EN
Linear logo
Official user manual

Linear Personal Emergency Reporting System (PERS-4200 Series)

44 pages·1.6 MB·Medical Alarms·PDF·ENDEFRITNLJA
Linear Personal Emergency Reporting System (PERS-4200 Series)
Table of Contents 58 sections BY · I NSTALLATION & O PERATION I NSTRUCTIONS · Important PERS Installation Warnings · 3. Console Connections · … ShowHide
Page 1 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — BY
Page 1 · click to enlarge
Page 1
Linear Personal Emergency Reporting System (PERS-4200 Series) — BY diagram (page 1)
Fig. 1

BY

BY

I NSTALLATION & O PERATION I NSTRUCTIONS

USA & Canada (800) 421-1587 & (800) 392-0123

(760) 438-7000 - Toll Free FAX (800) 468-1340

www.linearcorp.com

Page 2 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — Important PERS Installation Warnings
Page 2 · click to enlarge
Page 2

Important PERS Installation Warnings

✔Be sure and test the system weekly.

✔This electronic product and its backup battery are not to be thrown away with everyday waste. It is your responsibility to dispose of electrical and electronics equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment (W.E.E.E.). The separate collection and recycling of your waste electrical and electronic equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city offi ce, or your household waste disposal service, or the shop where you purchased the product.

Instruct the end-user regarding the importance of periodically testing the system.

✔IMPORTANT – For telephone connection,

connect the “LINE” jack to the household telephone line wall jack, as described in the installation instructions. The Console will not be able to report over the telephone if this connection is not made.

✔The Console must be connected to a

Managed Facilities Voice Network (MFVN) that will remain in operation during local power outages.

✔The Console must be located centrally in

the installation area relative to where the personal emergency transmitter(s) will be carried and/or activated.

✔Locating the Console adjacent to large

metal objects may change or reduce the effective radio range of personal emergency transmitters used with the Console.

✔Electrical interference can reduce the

effective radio range of the Console. Do not operate any electrical appliances or electrical noise generating devices (fl uorescent lamps, motors, etc.) near the Console.

✔The Console should be kept free of dust

and moisture.

✔Do not use ammonia, benzene, thinner,

or similar solvents, or abrasive powder to clean the housing of the Console or the emergency transmitter(s). Clean units by wiping with a damp, soft cloth.

✔The Console should not be located where

sunlight will shine direct on it.

✔Avoid locating the Console in extremely

hot or cold locations.

Page 3 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — Important PERS Installation Warnings
Page 3 · click to enlarge
Page 3
Page 3 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — Important PERS Installation Warnings
Page 4 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — Important PERS Installation Warnings
Page 4 · click to enlarge
Page 4
1. Product Description The PERS-4200 Console is a UL Listed supervised wireless emergency reporting product designed for personal emergency reporting applications. The table-top Console provides “pushbutton” emergency assistance to anyone who desires additional security and peace of mind.

Voice Prompts A built-in digital voice synthesizer can speak voice prompts in English, or Spanish to guide the user during operation, and guide the installer during programming.

✓ NOTECheck the Linear Web site for Console fi rmware upgrades that

may support additional languages.

Linear Personal Emergency Reporting System (PERS-4200 Series) — Important PERS Installation Warnings diagram (page 4)
Fig. 2 · Important PERS Installation Warnings

Language specifi c Console button labels are supplied for alternate language use. For the visually impaired, a braille label is also supplied to identify the Console’s buttons. Power Supply Powered by a low voltage plug-in power supply, the Console includes a rechargeable backup battery for operation during AC power outages. Programming The Console must be confi gured before use. Linear’s RA4200 software confi gures the Console remotely through the standard telephone line, or locally through the Console’s USB port, or through the optional cellular module via the Linear Voice Gateway. In addition, limited programming can be done remotely through the standard telephone line with a touch-tone telephone.

The Console receives signals from up to 16 Linear wireless transmitters (called “sensors”). Activating a transmitter causes the Console’s digital communicator to send the appropriate alarm report to the central monitoring station via a standard land-line telephone connection or through the optional cellular wireless communications module. In addition to the Central Station report, voice prompts sound from the Console and multi-color indicator rings around the Console’s buttons display status. The emergency alarm can be triggered by the HELP button on the Console or with a wireless transmitter. The fi re alarm can be triggered by wireless smoke detectors, and gas alerts can be triggered by wireless carbon monoxide detectors. Wireless transmitters can also be confi gured as activity timer reset devices to verify activity at the subscriber’s location.

PERS-4200 Console

Page 5 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — Important PERS Installation Warnings
Page 5 · click to enlarge
Page 5
2. Operation Summary A variety of Linear’s DXS Format and DXT Format transmitters can be used with the Console.

Activity Switch or motion triggered transmitters (Models DXS-31/DXS-32 and DXS-54) can be used for ensuring human activity. The DXS-54 motion detector will monitor room activity. The DXS-31 and DXS-32 transmitters can be wired to a pushbutton or switch for manual activity monitoring. As long as a signal is received from each activity sensor during a programmed activity time window, an alarm will not be triggered. 15 minutes before the programmed time expires, the HOME indicator will start blinking and the Console will announce every three minutes that the timer will run out soon. The activity timer can be reset with a signal from one of the activity transmitters or by pressing the HOME button on the Console. Failure to reset the activity timer within the programmed time period will trigger the Console’s emergency alarm and send an inactivity report to the Central Station.

✓ NOTEDXS Format transmitters are supervised, DXT Format transmitters

are not supervised.

Transmitters can be assigned to the following four functions: Emergency Portable, pendant, belt-clip, or wristband type transmitters and stationary transmitters are used for personal emergency applications. When an emergency transmitter is triggered, the Console announces the emergency alarm and an emergency report is sent to the Central Station. The emergency alarm can also be triggered by pressing the Console’s HELP button. Fire The Model DXS-73 wireless photoelectric smoke alarm transmitter triggers the fi re alarm. When the fi re alarm is activated, the Console announces the fi re alarm and a fi re report is sent to the Central Station. Carbon Monoxide (CO) The Model DXS-80 wireless carbon monoxide detector triggers the CO alarm. When a carbon monoxide alarm is activated, the Console announces the gas alarm and a carbon monoxide report is sent to the Central Station.

2.1 Console Alarm Priorities Alarm Priorities by Type Each type of alarm is assigned a priority. Higher priority alarms override lower priority alarms. Smoke alarms (on/off horn sound) have the highest priority, followed by carbon monoxide alarms (on/off buzz sound), emergency alarms (3 beeps sound), then other types of maintenance and reminder reports (various sounds).

Linear Personal Emergency Reporting System (PERS-4200 Series) — Important PERS Installation Warnings diagram (page 5)
Fig. 3 · Important PERS Installation Warnings

UP TO 16 TRANSMITTERS TOTAL CAN BE USED WITH

PERS-4200 Compatible Transmitters

Page 6 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — Important PERS Installation Warnings
Page 6 · click to enlarge
Page 6

2.2 Console Options Cellular Interface Module The Model UMTS-3G Cellular Interface Module provides 2-way over-the-air digital communications between the Console and the monitoring service. The cellular module can be used to replace the traditional land-line telephone connection for emergency reporting. Remote Speaker/Microphone Module The Model RSM-MODULE Remote Speaker/Microphone Module extends the usable range for 2-way audio communications with the monitoring service. The plug-in module and its remote speaker/microphone unit allow the monitoring service to talk and listen to the subscriber from an additional location in the installation that is remote from the Console. Alternate Console Labels For customizing the Console, an alternate set of button identifi cation labels are provided. The labels describe the Console’s buttons in French, or Spanish language, or in Braille characters. Apply the label required to the Console, above the buttons. HOME Button Cover For installations where the activity timer will not be used, a snap-on button cover is supplied to hide the HOME button.

Linear Personal Emergency Reporting System (PERS-4200 Series) — Important PERS Installation Warnings diagram (page 6)
Fig. 4 · Important PERS Installation Warnings

PERS-4200 Plug-in Option Modules

Linear Personal Emergency Reporting System (PERS-4200 Series) — Important PERS Installation Warnings diagram (page 6)
Fig. 5 · Important PERS Installation Warnings

IF REQUIRED, APPLY BRAILLE, FRENCH, OR SPANISH LABEL TO CONSOLE

TO HIDE THE HOME BUTTON IF THE ACTIVITY TIMER IS NOT GOING TO BE USED, SNAP THE HOME BUTTON COVER INTO THE CONSOLE

✓ NOTEThe HOME button cover cannot be easily removed once the

cover is in place.

NOTCH IN THE BUTTON COVER LINES UP WITH NOTCH IN THE CONSOLE CASE

Alternate Console Labels and HOME Button Cover

Linear Personal Emergency Reporting System (PERS-4200 Series) — Important PERS Installation Warnings diagram (page 6)
Fig. 6 · Important PERS Installation Warnings

SPEAKER VOLUME MUST BE SET SO ANNOUNCEMENTS CAN BE HEARD FROM ACROSS THE ROOM

PERS-4200 Console Component Locations

Page 7 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — 3.3 Power Supply Installation 3.4 Local Programming Connection
Page 7 · click to enlarge
Page 7

3. Console Connections

3.1 Telephone Connections 3.2 Option Module Installation

Linear Personal Emergency Reporting System (PERS-4200 Series) — 3.1 Telephone Connections 3.2 Option Module Installation diagram (page 7)
Fig. 7 · 3.1 Telephone Connections 3.2 Option Module Installa…
Linear Personal Emergency Reporting System (PERS-4200 Series) — 3.1 Telephone Connections 3.2 Option Module Installation diagram (page 7)
Fig. 8 · 3.1 Telephone Connections 3.2 Option Module Installa…

THE TELEPHONE LINE WHILE THE CONSOLE IS REPORTING TO

3.3 Power Supply Installation 3.4 Local Programming Connection

Linear Personal Emergency Reporting System (PERS-4200 Series) — 3.3 Power Supply Installation 3.4 Local Programming Connection diagram (page 7)
Fig. 9 · 3.3 Power Supply Installation 3.4 Local Programming…
Linear Personal Emergency Reporting System (PERS-4200 Series) — 3.3 Power Supply Installation 3.4 Local Programming Connection diagram (page 7)
Fig. 10 · 3.3 Power Supply Installation 3.4 Local Programming…

INSERT MINI-USB PLUG INTO JACK ON REAR OF THE PERS-4200 CONSOLE

Page 8 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — 3. Console Connections
Page 8 · click to enlarge
Page 8
4. Console Modes & Features The Console operates in several modes and has features that support both the provider and the subscriber.

4.2 Provider Features Several features of the Console are designed to aid and support the system provider. Event Log The Console maintains a log of the 100 most recent system events. Each event is tagged with the date and time the event occurred. The log can be retrieved by the RA4200 software. Upgradable Firmware The PERS-4200 Console runs on internal software code called “fi rmware”. The PERS-4200 Console uses two fi rmware resources, system fi rmware and vocabulary fi rmware. Firmware code stays stored in the Console’s memory and can be upgraded using the RA4200 application when fi rmware updates become available. The Device Firmware Upgrade utility (DfuSe) (included in the RA4200 application) can upgrade a Console and the optional UMTS-3G cellular module. Multi-language Support The Console supports two resident languages. The default languages are English and Spanish. To use an alternate language, the vocabulary fi rmware fi le must be downloaded and installed in the Console’s memory with the RA4200 upgrade utility. Volume Controls Two volume controls are provided to customize the sound levels of the Console for the installation. Auto Supervision Any of the Console’s 16 sensor locations can be set to automatically detect status supervision signals from transmitters. This feature makes adding or replacing transmitters in fi eld units easier. Variable Supervision Time The Console can be set to delay reporting missing transmitter status supervision signals until 12 or 24 hours, or 3, 7, 14, or 30 days. (Smoke and CO detectors are always set at 24 hours per UL.) Transmitter Low Battery Double-Check The Console can be programmed to report a sensor low battery after the fi rst or second time a low battery signal is received from the sensor. Received Signal Strength (RSS) Test To assist in setup and troubleshooting, when a transmitter is activated while the Console is in Test Mode, the Console will measure and announce the received signal strength (RSS) of the transmitter. Remote Transmitter Enrolling To make fi eld transmitter replacement easy, the transmitter’s ID code can be remotely enrolled into the Console. The transmitter will be ready to operate with the Console without having to “learn” the transmitter in. Selectable Emergency Siren The emergency siren can be programmed for audible or silent to support different applications. (The smoke and CO siren are always active per UL.) Selectable Trouble Annunciation The annunciation for Console and sensor low battery or supervisory trouble can be audible or silent. (Trouble annunciation must be set to audible per UL). Selectable AC Power & Phone Line Fail Annunciation The annunciation for AC power failure and telephone line failure can be audible or silent. Audible annunciation can be set for only once, or once every hour.

4.1 Provider Modes The Console has special modes of operation to aid the installer during setup and confi guration. Power Off Mode Power Off Mode allows for out-of-service storage of the Console without discharging the backup battery. Not-Ready Mode For a Console to report, an account number, Central Station telephone number, and reporting format must be programmed. If these settings for PSTN reporting or IP reporting are incomplete, the Console will indicate Not-ready Mode. Programming Mode Programming Mode is used to setup and program the Console. It also can be used to retrieve the unit’s event log data. Test/Learn Mode Test/Learn Mode is accessible using a recessed button on the bottom of the Console. This mode can be used to locally learn, test, or erase multiple transmitters. While in Test/Learn Mode, all normal operations of the Console are suspended.

Linear Personal Emergency Reporting System (PERS-4200 Series) — 3. Console Connections diagram (page 8)
Fig. 11 · 3. Console Connections

General Wireless Installation Tips

Page 9 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — 3. Console Connections
Page 9 · click to enlarge
Page 9

4.3 User Modes The Console features three modes of operation for the user. Each mode changes the way the Console reacts or annunciates, depending on where the user is, or what time it is. Home Mode Home Mode is the standard mode of operation for the Console when the user is at home during the day. The Console will annunciate and report all alarms as programmed. The HOME button lights green when the Console is in Home Mode. Away Mode Away Mode is for when the user is going to be off site, away from the Console. Portable emergency transmitter status reports are not monitored while the Console is in Away Mode. Activity monitoring is suspended during Away Mode. Console supervisory faults are always reported, but not annunciated, in Away Mode. Pressing the HOME button for fi ve seconds with switch the Console between Home Mode and Away Mode. Night Mode Night Mode is an option that will suspend all Console supervisory annunciations during a selected time period. This mode allows the user to sleep without interruptions from the Console about most non-emergency conditions. Activity monitoring and reminder messages can be used during Night Mode, but are normally not scheduled during that time. Console supervisory faults are always reported, but not annunciated, in Night Mode. During the programmed time for Night Mode, pressing the HOME button for fi ve seconds with switch the Console between Night Mode and Away Mode. Emergency Reporting in any User Mode In any of the three user modes, the Console is ready to report an emergency. Emergency signals can be received from wireless sensors or can be triggered from the Console’s HELP button. The alarms are announced locally by type (emergency, fi re, or carbon monoxide alarm) through the Console’s speaker and are reported to Central Station. The Console will sound the alarm for fi ve minutes or until the report to the Central Station is complete (Console emergency siren is optional through programming). As the alarm is being reported, the Console will announce:

4.4 User Features Several features of the Console are designed to aid the system user. Activity Timer The activity timer is a feature that requires the subscriber to press a button or activate a transmitter during one or two preset time windows to prevent an inactivity alarm from being reported. The HOME indicator will blink during the activity timer window. When 15 minutes remain on the activity timer the Console will announce to the subscriber that the activity timer is running out. The subscriber must press the HOME button or trigger an activity transmitter to respond to the activity timer before it runs out, or an inactivity report will be sent. Switching the Console’s mode between Home or Night Mode and Away Mode will also reset the activity timer. Smoke & CO Detection For increased protection, wireless smoke and carbon monoxide detectors can be programmed into the Console and report these conditions to the Central Station. Smoke and CO sensors sound different Console announcements and send unique reporting codes. Reminder Messages Five pre-recorded reminder messages and an alarm sound can be programmed into the Console. The messages can be set to play once, daily, weekly, or monthly, at a set times and dates. The Console can also play a message to automatically remind the user to test the system. Temperature Alarms The Console contains a built-in sensor that constantly monitors the room temperature. The system can report and annunciate if the current room temperature measured is higher or lower than programmed temperature limits. A temperature restore report is sent when the room temperature returns between the high and low set points. As an option, temperature alerts can be programmed to be only active while the Console is in Home Mode. Speakerphone Mode The Console can be programmed to act as a hands-free speakerphone for incoming calls. If the user forgets to hang up, a timer will automatically disconnect the call. The speakerphone mode can only be used on incoming calls and will not function when the Console is operating from backup battery power. Attempting to answer while the Console is on backup power will cause an emergency alarm.

0 “Emergency call being placed”

✓ NOTEIf the Console communication is only through an IP connection

to the Central Station and it is not connected to a PSTN or MFVN telephone line, this feature will not function

If the connection to the Central Station is unsuccessful, the Console will repeat the announcement once during each 4-minute waiting period between call sets. Once the alarm is reported or all retry sequences have been exhausted, the Console will stop the annunciations and return indicators to normal. If 2-way audio is enabled, after the report is completed the Console will announce:

Remote User 2-Way Audio Using a 4-digit password, the Console can be called from any telephone and the caller can talk and listen to the user through the Console’s 2-way hands-free speakerphone either in voice-activated mode or manual switching mode.

✓ NOTEIf the Console was confi gured with the “Answer Phone” option

0 “Emergency reported... Please stand by”

NOT selected, this feature will not function.

✓ NOTEIf the Console communication is only through an IP connection

The Console will start the 2-way audio session (if enabled). If 2-way audio is not enabled, after the report is completed the Console will announce:

to the Central Station and it is not connected to a PSTN or MFVN telephone line, this feature will not function.

Console Status Alert The system continuously monitors the microprocessor that runs the Console’s fi rmware code. If the microprocessor ever stops executing the fi rmware code, the Console will indicate the trouble condition by sounding a steady tone from the speaker. The tone will continue until the condition is corrected.

0 “Emergency reported”

Page 10 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — 3. Console Connections
Page 10 · click to enlarge
Page 10
5. Using the Provider Modes The Console features special modes of operation to aid the installer during setup and confi guration.

5.1 Power Off Mode Power Off Mode allows for out-of-service storage of the Console without discharging the backup battery. The Console is shipped from the factory in this mode. To place the Console in Power Off Mode from any other mode, remove AC power, then press and hold the POWER OFF button on the bottom of the Console for three seconds. The next time AC power is applied, the Console will enter the programmed operating mode.

Linear Personal Emergency Reporting System (PERS-4200 Series) — 3. Console Connections diagram (page 10)
Fig. 12 · 3. Console Connections

PRESS THE POWER OFF BUTTON ON THE CONSOLE BOTTOM FOR 3 SECONDS

THE CONSOLE WILL ANNOUNCE POWER OFF AND THE INDICATORS WILL TURN OFF

5.2 Not-Ready Mode For a Console to report, an account number, Central Station telephone number, and reporting format must be programmed. If any of these settings are incomplete, the Console will indicate Not-ready Mode. If the Console assumes Not-ready Mode when AC power is applied, a 1-second beep will sound (and annunciate, if programmed) and the three indicators will blink green, orange, orange.

Linear Personal Emergency Reporting System (PERS-4200 Series) — 3. Console Connections diagram (page 10)
Fig. 13 · 3. Console Connections

IF THE CONSOLE DOES NOT HAVE AN ACCOUNT NUMBER, CENTRAL STATION TELEPHONE NUMBER (OR IP REPORTING ADDRESS), OR REPORTING FORMAT PROGRAMMED, THE CONSOLE WILL INDICATE THAT IT IS NOT READY

5.3 Programming Mode Programming Mode is used to setup and program the Console. It also can be used to retrieve the unit’s event log data. Programming Mode can be accessed with RA4200 software on a PC locally through a direct USB connection, remotely through a telephone connection, remotely through cellular connection (if the optional UMTS-3G cellular module in installed), or with limited access through a telephone connection using just a touch-tone telephone.

✓ NOTEDuring AC power loss, local and remote programming with

the RA4200 software is disabled unless the connection was already established at the time of power loss.

Linear Personal Emergency Reporting System (PERS-4200 Series) — 3. Console Connections diagram (page 10)
Fig. 14 · 3. Console Connections

When the Console is in Programming Mode, the three indicators will blink green, orange, red. Programming Mode will exit automatically after 3 minutes of inactivity, or by pressing the CANCEL button. While in Programming Mode, the Console is not operational and cannot receive or report alarms.

WHILE THE CONSOLE IS IN PROGRAMMING MODE, ALL THREE INDICATORS WILL BLINK

5.4 Test/Learn Mode Test/Learn Mode is accessible using the TEST button on the Console. This mode can be used to locally learn, test, or erase transmitters. To assist in setup and troubleshooting, when a transmitter is activated while the Console is in Test Mode, the Console will measure and announce the received signal strength (RSS) of the transmitter. Enter Test/Learn Mode by pressing the recessed TEST button on the bottom of the Console. Test/Learn Mode will exit automatically after 3 minutes of inactivity, or by pressing the CANCEL button. When the Console is in Test Mode, the HOME and CANCEL indicators will slowly blink green and orange. While in Test/Learn Mode, the Console is not operational and cannot receive or report alarms.

Linear Personal Emergency Reporting System (PERS-4200 Series) — 3. Console Connections diagram (page 10)
Fig. 15 · 3. Console Connections

THE CONSOLE WILL ANNOUNCE TEST MODE, THEN THE FIRMWARE AND HARDWARE VERSIONS

ACTIVATE ALL SYSTEM SENSORS, THE CONSOLE WILL ANNOUNCE SENSOR TYPE, ZONE, AND SIGNAL STRENGTH

✓ NOTETransmitters can also be learned one at a time using the CANCEL

button (see Section 12.2).

Show 4 more labels / short text on this page
Power Off Mode · Not-Ready Mode · Programming Mode · Test/Learn Mode
Page 11 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — 3. Console Connections
Page 11 · click to enlarge
Page 11
6. Programming with RA4200 Linear’s RA4200 software confi gures the PERS-4200 Console remotely or locally.

How does RA4200 connect to a Console? RA4200 can connect to the Console two ways:

  • Remote connection over the telephone line using the computer’s modem.
  • Local USB connection using a USB cable and the computer’s USB port. Once the connection is made, the Console will check if its remote access password matches the calling software’s password. If the passwords match, access is granted.

6.1 Software Description The RA4200 software described in this manual supports the programming Linear’s Model PERS-4200 Personal Emergency Reporting System. The software runs on an IBM PC or compatible computer.

Do I have to be connected to a Console to make programming changes? Since Remote Access knows the Console’s programming structure, you can modify an account template without being connected to a Console. This means you can set all of the values for a specifi c Console confi guration and then connect to a unit and send all of the values that you have set. This is referred to as off-line Console confi guration.

What is the RA4200 Remote Access Software? The RA4200 Remote Access software is communications software that programs all features of Linear PERS-4200 Consoles. It sets the options for: Console alarm, audio, and sensors; communicator telephone numbers, call routing, formats, reporting codes, account numbers, and reminder messages and more. The RA4200 can also display the Console’s event log. The RA4200 software has a help fi le that can be accessed at any time by selecting “Contents” from the “Help” menu or by pressing the F1 key. System Requirements

How do I change Console settings while on-line? While on-line with the Console, make any changes to the account template then send the data to change the Console.

Can I make a template with the typical settings for all of my accounts? Programming “templates” can be created to speed up programming multiple Consoles. Common settings, such as the Central Station telephone number, communicator format, Console and communicator confi gurations which are shared by all of your accounts can be stored in a generic account template. That template fi le can be used as a basis for creating multiple customer account template fi les.

  • IBM compatible personal computer with 2 GB RAM
  • Windows XP, Windows Vista, or Windows 7 operating system ✓ NOTE: Windows 64-bit operating systems may require “Windows XP

Mode” download from Microsoft for “Panel Firmware Update (Dfuse)” to run properly. See http://www.microsoft.com/windows/virtual-pc/ download.aspx

  • VGA monitor
  • For remote telephone connection, a ITU v.22bis standard 2400 baud Modem
  • For local connection, an available computer USB 2.0 port and a Type A to mini Type B USB cable.
  • An Internet connection
  • Hard disk drive with 50 MB available space for the software plus 18KB available space for each account template fi le
Linear Personal Emergency Reporting System (PERS-4200 Series) — 3. Console Connections diagram (page 11)
Fig. 16 · 3. Console Connections

RA4200 Programming Software

Page 12 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — 3. Console Connections
Page 12 · click to enlarge
Page 12
7. Programming Outline Use the following programming outline to guide you through the steps required to set up the RA4200 software and program a PERS-4200 Console. Many of the programming options available in the RA4200 program can be left in their default settings, and do not need to be changed for most installations.
8. RA4200 Software Installation The RA4200 remote access software is available on Linear’s web site at this link:

www.linearcorp.com/downloads.php The installation program will create a directory on your hard disk drive. Be sure that you have at least 50 megabytes free on the hard disk for the program and any account template fi les that you create.

  • Install the software on your computer (Section 7).
  • Test your computer’s modem (if used) (Section 8).
  • Start the RA4200 program (Section 9). Customize an Account Template

To Install the Remote Access Program: 1. Download the RA4200 programming software installation package from the Linear Web site at the link shown above. 2. Extract the RA4200Setup.ZIP fi le to expand the fi les. 3. Browse to fi nd the SETUP.EXE fi le. Double-click on SETUP.EXE and the installation program will start. 4. Click the Next button to install the Remote Access software. Follow the on-screen instructions as the setup program creates the directory and copies the program fi les onto your hard disk. The setup program will also install a virtual COM port driver to support a USB connection. If desired, select the check box to place a RA4200 Remote Access icon your desktop.

  • Open a new or existing account template (Section 10).
  • Enter customer information (Section 10.1).
  • Set the Console’s password and operational options (Section 10.2).
  • Enter any wireless sensor ID codes for sensors that won’t be learned locally (Section 10.3).
  • Select the Console’s communication method and options for PSTN and/or IP reporting (Section 10.4).
  • Choose the general communicator reporting options and assign any custom reporting codes (Section 10.5).
  • Set the Reminder Message schedules (Section 10.6). Program the Console with the Account Template
✓ NOTEIf RA4200 already is on your system and you are performing a

reinstallation, or an update, you will be prompted to modify, remove, or repair the RA4200 software.

  • Connect to the Console (Section 11.2).
  • Set the Console’s time and date (Section 11.3).
  • Send the account template data to the Console (Section 11.3). ✲ IMPORTANT! AFTER ANY PROGRAMMING CHANGES ARE MADE TO
✓ NOTEIF RA4200 IS INSTALLED ON WINDOWS VISTA OR WINDOWS 7,

RIGHT-CLICK ON THE DESKTOP ICON, SELECT PROPERTIES, SELECT THE COMPATIBILITY TAB, CHECK “RUN THIS PROGRAM IN COMPATIBILITY MODE”, AND SELECT WINDOWS XP.

A CONSOLE, PERFORM THOROUGH TESTING TO VERIFY THAT THE CONSOLE OPERATES AS INTENDED.

To Remove the Remote Access Program: 1. Press START, SETTINGS, CONTROL PANEL. Double-click on ADD/ REMOVE PROGRAMS. 2. Select Linear RA4200 and click ADD/REMOVE or CHANGE/ REMOVE button depending on your Windows Operating system.

✓ NOTEAlternately, you can select UNINSTALL from the Linear RA4200

folder on the start menu.

Setup RA4200 Software

Page 13 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — 3. Console Connections
Page 13 · click to enlarge
Page 13
9. Testing the Modem A modem is used when connecting to a Console remotely, over the telephone line. A modem is not required for local programming with a USB cable. When using a modem, be sure that the computer is running correctly and that the modem is installed and working properly before you run the RA4200 Remote Access Program. Use the following steps to test the modem and determine the computer’s COM port number that it is connected to.
Linear Personal Emergency Reporting System (PERS-4200 Series) — 3. Console Connections diagram (page 13)
Fig. 17 · 3. Console Connections

To Test the Modem in Windows XP Windows Control Panel can be used to test the modem and determine what COM port the modem is connected to. 1. Press START, SETTINGS, CONTROL PANEL. 2. Double-click on PHONE AND MODEM OPTIONS. 3. Click on the MODEMS tab. The modem and the COM port used should be shown. 4. Note the COM port number. It’s used when setting COM port in the RA4200 Send/Receive window (see Section 11.1). 5. Click PROPERTIES and select the DIAGNOSTICS tab. 6. Click QUERY MODEM. If the modem is connected and working properly, the Modem Information window will display detailed Command and Response modem information. If the modem is not working properly, Windows will notify you.

Windows XP Modem Test

Page 14 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — ACCOUNT TEMPLATE TABS
Page 14 · click to enlarge
Page 14
10. RA4200 Software Overview The RA4200 software is a Windows compatible program with menus and tabs to select various account fi elds to make selections and enter data.

Displays the 16 wireless sensor zones of the PERS-4200 Console. Each sensor zone displays its sensor ID number, sensor type, supervision option, two-way audio option, and the current sensor battery and supervision status.

10.1 Starting the Program To Run the Program: Double-click on the RA4200 desktop icon or press START, point to ALL PROGRAMS, Linear, RA4200 and click on RA4200. The RA4200 program will launch, displaying the menu bar and icons, the Account Template with its seven tabs, a communications status window, and a connection status indicator at the bottom.

Displays Console connection options for public switched telephone network (PSTN) and internet protocol (IP) reporting. Typical PSTN settings are for the communicator’s Central Station telephone numbers, account number, reporting format, audible dialing tones, and dialing format. Typical IP settings are for Central Station IP address and port numbers, IP account number, IP reporting format, voice gateway IP address and port numbers.

10.2 The Account Template Tabs Seven tabs are available for the Account Template. Each tab displays major areas for programming and administrating a PERS-4200 Console installation. The Account Template tabs function as follows:

Displays reporting options for the Console. Options for AC failure reporting, supervisory event reporting, mode switch reporting, automatic answer, automatic status report interval, speakerphone timer, two-way audio mode, dialing delay, and 4x2 reporting codes.

Displays fi ll-in fi elds for details of the subscriber’s information for the specifi c PERS-4200 installation. Fields include name, address, telephone numbers, customer ID#, and a large fi eld for special notes regarding the subscriber.

Displays the eight subscriber Reminder Message slots and their options. Also displays an option for setting the Reminder timeout interval and audio replay option. Each Reminder Message can be enabled, set for a type, and programmed to an activation schedule. An automatic system test reminder message can also be programmed.

Displays fi ll-in fi elds for setting information and options for the specifi c PERS-4200 Console. General settings such as passwords, siren enable, voice prompts, voice language, temperature limits, activity timer and Night Mode time windows can be set. Several other Console options and settings are also available in this tab. The Console’s time and date settings are displayed.

Displays the event log of the PERS-4200 Console. After the log is retrieved from the Console, this tab will show the system events with a time and date stamp in the order that they occurred.

Linear Personal Emergency Reporting System (PERS-4200 Series) — ACCOUNT TEMPLATE TABS diagram (page 14)
Fig. 18

ACCOUNT TEMPLATE TABS

CONNECTION STATUS

COMMUNICATIONS

INDICATOR

STATUS WINDOW

Show 8 more labels / short text on this page
Sensors · Communicator · Reporting Options · Customer · Reminder Messages · Console · Log · RA4200 Customer Tab
Page 19 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — SENSOR STATUS
Page 19 · click to enlarge
Page 19

11.3 Sensors Tab The Sensors tab displays fi ll-in fi elds for setting information regarding the wireless sensors programmed into the Console. Sensor status indicators also display the current condition of the sensor. Up to 16 wireless sensors can be used with each PERS-4200 Console. The transmitter’s ID number is printed on a removable tag attached to the unit’s lanyard.

Low Battery Report Options Supervised wireless sensors send low battery signals when they detect that their battery is low. When a low battery signal is received from a wireless sensor, two options are available to control when the Console reports a low sensor battery.

  • Option 1 - When a low battery signal is received from a sensor, the Console will immediately report a low battery.
  • Option 2 - When a low battery signal is received from a sensor, the Console will wait for another low battery signal from the same sensor within a 24 hour period before reporting a low battery. ✓ NOTE: In Night Mode, the low battery annunciations are suppressed, but
Linear Personal Emergency Reporting System (PERS-4200 Series) — SENSOR STATUS diagram (page 19)
Fig. 19

Console reporting is not.

Select Option 1 or Option 2 for the Console. This setting will affect all wireless sensors used with the Console.

Linear Personal Emergency Reporting System (PERS-4200 Series) — SENSOR STATUS diagram (page 19)
Fig. 20

SENSOR STATUS

Transmitter ID Tag · RA4200 Sensors Tab

Page 20 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — ID
Page 20 · click to enlarge
Page 20

Sensor Zones Each of the Console’s 16 wireless sensor zones has individual setup options. All the options are set on the Sensors tab.

Sensor Status Indicators On the Sensors tab, each of the Console’s 16 wireless sensors display the sensor’s operational status and if two-way audio is enabled for the sensor’s zone.

ID

Each wireless transmitter is coded with a unique ID number at the factory. If the transmitter has been locally “learned” by the Console, the ID number will appear in the ID fi eld. Alternately, transmitters can be enrolled remotely into the Console by entering the transmitter’s ID number into the ID fi eld. This feature is typically used when sending pre-enrolled replacement transmitters to the subscriber. When the subscriber receives the transmitter, it will be pre-programmed into the Console and ready for use.

A TWO-WAY AUDIO check box is provided to select if the sensor will start a two-way audio session after an alarm is triggered. Check this box to enable two-way audio for this sensor. If two-way audio has been globally disabled on the Reporting Options tab, the TWO-WAY AUDIO check box will be grayed out, but still show if it’s checked or not.

If a wireless sensor sends a low battery signal to the Console, when the Console’s data is read into the RA4200, the STATUS LOW BATT check box will be checked for that sensor’s zone.

Each sensor zone can be set to one of four sensor types, or set as Not Installed. When a wireless transmitter is locally “learned” by the Console, the sensor type will be automatically recognized and set by the Console. When a transmitter is enrolled remotely from the Console, the sensor type must be set manually. The sensor types selections available are:

If the Console fails to receive a status signal from a supervised wireless transmitter before the programmed time for TRANSMITTER SUPERVISION INTERVAL on the Console tab expires, the Console will indicate trouble and blink the CANCEL indicator. When the Console’s data is read into the RA4200, the STATUS TROUBLE check box will be checked for that sensor’s zone.

  • Not Installed - For sensor zones that are unused.
  • Fire - For smoke detector sensors.
  • Activity Reset - For sensors used to reset the Activity Timer.
  • Emergency - For sensors used to trigger the emergency alarm.
  • Carbon Monoxide - For CO detector sensors.

Supervised transmitters send recurring status signals to the Console. Any of the Console’s 16 sensor zone locations can be set to automatically detect status supervision signals from transmitters. This feature makes adding or replacing transmitters in fi eld units easier.

  • Select AUTO DETECT for a sensor zone to automatically detect if a wireless transmitter is sending status signals. Once the Console detects status signals from a transmitter, it will expect to regularly receive those signals or the Console will report that the transmitter is missing. The transmitter supervision interval required for the Console to report missing status transmissions is programmed in the Console tab.
  • Select DISABLE to set a sensor zone as a non-supervised zone which will not require status reports from a wireless transmitter.
Show 5 more labels / short text on this page
Two-way Audio Status · Low Battery Status · Type · Supervision Status · Supervised
Page 21 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — ID
Page 21 · click to enlarge
Page 21

11.4 Communicator Tab The Communicator tab displays fi ll-in fi elds for setting information regarding the Console’s communication method and options for PSTN and IP reporting. Communicator Fallback The Console’s communicator can report to the Central Station through the Public Switched Telephone Network (PSTN) or through Cellular IP reporting (if the UMTS-3G optional module installed).

PSTN Dialing Sequence The Console will make multiple attempts to make a connection with the Central Station. Each telephone number can be called up to 25 times. The communicator performs this dialing sequence to make a connection: 1. Call the primary telephone number to attempt to make a connection. If no handshake tone is detected from the Central Station, retry the primary telephone number up to fi ve consecutive times. 2. Call the secondary telephone number (if a secondary telephone number is used) to attempt to make a connection. If no handshake tone is detected from the Central Station, retry the secondary telephone number up to fi ve consecutive times. 3. Stop dialing and wait four minutes. 4. Repeat steps 1, 2, and 3 up to fi ve times. After all dialing attempts, if a connection to the Central Station is not made, the sequence repeats using the backup reporting path. When all retries are exhausted, the report buffer and Console indications are reset to normal; annunciations will cease and trouble memory and latched zones will return to normal. New events will cause a new attempt to contact the Central Station.

✓ NOTEThe PERS-4200 can report to a Central Station over phone

service provided by a Managed Facilities-based Voice Network (MFVN) carriers via the RJ11 phone jack, per NFPA 72 2010, section 3.3.141.

The communicator fallback option selects the reporting path the Console will use. Option boxes are grayed out for the reporting path that is not selected. The default is for dial-up PSTN reporting only. Select the option that is supported by the Central Station. Two options are available:

  • PSTN reporting only
  • Cellular IP reporting only When the communicator fallback option is selected, the 2-way audio setting will automatically adjust for the reporting method chosen (PSTN or IP reporting).
Linear Personal Emergency Reporting System (PERS-4200 Series) — ID diagram (page 21)
Fig. 21

RA4200 Communicator Tab

Page 22 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — ID
Page 22 · click to enlarge
Page 22

Public Switched Telephone Network (PSTN) Reporting Settings for dial-up reporting using the telephone network are set in this area.

Internet Protocol (IP) Reporting The PERS-4200 Console can be confi gured to communicate over-the-air (OTA) using the optional add-on Model UMTS-3G Cellular Module. The Module supports over-the-air data reporting for the PERS Console using 3G and voice communications through the carrier’s cellular telephone network. The settings for IP reporting using the cellular module are set in this area.

Account Number The account number can be up to 10 digits long. The last four digits of the account number will be used as the communicator’s account number for 4x2 and CID format reports to the monitoring service.

✲IMPORTANT! THE ACCOUNT NUMBER FIELD IS REQUIRED.

IP Account Number The FIBRO IP reporting protocol allows up to 10 digits in the account number. PERS truncates the left-most digits of the account number to fi t the reporting format used. The cellular module adds left-most zeroes as necessary for IP reporting. Enter the account number used for SurGard IP reporting for the specifi c Console.

  • SurGard System III - compatible SIA requires a 10-digit number
  • PSTN/SIA requires a 6-digit number
  • PSTN/CID and 4 by 2 requires a 4-digit number. Enter the account number for the specifi c Console.

Reporting Format Three Central Station PSTN reporting formats are available.

DNIS / Line # DNIS is used by the Central station to help identify accounts. This allows there to be multiple panels sending SIA/Contact ID events using account 1234 for example. The DNIS may be transmitted to the automation software/printer to ID account 1234 as belonging to dealer X (DNIS 00001) and the other account 1234 as belong to dealer Y (DNIS of 00002). If it is not used it should be sent as all 0’s and it will not allow the SIA/Contact ID account numbers to be extended.

  • Contact ID (CID)
  • SIA
  • 4 by 2 Contact ID is the default format. Select one of the other formats as required by the Central Station.

Dialing Format The default dialing format is DTMF tone dialing. If the telephone system that the Console will be connected to does not support DTMF tone dialing, select pulse dialing.

FIBRO Heartbeat Enter the time (in seconds) required by the Central Station receiver for the FIBRO heartbeat. Default is 7200 seconds.

Dialing Tones Audible By default dialing tones do not sound from the Console’s speaker. This option is typically used for troubleshooting telephone issues. Check this option box to have the Console speaker active during dialing.

Linear Voice Gateway Management Timer Enter the time (in minutes) for the periodic management connection to the voice gateway, used for over-the-air confi guration update and fi rmware download.

Primary Telephone Number The primary telephone number is the number that will be dialed fi rst in the dialing sequence. The number can be up to 20 digits including commas that each add a one second pause.

SIM ID Displays the Subscriber Identity Module ID being used in the cellular module.

Central Station IP Address The area is for entering the Central Station’s primary and secondary IP address’, local port, and remote port numbers for the server that will be receiving alarm reports from the Console. Enter the values required by the server.

✲IMPORTANT! THE PRIMARY TELEPHONE NUMBER FIELD IS REQUIRED.

Secondary Telephone Number The secondary telephone number is the number that will be dialed second in the dialing sequence if the primary number is unsuccessful. The number can be up to 20 digits including commas that each add a one second pause.

Voice Gateway The area is for entering the Central Station’s voice gateway IP address for the Linear Voice Gateway that will be handling voice-over-IP (VOIP) communications from the Console during 2-way audio mode. Refer to the Linear Voice Gateway instructions and settings for details.

Split Reporting The Console can report supervisory events to a supervisory telephone number if split reporting is enabled. Split reporting is disabled by default. When split reporting is enabled, reports for alarm events, reminder message timeouts, activity window expirations, and 2-way audio calls are made to the primary and secondary phone numbers. Reports of home/away mode, Console trouble conditions, sensor trouble conditions, and Automatic Status reports are made separately to the supervisory phone number only.

IP Reporting Format Three Central Station IP reporting formats are available.

  • Surgard System III-compatible SIA
  • Surgard System III-compatible CID18 Extended
  • Surgard System III-compatible CID58 Extended SURGARD SYSTEM III-COMPATIBLE CID18 EXTENDED is the default format. Select one of the other formats if required by the Central Station.

Supervisory Telephone Number The supervisory telephone number is the number that will be dialed to report supervisory events if split reporting is enabled. The number can be up to 20 digits including commas that each add a one second pause.

Cellular Network ID Used to connect to a specifi c network. This specifi es the numeric network identifi er, which is made from the Mobile Country Code (MCC) and Mobile Network Code (MNC).

IP Service The cellular service data network name string. For example: wap.cingular or m2m.com.attz.

LEMI Ports This area displays the name and fi rmware revision number of any option modules connected to the Console.

Page 23 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — — OR —
Page 23 · click to enlarge
Page 23

11.5 Reporting Options Tab The Reporting Options tab displays fi ll-in fi elds for setting information regarding the Consoles’ general communicator reporting options and includes a 4 x 2 section for assigning custom 4 x 2 reporting codes if desired. Report AC Fail The default REPORT AC FAIL setting enables AC power failure and restore reports with a random delay of up to one hour. Alternately, the Console can be set to report AC power status without the random delay, or be disabled. Three options are available for AC failure reporting.

Report Supervisory Events The default is to report supervisory events to the Central Station. The events will be reported to the primary/secondary telephone number unless split reporting is enabled, which would cause the reports to go to the supervisory telephone number. Un-check the REPORT SUPERVISORY EVENTS option box to disable reporting supervisory events. Mode Switch Reporting The Console can report to the Central Station when the Console is switched between Home Mode and Away Mode. The default MODE SWITCH REPORTING setting does not report mode changes to the Central Station. To report mode changes, check this option box. Answer Phone The default enables ring detection on the telephone line connected to the Console. This setting must be on to support the remote RA4200 telephone programming, remote limited touch-tone telephone programming, and Speakerphone Mode. If these features are not required or used, ring detection can be disabled by un-checking the ANSWER PHONE check box.

  • The DISABLE setting will inhibit AC failure reporting.
  • The ENABLE setting will report when the Console has been without AC power for fi ve minutes. A restore report will be sent fi ve minutes after AC power is restored.
  • The ENABLE (RANDOM DELAY UP TO 1 HOUR) settings functions the same as the ENABLE setting, except that any reports will occur at a random time up to one hour from the event. This option can reduce collisions of Central Station traffi c caused by a wide-spread power outage. When the AC power status changes, after the fi ve minute wait period, the Console will announce:

0 “Console power failure”

— OR —

0 “Console power restored”

Linear Personal Emergency Reporting System (PERS-4200 Series) — — OR — diagram (page 23)
Fig. 22

RA4200 Reporting Options Tab

Page 24 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — — AND —
Page 24 · click to enlarge
Page 24

Automatic Status Reports Automatic status reports of all pending supervisory conditions can be sent to the Central Station at a daily, weekly or monthly schedule until the supervisory condition is cleared or corrected. If split reporting is enabled, the automatic status report will be sent to the supervisory number only. The automatic status report consists of a periodic test report, followed operating mode report (Home Mode and Away Mode only) and any supervisory conditions. Supervisory conditions that are covered by the automatic status report include AC fail, Console low battery, missed sensor supervision, and sensor low battery for all sensors learned in to the Console.

Two-way Audio Mode The Console supports 2-way audio communications with the subscriber through the Console’s speaker and microphone. The default sets all Console sensors to have 2-way audio enabled. 2-way audio can be enabled or disabled for individual sensors using the check boxes on the Sensors tab. If 2-way audio activation is selected for an emergency sensor, after the monitoring service operator acknowledges the communicators report, the Console will stop its siren (if enabled) and switch to the selected audio mode for 90 seconds if:

  • Two-way audio mode is selected (listen-only, two-way manual, or two-way auto) in the RA4200 Reporting Options menu
✓ NOTESupervisory events are reported by automatic status report

regardless of the global REPORT SUPERVISORY EVENTS setting on the Reporting Options tab. Also, AC power loss events are reported by automatic status report regardless of the global REPORT AC FAIL setting on the Reporting Options tab.

— AND —

  • The zone where an alarm is being reported is enabled for two-way audio. Temperature Alarms have a separate setting to enable 2-way audio for those types of alarms. All other alarms or events are controlled solely by the global 2-way audio setting in the Reporting Options menu and will go into 2-way audio if that option is enabled. There are four choices for 2-way audio:

The default MODE setting for automatic status reports is disabled. To have the Console send automatic status reports, select one of the three MODE options:

  • Daily
  • Weekly
  • Monthly ✓ NOTE FOR UL APPLICATIONS: UL requires the Automatic Status Report
  • Disable (Globally) — Console will not report as an audio account to the Central Station. No audio monitoring will occur.
  • Two-Way Auto (default setting for PSTN reporting) — The Console automatically switches between listen and talk depending on which party is talking. The operator can still switch from listen to talk manually by pressing “1”, or switch from talk to listen by pressing “3” on a telephone connected to the line (with increased volume). Pressing “8” returns to two-way auto. Pressing “9” disconnects the call. Press any key but “9” to extend the time 90 seconds.
  • Two-Way Manual (default setting for IP reporting) — The operator will be able to hear sound from the Console and will be able to talk through the Console’s speaker. The operator can switch from listen to talk by pressing “1”, or switch from talk to listen by pressing “3” on a telephone connected to the line. Pressing “9” disconnects the call (press any key but “9” to extend the time 90 seconds).
  • Listen Only — The operator will be able to hear sound from the Console’s microphone, but will not be able to talk through the Console’s speaker. Pressing “9” on a telephone connected to the line disconnects the call (press any key but “9” to extend the time 90 seconds). Dialing Delay To help reduce false alarms reported to the Central Station, a delay of 15 seconds can be entered for PSTN or IP reporting. During this delay time, the subscriber can press the CANCEL button to cancel the alarm reporting to the Central Station. After the delay, once the call is initiated and the receiver handshake tone is detected (with PSTN reporting), or the IP packet is sent (with IP reporting), the report cannot be cancelled. The default setting for dialing delay is OFF. 4 x 2 Alarm Codes The 4 x 2 reporting format uses four digits for the account number and two digits for the alarm code. The Console defaults for 4 x 2 reporting assigns alarm codes 11-26 to Console zones 1-16, trouble codes 41-56 to Console zones 1-16, and 16 other general alarm codes. Any of the default 4 x 2 alarm codes can be modifi ed as necessary. Enter the new 2-digit code in the 4 x 2 area.

Mode option be set to DAILY.

For each option, set the time for the automatic test report to occur in the TIME area. The DAY area selects the day of week or day of month for the weekly and monthly automatic status reports. Extended Event Log The Console’s event log always records system alarm (Group 1) events. Additional events are categorized as Group 2 and Group 3 events. The default adds GROUP 2 and GROUP 3 events to the Console’s log:

  • Console mode changes (off, home, away, night)
  • Activity sensor activations
  • Inactivity alarm window expiration
  • Reminder message timeout expiration Group 3
  • Remote access (RA4200) sessions
  • Console supervisory events (AC power, low battery, phone trouble)
  • Sensor supervisory events (supervision, low battery)

Speaker Phone Timer The Console can be programmed to act as a hands-free speakerphone for incoming calls. If the user forgets to hang up, a timer will automatically disconnect the call. The default disables Speakerphone Mode. To use the speakerphone option, select 15, 30, or 60 minutes for the speakerphone automatic disconnect timer. Refer to the PERS-4200 User’s Guide for remote call-in speakerphone operation instructions.

Group 2

Page 25 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — — AND —
Page 25 · click to enlarge
Page 25

11.6 Reminder Messages Tab The PERS-4200 Console has a real-time clock calendar (RTCC) function that can be set to the correct time and date, and then accessed to schedule events and actions by the Console, including a scheduled reminder message feature. Five pre-recorded reminder messages are provided for this function and are included as part of each installed language library. There are nine programmable message time slots to use to set the reminder message types and schedule times.

Reminder Settings The reminder settings globally affect all nine programmable reminder message time slots.

Report Missed Reminder The Console will provide voice prompts during the 15 or 30 minutes prior to message reminder window expiring (set by programming). Upon expiration of message reminder window the following will occur if the REPORT MISSED REMINDER check box is checked. 1. The Console will activate and send an reminder message timeout report to the Central Station. If the missed reminder is a system test reminder, an automatic test report will be sent with status of the system. 2-way audio will not be initiated. 2. Upon receipt and processing of the alarm transmission, a 2-way audio session will begin (if enabled). To enable missed reminder message reporting, check the REPORT MISSED REMINDER check box.

✲IMPORTANT! THE CONSOLE’S TIME AND DATE MUST BE SET PRIOR

TO USING THE REMINDER MESSAGE FEATURE. All reminder messages (including alarm and system test reminder) are enabled only in Home Mode and Night Mode. They are disabled when in Away Mode. The PERS provider can schedule events for these reminder messages as a one-time reminder, or as a recurring daily, weekly, or monthly event. When the programmed event time is reached, the scheduled reminder message is announced and if enabled, repeats once every three minutes unless silenced by pressing the CANCEL button. When the CANCEL button is pressed to silence the announcement, the Console will sound a reminder chime. A 15 or 30-minute timeout interval can be programmed as a setting for all reminder messages. If the reminder is not acknowledged prior to expiration of the timeout interval, a missed reminder event report can be sent to the Central Station (if reporting of missed reminder messages is enabled). If multiple reminder messages are scheduled at the same time or in the same timeout interval, they will all be announced sequentially and at the same three minute intervals, based on the fi rst message annunciated. Pressing the CANCEL button cancels all of the reminder messages within the same timeout interval.

Audio Replay During Timeout The factory default will replay the reminder message every three minutes until the message is acknowledged or times out. To suppress replaying the reminder messages, un-check the AUDIO REPLAY DURING TIMEOUT check box.

Linear Personal Emergency Reporting System (PERS-4200 Series) — — AND — diagram (page 25)
Fig. 23

RA4200 Reminder Messages Tab

Page 26 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — — AND —
Page 26 · click to enlarge
Page 26

Timeout Interval A 15 or 30-minute timeout interval can be programmed as a setting for all reminder messages. If the reminder message is not acknowledged prior to expiration of the timeout interval, a missed reminder event report can be sent to the Central Station if reporting of missed reminder messages is enabled. The factory default sets the reminder message timeout to 15 minutes. Alternately, 30 minutes can be selected for the TIMEOUT INTERVAL. Reminder Time Slot Settings There are eight standard reminder message time slots that can be programmed and one time slot for the system test reminder. Each time slot has options that can be set.

Reminder Type Four types of reminder messages are available:

  • Medication reminder
  • Ride reminder
  • Appointment reminder
  • Alarm Select the desired type of reminder message for the time slot. When the selection is made, the Schedule Type dialog box will display.

Schedule Type Viewing or changing the reminder type or schedule type will display the Schedule Type dialog box. This area is for selecting the dates and times that a reminder message will sound. A reminder message can be scheduled for ONE TIME, DAILY, WEEKLY, or MONTHLY with the Schedule Type selection. Once a schedule is set, it will be displayed in the SCHEDULE area.

Slot Enable SLOT ENABLE check boxes are displayed for each of the nine reminder message time slots. Checking a SLOT ENABLE check box will enable the reminder message that is programmed in that time slot. A reminder message that’s already programmed can be temporarily disabled by un-checking this check box without loosing the reminder message settings.

Send Report SEND REPORT check boxes are displayed for each of the eight standard reminder message time slots. Checking a SEND REPORT check box for a reminder message time slot will cause the Console to report a non-acknowledged reminder message to the Central Station.

✓ NOTEFor any time slot to report, the global setting for missed reminder

reports must be enabled in the Reminder Settings area.

Linear Personal Emergency Reporting System (PERS-4200 Series) — — AND — diagram (page 26)
Fig. 24
Linear Personal Emergency Reporting System (PERS-4200 Series) — — AND — diagram (page 26)
Fig. 25
Linear Personal Emergency Reporting System (PERS-4200 Series) — — AND — diagram (page 26)
Fig. 26
Linear Personal Emergency Reporting System (PERS-4200 Series) — — AND — diagram (page 26)
Fig. 27
Show 9 more labels / short text on this page
One Time Reminder · Daily Reminder · Weekly Reminder · Monthly Reminder · Schedule · Schedule · Schedule · Schedule · RA4200 Schedule Types
Page 27 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — — AND —
Page 27 · click to enlarge
Page 27

Test Reminder A test reminder message is provided for prompting the subscriber to perform a system test. They will be prompted to activate their emergency transmitter or press the HELP button on the Console. Either activation will send a test report to the Central Station.

Creating or Editing Reminder Messages Use the following steps to setup a reminder message. Different options will be displayed depending on the type of message. 1. Choose a reminder message type. 2. Select One Time, Daily, Weekly, or Monthly for the Schedule Type. 3. Select the date(s) and time(s) that the reminder message will sound. 4. For ride or appointment messages, select the time for the ride or appointment to announce during the message. 5. Check the SLOT ENABLE check box to enable the reminder message time slot. The schedule displayed for the time slot will be grayed until it is enabled. 6. Check the SEND REPORT check box to have the Console send a report if this reminder message is not acknowledged. (Global missed reminder reports must be enabled also.)

✲ IMPORTANTIF USING THE TEST REMINDER MESSAGE FEATURE,

TWO-WAY AUDIO SHOULD BE ENABLED SO THAT THE CENTRAL STATION CAN ACKNOWLEDGE THE TEST WITH THE SUBSCRIBER.

When the programmed system test time occurs, a reminder chime sounds and the Console announces:

0 “Attention... It is time to test your personal emergency system... Please press your personal help button”

✓ NOTEThe test announcement will repeat every three minutes regardless

of the AUDIO REPLAY DURING TIMEOUT reminder message setting.

When the subscriber activates their emergency transmitter or presses the HELP button, the Console will send a test report to the Central Station, then start a two-way audio session. The Central Station operator typically acknowledges the test report with the subscriber using two-way audio, then disconnects. If the subscriber does not activate a transmitter or press the HELP button before the reminder timeout interval has been reached, an automatic test report will be sent to the Central Station.

✓ NOTEIf the system test reminder times out and an automatic status

report is sent, a two-way audio session will NOT be started, even if two-way audio is enabled.

Linear Personal Emergency Reporting System (PERS-4200 Series) — — AND — diagram (page 27)
Fig. 28

PERSONAL EMERGENCY SYSTEM PLEASE PRESS YOUR PERSONAL HELP BUTTON"

Acknowledging a System Test Reminder Message

Page 28 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — — AND —
Page 28 · click to enlarge
Page 28
12. Console Communication The RA4200 software connects to the PERS-4200 Console using the Send/Receive window. A Console must be connected to the RA4200 before any data can be sent to, or received from it.

12.2 Connecting to a Console Telephone Modem Remote Connection Use the following steps to remotely connect to a powered Console using a telephone modem: 1. Open the Account Template created for the specifi c subscriber and Console installation. The Console’s telephone number and password will be acquired from the template. 2. Press the CONNECT button to display the Send/Receive window. 3. Verify that the desired telephone modem is displayed for the connection. 4. Press CALL to start the calling sequence. The progress is displayed in the RA4200 connection status area. 5. The modem will place a call to the Console, wait a few rings, then hang up. This readies the Console to answer a call. The modem will call the Console again, the Console will answer and negotiate a connection with the modem. The RA4200 will send the password to the Console, if the passwords match, remote access will be granted. 6. When the connection is made, the green CONNECTED indicator will display at the bottom of the RA4200 window. 7. When fi nished, press DISCONNECT to disconnect with the Console. The red NOT CONNECTED indicator will display at the bottom of the RA4200 window.

12.1 Send/Receive Window The Send/Receive window sets up and starts a modem (remote) or COM port (local with USB) connection to a Console. Press the CONNECT button to display the Send/Receive window. Account The Account area has two settings. The telephone number fi eld and the password fi eld will be automatically fi lled in with the Console’s telephone number from the open account template. The telephone number and password fi elds can also be manually fi lled in. Modem Connection The area is used setting up and connecting with a computer modem over the telephone line. The SETUP CONNECTION button displays the general, diagnostic, and advanced Windows modem properties screens. The Query Modem button on the Diagnostics tab is a good way to test that the modem is working properly. The CALL button starts the modem calling sequence. COM Port Connection The COM Port Connection area has a selection for the COM port to use for the USB connection to the Console and a button to start the connection.

✓ NOTEIf the telephone line that the Console is connected to has

automatic telephone answering equipment that answers the line in three rings or less, the Console may not be able to be remotely accessed.

COM Port USB Local Connection During local USB programming, the Console will remain functional. Use the following steps to directly connect to a Console using a USB cable: 1. Apply power to the Console. 2. Connect the Console to the programming computer with a Type A to mini Type B USB cable. 3. Press the CONNECT button to display the Send/Receive window. 4. In the COM port Connection area, select the COM port that the Console is connected to. Look for the port labeled STMicroelectronics. 5. Press COM Port Connect to connect to the Console. The progress is displayed in the RA4200 connection status area. 6. When the connection is made, the green CONNECTED indicator will display at the bottom of the RA4200 window. 7. When fi nished, press DISCONNECT to disconnect with the Console. The red NOT CONNECTED indicator will display at the bottom of the RA4200 window.

Linear Personal Emergency Reporting System (PERS-4200 Series) — — AND — diagram (page 28)
Fig. 29
Linear Personal Emergency Reporting System (PERS-4200 Series) — — AND — diagram (page 28)
Fig. 30

INSERT MINI-USB PLUG INTO JACK ON REAR OF THE PERS-4200 CONSOLE

RA4200 Send/Receive Window · USB Programming Connection

Page 29 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — — OR —
Page 29 · click to enlarge
Page 29

12.3 Sending and Receiving Console Data Once the Console is connected to the RA4200 software, data can be exchanged in either direction. Console Time and Date The Console’s clock and calendar will maintain the current time & date.

Existing Console Programming Connecting to a Console with existing programming can be managed two ways:

  • Method 1: Make the changes to an Account Template off-line fi rst, before connecting to the Console, then connect to the Console and send it the template.
  • Method 2: Open an Account Template, connect to the Console, then retrieve the data from the Console into the template. The fi rst method is preferred when all programming for a Console has been made (and is being stored) by the RA4200 software. This method will keep all the PERS provider’s Consoles synchronized with the RA4200 Account Template fi les. The second method is useful if programming changes have been made to a Console through remote touch-tone telephone programming. Those changes can be retrieved into an Account Template, updating the template. Be sure to save the template after updating it. Use the following steps when programming an existing Console: 1. Open the Account Template created for the specifi c subscriber and Console installation. (When using Method 1, make any changes required.) 2. Connect to the Console. The green CONNECTED indicator will display at the bottom of the RA4200 window. 3. Method 1 - Press SET CONSOLE . The template will be sent to the Console.

✲IMPORTANT! THE CONSOLE’S TIME AND DATE MUST BE SET PRIOR TO

USE TO SUPPORT THE EVENT LOGGING AND REMINDER MESSAGE FEATURES.

✓ NOTEIf the Console is using IP reporting, the Console’s data and time

are automatically set by the cellular network.

If the Console’s clock or calendar needs setting or changing, use these steps. 1. Connect to the Console. The green CONNECTED indicator will display at the bottom of the RA4200 window. 2. Press CONSOLE TIME. The SetTime window will display. 3. To check a Console’s clock and calendar, press GET TIME. The current settings will be displayed in the SetTime window.

— OR —

4. Enter the new time and date. If daylight saving time is enabled, verify the start and stop dates. Press SET TIME to update the Console’s date and time. 5. Press DONE to close the SetTime window. First Time Programming for New Consoles When a Console is new or un-programmed it will announce:

— OR —

4. Method 2 - Press GET CONSOLE . The Console’s data will be sent to the template. Press SAVE and select an Account Template fi le name.

0 “Console not ready... please confi gure before use”

The Console must be programmed with an account number, a Central Station phone number and a corresponding PSTN or IP reporting format. If one or more of these required parameters is missing the Console will not operate. Use the following steps when programming a new Console: 1. Open the Account Template created for the specifi c subscriber and Console installation. 2. Connect to the Console. The green CONNECTED indicator will display at the bottom of the RA4200 window. 3. Press CONSOLE TIME. The SetTime window will display. If not correct, enter the correct time and date. If daylight saving time is enabled, verify the start and stop dates. Press SET TIME to update the Console’s date and time. Press DONE. 4. Press SET CONSOLE. The template will be sent to the Console. 5. Press DISCONNECT to disconnect from the Console. The red NOT CONNECTED indicator will display at the bottom of the RA4200 window.

✓ NOTEThe data in the open template will be overwritten with the data

from the Console.

5. Press DISCONNECT to disconnect from the Console. The red NOT CONNECTED indicator will display at the bottom of the RA4200 window.
Page 30 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — — AND —
Page 30 · click to enlarge
Page 30

12.4 Limited Remote Telephone Programming Some basic confi guration areas of the PERS-4200 Console can be programmed by a remote telephone phone call. The programming is limited to Reporting Format, Primary Phone Number, Account Number settings.

Option 2 - Primary Telephone Number When is pressed, the Console will announce over the telephone:

0 “Primary phone number is <primary phone number>... press pound to accept or press star to change”

✓ NOTEIf the telephone line that the Console is connected to has

Press the key to accept the current telephone number and return to the Remote Programming Main Menu, or press the key to enter a different telephone number. The primary telephone number can be up to 20 digits long, including delay characters. If more than 20 digits are entered, only the fi rst 20 digits will be accepted.

automatic telephone answering equipment that answers the line in three rings or less, the Console may not be able to be remotely accessed

In this remote programming mode, the Console remains fully functional and will continue to annunciate and report alarms as they occur, except for the few seconds when confi guration memory is being updated at the conclusion of a RA4200 programming session. Prior to the confi guration update, the Console will continue to use its previously stored settings for normal operation. If the remote programming connection is the same as the Console’s reporting connection, the Console will terminate the remote access session to report an alarm. This remote programming mode times out after four minutes of inactivity or by pressing the CANCEL button on the Console. Connecting with the Console Use the following procedure to connect with a Console with a touch-tone telephone: 1. Dial the number of the telephone line that the Console is connected to, allow it to ring three times, then hang up 2. Wait 10 to 30 seconds, then call the Console a second time. 3. When the Console answers, a tone will sound for 8 seconds. 4. When the tone ends, enter the PERS Provider Password (default 987654) followed by the key. 5. The Console will announce over the telephone:

✓ NOTETo place a delay at any location in the telephone number, press

the key. A 1-second delay will be inserted for each press of the key. When the primary phone number is annunciated for review, each 1-second delay will be identifi ed by the word “PAUSE.”

When is pressed, the Console will announce over the telephone:

0 “Enter primary phone number followed by pound”

Enter the new primary telephone number and press the key, the Console will announce:

0 “Primary phone number is <primary phone number>... press pound to accept or press star to change”

Press the key to accept the current change and return to the Remote Programming Main Menu. Option 3 - Account Number When is pressed, the Console will announce over the telephone:

0 “Account number is <account number>... press pound to accept or press star to change”

Press the key to accept the current account number and return to the Remote Programming Main Menu, or press the key to enter a different account number. The account number can be up to 10 digits long. PSTN/SIA requires a 6-digit number and PSTN/CID and 4x2 require a 4-digit number. The Console will left-truncate or left-pad the account number with zeros as required for the reporting format and interface.

0 “Press one to review or change report format”

0 “Press two to review or change primary phone number”

0 “Press three to review or change account number”

0 “Press nine to hang up”

6. Select the number of the programming option.
7. Press key at any time to return to main menu. Option 1 - Reporting Format When is pressed, the Console will announce over the telephone:

When is pressed, the Console will announce over the telephone:

0 “Enter account number followed by pound”

0 “Report format is <reporting format>... press pound to accept or press star to change”

Enter the new account number and press the key, the Console will announce:

0 “Account number is <account number>... press pound to accept or press star to change”

Press the key to accept the current format and return to the Remote Programming Main Menu, or press the key to return to select a different report format.

Press the key to accept the current change and return to the Remote Programming Main Menu. If more than 10 digits are entered, only the fi rst 10 digits will be accepted.

When is pressed, the Console will announce over the telephone:

0 “Press one for contact id”

✓NOTE: The default account number is none.

0 “Press two for SIA”

0 “Press three for four by two”

0 “Press nine to hang up”

0 “Press zero for main menu”

If selecting a new format, the Console will announce over the telephone:

0 “Report format is <reporting format>... press pound to accept or press star to change”

Press the key to accept the current format and return to the Remote Programming Main Menu.

✓NOTE: The default reporting format is Contact ID.

0 “Main menu”

Page 31 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — — AND —
Page 31 · click to enlarge
Page 31
13. Sensor Learn / Test Mode Wireless transmitters are called “sensors” in the PERS vocabulary. In Learn / Test Mode the Console can learn new sensors, test sensors, and erase all sensors.

13.1 Learning Sensors The Console can “learn” up to 16 sensors. Use the following steps to locally learn sensors into the Console: 1. Press and release the TEST button (located recessed on the bottom of the Console). The Console will announce:

✓ NOTEWhile in Learn / Test Mode, all normal operations of PERS-4200

Console are suspended. No alarms or reports are made in this mode.

0 “Test Mode, fi rmware version [number]... hardware version [number]”.

To exit this mode, press and release the CANCEL button. The Console will exit Learn / Test Mode automatically after three minutes of no activity (including RF activity from a learned sensor, which will extend Learn / Test Mode for an additional 3 minutes).

2. Press and release the TEST button again. The Console will announce:

0 “Ready to learn sensor... Zone [number]”.

3. Activate the sensor to learn. The Console will announce:

0 “[Fire, Activity, Emergency, or Carbon Monoxide] sensor learned”.

4. The Console will announce the next available zone number:

0 “Ready to learn sensor... Zone [number]”.

To advance to the next available zone without learning a sensor, press the TEST button. Zones already programmed with a sensor are skipped. 5. Repeat Step 3 for each additional sensor (up to 16 total). When all zone locations are full, the Console will announce:

After Zone 16 has been skipped or learned, if there are any available zones remaining, the learn sequence will advance to the fi rst available skipped zone and allow learning another sensor. The learn sequence will cycle through any available/skipped zones until either all zones are programmed, or Learn / Test Mode is exited.

✓NOTE: To exit Learn / Test Mode at any time, press the CANCEL button.

Linear Personal Emergency Reporting System (PERS-4200 Series) — — AND — diagram (page 31)
Fig. 31
3. CONSOLE WILL ANNOUNCE READY TO LEARN AND ZONE NUMBER
6. REPEAT FOR ADDITIONAL SENSORS, OR PRESS CANCEL TO EXIT

0 “Zones full” · Learning Multiple Sensors

Page 32 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — ✲ IMPORTANT! AFTER CONSOLE INSTALLATION, PORTABLE SENSORS
Page 32 · click to enlarge
Page 32

13.2 Learning a Single Sensor Learn Sensor Mode may also be entered by pressing and holding the CANCEL button for fi ve seconds. The Console will announce:

13.4 Testing Sensors Each sensor learned into the Console should be tested. When a sensor is tested, the Console will announce the type of sensor, the zone number, and the RF signal level.

0 “Ready to learn sensor... Zone [number]”.

✲ IMPORTANT! AFTER CONSOLE INSTALLATION, PORTABLE SENSORS

Activate the sensor to learn. The Console will announce:

SHOULD BE TESTED IN VARIOUS PLACES ON-LOCATION TO DETERMINE THE EFFECTIVE RADIO RANGE OF THE SYSTEM.

0 “[Fire, Activity, Emergency, or Carbon Monoxide] sensor learned”.

The Console will exit Learn Sensor Mode after learning one sensor. To exit without learning a sensor, press the CANCEL button.

Use the following steps to test each system sensor. 1. Press and release the TEST button (located recessed on the bottom of the Console). The Console will announce:

13.3 Erasing All Sensors To erase ALL sensors, press and hold TEST button for fi ve seconds. The Console will announce:

0 “Test Mode... fi rmware version [number]... hardware version [number]”.

2. Activate each sensor to test. For each sensor, the Console will announce:

All learned sensors are erased by this operation. The Console will then go to normal operation and announce:

0 “[Fire, Activity, Emergency, or Carbon Monoxide] sensor... zone [number]... [full or low] signal”.

If the sensor tested has a low battery, the Console will announce:

✓NOTE: Any pending alarms or events for an erased zone will be cleared.

0 “Sensor low battery... zone [number]”

3. When fi nished, press CANCEL to exit Test Mode (Test Mode will automatically exit after three minutes of inactivity).
Linear Personal Emergency Reporting System (PERS-4200 Series) — ✲ IMPORTANT! AFTER CONSOLE INSTALLATION, PORTABLE SENSORS diagram (page 32)
Fig. 32

0 “Zones reset” · 0 “Console ready” · Testing System Sensors

Page 33 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — ✲ IMPORTANT! AFTER CONSOLE INSTALLATION, PORTABLE SENSORS
Page 33 · click to enlarge
Page 33
14. Event Log The Console will log system events in its memory they occur. The log can be retrieved by the RA4200 software. Each event is tagged with the date and time that the event was recorded. The log contains the most recent 100 Console events. Three standard reporting groups are supported: Group 1 logging always occurs; all events related to alarms are logged:

14.1 Retrieving the Event Log Use the following steps to retrieve a Console’s event log: 1. Connect to the Console with the RA4200 application. 2. Press the GET LOG icon (also available under COMMUNICATIONS on the menu bar). 3. After the log is retrieved, it will be displayed on the LOG tab. Use the scroll bar to view the entire log. The most recent event is indicated in the log. 4. Disconnect from the Console.

  • Sensor alarms (emergency, fi re, CO)
  • Temperature alarms
  • HELP button alarms
  • 2-way voice sessions
  • Alarm reset/cancel
  • Central Station reports, attempts, retries and failures
  • All button presses Group 2 logging is optional; when enabled, mode changes, activity monitoring, and reminder message expiration events are logged:

14.2 Printing the Event Log The contents of the log can be printed with the account summary using the RA4200 PRINT / PREVIEW command.

14.3 Clearing the Event Log In case the Console is going to be moved, re-confi gured, or used in a different installation, the event log can be cleared from the Console’s memory. To clear the log: 1. Connect to the Console with the RA4200 application. 2. Select CLEAR EVENT LOG from the RA4200 TOOLS menu. 3. Disconnect from the Console.

  • Console mode changes (off, home, away, night)
  • Activity sensor activations
  • Inactivity alarm window expiration
  • Reminder message timeout expiration Group 3 logging is optional; when enabled, supervisory trouble and remote access events are logged:
  • Remote access (RA4200) sessions
  • Console supervisory events (AC power, low battery, phone trouble)
  • Sensor supervisory events (supervision, low battery) ✓ NOTE: Extended event logging options for Group 2 and Group 3 events

are selectable on the REPORTING OPTIONS tab.

Linear Personal Emergency Reporting System (PERS-4200 Series) — ✲ IMPORTANT! AFTER CONSOLE INSTALLATION, PORTABLE SENSORS diagram (page 33)
Fig. 33

RA4200 Console Event Log

Page 34 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — PRINT BUTTON
Page 34 · click to enlarge
Page 34

15. Printing or Exporting a Template For hardcopy records, an account template can be sent to a local printer connected to the PC running the RA4200 Remote Access software. The PRINT / PREVIEW tool also allows exporting an account template to an Excel .XLS fi le or an Adobe .PDF fi le. Use the following steps to print out or export an account template: 1. Open an account template in the RA4200 software. (Only one template can be open at a time.) 2. From the FILE menu select PRINT / PREVIEW or on the toolbar, click the PRINT icon. 3. The Account Information print preview window will be displayed. The preview shows the account template contents detailed on separate pages. The page that’s currently displayed and the zoom level can be selected using the page navigation icons in the window. 4. To print the account template,7 select the printer icon. The Windows print dialog box will appear, select any options, then click PRINT. 5. To export the account template, select the disc icon and choose Excel or Acrobat (PDF) fi le. Choose the fi le destination and click SAVE.

Linear Personal Emergency Reporting System (PERS-4200 Series) — PRINT BUTTON diagram (page 34)
Fig. 34

PRINT BUTTON

EXPORT BUTTON

Print Preview Window

Page 35 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — PRINT BUTTON
Page 35 · click to enlarge
Page 35

16. Updating Console Firmware The PERS-4200 Console runs on internal software code called “fi rmware”. Firmware code stays stored in the Console’s memory and can be upgraded using the RA4200 application when fi rmware updates become available. The PERS-4200 Console uses two fi rmware resources, system fi rmware and vocabulary fi rmware. The UMTS-3G cellular module also has device fi rmware. There is a Device Firmware Upgrade utility (DfuSe) included in the RA4200 application. When new fi rmware is released, it will be available on Linear’s Web site on the software download page at:

16.2 Firmware Update Utility Instructions Use these steps to upgrade a Console’s vocabulary fi rmware or the UMTS-3G cellular module’s fi rmware: 1. Download the fi rmware from Linear’s Web site and store the fi le(s) in a location on the programming PC. 2. Place the PERS-4200 in Power Off Mode by removing AC Power from the Console, and then press and hold the POWER OFF button until the Console announces: “Console power off”, then release the POWER OFF button. 3. Place the PERS-4200 into DfuSe mode by pressing and holding the POWER OFF button while applying AC Power. The HOME, CANCEL, and HELP indicators will blink.

www.linearcorp.com/downloads.php

✲ IMPORTANTOnce the Console is in DfuSe mode, do not power off the

16.1 System Firmware Update Utility Instructions Use these steps to upgrade a Console’s system fi rmware: 1. Download the system fi rmware from Linear’s Web site and store the fi le(s) in a location on the programming PC. 2. Place the PERS-4200 in Power Off Mode by removing AC Power from the Console, and then press and hold the POWER OFF button until the Console announces: “Console power off”, then release the POWER OFF button. 3. Place the PERS-4200 into DfuSe mode by pressing and holding the POWER OFF button while applying AC Power. The HOME, CANCEL, and HELP indicators will blink.

Console during a fi rmware upgrade.

4. Open the RA4200 application and BEFORE connecting the USB cable to the Console, from the RA4200 TOOLS menu, select Panel Firmware Update (DfuSe). 5. Connect the Console to the programming PC with a USB cable. If the Console is in DfuSe mode and properly connected to the USB port, the device ‘STM Device in FDU Mode’ should display in the “Available DFU and compatible HID Devices” area. 6. Click CHOOSE... and select the vocabulary fi rmware fi le or cellular module fi rmware fi le to download from the location it was saved on the PC. After selecting, “File correctly loaded.” should appear at the bottom of the DfuSe window. 7. Check the “Verify after download” check box. In the “Select

✲ IMPORTANTOnce the Console is in DfuSe mode, do not power off the

Console during a fi rmware upgrade.

4. Open the RA4200 application and BEFORE connecting the USB cable to the Console, from the RA4200 TOOLS menu, select Panel Firmware Update (DfuSe). 5. Connect the Console to the programming PC with a USB cable. If the Console is in DfuSe mode and properly connected to the USB port, the device ‘STM Device in FDU Mode’ should display in the “Available DFU and compatible HID Devices” area. 6. Click CHOOSE... and select the system fi rmware fi le to download from the location it was saved on the PC. After selecting, “File correctly loaded.” should appear at the bottom of the DfuSe window.

Target(s):” area select Target Id “02 SPI Flash” 8. When all settings are correct, click UPGRADE. 9. A DfuSeDemo pop-up dialog will always appear with a device warning. Ignore this warning and click YES. 10. The status bar will indicate the status of the upgrade. First phase will be erase, then download, then verify. 11. Click LEAVE DFU MODE. The RA4200 will disconnect the Console and the Console will reset. 12. Click QUIT to exit the DfuSe utility. 13. Confi gure the Console with the RA4200 as required.

7. In the “Select Target(s):” area select Target Id “00 Internal Flash” 8. When all settings are correct, click UPGRADE. 9. A DfuSeDemo pop-up dialog will always appear with a device warning. Ignore this warning and click YES. 10. The status bar will indicate the status of the upgrade. First phase will be erase, then download, then verify. 11. Click LEAVE DFU MODE. The RA4200 will disconnect the Console and the Console will reset. 12. Click QUIT to exit the DfuSe utility. 13. Confi gure the Console with the RA4200 as required.

✓NOTE: Should any problems happen during the upgrade phase (i.e.

wrong fi le selected and downloaded into a Console), this procedure can be repeated to retry the upgrade again.

✓NOTE: Should any problems happen during the upgrade phase (i.e.

wrong fi le selected and downloaded into a Console), this procedure can be repeated to retry the upgrade again.

Page 36 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — PRINT BUTTON
Page 36 · click to enlarge
Page 36
Linear Personal Emergency Reporting System (PERS-4200 Series) — PRINT BUTTON diagram (page 36)
Fig. 35
Linear Personal Emergency Reporting System (PERS-4200 Series) — PRINT BUTTON diagram (page 36)
Fig. 36

DfuSe Utility Connected to Console

Linear Personal Emergency Reporting System (PERS-4200 Series) — PRINT BUTTON diagram (page 36)
Fig. 37
Linear Personal Emergency Reporting System (PERS-4200 Series) — PRINT BUTTON diagram (page 36)
Fig. 38
Linear Personal Emergency Reporting System (PERS-4200 Series) — PRINT BUTTON diagram (page 36)
Fig. 39
Linear Personal Emergency Reporting System (PERS-4200 Series) — PRINT BUTTON diagram (page 36)
Fig. 40

Verify and Target ID Selection

Show 4 more labels / short text on this page
DfuSe Device Warning · Firmware File Selection · Upgrading in Process · Upgrade Complete
Page 37 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — REPORTING CODE
Page 37 · click to enlarge
Page 37

17. Appendix A - Reporting Codes

REPORTING CODE

EVENT DESCRIPTION

CID 4 X 2 SIA Group Partition (Ext)

CONSOLE EMERGENCY ALARM 1100 00 69 QA ALARM CANCEL (ABORT) 1406 00 70 AB CONSOLE LOW BATTERY 1302 00 73 YT CONSOLE BATTERY RESTORE 3302 00 71 YR CONSOLE SUPERVISORY (RECEIVER BOARD TROUBLE) 1381 00 40 MS CONSOLE SUPERVISORY RESTORE 3381 00 40 MJ LOSS OF AC POWER 1301 00 72 AT AC POWER RESTORE 3301 00 94 AR HOME MODE (ACTIVITY MONITOR ON) [1] 1372 00 91 UR AWAY MODE (ACTIVITY MONITOR OFF) [1] 1371 00 92 UB INACTIVITY ALARM (NO ACTIVITY) 1102 00 90 NA AUTOMATIC STATUS (AUTOMATIC TEST) 602 00 93 RP AUTOMATIC STATUS (TEST OFF NORMAL) 608 00 95 RY REMINDER MESSAGE TIME OUT [1] 1356 00 96 MI HIGH TEMP ALARM (HEAT) 1158 00 74 KA HIGH TEMP RESTORE 3158 00 75 KR LOW TEMP ALARM (FREEZE) 1159 00 76 ZA LOW TEMP RESTORE 3159 00 77 ZR FIRE (SMOKE) ALARM 1111 XX [2] 10 + SENSOR # FA FIRE (SMOKE) LOW BATTERY [1] 1384 XX [2] 40 + SENSOR # FT FIRE (SMOKE) SUPERVISORY 1200 XX [2] 40 + SENSOR # FS FIRE (SMOKE) SUPERVISORY RESTORE 3200 XX [2] 40 + SENSOR # FQ CO ALARM (GAS) 1162 XX [2] 10 + SENSOR # GA CO LOW BATTERY 1384 XX [2] 40 + SENSOR # GT CO SUPERVISORY 1381 XX [2] 40 + SENSOR # GS CO SUPERVISORY RESTORE 3200 XX [2] 40 + SENSOR # GQ EMERGENCY ALARM (PERSONAL/MEDICAL) 1101 XX [2] 10 + SENSOR # MA EMERGENCY LOW BATTERY 1384 XX [2] 40 + SENSOR # MT EMERGENCY SUPERVISORY 1381 XX [2] 40 + SENSOR # MS EMERGENCY SUPERVISORY RESTORE 3381 XX [2] 40 + SENSOR # MJ TWO WAY AUDIO REQUEST 606 00 N/A [3] L90

Reporting Code Notes:

  • 1 Optional report depending on programming.
  • 2 The CID Group/Partition # (Ext) code is the zone number that the alarm or event is reported against. Console and non-zone-specifi c alarms/events are reported using CID group/partition #00
  • 3 The 4x2 format does not have a two-way audio request code. The call must be established manually.
Page 38 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — N/A
Page 38 · click to enlarge
Page 38

18. Appendix B - Mode Table

CONSOLE OPERATING MODE

HOME MODE AWAY MODE (Overrides Night Mode) NIGHT MODE

Reports to Central Station

Reports to Central Station

Reports to Central Station

SYSTEM EVENT

Fire & CO Alarms ✓ Yes ✓ Yes ~ If Enabled [6] ✓ Yes ✓ Yes ~ If Enabled [6] ✓ Yes ✓ Yes ~ If Enabled [6]

Fire & CO Supervisory Timeout [2] ✓ Yes ~ If Enabled [8] N/A ✓ Yes ✗ No N/A ✓ Yes ✗ No N/A

Fire & CO Sensor Low Battery [2] ✓ Yes ~ If Enabled [8] N/A ✓ Yes ✗ No N/A ✓ Yes ✗ No N/A

Console (HELP button) Alarm ✓ Yes ✓ Yes ~ If Enabled ✓ Yes ✓ Yes ~ If Enabled ✓ Yes ✓ Yes ~ If Enabled

Emergency Sensor Alarm ✓ Yes ✓ Yes ~ If Enabled [6] ✓ Yes ✓ Yes ~ If Enabled [6] ✓ Yes ✓ Yes ~ If Enabled [6]

Emergency Sensor Supervisory Timeout [2] ~ If Enabled ~ If Enabled [8] N/A ✗ No [1] ✗ No [1] N/A ~ If Enabled ✗ No ✗ No

Emergency Sensor Low Battery [2] ✓ Yes ~ If Enabled [8] N/A ✓ Yes ✗ No [1] N/A ✓ Yes ✗ No N/A

Console Trouble [2] & [5] ✓ Yes ~ If Enabled

[8] & [9] N/A ✓ Yes ✗ No N/A ✓ Yes ✗ No N/A

Communication Status (telephone/cell) ✗ No ✓ Yes N/A ✗ No ✓ Yes N/A ✗ No ✗ No N/A

Module Status N/A ✓ Yes N/A N/A ✗ No N/A N/A ✗ No N/A

Activity Monitor ✓ Yes ✓ Yes ~ If Enabled [7] ✗ No ✗ No ✗ No ✓ Yes ✓ Yes ~ If Enabled [7]

Temperature Alarms ~ If Enabled [4] ~ If Enabled [4] ~ If Enabled [4] ~ If Enabled [3] ~ If Enabled [3] ~ If Enabled [3] ~ If Enabled [3] ~ If Enabled [3] ~ If Enabled [3]

Missed Reminder Messages ✓ Yes [11] ✓ Yes ~ If Enabled ✗ No ✗ No ✗ No ✓ Yes [11] ✓ Yes ~ If Enabled

Entering Mode ✓ Yes From Away Mode Only [10] N/A ✓ Yes ✓ Yes N/A From Away Mode Only

From Away Mode Only

N/A

Mode Table Notes:

  • [1] Setting the Console in Away Mode clears all supervisory events for emergency sensors only. Supervisory timers for Smoke detectors, CO detectors, and activity monitor sensors are not affected; switching to Home or Away Mode constitutes activity.
  • [2] Supervisory events are reported by automatic status reports regardless of the global REPORT SUPERVISORY EVENTS setting. Also, AC power loss events are reported by automatic status reports regardless of the global REPORT AC FAIL setting. Both settings are on the Reporting Options tab.
  • [3] If ENABLE HOME MODE ONLY is selected for TEMPERATURE LIMIT SETTINGS on the Console tab, temperature alarms will not occur in this mode. Select ENABLE to allow temperature alarms in this mode.
  • [4] Either ENABLE or ENABLE HOME MODE ONLY needs to be selected on the Console tab for TEMPERATURE LIMIT SETTINGS to allow temperature alarms.
  • [5] Console supervisory faults are always reported, but not annunciated in Away Mode and Night Mode.
  • [6] To start a two-way audio session after a report is triggered by an emergency alarm sensor, two-way audio must be globally enabled in TWO-WAY AUDIO MODE on the Reporting Options tab and enabled for the sensor’s zone with the TWO-WAY AUDIO check box on the Sensors tab.
  • [7] For activity sensors, two-way audio is enabled globally in TWO-WAY AUDIO MODE on the Reporting Options tab regardless of the activity sensor’s zone setting with the TWO-WAY AUDIO check box on the Sensors tab.
  • [8] To enable Console/sensor zone low battery and sensor zone supervision annunciations, ANNUNCIATE TROUBLE INDICATION must be selected on the Console tab.
  • [9] To announce telephone line and AC power status, ANNUNCIATE PHONE-LINE/AC STATUS must be selected on the Console tab.
  • [10] The Console will only announce Home Mode when manually switched from Away Mode using the HOME button.
  • [11] To report missed reminder messages, the global REPORT MISSED REMINDER option must be selected on the Reminder Messages tab and the reminder message slot must have the SEND REPORT option selected.
Show 6 more labels / short text on this page
Voice Announcement · Voice Announcement · Voice Announcement · Starts 2-Way Audio · Starts 2-Way Audio · Starts 2-Way Audio
Page 39 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — ‘OPEN’:
Page 39 · click to enlarge
Page 39

19. Appendix C - Communications Status Window Table

Below are possible messages that may appear in the communications status window when RA4200 is connected to a PERS-4200 Console.

‘GET CONSOLE’ (CELL MODULE PRESENT):

Tools->Clear Event Log:

Opening Port COM30 Initializing Com Port Sending password Login Success Get status data Console Type: Standard Console

Test IP reporting request sent

Initializing Com Port Sending password Login Success Get status data Console Type:

Tools-> File functions (when operation is cancelled):

Protocol Ver: 5 Hardware Ver: 0 Firmware Ver: 2.4.0 Data Version (zone-panel-reminder-log-time-IP- MiscConfi g1): -1-3-1-3-1-2-2 Console (PSTN) Account Number: 007152

SSH fi le transfer cancelled.

Tools -> Export fi le to Voice Gateway

SSH fi le transfer error.

or SSH export fi le transfer success.

Standard Console Protocol Ver: 5 Hardware Ver: 0 Firmware Ver: 2.4.0 Data Version (zone-panel-reminder-log-time-IP- MiscConfi g1): -1-3-1-3-1-2-2 Console (PSTN) Account Number: 007152

Console AC: Good Console Battery: Low Console Mode: Home Sensor Low Battery: Sensor Supervision Trouble: -1-2 Done Get Status Get time data Get zone data Get console data Get reminder data Get IP confi guration Cellular Signal Strength (dBm): -91 Get IP status data Cellular Status: --- Cellular Network: AT&T Cellular Roaming: --- Get status data Console Type: xxxxxx Console

Tools -> Retrieve Import fi le from Voice Gateway

SSH fi le transfer error.

or SSH import fi le transfer success.

Console AC: Good Console Battery: Good Console Mode: Home Sensor Low Battery: Sensor Supervision Trouble: Done Get Status

No merging error.

or Merging errors encountered.

‘CONNECT’ (no EXP. MODULES):

Opening Port COM30 Initializing Com Port Sending password Login Success Get status data Console Type: Standard Console

Protocol Ver: 5 Hardware Ver: 0 Firmware Ver: 2.4.0 Data Version (zone-panel-reminder-log-time-IP- MiscConfi g1): -1-3-1-3-1-2-2 Console (PSTN) Account Number: 007152

Protocol Ver: 5 Hardware Ver: 0 Firmware Ver: 2.4.0 Data Version (zone-panel-reminder-log-time-IP- MiscConfi g1): -1-3-1-3-1-2-2 Console (PSTN) Account Number: 007152

Console AC: Good Console Battery: Low Console Mode: Home Sensor Low Battery: Sensor Supervision Trouble: -1-2 Get Misc Confi g 1 Done Get Console

Console AC: Good Console Battery: Good Console Mode: Home Sensor Low Battery: Sensor Supervision Trouble: Done Get Status

‘GET CONSOLE’:

Get time data Get zone data Get console data Get reminder data Get IP confi guration Cellular Signal Strength (dBm): 0 Get IP status data Cellular Status: Cellular Network: Cellular Roaming: Get status data Console Type: Standard Console

‘SET CONSOLE’:

Set zone data Set console data Set IP Confi guration Set reminder data Set Misc Confi g 1 Done Set Console

‘GET LOG’:

‘SAVE’:

Saving C:\Linear\RA4200\Accounts\Account1.ra1

Protocol Ver: 5 Hardware Ver: 0 Firmware Ver: 2.4.0 Data Version (zone-panel-reminder-log-time-IP- MiscConfi g1): -1-3-1-3-1-2-2 Console (PSTN) Account Number: 007152

‘DISCONNECT’:

Terminate call Hanging up / Closing session Terminating... Please wait a few seconds. Wait Done.

Console AC: Good Console Battery: Good Console Mode: Home Sensor Low Battery: Sensor Supervision Trouble: Get Misc Confi g 1 Done Get Console

‘OPEN’:

Opening C:\Linear\RA4200\Accounts\Account1.ra1

Show 5 more labels / short text on this page
Done Clearing Log · Tools->Test IP Reporting · Opening Port COM30 · Tools->Merge Import · Get log data
Page 40 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — REGULATORY
Page 40 · click to enlarge
Page 40

20. Specifi cations

CODING FORMATS

DX CODE 24-BIT A1D PPM 1,048,567 Codes DXS CODE 24-BIT A1D PPM 1,048,567 Codes

POWER REQUIREMENTS

PRIMARY SUPPLY Plug-in Switching Power Supply Input: 120 VAC 60 Hz Output: 14 VDC 1.7 Amps Maximum BACKUP SUPPLY 7.2 Volt 2 Amp/Hour Ni-Mh Battery BACKUP OPERATION DURATION 24 Hours Minimum BATTERY LIFE EXPECTED 3 Years

RF CHARACTERISTICS

RECEIVER TYPE Dual-diversity Superheterodyne RF SENSITIVITY -105 dBm Typical RADIO FREQUENCY 315 Mhz MAXIMUM RANGE 1000 Feet Line-of-sight (Tested with DXS-LRC transmitter)

COMMUNICATOR

DIAL-UP COMMUNICATOR FORMATS 4 x 2, ADEMCO Contact ID SIA UL Tested with SURGARD SGMLRG-DG Central Station Receiver Central Station Receiver PSTN DIALING Tone or Pulse DIALING / IP REPORTING DELAY 0 or 15 Seconds IP REPORTING FORMATS Surgard System III-compatible SIA Surgard System III-compatible CID18 Extended Surgard System III-compatible CID58 Extended REMOTE PROGRAMMING PASSWORD 6 Digits REMOTE COMMUNICATIONS PASSWORD 4 Digits ACCOUNT NUMBER LENGTH SurGard FIBRO IP (SIA) 10-digits PSTN/SIA 6-digits PSTN/CID and 4 by 2 4-digits. PRIMARY TELEPHONE NUMBER 20 Digits SECONDARY TELEPHONE NUMBER 20 Digits SUPERVISORY TELEPHONE NUMBER 20 Digits CONSOLE STATUS REPORT Optional 1, 7 or 30 Day Report IP ADDRESSING IPv4 Addressing Only

CONSOLE

OPERATING TEMPERATURE 32°-120° F (0-49° C) ACTIVITY TIMER PERIOD Two Programmable Time Windows PSTN REPORTING AUDIO Listen-only, 2-way Manual, 2-way Voice Activated (duplex) Speakerphone IP REPORTING AUDIO Listen-only or 2-way Manual

SIZE 6.25” W x 2.85” H x 6.25” D (9.6” H with antenna up)

REGULATORY

CONSOLE Designed to conform to: UL 1635 Digital Alarm Communicator UL 1637, Home Healthcare Signaling Device Smoke Signaling Accessory File S2499 / UL217 National Fire Protection Association (NFPA 72) ROHS POWER SUPPLY CSA, ETL, FCC, Effi ciency Level 4 EMISSIONS FCC Part 15 & Part 68, Industry Canada

Page 41 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — 20. Specifi cations
Page 41 · click to enlarge
Page 41

21. Regulatory Information This device complies with Industry Canada and Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures.

  • 22. Linear Limited Warranty This Linear product is warranted against defects in material and workmanship for twelve (12) months. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until the warranty expires. This Linear LLC Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details. IMPORTANT WIRELESS INFORMATION Linear radio controls provide a reliable communications link and fi ll an important need in portable wireless signaling. However, there are some limitations which must be observed.
  • For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited range.
  • A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings.
  • Changes or modifi cations to the device may void FCC compliance.
  • Infrequently used radio links should be tested regularly to protect against undetected interference or fault.
  • A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users.
  • Reorient or relocate the receiving antenna
  • Increase the separation between the equipment and receiver
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
  • Consult the dealer or an experienced radio/TV technician for help Any changes or modifi cations not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
  • Les changements ou modifi cations non approuvés expressément par la partie responsable de la conformité pourrait annuler l’autorité de l’utilisateur à faire fonctionner l’équipement This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
  • Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. The antenna used for the transmitter must be installed to provide a separation distance of at least 7.87 inches (20 cm) from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter other than those supplied with the PERS-4200 console.
  • L’antenne de l’émetteur doit être installé à une distance d’au moins 7,87 pouces (20 cm) de toutes les personnes, et ne doit pas être placé ou utilisé en conjonction avec toute autre antenne ou tout autre émetteur autres que ceux fournis avec la console PERS-4200.
Page 42 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — 20. Specifi cations
Page 42 · click to enlarge
Page 42
Page 42 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — 20. Specifi cations
Page 43 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — 20. Specifi cations
Page 43 · click to enlarge
Page 43
Page 43 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — 20. Specifi cations
Page 44 of the Linear Personal Emergency Reporting System (PERS-4200 Series) user manual — 20. Specifi cations
Page 44 · click to enlarge
Page 44

Copyright © 2014 Linear LLC 237016 A

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Linear Personal Emergency Reporting System (PERS-4200 Series)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Linear Personal Emergency Reporting System (PERS-4200 Series)

Be the first to ask — other owners or our team will answer.

Original document

Linear Personal Emergency Reporting System (PERS-4200 Series) manual PDF

44 pages·1.6 MB·Medical Alarms·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…