Revision 1.2 Page i ® ® ACM100 Alternating Current Monitor User’s Manual Revision 1.2 Copyright © 2012 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N.
ACM100 User’s Manual Page ii Revision 1.2 Revision History Revision Description 1.0 Original document 1.1 Corrected AC sensor part number Updated mounting drawing 1.
Revision 1.2 Page iii ® ® Table of Contents 1 Introduc tion .................................................................................................................. ......... 1 1.1 Firmware Revi sion ...........................
ACM100 User’s Manual Page iv Revision 1.2 Figure 4 – Single-Phase (Dual Line) Connecti on Diagram ........................................................ 6 Figure 5 – Three-Phase Connection Di agram .........................................
Revision 1.2 Page 1 ® ® 1 Introduction Congratulations on your purchase of the Maretr on Alternating Current (A C) Monitor (ACM100). Maretron has designed and built your ACM100 to the highest standards for years of dependable and accurate service.
ACM100 User’s Manual Page 2 Revision 1.2 o 230VAC single phase o 380VAC Y Three-phase (380Y) 1.3 Quick Install Installing the Maretron ACM100 invo lves the following five steps. Please refer to the individual sections for additional details. 1. Unpack the box (Section 2.
Revision 1.2 Page 3 ® ® 2.3 Mounting the ACM100 Attach the ACM100 securely to the vessel usi ng the included stainless steel mounting screws or other fasteners as shown in Figure 1 below . Do not use threadlocking compounds containing methacrylate ester, such as Loctite Red (271), as they will cause stress cracking of the plastic enclosure.
ACM100 User’s Manual Figure 2 – NMEA 2000 ® Connector Face Views 2.4.2 AC Sensor Connections The ACM100 sensor connections are made by connecting to the 12-pin terminal strip on the top of the unit. First, remove the four screws at the corners of the unit det aching the splash guard from the unit.
® ® WARNING: If the supplied current transformer is plac ed around a wire carrying AC current, then extremely high voltages can develop on the output leads of the current transformer, with severe risk of el ectrocution.
ACM100 User’s Manual a. Connect the black wire to pin 7 (I A+ ) on the ACM100 b. Connect the white wire to pin 8 (I A- ) on the ACM100 c. Disconnect the hot wire from the AC power source and plac e it through the hole in the Current Sensor such that the arrow on the Current Sensor points towards the AC power source.
Revision 1.2 Page 7 ® ® will need to purchase an optional cu rrent sensor (Part # M000630) fo r monitoring this type of system. Step 1: De-energize the AC Source. Step 2: The Current Transformer has black and wh ite wires. Install the Phase A Current Transformer as follows: a.
ACM100 User’s Manual 2.4.2.3 Three-Phase (Phase A, B, C) Connection Please refer to Figure 5 for connecting the ACM100 to a three phase system. Page 8 Revision 1.
Revision 1.2 Page 9 ® ® c. Disconnect the Phase B hot wire from the AC power sour ce and pl ace it through the hole in the Current Sensor such that the arrow on t he Current Sensor points towards the AC power source. Then, reattach the Phase B hot wire to the AC power source.
ACM100 User’s Manual Page 10 Revision 1.2 c. Connect the black wire from one end of the second Voltage Sense cable to pin 3 (V CLine ) on the ACM100 d. Connect the black wire from the other end of the second Voltage Sense cable to a fuse appropriately sized for the black wire (18 gauge wire minimum and 3 amp fuse or less).
Revision 1.2 Page 11 ® ® 2.5.3 AC Circuit Type You must configure the ACM100 as to what type of AC circuit connection it is monitoring. The allowable values for this parameter are as follows: • Si.
ACM100 User’s Manual Page 12 Revision 1.2 reconnecting the current transformer, you may c hange the value of this parameter from the default value of “Normal Install” to “I nverse Install” to correct for this.
Revision 1.2 Page 13 ® ® 3.1 Line-Specific and Line-to-Neutral Measurements Parameter AC Source Type Available Data Bus Generator Utility Average Phase A Phase B Phase C Line-Neutral AC RMS Voltage .
ACM100 User’s Manual Page 14 Revision 1.2 • Clean the unit with a soft cloth. Do not use chemical cleaners as they may remove paint or markings or may corrode the ACM 100 enclosure or seals. Do not use any cleaners containing acetone, as they will deteriorate the plastic enclosure.
Revision 1.2 Page 15 ® ® 6 Technical Specifications As Maretron is constantly impr oving its products, all specificat ions are subject to change without notice.
ACM100 User’s Manual Page 16 Revision 1.2 Electrical Parameter Value Comment Sensed Voltage 0-240 VAC 120,120/240,240,208Y,380Y configu rations Sensed Current 0-200 A With supplied current transformer Operating Voltage 5 to 36 Volts DC Voltage Power Consumption 100 mA NMEA 2000 ® Interface Load Equivalence Number (LEN) 2 NMEA 2000 ® Spec.
® ® 8 Installation Template Please check the dimensions before using the fo llowing diagram as a template for drilling the mounting holes because the printing proc ess may have distorted the dimensions. Figure 6 – Mounting Surface Template Revision 1.
ACM100 User’s Manual Page 18 Revision 1.2 9 Maretron (2 Year) Limited Warranty Maretron warrants the ACM100 to be free from defects in materials and workm anship for two (2) years from the date of original purchase.
Revision 1.2 Appendix A – NMEA 2000 Interfacing Page A1 ® ® Appendix A – NMEA 2000 ® Interfacing ACM100 NMEA 2000 ® Periodic Data Transmitted PGNs PGN 65001 – Bus #1 Phase C Basic AC Quantit.
ACM100 User’s Manual Page A2 Appendix A – NMEA 2000 Interfacing Revision 1.2 PGN 65005 – Utility Total AC Energy PGN 65018 – Generator Total AC Energy The ACM100 uses this PGN to transmit the total energy delivered by the power source.
An important point after buying a device Maretron ACM100 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Maretron ACM100 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Maretron ACM100 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Maretron ACM100 you will learn all the available features of the product, as well as information on its operation. The information that you get Maretron ACM100 will certainly help you make a decision on the purchase.
If you already are a holder of Maretron ACM100, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Maretron ACM100.
However, one of the most important roles played by the user manual is to help in solving problems with Maretron ACM100. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Maretron ACM100 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center