CU 6005/6010/6011 Central Unit Central Unit for series DCS 6000 Voting Units, Conference Units, Interpreter Units, Ambient Noise Microphone, Channels Selectors and Audio Output Units

Copyright © 2007 DIS CU6005 6010 6011 REV V.DOC 16-07-2007
No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher.



Microphone conference system with 3+1 ch. interpretation & IR, CU 6005 32
Appendix 36
Technical appendix 36
Microphone conference system with 15+1 ch. interpretation & IR, CU 6010 32
Cabling 36
Accessories (not supplied) 37
Various configurations with RP 6004 Repeater and PS 6000 Power Supply 33
Technical specifications 38
Small system with SW 6000 Conference Management Software 34
Large system with SW 6000 Conference Management Software 35
Copyright © 2007 DIS CU6005 6010 6011 REV V.DOC 16-07-2007
No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher.

The equipment must be connected to earth
The equipment has been tested and found to comply with the limits of the following standards for digital devices:
Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus.
Lightning Flash Symbol, with "The Lightning Flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product enclosure that may be of sufficient magnitude to constitute a risk of shock to persons"
The device complies with part 15 of the FCC rules. Operation is subject to the following conditions: (1) The device may not cause harmful interference, and (2) the device must accept any interference received, including interference that may cause undesired operation.

These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in residential, commercial or light industrial environments. The equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the user manual it may cause harmful interference to radio communications.

Exclamation Point Symbol, with "The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product"
You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.
Installation precautions
Check that the voltage of your local power supply is within the operating voltage of the unit (100-240V AC). If a voltage conversion is required, consult your DIS dealer or qualified personnel.
Allow adequate air circulation to prevent internal heat built-up. Do not place the unit on a surface (rugs, blankets, etc.) that may block the ventilation holes.
Should any liquid or solid object fall into the cabinet, unplug the unit and have it checked by qualified personnel before operating it further.
Do not install the unit in a location near heat sources such as radiators or air ducts, or in a place exposed to direct sunlight, excessive dust or humidity, mechanical vibration or shock.
Set the Power switch to OFF if it is not used for several days.

To avoid moisture condensations do not install the unit where the temperature may rise rapidly.
When installing the unit inside a 19” rack, observe that the rack is properly ventilated. The maximum allowed temperature inside the rack is 40 °C.
The unit is minimum covered by 12 months warranty against defects in materials or work- manship.
To keep the cabinet in its original condition, periodically clean it with a soft cloth. Stubborn stains may be removed with a cloth lightly dampened with a mild detergent solution. Never use organic solvents such as thinners or abrasive cleaners since these will damage the cabinet.
Save the original shipping cardboard box and packing material; they will become handy if you ever have to ship the unit. For maximum protection, re-pack the unit as originally packed from the factory.

The DCS 6000 system has the following main features:
RS232/RS422 connection on CU 6005/6010/6011 for external operation of the system of a PC or control system such as AMX or Crestron
The SW 6000 is an optional software package, which expands the functionality of the DCS 6000 system. The software runs on standard computer technology (Standard PC with Windows 2000 or XP).
Main features of the SW 6000 are:

Conference equipment and channel selectors
The CU 6005/6010/6011 Central Unit supports all available units in the DCS 6000 series:
CS 6032F V/H Channel Selector (flush mounted) DC 6990P Conference Unit (portable) with touch screen DM 6010P Conference Unit (portable) DM 6060P Conference Unit (portable) with one built-in channel selector CM/DM 6070P Conference Unit (portable) with two built-in channel selectors CM/DM 6090P Conference Unit (portable) with two built-in channel selectors and XLR microphone connector CM/DM 6060F Conference Unit (flush mounted)
Central equipment etc.
EX 6010 Extension Unit PS 6000 Power Supply AO 6004 Audio Output box AO 6008 Audio Output box RP 6004 Repeater for four chains JB 6002 Junction Box with 2 outputs JB 6004 Junction Box with 4 outputs
with one built-in channel selectors CM/DM 6510F Conference Unit (flush mounted) with Chip-card and 3 voting buttons CM/DM 6560F Conference Unit (flush mounted) with one built-in channel selector, Chip-card and 3 voting buttons MU 6040C/D Microphone Unit for use with customised front plate with Loudspeaker, Microphone and Buttons. Available in Delegate (D) and Chairman (C) version MU 6042D Dual Microphone Unit for use with FD/FC front plate with Loudspeaker, Microphone and two delegate Buttons AM 6040 Ambient Noise Microphone
IS 6132P Interpreter Set LS 6132P Interpreter Loudspeaker
DV 6501F Voting Unit
Interpreter equipment

The CU 6010 Central Unit for the DCS 6000 is the heart of the system. One CU 6010 is needed in each DCS 6000 system. The CU 6010 consist of four main parts:
The CU 6010 Central Unit has as standard basic functionality.
The design with built in power supply makes the unit suitable for running a small system alone or to be the Central Controller for a large system.
The main features of the CU 6010 Central Unit are:
This manual describes all features available

Front plate layout The front plate layout of the CU 6010 Central Unit consists of a large illuminated LCD display and 8 buttons for setting up/controlling the system:


Details of display
Front plate controls The CU 6010 Central unit features the following controls and display:
The Fault LED will always light up some seconds after the unit is switched on caused by the delayed switching on of the four supplies.
As a warning the light is flashing at an internal temperature above 45°C. At a temperature above 55°C or if one of the DCS-LAN outputs is supplying no voltage, the LED is lighting constantly.
Power switch Switches power on to the whole system. When power is switched ON at the CU 6010 any connected EX 6010 Extension Units will automatically be powered up. An indication in the switch is lighting, when power is switched ON
Please note that the maximum ambient temperature for the CU 6010 is 40 deg. Celsius.
Fault LED This indication lights up, if the internal power supply is malfunctioning i.e. because of overheating or overload of a chain.
LCD Display This display is used for information purposes and set-up purposes.

Buttons The buttons below and to the left of the display are used when stepping through the different menus and for setting up the system:
‘-‘ The dash symbol (‘-‘) preceding a line of text identifies a submenu or a changeable parameter. The submenu or parameter can be selected by pressing the corresponding select button.
‘>’ The ‘>’ symbol preceding a line of text identifies a selected parameter. The parameter can be changed by pressing the up and down buttons. The ‘>’ symbol is shown as long as the value of the parameter currently used is the same as the value shown in the display.
‘*’ The star symbol ‘*’ preceding a line of text identifies a selected parameter, where the value has been changed, but not yet confirmed. The changed value can be confirmed by pressing the Enter button, or it can be dismissed by pressing the Menu button.
‘▲▼’ The up and down symbols shown in the right side of the display (up is shown in the first line and down is shown in the last line) indicates that the current menu consists of more than 4 menu items. It is therefore necessary to use the up and down buttons to scroll through menu items.
Cursor The cursor is used on the LCD display to indicate, when a value is being changed. For a parameter that is subject to a change, the cursor is placed at the value of the parameter, indicating that it is about to be changed.
Symbols The following symbols are used on the LCD display:


Interpreter sets for those languages have to be connected to Chain B1 or B2.
Mains Power connector Connection for mains power. See specs.
Chain B1 & B2 RJ45 connector, 2 pieces
Analog Audio Line input XLR Input connector.
DCS-LAN connectors for connection to DM/CM 6xxx, IS 6032, IS 6132, CS 6032, EX 6010, AO 6004/6008 etc. For connecting Interpreter Sets for up to 16 languages. If more languages are required, Interpreter sets for those languages have to be connected to Chain A1 or A2.
For connection of external Line input signal i.e. the Floor (Speaker) signal from another Conference Microphone System or audio mixers. See specs.
Analog Audio Line output. XLR Output connector.
Power LED’s Those LED’s light up when Power is available on the connector next to the LED and only if the voltage is over 24V (not overloaded).
This connector carries the “Floor” signal. It is used either for recording purposes or for feeding signal to an external loudspeaker system. See specs.
Serial Data Communication RS232 D-Sub9 connector
Control of the system settings is done through selections made in the main menu. Pressing the Menu button will show the Main menu, which comprises the following entries:
RS232 Serial connection for communication to PC etc. Either the RS232 or the RS422 can be used.
Serial Data Communication RS422 D-Sub 9 connector
RS422 Serial connection for communication to PC etc. Either the RS232 or the RS422 can be used.
Chain A1 & A2 RJ45 connector, 2 pieces
DCS-LAN connectors for connection to DM/CM 6xxx, IS 6032, IS 6132, CS 6032, EX 6010, AO 6004/6008 etc. For connecting Interpreter Sets for up to 16 languages. If more languages are required,

A selection is made in the Main menu by scrolling through the menu items with the Up/Down buttons, and pressing the Select button associated with the desired menu item. When scrolling through the menu items, the Main menu wraps around the list of menu items, i.e. passing the last menu item makes the first menu item appear, and likewise when passing the first menu item.
The Audio Control menu comprises the following complete list of adjustment items:
Loudspk volume This is the Master Loudspeaker volume, the audio level of the loudspeakers of the delegate microphone units.
Pressing the Menu and Enter buttons does not have any effect in the Main Menu.
LineOut volume The audio volume of the ‘LINE OUTPUT’ signal from the CU.
Audio control By pressing the select button for the “Audio Control” menu adjustment of the audio levels becomes possible:
Mic->Loudspk Attenuation/Gain of the audio signal transmitted from speaking delegate microphones to the delegate microphone unit loudspeakers.
Mic->LineOut Attenuation/Gain of the audio signal transmitted from speaking delegate microphones to the ‘LINE OUTPUT’ signal.
LineIn->Loudspk Attenuation/Gain of the audio signal transmitted from the ‘LINE INPUT’ to the loudspeakers of the delegate microphone units.
The up/down buttons can now alter the value of the loudspeaker volume. A change made to the loudspeaker volume takes effect immediately. The volume is changed in steps of 1 dB. The value of 0 indicates ‘standard’ setting.
LineIn->LineOut Attenuation/Gain of the audio signal transmitted from the ‘LINE INPUT’ to the ‘LINE OUTPUT’.
Pressing the Menu or the Enter button ends change of loudspeaker volume. Change of other audio levels is done the same way as for the loudspeaker volume in steps of 1 dB. All changes take effect immediately.
LineInlevel Adj Attenuation/Gain of the XLR audio input signal from the ‘LINE INPUT’.

Delegate setup The “Delegate setup” menu comprises the following entries:
This is indicated by a red light in the ‘Speak’ lamp in the microphone unit. Pressing the microphone ON/OFF button again will turn the microphone off
Max Speakers This menu point has two settings:
A Chairman Unit is always in Auto or VOX mode.
The number of ‘Total Speakers’ defines the maximum number of conference units, which can speak at the same time. This includes both delegate and chairman units.
The microphone can only be switched on from a PC running SW 6000 software or from a control system like AMX or Crestron. This will be indicated by red light in the ‘Speak’ lamp in the microphone unit. At this point the delegate can switch off the microphone by pressing the ON/OFF microphone button.
The number of ‘Delegate Speakers’ defines the maximum number of Delegate conference units, which are allowed to speak at the same time is defined as “Max Speakers”.
Please observe that a Chairman Unit can always be switched ON as long as the number set in ‘Max. Total Speakers’ are not exceeded.
Although it is possible to switch to this mode in a stand-alone-system, this mode is only used with an attached PC running SW 6000 software or using with a control system.
Max Requests “Max Requests” defines how many delegate units that can be inserted into the list of delegates requesting to speak at the same time.
Operation Mode This menu point has two settings:
When the max. number is reached, the next delegate pressing the ON/OFF button will be put in the top of the request queue. This is indicated by the green ‘Request’ lamp flashing slowly.

More delegates will be put in the request queue when they press their ON/OFF buttons, until the maximum of requests is reached. Their green ‘Request’ lamps will light up steadily.
but 3 flashes in the green LED will indicate, that the maximum number has been reached.
It is similar for Chairman units if the number of open units (Chairman and Delegate) has reached the number specified in the setting “Max. Total Speakers”.
When one of the turned ON microphone units is switched off, the first delegate unit in the queue is automatically switched ON, and the next delegate unit in the queue will flash with the green ‘Request’ lamp.
Lower If however “Lower” is selected a chairman will interrupt (switch Off) the first switched On delegate unit if the number of open units (Chairman and Delegate) has reached the number specified in the setting “Max. Total Speakers”.
This mode will normally be used with only 1 as maximum speakers.
Lower+Same If “Lower+Same” is selected a delegate unit will interrupt (switch Off) the first switched On delegate unit if the number of delegate units has reached the number specified in the setting “Max. Delegate Speakers”.
This is indicated by a red light in the ‘Speak’ lamp in the microphone unit. Pressing the microphone ON/OFF button again will turn the microphone off.
Similar a chairman will interrupt (switch Off) the first switched ON delegate unit if the number of open units (Chairman and Delegate) has reached the number specified in the setting “Max. Total Speakers”, and if no delegate unit is switched ON the first switched ON Chairman unit will be switched OFF.
The microphone turns of automatically after finished talking after the time defined in the “Release Time” setting (se later paragraph), which normally is 4 seconds. The microphone can also be turned off by pressing the ON/OFF button.
Voice Detection This menu point has two settings:
A Chairman Unit is always in Auto or VOX mode
Those settings determines the behaviour of the system when working in VOX mode
None When “None” is selected and the number of open Delegate units has reached the number specified in the setting “Max. Delegate Speakers” no more delegate microphone can be opened. Pressing the microphone buttons will not turn on the microphone
The default value is ‘0’. Setting to a lower value makes the microphone more sensitive.

This setting is used to set the time from the delegate stops talking until the microphone turns off. The default value is 4 sec.
When set to 0 value no interpretation channels are present in the system. Only ‘Floor’ sound will be present
Channel 0 will always give the original audio (floor).
Auto Off Setup This menu point has two settings:
Language setup The “Language setup” menu will show the number of channels according to the ‘Interpreter Channels’ settings. :
Those settings determine the behaviour of the Auto Off facility for the conference units.
When set to On a conference unit will automatic turn of the microphone when the delegate stops talking. The time is determined by the ‘Auto Off time’ setting.
A channel entry is selected with the select keys 1-4 and the language for that channel can be chosen with the up/down buttons. If the value is changed is indicated with “>” to the left of the entry.
The new language selection is accepted with Enter button and cancelled with Menu button.
This setting is used to set the time from the delegate stops talking until the microphone turns off. The default value is 5 sec.
Booth Setup The “Booth Setup” menu will show a list op Booth (1 to 128).
When the system is set to VOX mode Auto Off settings are disabled.
The Interpretation Channels can now be assigned to the Booth. More Booths can be assigned the same channel.
Interpretation setup The “Interpretation setup” comprises the following entries:
As default Booth 1 is assigned Channel 1, Booth 2 assigned Channel 2 etc.
Auto Floor When set to ON a language channel with no interpretation will have the Floor sound.
Interpreter Channels This setting is used to set the number of Interpreter Channels in use.
Interpreter Lock The Interlock settings are used to setup the interlock between the Interpretation channels.
The settings are:

Transmission of ambient noise rather than transmitting no sound at all is a desirable feature from listeners attending the meeting via headphones. The ambient noise indicates to the listeners, that there is no speaking activity going on, and this information is very nice to have, when interpreters are doing interpretation, and the speaker stops speaking.
This is the default setting.
The setup menu has the following options:
Amb.Mic When ‘enabled is selected, the Ambient Noise Microphone is active.
An interpreter turning on his microphone on an A- channel will interrupt another interpreter using his A channel
When the LineIn>Loudspk under Audio control is set to a value between -40dB and +20dB the microphone will be disabled. If the LineIn>Loudspk subsequently is set to Off, the microphone will stay disabled until enabled in Amb.Mic.
An interpreter turning on his microphone on an A- channel will interrupt another interpreter using his B channel, but will not interrupt an interpreter using his A channel.
Amb.Mic Level Adjust the level of the microphone to a level, which is suitable for the listener (Interpreter).
An interpreter turning on his microphone on an A- channel will interrupt another interpreter using his A or B channel.
Channel Display This setting is used to switch the showing in the channel selectors displays in conference units between Language Abbreviation and Channel Number.
The user returns to the main menu by pressing either the Menu button or the Enter button.
Units info Selecting “Units info” from the Main menu, the Units info menu is entered:
Ambient microphone By choosing ‘Ambient Microphone’ from the main menu and parameters for an AM 6040 Ambient Noise microphone can be set up
Display Chain Info Selecting the first select button makes the system enter the Chain Information display. This display looks like this:
The purpose of an ambient noise microphone is to provide sound from a meeting room/conference hall, when there is no delegate/chairman using their microphones.
A interrupt A · A interrupt B · A interrupt A+B

The Chain info menu displays information to the user about units connected to the CU. The information is divided into Chain A, Chain B and total. Found units are connected units, where the communication is maintained, and expected units comprises all units, which are defined in the ‘Configuration’.
The “Input mode” defines whether the ASCII communication via RS232/RS422 is protected by CRC check or not.
By protecting the communication (“Protected”), the risk of faulty communication via RS232/RS422 is minimized.
The risk of faults via RS232/RS422 is higher running the “Default” mode; however, the communication is possible from standard interfaces.
Menu button or Enter button leaves this screen.
Display Unit types Selecting the Display Unit types in the Units info menu displays the number of present units. The available units are:
The RS232 terminal interface emulator, Tera Term, does not feature the possibility of guarding the ASCII communication by CRC check.
Security setup The setup determines if ”Audio Scrambling” is activates or not.
Default value is ‘off’. When switching to ‘on’, the CU has to be restarted. All units will automatically change to the scrambled mode.
For external control it is indicated by ‘ON’ or ‘OFF’ whether an external PC is connected and communicating (alive) via the RS232/RS422 connection to the CU.
The scrambling mode is used in high security places, when ears dropping cannot be accepted.
Configuration The “Configuration” menu comprises three menu items:
Menu button or Enter button leaves this screen.
RS232 setup The RS232 setup menu consists of two setup issues:
Load configuration The “Load configuration” item brings the user to the Load configuration confirmation display:
RS232 baudrate The “RS232 baudrate” determines the bit rate of the communication between the CU and an external unit connected via the RS232 or RS422 connection.
This will overwrite Current setup. Continue?
RS232 mode

The load is aborted with the Menu button and accepted with the Enter button. In both cases, the menu system returns to the Main menu.
When switching the power to the CU 6010 OFF and then ON, the last saved setting will also be loaded.
Delete configuration The “Delete configuration” item brings the user to the Delete configuration confirmation display:
Save configuration If the “Save configuration” item is chosen this confirmation display is shown:
This will delete the configuration in flash. Continue?
This will overwrite the configuration in flash. Continue?
If the user accepts the deletion the progress display is shown:
If the user accepts the save the progress display is shown:
Deleting...
Saving...
The display is shown for a few seconds before the CU returns to the “Main menu”.
The display is shown for a few seconds before the CU returns to the “Main menu”.
License info menu Selecting the License info menu displays the available features enabled by the current license. The available features are:
Understanding “Save” and “Load” configuration When saving the configuration, the setting that has been done in the various menus in CU 6010, at the IS 6132 Interpreter Sets and at AO 6008 Audio Unit will be saved in the ‘Flash’ memory in the CU 6010.
Also the serial number and type of all units connected to the CU 6010 at the time of saving the configuration will be saved in the ‘Flash’ memory in the CU 6010.
Firmware info menu By choosing ‘Firmware info’ from the main menu information about the software version of the PowerPC and the DSP is shown as well as the Serial Number of the unit:
When switching on power to the CU 6010 at a later stage, then the units connected will be compared to the saved configuration. If some units are not present, they will be reported as ‘missing’
When ‘loading’ a configuration the last settings, which has been saved in the ‘Flash’ memory in the CU 6010 will be re-loaded to the CU 6010, to the IS 6132 Interpreter Sets and to the AO 6008 Audio Unit.

The user returns to the main menu by pressing either the Menu button or the Enter button.
This screen is the standard screen showed at normal use. This screen is automatically shown if no buttons is pressed in 2 minutes. The function of this screen is explained in the section Audio Control menu.
Powering up Switch on power at the CU 6010. After powering up, the display on the CU 6010 is showing the Start-up screen:
Use with SW 6000 Please refer to the SW 6000 manuals.
Schematics volume/gain settings The volume controls, which can be set on the CU 6010 user interface as described in the previous section are shown in the following schematic.
Setting of Loudspeaker volume 1. Set the Mic>Loudspk to 0dB
Digital Conference System 6000 DIS
Setting Line input level 1. Apply the signal to the Input connector
Registration Mode Unit registration Microphones disabled
After initialising the following screens are displayed:
”*” Overflow indicator on line input
-Audio control ▲ -Delegate setup -Interpreter setup -Ambient Microphone ▼
The principle is that the level of signal from the Line Input is combined of two settings:
“LinelnLevel Adj” and “LineIn->Loudspk”.
Initializing · Please Wait

The LinelnLevel Adj has to be set as high as possible for maintaining the best S/N ration, but not too high to avoid clipping, whereas the LineIn-
>LoudSpk is used for setting the audio level needed in the loudspeakers.
CU 6010 Orignal Audio Volume Control

General description
The functionality of CU 6011 is identical to the CU 6010 Central Unit.

General description
The functionality of CU 6005 is basically identical to the CU 6010 Central Unit; however the main parts are slightly different:
The optional Feature Licenses for the CU 6005 are the same as for the CU 6010 Central Unit with the following differences:
The features of the CU 6005 are almost the same as for the CU 6010 Central Unit with the following differences:

Front plate layout Identical to the CU 6010 Central Unit.
Front plate controls Identical to the CU 6010 Central Unit.
Back Panel Connectors As the CU 6010 Central Unit with the following differences:
The same as for the CU 6010 Central Unit.
Chain A1 & A2 (no chain B1 & B2) RJ45 connector, 2 pieces
The same as for the CU 6010 Central Unit.
DCS-LAN connectors for connection to DM/CM 6xxx, IS 6132, CS 6032, EX 6010, AO 6004/6008 etc. For connecting Interpreter Sets for up to 16 languages.
Slot (extra) Slot for inserting modules in the back panel, e.g. AO 6004. Slot dimensions (W x H x D) 180 x 38 x 120 mm.

Connect the CU 6005/6010/6011 to the various DCS 6000 units using Cat5 or Cat5e FTP or STP screened cables.
between the units. Please consult the next section ‘Maximum number of units to be connected’.
The operation of the DCS 6000 units is found in the User Manual for the specific units.
Please observe the following guidelines:
It is desirable that the square of the feeding cables especially but also the interconnection cables are as big as possible to minimize the voltage drop in the cables. Cat 5/Cat5E cables are delivered in various gauges:
The following table is showing the Diameter/square for various AWG types:
Type Diameter Square AWG22 0.64 mm 0.32 mm2
AWG23/1 0.57 mm 0.25 mm2
AWG24 0.53 mm 0.22 mm2
AWG26 0.42 mm 0.14 mm2
The unit has a built-in fan taking air in at the right side of the unit and blowing the hot air out at the right side. That allows units in 19” racks to be
stacked close with other units without extra room for cooling air between them. Please check that the other units will allow this.

The following table shows the maximum number of units, which can be connected to each of the four outputs (A1, A2, B1 or B2) on a CU 6010/6011
Central Unit or on each output on an EX 6010 Extension Unit or on the output of a PS 6000..

10 m 1 m 51 m 42 30 m 1 m 67 m 38 50 m 1 m 83 m 34 100 m 1 m 122 m 23 150 m 1 m 165 m 16 10 m 2 m 88 m 40 30 m 2 m 98 m 35 50 m 2 m 108 m 30 100 m 2 m 140 m 21 150 m 2 m 178 m 15
The following table shows the maximum number of units, which can be connected to the two outputs (A1 and A2) simultaneously on a CU 6005 in total
If only one chain is used the information in the above table must be used.

10 m 1 m 2x32 m 2x23 30 m 1 m 2x51 m 2x22 50 m 1 m 2x70 m 2x21 100 m 1 m 2x117 m 2x18 150 m 1 m 2x164 m 2x15 10 m 2 m 2x54 m 2x23 30 m 2 m 2x72 m 2x22 50 m 2 m 2x88 m 2x20 100 m 2 m 2x132 m 2x17 150 m 2 m 2x176 m 2x14
This configuration shows two CM/DM 60x0P Delegate/Chairman Units connected to one JB 6002 Junction Box with 3m cables between each JB 6002.
Maximum 5 m cable from JB 6002 to CM/DM 60x0 and maximum one CM/DM 60x0 on each output of JB 6002.


10 m 3 m 61 m 18 36 30 m 3 m 75 m 16 32 50 m 3 m 89 m 14 28 100 m 3 m 127 m 10 20 150 m 3 m 168 m 7 14
The following table shows the maximum number of units, which can be connected to each of the four outputs (A1, A2, B1 or B2) on a CU 6010/6011
Central Unit or on each output on an EX 6010 Extension Unit or on the output of a PS 6000.

Total cable length Max. number of CM/DM 60x0 pr output
10 m 1 m 39 m 30 30 m 1 m 56 m 27 50 m 1 m 73 m 24 100 m 1 m 115 m 16 150 m 1 m 160 m 11 10 m 2 m 64 m 28 30 m 2 m 78 m 25 50 m 2 m 94 m 23 100 m 2 m 130 m 16 150 m 2 m 170 m 11
The following table shows the maximum number of units, which can be connected to each of the four outputs (A1, A2, B1 or B2) on a CU 6010/6011
Central Unit or on each output on an EX 6010 Extension Unit or on the output of a PS 6000.

10 m 1 m 35 m 27 30 m 1 m 53 m 24 50 m 1 m 70 m 21 100 m 1 m 113 m 14 150 m 1 m 159 m 10 10 m 2 m 58 m 25 30 m 2 m 72 m 22 50 m 2 m 88 m 20 100 m 2 m 126 m 14 150 m 2 m 166 m 9

The following table shows the maximum number of units, which can be connected to each of the four outputs (A1, A2, B1 or B2) on a CU 6010/6011
Central Unit or on each output on an EX 6010 Extension Unit or on the output of a PS 6000.

Total cable length Max. number of DC 6990P pr output
10 m 1 m 35 m 26 30 m 1 m 53 m 24 50 m 1 m 70 m 21 100 m 1 m 112 m 13 150 m 1 m 158 m 9 10 m 2 m 56 m 25 30 m 2 m 72 m 22 50 m 2 m 90 m 19 100 m 2 m 124 m 13 150 m 2 m 166 m 9
The following table shows the maximum number of units, which can be connected to the two outputs (A1 and A2) simultaneously on a CU 6005 in total
If only one chain is used the information in the above table must be used.

Total cable length Max. number of DC 6990 for both outputs
10 m 1 m 2x34 m 2x15 30 m 1 m 2x43 m 2x14 50 m 1 m 2x62 m 2x13 100 m 1 m 2x110 m 2x11 150 m 1 m 2x158 m 2x9 10 m 2 m 2x36 m 2x14 30 m 2 m 2x54 m 2x13 50 m 2 m 2x90 m 2x12 100 m 2 m 2x118 m 2x10 150 m 2 m 2x164 m 2x8

This table shows the maximum number of MU 6040 Microphone Units, which can be connected to each of the four outputs (A1, A2, B1 or B2) on a CU 6010/6011 Central Unit or on each output on an EX 6010 Extension Unit or on the output of a PS 6000.
The numbers are valid with no audio in loudspeaker (no loudspeaker connected to each unit). If loudspeakers are used, then use the figures for CM/DM 60x0P above.

10 m 2 m 168 m 80 30 m 2 m 178 m 75 50 m 2 m 188 m 70 100 m 2 m 200 m 51 150 m 2 m 200 m 26 100 m 1 m 151 m 52 150 m 1 m 191 m 42
The tables below shows the maximum number of IS 6132P Interpreter Sets, which can be connected to each of the four outputs (A1, A2, B1 or B2) on a CU 6010/6011 Central Unit or on each output on an EX 6010 Extension Unit or on the output of a PS 6000.
If loudspeakers are used, then use the figures for CM/DM 60x0P above.
The numbers are with no audio in loudspeaker (no loudspeaker connected to each unit).

10m 2 m 54 x x 30m 2 m 49 57 60 50m 2 m 44 51 x 100m 2 m 35 40 x 150m 2 m 25 30 x


10 m 5 m 19 4 0 10 m 5 m 12 4 4 30 m 5 m 17 4 0 30 m 5 m 10 4 4 50 m 5 m 15 4 0 50 m 5 m 9 4 4 100 m 5 m 11 4 0 100 m 5 m 7 4 4 150 m 5 m 8 4 0 150 m 5 m 5 4 4
The tables below shows the maximum number of CS 6032F Channel Selectors, which can be connected to each of the four outputs (A1, A2, B1 or
B2) on a CU 6010/6011 Central Unit or on each output on an EX 6010 Extension Unit or on the output of a PS 6000.

Total cable length Max. number of CS 6032 pr
30 m 1 m 139 m 110 50 m 1 m 144 m 95 100 m 1 m 184 m 85 150 m 1 m 200 m 51 10 m 2 m 200 m 96 30 m 2 m 200 m 86 50 m 2 m 200 m 76 100 m 2 m 200 m 51 150 m 2 m 200 m 26

The following schematics are showing various configurations:







Microphone conference system with 15+1 ch. interpretation & IR, CU 6010









CAT6 can thus only be used for longer cable draws terminating in wall outlets or patch panels.
CAT5 The DCS 6000 system uses CAT5, CAT5e or CAT6 FTP or STP cables with screened RJ45 connectors.

1 * 1 DCD 2 TxD 2 RxD 3 RxD 3 TxD 4 * 4 DTR 5 0V 5 0V 6 * 6 DSR 7 RTS 7 CTS 8 CTS 8 RTS 9 9 RI Connect all pins in the connectors: Pin 1 to Pin 1, Pin 2 to Pin 2, Pin 3 to Pin 3 and so on.
EIA 568-B wiring shall be used.
It is important to use only FTP or STP (screened) cables and screened RJ45 connectors and not UTP cable, which is unscreened.
How to wire a CAT5 (EIA 568-B) Cable:

1 In-going + ORG/WHT ORG/WHT 2 In-going - ORG ORG 3 +48V GRN/WHT GRN/WHT 4 0V BLU BLU 5 0V BLU/WHT BLU/WHT 6 +48V GRN GRN 7 Outgoing - BRN/WHT BRN/WHT 8 Outgoing + BRN BRN
* Pin 1, 4 and 6 are connected together inside the CU 6005/6010/6011.

1 RXD+(B) 1 2 RXD-(A) 2 3 TXD-(A) 3 4 TXD+(B) 4 5 0V 5 6 RTS-(A) 6 7 RTS+(B) 7 8 CTS+(B) 8 9 CTS-(A) 9
pairs are connected as follows:
The phase of the pairs must be correct and
the wiring spec. as stated in CAT5 (EIA 568-B) have to be followed.
the RS422. Please consult the manual for the RS422 card in your PC or control system.

Please observe that either the RS232 Serial Connection or the RS422 Serial Connection can be used. It is not possible to use both at the same time.
Cat 5 Connection Cables (AWG24)
EC 6000-0.5 Connection Cable 0.5 m 10 03 12500
EC 6000-01 Connection Cable 1 m 10 03 13101
EC 6000-02 Connection Cable 2 m 10 03 13201
Pin Signal Cable type
EC 6000-05 Connection Cable 5 m 10 03 13501
1 Ground 2 In phase signal 3 Out phase signal
DIS type #2914 or 2 x 0.25 mm2 shielded.
EC 6000-10 Connection Cable 10 m 10 03 14102
EC 6000-20 Connection Cable 20 m 10 03 14202
EC 6000-50 Connection Cable 50 m 10 03 14502
Pin Signal Cable type
EC 4010-05 Connection Cable 1 m 15 51 05563
DIS type #2914 or 2 x 0.25 mm2 shielded.
1 Ground 2 In phase signal 3 Out phase signal
EC 4010-05 Connection Cable 2 m 15 51 05564
EC 4010-05 Connection Cable 5 m 15 51 05565
EC 4010-05 Connection Cable 10 m 15 51 05566
RS232 cables

Digital Section
Connectors
Sound quality 24 bit audio @ 32 kHz sampling frequency
DCS 6000 network chain (DCS-LAN) RJ45
2 pieces (CU 6005)
Floor output signal type electronically balanced
4 pieces (CU 6010/6011)
Nominal output level -8 dBm at nominal input
Maximum number of units to be connected to the two outputs in total on a CU 6005 or to each chain of the four outputs on a CU 6010/6011:
Max. output level 3.5V RMS ∼ +13 dBm
Line input signal type electronically balanced
MU 6040 Microphone Units up to 80 pieces
Nominal input level (adjustable)
DM/CM 60x0P Delegate/Chairman Unit ...up to 42 pieces
+6 to -30 dBm (1.55 V RMS to 25 V RMS)
IS 6132P Interpreter Set up to 54 pieces
Max. input level +30 dBm (25V RMS)
CS 6032F Channel Selector up to 110 pieces
Line input impedance 25-50 kohm
The actual maximum number of units depends on the length of the feeding cable and interconnection cables
Frequency response 50-15kHz
Line output XLR3 male connector
Line input XLR3 female connector
RS 232 (with hardware handshake) D-Sub 9 female
RS 422 (with hardware handshake D-Sub 9 male
Power consumption max. 150W (CU 6005)
either the RS232 or the RS422 can be used
max. 600W (CU 6010/6011)
In-rush current max. 30A@115V or max. 60A@230V
Max. number of conference units 3800 (CU 6010/6011)
Supply voltage for units
Max. number of conference units 500 (CU 6005)
Max. number of units (excl. CS) 4000
Max. number of IS 6xxx in one booth 32
Temperature to guarantee specified performance
Max. number of IS 6xxx 150
5 Deg C. to 40 Deg C. (35 to 80% humidity)
Max. number of AO 6004/6008 20
Storage temp -20 Deg C. to 60 Deg C. (10 to 80% humidity)
Max. number of CS 6032 practically unlimited
Weight 5.7 kg (CU 6005)
Max. number of languages 16 (CU 6005)
6.2 kg (CU 6010/6011)
Dimensions (W x H x D) 425 (483) x 87 x 317 (357) mm
Dimensions in bracket are including 19” brackets
Max number of open microphones 8
Slot dimensions (W x H x D) 180 x 38 x 120 mm (CU 6005)
The DCS 6000 system conforms to all relevant standards - e.g. IEC 914, ISO 4043, and ISO 2603
Accessories supplied User manual
Mains cable
5 pieces termination plugs
Specifications are subject to change without notice.