Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.


– Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
– Installation and service must be performed by a qualified installer, service agency, or
the gas supplier.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
In the State of Massachusetts, the following installation instructions apply:
Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
If using a ball valve, it shall be a T-handle type.
A flexible gas connector, when used, must not exceed 3 feet.

TOOLS AND PARTS
Gather the required tools and parts before starting installation.

8" or 10" pipe wrench 8" or 10" adjustable wrench (for gas connections)
Flat-blade screwdriver #2 Phillips screwdriver
Pipe-joint compound resistant to LP gas
Wire stripper (direct wire installations)
Tin snips (new vent installations)
Vent clamps 1/4" nut driver (recommended)
“Y” connector Short inlet hose
Long inlet hose Rubber washer
Caulking gun and compound (for installing new exhaust vent)
Parts package is located in dryer drum. Check that all parts are included.
Check local codes. Check existing electrical supply and venting. See “Electrical Requirements” and “Venting Requirements” before purchasing parts.
Check code requirements. Some codes limit, or do not permit, installing dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.
Adjustable wrench that opens to 1" (25 mm) or hex-head socket wrench
Refer to your Use and Care Guide for information about accessories available for your dryer.



You will need:
See “Venting Requirements.”
located within 2 ft. (610 mm) of either side of dryer. See “Electrical Requirements.”
Also consider weight of companion appliance.
valves, and water pressure of 20-100 psi (137.9-689.6 kPa). You may use the water supply for your washer using the “Y” connector and short hose (if needed) which are provided.
Side view:

dryer. If slope is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. If not level, clothes may not tumble properly and automatic sensor cycles may not operate correctly.
above floor. If using a pedestal, you will need 18" (460 mm) to bottom of dryer.
For each arrangement, consider allowing more space for ease of installation and servicing; spacing for companion appliances and clearances for walls, doors, and floor moldings. Space must be large enough to allow door to fully open. Add spacing on all sides of dryer to reduce noise transfer. If a closet door or louvered door is installed, top and bottom air openings in door are required.

Back view:



Installation spacing for recessed area or closet installation All dimensions show recommended spacing allowed, with tested spacing of 0" (0 mm) clearance on sides and rear.
installation and servicing.
floor moldings.
dryer to reduce noise transfer.
openings in the top and bottom of the door are required. Louvered doors with equivalent ventilitation openings are acceptable.

For gas dryers mobile home installations:
346764 is available to order. For further information, see "Assistance or Service" section in your Use and Care Guide.


Failure to do so can result in death or electrical shock.
It is your responsibility:

conformance with Canadian Electrical Code, C22.1-latest edition and all local codes. A copy of above codes standard may be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
60 Hz, AC only electrical supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit.
Power Cord intended to be plugged into a standard 14-30R wall receptacle. The cord is 5 ft. (1.52 m) long. Be sure wall receptacle is within reach of dryer’s final location.
Mobile home - Additional installation requirements: This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile home construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH.
If using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 9831317.
All dryers:
from your dealer. For further information, see “Assistance or Service” section in your Use and Care Guide.
introduce outside air into dryer. Openings (such as a nearby window) should be at least twice as large as dryer exhaust opening.
4-wire receptacle (14-30R)

For further information, please reference service numbers located in “Assistance or Service” section of your Use and Care Guide.
For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment- grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment- grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
GAS SUPPLY REQUIREMENTS
GAS DRYER POWER HOOKUP ELECTRICAL REQUIREMENTS
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas pressure does not exceed 13" (330 mm) water column.
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
Failure to do so can result in death, explosion, or fire.
supply is required. A time-delay fuse or circuit breaker is recommended. It is also recommended that a separate circuit serving only this dryer be provided.
This dryer is equipped for use with Natural gas. It is design- certified by CSA International for LP (propane or butane) gases with appropriate conversion.
Explosion Hazard · Electrical Shock Hazard

in your home. Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, contact your dealer or call the phone numbers referenced in the “Assistance or Service” section of your Use and Care Guide.
between the flexible gas connector and the dryer gas pipe, as needed to avoid kinking.
listed flexible gas connector that complies with the standard for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
No attempt shall be made to convert the dryer from the gas specified on the model/serial rating plate for use with a different gas without consulting your gas company.
of the burner Btu rating shown on the model/serial number plate is required for each 1,000 ft. (305 m) increase in elevation.
for test gauge connection, immediately upstream of the gas connection to the dryer.
system during pressure testing at pressures greater than 1/2 psi.
D
B
DRYER GAS PIPE
A. 3/8" flexible gas connector B. 3/8" pipe to flare adapter fitting C. 1/8" NPT minimum plugged tapping D. 1/2" NPT gas supply line E. Gas shutoff valve.
has a 3/8" male pipe thread.
A *6¼" (159 mm)
lengths under 20 ft. (6.1 m) if local codes and gas supplier permit.
a different size adapter fitting.
A. 3/8" NPT dryer pipe
*NOTE: If the dryer is mounted on a pedestal, the gas pipe height must be an additional 10" (254 mm) or 15.5" (394 mm) from the floor, depending on the pedestal model. For a garage installation, the gas pipe height must be an additional 18" (460 mm) from the floor.
compatible copper tubing can be used. If the total length of the supply line is more than 20 ft. (6.1 m), use larger pipe.
In the U.S.A.:
An individual manual shut-off valve must be installed within six (6) ft. (1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. The location should be easy to reach for opening and closing.
In Canada:
An individual manual shut-off valve must be installed in accordance with the B149.1, Natural Gas and Propane Installation Code. It is recommended that an individual manual shutoff valve be installed within six (6) ft. (1.8 m) of the dryer. The location should be easy to reach for opening and closing.
†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
1½" (38 mm)

Venting REQUiREMENTS

that may obstruct exhaust (such as flowers, rocks, bushes, or snow).
A
Failure to follow these instructions can result in death or fire.
Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or flexible metal vent shall be used for exhausting.
vent and clamps may be used.
Good Better Clamps:
crushing and kinking.
or other fastening devices that extend into interior of duct and catch lint. Do not use duct tape.

result in reduced airflow and poor performance.
Improper venting can cause moisture and lint to collect indoors, which may result in:
Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.
Vent products can be purchased from your dealer. For more information, see “Assistance or Service” section in your Use and Care Guide.
2½" (64 mm)



Over-the-top installation (also available
with one offset elbow)


Special provisions for mobile homes: Exhaust vent must be securely fastened to a noncombustible portion of mobile home and must not terminate beneath the mobile home. Terminate exhaust vent outside.
Failure to follow these instructions can result in death or fire.

Dryer may be converted to exhaust out right side, left side, or through bottom. If you prefer, you may contact your local dealer to have dryer converted.
outdoors.
as possible.
Standard rear-exhaust hook-up


Connect vent to exhaust hood 2.
material and hood combinations acceptable to use.

Exhaust systems longer than those specified will:
and increased energy usage.
The Vent system chart provides venting requirements that will help achieve best drying performance.
Vent must fit over the exhaust hood. Secure vent to exhaust hood with 4" (102 mm) clamp. Run vent to dryer location using straightest path possible. Avoid 90° turns. Use clamps to seal all joints. Do not use duct tape, screws, or other fastening devices that extend into interior of vent to secure vent, because they can catch lint.


Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.

Prepare dryer for leveling legs 3.


To avoid damaging floor, use a large flat piece of cardboard from dryer carton; place under entire back edge of dryer. Firmly grasp dryer body (not console panel) and gently lay dryer down on cardboard.
Excessive Weight Hazard


Open shut-off valve in supply line; valve is open when handle is parallel to gas pipe. Then, test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak. Correct any leaks found.
Examine leveling legs, find diamond marking. Screw legs into leg holes by hand, use a wrench to finish turning legs until diamond marking is no longer visible.
Now stand the dryer on its feet. Slide the dryer until it is close to its final location. Leave enough room to connect the exhaust vent.
The dryer must be connected to the cold water faucet using the new inlet hoses. Do not use old hoses.

Turn cold water off, remove and replace rubber washer 8.

Connect gas supply to dryer 5.


A. Flared male fitting B. Non-flared male fitting
Remove red cap from gas pipe. Using a wrench to tighten, connect gas supply to dryer. Use pipe-joint compound on threads of all non-flared male fittings. If flexible metal tubing is used, be sure there are no kinks.
Turn cold water faucet off and remove washer inlet hose.
Check and see if rubber washer is in the “Y” connector. Remove old rubber washer from inlet hose and replace with new rubber washer provided.


Plan pipe fitting connection 6.
Attach short hose and “Y” connector 9.


A
B C
A. 3/8" flexible gas connector B. 3/8" dryer pipe
C. 3/8" to 3/8" pipe elbow D. 3/8" pipe-to-flare adapter fitting
If space permits, attach the brass female end of the “Y” connector to the cold water faucet. See figure A.
A combination of pipe fittings must be used to connect dryer to existing gas line. A recommended connection is shown. Your connection may be different, according to supply line type, size, and location.
If “Y” connector cannot be attached directly to the cold water faucet, the short hose must be used. See figure B. Attach short hose to cold water faucet. Screw on coupling by hand until it is seated on faucet. Then attach “Y” connector to brass male end of the short hose. Screw on coupling by hand until it is seated on connector.
†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.

Tighten couplings 10.
Attach long hose to dryer fill valve and tighten coupling 12.


Using pliers, tighten the couplings with additional two-thirds turn.

Attach long hose to “Y” connector and tighten couplings 11.
Attach other end of long hose to fill valve at bottom of dryer back panel. Screw on coupling by hand until it is seated on fill valve connector. Using pliers, tighten the couplings an additional two-thirds turn.

Turn on cold water faucet 13.

One end of the long hose has a wire mesh strainer inside the coupling. Attach this end to the “Y” connector. Attach washer cold inlet hose to other side of “Y” connector. Screw on coupling by hand until it is seated on connector. Using pliers, tighten the couplings an additional two-thirds turn.
Check that the water faucets are turned on.
Check for leaks 14.
Check for leaks around “Y” connector, faucet, and hoses.

Level dryer
Level Dryer 17.
Connect vent to exhaust outlet 15.

Using a 4" (102 mm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure vent is clean. Dryer vent must fit over dryer exhaust outlet and inside exhaust hood. Check that vent is secured to exhaust hood with a 4" (102 mm) clamp.
Check levelness of dryer from side to side. Repeat from front to back.
Move dryer to final location 16.
Not Level LEVEL Not Level

Tighten and adjust leveling legs 18.
Move dryer to final location. Avoid crushing or kinking vent. After dryer is in place, remove corner posts and cardboard from under the dryer.
If dryer is not level, prop up using a wood block, use wrench to adjust legs up or down, and check again for levelness. Once legs are level, make sure all four legs are snug against the ground before tightening them.
Place level here

Complete Installation CHECKLIST q Check that all parts are now installed. If there is an extra
If dryer will not start, check the following:
part, go back through steps to see what was skipped. q Check that you have all of your tools. q Dispose of/recycle all packaging materials. q Be sure the water faucets are on. q Check for leaks around “Y” connector, faucet, and hoses. q Check dryer’s final location. Be sure vent is not crushed
This dryer automatically runs an installation diagnostic routine at the start of its first cycle.
or kinked. q Check that dryer is level. See “Level Dryer”. q Remove film on console and any tape remaining on dryer. q Wipe dryer drum interior thoroughly with a damp cloth to
Door Reversal If you prefer to reverse the door swing on your dryer:
remove any dust. q Read “Dryer Use” in your Use and Care Guide. q If you live in a hard water area, use of a water softener is
to order. For further information, see “Assistance or Service” section in your Use and Care Guide.
recommended to control the buildup of scale through the water system in the dryer. Over time, the buildup of lime scale may clog different parts of the water system, which will reduce product performance. Excessive scale buildup may lead to the need for certain part replacement or repair.
See the Use and Care Guide or visit our website and reference Frequently Asked Questions to possibly avoid the cost of a service call...
Electric Models: q Plug into a grounded outlet.
Gas Models: q Check that gas supply is on. q Check for leaks.