Contents Introduction The AM3Plus Access Controller is designed for use as a primary access control device for gated communities, parking garages, offi ce buildings, apartments, dormitories, hotels/motels, commercial buildings and recreational facilities. Housed in a lockable, plastic enclosure, the AM3Plus features a 2-digit LED display, nine status indicators, four relay indicators with four relay activation pushbuttons. Three programming buttons, a reset button, and a power indicator are present. The enclosure is monitored with a magnetic “tamper” switch. The system controls its four output relays by responding to various input devices that react to proximity cards, transmitters, and entry codes. The four relay output channels can be programmed to control electric door strikes, magnetic locks, door & gate operators, or barrier gates. Access is granted or denied depending on the current user’s authorization to gain access and system settings that control groups of users or all users. Complete access control event logging, access time restriction, access location restriction, and administration functions are also available to manage the installation. The AM3Plus is network ready. Multiple units can be interconnected on a 3-wire RS-485 network or through modems. The AM3Plus can be used in mixed networks with its sister products, the AE1000Plus and AE2000Plus. Two sets of Wiegand inputs are available for connection to 26, 30, or 31-bit Wiegand devices (card readers, etc.). Two sets of PBUS inputs are available for connection to Linear’s line of remote accessories. The AM3Plus can be powered from a 12-24 Volt AC or DC source. DC power can be obtained from the access device or AC power from a separate power transformer. The system supports and charges a 12-volt backup battery for operation during power outage. Low battery detection circuitry monitors the backup battery’s condition. The EEPROM memory retains all entry codes and programming, even without power.
Introduction 2 Operation 2 Programming and Cardholder Maintenance 2 Hardware Features 3 Software Highlights 3 Feature Overview 3 Accessory Overview 4 PBUS Accessories 4 Wiegand Accessories 4 Component Locations 5 Wiring Diagram 6 Important Mounting Requirements 7 AM3Plus Mounting 8 Relay Output Wiring 9 Power, Battery, & Ground Wiring 10 Telephone Wiring 11 PBUS Accessories 11 Wiegand Accessories 12 RS-232 Port 12 Optional Network Connections 13 System Controls 16 System Diagnostics 17 Specifi cations 18 Troubleshooting 18 Linear Limited Warranty 19 FCC Notice 19
Operation In a typical installation, the unit’s memory would be programmed with each resident’s name and entry code number. Arriving visitors would use a remote keypad to enter their entry code. Also proximity receivers, swipe card readers, and other remote devices can be used with the system. Block coded MegaCode® transmitters can be used to gain access through a remote radio receiver connected to the AM3Plus PBUS. Each transmitter can be individually suspended or re-activated. The system’s clock/calendar can control access based on specifi c times and dates. Automatic relay activation can be scheduled. Access can be restricted to certain times and dates. Holiday access can be scheduled. The system’s event log records system activity for future reference.
Programming and Cardholder Maintenance Two programming methods can be used with the system: Linear’s AXNET or AccessBase2000. Each has its advantages, but only one must be chosen at the onset for each installation. Once a unit is programmed with one method, all programming data will be lost if a decision is made to switch to the other method. Linear’s AXNET software is built into each unit. It allows connecting to the unit using common browser software from any PC at any location. Each unit’s database is stored in the unit’s memory. Linear’s AccessBase2000 software installs in one dedicated PC and is designed with many extra features usually for large network installations. The database for the entire system is stored in the dedicated PC.
Throughout this manual, multiple-unit networks are referenced. Depending on the programming method used, networks can contain the following model units:

Feature Overview Relay Outputs
Four 3-amp dry contact relay outputs are provided to activate four access devices, such as door strikes, magnetic locks, automatic doors, barrier gates, and automatic sliding gates. The relay outputs can also be used for alarm contact shunting, operator obstacle triggering, and alarm activation. Each of the four relays can also be manually activated from buttons on the front of the AM3Plus. LED indicators display the status of each relay. Request-to-Exit Inputs
Each relay has 3-amp @ 24-volt rating with a status indicator and relay latching pushbutton
Activates access device for exiting using a hardwired switch
For sensing door position to control door-ajar and alarm features, or for access inhibit timer
Display access, reader, and system information
Each relay channel has a request-to-exit input. These inputs are supplied for hardwire activation of the access devices. Typically a request-to-exit input is wired to a pushbutton inside of the access controlled area. When a person desires to exit, pressing the pushbutton will activate the output relay channel and trigger the access device. A loop detector for automatic gate operation can be connected to a request-to-exit input. Sensing Inputs
Compatible with the Model ACM-1 plug-in modem for telephone communications with system
RS-232 port for direct connection to printer or computer
Multiple units can be connected together to share data
The sensing inputs connect to door switches that monitor whether the controlled door is open or closed. The sensing inputs may alternately be programmed as “access inhibit” inputs for use with an external timer or service switch. Optional Modem
Model AM-MIO accessory adds additional input and outputs to the AM3Plus
Stamps the event log data as it is stored in the system’s memory
Two Wiegand format card reader inputs for connection to external devices
A modular connector is provided for telephone line connection to the unit’s optional 33.6K baud modem. The system can be accessed remotely for programming and control over the standard telephone system using a personal computer with a modem. For system backup, a computer connected through the modem can store and retrieve the AM3Plus memory data. RS-232 Communications Port
Two PBUS input/output ports for connection to Linear accessories
Built-in backup battery charging circuit
A modular connector is provided for the bi-directional 38.4K baud RS-232 port. The AM3Plus RS-232 port connects to a personal computer’s COM port. System programming can be performed locally with a computer connected to the RS-232 port. Obstacle Detection
AC power input is monitored, power outages are recorded in the event log Software Highlights
No dedicated programmer required, program with a computer and a modem
Linear’s Model MGT safety edge transmitter is compatible with the AM3Plus. The MGT detects and transmits obstacle events to a remote receiver connected to the AM3Plus. Programming Memory
Up to 20,000 entry codes can be used for gaining access
Flexible code length for different applications
The AM3Plus fl ash memory retains all entry codes, transmitter information, card access, and programming, even without power. Battery Backup
Up to 45,600 block coded and 20,000 individually enrolled Linear transmitters can be used for gaining access
The system supports a 12-volt battery backup for operation during power outage. The system will charge the backup battery when AC power is present. Network Support
Identifi es wireless transmitters by installation
Up to 45,600 block coded and 20,000 individu- ally enrolled cards can be used for gaining access
Multiple AE1000Plus, AE2000Plus, & AM3Plus units can be networked together via three-wire RS-485 cables or through modems allowing information sharing between the units. A common event log is retained for all of the networked units. Linear PBUS Ports
Each output’s action is programmable
Activation for up to four time periods for each of the 31 system time zones
Two 6-wire Linear PBUS input/output ports are available to connect to several accessories (keypads, proximity readers, remote receivers). A typical application for a remote keypad or reader would be to control additional doors or gates.
Validation during four time periods for each of the 31 system time zones
Select days of the week access is allowed
Select up to 24 expiring & 24 non-expiring holidays for access restriction
Compatible with Linear’s Model MGT transmitter
Stores up to 20,000 system events in memory for record keeping
System logs deleted cardholders for future identifi cation
Options to temporarily disable a cardholder’s credentials after access for a preset time or depending on the cardholder’s access direction
Hardware Features

Accessory Overview PBUS Accessories Several compatible accessories are available to connect to the two 6- wire communications “PBUS” inputs. Up to six PBUS accessories can be used with each AM3Plus unit.
AM-RRR Remote Radio Receiver For wireless transmitters, connect the Model AM-RRR high-gain superheterodyne UHF receiver. The receiver is housed in a weather-resistant enclosure and can be mounted indoors or outdoors. Gaskets and a weather-tight wiring strain relief seal the unit from the elements. AM-RPR Remote Proximity Receiver The Model AM-RPR functions as a remote device that supplies localized radio reception for the AM3Plus In a typical installation, the AM-RPR would be mounted in a plastic single-gang electrical box next to the controlled opening. When the user requires access, their transmitter must be activated within three inches of the AM-RPR faceplate. AM-KP Exterior Keypad The Model AM-KP is housed in a rugged cast aluminum enclosure designed for exterior installations. The die-cast keys have bright, easy-to-read yellow graphics. The keypad can be mounted to a pedestal or directly to a wall. A keylock secures the keypad to the mounting backplate. AM-KPI Interior Keypad The Model AM-KPI keypad is housed in a rugged, plastic enclosure designed to be mounted indoors in a standard single-gang electrical box. Tamper resistant screws secure the keypad to its mounting plate. The die-cast keys have bright, easy-to-read yellow graphics and is illuminated with white LEDs. The keypad is supplied with a satin-chrome bezel and three interchangeable colored bezels (white, ivory, & bronze) to customize the keypad appearance for the installation. AM-CRI Card Reader Interface The Model AM-CRI expands the standard two AM3Plus Wiegand inputs by supporting one or two additional 26-bit Wiegand input devices per AM-CRI interfaces used.
AM-RRR
RADIO RECEIVER
AM3PLUS ACCESS CONTROLLER
AM-RPR
AM-KP
PBUS ASSESSORIES
WIEGAND ACCESSORIES
AM-KPI
AM-KPI INTERIOR
AM-CRI AM-PR PROXIMITY
KEYPAD
READERS
Wiegand Accessories The two WIEGAND format inputs connect WIEGAND devices to the AM3Plus. Linear offers a Wiegand format proximity reader. Most other manufacturer’s 26, 30 & 31-bit WIEGAND output devices can also be used with the AM3Plus.
AM-PR Proximity Reader The Model AM-PR is a radio-based reader that works with either proximity tags (Model AM-PT) or proximity cards (Model AM-PC), both of which are slotted to attach to key rings. Upon reading a user’s tag or card, the reader sends the entry data via a Wiegand output to the AM3Plus. An integral LED confi rms to the user that access is granted.
KEYPAD
WIEGAND
CARD READERS
AM-PR
AM-RPR
RADIO PROXIMITY
AM-CRI
CARD READER INTERFACE
RECEIVER
* · 0 #



Mounting Environment Consider the environmental factors at the desired mounting location. Although the exterior keypads are designed for direct outdoor installations, it is necessary to protect the AM3Plus from extreme exposure to sun, driving rain, or snow. Mounting the unit in a kiosk can provide extra environmental protection. Use a Model CAB-3 (P/N ACP00913) cabinet for mounting the AM3Plus outdoors.
Follow Building Codes Check all local building codes and ordinances prior to installing the system. Proper installation of the AM3Plus conforming to the local building codes for access control equipment is a regulatory requirement. The AM3Plus and remote keypad installation is an extremely important and integral part of the overall access control system.
?
?
?
?
?
Mounting Location If the AM3Plus is used to control a door or pedestrian gate, locate the remote keypad as near as practical to the entry point. If the unit is mounted on or in a wall adjacent to the entry point, be sure the wall is sturdy. The repeated shock and vibration from a slamming access door or spring-loaded pedestrian gate must be isolated from the keypad. NEVER MOUNT THE KEYPAD DIRECTLY TO A MOVING DOOR OR GATE!
Gate Installations If the AM3Plus is used to control a gate operator connected to a vehicular gate, the remote keypad MUST be mounted AT LEAST 10 feet away from the gate (open and closed) and gate operator. AT NO TIME SHOULD A PERSON BE ABLE TO TOUCH THE GATE OR GATE OPERATOR AND THE KEYPAD AT THE SAME TIME.
Vehicle Traffi c Do not mount the remote keypad where it extends into any traffi c lane. Locate the gooseneck pedestal or entry kiosk so all parts of the keypad are outside the traffi c lane. Locate the keypad clear of any turn-around lanes vehicles use when access is denied.
EDGE OF TRAFFIC LANE
Americans with Disability Act (A.D.A.) Requirements THE FOLLOWING WHEELCHAIR ACCESS REQUIREMENTS ARE FOR PUBLIC DOOR CONTROL INSTALLATIONS ONLY.
1. If the clear fl oor space allows only forward approach to the keypad, the maximum high forward reach allowed is 48” above grade to the top of the keypad. 2. If the high forward reach to the keypad is over an obstruction of greater than 20” but less than 25”, the maximum high forward reach allowed is 44” above grade to the top of the keypad. 3. If the clear fl oor space allows parallel approach by a person in a wheelchair, the maximum high side reach shall be 54” above grade to the top of the keypad. 4. If the high side reach is over an obstruction of 24” or less, the maximum high side reach allowed is 46” above grade to the top of the keypad.

AM3Plus Mounting Standard Cabinet The AM3Plus cabinet is designed to be mounted directly to a wall or fl at surface. Wiring access for power, telephone, earth ground, control output must be available at the mounting location. For easier wiring, choose a well lit location. Wiring access for remote accessory cables must also be available at the mounting location.

FOR CONDIUT WIRING, PUNCH OUT REQUIRED KNOCKOUTS AND INSTALL 3/4" CONDUIT HUBS IN HOLES
1. Flip the cabinet’s cover up to unlock the hinges and remove the cover from the case. 2. To make cabinet mounting easier, the AM3Plus can be removed from the cabinet (optional). 3. If using conduit for wiring, punch out the selected cabinet wiring knockouts. 4. Use the cabinet as a template and mark the locations for the four cabinet mounting screws in the keyhole slots. 5. Mark the wiring access slot if the wiring is being routed from behind the cabinet. 6. Use a hole saw to cut out the location for the wiring access slot (if used). 7. Use four screws and appropriate screw anchors to mount the cabinet to the wall. 8. If the AM3Plus was removed to mount the cabinet, replace the AM3Plus. 9. After the installation’s wiring and programming are complete, replace the cabinet’s cover and secure it with the two screws provided. Outdoor Cabinet To protect the unit outdoors, the AM3Plus can be mounted inside a Linear Model CAB-3 (P/N ACP000913) outdoor metal cabinet. Wiring access for power, telephone, earth ground, control output must be available at the mounting location. For easier wiring, choose a well lit location. Wiring access for remote accessory cables must also be available at the mounting location.

FOR CONDUIT WIRING, REMOVE ANY CABINET KNOCKOUTS BEFORE MOUNTING THE CABINET
USE THE CABINET BOTTOM AS A TEMPLATE TO MARK THE FOUR KEYHOLE MOUNTING HOLES
FOR RECESSED WIRING, MARK WIRING SLOT, THEN CUT OUT HOLE WITH DRYWALL SAW
1. Open the cabinet’s cover and push it in to latch it open. 2. Punch out the selected cabinet wiring knockouts. 3. Use the cabinet as a template and mark the locations for the four cabinet mounting screws. 4. Use four screws and appropriate screw anchors to mount the cabinet to the wall. 5. Mount the AM3Plus inside the cabinet with four 6-32 screws. 6. After the installation’s wiring and programming are complete, lower the cabinet’s cover and secure it with a lock.

AM3PLUS MOUNTS IN CAB-3 CABINET WITH FOUR 6-32 SCREWS

Relay Output Wiring Any of the four relay outputs channels (A-D) can be used to control access devices on doors or gates.

Door or Pedestrian Gate Control
1. Install a low voltage electric door strike or magnetic lock as a locking device for the door or pedestrian gate. 2. Install the power supply or transformer for the locking device. DO NOT POWER THE AM3Plus FROM THIS POWER SUPPLY. 3. Connect one wire from the power supply to one wire from the locking device. 4. Route two wires between the locking device and the AM3Plus. Connect one wire to the remaining wire of the locking device. Connect the other wire to the remaining wire of the power supply. 5A. For a door strike, connect the wires to the AM3Plus relay COM & N.O. terminals. 5B. For a magnetic lock, connect the wires to the AM3Plus relay COM & N.C. terminals. Gate Control
wiring diagram.
Request-to-Exit Inputs Each of the four relay outputs has a request-to-exit input terminal. Grounding this terminal will activate the associated relay. Exit request inputs are typically used with push bars, loop sensors, or pushbuttons.



16 VAC 20 VA TRANSFORMER
BATTERY TERMINALS
BAT
BAT
clock/calendar and programming memory during power outages. 1. Route two battery leads between the AM3Plus and the backup battery. 2. Connect the Battery positive to the AM3Plus BAT+ terminal and the negative to the BAT- terminal. ✦ NOTE: The AM3Plus supplies battery charging current. An
external battery charger is not required to maintain the battery.
Earth Ground For the best ground, use size 12 gauge solid wire or larger to connect the to an 8-foot copper ground rod. Locate the ground rod next to the Power and Telephone company rods and bond the rods together with a new clamp. Do not disturb the clamps installed by the Power or Telephone Company. Alternately, connect to a metallic cold water pipe for the earth ground.
GND. GND.
STAKE

Telephone Wiring For programming, the AM3Plus connects to a standard telephone line.
telephone communications to the AM3Plus controller.
INCOMING DEDICATED TELEPHONE
LINE JACK
MODULAR TELEPHONE CORD
PBUS Accessories Up to six accessories (keypads, proximity readers, remote receivers) can be connected to the two PBUS input/output ports. A typical application for a remote keypad would be to control a second door or gate. Linear’s PBUS devices compatible with the AM3Plus are:
PWR
GND DAT1 DAT0 DVAL PCLK
REMOTE
PCLK DVAL DAT0 DAT1
PBUS TERMINALS
PBUS DEVICE
ORANGE & ORANGE-WHITE
CAT-5e WIRING EXAMPLE ORANGE & ORANGE-WHITE
BROWN & BROWN-WHITE
Cable choices:
PWR
GND DAT1 DAT0 DVAL PCLK
GND DAT1 DAT0 DVAL PCLK
GREEN-WHITE
GREEN-WHITE
GREEN
GREEN
BLUE
BLUE
BLUE-WHITE
BLUE-WHITE
REMOTE PBUS DEVICE TERMINALS
ACCESS CONTROL SYSTEM
CAT-5e 4-UTP CABLE UP TO 500 FEET PER DEVICE

Wiegand Accessories The two AM3Plus Wiegand inputs (READER A & B) can connect to a large variety of 26, 30, and 31-bit Wiegand output accessories. The Wiegand format is a common standard for access control equipment. A typical application would be to add swipe card or proximity readers to the system.
PWR PWR
DAT0
DAT1
LED1
HOLD
LED2
GND
READER TERMINALS
REMOTE WIEGAND
DEVICE
RS-232 Port A modular connector is provided for the bi-directional 38.4K baud RS-232 port. The AM3Plus RS-232 port connects to a personal computer’s COM port. System programming can be performed locally with a computer connected to the RS-232 port.
COMPUTER'S
COM PORT
SET COMPUTER COM PORT
BAUD RATE TO 38,400 BPS
LINEAR MODEL A2C SERIAL COMPUTER CABLE

Optional Network Connections Linear’s AM3Plus, AE1000Plus, & AE2000Plus Access Control Systems can be connected together in a network. A network will allow sharing programming and user information between the systems. Program each unit to a different network Node Address (see Page 16).
access control Models AE-1000, AE-2000, & AM3 can be used in networks with the Models AE1000Plus, AE2000Plus, & AM3Plus only using AccessBase2000 software. The built-in AXNET Browser Interface included in the “Plus” models is only compatible with the Models AM3Plus, AE1000Plus, and AE2000Plus.
Network Confi gurations for AXNET Programming If the system is going to be programmed using Linear’s AXNET Browser Interface, units can communicate with each other on the network through modems or RS-485 cable connections. Refer to the fi gure below for details of the 11 supported AXNET network hardware confi gurations and associated Network Confi guration Numbers. After choosing a network layout that best suits the installation, note the Network Confi guration Number. This number is required to be entered during setup of the AXNET Browser Interface in the Global Settings for Networking area.

NETWORK CONFIGURATION #9 2X TWO RS-485 NODES, TWO MODEM NODES

Optional Network Connections (Continued) Network Confi guration for AccessBase2000 Programming If the system is going to be programmed using Linear’s AccessBase2000 software, units communicate with each other on the network through RS-485 cable connections. AccessBase2000 does not support unit-to-unit network communications through modems, only RS-485 cable. AccessBase2000 does support modem communications from the PC to the eight Node #1 “master” units on an AccessBase2000 network. Refer to the fi gure below for design details of a fully implemented AccessBase2000 network. The fi gure shows eight networks, each with eight nodes, for a total of 64 units.


Optional Network Connections (Continued) RS-485 Network Wiring Network wiring conforms to 3-wire RS-485 electrical specifi cations. Units connected in the network can be wired using one unit as a “hub” or by wiring from one unit to the next in “daisy-chain” fashion. See the fi gures for wiring options.

ACCESS CONTROL HOMERUN NETWORK USING ONE UNIT AS A NETWORK MASTER
terminals.
Network Wiring with Hub

Network “Daisy-chain” Wiring

System Controls Pushbuttons Refer to the fi gure for the location of each of the eight pushbuttons.
DISPLAY
"UP" BUTTON
SYSTEM RESTART
BUTTON
"ENTER" BUTTON
RELAY "A"
RELAY "B"
RELAY "C"
RELAY "D"
LATCH
LATCH
LATCH
LATCH
STATUS/PROGRAM
DISPLAY
1. To enter Program Mode, press and hold the UP and DOWN pushbuttons together for one second. While in Program Mode, both decimal points on the display are lit. 2. The display shows the current network node number setting. 3. Press the UP or DOWN button to cycle the display through the options that can be selected (see Program Mode Display Table). 4. When the desired option is displayed, press the ENTER button to select the option. ✦ NOTE: In network installations, a unique network address
RIGHT DIGIT SHOWS NETWORK NODE ADDRESS
LEFT DIGIT CIRCULATES
PROGRAM MODE
(1-8 for AccessBase2000, 1-4 for AXNET) must be set before communicating with network. ✦ NOTE: If using AXNET for programming the system, select the
An programming option, for AccessBase2000 select Ab. After the option is selected, the system will restart. Status Mode While the system is running, the display will show the current system status. Normally the left digit will show a moving pattern and the right digit will show the unit’s Network Node number. When a supervisory condition exists, the display will cycle to show the condition(s). When an item is displayed, press the ENTER button to clear the display (clears the display only, the condition may still exist). Refer to the following table for the supervisory condition display codes.
DIGITS SHOW SUPERVISORY CODE
PROGRAM MODE DISPLAY
AccessBase2000 MODE AXNET MODE FUNCTION
STATUS MODE DISPLAY DISPLAY CONDITION 01 MGT TRANSMITTER STATUS EXCEPTION 02 MGT TRANSMITTER LOW BATTERY 03 MGT TRANSMITTER TAMPER 04 AC POWER FAIL (BACKUP BATTERY REQUIRED) 05 CHANNEL “A” LOCKED CLOSED 06 CHANNEL “B” LOCKED CLOSED 07 CHANNEL “C” LOCKED CLOSED 08 CHANNEL “D” LOCKED CLOSED 09 MODEM FAILURE
A.N. A.b. SWITCH OPERATION MODE
B.L. B.L. RESERVED (DO NOT USE)
C.L. C.L. CLEAR UNIT’S MEMORY

System Diagnostics Several indicators on the AM3Plus are for monitoring the system during operation. When calling for technical assistance, Linear’s Technical Services Department may ask the installer to use these indicators to diagnose the system.
NETWORK
DECODE
NETWORK
HOST ON-LINE
VALIDATE
Indicators 15 LED indicators are on the AM3Plus. Refer to the fi gure for the location of each indicator.
READER "A"
DISPLAY
BACKUP BATTERY
READER "B" P-BUS
POWER
LOW
RELAY "B"
RELAY "C"
RELAY "D"
ACTIVE
ACTIVE
ACTIVE
ACTIVE

MECHANICAL Case dimensions: 11.5” W x 12.5” H x 3.5” D ELECTRICAL Voltage: 16-24 Volts AC or 12-24 Volts DC Current: 850 mA maximum @ 12 Volts DC Backup Battery: 12 Volt DC Outputs: Relay Channels A-D Form “C” 3 Amps @ 30 Volts maximum Inputs: Four normally closed door sense inputs Four normally open request-to-exit inputs Two WIEGAND reader inputs Two PBUS inputs Network: Three-wire network ENVIRONMENTAL Temperature: -22°F to 149°F (-30°C to 65°C) Humidity: 5% to 95% non-condensing

Linear Limited Warranty This Linear product is warranted against defects in material and workmanship for twenty-four (24) months. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear Corporation for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until the warranty expires. This Linear Corporation Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
FCC Notice Changes or modifi cations not expressly described in this manual or approved by the manufacturer could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: