EN
Linear logo
Official user manual

Linear D-67L

1 pages·832 KB·TV Receiver·PDF·ENDEFRITNLJA
Linear D-67L
Page 1 of the Linear D-67L user manual
Page 1 · click to enlarge
Page 1
D-67 D-67L D-67F DX-12 D-67 STANDARD DIGITAL RECEIVERS Installation Instructions DX-12 USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - Toll Free FAX (800) 468-1340 www.linearcorp.com 1. PRODUCT DESCRIPTION Linear’s single-channel standard digital receivers are used in wireless security systems and for various remote control applications. The receiver is typically connected to inputs of a hardwired alarm control panel, providing wireless remote capability. Five models of the single-channel receiver are available. Model D-67: Standard receiver, the output triggers for a minimum of four seconds when activated and will stay triggered as long as the transmitter is activated. Model D-67L: Latching receiver, the output latches when activated until reset manually. Model D-67F: Toggling receiver, the output alternately latches and unlatches when activated. Model DX-12: Shielded receiver in a metal case with an external antenna input for connection to a Model EXA-1000 or EXA-2000 remote antenna, output triggers as long as the transmitter is activated. To set a security code, standard digital receivers contain an eight-position coding switch. The switch can be set to one of 256 possible unique codes. Standard digital transmitters also contain a coding switch. Each single-channel transmitter used with the receiver must be set to the exact same security code. The receiver will only activate from transmitters set with a matching code. Multi-channel standard digital transmitters require setting some of the receiver code switches to pre-defi ned settings to select the activation channel. Refer to the instructions included with multi-channel transmitters for coding requirements. For power, the D-67 & DX-12 receivers require 11-24 VDC or 12-16 VAC. The D-67L & D-67F receivers require 11-14 VDC or 12 VAC. Current consumption for all models is 15 mA during standby and 40 mA when the relay is energized. Each receiver’s relay output provides normally open and normally closed (Form “C”), with dry contacts (isolated from the power supply) rated at 1 Amp @ 32V AC/DC maximum, NEC Class 2 circuit. The operating temperature range of these receivers is -4° to +140° F (-20° to +60° C).2. COMPONENT LOCATIONS RR EE SL EA TY B L UA TT TC OH N COMM NO ON RMALLY OPEN TEOR RUE MTL IP NA U AY T LS COAN NT NE EN CN TOA R PO SW IW LE VIR R E E RIN S (P -)UT (MODEL D-67L ONLY) NORMALLY CLOSED GOLD (+) POWER INPUT WIRES SILVER (-) GOLD (+) RELAY OUTPUT FRONT D-67 FRONT TERMINALS NORMALLY CLOSED S ML OO UT NS T F INO GR ANTENNA DX-12 COMMON NORMALLY OPEN BRACKET CODING SWITCH CODING SWITCH BACK INSIDE 3. SETTING THE CODE SWITCH CHOOSE A CUSTOM SECURITY CODE FOR MULTI-CHANNEL TRANSMITTERS, DO NOT USE THE FACTORY SET CODE REFER TO THE INSTRUCTIONS SUPPLIED WITH THE TRANSMITTER USE A POINTED OBJECT TO SET ON/OFF FOR SPECIAL CODING REQUIREMENTS POSITIONS FOR KEYS 1-8 OF THE CODE SWITCH NOTE: AVOID SETTING SWITCHES ALL ON, ALL OFF, OR IN AN ALTERNATING ON/OFF OR OFF/ON PATTERN MATCH THE CODE IN ALL TRANSMITTERS USED WITH THE RECEIVER DON'T SET THE SWITCH WITH A PENCIL OR PEN, THE SWITCH MAY BECOME CONTAMINATED4. TYPICAL ALARM CONTROL PANEL CONNECTIONS RELAY OUTPUT NORMALLY CLOSED LOOP CONNECT THE RECEIVER RELAY OUTPUT ANTENNA T TRER IGM GIN ERAL ES D TO THE DEVICE TO BE GOLD + AUX OUTPUT RECEIVER COMMON NEGATIVE USE EITHER THE NORMALLY OPEN OR SILVER THE NORMALLY CLOSED TERMINAL AND COM N/C TYPICAL CONTROL PANEL THE COMMON TERMINAL ZONE 1 INPUT (N/C) IF REQUIRED, CONNECT AN END-OF-LINE COMMON LOOP RETURN RESISTOR AT THE RECEIVER AS SHOWN END-OF-LINE ZONE 2 INPUT RESISTOR RELAY RATING: IN SERIES 1 AMP @ 32V AC/DC MAXIMUM (IF REQUIRED) RECEIVER POWER NORMALLY OPEN LOOP CONNECT THE RECEIVER POWER INPUT ANTENNA WIRES TO THE POWER SOURCE CONNECT THE GOLD WIRE TO POSITIVE GOLD + AUX OUTPUT A (IGN ND O T RH EE PS OIL LV AE RR IT W YI R IFE C T OO N N NE EG CA TIT NIV GE T O RECEIVER SILVER COMMON NEGATIVE AN AC POWER SOURCE) COM N/O TYPICAL CONTROL PANEL POWER REQUIREMENTS: ZONE 1 INPUT (N/O) D-67 & DX-12: 11-24 VDC OR 12-16 VAC COMMON LOOP RETURN D-67L & D-67F: 11-14 VDC OR 12 VAC END-OF-LINE ZONE 2 INPUT ALL D-67s & DX-12: 15 mA STANDBY, 40 mA RELAY ON RESISTOR IN PARALLEL (IF REQUIRED)5. ANTENNA CONNECTION (FOR MODEL DX-12 ONLY) SCREW THE ANTENNA'S CABLE INTO THE ANTENNAS RECEIVER'S ANTENNA CONNECTOR AVAILABLE FOR THE DX-12: NOTE: THE ANTENNA CABLE MAY BE EXTENDED UP TO 20 FEET, USE TYPE RG-59 MODEL EXA-2000 CO-AX AND TYPE "F" CONNECTORS DIRECTIONAL ANTENNA NOTE: SIGNAL LOSS FROM EXTENDING THE ANTENNA CABLE MAY REDUCE THE RADIO RANGE MODEL LA-P 9" WHIP LOCAL ANTENNA (CONNECTS DIRECTLY TO THE RECEIVER) MODEL EXA-1000 OMNI-DIRECTIONAL ANTENNA 6. MOUNT RECEIVER FOR D-67 RECEIVERS FOR DX-12 RECEIVERS ATTACH THE SUPPLIED MOUNTING BRACKET TO THE MOUNTING SURFACE NOTE: FOR BEST RADIO RANGE, MOUNT THE RECEIVER AS HIGH AS POSSIBLE, AWAY FROM OTHER RECEIVERS AND POSSIBLE INTERFERENCE SOURCES IMPORTANT: DO NOT MOUNT D-67 RECEIVERS INSIDE A METAL ENCLOSURE USE APPROPRIATE CLIP RECEIVER FASTENERS TO SECURE ONTO MOUNTING THE RECEIVER TO BRACKET THE MOUNTING SURFACE NOTE: DX-12 RECEIVERS MAY BE MOUNTED INSIDE A METAL ENCLOSURE AS LONG AS THE REMOTE ANTENNA IS LOCATED OUTSIDE OF THE ENCLOSURE STRAIGHTEN OUT ANTENNA WIRE7. TEST SYSTEM 1. APPLY POWER TO THE RECEIVER. BE SURE THE ALARM CONTROL PANEL IS DISARMED OR IN A TEST MODE. 2. TRIGGER EACH TRANSMITTER CODED TO THE RECEIVER. THE RECEIVER RELAY SHOULD CLICK. VERIFY THAT THE PROPER ALARM CONTROL PANEL LOOP IS VIOLATED WHEN THE RECEIVER ACTIVATES. IF THE RECEIVER FAILS TO ACTIVATE, CHECK THE CODE SWITCH SETTINGS AND VERIFY THAT RECEIVER HAS POWER. 3. WITH PORTABLE TRANSMITTERS, OPERATE THEM FROM VARIOUS LOCATIONS TO DETERMINE THE USABLE RADIO RANGE OF THE SYSTEM. THIS WILL HELP TO LOCATE POSSIBLE TROUBLE AREAS WHERE METAL OR OTHER MATERIALS MAY SHIELD THE RECEIVER FROM THE TRANSMITTER. IMPORTANT: ELECTRONIC PRODUCTS ARE NO BETTER THAN THE INSPECTION AND MAINTENANCE THEY RECEIVE OVER TIME. THEREFORE, INSTALLERS SHOULD INSTRUCT THEIR CUSTOMERS TO TEST THIS EQUIPMENT REGULARY, AT LEAST ONCE A WEEK.LINEAR LIMITED WARRANTY This Linear product is warranted against defects in material and workmanship for twelve (12) months. This warranty extends only to wholesale customers who buy direct from Linear or through Linear's normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer's warranty, if any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until the warranty expires. This Linear LLC Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details. IMPORTANT !!! Linear radio controls provide a reliable communications link and fi ll an important need in portable wireless signaling. However, there are some limitations which must be observed. ✶ For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited range. ✶ A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings. ✶ Changes or modifi cations to the device may void FCC compliance. ✶ Infrequently used radio links should be tested regularly to protect against undetected interference or fault. ✶ A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users. Copyright © 2008 Linear LLC 218071 B

Ask about the Linear D-67L

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Linear D-67L

Be the first to ask — other owners or our team will answer.

Original document

Linear D-67L manual PDF

1 pages·832 KB·TV Receiver·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…