APOLLO AE-SERIES ELECTRIC ACTUATORS

General Installation, Operation, Specifications, Maintenance and Trouble Shooting Instructions

The following is intended as a guide only in installing and operating the electric actuator. The manufacturer assumes no liability whatsoever for any personal injury or other special or consequential damages that may occur. There are no warranties as to suitability for a specific application or purpose.

Installation / Mechanical Operation

  • Verify that the valve breakaway torque is less than the rated output torque of the actuator.
  • Any mechanical stops that would interfere with the operation of the actuator must be removed before installation of the actuator, i.e. lever, travel stops, etc.
  • The actuator output coupling must be centered with the valve stem to prevent side loading, which causes premature stem packing wear.
  • The AE-Series actuator is not recommended for actuation of butterfly valves or other similar resilient seated valves, unless installed with Motor Break option.
  • To use the manual override feature (identified on cover label), the override shaft must be pressed down firmly at least 1/4” in order to disengage the motor from the gears. The manual override is not designed to overcome torque in excess of the rated torque of the actuator. Serious damage to the gear system may result from excessive turning force on the manual override.
  • The AE-Series actuator may be mounted in any position, i.e. horizontal, upside down. If the conduit entrance points upward, conduit piping must be oriented as to prevent condensation from entering the actuator from the conduit pipe.
  • Always verify that the supply voltage and required voltage are the same.
  • AE-series 24VAC, 115VAC and 230VAC actuators use capacitor run-reverse induction motors, which create higher feedback voltages that the supply voltage. Control devices connected to terminals 3 and 4 must be rated for 250VAC minimum for 15VAC actuators, (440VAC min. for 230VAC actuators: 125VAC min. for 24VAC).
  • Do not wire actuators in series or parallel with another actuator or other electrical equipment due to the induction feedback voltage created by the motor.
  • Separate (isolated contacts) are required for each actuator.
  • When wiring DC voltage actuators, verify that terminal polarity is correct (pos.+ & Neg.-). Failure to do so will cause the actuator to operate out of its normal 90 degree rotation.
  • The AE-Series actuators are designed to operate at 25% duty cycle at temperatures below 100°F. This means that for a cycle time of 25 seconds the actuator must rest for 75 seconds. This is an average. For example: The actuator may cycle several times in a row, but must rest for a period 75% longer that the time it operated.
  • All models require electrical power to both OPEN and to CLOSE the actuator and valve.

Under normal circumstances the actuator will not require additional lubrication. All of the actuator’s essential components are permanently lubricated at the factory.

  • Seal conduit entrances to prevent water or dirt from entering the housing. Excessive moisture can cause premature wear or corrosion within the housing.
  • Periodically inspect actuator and valve assembly for worn parts, loose fasteners, or damage to the outside of the unit. General Specifications

Electrical Operation · Maintenance

Page 2 of the Apollo Gate Opener (AE-Series) user manual — AE-SERIES NUMBERING SYSTEM
Page 2 · click to enlarge
Page 2
Apollo Gate Opener (AE-Series) — AE-SERIES NUMBERING SYSTEM diagram (page 2)
Fig. 1
Actuator ModelBreakaway Torque Output (in.-lbs.)Cycle Time 90° Travel (50% Load)Duty Cycle*Amperage Draw (max.) Starting or locked rotor current voltage 24 VAC115VAC230VAC12VDC24VDC AE200200 in-lbs.5.0 sec.25%4.56 amp.74 amp.44 amp2.00 amp1.38 amp AE400400 in-lbs.10.0 sec.25%4.56 amp.74 amp.44 amp2.00 amp1.38 amp AE600600 in-lbs.15.0 sec.25%4.56 amp.74 amp.44 amp2.00 amp1.38 amp AE800800 in-lbs.20.0 sec.25%4.56 amp.74 amp.44 amp2.00 amp1.38 amp AE10001000 in-lbs.25.0 sec.25%4.56 amp.74 amp.44 amp2.00 amp1.38 amp
MotorAC models: 24 VAC, 120 VAC or 230 VAC, Reversible. 3 wire, capacitor run. Self-resetting thermal overload protection, Class B insulation, sub-fractional horsepower. DC models: 12 VDC or 24 VDC, Reversible. 2 wire, POS. & NEG. No thermal overload (external circuit breaker or fuse suggested for protection). LubricationPermanently lubricated gear train and bearings. Duty CycleThe AE-Series actuators are designed to operate at 25% duty cycle at temperatures below 100°F. See Electrical Operation. Temperature Operating Range32°F to 150°F standard -40°F to 150°F with optional heater & thermostat Thermal ProtectionSelf-resetting (AC Motors Only) Conduit Connections(2) 1/2”-NPT female Direction Of TravelClockwise to Close, Counterclockwise to Open (Position indicator shaft only, manual override shaft rotates opposite)

AE-SERIES NUMBERING SYSTEM

Constant Torque Voltage Options 200 1 = 115 vac 0 = Standard 400 2 = 24 vac A = One extra switch & cams 600 3 = 220 vac B = Two extra switches & cams 800 4 = 12 vac C = Three extra switches & cams 1000 5 = 24 vac D = Heater & Thermostat E = Single Potentiometer Enter all digits of Torque value

F = Motor Break

Page 3 of the Apollo Gate Opener (AE-Series) user manual — (CUSTOMER SUPPLIED). 115 VAC LINE VOLTAGE
Page 3 · click to enlarge
Page 3

24/115/230 VAC Wiring Diagram

Apollo Gate Opener (AE-Series) — (CUSTOMER SUPPLIED). 115 VAC LINE VOLTAGE diagram (page 3)
Fig. 2

SUGGESTED CONTROL WIRING (CUSTOMER SUPPLIED). POSITIION INDICATOR JUNCTION 1-2 AND 1-5.

(CUSTOMER SUPPLIED). 115 VAC LINE VOLTAGE

CLOSED POSITION SWITCH (TOP)

Page 4 of the Apollo Gate Opener (AE-Series) user manual — OPTIONAL 15 WATT 115 VAC HEATER & THERMOSTAT
Page 4 · click to enlarge
Page 4

OPEN POSITION SWITCH (BOTTOM)

OPTIONAL MOTOR RREAK

TERMINALS 6-12 ARE USED FOR OPTIONAL LIMIT SWITCHES OR HEATER & THERMOSTAT

OPTIONAL 15 WATT 115 VAC HEATER & THERMOSTAT

LINE VOLTAGEW1W2F1 OPTIONAL 24 VAC 60 HZ 1 PHREDBLUE5 AMP 115 VAC 60 HZ 1 PHREDBLUE1 AMP 230 VAC 60 HZ 1 PHYELLOWBLUE.75 AMP

DUE TO HIGH AC INDUCTION FEEDBACK VOLTAGE THROUGH THE CAPACITOR AND TERMINALS 3 & 4, MULTIPLE ACTUATORS CANNOT BE WIRED IN PARALLEL. SEPARATE RELAYS (ISOLATED CONTACTS) MUST BE PROVIDED FOR EACH ACTUATOR. DEVICES CONNECTED TO TERMINALS 3 & 4 MUST BE RATED FOR 250 VAC OR (440 VAC FOR 230 VAC OPERATION VOLTAGE).

Page 5 of the Apollo Gate Opener (AE-Series) user manual — SUGGESTED CONTROL WIRING (CUSTOMER SUPPLIED)
Page 5 · click to enlarge
Page 5

12/24 VDC WIRING DIAGRAM

Apollo Gate Opener (AE-Series) — 12/24 VDC WIRING DIAGRAM diagram (page 5)
Fig. 3

ON-OF-ON DPDT SW.

SUGGESTED CONTROL WIRING (CUSTOMER SUPPLIED)

(CUSTOMER SUPPLIED). 115 VAC LINE VOLTAGE

Page 6 of the Apollo Gate Opener (AE-Series) user manual — .748 SQUARE .747 X .87 DEEP
Page 6 · click to enlarge
Page 6

CLOSED POSITION SWITCH (TOP)

RED +TERM MOTOR – TERM BLACK

OPEN POSITION SWITCH (BOTTOM)

TERMINALS 6-12 ARE USED FOR OPTIONAL LIMIT SWITCHES OR HEATER & THERMOSTAT

OPTIONAL 15 WATT 115 VAC HEATER & THERMOSTAT

LINE VOLTAGEW1W2F1 OPTIONAL 12 VDCORANGEBLUE3 AMP 24 VDCBROWNBLUE1.5 AMP

MANUAL OVERRIDE SHAFT .312 SQUARE

CPTIVE SCREWS ARE 1/4” – 20 UNC SOCKET HEAD CAP SCREWS, 6 PLACES

INDICATOR – SHOWN IN CLOSED POSITION

1/2” NPT, TYPICAL BOTH SIDES

3.5” CLEARANCE (FROM TOP OF OVERRIDE SHAFT) REQUIRED FOR COVER REMOVAL

5/16-18 UNC X .62 DEEP 4 PLACES TYPICAL

02.756 B.C.

.748 SQUARE .747 X .87 DEEP

1.949 SQUARE

MOUNTING PATTERN ISO 5211 – F07

Page 7 of the Apollo Gate Opener (AE-Series) user manual — AE-SERIES DIMENSIONS
Page 7 · click to enlarge
Page 7

AE-SERIES DIMENSIONS

Apollo Gate Opener (AE-Series) — AE-SERIES DIMENSIONS diagram (page 7)
Fig. 4
Apollo Gate Opener (AE-Series) — AE-SERIES DIMENSIONS diagram (page 7)
Fig. 5
Page 8 of the Apollo Gate Opener (AE-Series) user manual — AE-SERIES DIMENSIONS
Page 8 · click to enlarge
Page 8
Apollo Gate Opener (AE-Series) — AE-SERIES DIMENSIONS diagram (page 8)
Fig. 6
Apollo Gate Opener (AE-Series) — AE-SERIES DIMENSIONS diagram (page 8)
Fig. 7

Ask about the Apollo Gate Opener (AE-Series)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Apollo Gate Opener (AE-Series)

Be the first to ask — other owners or our team will answer.

Original document

Apollo Gate Opener (AE-Series) manual PDF

8 pages·474 KB·Automobile Parts·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…