EN
Linear logo
Official user manual

Linear Access Control Keypad (AM-KPI)

2 pages·1016 KB·Door·PDF·ENDEFRITNLJA
Linear Access Control Keypad (AM-KPI)
Table of Contents 52 sections ADDRESS · SELECTOR · DEVICE · PBUS · … ShowHide
Page 1 of the Linear Access Control Keypad (AM-KPI) user manual — FACEPLATE HERE
Page 1 · click to enlarge
Page 1

ADDRESS

SELECTOR

DEVICE

PBUS

"LOCKOUT"

YELLOW

AM-KPI Access Control Keypad Installation Instructions USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - Toll Free FAX (800) 468-1340 www.linearcorp.com1. INTRODUCTION2. KEYPAD FEATURES The Model AM-KPI keypad is designed for use with Linear’s AE1000Plus, AE2000Plus, and AM3Plus access control systems. The keypad is housed in a rugged, plastic enclosure and is designed to be mounted indoors in a standard single-gang electrical box. Tamper resistant screws secure the keypad to its mounting plate. The die-cast keys have bright, easy-to-read yellow graphics. The keypad is supplied with a satin-chrome plastic bezel installed. Three interchangeable colored plastic bezels (white, ivory, & bronze) are included with the unit to customize the keypad appearance for the installation. All system indicators and lights are long-lasting, solid-state LEDs. Two indicators show the status of the entry system. The left indicator lights red to indicate power, then turns green when access is granted. The right indicator lights yellow when the keypad is in “lockout” condition (from too many incorrect code entries). A white LED downlight lights the keypad for nighttime use. An internal sounder beeps when each key is pressed. The AM-KPI is normally powered from the controller. Alternately, the keypad can be powered locally with a 12 VDC power supply. Robust static and lightning protection circuits safeguard the keypad’s electronics. A rotary switch selects the keypad’s PBUS device address. Each device connected to the controller must be set to a different PBUS device address.RED/GREEN YELLOW POWER/ACCESS "LOCKOUT" INDICATOR INDICATOR BEZEL SOLID STATE WHITE LED PBUS DOWN LIGHT DEVICE ADDRESS SELECTOR FACEPLATE KEYPAD TERMINAL BLOCK MOUNTING PLATE 3. OPEN THE KEYPAD4. CUSTOMIZE THE BEZEL (OPTIONAL)5. INSTALL WALL BOX & MOUNTING PLATE

2. KEYPAD FEATURES

POWER/ACCESS

RED/GREEN

1. INTRODUCTION The Model AM-KPI keypad is designed for use with Linear’s

AE1000Plus, AE2000Plus, and AM3Plus access control systems. The

device address.

key is pressed.

installation.

electronics.

ASSEMBLY

KEYPAD

REMOVE THE

FACEPLATE

MOUNTING PLATE

FROM THE KEYPAD

SEPARATE THE

USA & Canada (800) 421-1587 & (800) 392-0123

MOUNTING

(760) 438-7000 - Toll Free FAX (800) 468-1340

PLATE

www.linearcorp.com

FACEPLATE HERE

PRY UP THE

TWO SCREWS

AM-KPI

REMOVE THE

Installation

Instructions

Control

Keypad

Access

Page 2 of the Linear Access Control Keypad (AM-KPI) user manual — PROGRAM THE CONTROLLER
Page 2 · click to enlarge
Page 2

TWO SCREWS

OF THE KEYPAD

2 INSTALL THE

SNAP THE TOP

INTO PLACE

6. ROUTE THE CABLE7. CONNECT THE CABLE & SET THE DEVICE ADDRESS8. MOUNT THE KEYPAD EACH AM-KPI KEYPAD EQUALS 9 LOAD UNITS CABLE LENGTH FORMULA FOR EACH KEYPAD USED IN THE SYSTEM CABLE RUN CABLE TYPE FORMULA 300 FEET MAXIMUM BELDEN 9931 (24 AWG) FEET x LOAD UNITS < 3,000 MAXIMUM 500 FEET MAXIMUM WEICO 9405 (20 AWG) FEET x LOAD UNITS < 10,000 MAXIMUM HOMERUN WIRE FROM THE CONTROLLER TO EACH KEYPAD’S LOCATION (1000 FEET WIRE MAXIMUM ALLOWED IN THE SYSTEM)FOLLOW THIS WIRING DIAGRAM TO CONNECT THE KEYPAD TO THE CONTROLLER PWR PWR GND GND ACCESS CONTROL AM-KPI DAT1 DAT1 SYSTEM PBUS TERMINALS DAT0 DAT0 TERMINALS DVAL DVAL PCLK PCLK EACH REMOTE DEVICE MUST BE SET TO A UNIQUE NUMBER FROM 1 TO 6 SET THE DEVICE ADDRESS SWITCH CAUTION TO PROTECT THE KEYPAD FROM STATIC DISCHARGES, BE SURE EARTH GROUND IS CONNECTED ARROW ON SWITCH SLOT TO THE CONTROLLER POINTS TO THE NUMBER FOR LOCAL POWER, DISCONNECT RED WIRE FROM "PWR" CONNECTION ON AM-KPI AND CONNECT EXTERNAL 12 VDC POWER SUPPLY (+ TO PWR & - TO GND) NOTE: CONTROLLER MUST STILL BE CONNECTED TO AM-KPI "GND"1 HOOK THE KEYPAD ASSEMBLY ONTO THE MOUNTING PLATE 2 INSTALL THE TWO SCREWS 3 FIT THE BOTTOM TAB OF THE FACEPLATE INTO THE SLOT ON THE KEYPAD 4 SNAP THE TOP OF THE KEYPAD INTO PLACE 9. PROGRAM THE SYSTEM10. TEST THE KEYPADLINEAR LIMITED WARRANTY

HOOK THE KEYPAD ASSEMBLY

ONTO THE MOUNTING PLATE 1

6. ROUTE THE CABLE 7. CONNECT THE CABLE & SET THE DEVICE ADDRESS 8. MOUNT THE KEYPAD
CABLE RUN CABLE TYPE FORMULA 300 FEET MAXIMUM BELDEN 9931 (24 AWG) FEET x LOAD UNITS < 3,000 MAXIMUM 500 FEET MAXIMUM WEICO 9405 (20 AWG) FEET x LOAD UNITS < 10,000 MAXIMUM

FOLLOW THIS WIRING DIAGRAM

TO THE CONTROLLER

ADDRESS SWITCH

CAUTION

SET THE DEVICE

PCLK DVAL DAT0 DAT1 GND PWR

TERMINALS

AM-KPI

CABLE LENGTH FORMULA FOR EACH KEYPAD USED IN THE SYSTEM

300 FEET MAXIMUM BELDEN 9931 (24 AWG) FEET x LOAD UNITS < 3,000 MAXIMUM

500 FEET MAXIMUM WEICO 9405 (20 AWG) FEET x LOAD UNITS < 10,000 MAXIMUM

PROGRAM THE CONTROLLER

TO CONFIGURE THE PBUS

CABLE RUN CABLE TYPE FORMULA

EACH AM-KPI KEYPAD EQUALS 9 LOAD UNITS

HOMERUN WIRE FROM THE

CONTROLLER TO EACH

(1000 FEET WIRE MAXIMUM

ALLOWED IN THE SYSTEM)

KEYPAD’S LOCATION

DEVICE

PROGRAMMING INSTRUCTIONS

REFER TO THE CONTROLLER

FOR DETAILS

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Linear Access Control Keypad (AM-KPI)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Linear Access Control Keypad (AM-KPI)

Be the first to ask — other owners or our team will answer.

Original document

Linear Access Control Keypad (AM-KPI) manual PDF

2 pages·1016 KB·Door·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…