EN
Linear logo
Official user manual

Linear AP-1

2 pages·179 KB·Video Game Controller·PDF·ENDEFRITNLJA
Linear AP-1
Table of Contents 29 sections (619) 438-7000 • FAX (619) 438-7043 · TRANSMITTER · ACCESS GRANTED · SUSPENDED · … ShowHide
Page 1 of the Linear AP-1 user manual — AP-1
Page 1 · click to enlarge
Page 1
® AP-1 W Coir ne tl re os s A ec cc ee ivs es ONCNE NCN1VA PA2 O O C O C OR CEM M2 N/T4 H VRD EG C OQN A BRUD RP C SI EE ENO C TLS LPW E AA ATU S CYE YT S LR E TR SA OA RN UC C ANU C S C DSM E P U IM S OE PB S NI IE T EDGR DT R EE DAR NTED POWER l R r Installation Instructions (619) 438-7000 • FAX (619) 438-7043 USA & Canada (800) 421-1587 & (800) 392-0123 Toll Free FAX (800) 468-1340The AP-1 is designed for a broad range of access control applications. Its wireless programming locations, the total number of transmitters programmed, first available design, small size and dual relay outputs make it easily adaptable for a variety of access programming location and firmware version number. control requirements. Typically, the AP-1 is used to control a door strike, barrier gate, automatic gate or automatic door operator. The AP-1 can fully supervise the MGT safety edge transmitter. The system monitors the MGT transmitter for hourly status reports, tamper signals and low battery signals. The AP-1 contains a high-gain UHF receiver which uses an external antenna to pick A beep will sound every 5 seconds if a fault occurs and the trouble source can be up signals from up to 250 feet away. Up to 169 Linear MegaCode Format transmitters displayed by pressing pound (#)-1. For a trouble indication, a transmitter must be and one Model MGT safety edge transmitter can easily be programmed into the AP-1’s activated twice to trigger the ACCESS RELAY if a supervisory condition exists on the memory. The AP-1 will retain its memory, even without power. MGT transmitter. Two dry contact relay outputs are standard. One relay is the ACCESS RELAY, which triggers for two seconds each time a programmed transmitter is activated. This relay output connects to the pushbutton or radio input of the access device. The second relay MOUNTING SCREWS is the OBSTACLE RELAY, which triggers for two seconds when an obstacle signal is sent from a Model MGT safety edge transmitter. This relay output connects to the o h T swb a hs r e id tt a w A hc Pi l r ue e -1 i an c tcp oatu i nv 1t a o bt Af i eo mt h n pe oo wa f c t e ahc r ce ee ds .a s c f rd c o nee m sv Es ic A1 e d 2 R. e - T2A v H4in c e VO owP RltiE st Oh N A a CR Nn E DoeQ rx t eDU e rCrE mnS .a nTT l ahp i len u ip s sFu h o pt b r rt u m oe t vr t om iC dni en . r dea ll a i ys s o au u np t pp oul pi te ts id c nf ao anr NCNO NCNE 1VA PA O2 O C O C OR ECM2 M.T ..N/ .4H VRD G EC ON Q A BD RU RP C SIE E EON C TLS LWP E AA ATU S CE Y YT S LR E TR SA OA RN UC CN AU C S C DSM E P U IM S OEB PS NI IET EG DRT DR EE A DR NTED POWER W ANH TIP ENNA F N LOU8 CT1 K C A WNO ADN SN HE EC RTOR c p p e h A G U t i a s o l 3-FOOT connection for maximum lightning and static protection. ACCESSPRO MODEL AP-1 RECEIVER A CN AT BE LENNA TRANSFORMER AP-1 FEATURES NUMERIC KEYPAD SUSPEND BUTTON LEARN BUTTON DIGITAL DISPLAY For entering memory Prevents selected transmitter from Push after entering POWER INDICATOR TERMINAL STRIP Displays transmitter numbers location numbers and activating the access relay but transmitter number to start For connection of earth ground, during operation and utility function numbers. does not remove it from memory. learn cycle. To complete the Lights when AC or DC power and open request inputs programming. Also displays cycle, activate a transmitter power is applied to the ANTENNA CONNECTOR plus access and obstacle relay MGT supervision status and while occupied light is unit. For direct connection to outputs. system utility information. blinking. the local whip antenna or, with coax cable, to ACCESS GRANTED INDICATOR the remote antenna. Lights when the access DELETE BUTTON or obstacle relay is SUSPENDED INDICATOR Push once after entering the energized. Lights when a signal is transmitter number to delete. OCCUPIED INDICATOR received from a Press again while the occupied transmitter that has Lights when the POUND (#) KEY light is blinking to delete been suspended from displayed memory Adds 1 to the displayed number. Also selected transmitter from use. location is occupied. press # then 1-5 for utility functions: memory. Blinks during transmitter RADIO INDICATOR l te raa nrn sm cy itc tele r ia sn dd e b lee tf eo dr .e Lights when a radio DisplaysS tT hAR e ( n*) u K mEY ber of the last Push O toPE N a cBU tiT vT aON te the access # #- -1 2 D Di is sp pl la ay ys s M nuG mT b s eu r p oe f r ev mis po tr yy mst ea mtu os. ry locations. signal is detected on the transmitter activated or relay. Also clears any #-3 Displays number of occupied memory locations. frequency to which the subtracts 1 from the displayed supervisory trouble codes from #-4 Displays first available memory location. receiver is tuned. number. MGT transmitter. #-5 Displays firmware version number. RECEIVER INSTALLATIONANTENNA INSTALLATIONELECTRICAL CONNECTIONS MOUNT RECEIVER USING THE FOUR SCREWS PROVIDED 1. Mount receiver in an area protected from the elements. 2. If using the local whip antenna, the higher the receiver is mounted, the better the radio range will be. 3. Optionally, mount the receiver in a metal cabinet and use an external antenna.LOCAL ANTENNA REMOTE ANTENNA EXA-1000 REMOTE ANTENNA Attach local whip Mount F-81 connector Use the optional antenna directly to on surface using EXA-1000 antenna receiver. Bend whip to lockwasher and nut. mounted as high as point antenna up. Connect to receiver possible for best radio with coax cable and range. Connect to screw whip antenna to receiver with RG-59 connector. coax cable. ATTACH F-81 WHIP CONNECTOR ANTENNA COAX TO RECEIVER EXA-1000 ANTENNAEARTH GROUND Ground stake, cold water pipe or unified earth ground. 12-24 VOLTS POWER INPUT AC/DC Low voltage plug-in transformer or power from access device. EARTH GND 12-24 POWER VAC/VDCINPUT TRANSMITTER OPEN REQUEST NUMBER O OPE pN t iR oE nQ aU lE cST o P nU nS eH cB tU ioTT nO N N C NO. .C OM. . A RC EC LE AS YS ACCESS GRANTED p mr eo tv hid oe ds t oa n a ce tx ivt ae tr en al N C NO. .C OM. . OB RS ET LA AC YLE S OU CS CP UE PN IED DED access device. RADIO Pushbutton or Radio Terminals ACCESS DEVICE ACCESS AND OBSTACLE RELAY TERMINALS Connect to access device. Select Obstacle normally open or normally closed Terminals terminals to match access device.

(619) 438-7000 • FAX (619) 438-7043

Toll Free FAX (800) 468-1340

TRANSMITTER

ACCESS GRANTED

SUSPENDED

Lights when a signal is

NUMBER

OCCUPIED

RADIO

EARTH GND

POWER

INPUT 12-24 VAC/VDC

OPEN REQUEST

ACCESS

RELAY

OBSTACLE

RELAY

SUSPENDED INDICATOR

N.C.

COM

N.O.

N.C.

COM

N.O.

Installation Instructions

For connection of earth ground,

power and open request inputs

plus access and obstacle relay

Control Receiver

Wireless Access

MOUNT RECEIVER

SCREWS PROVIDED

use.

USING THE FOUR

TERMINAL STRIP

Lights when the access

ACCESS GRANTED INDICATOR

or obstacle relay is

AP-1

outputs.

energized.

Show 4 more labels / short text on this page
been suspended from · transmitter that has · ® · received from a
Page 2 of the Linear AP-1 user manual — TO A DISPLAYED NUMBER
Page 2 · click to enlarge
Page 2
LEARNING TRANSMITTERSDELETING TRANSMITTERSSUSPENDING TRANSMITTERS ENTER THE NUMBER (1 TO 169) OF AN EMPTY MEMORY LOCATION PRESS LEARN BUTTON OCCUPIED LIGHT WILL BLINK FOR 2 SECONDS IF MEMORY LOCATION IS EMPTY ACTIVATE THE TRANSMITTER WHILE OCCUPIED LIGHT IS BLINKING OCCUPIED LIGHT WILL LIGHT STEADY WHEN TRANSMITTER IS LEARNEDENTER THE NUMBER (1 TO 169) OF THE MEMORY LOCATION TO CLEAR PRESS DELETE BUTTON OCCUPIED LIGHT WILL BLINK FOR 2 SECONDS IF MEMORY LOCATION IS OCCUPIED PRESS DELETE AGAIN WHILE OCCUPIED LIGHT IS BLINKING TO ERASE TRANSMITTER FROM MEMORY OCCUPIED LIGHT WILL GO OUT WHEN TRANSMITTER HAS BEEN DELETEDENTER THE NUMBER (1 TO 169) OF AN OCCUPIED MEMORY LOCATION OCCUPIED LIGHT WILL LIGHT STEADY FOR 2 SECONDS IF MEMORY LOCATION IS OCCUPIED PRESS SUSPEND BUTTON SUSPENDED AND OCCUPIED LIGHTS WILL LIGHT STEADY WHEN THE TRANSMITTER HAS BEEN SUSPENDED NOTE: TO "UNSUSPEND" THE TRANSMITTER, ENTER SUSPENDED TRANSMITTER NUMBER AND PRESS SUSPEND. LEARNING MGT TRANSMITTERSMGT TRANSMITTER SUPERVISIONSYSTEM TESTING ENTER MEMORY LOCATION NUMBER 999 TO LEARN MGT TRANSMITTER PRESS LEARN BUTTON OCCUPIED LIGHT WILL BLINK FOR 2 SECONDS IF MEMORY LOCATION IS EMPTY ACTIVATE THE MGT TRANSMITTER WHILE OCCUPIED LIGHT IS BLINKING OCCUPIED LIGHT WILL LIGHT STEADY WHEN TRANSMITTER IS LEARNEDIF RECEIVER IS BEEPING EVERY FIVE SECONDS, PRESS #-1 TO DISPLAY THE MGT SUPERVISORY CODES (MULTIPLE CODES CAN BE DISPLAYED) "L" INDICATES A LOW MGT TRANSMITTER BATTERY "F" INDICATES AN MGT TAMPER OR LOOP FAULT CONDITION "S" INDICATES THAT HOURLY STATUS REPORTS HAVE NOT BEEN RECEIVED FROM THE MGT FOR FOUR HOURS AFTER SERVICING FAULT, PRESS OPEN TO SILENCE BEEPER AND RESET THE RECEIVER DISPLAYS NOTE: IF SUPERVISION SOUNDER IS NOT REQUIRED, SUSPEND MGT TRANSMITTER (#999). SUPERVISION CODES CAN STILL BE DISPLAYED. THIS WILL ALSO DISABLE THE REQUIREMENT OF PRESSING A TRANSMITTER TWICE TO TRIGGER THE ACCESS RELAY DURING A SUPERVISORY CONDITION.ACTIVATE A LEARNED TRANSMITTER AND VERIFY THAT THE ACCESS DEVICE OPERATES IF MGT OBSTACLE TRANSMITTER IS USED, RUN ACCESS DEVICE AND TRIGGER OBSTACLE SENSOR. VERIFY THAT ACCESS DEVICE REVERSES IF AN OPEN REQUEST PUSHBUTTON IS INSTALLED, PRESS IT AND VERIFY THAT THE ACCESS DEVICE OPERATES # KEY UTILITIESSPECIFICATIONSLINEAR LIMITED WARRANTY THESE HANDY UTILITY FUNCTIONS CAN SPEED SYSTEM PROGRAMMING AND MAINTENANCE DISPLAYS THE MGT SUPERVISORY CODES DISPLAYS THE NUMBER OF EMPTY MEMORY LOCATIONS DISPLAYS THE NUMBER OF OCCUPIED MEMORY LOCATIONS DISPLAYS THE FIRST AVAILABLE EMPTY MEMORY LOCATION DISPLAYS THE VERSION NUMBER OF THE AP-1 FIRMWARE WHEN DISPLAY IS BLANK, DISPLAYS THE NUMBER OF THE LAST TRANSMITTER ACTIVATED, OR SUBTRACTS 1 FROM THE DISPLAYED NUMBER WHEN DISPLAY IS BLANK, PRESS # BEFORE PRESSING UTILITY FUNCTION NUMBER, OR ADDS 1 TO A DISPLAYED NUMBERSize: 10.5"W x 4.5"H x 2"D Weight: 1.5 Lbs. Supply Voltage: 12-24 Volts AC or DC Operating Current: 250 Ma Maximum Operating Temperature Range: -22° to +158° F (-30° to +70° C) Sensitivity: -94 dBm Minimum Bandwidth (3 db): 4 MHz Typical Frequency: 318 MHz Relay Contact Rating: 1 AMP @ 24 Volts AC or DCThis Linear product is warranted against defects in material and workmanship for twelve (12) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear corporation for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fitness, are valid only until Warranty Expiration Date as labeled on the product. This Linear Corporation Warranty is in lieu of all other warranties express or implied. For warranty service on Linear equipment return product, at sender’s expense to: Linear Corporation Service Department 2580 Pioneer Avenue, Suite C Vista, CA 92083 IMPORTANT !!! Linear radio controls provide a reliable communications link and fill an important need in portable wireless signalling. However, there are some limitations which must be observed. 1 For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited range. 1 A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings. 1 Changes or modifications to the device may void FCC compliance. 1 Infrequently used radio links should be tested regularly to protect against undetected interference or fault. 1 A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users. Copyright © 1995 Linear Corporation 211037 B

TO A DISPLAYED NUMBER

PROGRAMMING AND MAINTENANCE

EMPTY

EMPTY

CODES

Ask about the Linear AP-1

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Linear AP-1

Be the first to ask — other owners or our team will answer.

Original document

Linear AP-1 manual PDF

2 pages·179 KB·Video Game Controller·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…