 About the cable used

Confirm the hardware version with the products rating plate.

(Products that the EMC directive applies to are marked with the CE mark logo.)

If making the GOT applicable to the EMC directive, be sure to use the cables shown below.

: EMC directive applicable : EMC directive not applicable

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.2.5 About the cable used diagram (page 85)
Fig. 84 · 8.2.5 About the cable used

To make applicable to the EMC directive, each cable (including user created cables) must be manufactured.

Refer to section 8.3.2 for the cable manufacturing method.

8.2 System Configuration when EMC Directive is Applicable 8.2.5 About the cable used 8 - 8

Page 86 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 8.3.1 Method to connect the power wire and ground wire
Page 86 · click to enlarge
Page 86

8.3 Wiring Precautions the Part which Matches the EMC Directives

Connect and wire GOT equipment as instructed below.

If the GOT equipment is configured in a way that differs from the following instructions

then the system will not comply with EMC directives.

8.3.1 Method to connect the power wire and ground wire

(1) With the power wire, be sure to attach the ferrite core (TDK type ZCAT3035-1330) within 90 mm of the GOT terminal module. Lead the power wire and ground wire as shown in Section 8.1.2 (2). Always ground the FG wires.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.1 Method to connect the power wire and ground wire diagram (page 86)
Fig. 85 · 8.3.1 Method to connect the power wire and ground wi…

*1 Wrap the power wire around the ferrite core.

8. 9 8.3 Wiring Precautions the Part which Matches the EMC Directives 8.3.1 Method to connect the power wire and ground wire
Page 87 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 8.3 Wiring Precautions the Part which Matches the EMC Directives
Page 87 · click to enlarge
Page 87

(a) When connecting CC-Link, use the grounding wire of the FG1 terminal on the CC-Link

communication module to connect to the FG terminal of the GOT power section. Use a grounding wire of 300 mm or less.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3 Wiring Precautions the Part which Matches the EMC Directives diagram (page 87)
Fig. 86 · 8.3 Wiring Precautions the Part which Matches the EM…
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3 Wiring Precautions the Part which Matches the EMC Directives diagram (page 87)
Fig. 87 · 8.3 Wiring Precautions the Part which Matches the EM…
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3 Wiring Precautions the Part which Matches the EMC Directives diagram (page 87)
Fig. 88 · 8.3 Wiring Precautions the Part which Matches the EM…

Use a CE compatible product for 24 V DC external common power source for GOT. The EMC test run by our company was confirmed with the same panel components as the DENSEI-LAMBDA type JWS 50-24 or DLP120-24-1 installed.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3 Wiring Precautions the Part which Matches the EMC Directives diagram (page 87)
Fig. 89 · 8.3 Wiring Precautions the Part which Matches the EM…

8.3 Wiring Precautions the Part which Matches the EMC Directives 8.3.1 Method to connect the power wire and ground wire 8 - 10

Page 88 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 8.3.2 Grounding the ground cable
Page 88 · click to enlarge
Page 88

8.3.2 Grounding the ground cable

Manufacture the cable used with the GOT with the following method. When manufacturing the cable, a ferrite core, cable clamp and cable shielding material are required. The cable clamp used by Mitsubishi Electric for the EMC specification compatibility test is shown below.

  • TDK brand ZCAT3035-1330 Ferrite Core Mitsubishi Electric Model AD75CK cable clamp
  • Japan Zipper Tubing Co., Ltd. Zipper tube SHNJ type
  • Cut the ground wire from the core where it protrudes from both ends of the cable.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 88)
Fig. 90 · 8.3.2 Grounding the ground cable
  • Peel the sheath (with the length shown below) at both ends of the cable, and expose the shield braided wire for grounding.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 88)
Fig. 91 · 8.3.2 Grounding the ground cable

Cut the ground wire from the core where it protrudes from both ends of the cable.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 88)
Fig. 92 · 8.3.2 Grounding the ground cable
8. 11 8.3 Wiring Precautions the Part which Matches the EMC Directives 8.3.2 Grounding the ground cable

(1) Bus Connection · (a) For A8GT-C100/200/300EXSS · (b) For A8GT-C100/200/300BS

Page 89 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 8.3.2 Grounding the ground cable
Page 89 · click to enlarge
Page 89
  • Peel the sheath (with the length shown below) at both ends of the cable, and expose the shield braided wire for grounding..
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 89)
Fig. 93 · 8.3.2 Grounding the ground cable
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 89)
Fig. 94 · 8.3.2 Grounding the ground cable

The A8GT-C100/200/300EXSS-1 is a combined product of the A8GT-EXCNB and A8GT-C100/200/300BS.

  • Cut the ground wire from the core where it protrudes from the A8GT-EXCNB..
  • Cut the ground wires protruding from both ends of the A8GT-C100/200/300BS with the length shown below.
  • Peel the sheath (with the length shown below) at both ends, and expose the shield braided wire for grounding..
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 89)
Fig. 95 · 8.3.2 Grounding the ground cable

Ground wire (450mm) Connect to FG of the PLC power supply module

Ground wire (280mm) Connect to FG of the GOT main unit power terminal block

8.3 Wiring Precautions the Part which Matches the EMC Directives 8.3.2 Grounding the ground cable 8 - 12

Page 90 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 8.3.2 Grounding the ground cable
Page 90 · click to enlarge
Page 90

(d) For other Bus Connection cables

  • Wrap the cable shield material around the cable, so that the back aluminum foil side (shield side) of the cable shield material is exposed at both ends of the cable..
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 90)
Fig. 96 · 8.3.2 Grounding the ground cable

*1 The back aluminum foil side of the cable shield material (shield side) should be exposed.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 90)
Fig. 97 · 8.3.2 Grounding the ground cable
8. 13 8.3 Wiring Precautions the Part which Matches the EMC Directives 8.3.2 Grounding the ground cable
Page 91 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 8.3.2 Grounding the ground cable
Page 91 · click to enlarge
Page 91
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 91)
Fig. 98 · 8.3.2 Grounding the ground cable
  • Peel the sheath (with the length shown below) at both ends of the cable, and expose the shield braided wire for grounding..
  • Peel the sheath (with the length shown below) at both ends of the cable, and expose the shield braided wire for grounding..

*1 The back aluminum foil side of the cable shield material (shield side) should be exposed. (Refer to Section 8.3.2 (1)

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 91)
Fig. 99 · 8.3.2 Grounding the ground cable

8.3 Wiring Precautions the Part which Matches the EMC Directives 8.3.2 Grounding the ground cable 8 - 14

Page 92 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 8.3.2 Grounding the ground cable
Page 92 · click to enlarge
Page 92

(3) Computer Link Connection

(a) For RS-232C cable

The user needs to fabricate the RS-232C cable which is used to connect the GOT and Computer link unit side (serial communication, computer link module or PLC CPU with computer link function). The RS-232C cable connection diagram and the connector are as follows. 1) Connection diagram • If D-sub 9-pin is used for the connector of the computer link unit. (A1SJ71QC24(-R2), A1SJ71UC24-R2, A1SJ71C24-R2, A1SCPUC24-R2, A2CCPUC24, QJ71C24(-R2), QJ71CMO)

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 92)
Fig. 100 · 8.3.2 Grounding the ground cable
  • If D-sub 25-pin is used for the connector of the computer link unit. (AJ71QC24(-R2), AJ71UC24)
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 92)
Fig. 101 · 8.3.2 Grounding the ground cable
8. 15 8.3 Wiring Precautions the Part which Matches the EMC Directives 8.3.2 Grounding the ground cable
Page 93 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 8.3.2 Grounding the ground cable
Page 93 · click to enlarge
Page 93
  • 2) Precautions for manufacturing cable
  • Make a twisted pair for each signal and SG.
  • Connect the braided shield to the connector shell (both ends).
  • The cable used for the Mitsubishi EMC Directive compatibility test had the following specifications.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 93)
Fig. 102 · 8.3.2 Grounding the ground cable
  • 3) Connector (connector cover)
  • GOT connector Use the connector matching the following model for the GOT. 9-pin D-sub (male) inch screw type manufactured by DDK 17JE-23090-27 (D3CC)
  • Connector of computer link unit Refer to the user’s manual of the serial communication, computer link module or PLC CPU with computer link function.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 93)
Fig. 103 · 8.3.2 Grounding the ground cable
  • 4) Cable production method
  • Peel the sheath (with the length shown below) at both ends of the cable, and expose the shield braided wire for grounding.
  • The cable must be 15m or shorter.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 93)
Fig. 104 · 8.3.2 Grounding the ground cable

8.3 Wiring Precautions the Part which Matches the EMC Directives 8.3.2 Grounding the ground cable 8 - 16

Page 94 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 8.3.2 Grounding the ground cable
Page 94 · click to enlarge
Page 94

(b) For RS-422 cable (AC30/100/300R4-25P, User created cable)

Refer to the GOT-A900 series User’s Manual (Connection System Manual) for information about the cable creation method. • Wrap the cable shield material around the cable, so that the back aluminum foil side (shield side) of the cable shield material is exposed at both ends of the cable.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 94)
Fig. 105 · 8.3.2 Grounding the ground cable

*1 The back aluminum foil side of the cable shield material (shield side) should be exposed. (Refer to Section 8.3.2 (1)

(4) CC-Link Connection (CC-Link dedicated cable)

  • Peel the sheath (with the length shown below) at both ends of the cable, and expose the shield braided wire for grounding.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 94)
Fig. 106 · 8.3.2 Grounding the ground cable

(5) Ethernet Connection (Twisted pair shield cable) Peel the sheath (with the length shown below) at both ends of the cable, and expose the shield wire for grounding.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 94)
Fig. 107 · 8.3.2 Grounding the ground cable
8. 17 8.3 Wiring Precautions the Part which Matches the EMC Directives 8.3.2 Grounding the ground cable

(b))

Page 95 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 8.3.2 Grounding the ground cable
Page 95 · click to enlarge
Page 95

(6) Other PLC and Microcomputer connection It is necessary for the user to create the cable used to connect GOT with a PLC or a microcomputer from another company (RS-422 cable or RS-232C cable). Refer to the GOT-A900 series User’s Manual (Connection System Manual) for information about the cable creation method.

When connecting GOT to a PLC or microcomputer from another company, configure the system so that the EMC directive specifications from the connection destination are applicable.

The contents shown below are a collection of the contents that should be enforced when made applicable to the EMC directive; however, the final decision to make the device applicable to the EMC directive and how to make it applicable must be made by the manufacturer of the machine device.

(a) For RS-422 cable

  • Each signal wire (excluding SG and FG) should be made into a two power wires and connected, then twisted.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 95)
Fig. 108 · 8.3.2 Grounding the ground cable
  • Make the SG wire more than two wires and connect.
  • Wrap the cable shield material around the cable, so that the back aluminum foil side (shield side) of the cable shield material is exposed at both ends of the cable.

*1 The back aluminum foil side of the cable shield material (shield side) should be exposed. (Refer to Section 8.3.2 (1)

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.2 Grounding the ground cable diagram (page 95)
Fig. 109 · 8.3.2 Grounding the ground cable

8.3 Wiring Precautions the Part which Matches the EMC Directives 8.3.2 Grounding the ground cable 8 - 18

Page 96 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 8.3.3 Grounding the cable
Page 96 · click to enlarge
Page 96

(b) For RS-232C cable

  • Each signal wire (excluding SG, FG) is twisted with SG.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.3 Grounding the cable diagram (page 96)
Fig. 110 · 8.3.3 Grounding the cable
  • Peel the sheath (with the length shown below) at both ends of the cable, and expose the shield braided wire for grounding.
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.3 Grounding the cable diagram (page 96)
Fig. 111 · 8.3.3 Grounding the cable

8.3.3 Grounding the cable

Ground the cable grounding sections and grounding wire to the control panel where the GOT and base unit are grounded.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 8.3.3 Grounding the cable diagram (page 96)
Fig. 112 · 8.3.3 Grounding the cable

For the bus connection cable (in the case of A8GT-C100/200/300EXSS, A8GT-C100/200/300EXSS-1, A8GT-C100/200/300BS), RS-232C cable, CC-Link dedicated cable or shielded twisted-pair cable, ground the braided shield to the control box with the cable clamp (AD75CK).

For the any other bus cable or RS-422 cable, ground the shield surface of the cable shield material to the control box with the cable clamp (AD75CK).

(For details of cable clamp installation, refer to the AD75CK Cable Clamp Instruction Manual .)

8. 19 8.3 Wiring Precautions the Part which Matches the EMC Directives 8.3.3 Grounding the cable
Page 97 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 9.1 Definition of the Error Codes and Messages Displayed
Page 97 · click to enlarge
Page 97
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 9 ERROR CODES AND ERROR MESSAGES diagram (page 97)
Fig. 113

ERROR MESSAGES APPENDICES INDEX

This chapter explains the error codes and error messages displayed by the alarm list (system alarm) display function of the monitoring functions. The error codes may also be confirmed in the error code storage area of the system information function. Refer to the following manual for details of the alarm list (system alarm) function and system information function.

  • When GT Designer is used : Help function of GT Designer
  • When GT Designer2 is used : GT Designer2 Version Reference Manual

9.1 Definition of the Error Codes and Messages Displayed

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 9.1 Definition of the Error Codes and Messages Displayed diagram (page 97)
Fig. 114 · 9.1 Definition of the Error Codes and Messages Displ…

This section describes the definition of the error codes and error messages displayed on the monitor screen by the alarm list (system alarm) display function and the manuals to refer to.

(1) Display format on the monitor screen Displayed in the user-set position

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 9.1 Definition of the Error Codes and Messages Displayed diagram (page 97)
Fig. 115 · 9.1 Definition of the Error Codes and Messages Displ…

Error code Error message Time when error occurred (most recent)

(2) Error codes and manuals to refer to

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 9.1 Definition of the Error Codes and Messages Displayed diagram (page 97)
Fig. 116 · 9.1 Definition of the Error Codes and Messages Displ…

Source of Error Occurrence Error Code Where to Refer To

MNET/B, MNET(II) 200 to 299 [Data Link System Reference Manual of MNET(II), MNET/B] *1

MNET/10 500 to 799 [Network System Reference Manual of MNET/10] *2

CC-Link 800 to 999 [CC-Link System Master Local Module User’s Manual] *3

*1 Take action with reference to the section explaining the link special relay of the (error code) + 9000.

For example, when the error of error code (210) has occurred, 210 + 9000 = 9210 and refer to the explanation of

M9210 and take the corrective action.

*2 Take action with reference to the section explaining the link special relay of the (error code) – 500.

For example, when the error of error code (510) has occurred, 510 - 500 = 10 and refer to the explanation of

SB000A and take the corrective action.

(Since the link special relay is in hexadecimal, replace a decimal by a hexadecimal.)

*3 Take action with reference to the section explaining the link special relay of the (error code) - 800.

For example, when the error of error code (910) has occurred, 910 – 800 = 110 and refer to the explanation of

SB006E and take the corrective action.

(Since the link special relay is in hexadecimal, replace a decimal by a hexadecimal.)

*4 The FXCPU has error codes 100 to 109 and displays the states of M8060 to M8069 with the error codes.

For example, when the error of error code (100) has occurred, refer to the explanation of M8060 and take the cor-

rective action.

9.1 Definition of the Error Codes and Messages Displayed 9 - 1

Page 98 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — GOT
Page 98 · click to enlarge
Page 98

9.2 Error Code and Error Message List

(1) Error messages displayed before execution of monitoring

Error Message Definition Action

1. Check for any disconnected cable or improp-

Check communication line.

The cable, installed communication driver or

erly fitted communication module.

communication module is faulty.

2. Check the installed communication driver.

Unauthorized combination of OS program ver-

Confirm the versions of the OS programs

Check memory data.

sions installed.

installed.

Check the memory board mounting status and

F-ROM abnormal The memory board is not mounted correctly.

mounting screw tightening status.

(2) Error codes and messages displayed during execution of monitoring The error codes and messages detected by the GOT are indicated below.

Error Message Definition Action

303 Too many monitor points

The number of objects set to the screen to be dis-

played is too many to reserve the work area of the

Reduce the number of objects 304 Too many trigger points specified

The number of objects set to the screen for print-

305 Too many print-out points speci-

out by the hard copy function is too many to

reserve the work area of the system

Screen data has not been downloaded to the built-

306 No monitor data

Download the screen data to the built-in memory

307 No monitor device setting Object monitoring devices not determined Determine object monitoring devices

308 Specified comment not found or

The comment number set for comment display

Create the comment file and download it to the

does not exist or the comment file does not exist

GOT

309 Device read error Device data read caused an error Correct device

(1) The specified base screen/window screen

(1) Specify the existing base screen/window

310 Specified monitor data not found

does not exist in the project data. (2) The specified base screen/window screen

screen. (2) Specify the existing base screen/window

is outside the permissible range.

screen.

The alarms in the history has exceeded the largest

311 More than 1024 alarms in alarm

Reduce the alarms in the alarm history

number of points (1024 points) which the alarm

(Remove the history recovered)

history display function can monitor

The collected time exceeded the upper limit when

1. Establish "Clear trigger" set for the scattered

the following setting had been made for the scat-

312 The collected time has

chart.

tered chart.

2. Set "Operation at frequency over time" of the

scattered chart for "Initialize and continue".

315 Device write error Data write to device caused an error Correct device

Reconsider the data operation formula so that the

316 Operation result value cannot be

The data operation result has exceeded the range

operation result does exceeded the range which

which can be represented by the device type

can be represented by the device type

320 Specified part not found or out-

The part number set for part display does not

Confirm the part number specified for the part dis-

exist.

play in the screen data

9. 2 9.2 Error Code and Error Message List
Show 14 more labels / short text on this page
(Cable, driver, module) · Error · Code · specified · fied · in memory · outside range · or outside range · history · exceeded upper limit · "Store memory" · "Accumulate/Average" · displayed/entered · side range
Page 99 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — ERROR CODES AND
Page 99 · click to enlarge
Page 99

Error Message Definition Action

ERROR CODES AND

ERROR MESSAGES APPENDICES INDEX

The station number specified as a monitor destina-

321 Unauthorized station number

Confirm the monitor destination station number in

tion does not exist or is not the station to be moni-

specified for monitor device

322 Specified device outside range

The device number to be monitored is outside the

Set the monitored PLC CPU and parameters to set

the device in the monitorable range 323 Specified file register outside

permissible range of the corresponding PLC CPU

324 AD51H-dedicated device used

The AD51H-dedicated device was monitored in the

Incorporate the AD51H into the system or stop

system which does not use the AD51H

monitoring of the AD51H-dedicated device

325 Specified special module not

Check the loading status of the specified special

The specified special module is not loaded

330 PC card capacity short The PC card does not have enough capacity Check the capacity

331 PC card not loaded or memory

The PC card is not loaded or the memory card

1. Load the PC card

card access switch OFF

access switch is OFF

2. Turn ON the access switch

332 Format error The PC card is not formatted Format the PC card

333 PC card write-protected to dis-

The PC card is write-protected Make the PC card write-enabled

334 PC card fault PC card failure Change the PC card

335 PC card battery voltage low The battery voltage of the PC card is low Change the battery of the PC card

340 Printer in error or power off

1. Check the printer

The printer is faulty or its power is not on

2. The Printer switch it on 341 Printer fault
1. If external power (24VDC) is not supplied, sup-

342 The fuse of KBF module was

A fault occurred in the external I/O interface mod-

ply external power.

ule.

2. If external power is supplied, change the exter-

nal I/O interface module.

The external I/O interface module is not mounted

343 KBF module status is abnormal

Mount the external I/O interface module properly.

properly.

1. Change the device data to be displayed into a

It has been attempted to display/enter a value that

345 BCD/BIN conversion error

cannot be BCD/BIN converted

2. Enter the value of 4-digit integer
1. Check for an unplugged communication cable

The cable used to connect the GOT and personal

350 RS-232C communication error

2. check the cables used
1. Check recipe file data in PC card

351 Recipe file abnormal Recipe file data are not normal

2. Start GOT after deleting recipe file in PC card

352 Recipe file generation error Recipe file generation failed Start GOT after loading PC card

1. Check write protect of PC card

353 Recipe file write disabled Data write to recipe file failed

2. Check PC card capacity
3. Do not unload PC card during recipe operation

354 Error during recipe file write Error occurred during recipe file write Do not unload PC card during recipe operation

1. Do not unload PC card during recipe operation

355 Error during recipe file read Error occurred during recipe file read

2. Check recipe file data (device values) in PC card

9.2 Error Code and Error Message List 9 - 3

Show 13 more labels / short text on this page
Error · Code · the screen data · tored · range · without AD51H · loaded · module · able write · blown · BCD value · connector · computer is faulty
Page 100 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 9.2 Error Code and Error Message List
Page 100 · click to enlarge
Page 100

Error Message Definition Action

1. Check the file register name, and then operate

When the file register name is designated and then

the recipe function again.

356 File system error occurred in

the recipe function is operated, an error occurs in

2. Apply Format PLC memory to the designated

the designated file register.

PLC drive with the GX Developer, and then

operate the recipe function again.

1. Check the designated PLC drive, and then oper-

When the file register name is designated and then

ate the recipe function again.

357 The specified drive of PLC is

the recipe function is operated, there is a fault in

2. Apply Format PLC memory to the designated

the PLC drive.

PLC drive with the GX Developer, and then

operate the recipe function again.

1. Check the designated PLC drive/ file register

name, and then operate the recipe function

again (If drive 0 was designated, change to a

When the file register name is designated and then

different drive, and then operate the recipe func-

358 File of PLC access failure

the recipe function is operated, the PLC file regis-

tion again).

ter could not be accessed.

2. Check whether the memory card is write-pro-

tected, and then operate the recipe function

again.

When the file register name is designated and then

359 Processing is from another

Wait until the peripheral devices finish operating,

the recipe function is operated, other peripheral

and then operate the recipe function again.

devices begin processing for the file register.

Reconsider the data operation formula to avoid the

360 Division error due to divisor of 0 Divisor 0 occurred in the data operation formula

Contradiction in magnitude rela-

Upper and lower limit values have been set as

Check the upper and lower limit value setting and

tionship of upper and lower limit

[upper limit lower limit]

correct them to be [upper limit lower limit]

1. Check for any disconnected cable or improperly
2. This may occur if the programmable logic con-

troller load is increased while accessing another

402 Communication time-out Time-out error occurred during communication

station. In this case, move the other station's

data to the local station's programmable logic

controller, and monitor with the local station.

3. If the sequence scan is long, insert a COM com-

mand.

Check the cable connection status, the communi-

At the time of receive during RS-422/RS-232C

cation board/communication module mounting sta-

403 SIO request status error

communication, any of overrun error, parity bit

tus, the PLC status, and the communication link

error and framing error occurred.

transmission speed.

(1) The station number specified for CC-Link con-

nection (via G4) is other than that of the master/

406 Specified station doesn’t access

Check the station number of the monitor screen

local station.

for out of range

data.

(2) Access was made to the CPU other than the

QCPU.

407 Other network accessed by

Access was made to the other network at the time

Check the network number in the screen data to

of MELSECNET connection (network system)

avoid access to the other network

421 The specification of E71 cannot

The Ethernet module on the PLC side has been

Set the PLC side Ethernet module for write enable.

set for write disable.

The CPU is faulty or communication cannot be

422 It is not communicate between

Check the CPU for any fault using GX Developer

made between the CPU and PLC side Ethernet

the CPU and E71

or like. (Check the buffer memory.)

module.

9. 4 9.2 Error Code and Error Message List
Show 11 more labels / short text on this page
Error · Code · the PLC · abnormal · peripheral device · divisor of 0 · values · fitted communication board/communication · module · MNET10 module · be written
Page 101 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — ERROR CODES AND
Page 101 · click to enlarge
Page 101

Error Message Definition Action

ERROR CODES AND

ERROR MESSAGES APPENDICES INDEX

Add the station number set as the screen data to

the Ethernet setting of GT Designer/GT Designer

The station number set as the screen data does

423 Information is insufficient in net-

not exist in the Ethernet setting of GT Designer/ GT

(Use the station number of the PLC side Ethernet

Designer 2.

module set in the parameter setting of GX Devel-

oper.)

Check the following data and do not use the same

station number.

1. Check the station number of the GOT on the util-

The station number set on the utility screen of the

ity screen of the GOT.

GOT is the same as the station number set in the

2. Check the station number set as the screen

424 The same bureau is set by GOT

Ethernet setting of GT Designer/GT Designer 2

data.

and monitor data.

(station number of the PLC side Ethernet module)

3. Check the station number set in the Ethernet

or the station number set as the screen data.

setting.

(Use the station number of the PLC side Ether-

net module set in the parameter setting of GX

Developer.)

448 Devices outside file register and

Devices specified are outside file register or buffer

Set PLC file registers. Also correct monitor devices

memory range of QnACPU

Check whether the corresponding communication

During monitoring of the other station via

station has been set correctly in the management

MELSECNET/10, a fault occurred in the corre-

station (reconsider the parameters, switch setting,

etc.)

Check for any disconnected cable or improperly fit-

499 CPU communication error Other communication error

9.2 Error Code and Error Message List 9 - 5

Show 8 more labels / short text on this page
Error · Code · work table · other ranges included · 470 Communication destination · faulty · sponding communication station · ted communication module
Page 102 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 9.3 Precautions for Installation of ROM_BIOS
Page 102 · click to enlarge
Page 102

9.3 Precautions for Installation of ROM_BIOS

(1) About ROM_BIOS ROM_BIOS is available in two types: for large-sized GOTs (A985GOT(-V), A975GOT, A970GOT, A960GOT) and for medium-sized GOTs (A950GOT, A951GOT, A953GOT, A956GOT) and wide- sized GOT (A956WGOT).

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 9.3 Precautions for Installation of ROM_BIOS diagram (page 102)
Fig. 117 · 9.3 Precautions for Installation of ROM_BIOS
  • Do not install ROM_BIOS designed for large-sized GOT in any of the DoA950GOT, A951GOT, A953GOT, A956GOT and A956WGOT.
  • Do not install ROM_BIOS designated for large-sized GOTs or medium-sized GOTs in the A956WGOT.
  • Do not install ROM_BIOS of a version earlier than the version of ROM_BIOS installed in the GOT.

Refer to the following manual for the ROM_BIOS installation method.

  • When GT Designer is used:GT Works Version /GT Designer Version Reference Manual
  • When GT Designer2 is used: GT Works2 Version /GT Designer2 Version Operating Manual
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 9.3 Precautions for Installation of ROM_BIOS diagram (page 102)
Fig. 118 · 9.3 Precautions for Installation of ROM_BIOS

Check the rating plate on the back of the GOT to confirm the version of ROM_BIOS factory-installed in the GOT.

9. 6 9.3 Precautions for Installation of ROM_BIOS
Page 103 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — ERROR CODES AND
Page 103 · click to enlarge
Page 103

(2) About the messages displayed

ERROR CODES AND

ERROR MESSAGES APPENDICES INDEX

(a) The GOT will display the following messages if you attempt to install ROM_BIOS that is not

compatible with the GOT to be used. Should the following messages appear due to wrong operation you performed, there will be no problems since installation is not executed and ROM_BIOS is not rewritten.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — ERROR CODES AND diagram (page 103)
Fig. 119

A few seconds later

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — ERROR CODES AND diagram (page 103)
Fig. 120

If the above messages have appeared, hold the above screen in that status and install the standard monitor OS, communication driver and so on.

The following message will also appear when you power on your GOT for the first time.

In this case, the message does not relate to the installation of ROM_BIOS.

Unless you install the standard monitor OS, the following message will appear whenever you start the GOT.

9.3 Precautions for Installation of ROM_BIOS 9 - 7

Page 104 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — ROM_BIOS setup Ver1. 1. 0 [B]
Page 104 · click to enlarge
Page 104

(b) The GOT will display the following messages if you attempt to install ROM_BIOS of a version

earlier than the version of ROM_BIOS installed in the GOT. Should the following messages appear due to wrong operation you performed, there will be no problems since installation is not executed and ROM_BIOS is not rewritten.

ROM_BIOS setup Ver1. 1. 0 [B]

Don't turn off the power supply Don't push the reset button. ROM_BIOS Not Rewritable. GOT stopped Please install operating system.

If the above messages have appeared, hold the above screen in that status and install the standard monitor OS, communication driver and so on.

9. 8 9.3 Precautions for Installation of ROM_BIOS
Page 105 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 9.4.1 Locating error positions
Page 105 · click to enlarge
Page 105

9.4 Troubleshooting in bus connection

ERROR CODES AND

ERROR MESSAGES APPENDICES INDEX

If a cause cannot be located by the troubleshooting procedures specified in section 9.2 when the GOT is bus-connected to the PLC CPU, troubleshoot the cause as follows.

9.4.1 Locating error positions

(1) How to locate error positions:

(a) Use of peripheral devices

Using the peripheral devices such as GPP, check what type of the error occurs on the PLC CPU and, based on the error message on the PLC CPU and the check points (See item (2) below), check each module and cable for installation and earthing statuses.

Check the timing of errors. 1) An error occurs when the power is turned on or immediately after the PLC is reset: The error may be detected by the initial processing of the PLC CPU. In this case, because the faulty module may not be identified, use only an END instruction for the sequence program and remove the modules one by one until the error does not occur. When the error is eliminated after a specific module has been removed, the module may be causing the error.

2. An error occurs after a specific operation or several seconds: The error may occur in the sequence program. Check the error step where the error may occur and the sequence program in that step. The sequence program can be diagnosed throughout by merely using an END instruction for the sequence program.
3. An error occurs when a specific device operates: The mis-operation may be caused by noise. Check that any signal line such as bus cable is not laid out too close to the operating device. If the line is too close to the device, separate the line 100 mm or more from the device.

(c) Locating the module where an error occurs: Based on the PLC CPU error codes and special resister information (See item (2)), locate a specific module where an error occurs.

By the method stated above, correct the sequence program or replace the faulty module with a new one, and check whether the error occurs. If the error continues to occur, it may have another cause. Referring to section 9.4.2, locate the error position further.

9.4 Troubleshooting in bus connection 9.4.1 Locating error positions 9 - 9

(b) Error timing

Page 106 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 46 SP. UNIT
Page 106 · click to enlarge
Page 106

(2) Error messages appearing due to faulty ACPU bus connection and measure against errors

Cause and check point

(1) The scanning time exceeds

the calculation congestion monitoring time. (2) The scanning time may be

(1) Use the error history to check whether

simultaneous occurrence errors are present. (2) Refer to the SP module down check

extended by waiting for a response from an SP module that is down, and errors may occur simultaneously.

22 WDT ERR.

points.

The information stored in the cards

of the module installed in the base

Check the faulty module at special resisters

module and the communication

D9116 to D9123.

module of the GOT is different

31 UNIT VER-

(1) Check that the module and the cables

from that read at the initial time.

IFY ERR.

are connected correctly. (2) Check that the PLC and the GOT are

(If an error occurs on a module

(vacant) other than that installed in

earthed correctly.

the base module, the mis-opera-

tion may be caused by noise.)

Check the faulty module from the error step.

(1) Check that the module and the cables

When the FROM/TO instruction is

are connected correctly. (2) Replace the faulty module with a new

executed, an imprecise response

is returned from the special func-

one. (3) Check that the PLC and the GOT are

tion module (including the GOT).

earthed correctly.

(1) Check that the module and the cables

CONTROL

are connected correctly. (2) Because a faulty module cannot be

_BUS

ACPU

ERR.

At the time of initial communica-

located, remove the modules one by one until no CONTROL_BUS ERR. message appears to indicate the module where the error occurs. (Because the modules are removed, SP. UNIT ERR. message may appear. Stop transmitting the FROM/TO instruction to the applicable module.)

At CPU power ON/

tion, an imprecise response is

returned from the special function

module (including the GOT).

Check the faulty module from the error step.

The special function module was

(1) Check that the module and the cables

are connected correctly. (2) Replace the faulty module with a new

accessed during the execution of a

FROM/TO instruction set, but

one. (3) Check that the PLC and the GOT are

41 SP. UNIT

there was no response.

DOWN

earthed correctly.

At the time of initial communica-

(1) Check that the module and the cables

At CPU power ON/

tion, a response is not returned

are connected correctly. (2) Replace the faulty module with a new

from the special function module

(including the GOT).

one. (3) Check that the PLC and the GOT are

earthed correctly. 43 I/O INT

An imprecise interrupt occurs to

ERR.

the PLC CPU.

(1) Check the number of installed modules. (2) Check the number of extension stages

44 SP. UNIT

At CPU power ON/

Too many modules are installed

LAY ERR.

(see the PLC CPU specification).

and the I/O slot numbers.

The FROM/TO instruction is exe-

(1) Review the sequence program. (2) Check the number of extension stages

46 SP. UNIT

cuted to any module other than the

ERR.

and the I/O slot numbers.

special function module.

9. 10 9.4 Troubleshooting in bus connection 9.4.1 Locating error positions
Show 27 more labels / short text on this page
Error · Error · Check Timing · Correspond- · Code · Messages · Error detail Remedy · ing CPU · When an End · instruction is exe- · cuted · When an End · instruction is exe- · cuted · During execution of · FROM/TO instruc- · tion set · At reset · During execution of · FROM/TO instruc- · tion set · At reset · During interrupt · At reset · During execution of · FROM/TO instruc- · tion set
Page 107 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — QCPU
Page 107 · click to enlarge
Page 107

(3) Error messages appearing due to faulty Q/QnACPU bus connection and measure against errors

ERROR CODES AND

ERROR MESSAGES APPENDICES INDEX

Cause and check point

1310 I/O INT

An imprecise interrupt occurs to the PLC

QCPU

ERROR.

CPU.

There was no response from the intelli-

At CPU power ON/

gent function module during initial com-

munications stage.

QCPU

  • The size of the buffer memory of the

ule is accessed.

intelligent function module is abnormal.

At the time of initial communication, a

At CPU power ON/

(1) Check that the module and the

response is not returned from the special

cables are connected correctly. (2) Replace the faulty module and

function module (including the GOT).

The intelligent function module was

the cables with new ones. (3) Check that the PLC and the GOT

SP. UNIT

accessed in the program, but there was

QCPU

are earthed correctly. (4) Check the number of extension

DOWN

no response.

is executed.

The special function module was

stages and the I/O slot numbers.

accessed during the execution of a

FROM/TO instruction set, but there was

no response.

There was no response from the intelli-

gent function module when the END

instruction is executed.

QCPU

  • An error is detected at the intelligent

function module.

(1) Check that the module and the

cables are connected correctly. (2) Because a faulty module cannot

be located, remove the modules one by one until no CONTROL_BUS ERR. message appears to indicate the module where the error occurs. (Because the modules are removed, SP. UNIT ERR. message may appear. Stop transmitting the FROM/TO instruction to the applicable module.)

At the time of initial communication, an

CONTROL

imprecise response is returned from the

_BUS

At CPU power ON

special function module (including the

ERR.

GOT).

QCPU

Check the faulty module from the

error step. (1) Check that the module and the

When the FROM/TO instruction is exe-

cuted, an imprecise response is returned

cables are connected correctly. (2) Replace the faulty module with a

from the special function module (includ-

new one. (3) Check that the PLC and the GOT

ing the GOT).

are earthed correctly.

The information stored in the cards of the

module installed in the base module and

Check the faulty module at special

the communication module of the GOT is

resisters SD1400 to SD1431.

2000 UNIT VER-

different from that read at the initial time.

(1) Check that the module and the

QCPU

IFY ERR.

(If an error occurs on a module (vacant)

cables are connected correctly. (2) Check that the PLC and the GOT

other than that installed in the base mod-

ule, the mis-operation may be caused by

are earthed correctly.

noise.)

9.4 Troubleshooting in bus connection 9.4.1 Locating error positions 9 - 11

Show 32 more labels / short text on this page
Error · Error · Check Timing · Correspond- · Code · Messages · Error detail Remedy · ing CPU · During interrupt · QnACPU · At reset/When intel- · ligent function mod- · QnACPU · At reset · When an intelligent · function module · access instruction · During execution of · FROM/TO instruc- · QnACPU · tion set · When an End · instruction is exe- · cuted · QnACPU · During execution of · FROM/TO instruc- · tion set · When an End · instruction is exe- · QnACPU · cuted
Page 108 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — A1SJ71BR11, A1SJ71AP21 ,
Page 108 · click to enlarge
Page 108

Cause and check point

(1) In the parameter I/O allocation set- tings, an intelligent function module was allocated to a location reserved for an I/O module. Or, the opposite has happened. (2) In the parameter I/O allocation set- tings, a module other than CPU (or noth- ing) was allocated to a location reserved for a CPU module. Or, the opposite has happened. (3) A general-purpose switch was set to the module with no general-purpose switches.

(1) Reset the parameter I/O

allocation according to the status of installation of the intelligent function module. (2) Reset the parameter I/O

allocation according to the status of installation of the CPU module. (3) Reset the general-purpose switch

QCPU

settings. (4) Check the number of extension

stages and the I/O slot numbers.

(1) Reset the parameter I/O

In parameter I/O allocation settings, a special function module was allocated to a location reserved for an I/O module. Or, the opposite has happened.

allocation setting to conform with the actual status of the special function modules. (2) Check the number of extension

stages and the I/O slot numbers.

(1) Check the number of installed

The modules more than those specified in the PLC CPU specification are installed.

modules. (2) Check the number of extension

stages and the I/O slot numbers.

At the MELSECNET/MINI auto refresh parameter settings, the module allocation that was set is different from the actual module models at the station numbers in the link system.

Reset the parameter MELSECNET/ MINI auto refresh unit module allocation setting so that it conforms to the station number of the module that is actually linked.

2105 There are too many special function mod- ules that can use dedicated instructions allocated (number of modules installed).

Reduce the number of special function modules installed.

SP. UNIT LAY ERR.

At CPU power ON/ At reset

(1) 5 or more QJ71LP21/BR11 have been installed. (2) 5 or more QJ71E71 (-B2) have been installed. (3) Identical network numbers or station numbers exist in the MELSECNET/10 network system.

(1) Keep the number to 4 or fewer. (2) Keep the number to 4 or fewer. (3) Check the network numbers and

QCPU

station numbers.

(1) Reset the parameter I/O

allocation setting to conform with the actual status of the special function modules. (2) Check the number of extension

2107 Head X/Y set at the parameter I/O alloca- tion settings is also the head X/Y for some other module.

stages and the I/O slot numbers.

(1) Network module A1SJ71LP21,

A1SJ71BR11, A1SJ71AP21 ,

A1SJ71AR21, or A1SJ71AT2 B dedi- cated for the A2USCPU has been installed. (2) Network module A1SJ71QLP21 or A1SJ71QBR11 dedicated for the Q2AS has been installed. Change the network module to QJ71LP21 or QJ71BR11.

Change network module to QJ71LP21 or QJ71BR11. QCPU

AJ71LP21 or AJ71BR11 for use with the AnUCPU network module has been installed.

Change network module to AJ71QLP21 or AJ71QBR11. QnACPU

The control system and standby system module configurations are different when a redundant system is in the backup mode.

Check the module configuration of the standby system. Q4ARCPU

9. 12 9.4 Troubleshooting in bus connection 9.4.1 Locating error positions
Show 13 more labels / short text on this page
Error · Error · Check Timing · Correspond- · Code · Messages · Error detail Remedy · ing CPU · QnACPU · 2101 to 2103 · QCPU QnACPU · QnACPU · QCPU QnACPU
Page 109 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — QCPU
Page 109 · click to enlarge
Page 109

Cause and check point

ERROR CODES AND

ERROR MESSAGES APPENDICES INDEX

The FROM/TO instruction is executed to

any module other than the special func-

(1) Review the sequence program. (2) Replace the faulty module with a

tion module.

2111 The location designated by link direct

new one.

device (J / ) is not a network module.

(1) The location designated by a

special function module dedicated instruction is not a special function module. (2) Alternatively, it is not the relevant

SP. UNIT

QCPU

Review the sequence program.

ERROR.

special function module.

STOP RUN

Read error individual information, then

No special function module data for simu-

check and edit the special function mod-

lation purposes has been set in the simu-

ule simulation data that corresponds to

lation data.

the numerical value there (program

error location).

The location of Q B and QA1S B is

Check the location of the base unit.

improper.

2122 QA1S B is installed to the basic base

Install Q B as the basic base unit.

unit.

(1) Remove the module installed at

65th or later slot. (2) Remove the module installed at

(1) A module is installed at 65th or later

slot. (2) A module is installed at the slot later

the slot later than the number of slots specified with base allocation setting. (3) Remove the module installed at

SP. UNIT

At CPU power ON/

than the number of slots specified with base allocation setting. (3) A module is installed at the I/O

QCPU

LAY ERR.

the I/O points later than the 4,096th point. (4) Change the last module to a

points later than the 4,096th point. (4) A module installed at the 4,096th

point occupies later points.

module which does not exceed the 4,096th point.

(1) A module which the QCPU cannot

(1) Install a module which can be

recognize has been installed. (2) There was no response form the

used with the QCPU. (2) Replace the faulty module with a

intelligent function module.

new one.

Program scan time for initial execution

type program goes over the initial execu-

Read the error individual information at

tion WDT time set in the parameter PC

WDT

a peripheral device, check the numerical

QCPU

RAS settings.

ERROR.

value (time) there, and shorten scan

Program scan time goes over the WDT

time if necessary.

value set in the parameter PC RAS set-

tings.

9.4 Troubleshooting in bus connection 9.4.1 Locating error positions 9 - 13

Show 16 more labels / short text on this page
Error · Error · Check Timing · Correspond- · Code · Messages · Error detail Remedy · ing CPU · When instruction · executed · QnACPU · When instruction · executed/ · At reset · Always · QnACPU
Page 110 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 9.4.2 Further locating error positions
Page 110 · click to enlarge
Page 110

9.4.2 Further locating error positions

If the function of the PLC cannot be recovered even when the module on which an error occurs is replaced with a new one, the error may be caused by the effect from another module. Disconnect the extension cables and bus connection cables in order from the modules starting from the module located furthest from the operating position in the system, and check for the status of occurrence of the error each time the cables are disconnected until the error does not occur. The module or extension cables/bus-connection cables disconnected immediately before the error does not occur are considered to cause the error. Examples of the ways of further locating error positions are shown below.

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — 9.4.2 Further locating error positions diagram (page 110)
Fig. 121 · 9.4.2 Further locating error positions

Disconnect the bus-connection cable (IN side) from the final stage GOT.

Disconnect the bus-connection cable (OUT side) from the GOT located one stage before the final stage.

If an error does not occur, the final stage GOT may be faulty.

If an error does not occur, the final stage GOT and the bus-connection cable before the final stage may be faulty.

Repeat the examples 1 and 2 above to locate error positions.

  • When disconnecting the extension base units in order, use only an END instruction for the sequence program, and any error resulting from the sequence program will not occur, and the status of occurrence of errors will be obtained easily.
  • When the frequency of occurrence of an error is low, check the error by taking a rather long time with the modules disconnected.
  • The checks stated above are effective to locate a noise invading route when the mis-operation is caused by noise.
9. 14 9.4 Troubleshooting in bus connection 9.4.2 Further locating error positions
Page 111 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — GOT 1) GOT 2)
Page 111 · click to enlarge
Page 111

9.4.3 Specific example of troubleshooting

ERROR CODES AND

ERROR MESSAGES APPENDICES INDEX

An example of troubleshooting the system which is used when an error occurs on the PLC CPU is shown below.

PLC (main base module)

GOT 1) GOT 2)

PLC (extension base module)

Check the error code/step appearing on the PLC CPU. (Obtain the status of the error and the location where the error occurs.)

The SP. UNIT DOWN message appears on CPU.

Turn off the power of the GOT. Turn off the power of the PLC CPU.

Replace the faulty CPU with a new one.

Turn on the power of the PLC CPU.

Turn on the power of the GOT.

The error occurs further (not on CPU).

Turn off the power of the GOT. Turn off the power of the PLC CPU.

Disconnect the bus-connection cable from the GOT 2) at IN side

(to further locate the error positions).

Turn on the power of the PLC CPU.

Turn on the power of the GOT.

The error occurs further (not on the GOT 2) (bus interface module).

Turn off the power of the GOT. Turn off the power of the PLC CPU.

Disconnect the bus-connection cable from the GOT 1) at OUT side

(to further locate the error positions).

Turn on the power of the PLC CPU.

Turn on the power of the GOT.

The error will not occur.

The bus-connection cable connecting the GOT 1) to the GOT 2) is judged faulty.

Replace the faulty bus-connection cable with a new one.

9.4 Troubleshooting in bus connection 9.4.3 Specific example of troubleshooting 9 - 15

Show 5 more labels / short text on this page
Extension cable · Bus-connection cable · Bus-connection cable · Start · End
Page 112 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — NO
Page 112 · click to enlarge
Page 112

9.5 Troubleshooting for monitoring

The following describes the corrective action when the GOT monitoring screen is blank.

The GOT screen is blank

YES

The GOT Power LED is off.

Power on the GOT.

NO

If the screen will come back, this means the screensaver is set.

YES

The screen will come back on by touching the display section.

This function can be set within the GOT utility menu. 1

NO

The bit of "Forces Screen Saver Enable Signal" for GOT may be on.

YES

System information function (system signal 1) is set. Check the bit status.

If bit is on, turn it off. 2

NO

The backlight has reached its maximum life span.

YES

(Compare the backlight life span and

Replace the backlight.

the operating time.)

NO

Possible cause is GOT hardware fault.

Consult your sales representative.

*1 Refer to GOT-A900 Series Operating Manual (Extended _ Option Functions Manual), for utility menu.

*2 Refer to the following manual for details of the forced screen save signal.

When GT Designer is used:Help function of GT Designer

When GT Designer2 is used:GT Designer2 Version Reference Manual

9. 16 9.5 Troubleshooting for monitoring
Page 113 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — ERROR MESSAGES APPENDICES INDEX
Page 113 · click to enlarge
Page 113

APPENDICES

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — APPENDICES diagram (page 113)
Fig. 122

ERROR MESSAGES APPENDICES INDEX

1. Outline dimension drawing of the A95*GOT
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — ERROR MESSAGES APPENDICES INDEX diagram (page 113)
Fig. 123
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — ERROR MESSAGES APPENDICES INDEX diagram (page 113)
Fig. 124

Type code A B C D E F G H I J K L M

Appendix.1 Outline Dimension Drawings APP - 1

Unit (mm (inch)

Page 114 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — APPENDICES
Page 114 · click to enlarge
Page 114
2. Outline dimension drawing of the A956WGOT
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — APPENDICES diagram (page 114)
Fig. 125

APP - 2 Appendix.1 Outline Dimension Drawings

Page 115 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — ERROR MESSAGES APPENDICES INDEX
Page 115 · click to enlarge
Page 115

Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only)

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only) diagram (page 115)
Fig. 126 · Appendix.2 Depth at the Time of Communication Module…

ERROR MESSAGES APPENDICES INDEX

(1) When A9GT-50WQBUSS is used

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — ERROR MESSAGES APPENDICES INDEX diagram (page 115)
Fig. 127

(2) When A9GT-50WBUSS is used

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — ERROR MESSAGES APPENDICES INDEX diagram (page 115)
Fig. 128

(3) When A9GT-50WRS2/A9GT-50WRS4 is used

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — ERROR MESSAGES APPENDICES INDEX diagram (page 115)
Fig. 129

Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only) APP - 3

Page 116 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only)
Page 116 · click to enlarge
Page 116

(4) When A9GT-QBUS2SU/A9GT-BUSSU/A9GT-BUS2SU is used

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only) diagram (page 116)
Fig. 130 · Appendix.2 Depth at the Time of Communication Module…

(5) When A7GT-BUSS/A7GT-BUS2S is used

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only) diagram (page 116)
Fig. 131 · Appendix.2 Depth at the Time of Communication Module…

(6) When A9GT-QJ71LP23/A7GT-J71AP23/A7GT-J71LP23 is used

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only) diagram (page 116)
Fig. 132 · Appendix.2 Depth at the Time of Communication Module…

*1 Determined by the optical fiber cable and connector used.

APP - 4 Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only)

Page 117 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only)
Page 117 · click to enlarge
Page 117
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only) diagram (page 117)
Fig. 133 · Appendix.2 Depth at the Time of Communication Module…

*2 Determined by the coaxial cable and connector used.

Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only) APP - 5

Page 118 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only)
Page 118 · click to enlarge
Page 118

(10) When A9GT-J71E71-T is used

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only) diagram (page 118)
Fig. 134 · Appendix.2 Depth at the Time of Communication Module…

*3 The bending radius (R1: guideline value) near the connector should be the cable outline 4 or more.

(11) When A9GT-50PRF is used

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only) diagram (page 118)
Fig. 135 · Appendix.2 Depth at the Time of Communication Module…

(12) When A8GT-50KBF is used

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only) diagram (page 118)
Fig. 136 · Appendix.2 Depth at the Time of Communication Module…

APP - 6 Appendix.2 Depth at the Time of Communication Module Loading (A956GOT/A956WGOT Only)

Page 119 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — Appendix.3 Outline Dimension Drawings of Bus Connection Cables
Page 119 · click to enlarge
Page 119
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — Appendix.3 Outline Dimension Drawings of Bus Connection Cables diagram (page 119)
Fig. 137 · Appendix.3 Outline Dimension Drawings of Bus Connect…

*1 The A8GT-C EXSS/C BS cable has a ground cable (1m).

Always connect this ground cable to the control panel or other places.

*2 The A8GT-C EXSS-1 is provided as a set of the A8GT-EXCNB and A8GT-C BS. (Refer to Fig. 8.)

Fig. 1 Fig. 2

33.0 (1.3)

(0.45)

58.0 (2.28)

(0.49)

49.7 (1.96)

49.9 (1.96)

Fig. 3 Fig. 4

60.0 (2.36)

60.0 (2.36) 20.0 (0.79)

20.0 (0.79)

58.0 (2.28)

58.0 (2.28)

Fig. 5 Fig. 6

35.0 (1.38) 33.0 (1.30)

10.0 (0.39)

12.4 (0.49)

42.0 (1.65)

49.9 (1.96)

Fig. 7 Fig. 8

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — Appendix.3 Outline Dimension Drawings of Bus Connection Cables diagram (page 119)
Fig. 138 · Appendix.3 Outline Dimension Drawings of Bus Connect…

75.0 (2.95)

(0.81)

60.0 (2.36)

Unitmm

Appendix.3 Outline Dimension Drawings of Bus Connection Cables APP - 7

Page 122 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — 1. Gratis Warranty Term and Gratis Warranty Range
Page 122 · click to enlarge
Page 122

Warranty

Please confirm the following product warranty details before using this product.

1. Gratis Warranty Term and Gratis Warranty Range

If any faults or defects (hereinafter "Failure") found to be the responsibility of Mitsubishi occurs during use of the product within the gratis warranty term, the product shall be repaired at no cost via the sales representative or Mitsubishi Service Company. However, if repairs are required onsite at domestic or overseas location, expenses to send an engineer will be solely at the customer’s discretion. Mitsubishi shall not be held responsible for any re-commissioning, maintenance, or testing on-site that involves replacement of the failed module. [Gratis Warranty Term]

The gratis warranty term of the product shall be for one year after the date of purchase or delivery to a designated place. Note that after manufacture and shipment from Mitsubishi, the maximum distribution period shall be six (6) months, and the longest gratis warranty term after manufacturing shall be eighteen (18) months. The gratis warranty term of repair parts shall not exceed the gratis warranty term before repairs. [Gratis Warranty Range]

(1) The range shall be limited to normal use within the usage state, usage methods and usage environment, etc.,

which follow the conditions and precautions, etc., given in the instruction manual, user's manual and caution labels on the product. (2) Even within the gratis warranty term, repairs shall be charged for in the following cases.

1. Failure occurring from inappropriate storage or handling, carelessness or negligence by the user. Failure caused by the user's hardware or software design. 2. Failure caused by unapproved modifications, etc., to the product by the user. 3. When the Mitsubishi product is assembled into a user's device, Failure that could have been avoided if functions or structures, judged as necessary in the legal safety measures the user's device is subject to or as necessary by industry standards, had been provided. 4. Failure that could have been avoided if consumable parts (battery, backlight, fuse, etc.) designated in the instruction manual had been correctly serviced or replaced. 5. Failure caused by external irresistible forces such as fires or abnormal voltages, and Failure caused by force majeure such as earthquakes, lightning, wind and water damage. 6. Failure caused by reasons unpredictable by scientific technology standards at time of shipment from Mitsubishi. 7. Any other failure found not to be the responsibility of Mitsubishi or that admitted not to be so by the user. 2. Onerous repair term after discontinuation of production (1) Mitsubishi shall accept onerous product repairs for seven (7) years after production of the product is

discontinued. Discontinuation of production shall be notified with Mitsubishi Technical Bulletins, etc. (2) Product supply (including repair parts) is not available after production is discontinued. 3. Overseas service Overseas, repairs shall be accepted by Mitsubishi's local overseas FA Center. Note that the repair conditions at each FA Center may differ. 4. Exclusion of loss in opportunity and secondary loss from warranty liability Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation of damages caused by any cause found not to be the responsibility of Mitsubishi, loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products, special damages and secondary damages whether foreseeable or not, compensation for accidents, and compensation for damages to products other than Mitsubishi products, replacement by the user, maintenance of on-site equipment, start-up test run and other tasks. 5. Changes in product specifications The specifications given in the catalogs, manuals or technical documents are subject to change without prior notice.

6. Product application (1) In using the Mitsubishi MELSEC programmable logic controller, the usage conditions shall be that the

application will not lead to a major accident even if any problem or fault should occur in the programmable logic controller device, and that backup and fail-safe functions are systematically provided outside of the device for any problem or fault. (2) The Mitsubishi programmable logic controller has been designed and manufactured for applications in general

industries, etc. Thus, applications in which the public could be affected such as in nuclear power plants and other power plants operated by respective power companies, and applications in which a special quality assurance system is required, such as for Railway companies or Public service purposes shall be excluded from the programmable logic controller applications. In addition, applications in which human life or property that could be greatly affected, such as in aircraft, medical applications, incineration and fuel devices, manned transportation, equipment for recreation and amusement, and safety devices, shall also be excluded from the programmable logic controller range of applications. However, in certain cases, some applications may be possible, providing the user consults their local Mitsubishi representative outlining the special requirements of the project, and providing that all parties concerned agree to the special circumstances, solely at the users discretion.

Page 123 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — Warranty
Page 123 · click to enlarge
Page 123
Page 123 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — Warranty
Page 124 of the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) user manual — Warranty
Page 124 · click to enlarge
Page 124
Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) — Warranty diagram (page 124)
Fig. 139 · Warranty
Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
303Reduce the number of objects p.98
306Download the screen data to the built-in memory p.98
307Determine object monitoring devices p.98
308Create the comment file and download it to the GOT p.98
309Correct device p.98
310(1) Specify the existing base screen/window screen. (2) Specify the existing base screen/window screen. p.98
311Reduce the alarms in the alarm history (Remove the history recovered) p.98
3121. Establish "Clear trigger" set for the scattered chart. 2. Set "Operation at frequency over time" of the scattered chart for "Initialize and continue". p.98
315Correct device p.98
316Reconsider the data operation formula so that the operation result does exceeded the range which can be represented by the device type p.98
320Confirm the part number specified for the part dis- play in the screen data p.98
321Confirm the monitor destination station number in the screen data p.99
322Set the monitored PLC CPU and parameters to set the device in the monitorable range p.99
324Incorporate the AD51H into the system or stop monitoring of the AD51H-dedicated device p.99
325Check the loading status of the specified special module p.99
330Check the capacity p.99
3311. Load the PC card 2. Turn ON the access switch p.99
332Format the PC card p.99
333Make the PC card write-enabled p.99
334Change the PC card p.99
335Change the battery of the PC card p.99
3401. Check the printer 2. The Printer switch it on p.99
3421. If external power (24VDC) is not supplied, sup- ply external power. 2. If external power is supplied, change the exter- nal I/O interface module. p.99
343Mount the external I/O interface module properly. p.99
3451. Change the device data to be displayed into a BCD value 2. Enter the value of 4-digit integer p.99
3501. Check for an unplugged communication cable connector 2. check the cables used p.99
3511. Check recipe file data in PC card 2. Start GOT after deleting recipe file in PC card p.99
352Start GOT after loading PC card p.99
3531. Check write protect of PC card 2. Check PC card capacity 3. Do not unload PC card during recipe operation p.99
354Do not unload PC card during recipe operation p.99
3551. Do not unload PC card during recipe operation 2. Check recipe file data (device values) in PC card p.99
3561. Check the file register name, and then operate the recipe function again. 2. Apply Format PLC memory to the designated PLC drive with the GX Developer, and then operate the recipe function again. p.100
3571. Check the designated PLC drive, and then oper- ate the recipe function again. 2. Apply Format PLC memory to the designated PLC drive with the GX Developer, and then operate the recipe function again. p.100
3581. Check the designated PLC drive/ file register name, and then operate the recipe function again (If drive 0 was designated, change to a different drive, and then operate the recipe func- tion again). 2. Check whether the memory card is write-pro- tected, and then operate the recipe function again. p.100
359Wait until the peripheral devices finish operating, and then operate the recipe function again. p.100
360Reconsider the data operation formula to avoid the divisor of 0 p.100
370Check the upper and lower limit value setting and correct them to be [upper limit lower limit] p.100
4021. Check for any disconnected cable or improperly fitted communication board/communication module 2. This may occur if the programmable logic con- troller load is increased while accessing another station. In this case, move the other station's data to the local station's programmable logic controller, and monitor with the local station. 3. If the sequence scan is long, insert a COM com- mand. p.100
403Check the cable connection status, the communi- cation board/communication module mounting sta- tus, the PLC status, and the communication link transmission speed. p.100
406Check the station number of the monitor screen data. p.100
407Check the network number in the screen data to avoid access to the other network p.100
421Set the PLC side Ethernet module for write enable. p.100
422Check the CPU for any fault using GX Developer or like. (Check the buffer memory.) p.100
22(1) The scanning time exceeds the calculation congestion monitoring time. (2) The scanning time may be extended by waiting for a response from an SP module that is down, and errors may occur simultaneously.When an End instruction is exe- cuted p.106
31The information stored in the cards of the module installed in the base module and the communication module of the GOT is different from that read at the initial time. (If an error occurs on a module (vacant) other than that installed in the base module, the mis-opera- tion may be caused by noise.)When an End instruction is exe- cuted p.106
40When the FROM/TO instruction is executed, an imprecise response is returned from the special func- tion module (including the GOT).During execution of FROM/TO instruc- tion set p.106
41The special function module was accessed during the execution of a FROM/TO instruction set, but there was no response.During execution of FROM/TO instruc- tion set p.106
43An imprecise interrupt occurs to the PLC CPU.During interrupt p.106
44Too many modules are installed (see the PLC CPU specification).At CPU power ON/ At reset p.106
46The FROM/TO instruction is exe- cuted to any module other than the special function module.During execution of FROM/TO instruc- tion set p.106
1310An imprecise interrupt occurs to the PLC CPU.During interrupt p.107
1401There was no response from the intelli- gent function module during initial com- munications stage. • The size of the buffer memory of the intelligent function module is abnormal.At CPU power ON/ At reset/When intel- ligent function mod- ule is accessed. p.107
1402The intelligent function module was accessed in the program, but there was no response.When an intelligent function module access instruction is executed. p.107
1403There was no response from the intelli- gent function module when the END instruction is executed. • An error is detected at the intelligent function module.When an End instruction is exe- cuted p.107
1411At the time of initial communication, an imprecise response is returned from the special function module (including the GOT).At CPU power ON p.107
1412When the FROM/TO instruction is exe- cuted, an imprecise response is returned from the special function module (includ- ing the GOT).During execution of FROM/TO instruc- tion set p.107
2000The information stored in the cards of the module installed in the base module and the communication module of the GOT is different from that read at the initial time. (If an error occurs on a module (vacant) other than that installed in the base mod- ule, the mis-operation may be caused by noise.)When an End instruction is exe- cuted p.107
2100(1) In the parameter I/O allocation set- tings, an intelligent function module was allocated to a location reserved for an I/O module. Or, the opposite has happened. (2) In the parameter I/O allocation set- tings, a module other than CPU (or noth- ing) was allocated to a location reserved for a CPU module. Or, the opposite has happened. (3) A general-purpose switch was set to the module with no general-purpose switches.At CPU power ON/ At reset p.108
2101 to 2103The modules more than those specified in the PLC CPU specification are installed. p.108
2104At the MELSECNET/MINI auto refresh parameter settings, the module allocation that was set is different from the actual module models at the station numbers in the link system. p.108
2105There are too many special function mod- ules that can use dedicated instructions allocated (number of modules installed). p.108
2106(1) 5 or more QJ71LP21/BR11 have been installed. (2) 5 or more QJ71E71 (-B2) have been installed. (3) Identical network numbers or station numbers exist in the MELSECNET/10 network system. p.108
2107Head X/Y set at the parameter I/O alloca- tion settings is also the head X/Y for some other module. p.108
2108(1) Network module A1SJ71LP21, A1SJ71BR11, A1SJ71AP21 , A1SJ71AR21, or A1SJ71AT2 B dedi- cated for the A2USCPU has been installed. (2) Network module A1SJ71QLP21 or A1SJ71QBR11 dedicated for the Q2AS has been installed. Change the network module to QJ71LP21 or QJ71BR11. p.108
2109The control system and standby system module configurations are different when a redundant system is in the backup mode. p.108
2110The FROM/TO instruction is executed to any module other than the special func- tion module.When instruction executed p.109
2111The location designated by link direct device (J / ) is not a network module. p.109
2112(1) The location designated by a special function module dedicated instruction is not a special function module. (2) Alternatively, it is not the relevant special function module.When instruction executed/ STOP RUN p.109
2113No special function module data for simu- lation purposes has been set in the simu- lation data. p.109
2120The location of Q B and QA1S B is improper.At CPU power ON/ At reset p.109
2122QA1S B is installed to the basic base unit. p.109
5000Program scan time for initial execution type program goes over the initial execu- tion WDT time set in the parameter PC RAS settings.Always p.109
5001Program scan time goes over the WDT value set in the parameter PC RAS set- tings. p.109

Ask about the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Mitsubishi Electronics Touchscreen Operator Interface (A951GOT)

Be the first to ask — other owners or our team will answer.

Original document

Mitsubishi Electronics Touchscreen Operator Interface (A951GOT) manual PDF

124 pages·4.4 MB·Stereo Equalizer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…