EN
Listen Technologies logo
Official user manual

Listen Technologies PS 6000

14 pages·123 KB·Power Supply·PDF·ENDEFRITNLJA
Listen Technologies PS 6000
Table of Contents 30 sections DCS 6000 · User Manual · Digital Conference System · PS 6000 Power Supply · … ShowHide
Page 1 of the Listen Technologies PS 6000 user manual — Danish Interpretation Systems DIS
Page 1 · click to enlarge
Page 1

DCS 6000

Listen Technologies PS 6000 — DCS 6000 diagram (page 1)
Fig. 1

User Manual

Digital Conference System

Listen Technologies PS 6000 — Digital Conference System diagram (page 1)
Fig. 2 · Digital Conference System

PS 6000 Power Supply

Danish Interpretation Systems DIS

Page 2 of the Listen Technologies PS 6000 user manual — DCS 6000
Page 2 · click to enlarge
Page 2

Copyright © 2007 DIS PS6000 REV B.DOC 21-05-2007

No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher.

Page 3 of the Listen Technologies PS 6000 user manual — DCS 6000
Page 3 · click to enlarge
Page 3
Page 3 of the Listen Technologies PS 6000 user manual — DCS 6000
Page 4 of the Listen Technologies PS 6000 user manual — Warranty
Page 4 · click to enlarge
Page 4

Important

Compliancy

The equipment must be connected to earth

Installation precautions

The equipment has been tested and found to comply with the limits of the following standards for digital devices:

Allow adequate air circulation to prevent internal heat built-up. Do not place the unit on a surface (rugs, blankets, etc.) that may block the ventilation holes.

  • EN55103-1 (Emission)
  • EN55103-2 (Immunity
  • EN60065 safety
  • UL6500 safety
  • FCC rules part 15, class A (Emission)

Do not install the unit in a location near heat sources such as radiators or air ducts, or in a place exposed to direct sunlight, excessive dust or humidity, mechanical vibration or shock.

This device complies with part 15 of the FCC rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

To avoid moisture condensations do not install the unit where the temperature may rise rapidly.

When installing the unit inside a 19” rack, observe that the rack is properly ventilated. The maximum allowed temperature inside the rack is 40 °C.

These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in residential, commercial or light industrial environments. The equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the user manual it may cause harmful interference to radio communications.

Cleaning & Repacking

To keep the cabinet in its original condition, periodically clean it with a soft cloth. Stubborn stains may be removed with a cloth lightly dampened with a mild detergent solution. Never use organic solvents such as thinners or abrasive cleaners since these will damage the cabinet.

You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.

Save the original shipping cardboard box and packing material; they will become handy if you ever have to ship the unit. For maximum protection, re-pack the unit as originally packed from the factory.

Safety

Check that the voltage of your local power supply is within the operating voltage of the unit (100-240V AC). If a voltage conversion is required, consult your DIS dealer or qualified personnel.

Warranty

The unit is minimum covered by 12 months warranty against defects in materials or work- manship.

Should any liquid or solid object fall into the cabinet, unplug the unit and have it checked by qualified personnel before operating it further.

Set the Power switch to OFF if it is not used for several days.

Page 5 of the Listen Technologies PS 6000 user manual — Features
Page 5 · click to enlarge
Page 5

Description of the DCS 6000 system

Features

  • Added functionality and comprehensive features provided by SW 6000 software package running on PC

The DCS 6000 system has the following main features:

RS232/RS422 connection on CU 6005/6010 for external operation of the system of a PC or control system such as AMX or Crestron

  • Fully digital
  • Excellent sound quality

The SW 6000 is an optional software package, which expands the functionality of the DCS 6000 system. The software runs on standard computer technology (Standard PC with Windows 2000 or XP).

  • “State of the Art” fully digital integrated interpretation, discussion and voting system offering interpretation, language distribution, conference microphone and voting facilities with attendance check with Chip Card ™.

Main features of the SW 6000 are:

  • New, unique digital DATA and AUDIO bus.
  • Microphone management
  • 39 incoming channels (8 floor channels + 31 interpreted channels) and one Line input.
  • Mimic panel operation
  • Interpretation management
  • 34 distributed channels (3 x floor + 31 interpreted channels)
  • Voting management
  • The Delegate and Interpreter units are powered and controlled by the CU 6005 Central Unit, which drives up to app. 50 units on 2 chains or by the CU 6010 Central Unit, which drives up to app. 200 units on 4 chains.
  • Message handling
  • Agenda handling
  • Data stored on SQL data base
  • Web interface available for easy links to external databases
  • EX 6010 Extension Units or PS 6000 Power Supplies available if more units are required
  • Multi language user interfaces
  • A total of 4000 units (delegate and/or interpreter units) can be connected to the system.
  • Supports different User types with different priorities, user interfaces and control possibilities
  • Using screened CAT5 or CAT5e cabling (FTP or STP) ensuring a very cost effective installation and easy set-up of portable systems
  • Variety of printing facilities such as speaker’s log, voting results, delegates list etc.
  • Firmware in Delegate units, Interpreter Units, Central Units etc. upgradeable through serial PC-connection (RS232 or RS422)
  • Can be operated with or without a PC.
Page 6 of the Listen Technologies PS 6000 user manual — Voting equipment
Page 6 · click to enlarge
Page 6

System components

Conference equipment and channel selectors

The CU 6005/6010 Central Unit supports all available units in the DCS 6000 series:

CS 6032FV/H Channel Selector (flush mounted) DM 6010P Conference Unit (portable) DM 6060P Conference Unit (portable) with one built-in channel selector CM/DM 6070P Conference Unit (portable) with two built-in channel selectors CM/DM 6090P Conference Unit (portable) with two built-in channel selectors and XLR microphone connector CM/DM 6060F Conference Unit (flush mounted)

Central equipment etc.

EX 6010 Extension Unit PS 6000 Power Supply AO 6004 Audio Output box AO 6008 Audio Output box RP 6004 Repeater for four chains JB 6002 Junction Box with 2 outputs JB 6004 Junction Box with 4 outputs

with one built-in channel selectors CM/DM 6510F Conference Unit (flush mounted) with Chip-card and 3 voting buttons CM/DM 6560F Conference Unit (flush mounted) with one built-in channel selector, Chip-card and 3 voting buttons MU 6040C/D Microphone Unit for use with customised front plate with Loudspeaker, Microphone and Buttons. Available in Delegate (D) and Chairman (C) version MU 6042D Dual Microphone Unit for use with FD/FC front plate with Loudspeaker, Microphone and two delegate Buttons AM 6040 Ambient Noise Microphone

IS 6132P Interpreter Set LS 6132P Interpreter Loudspeaker

Voting equipment

DV 6501F Voting Unit

Interpreter equipment

Page 7 of the Listen Technologies PS 6000 user manual — System design
Page 7 · click to enlarge
Page 7

Operating instructions

PS 6000 Power Supply

General description

  • Delayed switching on of power to minimise the total ‘switch-on’ current on the Mains supply.

The PS 6000 Power Supply provides additional Power for the DCS 6000 system.

  • Designed in a small size easy-to-install cabinet.

Connectors

One CU 6005/6010 Central Unit is needed in each DCS 6000 system; however for expansion of the system the PS 6000 Power Supply is suitable. The PS 6000 consists of:

The PS 6000 Power Supply features the following connectors:

  • One Power Supply

Power connector Connection for main power.

  • Control electronic for detecting system power

Loop through connectors RJ45 connector, 2 pieces

Features

The main features of the PS 6000 Power Supply are:

DCS-LAN connectors used for connection to the CU 6005/6010 and for connection to other units with DCS-LAN connectors such as more PS 6000.

  • Built in Power Supply for app 60 units (Delegates) or app. 150 Channel Selectors

Power LED Those green LED light up when Power is available on the connector next to the LED.

  • One connector for connection to Delegate Units, Interpreter Units etc.
  • One connector for connection previous unit (i.e. CU 6005/6010.

System design

There are no settings to be done on the PS 6000 Power Supply.

And the PS 6000 is NOT a repeater, which means that the maximum cable length in a chain (which without repeater is 200 m) has to be calculated from the last unit with repeater functionality (typically a CU 6005/6010, EX 6010 or RP 6004) to the last unit connected to the PS 6000.

However it is important to observe, that the unit is only adding power to one of the chains on the CU 6005/6010 Central Unit.

And as so, the specification, which applies the two chain outputs on the CU 6005 Central Unit and to each of the chain outputs on the CU 6010 Central Unit, does also apply to the output on the PS 6000.

This includes interconnection cables between the units.

Page 8 of the Listen Technologies PS 6000 user manual — Use of PS 6000
Page 8 · click to enlarge
Page 8

Use of PS 6000

The PS 6000 can be inserted at any point in a DCS 6000 chain, where extra power is needed. The PS 6000 is used, when extra power is needed typically, where long feeding cables are needed.

A typical application is to place a PS 6000 in the first Interpreter Booth to compensate for a long feeding cable.

The following schematic shows various ways in how to use the PS 6000 Power Supply:

Listen Technologies PS 6000 — Use of PS 6000 diagram (page 8)
Fig. 3 · Use of PS 6000
Listen Technologies PS 6000 — Use of PS 6000 diagram (page 8)
Fig. 4 · Use of PS 6000
Page 9 of the Listen Technologies PS 6000 user manual — General guidelines
Page 9 · click to enlarge
Page 9

System Setup

General guidelines

Connect the PS 6000 to the various DCS 6000 units using Cat5 or Cat5e FTP or STP screened cables. Please observe the following guidelines:

between the units are short, more units can be connected than if the feeding cable is long and/or the cables are long between the units. Please consult the next section (Max. Number of units to be connected)

  • Maximum cable length in one chain is 200 m without repeater. This includes interconnection cables between the units. The max. usable cable length depends on the units connected and length of feeding cables etc.
  • If the last unit in one chain is a CS 6032 Channel Selector, this unit has to be terminated with an external termination, as the CS 6032 does not have an internal termination.
  • Maximum cable length in one chain when using repeaters is 650 m.

It is desirable that the square of the feeding cables especially, but also the interconnection cables are as big as possible to minimize the voltage drop in the cables. Cat 5/Cat5E cables are delivered in various gauges:

  • Although the output on the PS 6000 have a 125W supply, this 125W power is not all usable with long cables, as there will be a voltage drop in the feeding cable from the PS 6000 to the units connected. If the feeding cables are short and the cables

The following table is showing the Diameter/square for various AWG types

Type Diameter Square AWG22 0.64 mm 0.32 mm2

AWG23/1 0.57 mm 0.25 mm2

AWG24 0.53 mm 0.22 mm2

AWG26 0.42 mm 0.14 mm2

Page 10 of the Listen Technologies PS 6000 user manual — CM/DM 60x0P Chairman/Delegate Units & JB 6002 Junction Box
Page 10 · click to enlarge
Page 10

Max. number of units to be connected

The following tables show the maximum number of units, which can be connected to the two outputs (A1 or A2) on a CU 6005 Central Unit in total or to each of the four outputs (A1, A2, B1 or B2) on a

CU 6010 Central Unit or to each output on an EX 6010 Extension Unit or to the output of a PS 6000 Power Supply.

Listen Technologies PS 6000 — Max. number of units to be connected diagram (page 10)
Fig. 5 · Max. number of units to be connected
Length of Feeding CableLength of inter connectingTotal cable lengthMax. number of CM/DM Type CAT5 AWG24Cable, Type CAT5 AWG2460x0 pr output 10 m1 m51 m42 30 m1 m67 m38 50 m1 m83 m34 100 m1 m123 m24 150 m1 m165 m16 10 m2 m88 m40 30 m2 m98 m35 50 m2 m108 m30 100 m2 m142 m22 150 m2 m180 m16

CM/DM 60x0P Chairman/Delegate Units & JB 6002 Junction Box

This configuration shows two CM/DM 60x0 Delegate/Chairman Units connected to one JB 6002 Junction Box with 3m cables between each JB

6002. Maximum 5 m cable from JB 6002 to CM/DM 60x0 and max. one CM/DM 60x0 on each output of JB 6002.

Listen Technologies PS 6000 — CM/DM 60x0P Chairman/Delegate Units & JB 6002 Junction Box diagram (page 10)
Fig. 6 · CM/DM 60x0P Chairman/Delegate Units & JB 6002 Juncti…
Length of Feeding Cable,Length of Cable between eachTotal cableNumber ofMax. number of Type CAT5 AWG24JB 6002, Type CAT5 AWG24lengthJB 6002DM 60x0 10 m3 m61 m1836 30 m3 m75 m1632 50 m3 m89 m1428 100 m3 m127 m1020 150 m3 m168 m714
Page 11 of the Listen Technologies PS 6000 user manual — CM/DM 6060F/6510F Chairman/Delegate Units
Page 11 · click to enlarge
Page 11

CM/DM 6060F/6510F Chairman/Delegate Units

The following tables show the maximum number of units, which can be connected to the two outputs (A1 or A2) on a CU 6005 Central Unit in total or to each of the four outputs (A1, A2, B1 or B2) on a

CU 6010 Central Unit or to each output on an EX 6010 Extension Unit or to the output of a PS 6000 Power Supply.

Listen Technologies PS 6000 — CM/DM 6060F/6510F Chairman/Delegate Units diagram (page 11)
Fig. 7 · CM/DM 6060F/6510F Chairman/Delegate Units
Length of Feeding CableLength of inter connectingTotal cable lengthMax. number of Type CAT5 AWG24Cable, Type CAT5 AWG24CM/DM 60x0 pr output 10 m1 m39 m30 30 m1 m56 m27 50 m1 m73 m24 100 m1 m115 m16 150 m1 m160 m11 10 m2 m64 m28 30 m2 m78 m25 50 m2 m94 m23 100 m2 m130 m16 150 m2 m170 m11
Length of Feeding CableLength of inter-connectingTotal cable lengthMax. number of CM/DM Type CAT5 AWG24Cable, Type CAT5 AWG2460x0 pr output 10 m1 m35 m27 30 m1 m53 m24 50 m1 m70 m21 100 m1 m113 m14 150 m1 m159 m10 10 m2 m58 m25 30 m2 m72 m22 50 m2 m88 m20 100 m2 m126 m14 150 m2 m166 m9
Page 12 of the Listen Technologies PS 6000 user manual — IS 6132P Interpreter Units
Page 12 · click to enlarge
Page 12

MU 6040 C/D without connected loudspeaker

This table shows the maximum number of MU 6040 Microphone Units, which can be connected. The numbers are with no audio in loudspeaker (no

loudspeaker connected to each unit). If loudspeakers are used, then use the figures for CM/DM 60x0 above.

Listen Technologies PS 6000 — MU 6040 C/D without connected loudspeaker diagram (page 12)
Fig. 8 · MU 6040 C/D without connected loudspeaker
Length of Feeding Cable,Cable length betweenTotal cable lengthMax. number of Type CAT5 AWG24each MU 6040MU 6040 10 m2 m168 m80 30 m2 m178 m75 50 m2 m188 m70 100 m2 m200 m (202 m)51 (52*) 150 m2 m200 m (232 m)26 (42*) 100 m1 m151 m52 150 m1 m191 m42

Numbers in (‘) are the number of units, which could have been connected CU/EX, but where the total

number of units has been lowered due to the restriction of the maximum length of cable (200 m).

IS 6132P Interpreter Units

This table shows the maximum number of IS 6132P Interpreter Sets, which can be connected. The numbers are with no audio in loudspeaker (no loudspeaker connected to each unit).

If loudspeakers are used, then use the figures for CM/DM 60x0 above.

Listen Technologies PS 6000 — IS 6132P Interpreter Units diagram (page 12)
Fig. 9 · IS 6132P Interpreter Units

10m 2 m 54 x x 30m 2 m 49 57 60 50m 2 m 44 51 x 100m 2 m 35 40 x 150m 2 m 25 30 x

Page 13 of the Listen Technologies PS 6000 user manual — MU 6040 C/D without connected loudspeaker
Page 13 · click to enlarge
Page 13
Listen Technologies PS 6000 — MU 6040 C/D without connected loudspeaker diagram (page 13)
Fig. 10 · MU 6040 C/D without connected loudspeaker

10 m 5 m 19 4 0 10 m 5 m 12 4 4 30 m 5 m 17 4 0 30 m 5 m 10 4 4 50 m 5 m 15 4 0 50 m 5 m 9 4 4 100 m 5 m 11 4 0 100 m 5 m 7 4 4 150 m 5 m 8 4 0 150 m 5 m 5 4 4

Total cable length Max. number of CS 6032 pr

30 m 1 m 139 m 110 50 m 1 m 144 m 95 100 m 1 m 184 m 85 150 m 1 m 200 m 51 (67’) 10 m 2 m 200 m 96 30 m 2 m 200 m 86 (90’) 50 m 2 m 200 m 76 (85’) 100 m 2 m 200 m 51 (70’) 150 m 2 m 200 m 26 (60’) Numbers in (‘) are the number of units, which could have been connected to the CU/EX, but where the

total number of units has been lowered due to the restriction of the maximum length of cable (200 m).

Page 14 of the Listen Technologies PS 6000 user manual — Technical specifications
Page 14 · click to enlarge
Page 14
Listen Technologies PS 6000 — Accessories (not supplied) diagram (page 14)
Fig. 11 · Accessories (not supplied)
Pair 2Pin 3 & 6

CAT5 The DCS 6000 system uses CAT5, CAT5e or CAT6 FTP or STP cables with screened RJ45 connectors.

Pair 3Pin 4 & 5
Pair 4Pin 7 & 8

The phase of the pairs must be correct and the wiring spec. as stated in CAT5 (EIA 568-B) have to be followed.

EIA 568-B wiring shall be used.

It is important to use only FTP or STP (screened) cables and screened RJ45 connectors and not UTP cable, which is unscreened.

How to wire a CAT5 (EIA 568-B) Cable:

CAT6 can thus only be used for longer cable draws terminating in wall outlets or patch panels.

Listen Technologies PS 6000 — Accessories (not supplied) diagram (page 14)
Fig. 12 · Accessories (not supplied)

1 In-going + ORG/WHT ORG/WHT 2 In-going - ORG ORG 3 +48V GRN/WHT GRN/WHT 4 0V BLU BLU 5 0V BLU/WHT BLU/WHT 6 +48V GRN GRN 7 Outgoing - BRN/WHT BRN/WHT 8 Outgoing + BRN BRN

Accessories (not supplied)

Cat 5e Connection Cables (AWG24)

EC 6000-..5 Connection Cable 0.5 m 10 03 12500

EC 6000-01 Connection Cable 1 m 10 03 13101

EC 6000-02 Connection Cable 2 m 10 03 13201

EC 6000-05 Connection Cable 5 m 10 03 13501

EC 6000-10 Connection Cable 10 m 10 03 14102

EC 6000-20 Connection Cable 20 m 10 03 14202

pairs are connected as follows:

EC 6000-50 Connection Cable 50 m 10 03 14502

Technical specifications

General

Weight 1 kg

Power consumption max. 150W

Dimensions (W x H x D) 100 (125) x 50 x 205 mm

Mains voltage........................................100 - 240V, 50...60Hz

Dimensions in bracket are including the fixing bracket

Supply voltage for units 48V/125W

Accessories supplied Main cable

Temperature to guarantee specified performance

DCS-LAN loop through 2 pieces RJ45

5 Deg C. to 40 Deg C. (35 to 80% humidity)

Specifications are subject to change without notice.

-20 Deg C. to 60 Deg C. (10 to 80% humidity)

Connectors · Storage temperature

Ask about the Listen Technologies PS 6000

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Listen Technologies PS 6000

Be the first to ask — other owners or our team will answer.

Original document

Listen Technologies PS 6000 manual PDF

14 pages·123 KB·Power Supply·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…