LST Battery Charger (BC016-2)

3 pages·256 KB·Battery Charger·PDF·ENDEFRITNLJA
LST Battery Charger (BC016-2)
Table of Contents 6 sections Fire Detection Control Panel · BC016-2 with Evacuation Functions · Description · Clear Concept · … ShowHide
Page 1 of the LST Battery Charger (BC016-2) user manual — Description
Page 1 · click to enlarge
Page 1
LST Battery Charger (BC016-2) — Fire Detection Control Panel diagram (page 1)
Fig. 1 · Fire Detection Control Panel

Fire Detection Control Panel

LST Battery Charger (BC016-2) — Fire Detection Control Panel diagram (page 1)
Fig. 2 · Fire Detection Control Panel
LST Battery Charger (BC016-2) — Fire Detection Control Panel diagram (page 1)
Fig. 3 · Fire Detection Control Panel
LST Battery Charger (BC016-2) — Fire Detection Control Panel diagram (page 1)
Fig. 4 · Fire Detection Control Panel

BC016-2 with Evacuation Functions

  • For small and mid–sized systems
LST Battery Charger (BC016-2) — BC016-2 with Evacuation Functions diagram (page 1)
Fig. 5 · BC016-2 with Evacuation Functions
  • Addressable conventional technology with a maximum of 16 zones
  • Up to 8 evacuation circuits
  • Menu-driven operation
  • Free parameter setup via PC software or operating fi eld
  • Factory settings allow for easy commissioning
  • EN 54/VdS-certifi ed

Fire is a permanent threat to life and property. There- fore, immediate response to a fi re is imperative. The main objective of the fi re detection control panel Series BC016 is to alarm and to react in time and, conse- quently, save lives and protect property. For decades LST have focused their aims to undertaking unrivaled efforts in order to realize new innovations in the security area. Research, development and production are loca-

ted within LST premises, thus guaranteeing fl exible and reliable individual solutions.

Using a powerful processor system, display texts, and a large number of integrated functions, the fi re detection control panels Series BC016 ensure topmost effi ciency and speed – prerequisites for saving lives and minimi- zing damage to property.

LST Battery Charger (BC016-2) — BC016-2 with Evacuation Functions diagram (page 1)
Fig. 6 · BC016-2 with Evacuation Functions

Description

Fire detection control panel BC016-2 in design and function corresponds to fi re detection control panel BC016-1. In addition, the BC016-2 has the possibility to operate up to eight alarming devices as evacuation circuits directly via the expanded keypad of the control panel. These evacuation circuits can be actuated either dependent of the alarm situation of the detector zone or by a superordinate danger detection device.

can manually start or terminate an evacuation alarm on the fi re detection control panel without prior alarm of a fi re detector. In the LED fi eld, the fi rst zone displays are automatically used for displaying the operating conditi- ons of the evacuation circuits.

For security reasons a two-button operation must be performed to activate an evacuation circuit.

Using the expanded keypad, you can manually activate or deactivate the alarming devices that have been para- meterised as evacuation circuits independent from the alarm situation on the control panel. This way, the user

The physical outputs for the control and monitoring of the alarming devices are provided by optional modules (e.g., siren connection module SZ58-3).

BC016-2_DBL_LST_EN_0804.PDF • PAGE 1 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Page 2 of the LST Battery Charger (BC016-2) user manual — Clear Concept
Page 2 · click to enlarge
Page 2
LST Battery Charger (BC016-2) — Clear Concept diagram (page 2)
Fig. 7 · Clear Concept

Clear Concept

The fi re detection control panel BC016-2 has been desi- gned for use in small and mid-sized systems and alrea- dy in its basic version provides the following features:

  • A possible breakdown of the central processing board is securely detected and displayed by the system.
  • The processor-monitored power supply ensures permanent surveillance and charging of the batteries. This way, even during a power failure the untroubled and uninterrupted operation (for more than 72 hours depending on the design) is guaranteed.
  • Three hierarchized authorization levels for operation and parameterisation facilitate a high degree of security against unauthorized access.
  • The control panel is easily operated menu-driven via the display and operating fi eld. Clear instructions on the display guide the user during commissioning, operation and maintenance.
  • The parameter data can be entered either via the display and operating fi eld or, in a more comfortable way, created by means of the PC software PARSOFT-1 and loaded into the control panel. Thus, a quick and effi cient transfer of the system confi guration into the control panel is guaranteed.
  • After activation, the control panel is immediately ready for operation due to the practical factory setting. This guarantees easy and time-saving commissioning.
  • 8 conventional detector lines permit the connection of automatic detectors and manual call points in conventional technology as well as special detectors with contact output. Individual detector identifi cation can be achieved by means of an optional address module.
  • A slot for connecting the Detector Zone Extension MGE8-1 is available for the extension to 16 conventional detector lines.
  • Dry relay outputs indicate the alarm and fault conditions on the control panel. In addition, 16 open-collector outputs, two auxiliary inputs, and an additional relay output are available for general applications.
  • Up to 8 alarming devices can be operated as evacuation circuits directly via the expanded keypad of the fi re detection control panel.
  • The optional Fire Brigade Interface FWI016-1 allows for the connection of two independent transmitting devices for a direct interconnection to a designated alarm respondent (e.g., the fi re brigade) as well as for the connection of a country-specifi c fi re brigade control unit.
  • Outputs with open parameters and logical combinations of detector zones for the activation of external controls and alarming devices allow for a maximum of fl exibility. Thus, no additional expenses arise for external relays, logic gates or timers. Using these individual combinations of different types of detectors, even fi re protection strategies under the most diffi cult circumstances can be combined into a reasonable concept.
  • The LC text display shows all present events with date and time. This allows for quick and targeted reaction in the event of a fi re as well as for easy maintenance.
  • An event memory allows for the display of the latest 200 events at any time, including all required information. Thus, all system conditions and user operations that occurred are documented in a clearly laid out way.

The extremely fl at wall mount cabinet allows for an easy mounting in virtually any place of the building. Thanks to its modern, ageless design, architectural requirements and demands of the respective regulations are ideally combined. The compact design allows for the accom- modation of the optional Detector Zone Extension, the Fire Brigade Interface, the Serial Interface Module, up to 3 auxiliary modules (e.g., relay module, siren connec- tion module) and batteries up to 22Ah apart from the central processing board in the standard case. Series BC016 thus stands for modularity and easy expansion.

This product complies with all relevant standards of EN 54 and is VdS-certifi ed. In addition, the product also holds several country-specifi c approvals and certifi ca- tes. LST‘s high quality level is secured by a permanent- ly monitored quality management system certifi ed by ISO 9001.

BC016-2_DBL_LST_EN_0804.PDF • PAGE 2 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Page 3 of the LST Battery Charger (BC016-2) user manual — Specifi cations
Page 3 · click to enlarge
Page 3
LST Battery Charger (BC016-2) — Permanent Connection diagram (page 3)
Fig. 8 · Permanent Connection

Permanent Connection

A variety of peripheral devices can be connected to the

fi re detection control panel BC016-2:

  • Fire brigade key safe
  • Fire brigade control unit
  • Acoustic and optical signaling devices
  • External protocol printer
  • Remote indication unit
  • Actuations
  • Modules for remote parameterisation and remote maintenance via computer newtork, modem or GSM connection – and much more.
LST Battery Charger (BC016-2) — Permanent Connection diagram (page 3)
Fig. 9 · Permanent Connection
LST Battery Charger (BC016-2) — Permanent Connection diagram (page 3)
Fig. 10 · Permanent Connection

Specifi cations

Mains voltage 230VAC +10/-15%, 50Hz

Output/nominal voltage typ. 28VDC

Output peak current max. 1.8A

Own current consumption at 24V typ. 70mA (without optional componentries)

Ambient temperature -5°C to +50°C

Relative humidity 95% (no condensation)

Dimensions W × H × D 380 × 480 × 83 (mm)

Colour gray-white, RAL 9002

Weight without accumulator approx. 5kg

Approvals (EN 54-2, EN 54-4) VdS G205023 FT 14/439/04 (Austria),

Part No. 210122

Order name Fire and Evacuation Panel BC016-2/INT1

BC016-2_DBL_LST_EN_0804.PDF • PAGE 3 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the LST Battery Charger (BC016-2)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the LST Battery Charger (BC016-2)

Be the first to ask — other owners or our team will answer.

Original document

LST Battery Charger (BC016-2) manual PDF

3 pages·256 KB·Battery Charger·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…