Instruction/ maintenance manual of the product MPE-33R Maytag
Go to page of 20
33" Electric Fireplace P/N 850,032M REV . B 06/2006 MODEL: SA VE THESE INSTRUCTIONS FOR FUTURE REFERENCE MERIT PLUS SERIES This manual will enable you to obtain a safe, effi cient and dependable installation and operation of your electric fi replace.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 2 INTRODUCTION This Electric Fireplace is designed for residential applications to be framed in as a fi replace. This appliance has been tested in accor - dance with UL 2021 and CSA C22.2 No. 46-M198 standards for fi xed and location dedicated electric room heaters.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 3 Figure 1 TOOLS AND BUILDING SUPPLIES NORMALL Y REQUIRED T ools: Phillips Screwdriver 7/16" Socket Drive Hammer Saw And/or Saber Saw Level Measu.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 4 FRAMING SPECIFICA TIONS 34-1/2" (876 mm) 21-1/8 " (537 mm) 14-7/8" (32 mm) 5-1/8 " (130 mm) 33 " (838 mm) 2-1/4 " (55 .
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 5 MINIMUM CLEARANCES TO COMBUS- TIBLES Mantel Clearance: Combustible and Non-com- bustible mantels may be installed at any height above the top of the face of fi replace. Cat. No. H3427 Model: MPE-33R Description: Merit Plus Electric Fireplace, 33” Radiant Shipping Weight: 81 lb.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 6 MANUAL CONTROL P ANEL Main Power On/Off (rear most switch) Figure 4 FINAL FINISHING Materials such as brick and tile can be extended down to the top of the fi replace. Do not extend down, covering the outlet or glass enclosure panel (optional kit).
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 7 • When using the remote control , the power on/off switch inside the body and the wall switch (optional kit) must be on the OFF position. REMOTE CONTROL OPERA TION: Figure 6 The Merit Plus Electric Fireplace is provided with an Infrared l ight R emote Control.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 8 Figure 9 MAINTENANCE This appliance has been designed to provide many years of trouble-free service. The com- ponents that will need to be serviced have been kept to a minimum. Periodic dusting of the fi replace is all that should be required.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 9 Replacing Light Bulbs b. Flame Cylinder Bulbs i. Remove Brick panel, following proce- dure on Page 8 (see Brick panel Removal Procedure ). Figure 12 Ember Bed Ember Bed Figure 16 Figure 17 Figure 18 Brick Panel Retaining brackets iii.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 10 10 WIRING DIAGRAM - 120 VOL T Wiring diagrams are provided here for reference purposes only . This information is also provided on schematics attached directly to the appliance on the left side. CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 11 WIRING DIAGRAM - 240 VOL T Wiring diagrams are provided here for reference purposes only . This information is also provided on schematics attached directly to the appliance on the left side. CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 12 5 V GROUND INSIDE POWER ON/OFF SWITCH (ON CONTROL PANEL) POWER ON/OFF SWITCH (OPTIONAL WALL SWITCH) OUTSIDE RED RED GREEN 1K POTENTIOMETER 5 V GROU.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 13 Wall Thermostat Black 5 V Left Side of Fireplace Installing Wall Thermostat (optional kit, see Page 18) Wire the wall thermostat prior to installing the fi replace. WALL THERMOST A T WIRING (24 VAC): Install Wall Thermostat per instructions provided with kit and per the following information: 1.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 14 Power On/Off Wall Switch Installation (optional kit, see Page 18) Wire the wall switch prior to installing the fi replace. WALL SWITCH WIRING (24 V AC): Install Wall Switch per instructions provided with kit and per the following information: 1.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 15 TROUBLESHOOTING SYMPTOM POSSIBLE CAUSES WHO PERFORMS CORRECTIVE ACTIO N CORRECTIVE ACTIO N 1. Fireplac e turns off and will not tu rn on. Fireplace ha s overheat ed. Homeowne r The applianc e is prot ected with a safety dev ice to prev ent it fro m overheatin g.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 16 REPLACEMENT P ARTS ITEM NO. DESCRIPTION MPE-33R CA T . NO. QTY 1 Bulb Kit, (10 Each 35w Halogen) H1623 1 2 Side Frames, 1 Left And 1 Right H1942 1 .
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 17 REPLACEMENT P ARTS COMPONENT DIAGRAMS - MPE-33R 8b 14 16 11 1 4 2 5 6 6 7 12 13 15 23 17 19 8a 3 20 1 9 Front View 18 POWER ON/OFF DISPLAY ON/OFF Dimmer Brighter EMBERS HEATER ON/OFF TEMP. CONTROL HIGH MED.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 18 ACCESSORY COMPONENTS The following items are available for use with this appliance. Cat. No. Model Description H3430 GEP-33BL Glass Enclosure Panel, Black on Bronze H3433 GEP-33PB Glass Enclosure Panel, Brass on Bronze H3434 GEP-33BS Glass Enclosure Panel, Stainless on Bronze Cat.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 19 NOTE: THIS PAGE LEFT BLANK INTENTIONALL Y.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. Printed in U.S.A. © LENNOX HEARTH PRODUCTS 2005 P/N 850,032M REV . B 06/2006 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products.
An important point after buying a device Maytag MPE-33R (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Maytag MPE-33R yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Maytag MPE-33R - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Maytag MPE-33R you will learn all the available features of the product, as well as information on its operation. The information that you get Maytag MPE-33R will certainly help you make a decision on the purchase.
If you already are a holder of Maytag MPE-33R, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Maytag MPE-33R.
However, one of the most important roles played by the user manual is to help in solving problems with Maytag MPE-33R. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Maytag MPE-33R along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center