Linear Smoke Detector (DF-72/EC)

2 pages·168 KB·Smoke detector·PDF·ENDEFRITNLJA
Linear Smoke Detector (DF-72/EC)
Table of Contents 38 sections NOTE: After replacing batteries, press transmitter test button to reset · DESCRIPTION · BOARD · BATTERY · … ShowHide
Page 1 of the Linear Smoke Detector (DF-72/EC) user manual — TWIST MOUNTING
Page 1 · click to enlarge
Page 1

NOTE: After replacing batteries, press transmitter test button to reset

Linear Smoke Detector (DF-72/EC) — NOTE: After replacing batteries, press transmitter test button to reset diagram (page 1)
Fig. 1 · NOTE: After replacing batteries, press transmitter t…
Linear Smoke Detector (DF-72/EC) — NOTE: After replacing batteries, press transmitter test button to reset diagram (page 1)
Fig. 2 · NOTE: After replacing batteries, press transmitter t…
DF-72/EC BY SMOKE DETECTOR For Use with DF-16/EC Security Console Installation Instructions (760) 438-7000 • FAX (760) 438-7043 www.linearcorp.comDESCRIPTION NOTE: After replacing batteries, press transmitter test button to reset The DF-72/EC is a high quality, photoelectric smoke detector with a “low battery circuit” built-in supervised digitally-coded radio transmitter. The DF-72/EC monitors and then transmits alarms, low battery, and test signals. The DF-72/EC sounds a local alarm as soon as smoke is detected. Twenty seconds after the local alarm sounds, the DF-72/EC’s transmitter will send an alarm signal to the console. The alarm signal will be repeated every 20 seconds as long as smoke is still present. Coding switches are not required or used in the DF-72/EC. Each transmitter is pre-coded at the factory to a unique code. With the DX format, there are more than one million codes possible. The smoke detector and transmitter are powered by two 9-volt batteries. These batteries are supplied with the transmitter and can power the unit for up to two years. If the battery voltage drops below a preset level, a low battery report is sent to the receiver every hour. STEP 1 Remove mounting plate. Remove the unit’s mounting plate by turning the plate counterclockwise. TWIST MOUNTING PLATE TO REMOVE UNLOCK MOUNTING PLATESTEP 2 Identify components. Examine the DF-72/EC to identify the component locations. TRANSMIT LED TRANSMITTER BOARD TRANSMITTER TEST BUTTON BATTERY COMPARTMENTSSTEP 3 Install batteries. Connect the two 9-volt batteries and place them into the battery compartments. CONNECT AND INSTALL TWO 9-VOLT ALKALINE BATTERIES

DESCRIPTION

BOARD

BATTERY

unit.

STEP 1 Remove mounting plate. Remove the unit’s mount-

STEP 4 Pick smoke detector location. Referring to the

tion to mount the DF-72/EC. Mounting the DF-72/EC on foil-

backed wallpaper or on a metal single-gang electrical box is

NFPA standard on the back of this sheet, select a good loca-

not recommended because the radio range will be reduced.

MOUNTING

UNLOCK REMOVE

DINING KITCHEN BEDROOM BEDROOM

PLATE

BEDROOM LIVING

BY

(760) 438-7000 • FAX (760) 438-7043

www.linearcorp.com

DETECTOR

SMOKE

DF-72/EC

For Use with DF-16/EC

DETECTOR

Instructions

TWIST MOUNTING

Installation

ROOM

SMOKE

PLATE TO

Security Console

Page 2 of the Linear Smoke Detector (DF-72/EC) user manual — LOCK TO MOUNTING
Page 2 · click to enlarge
Page 2

NFPA 74 STANDARD FOR SMOKE DETECTOR LOCATION

STEP 7 Attach DF-72/EC to mounting plate. Match up alignment tabs on detector and plate. Turn detector clockwise until it locks in place. MATCH UP ALIGNMENT TABS TWIST DETECTOR CLOCKWISE TO LOCK TO MOUNTING PLATESTEP 8 Test smoke detector. Set the console into a test mode. Press and hold the smoke detector test button. Continue to hold the test button for at least 30 seconds after the noisemaker starts. Verify that the signal was received. CONTINUE TO HOLD THE SMOKE DETECTOR'S TEST BUTTON FOR ABOUT 30 SECONDS UNTIL THE CONSOLE'S SIREN STARTS PRESS AND HOLD DETECTOR TEST BUTTON, SMOKE DETECTOR'S BEEPER WILL START TO SOUND EMEREGCNY PLACE CONSOLE IN OFF MODE TO STOP SIREN, CHECK THAT THE SENSOR STATUS LIGHT IS BLINKINGNFPA 74 STANDARD FOR SMOKE DETECTOR LOCATION The DF-72/EC should be installed in accordance with National Fire Protection Association (NFPA) Standard 74, which reads as follows: 2-1.1.1Smoke detectors shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit including basements and excluding crawl spaces and unfi nished attics*. The provisions of 2-1.1.1 represent the minimum number of detectors required by this standard. It is recommended that the householder consider the use of additional smoke or heat detectors for increased protection for those areas separated by a door from areas protected by the required smoke detectors under 2-1.1.1 above. The recommended additional areas are: living room, dining room, bedroom(s), kitchen, attic (fi nished or unfi nished), furnace room, utility room, basement, integral or attached garage and hallways not covered under 21.1.1 above. However, the use of additional detectors remains the option of the householder. 2-1.1.2 For family living units with one or more split levels (i.e., adjacent levels with less than one full story separation between levels), a smoke detector required by 2-1.1.1 shall suffi ce for an adjacent lower level, including basements. NFPA 74 STANDARD FOR SMOKE DETECTOR LOCATION Exception: Where there is an intervening door between one level and the adjacent lower level, a smoke detector shall be installed on the lower level. Ceiling mounted smoke alarms should be located in the center of the room or hall, or not less than 4 inches (10 cm) from any wall. When the detector is mounted on a wall, the top of the detector should be 4 to 12 inches (10-30 cm) from the ceiling. Do not install smoke alarms where normal ambient temperatures are above 100°F (37.8°C), or below 40°F (4°C). Also, do not locate alarm in front of air conditioners, heating registers, or other locations where normal air circulation will keep smoke from entering the detector. FIRE PREVENTION AND ESCAPE The purpose of an early warning smoke alarm is to detect the presence of fi re in its early stages, and sound an alarm giving the occupants more time to exit the premise before the smoke reaches a dangerous concentration level. Fires start even with the best of housekeeping and fi re prevention procedures. Fire is an unexpected event. Early warning detection alerts occupants in time to act. KNOW FIRE HAZARDS. No detection device can protect life in all situations. Therefore, safeguards should be taken to avoid such potentially dangerous situations as: smoking in bed, leaving children home alone, cleaning with fl ammable liquids such as gasoline.FIRE PREVENTION AND ESCAPE The best fi re protection is minimizing fi re hazards through proper storage of materials and general good housekeeping techniques. A cluttered basement, attic, or other storage area is an open invitation to fi re. Careless use of combustible materials and electrical appliances, or overloading of electrical outlets are other prime causes in starting fi res. It is most important that explosive and/or fast burning materials be eliminated from the home, if at all possible. Even after proper precautions have been taken, fi res can start. Be prepared. IN CASE OF FIRE. Leave immediately. Don’t stop to pack or search for valuables. In heavy smoke, hold your breath and stay low - crawl if necessary. The clearest air is usually at the fl oor. If you have to go through a closed door, carefully feel the door and door knob to see if undue heat is present. If they seem relatively cool, brace your foot against the bottom of the door with your hip against the door and one hand against the top edge. Open it slightly. If a rush of hot air is felt, slam the door quickly and latch it. Unvented fi re tends to build up considerable pressure. Be sure all the household realizes and understands this danger. Use your neighbor’s phone or a street fi re alarm box. The job of extinguishing the fi re should be left to the professionals. Too many unforeseen things can occur when inexperienced people try to extinguish a fi re.FIRE PREVENTION AND ESCAPE BE PREPARED. Perform fi re drills regularly. Use them to assure recognition of an alarm signal. For your protection, simulate different circumstances (smoke in hall, in living room, etc.). Then have everyone react to the situation. Draw a fl oor plan and show two exits from each room. Frequently a knotted rope or ladder from a window will serve this purpose. It is important that children be instructed carefully, because they tend to hide in times of crisis. It is imperative that one meeting place outside the home be established. You should insist that everyone meet there during an alarm. This will eliminate the tragedy of someone reentering the house for a missing member who is actually safe. If you have children and/or invalids residing in your household, you can help your fi re department. Most fi re departments have window decals available for use in children’s or invalid’s bedrooms. Properly used, these decals will quickly identify sleeping quarters of these individuals and show the fi re department where to look fi rst for members of your household. Additional information on Household Fire Warning is available at nominal cost from: The National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. Request Standard No. NFPA 74.

STEP 8 Test smoke detector. Set the console into a test

to extinguish a fi re.

at all possible.

BASEMENT

LIVING

ROOM

than one sleeping area, a smoke

STEP 7 Attach DF-72/EC to mounting plate. Match up

alignment tabs on detector and plate. Turn detector clockwise

ALIGNMENT

ExceptionWhere there is an intervening door between one level and the adjacent

Ceiling mounted smoke alarms should be located in the center of the room or hall,

or not less than 4 inches (10 cm) from any wall. When the detector is mounted on

a wall, the top of the detector should be 4 to 12 inches (10-30 cm) from the ceiling.

Do not install smoke alarms where normal ambient temperatures are above 100°F (37.8°C),

or below 40°F (4°C). Also, do not locate alarm in front of air conditioners, heating registers,

or other locations where normal air circulation will keep smoke from entering the detector.

The purpose of an early warning smoke alarm is to detect the presence of fi re in its early stages,

and sound an alarm giving the occupants more time to exit the premise before the smoke reaches

Fires start even with the best of housekeeping and fi re prevention procedures. Fire is an

KNOW FIRE HAZARDS. No detection device can protect life in all situations. Therefore,

safeguards should be taken to avoid such potentially dangerous situations as: smoking

in bed, leaving children home alone, cleaning with fl ammable liquids such as gasoline.

BEDROOM In family living units with more

MATCH UP

alarm should be provided to

and the rest of the family living unit. DINING KITCHEN BEDROOM TV

BEDROOM LIVING

TABS

NFPA 74 STANDARD FOR SMOKE DETECTOR LOCATION

protect each.

lower level, a smoke detector shall be installed on the lower level.

unexpected event. Early warning detection alerts occupants in time to act.

ROOM

FIRE PREVENTION AND ESCAPE

DETECTORS

SMOKE

DINING KITCHEN BEDROOM BEDROOM

ROOM

BEDROOM LIVING

located between the sleeping area

until it locks in place.

a dangerous concentration level.

A smoke alarm should be

LOCK TO MOUNTING

DETECTOR

TWIST DETECTOR

SMOKE

CLOCKWISE TO

PLATE

ROOM

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Linear Smoke Detector (DF-72/EC)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Linear Smoke Detector (DF-72/EC)

Be the first to ask — other owners or our team will answer.

Original document

Linear Smoke Detector (DF-72/EC) manual PDF

2 pages·168 KB·Smoke detector·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…