Instruction/ maintenance manual of the product MC2000 M&S Systems
Go to page of 44
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com MC2000 Owner’ s Man ual.
Copyright 2003 by M&S Systems MC2000 and the M&S Digital Networks logo are registered trademarks of M&S Systems. RealOne Player is a registered trademark of RealNetworks, Inc.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page i Table of Contents MC2000 Owner’s Manual...................................................................................... 1 Introduction ....................
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page ii Info Menu ................................................................................................................ 34 Troubleshooting ....................
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 3 Introduction Built around a digital network hub, the MC2000 is a whole-house distributed audio communications system complete with multi- source music, d oor chimes, intercom, paging, and monitoring.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 4 have their favorite rock station blaring in another room. You can even select the music playing in another room to play in the ro om you’re in. You can program the MC2000 to let you go to sleep with music and to wake up with music.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 5 Impor tant Safety Instructions for the MC2000 The MC2000 must be installed by certified M&S Systems dealers or installers, and must conform to all local building and electrical codes.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 6 Unplug the MC2000 from the wall outlet prio r to cleaning. Use only a damp cloth to clean the hub cabinet, room stations, and speakers. Do not wipe the LCD with a damp cloth; use only a soft cloth on the LCD screen.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 7 Getting Star ted: Set up the System We recommend you customize your MC2000 prior to using the system. Customizing the system will make the system easier to use and will allow you to access all system features.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 8 1. Press the More button shown in Figure 3. Figure 3 - Main Menu 2.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 9 The Setup Menu is where you establish the tim e, date, and year settings and customize the system to meet your nee ds for each room with the room station. Figure 5 - Setup Menu Set the Time The Set Time menu allows you to set or change the current system time.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 10 3. After you have the time at the correct se tting, press Set to save the settings or Cancel to discard them. After 30 seconds of inactivity, the room station s creen will return to the Greeting Menu shown in Figure 2.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 11 Name a Roomstation The Name Room menu allows you to customiz e each room station’s system name. To change the room station name, follow the steps shown below. 1.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 12 Room F eatures The Room Features menu allows you to customize each room’s intercom, paging and monitoring settings. These settings must be adjusted at each room station on the MC2000 system.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 13 To select one of these room station configurations press the button shown in Figure 2, each button press will toggle between the pre-configured room settings. After 30 seconds of inactivity, the room station returns to th e Greeting Menu shown in Figure 2.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 14 Door Stations The MC2000 system supports two door statio ns. Once th e doorbells are installed, they will ring on all room stations. Whether the doorbells can be hear d or monitored from an individual room station depends on how it’s been set u p.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 15 2. To change the name of a door station, press the Name Station butto n. The default MC2000 settings are “Front Door ” and “Rear Door”. The Name Station menu looks like the Name a Room menu shown in Figure 8.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 16 Setting up a P assw ord The Password menu allows you to establish a four-digit password for your MC2000 system. This password protects your system setting s and keeps them from being changed.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 17 Figure 14 - Enter Password Screen 7. You are required to confirm the passwo rd by re-entering the same four numbers. A confirmation screen tell s you the pa ssword has been set.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 18 Removing or Changing a Password Follow the steps below to change or remove your MC2000 password. You will n eed to have the current password to complete this step.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 19 5. Enter the new password following the same steps previously described and as shown in Figure 14. 6. Confirm the password by reentering it. You will receive a password confirmation screen.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 20 Note: acoustic decay relates to the fact th at acoustic echoes decay exponentially with time. The settings below allow the ec ho canceller in the room stations to perform better with a known decay rate for a particular room.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 21 Using the MC2000 The Greeting Menu is the default menu for the room station display. Any time a menu is inactive for more than 30 seconds, the d isplay returns to this menu.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 22 • Room Control toggles between Default, Priv acy, Nap, and Custom (see Setup , page 12, for detailed informat.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 23 Main Menu The Main Menu provides easy access to all MC2000 functions: Figure 20 - Main Menu • Music : Select music sources. • Wake : Set the time you want the music to come on.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 24 Music Menu The Music menu contains the options for personalizing and managing your music choices. Figure 21 - Music Menu • FM/AM : Select FM or AM radio frequency bands or preset stations.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 25 After 30 seconds of inactivity, the room station returns to th e Greeting Menu shown in Figure 19.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 26 3. Use the Tune up and down arrows shown in Figure 23 to move incrementally though the radio band. Use the Seek buttons to find the station you want. Select FM (or AM if you are programming an AM station) to store the station in the system memory.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 27 Figure 24 - Tune/Presets Menu - Stored Station If the menu is inactive fo r more than 30 seconds, it returns to the Greeting Menu shown in Figure 19.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 28 4. Select the room name playing the remote device you want to hear as shown in Figure 25. You should hear the media playing from the remote device. You may also select one of the radio stations disp layed.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 29 W ak e Menu The wake feature allows you to program the MC2000 room station to begin playing music at a specific time, much like an ala rm clock, or clock radio. You can store up to five events, or wake ti mes.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 30 • Store : Changes do not occur unless you press the Store button and then press Yes on the Overwrite Wake Event menu. You get a confirmation message for both saving and cancelin g an event.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 31 2. Press the Sleep button to start the audio, eith er the last audio played, or a currently selected audio. Press the button again to increase the time. The increments are 5, 10, 15, 30, 45, 60, 75, and 90 minutes.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 32 After 30 seconds of inactivity, the room station returns to th e Greeting Menu shown in Figure 19. Intercom Menu The Intercom function allows you to establish a private conversation between two room stations on the MC2000 system.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 33 After 30 seconds of inactivity, the room station returns to th e Greeting Menu shown in Figure 19. Monitor Menu The Monitor function allows you to monitor a particular room on the MC2000 system.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 34 Answ ering a Doorbell When either of the doorbells ring, all room stations on the system will s how the message shown in Figure 31. The doorbell ring will interrupt any music playing or intercom calls in progress.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 35 Figure 32 - Info Menu If you are in need of assistance with your MC2000 system please contact our technical support team at th e number shown in Figure 33.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 36 T roubleshooting If you need assistance with your MC 2000 System please co nt act our technical support team at 1-800-366-9422. You can also obtain system information, software upgrades and technical support on our web site: www.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 37 W arranty M&S Systems Limited 2-Year Warranty M&S Systems warrants its products to be fr ee of defects for 2 ye ars. Except for the AirVac Gold power units (See below).
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 38 this warranty covers the AirVac Gold po wer units for 10 years instead of 2. The M&S Systems 10-Year Warranty applies ONLY to the Air Vac Gold power units and to no other M&S Systems, M&S or AirVac products.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 39 Definitions Category 5 (CAT5) : Four twisted pairs of copper wire enclosed in an outer jacket used for telephone, fax, modem and high-s peed digital computer transmissions.
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 40 Inde x Alarm clock ......................................................... 29 Clock ra dio .......................................................... 29 Date ..
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 41 F igure Index Figure 1 - Room Station Layo ut ................................................................................................. ..................
2861 Congressman Lane | Dallas, Texa s 75220 | 800.877.6631 | www.mssystems .com Page 42 115972-1.
An important point after buying a device M&S Systems MC2000 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought M&S Systems MC2000 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data M&S Systems MC2000 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, M&S Systems MC2000 you will learn all the available features of the product, as well as information on its operation. The information that you get M&S Systems MC2000 will certainly help you make a decision on the purchase.
If you already are a holder of M&S Systems MC2000, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime M&S Systems MC2000.
However, one of the most important roles played by the user manual is to help in solving problems with M&S Systems MC2000. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device M&S Systems MC2000 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center