Table of Contents 80 sections continuously upgraded accordingly. Therefore minor changes compared · This KVM switch incorporates a modular concept design which allows · computer via a web browser. The required optional IP access module · for dual console access. The local console port allows direct access · … ShowHide
continuously upgraded accordingly. Therefore minor changes comparedp.1This KVM switch incorporates a modular concept design which allowsp.1computer via a web browser. The required optional IP access modulep.1for dual console access. The local console port allows direct accessp.1The KVM Switch CAT-32 IP provides 32 Cat.5/6 KVM server portsp.1supporting both USB or PS/2 keyboard and mouse connections viap.1whilst a second console option permits remote access via a remotep.1The KVM Switch and especially the KVM over IP Module and itsp.1software are subject to technological progress. The products arep.1Switch. This option allows system administrators to access andp.1administer their servers and KVM switches from a remote officep.1The modular LINDY KVM Switch CAT-32 IPp.1Technological progressp.1About this manualp.1KVM Switch CAT-32 IPp.1with KVM over IP Modulep.1User Manual Englishp.1KVM Switch CAT-32 IP: LINDY No. 39632p.1KVM over IP Module: LINDY No. 39636p.1www.lindy.comp.11.3. KVM compatibility with other series KVM switchesp.31.2. CAT-32 with IP access modulep.3KVMp.31.1. Introductionp.31.6. Optional Cables and Accessoriesp.41.5. Package Contentsp.41.4. Product Featuresp.42.1. Hardware Installation Guidep.5Hardware Installationp.5Section 2p.53.1. KVM Switch Operationp.63.1.1. Password Securityp.63.1.2. Hot Plug Supportp.6KVM Switch Operationp.6Section 3p.63.3. On Screen Display Menu (OSD)p.7Further available direct hotkey commands:p.73.1.3. Computer / Port Selectionp.73.1.4. Illuminated front displayp.7IP Access Configuration &p.8Section 5p.8Operationp.8Intentionally left emptyp.8For future usep.8Section 4p.83.4. Troubleshootingp.8Initial Configuration via a Serial Consolep.95.1. Configurationp.9IP [192.168.1.22]:p.95.0.2 KVM over IP Access Module Installationp.95.0.1. KVM over IP Access Featuresp.9Authenticationp.105.2 CAT-32 IP Setup Toolp.10MAC Address Detectionp.10Single and Double Mouse Modep.11Recommended Mouse Settingsp.11Host System Mouse Settingsp.11Video Modesp.11MAC OS Xp.115.3. Keyboard, Mouse and Video Configurationp.11CAT-32 IP Keyboard Settingsp.11Remote Mouse Settingsp.11Login to the CAT-32 IPp.125.5. Logging Inp.12Important: We recommend you install the latest version of Sun’sp.12Java Virtual Machine which can be downloaded from thep.12following web site:p.12www.java.comp.125.4. Usagep.12Prerequisitesp.12HTTP/HTTPSp.12Remote Console Main Windowp.135.6. Navigationp.13Remote Console Control Barp.145.7.1. Remote Controlp.165.7. Menu Optionsp.16KVM Consolep.16Remote Console Status Linep.16Telnet Consolep.175.7.2 . Virtual Mediap.18
Page 1 of the Lindy 39632 user manual — KVM Switch CAT-32 IP: LINDY No. 39632
Page 1 · click to enlarge
Page 1
  • The third section describes the basic operation of the KVM switch via its OSD (On Screen Menu)

continuously upgraded accordingly. Therefore minor changes compared

This KVM switch incorporates a modular concept design which allows

KVM over IP module installed in a slot located in the back of the KVM

computer via a web browser. The required optional IP access module

  • The second section deals with installing and connecting the switch

for dual console access. The local console port allows direct access

can be simply installed into the back of the KVM Switch at any time.

The KVM Switch CAT-32 IP provides 32 Cat.5/6 KVM server ports

supporting both USB or PS/2 keyboard and mouse connections via

whilst a second console option permits remote access via a remote

  • The fifth section describes operation and access via remote IP
  • The first section is an introduction to the KVM Switch CAT-32

The KVM Switch and especially the KVM over IP Module and its

software are subject to technological progress. The products are

Switch. This option allows system administrators to access and

administer their servers and KVM switches from a remote office

The modular LINDY KVM Switch CAT-32 IP

dedicated USB or PS/2 Cat.5 Computer Modules.

to the descriptions in this manual may be found.

This manual is divided into five sections.

  • Section 4 – left empty for future use

Technological progress

About this manual

KVM Switch CAT-32 IP

with KVM over IP Module

Lindy 39632 — Technological progress diagram (page 1)
Fig. 1 · Technological progress

User Manual English

© LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - FIRST EDITION (JAN 2010)

KVM Switch CAT-32 IP: LINDY No. 39632

KVM over IP Module: LINDY No. 39636

www.lindy.com

For Commercial Use Only

with FCC Standards · Tested to comply

Page 2 of the Lindy 39632 user manual — continuously upgraded accordingly. Therefore minor changes compared
Page 2 · click to enlarge
Page 2
Page 2 of the Lindy 39632 user manual — continuously upgraded accordingly. Therefore minor changes compared
Page 3 of the Lindy 39632 user manual — 1.1. Introduction
Page 3 · click to enlarge
Page 3

Section 1 Introducing the CAT-32 IP

KVM over IP technology allows a simple web browser interface to be used to access the switch

and the connected computers via a local area network (LAN) or, when connected to a wide area

mass storage support; a USB connection from the switch to a connected computer allows virtual

Doing so any files, folders or local drives at the remote user can be configured as a local drive

cascaded installation. To prevent any hotkey conflicts, please ensure that the KVM hotkeys of

because the software runs on its embedded processors only, so there’s no interference with

computer operation, or impact on network performance. The IP module also features remote

The KVM Switch CAT-32 is compatible with most other brands of KVM switches using a port

the other KVM switches used are not the same as those used on the KVM Switch CAT-32 IP.

The CAT-32 with IP module provides a non-intrusive solution for remote access and control

1.3. KVM compatibility with other series KVM switches

network (WAN), allows access to the switch and the connected computers from almost

storage to be set up on the computer as a virtual drive accessed from the client.

The KVM hotkeys of the KVM Switch CAT-32 IP can be configured via the OSD.

Remote & local control of multiple computers

Lindy 39632 — 1.3. KVM compatibility with other series KVM switches diagram (page 3)
Fig. 2 · 1.3. KVM compatibility with other series KVM switche…

at the remote computer allowing for driver installation and updates etc.

1.2. CAT-32 with IP access module

KVM

anywhere in the world.

Lindy 39632 — KVM diagram (page 3)
Fig. 3

Section 1 Introducing the CAT-32 IP

Using the LINDY KVM Switch CAT-32 IP a system administrator can access and control several

The LINDY KVM Switch CAT-32 allows direct access to up to 32 computers using a single KVM

Access Module into a slot located in the back of the KVM switch. With this module installed the

administrator can access any of the computers connected to the KVM Switch from any remote

number of computers multiple switches can be used. They can be either equipped with a KVM

(Keyboard, Video, and Mouse) either from a local or remote console. To administrate a larger

A dedicated daisy chain port allows a total number of 8 KVM Switches to be connected (daisy

chained) together to control up to 256 computers. Using this daisy chain port method ensures

The KVM Switch CAT-32 IP has a single user password protection with auto logout security.

Thank you for purchasing this LINDY KVM Switch. Please read this manual carefully to fully

In addition the KVM Switch CAT-32 allows you to install an optional KVM over IP Remote

over IP module each or they can easily be daisy chained with an IP module located in the

that none of the computer ports are lost due to cascading. Using IP modules in each KVM

The security features for the KVM over IP user are based on SSL and additionally KVM

computers from one compact and high density KVM control center with 32 server ports

Switch allows users to access even more than 256 computers and provides individual

The CAT-32 KVM Switch supports two methods of switching between the connected

simultaneous access to every KVM switch with an IP module and by several users.

computers: by using keyboard hotkeys or via an OSD (On Screen Display).

computer on a local LAN or via the Internet using a web browser.

understand the functions and features that the switch offers.

encrypted connections with a further level of password login.

occupying only 1U height within a 19” rack.

1.1. Introduction

master KVM switch only.

Show 5 more labels / short text on this page
Local Console · Multiple Servers · Switch · IP Network · Remote Access
Page 4 of the Lindy 39632 user manual — 1.4. Product Features
Page 4 · click to enlarge
Page 4

Section 1 Introducing the CAT-32 IP

disconnected and the power supply is unplugged. Open the slot on the back of the KVM Switch

To connect each individual computer to the switch, Cat.5/6 computer modules are required. For

A short Daisy Chain Cable is included to cascade KVM switches with each other. Longer cables

(To install it into the KVM Switch CAT-32 ensure all connected computers are switched off or

The local monitor, PS/2 mouse and PS/2 keyboard is connected using their standard cables.

Switch to the computer modules. These cables are available from LINDY in several different

A Cat.5e or 6 UTP cable of appropriate length (max. 100m) is required to connect the KVM

The remote access KVM over IP module, LINDY No. 39636, can be installed at any time.

  • For PS/2 computers: Cat.5/6 Computer module PS/2 & VGA, LINDY No. 39633
  • For USB computers: Cat.5/6 Computer module USB & VGA, LINDY No. 39634

colors and lengths from 0.3m up to 100m. We don’t recommend using shielded FTP/STP

(4) Printed Quick Start Guides (English, French, German, Italian)

To reach even longer distances several 2m cables can be chained together.

USB or PS/2 computers different modules have to be used as listed below:

(6) User manuals (English, French, German, Italian)

No. 39636, (1) KVM over IP Module for KVM Switch CAT-32 IP

0.5m 1m 2m 3m 5m 7.5m 10m 15m 20m 30m 45961 45962 45963 45964 45965 45966 45967 45968 45969 45970

0.5m 1m 2m 3m 5m 7.5m 10m 15m 20m 30m 45771 45772 45773 45774 45775 45776 45777 45778 45779 45780

are available from LINDY: No. 39637 (1m) and No.39638 (2m).

1.6. Optional Cables and Accessories

(3) CD with Utilities & Manual (English)

40m 50m 60m 70m 80m 90m 100m 45971 45972 44733 45974 44735 44736 45977

(2) Firmware upgrade cable

(2) USB cable type A/Mini-B

cables. Please find a small overview below:

No. 39632, (1) KVM Switch CAT-32

1.5. Package Contents

(5) 19" Rackmount Kit

(3) Daisy Chain cable

and slide the module into the slot.)

UTP Cat.5e

UTP Cat.6

Section 1 Introducing the CAT-32 IP

Auto Scan Mode with an adjustable scan time from 5~104 seconds for monitoring computers

High Quality Video – Supports display resolutions of up to 1920 x 1200 at the local console

Dual console operation optionLocal console connected by PS/2 and VGA plus a remote

Separate built-in daisy chain port prevents the loss of any computer port when cascading

32x RJ45 ports for UTP cables to connect to the servers with up to 100m distance each

Hot Plug Support allows computers to be added or removed for maintenance without

No Software Required - easy computer selection via the On Screen Display Menu or

Supports USB as well as PS/2 computers using the appropriate Computer Modules

Supports up to 1280 x 1024 at the IP console, 1600 x 1200 in virtual desktop mode

Password log in protection for access to the KVM Switch, auto log out option

Keyboard status automatically restored when switching between computers

Each computer can be individually named in the On Screen Display Menu

32 UTP Cat.5/6 server ports in a narrow 1U, 19” rack mount design

SSL security and additional password protection for IP access users

2 Digit LED display indicates the cascaded KVM Switch number

Compatible with all commonly used operating systems

Front panel LED indicators for easy status monitoring

powering down the KVM switch or the computers

access slot for optional KVM over IP module

1.4. Product Features

(4) Power Adapter · Daisy Chain Cable · Keyboard Hot Keys

Page 5 of the Lindy 39632 user manual — Hardware Installation
Page 5 · click to enlarge
Page 5

Section 2 Hardware Installation

KVM switch to the Daisy Chain IN port of the second slave KVM switch. Repeat this step up to

You may also wish to attach one of the information labels supplied with the KVM over IP

module to the back (or the front) of the KVM Switch so that you can easily locate the IP

standard daisy chain KVM cable as mentioned above. Connect it to the Daisy Chain OUT port

To set up and configure the KVM over IP remote access modules please refer to section

If you want to install the KVM Switch in a 19” server rack please attach the enclosed 19” rack

module slot before you connect the servers and the power supply to the KVM Switch.

In addition to the computers/servers to be connected you will need a PS/2 keyboard, monitor

To connect an additional slave KVM Switch to the MASTER (or previous) KVM switch use a

of the MASTER KVM switch and to the Daisy Chain IN port of the first slave KVM switch. To

2. Connect the keyboard, monitor and mouse directly to the ports of the LINDY KVM

Before you start please verify that all parts are included according to the package contents

Please prepare the required amount of KVM Computer Access Modules and UTP cables to

If you intend to install the optional KVM over IP module then please install it into the

You can integrate up to 8 KVM Switches in one KVM daisy chained installation with up to a

connect the second slave KVM switch connect the Daisy Chain OUT port of the first slave

3. Now connect the servers and computers to the ports labelled 1 to 32 using UTP

You may also refer to the printed Quick Start Guide supplied with the KVM over IP

cable of appropriate length and an appropriate Computer Access Module.

4. Attach the power supply to the KVM Switch. Switch on your monitor.

a maximum of 8 KVM switches with a maximum of 256 servers.

Cascading / Daisy chaining of multiple KVM Switches

1. Switch off all the computers to be attached.

2.1. Hardware Installation Guide

Switch labelled Local Console.

mount brackets using the screws provided.

and PS/2 mouse to use as a local console.

maximum of 256 attached computers.

connect to your computers/servers.

modules MAC address.

4 of this user manual.

listed previously.

module.

Hardware Installation

Section 2

Page 6 of the Lindy 39632 user manual — KVM Switch Operation
Page 6 · click to enlarge
Page 6

required to turn off the computer. Simply hot-plug the PS/2 computer module to the computer.

Section 3 KVM Switch Operation

If a computer is already running and its PS/2 interface has already been initialized, it is not

Always connect the PS/2 mouse port first to allow the correct initialization sequence! If the PS/2

ports of the computer haven't been initialized during boot up it may however be necessary to

turn off the computer before connecting the PS/2 computer module so the OS can initialize the

The USB and VGA interface is hot pluggable on most OS and computer systems. Therefore you

may connect and disconnect USB computer modules at any time. Connect the computer

modules to the KVM Switch using UTP Cat.5e/6 cables of appropriate length. In most cases

standard patch cable UTP Cat.5e or 6 can be used without any problems. For best video results

at very large distances and high resolutions UTP Cat.6 solid core cable may be used to improve

video quality and distance. Shielded FTP/STP is not recommended. After the computers are

Please NoteYour monitor will only display one computer signal at any one time. All

The KVM Switch CAT-32 IP has a single user password protection with auto logout security.

The additional security features for the KVM over IP user are based on SSL and additionally

When the computer connected to the currently selected port is not switched on,

The KVM Switch supports a “Hot Plug” function for easy addition or removal of computers.

Please noteSome Operating Systems including certain Unix versions may be unable to

keyboard and mouse commands are sent to this computer as shown on the monitor.

KVM encrypted connections with a further level of password login. Details can be found in

support the “Hot Plugging” function. If you “Hot Plug” when using this kind of O.S., it may

connected and powered up you can access them from the KVM Switch CAT-32.

cause unpredictable operation and may even shut down the computer.

or is in sleep mode, the monitor will not display any signal.

3.1. KVM Switch Operation

3.1.1. Password Security

section 5, KVM over IP module.

3.1.2. Hot Plug Support

PS/2 ports during boot up.

KVM Switch Operation

Section 3

PS/2 computer modules · USB computer modules

Page 7 of the Lindy 39632 user manual — 3.1.4. Illuminated front display
Page 7 · click to enlarge
Page 7
Lindy 39632 — 3.3. On Screen Display Menu (OSD) diagram (page 7)
Fig. 4 · 3.3. On Screen Display Menu (OSD)
Lindy 39632 — 3.3. On Screen Display Menu (OSD) diagram (page 7)
Fig. 5 · 3.3. On Screen Display Menu (OSD)
Lindy 39632 — 3.3. On Screen Display Menu (OSD) diagram (page 7)
Fig. 6 · 3.3. On Screen Display Menu (OSD)

Section 3 KVM Switch Operation

the attached computers, and offers advanced administration and full KVM Switch control to the

The On Screen Display menu provides a lot of information about the switch configuration and

Video Setting Main Menu

F1 Setup OSD Menu

3.3. On Screen Display Menu (OSD)

shadows followed by gain for the brightness. It may

Select computer/portuse Up/Down Arrow key to

navigate, Page Up/Page Down to scroll page, hit

F2: Save - Save all modifications you have made.

AutoScan periodSpecify the delay time for auto

remote console On/Off. If the remote console is in

under the OSD title bar, Remote control disabled

Allows you to adjust video settings individually for

Go to Main/Video setting, and then begin to adjust

Start with equalization to adjust the sharpness and

F1Setup - rotate through Main/ Video Setting/
Auto logoutspecify the timeout before an auto-
Hotkeyspecify the hotkey preceding sequence
PasswordEnable/Disable password protection

OFF state, a message will remind you appearing

the video parameters such as gain/equalization.

be necessary to try several different settings and

combinations to achieve the best display. Always

Activate the OSD by the hotkey sequence:

Edit computer namejust hit Insert to edit and
Enable /Disable Remote ConsoleToggle the

When pressing F2, you will see the message--

OSD Timeoutspecify timeout for OSD menu

(SCROLL LOCK, CAPS, F12 or NUM LOCK)

Equspecify level of equalization. (00 ~ 50)

Scroll Lock + Scroll Lock + space bar

remaining on screen (00~99 sec, +5 sec)

logout (00~99 min, +1 min) is performed

"Saving parameters" for confirmation.

Title barSpecify the title bar position

Always press F2 to save any changes!

Gainspecify level of gain. (00 ~ 50)

Setup/ Status OSD menu pages

press F2 to save any changes!

scan (00~99 sec, +5 sec)

Enter to confirm.

Enter to select.

every port:

user.

CommandAction ↑ (Cursor up) / ↓ (Cursor down)Select next higher/lower port Page Up / Page DownSelect next higher/lower bank/KVM switch H + { Scroll / Num / Caps / ESC / F12 }Change primary hotkey 0101 0832Bank + port number direct selection TOSD port info screen on/off ZRemote console on/disabled SStart Autoscan

Section 3 KVM Switch Operation

Page Up / Page Down Select next higher/lower bank/KVM switch

0101 0832 Bank + port number direct selection

switch computer ports directly or change the KVM Switch CAT-32 settings etc.

↑ (Cursor up) / ↓ (Cursor down) Select next higher/lower port

Z Remote console on/disabled

keyboard/mouse commands are sent to the computer attached to this port.

navigate through the OSD and select functions by pressing the Return key.

T OSD port info screen on/off

H + { Scroll / Num / Caps / ESC / F12 } Change primary hotkey

Press the following key combination to enter the OSD menu:

Further available direct hotkey commands:

On screen display menu selection

3.1.3. Computer / Port Selection

Keyboard hotkey selection

3.1.4. Illuminated front display

Show 12 more labels / short text on this page
Main OSD Menu · Video setting Menu · Setup OSD Menu · Main OSD Menu · (Left/Right/Disable) · S Start Autoscan · Command Action · Space bar Scroll · + + · Within 2 seconds · Lock Scroll · Lock
Page 8 of the Lindy 39632 user manual — 3.4. Troubleshooting
Page 8 · click to enlarge
Page 8

IP Access Configuration &

Section 5

Operation

Intentionally left empty

For future use

Section 4

Lindy 39632 — For future use diagram (page 8)
Fig. 7 · For future use
Lindy 39632 — For future use diagram (page 8)
Fig. 8 · For future use

console keyboard and mouse has happened. If this doesn't work, unplug the computer modules

A2. Please check if the computer you want to access is in Standby or power save mode with the

Section 3 KVM Switch Operation

Q1. My keyboard and/or mouse are locked up. What can I do for troubleshooting without

PS/2 or USB connections from the computer for few seconds and plug it in again - alternatively

connection first, then the keyboard connection. This should bring back the computer module if

only re-initialization is required. If any of the above does not help then you may have to reboot

A1. First, unplug the console keyboard and mouse for a few seconds and plug them back in.

Use the supplied Firmware update cable to connect between the Daisy Chain In port of the

This will re-initialize the console keyboard and mouse, in case an initialization failure of the

plug the USB connector into to a different USB port. If it is PS2, always connect the mouse

The contact information for the LINDY technical support teams can be found on the LINDY

Computer Module Status Submenu

Before calling technical support, please try the following steps for easy troubleshooting.

monitor switched off. If so please wake up the computer in the usual way.

the computer for a complete reset of the computer keyboard and mouse.

KVM switch and the DB9 RS-232 port on your computer.

Use this page to check the firmware version of

selected KVM Switch (i.e. 120208 shown here

connected to this KVM Switch) upgrade mode.

Enter to access the status pages of the Cat.5

process a download bar will appear indicating

More detailed information is provided with the

version, KVM Switch PCB model and max.

number of ports. Select one bank and press

computer modules, just select the module to

be upgraded and press Enter to confirm the

the progress of the upgrade. In addition you

can alternatively press F4 to toggle between

rebooting the computer and/or KVM?

This status page shows information for all

computer modules connected to that KVM

Computer Module Status Submenu

the Cat.5 Computer Modules attached to a

is the FW version of the KVM Switch), and

daisy chained KVM SwitchesFirmware

automatic upgrade. During the upgrade

perform manual FW upgrades. To do a

manual FW upgrade of individual Cat.5

manual and auto (for all Cat.5 modules

3.4. Troubleshooting

Q2. My monitor stays dark.

website for each country.

Firmware upgrade files.

Switch.

Status Menu · Firmware Update · Status Menu

Page 9 of the Lindy 39632 user manual — 5.0.1. KVM over IP Access Features
Page 9 · click to enlarge
Page 9
Lindy 39632 — Initial Configuration via a Serial Console diagram (page 9)
Fig. 9 · Initial Configuration via a Serial Console

If this initial configuration does not meet your requirements, the following section describes the

By default, the CAT-32 IP will try to contact a DHCP server in the subnet to which it is physically

connected. If a DHCP server is found, it will provide a valid IP address, gateway address and

subnet mask. If a DHCP server is not available then you will need to assign a fixed IP

assignment to the MAC address of the IP Access Module. You can find the MAC address

Before you connect the device to your local subnet, be sure to complete the corresponding

configuration using the setup tool supplied on the CD ROM. Follow the procedure described on

When configuring with a serial terminal, reset the CAT-32 IP and immediately press the ESC

key. You will see some device information and a “=>” prompt. Type config and press the Enter

As you proceed, the following questions will appear on the screen. To accept the default values

Bits/second 115200 Data bits 8 Parity No

ParameterValue IP auto configurationDHCP IP-Address- Net-mask255.255.255.0 Default-Gatewaynone

Stop bits 1 Flow Control None

configuration that is necessary to access the CAT-32 IP for the first time.

details on the printed label on the underside of the IP Access module.

key. Wait a few seconds for the configuration information to appear.

(shown in square brackets below) press the Enter key.

The CAT-32 IP has a serial line interface (host side)

for connecting a serial terminal. This connector is

compliant with the RS232 serial line standard. The

serial line has to be configured with the parameters

Initial Configuration via a Serial Console

IP auto configuration (non/dhcp/bootp) [dhcp]:

Initial Configuration via a DHCP Server

Gateway (0.0.0.0 for none) [0.0.0.0]:

5.1. Configuration

the next page (Section 5.2)

Net mask [255.255.255.0]:

given in this table:

IP [192.168.1.22]:

ParameterValue Bits/second115200 Data bits8 ParityNo Stop bits1 Flow ControlNone

The KVM over IP Access module can be accessed via a simple web browser and via dedicated

control. Also the available screen resolution, colour depth and refresh rates will also be affected.

Ensure the connection you are using provides adequate bandwidth, some adjustment of screen

For the remainder of this manual the CAT-32 KVM switch with installed KVM

connected to your network and provides full KVM access including BIOS level access to all the

degree of time delay will occur due to limiting factors such as available bandwidth and network

are switched off and the power supply is unplugged. Proceed to unscrew and remove the small

converts all keyboard video and mouse signals and sends them as TCP/IP signals over your

amount of CPU processing time. Transporting large amounts of data over TCP/IP requires a

A connection which exhibits limited bandwidth will result in slower mouse reaction and cursor

Before you install the IP Access module into the KVM switch ensure all connected computers

metal cover on rear of the KVM switch. Carefully slide the module into the slot and secure in

You may now proceed to power up all connected equipment and check for correct operation.

Please note that KVM over IP does not operate in a “real time” environment and that some

The IP access module provides remote KVM over IP access to the KVM switch CAT-32. It

software tools included with the product. It uses secure encrypted sessions and password

LAN/WAN connection. The KVM switch CAT-32 IP may be accessed from any computer

Please note that the conversion of video, mouse and keyboard signals requires a certain

resolution, colour depth and mouse cursor control may have to be made for satisfactory

high bandwidth connection. Limited bandwidth may restrict or limit the possible screen

resolutions and colour depths which can be transmitted over your LAN / WAN.

5.0.2 KVM over IP Access Module Installation

over IP Module will be referred to as CAT-32 IP.

5.0.1. KVM over IP Access Features

place with the screw previously removed.

authentication protocols.

connected computers.

operation.

traffic.

Parameter Value

Page 10 of the Lindy 39632 user manual — MAC Address Detection
Page 10 · click to enlarge
Page 10

To adjust the authentication settings, enter your login as a super user and change your

Enter the login name of the super user. The initial value is "super". All of the characters are

Enter the current password for the super user. This initial value is "pass". All of the characters

To close the window and accept the changes, press the OK button, otherwise press the Cancel

With this option, you can specify whether the CAT-32 IP should obtain its network settings from

a DHCP or BOOTP server. From the drop down list select either DHCP or BOOTP. If you

select NONE, the IP auto configuration is disabled and you should manually input the following

The IP address of the default router for the connected IP subnet. If you do not have a default

Re-type the new password for the super user.

Enter the new password for the super user.

The net mask of the connected IP subnet.

The IP address the CAT-32 IP uses.

New super user password

router, enter 0.0.0.0.

Authentication

network settings:

are lower case.

password.

lower case.

button.

Connect the CAT-32 IP to your computer either via a local network, or via USB. If you use a

USB connection Windows will detect the CAT-32 IP as a ‘Removable Disk’ and an appropriate

On the upper left corner, the MAC address of the CAT-32 IP is displayed. To re-detect the MAC

address, press the Refresh Devices button. The displayed MAC address should correspond to

On the lower right corner of the window, there are two buttons: Query Device and Setup

Device. Press the Query Device button to display the preconfigured values of the network

configuration. The values are displayed in the text fields located above. If necessary, adjust the

network settings to your needs. To save the changes enter a user login and a password (see

Lindy 39632 — Authentication diagram (page 10)
Fig. 10 · Authentication

the printed address shown on the label on the base of the IP module.

Authentication, below) and then press the Setup Device button.

Start the setup tool from the CD ROM.

5.2 CAT-32 IP Setup Tool

A window opens as shown below:

MAC Address Detection

drive letter will be assigned.

Show 7 more labels / short text on this page
New password (confirm) · IP Auto Configuration · Super user password · Gateway address · Super user login · IP address · Net mask
Page 11 of the Lindy 39632 user manual — Remote Mouse Settings
Page 11 · click to enlarge
Page 11

There are mouse drivers which influence the synchronization process and lead to

desynchronized mouse pointers. If this happens, make sure you do not use a special vendor-

If the Active Desktop feature of Microsoft Windows is enabled, do not use a plain background.

Instead, use some kind of wallpaper. Alternatively, you could also disable the Active Desktop

Navigate your mouse pointer into the upper left corner of the applet screen and move it back

and forth slightly. In this way the mouse will be resynchronized. If re-synchronizing fails, disable

In general, we recommend the use of a USB mouse. Choose USB without Mouse Sync. For a

For XP, Vista, disable the option called enhance pointer precision or similar in the Control

Adjust the mouse settings either via xset m 1 or use the CDE Control Panel to set the mouse to

The CAT-32 IP switch recognizes a limited number of common video modes. When running

X11 on the host system, please do not use any custom mode lines with special video modes. If

you do, the CAT-32 IP switch may not be able to detect them. We recommend using any of the

pointers are visible and need to be synchronized. The CAT-32 IP also features another mode -

Single Mouse Mode, where only the remote mouse pointer is visible. Activate this mode in the

and the remote one can be controlled directly. To leave this mode, use the hotkey combination

The information above applies to Double Mouse Mode, where both remote and local mouse

open Remote Console and click into the window area. The local mouse pointer will be hidden

1:1, no acceleration. As an alternative you may also use the Single Mouse Mode.

The host's operating system obtains various settings from the mouse driver.

If using Windows XP, disable the enhance pointer precision setting.

For the different operating systems we can give the following advice...

MS Windows 2000/2003 (Professional and Server), XP, Vista,

[ALT] + [F12] to free the captured local mouse pointer.

We recommend using the Single Mouse Mode.

mouse acceleration and repeat the procedure.

specific mouse driver on your host system.

PS/2 mouse choose Auto Mouse Speed.

Single and Double Mouse Mode

Recommended Mouse Settings

standard VESA video modes instead.

Host System Mouse Settings

Windows 2000 and higher!

Windows XP Mouse Settings

Video Modes

completely.

MAC OS X

Panel.

Between the CAT-32 IP and the host, there are two interfaces available for transmitting

keyboard and mouse dataUSB and PS/2. The correct operation of the remote mouse depends

The CAT-32 IP settings for the host's keyboard type have to be correct in order to make the

remote keyboard work properly. The settings can be checked using the CAT-32 IP front-end,

A common problem with KVM devices is the synchronization between the local and remote

mouse cursors. The CAT-32 IP addresses this problem with an intelligent synchronization

algorithm. There are two mouse modes available on the CAT-32 IP: Auto mouse speed and

The automatic mouse speed mode tries to detect the speed and acceleration settings of the

host system automatically. Speed detection is performed during mouse synchronization. If the

mouse does not move correctly, there are two ways to re-synchronize the local and remote

Fast SyncFast synchronization is used to correct a temporary, but fixed skew. Choose this

option using the Remote Console options menu or by pressing the mouse synchronization

Intelligent SyncIf the fast sync does not work correctly or the mouse settings have been

changed on the host system, you can use the intelligent resynchronization option. This method

Intelligent synchronization requires a correctly adjusted picture. Use the auto adjustment

function or manual correction in the Video Settings panel to setup the picture. The Sync mouse

button on top of the Remote Console can behave differently, depending on the current

state of mouse synchronization. Usually pressing this button leads to a fast sync, except in

This mode just translates the mouse movements from the Remote Console in a way that one

pixel move will lead to ‘n’ pixel moves on the remote system. This parameter ‘n’ is adjustable.

However, it should be noted that this works only when mouse acceleration is turned off on the

can be accessed from the Mouse Handling sub menu of the Remote Console Option menu.

Intelligent Sync from the Mouse Handling sub menu of the Remote Console Option menu.

on several settings which will be discussed in the following subsections and section 5.7.4.

pointer, click the Auto Adjust Button once. If the mouse is still not synchronized select

please see section 5.7.4 for details of how to make changes to the keyboard settings.

5.3. Keyboard, Mouse and Video Configuration

situations where the KVM port or the video mode was recently changed.

CAT-32 IP Keyboard Settings

hotkey sequence - [ALT] + [F12]

Remote Mouse Settings

Fixed mouse speed.

remote system.

mouse:

Show 5 more labels / short text on this page
Special Mouse Driver · Active Desktop · SUN Solaris · Auto mouse speed · Fixed mouse speed
Page 12 of the Lindy 39632 user manual — Prerequisites
Page 12 · click to enlarge
Page 12

Launch your web browser. Direct it to the address of your CAT-32 IP which you configured

during the installation process. The address used might be a plain IP address or a host and

ExampleType the following in the address line of your browser when establishing an

The CAT-32 IP has a built-in super user account that has all the permissions enabled to

Please make sure you change the super user password immediately after you have installed

and accessed your CAT-32 IP for the first time. Not changing the password for the super user is

a severe security risk and could result in unauthorized access to the switch and to the host

The KVM over IP Module, its software and firmware are subject to technological progress

the descriptions in this manual may be found, especially for the design of the screens and

and are being continuously upgraded accordingly. Therefore minor changes compared to

domain name if you have given your CAT-32 IP switch a symbolic name in the DNS.

Please note: Your web browser has to accept cookies, or else login is not possible.

Lindy 39632 — Login to the CAT-32 IP diagram (page 12)
Fig. 11 · Login to the CAT-32 IP

Login name super (factory default)

Password pass (factory default)

This will lead you to the CAT-32 IP login page as shown below:

When using a secure connection, type in:

https://<IP address of CAT-32 IP>

administrate your CAT-32 IP switch:

http://<IP address of CAT-32 IP>

system(s) to which it is connected.

Login to the CAT-32 IP

5.5. Logging In

unsecured connection:

menus.

Login namesuper (factory default) Passwordpass (factory default)

The CAT-32 IP features an embedded operating system offering a variety of standardized

interfaces. This section will describe these interfaces, and the way to use them in a more

A standard Telnet client can be used to access an arbitrary device connected to the CAT-32

Full access is provided by the embedded web server. The CAT-32 IP switch environment can

be entirely managed using a standard web browser. You can access the CAT-32 IP using the

insecure HTTP protocol, or using the encrypted HTTPS protocol. Whenever possible, use

The primary interface of the CAT-32 IP is the HTTP interface. This is covered extensively in this

In order to use the Remote Console window of your managed host system, the browser must

feature Java Runtime Environment version 1.1 or higher support. If the browser has no Java

support (such as on a small handheld device), you can still maintain your remote host system

In order to access the remote host system using a securely encrypted connection, you need a

browser that supports the HTTPS protocol. Strong security is only assured by using a key

length of at least 128 Bit. Some older browsers do not have a strong 128 Bit encryption

Important: We recommend you install the latest version of Sun’s

For a non-secure connection to the CAT-32 IP, we recommend the following browsers:

Java Virtual Machine which can be downloaded from the

detailed manner. The interfaces are accessed using the TCP/IP protocol family.

section. Other interfaces are addressed in the relevant subsections.

using the administration forms displayed by the browser itself.

following web site:

www.java.com

Microsoft Internet Explorer version 6.0 or higher

Netscape Navigator 7.0 or Mozilla 1.6

The following interfaces are supported:

IP’s serial port via a terminal.

5.4. Usage

Prerequisites

HTTP/HTTPS

algorithm.

HTTPS.

Technological progress · Telnet

Page 13 of the Lindy 39632 user manual — 5.6. Navigation
Page 13 · click to enlarge
Page 13

The Remote Console is the redirected screen, keyboard and mouse of the remote host system

that the CAT-32 IP switch controls. Selecting this button opens the Remote Console Main

The Remote Console window is a Java Applet that establishes its own TCP connection to the

CAT-32 IP. The protocol that runs over this connection is neither HTTP nor HTTPS, but RFB

(Remote Frame Buffer Protocol). RFB needs to establish a connection to port number 443. Your

local network environment has to allow this connection to be made, i.e. your firewall and, if you

have a private internal network, your NAT (Network Address Translation) settings have to be

If the CAT-32 IP is connected to your local network environment and your connection to the

Internet is available using a proxy server only, without NAT being configured, the Remote

Console is very unlikely to be able to establish a connection. This is because today's web

If you experience problems, please consult your network administrator in order to provide an

Starting the Remote Console opens an additional window. It displays the screen content of the

currently selected computer connected to the CAT-32 IP. The Remote Console will behave in

exactly the same way as if you were using the local console. You can use the CAT-32 IP

keyboard hotkeys to switch between computers, activate the OSD etc., as well as control the

currently selected computer. However, be aware that the host system will react to keyboard and

Lindy 39632 — Remote Console Main Window diagram (page 13)
Fig. 12 · Remote Console Main Window

proxies are not capable of relaying the RFB protocol.

Remote Console Main Window

mouse actions with a slight delay.

appropriate network environment.

configured accordingly.

Window.

Once logged into the CAT-32 IP successfully, the main page appears. This page consists of

three parts; each of them contains specific information. The buttons in the upper area allow you

to navigate within the front end. The lower left area contains a navigation bar and allows you to

switch between the different sections of the CAT-32 IP. Within the main area, task-specific

This link logs out the current user and presents a new login screen. Please note that an

automatic logout will be performed if there is no activity for half an hour. Clicking one of the links

Lindy 39632 — Remote Console Main Window diagram (page 13)
Fig. 13 · Remote Console Main Window

Return to the main page of the CAT-32 IP

Access the Remote Console

Logout from the CAT-32 IP

will bring you back to the login screen.

information is displayed.

5.6. Navigation

Page 14 of the Lindy 39632 user manual — Remote Console Control Bar
Page 14 · click to enlarge
Page 14

Toggles the ‘Monitor only’ filter on or off. If the filter is switched on, no remote console

If a user has the appropriate permission, he can force the Remote Consoles of all other users to

close. No one can open the Remote Console at the same time again until this user disables the

Allows you to scale down the Remote Console. You can still use both mouse and keyboard;

The submenu for mouse handling offers two options for synchronizing the local and the remote

Offers a list of different cursor shapes to choose from for the local mouse pointer. The selected

shape will be saved for the current user and activated the next time this user opens the Remote

Console. The number of available shapes depends on the Java Virtual Machine; a version of

Opens a panel for changing the CAT-32 IP video settings. The CAT-32 IP features two different

The Noise Filter option defines how the CAT-32 IP reacts to small changes in the video input

signal. A large filter setting needs less network traffic and leads to a faster video display, but

small changes in some display regions may not be recognized immediately. A small filter

displays all changes instantly but may lead to a constant amount of network traffic even if

display content is not really changing (depending on the quality of the video input signal). All in

adjusted picture. Use the auto adjustment function or the manual correction in

Use this option if the fast sync does not work or the mouse settings have

A change in the access mode is also visible in the status line indicated by this icon.

Opens the Options menu. A short description of the each of the options follows:

The fast synchronization is used to correct a temporary, but fixed skew.

however the scaling algorithm will not preserve all display details.

Video Settings in the KVM section in the front end menu:

all the default setting should be suitable for most situations.

the Video Settings panel to setup the picture.

dialogs, which influence the video settings:

been changed on the host system

interaction is possible but monitoring is.

1.2 or higher offers the full list.

exclusive access, or logs off.

mouse pointer.

you use a German administration system and your host system uses a US English keyboard

layout for instance, some special keys on the German keyboard will not work as expected.

Instead, the keys will result in their US English counterpart. You can circumvent such problems

The Remote Console window always tries to show the remote screen with its optimal size. That

means it will adapt its size to the size of the remote screen initially and after the screen

resolution of the remote screen has been changed. However, you can always resize the

The upper part of the Remote Console window contains a control bar. Using its elements you

can see the state of the Remote Console and influence the local Remote Console settings. A

If the video display is poor quality or distorted in some way, click this button and wait a few

Activates the mouse synchronization process. Choose this option in order to synchronize the

local AND remote mouse cursors. This is especially necessary when using accelerated mouse

Switches between the Single Mouse Mode (where only the remote mouse pointer is visible) and

the Double Mouse Mode (where remote and local mouse pointers are visible) Single mouse

Lindy 39632 — Remote Console Control Bar diagram (page 14)
Fig. 14 · Remote Console Control Bar
Lindy 39632 — Remote Console Control Bar diagram (page 14)
Fig. 15 · Remote Console Control Bar

settings on the host system. In general, there is no need to change mouse settings on the host.

by adjusting the keyboard of your remote system to the same mapping as your local one.

seconds while the CAT-32 IP tries to adjust itself for the best possible video quality.

Sends the ‘Control Alt Delete’ key combination to the remote system

Remote Console window in your local window system as usual.

mode is only available if using SUN JVM 1.3 or higher.

mouse control and access the menus etc.

Remote Console Control Bar

description for each control follows.

Show 13 more labels / short text on this page
Intelligent Sync · Options · Exclusive Access · Mouse Handling · Fast Sync · Video Settings · Monitor Only · Local Cursor · Scaling · Single/Double mouse mode · Ctrl+Alt+Delete · Sync mouse · Auto Adjust button
Page 15 of the Lindy 39632 user manual — Remote Console Control Bar
Page 15 · click to enlarge
Page 15

Pops up the Soft-Keyboard. The Soft-Keyboard is necessary in case your host system runs a

Used to change the language mapping of your browser running the Remote Console Applet.

Normally, the applet determines the correct value automatically. However, depending on your

particular KVM and your browser settings this is not always possible. A typical example is a

German localized system that uses a US-English keyboard mapping. In this case you must

Opens a list of previously defined hotkeys. Choose one entry; the command will be sent to the

Lindy 39632 — Remote Console Control Bar diagram (page 15)
Fig. 16 · Remote Console Control Bar

completely different language and country mapping than your administration machine.

Lindy 39632 — Remote Console Control Bar diagram (page 15)
Fig. 17 · Remote Console Control Bar

Used for choosing the language and country mapping of the Soft-Keyboard.

manually change the local keyboard setting to the correct language.

A confirmation dialog can be added that will be

displayed before sending the selected command

to the remote host. Select OK to perform the

Opens up the sub-menu for the Soft-Keyboard:

command on the remote host.

host system.

Defines the horizontal frequency for a video line and depends on the video mode. Different

video card types may require different values here. The default settings in conjunction with the

auto adjustment procedure should be adequate for most common configurations. If the picture

quality is still bad after auto adjustment you may change this setting together with the sampling

Defines the phase for video sampling; used to control the display quality together with the

Lindy 39632 — Remote Console Control Bar diagram (page 15)
Fig. 18 · Remote Console Control Bar

Use the left and right buttons to move the picture in a horizontal direction

Use the left and right buttons to move the picture in a vertical direction

Reset mode specific settings to the factory-made defaults.

Video Settings through the remote console:

Reset all settings to the factory-made defaults.

Controls the brightness of the picture

Controls the contrast of the picture

phase to achieve a better quality.

setting for sampling clock.

Show 17 more labels / short text on this page
Restore last settings · Local Keyboard · Undo Changes · Soft Keyboard · Mapping · Hotkeys · Show · Save changes permanently · Horizontal Offset · Reset this Mode · Reset all Modes · Vertical Offset · Save Changes · Brightness · Contrast · Clock · Phase
Page 16 of the Lindy 39632 user manual — Remote Console Status Line
Page 16 · click to enlarge
Page 16

To open the KVM console, click either the menu entry on the left or on the console picture on

Future firmware updates will allow you to control external RS232 controlled power control

distribution units. Please contact LINDY for further information regarding compatibility,

Should you wish to connect a remote power outlet then LINDY would recommend you to use IP

managed power strips that can be found in the network section of the LINDY website, i.e.

compared to the descriptions in this manual may be found, especially for the design of the

Lindy 39632 — 5.7.1. Remote Control diagram (page 16)
Fig. 19 · 5.7.1. Remote Control

connection and configuration of both LINDY and third party power control distribution units.

progress and are being continuously upgraded accordingly. Therefore minor changes

The KVM over IP Module and its software and firmware are subject to technological

LINDY No. 32657, 32658, 32656, 32654, 32653, 32414, 32415

the right. To refresh the picture, click on the Refresh button.

5.7.1. Remote Control

5.7. Menu Options

screens and menus.

KVM Console

Shows both console and the connection state. The size of the remote screen is displayed. The

example below was taken from a Remote Console with a resolution of 1024 x 768 pixels. The

value in brackets describes the connection to the Remote Console. Norm means a standard

Furthermore, both the incoming (In :) and the outgoing (Out :) network traffic are visible (in

kb/s). If compressed encoding is enabled, a value in brackets displays the compressed transfer

For more information about Monitor Only and Exclusive Access settings, see the relevant

connection without encryption, SSL indicates a secure connection.

Remote Console Status Line

section 5.7.4.

rate.

Technological progress · Remote Power · Status line

Page 17 of the Lindy 39632 user manual — Telnet Console
Page 17 · click to enlarge
Page 17

Starts the terminal pass-through mode for the serial port. The key sequence ‘esc exit’ switches

The following list shows the command mode syntax and usage.

Exits the current session and disconnects from the client

Displays the list of possible commands

Displays the release information

back to the command mode.

The CAT-32 IP firmware features a Telnet server that enables a user to connect via a standard

Telnet client. If the Telnet program is using a VT 100, VT 102 or VT 220 terminal or appropriate

emulation, it is even possible to perform a console redirection, as long as the CAT-32 IP host is

Connecting to the CAT-32 IP is done as usual and as required by the Telnet client, for instance

Replace the IP address by the one that is actually assigned to the CAT-32 IP. This will prompt

for the username and password in order to log into the device. The credentials that need to be

entered for authentication are identical to those of the web interface. That means the user

management of the Telnet interface is entirely controlled with the appropriate functions of the

Once you have successfully logged into the CAT-32 IP a command line will be presented and

In general, the Telnet interface supports two operation modes: the command line mode and the

terminal mode. The command line mode is used to control or display some parameters. In

terminal mode the pass-through access to serial port 1 is activated (if the serial settings were

made accordingly). All inputs are redirected to the device on serial port 1 and its answers are

Lindy 39632 — Telnet Console diagram (page 17)
Fig. 20 · Telnet Console

you can enter management commands directly.

using a text mode screen resolution.

telnet 192.168.1.22

displayed on the Telnet interface.

Telnet Console

in a UNIX shell:

web interface.

Show 6 more labels / short text on this page
Clears the screen · Terminal · Version · Help · Quit · Cls
Page 18 of the Lindy 39632 user manual — Floppy Disk
Page 18 · click to enlarge
Page 18
Lindy 39632 — 5.7.2 . Virtual Media diagram (page 18)
Fig. 21 · 5.7.2 . Virtual Media

A virtual floppy drive will be installed on the host system and the image will be downloaded to

the virtual floppy drive from the CAT-32 IP. You can access the virtual floppy drive in the same

You can download the image from the CAT-32 IP to your remote system by clicking the

Clicking Discard removes the virtual floppy image from the CAT-32 IP and from the hosts

Lindy 39632 — 5.7.2 . Virtual Media diagram (page 18)
Fig. 22 · 5.7.2 . Virtual Media
Lindy 39632 — 5.7.2 . Virtual Media diagram (page 18)
Fig. 23 · 5.7.2 . Virtual Media

After the image has uploaded you will see the dialog below:

Windows users should use the tool, RawWrite for

Launch RawWrite, you will see the window

Insert your floppy disk into your floppy drive. Click

Select a name and destination for the floppy image

file and click the Read button. As the image is

written, you will see the progress as a percentage

When the image has been written you can upload it

Windows, which is included on the supplied CD.

Click the Browse button and navigate to

the location of the image file, then click

figure in the bottom left hand corner.

the Read tab and then click on

way you would a regular drive.

Uploading a Floppy Image

the Upload button.

Download button.

to the CAT-32 IP.

opposite:

system.

One of the computers connected to the CAT-32 IP can also be set up for remote mass storage

via a USB connection. Files can be uploaded to the switch, which the host computer ‘sees’ as

virtual drives. This means the remote operator can remotely install software, drivers etc. without

Follow the steps below to upload a virtual floppy image to the CAT-32 IP and create a virtual

First, on your client PC you must create an image of your floppy disk which can be uploaded to

To create an image file, make use of dd. This is one of the original UNIX utilities and is included

To create a floppy image file copy the contents of a floppy to a file. You can use the following

dd reads the entire disc from the device /dev/fd0 and saves the output in the specified output

Lindy 39632 — 5.7.2 . Virtual Media diagram (page 18)
Fig. 24 · 5.7.2 . Virtual Media

file /tmp/floppy.image. Adjust both parameters exactly to your needs (input device etc.)

in every UNIX-like OS (UNIX, Sun Solaris, and Linux).

the need to be sat in front of the host computer.

dd [ if=/dev/fd0 ] [ of=/tmp/floppy.image ]

floppy drive on the host system.

the CAT-32 IP’s built in memory.

5.7.2 . Virtual Media

Create a Floppy Image

UNIX and UNIX-like OS

Floppy Disk

command:

Windows

Page 19 of the Lindy 39632 user manual — Create a CD-ROM/ISO Image
Page 19 · click to enlarge
Page 19
Lindy 39632 — 5.7.2 . Virtual Media diagram (page 19)
Fig. 25 · 5.7.2 . Virtual Media
Share hostEnter the IP address of your Console PC here (e.g. 192.168.2.103)
Lindy 39632 — 5.7.2 . Virtual Media diagram (page 19)
Fig. 26 · 5.7.2 . Virtual Media
Share nameTest (The share name of the previously created folder)
Usersuper (Your user name, the default is super)
Passwordpass (Your password, the default is pass)
Path to imageimage.iso (the name of the CD image)
2. Create a folder on your client PC and name it Test. Copy the file image.iso to the folder
3. Now you need to ‘share’ this folder. Right click on the folder and select the option Sharing

and Security. Select Share this folder and

ensure the Share Name is set to Test. Click

Permissions to set permissions for users who

access this folder, according to your

requirements. Click Apply then OK to

4. Next you need to mount the image via a Windows Share. In the CAT-32 IP menu on

the left hand side of the browser select Virtual

To create the image file, use your favorite CD

imaging tool. Copy the whole contents of the disc

For example, with ‘Nero’ choose ‘Copy and

Backup’. Then, navigate to the ‘Copy Disc’

section. Select the CD ROM or DVD drive you

would like to create an image from. Specify the

filename of the image, and save the CD ROM

Media and from the sub menu select CD-

1. Create a CD image and name it image.iso

into one single image file on your hard disk.

5. Input the following parameters:

content in that file.

ROM Image.

complete.

6. Click Set

Example:

Test.

Follow the procedure below to create a CD-ROM image which can be accessed by the host

First, on your client PC you must create an image of your CD which can be accessed by the

To create an image file, make use of dd. This is one of the original UNIX utilities and is included

To create a CD-ROM image file, copy the contents of the CD-ROM to a file. You can use the

dd reads the entire disc from the device /dev/cdrom, and saves the output in the specified

output file /tmp/cdrom.image. Adjust both parameters exactly to your needs (input device etc.).

Lindy 39632 — 5.7.2 . Virtual Media diagram (page 19)
Fig. 27 · 5.7.2 . Virtual Media

system via the CAT-32 IP. The image file must be an ISO file format!

in every UNIX-like OS (UNIX, Sun Solaris, and Linux).

dd [ if=/dev/cdrom ] [ of=/tmp/cdrom.image ]

Create a CD-ROM/ISO Image

UNIX and UNIX-like OS

following command:

host system.

Windows

Page 20 of the Lindy 39632 user manual — SAMBA
Page 20 · click to enlarge
Page 20

The Drive Redirection feature allows the host system to access the CD-Rom drives, hard drives,

To use this feature you need the Drive Redirection Tool which is part of the KVM Vision Viewer

1. To set up Drive Redirection, first install KVM Vision Viewer . After installation launch the application:
Lindy 39632 — 5.7.2 . Virtual Media diagram (page 20)
Fig. 28 · 5.7.2 . Virtual Media
Lindy 39632 — 5.7.2 . Virtual Media diagram (page 20)
Fig. 29 · 5.7.2 . Virtual Media

application included on the supplied CD.

floppy drives etc. on your client PC.

Drive Redirection

8. Click Reactivate . Access the console window and you will see that another CD drive has been installed on the host computer. This is the virtual drive you have just set up. You can

access the uploaded CD image as though it were a regular CD. Click Unset to remove the

If you would like to access the share via SAMBA, SAMBA must be set up properly. You may

either edit the SAMBA configuration file /etc/samba/smb.conf, or use the Samba Web

Lindy 39632 — Drive Redirection diagram (page 20)
Fig. 30 · Drive Redirection

Administration Tool (SWAT) or WebMin to set the correct parameters.

7. You will see the dialog below detailing the active image:

image.

SAMBA

Page 21 of the Lindy 39632 user manual — IMPORTANT
Page 21 · click to enlarge
Page 21
Lindy 39632 — 5.7.2 . Virtual Media diagram (page 21)
Fig. 31 · 5.7.2 . Virtual Media
2. Access the host computer from the Remote Console window. You will see that the redirected drive will now be shown in Windows Explorer:

This option allows you to disable the mass storage emulation (and hide the virtual drive) if no

1. Drive Redirection is only possible with Windows 2000 and later versions. 2. Drive Redirection works on a low SCSI level. The SCSI protocol cannot recognize partitions; therefore the whole drive selected will be shared instead of any
Lindy 39632 — 5.7.2 . Virtual Media diagram (page 21)
Fig. 32 · 5.7.2 . Virtual Media
Lindy 39632 — 5.7.2 . Virtual Media diagram (page 21)
Fig. 33 · 5.7.2 . Virtual Media

image file is currently loaded. To set this option, press the button Apply.

1. Choose the drive you wish to redirect from the drop-down list. Enter your user name and

Write Support is selected, data on the

shared media may be lost!

particular partition.

password and click OK.

IMPORTANT

Options

2. Click on the Search for new devices icon - The CAT-32 IP will be detected as an Unconfigured device and its MAC address will be displayed in the left panel. Double click
3. Follow the on-screen instructions. You will be asked to input your user name (default is super ) and password (default is pass) .
4. Continue with the Wizard until the device is correctly configured. Once the configuration is complete, select Redirect Local Drive from the Device menu:
Lindy 39632 — IMPORTANT diagram (page 21)
Fig. 34

on the MAC address to launch the Device Configuration Wizard.

Lindy 39632 — IMPORTANT diagram (page 21)
Fig. 35
Page 22 of the Lindy 39632 user manual — Change Password
Page 22 · click to enlarge
Page 22

The CAT-32 IP comes with 2 pre-configured user accounts that have fixed permissions. The

super account has all possible rights to configure the device and to use all functions. The user

account has only the permission to open and use the Remote Console. The default password

for both accounts is "pass". Ensure you change the passwords as soon as you have installed

Select an existing user for modification. Once a user has been selected, click the lookup button

Lindy 39632 — 5.7.2 . Virtual Media diagram (page 22)
Fig. 36 · 5.7.2 . Virtual Media

While the user account never sees the following options, the super account can change the

The password for the login name. It must be at least four characters long.

and accessed the CAT-32 IP for the first time.

The new user name for the selected account.

name and password for both accounts.

Confirmation of the above password.

to see the user information.

Users And Groups

To change your password, enter the new password in the upper entry field. Retype the

Lindy 39632 — Users And Groups diagram (page 22)
Fig. 37 · Users And Groups

password in the lower field. Click Apply to submit your changes.

5.7.3. User Management

Change Password

Show 4 more labels / short text on this page
Confirm password · New User name · Existing users · Password
Page 23 of the Lindy 39632 user manual — User Console
Page 23 · click to enlarge
Page 23

Allows adjustment of both compression rate and colour depth individually. Depending on the

selected compression rate the data stream between the CAT-32 IP and the Remote Console

will be compressed in order to save bandwidth. Since high compression rates are very time

consuming, they should not be used when several users are accessing the CAT-32 IP

The standard colour depth is 16 bit (65536 colours). The other colour depths are intended for

slower network connections in order to allow a faster transmission of data. Therefore

compression level 0 (no compression) uses only 16 bit colour depth. At lower bandwidths only 4

bit (16 colours) and 2 bit (4 grey scales) are recommended for typical desktop interfaces. Photo-

like pictures have best results with 4 bit (16 grey scales). 1 Bit colour depth (black/white) should

Uses the default Java Virtual Machine of your Browser. This may be the Microsoft JVM for

Internet Explorer or the Sun JVM if it is configured this way. Use of the Sun JVM may also be

Lindy 39632 — 5.7.2 . Virtual Media diagram (page 23)
Fig. 38 · 5.7.2 . Virtual Media

only be used for extremely slow network connections.

Specifies, which Remote Console Viewer to use.

forced (see below).

simultaneously.

The following settings are user specific. This means the super user can customize these

settings for individual users separately. Changing the settings for one user does not affect the

This box displays the user ID for which the values are shown and for which the changes will

take effect. You may change the settings of other users if you have the necessary access rights.

The Transmission Encoding setting allows changing the image-encoding algorithm that is used

to transmit the video data to the Remote Console window. It is possible to optimize the speed of

the remote screen depending on the number of users working at the same time and the

The encoding and the compression level are determined automatically from the available

The pre-configured settings deliver the best result because of optimized adjustment of

Lindy 39632 — 5.7.2 . Virtual Media diagram (page 23)
Fig. 39 · 5.7.2 . Virtual Media

bandwidth of the connection line (Modem, ISDN, DSL, LAN, etc.).

compression and colour depth for the indicated network speed.

bandwidth and the current content of the video image.

5.7.4. KVM Settings

settings for the other users.

User Console

Show 7 more labels / short text on this page
Remote Console Type · Default Java-VM · Manually · Transmission Encoding · Automatic detection · User select Unit · Pre-configured
Page 24 of the Lindy 39632 user manual — Keyboard/Mouse
Page 24 · click to enlarge
Page 24

Enables the interface the mouse is connected to. You can choose between Auto for automatic

To enable USB remote keyboard access during the boot process of the host, the following

Enables a certain keyboard layout. You can choose between Generic 101-Key PC for a

standard keyboard layout, Generic 104-Key PC for a standard keyboard layout extended by

three additional windows keys, Generic 106-Key PC for a Japanese keyboard, and Apple

managed host and the managing device. If the managed host has no USB keyboard support

Lindy 39632 — 5.7.2 . Virtual Media diagram (page 24)
Fig. 40 · 5.7.2 . Virtual Media

and you selected Auto as host interface, then USB will be selected if available, otherwise it

keyboard access during the boot process of the host. If USB and PS/2 are both connected

in the BIOS and you have connected the USB cable only, then you will have no remote

the USB cable must be connected or must be selected in the Host interface option

detection, USB for a USB mouse, or PS/2 for a PS/2 mouse.

the host BIOS must have USB keyboard support

Macintosh for the Apple Macintosh.

conditions must be fulfilled:

Keyboard/Mouse

will revert to PS/2.

Instructs the web browser of your administration system to use Sun’s JVM. The JVM in the

browser is used to run the code for the Remote Console window which is actually a Java

Applet. If you check this box for the first time on your administration system and the appropriate

Java plug-in is not already installed on your system, it will be downloaded and installed

automatically. However, in order to make the installation possible, you still need to answer the

appropriate dialogs with yes. The download size is around 11MB. The advantage of

downloading Sun's JVM is in providing a stable and identical Java Virtual Machine across

different platforms. The Remote Console software is optimized for Sun JVM versions and offers

Allows the user to specify a hotkey combination which starts either the mouse synchronization

This allows simulating keystrokes on the remote system that cannot be generated locally. The

reason for this might be a missing key or the fact that the local operating system of the Remote

Console is unconditionally catching this keystroke already. Typical examples are

Control+Alt+Delete in Windows and DOS, which is always caught, or Control+Backspace on

confirm requests confirmation by a dialog box before the key strokes will be sent to the remote

keycode is the key to be sent. Multiple key codes can be joined with a plus, or a minus sign.

The plus sign builds key combinations; all keys will be pressed until a minus sign or the end of

the combination is encountered. In this case all pressed keys will be released in reversed

sequence. So the minus sign builds single, separate key presses and releases. The star inserts

Start in Monitor Mode Sets the initial value for the monitor mode. By default the

monitor mode is off. In case you switch it on, the Remote Console window will be

Start in Exclusive Access Mode Enables the exclusive access mode

immediately at Remote Console startup. This forces the Remote Consoles of all

other users to close. No one can open the Remote Console at the same time

Linux for terminating the X-Server. The syntax to define a new Button Key is as follows:

process if pressed in the Remote Console or is used to leave the single mouse mode.

again until this user disables the exclusive access or logs off.

wider range of functionality when run with JVM.

Miscellaneous Remote Console Settings

Sun Microsystems Java Browser Plug-in

a pause with duration of 100 milliseconds.

started in a read only mode.

Remote Console Button Keys

host.

Show 4 more labels / short text on this page
PS/2 Keyboard Model · Host Interface · [confirm] <keycode>[+|-[*]<keycode>]* · Mouse hotkey
Page 25 of the Lindy 39632 user manual — Video
Page 25 · click to enlarge
Page 25

To support signal transmission from a Sun machine, enable this option. If not enabled the

The Network Settings panel allows network related parameters to be changed. Each parameter

will be explained below. Once applied the new network settings will immediately come into

Changing the network settings of the KVM over IP module might result in losing connection to

it. In case you change the settings remotely make sure that all the values are correct and you

Lindy 39632 — 5.7.2 . Virtual Media diagram (page 25)
Fig. 41 · 5.7.2 . Virtual Media

picture of the remote console will not be visible. To set the options, click Apply.

Force Composite Sync (Required for Sun Computers)

still have an option to access the KVM over IP module.

special procedure in the beginning of Section 5.

5.7.5. Device Settings

Network

effect.

Enables USB mouse type. Choose between MS Windows 2000 or newer for MS Windows

2000 or Windows XP, or Other Operating Systems for MS Windows NT, Linux, or OS X. In MS Windows 2000 or newer mode the remote mouse is always synchronized with the local

Auto mouse speed Use this option if the mouse settings on the host use an additional

acceleration setting. The CAT-32 IP tries to detect the acceleration and speed of the mouse

Fixed mouse speed Use a direct translation of mouse movements between the local and

You may also set a fixed scaling which determines the amount the remote mouse pointer is

moved when the local mouse pointer is moved by one pixel. This option only works when the

mouse settings on the host are linear. This means that there is no mouse acceleration involved.

This option defines how the CAT-32 IP reacts to small changes in the video input signal. A large

filter setting needs less network traffic and leads to a faster video display, but small changes in

some display regions may not be recognized immediately. A small filter displays all changes

really changing (depending on the quality of the video input signal). In general the default

instantly but may lead to a constant amount of network traffic even if the display content is not

Lindy 39632 — Network diagram (page 25)
Fig. 42 · Network

settings should be suitable for most situations.

To set the options, click on the Apply button.

during the mouse sync process.

the remote pointer.

mouse.

Video

Show 4 more labels / short text on this page
Miscellaneous Video Settings · USB Mouse Type · Mouse Speed · Noise filter
Page 26 of the Lindy 39632 user manual — Dynamic DNS
Page 26 · click to enlarge
Page 26

A freely available Dynamic DNS service (dyndns.org) can be used in the following scenario (see

The CAT-32 IP is reachable via the IP address of the DSL router, which is dynamically assigned

by the provider. Since the administrator does not know the IP address assigned by the provider,

the CAT-32 IP connects to a special dynamic DNS server in regular intervals and registers its IP

address there. The administrator may contact this server as well and pick up the same IP

The administrator has to register a CAT-32 IP that is supposed to take part in the service with

the Dynamic DNS Server and assign a certain hostname to it. He will get a nickname and a

password in return. This account information, together with the hostname, is needed in order to

Enable Dynamic DNS and change the settings according to your needs (see the next page).

Lindy 39632 — 5.7.2 . Virtual Media diagram (page 26)
Fig. 43 · 5.7.2 . Virtual Media

Make sure that the LAN interface of the CAT-32 IP is properly configured.

You have to perform the following steps in order to enable Dynamic DNS:

Open the Dynamic DNS Settings configuration dialog

determine the IP address of the registered CAT-32 IP.

address belonging to his device.

Dynamic DNS

With this option you can control if the CAT-32 IP should obtain its network settings from a

DHCP or BOOTP server. For DHCP, select dhcp, and for BOOTP select bootp. If you choose

In case the CAT-32 IP is accessible from networks other than the local one, this IP address

IP address of the primary Domain Name Server in dot notation. This option may be left empty;

IP address of the secondary Domain Name Server in dot notation. It will be used in case the

Port number at which the CAT-32 IP’s Remote Console server and HTTPS server are listening.

Port number at which the CAT-32 IP’s HTTP server is listening. If left empty the default value

Port number at which the CAT-32 IP’s Telnet server is listening. If left empty the default value

The maximum network traffic generated through the CAT-32 IP’s Ethernet device. Value in

Set this option to allow access to ARA express using the Telnet Gateway (see the Section

however, the CAT-32 IP will not be able to perform name resolution.

Enable this option to exclude the CAT-32 IP from the setup protocol.

must be set to the local network router's IP address.

none then IP auto configuration is disabled.

Primary DNS Server cannot be contacted.

If left empty the default value will be used.

IP address in the usual dot notation.

Secondary DNS Server IP Address

The net mask of the local network.

Remote Console and HTTPS port

Primary DNS Server IP Address

will be used.

will be used.

Kbit/s.

Show 11 more labels / short text on this page
illustration below) · Disable Setup Protocol · called Telnet Console) · IP auto configuration · Bandwidth limitation · Enable Telnet access · Gateway IP address · Subnet Mask · IP address · HTTP port · Telnet port
Page 27 of the Lindy 39632 user manual — Security
Page 27 · click to enlarge
Page 27

If this option is enabled, access to the web front-end is only possible using an HTTPS

This option controls the encryption of the RFB protocol. RFB is used by the Remote Console to

transmit both the screen data to the administrator’s machine and the keyboard and mouse data

back to the host. If set to "Off" no encryption will be used. If set to "Try", the applet will attempt

to establish an encrypted connection. If connection establishment fails for any reason an

unencrypted connection will be used. If set to Force the applet tries to make an encrypted

Lindy 39632 — 5.7.2 . Virtual Media diagram (page 27)
Fig. 44 · 5.7.2 . Virtual Media

connection. The CAT-32 IP will not listen on the HTTP port for incoming connections.

connection. An error will be reported if connection establishment fails.

Security

This is the server name where the CAT-32 IP registers itself in regular intervals. At the time of

This is the hostname of the CAT-32 IP that is provided by the Dynamic DNS Server. (Use the

You have registered this username during your manual registration with the Dynamic DNS

whole name including the domain, e.g. testserver.dyndns.org not just the actual hostname).

Lindy 39632 — Security diagram (page 27)
Fig. 45 · Security

Enables the Dynamic DNS service. This requires a configured DNS server IP address.

This is the interval for reporting again to the Dynamic DNS server by the CAT-32 IP.

The password used during manual registration with the Dynamic DNS Server.

writing, this is a fixed setting since only dyndns.org is currently supported.

setting is correct. (See the Section called Date and Time on page 59)

The CAT-32 IP registers itself in the Dynamic DNS server at this time.

Server. Spaces are not allowed in the nickname.

Show 9 more labels / short text on this page
KVM encryption · Force HTTPS · Enable Dynamic DNS · Dynamic DNS server · Check interval · Check time · Hostname · Username · Password
Page 28 of the Lindy 39632 user manual — Certificate
Page 28 · click to enlarge
Page 28

After completing these three steps, the CAT-32 IP has its own certificate that is used to identify

This is the network name of the CAT-32 IP once it is installed in the user's network It is identical

to the name that is used to access the CAT-32 IP with a web browser (without the “ http:// ”

prefix). In case the name given here and the actual network name differ, the browser will pop up

This field is used for specifying to which department within an organization the CAT-32 IP

The country where the organization is located. This is the two-letter ISO code, e.g. DE for

Some certification authorities require a challenge password to authorize later changes on the

certificate (e.g. revocation of the certificate). The minimal length of this password is 4

case you deleted it by mistake, you have to repeat the three steps as described previously.

Lindy 39632 — 5.7.2 . Virtual Media diagram (page 28)
Fig. 46 · 5.7.2 . Virtual Media

a security warning when the CAT-32 IP is accessed using HTTPS.

The name of the organization to which the CAT-32 IP belongs.

The state or province where the organization is located.

The city where the organization is located.

Germany, or US for the USA.

it to its clients.

characters.

belongs.

The CAT-32 IP uses the Secure Socket Layer (SSL) protocol for any encrypted network traffic

between itself and a connected client. During the connection establishment the CAT-32 IP has

This certificate and the underlying secret key is the same for all CAT-32 IP units and certainly

will not match the network configuration that will be applied to the CAT-32 IP by its user. The

certificate's underlying secret key is also used for securing the SSL handshake. Hence, this is a

However, it is possible to generate and install a new certificate that is unique for a particular

CAT-32 IP. In order to do this, the CAT-32 IP is able to generate a new cryptographic key and

the associated Certificate Signing Request (CSR) that needs to be certified by a certification

authority (CA). A certification authority verifies that you are the person you claim you are, and

1. Create an SSL Certificate Signing Request using the panel shown in the screen shot above. You need to fill out a number of fields that are explained on the next page. Once

this is done, click on the Create button to initiate the Certificate Signing Request

generation. The CSR can be downloaded to your administration machine with the

2. Send the saved CSR to a CA for certification. You will get the new certificate from the CA after a more or less complicated traditional authentication process (depending on the

The following steps are necessary to create and install an SSL certificate for the CAT-32 IP:

Lindy 39632 — 5.7.2 . Virtual Media diagram (page 28)
Fig. 47 · 5.7.2 . Virtual Media
3. Upload the certificate to the CAT-32 IP switch using the Upload button.

Download CSR button (see the illustration on the next page).

to expose its identity to a client using a cryptographic certificate.

security risk (but far better than no encryption at all).

signs and issues a SSL certificate to you.

Certificate

CA).

Show 7 more labels / short text on this page
Challenge Password · Organizational unit · Country (ISO code) · Common name · State/Province · Organization · Locality/City
Page 29 of the Lindy 39632 user manual — Serial Port
Page 29 · click to enlarge
Page 29

The CAT-32 IP Serial Settings allow you to specify what device is connected to the serial port

The CAT-32 IP offers remote access using a telephone line in addition to the standard access

over the built-in Ethernet adapter. The modem needs to be connected to the serial interface of

Connecting to the CAT-32 IP using a telephone line allows you to set up a dedicated point-to-

point connection from your console computer to the CAT-32 IP. In other words, the CAT-32 IP

acts as an Internet Service Provider (ISP) to which you can dial in. The connection is

established using the Point-to-Point Protocol (PPP). Before you connect to the CAT-32 IP,

make sure you configure your console computer accordingly. For instance, on Windows based

operating systems you can configure a dial-up network connection, which defaults to the right

The Modem Settings panel allows you to configure remote access to the CAT-32 IP using a

modem. The meaning of each parameter will be described below. The modem settings are part

Lindy 39632 — 5.7.2 . Virtual Media diagram (page 29)
Fig. 48 · 5.7.2 . Virtual Media

Do not use the serial port for any special function; use it only for the initial configuration

Configuration or console login

of the serial settings panel.

and how to use it.

settings like PPP.

the CAT-32 IP.

Serial Port

This is the length of the generated key in bits. 1024 bits are sufficient for most cases. Longer

The email address of a contact person that is responsible for the CAT-32 IP and its security.

keys may result in slower response time by the CAT-32 IP during connection establishment.

Confirmation of the Challenge Password

Show 4 more labels / short text on this page
Modem · Confirm Challenge Password · Key length · Email
Page 30 of the Lindy 39632 user manual — Date And Time
Page 30 · click to enlarge
Page 30

Here you can set the internal real-time clock of the CAT-32 IP. You can adjust the clock

manually or use an NTP timeserver. Without a timeserver your time setting will be lost if the

CAT-32 IP is powered down for more than a few minutes. To avoid this, you can use an NTP

timeserver which sets up the internal clock automatically to the current UTC time. Because the

NTP server time is always UTC, there is a setting that allows you to set up a static offset to get

Lindy 39632 — 5.7.2 . Virtual Media diagram (page 30)
Fig. 49 · 5.7.2 . Virtual Media

have to set up the UTC offset according to the local conventions of your country.

Date And Time

your local time.

The speed the CAT-32 IP is communicating with the modem. Most modems available today

will support the default value of 115200 bps. In case you are using an old modem and

The initialization string used by the CAT-32 IP to initialize the modem. The default value will

work with all modern standard modems directly connected to a telephone line. In case you

have a special modem or the modem is connected to a local telephone switch that requires

a special dial sequence in order to establish a connection to the public telephone network,

you can change this setting by entering a new string. Refer to your modem’s manual about

This IP address will be assigned to the CAT-32 IP during the PPP handshake. Since it is a

point-to-point IP connection virtually every IP address is possible but you must make sure, it

is not interfering with the IP settings of the CAT-32 IP and your console computer. The

This IP address will be assigned to your console computer during the PPP handshake.

Since it is a point-to-point IP connection virtually every IP address is possible but you must

make sure, it is not interfering with the IP settings of the CAT-32 IP switch and your console

Using this option, it is possible to connect an arbitrary device to the serial port and access it

(assuming it provides terminal support) via Telnet. Select the appropriate options for the serial

port and use the Telnet Console, or a standard Telnet client to connect to the CAT-32 IP.

computer. The default value will work in most cases.

discovering problems try to lower this speed.

Pass-through access to serial port via Telnet

default value will work in most cases.

Modem server IP address

Modem client IP address

the AT command syntax.

Modem Init String

Serial line speed

Page 31 of the Lindy 39632 user manual — Event Log
Page 31 · click to enlarge
Page 31

With this option, the CAT-32 IP is able to send Emails to an address given by the Email address

text field in the Event Log Settings. These mails contain the same description strings as the

internal log file and the mail subject is filled with the event group of the occurred log event. In

order to use this log destination you have to specify an SMTP server that has to be reachable

If this is activated, the CAT-32 IP sends an SNMP trap to a specified destination IP address

every time a log event occurs. If the receiver requires a community string, you can set it in the

appropriate text field. Most of the event traps only contain one descriptive string with all

information about the log event. Only authentication and host power events have a trap class

that consists of several fields with detailed information about the occurred event. To receive

limited. Every log event will be appended to the end of the file so it grows continuously, so you

from the CAT-32 IP and that needs no authentication at all (:).

these SNMP traps, any SNMP trap listener may be used.

may have to delete it or move it from time to time.

destinations. Each of those events belongs to an event group, which can be activated

In the Event Log Settings you can choose how many log entries are shown on each page.

The common way to log events is to use the internal log list of the CAT-32 IP. To show the log

Since the CAT-32 IP’s system memory is used to save all the information, the maximum number

of possible log list entries is restricted to 1000 events. Every entry that exceeds this limit

Defines an NFS server to write all logging data to a file that is located there. To write logging

data from multiple CAT-32 IP units to only one NFS share, you have to define a file name that is

unique for each device. When you change the NFS settings and press Apply, the NFS share

will be mounted immediately. That means, the NFS share and the NFS server must be filled

logging information is saved permanently and is available after the module has been started.

If the KVM over IP module loses power or a hard reset is performed, all logging data will be

Lindy 39632 — 5.7.2 . Virtual Media diagram (page 31)
Fig. 50 · 5.7.2 . Virtual Media
Lindy 39632 — 5.7.2 . Virtual Media diagram (page 31)
Fig. 51 · 5.7.2 . Virtual Media

lost. To avoid this, use one of the log methods described below.

list, click on Event Log on the Maintenance page.

Furthermore, you can clear the log file here.

with valid sources or you will get an error.

overrides the oldest one.

Event Log

separately.

Show 4 more labels / short text on this page
SMTP Logging enabled · SNMP Logging enabled · NFS Logging enabled · List logging enabled
Page 32 of the Lindy 39632 user manual — Device Information
Page 32 · click to enlarge
Page 32

The CAT-32 IP is a complete standalone computer. The software it runs is called the firmware.

The firmware of the CAT-32 IP can be updated remotely in order to install new functionality or

Lindy 39632 — 5.7.2 . Virtual Media diagram (page 32)
Fig. 52 · 5.7.2 . Virtual Media
Lindy 39632 — 5.7.2 . Virtual Media diagram (page 32)
Fig. 53 · 5.7.2 . Virtual Media

Displays the log list including the events that are logged by the CAT-32 IP.

Update Firmware

special features.

Event Log

Lindy 39632 — Event Log diagram (page 32)
Fig. 54 · Event Log

This section contains a summary showing various information about the CAT-32 IP and its

Allows you to download the CAT-32 IP data file with specific support information. This is an

XML file with certain customized support information like the serial number etc. You can send

The example below displays the CAT-32 IP activity. From left to right the connected user(s), its

IP address (from which host the user comes from) and its activity status is displayed. RC means

that the Remote Console is open. If the Remote Console is opened in exclusive mode the term

(exclusive) is added. For more information about this option see the section called Remote

Lindy 39632 — Event Log diagram (page 32)
Fig. 55 · Event Log

this information if you contact LINDY technical support. It may help us solve any problems.

current firmware. It also allows you to reset the unit.

To display the user activity, the

last column contains either the

term active for an active user

or 20 min idle for a user who

is inactive for a certain amount

View the data file for support

5.7.6. Maintenance

Device Information

Console Control Bar.

of time.

Connected Users

Page 33 of the Lindy 39632 user manual — Unit Reset
Page 33 · click to enlarge
Page 33

This section allows you to reset specific parts of the device. This involves the keyboard and

Resetting the unit itself is mainly needed to activate a newly updated firmware. It will close all

The whole process will take about half a minute. Resetting sub devices (e.g. the video engine)

will take a few seconds only and does not result in connections closing. To reset individual CAT-

Lindy 39632 — 5.7.2 . Virtual Media diagram (page 33)
Fig. 56 · 5.7.2 . Virtual Media

current connections to the administration console and to the Remote Console.

mouse, the video engine and the CAT-32 IP itself.

32 IP functionality, click on the Reset button.

New firmware updates are provided as a binary file which can be sent to you by email. Please

contact LINDY Technical Support team in your preferred country should you need to update

your firmware. Please note that an error during a firmware update may cause damage to the

1. The new firmware file is uploaded to the CAT-32 IP. In order to do this you need to select the file on your local system using the Browse button on the Upload Firmware panel. Once

the firmware file has been uploaded it is checked whether it is a valid firmware file and

whether there were any transmission errors. In case of any error the Upload Firmware

2. If everything went well you will see the Update Firmware panel. The panel shows you the version number of the currently running firmware and the version number of the uploaded
3. After the firmware has been stored, the CAT-32 IP will automatically reset itself. Half a minute after the reset the CAT-32 IP will run with the new firmware version and should be
4. Once you have logged in we recommend you delete the Temporary Internet Files from your browser to ensure that the appearance of the web interface is correct. To do this in

and may take some minutes. Make sure the Cat-32 IP’s power supply will not be interrupted

users or administrators should perform the firmware update. This process is not reversible

when updating the firmware is very unlikely. However, we recommend only experienced

firmware. Pressing the Update button will replace the old version with the new one.

update please use the Reset Keyboard/Mouse option in the Maintenance section.

unit, therefore a firmware update should only be performed if it is really necessary.

Tick the check boxDelete all offline content , and click OK

Tools > Internet Options > General > Delete Files

accessible. However, you will be required to login once again.

Updating the firmware is a four stage process:

Internet Explorer, select:

during the update process!

function will be aborted.

Unit Reset

Page 34 of the Lindy 39632 user manual — KVM Switch Troubleshooting
Page 34 · click to enlarge
Page 34

Please check if you have an option like ‘Automatically move mouse pointer to the default

button of dialog Unites’ enabled in the mouse settings of the operating system. This option

8. In the browser the CAT-32 IP switch pages are inconsistent. Clear Temporary Internet Files from your browser. To do this in Internet Explorer, select:

You have to define a so-called Button Key. This can be done in the Remote Console

7. Special key combinations, e.g. ALT+F2, ALT+F3 are intercepted by the console system and not transmitted to the host.
9. Windows XP doesn’t wake from standby mode This could be a Windows XP problem. Try not to move the mouse while XP goes into
10. Every time I open a dialog box with some buttons, the mouse pointers are not synchronised anymore
Tick the check boxDelete all offline content , and click OK

Tools > Internet Options > General > Delete Files

needs to be disabled.

standby mode.

settings.

Troubleshooting

cable between KVM switch and Computer Access Module. Try replacing the cable, or use a

and the password is pass. Furthermore, your browser must be configured to accept cookies.

numbers 443 or 80 are open for incoming TCP connections. Install the latest version of Java

6. No connection can be established to the CAT-32 IP. Check whether the network connection is working in general (ping the IP address of CAT-32

IP). If not, check the network hardware. Is the CAT-32 IP powered on? Check whether the IP

3. If the Monitor picture is not sharp or shows shadows: Please check the quality of the UTP

Sync option from the Mouse Handling sub menu of the Remote Console Options menu.

4. Login on CAT-32 IP switch fails. Was the correct combination of user and password given? The default user name is super

address of CAT-32 IP switch and all other IP related settings are correct! Also verify that all

If none of the port LEDs or the display on the KVM Switch are illuminated then please check

1. The remote mouse doesn’t work or is not synchronized Make sure the mouse settings in CAT-32 IP match the mouse model. Use the Intelligent
3. The video quality is bad or the picture is grainy Try to correct the brightness and contrast settings until they are out of a range where the

Before you check any further please make sure that all cables are fitted correctly!

1. If the problem is also is visible from the local console please first refer to section 3.4
2. Please check if the currently selected computer is in sleep mode or powered down.
5. The Remote Console window can’t connect to the CAT-32 IP. Possibly a firewall prevents access to the Remote Console. Make sure the TCP port

picture looks grainy. Use the auto adjustment feature to correct a flickering video.

the IP infrastructure of your LAN, including routers etc., is correctly configured.

2. The remote mouse does not work correctly Try using the Reset Keyboard/Mouse option in the Maintenance section .

that the power adapter is connected and switched on at the mains.

4. If you have forgotten a Password please contact LINDY.

Troubleshooting

KVM Switch Troubleshooting

IP Access Troubleshooting

higher quality cable.

Troubleshooting.

Virtual Machine.

Troubleshooting

Page 35 of the Lindy 39632 user manual — Key Codes
Page 35 · click to enlarge
Page 35

The layout for this keyboard is also shown. However, most modifier keys and other

alphanumeric keys used for hotkey purposes in application programs are in an identical

position, no matter what language mapping you are using. Some of the keys have aliases also;

Lindy 39632 — 5.7.2 . Virtual Media diagram (page 35)
Fig. 57 · 5.7.2 . Virtual Media

they can be named by 2 key codes (separated by a comma in the previous table).

NUMPADMINUS,NUMPAD MINUS

NUMPADPLUS,NUMPAD PLUS

NUMPADMUL,NUMPAD MUL

PRINTSCREEN

NUMPADENTER

BACK SPACE

\, BACK SLASH

LSHIFT, SHIFT

LCTRL, CTRL

ESCAPE, ESC

SCROLL LOCK

PAGE DOWN

=, EQUALS

CAPS LOCK

NUM LOCK

WINDOWS

-, MINUS

/, SLASH

LALT, ALT

PAGE UP

NUMPAD0

NUMPAD1

NUMPAD2

NUMPAD3

NUMPAD4

NUMPAD5

NUMPAD6

NUMPAD7

NUMPAD8

NUMPAD9

NUMPAD/

, TILDE

<, LESS

ENTER

RCTRL

RSHIFT

SPACE

ALTGR

BREAK

INSERT

HOME

DELETE

DOWN

RIGHT

MENU

0 - 9 A - Z

TAB

END

LEFT

F1

F2

F3

F4

F5

F6

F7

F8

F9

F10

F11

F12

UP

This table shows the key codes used to

defines keystrokes or hotkeys for

several functions. Please note that these

key codes do not necessarily represent

key characters that are used on

international keyboards. They name a

key on a standard 104 key PC keyboard

Key Codes

with US English language mapping.

Show 7 more labels / short text on this page
Technical Information · Technical Information · ; · ’ · , · [ · ]
Page 36 of the Lindy 39632 user manual — Video Modes
Page 36 · click to enlarge
Page 36

In 2006 the European Union introduced regulations (WEEE) for the collection and recycling of all waste electrical and electronic equipment.

Each individual EU member state has implemented the WEEE regulations into national law in slightly different ways. Please follow your

Die Europäische Union hat mit der WEEE Direktive umfassende Regelungen für die Verschrottung und das Recycling von Elektro- und

Elektronikprodukten geschaffen. Diese wurden von der Bundesregierung im Elektro- und Elektronikgerätegesetz – ElektroG in deutsches

Dieses Gesetz verbietet vom 24.März 2006 an das Entsorgen von entsprechenden, auch alten, Elektro- und Elektronikgeräten über die

Hausmülltonne! B2B Geräte wie diese KVM Switches nimmt LINDY kostenlos zurück und führt sie einem geordneten Recycling zu. Bitte

En 2006, l'union Européenne a introduit la nouvelle réglementation (DEEE) pour le recyclage de tout équipement électrique et

Chaque Etat membre de l’ Union Européenne a mis en application la nouvelle réglementation WEEE de manières légèrement différentes.

Nel 2006 l’unione europea ha introdotto regolamentazioni (WEEE) per la raccolta e il riciclo di apparecchi elettrici ed elettronici. Non è più

Ogni stato membro dell’ EU ha tramutato le direttive WEEE in leggi statali in varie misure. Fare riferimento alle leggi del proprio Stato

It is no longer allowed to simply throw away electrical and electronic equipment. Instead, these products must enter the recycling process.

This device complies with the European Regulations for Electromagnetic Compatibility (EMC) of the European Union and it is equipped with

the CE mark. This unit has to be used with high quality shielded connection cables. Only if these high quality shielded cables are used can

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction

Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause

harmful interference, and (2) this device must accept any interference received; including interference that may cause undesired operation.

Shielded cables must be used with this equipment to maintain compliance with radio frequency energy emission regulations and ensure a

Veuillez suivre le décret d’application correspondant à l’élimination des déchets électriques ou électroniques de votre pays.

WEEE (Waste of Electrical and Electronic Equipment), Recycling of Electronic Products

nehmen Sie hierzu Kontakt mit LINDY auf, die Adressen finden Sie auf der LINDY Website www.lindy.com

Per ulteriori dettagli fare riferimento alla direttiva WEEE sul riciclaggio del proprio Stato.

consentito semplicemente gettare queste apparecchiature, devono essere riciclate.

national law when you want to dispose of any electrical or electronic products.

More details can be obtained from your national WEEE recycling agency.

manual, may cause harmful interference to radio communications.

it be sure that the EMC compatibility is not adversely influenced.

suitably high level of immunity to electromagnetic disturbances.

quando si dispone di un apparecchio elettrico o elettronico.

FCC Statement

interference at their own expense.

CE Statement

Recht umgesetzt.

électronique.

environment.

The table below lists the video modes that the CAT-32 IP remote console supports. Please do

Higher resolutions than 1280 x 1024, i.e. 1600x1200 may be displayed in virtual desktop mode

not use any other custom video settings; the CAT-32 IP may not be able to detect them.

640 x 350 70, 85 640 x 400 56, 70, 85 640 x 480 60, 67, 72, 75, 85, 90, 100, 120 720 x 400 70, 85 800 x 600 56, 60, 70, 72, 75, 85, 90, 100 832 x 624 75 1024 x 768 60, 70, 72, 75, 85, 90, 100 1152 x 864 75 1152 x 870 75 1152 x 900 66 1280 x 960 60 1280 x 1024 60, 75

Resolution (x, y) Refresh Rates (Hz)

Video Modes

with a moving visible area of 1280 x 1024.

Show 7 more labels / short text on this page
Certifications, Recycling Information · Germany / Deutschland · United Kingdom · FCC Warning · France · Italy · Technical Information
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Lindy 39632

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Lindy 39632

Be the first to ask — other owners or our team will answer.

Original document

Lindy 39632 manual PDF

36 pages·2.8 MB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…