Instruction/ maintenance manual of the product INVERTEC SVM129-B Lincoln Electric
Go to page of 145
SVM129-B OCTOBER, 2006 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind. However , your overall safety can be increased by proper installation .
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FOR ELECTRICALL Y powered equipment. 8.a. T urn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions d.
MASTER T ABLE OF CONTENTS FOR ALL SECTIONS v v INVERTEC STT Page Safety .................................................................................................................................................i-iv Installation ................
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T ABLE OF CONTENTS - INST ALLA TION SECTION - Section A-1 Section A-1 INVERTEC STT Installation .......................................................................
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INST ALLA TION A-2 A-2 INVER.
INST ALLA TION A-3 A-3 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Mas.
INST ALLA TION A-4 A-4 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ELECTRIC SHOCK can kill. • Only qualified personnel should perform this installation.
INST ALLA TION A-5 A-5 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Mas.
A-6 INST ALLA TION A-6 INVERTEC STT II FIGURE A.2 RECONNECT P ANEL I NPUT VOL T AGE RECONNECT PROCEDURE As shipped from the factory , multiple voltage machines are internally configured for the highest input voltage (440-460 V AC), for Codes 1 1092 and below and (380- 415 V AC), for Codes 1 1 1 15 and 1 1 1 16.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section B-1 Section B-1 INVERTEC STT T ABLE OF CONTENTS - OPERA TION SECTION - Operation ..............................................................................
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC B-2 B-2 INVERTEC STT ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrode with skin or wet clothing.
OPERA TION B-3 B-3 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC GENERAL DESCRIPTION The Invertec STT II is a 225-ampere inverter based arc welding power source specifically designed for the STT welding process.
OPERA TION B-4 B-4 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 1. POWER SWITCH: T urns output power ON and OFF.
OPERA TION B-5 B-5 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 6. WIRE SIZE SELECT SWITCH: This toggle switch selects between electrode diameters of .
OPERA TION B-6 B-6 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC WELDING P ARAMETERS AND GUIDE- LINES The Invertec STT II is neither a constant current (CC) nor a constant voltage (CV) power source.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OPERA TION B-7 B-7 INVERTEC STT WELDING PROCEDURES FOR STT II - (Steel) Horizontal Fillet (See T able B.
NOTES B-8 B-8 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T ABLE OF CONTENTS - ACCESSORIES - Accessories ........................................................................................................................
ACCESSORIES C-2 C-2 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC STT control board to accept PEAK and BACK- GROUND inputs on this connector rather than from the front panel controls.
ACCESSORIES C-3 C-3 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC LN-742 or STT -10 WIRE FEEDER CONNECTION INSTRUCTIONS The LN-742 or STT -10 is the recommended wire feed- er for use with the Invertec STT II.
C-4 C-4 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ACCESSORIES CONNECTION DIAGRAM - INVERTEC STT II 4-9-99 M17657-3 CABLES AND LEADS SHOULD ELECTRODE LEAD BE TAPED TOGETHER.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section D-1 Section D-1 INVERTEC STT T ABLE OF CONTENTS -MAINTENANCE- Maintenance .....................................................................................
MAINTENANCE D-2 D-2 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC W ARNING Failure to follow this capacitor discharge proce- dure can result in electric shock.
MAINTENANCE D-3 D-3 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PREVENTIVE MAINTENANCE 1. Perform the following preventive mainte- nance procedures at least once every six months.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC MAINTENANCE D-4 D-4 INVERTEC STT 12 4 17 5 6 9 8 7 10 16 15 13 18 14 19 11 1 3 2 FIGURE D.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section E-1 Section E-1 INVERTEC STT Theory of Operation ............................................................................................................. Section E General Description .
GENERAL DESCRIPTION The Invertec STT is a 225 ampere, inverter based, arc welding power supply specifically designed for the Surface T ension T ransfer (STT) welding process. It cannot be classified as either a constant current (CC) or a constant voltage (CV) machine.
RECONNECT , PROTECTION BOARD, RECTIFICA TION AND PRECHARGE The reconnect panel allows the user to switch to low or high input voltage to match the input line voltage. The AC input voltage is rectified and applied to the driver board. The driver board contains precharging circuitry for safe charging of the input filter capacitors.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC THEOR Y OF OPERA TION E-4 E-4 INVERTEC STT NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC THEOR Y OF OPERA TION E-5 E-5 INVERTEC STT FIGURE E.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC THEOR Y OF OPERA TION E-6 E-6 INVERTEC STT FIGURE E.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC THEOR Y OF OPERA TION E-7 E-7 INVERTEC STT FIGURE E.
FIELD EFFECT TRANSISTOR (FET) OPERA TION An FET is a type of transistor . FET s are semiconduc- tors well suited for high-frequency switching. Drawing A above shows an FET in a passive mode. There is no gate signal, zero volts relative to the source and, therefore, no current flow .
PULSE WIDTH MODULA TION The term PULSE WIDTH MODULA TION is used to describe how much time is devoted to conduction in the positive and negative portions of the cycle.
PROTECTIVE CIRCUITS Protective circuits are designed into the Invertec machine to sense trouble and shut down the machine before the trouble damages the internal machine com- ponents.
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section F-1 Section F-1 INVERTEC STT T roubleshooting & Repair Section ................................................................................ Section F How to Use T roubleshooting Guide .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC HOW TO USE TROUBLESHOOTING GUIDE Service and repair should be performed by only Lincoln Electric Factory T rained Personnel.
ELECTRIC SHOCK can kill. Have an electrician install and service this equipment. T urn the machine OFF before working on equipment. Do not touch electrically hot parts. Sometimes machine failures appear to be due to PC board failures. These problems can sometimes be traced to poor electrical connections.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-4 F-4 INVERTEC STT Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-5 F-5 INVERTEC STT TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-6 F-6 INVERTEC STT Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-7 F-7 INVERTEC STT TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-8 F-8 INVERTEC STT TROUBLESHOOTING & REP AIR TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-9 F-9 INVERTEC STT Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-10 F-10 INVERTEC STT TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-11 F-11 INVERTEC STT Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-12 F-12 INVERTEC STT TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AI.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-14 F-14 INVERTEC STT T1 AUXILIARY TRANSFORMER PLUG J31 PLUG J30 FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-15 F-15 INVERTEC STT 5. Locate the primary lead molex plug (J21) just behind the reconnect panel assembly on the right side of the machine.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-16 F-16 INVERTEC STT 8. If the correct secondary voltages are present (according to T able F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-17 F-17 INVERTEC STT ELECTRIC SHOCK can kill. • With input power ON, there are high voltages inside the machine.
NOTES F-18 F-18 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T4 AUXILIAR Y TRANSFORMER TEST Service and repair should be performed by only Lincoln Electric factory trained personnel.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-20 F-20 INVERTEC STT T4 AUXILIAR Y TRANSFORMER TEST (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-21 F-21 INVERTEC STT T4 AUXILIAR Y TRANSFORMER TEST (continued) 5.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-22 F-22 INVERTEC STT T4 AUXILIAR Y TRANSFORMER TEST (continued) 7.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-23 F-23 INVERTEC STT T4 AUXILIAR Y TRANSFORMER TEST (continued) 1 1.
13. Check the secondary AC voltages accord- ing to T able F .2. 14. With the correct 1 15V AC applied to the pri- mary winding (#32 to #33), if any or all of the secondary voltages are missing or low , the T4 auxiliary transformer may be faulty . Replace the T4 auxiliary transformer .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INPUT RECTIFIER TEST Service and repair should be performed by only Lincoln Electric factory trained personnel.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-26 F-26 INVERTEC STT INPUT RECTIFIER TEST (continued) FIGURE F .
6. Replace the input rectifier when any of the tests are NOT OK. NOTE: When installing a new input rectifier , torque the mounting nuts (in a cross-tightening pattern) to 6 inch-pounds (.7 Nm). T orque ter- minals to 26 inch-pounds (3 Nm). PROCEED T O STEP 7 T O CHECK RELA TED COMPO - NENTS .
NOTES F-28 F-28 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CAP ACITOR BALANCE TEST Service and repair should be performed by only Lincoln Electric factory trained personnel.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-30 F-30 INVERTEC STT CAP ACITOR BALANCE TEST (continued) FIGURE F .
5. Adjust the Peak and Background controls to the minimum settings (controls on case front). 6. Jumper together pins "C" and "D" on the 14 pin amphenol. This will energize the output terminals. 7. T est for VDC across terminals #9 and #12 of one switch board and repeat the test for the other switch board.
NOTES F-32 F-32 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SWITCH BOARD TEST Service and repair should be performed by only Lincoln Electric factory trained personnel.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-34 F-34 INVERTEC STT SWITCH BOARD TEST (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AI.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AI.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SNUBBER RESISTORS TEST Service and repair should be performed by only Lincoln Electric factory trained personnel.
TROUBLESHOOTING & REP AIR F-38 F-38 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SNUBBER RESISTORS TEST (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-39 F-39 INVERTEC STT SNUBBER RESISTORS TEST (continued) FIGURE F .
NOTES F-40 F-40 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC POWER BOARD TEST Service and repair should be performed by only Lincoln Electric factory trained personnel.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-42 F-42 INVERTEC STT POWER BOARD TEST (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-43 F-43 INVERTEC STT POWER BOARD TEST (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-44 F-44 INVERTEC STT POWER BOARD TEST (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PROTECTION BOARD TEST Service and repair should be performed by only Lincoln Electric factory trained personnel.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-46 F-46 INVERTEC STT PROTECTION BOARD TEST (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-47 F-47 INVERTEC STT FIGURE F .18 - LEADS #309, #309A A T CR1, CR2 RELA YS CR2 CR1 309A 309 PROTECTION BOARD TEST (continued) 7.
NOTES F-48 F-48 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TRIGGER CIRCUIT TEST Service and repair should be performed by only Lincoln Electric factory trained personnel.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-50 F-50 INVERTEC STT TRIGGER CIRCUIT TEST (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-51 F-51 INVERTEC STT TRIGGER CIRCUIT TEST (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-52 F-52 INVERTEC STT TRIGGER CIRCUIT TEST (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC IGBT MODULE REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory trained personnel.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-54 F-54 INVERTEC STT IGBT MODULE REMOV AL AND REPLACEMENT (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-55 F-55 INVERTEC STT IGBT MODULE REMOV AL AND REPLACEMENT (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-56 F-56 INVERTEC STT IGBT MODULE REMOV AL AND REPLACEMENT (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-57 F-57 INVERTEC STT IGBT MODULE REMOV AL AND REPLACEMENT (continued) FIGURE F .
NOTES F-58 F-58 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SWITCH BOARD REPLACEMENT Service and repair should be performed by only Lincoln Electric factory trained personnel.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-60 F-60 INVERTEC STT SWITCH BOARD REPLACEMENT (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-61 F-61 INVERTEC STT SWITCH BOARD REPLACEMENT (continued) 6.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AI.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-63 F-63 INVERTEC STT SWITCH BOARD REPLACEMENT (continued) ELECTRIC SHOCK can kill.
NOTES F-64 F-64 INVERTEC STT Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CAP ACITOR REMOV AL AND REPLACEMENT PROCEDURE Service and repair should be performed by only Lincoln Electric factory trained personnel.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-66 F-66 INVERTEC STT CAP ACITOR REMOV AL AND REPLACEMENT PROCEDURE (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-67 F-67 INVERTEC STT CAP ACITOR REMOV AL AND REPLACEMENT PROCEDURE (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-68 F-68 INVERTEC STT CAP ACITOR REMOV AL AND REPLACEMENT PROCEDURE (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-69 F-69 INVERTEC STT CAP ACITOR REPLACEMENT NOTE: Capacitors must always be replaced in matched sets (C1 and C2 as a set).
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-70 F-70 INVERTEC STT 15. Place the machine on its side as shown in Figure F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-71 F-71 INVERTEC STT 17. Remove the two 7/16” hex bolts that hold the capacitor to the switch board.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-72 F-72 INVERTEC STT 19. Install the new capacitor and tighten the two 7/16” hex bolts to a torque of 55 inch-pounds (6 Nm).
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OUTPUT RECTIFIER REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory trained personnel.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-74 F-74 INVERTEC STT OUTPUT RECTIFIER REMOV AL AND REPLACEMENT (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-75 F-75 INVERTEC STT OUTPUT RECTIFIER REMOV AL AND REPLACEMENT (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-76 F-76 INVERTEC STT OUTPUT RECTIFIER REMOV AL AND REPLACEMENT (continued) FIGURE F .
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AI.
INPUT FIL TER CAP ACITOR CONDITIONING If the machine will not produce output when turned on and the following two conditions exist: The machine is connected to operate at an input voltage of 380 V AC or higher and Power has not been applied to the machine for a long period of time (many months).
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INVERTEC STT Section G-1 Section G-1 T ABLE OF CONTENTS - ELECTRICAL DIAGRAMS SECTION - Electrical Diagrams ...........................................................
G-2 ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II + - ELECTRICAL SYMBOLS PER E1537 H1 T 1 FAN MO TOR G F E J A I K C D M L B N H 75 76 77 31 32 41 42 2 4 81 82 21 GND SPARE 42 V AC T3 CURRENT TRA.
G-3 ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II R 3 2A 3 2B 15 1 6 J 22 R B 1 8V 32C 43A R U 3 18V 501 B 504 W 4 5 5 275 1 8 6 3 3 11 10 J 6 1 212A 9 7 212 352 212B 503A Y 301 305 245 223 8 11 .
G-4 ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II G-4 Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Ma st e r T O C R.
G-5 ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II + - ELECTRICAL SYMBOLS PER E1537 12 34 1 3 4 6 1 61 0 5 { 1 4 8 5 H1 T1 FAN MOTOR G F E J A I K C D M L B N H 7 5 7 6 77 31 32 41 42 2 4 81 82 21.
G-6 ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II J28 1 1 50V 0.1 C413 +15V_REM 50V 0.1 C 411 +15V_REM REM REM 3.92K R463 METER_2 METER_1 PB_SCALED 1.00K R436 3.92K R461 J28 10 J28 6 J 28 3 1 5.0K R437 10.0K R431 OCI4 Vcc GND HP2231 5 8 1.00K R432 0.
G-7 ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II G-7 Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Ma st e r T O C R.
ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Ma st e r T O C Re tur n .
G-9 ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II G-9 Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Ma st e r T O C R.
G-10 ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II G-10 Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Ma st e r T O C.
ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Ma st e r T O C Re tur n .
G-12 ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II X4 14 13 12 P6 J6 4 267 R24 4.75K R23 P6 J6 5 D12 5.11K R25 D10 D8 C11 P6 J6 10 LM350 ADJ OUT IN X5 33.2K R13 J14 4 D11 500 50V C10 15.0K R14 P6 J6 9 15J 50V TP2 D9 C7 X4 1 2 3 Ch'ge.Sht.No.
ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II CAPACITORS = MFD/VOLTS ITEM REQ'D P ART NO. I DENTIFICATION INDUCTANCE = HENRYS D C B F E POWER BOARD X 1 X5 C1 C3 C10 X4 TP2 TP1 J6 J14 J7 OCI1.
G-14 ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II ON 2 PLACE DECIMALS IS + .O2 WITH PUBLISHED STANDARDS ON HOLES SIZES PER E-2056 SUPPLY POWER Ch'ge.
ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II J12 J13 R15 R18 R17 R16 R14 R13 R10 R12 R9 R11 DZ1 C17 Q1 R6 D4 D1 D3 D2 R1 C12 C15 C16 OCI1 D5 R3 R2 D10 D11 D 12 D13 R8 D6 D7 D8 D 9 C10 C9 Q2 C8 DZ3 R7 C14 X2 C5 DZ2 R5 R4 C6 S TT DARLINGTON DRIVE I TEM REQ'D PART NO.
G-16 ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II G-16 Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Ma st e r T O C.
ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Ma st e r T O C Re tur n .
G-18 ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II W W R 6 00mA 40V Q7 1W 3.3V DZ5 1 .00K R12 1/2W 1 R15 100V 1A Q2 600mA 40V Q6 15.0K R10 50V 2700p C2 47.5 R 35 1N4936 D9 600mA 40V Q5 1W 10V DZ1 1N4936 D3 1 W 6.2V DZ6 1 00V 1 A Q3 1W 10V DZ3 1/2W 1 R11 1.
ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Ma st e r T O C Re tur n .
G-20 ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II G-20 Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Ma st e r T O C.
ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Ma st e r T O C Re tur n .
G-22 ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II G-22 Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Ma st e r T O C.
ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Ma st e r T O C Re tur n .
G-24 ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II G-24 Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Ma st e r T O C.
ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Ma st e r T O C Re tur n .
G-26 ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II G-26 Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Ma st e r T O C.
ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Ma st e r T O C Re tur n .
G-28 ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II G-28 Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Ma st e r T O C.
ELEC TRICAL DIA GRAMS INVER TEC S TT & S TT II Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Se ct io n T OC Re tur n to Ma st e r T O C Re tur n .
An important point after buying a device Lincoln Electric INVERTEC SVM129-B (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Lincoln Electric INVERTEC SVM129-B yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Lincoln Electric INVERTEC SVM129-B - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Lincoln Electric INVERTEC SVM129-B you will learn all the available features of the product, as well as information on its operation. The information that you get Lincoln Electric INVERTEC SVM129-B will certainly help you make a decision on the purchase.
If you already are a holder of Lincoln Electric INVERTEC SVM129-B, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Lincoln Electric INVERTEC SVM129-B.
However, one of the most important roles played by the user manual is to help in solving problems with Lincoln Electric INVERTEC SVM129-B. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Lincoln Electric INVERTEC SVM129-B along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center