Instruction/ maintenance manual of the product SR35 Midas Consoles
Go to page of 14
MIDAS experiment „alc“ USER MANUAL SR35, 05.07.2006 Data acquisition is running on psw407 (DELL Power Edge 2600). AFS users can logon to pc5145, the local user account is l_musr_alc . Data files are stored locally on psw407 in /home/l_musr_alc/exp/alc and automatically copied to /afs/psi.
start web browser: http://psw407:8080 (PSI only!): Status page (the following screenshots are taken from pc4244…) DO NOT USE ‘Konqueror’ !!!! (only IE, Mozilla, or Firefox).
Start a run for autorun sequence: set autorun_active = 1 (if 0: only single run) there are no ‘scans’ anymore!.
Stop a run Do not interfere the stop ping proced ure – wait until the pages refreshes and shows sta tus ‘stopped’..
Set Magnet change Demand value read Hall probe read NMR probe - field >= 0.0 * - probe is locked * - readout unit is Tesla * - sum of returned errors (returned value < 0.0) * status unit * -1.0 BUS DRIVER I/O TIMEOUT I * -2.0 BUS DRIVER ERROR B * -4.
Set Temperature LTC21: Input: read values Output : set value LTC21_Analog_Set_Point (K).
Set Flow Demand = 3000 for T = 0 – 100 ° C, set Demand = 10000 for cooling down, base temp. ???.
History.
ODB: DO NOT TOUCH! – discuss with Instrument Scientist first Start frontends from term inal by running the command alc_start_midas Shutdown all frontends: alc_mcleanup [l_musr_alc@pc4244 alc]$ alc_mcleanup Midas cleanup procedure for experiment ALC.
mozilla-bin: no process killed killing opera... opera: no process killed Cleaning up shared memory segments for user l_musr_alc ... Cleaning up semaphores for user l_musr_alc .
Separator : vncviewer sepii:0 , pw: exhalle - if only black screen appears use rdesktop sepii , user: halle, pw: exhalle under winXP: Remote Desktop Connec tion (All Programs – Accessories – Communications) for HV = 150 kV: SEP = 746 The beamline setting is nam ed ALC2005_1st_period.
Data written as ASCII file : alc_05_NNNN.dat (run number NNNN) format: 19 header lines followed by data, lines containing 48 coloumns each !File: /home/l_musr_alc/exp/alc/alc_05_0270.
Appendix: Some ODB entries Ip_min is the minimum required beam current on Target E in mA. Measurement is paused when the current is lower. rate_min is the minimum required positron rate in the sum of the backward counters (this makes sure that the run is automatically paused when the beam blocker is closed).
Ip_channel is the channel number (starting at 0, in the above example this is the third channel) of the proton beam current signal, 100 kHz correspond to 1 mA. preset channels is the bitmask for the scaler cha nnels used f or the preset counting register in hex form.
An important point after buying a device Midas Consoles SR35 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Midas Consoles SR35 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Midas Consoles SR35 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Midas Consoles SR35 you will learn all the available features of the product, as well as information on its operation. The information that you get Midas Consoles SR35 will certainly help you make a decision on the purchase.
If you already are a holder of Midas Consoles SR35, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Midas Consoles SR35.
However, one of the most important roles played by the user manual is to help in solving problems with Midas Consoles SR35. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Midas Consoles SR35 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center