LST Fire Alarm Control Panel (BC06-1EXT)
Table of Contents 9 sections Extinguishing Control Panel · BC06-1EXT, BC06-2EXT · Description · 0786–CPD–20300 · … ShowHide
Page 1 of the LST Fire Alarm Control Panel (BC06-1EXT) user manual — 0786–CPD–20300
Page 1 · click to enlarge
Page 1
LST Fire Alarm Control Panel (BC06-1EXT) — Extinguishing Control Panel diagram (page 1)
Fig. 1 · Extinguishing Control Panel

Extinguishing Control Panel

LST Fire Alarm Control Panel (BC06-1EXT) — Extinguishing Control Panel diagram (page 1)
Fig. 2 · Extinguishing Control Panel
LST Fire Alarm Control Panel (BC06-1EXT) — Extinguishing Control Panel diagram (page 1)
Fig. 3 · Extinguishing Control Panel
LST Fire Alarm Control Panel (BC06-1EXT) — Extinguishing Control Panel diagram (page 1)
Fig. 4 · Extinguishing Control Panel

BC06-1EXT, BC06-2EXT

LST Fire Alarm Control Panel (BC06-1EXT) — BC06-1EXT, BC06-2EXT diagram (page 1)
Fig. 5
LST Fire Alarm Control Panel (BC06-1EXT) — BC06-1EXT, BC06-2EXT diagram (page 1)
Fig. 6
  • For application in single-zone extinguishing systems
LST Fire Alarm Control Panel (BC06-1EXT) — BC06-1EXT, BC06-2EXT diagram (page 1)
Fig. 7
  • 4 detector zones in conventional technology
  • Differentiation between the activation of automatic detectors and manual call points on the same detector line
  • Clear display and operation on the panel front
  • Tested to EN 54-2, -4, EN 12094-1 by VdS

Fire is a permanent threat to life and property. There- fore, immediate response to a fi re is imperative. The main objective of the Fire Detection Control Panel Series BC06 is to alarm and to react in time and, con- sequently, save lives and protect property. For decades LST have focused their aims to undertaking unrivaled efforts in order to realise new innovations in the security area. Research, development and production are loca-

ted within LST premises, thus guaranteeing fl exible and reliable individual solutions.

Using a powerful processor system and a large number of integrated functions, the Fire/Extinguishing Control Panels Series BC06 ensure topmost effi ciency and speed – prerequisites for saving lives and minimising damage to property.

LST Fire Alarm Control Panel (BC06-1EXT) — BC06-1EXT, BC06-2EXT diagram (page 1)
Fig. 8

Description

Already in the basic version the combined Fire/Extingu- ishing Control Panels BC06-1EXT and BC06-2EXT are equipped with four detector lines and the Extinguishing Board EXB1-1 and, owing to its sophisticated factory settings, are immediately ready for operation. This al- lows for quick and effi cient application of the product.

The optional evacuation function serves for the actu- ation of alarming devices independent from activated alarms.

Thanks to the integrated extinguishing module, the BC06 can be used as an extinguishing control panel according to EN 12094-1 with one fl ooding zone. The module provides appropriate inputs and outputs for con- trolling and monitoring a fl ooding zone. The display and operating elements that are necessary for the status indication and the operation of the extinguishing module are integrated into the keypad. A printer for the event log can be connected via the optional Serial Interface Modul SIM06-1.

The conventional technology allows for the connection of automatic and non-automatic fi re detectors as well as a wide range of special detectors with contact out- put. Alarms from manual call points and from automatic detectors that are connected together to one detector line can be differentiated and thus evaluated differently by the fi re/extinguishing control panel, by means of an optional coding module.

The Fire/Extinguishing Control Panel BC06-2EXT dif- fers from the BC06-1EXT by the additionally integrated 4-digit electronic alarm counter.

Thanks to the two auxiliary inputs whose parameters can be freely set as well as the eight open-collector out- puts, manifold tasks in the fi eld of fi re alarm technology can be realised.

0786–CPD–20300

BC06EXT_DBL_LST_EN_0826.PDF • PAGE 1 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Page 2 of the LST Fire Alarm Control Panel (BC06-1EXT) user manual — Clear concept
Page 2 · click to enlarge
Page 2
LST Fire Alarm Control Panel (BC06-1EXT) — Clear concept diagram (page 2)
Fig. 9 · Clear concept

Clear concept

The combined Fire/Extinguishing Control Panels BC06-1EXT and BC06-2EXT have been designed for use in small fi re detection and extinguishing control sys- tems with one fl ooding zone, and already in the basic version they provide the following features:

  • All events that occur can be output in English via a connected printer or PC. Thus, all system conditions and user operations that occurred are documented in a clearly laid out way.
  • The Fire/Extinguishing Control Panel BC06-2EXT includes a 4-digit, non-resettable alarm counter which indicates the total number of alarms by means of an LC display in the operating fi eld.
  • A possible breakdown of the central processing board is securely detected and displayed by the system.
  • The processor-monitored power supply ensures permanent supervision and charging of the batteries. This way, even during a power failure the untroubled and uninterrupted operation (for more than 72 hours depending on the design of the batteries) is guaranteed.
  • Three hierarchised authorization levels for operation and parameterisation provide a high degree of security against unauthorized access.
  • The control panel is easily operated and the parameters are set via the display and operating fi eld. LEDs indicate the current menu and the selected parameter. This facilitates user guidance during commissioning, operation and maintenance.
  • The initial commissioning of the control panel is signifi cantly facilitated by the practical factory settings. This guarantees easy and time-saving commissioning.
  • 4 conventional detector lines permit the connection of automatic detectors and manual call points in conventional technology as well as special detectors with contact output. Each detector line can be individually parameterised as detector zone for fi re alarms, as detector zone for fault messages or as input for a disable device or a fl ooding switch.
  • If automatic detectors and manual call points are connected together on one detector line, their activations can be differentiated and evaluated differently by the control panel. To this aim, the manual call points must be equipped with a special coding module.
  • Two individually monitored, separately actuated siren outputs with an output current of 1A and 0.5A respectively, allow for the connection of acoustic or optical signalling devices.
  • Dry relay outputs indicate the alarm and fault conditions of the control panel. In addition, 8 open-collector outputs whose parameters can be freely set as well as two auxiliary inputs are available for general control tasks.
  • The Extinguishing Board EXB1-1, which is already installed in the control panel, allows for the actuation of an extinguishing system according to EN 12094-1 with one fl ooding zone. In the course of commissioning the control panel, the required functions and delay times are parameterised according to the used extinguishing agent as well as the country specifi c regulations. The extinguishing board provides 8 further open-coll-

The extremely fl at wall-mount cabinet allows for an easy mounting in virtually any place of the building. Thanks to its modern, ageless design, architectural requirements and demands of the respective regulations are ideally combined. Thanks to the compact design, the standard case can accommodate batteries with up to 7Ah also in the event of full extension (central processing board, extinguishing board and an auxiliary module) of the con- trol panel. Series BC06 thus stands for modularity and easy expansion.

ector outputs with fi xed preset functions. • Logical combinations of detector zones for the ac- tivation of external alarming devices and for the ac- tuation of the extinguishing system allow for a high degree of fl exibility. Thus, no additional expenses arise for external relays or logic gates. Thanks to the wide range of parameterisation possibilities, individu- al requirements even under the most diffi cult ambient conditions can be combined into a reasonable fi re protection strategy.

This product complies with all relevant standards of EN 54 and EN 12094-1 and is tested by the VdS. LST‘s high quality level is secured by a permanently monitored quality management system certifi ed to ISO 9001.

BC06EXT_DBL_LST_EN_0826.PDF • PAGE 2 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Page 3 of the LST Fire Alarm Control Panel (BC06-1EXT) user manual — Display and operating elements
Page 3 · click to enlarge
Page 3

Extinguishing control

By means of the Extinguishing Board EXB1-1, the Fire/Extinguishing Control Panels BC06-1EXT and BC06-2EXT provide numerous inputs and outputs with fi xed or parameterisable function. With that, the follo- wing components of an extinguishing system can be ac- tuated and monitored in accordance with EN 12094-1:

  • ents of the extinguishing system
  • A disable device for the indication of the mechanical blocking of the extinguishing agent‘s network
  • A fl ooding switch that indicates the fl ow of the extinguishing agent
  • A device for switching to the manual mode – for example, a key switch
  • Signalling devices for indicating the activated condition and the released condition
  • The control device for activating the fl ooding – for example, a solenoid valve
  • Auxiliary outputs for actuating fl aps or for turning off devices and systems
  • Activation devices for the manual activation of the fl ooding process
  • Emergency hold devices for the manual delay of the fl ooding process
  • Emergency abort devices for aborting the fl ooding process
  • Fault detection devices for monitoring the compon-
LST Fire Alarm Control Panel (BC06-1EXT) — Extinguishing control diagram (page 3)
Fig. 10 · Extinguishing control
LST Fire Alarm Control Panel (BC06-1EXT) — Extinguishing control diagram (page 3)
Fig. 11 · Extinguishing control

Display and operating elements

The operating fi eld of the Fire/Extinguishing Control Pa- nels BC06-1EXT and BC06-2EXT provides 13 LEDs for displaying the operating conditions and 4 buttons for the operation of the extinguishing system.

  • The buttons on the operating fi eld have the following functions:
  • Disable/enable the extinguishing module
  • Start/terminate the manual mode
  • Disable/enable the activation devices
  • Disable/enable the signal output
  • The LEDs indicate the following operating conditions:
  • Pre-activation/activation of the extinguishing module
  • Released condition of the extinguishing output
  • Extinguishing output fault
  • Extinguishing module fault/disablement
  • Extinguishing medium fault/fault of the fault input
  • Emergency hold/emergency hold device fault
  • Activation device fault/disablement
  • Signal output activated/signal output faulty/disabled
  • Manual mode of the extinguishing module
  • Fault of the activated condition output
LST Fire Alarm Control Panel (BC06-1EXT) — Display and operating elements diagram (page 3)
Fig. 12 · Display and operating elements

BC06EXT_DBL_LST_EN_0826.PDF • PAGE 3 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Page 4 of the LST Fire Alarm Control Panel (BC06-1EXT) user manual — Specifi cations
Page 4 · click to enlarge
Page 4
LST Fire Alarm Control Panel (BC06-1EXT) — Functions of EN 12094-1 diagram (page 4)
Fig. 13 · Functions of EN 12094-1

Functions of EN 12094-1

  • All mandatory functions of EN 12094-1 are integrated into the Fire/Extinguishing Control Panels BC06-1EXT and BC06-2EXT. Furthermore, the most important optional functions of this standard are supported:
  • Parameterisable pre-discharge-warning time for the delay of the activation
  • Detector zone „extinguishing medium active“ selectable for detecting the fl ow of the extinguishing medium
  • Monitoring of components of the extinguishing system
  • Input for connection of an emergency hold device
  • Monitoring of a disable device
  • Parameterisable fl ooding time
  • Possibility to switch to the „manual only mode“
  • Transmission of the triggering signal to further actuations within the extinguishing system – for example, warning devices
  • Transmission of the triggering signal to further actuations outside the extinguishing system – for example, for turning off the air conditioning system
  • Emergency abort device can be connected
  • Activation of alarming devices with different alarm signals
LST Fire Alarm Control Panel (BC06-1EXT) — Functions of EN 12094-1 diagram (page 4)
Fig. 14 · Functions of EN 12094-1

Specifi cations

Mains voltage 230VAC +10/-20%, 47...63Hz

Output/nominal voltage typ. 27.6VDC

Output current max. 2.2A

Output current siren outputs output 1 max. 1A output 2 max. 0.5A (the sum of the currents of the signalling devices that are connected to the two outputs must not exceed 1A!)

Output current, extinguishing output max. 1A

Output current, activated condition output/signal output max. 500mA per output

Own current consumption (incl. extinguishing board) at 24V typ. 80mA (without optional componentries, line termination 5.6kΩ) typ. 65mA (without optional componentries, line termination 47µF)

Line voltage typ. 20V (line termination 5.6kΩ) typ. 23V (line termination 47µF)

Line current without fi re detectors typ. 3.7mA (line termination 5.6kΩ) typ. 0mA (line termination 47µF)

Line termination 5.6kΩ or 47µF

Line resistance max. 50Ω per core

Ambient temperature -5°C to +50°C

Relative humidity max. 95% (no condensation)

Dimensions W × H × D 330 × 330 × 90 (mm)

Colour grey-white, RAL 9002

Weight without batteries approx. 3kg

Approvals 0786-CPD-20300 VdS pending

Fire Detection Control Panel BC06-1EXT

Order name Fire Detection Control Panel BC06-1EXT/INT1

Fire Detection Control Panel BC06-2EXT

Order name Fire Detection Control Panel BC06-2EXT/INT1

BC06EXT_DBL_LST_EN_0826.PDF • PAGE 4 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED

Order number 210223 · Order number 210224

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the LST Fire Alarm Control Panel (BC06-1EXT)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the LST Fire Alarm Control Panel (BC06-1EXT)

Be the first to ask — other owners or our team will answer.

Original document

LST Fire Alarm Control Panel (BC06-1EXT) manual PDF

4 pages·318 KB·Home Security System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…