RW1700-030APO REACH XP95 Loop Interface Module

QUICK START GUIDE

Apollo REACH XP95 Loop Interface Module (RW1700-030APO) — RW1700-030APO REACH XP95 Loop Interface Module diagram (page 1)
Fig. 1 · RW1700-030APO REACH XP95 Loop Interface Module

THE BOX

INSIDE THE BOX

MOUNTING STEPS

Product Part Number Product Description

  • 1 x Loop Interface Module
  • 4 x Screws
  • 1 x Quick start guide

The Translator Module is IP65 rated, suitable for external mounting. The back box must be installed on the wall as flat as possible to retain IP rating, to prevent distortion of the housing and the ingress of contamination and/or moisture.

Proceed as follows to complete the device installation.

RW1700-030APO REACH XP95 Loop Interface Module

1 Remove top and bottom front plastics that cover screws, unscrew all four screws and remove the lid from the back box.2 SCREWS Remove the electronic PCB assembly from the enclosure. The PCB is held by two Philips screws below the display, it then slides up and out. 3 MOUTING HOLES Using a suitable-sized drill bit (4mm) drill the pre-defined screw mounting points in the 4 corners of the backbox.YES 4 NO Prepare apertures (20mm knockouts) required for cable access and fit appropriate rated glands. 5 Screw the back box to the wall using all fixing holes and appropriate-sized roundhead screws (do not use countersunk screws).6 SCREWS HOLES Insert cable, tighten glands and refit PCB and securing screws.
Apollo REACH XP95 Loop Interface Module (RW1700-030APO) — THE BOX diagram (page 1)
Fig. 2

IMPORTANT TO CONSIDER

When mounting a wireless device a comprehensive radio survey should have been carried out to establish the location that provides the best coverage and optimum reach. Taking into consideration the building structure and materials, the survey identifies the wireless infrastructure required and product locations for optimum performance, identifying any factor that could prevent radio integrity.

  • Avoid fixing or mounting the unit close to the following:
  • Equipment that utilises large electrical currents
  • Large metal objects or structures
  • Fluorescent lighting fittings
  • Metal ceiling structures
  • IT cabling.

Keep 2 meters minimum spacing between other wireless equipment in the area to avoid signal interference.

EN54 approved environmental temperature range is -10°C to +55°C

Apollo REACH XP95 Loop Interface Module (RW1700-030APO) — IMPORTANT TO CONSIDER diagram (page 1)
Fig. 3

UNBOXING

scan QR for full product manual

Apollo REACH XP95 Loop Interface Module (RW1700-030APO) — UNBOXING diagram (page 1)
Fig. 4
  • The Translator has removable top and bottom front plastics to cover screw housings.
  • The Translator is housed in an IP Rated box, with knockouts for IP rated glands.
  • 4 plastic screws are provided to secure the lid.

For more information, please refer to the user manual

RW1700-030APO

Apollo Fire Detectors Ltd. 36 Brookside Road, Havant, Hampshire, United Kingdom, PO9 1JR T: +44 (0)23 9244 2706 - E: techsales@apollo-fire.com - W: www.apollo-fire.co.uk

RW_IG_LOOP_INTERFACE_REV_A.2

Page 2 of the Apollo REACH XP95 Loop Interface Module (RW1700-030APO) user manual — RW_IG_LOOP_INTERFACE_REV_A.2
Page 2 · click to enlarge
Page 2

RW1700-030APO REACH XP95 Loop Interface Module

QUICK START GUIDE

LOOP OUT (-)

SCREEN LOOP IN (+)

LOOP IN (-)

LOOP OUT (+)

SCREEN

Apollo REACH XP95 Loop Interface Module (RW1700-030APO) — LOOP OUT (-) diagram (page 2)
Fig. 5

GREEN LED

  • The translator will power up and the translator will be

ready for commissioning phase.

  • The Loop connector on the top of the translator board should be wired to the Panel of your choice, from the left to right the terminals are:
  • Loop Out Positive wired to Loop In Positive on the Panel
  • Loop Out Negative wired to Loop In Negative on the Panel
  • Screen
  • Follow the step by step instructions on the screen to complete the system setup.
  • Loop In Positive wired to loop Out Positive on the Panel
  • Loop In Negative wired to Loop Out Negative on the Panel
  • Screen
  • Screw the lid to the back box using the supplied plastic screws and refit top and bottom front plastics that cover screw housings.

Apollo Fire Detectors Ltd. 36 Brookside Road, Havant, Hampshire, United Kingdom, PO9 1JR T: +44 (0)23 9244 2706 - E: techsales@apollo-fire.com - W: www.apollo-fire.co.uk

RW_IG_LOOP_INTERFACE_REV_A.2

Ask about the Apollo REACH XP95 Loop Interface Module (RW1700-030APO)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Apollo REACH XP95 Loop Interface Module (RW1700-030APO)

Be the first to ask — other owners or our team will answer.

Original document

Apollo REACH XP95 Loop Interface Module (RW1700-030APO) manual PDF

2 pages·1.1 MB·Communications·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…