NFPA 74 STANDARD FOR SMOKE DETECTOR LOCATION
STEP 7 Attach DF-72/EC to mounting plate. Match up alignment tabs on detector and plate. Turn detector clockwise until it locks in place. MATCH UP ALIGNMENT TABS TWIST DETECTOR CLOCKWISE TO LOCK TO MOUNTING PLATESTEP 8 Test smoke detector. Set the console into a test mode. Press and hold the smoke detector test button. Continue to hold the test button for at least 30 seconds after the noisemaker starts. Verify that the signal was received. CONTINUE TO HOLD THE SMOKE DETECTOR'S TEST BUTTON FOR ABOUT 30 SECONDS UNTIL THE CONSOLE'S SIREN STARTS PRESS AND HOLD DETECTOR TEST BUTTON, SMOKE DETECTOR'S BEEPER WILL START TO SOUND EMEREGCNY PLACE CONSOLE IN OFF MODE TO STOP SIREN, CHECK THAT THE SENSOR STATUS LIGHT IS BLINKINGNFPA 74 STANDARD FOR SMOKE DETECTOR LOCATION The DF-72/EC should be installed in accordance with National Fire Protection Association (NFPA) Standard 74, which reads as follows: 2-1.1.1Smoke detectors shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl spaces and unfi nished attics*. The provisions of 2-1.1.1 represent the minimum number of detectors required by this standard. It is recommended that the householder consider the use of additional smoke or heat detectors for increased protection for those areas separated by a door from areas protected by the required smoke detectors under 2-1.1.1 above. The recommended additional areas are: living room, dining room, bedroom(s), kitchen, attic (fi nished or unfi nished), furnace room, utility room, basement, integral or attached garage and hallways not covered under 21.1.1 above. However, the use of additional detectors remains the option of the householder. 2-1.1.2 For family living units with one or more split levels (i.e., adjacent levels with less than one full story separation between levels), a smoke detector required by 2-1.1.1 shall suffi ce for an adjacent lower level, including basements.
NFPA 74 STANDARD FOR SMOKE DETECTOR LOCATION Exception: Where there is an intervening door between one level and the adjacent lower level, a smoke detector shall be installed on the lower level. Ceiling mounted smoke alarms should be located in the center of the room or hall, or not less than 4 inches (10 cm) from any wall. When the detector is mounted on a wall, the top of the detector should be 4 to 12 inches (10-30 cm) from the ceiling. Do not install smoke alarms where normal ambient temperatures are above 100°F (37.8°C), or below 40°F (4°C). Also, do not locate alarm in front of air conditioners, heating registers, or other locations where normal air circulation will keep smoke from entering the detector. FIRE PREVENTION AND ESCAPE The purpose of an early warning smoke alarm is to detect the presence of fi re in its early stages, and sound an alarm giving the occupants more time to exit the premise before the smoke reaches a dangerous concentration level. Fires start even with the best of housekeeping and fi re prevention procedures. Fire is an unexpected event. Early warning detection alerts occupants in time to act. KNOW FIRE HAZARDS. No detection device can protect life in all situations. Therefore, safeguards should be taken to avoid such potentially dangerous situations as: smoking in bed, leaving children home alone, cleaning with fl ammable liquids such as gasoline.FIRE PREVENTION AND ESCAPE The best fi re protection is minimizing fi re hazards through proper storage of materials and general good housekeeping techniques. A cluttered basement, attic, or other storage area is an open invitation to fi re. Careless use of combustible materials and electrical appliances, or overloading of electrical outlets are other prime causes in starting fi res. It is most important that explosive and/or fast burning materials be eliminated from the home, if at all possible. Even after proper precautions have been taken, fi res can start. Be prepared. IN CASE OF FIRE. Leave immediately. Don’t stop to pack or search for valuables. In heavy smoke, hold your breath and stay low - crawl if necessary. The clearest air is usually at the fl oor. If you have to go through a closed door, carefully feel the door and door knob to see if undue heat is present. If they seem relatively cool, brace your foot against the bottom of the door with your hip against the door and one hand against the top edge. Open it slightly. If a rush of hot air is felt, slam the door quickly and latch it. Unvented fi re tends to build up considerable pressure. Be sure all the household realizes and understands this danger. Use your neighbor’s phone or a street fi re alarm box. The job of extinguishing the fi re should be left to the professionals. Too many unforeseen things can occur when inexperienced people try to extinguish a fi re.FIRE PREVENTION AND ESCAPE BE PREPARED. Perform fi re drills regularly. Use them to assure recognition of an alarm signal. For your protection, simulate different circumstances (smoke in hall, in living room, etc.). Then have everyone react to the situation. Draw a fl oor plan and show two exits from each room. Frequently a knotted rope or ladder from a window will serve this purpose. It is important that children be instructed carefully, because they tend to hide in times of crisis. It is imperative that one meeting place outside the home be established. You should insist that everyone meet there during an alarm. This will eliminate the tragedy of someone reentering the house for a missing member who is actually safe. If you have children and/or invalids residing in your household, you can help your fi re department. Most fi re departments have window decals available for use in children’s or invalid’s bedrooms. Properly used, these decals will quickly identify sleeping quarters of these individuals and show the fi re department where to look fi rst for members of your household. Additional information on Household Fire Warning is available at nominal cost from: The National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. Request Standard No. NFPA 74.
STEP 8 Test smoke detector. Set the console into a test
to extinguish a fi re.
at all possible.
BASEMENT
LIVING
ROOM
than one sleeping area, a smoke
STEP 7 Attach DF-72/EC to mounting plate. Match up
alignment tabs on detector and plate. Turn detector clockwise
ALIGNMENT
ExceptionWhere there is an intervening door between one level and the adjacent
Ceiling mounted smoke alarms should be located in the center of the room or hall,
or not less than 4 inches (10 cm) from any wall. When the detector is mounted on
a wall, the top of the detector should be 4 to 12 inches (10-30 cm) from the ceiling.
Do not install smoke alarms where normal ambient temperatures are above 100°F (37.8°C),
or below 40°F (4°C). Also, do not locate alarm in front of air conditioners, heating registers,
or other locations where normal air circulation will keep smoke from entering the detector.
The purpose of an early warning smoke alarm is to detect the presence of fi re in its early stages,
and sound an alarm giving the occupants more time to exit the premise before the smoke reaches
Fires start even with the best of housekeeping and fi re prevention procedures. Fire is an
KNOW FIRE HAZARDS. No detection device can protect life in all situations. Therefore,
safeguards should be taken to avoid such potentially dangerous situations as: smoking
in bed, leaving children home alone, cleaning with fl ammable liquids such as gasoline.
BEDROOM In family living units with more
MATCH UP
alarm should be provided to
and the rest of the family living unit. DINING KITCHEN BEDROOM TV
BEDROOM LIVING
TABS
NFPA 74 STANDARD FOR SMOKE DETECTOR LOCATION
protect each.
lower level, a smoke detector shall be installed on the lower level.
unexpected event. Early warning detection alerts occupants in time to act.
ROOM
FIRE PREVENTION AND ESCAPE
DETECTORS
SMOKE
DINING KITCHEN BEDROOM BEDROOM
ROOM
BEDROOM LIVING
located between the sleeping area
until it locks in place.
a dangerous concentration level.
A smoke alarm should be
LOCK TO MOUNTING
DETECTOR
TWIST DETECTOR
SMOKE
CLOCKWISE TO
PLATE
ROOM