Step 2: Determine the site for installation of the solar panel. It is important to install the solar panel facing the path of the sun where full sun will strike its face throughout the day. The solar panel cannot be shaded out or obstructed by trees, bushes, buildings etc for any part of the day. The curved pipe (D) maintains the proper angle to the sun. Secure the solar panel assembly to a wooden post or fence using two pipe clamps (C) and #2 lag screws (B) as shown in the illustration. If your fence post is metal, you will need alternative hardware not provided, (i.e. U-clamps or metal screws).
Compatible with all Linear APeX™ enabled DC
Slide and Swing Gate Operators.

Step 3: All Linear APeX powered gate operators have a POWER IN terminal on their control boards marked 24V SOLAR PANEL for connecting the solar panel wires (See illustration). Feed the free end of the solar panel wires into the control box and attach them to the 24V SOLAR PANEL terminals APeX control board. The RED solar panel wire goes to the (+) POSITIVE Solar terminal and the BLACK solar panel wire goes to the (–) NEGATIVE Solar terminal. See diagram below.
RED
Parts Included:
F
D
A. Solar Panel B. Lag Screws (4) C. Pipe Clamp (4) D. Curved Pipe E. 1/4” Nuts (4) F. 1/4” x 1/2” Bolt (4) G. Wire Nuts H. Compass
H
A
For more information on Linear’s full line of gate operators, residential and commercial door operators, radio, and access controls visit our website at www.linearcorp.com

Solar Panels connect in PARALLEL
3. For optimal effi ciency, wipe the face of the panel frequently with a soft, damp cloth. The output of the Solar Panel is variable during the day depending on the intensity of the sun and the angle of the rays striking the panel. The output may vary from a few millivolts to as much as 44 volts. To check the output, simply disconnect the solar panel leads from the control board and connect them directly to a dc voltmeter. In bright sunlight the panel output should read at least 34 volts dc at approximately 300mA.
BLACK BLACK
attach BLACK to negative (–) solar terminal on control board attach RED to positive (+) solar terminal on control board
Use the table and map to determine the number of operational cycles* per day to expect in your area, using 10 to 30 Watts of charging power. Figures are shown for winter (minimum sunlight), on a maximum loaded gate and do not account for the use of any accessory items. Accessories will draw additional power from the battery; the more accessories you connect, the more power your system will require. *An operational cycle is one full opening and closing of the gate. *Number of openings per day will depend on the length, weight, hardware and environmental conditions.
Attach BLACK to negative (–) solar terminal on control board attach RED to positive (+) solar terminal on control board.
LRA Estimated Gate Cycles Per Day
Zone 1
Zone 2 Zone 3
Zone 3 Zone 3
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340
www.linearcorp.com