The equipment must be connected to earth
The equipment has been tested and found to comply with the limits of the following standards for digital devices:
Allow adequate air circulation to prevent internal heat built-up. Do not place the unit on a surface (rugs, blankets, etc.) that may block the ventilation holes.
Do not install the unit in a location near heat sources such as radiators or air ducts, or in a place exposed to direct sunlight, excessive dust or humidity, mechanical vibration or shock.
This device complies with part 15 of the FCC rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
To avoid moisture condensations do not install the unit where the temperature may rise rapidly.
When installing the unit inside a 19” rack, observe that the rack is properly ventilated. The maximum allowed temperature inside the rack is 40 °C.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in residential, commercial or light industrial environments. The equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the user manual it may cause harmful interference to radio communications.
To keep the cabinet in its original condition, periodically clean it with a soft cloth. Stubborn stains may be removed with a cloth lightly dampened with a mild detergent solution. Never use organic solvents such as thinners or abrasive cleaners since these will damage the cabinet.
You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.
Save the original shipping cardboard box and packing material; they will become handy if you ever have to ship the unit. For maximum protection, re-pack the unit as originally packed from the factory.
Check that the voltage of your local power supply is within the operating voltage of the unit (100-240V AC). If a voltage conversion is required, consult your DIS dealer or qualified personnel.
The unit is minimum covered by 12 months warranty against defects in materials or work- manship.
Should any liquid or solid object fall into the cabinet, unplug the unit and have it checked by qualified personnel before operating it further.
Set the Power switch to OFF if it is not used for several days.

The DCS 6000 system has the following main features:
RS232/RS422 connection on CU 6005/6010 for external operation of the system of a PC or control system such as AMX or Crestron
The SW 6000 is an optional software package, which expands the functionality of the DCS 6000 system. The software runs on standard computer technology (Standard PC with Windows 2000 or XP).
Main features of the SW 6000 are:

Conference equipment and channel selectors
The CU 6005/6010 Central Unit supports all available units in the DCS 6000 series:
CS 6032FV/H Channel Selector (flush mounted) DM 6010P Conference Unit (portable) DM 6060P Conference Unit (portable) with one built-in channel selector CM/DM 6070P Conference Unit (portable) with two built-in channel selectors CM/DM 6090P Conference Unit (portable) with two built-in channel selectors and XLR microphone connector CM/DM 6060F Conference Unit (flush mounted)
Central equipment etc.
EX 6010 Extension Unit PS 6000 Power Supply AO 6004 Audio Output box AO 6008 Audio Output box RP 6004 Repeater for four chains JB 6002 Junction Box with 2 outputs JB 6004 Junction Box with 4 outputs
with one built-in channel selectors CM/DM 6510F Conference Unit (flush mounted) with Chip-card and 3 voting buttons CM/DM 6560F Conference Unit (flush mounted) with one built-in channel selector, Chip-card and 3 voting buttons MU 6040C/D Microphone Unit for use with customised front plate with Loudspeaker, Microphone and Buttons. Available in Delegate (D) and Chairman (C) version MU 6042D Dual Microphone Unit for use with FD/FC front plate with Loudspeaker, Microphone and two delegate Buttons AM 6040 Ambient Noise Microphone
IS 6132P Interpreter Set LS 6132P Interpreter Loudspeaker
DV 6501F Voting Unit
Interpreter equipment

General description
The PS 6000 Power Supply provides additional Power for the DCS 6000 system.
One CU 6005/6010 Central Unit is needed in each DCS 6000 system; however for expansion of the system the PS 6000 Power Supply is suitable. The PS 6000 consists of:
The PS 6000 Power Supply features the following connectors:
Power connector Connection for main power.
Loop through connectors RJ45 connector, 2 pieces
The main features of the PS 6000 Power Supply are:
DCS-LAN connectors used for connection to the CU 6005/6010 and for connection to other units with DCS-LAN connectors such as more PS 6000.
Power LED Those green LED light up when Power is available on the connector next to the LED.
There are no settings to be done on the PS 6000 Power Supply.
And the PS 6000 is NOT a repeater, which means that the maximum cable length in a chain (which without repeater is 200 m) has to be calculated from the last unit with repeater functionality (typically a CU 6005/6010, EX 6010 or RP 6004) to the last unit connected to the PS 6000.
However it is important to observe, that the unit is only adding power to one of the chains on the CU 6005/6010 Central Unit.
And as so, the specification, which applies the two chain outputs on the CU 6005 Central Unit and to each of the chain outputs on the CU 6010 Central Unit, does also apply to the output on the PS 6000.
This includes interconnection cables between the units.

The PS 6000 can be inserted at any point in a DCS 6000 chain, where extra power is needed. The PS 6000 is used, when extra power is needed typically, where long feeding cables are needed.
A typical application is to place a PS 6000 in the first Interpreter Booth to compensate for a long feeding cable.
The following schematic shows various ways in how to use the PS 6000 Power Supply:



Connect the PS 6000 to the various DCS 6000 units using Cat5 or Cat5e FTP or STP screened cables. Please observe the following guidelines:
between the units are short, more units can be connected than if the feeding cable is long and/or the cables are long between the units. Please consult the next section (Max. Number of units to be connected)
It is desirable that the square of the feeding cables especially, but also the interconnection cables are as big as possible to minimize the voltage drop in the cables. Cat 5/Cat5E cables are delivered in various gauges:
The following table is showing the Diameter/square for various AWG types
Type Diameter Square AWG22 0.64 mm 0.32 mm2
AWG23/1 0.57 mm 0.25 mm2
AWG24 0.53 mm 0.22 mm2
AWG26 0.42 mm 0.14 mm2

The following tables show the maximum number of units, which can be connected to the two outputs (A1 or A2) on a CU 6005 Central Unit in total or to each of the four outputs (A1, A2, B1 or B2) on a
CU 6010 Central Unit or to each output on an EX 6010 Extension Unit or to the output of a PS 6000 Power Supply.

This configuration shows two CM/DM 60x0 Delegate/Chairman Units connected to one JB 6002 Junction Box with 3m cables between each JB
6002. Maximum 5 m cable from JB 6002 to CM/DM 60x0 and max. one CM/DM 60x0 on each output of JB 6002.


The following tables show the maximum number of units, which can be connected to the two outputs (A1 or A2) on a CU 6005 Central Unit in total or to each of the four outputs (A1, A2, B1 or B2) on a
CU 6010 Central Unit or to each output on an EX 6010 Extension Unit or to the output of a PS 6000 Power Supply.


This table shows the maximum number of MU 6040 Microphone Units, which can be connected. The numbers are with no audio in loudspeaker (no
loudspeaker connected to each unit). If loudspeakers are used, then use the figures for CM/DM 60x0 above.

Numbers in (‘) are the number of units, which could have been connected CU/EX, but where the total
number of units has been lowered due to the restriction of the maximum length of cable (200 m).
This table shows the maximum number of IS 6132P Interpreter Sets, which can be connected. The numbers are with no audio in loudspeaker (no loudspeaker connected to each unit).
If loudspeakers are used, then use the figures for CM/DM 60x0 above.

10m 2 m 54 x x 30m 2 m 49 57 60 50m 2 m 44 51 x 100m 2 m 35 40 x 150m 2 m 25 30 x


10 m 5 m 19 4 0 10 m 5 m 12 4 4 30 m 5 m 17 4 0 30 m 5 m 10 4 4 50 m 5 m 15 4 0 50 m 5 m 9 4 4 100 m 5 m 11 4 0 100 m 5 m 7 4 4 150 m 5 m 8 4 0 150 m 5 m 5 4 4
Total cable length Max. number of CS 6032 pr
30 m 1 m 139 m 110 50 m 1 m 144 m 95 100 m 1 m 184 m 85 150 m 1 m 200 m 51 (67’) 10 m 2 m 200 m 96 30 m 2 m 200 m 86 (90’) 50 m 2 m 200 m 76 (85’) 100 m 2 m 200 m 51 (70’) 150 m 2 m 200 m 26 (60’) Numbers in (‘) are the number of units, which could have been connected to the CU/EX, but where the
total number of units has been lowered due to the restriction of the maximum length of cable (200 m).


CAT5 The DCS 6000 system uses CAT5, CAT5e or CAT6 FTP or STP cables with screened RJ45 connectors.
The phase of the pairs must be correct and the wiring spec. as stated in CAT5 (EIA 568-B) have to be followed.
EIA 568-B wiring shall be used.
It is important to use only FTP or STP (screened) cables and screened RJ45 connectors and not UTP cable, which is unscreened.
How to wire a CAT5 (EIA 568-B) Cable:
CAT6 can thus only be used for longer cable draws terminating in wall outlets or patch panels.

1 In-going + ORG/WHT ORG/WHT 2 In-going - ORG ORG 3 +48V GRN/WHT GRN/WHT 4 0V BLU BLU 5 0V BLU/WHT BLU/WHT 6 +48V GRN GRN 7 Outgoing - BRN/WHT BRN/WHT 8 Outgoing + BRN BRN
Cat 5e Connection Cables (AWG24)
EC 6000-..5 Connection Cable 0.5 m 10 03 12500
EC 6000-01 Connection Cable 1 m 10 03 13101
EC 6000-02 Connection Cable 2 m 10 03 13201
EC 6000-05 Connection Cable 5 m 10 03 13501
EC 6000-10 Connection Cable 10 m 10 03 14102
EC 6000-20 Connection Cable 20 m 10 03 14202
pairs are connected as follows:
EC 6000-50 Connection Cable 50 m 10 03 14502
General
Weight 1 kg
Power consumption max. 150W
Dimensions (W x H x D) 100 (125) x 50 x 205 mm
Dimensions in bracket are including the fixing bracket
Supply voltage for units 48V/125W
Accessories supplied Main cable
Temperature to guarantee specified performance
DCS-LAN loop through 2 pieces RJ45
5 Deg C. to 40 Deg C. (35 to 80% humidity)
Specifications are subject to change without notice.
-20 Deg C. to 60 Deg C. (10 to 80% humidity)
Connectors · Storage temperature