EN
Official user manual

Lowel Light 4

4 pages·394 KB·Indoor Furnishings·PDF·ENDEFRITNLJA
Lowel Light 4
Table of Contents 18 sections Lowel Caselite ® Instructions · General Warnings Contents · LOWEL CASELITE4 · & LOWEL CASELITE2 · … ShowHide
Page 1 of the Lowel Light 4 user manual — LOWEL CASELITE4
Page 1 · click to enlarge
Page 1

Lowel Caselite ® Instructions

General Warnings Contents

The Lowel Caselite is a profes- sional lighting system. Read these instructions and lamp man- ufacturers’ warnings before oper- ating.

Fluorescent Warnings n Avoid looking directly at the tubes

Opening the Unit 2 Stand Mounting 2 Tilting & Pointing 2 Controlling Light Intensity 3 Fuse Change 3 Lamps & Lamp Changes 3 Light Controls 4 Barndoor/Intensifiers 4 Egg Crates 4 Gel Clips 4 Closing/Transporting 4 Problems, Repairs & 4

for extended periods of time. n Fluorescent tubes contain highly

poisonous mercury. n In the event of lamp breakage,

n Do not leave Caselite unattended.

avoid contact with broken pieces. n Read lamp manufacturers

For non-stationary (portable location) use. n Not for household use. Use only

information fully.

for photo graphic lighting (video & film imaging). n Do not exceed maximum rated

wattage for unit. n Use maximum 55 Watt lamps. n Always unplug unit before relamping. n Be sure lamp is securely seated

Lowel Light 4 — General Warnings Contents diagram (page 1)
Fig. 1 · General Warnings Contents

in lamp socket. n Do not use near standing water. n Internal ballast produces high

LOWEL CASELITE4

& LOWEL CASELITE2

start-up voltage. n Never bypass plug’s ground pin. n Do not interfere with unit’s

ventilation. n When attaching to overhead pipes

or grids, always use a Safety Cable. n Do not attempt to open unit,

no user serviceable parts inside. See p. 3 for fuse change. n This is a portable location light.

It complies with UL 1573 for still photographic lights when used with the supplied T1-80 cable. For use as a portable stage lighting unit use with Lowel T1-808 10’ unswitched cable rated for ‘hard service’.

Caselite 2 Uses 2 lamps

Lowel Light 4 — LOWEL CASELITE4 diagram (page 1)
Fig. 2

Caselite 4 Uses 4 lamps

Page 2 of the Lowel Light 4 user manual — E
Page 2 · click to enlarge
Page 2

Caselite ® Operations

Opening the Unit Stand Mounting Tilting & Pointing

Laying the Caselite down, with its rear mounting adaptor facing up, release the twist-locks and lift the fixture half straight up off the lid half. Lay the fixture down with its exterior facing up. Release the interior flap locking straps on the lid to allow opening of the storage compartment. Remove the Mounting Plate, Stand-fitting Tilt-brack- et (& Uni Sr. Stand, if stored in lid).

With the Caselite fixture face down, attach the mounting plate C to the adaptor receptacle in the center of the fixture, as shown. Turn the 4 twist-lock knobs D to lock the plate firmly to the fixture. Mount Stand-fitting Tilt-bracket A onto stand (5/8” stud) and tighten knob E. Loosen large locking knob B on Mounting Plate, lift Caselite and insert stud end of stand fitting bracket A into Mounting Plate fitting. Note that the Tilt-bracket stud has a safety indent cut into it. Make sure to line up the Mounting Plate knob so that its screw will tighten into the indent, for most secure mounting. Tighten B sufficiently. If you are attaching Caselite Mounting Plate to a grip arm or boom, be sure to tighten sufficiently and use a larger stand with counter balance weight to retain stability.

The Stand-fitting Tilt-bracket is designed to place the fixture’s center of gravity squarely over the center of the stand, while allowing a complete range of rotation and tilting. With the fixture mounting plate tightly mounted to the Tilt-bracket, loosen the large locking knob slightly to tilt the light on one axis (up & down) and the smaller locking knob to rotate the light on the other axis (vertical vs horizontal placement). Tighten both locking

Lowel Light 4 — Opening the Unit Stand Mounting Tilting & Pointing diagram (page 2)
Fig. 3 · Opening the Unit Stand Mounting Tilting & Pointing

knobs to secure fixture position.

Caselite 2

Caselite 4

A

B

D

Lowel Light 4 — Caselite 2 diagram (page 2)
Fig. 4 · Caselite 2

E

Page 3 of the Lowel Light 4 user manual — Osram Studioline ®
Page 3 · click to enlarge
Page 3

Caselite ® Operations

Controlling Light Intensity

Fuse Change

Light intensity is controlled through the individual lamp switches. In each Caselite, the first tube is controlled by the AC switch in the power cable and remaining lamps are controlled by the switch(es) on back of fixture.

Caselite 2 Switch

The Caselites come with a user-replace- able mini fuse which is installed in a small holder on the same plate as the exterior AC power socket. Access the fuse by removing the cap with a small flathead screwdriver. Swap fuse if necessary and replace holder.

Lowel Light 4 — Caselite 2 Switch diagram (page 3)
Fig. 5 · Caselite 2 Switch

A To turn the fixture on, Click the

power switch on the AC cable. This will turn lamp 1 on.

Caselite2 ETL model uses fuses rated at 3.15 Amps and 250 Volts.

Caselite 4 Switches

B Operate the switches on the back

of the unit to turn the other lamp(s) on. By using these switches, you will be able to control light intensity level.

Lowel Light 4 — Caselite 4 Switches diagram (page 3)
Fig. 6 · Caselite 4 Switches

Caselite4 ETL model uses fuses rated at 5 Amps and 250 Volts.

Fuse

Lowel Light 4 — Fuse diagram (page 3)
Fig. 7 · Fuse

Lamps & Lamp Changes

Lamps The Caselites use compact (55 watt) fluorescent lamps.

Lamp Changes To change a lamp, remove the plastic eggcrate (if attached) by releasing the snap-locks on each end. Remove both metal endplates by turning the twist- locks (see illus.). Note that the light- tube sockets are installed on alternating ends of the fixture. To remove a tube, gently grasp it by its glass end and swing it slightly out from the fixture while pulling it carefully from the sock- et. Replace lamp in same way, opposite order. (Be very careful as lamp-tubes are fragile and can easily shatter. Read

Voltage Selector The Caselite has an auto voltage setting ballast. The Caselite will set itself automatically from 120 - 240v.

GE Cinema-Plus ® Lamps (Manufacturer rated lamp life 8,000 hrs)

Better lighting for film (still or motion picture) due to better color rendering with film emulsions. May require “minus green” filtration gel (1/8).

FLC55-TU Cine-Plus 55w/ 90+ 3200

FLC55-DA Cinema-Plus 55w 90+ 5500

Lowel Light 4 — GE Cinema-Plus ® Lamps (Manufacturer rated lamp life 8,000 hrs) diagram (page 3)
Fig. 8 · GE Cinema-Plus ® Lamps (Manufacturer rated lamp life…
Lowel Light 4 — GE Cinema-Plus ® Lamps (Manufacturer rated lamp life 8,000 hrs) diagram (page 3)
Fig. 9 · GE Cinema-Plus ® Lamps (Manufacturer rated lamp life…
Lowel Light 4 — GE Cinema-Plus ® Lamps (Manufacturer rated lamp life 8,000 hrs) diagram (page 3)
Fig. 10 · GE Cinema-Plus ® Lamps (Manufacturer rated lamp life…
Lowel Light 4 — GE Cinema-Plus ® Lamps (Manufacturer rated lamp life 8,000 hrs) diagram (page 3)
Fig. 11 · GE Cinema-Plus ® Lamps (Manufacturer rated lamp life…

Osram Studioline ®

Lowel Light 4 — Osram Studioline ® diagram (page 3)
Fig. 12 · Osram Studioline ®
Lowel Light 4 — Osram Studioline ® diagram (page 3)
Fig. 13 · Osram Studioline ®

Lamps (Manufacturer rated lamp life 8,000 hrs) Designed for use in video & digital imaging for higher output.

Lowel Light 4 — Osram Studioline ® diagram (page 3)
Fig. 14 · Osram Studioline ®
Lowel Light 4 — Osram Studioline ® diagram (page 3)
Fig. 15 · Osram Studioline ®
Lowel Light 4 — Osram Studioline ® diagram (page 3)
Fig. 16 · Osram Studioline ®
Lowel Light 4 — Osram Studioline ® diagram (page 3)
Fig. 17 · Osram Studioline ®
Lowel Light 4 — Osram Studioline ® diagram (page 3)
Fig. 18 · Osram Studioline ®
Lowel Light 4 — Osram Studioline ® diagram (page 3)
Fig. 19 · Osram Studioline ®
Lowel Light 4 — Osram Studioline ® diagram (page 3)
Fig. 20 · Osram Studioline ®
Lowel Light 4 — Osram Studioline ® diagram (page 3)
Fig. 21 · Osram Studioline ®
Lowel Light 4 — Osram Studioline ® diagram (page 3)
Fig. 22 · Osram Studioline ®

FLS-55TU Studioline 55w/3200 85 3200

FLS-55DA Studioline 55w/5600 85 5600

Show 5 more labels / short text on this page
Tungsten CRI °K · Daylight CRI °K · lamp mfr's · Tungsten CRI °K · Daylight CRI °K
Page 4 of the Lowel Light 4 user manual — Problems, Repairs &
Page 4 · click to enlarge
Page 4

Lowel Caselite ® Instructions

Light Controls Closing/Transporting

Barndoor/Intensifiers The dual purpose Barndoor/Intensifiers add versatility & output to the Caselite. With the mirror-finish Intensifier side facing in towards the lamps, output can be increased by approximately 40% depending on door positioning. The black Barndoor side can be useful in trimming the spill & output of the fixture.

Gel Clips Gel Clips are installed on each end of the fixture to hold gel pieces cut to the size of the lamp area. Use enclosed Lowel Gel-jaws clips when attaching a larger piece of diffusion material to the outside edges of the Barndoor/ Intensifiers to further soften the light. Note: by doing this you are creating a larger, and therefore softer, light-source.

Replace eggcrate, if used, on the lid flap and snap its locks into the retaining holes. Fold Barndoor/Intensifiers in towards lamps. Loosen stand fitting at stand and remove unit & bracket from stand, laying fixture face down on a table/floor. Loosen large locking knob and remove the stud end of the Stand-fitting Tilt-bracket. Turn the 4 twist-lock knobs to unlock the Mounting Plate from the fixture and remove it. Place both Mounting Plate, Stand-fitting Tilt-bracket inside lid com- partment, taking care that it will fully close. (If using kit version, place Uni Sr. Stand in lid also), See illus. below for most efficient packing order. Secure storage lid flap with locking straps. Laying the lid on its back, replace fixture on top and close the twist-lock brackets, turning them to securely lock the Caselite closed. If transporting the unit in rainy weather, use the optional rain cover to prevent leakage.

To reverse the doors, open them fully & loosen the twist-locks on the black side. Slide the barndoor/intensifier straight out to remove. Flip the door & reinstall, turning the twist-locks to retighten.

Lowel Light 4 — Light Controls Closing/Transporting diagram (page 4)
Fig. 23 · Light Controls Closing/Transporting

Problems, Repairs &

Repairs, problems, suggestions and requests for brochures/ catalogs, instructions and parts lists can be handled through your Authorized Lowel ealer/Distributor or directly through Lowel. Electrical repairs should be made only by Lowel or by a qualified electrician. Caselites are designed and manufac- tured by Fluo-Tec, Mexico in collabora- tion with Lowel-Light Mfg., Inc.

Lowel Light 4 — Problems, Repairs & diagram (page 4)
Fig. 24 · Problems, Repairs &
Lowel Light 4 — Problems, Repairs & diagram (page 4)
Fig. 25 · Problems, Repairs &
Lowel Light 4 — Problems, Repairs & diagram (page 4)
Fig. 26 · Problems, Repairs &
Lowel Light 4 — Problems, Repairs & diagram (page 4)
Fig. 27 · Problems, Repairs &

Egg Crates Caselite comes with a detachable plastic egg crate attached to the inside flap of the storage lid. It can be very useful in controlling spill of the light, with some loss of output. To remove, flip the release levers on each end of the egg crate and carefully remove. Snap egg crate onto fixture in front of lamps.

Lowel Light 4 — Problems, Repairs & diagram (page 4)
Fig. 28 · Problems, Repairs &
Lowel Light 4 — Problems, Repairs & diagram (page 4)
Fig. 29 · Problems, Repairs &
Lowel Light 4 — Problems, Repairs & diagram (page 4)
Fig. 30 · Problems, Repairs &
Lowel Light 4 — Problems, Repairs & diagram (page 4)
Fig. 31 · Problems, Repairs &
Lowel Light 4 — Problems, Repairs & diagram (page 4)
Fig. 32 · Problems, Repairs &
Lowel Light 4 — Problems, Repairs & diagram (page 4)
Fig. 33 · Problems, Repairs &
Lowel Light 4 — Problems, Repairs & diagram (page 4)
Fig. 34 · Problems, Repairs &
Lowel Light 4 — Problems, Repairs & diagram (page 4)
Fig. 35 · Problems, Repairs &

ver 2.3 © 2009, Lowel-Light Mfg., Inc.

Lowel-Light Manufacturing, Inc.

Lowel Light 4 — Problems, Repairs & diagram (page 4)
Fig. 36 · Problems, Repairs &

90 Oser Avenue, Hauppauge, N.Y. 11788 Call: 800 645 2522 or 631-273 2500 e-mail info@lowel.com www.lowel.com

Ask about the Lowel Light 4

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Lowel Light 4

Be the first to ask — other owners or our team will answer.

Original document

Lowel Light 4 manual PDF

4 pages·394 KB·Indoor Furnishings·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…