EN
Apollo logo
Official user manual

Apollo Commercial Clothes Dryer (150 III)

167 pages·2.2 MB·Personal Computer·PDF·ENDEFRITNLJA
Apollo Commercial Clothes Dryer (150 III)
Table of Contents 80 sections 12.1”/15.0”/15.1” TFT Intel ® Celeron/Pentium ® III · Plastic-housing Panel PC with Versatile Stand design · User’s Manual (Version 2305) · Copyright Notice · … ShowHide
12.1”/15.0”/15.1” TFT Intel ® Celeron/Pentium ® IIIp.1Plastic-housing Panel PC with Versatile Stand designp.1User’s Manual (Version 2305)p.1Copyright Noticep.2Trademarksp.2Unpackingp.3Warrantyp.3Important Safety Precautionsp.44. I/O CONNECTION........................................ 4-29p.75. HARDWARE INSTALLATION AND UPGRADE . 5-51p.86. SYSTEM MOTHERBOARD & I/O BOARD........ 6-77p.87. AWARD BIOS SETUP.................................. 7-105p.108. SOFTWARE & DRIVERS INSTALLATION ..... 8-141p.101. I NTRODUCTIONp.111.1. General Informationp.121.2. What Covers in this Manualp.131.3. Specificationsp.15SYSTEMp.15PERIPHERAL & STORATE DEVICESp.18MECHANICAL & ENVIRONMENTALp.191.4. Dimensionsp.201.4.1. APOLLO 120p.201.4.2. APOLLO 150p.212. U SING THE S YSTEMp.232.1. Identifying the Systemp.242.1.1. Front Viewp.242.1.2. Side Viewsp.25CD-ROMp.252.1.3. I/O Outletsp.26J K L M N O Pp.26P . USB*2p.262.2. System Setup for the First-time Usep.272.2.1. Installation Proceduresp.272.2.2. Running the BIOS Setupp.282.2.3. Operating System and Driver Installationp.293. V ERSATILE STANDING & MOUNTING OPTIONSp.313.1. Versatile Standp.323.1.1. Standing Uprightp.323.1.2. 45 to 90 0 Free Standingp.323.1.3. Fixed Standingp.333.1.4. Cable Managementp.343.2. Wall Mounting and Mobile Applicationsp.35F IGURE 3-6 F IGURE 3-7p.363.3. Panel Mountingp.373.4. KIOSK Integrationp.38HERCULES Tp.38HERCULES Mp.38HERCULES PKp.38HERCULES Pp.38HERCULES Kp.384. I/O C ONNECTIONp.394.2. COM Ports x 4p.414.3. 100/10 Base-T Ethernet (RJ-45)p.43RJ-45p.434.5. 2 nd Display Graphic Support Modep.444.5.1. When System Memory Clock = 66MHzp.444.5.2. When System Memory Clock = 100MHzp.484.5.3. When System Memory Clock = 133MHzp.514.6. PS/2 Keyboard Interfacep.554.7. PS/2 Mouse Interfacep.554.8. External FDD (DB-15)p.564.9. +5V/12V DC-Outp.574.11. DIO (Digital Input & Output)p.58DIO1 RJ11p.5874LS244p.5874LS273p.58DIO1p.58RJ11p.584.12. Audio Interface (Line-in, MIC-in, SPK-out)p.604.14. IR Keyboard Sensor (optional)p.605. HARDWARE INSTALLATION AND UPGRADEp.615.1. Recognizing the System Major Partsp.63F IGURE 5-1: APOLLO 120 EXPLODED DIAGRAMp.635.2. Installing the CPUp.65F IGURE 5-3p.655.3. Installing the SDRAM Memory Modulep.665.4. Motherboard Assemblyp.675.5. Touch Controller Assemblyp.685.6. HDD Module Assemblyp.69F IGURE 5-4: HDD INSTALLATIONp.69
Page 1 of the Apollo Commercial Clothes Dryer (150 III) user manual — 12.1”/15.0”/15.1” TFT Intel ® Celeron/Pentium ® III
Page 1 · click to enlarge
Page 1

12.1”/15.0”/15.1” TFT Intel ® Celeron/Pentium ® III

Plastic-housing Panel PC with Versatile Stand design

User’s Manual (Version 2305)

Apollo Commercial Clothes Dryer (150 III) — 12.1”/15.0”/15.1” TFT Intel ® Celeron/Pentium ® III diagram (page 1)
Fig. 1 · 12.1”/15.0”/15.1” TFT Intel ® Celeron/Pentium ® III
Page 2 of the Apollo Commercial Clothes Dryer (150 III) user manual — Trademarks
Page 2 · click to enlarge
Page 2

Copyright Notice

This document is copyrighted 2003 by the Manufacturer. The information provided in this document has been carefully checked and is accurate at the time of publication. However, the Manufacturer assumes no responsibility for any infringements of patents or other rights of third parties that may result from its use. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form of or via any means without the prior written permission of the Manufacturer. Further, this publication and features described herein are subject to change without notice.

Trademarks

All brand and product names used for identification in this document are trademarks or registered trademarks of their respective companies.

© Copyright 2003, May Version 2305 All rights reserved. Printed in Taiwan

Page 3 of the Apollo Commercial Clothes Dryer (150 III) user manual — Warranty
Page 3 · click to enlarge
Page 3

Unpacking

After unpacking the APOLLO 120/150 III carton, check and see if the following items are included and in good condition.

u APOLLO III main system x 1 u Accessories - Power cord (90o) x 1 - External FDD cable (optional) x 1 - External 5V/12V DC power cable (optional) x 1 - Utilities & drivers & user manual CD diskette x 1 (for touchscreen drivers, please download the updated drivers from the following website http://www.3m.com or http://www.elotouch.com or http://www.eturbotouch.com - Base knob with rubber cushion x 1 - Panel mounting kit (optional) x 1 set

Make sure that all of the items listed above are present. If any of the above items is missing, contact your dealer immediately.

Warranty

All products manufactured by the Manufacturer. are warranted against defective materials and workmanship for one year starting from the date of delivery to the original purchaser. However, warranty or service will not be extended if 1). the product is repaired, modified or altered unless such repair, modification or alteration is authorized by the Manufacturer; or 2). the product serial number or warranty label is defaced or missing; or 3). the product is not properly used.

Page 4 of the Apollo Commercial Clothes Dryer (150 III) user manual — Important Safety Precautions
Page 4 · click to enlarge
Page 4

Important Safety Precautions

Before getting started, read these instructions and save them for later reference.

1. Turn off the computer before cleaning. Clean with a damp or dry cloth only. Do not spray any liquid cleaner on screen directly. 2. The power outlet socket used to plug in the computer power cord must be located near the system and easily accessible. Do not use outlets on the same circuit of the systems that regularly switched on and off. 3. Make sure the voltage of the power source is correct before connecting the computer to the power outlet.

4. If the computer is sharing an extension cord with other devices, make sure the total ampere rating of the devices plugged into the extension cord does not exceed the cord ’ s ampere rating.
5. Do not expose the power cord, extension cord and power outlet to moisture.
6. Install the computer on a reliable surface to prevent damage caused by dropping.
7. This computer is not equipped with an operating system. An operating system must be loaded first before installing any software into the computer.
8. Disconnect the power cord from the computer before any installation. Make sure both the computer and the external devices are turned off. The sudden surge of power may ruin any sensitive components. Also make sure the computer is properly grounded.
9. During installation of any internal components, be sure to ground yourself to keep from any static charge. Most electronic components are sensitive to the static electric charge. Use a grounding wrist strap and place all electronic components in any static-shielded devices.
Page 5 of the Apollo Commercial Clothes Dryer (150 III) user manual — Important Safety Precautions
Page 5 · click to enlarge
Page 5
10. The openings on the computer enclosure are for the cabin ventilation to prevent the computer from overheating. DO NOT COVER THE OPENINGS.
11. The brightness of the flat panel display will decrease with use. However, hours of use will vary depending on the application environment.
12. If the computer is equipped with a touch panel, avoid using sharp objects to operate the touch panel. Scratches on the touch panel may cause mal-calibration or non-function to the panel.
13. The LCD panel display is not subject to shock or vibration. When assembling the computer, make sure it is securely installed.
Page 6 of the Apollo Commercial Clothes Dryer (150 III) user manual — Important Safety Precautions
Page 6 · click to enlarge
Page 6
Page 6 of the Apollo Commercial Clothes Dryer (150 III) user manual — Important Safety Precautions
Page 7 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4. I/O CONNECTION........................................ 4-29
Page 7 · click to enlarge
Page 7

4. I/O CONNECTION 4-29

4.1. PARALLEL PORT 4-30 4.2. COM PORTS X 4 4-31 4.3. 100/10 BASE-T ETHERNET (RJ-45) 4-33 4.4. VGA INTERFACE 4-33 4.5. 2 ND DISPLAY GRAPHIC SUPPORT MODE 4-34 4.5.1. When System Memory Clock = 66MHz 4-34 4.5.1.1. Single Display Mode 4-35 4.5.1.2. Mirror Display Output Mode 4-36 4.5.1.3. Multiple Display Output Mode 4-37 4.5.2. When System Memory Clock = 100MHz ..4-38 4.5.2.1. Single Display Mode 4-38 4.5.2.2. Mirror Display Output Mode 4-39 4.5.2.3. Multiple Display Output Mode 4-40 4.5.3. When System Memory Clock = 133MHz ..4-41 4.5.3.1. Single Display Mode 4-42 4.5.3.2. Mirror Display Output Mode 4-43 4.5.3.3. Multiple Display Output Mode 4-44 4.6. PS/2 KEYBOARD INTERFACE 4-45 4.7. PS/2 MOUSE INTERFACE 4-45 4.8. EXTERNAL FDD (DB-15) 4-46 4.9. +5V/12V DC-OUT 4-47 4.10. VR BRIGHTNESS CONTROL 4-47 4.11. DIO (DIGITAL INPUT & OUTPUT) 4-48 4.12. AUDIO INTERFACE (LINE-IN, MIC-IN, SPK-OUT) .4-50 4.13. USB PORTS 4-50 4.14. IR KEYBOARD SENSOR (OPTIONAL) 4-50 4.15. AC/DC INLET/POWER SWITCH 4-50

Page 8 of the Apollo Commercial Clothes Dryer (150 III) user manual — 6. SYSTEM MOTHERBOARD & I/O BOARD........ 6-77
Page 8 · click to enlarge
Page 8

5. HARDWARE INSTALLATION AND UPGRADE . 5-51

5.1. RECOGNIZING THE SYSTEM MAJOR PARTS 5-53 5.2. INSTALLING THE CPU 5-55 5.3. INSTALLING THE SDRAM MEMORY MODULE 5-56 5.4. MOTHERBOARD ASSEMBLY 5-57 5.5. TOUCH CONTROLLER ASSEMBLY 5-58 5.6. HDD MODULE ASSEMBLY 5-59 5.7. TOUCHSCREEN OR FRONT BEZEL ASSEMBLY 5-60 5.8. LCD MODULE ASSEMBLY 5-62 5.9. CD-ROM/DVD-ROM/FDD MODULE ASSEMBLY ..5-67 5.9.1. Internal CD-ROM/FDD Assembly 5-67 5.9.2. External FDD Connection 5-69 5.10. POWER MODULE ASSEMBLY 5-70 5.11. EXPANSION OUTLETS & RISER CARD ASSEMBLY 5-72 5.12. BACK PANEL ASSEMBLY 5-73 5.13. STAND MODULE ASSEMBLY 5-74

6. SYSTEM MOTHERBOARD & I/O BOARD 6-77

6.1. APOLLO III MOTHERBOARD 6-78 6.1.1. General Information 6-78 6.1.2. Specifications 6-79 6.1.3. Locating Jumpers & Connectors 6-81 6.1.4. Jumpers & Jumper Setting 6-82 6.1.4.1. DOC 2000 Address Setting (JP1) 6-83 6.1.4.2. Clear CMOS (JP2) 6-83 6.1.4.3. COM 2 232/422/485 Setting 6-83

Page 9 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5. HARDWARE INSTALLATION AND UPGRADE . 5-51
Page 9 · click to enlarge
Page 9

6.1.5. Connectors & Pin Assignment 6-84 6.1.5.1. PWR3: ATX Power connector 6-85 6.1.5.2. J2: CD Audio IN 6-86 6.1.5.3. J7: HDD LED & ACPI LED & SMI 6-86 6.1.5.4. J8: IR / CIR Connector 6-86 6.1.5.5. J9: Power LED & KB 6-87 6.1.5.6. SW1: ATX Power ON/OFF & Reset 6-87 6.1.5.7. COM3 6-87 6.1.5.8. LCD1: LCD Connector 6-88 6.1.5.9. INV1: LCD Inverter Connector 6-89 6.1.5.10. FDD1: FDD connector 6-89 6.1.5.11. IDE1/IDE2: Primary/Secondary HDD.6-90 6.1.5.12. SCSI 1: PRT/Serial Port/DIO Port 6-91 6.1.5.13. SCSI 2: KB/MS/VGA/LAN USB/FDD...6-92 6.1.5.14. CN4: PCI/ISA Expansion Slot 6-93 6.2. APOLLO III I/O BOARD 6-96 6.2.1. Locating Jumpers & Connectors 6-96 6.2.2. Jumpers & Jumper Setting 6-97 6.2.2.1. JP1: Keyboard Power Select 6-97 6.2.2.2. COM port Power Selection 6-97 6.2.3. Connectors & Pin Assignment 6-98 6.2.3.1. KB1: PS/2 Keyboard Connector 6-99 6.2.3.2. KBMS: PS/2 Mouse 6-99 6.2.3.3. COM1, COM2, COM4: DB-9 6-99 6.2.3.4. CN1: DC Power Output 6-100 6.2.3.5. LPT1: D-SUB-25 Parallel Port 6-100 6.2.3.6. CRT1: VGA (D-SUB 15 Pin) 6-100 6.2.3.7. FDD1: External FDD Connector 6-101 6.2.3.8. J11: USB 1 , USB2 Connector 6-101 6.2.3.9. DIO1: RJ-11 Connector 6-101 6.2.3.10. LAN1: RJ-45 Ethernet Connector 6-101 6.2.3.11. MIC1 6-102 6.2.3.12. LINE 1 6-102 6.2.3.13. SPK 1 6-102 6.2.3.14. SCSI 1: PRT /Serial Port/DIO Port ... 6-103 6.2.3.15. SCSI 2: KB/MS/VGA/LAN USB/FDD. 6-104

Page 10 of the Apollo Commercial Clothes Dryer (150 III) user manual — 8. SOFTWARE & DRIVERS INSTALLATION ..... 8-141
Page 10 · click to enlarge
Page 10

7. AWARD BIOS SETUP 7-105

7.1. AWARD BIOS 7-106 7.2. CONTROL KEY DEFINITION 7-107 7.3. GETTING HELP 7-108 7.3.1. Main Menu 7-108 7.4. AWARD BIOS SETUP 7-108 7.4.1. AWARD BIOS Setup Main Menu 7-108 7.4.2. Standard CMOS Features 7-110 7.4.3. Advanced BIOS Features 7-113 7.4.4. Advanced Chipset Features 7-117 7.4.5. Integrated Peripherals 7-123 7.4.6. Power Management Setup 7-127 7.4.7. PnP/PCI Configuration 7-131 7.4.8. PC Health Status 7-133 7.4.9. Frequency Voltage Control 7-134 7.4.10. Load Fail-Safe Defaults 7-136 7.4.11. Load Optimized Defaults 7-137 7.4.12. User Password 7-138 7.4.13. Save and Exit Setup 7-139 7.4.14. Exit Without Saving 7-140

8. SOFTWARE & DRIVERS INSTALLATION 8-141

8.1. ETHERNET DRIVERS 8-142 8.2. PC 610 AGP XGA 8-143 8.3. AUDIO SETUP 8-144 8.4. TOUCHSCREEN DRIVERS 8-145 8.5. DRIVER INSTALLATION 8-146 APPENDIX 8-147 A: LCD SPECIFICATION 8-147 B: DISKONCHIP INSTALLATION 8-150 C: WAKE-ON-LAN 8-152 D: FIRST MB MEMORY MAP 8-155 E: POWER SUPPLY 8-156

Page 11 of the Apollo Commercial Clothes Dryer (150 III) user manual — 1. I NTRODUCTION
Page 11 · click to enlarge
Page 11

1. I NTRODUCTION

This chapter provides background information and detail specification on the APOLLO 120/150 III. Sections in this chapter include: u General Information

u What covers in this Manual u Specification u Dimension

Page 12 of the Apollo Commercial Clothes Dryer (150 III) user manual — 1.1. General Information
Page 12 · click to enlarge
Page 12

1.1. General Information

The information revolution which started from the mid ’90 inaugurated a new competitive era where consumer- computing technology was exploited to business operation quicker than ever before. Many enterprises from our life related industries such as POS, POI, KIOSK, Banking, Medical to the high-tech Telecom, Aerospace, Semiconductor … etc. all are eager or forced to automate their industries with PCs in order to thrive in this new age. For their industrial automation, there is one thing in common, i.e. space is always a premium and system stability is always a must in their environmental applications. The APOLLO 120/150 is a 12.1"/15.0” or 15.1" TFT Intel Celeron/Pentium III/Pentium IV plastic-housing multimedia panel PC system. With a 150W or 200W ATX power supply as its engine, the APOLLO is a genuine P4 panel PC designed for high performance multimedia application. Featuring with versatile stand design for different environmental applications, the APOLLO itself can be used as a ready-to-play system by connecting to necessary peripherals. By integrating the APOLLO system to the special designed HERCULUS KIOSK, the complete system is widely used for KIOSK integration. It also provides 2 sets of VESA holes for market-available swing arms for mobile application. Also with the availability of both AC and DC systems, the APOLLO is the best turnkey solution platform for any system integration.

In terms of panel size, the APOLLO has 12.1” and 15.0” or 15.1” systems. In terms of system engine, the APOLLO also have two versions, one APOLLO III, Celeron/Pentium III system and the other APOLLO IV, Pentium IV system. To upgrade the system, simply replace the motherboard. Fully configurable and with its sleek outlook, the APOLLO is an ideal platform for any space-constricted application.

Page 13 of the Apollo Commercial Clothes Dryer (150 III) user manual — 1.2. What Covers in this Manual
Page 13 · click to enlarge
Page 13

1.2. What Covers in this Manual

This handbook contains most information you need to set up and use the APOLLO III system. You do not need to read everything in this handbook to use the system. For a quick start, see the following chapter summaries;

Chapter 1 (the current chapter) provides background

information and detail specification on the APOLLO 120/150 III.

Chapter 2 identifies the APOLLO III system exterior

components and provides instructions to help you to use the system as soon as possible. Chapter 3 details the panel PC’s various standing and

mounting options by graphical illustrations. Chapter 4 provides the procedures to connect external

devices to the I/O interface

Chapter 5 helps you to recognize the APOLLO system

internal components. It also provides the installation procedures including LCD, touchscreen, power supply module, CPU, system memory, FDD, HDD and CD-ROM drive.

Chapter 6 provides detail information of the jumper settings

and connector signals of the system control board.

Chapter 7 explains the AWARD BIOS setup. Chapter 8 introduces the Ethernet, XGA and audio drivers. Chapter 9 details the procedures to install the touchscreen

software drivers under DOS and Windows operation

Page 14 of the Apollo Commercial Clothes Dryer (150 III) user manual — 1.2. What Covers in this Manual
Page 14 · click to enlarge
Page 14

Appendix A details the 12.1”/15.0” or 15.1” LCD

specifications. Appendix B introduces the DiskOnChip installation.

Appendix C introduces the Wake-On-LAN feature. Appendix D explains the first MB memory map. Appendix E provides the specifications for the built-in power

supply.

Page 15 of the Apollo Commercial Clothes Dryer (150 III) user manual — SYSTEM
Page 15 · click to enlarge
Page 15

1.3. Specifications

APOLLO12.1”/15.0” or 15.1” TFT Intel ® Celeron/Pentium ®

III Plastic-housing Panel PC with Versatile Stand design

SYSTEM

u APOLLO 12012.1” color TFT, 800*600 Viewing angle 100

Luminance (cd/m2) 150 or above Simultaneous mode yes u APOLLO 150: 15.0”/15.1” color TFT, 1024*768 Viewing angle 120 Luminance (cd/m2) 250/200 or above, optional high-luminance model

u Intel Pentium III FCPGA 1GHz/133MHz u Intel Pentium III FCPGA 650-933/133MHz u Intel Pentium III FCPGA 500E-850E/100MHz u Intel Celeron FCPGA 800MHz-1.10GHz/100MHz u Intel Celeron FCPGA 533AMHz-766MHz/66MHz

u Intel Celeron PPGA 300A-533MHz/66MHz

u Award PnP Flash BIOS

u 1*168pin DIMM socket supporting SDRAM up to 512MB

Show 9 more labels / short text on this page
Flat Panel · Simultaneous mode yes · CPU (Socket 370) · System Chipset · u SiS 630ST · System BIOS · System Memory · L2 Cache · u CPU built-in
Page 16 of the Apollo Commercial Clothes Dryer (150 III) user manual — 1.3. Specifications
Page 16 · click to enlarge
Page 16
u Serial ports*4COM 1, 2 & 4 with +5V/12 power output

on pin #9, COM 3 internal type reserved for touchscreen, COM2 RS-232/485 jumper selectable

u Parallel Port*1supports SPP/EPP/ECP u External FDD Interface*1 u +5V/+12V DC-out*1 u PS/2 Keyboard Interface*1

u PS/2 Mouse Interface*1 u DIO: Input*2, output*2 u USB Interface*2 u VGA Interface*1 u Brightness VR*1 u Speaker-out, MIC-in, Line in

u 100/10 Base-T Ethernet with RJ-45 phone jack u Supports WAKE-ON-LAN

u Integrated 2D/3D graphics engine, 4X AGP

u Share system memory architecture able to utilize the

display memory size up to 64MB u Supporting LCD/VGA dual display mode (under

Windows 98 and Windows ME and Windows XP)

Show 4 more labels / short text on this page
Standard I/O · Ethernet · Watchdog Timer · Display
Page 17 of the Apollo Commercial Clothes Dryer (150 III) user manual — 1.3. Specifications
Page 17 · click to enlarge
Page 17

u Full duplex and independent sample rate converter for

audio recording & playback u Supports Microsoft DirectSound

u 3D positional audio effects u Hi-performance, mixed-signal, stereo u MIC-In, Speaker-Out, Line-In u Pin header for CD-audio in

u Monitoring processor & system u Monitoring 5VSB, VBAT, 1.5V, 3.3V, +5V, +12V, -12V, and

processor voltages u Monitoring processor, chassis fan speeds u Controlling processor and chassis fan speed and failure

u Automatic fan on/off control u Read back capability that displays temperature, voltage

u Supporting Intel processor thermal diode output (real

u PCI*2 or PCI*1 + ISA*1 u Expansion card size (L*W)

PCI card: max. 190*120 mm ISA card max. 190*120 mm if no internal FDD is installed; 170*120 mm if internal FDD is installed

u LED indicators for HDD, LAN, POWER

u IrDA receiver (optional)

Show 7 more labels / short text on this page
Audio Function · Hardware Monitor · alarm · and fan speed · processor temperature) · Expansion Slot · Front Bezel
Page 18 of the Apollo Commercial Clothes Dryer (150 III) user manual — PERIPHERAL & STORATE DEVICES
Page 18 · click to enlarge
Page 18

PERIPHERAL & STORATE DEVICES

Touchscreen (optional, sharing COM3)

u 12.1”/15.1” analog resistive type with RS-232 controller u 12.1”/15.1” capacitive type with RS-232 controller

u 12.1”/15.1” surface acoustic wave type (SAW)

u ATX 150W, input range100~240V/5A @60Hz,

200~240V/2.5A @50Hz u DC 150W, 20~28VDC, 40~56VDC or DC 200W, 36~72VDC

CD-ROM or CD-RW or DVD-ROM or COMBO

u Slim type*1 (optional) or u External type via USB

u Slim type*1 (optional) or u Via external FDD or u External type via USB

u 3.5" HDD*1 (optional) or 2.5” HDD x 2 (optional)

Show 6 more labels / short text on this page
Power Supply · (optional) · Speakers · u Water-proof speakers*2 · Floppy Disk Drive · Hard Disk Drive
Page 19 of the Apollo Commercial Clothes Dryer (150 III) user manual — MECHANICAL & ENVIRONMENTAL
Page 19 · click to enlarge
Page 19

MECHANICAL & ENVIRONMENTAL

u Insideheavy-duty steel u Outside: fire-proof resilient ABS/PC plastic

u Beige u Black

Dimension (chassis only, unitmm)
u APOLLO 120368*321*116.5 (L*W*D);

334.7*284.21 (for panel mount) u APOLLO 150: 406*360*129 (L*W*D);

384*284.2 (for panel mount)

u Panel mount with mounting kits u Wall mount with swing arm: standard VESA mounting

u 45~90o free standing u Avocado-shape holes for fixed standing

u Cable Management design

§ Specifications are subject to change without notice.

Show 5 more labels / short text on this page
Construction · Color (standard) · Mounting · holes (75*75 mm) · Versatile Stand
Page 20 of the Apollo Commercial Clothes Dryer (150 III) user manual — 1.4. Dimensions
Page 20 · click to enlarge
Page 20

1.4. Dimensions

1.4.1. APOLLO 120

The APOLLO 120’s chassis size is shown below. This does not include the dimension of the stand. This does not include the dimension of the stand.

Apollo Commercial Clothes Dryer (150 III) — 1.4. Dimensions diagram (page 20)
Fig. 2 · 1.4. Dimensions
Page 21 of the Apollo Commercial Clothes Dryer (150 III) user manual — 1.4.2. APOLLO 150
Page 21 · click to enlarge
Page 21

1.4.2. APOLLO 150

The APOLLO 150’s chassis size is shown below. This does not include the dimension of the stand.

Apollo Commercial Clothes Dryer (150 III) — 1.4.2. APOLLO 150 diagram (page 21)
Fig. 3
Page 22 of the Apollo Commercial Clothes Dryer (150 III) user manual — 1.4.2. APOLLO 150
Page 22 · click to enlarge
Page 22
Page 22 of the Apollo Commercial Clothes Dryer (150 III) user manual — 1.4.2. APOLLO 150
Page 23 of the Apollo Commercial Clothes Dryer (150 III) user manual — 2. U SING THE S YSTEM
Page 23 · click to enlarge
Page 23

2. U SING THE S YSTEM

u Identifying the APOLLO system u System setup for the first-time use

Page 24 of the Apollo Commercial Clothes Dryer (150 III) user manual — 2.1.1. Front View
Page 24 · click to enlarge
Page 24

2.1. Identifying the System

Before getting started, take a moment to familiarize yourself with the system and the I/O arrangement of the APOLLO 120/150.

2.1.1. Front View

When the APOLLO 120/150 is put upright on the desktop with the provided pedestal, its front view appears as below.

The illustrations of the APOLLO 120/150 may differ slightly because the APOLLO system series has two different LCD size: 12.1” & 15.1”.

Apollo Commercial Clothes Dryer (150 III) — 2.1.1. Front View diagram (page 24)
Fig. 4 · 2.1.1. Front View

12.1”/ 15.1” LCD & touchscreen

Side door for two

Wireless KB sensor or

Motion sensor or IrDA

Show 9 more labels / short text on this page
FDD drive & · CD-ROM drive · PCI/ISA expansion outlet · Fire-proof resilient plastic · Speaker · Cable management · covers · Versatile stand for · desktop standing
Page 25 of the Apollo Commercial Clothes Dryer (150 III) user manual — CD-ROM
Page 25 · click to enlarge
Page 25

2.1.2. Side Views

The left side of the panel PC appears as below:

Screw holes for peripheral

Apollo Commercial Clothes Dryer (150 III) — 2.1.2. Side Views diagram (page 25)
Fig. 5 · 2.1.2. Side Views

CD-ROM

Side door for two PCI/ISA

Base covers +pedestal = versatile stand

Show 5 more labels / short text on this page
device attachment · Floppy disk drive · expansion outlet · Cable management · cutout
Page 26 of the Apollo Commercial Clothes Dryer (150 III) user manual — P . USB*2
Page 26 · click to enlarge
Page 26

2.1.3. I/O Outlets

When you turn around the APOLLO system, you will find the power switch and all the I/O ports are located at the rear cover of the panel PC.

Apollo Commercial Clothes Dryer (150 III) — 2.1.3. I/O Outlets diagram (page 26)
Fig. 6 · 2.1.3. I/O Outlets

A B C D E F G H I

J K L M N O P

A. COM 4 B. EXTERNAL FDD C. COM 2

D. VGA PORT E. COM 1 F. PRINTER PORT

G. PS/2 MOUSE H. +5/12V DC-OUT I. PS/2 KEYBOARD

J. VR BRIGHTNESS K. SPEAKER-OUT L. LINE-IN

M. MIC-IN N. ETHERNET (RJ-45) O. 2-CHANNEL DIO

P . USB*2

Page 27 of the Apollo Commercial Clothes Dryer (150 III) user manual — 2.2.1. Installation Procedures
Page 27 · click to enlarge
Page 27

2.2. System Setup for the First-time Use

To set up the APOLLO 120/150 for the first-time use, you should have the following items ready. The items are either in the accessory box or available in any computer stores. u 110V or 220V power cord

u PS/2 or AT keyboard or wireless keyboard u PS/2 or serial mouse

2.2.1. Installation Procedures

The APOLLO system can be powered either by an AC electrical outlet (100~240V/5A @60Hz, 200~240V/2.5A @50Hz) or by DC power source (20~28VDC or 40~56VDC or 36~72VDC). If the system is to be powered up by AC power, be sure to use the right power cord (110V or 220V) for connection.

1. Connect the female end of the power cord to the AC inlet located at the rear bottom side of the panel PC. 2. Connect the 3-pin male end of the power cord to an electrical outlet.
3. Connect a PS/2 keyboard or an AT keyboard to keyboard port. If you are using an AT keyboard, you need an adapter (AT to PS/2 KB) for this connection. 4. Connect the PS/2 mouse to the PS/2 mouse port. If you are using a serial mouse, it can be connected to the COM port.
5. Turn on the main switch on the power supply if there is one. 6. Power on the panel PC by switching the power switch located at the rear bottom side.
Page 28 of the Apollo Commercial Clothes Dryer (150 III) user manual — 2.2.2. Running the BIOS Setup
Page 28 · click to enlarge
Page 28

2.2.2. Running the BIOS Setup

If you are a commercial user, the APOLLO 120/150 III should have been properly set up and configured by your dealer. You may still find it necessary to change the system configuration information. In this case, you need to run the system’s BIOS setup program. Under the following conditions, the CMOS settings are to be changed. 1. The system is starting for the first time. 2. The hardware devices attached to the APOLLO III system have been changed.

3. The CMOS memory has lost power and the configuration information has been erased.

The BIOS setup program is stored in ROM, which can be accessed by pressing key on the keyboard immediately when the system is powered on. In order to retain the specified setup information when the system power is turned off, the system setup information is stored in a battery-backed CMOS RAM. The battery is to ensure the settings will not be erased when the computer is turned off or reset. When the computer is powered on again, the system will read the settings stored in the CMOS RAM and compare them to the equipment check conducted during the power on self-test (POST). If any error or mismatch occurs, an error message will be shown on the screen and the computer will be prompted to run the setup program.

To change the BIOS setup, please refer to Chapter 7 for more information.

Page 29 of the Apollo Commercial Clothes Dryer (150 III) user manual — 2.2.3. Operating System and Driver Installation
Page 29 · click to enlarge
Page 29

2.2.3. Operating System and Driver Installation

The APOLLO III system is not equipped with an operating system when delivered from the original manufacturer. If you are a commercial user, the system is likely to have been pre-installed proper operating system and software drivers by your dealer or system integrator. If the system is not pre-installed with any system OS and drivers or you intend to install your preferred ones, there are several ways to load OS and software into the system.

1. Via the external FDD or internal FDD 2. Via the CD-ROM
3. Via Ethernet: You can boot up the system via Ethernet bootrom (optional) and download system OS or software from the network.

Recent releases of operating systems always include setup programs that load automatically and guide you through the installation. You can also refer to your OS user manual for instructions on formatting or partitioning the hard disk drive before any software installation.

The APOLLO III system provides the following utility drivers stored in the CD-ROM diskette or utilities diskettes; ² Ethernet utilities ² VGA utilities

² Audio drivers ² Touchscreen drivers

Page 30 of the Apollo Commercial Clothes Dryer (150 III) user manual — 2.2.3. Operating System and Driver Installation
Page 30 · click to enlarge
Page 30
Page 30 of the Apollo Commercial Clothes Dryer (150 III) user manual — 2.2.3. Operating System and Driver Installation
Page 31 of the Apollo Commercial Clothes Dryer (150 III) user manual — 3. V ERSATILE STANDING & MOUNTING OPTIONS
Page 31 · click to enlarge
Page 31

3. V ERSATILE STANDING & MOUNTING OPTIONS

The APOLLO 120/150 is designed for universal standing and mounting to fit into various environmental applications. This chapter highlights the steps of different mounting options with graphical illustrations. Sections include u Versatile Stand u Wall Mounting u Panel Mounting

Page 32 of the Apollo Commercial Clothes Dryer (150 III) user manual — 3.1.2. 45 to 90 0 Free Standing
Page 32 · click to enlarge
Page 32

3.1. Versatile Stand

The APOLLO comes with a versatile and functional stand, able to fit into different environmental application.

3.1.1. Standing Upright

Compact in its size, all-in-one in its design along with its industrial-grade reliability, the APOLLO system standing upright is the best replacement for a desktop computer. When the APOLLO is to stand upright, the two base back covers can either be assembled or not to be assembled to the pedestal. However, if the APOLLO system is to stand upright while the touchscreen is also frequently used, then it is suggested that the two base back covers and another knob are assembled with the pedestal to prevent possible wobbling when the touchscreen is being used.

3.1.2. 45 to 90 0 Free Standing

The sleek and sturdy pedestal assembled with the two cable management covers enables the APOLLO system to endure the long-time operation in any public sectors. By swiveling the knob on the left side of the base cover and pulling the base up and down, the angle can be adjusted from 45 to 900.

Apollo Commercial Clothes Dryer (150 III) — 3.1.2. 45 to 90 0 Free Standing diagram (page 32)
Fig. 7 · 3.1.2. 45 to 90 0 Free Standing

Cable management cover

Page 33 of the Apollo Commercial Clothes Dryer (150 III) user manual — 3.1.3. Fixed Standing
Page 33 · click to enlarge
Page 33

3.1.3. Fixed Standing

At the bottom side of the big pedestal, there are two avocado-shape holes which are used to fix the APOLLO to the table with screws. When the APOLLO is fixed to the table, the angle from the main system to the table can be adjusted from 45 to 900 by swiveling the knob on the left side of the base cover and pulling the base up and down.

Apollo Commercial Clothes Dryer (150 III) — 3.1.3. Fixed Standing diagram (page 33)
Fig. 8 · 3.1.3. Fixed Standing

HINGE (¥“ ) with LOCK HINGE (¥k) APOLLO 120/150 ´à ¶b›× „¢ ⁄U»\

´à ¶b⁄ä ‹[ APOLLO 120/150 ´à ¶b›× „¢ ⁄W »\

The following figure illustrates the distance between the avocado holes.

Apollo Commercial Clothes Dryer (150 III) — 3.1.3. Fixed Standing diagram (page 33)
Fig. 9 · 3.1.3. Fixed Standing
F IGURE 3-3APOLLO PEDESTAL B ASE AVOCADO HOLES
Page 34 of the Apollo Commercial Clothes Dryer (150 III) user manual — 3.1.4. Cable Management
Page 34 · click to enlarge
Page 34

3.1.4. Cable Management

The APOLLO’s pedestal is not only a versatile stand but a functional stand able to manage the system cabling.

1. The rectangle-shape opening (Fig. 3-2) at the bottom side of the big pedestal can act as a cable management cutout. All the cables connecting to the I/O ports can come out from this opening, then down to the table.
2. The two base back covers (Fig. 3-1) can act as a set of cable management covers. All the cables connecting to the I/O ports come down in the covers, then out from this opening at the rear side of the base.
Page 35 of the Apollo Commercial Clothes Dryer (150 III) user manual — 3.2. Wall Mounting and Mobile Applications
Page 35 · click to enlarge
Page 35

3.2. Wall Mounting and Mobile Applications

The APOLLO system provides 1 set of VESA mounting holes, 75*75mm on the rear side of the chassis. System integrators can design their special wall mount brackets per the two sets of VESA holes or obtain market-available swing arms for wall mounting, table mounting or mobile applications.

Apollo Commercial Clothes Dryer (150 III) — 3.2. Wall Mounting and Mobile Applications diagram (page 35)
Fig. 10 · 3.2. Wall Mounting and Mobile Applications
Page 36 of the Apollo Commercial Clothes Dryer (150 III) user manual — F IGURE 3-6 F IGURE 3-7
Page 36 · click to enlarge
Page 36
Apollo Commercial Clothes Dryer (150 III) — F IGURE 3-6 F IGURE 3-7 diagram (page 36)
Fig. 11
Apollo Commercial Clothes Dryer (150 III) — F IGURE 3-6 F IGURE 3-7 diagram (page 36)
Fig. 12
Apollo Commercial Clothes Dryer (150 III) — F IGURE 3-6 F IGURE 3-7 diagram (page 36)
Fig. 13

F IGURE 3-6 F IGURE 3-7

Page 37 of the Apollo Commercial Clothes Dryer (150 III) user manual — 3.3. Panel Mounting
Page 37 · click to enlarge
Page 37

3.3. Panel Mounting

The APOLLO system provides a set of optional mounting brackets for system panel mounting. The following figures illustrate the way to use the brackets for panel mounting.

Apollo Commercial Clothes Dryer (150 III) — 3.3. Panel Mounting diagram (page 37)
Fig. 14 · 3.3. Panel Mounting
Page 38 of the Apollo Commercial Clothes Dryer (150 III) user manual — HERCULES PK
Page 38 · click to enlarge
Page 38

3.4. KIOSK Integration

The APOLLO system can also be integrated to a KIOSK cabinet to make a ready-to-play KIOSK terminal. The following is an example of APOLLO KIOSK. It is a flexible and robust device that can be mounted virtually anywhere and in any forms including tabletop, pedestal, pole and wall mounting.

Apollo Commercial Clothes Dryer (150 III) — 3.4. KIOSK Integration diagram (page 38)
Fig. 15 · 3.4. KIOSK Integration
Apollo Commercial Clothes Dryer (150 III) — 3.4. KIOSK Integration diagram (page 38)
Fig. 16 · 3.4. KIOSK Integration
Apollo Commercial Clothes Dryer (150 III) — 3.4. KIOSK Integration diagram (page 38)
Fig. 17 · 3.4. KIOSK Integration

HERCULES T

HERCULES M

Apollo Commercial Clothes Dryer (150 III) — HERCULES T diagram (page 38)
Fig. 18

HERCULES PK

HERCULES P

HERCULES K

Page 39 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4. I/O C ONNECTION
Page 39 · click to enlarge
Page 39

4. I/O C ONNECTION

This chapter describes the APOLLO system I/O ports and how to use the I/O interface to connect to external devices.

Page 40 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4. I/O C ONNECTION
Page 40 · click to enlarge
Page 40

The I/O interfaces located at the rear side of the chassis are used to connect external peripheral devices, such as a mouse, a keyboard, a monitor, serial devices or parallel printer…etc. Before any connection, make sure that the computer and the peripheral devices are turned off.

Apollo Commercial Clothes Dryer (150 III) — 4. I/O C ONNECTION diagram (page 40)
Fig. 19

The APOLLO 120/150 can support the latest EPP and ECP parallel port protocols. It can be used to connect to a wide array of printers, ZIP drive, parallel scanner and any other parallel devices. The printer interface on the APOLLO 120/150 III is a 25-pin female D-SUB connector. To connect any parallel device, follow the steps below:

1. Turn off the system and the parallel devices.
2. Plug in the male connector of the parallel device to the 25-pin female D-SUB connector and fasten the retaining screws. 3. Turn on the system and the attached parallel devices. 4. Refer to the parallel device’s manual for instruction to configure the operation environment to recognize the new attached devices.
5. You may need to run the CMOS setup to change the hardware device setup.
Page 41 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4.2. COM Ports x 4
Page 41 · click to enlarge
Page 41

4.2. COM Ports x 4

The APOLLO 120/150 features with four onboard COM ports. COM 1, 2 & 4 are D-SUB serial ports located at the rear side of the chassis, ready to connect to a wide range of serial devices. COM 3 is internal serial port reserved for touchscreen for internal connection. COM1, COM3 and COM4 are RS-232 and COM2 is RS-232/422/485, selected via jumper setting. For COM 2 RS-232/422/485 selection, please refer to SEC. 6.1.2.

COM 1, 2 & 4 are equipped with +5V/+12V power capabilities on pin 9, providing easy accommodation to a broad range of serial devices.

The COM port 5V/12 power is selected via jumper setting on the IO board. The IO is the signal board attached to the rear panel with 2 SCSI cables linking to the system motherboard to connect the onboard signal out to the external I/O ports.

Please refer to SEC. 6.2.2 for 5V/12 power selection.

Page 42 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4.2. COM Ports x 4
Page 42 · click to enlarge
Page 42

If a touchscreen module is installed, for factory default setting, its controller will occupy COM3. COM1, 2 & COM4 are all D-SUB 9-pin connectors. To connect to any serial device; follow the procedures below;

1. Turn off the APOLLO system and the serial devices. 2. Attach the interface cable of the serial device to the 9-pin D-SUB serial connector. Be sure to fasten the retaining screws. 3. Turn on the computer and the attached serial devices.
4. Refer to the serial device’s manual for instruction to configure the operation environment to recognize the new attached devices.
5. If the serial device needs specified IRQ or address, you may need to run the CMOS setup to change the hardware device setup. If the COM2 is to be set to RS-422/485 for long distance transmission, the related onboard jumpers have to be set correctly first. Refer to section 6.1.4.3 for the RS-232/422/485 jumper settings.
Page 43 of the Apollo Commercial Clothes Dryer (150 III) user manual — RJ-45
Page 43 · click to enlarge
Page 43

4.3. 100/10 Base-T Ethernet (RJ-45)

The APOLLO 120/150 provides a 100/10 Base-T NE2000 compatible Ethernet (RJ-45) interface. For network connection, follow the instructions below. 1. Turn of the APOLLO system and the Ethernet hubs.

2. Plug in one end of cable of a 100/10 Base-T hub to the system’s RJ-45 phone jack. The pin assignment of the RJ-45 is listed as follow;

1 2 3 4 5 6 7 8

RJ-45 Connector Pin Assignment

RJ-45

Tx+ (data transmission positive) Tx- (data transmission negative) Rx+ (data reception positive) Rx- (data reception negative) No use 4.4. VGA Interface

1 2 3 6 others

The APOLLO 120/150 has a 15-pin analog RGB connector located at the rear side of the chassis. It can support its own LCD display and an expansion CRT or analog monitor at the same time. The connection to an analog monitor is an easy plug-in of the VGA D-SUB 15-pin connector to the RGB interface.

Pin Description

Page 44 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4.5.1. When System Memory Clock = 66MHz
Page 44 · click to enlarge
Page 44

4.5. 2 nd Display Graphic Support Mode

The APOLLO can support SINGLE DISPLAY MODE and DUAL DISPLAY

MODE. For dual display mode, it can support MIRROR MODE (same screen) or MULTIPLE-MONITOR MODE (different screens). PLEASE NOTE THAT THE MULTIPLE-MONITOR MODE ONLY WORKS WHEN

THE OPERATING SYSTEM IS WINDOWS 98 OR WINDOWS ME OR WINDOWS XP.

The APOLLO itself is onboard with an AGP LCD/VGA controller. When dual display mode is activated, it can support a LCD panel (digital TTL) and a CRT or an analog monitor at either mirror mode or multiple-monitor mode.

The following sections describe all the graphic support modes based on system memory clock frequency (66MHz, 100MHx and 133MHz). All these tables apply only to video memory size is equal or larger than 8MB.

4.5.1. When System Memory Clock = 66MHz

The following tables contain all graphic support modes under the following condition and are classified under three output modes (single mode, mirror mode and multiple-monitor mode).

System memory clock = 66MHz Memory bus width = 64 bit

Video memory size = 8MB or above

Page 45 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4.5. 2 nd Display Graphic Support Mode
Page 45 · click to enlarge
Page 45

4.5.1.1. Single Display Mode

Resolution Bpp CRT1 LCD

640*480 8 60, 72, 75, 85, 100, 120, 160, 200 60, 70, 75

16 60, 72, 75, 85, 100, 120, 160, 200 60, 70, 75

32 60, 72, 75, 85, 100, 120, 160 60, 70, 75

800*600 8 56, 60, 72, 75, 85, 100, 120, 160 60, 70, 75

16 56, 60, 72, 75, 85, 100, 120, 160 60, 70, 75

32 56, 60, 72, 75, 85, 100, 120 60, 70, 75

1024*768 8 43, 60, 70, 75, 85, 100, 120 60, 70, 75

16 43, 60, 70, 75, 85, 100, 120 60, 70, 75

32 43, 60, 70, 75

1280*1024 8 43, 60, 75, 85 60

16 43, 60, 75, 85

1600*1200 8 60, 65, 70, 75, 85

1920*1440 8 60

Page 46 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4.5. 2 nd Display Graphic Support Mode
Page 46 · click to enlarge
Page 46

4.5.1.2. Mirror Display Output Mode

When LCD is selected as secondary display at mirror mode:

Resolution Bpp CRT1 at mirror mode LCD at mirror mode

640*480 8 60, 72, 75, 85, 100,

16 60, 72, 75, 85, 100,

32 60, 72, 75, 85, 100 60

800*600 8 56, 60, 72, 75, 85, 100,

16 56, 60, 72, 75, 85, 100,

1024*768 8 43, 60, 70, 75, 85, 100,

Show 8 more labels / short text on this page
60, 70, 75 · 120, 160, 200 · 60, 70, 75 · 120, 160, 200 · 60, 70, 75 · 120, 160 · 60, 70, 75 · 60, 70, 75
Page 47 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4.5. 2 nd Display Graphic Support Mode
Page 47 · click to enlarge
Page 47

4.5.1.3. Multiple Display Output Mode

When LCD is selected as secondary display at multiple-monitor mode:

Resolution Bpp CRT1 at MM mode LCD at MM mode

640*480 8 60, 72, 75, 85, 100,

16 60, 72, 75, 85, 100,

32 60, 72, 75, 85, 100 60

800*600 8 56, 60, 72, 75, 85, 100,

16 56, 60, 72, 75, 85, 100,

1024*768 8 43, 60, 70, 75, 85, 100,

16 43, 60, 70, 75

1280*1024 8 43, 60, 75, 85

1600*1200 8 60, 65

Show 9 more labels / short text on this page
60, 70, 75 · 120, 160, 200 · 60, 70, 75 · 120, 160, 200 · 60, 70, 75 · 120, 160 · 60, 70, 75 · 32 56, 60 · 60, 70, 75
Page 48 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4.5.2. When System Memory Clock = 100MHz
Page 48 · click to enlarge
Page 48

4.5.2. When System Memory Clock = 100MHz

The following tables contain all graphic support modes under the following condition and are classified under three output modes (single mode, mirror mode and multiple-monitor mode).

System memory clock = 100MHz Memory bus width = 64 bit

Video memory size = 8MB or above

4.5.2.1. Single Display Mode

Resolution Bpp CRT1 LCD

640*480 8 60, 72, 75, 85, 100, 120, 160, 200 60, 70, 75

16 60, 72, 75, 85, 100, 120, 160, 200 60, 70, 75

32 60, 72, 75, 85, 100, 120, 160, 200 60, 70, 75

800*600 8 56, 60, 72, 75, 85, 100, 120, 160 60, 70, 75

16 56, 60, 72, 75, 85, 100, 120, 160 60, 70, 75

32 56, 60, 72, 75, 85, 100, 120, 160 60, 70, 75

1024*768 8 43, 60, 70, 75, 85, 100, 120 60, 70, 75

16 43, 60, 70, 75, 85, 100, 120 60, 70, 75

32 43, 60, 70, 75, 85, 100 60, 70, 75

1280*1024 8 43, 60, 75, 85 60

16 43, 60, 75, 85 60

1600*1200 8 60, 65, 70, 75, 85

16 60, 65, 70, 75, 85

32 43, 60 · 1920*1440 8 60

Page 49 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4.5.2. When System Memory Clock = 100MHz
Page 49 · click to enlarge
Page 49

4.5.2.2. Mirror Display Output Mode

When LCD is selected as secondary display at mirror mode:

Resolution Bpp CRT1 at mirror mode LCD at mirror mode

640*480 8 60, 72, 75, 85, 100,

16 60, 72, 75, 85, 100,

32 60, 72, 75, 85, 100,

800*600 8 56, 60, 72, 75, 85, 100,

16 56, 60, 72, 75, 85, 100,

32 56, 60, 72, 75, 85 60

1024*768 8 43, 60, 70, 75, 85, 100,

16 43, 60, 70, 75, 85, 100,

Show 12 more labels / short text on this page
60, 70, 75 · 120, 160, 200 · 60, 70, 75 · 120, 160, 200 · 60, 70, 75 · 120, 160 · 60, 70, 75 · 120, 160 · 60, 70, 75 · 120, 160 · 60, 70, 75 · 60, 70, 75
Page 50 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4.5.2. When System Memory Clock = 100MHz
Page 50 · click to enlarge
Page 50

4.5.2.3. Multiple Display Output Mode

When LCD is selected as secondary display at multiple-monitor mode:

Apollo Commercial Clothes Dryer (150 III) — 4.5.2. When System Memory Clock = 100MHz diagram (page 50)
Fig. 20 · 4.5.2. When System Memory Clock = 100MHz

Resolution Bpp CRT1 at MM mode LCD at MM mode

Page 51 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4.5.3. When System Memory Clock = 133MHz
Page 51 · click to enlarge
Page 51

4.5.3. When System Memory Clock = 133MHz

The following tables contain all graphic support modes under the following condition and are classified under three output modes (single mode, mirror mode and multiple-monitor mode).

System memory clock = 133MHz Memory bus width = 64 bit

Video memory size = 8MB or above

Page 52 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4.5.3. When System Memory Clock = 133MHz
Page 52 · click to enlarge
Page 52

4.5.3.1. Single Display Mode

Resolution Bpp CRT1 LCD

640*480 8 60, 72, 75, 85,

16 60, 72, 75, 85,

32 60, 72, 75, 85,

800*600 8 56, 60, 72, 75,

16 56, 60, 72, 75,

32 56, 60, 72, 75,

1024*768 8 43, 60, 70, 75,

16 43, 60, 70, 75,

32 43, 60, 70, 75,

1280*1024 8 43, 60, 75, 85 60

16 43, 60, 75, 85 60

32 43, 60, 75, 85 60

1600*1200 8 60, 65, 70, 75,

16 60, 65, 70, 75,

Show 19 more labels / short text on this page
60, 70, 75 · 100, 120, 160, · 60, 70, 75 · 100, 120, 160, · 60, 70, 75 · 100, 120, 160, · 60, 70, 75 · 85, 100, 120, · 60, 70, 75 · 85, 100, 120, · 60, 70, 75 · 85, 100, 120, · 60, 70, 75 · 85, 100, 120 · 60, 70, 75 · 85, 100, 120 · 60, 70, 75 · 85, 100, 120 · 1920*1440 8 60
Page 53 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4.5.3. When System Memory Clock = 133MHz
Page 53 · click to enlarge
Page 53

4.5.3.2. Mirror Display Output Mode

When LCD is selected as secondary display at mirror mode:

Resolution Bpp CRT1 at mirror mode LCD at mirror mode

640*480 8 60, 72, 75, 85, 100,

16 60, 72, 75, 85, 100,

32 60, 72, 75, 85, 100,

800*600 8 56, 60, 72, 75, 85, 100,

16 56, 60, 72, 75, 85, 100,

32 56, 60, 72, 75, 85, 100,

1024*768 8 43, 60, 70, 75, 85, 100,

16 43, 60, 70, 75, 85, 100,

Show 13 more labels / short text on this page
60, 70, 75 · 120, 160, 200 · 60, 70, 75 · 120, 160, 200 · 60, 70, 75 · 120, 160, 200 · 60, 70, 75 · 120, 160 · 60, 70, 75 · 120, 160 · 60, 70, 75 · 60, 70, 75 · 60, 70, 75
Page 54 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4.5.3. When System Memory Clock = 133MHz
Page 54 · click to enlarge
Page 54

4.5.3.3. Multiple Display Output Mode

When LCD is selected as secondary display at multiple-monitor mode:

Apollo Commercial Clothes Dryer (150 III) — 4.5.3. When System Memory Clock = 133MHz diagram (page 54)
Fig. 21 · 4.5.3. When System Memory Clock = 133MHz

Resolution Bpp CRT1 at MM mode LCD at MM mode

Page 55 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4.7. PS/2 Mouse Interface
Page 55 · click to enlarge
Page 55

4.6. PS/2 Keyboard Interface

The APOLLO provides a standard PS/2 keyboard connector located at the rear panel. If the user would like to use AT keyboard, then an adapter to connect the PS/2 KB to AT KB is needed.

4.7. PS/2 Mouse Interface

The APOLLO system has one PS/2 mouse connector located at the rear side. A simple plug-in will make the connection.

Page 56 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4.8. External FDD (DB-15)
Page 56 · click to enlarge
Page 56

4.8. External FDD (DB-15)

The APOLLO 120/150 provides two ways to connect to a floppy disk drive to fit into specific environmental applications: 1. Internal FDD

2. External FDD If the FDD is frequently used, it is suggested to use an internal floppy disk drive. If the drive is used only for system installation or maintenance, then, an external device can fulfill this need and is more economical. Please note that if an internal floppy disk drive already exists, no external floppy drive can be used.

The APOLLO external FDD interface is a 15-pin D-sub connector located at the rear side of the chassis. An external FDD cable is provided to connect a standard 3.5” FDD to the system. Its pin position and pin assignment are listed as follows.

Apollo Commercial Clothes Dryer (150 III) — 4.8. External FDD (DB-15) diagram (page 56)
Fig. 22 · 4.8. External FDD (DB-15)

The APOLLO system is equipped with a +5V/12V DC-out connector to provide 5V power to drive the external floppy disk drive. Use the provided FDD power cable to connect the floppy drive to the 5V DC-out connector when an external floppy drive is attached to the system.

Page 57 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4.9. +5V/12V DC-Out
Page 57 · click to enlarge
Page 57

4.9. +5V/12V DC-Out

The APOLLO system provides a +5V/12V DC-out connector. It is used to provide necessary power source for some external devices. For example, if the APOLLO III system is to be housed in a KIOSK cabinet which requests extra cooling fan for heat dispensing, then the fan power cable can be attached to 5V/12V DC-out to obtain power from the computer directly. If an external floppy disk drive is attached to the system, it will need +5V power source from the system. A power cable for the external floppy disk drive is already provided for this connection. For other devices, you might need to make your own power cable for the connection. 4.10. VR Brightness Control

The APOLLO system provides a VR control to adjust the brightness of the LCD. The VR control is with a “+” shape cutout on it. You will need a “+” shape screwdriver to adjust it for display brightness control.

Page 58 of the Apollo Commercial Clothes Dryer (150 III) user manual — DIO1
Page 58 · click to enlarge
Page 58

4.11. DIO (Digital Input & Output)

The APOLLO III provides 2-channel digital input and output that can be used for the system’s simple automation control needs. The digital I/O can be configured to control the opening of a cash drawer or to sense the warning signal of an uninterrupted power system (UPS) or to do the store security control. The DIO port address and pin definition is listed below;

DIO1 RJ11

I/O Port address208H
ReadSD0, SD1 Write: SD4, SD5

1 2 3 4 5 6

Apollo Commercial Clothes Dryer (150 III) — DIO1 RJ11 diagram (page 58)
Fig. 23
Apollo Commercial Clothes Dryer (150 III) — DIO1 RJ11 diagram (page 58)
Fig. 24

2 18 4 16 6 14 8 12 11 9 13 7 15 5 17 3

1A1 1Y1 1A2 1Y2 1A3 1Y3 1A4 1Y4 2A1 2Y1 2A2 2Y2 2A3 2Y3 2A4 2Y4

74LS244

74LS273

Apollo Commercial Clothes Dryer (150 III) — 74LS244 diagram (page 58)
Fig. 25

DIO1

RJ11

Page 59 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4.11. DIO (Digital Input & Output)
Page 59 · click to enlarge
Page 59

The Digital I/O is of TTL interface. It is controlled via software programming.

Input/output address208H

Out_Data 0~3 SD4~SD7 EXAMPLE: 10 REM Digital I/O example program 20 X = INP (&H208) REM INPUT Digital I/O port

for 4 bit 30 X = OUT (&H208) REM OUTPUT Digital I/O port for 4 bit 60 END 100 Return

Digital I/O Programming · In_Data 0~3=SD0~SD1 · Port 208H Definition

Page 60 of the Apollo Commercial Clothes Dryer (150 III) user manual — 4.14. IR Keyboard Sensor (optional)
Page 60 · click to enlarge
Page 60

4.12. Audio Interface (Line-in, MIC-in, SPK-out)

The audio interface contains three jacks, microphone-in, line-in and speaker-out.

The microphone-in jack is used to record sound or voice by connecting to an external microphone. The line-in jack is used to input audio from an external audio device such as a CD player, tape recorder or a radio. The speaker-out jack is to output the audio to external devices such as speakers or earphones. The audio device can be directly attached to the jacks. Please note that the audio driver has to be installed first before using any audio device. 4.13. USB Ports

The APOLLO 120/150 III also provides two USB ports to connect to external USB devices. A simple plug-in of the USB device interface cable to the USB port will make the connection. Before using the USB devices, remember to install the device driver first.

4.14. IR Keyboard Sensor (optional)

The APOLLO III features with an optional IR keyboard sensor. The IR KB sensor containing wireless KB firmware is located at the front bezel. To use the wireless keyboard, please note that the APOLLO III IrKB sensor on the front bezel and the wireless keyboard sensor have to face each other at the same horizontal level and the distance of the IR transceiver and receiver should not exceed 1 meter. 4.15. AC/DC Inlet/Power Switch

For APOLLO 120/150 III AC system, it can operate in the input range from 100 ~ 240 volts, 50 ~ 60 Hz. For DC system, the input range can be from 18V to 72V with different power supply.

Page 61 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5. HARDWARE INSTALLATION AND UPGRADE
Page 61 · click to enlarge
Page 61

5. HARDWARE INSTALLATION AND UPGRADE

This chapter overviews the installation of the APOLLO III’s internal components and devices. This chapter is for service engineers not for the end user. Sections include:

u The exploded diagram u Motherboard assembly u Touchscreen controller u LCD module assembly u Front Bezel assembly

u HDD module assembly u CD-ROM/FDD assembly u Power module assembly u Expansion slots u Stand assembly

Page 62 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5. HARDWARE INSTALLATION AND UPGRADE
Page 62 · click to enlarge
Page 62

The APOLLO 120/150 III consists of a Celeron/ Pentium ® III multimedia motherboard with an adequate CPU and relevant SDRAM on it. The system control board and other internal devices such as expansion card, HDD and power supply are already housed in a plastic rear cover. The system’s performance depends on the installed CPU and the capacity of the system memory and hard disk drive. In some circumstances, you might intend to upgrade or maintain the system. By removing the rear cover and the metal covers, the internal components such as CPU, SDRAM, HDD, internal FDD, CD-ROM and power supply can be easily accessed for maintenance and upgrade. The APOLLO is composed of 10 major modules. The installation procedure is also listed as below. 1. Motherboard module 2. Touchscreen controller module 3. HDD module

4. LCD module 5. Front bezel module 6. CD-ROM/FDD module 7. Power supply module 8. Expansion slot module 9. Back panel module 10. Stand module

To disassemble the system module for maintenance, the procedure is from step 10 to 1.

Page 63 of the Apollo Commercial Clothes Dryer (150 III) user manual — F IGURE 5-1: APOLLO 120 EXPLODED DIAGRAM
Page 63 · click to enlarge
Page 63

5.1. Recognizing the System Major Parts

In terms of LCD size, the APOLLO has two models, one 12.1” and the other 15.1”. The assembly of the two models is basically the same except the LCD assembly. The following diagram highlights the system major parts that make up the APOLLO 120 main system.

Apollo Commercial Clothes Dryer (150 III) — 5.1. Recognizing the System Major Parts diagram (page 63)
Fig. 26 · 5.1. Recognizing the System Major Parts

CDROM-FDD†Õ «~ APOLLO 120 LCD†Õ «~ APOLLO 120 ›– “O†Õ «~

RISER CARD‚É –j–ì MODULE APOLLO RISER A1.0 POWER CABLE ⁄j4P-⁄p4P*2-2P 180mm

F IGURE 5-1: APOLLO 120 EXPLODED DIAGRAM

Page 64 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.1. Recognizing the System Major Parts
Page 64 · click to enlarge
Page 64

The following diagram shows the system major parts that make up the APOLLO 150 main system.

Apollo Commercial Clothes Dryer (150 III) — 5.1. Recognizing the System Major Parts diagram (page 64)
Fig. 27 · 5.1. Recognizing the System Major Parts

APOLLO 150 LCD†Õ «~ CDROM-FDD†Õ «~ ‰c¯Ø ¥D¾÷ “Oµ· ‰t⁄ø 302*148*0.35 PC620 …Ò †Õ A1.0 POWER CABLE ⁄j4P-⁄p4P*2-2P 180mm MODULE APOLLO RISER A1.0 RISER CARD‚É –j–ì POWER †Õ «~

¯K¥ó «Æ »\†Õ «~ HDD †Õ «~ TOUCH COM3 CABLE 80mm MODULE M2210 A1.0 µL⁄Õ ¯K⁄ø «Æ µ¡

Page 65 of the Apollo Commercial Clothes Dryer (150 III) user manual — F IGURE 5-3
Page 65 · click to enlarge
Page 65

5.2. Installing the CPU

The APOLLO III can adapt Socket 370 Intel Celeron or Pentium III CPU. Upgrading the CPU can increase the system performance. When Pentium III 1GB 133MHz is used with the system, it is suggested to attach another system cooling fan at the right side of the system compartment to prevent the system from overheating.

The APOLLO’s motherboard provides one 370-pin ZIF socket (Socket 370). The CPU must come with a CPU fan with a heat sink on to avoid overheating.

To install a CPU or upgrade a new CPU, follow the instructions below.

1. If there is an existing CPU on the socket, remove the CPU cooling fan first. Then remove the CPU by pulling the lever out a little and raising it, then lifting out the existing CPU from the socket.
2. To insert the CPU into the socket, the notch on the corner of the CPU (the corner with golden dot) should point toward the end of the socket lever. If the insertion of the CPU to the socket is not easy, check whether the CPU pins correspond with the holes on the socket.
3. After insert the CPU into the socket, pull the lever down to make sure the CPU is in place. 4. The CPU cooling fan comes with a 3-pin power cable. Connect the power cable to the 3-pin power connector, FAN1 on the motherboard.
5. There are two white clips on the CPU socket. Make sure the cooling CPU fan clips click into place.

3-pin CPU fan power connector

F IGURE 5-3

CPU socket

Page 66 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.3. Installing the SDRAM Memory Module
Page 66 · click to enlarge
Page 66

5.3. Installing the SDRAM Memory Module

The APOLLO 120/150 III system control board provides 1 x 168-pin DIMM socket, able to support SDRAM memory from 32MB up to 512MB. To install the memory module, follow the instructions below.

1. Find the 168 pin DIMM socket on the motherboard 2. There are two white eject levers at each end of the DIMM socket. Push them outward until they separate from the two vertical posts.
3. Holding the memory module with the notch on the upper right corner, then insert the memory module into the DIMM socket at 90 ° angle.
4. Push the two eject levers toward the vertical posts until they click into place. The memory module is now upright.

The system is able to auto detect the new memory size and there is no need to change the system configuration after installation. Make sure that the memory module you are using can handle the specified SDRAM MHz. Inadequate memory module will make the computer unable to boot up.

Page 67 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.4. Motherboard Assembly
Page 67 · click to enlarge
Page 67

5.4. Motherboard Assembly

The motherboard is the first component to be assembled to the system compartment. Follow the steps below to assemble the motherboard to the system chassis. Make sure the CPU with cooling fan and SDRAM are already properly installed to the motherboard before the motherboard is attached to the system chassis. (Refer to Sec. 5-2 and 5-3 for CPU and SDRAM installation).

1. The lower side of the chassis has a rectangle opening at the bottom of the chassis. Make the lower side of the chassis to be near you. 2. From your point of view, the motherboard module is to be installed to the lower side of the system compartment.
3. Tape the motherboard insulator (5) (Fig. 5-1 & 5-2 (5)) to the motherboard (6) first. The insulator is to separate the electronic components on the reverse side of the motherboard from the metal compartment to prevent short circuitry caused during system operation.
4. Fix the motherboard (6) to the chassis with 7 PMS anti-fallen 3*6 screws. 5. The IR/LED 2*13-pin cable (Fig. 5-7 (7) & Fig. 5-8 (5)) has to go through the rectangle opening located at the bottom side of the chassis, then connected to motherboard’s J9 , the HDD LED & ACPI LED & SMI connector.
Page 68 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.5. Touch Controller Assembly
Page 68 · click to enlarge
Page 68

5.5. Touch Controller Assembly

If a touchscreen is integrated with the system, the touchscreen controller is to be installed right after the installation of the motherboard. For easy maintenance in the future, the controller is to be installed to a bracket rather than to the system compartment directly. From your point of view, there is a rectangle opening at the left upper side of the chassis. Insert the touch controller bracket to the opening and retain it to the chassis with 2 FMS 3*5 screws.

For easy assembly, the related cables are to be connected first. 1. For Elo touch, the touchscreen cable (Fig. 5-1. (14)) is a 2*5-pin to 2*5-pin flat cable. One end is connected to the touchscreen controller first.

2. There is a 2-pin (black & red) cable to provide the power source for the touchscreen. Connect one end to the controller. 3. Connect the other end of the 2*5-pin to 2*5-pin flat cable to the onboard COM 3 box header connector and connect the other end of the 2-pin power cable to the motherboard’s PWR1 . 4. Fix the touchscreen controller (13) to the bracket with 2 PMS 3*6 screws.
5. Fold both cables properly. 6. Make sure the two screws at the outward upper side of the chassis are also properly fixed.
Page 69 of the Apollo Commercial Clothes Dryer (150 III) user manual — F IGURE 5-4: HDD INSTALLATION
Page 69 · click to enlarge
Page 69

5.6. HDD Module Assembly

The APOLLO provides enough space to build in a 3.5” hard disk drive in the system compartment. The following steps show the way to install an internal hard disk drive. 1. Make the chassis lower side near you. Now, from your point of view, the 3.5" HDD module is to be installed to the right upper side of the system compartment.

2. Refer to Figure 5-4. Fix the hard disk drive (1) to the HDD bracket (3) with one FTS 3*5 screw.
3. Connect the one end of the 40-pin IDE cable (2) to hard disk drive. 4. There are two clips at the bottom of the compartment used to hold the HDD module to the system compartment. Insert the HDD module to the compartment and clip it into place. Fix the HDD module to the chassis with one 3*5 FMS screw outside of the right upper side of the chassis.
5. Make sure the other end of the 40-pin IDE cable is connected to the motherboard IDE 1 connector.
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 69)
Fig. 28 · 5.6. HDD Module Assembly

F IGURE 5-4: HDD INSTALLATION

Page 70 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.7. Touchscreen or Front Bezel Assembly
Page 70 · click to enlarge
Page 70

5.7. Touchscreen or Front Bezel Assembly

The APOLLO is able to accommodate Elo analog resistive touch or Intelli (SAW) touch or MicroTocu capacitive touchscreen. PLEASE NOTE THAT WHEN DIFFERENT TOUCH MODULE IS

INSTALLED, DIFFERENT TOUCHSCREEN METAL BRACKETS ARE NEEDED. YOU CAN NOT REPLACE ONE TYPE OF TOUCH PANEL WITH THE OTHER

WITHOUT CHANGING THE TOUCHSCREEN METAL BRACKETS USED TO HOLD

THE TOUCH PANEL TO THE FRONT BEZEL.

The following steps illustrate the ways to assemble the toucshcreen to the front bezel.

1. There are 4 rubber slips with one-side taped with glue. Glue the 4 slips to the gutters located at the reverse side of the plastic front bezel. The 4 rubber slips act as cushions to absorb the pressure when the touchscreen is fixed to the front bezel with screws. 2. There are 4 metal brackets used to fix the touchscreen to the front bezel. The metal brackets have to be taped with soft tapes as shown on Figure 5-6 (7) & (8).

3. Then, fix the touchscreen to the front bezel with the 4 metal brackets with screws. The soft tapes are used to absorb the pressure when the metal brackets fix the touchscreen to the front bezel.

If no toushcreen is installed, there are two options. One is to put a resilient glass instead. The advantage of putting a resilient glass is to protect the LCD panel.

The other option is to fix 4 bronze sticks (5 mm) to the LCD bracket to push the LCD panel forward to make up the gap between the LCD and the front bezel. But when using this way, two screw holes on the front bezel need to be cut to prevent LCD mechanism interference to the front bezel.

Apollo Commercial Clothes Dryer (150 III) — 5.7. Touchscreen or Front Bezel Assembly diagram (page 70)
Fig. 29 · 5.7. Touchscreen or Front Bezel Assembly
Page 71 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 71 · click to enlarge
Page 71
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 71)
Fig. 30 · 5.6. HDD Module Assembly

12.1"ELO TOUCH „q“ý ƒ¡ ELO 12.1"À£ –ł (¥“ ¥k)

F IGURE 5-6APOLLO 120 F RONT BEZEL ASSEMBLY
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 71)
Fig. 31 · 5.6. HDD Module Assembly

15.0"ELO TOUCH „q“ý ƒ¡ ELO 15.0"À£ –ł (¥“ )

“w·Ö À£ –ł 250*5*1 mm ⁄W ⁄UPE “w·Ö À£ –ł 185*5*1 mm ¥“ ¥kPE ELO 15.0"À£ –ł (¥k)

F IGURE 5-7APOLLO 120 F RONT BEZEL ASSEMBLY
Page 72 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.8. LCD Module Assembly
Page 72 · click to enlarge
Page 72

5.8. LCD Module Assembly

Figure 5-8 and 5-9 illustrate the way to assemble the APOLLO’s LCD module.

The LCD does not fix to the main system directly. Rather, it is to be fixed to a LCD holder, then to the main system. The assembly of APOLLO 120 LCD module slightly differs from that of APOLLO 150.

APOLLO 120 1. Refer to Figure 5-8. There are two LCD brackets (2) & (3) used to fix to the LCD panel (1) to the LCD holder (11) from the up & down sides. 2. Fix the LCD panel to the LCD holder with four PMS 3*8 screws.

3. The standard LCD used in APOLLO 120 is SANYO MXS121022010 or its equivalent. It is a TTL interface LCD. The LCD cable (4) is a DF9-41S to 2*25-pin cable with around 35 cm in its length. Insert the 41-pin end into the opening at the rear side of the LCD holder and have it firmly plugged to the 41-pin connector at the rear side of the LCD panel.
4. Attach the insulator (10) to the invertor (9). 5. The invertor cable (8) is a 4-pin to 4-pin cable with wafer connectors at both sides. Connect the one end to invertor first. The other end is for later connection to the INV1 on the motherboard.
6. Connect the pink-white high voltage wires from the LCD to the invertor.
7. The invertor module is to be fixed at the right middle side of the LCD holder with the up side down.
8. For APOLLO 120, the IR/LED board (2) is to be fixed to the lower side of the LCD holder. 9. The two speakers are to be fixed to the right and left sides of the IR/LED board. The speaker wires are to be connected to the 2-pin header on the IR/LED board.
Page 73 of the Apollo Commercial Clothes Dryer (150 III) user manual — APOLLO 150
Page 73 · click to enlarge
Page 73

APOLLO 150

1. Refer to Figure 5-9. The standard LCD used in APOLLO 150 is either 15.1” TTL LG 151X2 or 15” LVDS Chi Mei M150X3-L01 or their equivalent. The assembly of TTL LCD differs from that of the LVDS LCD.

2. Fix the LCD panel (1) to the LCD holder (9) with four PMS 3*8 screws. 3. For the TTL LCD, LM151X2 or its equivalent, the LCD cable (2) is a DF9-41S to 2*25-pin cable with around 35 cm in its length. Insert the 41-pin end into the opening at the rear side of the LCD holder and have it firmly plugged to the 41-pin connector at the rear side of the LCD panel. The other end is for later connection to the LCD1 on the motherboard. 4. For the LVDS LCD, M150X3-L01 or its equivalent, as the motherboard’s display is a TTL controller, to connect the onboard LCD controller to the LVDS LCD, an LVDS transceiver board is needed. 5. The APOLLO 150’s LVDS transceiver board is to be fixed at the system chassis between the touch controller and HDD.

6. The LCD cable for the LVDS LCD is a DF14-20 to DF14-20 cable with around 35 cm in its length. Connect one end to the connector located at the rear side of the LCD panel with the other end going through the opening at the rear side of the LCD holder for later connection to the LVDS1 on the LVDS board.
7. There is a 2*25-pin to 2*25-pin LVDS cable. Plug one end to the LCD1 on the LVDS board with the other end connected to the 2*25-pin header connector, LCD1 on the motherboard.
8. Attach the insulator (6) to the invertor (7).
9. The invertor cable (8) for APOLLO 150 is a 7-pin to 4-pin cable with wafer connectors at both sides. Connect the 7-pin end to the invertor first. The other end is for later connection to the INV1 on the motherboard.
Page 74 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 74 · click to enlarge
Page 74
10. Connect the pink-white high voltage wires from the LCD to the invertor. 11. The invertor module is to be fixed at the reverse side of the LCD holder after the LCD module is to be installed to the system.
12. For APOLLO 150, fix 6 bronze sticks (15 mm) to the lower sides of the LCD holder. Fix the IR/LED board to the LCD holder with two 3*6 screws.
13. The two speakers (Fig. 5-8 (6)) are to be fixed to the right and left sides of the IR/LED board. The speaker wires are to be connected to the 2-pin header on the IR/LED board.
Page 75 of the Apollo Commercial Clothes Dryer (150 III) user manual — F IGURE 5-9: APOLLO 150 LCD MODULE ASSEMBLY
Page 75 · click to enlarge
Page 75
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 75)
Fig. 32 · 5.6. HDD Module Assembly

12"LCD'T'w‹[⁄U 12"LCD 'T'w‹[⁄W LCD CABLE DFP41-50P 330mm MODULE APOLLO LED A1.0 SPEAKER LED CABLE 120mm

12"INVERTER MOLEX P-HRS4P 220mm INVERTER 12.1"TORISAN 12"INVERTERµ· ‰t⁄ø 120*26.7*0.35 12"«e¯K“O

F IGURE 5-8: APOLLO 120 LCD MODULE ASSEMBLY

Apollo Commercial Clothes Dryer (150 III) — F IGURE 5-8: APOLLO 120 LCD MODULE ASSEMBLY diagram (page 75)
Fig. 33

LCD CABLE DFP41-50P 330mm MODULE APOLLO LED A1.0 SPEAKER LED CABLE 120mm 15"µ· ‰t⁄ø 168*39*0.35 INVERTER 15"

F IGURE 5-9: APOLLO 150 LCD MODULE ASSEMBLY

Page 76 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 76 · click to enlarge
Page 76

After finishing the LCD module installation, the module is to be assembled to the front bezel module, then to the chassis with the motherboard and touch controller already on.

1. Use special air blower to blow any dust between the LCD and touchscreen before the two modules are assembled together. Retain the LCD module and the front bezel module together with 8 FMS 3*6 screws. 2. Install the whole front bezel module with LCD already on to the system chassis with the motherboard, touchscreen controller and HDD module already on. 3. The LCD cable is already at the rear side of the LCD holder through the cutout. Make sure the other end is to go through the rectangle opening at the rear side of the system chassis and have it connected to LCD connector, LCD1 on the motherboard. SPECIAL ATTENTION NEEDS TO BE PAID WHEN PLUGGING THE LVDS OR LCD CABLE TO THE LCD HEADER CONNECTOR ON THE MOTHERBOARD. MAKE SURE PIN 1 OF THE ONBOARD LCD CONNECTOR MATCH PIN 1 OF

THE CABLE. ANY WRONG PLUGGING OR SHIFTED PLUGGING WILL

DAMAGE THE LCD PANEL OR LEAD TO MAL-FUNCTION.

4. The touchscreen 5-pin flat cable should go through the rectangle opening at the left side of the LCD holder, then get into the chassis from the oval-shape cutout at the left side of the chassis. Connect this cable to the touchcreen controller. Connect the other end of the touch power cable to the onboard PWR 1.
5. For APOLLO 150, the invertor now is to be fixed to the left outward side of the chassis and have the invertor cable go into the chassis through the cutout. Connect the other end of the invertor cable to the motherboard’s INV1.
6. Connect the other end of the IR/LED cable to the IR/LED board.
Page 77 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.9.1. Internal CD-ROM/FDD Assembly
Page 77 · click to enlarge
Page 77

5.9. CD-ROM/DVD-ROM/FDD Module Assembly

The APOLLO provides enough space to accommodate a CD-ROM or CD-RW or DVD-ROM and a floppy disk drive. The CD-ROM or DVD-ROM drive used in the APOLLO 120/150 is not the common 5.25” drive seen in computer stores. Rather, it is a slim type drive widely used in notebook computers.

The APOLLO 120/150 can connect to an external floppy disk drive or an internal slim type floppy disk drive, depending on the system requirement.

Please note that either an external floppy disk drive or internal floppy disk drive can be used.

5.9.1. Internal CD-ROM/FDD Assembly

The following steps show the ways to install an internal CD-ROM or DVD-ROM and floppy disk drive.

1. Make the chassis’ lower side near you. Now, from your point of view, the CD-ROM/FDD module is to be installed on the left side of the chassis. 2. Refer to Figure 5-10. Attach the CD-ROM board (4) to the slim CD-ROM (2) and fix them together with 2 screws. P LEASE NOTE THAT THE 2 SCREWS NEED TO BE INCASED WITH 2

PLASTIC WASHERS (3) TO PREVENT SHORT CIRCUITRY. 3. Insert the CD-ROM module to the CD-ROM/FDD bracket (9) and fix them together with 2 screws.

4. There is a 40-pin CD-ROM cable. Connect one end to the CD-ROM board.
5. Attach one end of the 26-pin FDD flat cable (8) to the slim floppy disk drive (7) first.
6. Insert the FDD module to the CD-ROM/FDD bracket and fix them together with 2 FMS screws. 7. There is a small metal bracket (1) used to firmly fix the CD-ROM and FDD modules to the CD-ROM/FDD bracket. This small bracket is to prevent the CD-ROM/FDD from moving when installed to the FDD/CD-ROM bracket.
Page 78 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 78 · click to enlarge
Page 78
8. Connect the 40-pin end of the CD-ROM cable to the motherboard IDE 2 connector. 9. There is a 4-pin CD audio-in cable to be plugged to J2 on the motherboard. Connect the other end of the CD-Audio cable (6) to the 4-pin black pin connector on the CD-ROM board. 10. Connect the other end of the FDD cable to the FDD1 on the motherboard.
11. Fix the whole unit to the chassis and fix them together with 3 FMS 3*5 screws.
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 78)
Fig. 34 · 5.6. HDD Module Assembly

slim CDROM CDROM ¶¡ „j‹W 2.5mm MODULE CDROM-FDD CDROM CABLE 150mm SOUND CABLE P/H 2.54 120mm slim FDD FDD ‡n–˘ 26pin 130mm ”ˇ ¾÷ ‹[

Page 79 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.9.2. External FDD Connection
Page 79 · click to enlarge
Page 79

5.9.2. External FDD Connection

Apollo Commercial Clothes Dryer (150 III) — 5.9.2. External FDD Connection diagram (page 79)
Fig. 35 · 5.9.2. External FDD Connection
1. Use the provided 15-34 pin FDD cable (see below figure) to connect to the system's 15-pin FDD D-sub connector located at the rear side of the cover.
2. Connect the other end (34 pin) of the FDD cable to a standard 3.5” FDD. Match pin 1 of the FDD and pin 1 of the cable. 3. To drive the floppy disk drive, it will need 5V power. Connect the provided FDD power cable to the floppy disk drive to the +5V/12V DC-out connector to obtain 5V power for the device.

FDD cable

Page 80 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.10. Power Module Assembly
Page 80 · click to enlarge
Page 80

5.10. Power Module Assembly

The power supply is to be integrated with the power brackets before it is installed to the panel PC system. The following diagram shows the steps to assemble the ATX power module. For the specification of the power supply, please refer to APPENDIX.

1. Refer to Figure 5-11. Attach the power fix bracket (2) to the power supply (3) and fix them together with 2 FMS screws (3*5). This small bracket is used to prevent the power supply from moving around in the power bracket.
2. Insert the power supply to power bracket (1) and fix them together with four 3*5 screws. 3. Manage all the power cables from the power supply properly. 4. Insert the power switch (4) to power bracket (5). The other end of the switch cable is to be connected to the 2-pin POWER ON switch, SW1 on the motherboard.
5. Plug the ATX power cable to the ATX power connector, PWR 3 on the motherboard. 6. Connect the big 4P end of the power cable to the HDD. 7. Connect the small 4P end the CD-ROM board.
8. The power module is to be installed to the system right on the top of the CD-ROM/FDD module.
Page 81 of the Apollo Commercial Clothes Dryer (150 III) user manual — F IGURE 5-11: APOLLO AC P OWER MODULE
Page 81 · click to enlarge
Page 81
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 81)
Fig. 36 · 5.6. HDD Module Assembly

The power cable coming out from the cutout and connected to the MB’s ATX power connector.

F IGURE 5-11: APOLLO AC P OWER MODULE

Page 82 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.11. Expansion Outlets & Riser Card Assembly
Page 82 · click to enlarge
Page 82

5.11. Expansion Outlets & Riser Card Assembly

The APOLLO 120/150 provides PCI/ISA expansion slots for system expansion. Via the specially designed riser card, the system can accommodate either two PCI or one PCI plus one ISA expansion cards; all the connectors of the expansion card will come out from the expansion outlet on the left side of the chassis for further cable connection. The expansion outlet bracket has to be installed to the system before plugging the riser card to the motherboard PCI/ISA expansion slot.

1. When the system is reverse with the rear side facing you and lower side near you, the expansion outlets are located at the right upper side of the chassis.
2. Install the expansion window (Fig. 5-1 (11)) to the chassis and fix them together with 2 FMS screws.
3. If no expansion card is plugged to the riser card, seal the expansion outlets with the 2 metal slips located inside the expansion outlet. 4. The riser card (8) is to be fixed with the metal bracket (9) with two FMS screws first. Then, plug the riser card to the onboard PCI/ISA slot. Make sure the riser card is firmly plugged to the motherboard to prevent any bad connection.

Due to the internal space limitation, the expansion card can not exceed 190*120 (L*W) mm if no internal FDD is installed. However if an internal FDD is installed, the ISA card can not exceed 170*120 mm.

Page 83 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.12. Back Panel Assembly
Page 83 · click to enlarge
Page 83

5.12. Back Panel Assembly

The back panel module is the last module to be integrated to the APOLLO main system before the plastic housing is to be installed to the system. 1. On the I/O board, there are 6 D-SUB connectors with 2 bronze sticks on each side. Remove the 12 bronze sticks. 2. Insert the I/O board to the I/O bracket (2) and fix them together with the 12 bronze sticks. Fix them again with 2 screws on the other side.

3. Fix the complete I/O module to the metal back panel (1) five FMS 3*5 screws. 4. Connect one end of the 2 68-pin SCSI cables (Fig. 5-12 (4)) to the I/O board (3). Via the 2 SCSI cables, all the onboard I/O signals are converted to the I/O board for device cable connection. 5. Connect the other end of the two SCSI cables to the SCSI 1 and SCSI 2 connectors on the motherboard.
6. Fix the back panel module to the main system. 7. Fix a stand bracket at the bottom side of the chassis with 2 screws.
Apollo Commercial Clothes Dryer (150 III) — 5.12. Back Panel Assembly diagram (page 83)
Fig. 37 · 5.12. Back Panel Assembly

I/O »\ MODULE APOLLO IO A1.0 SCSI 68P-SCSI 68P L:180mm

Page 84 of the Apollo Commercial Clothes Dryer (150 III) user manual — F IGURE 5-13: APOLLO PEDESTAL ASSEMBLY
Page 84 · click to enlarge
Page 84

5.13. Stand Module Assembly

The APOLLO system comes with a versatile stand composing of one big pedestal and one set of cable management covers. The following figure illustrates the steps to make up the APOLLO stand.

1. Refer to Fig. 5-13. Fix the two hinges to the hinge bracket (5). Then fix the unit to the metal base (1). Please note that the two hinges are different. The right side is used to fix the hinge knob. Note that there are two avocado-shape holes on the metal base. The two avocado holes are used to fix the stand to the table for special application. 2. Insert the stand bottom cover (4) to the hinge module and fix them together with four FMS 3*6 screws.

3. Fix the plastic upper cover (6) to the hinge bracket with 2 screws.
4. Insert the whole base unit to the base plastic cover (7) and fix them together with screws to make the complete unit a pedestal. 5. Insert the hinge knob (2) to the pedestal.
Apollo Commercial Clothes Dryer (150 III) — 5.13. Stand Module Assembly diagram (page 84)
Fig. 38 · 5.13. Stand Module Assembly

HINGE (¥“ ) with LOCK HINGE (¥k) APOLLO 120/150 ´à ¶b›× „¢ ⁄U»\

´à ¶b⁄ä ‹[ APOLLO 120/150 ´à ¶b›× „¢ ⁄W »\

F IGURE 5-13: APOLLO PEDESTAL ASSEMBLY

Page 85 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 85 · click to enlarge
Page 85

To assemble the stand module (Fig. 5-14 (1)) to the main system (2), simply tighten the two units together with 4 screws from the base. Then, install the two base back covers (4 & 5) to the unit as shown below. There is an additional knob in the accessory. If touchscreen is to be used with the system, it is suggested that the additional knob is to be assembled to the system to prevent the system from wobbling. By swiveling the knob and pulling the base up and down, the angle can be fixed at 45 to 900.

Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 85)
Fig. 39 · 5.6. HDD Module Assembly

¥D¯Ø †Õ «~ APOLLO 120/150 '‡ fiy›× „¢ ⁄W »\ APOLLO 120/150 '‡ fiy›× „¢ ⁄U»\

F IGURE 5-14APOLLO STAND TO MAIN SYSTEM ASSEMBLY
Page 86 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 86 · click to enlarge
Page 86
Page 86 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 87 of the Apollo Commercial Clothes Dryer (150 III) user manual — 6. S YSTEM MOTHERBOARD & I/O B OARD
Page 87 · click to enlarge
Page 87

6. S YSTEM MOTHERBOARD & I/O B OARD

The system controller used in the APOLLO III system is a special-design Celeron/Pentium ® III multimedia motherboard. All the onboard signal is connected to an I/O board via 2 SCSI cables for external device connection. This chapter provides jumper definition and connector signal of the motherboard and the I/O board.

Page 88 of the Apollo Commercial Clothes Dryer (150 III) user manual — 6.1.1. General Information
Page 88 · click to enlarge
Page 88

6.1. APOLLO III Motherboard

This section provides background information and detail specification on the APOLLO 120/150 III system engine, PC 610. Sections include: ² General Information ² Features ² Specification ² Board placement & Dimension

6.1.1. General Information

The PC 610 is an Intel Celeron/Pentium III (Socket 370) multimedia ATX motherboard with LCD/VGA controller, Ethernet 100/10, AC97 sound, and IDE flash disk. By integrating single chip, SiS630ST, the PC 610 provides a high performance/low cost desktop solution. Highly integrated, the PC 610 can adapt Intel Celeron (66/100MHz) and Pentium III (100/133MHz) CPU. Onboard features include four serial ports, one multi–mode Parallel ports, a floppy drive controller and a PS/2 keyboard PS/2 mouse interface. The built-in high speed PCI IDE controller supports both PIO and ATA 100 mode. Up to four IDE devices can be connected, including large hard disks, CD-ROM drives and other IDE devices. The full PC functionality coupled with its multi-I/Os stand ready to accommodate a wide range of PC peripherals. Compact in size and with its highly integrated multimedia and networking functions, the PC 610 is the most powerful PC engine to build any small footprint all-in-one PC system for integration into any space-constricted embedded applications.

Fully configurable and with its modular design, the PC 610 is an ideal platform for any consumer computing applications where space is a premium.

Page 89 of the Apollo Commercial Clothes Dryer (150 III) user manual — 6.1.2. Specifications
Page 89 · click to enlarge
Page 89

6.1.2. Specifications

PC 610Multimedia Intel Celeron/Pentium III Motherboard

with XGA, LCD, Dual display, Ethernet & Audio Interface u CPU: Intel Socket 370

  • Intel Pentium III FCPGA 1GHz/133MHz
  • Intel Pentium III FCPGA 650-933/133MHz
  • Intel Pentium III FCPGA 500E-850E/100MHz
  • Intel Celeron FCPGA 800MHz-1.10GHz/100MHz
  • Intel Celeron FCPGA 533AMHz-766MHz/66MHz
  • Intel Celeron PPGA 300A-533MHz/66MHz u Main Chipset : SiS630ST u System BIOS : Award PnP Flash BIOS u System Memory : 1 x 168 pin DIMM sockets

supporting SDRAM up to 512MB

u L2 CacheCPU built-in u Standard I/O
  • Serial ports x 4
  • Parallel port x 1
  • ATA 100/66 IDE x 2: supports up to 4 IDE devices
  • FDD x 1: supports up to 2 floppy disk drives
  • PS/2 Keyboard Interface x 1
  • Internal Keyboard Interface x 1
  • PS/2 Mouse Interface x 1
  • USB Interface x 4 supporting USB 1.0 devices u IrDA: 5-pin header with CIR support u Ethernet
  • 100/10 Base-T Ethernet
  • Support WAKE-ON-LAN
Page 90 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 90 · click to enlarge
Page 90
  • LCD controller
  • Integrated 2D/3D graphics engine, 4X AGP
  • Share system memory architecture able to utilize the display memory size up to 64MB
  • Maximum resolution for video chipset: 640x480, 800x600, 1024x768, 1280x1024, 1600x1200, 1920x1200, True-color
  • Supporting LCD/VGA dual display mode (under Windows 98, Windows ME and Windows XP)
  • Full duplex and independent sample rate converter for audio recording & playback
  • Supports Microsoft DirectSound
  • 3D positional audio effects
  • Hi-performance, mixed-signal, stereo
  • MIC-In, Speaker-Out, Line-In
  • Pin header for CD-audio in u Hardware Monitor
  • Monitoring processor & system
  • Monitoring 5VSB, VBAT, 1.5V, 3.3V, +5V, +12V, -12V, and processor voltages
  • Monitoring processor, chassis fan speeds
  • Controlling processor and chassis fan speed and failure alarm
  • Automatic fan on/off control
  • Read back capability that displays temperature, voltage and fan speed
  • Supporting Intel processor thermal diode output (real processor temperature)

u Expansion Bus: PCI/ISA x 1 u Power: ATX power u Dimension: 300*146 mm (L*W) Specifications are subject to change without notice.

u Display · u Audio Function

Page 91 of the Apollo Commercial Clothes Dryer (150 III) user manual — 6.1.3. Locating Jumpers & Connectors
Page 91 · click to enlarge
Page 91

6.1.3. Locating Jumpers & Connectors

The following figure helps you to locate the jumpers and

connectors on the motherboard.

Apollo Commercial Clothes Dryer (150 III) — 6.1.3. Locating Jumpers & Connectors diagram (page 91)
Fig. 40 · 6.1.3. Locating Jumpers & Connectors
Page 92 of the Apollo Commercial Clothes Dryer (150 III) user manual — 6.1.4. Jumpers & Jumper Setting
Page 92 · click to enlarge
Page 92

6.1.4. Jumpers & Jumper Setting

The table below lists the function of each jumper. The related jumper settings are shown in the coming sections.

JP1 DOC Address Selection

JP5 COM2 RS-232/422/485 selection

JP6 COM2 RS-232/422/485 selection

JP7 COM2 RS-232/422/485 selection

JP8 COM2 RS-232/422/485 selection

JP9 COM2 RS-232/422/485 selection

JP10 COM2 RS-232/422/485 selection

Jumper Description · JP2 Clear CMOS

Page 93 of the Apollo Commercial Clothes Dryer (150 III) user manual — 1-2 D000
Page 93 · click to enlarge
Page 93

6.1.4.1. DOC 2000 Address Setting (JP1)

1-2 D000

3-4 D800

6.1.4.2. Clear CMOS (JP2)

6.1.4.3. COM 2 232/422/485 Setting (JP5,6,7,8,9 & 10)

COM 2 is a RS-232/422/485 serial port. JP5, 6, 7, 8, 9 and JP10 determine the specific port type.

Apollo Commercial Clothes Dryer (150 III) — 1-2 D000 diagram (page 93)
Fig. 41

1-2 Clear CMOS · 3-4 Normal

Page 94 of the Apollo Commercial Clothes Dryer (150 III) user manual — 6.1.5. Connectors & Pin Assignment
Page 94 · click to enlarge
Page 94

6.1.5. Connectors & Pin Assignment

The table below lists the function of each connector on the PC 610. Their corresponding pin assignments will be shown in the following sections.

Apollo Commercial Clothes Dryer (150 III) — 6.1.5. Connectors & Pin Assignment diagram (page 94)
Fig. 42 · 6.1.5. Connectors & Pin Assignment
Page 95 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 95 · click to enlarge
Page 95
6.1.5.1. PWR3ATX Power connector

PWR 3 is a standard ATX power connector. This connector is provided to connect to an ATX power supply. The plug of the power supply will only insert in one orientation due to the different hole size. Find the proper orientation and push down the power connector firmly to make sure the pins are aligned. Its pin assignments are listed below:

Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 95)
Fig. 43 · 5.6. HDD Module Assembly
Page 96 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 96 · click to enlarge
Page 96
6.1.5.2. J2CD Audio IN
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 96)
Fig. 44 · 5.6. HDD Module Assembly
6.1.5.3. J7HDD LED & ACPI LED & SMI
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 96)
Fig. 45 · 5.6. HDD Module Assembly
6.1.5.4. J8IR / CIR Connector
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 96)
Fig. 46 · 5.6. HDD Module Assembly
Page 97 of the Apollo Commercial Clothes Dryer (150 III) user manual — 2 GND
Page 97 · click to enlarge
Page 97
6.1.5.5. J9Power LED & KB
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 97)
Fig. 47 · 5.6. HDD Module Assembly
6.1.5.6. SW1ATX Power ON/OFF & Reset

2 GND

6.1.5.7. COM3

COM 3 is an internal RS-232 reserved for touchscreen. Its corresponding pin assignment is listed as below;

Apollo Commercial Clothes Dryer (150 III) — 2 GND diagram (page 97)
Fig. 48

Pin # Signal · 1 Power ON/OFF

Page 98 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 98 · click to enlarge
Page 98
6.1.5.8. LCD1LCD Connector
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 98)
Fig. 49 · 5.6. HDD Module Assembly
Page 99 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 99 · click to enlarge
Page 99
6.1.5.9. INV1LCD Inverter Connector
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 99)
Fig. 50 · 5.6. HDD Module Assembly
6.1.5.10. FDD1FDD connector
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 99)
Fig. 51 · 5.6. HDD Module Assembly
Page 100 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 100 · click to enlarge
Page 100
6.1.5.11. IDE1/IDE2Primary/Secondary HDD

The PC 610 provides 2 sets of 40-pin IDE connectors. The built-in high speed PCI IDE controller supports both PIO and ATA 100 mode. Up to four IDE devices can be connected, including large hard disks, CD-ROM drives and other IDE devices. Their corresponding pin assignments are listed below;

Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 100)
Fig. 52 · 5.6. HDD Module Assembly
Page 103 of the Apollo Commercial Clothes Dryer (150 III) user manual — A1
Page 103 · click to enlarge
Page 103
6.1.5.14. CN4PCI/ISA Expansion Slot

The PC 610 provides an ISA/PCI slot for ISA and PCI device expansion.

Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 103)
Fig. 53 · 5.6. HDD Module Assembly

A1

A2

A3

A4

A5

A6

A7

A31

Page 104 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 104 · click to enlarge
Page 104
CN4PCI/ISA Slot Connector Pin Assignment
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 104)
Fig. 54 · 5.6. HDD Module Assembly

F3 INTB B3 VCC E3 INTC A3 SD6

F5 VCC B5 -5V E5 VCC A5 SD4

F7 VCC B7 -12V E7 VCC A7 SD2

Page 105 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 105 · click to enlarge
Page 105
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 105)
Fig. 55 · 5.6. HDD Module Assembly

F29 DEVSEL B29 VCC E29 CBE2 A29 SA2

H16 VCC D16 VCC G16 VCC C16 SD13

H17 VCC D17 MASTER G17 VCC C17 SD14

To continue…

Page 106 of the Apollo Commercial Clothes Dryer (150 III) user manual — 6.2.1. Locating Jumpers & Connectors
Page 106 · click to enlarge
Page 106

6.2. APOLLO III I/O Board

All the onboard I/O signal of the APOLLO motherboard is connected to an I/O board via 2 SCSI cables for external device connection. This section provides jumper definition and connector signal of the I/O board.

6.2.1. Locating Jumpers & Connectors

The following figure helps you to locate the jumpers and connectors on the motherboard.

Apollo Commercial Clothes Dryer (150 III) — 6.2.1. Locating Jumpers & Connectors diagram (page 106)
Fig. 56 · 6.2.1. Locating Jumpers & Connectors
Page 107 of the Apollo Commercial Clothes Dryer (150 III) user manual — RI 5V 12V
Page 107 · click to enlarge
Page 107

6.2.2. Jumpers & Jumper Setting

The table below lists the function of each jumper. The related jumper settings are shown in the coming sections.

JP1 Keyboard Connector power selection

JP2 COM1 Pin 9 power selection

JP3 COM2 Pin 9 power selection

JP4 COM4 Pin 9 power selection

6.2.2.1. JP1Keyboard Power Select

1-2 SB5V

2-3 +5V

6.2.2.2. COM port Power Selection

JP1: COM1 Pin 9 Power selection JP2: COM2 Pin 9 Power selection JP4: COM4 Pin 9 Power selection

RI 5V 12V

1-2 3-4 5-6

Page 108 of the Apollo Commercial Clothes Dryer (150 III) user manual — 6.2.3. Connectors & Pin Assignment
Page 108 · click to enlarge
Page 108

6.2.3. Connectors & Pin Assignment

The table below lists the function of each connector on the I/O board. Their corresponding pin assignments will be shown in the following sections.

Apollo Commercial Clothes Dryer (150 III) — 6.2.3. Connectors & Pin Assignment diagram (page 108)
Fig. 57 · 6.2.3. Connectors & Pin Assignment
Page 109 of the Apollo Commercial Clothes Dryer (150 III) user manual — 6.2.3.3. COM1, COM2, COM4: DB-9
Page 109 · click to enlarge
Page 109
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 109)
Fig. 58 · 5.6. HDD Module Assembly
6.2.3.2. KBMSPS/2 Mouse
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 109)
Fig. 59 · 5.6. HDD Module Assembly

6.2.3.3. COM1, COM2, COM4: DB-9

Apollo Commercial Clothes Dryer (150 III) — 6.2.3.3. COM1, COM2, COM4: DB-9 diagram (page 109)
Fig. 60
Page 110 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 110 · click to enlarge
Page 110
6.2.3.4. CN1DC Power Output
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 110)
Fig. 61 · 5.6. HDD Module Assembly
6.2.3.5. LPT1D-SUB-25 Parallel Port
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 110)
Fig. 62 · 5.6. HDD Module Assembly
6.2.3.6. CRT1VGA (D-SUB 15 Pin)
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 110)
Fig. 63 · 5.6. HDD Module Assembly

Pin # Signal Pin # Signal Pin # Signal

Page 111 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 111 · click to enlarge
Page 111
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 111)
Fig. 64 · 5.6. HDD Module Assembly

Pin # Signal Pin # Signal Pin # Signal

6.2.3.8. J11USB 1 , USB2 Connector
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 111)
Fig. 65 · 5.6. HDD Module Assembly
6.2.3.9. DIO1RJ-11 Connector
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 111)
Fig. 66 · 5.6. HDD Module Assembly
6.2.3.10. LAN1RJ-45 Ethernet Connector
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 111)
Fig. 67 · 5.6. HDD Module Assembly
Page 112 of the Apollo Commercial Clothes Dryer (150 III) user manual — 6.2.3.13. SPK 1
Page 112 · click to enlarge
Page 112

6.2.3.11. MIC1

Apollo Commercial Clothes Dryer (150 III) — 6.2.3.11. MIC1 diagram (page 112)
Fig. 68

6.2.3.12. LINE 1

Apollo Commercial Clothes Dryer (150 III) — 6.2.3.12. LINE 1 diagram (page 112)
Fig. 69

6.2.3.13. SPK 1

Apollo Commercial Clothes Dryer (150 III) — 6.2.3.13. SPK 1 diagram (page 112)
Fig. 70
Page 115 of the Apollo Commercial Clothes Dryer (150 III) user manual — 7. A WARD BIOS S ETUP
Page 115 · click to enlarge
Page 115

7. A WARD BIOS S ETUP

The chapter describes how to set up BIOS configuration.

Page 116 of the Apollo Commercial Clothes Dryer (150 III) user manual — 7.1. Award BIOS
Page 116 · click to enlarge
Page 116

7.1. Award BIOS

The Award BIOS ROM builds in a setup program, which allows the users to modify the basic system configuration such as the current date and time or the type of peripheral devices attached to the computer.

Under the following conditions, the CMOS settings are to be changed¡ G

1. The system is starting for the first time 2. The hardware devices attached to the systems have been changed 3. The CMOS memory has lost power and the configuration information has been erased. The BIOS setup program is stored in ROM, which can be accessed by pressing key on the keyboard immediately when the system is powered on.

In order to retain the specified setup information when the system power is turned off, the system setup information is stored in a battery-backed CMOS RAM. The battery is to ensure the settings will not be erased when the computer is turned off or reset. When the computer is powered on again, the system will read the settings stored in the CMOS RAM and compare them to the equipment check conducted during the power on self test (POST). If any error or mismatch occurs, an error message will be shown on the screen and the computer will be prompted to run the setup program.

Page 117 of the Apollo Commercial Clothes Dryer (150 III) user manual — 7.2. Control Key Definition
Page 117 · click to enlarge
Page 117

7.2. Control Key Definition

Up arrow Move to previous item Down arrow

Move to next item

Left arrow Move to the item in the left hand Right arrow

Move to the item in the right hand

ESC key Main Menu - Quit and not save changes into CMOS Status Page Setup Menu and Option Page Setup Menu - Exit current page and return to Main Menu PgUp key Increase the numeric value or make changes PgDn key Decrease the numeric value or make changes F1 key General help, only for Status Page Setup Menu and Option Page Setup Menu F2 key Change color from total 16 colors F3 key Reserved F4 key Reserved F5 key Restore the previous CMOS value from CMOS, only for Option Page Setup Menu F6 key Load the default CMOS value from BIOS default table, only for Option Page Setup Menu F7 key Load the default F8 key Reserved F9 key Reserved F10 key Save all the CMOS changes, only for Main Menu

Page 118 of the Apollo Commercial Clothes Dryer (150 III) user manual — 7.4. AWARD BIOS Setup
Page 118 · click to enlarge
Page 118

7.3. Getting Help

7.3.1. Main Menu

The on-line description of the highlighted setup function is displayed at the bottom of the screen. Press to pop up a small help window that describes the appropriate keys to use and the possible selections for the highlighted item. To exit the Help Window, press .

7.4. AWARD BIOS Setup

7.4.1. AWARD BIOS Setup Main Menu

Power on the computer and press immediately to run the AWARD BIOS setup. The setup main menu will appear on the screen;

CMOS Setup Utility – Copyright (C) 1984-200 Award Software

Ø Standard CMOS Features

Ø Advanced BOIS Features

Ø Advanced Chipset Features

Ø Power Management Setup

Save & Exit Setup

Ø PC Health Status

EscQuit F9 : Menu in BIOS : Select Item
F10Save & Exit Setup

Time, Date, Hard Disk Type …

Use the arrow keys to move among the items and press to enter the sub-menu.

Show 7 more labels / short text on this page
Ø Frequency/Voltage Control · Load Fail-Safe Defaults · Load Optimized Defaults · Ø Integrated Peripherals · Set Password · Ø PnP/PCI Configuration · Exit Without Saving
Page 119 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 119 · click to enlarge
Page 119

u STANDARD CMOS SETUP: This setup page includes all the

items in standard compatible BIOS.

u ADVANCED BIOS FEATURES: This setup page includes all

the items of Award special enhanced features.

u ADVANCED CHIPSET FEATURES: This setup page includes

all the items of chipset special features.

u I NTEGRATED P ERIPHERALSThis setup page includes all

onboard peripherals.

u POWER MANAGEMENT SETUP: This setup page includes all

the items of Green function features.

u PNP/PCI CONFIGURATION: This setup page includes all

the configurations of PCI & PnP ISA resources.

u PC HEALTH STATUS: This setup page auto detects the

temperature, voltage and fan speed.

u FREQUENCY/VOLTAGE CONTROL: This setup page includes

the CPU/SDRAM/PCI frequency setting

u LOAD FAIL-SAFE DEFAULTS: BIOS Defaults indicates the

most appropriate value of the system parameters that the system would be in safe configuration.

u LOAD OPTIMIZED DEFAULTS: Setup Defaults indicates the

value of the system parameters that the system would be in the best performance configuration.

u S ET P ASSWORDChange, set, or disable password. It

allows you to limit access to the system and Setup, or just to Setup.

u SAVE & EXIT SETUP: Save CMOS value settings to CMOS

and exit setup.

u E XIT WITHOUT SAVINGAbandon all CMOS value changes

and exit setup.

Page 120 of the Apollo Commercial Clothes Dryer (150 III) user manual — 7.4.2. Standard CMOS Features
Page 120 · click to enlarge
Page 120

7.4.2. Standard CMOS Features

If the STANDARD CMOS FEATURE is selected from the main menu, the screen below will appear. This menu allows the users to configure the system components such as date, time, hard disk drive, floppy disk drive and display type. The system BIOS will automatically detect the memory size; therefore no setting is needed.

CMOS Setup Utility – Copyright (C) 1984-200 Award Software

Item Help Date (mmdd: yy) Tue, Mar 6 2001
Time (hhmm: ss)

Ø IDE Primary Master

Change the day, month,

Ø IDE Primary Slave

Ø IDE Secondary Master

Ø IDE Secondary Slave

Drive A (1.44M, 3.5 in.)

LCD Panel ID Select (Type 0)

Full Screen Function (Disable)

Halt On (All, But Keyboard)

Total Memory 65536K

: Move Enter: Select +/-/PU/PD: Value F10: Save

ESCExit F1: General Help F5: Previous Values F6: Fail-Safe Defaults F7: Optimized Defaults
Show 7 more labels / short text on this page
Standard CMOS Features · Menu Level · year and century · Drive B (None) · Video (EGA/VGA) · Base Memory 640K · Extended Memory 64448K
Page 121 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 121 · click to enlarge
Page 121

u DATE The date format is , .

day The day, from Sun to Sat, determined by the BIOS and is display-only month The month, Jan. through Dec. date The date, from 1 to 31 (or the maximum allowed in the month) year The year, from 1994 through 2079

u TIME The times format in . The time is calculated base on the 24-hour military-time clock. For example, 1 p.m. is 13:00:00.

u PRIMARY HDDS / SECONDARY HDDS The category identifies the types of hard disk from drive C to F that has been installed in the computer. There are two types: auto type, and user definable type. User type is user-definable; Auto type which will automatically detect HDD type. Note that the specifications of your drive must match with the drive table. The hard disk will not work properly if you enter improper information for this category. If you select User Type, related information will be asked to enter to the following items. Enter the information directly from the keyboard and press . Such information should be provided in the documentation form your hard disk vendor or the system manufacturer.

CYLS. Number of cylinders HEADS number of heads PRECOMP write precomp LANDZONE Landing zone SECTORS number of sectors

If a hard disk has not been installed select NONE and press .

Page 122 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 122 · click to enlarge
Page 122

u DRIVE A TYPE / DRIVE B TYPE

The category identifies the types of floppy disk drive A or drive B that has been installed in the computer.

None No floppy drive installed 360K, 5.25" 5.25 inch PC-type standard drive; 360K byte 1.2M, 5.25" 5.25 inch AT-type high-density drive; 1.2M bytes (3.5 inch when 3 Mode is Enabled). 720K, 3.5" 3.5 inch double-sided drive; 720K byte 1.44M, 3.5" 3.5 inch double-sided drive; 1.44M byte 2.88M, 3.5" 3.5 inch double-sided drive; 2.88M byte

u VIDEO The category selects the default video device Options: EGA/VGA/CGA40/CGA80/Mono u FULL SCREEN FUNCTION

Enable/Disable the full screen function u HALT ON The category determines whether the computer will stop if an error is detected during power up.

NO Errors The system boot will not stop for any error that may be detected All Errors Whenever the BIOS detects a non-fatal error the system will be stopped and you will be prompted All, But Keyboard The system boot will not stop for a

keyboard error; it will stop for all other errors All, But Diskette The system boot will not stop for a disk error; it will stop for all other errors All, But Disk/Key The system boot will not stop for a keyboard or disk error; it will stop for all other errors

Page 123 of the Apollo Commercial Clothes Dryer (150 III) user manual — 7.4.3. Advanced BIOS Features
Page 123 · click to enlarge
Page 123

7.4.3. Advanced BIOS Features

If the ADVANCED BIOS FEATURES option is selected from the main menu, the screen below will appear. The following sample screen consists of the default values for PC 610.

CMOS Setup Utility – Copyright (C) 1984-200 Award Software

Item Help Virus Warning (Disabled)

CPU Internal Cache (Enabled)

CPU L2 Cache ECC Checking (Enabled)

Allow you to choose the

Processor Number Feature (Enabled)

Quick Power On Self Test (Disabled)

features for IDE Hard

First Boot Device (Disabled)

Second Boot Device (HDD-0)

protection. If this

Third Boot Device (LS120)

function is enabled and

Boot Other Device (Enabled)

Swap Floppy Drive (Disabled)

write data into this

Boot up Floppy Seek (Enabled)

area, BIOS will show a

Boot up NumLock Status (ON)

Gate A20 Option (Fast)

the screen and alarm

Typematic Rate Setting (Disabled)

Typematic Rate (Chars/Sec) 6

Typematic Rate Delay (Msec) 250

OS Select For DRAM > 64MB (Non-OS2)

Report NO FDD for Win 95 (No)

Video BIOS Shadow (Enabled)

: Move Enter: Select +/-/PU/PD: Value F10: Save

ESCExit F1: General Help F5: Previous Values F6: Fail-Safe Defaults
F7Optimized Defaults
Show 8 more labels / short text on this page
Advanced BIOS Features · Menu Level · External Cache (Enabled) · VIRUS warning · Disk boot sector · someone attempt to · beep · Security Option (Setup)
Page 124 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 124 · click to enlarge
Page 124

u VIRUS WARNING

Allow you to choose the VIRUS Warning feature for IDE Hard Disk boot sector protection. If this function is enabled and someone attempt to write data into this area, BIOS will show a warning message on screen and alarm beep.

Enabled Activates automatically when the system boots up causing a warning message to appear when anything attempts to access the boot sector or hard disk partition table.

Disabled No warning message will appear when anything attempts to access the boot sector or hard disk partition table.

u CPU INTERNAL CACHE/EXTERNAL CACHE

These two categories speed up memory access. However, it depends on CPU/chipset design.

Enabled Enable cache Disabled Disable cache

u CPU L2 CACHE ECC CHECKING

This item allows you to enable/disable CPU L2 Cache ECC checking. The choice: Enabled & Disabled.

u PROCESSOR NUMBER FEATURE Some of the new generation of socket-370 processors are installed with a unique processor number. This number may be used for verification in Internet transactions and e-commerce. If you prefer not to use or distribute the unique processor number, use this item to suppress the processor number. The choice: Enabled & Disabled.

Page 125 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 125 · click to enlarge
Page 125

u QUICK POWER ON SELF TEST

This category speeds up Power On Self Test (POST) after you power up the computer. If it is set to Enable, BIOS will shorten or skip some check items during POST. Enabled Enable quick POST

u FIRST/SECOND/THIRD/OTHER BOOT DEVICE The BIOS attempts to load the operating system from the devices in the sequence selected in these items.

The Choice: Floppy, LS/ZIP, HDD, SCSI, CDROM & Disabled.

u SWAP FLOPPY DRIVE

If the system has two floppy drives, you can swap the logical drive name assignments.

The choice: Enabled & Disabled.

u BOOT UP FLOPPY SEEK Seeks disk drives during boot up. Disabling speeds boot up. The choice: Enabled & Disabled.

u BOOT UP NUMLOCK STATUS Select power on state for NumLock. The choice: Enabled & Disabled.

u GATE A20 OPTION

Select if chipset or keyboard controller should control GateA20.

Normal A pin in the keyboard controller controls GateA20 Fast Lets chipset control GateA20

u TYPEMATIC RATE SETTING

Key strokes repeat at a rate determined by the keyboard controller. When enabled, the typematic rate and typematic delay can be selected. The choice: Enabled & Disabled.

Disabled Normal POST

Page 126 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 126 · click to enlarge
Page 126

u TYPEMATIC RATE (CHARS/SEC)

Sets the number of times a second to repeat a key stroke when you hold the key down.

The choice: 6, 8, 10, 12, 15, 20, 24 & 30.

u Typematic Delay (Msec)

Sets the delay time after the key is held down before it begins to repeat the keystroke. The choice: 250, 500, 750 & 1000.

u SECURITY OPTION

Select whether the password is required every time the system boots or only when you enter setup.

System The system will not boot and access to Setup will be denied if the correct password is not entered at the prompt.

Setup The system will boot, but access to Setup will be denied if the correct password is not entered at the prompt. Note: To disable security, select PASSWORD SETTING at Main Menu and then you will be asked to enter password. Do not type anything and just press , it will disable security. Once the security is disabled, the system will boot and you can enter Setup freely.

u OS SELECT FOR DRAM > 64MB

Select the operating system that is running with greater than 64MB of RAM on the system. The choice: Non-OS2, OS2.

u REPORT NO FDD FOR WIN 95

Whether report no FDD for Win 95 or not. The choice: Yes & No.

u VIDEO BIOS SHADOW

This item allows the video BIOS to be copied to system memory for faster performance.

The choice: Enabled & Disabled.

Page 127 of the Apollo Commercial Clothes Dryer (150 III) user manual — 7.4.4. Advanced Chipset Features
Page 127 · click to enlarge
Page 127

7.4.4. Advanced Chipset Features

If the ADVAMCED CHIPSET FEATURES option is selected from the main menu, the screen below will appear. The following sample screen consists of the default values for PC 610.

CMOS Setup Utility – Copyright (C) 1984-200 Award Software

Item Help Ø Advanced DRAM Control 1 (Press Enter)

Ø Advanced DRAM Control 2 (Press Enter)

System BIOS Cacheable (Enabled)

Video RAM Cacheable (Enabled)

Memory Hole at 15M-16M (Disabled)

AGP Aperture Size (64MB)

Graphic Window WR Combine (Enabled)

Concurrent function (MEM) (Enabled)

Concurrent function (PCI) (Enabled)

CPU Pipeline Control (Enabled)

PCI Delay Transaction (Enabled)

Memory Parity Check (Enabled)

: Move Enter: Select +/-/PU/PD: Value F10: Save

ESCExit F1: General Help F5: Previous Values F6: Fail-Safe Defaults F7: Optimized Defaults

Advanced Chipset Features · Menu Level

Page 128 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 128 · click to enlarge
Page 128

u ADVANCED DRAM CONTROL 1 / 2 SETTINGS

The first chipset settings deal with CPU access to dynamic random access memory (DRAM). The default timings have been carefully chosen and should only be altered if data is being lost. Such a scenario might well occur if your system had mixed speed DRAM chips installed so that greater delays may be required to preserve the integrity of the data held in the slower memory chips.

u AUTO CONFIGURATION

This item will automatically configure the chipset timing. You may select 'manual' to set up following gray items by your specific need.

The choice: Manual, Auto, 100MHz or 133MHZ.

u SDRAM RAS ACTIVE TIME

This item defines SDRAM ACT to PRE command period. The Choice: 6T, 7T, 5T, 4T.

u SDRAM RAS Precharge Time

This item defines SDRAM PRE to ACT command period. The Choice: 3T, 2T, 4T, Reserved.

u RAS TO CAS DELAY This item defines SDRAM ACT to Read/Write command period. The choice: 3T, 2T, 4T, Reserved.

u DRAM BACKGROUND COMMAND

This item is lead-off time control for DRAM background command. When select 'Delay 1T', background commands are issued 1 clock behind memory address (MA) been issued. When select 'Normal', background command and MA are issued at the same time.

The choice: Delay 1T or Normal.

Page 129 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 129 · click to enlarge
Page 129

u LD-OFF DRAM RD/WR CYCLES

The item is lead-off time control for DRAM Read/Write Cycles. When select 'Delay 1T', memory read/write command is issued 1 clock behind memory address (MA) been issued. When select 'Normal', read/write command amd MA are issued at the same time.

The choice: Delay 1T or Normal.

u WRITE RECOVERY TIME This item defines the Data-in to PRE command period.

The choice1T or 2T

u VCM REF TO ACT/REF DELAY This item defines VCM REF to REF/ACT command period. The choice: 10T, or 9T.

u VCM ACCT TO ACT/REF DELAY This item defines VCM ACT to ACT/REF command period. The choice: 10T, 9T, 8T or Reserved.

u EARLY CKE DELAY 1T CNTRL

When this item is enabled, CKE is driven out from flip-flop. It is used when system operates under low frequency and CKE delay adjustment method defined in the 'Early CKE Delay Adjustment' which can not meet setup time and hold time requirement.

The choice: Normal, Delay 1T.

u Early CKE Delay Adjust This item controls the timing for CKE. Various delay options are provided to ensure that CKE can meet SDRAM setup time and hold time specification when CKE is driven out.

The Choice: 1ns, 2ns, 3ns, 4ns, 5ns, 6ns, 7ns, 8ns.

u MEM COMMAND OUTPUT TIME

This item is to control the timing to drive memory command onto memory bus.

The choice: Normal, Delay 1T.

Page 130 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 130 · click to enlarge
Page 130

u SDRAM/VCM CAS LATENCY

When synchronous DRAM is installed, the number of clock cycles of CAS latency depends on the DRAM timing.

The Choice2, 3 or SPD

u SDRCLK CONTROL

This item controls the phase of SDRCLK that lags behind SDCLK. The choice: Enabled or Disabled.

u SDWCLK CONTROL CS#/CKE

This item controls the phase of SDWCLK used for chip set select signals pin that lags ahead SDCLK.

The choice: Enabled or Disabled.

u SDWCLK CONTROL MA/SRAS

This item controls the phase of SDWCLK used for MA/ SRAS signals that lags ahead SDCLK. The choice: +5.0ns~-2.5ns (Default 0.0ns)

u SDWCLK CONTROL DQM/MD

This item controls the phase of SDWCLK used for DQM/MD signals that lags ahead SDCLK.

The choice+5.0ns~-2.5ns (Default 0.0ns)

u EGMRCLK CONTROL

This item controls the phase of EGMRCLK that lags behind SDCLK. The choice: -1.0ns~+6.5ns (Default 0.0ns)

u EGMWCLK CONTROL

This item controls the phase of EGMWCLK that lags ahead SDCLK.

The choice+5.0ns~-2.5ns (Default 0.0ns)
Page 131 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 131 · click to enlarge
Page 131

u SYSTEM BIOS CACHEABLE

Selecting Enabled allows caching of the system BIOS ROM at F0000h-FFFFFh, resulting in better system performance. However, if any program writes to this memory area, a system error may result.

The choice: Enabled or Disabled.

u VIDEO RAM CACHEABLE

Select Enabled allows caching of the video RAM , resulting in better system performance. However, if any program writes to this memory area, a system error may result. The choice: Enabled or Disabled.

u MEMORY HOLE AT 15M-16M

You can reserve this area of system memory for ISA adapter ROM. When this area is reserved, it cannot be cached. The user information of peripherals that need to use this area of system memory usually discusses their memory requirements.

The choice: Enabled or Disabled.

u AGP APERTURE SIZE Select the size of Accelerated Graphics Port (AGP) aperture. The aperture is a portion of the PCI memory address range dedicated for graphics memory address space. Host cycles that hit the aperture range are forwarded to the AGP without any translation.

The Choice4M, 8M, 16M, 32M, 64M, 128M, 256M

u GRAPHIC WINDOW WR COMBIN

Use this item to enable or disable CPU support for WR Combin. The choice: Enabled or Disabled.

Page 132 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 132 · click to enlarge
Page 132

u CONCURRENT FUNCTION (MEM)

This item is CPU & PCI Masters Concurrently Access Memory Function. Select enabled allows CPU access memory cycles and PCI masters access memory cycles concurrently issued onto host bus and PCI bus, respectively, and then the memory access cycles will be rearranged by SiS630 to memory sequentially. The choice: Enabled or Disabled.

u CONCURRENT FUNCTION (PCI)

This item is CPU & PCI Masters Concurrently Access PCI Bus Function. Select enabled allows CPU access PCI bus cycle and PCI masters access memory cycles concurrently issued onto host bus and PCI bus, respectively.

The choice: Enabled or Disabled.

u CPU PIPELINE CONTROL

When enabled this item, only one pending cycle is allowed at one time.

When disabled, there might be more than two pending cycles at one time depends on the CPU behavior. The choice: Enabled or Disabled.

u PCI DELAY TRANSACTION

If the chipset has an embedded 32-bit write buffer to support delay transaction cycles, you can enable this item to provide compliance with PCI Ver.2.1 specifications. We recommend that you leave this item at the default value.

The choice: Enabled or Disabled.

u MEMORY PARITY CHECK

Enabled this item to test the boot-up memory. . The choice: Enabled or Disabled.

Page 133 of the Apollo Commercial Clothes Dryer (150 III) user manual — 7.4.5. Integrated Peripherals
Page 133 · click to enlarge
Page 133

7.4.5. Integrated Peripherals

If the INTEGRATED PERIPHERALS option is selected from the main menu, the screen below will appear. The following sample screen consists of the default values for PC 610.

CMOS Setup Utility – Copyright (C) 1984-200 Award Software

Item Help SIS 630 OnChip IDE Device (Press Enter)

SIS 630 OnChip PCI Device (Press Enter)

USB Keyboard Support (Disabled)

IDE HDD Block Mode (Enabled)

Onboard FDC Controller (Enabled)

Onboard Serial Port 1 (3F8/IRQ4)

Onboard Serial Port 2 (2F8/IRQ3)

UART Mode Select (Normal)

RxD, TxD Active (Hi, Lo)

IR Transmission Delay (Enabled)

UR2 Duplex Mode (Half)

Use IR Pins (IR-Rx2Tx2)

IR Transmission Delay (Enabled)

Onboard Parallel Port (378/IRQ7)

Parallel Port Mode (SPP)

EPP Mode Select (EPP1.7)

ECP Mode Use DMA (3)

Game Port Address (201)

Midi Port Address (330)

Midi Port IRQ (5)

Onboard Serial Port 3 (3E8)

Serial Port 3 Use IRQ (IRQ 10)

Onboard Serial Port 4 (2E8)

Serial Port 4 Use IRQ (IRQ 11)

Init Display First (PCI slot)

Fast Write Capability (Enabled)

AGP 4X Capability (Enabled)

AGP Auto Calibration (Enabled)

System Share Memory (8MB)

Show 4 more labels / short text on this page
Advanced BIOS Features · Menu Level · USB Controller (Enabled) · Extended Graphic Memory
Page 134 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 134 · click to enlarge
Page 134

SIS 630 ONCHIP IDE DEVICE

u INTERNAL PCI / IDE

This chipset contains an internal PCI IDE interface with support for two IDE channels. The choice: Primary, Secondary or Both.

u IDE Primary Master/Slave PIO The four IDE PIO (Programmed Input / Output) fields let you set a PIO mode (0-4) for each of the four IDE devices that the onboard IDE interface supports. Modes 0 through 4 provide successively increased performance. In Auto mode, the system automatically determines the best mode for each device. The choice: Auto, Mode 0, Mode 1, Mode 2, Mode 3 or Mode 4.

u PRIMARY MASTER/SLAVE ULTRADMA

UDMA (Ultra DMA) is a DMA data transfer protocol that utilizes ATA commands and the ATA bus to allow DMA commands to transfer data at a maximum burst rate of 33 MB/s. When you select Auto in the four IDE UDMA fields (for each of up to four IDE devices that the internal PCI IDE interface supports), the system automatically determines the optimal data transfer rate for each IDE device.

The choice: Auto or Disabled.

u IDE BURST MODE Selecting Enabled reduces latency between each drive read/write cycle, but may cause instability in IDE subsystems that cannot support such fast performance. If you are getting disk drive errors, try setting this value to Disabled. This field does not appear when the Internal PCI/IDE field, above, is Disabled.

The choice: Enabled or Disabled.

Page 135 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 135 · click to enlarge
Page 135

SIS 630 ONCHIP PCI DEVICE

u SIS-7018 AC97 AUDIO Select Enabled to support AC97 Audio. The choice: Enabled or Disabled.

u SIS-900 10/100M ETHERNET

This item provides a total communication solution including 10/100Mb Fast Ethernet for Office requirement and 1Mb HomePNA for Home Networking. The choice: Enabled or Disabled.

u ONBOARD FDC CONTROLLER Select Enabled if your system has a floppy disk controller (FDC) installed on the system board and you wish to use it. If you install and-in FDC or the system has no floppy drive, select Disabled in this field. The choice: Enabled or Disabled. u ONBOARD SERIAL PORT 1/PORT 2/PORT 3/PORT 4 Select an address and corresponding interrupt for the first and second serial ports. The choice: 3F8/IRQ4, 2F8/IRQ3, 3E8/IRQ10, 2E8/IRQ11, Disabled or Auto.

u UART MODE SELECT

This item allows you to select UART mode. The choice: Enabled or Disabled.

u UR2 DUPLEX MODE This item allows you to select the IR half/full duplex funcion.

The choice: Half or Full.

u ONBOARD PARALLEL PORT This item allows you to determine access onboard parallel port controller with which I/O address.

The choice: 3BC/IRQ7, 378/IRQ7, 278/IRQ5, Disabled.

Page 136 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 136 · click to enlarge
Page 136

u PARALLEL PORT MODE

Select an operating mode for the onboard parallel (printer) port. Select Normal, Compatible, or SPP unless you are certain your hardware and software both support one of the other available modes.

The choice: SPP, EPP, ECP, ECP+EPP.

u ECP MODE USE DMA

Select a DMA channel for the parallel port for use during ECP mode.

The choice: 3, 1.

u USB CONTROLLER Select Enabled if your system contains a Universal Serial Bus (USB) controller and you have USB peripherals.

The choice: Enabled or Disabled.

u USB KEYBOARD SUPPORT

Select Enabled if your system contains a Universal Serial Bus (USB) controller and you have a USB keyboard.

The choice: Enabled or Disabled.

u IDE HDD BLOCK MODE Block mode is also called block transfer, multiple commands, or multiple sector read/write. If your IDE hard drive supports block mode (most new drives do), select Enabled for automatic detection of the optimal number of block read/writes per sector the drive can support.

The choice: Enabled or Disabled.

u INIT DISPLAY FIRST

This item allows you to decide to active which bus first (PCI Slot or AGP first). The choice: PCI Slot or, AGP.

u SYSTEM SHARE MEMORY SIZE

This item defines the System Share Memory Size for video.

The choice2MB, 4MB, 8MB, 16MB, 32MB, 64MB
Page 137 of the Apollo Commercial Clothes Dryer (150 III) user manual — 7.4.6. Power Management Setup
Page 137 · click to enlarge
Page 137

7.4.6. Power Management Setup

If the POWER MANAGEMENT SETUP option is selected from the main menu, the screen below will appear. The following sample screen consists of the default values for PC 610.

CMOS Setup Utility – Copyright (C) 1984-200 Award Software

Item Help ACPI function (Enabled)

ACPI Suspend Type (S3 (STR))

Video OFF Option (Susp, Stby - Off)

Video Off Method (V/H, SYNC+B) ank)

Modem Use IRQ (3)

Hot Key Function As (Power Off)

HDD Off After (Disable)

Power Button Override (Instant Off)

Power Status Resume Control (Always Off)

Ø PM Wake Up Event (Press Enter)

: Move Enter : Select +/-/PU/PD: Value F10: Save

ESCExit F1: General Help F5: Previous Values F6: Fail-Safe Defaults
F7Optimized Defaults

Power Management Setup · Menu Level · Switch Function (Break/Wake)

Page 138 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 138 · click to enlarge
Page 138

u ACPI FUNCTION

This item allows you to enable/disable the Advanced Configuration and Power Management (ACPI).

The choice: Enabled or Disabled.

u ACPI SUSPEND TYPE

This item allows you to S1(Power ON Suspend)/S3(Suspend To RAM) the Advanced Configuration and Power Management (ACPI).

The choice: S1(POS) or S3(STR).

u VIDEO OFF OPTION

When enabled, this feature allows the VGA adapter to operate in a power saving mode. Always On Monitor will remain on during power saving modes. Suspend --> Off Monitor blanked when the systems enters the Suspend mode. Susp,Stby --> Off Monitor blanked when the system enters either Suspend or Standby modes. All Modes --> Off Monitor blanked when the system enters any power saving mode.

Page 139 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 139 · click to enlarge
Page 139

u VIDEO OFF METHOD

This determines the manner in which the monitor is blanked. V/H SYNC+Blank This selection will cause the system to turn off the vertical and horizontal synchronization ports and write blanks to the video buffer. Blank Screen This option only writes blanks to the video buffer. DPMS Select this option if your monitor supports the Display Power Management Signaling (DPMS) standard of the Video Electronics Standards to select video power management values.

u SWITCH FUNCTION

You can choose whether or not to permit your system to enter complete Suspend mode. Suspend mode offers greater power savings, with a correspondingly longer awakening period..

The choice: Break/Wake, Disabled. Hot Key Function As Select Enabled if your system has a hot key for soft power off.

The choice: Enabled or Disabled.

u HDD OFF AFTER

By default, this item is Disabled, meaning that no matter the mode the rest of the system, the hard drive will remain ready. Otherwise, you have a range of choices from 1 to 15 minutes or Suspend. This means that you can elect to have your hard disk drive be turned off after a selected number of minutes or when the rest of the system goes into a Suspend mode.

u POWER BUTTON OVER RIDE You could press the power button for more than 4 seconds forces the system to enter the Soft-Off state when the system has “hung.”

The choice: Soft-Off, Delay 4 Sec.

Page 140 of the Apollo Commercial Clothes Dryer (150 III) user manual — PM W AKE U P E VENTS
Page 140 · click to enlarge
Page 140

PM W AKE U P E VENTS

u IRQ [3-7,9-15], NMI

The following is a list of IRQ’s, Interrupt ReQuests, which can be exempted much as the COM ports and LPT ports above can. When an I/O device wants to gain the attention of the operating system, it signals this by causing an IRQ to occur. When the operating system is ready to respond to the request, it interrupts itself and performs the service.

  • As above, the choices are On and Off. When set On , activity will neither prevent the system from going into a power management mode nor awaken it.
  • IRQ [3-7, 9-15], NMI
  • IRQ 8 Break Suspend: You can Enable or Disable monitoring of IRQ8 (the Real Time Clock) so it does not awaken the system from Suspend mode.

u RING / PCIPME POWER UP CONTROL

When you select Enabled, a signal from ring / PCIPME returns the system to Full On state. The choice: Enabled or Disabled.

u KB POWER ON PASSWORD This item can be used to prompt the used for a password when the system power is resumed by keyboard action.

The choice: Enabled or Disabled.

u POWER UP BY ALARM

When you select Enabled, the following fields appear. They let you set the alarm that returns the system to Full On state. Date (of Month) Alarm lets you select a day from 1 to 31 . Time Alarm lets you select a time for the alarm in hours , minutes , and seconds .

The choice: Enabled or Disabled.

Page 141 of the Apollo Commercial Clothes Dryer (150 III) user manual — 7.4.7. PnP/PCI Configuration
Page 141 · click to enlarge
Page 141

7.4.7. PnP/PCI Configuration

If the PNP/PCI CONFIGURATION option is selected from the main menu, the screen below will appear. The following sample screen consists of the default values for PC 610.

CMOS Setup Utility – Copyright (C) 1984-200 Award Software

Item Help Reset Configuration Data (Disabled)

Resources Controlled By (Auto(ESCD))

x IRQ Resources Press Enter

Default is Disabled.

Select Enabled to rest

PCI/VGA Palette Snoop (Disabled)

ESCD) when you exit

Setup if you have

installed a new add-on

caused such a serious

conflict that the OS

: Move Enter : Select +/-/PU/PD: Value F10: Save

ESCExit F1: General Help F5: Previous Values F6: Fail-Safe Defaults F7: Optimized Defaults
Show 7 more labels / short text on this page
PnP PCI Configuration · Menu Level · Extended System · Configuration Data · and the system · reconfiguration has · cannot boot
Page 142 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 142 · click to enlarge
Page 142

u RESET CONFIGURATION DATA

Normally, you leave this field Disabled. Select Enabled to reset Extended System Configuration Data (ESCD) when you exit Setup if you have installed a new add-on and the system reconfiguration has caused such a serious conflict that the operating system can not boot.

The choice: Enabled or Disabled.

u RESOURCE CONTROLLED BY The Award Plug and Play BIOS has the capacity to automatically configure all of the boot and Plug and Play compatible devices.

However, this capability means absolutely nothing unless you are using a Plug and Play operating system such as Windows95. If you set this field to “manual” choose specific resources by going into each of the sub menu that follows this field (a sub menu is preceded by a “Ø”).

The choice: Auto(ESCD), Manual.

u IRQ RESOURCES

When resources are controlled manually, assign each system interrupt a type, depending on the type of device using the interrupt.

u IRQ3/4/5/7/9/10/11/12/14/15 ASSIGNED TO

This item allows you to determine the IRQ assigned to the ISA bus and is not available to any PCI slot. Legacy ISA for devices compliant with the original PC AT bus specification, PCI/ISA PnP for devices compliant with the Plug and Play standard whether designed for PCI or ISA bus architecture. The Choice: Legacy ISA and PCI/ISA PnP.

u PCI/VGA PALETTE SNOOP

Leave this field at Disabled. The choice: Enabled or Disabled.

Page 143 of the Apollo Commercial Clothes Dryer (150 III) user manual — VIO 3.3V
Page 143 · click to enlarge
Page 143

7.4.8. PC Health Status

The PC HEALTH STATUS auto detects the system’s temperature, voltage and fan speed.

CMOS Setup Utility – Copyright (C) 1984-200 Award Software

Item Help CPU Warning Temperature (Disabled)

Current System Temp.

VIO 3.3V

+ 5 V

+12 V

VBAT (V)

5VSB (V)

: Move Enter: Select +/-/PU/PD: Value F10: Save

ESCExit F1: General Help F5: Previous Values F6: Fail-Safe Defaults F7: Optimized Defaults
Show 7 more labels / short text on this page
PC Health Status · Menu Level · Current CPU1 Temperature · Current FAN1 Speed · Current FAN2 Speed · CPU VCore · Shutdown Temperature (Disabled)
Page 144 of the Apollo Commercial Clothes Dryer (150 III) user manual — 7.4.9. Frequency Voltage Control
Page 144 · click to enlarge
Page 144

7.4.9. Frequency Voltage Control

This setup page is for the CPU, SDRAM and PCI frequency setting.

CMOS Setup Utility – Copyright (C) 1984-200 Award Software

Item Help Auto Detect DIMM/PCI Clk (Enabled)

CPU Host/SDRAM/PCI Clock (Default)

: Move Enter : Select +/-/PU/PD: Value F10: Save

ESCExit F1: General Help F5: Previous Values F6: Fail-Safe Defaults F7: Optimized Defaults

Frequency Voltage Control · Spread Spectrum (Disabled) · Menu Level

Page 145 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 145 · click to enlarge
Page 145

u AUTO DETECT DIMM/PCI CLK

This item allows you to enable/disable auto detect DIMM/PCI Clock.

The choice: Enabled or Disabled.

u SPREAD SPECTRUM

This item allows you to enable/disable the spread spectrum modulate. The choice: Enabled or Disabled.

u CPU HOST/DRAM/PCI CLOCK

This item allows you to select CPU/PCI frequency. The choice: Auto Detect, 66/66/33MHz, 66/100/33MHz, 100/100/33MHz, 100/133/33MHz, 133/100/33MHz,

133/133/33MHz

Page 146 of the Apollo Commercial Clothes Dryer (150 III) user manual — 7.4.10. Load Fail-Safe Defaults
Page 146 · click to enlarge
Page 146

7.4.10. Load Fail-Safe Defaults

The default values of the LOAD FAIL-SAFE DEFAULTS indicates the most appropriate value of the system parameters that the system would be in safe configuration.

CMOS Setup Utility – Copyright (C) 1984-200 Award Software

Ø Standard CMOS Features

Ø Advanced BOIS Features

Ø Advanced Chipset Features

Save & Exit Setup

Ø Power Management Setup

Load Fail-Safe Defaults (Y/N) ? N

Ø PC Health Status

EscQuit F9 : Menu in BIOS : Select Item
F10Save & Exit Setup
Show 9 more labels / short text on this page
Ø Frequency/Voltage Control · Load Fail-Safe Defaults · Load Fail-Safe Defaults · Load Optimized Defaults · Set Password · Ø Integrated Peripherals · Exit Without Saving · Ø PnP/PCI Configuration · Load Fail-Safe Defaults
Page 147 of the Apollo Commercial Clothes Dryer (150 III) user manual — 7.4.11. Load Optimized Defaults
Page 147 · click to enlarge
Page 147

7.4.11. Load Optimized Defaults

The default values of the LOAD OPTIMIZED DEFAULTS indicates the most appropriate value of the system parameters that the system would be in best performance configuration.

CMOS Setup Utility – Copyright (C) 1984-200 Award Software

Ø Standard CMOS Features

Ø Advanced BOIS Features

Ø Advanced Chipset Features

Save & Exit Setup

Ø Power Management Setup

Load Optimized Defaults (Y/N) ? N

Ø PC Health Status

EscQuit F9 : Menu in BIOS : Select Item
F10Save & Exit Setup
Show 9 more labels / short text on this page
Ø Frequency/Voltage Control · Load Fail-Safe Defaults · Load Optimized Defaults · Load Optimized Defaults · Set Password · Ø Integrated Peripherals · Exit Without Saving · Ø PnP/PCI Configuration · Load Optimized Defaults
Page 148 of the Apollo Commercial Clothes Dryer (150 III) user manual — 7.4.12. User Password
Page 148 · click to enlarge
Page 148

7.4.12. User Password

The USER PASSWORD is used to set the password. To change the password, select this option from the main menu and press . If the CMOS does not work properly or the USER PASSWORD option is selected for the first time, then a default password is stored in the ROM. The following message will appear on the screen;

Press . If the CMOS is working properly or the USER PASSWORD option is selected to change the default password, then the current password (the ROM password or the use-defined password) stored in the ROM needs to be entered first. The following message will appear on the screen;

Enter the current password and press .

After pressing , then the new password (8 characters at most) can be entered now. The new password will be stored in the CMOS.

Please note that to enable this option, either Setup or System is to be selected from the ADVANCED BIOS FEATRUES first.

Enter Password · Confirm Password

Page 149 of the Apollo Commercial Clothes Dryer (150 III) user manual — 7.4.13. Save and Exit Setup
Page 149 · click to enlarge
Page 149

7.4.13. Save and Exit Setup

If the SAVE & EXIT SETUP option is selected, the values entered the setup utilities will be saved in the chipset’s CMOS memory. When the system is turned on every time, the CPU will check the CMOS to compare the CMOS data to see whether it matches the system. These data are very important for the system operation.

CMOS Setup Utility – Copyright (C) 1984-200 Award Software

Ø Standard CMOS Features

Ø Advanced BOIS Features

Ø Advanced Chipset Features

Save & Exit Setup

Ø Power Management Setup

Save & Exit Setup

Save to CMOS and Exit (Y/N) ? Y

Ø PC Health Status

EscQuit F9 : Menu in BIOS : Select Item
F10Save & Exit Setup

Save Data to CMOS

Show 7 more labels / short text on this page
Ø Frequency/Voltage Control · Load Fail-Safe Defaults · Load Optimized Defaults · Set Password · Ø Integrated Peripherals · Exit Without Saving · Ø PnP/PCI Configuration
Page 150 of the Apollo Commercial Clothes Dryer (150 III) user manual — 7.4.14. Exit Without Saving
Page 150 · click to enlarge
Page 150

7.4.14. Exit Without Saving

If the EXIT WITHOUT SAVING option is selected and is pressed, you will exit the Setup program without saving any new values. The CMOS will still keep the old values.

CMOS Setup Utility – Copyright (C) 1984-200 Award Software

Ø Standard CMOS Features

Ø Advanced BOIS Features

Ø Advanced Chipset Features

Save & Exit Setup

Ø Power Management Setup

Quit Without Saving Quit without Saving (Y/N) ? N

Ø PC Health Status

EscQuit F9 : Menu in BIOS : Select Item
F10Save & Exit Setup
Show 8 more labels / short text on this page
Ø Frequency/Voltage Control · Load Fail-Safe Defaults · Load Optimized Defaults · Set Password · Ø Integrated Peripherals · Exit Without Saving · Ø PnP/PCI Configuration · Abandon All Data
Page 151 of the Apollo Commercial Clothes Dryer (150 III) user manual — 8. S OFTWARE & D RIVERS INSTALLATION
Page 151 · click to enlarge
Page 151

8. S OFTWARE & D RIVERS INSTALLATION

The chapter introduces the PC 610 onboard VGA, Ethernet, Audio and the respective drivers and installation.

Page 152 of the Apollo Commercial Clothes Dryer (150 III) user manual — 8.1. Ethernet Drivers
Page 152 · click to enlarge
Page 152

8.1. Ethernet Drivers

The PC 610 provides a 10/100 Base T fast Ethernet. The PC 610 Ethernet drive diskette or CD diskette contains the following drivers;

SiS630ST Ethernet drivers for ² Windows 95/95OSR2 ² Windows 98/98SE ² Windows 2000 ² Windows ME

² Windows NT 4.0 ² Windows XP For the Ethernet drivers, please download the updated drivers from the following website http://www.sis.com.tw

Page 153 of the Apollo Commercial Clothes Dryer (150 III) user manual — 8.2. PC 610 AGP XGA
Page 153 · click to enlarge
Page 153

8.2. PC 610 AGP XGA

By integrating an advanced hardware 2D/3D GUI engine and 64-bit graphic display interface, the PC 610 can deliver AGP 4X performance and memory bandwidth of up to 1GB. It adopts Share System Memory architecture which can flexibly utilize the frame buffer size up to 64MB.

In addition to providing standard interface for analog monitor, the PC 610 also provides an interface for digital flat panels.

The PC 610 XGA driver diskettes contain the following drivers; SiS630ST VGA drivers for ² Windows 9x

² Windows 2000/XP For the VGA drivers, please download the updated drivers from the following website http://www.sis.com.tw

Page 154 of the Apollo Commercial Clothes Dryer (150 III) user manual — 8.3. Audio Setup
Page 154 · click to enlarge
Page 154

8.3. Audio Setup

The PC 610 audio driver diskette contains the following drivers;

SiS630ST audio drivers for ² DOS ² Windows NT 4.0 ² Windows 2000 ² Windows 95/98 ² Windows 98SE

² Windows ME ² Windows XP For the audio drivers, please download the updated drivers from the following website

http://www.sis.com.tw

Page 155 of the Apollo Commercial Clothes Dryer (150 III) user manual — 8.4. Touchscreen Drivers
Page 155 · click to enlarge
Page 155

8.4. Touchscreen Drivers

The panel PC audio driver diskette contains the following drivers;

² 3M resistive touch drivers ² 3M capacitive touch drivers ² Elo resistive/SAW touch driver ² E-turbo touch drivers

Page 156 of the Apollo Commercial Clothes Dryer (150 III) user manual — 8.5. Driver Installation
Page 156 · click to enlarge
Page 156

8.5. Driver Installation

To install the Ethernet, VGA, Audio and Touchscreen drivers, find the drivers from the correct directory and execute the execution files. All the related drivers for the motherboard are stored in the floppy diskettes or the panel PC tool CD under the following route;

PanelPC & Motherboard/Drivers & Utilities/PC 6x0 & Panel PC (Socket 370, Celeron_P3)

The drivers for touchscreen are stored under the following route;

PanelPC & Motherboard/Drivers & Utilities/xxx Touch Find the brand and touch type installed with the panel PC and find related drivers in respective directories.

Please refer to the readme.txt file under each directory for more drivers’ information. Recent releases of operating systems always include setup programs that load automatically and guide you through the installation.

Page 157 of the Apollo Commercial Clothes Dryer (150 III) user manual — A-1. APOLLO 120 LCD
Page 157 · click to enlarge
Page 157

Appendix

A: LCD Specification

A-1. APOLLO 120 LCD

The standard display used for the APOLLO 120 is a TORISAN 12.1” TFT active matrix color liquid display (LCD) module; its model no. is MXS121022010 or its equivalent. It composes of LCD panel, driver ICs, control circuit and backlight. By applying 6 bit digital data, 800x600, 260K-color images are displayed on the 12.1” diagonal screen. Input power voltage is single 3.3V for LCD driving. A-1-2. SPECIFICATION

Inverter backlight is not included in this LCD module. General specifications are summarized in the following:

ITEM SPECIFICATION Display Area (mm) 246.0 (H) x 184.5 (V) (12.106 inch diagonal) Number of Pixel 800 x R.G.B (W) x 600 (H) Sub Pixel Pitch (mm) 0.1025 (W) x 0.3075 (H) Pixel Pitch (mm) 0.3075 (W) x 0.3075 (H) Number of Color 262144 colors Active Viewing Angle 246.0 (W) x 184.5 (H) Bezel opening area 250.0 (W) x 188.5 (H) Brightness (cd/m2) 150 (cd/m2 ) Module Size (mm) 275.0(W)*199(H)*6.9max (T) Module Weight (g) 440 g (TYP.) Backlight Unit CCFL, 1-tube

Page 158 of the Apollo Commercial Clothes Dryer (150 III) user manual — A-2-1-2. A BSOLUTE M AXIMUM R ATINGS
Page 158 · click to enlarge
Page 158

A-2. T HE LCD S FOR APOLLO 150

The standard display used for the APOLLO 150 is either LG 15.1” TFT LCD, LM151X2 or its equivalent or a Chi Mei 15” TFT LCD, M150X3-L01 or its equivalent.

A-2-1: 15.1” LG LM151X2 The LM151X2 is a TTL interface 15.1” TFT active matrix color liquid display. It comprises amorphous silicon TFT attached to each signal electrode, a driving circuit and a backlight. This LCD has a built-in backlight with inverter. The 38 cm (15.1”) diagonal display area contains 1024 x 768 pixels and can display more than 262,144 colors simultaneously. A-2-1-1 SPECIFICATION General specifications are summarized in the following:

Apollo Commercial Clothes Dryer (150 III) — A-2. T HE LCD S FOR APOLLO 150 diagram (page 158)
Fig. 71

ITEM SPECIFICATION Display Mode Normally white Number of Color 262144 colors Viewing Angle * Horizontal: 60o (typ. Left side, right side) * Vertical: 45o (typ. Up side, Down side) Cross talk Horizontal: 2.5% Vertical: 2.5% Response time 50ms(typ.) Brightness (cd/m2) 200 cd/m2 Life time 40,000 hrs Contrast Ratio 200:1

A-2-1-2. A BSOLUTE M AXIMUM R ATINGS

Apollo Commercial Clothes Dryer (150 III) — A-2-1-2. A BSOLUTE M AXIMUM R ATINGS diagram (page 158)
Fig. 72

ITEMS SYMBOL MIN. MAX. UNIT Power Supply Voltage VDD 0 +3.6 VDC Lamp Current IBL - 9.0 mArms Operating Temperature Top 0 50 oC Storage Temperature Tst -20 60 oC

Page 159 of the Apollo Commercial Clothes Dryer (150 III) user manual — A-2-2-3. A BSOLUTE M AXIMUM R ATINGS
Page 159 · click to enlarge
Page 159
A-2-115” Chi Mei M150X3-L01

The LM150X3_L01 is a 15.0” TFT Liquid Crystal Display module with 4 CCFL backlight units and 20 pins LVDD interface. This moulde supports 1024*768 XGA mode and can display 16.2M. The optimum viewing angle is at 6 o’clock direction. A-2-2-1. SPECIFICATION Inverter backlight is not included in this LCD module. General specifications are summarized in the following:

Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 159)
Fig. 73 · 5.6. HDD Module Assembly

ITEM SPECIFICATION Display Area (mm) 304.1 (H) x 228.15 (V) (15.0” diagonal) Bezel Opening Area (mm) 308.2 (H) x 232.1 (V) Driver Element a-Si TFT active matrix Pixel Number(pixel) 1024 x R.G.B (W) x 768 (H) Pixel Pitch (mm) 0.297 (W) x 0.297 (H) Pixel Arrangement RGB vertical stripe Display Color 16,194,277 colors Passive Mode Normally White Viewing Angle * Horizontal: θx+ 60 o, θx- 60 o * Vertical: θY+ 40 o, θY- 60 o Brightness (cd/m2) 250 (cd/m2 ) Module Weight (g) 1,350 g (max.) Backlight Unit CCFL, 4-tube

A-2-2-2. M ECHANICAL S PECIFICATION

Apollo Commercial Clothes Dryer (150 III) — A-2-2-2. M ECHANICAL S PECIFICATION diagram (page 159)
Fig. 74

Item Min. Typ. Max. Unit Horizontal (H) - 331.6 - mm Vertical (V) - 254.76 - mm Module Size

Depth (D) - 13.0 - mm Weight (1,350) G

A-2-2-3. A BSOLUTE M AXIMUM R ATINGS

Min. Max.

Power Supply Voltage VCC VSS0.3 4.0 V

Value Item Symbol · Unit

Page 160 of the Apollo Commercial Clothes Dryer (150 III) user manual — B: DiskOnChip Installation
Page 160 · click to enlarge
Page 160

B: DiskOnChip Installation

The APOLLO 120/150 III is equipped with an internal flash disk which can emulate a floppy disk drive by adapting DiskOnChip memory chips from 2MB to 144MB capacity, and the flash disk is fully compatible with floppy disk format of MS-DOS system. To install a DiskOnChip memory to the provided socket, follow the instructions below; 1. Make sure the computer is turned off 2. Insert the DiskOnChip memory device into the onboard socket. Make sure that pin 1 of the DiskOnChip is aligned with the pin 1 of the socket. 3. Power up the computer 4. During the power up, the DiskOnChip drivers will be automatically loaded into the system memory. 5. At this time, the DiskOnChip can be accessed as any disk drive. 6. If it is the only disk in the system, it will appear as the first drive, drive C:. 7. If there are more drives already attached to the system, then by default, the DiskOnChip will appear as the last drive unless specially programmed. 8. If the DiskOnChip is to be bootable, then follow the steps below

a. Use DOS command to copy the operating files into

the DiskOnChip b. The DiskOnChip is to be configured as the first

drive, drive C: in the system. Use the DUPDATE utility.

DUPDATE D /SDOC104.EXB /FIRST (set as c:) DUPDATE C /S: DOC104.EXB (set as d:)

For more information and for the latest software utility and utilities manual on the DiskOnChip, visit M-System website at www.m-sys.com.

Page 161 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 161 · click to enlarge
Page 161

C: System I/O Ports Address range (Hex) Device 000-01F DMA controller 020-021 Interrupt controller 1, master 022-023 Chipset address 040-05F 8254 timer 060-06F 8024 keyboard controller 070-07F Real time clock, non-maskable interrupt mask (NMI) 080-09F DMA page register 0A0-0BF Interrupt controller 2 0C0-0DF DMA controller 0F0 Clear math co-processor 0F1 Reset math co-processor 0F8-0FF Math co-processor 1F0-1F8 Fixed disk 200-207 Game Port (not used) 443 Watchdog timer 143 Watchdog timer 208 DIO port 2E8 Serial port #4 2F8-2FF Serial port #2 300-31F Prototype card (not used) 330-331 MPU-401 Compatible 360-36F Reserved 378-37F Parallel printer port 1 (LPT1) 380-38F SDLC, bisynchronous 2 (not used) 3A0-3AF Bisynchronous 1 (not used) 3B0-3BF Monochrome display and printer adapter (LPT1) (not used) 3C0-3CF Reserved 3D0-3DF Color/graphics monitor adapter 3E8 Serial port #3 3F0-3F7 Diskette controller 3F8-3FF Serial port #1

Page 162 of the Apollo Commercial Clothes Dryer (150 III) user manual — C: Wake-On-LAN
Page 162 · click to enlarge
Page 162

C: Wake-On-LAN

The Wake-On-LAN is a remote management tool with the advantage to reduce system management workload. It provides the capability to remotely power on the client computers supporting Wake-On-LAN by simply sending a “wake up packet”. After powering up the client systems, the user is able to monitor the remote systems’ status and to upload or download files to or from the clients. With this feature, MIS persons can flexibly perform client maintenance during off-hours; the Total Cost of Ownership (TCO) will be thus lowered. To use Wake On LAN function, the client system must have a network card with chipset that supports the Wake-On-LAN and an ATX power supply meeting 2.01 with at least 720mA standby current is also required to support the Ethernet card for this function. The APOLLO is a panel PC system with these two features. To use the APOLLO Wake-On-LAN function, please refer to the following; 1. Download the “Wake up packet”, PCnet Family Software Magic Packet Utility. This utility is downloadable from AMD website at http://www.amd.com/us-en/Networking/ProductInformatio n/0,,50_2330,00.html

Or refer to the Magic Packet ™ Technology at AMD website for how to write your own wake-up program.

http://www.amd.com/us-en/Networking/TechnicalResource s/0,,50_2334_2481,00.html 2. BIOS Setting Enter the \POWER MANAGEMENT SETUP\PM WAKE UP EVENTS to enable the MACPME POWER UP CONTROL

Page 163 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 163 · click to enlarge
Page 163
3. Wake up Packet To use the AMD’s Magic Packet, program installation is not needed. Just open the MAGPAC . EXE , then the following screen will pop up.
Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 163)
Fig. 75 · 5.6. HDD Module Assembly

The remote computer can be waken up by selecting the MAGIC PACKETS¢ @ POWER ON ONE HOST as shown below.

Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 163)
Fig. 76 · 5.6. HDD Module Assembly

Do not change the IP BROADCAST ADDRESS. The DESTINATION ETHERNET ADDRESS is to be filled in with the Ethernet card’s MAC address.

Page 164 of the Apollo Commercial Clothes Dryer (150 III) user manual — 5.6. HDD Module Assembly
Page 164 · click to enlarge
Page 164

To obtain the Ethernet card MAC, under Windows 9x, just enter START\RUN to open the winipcfg.exe, then the following screen will pop up. If the OS is Windows NT 4.0 or 2000 or XP, then you need to enter DOS mode to run ipconfig.exe to obtain the MAC.

Apollo Commercial Clothes Dryer (150 III) — 5.6. HDD Module Assembly diagram (page 164)
Fig. 77 · 5.6. HDD Module Assembly

The adapter address is the LAN card’s MAC address. 4. After obtaining all the above information, the remote computer can be powered on now.

Now you can use Desktop On Call or other remote software to control the remote computer.

Page 165 of the Apollo Commercial Clothes Dryer (150 III) user manual — D: First MB Memory Map
Page 165 · click to enlarge
Page 165

D: First MB Memory Map

Address range (Hex) Device F000h-FFFFh System ROM CC00h-EFFFh Unused C000h-CBFFh Expansion ROM B800h-BFFFh CGA/EGA/VGA text B000h-B7FFh Unused A000h-AFFFh EGA/VGA graphics 0000h-9FFFh Base memory D000-D7FFH DiskOnChip(Default)

Page 166 of the Apollo Commercial Clothes Dryer (150 III) user manual — E-1-1: E LECTRONIC S PECIFICATIONS
Page 166 · click to enlarge
Page 166

E: Power Supply

The APOLLO 120/150 III can either accommodate an AC power supply or a DC power supply.

E-1: AC POWER SUPPLY The AC power supply used in the APOLLO 120/150 III system is a 150 watts 1U ATX power supply. It is a dual output switching power supply specially designed for the APOLLO III system.

E-1-1: E LECTRONIC S PECIFICATIONS

INPUT Input range 100-127/200-240VAC, switch selectable Frequency 47~64Hz Input current 5A@ 115VAC, 2.5A@230VAC Inrush current 35@115VAC, 70A230VAC cold start at 25oC

OUTPUT Maximum power 150W Hold-up time 14ms at full load @115VAC Short circuit protection All output Overvoltage protection +3.3V > 130% +5V > 160%, +12V > 140%

E-1-2: ENVIRONMENT Operation 0oC to 50oC Shipping & storage -20oC to 60oC MTBF 100,000 hours at 75% of maximum continuous output loading at 25oC ambient conditions

Page 167 of the Apollo Commercial Clothes Dryer (150 III) user manual — E-1-3: I NTERNATIONAL S TANDARD
Page 167 · click to enlarge
Page 167

E-1-3: I NTERNATIONAL S TANDARD

Designed to meet the following standards UR TUV FCC B CE E-1-4: MECHANICAL SPECIFICATION

Apollo Commercial Clothes Dryer (150 III) — E-1-3: I NTERNATIONAL S TANDARD diagram (page 167)
Fig. 78

min. max. min. max peak min. max peak min max min max min max

0.5A 7A 1A 12A 14A 0.5A 5A 8A 0A 0.2A 0A 1A 0A 2A

² Dimension (unitmm)

180 x 100 x 40.5 (L x W x H)

² Safety standards

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Apollo Commercial Clothes Dryer (150 III)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Apollo Commercial Clothes Dryer (150 III)

Be the first to ask — other owners or our team will answer.

Original document

Apollo Commercial Clothes Dryer (150 III) manual PDF

167 pages·2.2 MB·Personal Computer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…