O w n e r ’ s M a n u a l
Standard Warranty
The Titan D100 Fault Free Warranty is $300. Contact your Light & Motion reseller or Light & Motion directly to activate your Fault Free Warranty.
The expressed warranty set forth herein is in lieu of all other warranties expressed or implied, including without limitation any warranties of merchantability or fitness for a particular purpose, and all such warranties are hereby disclaimed and excluded by the manufacturer. Repair or replacement of defective items as provided above is the sole and exclusive remedy provided hereunder. Light & Motion will not be liable for any further loss, damages, or expenses, including incidental or consequential damages directly or indirectly arising from the sale or use of this product.
The Fault-Free Warranty does not cover the following: Loss of product as the result of theft, misplacement, or other cause. Accessories, monitors, accessories lenses and pointer lights, chargers, parts such as lamps, O-rings, and batteries that are wear items. Damage due to tampering or repair by a non-authorized shop or person. Import duties, customs clearance fees, and general expenses involving shipping to Light & Motion. Light & Motion reserves the right to choose the return shipping method of warranted products. Expedited shipping charges are purchaser's responsibility.
These warranties extend only to the original purchaser through Light & Motion or an authorized dealer.
For 24 months from warranty purchase date this product is warranteed against any physical damage or harm, from any cause, regardless of the fault of purchaser, limited only by intentional damage. During the Fault-Free Warranty period, any damage to or defects in this product will be repaired and any adjustments needed for the product to conform full to factory prescribed standards will be made, without charge. At our option, the product will be replaced without charge (but only once during the Fault-Free Warranty period, and only if the serial number is recognizable). If the product is replaced under the Fault-Free Warranty due to customer negligence or internal disruption of the product, the replacement product will be covered only by the Extended Warranty (up to the end of the original Fault- Free Warranty period). Also included in the Fault-Free Warranty is one Light & Motion Annual Service.
Products not manufactured by Light & Motion, such as strobes and strobe arms, are not cov- ered under the Light& Motion warranty. These products are covered by the Terms and Conditions set forth by their respective manufacture.
Light & Motion provides a limited warranty to the original purchaser against all defects in original workmanship and material, under normal use and service, for one year from the date of purchase, with the following exceptions: Lamps are warranted for 30 days, batteries are warranteed for 90 days, and battery chargers are warranteed for use only in the US and Canada. Using a battery charger in conjunction with a voltage converter is NOT considered normal use and chargers are not warranteed under such conditions. Light & Motion will not be liable for any further loss, damages, or expenses, including incidental or consequential damages directly or indirectly arising from the sale or use of this product.




Illustrated below are the locations of Titan’s features, ports, and functions.Take time to familiarize yourself with the housing.
Camera Preparation
First Time Use
1. Remove the camera’s strap from the camera. 2. Attach the desired lens for use. 3. Remove the camera’s lens cap. 4. Remove the rubber accessory cap from the bottom of the camera (Fig. 1). The Titan’s camera tray has a pocket for the cap to be stored when the camera is on the tray (Fig3). 5. Remove the hotshoe cover. 6. Place battery board onto camera battery (Read next section “Battery Board”). 7. Install a fully charged EN-EL3 camera battery. 8. Install a media card.We recommend at least a 1GB size card.
After the initial dive with just the housing, make the following checks. 1. Dry off housing exterior. 2. Remove the Rear Plate and visually inspect for moisture. 3. Reach inside the housing and trace a finger around all view ports and mating surfaces. 4. If any water is detected, contact the housing reseller or the Light & Motion service department.
You can also contact Light & Motion to purchase replacement battery boards. Replacment Battery Boards are p/n # 825-0188.
Eventually the Battery Board’s adhesive will exhaust.When this occurs, you can simply “drop-in” the board into the camera’s battery compartment.You may need to guide the board into place.
The Battery Board adhesive is meant to be strong enough to hold the board onto the battery, yet easy to remove when attaching the battery to a charger.
You received two battery boards with your Titan D100 housing. One is a spare and can be stored inside the Titan’s rear plate (Fig. 7 & 8).
The Titan D100’s Battery Board is the component that allows the Titan’s “Focus” button (located on the right handle) to function. No other housing functions are affected. If you choose not to use the Battery Board, you can use the mechanical shutter for auto-focus.
All Light and Motion housings are pressure tested prior to shipping. However, there could be unseen damage from shipping.A test dive without the camera in the housing is highly recommended.









10. Pull the Titan’s Mode Dial up.Pull and rotate the Focus/Zoom gear to the neutral position (Fig 14). 11. Rotate the Titan’s Focus Mode selector lever to the C position (lever down Fig. 15). 12. Install the camera tray. Guide the camera tray onto the two tray rails. Continue to push until the Camera Tray Latch engages the guide pin and locks the tray (Fig 16). 13. Turn the housing Mode Dial to match the position of the camera and press down. 14. Check the alignment and operation of all handle functions, housing controls, the focus/zoom gear alignment, and the MSC Lever. 15. Turn the Metering Mode Selector on the Rear Plate to match the camera’s. 16. Check both O-rings on the Titan’s Rear Plate and check the sealing surface on the Titan hull, then replace the Rear Plate. 17. When sealing the Rear Plate, rotate both latchs evenly. 18. Check all handle and housing functions.
1. Remove the rear plate by holding both latch locks in and simultaneously rotating both latches down and rearward of the housing body (Fig. 9). 2. Remove the camera tray. Press the Camera Tray Latch to the left and pull the tray backward out of the housing (Fig 10). 3. Remove the accessory cap from the bottom of the camera. Place the cap in the retaining pocket in the camera tray for easy retrival. 4. Place the battery board onto the camera battery if you haven’t already done so. 5. Install the battery into the camera. 6. Place the camera’s focus selector in the C position (Fig. 11). Rotate the focus selector gears on the camera tray so the gear opening is oriented at the six O’clock position (Fig 12.). 7. Place the D100 onto the camera tray, align the tripod screw and accessory jack, and tighten tripod screw into camera.Tighten the screw with a coin. 8. Rotate the focus selector gears to ensure they engage properly on the camera. If the gears are not operating correctly, remove the camera from the tray, realign the gear with the camera’s lever and reattach the camera to the tray. 9. Attach hotshoe cable from tray into hotshoe mount of camera (Fig 13). Guide the cable on the right side of the camera, away from the focus selector gears.
It is very important that the Rear Plate draws in evenly and that the O-rings seat and seal correctly. Check sealing surface on top and bottom to confirm proper seal.
If no LEDs illuminate, re-seat the camera onto the camera tray.Visually check that the camera is seated flush with entire camera tray.Turn on the camera to check connectivity.
Test the connection between the camera and the ROC system by turning the camera on. The ROC LED panel should illuminate with a LED in each power bank and the two green LED back lights.
Battery Board









Rear Plate Controls
Top Controls
Focus / Zoom Neutral Lock: Disengages focus gear when using auto focus (Fig 26).
Focus / Zoom Dial: Engages the lens manual focus or zoom ring (Fig 25).
Enter Button (Fig. 24): Confirms menu selections.
Thumbnail button (Fig. 24): Changes playback image size.
Menu button (Fig. 23):Activates camera’s menu.
Monitor button (Fig. 23): Switches camera to playback mode.
Format (Fig. 22): Use with Back Light button to format media card.
BKT button (Fig. 22):Access camera’s bracketing features.
Trash Can button (Fig. 21): Deletes images during playback.
Arrow Buttons (Fig. 20): Selects area focus, menu and navigates images during playback.
Metering Selector Lever (Fig. 19): Selects camera metering method.
Exposure Compensation (Fig 18):Accesses camera’s exposure compenstation features.
Back Light button (Fig 18): Illuminates the LCD data screen. The Back Light button is also used in combination with the Format Button (located on the Rear Plate) to format the media card when the camera is in the housing.
On Dial (Fig. 18):Turns the camera on. To turn the camera on, turn the On Dial counter-clockwise until it stops. Then press the On Dial down and turn clockwise. Note:The camera can’t be turn off while in the housing.
Mode Dial (Fig 17):Accesses the camera’s Mode Dial. Use the Mode Dial to select camera’s exposure mode. Use the Mode Dial to select the following settings: ISO - White Balance - Image Size - Image Quality - AF Area Mode









Left Smart Grip (Fig. 29)
Front Controls
Also see page 18 to use the AEL/AFL feature of this button.
Focus button will not function if the Battery Board is not installed.
Focus button: Pressing this button is just like pressing the shutter button half way. Activates electronic auto focus (half shutter). Press and hold the Focus button to keep the camera’s focus locked. While holding the Focus button down, pull the shutter release to take a photo.
~ + and ~ - buttons: Right strobe increase or decrease power buttons.
The Sub + / - buttons perform all sub command dial functions.
Sub - button: decreases f/stop in M and A shooting modes.
Sub + button: Increases f/stop in M and A shooting modes.
~ + and~ - buttons: Left strobe increase or decrease power buttons.
L ~ R OFF: Selects strobe control mode and deactivates strobes. Strobe power can be controlled independently from the respective side handle or strobe power can be controlled together from either handle. To control strobes independently, press the button until the ROC LEDs blink separately. Strobe power level is controlled by the handle on the same side. To adjust strobe power together, press the button until both LEDs blink together. Either handle then controls power level for both strobes. To deactivate strobes, press and hold button until Strobe OFF LEDs illuminate. To reactivate strobes, press and release button.
The Main + / - buttons perform all main command dial functions.
Main - button: Decreases shutter speed in M and S shooting modes.
Main + button: Increases shutter speed in M and S shooting modes.
Focus Mode Selector (Fig. 28): Selects camera’s focus mode.
Shutter Lever:Accesses the camera’s shutter button (Fig. 27). The Shutter Lever also activates the camera’s auto focus when depressed half way.When depressed fully, the camera will take a photo.




L R



FOCUS
SUB +
Attaching Sync Cables to Titan
Installing Bulkheads
Attaching Strobes
1. Remove bulkhead cap by inserting a coin into the slot in the cap and turning counter clock wise. 2. Loosen retaining screw and free bulkhead cables (Fig 34). 3. Use a 3/4” wrench to unscrew the bulkhead from the Titan. Carefully pull bulkhead and wires through port in Titan. 4. Check the O-ring and sealing surface of the bulkhead. 5. Insert the wires of the new bulkhead through the port of the Titan. 6. Hand tighten bulkhead into port. 7. Tighten the bulkhead with a 3/4” wrench. 8. Insert the wire plug from the bulkhead in to the connector on the circuit board. 9. Guide bulkhead wires under the retaining bracket and tighten screw. If installed correctly, the bulkheads should be flush to top of housing.
Wetmate sync cords and bulkhead performance is designed to be impervious to water. To ensure long-term performance, flush with fresh water and dry contacts if exposed to salt water. Apply silicone grease to Wetmate contacts
If you decide to dive without strobes attached, disable the strobe signal by using the L ~ R Strobe Off function.
The Titan housing is supplied with two 1” Base Ball Mounts (Fig. 31). Most ball style clamps for strobe arms can readily attach to these base mounts (Fig. 32).
+ · +

Pre-Dive Checklist
ROC - Defined
ROC is powered by the camera’s battery.When the camera is off, ROC is off.
ROC is in STAND-BY after being idle for 60 seconds and power level LEDs are not dis- played. ROC is ready to take a photograph, this is just a power saving mode.To check the power level of the strobes when ROC is in Stand-By mode, press any of the strobe but- tons on either handle.This will not alter the ROC power settings, but will return ROC to an ON status.
ROC is ON when the power level LEDs are displayed.
In addition to the unique strobe control, the Titan D100 handles also offers electronic Auto-Focus,Auto Focus Lock, Area Focus Selection, and control of Command Dials.
ROC is an innovative strobe and camera control interface built into the Titan Housing. ROC allows the underwater photographer to obtain up to 12 manual power levels on most TTL compatible strobes. ROC’s strobe power control spans from full power to -7 f/stops or ROC can disable the strobes from firing. This gives the digital underwater photographer unprecedented flexibility and convenience when lighting subjects. Up to two strobes can be connected to the Titan via Nikonos style or Wetlink style bulkheads. ROC allows the power levels for each strobe to be controlled independently or together.
After 60 seconds of inactivity ROC enters stand-by mode. ROC is still active but turns off the LEDs to conserve battery power. ROC will return to the active mode by pressing any button from either ROC handle or the mechanical shutter.
ROC is fully active when the LEDs are showing strobe power levels.
During the programming process, if programming is idle for 60 seconds ROC will record the strobe profile of the current LED position and enter stand-by mode.
Use the L ~ R Strobe button to select and program both strobes simultaneously or to program the left and right strobes independently (Fig 37). If both LED are moving, both strobes are being programmed. If only one LED is moving, only one strobe is being programmed. The Left and right LED banks program the left and right strobes respectively.
ROC’s default strobe profile is for Sea & Sea YS-90DX/90/60/50. If you are using different strobe(s) use the following procedure to change the ROC strobe profile.
ROC can only function successfully by knowing the type of strobe(s) being used. It is necessary to program ROC prior to using the Titan underwater. Once ROC is programmed it will never have to be reprogrammed unless a different model strobe is used. ROC will retain its programming even when the ROC is in the off status.

(Fig. 37) (Fig. 38)

Press together and hold to save strobe profile.
Press strobe select button to adjust LEDs together or independently.
Press together and hold to enter programming mode.
L R
OFF
L R
OFF
L R

Press either button to move ROC LED position.
F = Empty – = Ikelite 400 -1 = Ikelite 200 – = Ikelite DS-125 -2 = Ikelite 100 – = Ikelite DS-50/50 -3 = Nikonos SB-105 – = Nikonos SB-104 -4 = Sea & Sea YS-350/300 -5 = Sea & Sea YS-120 -6 = Sea & Sea YS-90DX/90/60/50 -7 = Sea & Sea YS-30
L R
1. Turn strobe(s) on and in the TTL position. 2. Press the +/- buttons on the respective handles to adjust strobe power (Fig. 40). To adjust strobe power levels together, press the L/R Strobe button and watch for power LEDs to blink together.Then press the +/- button from either handle to adjust strobe power for both strobes (Fig. 41). To return to adjusting the strobe power levels independently,press the L/R Strobe button and watch for the power LEDs to blink separately.Then press the +/- button from the respective handle to adjust that side strobe power. 3. Press the + button to increase the strobe’s power or the - button to decrease the strobe’s power.
To return the Focus button to half-shutter return the menu focus setting to its prior setting and press the Sub + and Strobe + buttons until the handle LED blinks twice.
The camera will keep focus locked at the same distance until the Focus button is pressed again.Then the camera will readjust the focus distance.
To use the auto focus lock, press the Focus button. The camera will auto focus and continue to refocus as long as the button is held down.When the camera is focused at the appropriate distance, release the Focus button.
This is a two step process and will change the default, half shutter, function of the Focus button to the AE-L / AF-L function.
The default setting for the Focus button is half-shutter. Pressing this button is the same as pressing the camera’s shutter release half-way. The Focus button can also be reporogrammed to be the camera’s AE-L / AF-L button.While in this mode pressing the handle’s Focus button is the same as pressing the AE-L / AF-L button on the camera.
To deactivate the strobe from firing, press and hold the L ~ R Strobe button on the left handle until the Strobe Off LEDs illuminate (Fig. 42). Press and release the L ~ R button to re-activate strobes.
The default strobe control settings for ROC has the strobes being controlled independently from the respective handle. ROC will revert to this setting every time it enters the OFF state or when the camera is removed from the tray and ROC loses power. ROC will always retain the last programmed strobe profile even when power is removed.





To change focus zones: First Press and hold the Focus button.
LED will blink four times when switching to AEL-AFL mode.
Press these buttons to increase or decrease strobe power.




Press and hold both buttons to enter “AEL-AFL” mode.
Press strobe select button to adjust strobes together or independently.
Then press the “Sub -” button to change focus zones.
Attaching Light & Motion Ports / Conversion Rings
Changing D100 Lenses
Light & Motion ports and gears are made for Nikon Lenses. The following lenses are suported; 14mm, 16mm, 18mm, 20mm, 24mm, 17-35mm, 60mm, 105mm and 12-24 DX.
Refer to the instructions that were packaged with your gear set for gear installation.
The Titan D100 has a lens release mechanism that allows you to change camera lenses with the camera inside the Titan housing.
This feature requires the Focus button to be set up in the AE-L / AF-L function outlined in the previous section.


(Fig. 52) (Fig. 53)

(Fig. 50) (Fig. 51)



1. Identify the appropriate parts in the Titan Modeling Light Kit. 2. Kit includes the following. Hex screw, 1/4” base piece, Infinity arm, modeling light and light bracket. 3. Position the base piece details on the detail of the Titan’s accessory hole. 4. Place the hex screw through the base piece and tighten with hex key (Fig. 53). 5. Place Infinity arm with holder over the base piece and press firmly down until the Infinity arm snaps into position (Fig. 54). 6. Place Modeling light in to light bracket. Replacing ROC Handle Batteries
1. Using a 3/32 hex key, remove the two hex screws on the back of the handle (Fig. 55). 2. Remove the Handle Cap from the handle assembly. 3. Remove old batteries from handle board. 4. Install new 1/3 N batteries into the handle board (Fig. 56) 5. Service Handle Cap O-ring or replace with a new O-ring. 6. Press the Handle Cap into the handle assembly so O-ring seals evenly. 7. Replace both hex screws in Handle Cap and tighten using hex key.
1. Identify the appropriate parts in the Titan mounting kit included with the Mod Light. 2. Titan Kit includes the following. Hex screw, split washer, metal washer, 1/2” hexogonal base piece, and hex key. 3. Place the hex screw through the split washer and metal washer. 4. Place both the hex screw and both metal washers together through the round end of the base piece (Fig. 51). 5. Place the base assembly over the accessory hole of the Titan. 6. Orient the base piece so the hexogonal shape of the base piece matches the hexogonal detail of the Titan and so the hex screw rests on top of the accessory mount. 7. Tighten the entire assembly by tightening the hex screw into the Tetra’s accessory hole
ROC Handle O-ring and Battery Kit (part # 802-0117) Kit contains one O-ring, 3/32 hex key, and two batteries for one ROC Handle.
Replacing the handle batteries is an easy procedure. However, pay special attention to the wear of the O-ring and to the orientation of the batteries.You will need to purchase the ROC Handle O-ring battery kit (P/N 802-0117)
The handles will signal when the battery power is becoming low. The handle LED will blink eight times after any button is pressed.This is a signal to change the batteries prior to the next dive.
The battery life of your ROC Handles will vary depending on usage and technique. But eventually the handle batteries will exhaust.






Replacing Handle Thread Rings
If water touches the Moisture Alarm contact, clean throughly and check for corrosion.
The moisture alarm will continue it’s display of lights until it no longer detects water and one of the handle buttons is pressed.
The two metal contacts are located inside the Titan, in the front and slightly to the left (Fig.59).If water touches these contacts the ROC LED panel will display an array of lights. Immediately move the Titan to a dry location.
The Titan’s moisture alarm (Fig. 59) gives a visual indication that water has been detect- ed inside of the housing.
Handle Thread Ring Replacement Kit contains: 2 - Handle Thread Ring, 2 - snap rings and 1 - spanner wrench.
Follow the steps below to replace the Handle Thread Ring and reattach the handle.
Contact your dealer for a Handle Thread Ring Replacement Kit (p/n 802-0147) or contact the Light & Motion Service department at 831-645-1572.
The Handle Thread Rings that attach the ROC handles (Fig. 57) to the Titan housing are designed to absorb shock should the Titan be dropped or fall. If the Handle Thread Rings experience extreme pressure,they will break and minimize potential damage to the Titan.

Don’t abandon your Titan D100 in the rinse tank!!! It’s not uncommon for another housing or camera to be carelessly dropped into the rinse tank. Other equipment falling onto your Titan D100 can scratch ports or damage the housing body. O-ring Care and Maintenance
4) To check o-rings for damage, place the o-ring between the index finger and thumb.Then pull the o-ring through your fingers, feeling for any debris or wear. 5) If o-rings are dirty, it is best to replace them.Washing dirty o-rings with soap and water is not recommended. Soap breaks down the lubricants and will compromise the integri- ty of the seal. 6) Properly greased o-rings will help maintain sealing integrity and minimize o-ring degra- dation. Use enough grease to lubricate the o-ring thoroughly, but not so much that it will attract additional debris. 7) Clean the groove with a lint free swab or the folded edge of a paper towel. 8) Return O-ring to respective groove. Titan D100 O-ring Replacement Kit part # 854-0129, includes two o-rings for the Rear Plate, two O-rings for a port and 1/4 oz. of O-ring grease.
1) The sealing system used on the rear plate incorporates two o-rings.This is the most crit- ical area of the housing for maintenance and should be inspected before every dive. 2) Make sure the rear plate o-rings and the mating surface on the inside of the main hous- ing are clean from grit, hair, lint and anything that could potentially breach the o-ring seal. 3) After frequent diving or if o-rings appear dirty, remove o-rings and clean the grooves.To remove o-rings, use finger pressure or the rounded edge of a plastic card to lift the o- ring out of the groove.
Follow these steps for proper o-ring care.
Never use a metal object to remove an o-ring. It will cause dam- age to the o-ring and mating surface.
O-rings are the critical component that keeps water out of the housing. Routinely inspect o-rings and replace at least once a year. If your o-rings are damaged, contact the Light & Motion service department for an o-ring replacement kit.
Handle Strobe Base Mounts 854-0104
Handle Thread Ring Replacement Kit 854-0147
Smart Grip Battery and O-ring Kit 854-0117
Titan D100 O-ring Kit 854-0129
Titan D100 Neoprene Dome Port Cover 854-0149
Titan D100 Body Cap 854-0148
Titan D100 Electronics Replacment Kit 854-0152
Titan Pointer Light 854-0051
Sunray Mod Light 850-0049
Titian D100 Custom Travel Case 775-0019
Tetra Wetlink Sync Cord (Sea & Sea only) 854-0044
Titan D100 Fault Free Warranty 905-0200

Returning Products for Care
We highly recommend a factory annual service to maintain prop- er operation of your Titan Housing
European Service Center FEP Ltd. Attn: Steve Mawle Aston House Heimdon Rd. Sulgrave OX17-2SQ England 1295 768686 (ph.) 1295 768446 (fax) info@fep.co.uk www.fep.co.uk