EN
Listen Technologies logo
Official user manual

Listen Technologies CU 6005

39 pages·3 MB·Stereo Receiver·PDF·ENDEFRITNLJA
Listen Technologies CU 6005
Table of Contents 61 sections DCS 6000 · User Manual · Digital Conference System · Danish Interpretation Systems DIS · … ShowHide
DCS 6000p.1User Manualp.1Digital Conference Systemp.1Danish Interpretation Systems DISp.1Importantp.5Compliancyp.5The equipment must be connected to earthp.5Labelsp.5Important safety instructionsp.5Installation precautionsp.5Warrantyp.6Cleaning & Repackingp.6Description of the DCS 6000 systemp.7Featuresp.7System componentsp.8Voting equipmentp.8Operating instructionsp.9CU 6010 Central Unitp.9General descriptionp.9Feature Licensep.9User Controls, indications & connectorsp.10Indicationsp.11Back Panel Layoutp.12Back Panel Connectorsp.12System settingsp.12Normal Operationp.20CU 6011 Central Unitp.21CU 6005 Central Unitp.22Otherp.23System Setupp.24General guidelinesp.24Built into 19” Racksp.24Maximum number of units to be connectedp.25CM/DM 60x0P Chairman/Delegate Units & JB 6002 Junction Box – CU 6010/6011p.25CM/DM 6060F/6510F Chairman/Delegate Units – CU 6010/6011p.26DC 6990P Conference Units – CU 6010/6011p.27DC 6990P Conference Units – CU 6005p.27MU 6040C/D and MU 6042D without connected loudspeaker – CU 6010/6011p.28IS 6132P Interpreter Units – CU 6010/6011p.28IS 6132P w/JB 6004 and LS 6032 – CU 6010/6011p.29CS 6032F Channel Selector w/back light on – CU 6010/6011p.29Typical schematicsp.30Small conference microphone system with CU 6005p.30Small conference microphone system with CU 6010p.30Microphone conference system with 3+1 ch. interpretation & IR, CU 6005p.32Microphone conference system with 15+1 ch. interpretation & IR, CU 6010p.32Various configurations with RP 6004 Repeater and PS 6000 Power Supplyp.33Small system with SW 6000 Conference Management Softwarep.34Large system with SW 6000 Conference Management Softwarep.35RS 232 Serial connectionp.36RS 422 Serial connectionp.36Accessories (not supplied)p.37Analog Audio, Line output (XLR3 male)p.37Analog Audio, Line Input (XLR3 female)p.37Technical specificationsp.38Digital Sectionp.38Connectorsp.38Analogue Sectionp.38Generalp.38System performance with CU 6005/6010/6011 as central unitp.38.................................................................... 31 (CU 6010/6011)p.38
Page 1 of the Listen Technologies CU 6005 user manual — Danish Interpretation Systems DIS
Page 1 · click to enlarge
Page 1

DCS 6000

Listen Technologies CU 6005 — DCS 6000 diagram (page 1)
Fig. 1

User Manual

Digital Conference System

Listen Technologies CU 6005 — Digital Conference System diagram (page 1)
Fig. 2 · Digital Conference System

CU 6005/6010/6011 Central Unit Central Unit for series DCS 6000 Voting Units, Conference Units, Interpreter Units, Ambient Noise Microphone, Channels Selectors and Audio Output Units

Danish Interpretation Systems DIS

Page 2 of the Listen Technologies CU 6005 user manual — DCS 6000
Page 2 · click to enlarge
Page 2

Copyright © 2007 DIS CU6005 6010 6011 REV V.DOC 16-07-2007

No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher.

Page 3 of the Listen Technologies CU 6005 user manual — DCS 6000
Page 3 · click to enlarge
Page 3
Page 3 of the Listen Technologies CU 6005 user manual — DCS 6000
Page 4 of the Listen Technologies CU 6005 user manual — DCS 6000
Page 4 · click to enlarge
Page 4

Microphone conference system with 3+1 ch. interpretation & IR, CU 6005 32

Appendix 36

Technical appendix 36

Microphone conference system with 15+1 ch. interpretation & IR, CU 6010 32

Cabling 36

Accessories (not supplied) 37

Various configurations with RP 6004 Repeater and PS 6000 Power Supply 33

Technical specifications 38

Small system with SW 6000 Conference Management Software 34

Large system with SW 6000 Conference Management Software 35

Copyright © 2007 DIS CU6005 6010 6011 REV V.DOC 16-07-2007

No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher.

Page 5 of the Listen Technologies CU 6005 user manual — Important safety instructions
Page 5 · click to enlarge
Page 5

Important

Compliancy

The equipment must be connected to earth

The equipment has been tested and found to comply with the limits of the following standards for digital devices:

Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus.

  • EN55103-1 (Emission)
  • EN55103-2 (Immunity)
  • EN60065 safety
  • UL6500 safety
  • FCC rules part 15, class A (Emission)

Labels

Lightning Flash Symbol, with "The Lightning Flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product enclosure that may be of sufficient magnitude to constitute a risk of shock to persons"

The device complies with part 15 of the FCC rules. Operation is subject to the following conditions: (1) The device may not cause harmful interference, and (2) the device must accept any interference received, including interference that may cause undesired operation.

Listen Technologies CU 6005 — Labels diagram (page 5)
Fig. 3 · Labels

These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in residential, commercial or light industrial environments. The equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the user manual it may cause harmful interference to radio communications.

Listen Technologies CU 6005 — Labels diagram (page 5)
Fig. 4 · Labels

Exclamation Point Symbol, with "The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product"

You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.

Important safety instructions

Installation precautions

Check that the voltage of your local power supply is within the operating voltage of the unit (100-240V AC). If a voltage conversion is required, consult your DIS dealer or qualified personnel.

Allow adequate air circulation to prevent internal heat built-up. Do not place the unit on a surface (rugs, blankets, etc.) that may block the ventilation holes.

Should any liquid or solid object fall into the cabinet, unplug the unit and have it checked by qualified personnel before operating it further.

Do not install the unit in a location near heat sources such as radiators or air ducts, or in a place exposed to direct sunlight, excessive dust or humidity, mechanical vibration or shock.

Set the Power switch to OFF if it is not used for several days.

Page 6 of the Listen Technologies CU 6005 user manual — Cleaning & Repacking
Page 6 · click to enlarge
Page 6

To avoid moisture condensations do not install the unit where the temperature may rise rapidly.

Warranty

When installing the unit inside a 19” rack, observe that the rack is properly ventilated. The maximum allowed temperature inside the rack is 40 °C.

The unit is minimum covered by 12 months warranty against defects in materials or work- manship.

Cleaning & Repacking

To keep the cabinet in its original condition, periodically clean it with a soft cloth. Stubborn stains may be removed with a cloth lightly dampened with a mild detergent solution. Never use organic solvents such as thinners or abrasive cleaners since these will damage the cabinet.

Save the original shipping cardboard box and packing material; they will become handy if you ever have to ship the unit. For maximum protection, re-pack the unit as originally packed from the factory.

Page 7 of the Listen Technologies CU 6005 user manual — Features
Page 7 · click to enlarge
Page 7

Description of the DCS 6000 system

Features

  • Added functionality and comprehensive features provided by SW 6000 software package running on PC

The DCS 6000 system has the following main features:

RS232/RS422 connection on CU 6005/6010/6011 for external operation of the system of a PC or control system such as AMX or Crestron

  • Fully digital
  • Excellent sound quality

The SW 6000 is an optional software package, which expands the functionality of the DCS 6000 system. The software runs on standard computer technology (Standard PC with Windows 2000 or XP).

  • “State of the Art” fully digital integrated interpretation, discussion and voting system offering interpretation, language distribution, conference microphone and voting facilities with attendance check with Chip Card ™.
  • Unique digital DATA and AUDIO bus.

Main features of the SW 6000 are:

  • Microphone management
  • 39 incoming channels (8 floor channels + 31 interpreted channels) and one Line input.
  • Mimic panel operation
  • 34 distributed channels (3 x floor + 31 interpreted channels)
  • Interpretation management
  • Voting management
  • The Delegate and Interpreter units are powered and controlled by the CU 6005 Central Unit, which drives up to app. 50 units on 2 chains or by the CU 6010/6011 Central Unit, which drives up to app. 200 units on 4 chains.
  • Message handling
  • Agenda handling
  • Data stored on SQL data base
  • EX 6010 Extension Units or PS 6000 Power Supplies available if more units are required
  • Web service interface available for easy links to external applications
  • A total of 4000 units (delegate and/or interpreter units) can be connected to the system.
  • Multi language user interfaces
  • Supports different User types with different priorities, user interfaces and control possibilities
  • Using screened CAT5 or CAT5e cabling (FTP or STP) ensuring a very cost effective installation and easy set-up of portable systems
  • Variety of printing facilities such as speaker’s log, voting results, delegates list etc.
  • Firmware in Delegate units, Interpreter Units, Central Units etc. upgradeable through serial PC-connection (RS232 or RS422)
  • Can be operated with or without a PC.
Page 8 of the Listen Technologies CU 6005 user manual — Voting equipment
Page 8 · click to enlarge
Page 8

Conference equipment and channel selectors

System components

The CU 6005/6010/6011 Central Unit supports all available units in the DCS 6000 series:

CS 6032F V/H Channel Selector (flush mounted) DC 6990P Conference Unit (portable) with touch screen DM 6010P Conference Unit (portable) DM 6060P Conference Unit (portable) with one built-in channel selector CM/DM 6070P Conference Unit (portable) with two built-in channel selectors CM/DM 6090P Conference Unit (portable) with two built-in channel selectors and XLR microphone connector CM/DM 6060F Conference Unit (flush mounted)

Central equipment etc.

EX 6010 Extension Unit PS 6000 Power Supply AO 6004 Audio Output box AO 6008 Audio Output box RP 6004 Repeater for four chains JB 6002 Junction Box with 2 outputs JB 6004 Junction Box with 4 outputs

with one built-in channel selectors CM/DM 6510F Conference Unit (flush mounted) with Chip-card and 3 voting buttons CM/DM 6560F Conference Unit (flush mounted) with one built-in channel selector, Chip-card and 3 voting buttons MU 6040C/D Microphone Unit for use with customised front plate with Loudspeaker, Microphone and Buttons. Available in Delegate (D) and Chairman (C) version MU 6042D Dual Microphone Unit for use with FD/FC front plate with Loudspeaker, Microphone and two delegate Buttons AM 6040 Ambient Noise Microphone

IS 6132P Interpreter Set LS 6132P Interpreter Loudspeaker

Voting equipment

DV 6501F Voting Unit

Interpreter equipment

Page 9 of the Listen Technologies CU 6005 user manual — Features
Page 9 · click to enlarge
Page 9

Operating instructions

CU 6010 Central Unit

  • Delayed switching on of power to the four chains, to minimise the total ‘in-rush’ current on the Mains supply.

General description

  • Designed in a standard 2HE 19” cabinet.

The CU 6010 Central Unit for the DCS 6000 is the heart of the system. One CU 6010 is needed in each DCS 6000 system. The CU 6010 consist of four main parts:

  • Functionality on the CU 6010 depends on the Feature License uploaded into the unit.

Feature License

  • Main processor board with Power PC and DSP

The CU 6010 Central Unit has as standard basic functionality.

  • DCS-LAN Network Control Card with 4 individual DCS-LAN outputs
  • Conference Units: max. 50 This count includes DM, CM, DV units. Dual Delegate units count for 2 units.
  • Secure audio transmission: No
  • Vox, voice activating: No
  • Voting: No
  • Interpretation Channels: 1-4 By obtaining feature licenses, the functionality can be expanded to include further functionality like:
  • 4 individual Power supplies
  • LCD display and buttons for system settings

The design with built in power supply makes the unit suitable for running a small system alone or to be the Central Controller for a large system.

Features

The main features of the CU 6010 Central Unit are:

  • Conference Units, max.100, max. 500, max. 1000 or max. 3800 This count includes DM, CM, DV units. Dual Delegate units count for 2 units
  • Secure audio transmission
  • Voting option
  • VOX, Voice Activation
  • Interpreter Channels, 1-8 channels, 1-16 channels or 1-31 channels
  • 3 part voting control using RS232 port on CU 6010 The file with the Feature License key is delivered from your authorised DIS Distributor or Dealer and can be uploaded in the CU using a standard PC or Laptop. For details about uploading the Feature license, please consult the User Manual “DCS6000 Feature License Key”.
  • Controls up to 4000 units (Conference units, Interpreter units or other controllable units). This number does not include Channel Selectors, Repeaters etc. In practical use there are no limits for the number of Channel Selectors in a system.
  • Designed for 31 interpreted channels and 8 open microphones
  • Operated either stand alone or from an IBM compatible PC with SW 6000 software running under Windows 2000 or XP.
  • Built in Power Supplies for app 200 units (Delegate) or app. 600 Channel Selectors
  • 4 outputs for connection to Delegate Units, Interpreter Units etc.

This manual describes all features available

Page 10 of the Listen Technologies CU 6005 user manual — User Controls, indications & connectors
Page 10 · click to enlarge
Page 10

User Controls, indications & connectors

Front plate layout The front plate layout of the CU 6010 Central Unit consists of a large illuminated LCD display and 8 buttons for setting up/controlling the system:

Listen Technologies CU 6005 — User Controls, indications & connectors diagram (page 10)
Fig. 5 · User Controls, indications & connectors
Listen Technologies CU 6005 — User Controls, indications & connectors diagram (page 10)
Fig. 6 · User Controls, indications & connectors

Details of display

Front plate controls The CU 6010 Central unit features the following controls and display:

The Fault LED will always light up some seconds after the unit is switched on caused by the delayed switching on of the four supplies.

As a warning the light is flashing at an internal temperature above 45°C. At a temperature above 55°C or if one of the DCS-LAN outputs is supplying no voltage, the LED is lighting constantly.

Power switch Switches power on to the whole system. When power is switched ON at the CU 6010 any connected EX 6010 Extension Units will automatically be powered up. An indication in the switch is lighting, when power is switched ON

Please note that the maximum ambient temperature for the CU 6010 is 40 deg. Celsius.

Fault LED This indication lights up, if the internal power supply is malfunctioning i.e. because of overheating or overload of a chain.

LCD Display This display is used for information purposes and set-up purposes.

Page 11 of the Listen Technologies CU 6005 user manual — Indications
Page 11 · click to enlarge
Page 11

Buttons The buttons below and to the left of the display are used when stepping through the different menus and for setting up the system:

‘-‘ The dash symbol (‘-‘) preceding a line of text identifies a submenu or a changeable parameter. The submenu or parameter can be selected by pressing the corresponding select button.

  • Four select buttons Four buttons placed on the left-hand side of the display. Each button is associated with a line pointing towards a text line in the display. This indicates, that pushing the button ‘selects’ the functionality.

‘>’ The ‘>’ symbol preceding a line of text identifies a selected parameter. The parameter can be changed by pressing the up and down buttons. The ‘>’ symbol is shown as long as the value of the parameter currently used is the same as the value shown in the display.

  • Enter button The Enter button is used, when a selection is made in the Main Menu. Pressing the Enter button concludes the selection made, and at the same time it indicates a confirmation of the possible changes made within the selection. The Menu system returns to the previous menu. Notice, that some changes are applied immediately, and confirmation is thus not required.

‘*’ The star symbol ‘*’ preceding a line of text identifies a selected parameter, where the value has been changed, but not yet confirmed. The changed value can be confirmed by pressing the Enter button, or it can be dismissed by pressing the Menu button.

  • Menu button The Menu button is also used, when a selection is made in the Main Menu. The Menu button concludes the selection, but in contrast to the Enter button, the Menu button does not confirm a possible change made within the selection. Instead, the Menu system returns to the previous menu without confirming changes, if confirmation is required.

‘▲▼’ The up and down symbols shown in the right side of the display (up is shown in the first line and down is shown in the last line) indicates that the current menu consists of more than 4 menu items. It is therefore necessary to use the up and down buttons to scroll through menu items.

Indications

  • Up ( ▲ ) and Down ( ▼ ) buttons The Up and Down buttons are used to scroll through menu items, or to increase/decrease values within a selection.

Cursor The cursor is used on the LCD display to indicate, when a value is being changed. For a parameter that is subject to a change, the cursor is placed at the value of the parameter, indicating that it is about to be changed.

Symbols The following symbols are used on the LCD display:

Page 12 of the Listen Technologies CU 6005 user manual — System settings
Page 12 · click to enlarge
Page 12

Back Panel Layout

Listen Technologies CU 6005 — Back Panel Layout diagram (page 12)
Fig. 7 · Back Panel Layout

Back Panel Connectors

Interpreter sets for those languages have to be connected to Chain B1 or B2.

Mains Power connector Connection for mains power. See specs.

Chain B1 & B2 RJ45 connector, 2 pieces

Analog Audio Line input XLR Input connector.

DCS-LAN connectors for connection to DM/CM 6xxx, IS 6032, IS 6132, CS 6032, EX 6010, AO 6004/6008 etc. For connecting Interpreter Sets for up to 16 languages. If more languages are required, Interpreter sets for those languages have to be connected to Chain A1 or A2.

For connection of external Line input signal i.e. the Floor (Speaker) signal from another Conference Microphone System or audio mixers. See specs.

Analog Audio Line output. XLR Output connector.

Power LED’s Those LED’s light up when Power is available on the connector next to the LED and only if the voltage is over 24V (not overloaded).

This connector carries the “Floor” signal. It is used either for recording purposes or for feeding signal to an external loudspeaker system. See specs.

System settings

Serial Data Communication RS232 D-Sub9 connector

Control of the system settings is done through selections made in the main menu. Pressing the Menu button will show the Main menu, which comprises the following entries:

RS232 Serial connection for communication to PC etc. Either the RS232 or the RS422 can be used.

Serial Data Communication RS422 D-Sub 9 connector

  • Audio control
  • Delegate setup
  • Interpreter setup
  • Ambient Microphone
  • Units info
  • RS232 setup
  • Security setup
  • Configuration
  • License info
  • Firmware info

RS422 Serial connection for communication to PC etc. Either the RS232 or the RS422 can be used.

Chain A1 & A2 RJ45 connector, 2 pieces

DCS-LAN connectors for connection to DM/CM 6xxx, IS 6032, IS 6132, CS 6032, EX 6010, AO 6004/6008 etc. For connecting Interpreter Sets for up to 16 languages. If more languages are required,

Page 13 of the Listen Technologies CU 6005 user manual — Back Panel Layout
Page 13 · click to enlarge
Page 13

A selection is made in the Main menu by scrolling through the menu items with the Up/Down buttons, and pressing the Select button associated with the desired menu item. When scrolling through the menu items, the Main menu wraps around the list of menu items, i.e. passing the last menu item makes the first menu item appear, and likewise when passing the first menu item.

The Audio Control menu comprises the following complete list of adjustment items:

Loudspk volume This is the Master Loudspeaker volume, the audio level of the loudspeakers of the delegate microphone units.

Values{Off, -40, -39, …, -1, 0}

Pressing the Menu and Enter buttons does not have any effect in the Main Menu.

LineOut volume The audio volume of the ‘LINE OUTPUT’ signal from the CU.

Audio control By pressing the select button for the “Audio Control” menu adjustment of the audio levels becomes possible:

Values{Off, -40, -39, …, 19, 20}

Mic->Loudspk Attenuation/Gain of the audio signal transmitted from speaking delegate microphones to the delegate microphone unit loudspeakers.

  • Loudspk volume
  • LineOut volume
  • Mic->Loudspk
  • Mic->LineOut
  • LineIn->Loudspk
  • LineIn->LineOut
  • LineInlevel Adj By pressing the first select button, adjustment of the loudspeaker volume is selected. This is indicated by the ‘>’-indicator, and the cursor starts flashing at the value:
Values{Off, -40, -39, …, 19, 20}

Mic->LineOut Attenuation/Gain of the audio signal transmitted from speaking delegate microphones to the ‘LINE OUTPUT’ signal.

Values{Off, -40, -39, …, 19, 20}

LineIn->Loudspk Attenuation/Gain of the audio signal transmitted from the ‘LINE INPUT’ to the loudspeakers of the delegate microphone units.

>Loudspk volume-7dB ▲ -LineOut volume: 4dB -Mic->Loudspk: -10dB -Mic->LineOut: 0dB ▼
Values{Off, -40, -39, …, 19, 20}

The up/down buttons can now alter the value of the loudspeaker volume. A change made to the loudspeaker volume takes effect immediately. The volume is changed in steps of 1 dB. The value of 0 indicates ‘standard’ setting.

LineIn->LineOut Attenuation/Gain of the audio signal transmitted from the ‘LINE INPUT’ to the ‘LINE OUTPUT’.

Values{Off, -40, -39, …, 19, 20}

Pressing the Menu or the Enter button ends change of loudspeaker volume. Change of other audio levels is done the same way as for the loudspeaker volume in steps of 1 dB. All changes take effect immediately.

LineInlevel Adj Attenuation/Gain of the XLR audio input signal from the ‘LINE INPUT’.

Values{Off, -40, -39, …, -1, 0}
Page 14 of the Listen Technologies CU 6005 user manual — Back Panel Layout
Page 14 · click to enlarge
Page 14

Delegate setup The “Delegate setup” menu comprises the following entries:

Values{Auto, Manual, FIFO, VOX}:
  • Auto (or Automatic) mode allows for the microphone units to be switched on immediately upon pressing the microphone ON/OFF button.
  • Max Speakers
  • Max. Requests
  • Operation Mode
  • Voice Detection
  • Auto Off Setup

This is indicated by a red light in the ‘Speak’ lamp in the microphone unit. Pressing the microphone ON/OFF button again will turn the microphone off

Max Speakers This menu point has two settings:

A Chairman Unit is always in Auto or VOX mode.

  • Max. Total Speakers
  • Max. Delegate Speakers
  • Manual mode features a request list, where ‘Delegates’ are inserted in a queue upon pressing the microphone ON/OFF button. This is confirmed by a steady green light in the ‘Request’ lamp in the delegate unit. It is possible to cancel the request by pressing the button again.
Values{1, 2, 3, 4, 5, 6, 7, 8}

The number of ‘Total Speakers’ defines the maximum number of conference units, which can speak at the same time. This includes both delegate and chairman units.

The microphone can only be switched on from a PC running SW 6000 software or from a control system like AMX or Crestron. This will be indicated by red light in the ‘Speak’ lamp in the microphone unit. At this point the delegate can switch off the microphone by pressing the ON/OFF microphone button.

The number of ‘Delegate Speakers’ defines the maximum number of Delegate conference units, which are allowed to speak at the same time is defined as “Max Speakers”.

Please observe that a Chairman Unit can always be switched ON as long as the number set in ‘Max. Total Speakers’ are not exceeded.

Although it is possible to switch to this mode in a stand-alone-system, this mode is only used with an attached PC running SW 6000 software or using with a control system.

Max Requests “Max Requests” defines how many delegate units that can be inserted into the list of delegates requesting to speak at the same time.

Values{0, 1, …, 255}
  • FIFO is an automated mode. The microphone unit functions in the same way as in automatic mode as long as the number of turned on delegate units is less or equal to the selected maximum speakers.

Operation Mode This menu point has two settings:

  • Operation mode
  • Interrupt

When the max. number is reached, the next delegate pressing the ON/OFF button will be put in the top of the request queue. This is indicated by the green ‘Request’ lamp flashing slowly.

  • Operation mode The “Operation Mode” determines the behaviour of the microphone system.
Page 15 of the Listen Technologies CU 6005 user manual — Back Panel Layout
Page 15 · click to enlarge
Page 15

More delegates will be put in the request queue when they press their ON/OFF buttons, until the maximum of requests is reached. Their green ‘Request’ lamps will light up steadily.

but 3 flashes in the green LED will indicate, that the maximum number has been reached.

It is similar for Chairman units if the number of open units (Chairman and Delegate) has reached the number specified in the setting “Max. Total Speakers”.

When one of the turned ON microphone units is switched off, the first delegate unit in the queue is automatically switched ON, and the next delegate unit in the queue will flash with the green ‘Request’ lamp.

Lower If however “Lower” is selected a chairman will interrupt (switch Off) the first switched On delegate unit if the number of open units (Chairman and Delegate) has reached the number specified in the setting “Max. Total Speakers”.

This mode will normally be used with only 1 as maximum speakers.

  • VOX, voice activation mode allows for the microphone units to be switched on automatically if speaking in the microphone or by pressing the microphone ON/OFF button.

Lower+Same If “Lower+Same” is selected a delegate unit will interrupt (switch Off) the first switched On delegate unit if the number of delegate units has reached the number specified in the setting “Max. Delegate Speakers”.

This is indicated by a red light in the ‘Speak’ lamp in the microphone unit. Pressing the microphone ON/OFF button again will turn the microphone off.

Similar a chairman will interrupt (switch Off) the first switched ON delegate unit if the number of open units (Chairman and Delegate) has reached the number specified in the setting “Max. Total Speakers”, and if no delegate unit is switched ON the first switched ON Chairman unit will be switched OFF.

The microphone turns of automatically after finished talking after the time defined in the “Release Time” setting (se later paragraph), which normally is 4 seconds. The microphone can also be turned off by pressing the ON/OFF button.

Voice Detection This menu point has two settings:

A Chairman Unit is always in Auto or VOX mode

  • Treshold
  • Release time
  • Interrupt The “Interrupt” setting determines the behaviour of the microphone units.

Those settings determines the behaviour of the system when working in VOX mode

Values{None, Lower, Lower+Same}
  • Treshold Values: {-5,-4,-3, -2, -1, 0,1,2,3,4,5}

None When “None” is selected and the number of open Delegate units has reached the number specified in the setting “Max. Delegate Speakers” no more delegate microphone can be opened. Pressing the microphone buttons will not turn on the microphone

The default value is ‘0’. Setting to a lower value makes the microphone more sensitive.

  • Release time Values: {from 1 to 10 seconds in 0.5 sec step}
Page 16 of the Listen Technologies CU 6005 user manual — Back Panel Layout
Page 16 · click to enlarge
Page 16

This setting is used to set the time from the delegate stops talking until the microphone turns off. The default value is 4 sec.

When set to 0 value no interpretation channels are present in the system. Only ‘Floor’ sound will be present

Channel 0 will always give the original audio (floor).

Auto Off Setup This menu point has two settings:

  • Auto Off
  • Auto Off time

Language setup The “Language setup” menu will show the number of channels according to the ‘Interpreter Channels’ settings. :

Those settings determine the behaviour of the Auto Off facility for the conference units.

-Channel 1Arabic ▲ -Channel 2: Bulgarian -Channel 3: Danish -Channel 4: Vietnamese ▼
  • Auto Off Values: {On,Off}

When set to On a conference unit will automatic turn of the microphone when the delegate stops talking. The time is determined by the ‘Auto Off time’ setting.

A channel entry is selected with the select keys 1-4 and the language for that channel can be chosen with the up/down buttons. If the value is changed is indicated with “>” to the left of the entry.

  • Auto Off time Values: {from 5 to 60 seconds in 5 second steps}

The new language selection is accepted with Enter button and cancelled with Menu button.

This setting is used to set the time from the delegate stops talking until the microphone turns off. The default value is 5 sec.

Booth Setup The “Booth Setup” menu will show a list op Booth (1 to 128).

When the system is set to VOX mode Auto Off settings are disabled.

The Interpretation Channels can now be assigned to the Booth. More Booths can be assigned the same channel.

Interpretation setup The “Interpretation setup” comprises the following entries:

As default Booth 1 is assigned Channel 1, Booth 2 assigned Channel 2 etc.

  • Interpreter Channels
  • Language setup
  • Booth Setup
  • Auto Floor
  • Interpreter Lock
  • Channel Display

Auto Floor When set to ON a language channel with no interpretation will have the Floor sound.

Values{On, Off}

Interpreter Channels This setting is used to set the number of Interpreter Channels in use.

Interpreter Lock The Interlock settings are used to setup the interlock between the Interpretation channels.

Values{0 to 31}

The settings are:

Page 17 of the Listen Technologies CU 6005 user manual — Back Panel Layout
Page 17 · click to enlarge
Page 17
  • Complete Lock With this setting an interpreter cannot switch on his microphone to any occupied interpreter channel.

Transmission of ambient noise rather than transmitting no sound at all is a desirable feature from listeners attending the meeting via headphones. The ambient noise indicates to the listeners, that there is no speaking activity going on, and this information is very nice to have, when interpreters are doing interpretation, and the speaker stops speaking.

This is the default setting.

  • No Lock With this setting an interpreter turning on his microphone to any occupied interpreter channel, will turn of the interpreter occupying the channel.

The setup menu has the following options:

  • Amb.Mic
  • Amb.Mic Level
  • Interlock Those settings are used to give various interlocks.

Amb.Mic When ‘enabled is selected, the Ambient Noise Microphone is active.

An interpreter turning on his microphone on an A- channel will interrupt another interpreter using his A channel

When the LineIn>Loudspk under Audio control is set to a value between -40dB and +20dB the microphone will be disabled. If the LineIn>Loudspk subsequently is set to Off, the microphone will stay disabled until enabled in Amb.Mic.

An interpreter turning on his microphone on an A- channel will interrupt another interpreter using his B channel, but will not interrupt an interpreter using his A channel.

Values{Enabled, Disabled}

Amb.Mic Level Adjust the level of the microphone to a level, which is suitable for the listener (Interpreter).

An interpreter turning on his microphone on an A- channel will interrupt another interpreter using his A or B channel.

Values{Off, -40, -39, …,18, 19, 20}

Channel Display This setting is used to switch the showing in the channel selectors displays in conference units between Language Abbreviation and Channel Number.

The user returns to the main menu by pressing either the Menu button or the Enter button.

Units info Selecting “Units info” from the Main menu, the Units info menu is entered:

Ambient microphone By choosing ‘Ambient Microphone’ from the main menu and parameters for an AM 6040 Ambient Noise microphone can be set up

  • Display Chain info
  • Display Unit types

Display Chain Info Selecting the first select button makes the system enter the Chain Information display. This display looks like this:

The purpose of an ambient noise microphone is to provide sound from a meeting room/conference hall, when there is no delegate/chairman using their microphones.

Chain A (f)2 Chain B (f): 2 Total (f/e): 4/5 f:found, e:expected

A interrupt A · A interrupt B · A interrupt A+B

Page 18 of the Listen Technologies CU 6005 user manual — Back Panel Layout
Page 18 · click to enlarge
Page 18

The Chain info menu displays information to the user about units connected to the CU. The information is divided into Chain A, Chain B and total. Found units are connected units, where the communication is maintained, and expected units comprises all units, which are defined in the ‘Configuration’.

The “Input mode” defines whether the ASCII communication via RS232/RS422 is protected by CRC check or not.

By protecting the communication (“Protected”), the risk of faulty communication via RS232/RS422 is minimized.

The risk of faults via RS232/RS422 is higher running the “Default” mode; however, the communication is possible from standard interfaces.

Menu button or Enter button leaves this screen.

Display Unit types Selecting the Display Unit types in the Units info menu displays the number of present units. The available units are:

The RS232 terminal interface emulator, Tera Term, does not feature the possibility of guarding the ASCII communication by CRC check.

  • Delegate units
  • Dual Mic. units
  • Chairman units
  • Voting units
  • Interpreter units
  • Audio Output units
  • Amb. Mic units
  • External Control
Values{Default, Protected}

Security setup The setup determines if ”Audio Scrambling” is activates or not.

Values{Off, On}

Default value is ‘off’. When switching to ‘on’, the CU has to be restarted. All units will automatically change to the scrambled mode.

For external control it is indicated by ‘ON’ or ‘OFF’ whether an external PC is connected and communicating (alive) via the RS232/RS422 connection to the CU.

The scrambling mode is used in high security places, when ears dropping cannot be accepted.

Configuration The “Configuration” menu comprises three menu items:

Menu button or Enter button leaves this screen.

RS232 setup The RS232 setup menu consists of two setup issues:

  • Load configuration
  • Save configuration
  • Delete configuration
  • RS232 baudrate
  • RS232 mode

Load configuration The “Load configuration” item brings the user to the Load configuration confirmation display:

RS232 baudrate The “RS232 baudrate” determines the bit rate of the communication between the CU and an external unit connected via the RS232 or RS422 connection.

Values{2400, 4800, 9600, 19200, 38400, 57600, 115200}

This will overwrite Current setup. Continue?

RS232 mode

Page 19 of the Listen Technologies CU 6005 user manual — Back Panel Layout
Page 19 · click to enlarge
Page 19

The load is aborted with the Menu button and accepted with the Enter button. In both cases, the menu system returns to the Main menu.

When switching the power to the CU 6010 OFF and then ON, the last saved setting will also be loaded.

Delete configuration The “Delete configuration” item brings the user to the Delete configuration confirmation display:

Save configuration If the “Save configuration” item is chosen this confirmation display is shown:

This will delete the configuration in flash. Continue?

This will overwrite the configuration in flash. Continue?

If the user accepts the deletion the progress display is shown:

If the user accepts the save the progress display is shown:

Deleting...

Saving...

The display is shown for a few seconds before the CU returns to the “Main menu”.

The display is shown for a few seconds before the CU returns to the “Main menu”.

License info menu Selecting the License info menu displays the available features enabled by the current license. The available features are:

Understanding “Save” and “Load” configuration When saving the configuration, the setting that has been done in the various menus in CU 6010, at the IS 6132 Interpreter Sets and at AO 6008 Audio Unit will be saved in the ‘Flash’ memory in the CU 6010.

  • Max. Conf. units
  • Max. Intp. Channels
  • VOX option
  • Voting option
  • Security option Menu button or Enter button leaves the screen.

Also the serial number and type of all units connected to the CU 6010 at the time of saving the configuration will be saved in the ‘Flash’ memory in the CU 6010.

Firmware info menu By choosing ‘Firmware info’ from the main menu information about the software version of the PowerPC and the DSP is shown as well as the Serial Number of the unit:

When switching on power to the CU 6010 at a later stage, then the units connected will be compared to the saved configuration. If some units are not present, they will be reported as ‘missing’

When ‘loading’ a configuration the last settings, which has been saved in the ‘Flash’ memory in the CU 6010 will be re-loaded to the CU 6010, to the IS 6132 Interpreter Sets and to the AO 6008 Audio Unit.

PPC5.3.86 DSP: 1.0.48 Serial No: 111.111.111
Page 20 of the Listen Technologies CU 6005 user manual — Normal Operation
Page 20 · click to enlarge
Page 20

The user returns to the main menu by pressing either the Menu button or the Enter button.

This screen is the standard screen showed at normal use. This screen is automatically shown if no buttons is pressed in 2 minutes. The function of this screen is explained in the section Audio Control menu.

Normal Operation

Powering up Switch on power at the CU 6010. After powering up, the display on the CU 6010 is showing the Start-up screen:

Use with SW 6000 Please refer to the SW 6000 manuals.

Schematics volume/gain settings The volume controls, which can be set on the CU 6010 user interface as described in the previous section are shown in the following schematic.

Setting of Loudspeaker volume 1. Set the Mic>Loudspk to 0dB

2. Turn up the Loudspk Volume to the level needed in the loudspeakers.

Digital Conference System 6000 DIS

Setting Line input level 1. Apply the signal to the Input connector

2. Turn up the input level on “LineInlevel Adj” until you can see the overflow indicator.

Registration Mode Unit registration Microphones disabled

-LineIn->Loudspk-17dB ▲ -LineIn->LineOut: 10dB >LineInLevel Adj:* -6dB -Loudspk volume: 3dB ▼

After initialising the following screens are displayed:

”*” Overflow indicator on line input

-Audio control ▲ -Delegate setup -Interpreter setup -Ambient Microphone ▼

3. Turn then the InputIn level down –8 dB to –12dB from the clipping level. Depending of the source connected, there might be different “overhead” needed. But normally 8-12 db is enough.
-Loudspk volume0dB ▲ -LineOut volume: 0dB -Mic->Loudspk: -9dB -Mic->LineOut: 2dB ▼
4. Turn up the Linein >Loudspk Volume to the level needed in the loudspeakers

The principle is that the level of signal from the Line Input is combined of two settings:

“LinelnLevel Adj” and “LineIn->Loudspk”.

Initializing · Please Wait

Page 21 of the Listen Technologies CU 6005 user manual — CU 6011 Central Unit
Page 21 · click to enlarge
Page 21

The LinelnLevel Adj has to be set as high as possible for maintaining the best S/N ration, but not too high to avoid clipping, whereas the LineIn-

>LoudSpk is used for setting the audio level needed in the loudspeakers.

CU 6010 Orignal Audio Volume Control

Listen Technologies CU 6005 — CU 6011 Central Unit diagram (page 21)
Fig. 8 · CU 6011 Central Unit

CU 6011 Central Unit

General description

The functionality of CU 6011 is identical to the CU 6010 Central Unit.

Page 22 of the Listen Technologies CU 6005 user manual — Features
Page 22 · click to enlarge
Page 22
  • Controls up to max. 500 Conference/Voting units. Controls of Interpreter Sets or other controllable units are as for CU 6010.

CU 6005 Central Unit

General description

  • Designed for up to 16 interpreted channels (instead of 31) and 8 open microphones

The functionality of CU 6005 is basically identical to the CU 6010 Central Unit; however the main parts are slightly different:

  • Built in Power Supply for app 50 Conference Units (instead of 200) or app. 150 Channel Selectors
  • Main processor board with Power PC and DSP
  • 2 outputs for connection to Delegate Units, Interpreter Units etc. (instead of 4)
  • DCS-LAN Network Control Card with 2 individual DCS-LAN outputs (instead of 4)
  • One Power supply (instead of 4)

Feature License

  • LCD display and buttons for system settings

The optional Feature Licenses for the CU 6005 are the same as for the CU 6010 Central Unit with the following differences:

  • 1 slot in the back panel for inserting modules e.g. AO 6004 (extra)
  • Conference Units, max.100 or max. 500. This count includes DM, CM, DV units. Dual Delegate units count for 2 units
  • Interpreter Channels, 1-8 channels or 1-16 channels

Features

The features of the CU 6005 are almost the same as for the CU 6010 Central Unit with the following differences:

Page 23 of the Listen Technologies CU 6005 user manual — Other
Page 23 · click to enlarge
Page 23

User Controls, indications & connectors

Front plate layout Identical to the CU 6010 Central Unit.

Front plate controls Identical to the CU 6010 Central Unit.

Back Panel Layout

Back Panel Connectors As the CU 6010 Central Unit with the following differences:

System settings

The same as for the CU 6010 Central Unit.

Chain A1 & A2 (no chain B1 & B2) RJ45 connector, 2 pieces

Normal Operation

The same as for the CU 6010 Central Unit.

DCS-LAN connectors for connection to DM/CM 6xxx, IS 6132, CS 6032, EX 6010, AO 6004/6008 etc. For connecting Interpreter Sets for up to 16 languages.

Other

Slot (extra) Slot for inserting modules in the back panel, e.g. AO 6004. Slot dimensions (W x H x D) 180 x 38 x 120 mm.

Page 24 of the Listen Technologies CU 6005 user manual — Built into 19” Racks
Page 24 · click to enlarge
Page 24

System Setup

General guidelines

Connect the CU 6005/6010/6011 to the various DCS 6000 units using Cat5 or Cat5e FTP or STP screened cables.

between the units. Please consult the next section ‘Maximum number of units to be connected’.

The operation of the DCS 6000 units is found in the User Manual for the specific units.

  • The maximum number of languages configured on chain A (A1 or A2) or B (B1 or B2) is 16. If more languages are required, Interpreter sets for those languages have to be divided between both chains (A and B) – this is only applicable for the CU 6010/6011. Normally the languages are supposed to be divided equally on chains A (A1 or A2) and B (B1 or B2).

Please observe the following guidelines:

  • Maximum cable length in one chain is 200 m (before repeating). This includes interconnection cables between the units. The max. usable cable length depends on the units connected and length of feeding cables etc.
  • Maximum cable length in one chain when using repeaters is 650 m.
  • If the last unit in one chain is a CS 6032 Channel Selector, this unit has to be terminated with an external termination, as the CS 6032 does not have an internal automatic termination.
  • Although the DCS-LAN Network Output connectors (CU 6005: A1 plus A2, CU 6010/6011: A1, A2, B1 or B2) have a 125W supply, this 125W power is not all available with long cables, as there will be a power drop in the feeding cable from the CU 6005/6010/6011 to the units connected. If the feeding cables are short and the cables between the units are short, more units can be connected than if the feeding cable is long and/or the cables are long

It is desirable that the square of the feeding cables especially but also the interconnection cables are as big as possible to minimize the voltage drop in the cables. Cat 5/Cat5E cables are delivered in various gauges:

The following table is showing the Diameter/square for various AWG types:

Type Diameter Square AWG22 0.64 mm 0.32 mm2

AWG23/1 0.57 mm 0.25 mm2

AWG24 0.53 mm 0.22 mm2

AWG26 0.42 mm 0.14 mm2

Built into 19” Racks

The unit has a built-in fan taking air in at the right side of the unit and blowing the hot air out at the right side. That allows units in 19” racks to be

stacked close with other units without extra room for cooling air between them. Please check that the other units will allow this.

Page 25 of the Listen Technologies CU 6005 user manual — CM/DM 60x0P Chairman/Delegate Units & JB 6002 Junction Box – CU 6010/6011
Page 25 · click to enlarge
Page 25

Maximum number of units to be connected

The following table shows the maximum number of units, which can be connected to each of the four outputs (A1, A2, B1 or B2) on a CU 6010/6011

Central Unit or on each output on an EX 6010 Extension Unit or on the output of a PS 6000..

Listen Technologies CU 6005 — Maximum number of units to be connected diagram (page 25)
Fig. 9 · Maximum number of units to be connected

10 m 1 m 51 m 42 30 m 1 m 67 m 38 50 m 1 m 83 m 34 100 m 1 m 122 m 23 150 m 1 m 165 m 16 10 m 2 m 88 m 40 30 m 2 m 98 m 35 50 m 2 m 108 m 30 100 m 2 m 140 m 21 150 m 2 m 178 m 15

The following table shows the maximum number of units, which can be connected to the two outputs (A1 and A2) simultaneously on a CU 6005 in total

If only one chain is used the information in the above table must be used.

Listen Technologies CU 6005 — Maximum number of units to be connected diagram (page 25)
Fig. 10 · Maximum number of units to be connected

10 m 1 m 2x32 m 2x23 30 m 1 m 2x51 m 2x22 50 m 1 m 2x70 m 2x21 100 m 1 m 2x117 m 2x18 150 m 1 m 2x164 m 2x15 10 m 2 m 2x54 m 2x23 30 m 2 m 2x72 m 2x22 50 m 2 m 2x88 m 2x20 100 m 2 m 2x132 m 2x17 150 m 2 m 2x176 m 2x14

CM/DM 60x0P Chairman/Delegate Units & JB 6002 Junction Box – CU 6010/6011

This configuration shows two CM/DM 60x0P Delegate/Chairman Units connected to one JB 6002 Junction Box with 3m cables between each JB 6002.

Maximum 5 m cable from JB 6002 to CM/DM 60x0 and maximum one CM/DM 60x0 on each output of JB 6002.

Page 26 of the Listen Technologies CU 6005 user manual — CM/DM 6060F/6510F Chairman/Delegate Units – CU 6010/6011
Page 26 · click to enlarge
Page 26
Listen Technologies CU 6005 — CM/DM 6060F/6510F Chairman/Delegate Units – CU 6010/6011 diagram (page 26)
Fig. 11 · CM/DM 6060F/6510F Chairman/Delegate Units – CU 6010/…

10 m 3 m 61 m 18 36 30 m 3 m 75 m 16 32 50 m 3 m 89 m 14 28 100 m 3 m 127 m 10 20 150 m 3 m 168 m 7 14

CM/DM 6060F/6510F Chairman/Delegate Units – CU 6010/6011

The following table shows the maximum number of units, which can be connected to each of the four outputs (A1, A2, B1 or B2) on a CU 6010/6011

Central Unit or on each output on an EX 6010 Extension Unit or on the output of a PS 6000.

Listen Technologies CU 6005 — CM/DM 6060F/6510F Chairman/Delegate Units – CU 6010/6011 diagram (page 26)
Fig. 12 · CM/DM 6060F/6510F Chairman/Delegate Units – CU 6010/…

Total cable length Max. number of CM/DM 60x0 pr output

10 m 1 m 39 m 30 30 m 1 m 56 m 27 50 m 1 m 73 m 24 100 m 1 m 115 m 16 150 m 1 m 160 m 11 10 m 2 m 64 m 28 30 m 2 m 78 m 25 50 m 2 m 94 m 23 100 m 2 m 130 m 16 150 m 2 m 170 m 11

The following table shows the maximum number of units, which can be connected to each of the four outputs (A1, A2, B1 or B2) on a CU 6010/6011

Central Unit or on each output on an EX 6010 Extension Unit or on the output of a PS 6000.

Listen Technologies CU 6005 — CM/DM 6060F/6510F Chairman/Delegate Units – CU 6010/6011 diagram (page 26)
Fig. 13 · CM/DM 6060F/6510F Chairman/Delegate Units – CU 6010/…

10 m 1 m 35 m 27 30 m 1 m 53 m 24 50 m 1 m 70 m 21 100 m 1 m 113 m 14 150 m 1 m 159 m 10 10 m 2 m 58 m 25 30 m 2 m 72 m 22 50 m 2 m 88 m 20 100 m 2 m 126 m 14 150 m 2 m 166 m 9

Page 27 of the Listen Technologies CU 6005 user manual — DC 6990P Conference Units – CU 6005
Page 27 · click to enlarge
Page 27

DC 6990P Conference Units – CU 6010/6011

The following table shows the maximum number of units, which can be connected to each of the four outputs (A1, A2, B1 or B2) on a CU 6010/6011

Central Unit or on each output on an EX 6010 Extension Unit or on the output of a PS 6000.

Listen Technologies CU 6005 — DC 6990P Conference Units – CU 6010/6011 diagram (page 27)
Fig. 14 · DC 6990P Conference Units – CU 6010/6011

Total cable length Max. number of DC 6990P pr output

10 m 1 m 35 m 26 30 m 1 m 53 m 24 50 m 1 m 70 m 21 100 m 1 m 112 m 13 150 m 1 m 158 m 9 10 m 2 m 56 m 25 30 m 2 m 72 m 22 50 m 2 m 90 m 19 100 m 2 m 124 m 13 150 m 2 m 166 m 9

DC 6990P Conference Units – CU 6005

The following table shows the maximum number of units, which can be connected to the two outputs (A1 and A2) simultaneously on a CU 6005 in total

If only one chain is used the information in the above table must be used.

Listen Technologies CU 6005 — DC 6990P Conference Units – CU 6005 diagram (page 27)
Fig. 15 · DC 6990P Conference Units – CU 6005

Total cable length Max. number of DC 6990 for both outputs

10 m 1 m 2x34 m 2x15 30 m 1 m 2x43 m 2x14 50 m 1 m 2x62 m 2x13 100 m 1 m 2x110 m 2x11 150 m 1 m 2x158 m 2x9 10 m 2 m 2x36 m 2x14 30 m 2 m 2x54 m 2x13 50 m 2 m 2x90 m 2x12 100 m 2 m 2x118 m 2x10 150 m 2 m 2x164 m 2x8

Page 28 of the Listen Technologies CU 6005 user manual — IS 6132P Interpreter Units – CU 6010/6011
Page 28 · click to enlarge
Page 28

MU 6040C/D and MU 6042D without connected loudspeaker – CU 6010/6011

This table shows the maximum number of MU 6040 Microphone Units, which can be connected to each of the four outputs (A1, A2, B1 or B2) on a CU 6010/6011 Central Unit or on each output on an EX 6010 Extension Unit or on the output of a PS 6000.

The numbers are valid with no audio in loudspeaker (no loudspeaker connected to each unit). If loudspeakers are used, then use the figures for CM/DM 60x0P above.

Listen Technologies CU 6005 — MU 6040C/D and MU 6042D without connected loudspeaker – CU 6010/6011 diagram (page 28)
Fig. 16 · MU 6040C/D and MU 6042D without connected loudspeake…

10 m 2 m 168 m 80 30 m 2 m 178 m 75 50 m 2 m 188 m 70 100 m 2 m 200 m 51 150 m 2 m 200 m 26 100 m 1 m 151 m 52 150 m 1 m 191 m 42

IS 6132P Interpreter Units – CU 6010/6011

The tables below shows the maximum number of IS 6132P Interpreter Sets, which can be connected to each of the four outputs (A1, A2, B1 or B2) on a CU 6010/6011 Central Unit or on each output on an EX 6010 Extension Unit or on the output of a PS 6000.

If loudspeakers are used, then use the figures for CM/DM 60x0P above.

The numbers are with no audio in loudspeaker (no loudspeaker connected to each unit).

Listen Technologies CU 6005 — IS 6132P Interpreter Units – CU 6010/6011 diagram (page 28)
Fig. 17 · IS 6132P Interpreter Units – CU 6010/6011

10m 2 m 54 x x 30m 2 m 49 57 60 50m 2 m 44 51 x 100m 2 m 35 40 x 150m 2 m 25 30 x

Page 29 of the Listen Technologies CU 6005 user manual — CS 6032F Channel Selector w/back light on – CU 6010/6011
Page 29 · click to enlarge
Page 29
Listen Technologies CU 6005 — IS 6132P w/JB 6004 and LS 6032 – CU 6010/6011 diagram (page 29)
Fig. 18 · IS 6132P w/JB 6004 and LS 6032 – CU 6010/6011

IS 6132P w/JB 6004 and LS 6032 – CU 6010/6011

10 m 5 m 19 4 0 10 m 5 m 12 4 4 30 m 5 m 17 4 0 30 m 5 m 10 4 4 50 m 5 m 15 4 0 50 m 5 m 9 4 4 100 m 5 m 11 4 0 100 m 5 m 7 4 4 150 m 5 m 8 4 0 150 m 5 m 5 4 4

CS 6032F Channel Selector w/back light on – CU 6010/6011

The tables below shows the maximum number of CS 6032F Channel Selectors, which can be connected to each of the four outputs (A1, A2, B1 or

B2) on a CU 6010/6011 Central Unit or on each output on an EX 6010 Extension Unit or on the output of a PS 6000.

Listen Technologies CU 6005 — CS 6032F Channel Selector w/back light on – CU 6010/6011 diagram (page 29)
Fig. 19 · CS 6032F Channel Selector w/back light on – CU 6010/…

Total cable length Max. number of CS 6032 pr

30 m 1 m 139 m 110 50 m 1 m 144 m 95 100 m 1 m 184 m 85 150 m 1 m 200 m 51 10 m 2 m 200 m 96 30 m 2 m 200 m 86 50 m 2 m 200 m 76 100 m 2 m 200 m 51 150 m 2 m 200 m 26

Page 30 of the Listen Technologies CU 6005 user manual — Small conference microphone system with CU 6010
Page 30 · click to enlarge
Page 30

Typical schematics

The following schematics are showing various configurations:

Small conference microphone system with CU 6005

Listen Technologies CU 6005 — Small conference microphone system with CU 6005 diagram (page 30)
Fig. 20 · Small conference microphone system with CU 6005

Small conference microphone system with CU 6010

Listen Technologies CU 6005 — Small conference microphone system with CU 6010 diagram (page 30)
Fig. 21 · Small conference microphone system with CU 6010
Page 31 of the Listen Technologies CU 6005 user manual — Typical schematics
Page 31 · click to enlarge
Page 31
Listen Technologies CU 6005 — Typical schematics diagram (page 31)
Fig. 22 · Typical schematics
Listen Technologies CU 6005 — Typical schematics diagram (page 31)
Fig. 23 · Typical schematics
Page 32 of the Listen Technologies CU 6005 user manual — Microphone conference system with 3+1 ch. interpretation & IR, CU 6005
Page 32 · click to enlarge
Page 32
Listen Technologies CU 6005 — Microphone conference system with 3+1 ch. interpretation & IR, CU 6005 diagram (page 32)
Fig. 24 · Microphone conference system with 3+1 ch. interpreta…

Microphone conference system with 3+1 ch. interpretation & IR, CU 6005

Microphone conference system with 15+1 ch. interpretation & IR, CU 6010

Listen Technologies CU 6005 — Microphone conference system with 3+1 ch. interpretation & IR, CU 6005 diagram (page 32)
Fig. 25 · Microphone conference system with 3+1 ch. interpreta…
Page 33 of the Listen Technologies CU 6005 user manual — Various configurations with RP 6004 Repeater and PS 6000 Power Supply
Page 33 · click to enlarge
Page 33
Listen Technologies CU 6005 — Various configurations with RP 6004 Repeater and PS 6000 Power Supply diagram (page 33)
Fig. 26 · Various configurations with RP 6004 Repeater and PS…

Various configurations with RP 6004 Repeater and PS 6000 Power Supply

Page 34 of the Listen Technologies CU 6005 user manual — Small system with SW 6000 Conference Management Software
Page 34 · click to enlarge
Page 34

Small system with SW 6000 Conference Management Software

Listen Technologies CU 6005 — Small system with SW 6000 Conference Management Software diagram (page 34)
Fig. 27 · Small system with SW 6000 Conference Management Soft…
Page 35 of the Listen Technologies CU 6005 user manual — Large system with SW 6000 Conference Management Software
Page 35 · click to enlarge
Page 35

Large system with SW 6000 Conference Management Software

Listen Technologies CU 6005 — Large system with SW 6000 Conference Management Software diagram (page 35)
Fig. 28 · Large system with SW 6000 Conference Management Soft…
Page 36 of the Listen Technologies CU 6005 user manual — RS 422 Serial connection
Page 36 · click to enlarge
Page 36
Listen Technologies CU 6005 — RS 232 Serial connection diagram (page 36)
Fig. 29 · RS 232 Serial connection

CAT6 can thus only be used for longer cable draws terminating in wall outlets or patch panels.

CAT5 The DCS 6000 system uses CAT5, CAT5e or CAT6 FTP or STP cables with screened RJ45 connectors.

RS 232 Serial connection

Listen Technologies CU 6005 — RS 232 Serial connection diagram (page 36)
Fig. 30 · RS 232 Serial connection

1 * 1 DCD 2 TxD 2 RxD 3 RxD 3 TxD 4 * 4 DTR 5 0V 5 0V 6 * 6 DSR 7 RTS 7 CTS 8 CTS 8 RTS 9 9 RI Connect all pins in the connectors: Pin 1 to Pin 1, Pin 2 to Pin 2, Pin 3 to Pin 3 and so on.

EIA 568-B wiring shall be used.

It is important to use only FTP or STP (screened) cables and screened RJ45 connectors and not UTP cable, which is unscreened.

How to wire a CAT5 (EIA 568-B) Cable:

Listen Technologies CU 6005 — RS 232 Serial connection diagram (page 36)
Fig. 31 · RS 232 Serial connection

1 In-going + ORG/WHT ORG/WHT 2 In-going - ORG ORG 3 +48V GRN/WHT GRN/WHT 4 0V BLU BLU 5 0V BLU/WHT BLU/WHT 6 +48V GRN GRN 7 Outgoing - BRN/WHT BRN/WHT 8 Outgoing + BRN BRN

* Pin 1, 4 and 6 are connected together inside the CU 6005/6010/6011.

RS 422 Serial connection

Listen Technologies CU 6005 — RS 422 Serial connection diagram (page 36)
Fig. 32 · RS 422 Serial connection

1 RXD+(B) 1 2 RXD-(A) 2 3 TXD-(A) 3 4 TXD+(B) 4 5 0V 5 6 RTS-(A) 6 7 RTS+(B) 7 8 CTS+(B) 8 9 CTS-(A) 9

pairs are connected as follows:

Pair 1Pin 1 & 2
Pair 2Pin 3 & 6
Pair 3Pin 4 & 5
Pair 4Pin 7 & 8

The phase of the pairs must be correct and

the wiring spec. as stated in CAT5 (EIA 568-B) have to be followed.

the RS422. Please consult the manual for the RS422 card in your PC or control system.

Page 37 of the Listen Technologies CU 6005 user manual — Analog Audio, Line Input (XLR3 female)
Page 37 · click to enlarge
Page 37

Accessories (not supplied)

Please observe that either the RS232 Serial Connection or the RS422 Serial Connection can be used. It is not possible to use both at the same time.

Cat 5 Connection Cables (AWG24)

EC 6000-0.5 Connection Cable 0.5 m 10 03 12500

EC 6000-01 Connection Cable 1 m 10 03 13101

Analog Audio, Line output (XLR3 male)

EC 6000-02 Connection Cable 2 m 10 03 13201

Pin Signal Cable type

EC 6000-05 Connection Cable 5 m 10 03 13501

1 Ground 2 In phase signal 3 Out phase signal

DIS type #2914 or 2 x 0.25 mm2 shielded.

EC 6000-10 Connection Cable 10 m 10 03 14102

EC 6000-20 Connection Cable 20 m 10 03 14202

EC 6000-50 Connection Cable 50 m 10 03 14502

Analog Audio, Line Input (XLR3 female)

Pin Signal Cable type

EC 4010-05 Connection Cable 1 m 15 51 05563

DIS type #2914 or 2 x 0.25 mm2 shielded.

1 Ground 2 In phase signal 3 Out phase signal

EC 4010-05 Connection Cable 2 m 15 51 05564

EC 4010-05 Connection Cable 5 m 15 51 05565

EC 4010-05 Connection Cable 10 m 15 51 05566

RS232 cables

Page 38 of the Listen Technologies CU 6005 user manual — .................................................................... 31 (CU 6010/6011)
Page 38 · click to enlarge
Page 38

Technical specifications

Digital Section

Connectors

Sound quality 24 bit audio @ 32 kHz sampling frequency

DCS 6000 network chain (DCS-LAN) RJ45

Analogue Section

2 pieces (CU 6005)

Floor output signal type electronically balanced

4 pieces (CU 6010/6011)

Nominal output level -8 dBm at nominal input

Maximum number of units to be connected to the two outputs in total on a CU 6005 or to each chain of the four outputs on a CU 6010/6011:

Max. output level 3.5V RMS ∼ +13 dBm

Line input signal type electronically balanced

MU 6040 Microphone Units up to 80 pieces

Nominal input level (adjustable)

DM/CM 60x0P Delegate/Chairman Unit ...up to 42 pieces

+6 to -30 dBm (1.55 V RMS to 25 V RMS)

IS 6132P Interpreter Set up to 54 pieces

Max. input level +30 dBm (25V RMS)

CS 6032F Channel Selector up to 110 pieces

Line input impedance 25-50 kohm

The actual maximum number of units depends on the length of the feeding cable and interconnection cables

Frequency response 50-15kHz

Line output XLR3 male connector

Signal to noise ratio.................................................. >85 dBA
Total harmonic distortion............................................ < 0.1%

Line input XLR3 female connector

General

RS 232 (with hardware handshake) D-Sub 9 female

RS 422 (with hardware handshake D-Sub 9 male

Power consumption max. 150W (CU 6005)

either the RS232 or the RS422 can be used

max. 600W (CU 6010/6011)

In-rush current max. 30A@115V or max. 60A@230V

System performance with CU 6005/6010/6011 as central unit

Mains voltage....................................... 100 - 240V, 50 - 60Hz

Max. number of conference units 3800 (CU 6010/6011)

Supply voltage for units

Max. number of conference units 500 (CU 6005)

(forA1 plus A2) .................................... 48V/125W (CU 6005)

Max. number of units (excl. CS) 4000

(for eachA1, A2, B1, B2)............. 48V/125W (CU 6010/6011)

Max. number of IS 6xxx in one booth 32

Temperature to guarantee specified performance

Max. number of IS 6xxx 150

5 Deg C. to 40 Deg C. (35 to 80% humidity)

Max. number of AO 6004/6008 20

Storage temp -20 Deg C. to 60 Deg C. (10 to 80% humidity)

Max. number of CS 6032 practically unlimited

Weight 5.7 kg (CU 6005)

Max. number of languages 16 (CU 6005)

6.2 kg (CU 6010/6011)

31 (CU 6010/6011)

Dimensions (W x H x D) 425 (483) x 87 x 317 (357) mm

Dimensions in bracket are including 19” brackets

Max number of open microphones 8

Slot dimensions (W x H x D) 180 x 38 x 120 mm (CU 6005)

The DCS 6000 system conforms to all relevant standards - e.g. IEC 914, ISO 4043, and ISO 2603

Accessories supplied User manual

Mains cable

5 pieces termination plugs

Specifications are subject to change without notice.

Page 39 of the Listen Technologies CU 6005 user manual — Technical specifications
Page 39 · click to enlarge
Page 39
Page 39 of the Listen Technologies CU 6005 user manual — Technical specifications

Ask about the Listen Technologies CU 6005

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Listen Technologies CU 6005

Be the first to ask — other owners or our team will answer.

Original document

Listen Technologies CU 6005 manual PDF

39 pages·3 MB·Stereo Receiver·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…