REMOVE FROM CHARGER
Lightspeed microphones require 8
CHANNEL SELECT
Two microphones cannot operate LT-
POSITION MICROPHONE
The position of the microphone is critical for proper volume adjustment.
TURN ON MICROPHONE
L
SET VOLUME
If necessary adjust volume so you REMEMBER: Volume set too high
TURN OFF AND RETURN TO CHARGER
Interface seamlessly with computers, MP3, DVD, TV and other audio devices.
Use your microphone to remotely connect audio to your system.
Grip the barrel of the handheld in the center section.
Send audio directly to an Assistive Listening Device (ALD) or to a digital recorder for lesson capture and re-broadcast on school websites. Always connect to the MIC or AUX input jack.
Confirm proper batteries are used. The REDMIKE requires the Lightspeed BA-NH2A27 sensing battery for proper charging.
TIPS ON CLASSROOM AUDIO
1Speak in a natural voice. A normal conversational speech level will provide an adequate signal. It is not necessary to increase the intensity of your voice—the audio system provides adequate amplification (approximately 5 – 10 dB) above ambient room noises.
2Avoid wearing jewelry that may rub or bump against the microphone.
3Turn off the REDMIKE during private conversations with a student, parent, or other classroom visitor. You can also cover the LED lens on top of the REDMIKE to block the signal.
4Recharge batteries each night. When recharged nightly, operating time (actual usage) for the transmitters will last through a typical school day.
Five-year Limited Warranty
Lightspeed Classroom Audio Systems are guaranteed against malfunction due to defects in materials and workmanship for a period of FIVE (5) YEARS, beginning at the date of the purchase invoice. If such malfunction occurs, the product will be repaired or replaced (at Lightspeed’s option) without charge during the warranty period. 1. Warranty on infrared microphones is FIVE (5) YEARS. 2. Warranty on Lightspeed rechargeable batteries, all external cables and wires provided by Lightspeed is one (1) year. 3. Prepaid shipping labels are provided by Lightspeed factory or an authorized warranty service center for warranty repairs. 4. Warranty does not extend to finish, appearance items, or malfunctions due to abuse or operation other than specified conditions, nor does it extend to incidental or consequential damages. Repair by other than Lightspeed or its authorized service agencies will void this guarantee. Information on authorized service agencies is available from Lightspeed Technologies, Inc.
Our Service Department (800.732.8999, 5 a.m. – 5 p.m., PST) will handle all your repair/replacement needs.
Make sure the REDMIKE is turned off while charging so that it will attain a full charge. Full charge will last seven hours.
Inspect the battery contacts. Clean and adjust if necessary.
Hearing Static
Ensure REDCAT is in optimum location (refer to REDCAT placement in manual). A single REDCAT will cover a 1200 sq. ft. enclosed classroom.
Ensure that no other REDMIKE/LT71/ HM70 is operating on the same channel.
If an external microphone is in use, try another REDMIKE that is known to be working (if available) to isolate the problem. If static persists with “known good” microphone, the REDMIKE input jack will need service.
Low Volume or Feedback
Ensure microphone is positioned appropriately, just below the collar bone.
Check volume level on the amplifier. If the volume is too high, feedback will occur. Adjust accordingly.
No Sound From Speaker
Ensure the REDCAT is plugged in and is turned on. Confirm that the POWER light located on the power switch is on.
Confirm signal is being received at the REDCAT. The IR signal light will be lit (RED) indicating a signal is being received.
Confirm that REDMIKE is turned on. There will be a BLUE LED on the microphone to indicate it is powered on.