Do not self-diagnose your condition using the measured
Precision components were used in the construction of
Follow the proper cleaning instructions as outlined in
this manual. Do not submerse body of thermometer in
this device. Extremes in temperature, humidity, shock
In order to obtain an accurate measurement, please read
through the ear canal. DO NOT use it to take rectal,
This ear thermometer is a delicate electronic device.
Do not force the thermometer tip into the ear canal.
This thermometer is designed to take a temperature
Do not use the ear thermometer if there is blood or
Only the tip of the ear thermometer is waterproof.
result. Consult your doctor if your temperature is
Do not use the ear thermometer in an infected ear.
Do not expose thermometer to direct sunlight.
Keep this device out of the reach of children.
this instruction manual carefully before using.
Do not disassemble the ear thermometer.
higher than the normal temperature.
drainage in the external ear canal.
oral or underarm temperature.
or dust should be avoided.
water or any other liquid.
Please handle with care.


HOW THE EAR THERMOMETER WORKS E-4
WHAT DISPLAY SYMBOLS MEAN E-2
COMPONENTS E-3
BEFORE YOU START E-5
TAKING YOUR TEMPERATURE E-6
SWITCHING THE UNIT OF MEASURE E-7
CARE AND CLEANING E-8
REPLACING THE BATTERY E-8
FREQUENTLY ASKED QUESTIONS E-9
SPECIFICATIONS E-10
TWO YEAR LIMITED WARRANTY E-11
CONTACT INFORMATION E-12
?
UT-202 Instant-Read Ear Thermometer. This easy to
way to take a temperature measurement through the
ear. It is an especially convenient method of taking a
use thermometer offers a safe, accurate and quick
committed to providing you and your family with
monitoring devices specifically designed for high
A&D Medical has been manufacturing quality
healthcare products for over 20 years. We are
child’s temperature and perfect for adults too.
accuracy and ease of use.



60.8° F – 104.0° F (16° C – 40° C) then
measure again.
page E-6.
UT202_composite 2/5/03 3:40 PM Page 6
out of range (60.8° F –
after 1 minute of non-
Temperature is out of
93.2° F/34° C) Temperature is out of

confident of the measurements when you or a family member is ill.
104.0° F (16° C - 40° C). If the ear thermometer is stored in an environment where the temperature is out of that range, move the
lens may cause an inaccurate measurement. Clean the lens with
abrasive cleaner. Never submerge the body of the thermometer
104.0° F (16° - 40° C). Allow the thermometer to equalize to that temperature range before use.
It is within 30 minutes after eating, taking a bath or physical
We recommend you practice with the LifeSource ear thermometer
a soft, alcohol moistened cloth or cotton swab. Never use an
on yourself and family members while you are healthy. This way
thermometer to a location with a room temperature of 60.8 F -
This product is intended for household use only. If you have
questions about the meaning of a specific temperature, please
Use the thermometer at room temperature between 60.8° F -
Record the normal temperature of each family member here:
you know how the thermometer works and will feel more
Your ear is cold, wet or blocked with ear wax
You are suffering from an ear infection
DO NOT measure temperature if:
in water or any other liquid.
consult your physician.
The LifeSource ear thermometer utilizes infrared thermo scanning
Measurements can even be taken while your child is sleeping. For
temperature. Therefore, the ear is an accurate indicator of internal
eardrum is located beneath the surface and not easily influenced
The LifeSource ear thermometer is faster, safer and easier to use
times per second and displays the highest temperature detected.
principles to scan the temperature of the human eardrum. The
than traditional stick thermometers. It scans the eardrum 512
Research indicates that the ear is an ideal site for taking body
adults, an ear thermometer offers fast, comfortable, accurate
temperature. The eardrum shares blood vessels with the
hypothalamus, the part of the brain that controls body
by the changing temperature in the environment.
readings in seconds.
body temperature.


To switch between Fahrenheit and Celsius, follow these steps:
release the SCAN button. You can now switch between F°
is displayed. Follow steps #4-6 on page E-6.

seconds (the thermometer is performing multiple scanning
recommended you wait 5 seconds between measurements.
cleaned with an alcohol moistened cotton swab).
The thermometer will power on and will
the beep. Remove thermometer from ear
display. Thermometer is now ready for
measurement taken will appear on the
Insert the thermometer tip gently into
canal. The temperature is displayed.
thermometer will beep, the last
sequences within eardrum).
minute of non-use.
perform a self test.
measurement.
finished.
the ear.
and C°

A. The thermometer is not positioned properly in the ear. The tip of
is different. Also, the position of the thermometer can affect the
the thermometer must form a seal around the opening of the ear.
A. The waterproof lens is dirty. Clean the lens with a soft, alcohol
values may differ because the shape and cleanliness of each ear
specifically for the human ear construction and human body
human use. The UT-202 ear thermometer was programmed
A. The temperature is roughly the same in both ears, but the
A. No. This thermometer has been designed exclusively for
animal’s temperature?
moistened cotton swab.
temperature.
reading.
thermometer is waterproof). Clean the body of the thermometer
Do not expose the thermometer to extreme temperature, very high
humidity, direct sunlight, vibration or shock. After cleaning, place
Replace the battery when the ‘low battery’ warning symbol appears
Clean the lens of the thermometer with a soft, alcohol moistened
with a soft, dry cloth - DO NOT use water, cleaning solutions or
any other liquid. Never use an abrasive cleaner or submerge the
the thermometer in the protective case and store it at room
body of the thermometer in water or any other liquids.
cotton swab after each use (NOTE: only the tip of the
Replacing the Battery
from the battery lid.
on the display.
temperature.

A&D Medical until the returned item is received by A&D Medical.
Register your ear thermometer warranty online at
warranted to the original retail purchaser to be free from defects in
To make a warranty claim, return the Product, freight prepaid and
Medical. This warranty will not apply if the defect or malfunction
Product; or failure to follow the written instructions enclosed with
the Product. Responsibility for loss or damage does not transfer to
failures resulting from misuse, abuse, alteration of the LifeSource
UT-202 Ear Thermometer, use of improper components or failure
For returns in the USA, customers are asked to call A&D Medical
for appropriate shipping costs (customers in Canada are asked to
call Auto Control Medical at 1-800-463-5414). A&D Medical will
remainder of the initial warranty period, whichever is longer. All
persons not authorized by A&D Medical, misuse, abuse, damage
material and workmanship, under normal use, for a period of 2
insured (or assume the risk of loss or damage during shipment)
necessary to correct defects in material or workmanship covered
Products or parts that are replaced become the property of A&D
years from the date of purchase. This warranty does not cover
together with the proof of purchase (such as a sales receipt) to:
either repair, or at its option, replace free of charge, any parts
refurbished. A&D Medical warrants any replaced or repaired
A&D Medical Auto Control Medical Inc.
voltage; modification, alteration or repairs of the Product by
during transit or lack of reasonable care with respect to the
For USA residents For CANADA residents
by this limited warranty. Replacement parts may be new or
Your LifeSource UT-202 Ear Thermometer ("Product") is
product or part for sixty (60) days from shipment, or the
Milpitas, CA 95035 H9R 5P9 Canada
to comply with the operating instructions.
(36° C) or greater than 102.2° F (39° C)
Operating environment 60.8° F – 104.0° F (16° C - 40° C) with
102.2° F (36° C - 39° C) ± 0.5° F (0.3° C) : Less than 96.8° F
Thermometer tip Equipped with a waterproof lens. No
Automatic shut down The thermometer will automatically
turn off after one minute of non-use.
Power supply One 3 Volt CR-2032 Lithium battery
Battery life Approximately 5,000 measurements
Storage environment -4° F – 122° F (-20° C - 50° C) with
Measuring accuracy ± 0.4° F (0.2° C) : From 96.8° F to
Memory function Displays the last taken temperature
Measuring range 93.2° F – 109.4° F (34° C - 43° C)
Weight 1.2 oz. (36 g) including battery
relative humidity up to 95%
relative humidity up to 95%
Dimensions: 1.2 x 4.1” (3.0 x 11.8 cm)
Sensor type Thermopile Sensor ST118
lens cover is required.
when powered-on.
Display resolution 0.1° C or F
Response time 1.0 second
Model UT-202

If You Need Assistance with the Set-Up or Operation
Please call us FIRST before contacting your retailer at
A specially trained representative will assist you
1-800-463-5414 In Canada
LifeSource Health Line
We Can Help!
IMPORTANT!
Specifications subject to change without notice.
A division of A&D Engineering, Inc.
LifeSource is a trademark of A&D Medical.
©2003 A&D Medical. All rights reserved.
I-MAN:202 Printed in China 1/03
1555 McCandless Drive Milpitas, CA 95035
scientific and technological methods, and offer accurate, easy to use,
home monitoring and treatment options. The product line includes:
Check out these products on the web at www.LifeSourceOnline.com
This LifeSource product is covered by a 2 year Limited
For more information regarding use, care or servicing of your
Our products are designed and manufactured using the latest
Auto Control (Toll-Free): 1-800-463-5414
CONTACT INFORMATION
For Canadian Residents, please contact:
A division of A&D Engineering, Inc.
Warranty. See page E-11 for details.
Instant-Read Ear Thermometer, contact:
Digital Blood Pressure Monitors
Aneroid Blood Pressure Kits
1555 McCandless Drive Milpitas, CA 95035
Auto Control Medical
206A boul. Brunswick Pointe-Claire, Quebec
www.autocontrol.com
H9R 5P9 Canada
A&D Medical
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.