Installation and Programming Instructions
(760) 438-7000 USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340



Figure 1. Component Locations
TYPICAL DOOR INSTALLATION WIRING
TERMINAL
BLOCK 1 AK-21W TERMINALS
TERMINAL
BLOCK 2


1 - AC OR DC
SENSE - 8
2 - AC OR DC
COM - 7
POWER
MAIN RELAY
4 - COM
5 AMPS @ 28 VDC MAX.
AUXILIARY RELAY 1 AMP @ 28 VDC MAX.
7 - COM
OUTPUT #4 - 2
CAUTION
REQUIRED WIRING
IF THE UNIT IS AC POWERED, MAKE SURE THE SECONDARY OF THE
SYSTEM TRANSFORMER IS ISOLATED
OTHER WIRING
FROM EARTH GROUND
Figure 2. Wiring Diagram

INSTALLATION Before installing the keypad, the unit must be partially disassembled to access the mounting plate.
Final Keypad Installation After wiring the keypad (see next page), complete the installation by securing the keypad to the mounting plate.
❑ If a lower beeper sound level is required, before installing
Opening the Keypad The keypad assembly is secured with two tamper-resistant screws. Refer to Figure 3 for disassembly details.
the keypad, remove Jumper JP1 (place the jumper block on one pin to save the jumper). ❑ Hook the keypad assembly onto the mounting plate tab (see
❑ Use the special allen wrench (supplied) to remove the two
Figure 5). ❑ Use the special allen wrench (supplied) to install the two
tamper-resistant screws. ❑ Separate the mounting plate from the keypad assembly.
tamper-resistant screws. ❑ Fit the bottom tab on the faceplate into the slot on the
keypad then snap the top of the faceplate in.
HOOK THE KEYPAD ASSEMBLY ONTO THE MOUNTING PLATE 1 2
REMOVE THE TWO SCREWS
MOUNTING
PLATE
SEPARATE THE MOUNTING PLATE AND PLASTIC ENCLOSURE FROM THE KEYPAD
Figure 3. Opening the Keypad
FIT THE BOTTOM TAB OF THE FACEPLATE INTO THE SLOT ON THE KEYPAD
Figure 5. Connecting the Keypad to the Mounting Plate
Install the Electrical Box and Mounting Plate The keypad is designed to fi t into a single-gang electrical box. The box must be deep enough to accomodate the protective plastic enclosure. Select a location near the controlled door and choose a convenient height for the keypad. Be sure there is good wiring accessibility for the unit’s power and the output to the door strike or access device.
Faceplate Removal Refer to Figure 6 for details on removing the faceplate if keypad service is required.
❑ Install the electrical box in the wall. ❑ Place gasket on protective plastic enclosure and insert into
electrical box. ❑ Screw the mounting plate onto the electrical box (see
Figure 4).
INSTALL A SINGLE-GANG ELECTRICAL BOX AT THE PROPER LOCATION FOR THE KEYPAD
PLACE GASKET ON PROTECTIVE PLASTIC ENCLOSURE AND INSERT INTO ELECTRICAL BOX
MAKE SURE THE TAB IS UP
Figure 6. Removing the Faceplate
ATTACH THE MOUNTING PLATE TO THE ELECTRICAL BOX
Figure 4. Installing the Mounting Plate

Keypad Wiring See Figure 7 for an example of a basic door installation. The keypad is mounted adjacent to the door. An electric door strike is mounted in the door jamb to release the door lock. A magnetic switch is mounted on the top of the door jamb for detecting when the door is open. Use the following steps to wire the keypad. Refer to the wiring diagram shown in Figure 8 to assist in the wiring.

☞ NOTE: Up to 500 feet of 18 AWG wire can be run for power, use larger wire for longer runs. Use 22 AWG or larger (depending on the load) for other connections.
OUTPUT ❑ Install a low voltage electric door strike for unlocking the
door. ❑ Route two wires between the door strike and the keypad
box. Connect one of the door strike wires to the keypad’s MAIN RELAY N.O. terminal (TB2 #3). Connect the other door strike wire to the keypad’s AC/DC + terminal (TB2 #1). Connect a wire between the keypad’s AC/DC - terminal (TB2 #2) and the MAIN RELAY COM terminal (TB2 #4).
POWER ❑ Choose a location for the power supply or transformer. ❑ Route two wires between the power supply and the keypad
box. Connect the power supply’s output terminals to the keypad’s AC/DC input terminals (TB2 #1 & #2). Observe wiring polarity if using DC. ✦ CAUTION: If the unit is AC powered, make sure the
secondary of the system transformer is isolated from earth ground.
EARTH GROUND ❑ To avoid damage to the unit from static discharges, connect
the EARTH GROUND terminal (TB1 #5) to a good earth grounding point. Suggested wiring size is 18 AWG for earth ground.
SENSE INPUT ☞ NOTE: SENSE terminal (TB1 #8) can be programmed for either a door sense or inhibit input. Both features cannot be used at the same time. ❑ To use the door sense feature to detect forced entry or door
ajar conditions, install a normally closed door switch on the door and route two wires from the switch to the keypad box. Connect the door switch to the keypad’s SENSE terminal (TB1 #8) and COM terminal (TB1 #7). ❑ If an inhibit switch or timer is going to be used for
temporarily disabling the keypad, route two wires from the switch or timer to the keypad box. Connect the inhibit switch/timer normally open terminals to the keypad’s SENSE (TB1 #8) and COM (TB1 #7) terminals.
OUTPUT #3 LIGHTS AN LED OUTPUT #4 LIGHTS AN LED AND SOUNDS A BEEPER
REQUEST-TO-EXIT INPUT (wiring shown on Page 1, Figure 2) ❑ If a request-to-exit pushbutton is going to be used, route two
1K Ω @ 12 volts 2K Ω @ 24 volts
wires from the keypad box to a normally open pushbutton mounted on the secure side of the door. Connect the wires to the pushbutton and to the keypad’s EXIT (TB1 #6) and COM (TB1 #7) terminals.
Solid State Outputs The two solid state outputs (Output #3 & Output #4) can be programmed to activate during various conditions. These outputs can be used to activate indicators or sounders. See Figure 9 for wiring examples using the solid state outputs.
OUTPUT #3 LIGHTS A LAMP POWERED FROM AN EXTERNAL SOURCE OUTPUT #4 TRIGGERS A NORMALLY OPEN ALARM PANEL ZONE

Adding a New Entry Code
MASTER PROGRAMMING CODE 123456 ENTRY CODE LENGTH 4 DIGITS REQUEST-TO-EXIT OUTPUT RELAY MAIN RELAY ALARM SHUNT OUTPUT DISABLED FORCED ENTRY OUTPUT OUTPUT #3 DOOR AJAR OUTPUT OUTPUT #4 MAIN RELAY ON TIME 2 SECONDS AUXILIARY RELAY ON TIME 2 SECONDS SOLID STATE OUTPUT #3 ON TIME 2 SECONDS SOLID STATE OUTPUT #4 ON TIME 2 SECONDS DOWNLIGHT ON TIME 2 MINUTES DOOR SENSE/INHIBIT INPUT DOOR SENSE KEYPAD LOCKOUT OUTPUT DISABLED KEYPAD ACTIVE OUTPUT DISABLED BEEPER SOUNDS WHEN KEY PRESSED YES BEEPER SOUNDS DURING RELAY #1 NO BEEPER SOUNDS DURING RELAY #2 NO BEEPER SOUNDS DURING OUTPUT #3 NO BEEPER SOUNDS DURING OUTPUT #4 NO KEYPAD LOCKOUT COUNT 3 TRIES BEFORE LOCKOUT ANTI-PASSBACK TIME NO ANTI-PASSBACK AUTO-RELOCK ON BASIC PROGRAMMING When the AK-21W is in Programming Mode, both indicators will turn off until programming begins. After a programming option number is entered the yellow indicator will blink. This shows that the AK-21W is ready to accept the new programming data. After the new data entry is complete, the yellow indicator will fl ash while the data is being stored. The green indicator will light if the data is accepted. The red indicator will light if any programming data is entered incorrectly, and the command will have to be fully re-entered.
Code = The new entry code: 1-999999, depending on code length
Action = Relay output entry code will activate as follows: 1 = Relay #1, timed open 2 = Relay #2, timed open 3 = Both Relays, timed open 10 = Relay #1, toggled 20 = Relay #2, toggled 30 = Both Relays, toggled 12 = Relay #1 toggled; Relay #2, timed open 21 = Relay #1 timed open; Relay #2 toggled The yellow LED will fl ash quickly while the AK-21W searches its memory for available space and duplicate entries. The green LED will light when the new code is stored. If the new entry code chosen is already being used for another entry code, the red LED will light. A new unique code needs to be entered. ☞ NOTE: Leading zeros (zeros before the code number, i.e. 0001) do not need to be entered when programming a new entry code. The AK-21W will internally add any zeros to fi ll all digits determined by the entry code length setting. Leading zeros will have to be entered by the user when entering their code to gain access.
Erasing a Single Entry Code
Code = The entry code to delete. The yellow indicator will fl ash quickly while the AK-21W searches its memory for the code to erase. The green indicator will light when the code is erased.
Erasing All Entry Codes
REMOVE ALL ENTRY CODES FROM THE MEMORY.
Entering Programming Mode The 6-digit Master Programming Code (default = 123456) is used to enter Programming Mode.
Press: 9 7 # 0 # 0 #
☞ NOTE: The green indicator will light while the memory is being erased. This may take up to 15 seconds.
Master Code = the current 6-digit Master Programming Code
Changing the 6-Digit Master Programming Code
Press: * * #
Master Code = The new 6-digit Master Programming Code
The red indicator will light after exiting Programming Mode. ☞ NOTE: The AK-21W will automatically exit Programming Mode after two minutes of inactivity.
Re-entering a Command After a Mistake If the red indicator lights, signaling an incorrect entry, or an incorrect key is pressed during programming, to clear the keypad and re-enter the command:
Length = 1 - 6 for entry code length ☞ NOTE: If the Entry Code Length is going to be changed from the factory default of four digits, make this change fi rst, before programming any entry codes.
Exiting Programming Mode

PROGRAMMING OPTIONS There are several AK-21W programming options. For most installations, the factory set default options are suffi cient. The keypad must be in Programming Mode to make these changes.
Select Request-to-Exit Output Default: Main Relay Sets which output activates when the Request-to-Exit input is grounded. This output may be timed or toggled.
Select Door Sense or Inhibit Input Default: Door Sense The input on Terminal Block TB1, Terminal #8 can be programmed for DOOR SENSE or INHIBIT.
Output = Output to Activate (0-4) 1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output
Main Relay On-time Default: 2 Seconds Sets the length of time the Main Relay activates when triggered.
Input = 0 for Door Sense, = 1 for Inhibit When programmed for DOOR SENSE, if an open condition on the input occurs before access is granted (with an entry code or with the request-to-enter input) a FORCED ENTRY output will occur. If an open condition remains 60 seconds after a relay activation for access, a DOOR AJAR output will occur. When programmed for INHIBIT, a closed condition on the input will prevent Relay #1 from activating when access is requested with an entry code. This mode is typically used with an external timer to disable the access device at certain times.
Seconds = Output time in seconds (0-60)
Auxiliary Relay On-time Default: 2 Seconds Sets the length of time Auxiliary Relay activates when triggered.
Seconds = Output time in seconds (0-60)
Select Forced Entry Output Default: Output #3 Sets which output activates if the DOOR SENSE input opens before access is granted. This output is not timed.
Solid-state Output #3 On-time Default: 2 Seconds Sets the length of time Output #3 activates when triggered.
Press: 1 1 # Output #
Seconds = Output time in seconds (0-60), 99 = Toggle Mode
Output = Output to Activate (0-4) 1 = Main Relay 2 = Auxiliary Relay 3 = Output #3 4 = Output #4 0 = No Output
Solid-state Output #4 On-time Default: 2 Seconds Sets the length of time Output #4 activates when triggered.
Select Door Ajar Output Default: Output #4 Sets which output activates if the DOOR SENSE input stays open 60 seconds after access is granted. This output is not timed.
Seconds = Output time in seconds (0-60), 99 = Toggle Mode
Set Downlight On-Time Default: 2 Minutes Sets the time duration that the downlight remains on after a key press.
Output = Output to Activate (0-4) 1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output
Select Keypad Lockout Output Default: No Output Sets which output activates when the keypad is “locked out” after too many incorrect entry code attempts. The lockout time is 60 seconds.
0 = Always off, 1 = 1 minute, 2 = 2 minutes, 3 = 3 minutes, 4 = 4 minutes, 99 = Always on
Beep Sounds on Keystrokes Default: Yes Selects whether or not the keypad beeps as each key is pressed.
Output = Output to Activate (0-4) 1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output
Sound = 1 for Yes, = 0 for No
Select Keypad Active Output Default: No Output Sets which output activates when any keys are pressed. This output is timed. If toggle mode is selected for the output, the timer value defaults to 2 seconds.
Beep Sounds During Main Relay Default: No Selects whether or not the keypad beeps during Main Relay activation.
Press: 4 1 # Sound #
Output = Output to Activate (0-4) 1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output
Sound = 1 for Yes, = 0 for No
Select Alarm Shunt Output Default: No Output Sets which output activates during the time access is granted. (Use this output to shunt alarm contacts attached to the access door.) This output may be timed or toggled.
Output = Output to Activate (0-4) 1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output

Beep Sounds During Auxiliary Relay Default: No Selects whether or not the keypad beeps during Auxiliary Relay activation.
AK-21W OPERATION Keypad users request access by entering their code.
❑ Users of the AK-21W have up to 40 seconds to key in their
entry code. ❑ Up to eight seconds are allowed between each keystroke. ❑ All digits of the entry code must be entered. Example: If the
Sound = 1 for Yes, = 0 for No
code is 0042, the user must enter “0 0 4 2”. ❑ If the wrong key is pressed, pressing the * key will reset the
Beep Sounds During Output #3 Default: No Selects whether or not the keypad beeps during Output #3 activation.
keypad. The correct code can then be re-entered. ❑ After a correct code is entered, the red indicator will turn
Sound = 1 for Yes, = 0 for No
green and the programmed relay will activate for the programmed time. ❑ If the number of incorrect codes entered exceeds the
Beep Sounds During Output #4 Default: No Selects whether or not the keypad beeps during Output #4 activation.
keypad lockout count, the yellow indicator will light, indicating that the keypad is locked out. The lockout will remain for one minute. ❑ After a valid code has been entered, it will be unusable until
Sound = 1 for Yes, = 0 for No
the anti-passback time expires. SPECIFICATIONS
Keypad Lockout Count Default: 3 Tries Sets the number of incorrect entry code attempts allowed before the keypad “locks out”.
MECHANICAL Dimensions: 3.00” W x 5.00” H x 3.00” D ELECTRICAL Voltage: 12-24 Volts AC or DC Current: 30 mA typical, 150 mA maximum Outputs: Main Relay: Form “C” 5 Amps @ 28 Volts maximum Auxiliary Relay: Form “C” 1 Amp @ 28 Volts maximum Solid state outputs (Outputs #3 & #4): Short-to-common 100 mA @ 24 VDC maximum ENVIRONMENTAL Temperature: -22°F to 149°F (-30°C to 65°C) Humidity: 5% to 95% non-condensing LINEAR LIMITED WARRANTY This Linear product is warranted against defects in material and workmanship for twenty-four (24) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until Warranty Expiration Date as labeled on the product. This Linear LLC Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details. FCC NOTICE Changes or modifi cations not expressly described in this manual or approved by the manufacturer could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Attempts = Number of attempts before lockout (2-7)
Anti-passback Time Default: No Anti-passback Sets the length of time an entry code will not function after it is used.
Minutes = Time in Minutes (1-4), 0 = No Anti-passback RESETTING KEYPAD
the entire memory of the AK-21W and return all programmable options to the factory default values. ALL ENTRY CODES WILL BE ERASED. STEP 1 Disconnect power from the keypad. STEP 2 Press and hold down the * and # keys. STEP 3 Apply power to the keypad, continue holding the keys
down until the red indicator starts fl ashing. STEP 4 Release the keys. The red and yellow indicators will
remain lit until the process is complete, then the yellow indicator will go out.
Resetting the Master Code
STEP 1 Open the AK-21W case. STEP 2 Locate jumper JP2. This jumper is used to reset the
master code. STEP 3 With power applied to the keypad, remove jumper JP2.
The keypad will begin to beep, signaling that the code has been reset. STEP 4 Replace jumper JP2.
THE MASTER PROGRAMMING CODE IS NOW 123456.