SWITCHING BETWEEN FAHRENHEIT & CELSIUS 1.Press and release the START button. 2. Wait for display to read --- °C / --- °F (approx. 5 seconds) . 3. Before °C/°F begins flashing, press the Start button for three seconds. 4. Unit will switch from °C/°F. 5. When °C/°F symbol begins to flash, the thermometer is ready to take your temperature.
CHANGING THE BATTERY When the “ M ” appears in the lower right of the display, the battery is exhausted and needs replacing. Make sure you use the same type of battery and proceed as follows: Remove battery cover. Use a small screwdriver or a straight pin to remove battery. Insert new equivalent battery type (1.5V, LR41). Ensure bat- tery is correctly positioned with the “+” facing up. Carefully replace the battery cover. Properly dispose of the battery, keeping it from small children and heat.
SAFETY INFORMATION ❑High, prolonged fever requires medical attention especially for young children. In case of high readings, please contact your physician. ❑Do not allow children to take their temperature unattended. ❑Read the enclosed instructions carefully to ensure accurate temperature readings. ❑Do not allow children to walk or run while taking temperature. The probe could present a hazard. ❑Use only the commercial disinfectants listed in this manual to clean the ther- mometer. The thermometer must be intact when immersed in liquid disinfectant. For more information, see the section Cleaning and Disinfecting. ❑Never boil the thermometer. ❑Avoid bending the thermometer tip more than 45˚. ❑Do not open the thermometer except to replace the battery. ❑Keep battery away from children.
Congratulations on your purchase of the LifeSource Flex-Tip Digital Thermometer. Please read the instructions carefully to ensure accurate temperatures and safe operation. When used properly, this high quality product will give you years of accurate, dependable service.
The thermometer is 100% waterproof and may be immersed in water or disinfectant solution for cleaning. It is recommended that you use one of the disinfectants listed below. Please follow the manufacturer’s instruc- tions when using the disinfectant.

Lysoformin 3000 Rosemann GmbH 6.0% Immerse for 24 hours
Gigasept FF Schike & 5.0% Immerse for Mayr GmbH 24 hours
Name of Manufacturer Dilution Max. duration disinfectant with water
WHAT IS A “NORMAL” TEMPERATURE? Temperature readings vary among individuals. A normal temperature refers to each individual’s average temperature while they are well. Normal average temperatures range from 97°F/36.1°C to 100°F/37.7°C when taken orally. Oral, underarm, and rectal temperatures vary by approximately 1°F (0.5°C). A rectal temperature is considered your real or “core” body tem- perature. A rectal temperature is 1°F/0.5°C higher than an oral reading and an underarm temperature is 1°F/0.5°C lower than an oral reading.
HOW TO CARE FOR THIS PRODUCT ❑Use of probe covers is recommended to help avoid spreading germs and to keep the thermometer clean. The thermometer should be cleaned after every use even when probe covers are used. ❑Clean the thermometer using isopropyl alcohol or soap and water. ❑Store the unit in the protective case while not in use. ❑Do not store or keep in direct sunlight, or in high temperatures. ❑Do not drop the thermometer, as this may damage the unit.
SPECIAL PRODUCT FEATURES ❑Reads temperature in Fahrenheit or Celsius. ❑Beeps when peak temperature is reached. ❑Convenient memory feature: automatic recall of last temperature reading. ❑100% waterproof. ❑Long-life, replaceable battery (approximately 1,500 temperatures). ❑Low battery indicator “ M ”. ❑Auto-Off in approximately 10 minutes. ❑Oral, rectal or underarm use. ❑Flexible tip for added comfort and safety. ❑Includes 5 free probe covers.
TO RECALL THE LAST TEMPERATURE
BEEPER: Beeps approximately 10 seconds after peak temperature is reached.
ACCURACY: ± 0.2°F between 96.0° and 104.2° F ± 0.1°C between 34.0° and 42.0° C At standard room temperature of 64° - 82.4° F (18.0° - 28° C)
HOW TO TAKE TEMPERATURE 1. Place a probe cover carefully over the tip (see figure on right). Select oral, underarm or rectal as your measurement site (see following instructions).
WARRANTY A&D Medical warrants to the first retail purchaser that this digital ther- mometer is free from defects in material and workmanship for the life- time of the original owner. This warranty does not cover batteries or damage resulting from improper handling or use. To obtain replacement product, please return the product, freight and insurance pre-paid, together with proof of purchase and applicable shipping costs to A&D Medical at the address below. Canadian residents can return the product to Auto Control Medical. Call us toll-free at 1-888-726-9966 for shipping costs and further information (in Canada, call 1-800-463-5414). At A&D Medical’s option, the product will be replaced with a new or refurbished product of equal value. THE WARRANTY AND REMEDY PROVIDED ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. Some states may have laws which amend this warranty.
In United States: In Canada: A&D Medical Auto Control Medical, Inc. A division of A&D Engineering 6695 Millcreek Drive, Unit 5 1555 McCandless Drive Mississauga, Ontario Milpitas, CA 95035 L5N 5R8 Toll-free LifeSource Health Line 1-888-726-9966 1-800-463-5414 www.LifeSourceOnline.com www.autocontrol.com
PRECAUTIONS ❑Do not drop unit or subject to shock. ❑Do not boil the probe. Clean the probe with isopropyl alcohol. ❑Do not use solvents or thinners on the unit. ❑Do not store the unit in direct sunlight or at high temperature. ❑Do not attempt to disassemble the unit except to replace the battery.
rectum. Do not force the tip into the rectum if resistance is encountered. ❑Dispose of the used probe cover and wash the thermometer as recommended. ❑Approximate measuring time is 30 seconds.
RECTAL USE ❑Commonly used for babies, young children or when it is difficult to take an oral or underarm temperature. ❑After placing the probe cover on the thermometer, lubricate with a water-soluble lubricant. ❑Gently insert the probe tip no more than 1/2 inch or 1.3cm into the
UNDERARM (AXILLARY) USE ❑From a medical point of view, this method will always give an inaccurate reading and should not be used if a precise measurement is required. ❑Wipe underarm with a dry towel. ❑Place probe tip in armpit and bring arm down against the body. The probe should be pointing upward parallel to the arm. ❑Approximate measuring time is 30 seconds or longer depending on placement of the probe and closure of the arm against the body.
ORAL USE ❑Do not drink hot or cold fluids, exercise, smoke, or perform other activities that raise or lower temperature readings. ❑Place the probe tip well under the tongue as indicated by the ✔(see figure on right). The mouth should remain closed up to 5 minutes before taking a reading. Instruct children not to bite down on the thermometer. ❑Approximate measuring time is 30 seconds. Opening of mouth or improper placement of the probe tip can result in longer read time.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.