EN
Linksys logo
Official user manual

Linksys SLM2008

32 pages·2.5 MB·Switch·PDF·ENDEFRITNLJA
Linksys SLM2008
Table of Contents 60 sections Chapter 1: Introduction · Chapter 2: Product Overview · Front Panel · Back Panel · … ShowHide
Chapter 1: Introductionp.5Chapter 2: Product Overviewp.6Front Panelp.6Back Panelp.6Side Panelsp.6Chapter 3: Installationp.7Overviewp.7Pre-Installation Considerationsp.7Full-Duplex Considerationsp.71000BASE-T Cable Requirementsp.7Positioning the Switchp.7Placement Optionsp.8Wall-Mount Placementp.8Desktop Placementp.8Hardware Installationp.8Chapter 4: Advanced Configurationp.9Setupp.9System > System Settingsp.9Port > Port Settingsp.10Port > Static Link Aggregationp.10Port > LACP Settingsp.10Port > LACP Statusp.11VLAN > VLAN Settingsp.11VLAN > VLAN Port Settingsp.11Security > 802.1X Settingsp.12Security > 802.1X Parameterp.13Security > Static MAC Addressp.13Security > Management Access Listp.13Security > Storm Controlp.14Rate Thresholdp.14QoS > QoS Settingsp.14Queue Modep.14QoS Modep.15STP > STP Settingsp.15STP Port Settingsp.16STP > STP Statusp.16STP VLAN Bridge Overviewp.16STP Port Statusp.16Statistics > Statistics Overviewp.16Statistics > IGMP Statusp.17Multicast > IGMP Settingsp.17Admin > Pingp.17Ping Parametersp.18Admin > Port Mirrorp.18Admin > Factory Defaultp.18Admin > Rebootp.18Admin > Save Configurationp.18Admin > Firmware Upgradep.19Appendix A: Glossaryp.20Appendix B: Specificationsp.24SLM2005p.24SLM2008p.25Appendix C: Warranty and Regulatory Informationp.26Limited Warrantyp.26FCC Statementp.27Safety Noticesp.27Industry Canada Statementp.27Règlement d’Industry Canadap.27User Information for Consumer Products Covered by EU Directive 2002/96/EC on Waste Electric and Electronic Equipment (WEEE)p.28Appendix D: Contact Informationp.32
Page 1 of the Linksys SLM2008 user manual — Model: SLM2005, SLM2008
Page 1 · click to enlarge
Page 1
Linksys SLM2008 diagram (page 1)
Fig. 1
Linksys SLM2008 diagram (page 1)
Fig. 2

USER GUIDE

BUSINESS SERIES 5-Port and 8-Port 10/100/1000 Gigabit Smart Switch with PD and AC Power

Model: SLM2005, SLM2008

Page 2 of the Linksys SLM2008 user manual — Copyright and Trademarks
Page 2 · click to enlarge
Page 2

About This Guide

About This Guide

Icon Descriptions

While reading through the User Guide you may encounter various icons designed to call attention to a specific item. Below is a description of these icons:

WEB: This globe icon indicates a noteworthy website address or e-mail address.

Online Resources

Most web browsers allow you to enter the web address without adding the http:// in front of the address. This User Guide will refer to websites without including http:// in front of the address. Some older web browsers may require you to add it.

ResourceWebsite Linksyswww.linksys.com Linksys Internationalwww.linksys.com/international Glossarywww.linksys.com/glossary Network Securitywww.linksys.com/security

Copyright and Trademarks

Specifications are subject to change without notice. Linksys is a registered trademark or trademark of Cisco Systems, Inc. and/or its affiliates in the U.S. and certain other countries. Copyright © 2007 Cisco Systems, Inc. All rights reserved. Other brands and product names are trademarks or registered trademarks of their respective holders.

5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Page 3 of the Linksys SLM2008 user manual — Table of contents
Page 3 · click to enlarge
Page 3

Table of contents

Chapter 1: Introductionp.5Chapter 2: Product Overviewp.6Front Panelp.6Back Panelp.6Side Panelsp.6Chapter 3: Installationp.7Overviewp.7Pre-Installation Considerationsp.7Full-Duplex Considerationsp.71000BASE-T Cable Requirementsp.7Positioning the Switchp.7Placement Optionsp.8Wall-Mount Placementp.8Desktop Placementp.8Hardware Installationp.8Chapter 4: Advanced Configurationp.9Setupp.9System > System Settingsp.9Port > Port Settingsp.10Port > Static Link Aggregationp.10Port > LACP Settingsp.10Port > LACP Statusp.11VLAN > VLAN Settingsp.11VLAN > VLAN Port Settingsp.11Security > 802.1X Settingsp.12Security > 802.1X Parameterp.13Security > Static MAC Addressp.13Security > Management Access Listp.13Security > Storm Controlp.14Rate Thresholdp.14QoS > QoS Settingsp.14Queue Modep.14QoS Modep.15STP > STP Settingsp.15STP Port Settingsp.16STP > STP Statusp.16STP VLAN Bridge Overviewp.16STP Port Statusp.16Statistics > Statistics Overviewp.16Statistics > IGMP Statusp.17Multicast > IGMP Settingsp.17Admin > Pingp.17Ping Parametersp.18Admin > Port Mirrorp.18Admin > Factory Defaultp.18Admin > Rebootp.18Admin > Save Configurationp.18Admin > Firmware Upgradep.19Appendix A: Glossaryp.20Appendix B: Specificationsp.24SLM2005p.24SLM2008p.25Appendix C: Warranty and Regulatory Informationp.26Limited Warrantyp.26FCC Statementp.27Safety Noticesp.27Industry Canada Statementp.27Règlement d’Industry Canadap.27User Information for Consumer Products Covered by EU Directive 2002/96/EC on Waste Electric and Electronic Equipment (WEEE)p.28Appendix D: Contact Informationp.32
Page 4 of the Linksys SLM2008 user manual — Table of contents
Page 4 · click to enlarge
Page 4

Table of contents

Chapter 1: Introductionp.5Chapter 2: Product Overviewp.6Front Panelp.6Back Panelp.6Side Panelsp.6Chapter 3: Installationp.7Overviewp.7Pre-Installation Considerationsp.7Full-Duplex Considerationsp.71000BASE-T Cable Requirementsp.7Positioning the Switchp.7Placement Optionsp.8Wall-Mount Placementp.8Desktop Placementp.8Hardware Installationp.8Chapter 4: Advanced Configurationp.9Setupp.9System > System Settingsp.9Port > Port Settingsp.10Port > Static Link Aggregationp.10Port > LACP Settingsp.10Port > LACP Statusp.11VLAN > VLAN Settingsp.11VLAN > VLAN Port Settingsp.11Security > 802.1X Settingsp.12Security > 802.1X Parameterp.13Security > Static MAC Addressp.13Security > Management Access Listp.13Security > Storm Controlp.14Rate Thresholdp.14QoS > QoS Settingsp.14Queue Modep.14QoS Modep.15STP > STP Settingsp.15STP Port Settingsp.16STP > STP Statusp.16STP VLAN Bridge Overviewp.16STP Port Statusp.16Statistics > Statistics Overviewp.16Statistics > IGMP Statusp.17Multicast > IGMP Settingsp.17Admin > Pingp.17Ping Parametersp.18Admin > Port Mirrorp.18Admin > Factory Defaultp.18Admin > Rebootp.18Admin > Save Configurationp.18Admin > Firmware Upgradep.19Appendix A: Glossaryp.20Appendix B: Specificationsp.24SLM2005p.24SLM2008p.25Appendix C: Warranty and Regulatory Informationp.26Limited Warrantyp.26FCC Statementp.27Safety Noticesp.27Industry Canada Statementp.27Règlement d’Industry Canadap.27User Information for Consumer Products Covered by EU Directive 2002/96/EC on Waste Electric and Electronic Equipment (WEEE)p.28Appendix D: Contact Informationp.32
Page 5 of the Linksys SLM2008 user manual — Chapter 1
Page 5 · click to enlarge
Page 5

Chapter 1

Introduction

Chapter 1: Introduction

The 5-port and 8-port 10/100/1000 Gigabit Smart Switches with PD and AC Power allow you to upgrade your existing 10/100 network by replacing your current workgroup hub or switch. At the same time, you can configure advanced features for security, QoS, and Spanning Tree using its web-based utility.

The Linksys Gigabit Smart Switches not only allow you to upgrade to Gigabit speeds, but also allow you to expand your network securely. The Gigabit Smart Switches with PD have virtual LAN (VLAN) capabilities to restrict the flow of multicast and broadcast traffic. Stations within a given VLAN can freely communicate using either unicast or multicast addressing. Communication between different VLANs is not possible.

Extensive QoS features make the solution ideal for real‑time applications like Voice and Video. The 4 priority queues together with the Weighted Round Robin and Strict Priority scheduling techniques facilitate efficient coexistence of real-time traffic with data traffic allowing them each to meet their QoS needs. Individual users or applications can be prioritized above others using various Class of Service options - by port, layer 2 priority (802.1p), and layer 3 priority (TOS or DSCP). Intelligent broadcast and multicast storm controls minimize and contain the effects of these types of traffic on regular traffic. IGMP Snooping limits bandwidth-intensive video traffic to only the requestors without flooding all users. Incoming traffic can be policed and outgoing traffic can be shaped allowing you to control network access and traffic flow.

There are features that allow you to expand and grow your network of switches. Link aggregation allows multiple high-bandwidth trunks between switches to be setup. This also provides a level of reliability in that the system continues to operate if one of the links breaks. Spanning Tree (STP) allow you to build a mesh of switches increasing the availability of the system.

5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Page 6 of the Linksys SLM2008 user manual — Back Panel
Page 6 · click to enlarge
Page 6

Chapter 2

Product Overview

Side Panels

Chapter 2: Product Overview

The Reset button and Power port are located on the right side panel of the Switch.

Front Panel

Linksys SLM2008 — Front Panel diagram (page 6)
Fig. 3 · Front Panel

The LEDs are located on the front panel of the Switch.

Linksys SLM2008 — Front Panel diagram (page 6)
Fig. 4 · Front Panel

Reset Button The Reset button can be used to reset or reboot the Switch.

Front Panel - SLM2008

Reboot If the button is pressed for less than 10 seconds, the Switch will reboot.

System (Green) Lights up green to indicate that power is being supplied to the Switch.

Restore Factory Defaults If the button is pressed for longer than 10 seconds, the Switch’s settings will be restored to the factory defaults.

1-5 or 1-8 (Green) Each LED will light up when there is a connection made through its corresponding port. It will flash when there is activity on its corresponding port.

Back Panel

The Ethernet ports are located on the back panel of the Switch.

Linksys SLM2008 — Back Panel diagram (page 6)
Fig. 5 · Back Panel

Power The Power port is where you will connect the AC power.

The security slot is located on the left side panel of the Switch.

Back Panel - SLM2008

Linksys SLM2008 — Back Panel diagram (page 6)
Fig. 6 · Back Panel

Ethernet 1 The Switch’s first RJ-45 port supports the IEEE 802.3af Power-over-Ethernet (PoE) PD standard that enables DC power to be supplied to the Switch using wires in the connecting twisted‑pair cable. Any 802.3af-compliant Power over Ethernet device attached to the port can directly supply power to the Switch over the twisted-pair cable without requiring its own separate power source.

Security Slot The security slot can be utilized to attach a lock to the Switch.

To connect a device to a port, you will need to use Category 5e (or better) network cable.

Ethernet 1-5 or 1-8 These RJ-45 ports support network speeds of either 10Mbps, 100Mbps, or 1000Mbps and can operate in half and full‑duplex modes. Auto-sensing technology enables each port to automatically detect the speed of the device connected to it and adjust its speed and duplex accordingly.

5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Show 4 more labels / short text on this page
Right Side Panel · • · • · Left Side Panel
Page 7 of the Linksys SLM2008 user manual — Positioning the Switch
Page 7 · click to enlarge
Page 7

Chapter 3

Installation

Pre-Installation Considerations

Chapter 3: Installation

Full-Duplex Considerations

The Switch provides full-duplex support for its RJ-45 ports. Full-duplex operation allows data to be sent and received simultaneously, doubling a port’s potential data throughput. If you will be using the Switch in full-duplex mode, the maximum cable length using Category 5 cable is 328 feet (100 meters).

Overview

This chapter will explain how to connect network devices to the Switch. The following diagram shows a typical network configuration.

1000BASE-T Cable Requirements

All Category 5 UTP cables that are used for 100BASE-TX connections should also work for 1000BASE-T, providing that all four wire pairs are connected. However, it is recommended that for all critical connections, or any new cable installations, Category 5e (enhanced Category 5) or Category 6 cable should be used. The Category 5e specification includes test parameters that are only recommendations for Category 5. Therefore, the first step in preparing existing Category 5 cabling for running 1000BASE-T is a simple test of the cable installation to be sure that it complies with the IEEE 802.3ab standards.

Linksys SLM2008 — 1000BASE-T Cable Requirements diagram (page 7)
Fig. 7 · 1000BASE-T Cable Requirements

Positioning the Switch

Before you choose a location for the Switch, observe the following guidelines:

Make sure that the Switch is accessible and that the cables can be connected easily.

Keep cabling away from sources of electrical noise, power lines, and fluorescent lighting fixtures.

When you connect your network devices, make sure you don’t exceed the maximum cabling distance of 100 meters (328 feet).

Position the Switch away from water and moisture sources.

To ensure adequate air flow around the Switch, be sure to provide a minimum clearance of two inches (50mm).

Do not stack free-standing Switches more than four units high.

5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Show 14 more labels / short text on this page
Cable/DSL · Wireless Access · Internet · Modem Router · Point · Powered by · Desktop Notebook Server · • · Switch · Typical Network Configuration · • · • · • · •
Page 8 of the Linksys SLM2008 user manual — 2 ½ inches
Page 8 · click to enlarge
Page 8

Chapter 3

Installation

Placement Options

Desktop Placement

There are two ways to physically install the Switch, either hang the Switch on a wall using its wall-mount slots or place it on a desktop.

Place the Switch on a desktop near an AC power source.

Keep enough ventilation space for the switch and check the environmental restrictions mentioned in “Appendix B: Specifications” as you are placing the Switch.

Wall-Mount Placement

You will need 2 suitable screws to mount the Switch.

Connect the Switch to network devices according to the Hardware Installation instructions below.

2.5-3 mm

Hardware Installation

4-5 mm 1-2 mm

To connect network devices to the Switch, follow these instructions:

Make sure all the devices you will connect to the Switch are powered off.

Connect a Category 5e Ethernet network cable to one of the numbered ports on the Switch.

Determine where you want to mount the Switch. Ensure that the wall you use is smooth, flat, dry and sturdy and make sure the location is within reach of the power outlet.

Drill two holes into the wall. Make sure the holes are 2 ½ inches apart.

Connect the other end to a PC or other network device.

Insert a screw into each hole, and leave 3 mm of its head exposed.

Repeat steps 2 and 3 to connect additional devices.

Maneuver the Switch so the wall-mount slots line up with the two screws.

Provide power to the Switch in one of two ways:

Connect a Category 5e Ethernet network cable from port 1 of the Switch to a network device with the ability to provide Power over Ethernet.

Place the wall-mount slots over the screws and slide the Switch down until the screws fit snugly into the wall-mount slots.

Connect the supplied power cord to the Switch’s power port, and plug the other end into an electrical outlet. When connecting power, always use a surge protector.

Congratulations! The Wall-Mount installation of the Switch is complete.

Power on the devices connected to the Switch. Each active port’s corresponding LED will light up on the Switch.

Hardware installation is complete.

2 ½ inches

Print this page at 100% size, cut along the dotted line and place on the wall to drill precise spacing.

5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Show 7 more labels / short text on this page
• · • · • · Suggested Mounting Hardware · • · • · Wall Mounting Template
Page 9 of the Linksys SLM2008 user manual — System > System Settings
Page 9 · click to enlarge
Page 9

System Name This field allows you to enter/modify the name of the Switch.

System Location This field allows you to enter/modify the location name of the Switch.

Open your web browser and enter http://192.168.1.254 into the address field. Press the Enter key and the Password screen will appear.

MAC Address The MAC address of the Switch is displayed here.

S/W Version The software version of the Switch is displayed here.

Linksys SLM2008 — Chapter 4: Advanced Configuration diagram (page 9)
Fig. 8 · Chapter 4: Advanced Configuration
Linksys SLM2008 — Chapter 4: Advanced Configuration diagram (page 9)
Fig. 9 · Chapter 4: Advanced Configuration

IP Address The IP address assigned to the Switch is displayed. The default IP address is 192.168.1.254.

Subnet Mask The Subnet Mask assigned to the Switch is displayed. The default is 255.255.255.0.

Default Gateway Displays the IP address of the gateway between this device and management stations that exist on other network segments. The default value is 0.0.0.0.

The first time you open the web‑based utility, enter admin (the default username) in the username field and leave the password blank. Click the OK button. You can set a password later from the System > System Settings screen.

DHCP Server The IP address of the DHCP server.

Enable DHCP When enabled, the Switch will attempt to obtain an IP address from a DHCP server on your network. If an IP address is not obtained, the Switch will use the IP address defined in the IP Address field below.

Linksys SLM2008 — Chapter 4: Advanced Configuration diagram (page 9)
Fig. 10 · Chapter 4: Advanced Configuration
Linksys SLM2008 — Chapter 4: Advanced Configuration diagram (page 9)
Fig. 11 · Chapter 4: Advanced Configuration

IP Address The IP address assigned to the Switch can be modified in this field. The default IP address is 192.168.1.254.

Setup

The first screen displayed upon login is the System Settings screen. There are 10 options across the top of the screen: System, Port, VLAN, Security, QoS, STP, Statistics, Multicast, Admin and Logout. Each option contains screens that will help you configure and manage the Switch.

Subnet Mask The Subnet Mask assigned to the Switch can be modified in this field. The default is 255.255.255.0.

Default Gateway The IP address of the gateway can be modified in this field. The default is 0.0.0.0.

System > System Settings

Management VLAN Enter the ID of the configured VLAN (1-4094, no leading zeroes). By default, all ports on the Switch are members of VLAN 1. However, the management station can be attached to a port belonging to any VLAN, as long as that VLAN has been assigned an IP address.

The System > System Settings screen displays a summary of Switch information.

Linksys SLM2008 — System > System Settings diagram (page 9)
Fig. 12 · System > System Settings
Linksys SLM2008 — System > System Settings diagram (page 9)
Fig. 13 · System > System Settings

Username Specifies the username. The default username is admin. Only one admin user is allowed.

Password A new password can be entered in this field. The password is not displayed as it is entered. Each character is displayed as a bullet in the password field.

Web Admin Timeout (secs) As a security measure, the web-based utility will timeout after being idle for the amount of time defined in this field. If the Switch is idle for the amount of time defined here, login is required to return to the web-based utility. The time is entered in seconds. The default value is 300 seconds.

System > System Settings

5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Address Bar · Login Screen

Page 10 of the Linksys SLM2008 user manual — Port > LACP Settings
Page 10 · click to enlarge
Page 10

Port > Static Link Aggregation

Be sure to click Save Settings and reboot the Switch by going to Admin > Reboot.

You can create multiple links between devices that work as one virtual, aggregate link (LAG). An aggregated link offers a dramatic increase in bandwidth for network segments where bottlenecks exist, as well as providing a fault-tolerant link between two devices. You can create up to two LAGs on the Switch. Each LAG can contain up to five/eight ports.

Port > Port Settings

You can manually configure the speed, duplex, and flow control settings used on specific ports, or use autonegotiation to allow the Switch to autodetect the connection settings used by the attached device. Full‑duplex mode should be used on ports whenever possible to double the throughput of Switch connections. Flow control should also be enabled to control network traffic during periods of congestion and prevent the loss of packets when port buffer thresholds are exceeded. The Switch supports flow control based on the IEEE 802.3x standard.

Linksys SLM2008 — Port > Port Settings diagram (page 10)
Fig. 14 · Port > Port Settings
Linksys SLM2008 — Port > Port Settings diagram (page 10)
Fig. 15 · Port > Port Settings
Linksys SLM2008 — Port > Port Settings diagram (page 10)
Fig. 16 · Port > Port Settings

Port > Link Aggregation

LAG Displays the LAG number. By selecting the Port numbers, the port can be added to the LAG group.

Click Save Settings to save any changes.

Port > LACP Settings

Ports > Port Settings

Ports can be statically grouped into an aggregate link (that is, LAG) to increase the bandwidth of a network connection or to ensure fault recovery. Or you can use the Link Aggregation Control Protocol (LACP) to automatically negotiate a LAG link between the Switch and another network device. For dynamic LAGs, the switches have to comply with LACP. This Switch supports up to two LAGs. For example, a LAG consisting of two 1000 Mbps ports can support an aggregate bandwidth of 4 Gbps when operating at full duplex.

Port Displays the port number.

Link Status Displays the link status of the port.

Mode The current speed and duplex mode settings are displayed here. Auto Speed is enabled by default to allow the Switch to autonegotiate the speed and duplex settings. The following capabilities are supported:

Auto Speed This option enables autonegotiation. When autonegotiation is enabled, you do not need to specify the capabilities to be advertised.

To avoid creating a loop in the network, be sure you enable LACP before connecting the ports, and also disconnect the ports before disabling LACP.

10 Half Supports 10 Mbps half-duplex operation.

10 Full Supports 10 Mbps full-duplex operation.

100 Half Supports 100 Mbps half-duplex operation.

100 Full Supports 100 Mbps full-duplex operation.

1000 Full Supports 1000 Mbps full-duplex operation.

Disabled Disables the port.

Flow Control Indicates whether flow control is enabled or not.

LAG Indicates whether the port is a LAG member.

Enable Jumbo Frames Selecting this enables Jumbo Frame support (up to 9KB).

Be sure to click Save Settings to retain any changes.

5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Show 7 more labels / short text on this page
• · • · • · • · • · • · •
Page 11 of the Linksys SLM2008 user manual — VLAN > VLAN Port Settings
Page 11 · click to enlarge
Page 11

VLAN > VLAN Settings

Linksys SLM2008 — VLAN > VLAN Settings diagram (page 11)
Fig. 17 · VLAN > VLAN Settings
Linksys SLM2008 — VLAN > VLAN Settings diagram (page 11)
Fig. 18 · VLAN > VLAN Settings

A VLAN is a group of ports that can be located anywhere in the network, but communicate as though they belong to the same physical segment. VLANs help to simplify network management by allowing you to move devices to a new VLAN without having to change any physical connections. VLANs can be easily organized to reflect departmental groups (such as Marketing or R&D), usage groups (such as e-mail), or multicast groups (used for multimedia applications such as videoconferencing). You can create up to 16 VLANs on the Switch.

Port > LACP Settings

Port Displays the port number.

Enable LACP Enables LACP.

To create a single VLAN, enter the VLAN ID, and click Add. Use the VLAN ID screen to configure port members or LAG members for a specific VLAN index.

Admin Key A channel will only be formed between ports having the same admin key. This only applies to ports located on the same switch. The default setting is auto.

Linksys SLM2008 — VLAN > VLAN Settings diagram (page 11)
Fig. 19 · VLAN > VLAN Settings

Click Save Settings to save any changes.

Port > LACP Status

From the LACP Status screen, you will see the LACP Status for each port, and its partner port number, and operational port key.

Linksys SLM2008 — Port > LACP Status diagram (page 11)
Fig. 20 · Port > LACP Status
Linksys SLM2008 — Port > LACP Status diagram (page 11)
Fig. 21 · Port > LACP Status

VLAN > VLAN Settings

VLAN ID ID of configured VLAN (1-4094, no leading zeroes).

To remove a VLAN, select the VLANs in the VLAN list, then click Delete.

Click Save Settings to save any changes.

VLAN > VLAN Port Settings

Port > LACP Status

LACP Port Status LACP Status on each interface since the device was last refreshed.

You can configure VLAN behavior for specific interfaces, including the mode, accepted frame type, VLAN identifier (PVID), and ingress filtering.

Protocol Active Indicates if the LACP is disabled or enabled on the interface.

Linksys SLM2008 — VLAN > VLAN Port Settings diagram (page 11)
Fig. 22 · VLAN > VLAN Port Settings
Linksys SLM2008 — VLAN > VLAN Port Settings diagram (page 11)
Fig. 23 · VLAN > VLAN Port Settings

Partner Port Number Indicates the port that is in the same LAG group.

Operational Port Key A channel will only be formed between ports having the same operational port key. This only applies to ports located on the same switch.

VLAN > VLAN Port Settings

7 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Page 12 of the Linksys SLM2008 user manual — Security > 802.1X Settings
Page 12 · click to enlarge
Page 12

Enable Tx Force Untag When this option is enabled, all egress frames from this port become untagged. The default value is Disable. When this function is disabled, only frames with the VLAN ID equal to the PVID will become untagged, otherwise, frames are sent with a VLAN tag.

The IEEE 802.1X (dot1X) standard defines a port-based access control procedure that prevents unauthorized access to a network by requiring users to first submit credentials for authentication. Access to all switch ports in a network can be centrally controlled from a server, which means that authorized users can use the same credentials for authentication from any point within the network.

Enable Ingress Filter Determines how to process frames tagged for VLANs for which the ingress port is not a member. The default value is enabled. Ingress filtering only affects tagged frames. If ingress filtering is disabled and a port receives frames with a VLAN tag that uses a different PVID than the receiving port, the packet types will be forwarded to the port belonging to the appropriate VLAN (determined by the VLAN tag). If ingress filtering is enabled and a port receives frames tagged for VLANs for which it is not a member, these frames will be discarded.

This Switch uses the Extensible Authentication Protocol over LANs (EAPOL) to exchange authentication protocol messages with the client, and a remote RADIUS authentication server to verify user identity and access rights. When a client connects to a switch port, the Switch responds with an EAPOL identity request. The client provides its identity (such as a user name) in an EAPOL response to the Switch, which it forwards to the RADIUS server. The RADIUS server verifies the client identity and sends an access challenge back to the client. The EAP packet from the RADIUS server contains not only the challenge, but the authentication method to be used. The client can reject the authentication method and request another, depending on the configuration of the client software and the RADIUS server. The authentication method must be MD5. The client responds to the appropriate method with its credentials, such as a password or certificate. The RADIUS server verifies the client credentials and responds with an accept or reject packet. If authentication is successful, the Switch allows the client to access the network. Otherwise, network access is denied and the port remains blocked.

Acceptable Frame Type Sets the interface to accept all frame types, including tagged or untagged frames, or only tagged frames. When set to receive all frame types, any received frames that are untagged are forwarded to the VLAN based on the PVID of its ingress port. All frame types are selected by default.

PVID (Port VLAN identifier) VLAN ID assigned to untagged frames received on the interface. The default value is 1. For all other VLANs, an interface must first be configured as an untagged member before you can assign its PVID to that group.

Fill in the required settings for each interface, then click Save Settings.

The operation of 802.1X on the Switch requires the following:

Security > 802.1X Settings

Network switches can provide open and easy access to network resources by simply attaching a client PC. Although this automatic configuration and access is a desirable feature, it also allows unauthorized personnel to easily intrude and possibly gain access to sensitive network data.

The Switch must have an IP address assigned.

RADIUS authentication must be enabled on the Switch and the IP address of the RADIUS server specified.

802.1X must be enabled globally for the Switch.

Each Switch port that will be used must be set to dot1X “Auto” mode.

Linksys SLM2008 — Security > 802.1X Settings diagram (page 12)
Fig. 24 · Security > 802.1X Settings
Linksys SLM2008 — Security > 802.1X Settings diagram (page 12)
Fig. 25 · Security > 802.1X Settings

Each client that needs to be authenticated must have dot1X client software installed and properly configured.

The RADIUS server and 802.1X client support EAP. (The Switch only supports EAPOL in order to pass the EAP packets from the server to the client.)

The RADIUS server and client also have to support the same EAP authentication type – MD5. (Some clients have native support in Windows, otherwise the dot1x client must support it.)

Security > 802.1X Settings

802.1X Mode Enables or disables 802.1X mode.

RADIUS IP Enter the IP address of the server.

5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Show 7 more labels / short text on this page
• · • · • · • · • · • · •
Page 13 of the Linksys SLM2008 user manual — Security > Management Access List
Page 13 · click to enlarge
Page 13

RADIUS UDP Port Enter the UDP Port of the server. The UDP port is used to verify the RADIUS server authentication. The default value is 1812.

EAP Timeout (1-255 seconds) Sets the time period during an authentication session that the Switch waits before retransmitting an EAP packet. The default value is 30 seconds.

Key String Enter the secret key string as defined on the RADIUS server. The secret key string is used for authenticating and encrypting communications between the device and the RADIUS server.

Click Save Settings to save any changes.

Security > Static MAC Address

Admin State Sets the authentication mode to one of the following options:

Static MAC Address allows you to configure a switch port with the MAC address of one or more devices that are authorized to access the network through that port. The MAC address is bound to the ingress port specified on the list and does not allow the MAC address to change ports. Only incoming traffic with source addresses already stored in the static address table will be accepted as authorized to access the network through that port. MAC addresses on the list do not age out.

Auto Requires a dot1x-aware client to be authorized by the authentication server. Clients that are not dot1x‑aware will be denied access.

Force-Authorized Forces the port to grant access to all clients, either dot1x-aware or otherwise. (This is the default setting.)

Force-Unauthorized Forces the port to deny access to all clients, either dot1x-aware or otherwise.

Linksys SLM2008 — Security > Static MAC Address diagram (page 13)
Fig. 26 · Security > Static MAC Address
Linksys SLM2008 — Security > Static MAC Address diagram (page 13)
Fig. 27 · Security > Static MAC Address

Port State Displays the state of the 802.1X for each port.

Re-authenticate It will trigger the switch to ask a connected client to restart authentication process.

Force Reinitialize It will trigger the specific port of the switch to restart 802.1X process.

Statistics The Switch can display statistics for 802.1X protocol exchanges for any port.

Security > Static MAC Address

Click Save Settings to save any changes.

MAC Address Enter the specific MAC address for the system to store and decide the destination port to forward.

Security > 802.1X Parameter

When 802.1X is enabled, you need to configure the parameters for the authentication process that runs between the client and the Switch. The client identity lookup process that runs between the Switch and authentication server also needs to be configured. These parameters are described in this section.

VLAN ID Enter the VLAN ID associated with the specific MAC address.

Port Select the port associated with the specific MAC address.

Click Save Settings to save any changes.

Linksys SLM2008 — Security > 802.1X Parameter diagram (page 13)
Fig. 28 · Security > 802.1X Parameter

Security > Management Access List

Management Access List specifies which Source IP addresses can manage the device.

Linksys SLM2008 — Security > Management Access List diagram (page 13)
Fig. 29 · Security > Management Access List

Security > 802.1X Parameter

Enable Reauthentication Enables re-authentication.

Reauthtentication Period (1-3600 seconds) Sets the time period after which a connected client must be re‑authenticated. The default value is 3600 seconds.

Security > Management Access List

Enable Management Access List Enable IP Access List.

5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Page 14 of the Linksys SLM2008 user manual — QoS > QoS Settings
Page 14 · click to enlarge
Page 14

Management IP address 1 Enter the IP address of a device that you wish to allow manage the Switch.

A combination of these attributes

Management IP address 2 Enter the IP address of a second device that you wish to allow manage the Switch.

Providing various mechanisms for determining the allocation of network resources to different handling classes, including:

Management IP address 3 Enter the IP address of a third device that you wish to allow manage the Switch.

The assignment of network traffic to a particular hardware queue

Management IP address 4 Enter the IP address of a fourth device that you wish to allow manage the Switch.

The assignment of internal resources

Management IP address 5 Enter the IP address of a fifth device that you wish to allow manage the Switch.

You can set the Switch to service the queues based on a strict rule that requires all traffic in a higher priority queue to be processed before lower priority queues are serviced, or use Weighted Round-Robin (WRR) queuing that specifies a relative weight of each queue. WRR uses a pre‑defined relative weight for each queue that determines the percentage of service time the Switch services each queue before moving on to the next queue. This prevents the head-of-line blocking that can occur with strict priority queuing.

Click Save Settings to save any changes.

Security > Storm Control

Rate Threshold

The maximum rate (packets per second) at which unknown packets are forwarded.

Linksys SLM2008 — Rate Threshold diagram (page 14)
Fig. 30 · Rate Threshold
Linksys SLM2008 — Rate Threshold diagram (page 14)
Fig. 31 · Rate Threshold

Security > Storm Control

QoS > QoS Settings

Broadcast Rate You can select the storm control broadcast rate threshold from the list or select the default value, No Limit.

Queue Mode

Set the Queue Mode to Strict Priority or WRR.

Multicast Rate You can select the storm control multicast rate threshold from the list or select the default value, No Limit.

Strict Priority Services the egress queues in sequential order, transmitting all traffic in the higher priority queues before servicing lower priority queues.

Click Save Settings to save any changes.

WRR Weighted Round-Robin shares bandwidth at the egress ports by using scheduling weights 1, 2, 4, 8 for queues 1 through 4 respectively.

QoS > QoS Settings

WRR Weight Displays the WRR weights to queues.

Network traffic is usually unpredictable and the only basic assurance that can be offered is best effort traffic delivery. To overcome this challenge, Quality of Service (QoS) is applied throughout the network. This ensures that network traffic is prioritized according to specified criteria, and that specific traffic receives preferential treatment. QoS in the network optimizes network performance and entails two basic facilities:

Classifying incoming traffic into handling classes, based on an attribute, including:

The ingress interface •

10 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Show 5 more labels / short text on this page
• · Packet content · • · • · •
Page 15 of the Linksys SLM2008 user manual — Port-Based
Page 15 · click to enlarge
Page 15

QoS Mode

Port-Based Settings

Set the QoS Mode to QoS Disabled, 802.1p, Port Based, or DSCP.

This allows customization of priority levels for specific ports. By default, all ports are set to high priority.

DSCP

The Switch supports a common method of prioritizing IP traffic to meet application requirements. Traffic priorities can be mapped to one of 4 priority queues based on the DSCP (Differentiated Services Code Point) value.

802.1p Enabled?

802.1p QoS

DSCP Settings

Linksys SLM2008 — DSCP Settings diagram (page 15)
Fig. 32 · DSCP Settings

DSCP Settings enable mapping DSCP values to specific priority levels. The default DSCP settings are shown in the following table:

QoS Mode Priority Diagram

DSCP Value (0-63) Priority

802.1p

802.1p QoS Mode allows you to specify data packet priority based on the 802.1p value in VLAN priority tag of the packet. Users can map 802.1p to one of 4 priority queues.

Prioritize Traffic

DSCP Value Indicates the Differentiated Services Code Point value in the incoming packet.

Allows you to select a traffic prioritization setting. The default value is Custom.

Priority Maps the DSCP value to the selected priority level.

802.1p Settings

The default 802.1p settings are shown in the following table:

Click Save Settings to save any changes.

STP > STP Settings

Default 802.1p Settings

802.1p Value Priority Level

The Spanning Tree Algorithm (STA) can be used to detect and disable network loops, and to provide backup links between switches, bridges or routers. This allows the Switch to interact with other bridging devices (that is, an STA-compliant switch, bridge or router) in your network to ensure that only one route exists between any two stations on the network, and provide backup links which automatically take over when a primary link goes down.

Linksys SLM2008 — STP > STP Settings diagram (page 15)
Fig. 33 · STP > STP Settings
Linksys SLM2008 — STP > STP Settings diagram (page 15)
Fig. 34 · STP > STP Settings

Port-Based

Port-Based QoS mode allows you to set priority levels for each port.

STP > STP Settings

11 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Show 25 more labels / short text on this page
DSCP Found? · Yes Yes · DSCP Enabled? · Packet · DSCP QoS · No · No · Yes Yes · Tagged? · No · No · Port QoS · DSCP Settings · 46 high · 34 medium · 24 normal · All others low · 0 normal · 1 low · 2 low · 3 normal · 4 medium · 5 medium · 6 high · 7 high
Page 16 of the Linksys SLM2008 user manual — STP VLAN Bridge Overview
Page 16 · click to enlarge
Page 16

System Priority Bridge priority is used in selecting the root device, root port, and designated port. The device with the highest priority becomes the STA root device. However, if all devices have the same priority, the device with the lowest MAC address will then become the root device. The default value is 32768. The range is 0 to 61440 in steps of 4096.

Bridge ID A unique identifier for this bridge, consisting of the bridge priority and MAC address (where the address is taken from the Switch system).

Hello Time Displays the Hello Time value as defined on the STP > STP Settings screen.

Max Age Displays the Max Age value as defined on the STP > STP Settings screen.

Hello Time Interval (in seconds) at which the root device transmits a configuration message. The default is 2 seconds. The range is 0 to 10 seconds.

Fwd Delay Displays the Forward Delay value as defined on the STP > STP Settings screen.

Topology Displays the topology.

Max Age The maximum time (in seconds) a device can wait without receiving a configuration message before attempting to reconfigure. The default max age is 20 seconds. The range is 6 to 40 seconds.

Root ID The Root ID is displayed here.

STP Port Status

Forward Delay The maximum time (in seconds) this device will wait before changing states (i.e., discarding to learning to forwarding). The default is 15 seconds. The range is 4 to 30 seconds.

STP Status on each interface since the device was last refreshed.

Port The number of the port.

VLAN The VLAN that has been assigned to the port.

STP Port Settings

Path Cost The best path between devices.

Port Displays the port number.

Port Fast Indicates the device is the end for a switch connection.

Enable STP Indicates if STP is enabled on the port.

Port Fast Indicates if Port Fast is enabled on the port. If Port Fast mode is enabled for a port, the Port State is automatically placed in the Forwarding state when the port link is up. Port Fast optimizes the STP protocol convergence.

Port State Indicates if the STP is disabled or enabled on the interface.

Statistics > Statistics Overview

Path Cost The path cost is used to determine the best path between devices. The default value is auto.

You can display standard statistics on network traffic for each port of the device.

From the Statistics Overview screen, you will see the standard statistics for each port of the device. Use the Refresh button to update the statistics.

Click Save Settings to save any changes.

STP > STP Status

Linksys SLM2008 — STP > STP Status diagram (page 16)
Fig. 35 · STP > STP Status

From the STP Status screen, you will see the STP Status for each VLAN Bridge, and for each port.

Linksys SLM2008 — STP > STP Status diagram (page 16)
Fig. 36 · STP > STP Status
Linksys SLM2008 — STP > STP Status diagram (page 16)
Fig. 37 · STP > STP Status

Statistics > Statistics Overview

Port Displays the port that the data applies to.

STP > STP Status

Tx Byte Displays the number of octets transmitted on the port since the device was last refreshed.

STP VLAN Bridge Overview

Tx Frames Displays the number of frames transmitted on the port since the device was last refreshed.

VLAN ID The VLAN ID that has been assigned to the interface.

Rx Bytes Displays the number of octets received on the port since the device was last refreshed.

12 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Page 17 of the Linksys SLM2008 user manual — Multicast > IGMP Settings
Page 17 · click to enlarge
Page 17

Rx Frames Displays the number of frames received on the port since the device was last refreshed.

The ports that have Multicast routers generating IGMP queries

Ports requesting to join a specific Multicast group issue an IGMP report, specifying that Multicast group is accepting members. This results in the creation of the Multicast filtering database.

Tx Errors Displays the number of transmitted packets with errors that have occurred on the port since the device was last refreshed.

Rx Errors Displays the number of received packets with errors that have occurred on the port since the device was last refreshed.

Linksys SLM2008 — Statistics > IGMP Status diagram (page 17)
Fig. 38 · Statistics > IGMP Status

Tx Broadcast Displays the number of good broadcast packets transmitted on the port since the device was last refreshed.

Rx Broadcast Displays the number of good broadcast packets received on the port since the device was last refreshed.

Multicast > IGMP Settings

Statistics > IGMP Status

From the IGMP Status screen, you will see the IGMP Status for each VLAN interface.

Linksys SLM2008 — Statistics > IGMP Status diagram (page 17)
Fig. 39 · Statistics > IGMP Status
Linksys SLM2008 — Statistics > IGMP Status diagram (page 17)
Fig. 40 · Statistics > IGMP Status

Enable IGMP Snooping Indicates if IGMP Snooping is enabled on the device.

Enable Unregistered IP Multicast Flooding Indicates if Unregistered IP Multicast Flooding is enabled on the device.

VLAN ID Displays the VLAN ID number.

Statistics > IGMP Status

Enable IGMP Snooping Indicates if IGMP Snooping is enabled on each VLAN interface.

VLAN ID Displays the VLAN ID .

Querier Indicates the IGMP router is active or idle.

Enable IGMP Querying Indicates if IGMP Querying is enabled on each VLAN interface.

Queries Transmitted Displays the number of queries that have been transmitted.

Click Save Settings to save any changes.

Queries Received Displays the number of queries that have been received.

Admin > Ping

You can use a ping to see if another site on the network can be reached. Ping sends ICMP echo request packets to another node on the network.

v1 Reports Displays the number of IGMP v1 report packets that have been received by the Switch.

v2 Reports Displays the number of IGMP v2 report packets that have been received by the Switch.

Linksys SLM2008 — Admin > Ping diagram (page 17)
Fig. 41 · Admin > Ping

v2 Leaves Displays the number of IGMP v2 leave packets that have been received by the Switch.

Multicast > IGMP Settings

When IGMP Snooping is enabled globally, all IGMP packets are forwarded to the CPU. The CPU analyzes the incoming packets and determines:

The ports that want to join which Multicast groups and issue the IGMP join packet •

13 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

• · Admin > Ping

Page 18 of the Linksys SLM2008 user manual — Admin > Factory Default
Page 18 · click to enlarge
Page 18

Ping Parameters

Click the Restore to Default button, then it will restore the factory default settings to the switch.

Target IP Address Enter the IP Address of the device you want to ping.

Admin > Reboot

Count Set the maximum count to the target IP Address for each attempt.

Restarts the Switch retaining the current configuration settings.

Time Out Set the time out (in seconds) interval if the device does not respond.

Linksys SLM2008 — Admin > Reboot diagram (page 18)
Fig. 42 · Admin > Reboot

Click Save Settings to save any changes.

Admin > Port Mirror

You can mirror traffic from any source port to a target port for real-time analysis. The target port speed should match or exceed source port speed, otherwise traffic may be dropped from the monitor port. The Switch supports only one mirror session.

Click the Reboot button, then it will restart the Switch.

Linksys SLM2008 — Admin > Port Mirror diagram (page 18)
Fig. 43 · Admin > Port Mirror

Admin > Save Configuration

This Save Configuration screen is used to save and retrieve the Switch’s configuration information using your Web browser.

Linksys SLM2008 — Admin > Save Configuration diagram (page 18)
Fig. 44 · Admin > Save Configuration

Admin > Port Mirror

Source Port The port whose traffic will be monitored.

Target Port The port that will mirror the traffic on the source port.

Configuration Upload Select this option to load a previously saved configuration file (.cfg). To do so, perform the following steps:

Click Save Settings to save any changes.

Admin > Factory Default

Click the Browse button.

Locate the appropriate file and click Open.

Restores the Switch’s factory default settings.

Click the Upload button to load the file.

Configuration Backup Select this option to save the Switch settings to a configuration file (.cfg).

Linksys SLM2008 — Admin > Factory Default diagram (page 18)
Fig. 45 · Admin > Factory Default

Click the Save button.

Click Save when prompted to open, save, or cancel.

Select the location where the file should be saved and click Save.

Admin > Factory Default

14 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Admin > Reboot

Page 19 of the Linksys SLM2008 user manual — Admin > Firmware Upgrade
Page 19 · click to enlarge
Page 19

Admin > Firmware Upgrade

Allows you to upgrade the firmware using your Web browser.

Linksys SLM2008 — Admin > Firmware Upgrade diagram (page 19)
Fig. 46 · Admin > Firmware Upgrade

Admin > FIrmware Upgrade

Firmware Upgrade To do so, perform the following steps:

Click the Browse button.

Locate the appropriate file and click Open.

Click the Proceed button to load the file.

15 5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Page 20 of the Linksys SLM2008 user manual — Appendix A
Page 20 · click to enlarge
Page 20

Appendix A

Glossary

Appendix A: Glossary

Baud Indicates the number of signaling elements transmitted each second.

Best Effort Indicates that traffic is assigned to the lowest priority queue, and packet delivery is not guaranteed.

This glossary contains some basic networking terms you may come across when using this product.

Bit A binary digit.

Boot To start a device and cause it to start executing instructions.

WEBFor additional terms, please visit the glossary at www.linksys.com/glossary

Browser An application program that provides a way to look at and interact with all the information on the World Wide Web.

Access Mode Specifies the method by which user access is granted to the system.

Bridge A device that connect two networks. Bridges are hardware specific, however they are protocol independent. Bridges operate at Layer 1 and Layer 2 levels.

Access Point A device that allows wireless-equipped computers and other devices to communicate with a wired network. Also used to expand the range of a wireless network.

Broadcast Domain Devices sets that receive broadcast frames originating from any device within a designated set. Routers bind Broadcast domains, because routers do not forward broadcast frames.

Access Profiles Allows network managers to define profiles and rules for accessing the device. Access to management functions can be limited to user groups, which are defined by the following criteria:

Broadcast Storm An excessive amount of broadcast messages simultaneously transmitted across a network by a single port. Forwarded message responses are heaped onto the network, overloading network resources or causing the network to time out.

Source IP address and/or Source IP subnets.

Burst A packet transmission at faster than normal rates. Bursts are limited in time and only occur under specific conditions.

ACE Filters in Access Control Lists (ACL) that determine which network traffic is forwarded. An ACE is based on the following criteria:

Burst Size Indicates the burst size transmitted at a faster than normal rate.

Byte A unit of data that is usually eight bits long

Cable Modem A device that connects a computer to the cable television network, which in turn connects to the Internet.

CBS (Committed Burst Size) Indicates the maximum number of data bits transmitted within a specific time interval.

ACL (Access Control List) Access Control Lists are used to grant, deny, or limit access devices, features, or applications.

CIR (Committed Information Rate) The data rate is averaged over a minimum time increment.

Class Maps An aspect of Quality of Service system that is comprised of an IP ACL and/or a MAC ACL. Class maps are configured to match packet criteria, and are matched to packets in a first-fit fashion.

Auto-negotiation Allows 10/100 Mbps or 10/100/1000 Mbps Ethernet ports to automatically establish the optimal duplex mode, flow control, and speed.

Back Pressure A mechanism used with Half Duplex mode that enables a port not to receive a message.

Combo Ports A single logical port with two physical connections, including an RJ-45 connection and a SFP connection.

Bandwidth The transmission capacity of a given device or network.

Communities Specifies a group of users which retain the same system access rights.

Bandwidth Assignments Indicates the amount of bandwidth assigned to a specific application, user, and/or interface.

5-Port and 8-Port 10/100/1000 Gigabit Smart Switch with PD and AC Power

Show 17 more labels / short text on this page
• · Ingress interfaces · • · • · Protocol · • · Protocol ID · • · Source Port · • · Destination Port · • · Wildcard Mask · Source IP Address · • · • · Destination IP Address
Page 21 of the Linksys SLM2008 user manual — Appendix A
Page 21 · click to enlarge
Page 21

Appendix A

Glossary

CoS (Class of Service) The 802.1p priority scheme. CoS provides a method for tagging packets with priority information. A CoS value between 0-7 is added to the Layer II header of packets, where zero is the lowest priority and seven is the highest.

Full Duplex The ability of a networking device to receive and transmit data simultaneously.

GARP (General Attributes Registration Protocol) Registers client stations into a multicast domain.

DDNS (Dynamic Domain Name System) Allows the hosting of a website, FTP server, or e-mail server with a fixed domain name (e.g., www.xyz.com) and a dynamic IP address.

Gateway A device that interconnects networks with different, incompatible communications protocols.

GBIC (GigaBit Interface Converter) A hardware module used to attach network devices to fiber-based transmission systems. GBIC converts the serial electrical signals to serial optical signals and vice versa.

Default Gateway A device that forwards Internet traffic from your local area network.

DHCP (Dynamic Host Configuration Protocol) A networking protocol that allows administrators to assign temporary IP addresses to network computers by “leasing” an IP address to a user for a limited amount of time, instead of assigning permanent IP addresses.

GVRP (GARP VLAN Registration Protocol) Registers client stations into a VLANs.

Half Duplex Data transmission that can occur in two directions over a single line, but only one direction at a time.

DHCP Clients An Internet host using DHCP to obtain configuration parameters, such as a network address.

HTTP (HyperText Transport Protocol) The communications protocol used to connect to servers on the World Wide Web.

DHCP Server An Internet host that returns configuration parameters to DHCP clients.

HTTPS (HyperText Transport Protocol Secure) An extension to the standard HTTP protocol that provides confidentiality by encrypting the traffic from the website. By default this protocol uses TCP port 443.

DNS (Domain Name Server) The IP address of your ISP’s server, which translates the names of websites into IP addresses.

Domain A specific name for a network of computers.

ICMP (Internet Control Message Protocol) Allows the gateway or destination host to communicate with the source host. For example, to report a processing error.

Download To receive a file transmitted over a network.

DSL (Digital Subscriber Line) An always-on broadband connection over traditional phone lines.

IGMP (Internet Group Management Protocol) Allows hosts to notify their local switch or router that they want to receive transmissions assigned to a specific multicast group.

DSCP (DiffServ Code Point) Provides a method of tagging IP packets with QoS priority information.

Dynamic IP Address A temporary IP address assigned by a DHCP server.

IP (Internet Protocol) A protocol used to send data over a network.

EIGRP (Enhanced Interior Gateway Routing Protocol) Provides fast convergence, support for variable- length subnet mask, and supports multiple network layer protocols.

IP Address The address used to identify a computer or device on a network.

IPCONFIG A Windows 2000 and XP utility that displays the IP address for a particular networking device.

Encryption Encoding data transmitted in a network.

IPSec (Internet Protocol Security) A VPN protocol used to implement secure exchange of packets at the IP layer.

Ethernet IEEE standard network protocol that specifies how data is placed on and retrieved from a common transmission medium.

ISP (Internet Service Provider) A company that provides access to the Internet.

Firmware The programming code that runs a networking device.

Jumbo Frames Enable transporting identical data in fewer frames. Jumbo Frames reduce overhead, lower processing time, and ensure fewer interrupts.

Flow Control Enables lower speed devices to communicate with higher speed devices. This is implemented by the higher speed device refraining from sending packets.

LAG (Link Aggregated Group) Aggregates ports or VLANs into a single virtual port or VLAN.

FTP (File Transfer Protocol) A protocol used to transfer files over a TCP/IP network.

LAN The computers and networking products that make up your local network.

5-Port and 8-Port 10/100/1000 Gigabit Smart Switch with PD and AC Power

Page 22 of the Linksys SLM2008 user manual — Appendix A
Page 22 · click to enlarge
Page 22

Appendix A

Glossary

MAC (Media Access Control) Address The unique address that a manufacturer assigns to each networking device.

RADIUS (Remote Authentication Dial-In User Service) A protocol that uses an authentication server to control network access.

Mask A filter that includes or excludes certain values, for example parts of an IP address.

RJ-45 (Registered Jack-45) An Ethernet connector that holds up to eight wires.

Mbps (MegaBits Per Second) One million bits per second; a unit of measurement for data transmission.

RMON (Remote Monitoring) Provides network information to be collected from a single workstation.

MD5 (Message Digest 5) An algorithm that produces a 128-bit hash. MD5 is a variation of MD4, and increases MD4 security. MD5 verifies the integrity of the communication and authenticates the origin of the communication.

Router A networking device that connects multiple networks together.

RSTP (Rapid Spanning Tree Protocol) Detects and uses network topologies that allow a faster convergence of the spanning tree, without creating forwarding loops.

MDI (Media Dependent Interface) A cable used for end stations.

Server Any computer whose function in a network is to provide user access to files, printing, communications, and other services.

MDIX (Media Dependent Interface with Crossover) A cable used for hubs and switches.

MIB (Management Information Base) MIBs contain information describing specific aspects of network components.

SMTP (Simple Mail Transfer Protocol) The standard e- mail protocol on the Internet.

SNMP (Simple Network Management Protocol) A widely used network monitoring and control protocol.

Multicast Transmits copies of a single packet to multiple ports.

SSH Secure Shell. A utility that uses strong authentication and secure communications to log in to another computer over a network.

Network A series of computers or devices connected for the purpose of data sharing, storage, and/or transmission between users.

SSL (Secure Socket Layer) Encryption technology for the Internet used to provide secure transactions, such as the transmission of credit card numbers for e-commerce.

NMS (Network Management System) An interface that provides a method of managing a system.

OID (Object Identifier) Used by SNMP to identify managed objects. In the SNMP Manager/Agent network management paradigm, each managed object must have an OID to identify it.

Static IP Address A fixed address assigned to a computer or device that is connected to a network.

STP (Spanning Tree Protocol) Prevents loops in network traffic. The Spanning Tree Protocol (STP) provides tree topography for any arrangement of bridges. STP provides one path between end stations on a network, eliminating loops.

Packet A unit of data sent over a network.

Ping (Packet INternet Groper) An Internet utility used to determine whether a particular IP address is online.

Policing Determines if traffic levels are within a specified profile. Policing manages the maximum traffic rate used to send or receive packets on an interface.

Subnet (Sub-network) Subnets are portions of a network that share a common address component. In TCP/IP networks, devices that share a prefix are part of the same subnet. For example, all devices with a prefix of 157.100.100.100 are part of the same subnet.

Port The connection point on a computer or networking device used for plugging in cables or adapters.

Subnet Mask An address code that determines the size of the network.

Port Mirroring Monitors and mirrors network traffic by forwarding copies of incoming and outgoing packets from one port to a monitoring port.

Switch Filters and forwards packets between LAN segments. Switches support any packet protocol type.

Power over Ethernet (PoE) A technology enabling an Ethernet network cable to deliver both data and power.

TACACS+ (Terminal Access Controller Access Control System Plus) Proprietary Cisco enhancement to Terminal Access Controller Access Control System (TACACS). Provides additional support for authentication, authorization, and accounting.

QoS (Quality of Service) Provides policies that contain sets of filters (rules). QoS allows network managers to decide how and what network traffic is forwarded according to priorities, application types, and source and destination addresses.

5-Port and 8-Port 10/100/1000 Gigabit Smart Switch with PD and AC Power

Page 23 of the Linksys SLM2008 user manual — Appendix A
Page 23 · click to enlarge
Page 23

Appendix A

Glossary

TCP (Transmission Control Protocol) A network protocol for transmitting data that requires acknowledgement from the recipient of data sent.

TCP/IP (Transmission Control Protocol/Internet Protocol) A set of instructions PCs use to communicate over a network.

Telnet A user command and TCP/IP protocol used for accessing remote PCs.

TFTP (Trivial File Transfer Protocol) A version of the TCP/IP FTP protocol that has no directory or password capability.

Throughput The amount of data moved successfully from one node to another in a given time period.

Trunking Link Aggregation. Optimizes port usage by linking a group of ports together to form a single trunk (aggregated groups).

TX Rate Transmission Rate.

UDP (User Data Protocol) Communication protocol that transmits packets but does not guarantee their delivery.

Upgrade To replace existing software or firmware with a newer version.

Upload To transmit a file over a network.

URL (Uniform Resource Locator) The address of a file located on the Internet.

VLAN (Virtual Local Area Networks) Logical subgroups that constitute a Local Area Network (LAN). This is done in software rather than defining a hardware solution.

WAN (Wide Area Network) Networks that cover a large geographical area.

Wildcard Mask Specifies which IP address bits are used, and which bits are ignored. A wild card mask of 255.255.255.255 indicates that no bit is important. A wildcard of 0.0.0.0 indicates that all the bits are important.

For example, if the destination IP address is 149.36.184.198 and the wildcard mask is 255.36.184.00, the first two bits of the IP address are used, while the last two bits are ignored.

5-Port and 8-Port 10/100/1000 Gigabit Smart Switch with PD and AC Power

Page 24 of the Linksys SLM2008 user manual — Other Management
Page 24 · click to enlarge
Page 24

Appendix B

Specifications

Appendix B: Specifications

Security

IEEE 802.1X 802.1X - RADIUS Authentication. MD5 Encryption

Availability

SLM2005

Link Aggregation Link Aggregation using IEEE 802.3ad LACP Up to 5 Ports in up to 2 Groups

Ports 5 RJ-45 Connectors for 10BASE-T/100BASE-TX/ 1000BASE-T Auto MDI/MDI-X Autonegotiate/Manual Setting

Storm Control Broadcast and Multicast

Spanning Tree IEEE 802.1D Spanning Tree

IGMP Snooping IGMP (v1/v2) Snooping Limits Bandwidth-Intensive Video Traffic to only the Requestors. Supports 16 Multicast Groups

Cabling Type UTP CAT 5 or Better for 10BASE-T/100BASE-TX, UTP CAT 5e or Better for 1000BASE-T

QoS

Priority levels 4 Hardware Queues

Scheduling Priority Queuing and Weighted Round Robin (WRR)

PoE

Class of Service Port-Based 802.1p VLAN Priority Based IPv4/v6 IP DSCP Based

802.3af PoE-PD Compatible on Port 1. Supply System Power Without an External Power Adapter

Standards

802.3 10BASE-T Ethernet, 802.3u 100BASE-TX Fast Ethernet, 802.3ab 1000BASE-T Gigabit Ethernet, 802.3z Gigabit Ethernet, 802.3x Flow Control, 802.3 ad LACP,802.3af PoE, 802.1D STP, 802.1Q/p VLAN, 802.1X Port Access Authentication

Performance

Switching Capacity 10 Gbps, Non-Blocking

Forwarding Rate 7.44 Mpps Wire-Speed Performance

Layer 2

MAC table size 8K

Number of VLANs 16 Active VLANs (4096 Range)

Environmental

VLAN Port-Based and 802.1Q Tag-Based VLANs

Dimensions 5.12" x 1.12" x 5.12"

HOL Blocking Head of Line Blocking Prevention

W x H x D 130 x 28.5 x 130 mm

Unit Weight 0.84 lb (0.382 kg)

Management

Power External AC Power Adapter and IEEE 802.3af Compatible PoE‑PD

Web User Interface Built-in Web UI for Easy Browser-Based Configuration

Firmware Upgrade Web Browser Upgrade (HTTP)

Certification FCC Part15 Class B, CE Class A, UL, cUL, CE Mark, CB

Port Mirroring Traffic on a Port can be Mirrored to Another Port for Analysis with a Network Analyzer

Operating Temp. 32 to 104ºF (0 to 40ºC)

Storage Temp. -4 to 158ºF (-20 to 70ºC)

Operating Humidity 10 to 90%

Other Management

Storage Humidity 10 to 95%

RADIUS Port Mirroring DHCP Client PING

5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Specifications · Buttons Reset · LEDs Link/Act, System

Page 25 of the Linksys SLM2008 user manual — Security
Page 25 · click to enlarge
Page 25

Appendix B

Specifications

SLM2008

Availability

Link Aggregation Link Aggregation using IEEE 802.3ad LACP Up to 8 Ports in up to 2 Groups

Specifications

Ports 8 RJ-45 Connectors for 10BASE‑T/100BASE-TX/ 1000BASE-T Auto MDI/MDI-X Autonegotiate/Manual setting

Storm Control Broadcast and Multicast

Spanning Tree IEEE 802.1D Spanning Tree

IGMP Snooping IGMP (v1/v2) Snooping Limits Bandwidth-Intensive Video Traffic to Only the Requestors. Supports 16 Multicast Groups.

Cabling Type UTP CAT 5 or Better for 10BASE-T/100BASE-TX, UTP CAT 5e or Better for 1000BASE-T

QoS

Priority levels 4 Hardware Queues

Scheduling Priority Queuing and Weighted Round Robin (WRR)

PoE

Class of Service Port-Based 802.1p VLAN Priority Based IPv4/v6 IP DSCP Based

802.3af PoE-PD Compatible on Port 1. Supply System Power Without an External Power Adapter

Standards 802.3 10BASE-T Ethernet, 802.3u 100BASE-TX Fast Ethernet, 802.3ab 1000BASE-T Gigabit Ethernet, 802.3z Gigabit Ethernet, 802.3x Flow Control, 802.3 ad LACP,802.3af PoE, 802.1D STP, 802.1Q/p VLAN, 802.1X Port Access Authentication

Performance

Switching Capacity 16 Gbps, Non-Blocking

Forwarding Rate 11.9 Mpps Wire-Speed Performance

Layer 2

MAC table size 8K

Number of VLANs 16 Active VLANs (4096 Range)

Environmental

VLAN Port-Based and 802.1Q Tag-Based VLANs

Dimensions 5.12" x 1.12" x 5.12"

W x H x D 130 x 28.5 x 130 mm

HOL Blocking Head of Line Blocking Prevention

Unit Weight 0.91 lb (0.4139 kg)

Power External AC Power Adapter and IEEE 802.3af Compatible PoE-PD

Management

Web User Interface Built-in Web UI for Easy Browser-Based Configuration

Certification FCC Part15 Class B, CE Class A, UL, cUL, CE Mark, CB

Firmware Upgrade Web Browser Upgrade (HTTP)

Operating Temp. 32 to 104ºF (0 to 40ºC)

Port Mirroring Traffic on a Port can be Mirrored to Another Port for Analysis with a Network Analyzer

Storage Temp. -4 to 158ºF (-20 to 70ºC)

Operating Humidity 10 to 90%

Storage Humidity 10 to 95%

Other Management

RADIUS Port Mirroring DHCP Client PING

Security

IEEE 802.1X 802.1X - RADIUS Authentication. MD5 Encryption

5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Buttons Reset · LEDs Link/Act, System

Page 26 of the Linksys SLM2008 user manual — Limited Warranty
Page 26 · click to enlarge
Page 26

Appendix C

Warranty and Regulatory Information

Appendix C: Warranty and Regulatory Information

TO THE EXTENT NOT PROHIBITED BY LAW, IN NO EVENT WILL LINKSYS BE LIABLE FOR ANY LOST DATA, REVENUE OR PROFIT, OR FOR SPECIAL, INDIRECT, CONSEQUENTIAL, INCIDENTAL OR PUNITIVE DAMAGES, REGARDLESS OF THE THEORY OF LIABILITY (INCLUDING NEGLIGENCE), ARISING OUT OF OR RELATED TO THE USE OF OR INABILITY TO USE THE PRODUCT (INCLUDING ANY SOFTWARE), EVEN IF LINKSYS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT WILL LINKSYS’ LIABILITY EXCEED THE AMOUNT PAID BY YOU FOR THE PRODUCT. The foregoing limitations will apply even if any warranty or remedy provided under this Agreement fails of its essential purpose. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to You.

Limited Warranty

Linksys warrants to You that, for a period of five years (the “Warranty Period”), your Linksys Product will be substantially free of defects in materials and workmanship under normal use. Your exclusive remedy and Linksys’ entire liability under this warranty will be for Linksys at its option to repair or replace the Product or refund Your purchase price less any rebates. This limited warranty extends only to the original purchaser.

Please direct all inquiries to: Linksys, P.O. Box 18558, Irvine, CA 92623.

If the Product proves defective during the Warranty Period call Linksys Technical Support in order to obtain a Return Authorization Number, if applicable. BE SURE TO HAVE YOUR PROOF OF PURCHASE ON HAND WHEN CALLING. If You are requested to return the Product, mark the Return Authorization Number clearly on the outside of the package and include a copy of your original proof of purchase. RETURN REQUESTS CANNOT BE PROCESSED WITHOUT PROOF OF PURCHASE. You are responsible for shipping defective Products to Linksys. Linksys pays for UPS Ground shipping from Linksys back to You only. Customers located outside of the United States of America and Canada are responsible for all shipping and handling charges.

ALL IMPLIED WARRANTIES AND CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THE WARRANTY PERIOD. ALL OTHER EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF NON- INFRINGEMENT, ARE DISCLAIMED. Some jurisdictions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to You. This warranty gives You specific legal rights, and You may also have other rights which vary by jurisdiction.

This warranty does not apply if the Product (a) has been altered, except by Linksys, (b) has not been installed, operated, repaired, or maintained in accordance with instructions supplied by Linksys, or (c) has been subjected to abnormal physical or electrical stress, misuse, negligence, or accident. In addition, due to the continual development of new techniques for intruding upon and attacking networks, Linksys does not warrant that the Product will be free of vulnerability to intrusion or attack.

5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Page 27 of the Linksys SLM2008 user manual — Industry Canada Statement
Page 27 · click to enlarge
Page 27

Appendix C

Warranty and Regulatory Information

FCC Statement

Règlement d’Industry Canada

This product has been tested and complies with the specifications for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used according to the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which is found by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Cet appareil est conforme à la norme NMB003 d’Industrie Canada.

Le fonctionnement est soumis aux conditions suivantes :

Ce périphérique ne doit pas causer d’interférences;

Ce périphérique doit accepter toutes les interférences reçues, y compris celles qui risquent d’entraîner un fonctionnement indésirable.

Reorient or relocate the receiving antenna

Increase the separation between the equipment or devices

Connect the equipment to an outlet other than the receiver’s

Consult a dealer or an experienced radio/TV technician for assistance

Safety Notices

Do not use this product near water, for example, in a wet basement or near a swimming pool.

Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.

Industry Canada Statement

This device complies with Industry Canada ICES-003 rule.

Operation is subject to the following two conditions:

This device may not cause interference and

This device must accept any interference, including interference that may cause undesired operation of the device.

5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Show 4 more labels / short text on this page
• · • · • · •
Page 28 of the Linksys SLM2008 user manual — Appendix C
Page 28 · click to enlarge
Page 28

Appendix C

Warranty and Regulatory Information

User Information for Consumer Products Covered by EU Directive 2002/96/EC on Waste Electric and Electronic Equipment (WEEE)

Ceština (Czech) - Informace o ochraně životního prostředí pro zákazníky v zemích Evropské unie Evropská směrnice 2002/96/ES zakazuje, aby zařízení označené tímto symbolem na produktu anebo na obalu bylo likvidováno s netříděným komunálním odpadem. Tento symbol udává, že daný produkt musí být likvidován odděleně od běžného komunálního odpadu. Odpovídáte za likvidaci tohoto produktu a dalších elektrických a elektronických zařízení prostřednictvím určených sběrných míst stanovených vládou nebo místními úřady. Správná likvidace a recyklace pomáhá předcházet potenciálním negativním dopadům na životní prostředí a lidské zdraví. Podrobnější informace o likvidaci starého vybavení si laskavě vyžádejte od místních úřadů, podniku zabývajícího se likvidací komunálních odpadů nebo obchodu, kde jste produkt zakoupili.

This document contains important information for users with regards to the proper disposal and recycling of Linksys products. Consumers are required to comply with this notice for all electronic products bearing the following symbol:

Dansk (Danish) - Miljøinformation for kunder i EU EU-direktiv 2002/96/EF kræver, at udstyr der bærer dette symbol

på produktet og/eller emballagen ikke må bortskaffes som usorteret kommunalt affald. Symbolet betyder, at dette produkt skal bortskaffes adskilt fra det almindelige husholdningsaffald. Det er dit ansvar at bortskaffe dette og andet elektrisk og elektronisk udstyr via bestemte indsamlingssteder udpeget af staten eller de lokale myndigheder. Korrekt bortskaffelse og genvinding vil hjælpe med til at undgå mulige skader for miljøet og menneskers sundhed. Kontakt venligst de lokale myndigheder, renovationstjenesten eller den butik, hvor du har købt produktet, angående mere detaljeret information om bortskaffelse af dit gamle udstyr.

English - Environmental Information for Customers in the European Union European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about the disposal of your old equipment, please contact your local authorities, waste disposal service, or the shop where you purchased the product.

Deutsch (German) - Umweltinformation für Kunden innerhalb der Europäischen Union Die Europäische Richtlinie 2002/96/EC verlangt, dass technische Ausrüstung, die direkt am Gerät und/oder an der Verpackung mit diesem Symbol versehen ist , nicht zusammen mit unsortiertem Gemeindeabfall entsorgt werden darf. Das Symbol weist darauf hin, dass das Produkt von regulärem Haushaltmüll getrennt entsorgt werden sollte. Es liegt in Ihrer Verantwortung, dieses Gerät und andere elektrische und elektronische Geräte über die dafür zuständigen und von der Regierung oder örtlichen Behörden dazu bestimmten Sammelstellen zu entsorgen. Ordnungsgemäßes Entsorgen und Recyceln trägt dazu bei, potentielle negative Folgen für Umwelt und die menschliche Gesundheit zu vermeiden. Wenn Sie weitere Informationen zur Entsorgung Ihrer Altgeräte benötigen, wenden Sie sich bitte an die örtlichen Behörden oder städtischen Entsorgungsdienste oder an den Händler, bei dem Sie das Produkt erworben haben.

Български (Bulgarian) - Информация относно опазването на околната среда за потребители в Европейския съюз Европейска директива 2002/96/EC изисква уредите, носещи този символ върху изделието и/или опаковката му, да не се изхвърля т с несортирани битови отпадъци. Символът обозначава, че изделието трябва да се изхвърля отделно от сметосъбирането на обикновените битови отпадъци. Ваша е отговорността този и другите електрически и електронни уреди да се изхвърлят в предварително определени от държавните или общински органи специализирани пунктове за събиране. Правилното изхвърляне и рециклиране ще спомогнат да се предотвратят евентуални вредни за околната среда и здравето на населението последствия. За по-подробна информация относно изхвърлянето на вашите стари уреди се обърнете към местните власти, службите за сметосъбиране или магазина, от който сте закупили уреда.

5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Page 29 of the Linksys SLM2008 user manual — Appendix C
Page 29 · click to enlarge
Page 29

Appendix C

Warranty and Regulatory Information

Eesti (Estonian) - Keskkonnaalane informatsioon Euroopa Liidus asuvatele klientidele Euroopa Liidu direktiivi 2002/96/EÜ nõuete kohaselt on seadmeid, millel on tootel või pakendil käesolev sümbol , keelatud kõrvaldada koos sorteerimata olmejäätmetega. See sümbol näitab, et toode tuleks kõrvaldada eraldi tavalistest olmejäätmevoogudest. Olete kohustatud kõrvaldama käesoleva ja ka muud elektri- ja elektroonikaseadmed riigi või kohalike ametiasutuste poolt ette nähtud kogumispunktide kaudu. Seadmete korrektne kõrvaldamine ja ringlussevõtt aitab vältida võimalikke negatiivseid tagajärgi keskkonnale ning inimeste tervisele. Vanade seadmete kõrvaldamise kohta täpsema informatsiooni saamiseks võtke palun ühendust kohalike ametiasutustega, jäätmekäitlusfirmaga või kauplusega, kust te toote ostsite.

Français (French) - Informations environnementales pour les clients de l’Union européenne La directive européenne 2002/96/CE exige que l’équipement sur lequel est apposé ce symbole sur le produit et/ou son emballage ne soit pas jeté avec les autres ordures ménagères. Ce symbole indique que le produit doit être éliminé dans un circuit distinct de celui pour les déchets des ménages. Il est de votre responsabilité de jeter ce matériel ainsi que tout autre matériel électrique ou électronique par les moyens de collecte indiqués par le gouvernement et les pouvoirs publics des collectivités territoriales. L’élimination et le recyclage en bonne et due forme ont pour but de lutter contre l’impact néfaste potentiel de ce type de produits sur l’environnement et la santé publique. Pour plus d’informations sur le mode d’élimination de votre ancien équipement, veuillez prendre contact avec les pouvoirs publics locaux, le service de traitement des déchets, ou l’endroit où vous avez acheté le produit.

Español (Spanish) - Información medioambiental para clientes de la Unión Europea La Directiva 2002/96/CE de la UE exige que los equipos que lleven este símbolo en el propio aparato y/o en su embalaje no deben eliminarse junto con otros residuos urbanos no seleccionados. El símbolo indica que el producto en cuestión debe separarse de los residuos domésticos convencionales con vistas a su eliminación. Es responsabilidad suya desechar este y cualesquiera otros aparatos eléctricos y electrónicos a través de los puntos de recogida que ponen a su disposición el gobierno y las autoridades locales. Al desechar y reciclar correctamente estos aparatos estará contribuyendo a evitar posibles consecuencias negativas para el medio ambiente y la salud de las personas. Si desea obtener información más detallada sobre la eliminación segura de su aparato usado, consulte a las autoridades locales, al servicio de recogida y eliminación de residuos de su zona o pregunte en la tienda donde adquirió el producto.

Italiano (Italian) - Informazioni relative all’ambiente per i clienti residenti nell’Unione Europea La direttiva europea 2002/96/EC richiede che le apparecchiature contrassegnate con questo simbolo sul prodotto e/o sull’imballaggio non siano smaltite insieme ai rifiuti urbani non differenziati. Il simbolo indica che questo prodotto non deve essere smaltito insieme ai normali rifiuti domestici. È responsabilità del proprietario smaltire sia questi prodotti sia le altre apparecchiature elettriche ed elettroniche mediante le specifiche strutture di raccolta indicate dal governo o dagli enti pubblici locali. Il corretto smaltimento ed il riciclaggio aiuteranno a prevenire conseguenze potenzialmente negative per l’ambiente e per la salute dell’essere umano. Per ricevere informazioni più dettagliate circa lo smaltimento delle vecchie apparecchiature in Vostro possesso, Vi invitiamo a contattare gli enti pubblici di competenza, il servizio di smaltimento rifiuti o il negozio nel quale avete acquistato il prodotto.

ξλληνικά (Greek) - Στοιχεία περιβαλλοντικής προστασίας για πελάτες εντός της Ευρωπαϊκής Ένωσης Η Κοινοτική Οδηγία 2002/96/EC απαιτεί ότι ο εξοπλισμός ο οποίος φέρει αυτό το σύμβολο στο προϊόν και/ή στη συσκευασία του δεν πρέπει να απορρίπτεται μαζί με τα μικτά κοινοτικά απορρίμματα. Το σύμβολο υποδεικνύει ότι αυτό το προϊόν θα πρέπει να απορρίπτεται ξεχωριστά από τα συνήθη οικιακά απορρίμματα. Είστε υπεύθυνος για την απόρριψη του παρόντος και άλλου ηλεκτρικού και ηλεκτρονικού εξοπλισμού μέσω των καθορισμένων εγκαταστάσεων συγκέντρωσης απορριμμάτων οι οποίες παρέχονται από το κράτος ή τις αρμόδιες τοπικές αρχές. Η σωστή απόρριψη και ανακύκλωση συμβάλλει στην πρόληψη πιθανών αρνητικών συνεπειών για το περιβάλλον και την υγεία. Για περισσότερες πληροφορίες σχετικά με την απόρριψη του παλιού σας εξοπλισμού, παρακαλώ επικοινωνήστε με τις τοπικές αρχές, τις υπηρεσίες απόρριψης ή το κατάστημα από το οποίο αγοράσατε το προϊόν.

Latviešu valoda (Latvian) - Ekoloģiska informācija klientiem Eiropas Savienības jurisdikcijā Direktīvā 2002/96/EK ir prasība, ka aprīkojumu, kam pievienota zīme uz paša izstrādājuma vai uz tā iesaiņojuma, nedrīkst izmest nešķirotā veidā kopā ar komunālajiem atkritumiem (tiem, ko rada vietēji iedzīvotāji un uzņēmumi). Šī zīme nozīmē to, ka šī ierīce ir jāizmet atkritumos tā, lai tā nenonāktu kopā ar parastiem mājsaimniecības atkritumiem. Jūsu pienākums ir šo un citas elektriskas un elektroniskas ierīces izmest atkritumos, izmantojot īpašus atkritumu savākšanas veidus un līdzekļus, ko nodrošina valsts un pašvaldību iestādes. Ja izmešana atkritumos un pārstrāde tiek veikta pareizi, tad mazinās iespējamais kaitējums dabai un cilvēku veselībai. Sīkākas ziņas par novecojuša aprīkojuma izmešanu atkritumos jūs varat saņemt vietējā pašvaldībā, atkritumu savākšanas dienestā, kā arī veikalā, kur iegādājāties šo izstrādājumu.

5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Page 30 of the Linksys SLM2008 user manual — Appendix C
Page 30 · click to enlarge
Page 30

Appendix C

Warranty and Regulatory Information

Lietuvškai (Lithuanian) - Aplinkosaugos informacija, skirta Europos Sąjungos vartotojams Europos direktyva 2002/96/EC numato, kad įrangos, kuri ir kurios pakuotė yra pažymėta šiuo simboliu (įveskite simbolį), negalima šalinti kartu su nerūšiuotomis komunalinėmis atliekomis. Šis simbolis rodo, kad gaminį reikia šalinti atskirai nuo bendro buitinių atliekų srauto. Jūs privalote užtikrinti, kad ši ir kita elektros ar elektroninė įranga būtų šalinama per tam tikras nacionalinės ar vietinės valdžios nustatytas atliekų rinkimo sistemas. Tinkamai šalinant ir perdirbant atliekas, bus išvengta galimos žalos aplinkai ir žmonių sveikatai. Daugiau informacijos apie jūsų senos įrangos šalinimą gali pateikti vietinės valdžios institucijos, atliekų šalinimo tarnybos arba parduotuvės, kuriose įsigijote tą gaminį.

Nederlands (Dutch) - Milieu-informatie voor klanten in de Europese Unie De Europese Richtlijn 2002/96/EC schrijft voor dat apparatuur die is voorzien van dit symbool op het product of de verpakking, niet mag worden ingezameld met niet-gescheiden huishoudelijk afval. Dit symbool geeft aan dat het product apart moet worden ingezameld. U bent zelf verantwoordelijk voor de vernietiging van deze en andere elektrische en elektronische apparatuur via de daarvoor door de landelijke of plaatselijke overheid aangewezen inzamelingskanalen. De juiste vernietiging en recycling van deze apparatuur voorkomt mogelijke negatieve gevolgen voor het milieu en de gezondheid. Voor meer informatie over het vernietigen van uw oude apparatuur neemt u contact op met de plaatselijke autoriteiten of afvalverwerkingsdienst, of met de winkel waar u het product hebt aangeschaft.

Malti (Maltese) - Informazzjoni Ambjentali għal Klijenti fl-Unjoni Ewropea Id-Direttiva Ewropea 2002/96/KE titlob li t-tagħmir li jkun fih is- simbolu fuq il-prodott u/jew fuq l-ippakkjar ma jistax jintrema ma’ skart muniċipali li ma ġiex isseparat. Is-simbolu jindika li dan il-prodott għandu jintrema separatament minn ma’ l- iskart domestiku regolari. Hija responsabbiltà tiegħek li tarmi dan it-tagħmir u kull tagħmir ieħor ta’ l-elettriku u elettroniku permezz ta’ faċilitajiet ta’ ġbir appuntati apposta mill-gvern jew mill-awtoritajiet lokali. Ir-rimi b’mod korrett u r-riċiklaġġ jgħin jipprevjeni konsegwenzi negattivi potenzjali għall-ambjent u għas-saħħa tal-bniedem. Għal aktar informazzjoni dettaljata dwar ir-rimi tat-tagħmir antik tiegħek, jekk jogħġbok ikkuntattja lill-awtoritajiet lokali tiegħek, is-servizzi għar-rimi ta’ l-iskart, jew il-ħanut minn fejn xtrajt il-prodott.

Norsk (Norwegian) - Miljøinformasjon for kunder i EU EU-direktiv 2002/96/EF krever at utstyr med følgende symbol

avbildet på produktet og/eller pakningen, ikke må kastes sammen med usortert avfall. Symbolet indikerer at dette produktet skal håndteres atskilt fra ordinær avfallsinnsamling for husholdningsavfall. Det er ditt ansvar å kvitte deg med dette produktet og annet elektrisk og elektronisk avfall via egne innsamlingsordninger slik myndighetene eller kommunene bestemmer. Korrekt avfallshåndtering og gjenvinning vil være med på å forhindre mulige negative konsekvenser for miljø og helse. For nærmere informasjon om håndtering av det kasserte utstyret ditt, kan du ta kontakt med kommunen, en innsamlingsstasjon for avfall eller butikken der du kjøpte produktet.

Magyar (Hungarian) - Környezetvédelmi információ az európai uniós vásárlók számára A 2002/96/EC számú európai uniós irányelv megkívánja, hogy azokat a termékeket, amelyeken, és/vagy amelyek csomagolásán az alábbi címke megjelenik, tilos a többi szelektálatlan lakossági hulladékkal együtt kidobni. A címke azt jelöli, hogy az adott termék kidobásakor a szokványos háztartási hulladékelszállítási rendszerektõl elkülönített eljárást kell alkalmazni. Az Ön felelõssége, hogy ezt, és más elektromos és elektronikus berendezéseit a kormányzati vagy a helyi hatóságok által kijelölt gyűjtõredszereken keresztül számolja fel. A megfelelõ hulladékfeldolgozás segít a környezetre és az emberi egészségre potenciálisan ártalmas negatív hatások megelõzésében. Ha elavult berendezéseinek felszámolásához további részletes információra van szüksége, kérjük, lépjen kapcsolatba a helyi hatóságokkal, a hulladékfeldolgozási szolgálattal, vagy azzal üzlettel, ahol a terméket vásárolta.

Polski (Polish) - Informacja dla klientów w Unii Europejskiej o przepisach dotyczących ochrony środowiska Dyrektywa Europejska 2002/96/EC wymaga, aby sprzęt oznaczony symbolem znajdującym się na produkcie i/lub jego opakowaniu nie był wyrzucany razem z innymi niesortowanymi odpadami komunalnymi. Symbol ten wskazuje, że produkt nie powinien być usuwany razem ze zwykłymi odpadami z gospodarstw domowych. Na Państwu spoczywa obowiązek wyrzucania tego i innych urządzeń elektrycznych oraz elektronicznych w punktach odbioru wyznaczonych przez władze krajowe lub lokalne. Pozbywanie się sprzętu we właściwy sposób i jego recykling pomogą zapobiec potencjalnie negatywnym konsekwencjom dla środowiska i zdrowia ludzkiego. W celu uzyskania szczegółowych informacji o usuwaniu starego sprzętu, prosimy zwrócić się do lokalnych władz, służb oczyszczania miasta lub sklepu, w którym produkt został nabyty.

5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Page 31 of the Linksys SLM2008 user manual — Appendix C
Page 31 · click to enlarge
Page 31

Appendix C

Warranty and Regulatory Information

Português (Portuguese) - Informação ambiental para clientes da União Europeia A Directiva Europeia 2002/96/CE exige que o equipamento que exibe este símbolo no produto e/ou na sua embalagem não seja eliminado junto com os resíduos municipais não separados. O símbolo indica que este produto deve ser eliminado separadamente dos resíduos domésticos regulares. É da sua responsabilidade eliminar este e qualquer outro equipamento eléctrico e electrónico através das instalações de recolha designadas pelas autoridades governamentais ou locais. A eliminação e reciclagem correctas ajudarão a prevenir as consequências negativas para o ambiente e para a saúde humana. Para obter informações mais detalhadas sobre a forma de eliminar o seu equipamento antigo, contacte as autoridades locais, os serviços de eliminação de resíduos ou o estabelecimento comercial onde adquiriu o produto.

Slovenčina (Slovene) - Okoljske informacije za stranke v Evropski uniji Evropska direktiva 2002/96/EC prepoveduje odlaganje opreme, označene s tem simbolom – na izdelku in/ali na embalaži – med običajne, nerazvrščene odpadke. Ta simbol opozarja, da je treba izdelek odvreči ločeno od preostalih gospodinjskih odpadkov. Vaša odgovornost je, da to in preostalo električno in elektronsko opremo odnesete na posebna zbirališča, ki jih določijo državne ustanove ali lokalna uprava. S pravilnim odlaganjem in recikliranjem boste preprečili morebitne škodljive vplive na okolje in zdravje ljudi. Če želite izvedeti več o odlaganju stare opreme, se obrnite na lokalno upravo, odpad ali trgovino, kjer ste izdelek kupili.

Suomi (Finnish) - Ympäristöä koskevia tietoja EU- alueen asiakkaille EU-direktiivi 2002/96/EY edellyttää, että jos laitteistossa on tämä symboli itse tuotteessa ja/tai sen pakkauksessa, laitteistoa ei saa hävittää lajittelemattoman yhdyskuntajätteen mukana. Symboli merkitsee sitä, että tämä tuote on hävitettävä erillään tavallisesta kotitalousjätteestä. Sinun vastuullasi on hävittää tämä elektroniikkatuote ja muut vastaavat elektroniikkatuotteet viemällä tuote tai tuotteet viranomaisten määräämään keräyspisteeseen. Laitteiston oikea hävittäminen estää mahdolliset kielteiset vaikutukset ympäristöön ja ihmisten terveyteen. Lisätietoja vanhan laitteiston oikeasta hävitystavasta saa paikallisilta viranomaisilta, jätteenhävityspalvelusta tai siitä myymälästä, josta ostit tuotteen.

Română (Romanian) - Informaţii de mediu pentru clienţii din Uniunea Europeană Directiva europeană 2002/96/CE impune ca echipamentele care prezintă acest simbol pe produs şi/sau pe ambalajul acestuia să nu fie casate împreună cu gunoiul menajer municipal. Simbolul indică faptul că acest produs trebuie să fie casat separat de gunoiul menajer obişnuit. Este responsabilitatea dvs. să casaţi acest produs şi alte echipamente electrice şi electronice prin intermediul unităţilor de colectare special desemnate de guvern sau de autorităţile locale. Casarea şi reciclarea corecte vor ajuta la prevenirea potenţialelor consecinţe negative asupra sănătăţii mediului şi a oamenilor. Pentru mai multe informaţii detaliate cu privire la casarea acestui echipament vechi, contactaţi autorităţile locale, serviciul de salubrizare sau magazinul de la care aţi achiziţionat produsul.

Svenska (Swedish) - Miljöinformation för kunder i Europeiska unionen Det europeiska direktivet 2002/96/EC kräver att utrustning med denna symbol på produkten och/eller förpackningen inte får kastas med osorterat kommunalt avfall. Symbolen visar att denna produkt bör kastas efter att den avskiljts från vanligt hushållsavfall. Det faller på ditt ansvar att kasta denna och annan elektrisk och elektronisk utrustning på fastställda insamlingsplatser utsedda av regeringen eller lokala myndigheter. Korrekt kassering och återvinning skyddar mot eventuella negativa konsekvenser för miljön och personhälsa. För mer detaljerad information om kassering av din gamla utrustning kontaktar du dina lokala myndigheter, avfallshanteringen eller butiken där du köpte produkten.

Slovenčina (Slovak) - Informácie o ochrane životného prostredia pre zákazníkov v Európskej únii Podľa európskej smernice 2002/96/ES zariadenie s týmto symbolom na produkte a/alebo jeho balení nesmie byť likvidované spolu s netriedeným komunálnym odpadom. Symbol znamená, že produkt by sa mal likvidovať oddelene od bežného odpadu z domácností. Je vašou povinnosťou likvidovať toto i ostatné elektrické a elektronické zariadenia prostredníctvom špecializovaných zberných zariadení určených vládou alebo miestnymi orgánmi. Správna likvidácia a recyklácia pomôže zabrániť prípadným negatívnym dopadom na životné prostredie a zdravie ľudí. Ak máte záujem o podrobnejšie informácie o likvidácii starého zariadenia, obráťte sa, prosím, na miestne orgány, organizácie zaoberajúce sa likvidáciou odpadov alebo obchod, v ktorom ste si produkt zakúpili.

WEBFor additional information, please visit www.linksys.com

5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Page 32 of the Linksys SLM2008 user manual — 7052310A-RR
Page 32 · click to enlarge
Page 32

Appendix D

Contact Information

Appendix D: Contact Information

Website http://www.linksys.com

E-Mail support@linksys.com

FTP Site ftp.linksys.com

Advice Line 800-546-5797 (LINKSYS)

RMA (Return Merchandise Authorization) 949-823-3000

7052310A-RR

5-Port and 8-Port 10/100/1000 Gigabit Smart Switches with PD and AC Power

Linksys Contact Information · Support 800-326-7114 · Fax 949-823-3002

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Linksys SLM2008

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Linksys SLM2008

Be the first to ask — other owners or our team will answer.

Original document

Linksys SLM2008 manual PDF

32 pages·2.5 MB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…