Instruction/ maintenance manual of the product 360DVSR Majestic Appliances
Go to page of 44
PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING APPLIANCE IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard, and will void the warranty .
2 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 Installation and Operating Instructions ........................................................................................................ 3 Important Curing/Burning Instructions ........
3 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 T hi s g as ap pl i an c e sh o ul d b e i ns t al le d b y a q u al i fie d i ns t al le r , preferably NFI or WETT (Canada) certified, i n ac c or d an ce w it h l oc a l bu i ld i ng c o de s a nd cu r re nt CS A -B 14 9 .
4 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 Requirements for the Commonwealth of Massachusetts All gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber .
5 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 J J K K H D A E B I E A F C H 6326 360DVS2 top vent specs Electrical Access Gas Line Access Electrical Access Gas Line Acc.
6 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 I J K K ROD 6326 360DVS3 rear vent specs B E C G F D A H H B Electrical Access Gas Line Access C K J J I J K K 6326 360DVS3 top vent spe.
7 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 ROH ROD ROW CFM121 360DVS2 REAR VENT CONFIGURATION 8/10/00 Framing Dimensions - 360DVS2 CFM122 360DVS2 - TOP VENT CONFIGURATION 8/10/00 ROD ROH ROW Rear V ent Configuration T op V ent Configuration CFM121 CFM122 Framing Dimensions Ref.
8 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 CFM123_360DVS3_dims_RV2 REAR VENT CONFIGURATION 8/10/00 rev. 8-23-02 rjs ROD ROW ROD ROH ROH ROH ROD 360DVSL 360DVS/3/L/R 360DVS3 360DVSR CFM124_360DVS3_TV2 TOP VENT CONFIGURATION 8/10/00 rev.
9 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 T op of unit to ceiling ................................. 36” (914 mm) Front of unit to combustibles ................... 36” (914 mm) Appliance T op .........................................
10 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 A hearth is not mandatory; however , for aesthetic purposes, we recommend installing a noncombustible hearth that projects out 12” (305mm) or more from the front of the fireplace.
1 1 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 FP297A INST A VENT FREE UVHB26 GAS SUPPL Y 7/1/98 1/2” Gas Supply 1/2” NPT X 1/2” Flare Shut-Of f V alve 3/8” Flex Line (From V alve) FP297a Fig. 5 Gas shutoff valve and flex connector .
12 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 FP1430 Fig. 8 Alternate switch location. Optional T op V ent Application This appliance is shipped as a rear vent unit. If the installation layout requires the unit to be a top vent con- figuration, the appliance can be converted by following the steps below .
13 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 Electronic Gas Control V alve This appliance may be fitted with a Honeywell ignition module. Installation of the remote ON/OFF starter switch on electronic ignition units (Fig. 12): 1. Thread the wiring through the holes on the side panels of the appliance.
14 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINA TION AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Operable Operable Fixed Closed V B CFM145a DV T ermin Location 5/01/01 Rev .
15 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 Fig. 14 T ermination clearances. General Information Assembling V ent Pipes Canadian Installations: V enting system must be installed in accordance with the current CSA-B149.1 installation code.
16 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 How to Use the V ent Graph The vent chart should be read in conjunction with the following vent installation instructions to determine the relationship of the vertical and horizontal dimensions of the vent system.
17 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 VO584-100 V ent Opening 2/99 djt V ent Opening for Combustible W all 9 ³⁄₈ ” (240mm) 10 ³⁄₈ ” (265mm) Framing Detail V ent Opening for Noncombustible W all 7 ¹⁄₂ ” (190 mm) VO584-100 Fig.
18 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 Horizontal plane means no vertical rise exists on this portion of the vent assembly . • The maximum number of 90˚ elbows per side wall installation is three (3).
19 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 STEP 3 Place fireplace into position. (Fig. 26) Measure the verti- cal height (X) required from the base of the flue collars to the center of the wall opening.
20 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 2” (51 mm). Secure termination to the wall with screws provided, and caulk around the wall plate to weather- proof. One alternative to screwing the termination directly to the wallis the use of expanding plugs or an approved exterior construction adhesive.
21 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 V ertical Through-the-Roof Application This Gas Fireplace has been approved for: • V ertical installations up to 40’ (12 m) in height. Up to a 10’ (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90° elbows.
22 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 V ertical Through-the-Roof Installation 1. Locate your fireplace. 2. Plumb to center of the (4”) flue collar from ceiling above and mark position. 3. Cut an opening equal to 9 ³⁄₈ ” x 9 ³⁄₈ ” (240 x 240mm).
23 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 584B V ent components Star ter Kit 2/25/99 djt 584G V enting Components Firestop spacer 2/25/99 djt 584H V enting compone.
24 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 Operating Instructions Only glass approved by CFM Corporation should be used on this fireplace. Glass Information • The top side and top end louvres are removed by simply lifting the louvre assembly and pulling the assembly away from the fireplace.
25 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 Glass Cleaning It is necessary to periodically clean glass. During start- up, condensation, which is normal, forms on the inside of the glass. This condensation causes lint, dust and other airborne particles to cling to glass surface.
26 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 LG320 360DVS logs B120 B121 B122 B123 B124 B126 B125 LG320 Fig. 40 360DVS log placement. Side of Fireplace V enting Side V enting Side LG321 360DVS logs opposite side B120 B121 B122 B123 B126 B125 Side of Fireplace LG321 Fig.
27 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 L O H I FP390 FLAME ADJUSTMENT KNOB 1 1/21/96 T urn counterclockwise to increase flame height T urn clockwise to decrease flame height Fig. 43 Flame adjustment knob for SIT valve. Flame Characteristics It is important to periodically perform a visual check of the pilot and burner flames.
28 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 1. STOP! Read the safety information above. 2. T urn off all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances ONL Y , go on to Step 4. For RN/RP appliances turn the On/Of f switch to “OFF” position or set thermostat to lowest level.
29 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 Lighting and Operating Instructions For Fireplaces equipped with SIT822 Gas V alve (EN or EP) A. This fireplace is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand.
30 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position. SIT NOV A 820 MILLIVOL T V AL VE T roubleshooting the Gas Control System W ARNING: REMOVE GLASS FRONT BEFORE DOING ANY GAS CONTROL SERVICE WORK.
31 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 SIT 822 V alve with a Honeywell Electronic Igniter NOTE: Remove glass before servicing. ST ART TURN GAS SUPPL Y OFF . TURN ON/OFF SWITCH TO CALL FOR HEA T . POWER TO MODULE? (24V NORMAL) SP ARK ACROSS IGNITOR SENSOR GAP? YES YES YES TURN GAS ON.
32 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 T roubleshooting – Honeywell VS8421 ST ART CHECK Gas Supply On Pilot Lights With Piezo Ignitor • Lockout Has Engaged. W ait 60 Seconds And Try Again. • For Spark At Electrode While Depressing Piezo 1/8" Gap T o Pilot Hood Needed.
33 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 Fuel Conversion Instructions T o convert this appliance from gas type to another , fol- low these instructions. Before proceeding, turn control knob to “OFF” and turn gas supply OFF . T urn OFF any electricity that may be going to the appliance.
34 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 D E F FC108 SIT regulator conversion 10/03 O F F P I L O T O N FC108 Fig. 49 Replace regulator . 10. Reassemble fireplace in the reverse order , except for the window frame assembly . Leave this off until after unit has been checked for leaks and the gas supply has been bled.
35 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 Burner and Burner Compartment It is important to keep the burner and the burner com- partment clean. At least once per year remove the logs and lava rock/ember material. V acuum and wipe out the burner compartment.
36 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 L O H I PILOT ADJ PILOT ON OFF 4a/b 5a/b 6 1 1 9 1 1 8 10 7 12 18 24 27 17 2 29 28 22 23 26 21 20 25 19 13 14 3a/b 15a/b 16a/b 6326 360DVS pa.
37 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 360DVS Series (Items marked ‘*’ are not shown in the parts illustration) Ref. Description 360DVS2 360DVS3 360DVSL 360DVSR 1. Log Set (complete) 10006350 10006350 10006350 10006350 1a. Log - Rear (B120) 10006315 10006315 10006315 10006315 1b.
38 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 Ref. Description 360DVS2 360DVS3 360DVSL 360DVSR 360DVS Series (continued) (Items marked ‘*’ are not shown in the parts illustration) 21. Louvre Assembly , side bottom 10000040 10000040 10000040 10000040 22.
39 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 Optional Accessories Fan Kits FK24 Fan Assembly This auxiliary fan system increases the efficiency of the circulation of the heated air . The FK24 fan kit allows variable speed control of the circulation fan and also incorporates a heat sensor in the circuit.
40 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326 Wiring Instructions The fireplace, when installed, must be elec - trically connected and grounded in accor- dance with local codes, or in the absence of local codes, with the current CSA C22.
41 360D VS Ser ies Dir ect V e nt F ir e place s 10006326.
42 360 D VS Ser ies Dir ect V e nt F ir e place s 10006326.
43 360D VS Ser ies Dir ect V e nt F ir e place s 10006326 BASIC W ARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new V ermont Castings or Majestic Gas.
Efficiency Ratings Model EnerGuide Ratings Steady State (%) D.O.E. Fireplace Efficiency (%) Fan-OFF Fan-ON (AFUE%) 360DVS2RN 62.4 83 84 65 360DVS2RP 62.4 83 84 65 360DVS2EN 62.4 83 84 65 360DVS2EP 62.4 83 84 65 360DVS3RN 62.4 83 84 65 360DVS3RP 62.4 83 84 65 360DVS3EN 62.
An important point after buying a device Majestic Appliances 360DVSR (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Majestic Appliances 360DVSR yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Majestic Appliances 360DVSR - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Majestic Appliances 360DVSR you will learn all the available features of the product, as well as information on its operation. The information that you get Majestic Appliances 360DVSR will certainly help you make a decision on the purchase.
If you already are a holder of Majestic Appliances 360DVSR, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Majestic Appliances 360DVSR.
However, one of the most important roles played by the user manual is to help in solving problems with Majestic Appliances 360DVSR. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Majestic Appliances 360DVSR along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center