PLEASE READ THE FOLLOWING:
KEEP THESE INSTRUCTIONS
HEED ALL WARNINGS
FOLLOW ALL INSTRUCTIONS
the apparatus shall not be exposed to dripping or splashing liquid and no object filled withi liquid, such as vases, shall be placed on the appara tus.
CLEAN ONLY WITH A DRY CLOTH.
DO NOT BLOCK ANY OF THE VENTILATION OPENINGS. INSTALL IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUC TIONS.
DO NOT INSTALL NEAR ANY HEAT SOURC ES SUCH AS RADIATORS, HEAT REGISTERS, STOVES, OR OTHER APPARATUS (INCLUD ING AMPLIFIERS) THAT PRODUCE HEAT.
ONLY USE ATTACHMENTS/ACCESSORIES SPECIFIED BY THE MANUFACTURER.
UNPLUG THIS APPARATUS DURING LIGHT NING STORMS OR WHEN UNUSED FOR LONG PERIODS OF TIME.
Do not defeat the safety purpose of the polar ized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or third prong are provided for your safety. If the provided plug does not fit your outlet, consult an electrician for replacement of the obsolete outlet.
The cores in the mains lead are coloured in accordance with the following code:
GREEN and YELLOW - Earth BLUE - Neutral BROWN - Live
As colours of the cores in the mains lead of this appliance may not cor respond with the coloured markings identifying the terminals in your plug, proceed as follows:
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
Use only with the cart stand, tripod bracket, or table specified by the manufacture, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
Refer all servicing to to qualified service person nel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
POWER ON/OFF SWITCH: The Power switch used in this piece of equipment DOES NOT break the connection from the mains.
MAINS DISCONNECT: The plug shall remain readily operable. For rack-mount or installation where plug is not accessible, an all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated into the electrical installation of the rack or building.
FOR UNITS EQUIPPED WITH EXTERNALLY ACCESSIBLE FUSE RECEPTACLE: Replace fuse with same type and rating only.
MULTIPLE-INPUT VOLTAGE: This equipment may require the use of a different line cord, attachment plug, or both, depending on the avail able power source at installation. Connect this equipment only to the power source indicated on the equipment rear panel. To reduce the risk of fire or electric shock, refer servicing to quali fied service personnel or equivalent.
Safety Instructions

DECLARATION OF CONFORMITY
declares that the product:
Product name: PCM96 Note: Product name may be suffixed by the EU.
conforms to the following Product Specifications:
Supplementary Information:
The product herewith complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC as amended by Directive 93/68/EEC. Director of Lexicon Engineering 8760 S. Sandy Parkway Sandy, Utah 84070, USA Date: October 15, 2007
Harman Music Group 8760 South Sandy Parkway Sandy, Utah 84070, USA Ph: (801) 566-8800 Fax: (801) 566-7005
U.K. MAINS PLUG WARNING
COMPATIBILITY
A molded mains plug that has been cut off from the cord us unsafe. Discard the mains plug at a suitable disposal facility. NEVER UNDER ANY CIRCUMSTANCES SHOULD YOU INSERT A DAMAGED OR CUT MAINS PLUG INTO A 13 AMP POWER SOCKET. Do not use the mains plug without the fuse cover in place. Replaceent fuse covers can be obtained from your local retailer. Replacement fuses are 13 amps and MUST be ASTA approved to BS1362.
This unit conforms to the Product Specifications noted on the Declaration of Conformity. Operation is subject to the following two conditions:
If you want to dispose this product, do not mix it with general household waste. There is a separate collection system for used electronic products in accordance with legislation that requires proper treatment, recovery and recycling.
Private household in the 25 member states of the EU, in Switzerland and Norway may return their used electronic products free of charge to designated collection facilities or to a retailer (if you purchase a similar new one).
For Countries not mentioned above, please contact your local authorities for a correct method of disposal.
By doing so you will ensure that your disposed product undergoes the necessary treatment, recovery and recycling and thus prevent potential negative effects on the environment and human health.

This warranty is valid only for the original purchaser and only in the United States. If outside the United States please contact the local Lexicon® distribu tor.
3. Lexicon Professional’s liability under this warranty is limited to repairing or, at our discretion, replacing defective materials that show evidence of defect, provided the product is returned to Lexicon Professional WITH RETURN AUTHORIZATION from the factory, where all parts and labor will be covered up to a period of 1 year. A Return Authorization number must be obtained from Lexicon Professional by telephone. The company shall not be liable for any consequential damage as a result of the product’s use in any circuit or assembly.





Introduction Congratulations and thank you for purchasing the PCM96 Reverb/Multi Effects Processor! The PCM96 offers legendary reverbs you’ve come to expect from Lexicon®, plus new mono reverbs, new room algorithms with selectable, reversible reflection patterns, and more. And you can add it all to your recording software via FireWireTM connectors supporting four 96kHz sample rate audio streams in each direction.
The PCM96’s intuitive front panel makes operation simple. Just select a preset and load it to hear the reverb or effect you want. Adjust a preset’s “soft row” parameters with the three Parameter knobs. Or dial up and adjust any parameter with the large Navigation knob. Save or load presets with a Compact Flash memory card. Use the Compare button to A-B the original preset with changes you’ve made to it.
With its unmatched reverbs and effects, intuitive interface, and seamless inte gration with your recording software, the PCM96 will prove to be a valuable addition in your studio.
Included Items



9 8 7 6 5 4 3

4. A, B, and C Knobs These knobs adjust parameters shown in the Display. Turn Knob A to adjust the parameter in the top row, Knob B to adjust the parameter in the second row, and Knob C to adjust the parameter in the third row. Press Knob A to access additional pages of parameters when in the Soft Row. Press Knob C to view the current preset’s Algorithm, Bank number, Program number, and MIDI channel. These knob also have additional context-sensitive functions when pressed.

13. COMPARE This button is used to compare an edited preset against its unedited self. When a preset is loaded, this button’s LED is off. As soon as the preset is edited in any fashion, the LED lights. If the button is pressed, the edited state is temporarily stored and the preset is reloaded from the file system. During this period of time, editing is disallowed and the button LED blinks rapidly. When the Compare button is pressed a second time, the edited state is restored, editing is allowed again, and the LED is illuminated.


MIDI THRU Passes any MIDI data received without change.
MIDI OUT Transmits MIDI data to other equipment.



Powering Up the PCM96
Plug in the power cord. 1. Press the Power button. 2. The Lexicon 3. ® logo appears, and remains until the boot process is com plete. Next, the Preset screen appears, showing the currently loaded pre set. The Preset Screen The Preset screen is the starting point for many of the instructions in this manual, so it’s a good idea to know how to get to the Preset screen. In most cases, pressing the Back button one or more times will take you back to the Preset screen. If you press the Back button while viewing the Preset screen, you’ll arrive at the Machine or System Category Selection screen. In this case, just turn the Select knob to select a category (the current category is marked with an asterisk), and press the Select knob to load it. You will then be taken to the Preset screen.
The Preset screen shows the current preset and configuration. Note that the Preset screen has two “views”: System view (for System Presets) and Machine view (for Machine Presets). For more information about System and Machine Presets, see page 9.

Clock Sync icon

System View · Machine View

Selecting Your Audio Source and Clock Source
Press the Machine button until the words “System View” appear in the 1. Display.

Press the Select knob. The System Menu appears. 2.

System Menu Version 1.0 +Audio Setup +System Control +MIDI Control
With Audio Setup highlighted, press the Select knob. The Audio Setup 3. menu appears.

Turn Knob A to select your audio source (Analog or AES). 4. Turn Knob B to select your wordclock source (Internal, AES, or BNC). 5. Press the Back button twice to save your changes and return to the 6. Preset screen.
From the Preset screen, turn the Select knob to scroll through the avail 1. able presets in the current category. (Presets are arranged in categories within the PCM96; see Changing Categories below for more informa tion.) The preset name blinks after you turn the Select knob, indicating that you are in preset selection mode. Press the Select knob to load the preset you’ve selected. The display 2. briefly reads Loading Preset, and the preset name appears. It is no longer blinking.
Changing Categories Presets are grouped into categories in the PCM96. Each category has its own set of presets. When you turn the Select knob while viewing a preset, you only see presets available in the current category.
System Presets and Machine Presets each have their own set of categories. System Preset categories are based on DSP configurations (see page 14), and Machine Preset categories are based on algorithms (see page 33).
Loading a Preset

System Presets and Machine Presets also have User and Card categories, where you can access user-edited presets. Presets in the User category are stored on the PCM96, and presets in the Card category are stored on a Compact Flash card.
To select a different category
From the Preset screen, press the Back button. The Category Selection 1. screen appears. Note that there are different Category Selection screens for System Presets and Machine Presets: Category Selection Screen - System Presets

Default Configurations * Combined Mono Reverbs Combined Mono Effects

Turn the Select knob to scroll through the available categories. (An aster 2. isk appears next to the currently selected category.) Press the Select knob to load the highlighted category. A flashing preset 3. name appears (if it is not the currently selected preset). Select a preset with the Select knob, and press the Select knob to load it. 4.
System Presets and Machine Presets The PCM96 features a single powerful processor, which can be used as up to four virtual machines. For example, you could send the left input signal through a mono reverb in one virtual machine and send the right input sig nal through a mono delay in another virtual machine. You could then send both signals through a chorus effect on a third virtual machine. You could then save this configuration as a System Preset. It’s a preset that includes a system of virtual machines. (Note that System Presets are not available in the PCM96 plug-in. See page 15 for more information about the plug-in.)
System Presets can be extremely complex and are generally tailored especially for the mix you’re working on. Lexicon® has provided a number of these presets, just to give you an idea about what you might do. Who knows? You might like them just the way they are. Feel free to make modified ver sions of the factory presets, or create your own from scratch. The possibili ties are nearly endless, so have fun.
When a preset only includes a single virtual machine, it’s called a Machine Preset.


The configuration icon The Configuration icon appears at the upper right corner of the Display. It tells you if a System Preset or a Machine Preset is loaded.
When a System Preset is loaded, a border appears around the Configuration icon and the words System View appear in the Display, below the preset’s name.

(System Preset)
When a Machine Preset is loaded, the selected machine is highlighted in the Configuration icon, and three of the loaded preset’s parameters appear at the bottom of the Display.


(Machine Preset)
Press the Machine button repeatedly to cycle through the virtual machines in a System Preset, and eventually back to the System Preset.
Editing a Preset To edit a System Preset, you must edit the virtual machines within it. Press the Machine button to cycle through the virtual machines within a System Preset.
Each virtual machine contains a set of parameters that you can edit and adjust. When a virtual machine is selected, three of its parameters appear at the bottom of the Display. Adjust the first parameter with Knob A, the sec ond parameter with Knob B, and the third parameter with Knob C. To see the next set of parameters you can adjust, press Knob A.

Each virtual machine has 8 parameters you can adjust this way. All presets have more than 8 parameters, but only 8 can be edited via the A, B, and C knobs in this fashion. You can choose which parameters are in the list by using the Soft Row Setup menu located in the Machine menu (see page 26 for more information).

Storing a Preset Once you’ve edited a preset, you can store it on the PCM96 (in the User cat egory) or on a Compact Flash card (in the Card category).
From the Preset screen, press the Store button. The Save As screen 1. appears.
Select Knob -> Change Position
ʻAʼ Knob -> Change Letter
Turn the Select knob to select a letter to change. 2. Turn Knob A to change the selected letter. 3. Press Knob A to toggle between uppercase, lowercase, special characters and numbers. Press Knob B to clear the selected character space. Repeat steps 2 and 3 until you’ve changed all the letters you want to 4. change. Press the Select knob to continue. If a Flash card is inserted, the 5. Location menu appears. (If no Flash card is inserted, skip to step 8.)
Turn the Select knob to select a location. “User” is the PCM96 built-in 6. memory; “Flash” is the inserted Compact Flash card (if one is present). Press the Select knob to continue. The numbered list appears. 7.
0:- Empty - 1:- Empty - 2:- Empty - 3:- Empty - 4:- Empty -
Turn the Select knob to select a slot in the numbered list. The preset’s 8. name automatically appears in the selected slot. Press the Select knob to save the preset to the selected slot. “Storing 9. Preset” appears briefly in the Display and you are returned to the Preset screen.
User Card

Initializing/formatting a Compact Flash Card To initialize or format a Compact Flash card:
Press the Back button until the Preset screen appears. 1. Press the Machine button until System View is displayed. 2. Press the Select knob to enter the System Menu. 3. Turn the Select knob until Card Config is highlighted. 4. Press the Select knob to access the Compact Flash Menu. 5. Press Knob B to Format the card OR press Knob C to initialize the card. 6.
Creating a new System Preset One way to create a new System Preset is to edit an existing System Preset and save it to the User or Card category. Another way is to start from scratch, as described below.
With any System Preset loaded, press the Select knob. The System menu 1. appears. Highlight Machine Config with the Select knob, and press the Select 2. knob. The available DSP configurations appear. Turn the Select knob to highlight a configuration and press the Select 3. knob to choose it. You return to the Preset Screen. The preset’s name indicates the configuration you just selected (for example, if you selected the Cascade Stereo configuration, the preset’s name is Cascade Stereo Config). Press the Machine button to select a Machine Preset within your System 4. Preset. Press the Back button to access the Preset Category menu. 5. Turn the Select knob to highlight a category and press the Select knob to 6. choose it. A flashing Machine Preset name appears. Turn the Select knob to choose a Machine Preset and press the Select 7. knob to load it. Press the Machine Button to choose the next Machine Preset (if there is 8. one) and repeat steps 5 through 7. Repeat step 8 for each virtual machine in your System Preset. 9. Press the Machine Button until your System Preset is selected. 10. Press the Store button and follow the Storing a Preset procedure 11. described on page 12.

DSP Configurations The PCM96 processor can be divided in up to four virtual machines, each of which can run its own algorithm. This lets you route signals from each input through a variety of algorithm combinations.
The PCM96 can use up to two physical inputs and two physical outputs at a time; configurations for the physical inputs and outputs are described below. Note that the software plug-in lets the PCM96 use up to four inputs and outputs via FireWireTM; those configurations are only accessible in the soft ware plug-in, and are described on page 18.
Single Mono In Stereo Out
A mono signal is split into a stereo signal.
The left and right inputs are sent through a single virtual machine.
The left signal travels through one virtual machine, and the right signal travels through a separate second virtual machine.
The left and right signals are processed together in one virtual machine, and the resulting signal is sent to a second virtual machine, where they are again processed together.
The left signal is sent through two virtual machines in sequence, while the right signal is sent through two additional virtual machines in sequence. The left and right signals are processed independent from each other.
Cascade Mono to Stereo
The left and right signals are processed independently in two separate virtual machines, and their resulting signals are pro- cessed together in a third virtual machine. The final result is output as stereo.
Combined STereo Mono In
This configuration features two stereo machines. Each receives one of the input channels. The two stereo outputs are combined and output as a single stereo pair.

The PCM96 Plug-IN The plug-in lets you add PCM96 reverbs and effects to projects on your Digital Audio Workstation (DAW).
Installing the Plug-In software To install the PCM96 plug-in:
Double-click the PCM96_Installer x.x.x.x.dmg file (where “x.x.x.x.” is 1. the version number) on the included DVD. The dmg file opens. Double-click the PCM96_Installer x.x.x.x.dmg to begin the installer. 2. Follow the on-screen instructions to complete installation. 3. If you require RTAS support, open the PCM96_RTAS_Installer package 4. after installing the LexiconPro-x.x.x.x package and rebooting.
To uninstall the plug-in software, select Uninstall from the DVD and follow the on-screen instructions.
Minimum System Requirements Mac® OS 10.4.9 or higher
Using the Plug-In Once you’ve created a project in your DAW and added an audio track, use your DAW to add an insert. Navigate to the PCM96 menu and select any PCM96 algorithm from the list. The PCM96 plug-in window appears.
When you first open the PCM96 plug-in, its default connection type is FireWireTM. To change the connection type (and other settings) while using the plug-in, open the PCM96 Control Panel, described on page 17.
To exit Application Lockout, close your DAW or disconnect the cable con necting the PCM96 to your computer.

When the plug-in window first opens, it shows only a single control area. Here you can click the up and down Program arrows to scroll through the presets available for the selected algorithm, or click the Load button to select from a list. Click the Load button at the bottom of the list to load the select ed preset, or click the Cancel button to cancel the selection.
Click the single down arrow in the lower right corner to open the second plug-in control area.
Plug-in Window Controls


In the second control area, you can adjust the soft row parameters by click ing on and moving the sliders. Note that the soft row parameters vary from preset to preset. Click the down arrow in the lower right corner to open the third control area.

In the third control area (located at the bottom of the plug-in), you can adjust all the parameters in the preset by clicking on and moving the sliders. You can select different groups of parameters to adjust by clicking the but

tons in the row at the top of the third control area (in the example above, I/O Levels, Input Control, Shape, etc.). Some parameters appear as drop- down menus; click the menu to open it, and click on an option to select it.
When you move a parameter’s slider, an arrow appears where the slider’s default position is. To return a preset to its default, click on the arrow or move the slider toward the arrow until the arrow disappears.
The PCM96 Plug-in Control Panel You can manage various network- and software-related aspects of the PCM96 with the Control Panel. To open the Control Panel, click the PCM96ControlPanel icon located in the System Preferences menu on your computer.

Repair Click to re-initialize communication between the PCM96 and your com puter.
PCM96 Communication Click to check the connection status between the PCM96 and your com puter, and to open the PCM96 Setup dialog (described on page 18).
About Click to see the names of the PCM96 development team, and to check for software updates.
Name Assign a name to your PCM96 to identify it on a network.
ID Assign a number to your PCM96 for network purposes.
Audio Source Controls the PCM96 unit’s Audio Source parameter. Select Analog or AES.
Clock Source Controls the PCM96 unit’s Clock Source parameter. Select Internal, AES or BNC.
Clock Rate Controls the PCM96 unit’s Clock Rate parameter. Select 44.1 kHz, 48 kHz, 88.2 kHz, or 96 kHz.
Locate Click to make the PCM96 display flash, so you can easily find the curently selected PCM96 in a large rack full of PCM96’s.
Update Click to automatically update the PCM96 software via the Internet.

PCM96 Setup Dialog When you click the PCM96 Communication button in the PCM96 Control Panel, the PCM96 Setup dialog appears.

Communications Interface Select your computer’s connection to the PCM96 here. Choose from FirewireTM or “Ethernet X,” where “X” is a number corresponding to your computer’s network interface card.
Driver Buffer Setting This control manages latency. Choose from Max Latency (highest latency, least chance of audio droput), Slow (higher latency, less chance of audio dropout), Normal (medium latency, medium change of audio dropout), and DAW (lower latency, more chance of audio dropout).
FireWire Setting Determines if the plug-in streams audio to and from the PCM96, or if the plug-in controls the PCM96 without streaming audio. Choose from “Control And Audio” and “Control Only.”
Cancel Click to cancel any changes you’ve made and return to the PCM96 Control Panel.
Accept Click to save any changes you’ve made and return to the PCM96 Control Panel.
Streaming plug-in configurations When the PCM96 is used as a streaming plug-in, using FireWire I/O, the cascaded options will be unavailable. The increased channel count of the FireWire connection lets you use up to four simple mono or two simple ste reo virtual machines at the same time. There are no cascade configurations available although effects can still be cascaded in the DAW.


This section provides a step-by-step guide on how to properly connect the PCM96 to a Local Area Network (LAN) for several different network archi tectures. The first topology is a simple direct connection using the provided Ethernet cable. The second method describes how to connect and config ure several PCM96 units to create an isolated network using an Ethernet switch with static or with DHCP. This section concludes with some further networking considerations and troubleshooting tips that will help with con necting to your PCM96 via Ethernet. If your application is more than these simple examples we recommend that you involve a trained Ethernet network administrator in the design and commissioning of your system.
Careful planning needs be made before placing a PCM96 on a network that provides any access to the public. Some examples of public access are direct access to the unit from the Internet, an unsecured or weakly secured wire less network, a network jack in a public area that provides network access to the PCM96, or having a computer on the LAN that is not secured so that someone could use it to reconfigure the PCM96. It is highly recommended that the equipment be placed on a protected, isolated network that does not have any connection to the public to prevent unauthorized users from recon figuring the unit. Please refer to the VPN portion of this section for more information. Factory defaults for the Internet Protocol (IP) settings for the PCM96 are as follows:
Auto-IP/DHCP Address: 169.254.x.x (where “x.x” is determined by the PCM96 box numbers) Subnet Mask: 255.255.0.0 Gateway: 0.0.0.0 DHCP Support: Enabled
Overview of TCP/IP Basics
IP address An identifier for a computer or device on a TCP/IP network. Each device in a network has its own IP address to identify it. Example: 126.126.17.42. Networks using the TCP/IP protocol route messages based on the IP address of the destination. An IP address is made of four numbers separated by peri ods. Each number can be zero to 255. The last number should not be a zero or 255. For example, 126.126.17.1 could be an IP address. 126.126.17.0 would not be a valid IP address. A TCP/ IP or IP address has two parts: the NETWORK ID and the HOST ID. The NETWORK ID identifies the network, and the HOST ID identifies either the subnet and device, or just the device if there is no subnet. The subnet mask is a code that indi cates which part of the TCP/IP address is the NETWORK ID and which part is the HOST ID. In subnet-mask code, 255 means “This part of the address is the NETWORK ID”. Example: Suppose the IP ADDRESS of a device is 192.168.xx.yy and the SUBNET MASK is 255.255.x.y. That means, (192.168) is the NETWORK ID. The remaining set of numbers (xx. yy) is the HOST ID. If your network stands alone (it is not part of a larger network) then the HOST ID identifies each device in the network. If your network is part of a venue’s larger network, your network is actually a sub- network or subnet.

Subnet A small network within a larger network. For example, a TCP/IP network might be a subnet of a venue’s network, which could include computers throughout the building, or a network might be divided into subnets. For example, in a large installation, there may be one subnet per rack or room.
DHCP (Dynamic Host Configuration Protocol) This is a protocol for automatically assigning IP addresses to devices on a network. With dynamic (DHCP) addressing, a device might have a different IP address every time it connects to the network. DHCP relies on a DHCP server to assign and manage IP addresses.
Auto IP If DHCP fails, the PCM96 selects a number and looks for collisions. If no collisions are found, the PCM96 accepts that number. If collisions are found, the PCM96 randomly selects another number and tries again.
Connecting the Computer Directly to the PCM96
Assumptions:
Connect the included Ethernet cable to both the PCM96 and the com 1. puter. Apply power to the PCM96 and wait for it to boot. 2. Open the standalone application. 3.
Setup of a Simple Isolated Ethernet Network Using DHCP
Assumptions:
Connect the computer and any PCM96 to the switch hub using normal 1. Ethernet cables. Apply power to all PCM96s and wait for them to boot. 2. With DHCP enabled, the Ethernet switch/router should assign an IP 3. address to each of the devices including your computer. The PCM96 units should come up in the main window. 4.

Virtual Private Networks (VPN) Virtual private networks (VPN) provide an encrypted connection (or tunnel) between networks or between a network and a user over a public network (such as the Internet). Instead of using a dedicated, real-world connection such as a leased line, a VPN uses virtual connections through the public network. The advantage to a VPN is that your computer can be virtually connected to a local network even though it is physically anywhere in the world where you have an internet connection. This can also be done in a safe manner not compromising your local network’s security. If you would like to manage your PCM96 units remotely you should create a secure VPN con nection.
There are many solutions on the market today that provide VPN access. These products offer different features, methods of VPN, complexity of setup and maintenance, as well as varying levels of security. It is beyond the scope of this manual to recommend a VPN solution that will best suit the needs of your network, although you will need a VPN that is capable of passing UDP and TCP traffic (most do). The PCM96 has been tested against several solutions and should work with all VPNs that meet these criteria. Please work with your system administrator and Internet ser vice provider to find a VPN that will best fit your network. The 3Com OfficeConnect Secure Router (model # 3CR860-95) is one solution that has been tested, and is both inexpensive and simple to set up. It provides up to two concurrent VPN connections.
Network Considerations and Limitations
Network Troubleshooting If you are having difficulty getting your PCM96 to show up in your System Architect software, here are some things that you can try to resolve the prob lem.
Software Firewall If the PC that you have installed the System Architect software on has a built-in firewall you need to make sure that you allow the software the abili ty to talk on your network. Try disabling your firewall and then going offline and back online in the System Architect software. If this fixes the problem, refer to your firewall manufacturer’s documentation on how to reconfigure your firewall to allow the System Architect software and/or port 3804 tcp and udp to pass through the firewall.
Ethernet Link Make sure that you have a valid Ethernet connection by looking at the link status lights. Most Ethernet devices will have some kind of indicator that shows the link is present. Check the following connections:
PCM96 device – If there is a valid connection on the PCM96 you will • see a solid green LED.

If you fail to see a link light try removing and reinserting the cable or trying a different, known good, cable. Also, make sure that you are using the cor rect cable.
Ping There is a simple utility built into OS-X that tests the network connection between two devices. The following steps outline how to use this utility.
In the Applications folder, double click the Terminal icon. 1. At the prompt enter ping -c 4 and press 2. Enter. The data should appear something like this:
PING : 56 data bytes 64 bytes from : icmp_seq=0 ttl=62 time=1.118 ms 64 bytes from : icmp_seq=1 ttl=62 time=1.093 ms 64 bytes from : icmp_seq=2 ttl=62 time=1.067ms 64 bytes from : icmp_seq=3 ttl=62 time=1.042ms
--- ping statistics --- 4 packets transmitted, 4 packets received, 0% packet loss round-trip min/avg/max = 1.042/1.08/1.118 ms
If you get a “Reply from” response from the IP address that you were ping ing in a timely manner, it means that you have a valid network connection between the two devices.
If you receive a “No route to host” or “0 packets received” message, this indi cates that your computer is not communicating with the device.

The System Menu lets you adjust several settings in the PCM96. To access the System Menu, press the Select knob while a System Preset is loaded.
The System Menu contains sub-menus and options. Sub-menus contain options and/or more sub-menus. To enter a sub-menu, highlight it with the Select knob and press the Select knob. Options contain values that you can adjust (indicated by a colon followed by a value, for example, “Audio Source: ANALOG”). To adjust an option’s value, turn the corresponding knob: Knob A for an option on the first line, Knob B for an option on the second line, and Knob C for an option on the third line. Press the Back button at any time to save your changes and move one level up through the menus and sub-menus.
Audio Setup The Audio Setup sub-menu contains the following options:
Audio Source This is a global setting that configures the PCM96 to accept ANALOG or AES input.
Clock Source Select your clock source here. Choose from INTERNAL, AES, and BNC.
Clock Rate Select your clock rate here, when the wordclock source is set to INTERNAL. Choose from 44.1HKz, 48KHz, 88.2KHz, or 96KHz.
Analog Setup The Analog Setup sub-menu lets you adjust the following parameters:
Analog Input Level - Increases or decreases the incoming analog signal before it reaches the processor(s). Set to +4dBU or –10dBU.
Analog Output Level - Increases or decreases the outgoing analog signal after it leaves the processor(s). Set to +4dBU or –10dBU.
Analog Type IVTM - Enable or disable the Type IV conversion system here. The dbx® Type IV Conversion System is a proprietary analog- to-digital (A/D) conversion process that combines the best attributes of digital conversion and analog recording processes to preserve the essence of the analog signal when it is converted to a digital format.
Global Mute - Mutes all signals from the PCM96. Set to Muted or Unmuted.
AES Setup The AES Setup sub-menu gives you the status of the following AES infor mation:
Data Validity - “Valid” indicates the data is OK. “Invalid” indicates that the Validity bit was set in a frame of incoming data and that the data attached to it may be corrupted. This bit may also be sent when the

transmitting device is paused.
Mode - Select “Consumer” to send information in S/PDIF format. Select “Professional” to send information in AES format.
Confidence Error - “0” indicates no problem. “1” indicates the PCM96 is detecting excessive jitter or noise on the digital audio line. No data has been corrupted, but corrective action should be taken.
Sample Slip - An unchanging number indicates you are not slipping samples. An increasing number indicates samples are misaligned with the window defined by the Input Source. This may occur when an external master changes sample rate, or when it is just powering up, but should not occur in normal operation.
Bi-Phase Error - “0” indicates no problem. “1” indicates that at least one bit (and therefore at least one audio sample) was corrupted.
CRC Error - “0” indicates no problem. “1” indicates a Cyclic Redundancy Check error in the incoming data.
Parity Error - “0” indicates no problem. “1” indicates that at least one bit (and therefore at least one audio sample) was corrupted.
Machine Config The Machine Config menu lets you configure the PCM96 processor as one, two, three, or four virtual machines in a new preset. Note that once you’ve selected a configuration, you must then populate each virtual machine with a Machine Preset (see page 11 for more information).
Choices include:
Single Mono In Stereo Out Single Stereo Dual Mono Cascade Stereo Cascade Mono Cascade Mono to Stereo Combined Stereo Mono In
For more detailed descriptions of each configuration, see page 14.
MIDI Control The MIDI Control sub-menu lets you adjust the following MIDI-related options:
MIDI Turns MIDI processing on or off.
Device ID Select the connected MIDI device’s ID here. Choose from 0-126.
Base Channel Select the connected MIDI device’s base channel here. Choose from 0-15.

Bank Dump Lets you copy an entire bank of presets from the PCM96 to another device via MIDI. (For a map of banks and presets, see page 29; to see the current preset’s bank number, press Knob C while viewing the Preset screen.) When Bank Dump is highlighted, turn the corresponding B or C Knob to select a bank. Press the corresponding B or C Knob to send the bank to the connected device.
Tempo Control The Tempo Control sub-menu contains the following options:
Tempo Value Set the current preset’s tempo here by turning Knob A, or by pressing the Tap Tempo button at least two times.
Tempo Beat Tempo is expressed in BPM. This control allows you to specify the value of the beat. Eighth, quarter, and half note values are available. If, for exam ple, the rate is 120 BPM, and you select eighth-note here, the tempo will be 120 eighth-notes per minute. If you select quarter-note here, the tempo will be 120 quarter-notes per minute. (The factory default is quarter-note.)
Tempo Source Select INTERNAL to determine the tempo using parameters within the PCM96, or MIDI to set the tempo using MIDI beat clock. Refer to your DAW’s manual to learn how to transmit this value.
Card Config The Compact Flash Setup sub-menu indicates whether a Compact Flash card is INSERTED or NOT INSERTED, and gives you the options to Format (erase) the inserted card by pressing Knob B, or initializing the inserted card by pressing Knob C.
Network Config Here you can set the PCM96 Subnet Mask, IP Address, Gateway, and DHCP information. Turn the Select knob to select a three-digit number (of the DHCP value) and turn Knob A to change the number (or the DHCP value). See the Networking section on page 19 for more details.
HiQnet Config Set the HiQnet Negotiation Mode (Static, Random, or Sequential) and Node Address here. Turn the Select knob to underscore a value and turn Knob A to change the value.
Restore Factory Defaults Returns the PCM96 to its original state as shipped from the factory.

The Machine menu lets you adjust settings for a single virtual machine. To access the Machine menu, press the Select knob while a Machine Preset is loaded.
The sub-menus vary depending on what algorithm is active.
Soft Row Setup This sub-menu lets you assign parameters to a Machine Preset’s soft row. The soft row is the list of parameters that appears below a Machine Preset’s name in the Preset screen. You can easily adjust these parameters with the A, B, and C knobs (press Knob A to see more parameters in the soft row).
I/O Settings Here you can adjust the following settings (depending on the selected pre set):
Wet Dry Mix Adjusts the proportion of wet (processed) signal to dry (unprocessed) signal. Ranges from 0% (all dry) to 100% (all wet). In almost all cases you will leave this at 100%, and control levels on your mixer.
Input Level Controls the amount of signal admitted into the process from the input. Ranges from 0.0dB INV to –90.0dB INV or OFF INV, and from –90.0dB or OFF to 0.0dB.
Output Level Controls the amount of post-mix signal emitted onto the output. Ranges from –90.0dB or OFF to 0.0dB.
Various parameters The sub-menus that appear below the I/O Settings sub-menu depend on the active algorithm. Refer to the Parameters section on page 39 for more infor mation.

The MIDI Control menu is where all MIDI related control is changed. See page 24 for information about the MIDI Control menu.
MIDI Implementation The PCM96 offers MIDI implementation for use with external MIDI hard ware and software controllers. You can connect up to three PCM96 units to a single MIDI controller. You can also slave two or more PCM96 units together by connecting a cable from the MIDI Out port of the master to the MIDI In port of the slave. Additional PCM96 units can be slaved to the master by connecting a cable from the MIDI Thru port of one slave unit to the MIDI In port of the next unit.
The MIDI implementation for the PCM96 is very basic. The implementa tion is fixed, but there is a user interface for modifying basic parts of it.
Nomenclature Numbering in MIDI (channel number and program numbers, for example), can be confusing since some sources start counting from zero and others start from one. This description will start from zero.
How to load presets with MIDI Because of the large number of potential presets in the PCM96, Preset Change messages are used along with the Bank Select extension to provide MIDI preset selection. Controller 32 is used to select the current preset bank. Controller 32 is sent to the system (to select the desired bank), fol lowed by a Preset Change message to select a preset. The Bank values are “sticky,” meaning the PCM96 will remember the Bank values for each MIDI channel. It is not necessary to send a Bank change with each Preset Change unless the Bank has indeed changed.
See page 29 for a bank/preset map. To see a preset’s bank on the PCM96, press Knob C while viewing the Preset screen.
How to assign a Base Channel to the PCM96 The base channel identifies a PCM96 unit to a MIDI device. Add 1, 2, 3, or 4 to the unit’s base channel to identify virtual machines within the unit. You can connect up to three PCM96 units to a single MIDI device.
To assign a base channel to the PCM96:
Press the Back button until the Preset screen appears. 1. Press the Machine button until System View is displayed. 2. Press the Select knob to enter the System Menu. 3. Turn the Select knob until Midi Control is highlighted. 4. Press the Select knob to access the Midi Control Menu. 5. Turn the Select knob until Base Channel is highlighted. 6. Turn Knob B to select the base channel (0-15). 7. Press the Back button twice to return to the Preset screen. 8.
Now the PCM96 unit is identified by the selected base channel, and virtual machines 1, 2, 3, and 4 within the PCM96 are identified by the base chan nel plus 1, 2, 3, and 4, respectively.

Channel Map (how channels map to machines)
Channel Usage Description Base Channel
System Level Use for loading System presets. This is the PCM96 unit’s base channel. The next four channels apply to this PCM96 unit’s virtual machines. Base + 1 Virtual machine 1 Changes parameters in one virtual machine in a System preset on the PCM96 unit
with base channel 0. Use for loading machine presets and changing parameters for machine #1. Base + 2 Virtual machine 2 Changes parameters in one virtual machine in a System preset on the PCM96 unit
with base channel 0. Use for loading machine presets and changing parameters for machine #2. Base + 3 Virtual machine 3 Changes parameters in one virtual machine in a System preset on the PCM96 unit
with base channel 0. Use for loading machine presets and changing parameters for machine #3. Base + 4 Virtual machine 4 Changes parameters in one virtual machine in a System preset on the PCM96 unit
with base channel 0. Use for loading machine presets and changing parameters for machine #4.
Bank Dump The Bank Dump feature lets you copy all the presets in a User bank from one PCM96 to another (or to another MIDI device). Refer to the MIDI Control section on page 24 for information about Bank Dump.
Reverse Bank Dump (Bank “Load”) You can perform a “reverse bank dump” by recording a bank dump to your MIDI sequencer, then playing that sysex back to the PCM96 to restore the bank.
Continuous Controllers All PCM96 soft row parameters can be controlled with single, 7-bit control lers. Each parameter is controlled with the full controller range, regardless of the parameter range. For example, if the controller is at the midpoint of its range (64), the parameter will also be at the midpoint of its range no matter what the actual number.
Continuous Controllers range from 0 to 127. If the parameter range is less than 127, then a small controller change might not result in a parameter update. But the entire range of the parameter can still be accurately con trolled. In addition, if the actual range of the parameter is greater than 127, MIDI control might be somewhat coarse. This is most noticeable with large delays.
When MIDI is enabled, the PCM96 automatically sends MIDI messages through the MIDI Out port for soft row parameters and preset loads when ever those actions are performed via the front panel controls.

Soft Row parameter/MIDI CC Map

Soft Row Parameter MIDI CC Parameter #1 CC 48 Parameter #2 CC 49 Parameter #3 CC 50 Parameter #4 CC 51 Parameter #5 CC 52 Parameter #6 CC 53 Parameter #7 CC 54 Parameter #8 CC 55
Bank Presets Bank # Mono Internal Flash Bank 1 Mono User Onboard Flash Category Presets 1 – 128 72 Mono Internal Flash Bank 2 Mono User Onboard Flash Category Presets 129 – 256 73 Stereo Internal Flash Bank 1 Stereo User Onboard Flash Category Presets 1 – 128 74 Stereo Internal Flash Bank 2 Stereo User Onboard Flash Category Presets 129 – 256 75 System Internal Flash Bank 1 System User Onboard Flash Category Presets 1 – 128 76 System Internal Flash Bank 2 System User Onboard Flash Category Presets 129 – 256 77 Mono Compact Flash Card Bank 1 Mono User Compact Flash Category Presets 1 – 128 100 Mono Compact Flash Card Bank 2 Mono User Compact Flash Category Presets 129 – 256 101 Mono Compact Flash Card Bank 3 Mono User Compact Flash Category Presets 257 – 384 102 Mono Compact Flash Card Bank 4 Mono User Compact Flash Category Presets 385 – 512 103 Stereo Compact Flash Card Bank 1 Stereo User Compact Flash Category Presets 1 – 128 104 Stereo Compact Flash Card Bank 2 Stereo User Compact Flash Category Presets 129 – 256 105 Stereo Compact Flash Card Bank 3 Stereo User Compact Flash Category Presets 257 – 384 106 Stereo Compact Flash Card Bank 4 Stereo User Compact Flash Category Presets 385 – 512 107 System Compact Flash Card Bank 1 System User Compact Flash Category Presets 1 – 128 108 System Compact Flash Card Bank 2 System User Compact Flash Category Presets 129 – 256 109 System Compact Flash Card Bank 3 System User Compact Flash Category Presets 257 – 384 110 System Compact Flash Card Bank 4 System User Compact Flash Category Presets 385 – 512 111
Bank/Preset Map

Command 0: Request Preset Dump When this command is received by the PCM96, it will respond with a preset dump of the requested preset. If the preset does not exist, the PCM96 will not respond. Only presets from User banks may be requested. Factory banks will not be transmitted.

Byte Definition Comments 0xF0 Sysex message 0x06 Lexicon® Manufacturer ID 0x__ Product ID 0x__ Device ID 0x00 Command Request Preset Dump 0x02 Size LSB 0x00 Size cont 0x00 Size cont 0x00 Size MSB 0x__ Bank Bank in which requested preset lives. 0x__ Preset Preset ID 0xF7 EOX
Command 1: Preset Dump This sysex is transmitted by a MIDI sequencer or by PCM96. The PCM96 may transmit this dump in response to a request or by means of a front- panel action. The PCM96 receiving this dump will store the encapsulated preset data in the designated location.
Byte Definition Comments 0xF0 Sysex message 0x06 Lexicon Manufacturer ID 0x__ Product ID 0x__ Device ID 0x01 Command Preset Dump 0x__ Size LSB. Size is variable and is not shown in this example 0x__ Size cont 0x__ Size cont 0x__ Size MSB 0x__ Bank Bank in which the preset is to be placed. 0x__ Preset Location in the bank where the preset is to be placed Preset data Nibbleized preset data. 0xF7 EOX

MIDI SysEx Implementation

Command 2: Request Preset Bank Dump When this command is received by the PCM96, it will respond with a series of preset dumps for all presets in the bank. Blank presets will be transmitted in a special form. Only presets from User banks may be requested. Factory banks will not be transmitted.
Byte Definition Comments 0xF0 Sysex message 0x06 Lexicon® Manufacturer ID 0x__ Product ID 0x__ Device ID 0x02 Command Request Preset Bank Dump 0x01 Size LSB 0x00 Size cont 0x00 Size cont 0x00 Size MSB 0x__ Bank Bank to fetch 0xF7 EOX



Chamber (Stereo and Mono) Chamber is a complex miniature-space effect resembling an echo chamber at its smaller settings and, at its larger ones, a small performance space with a more rapid build-up of reflection density than a hall. Reverberant tails are randomized.
Random Delay (Stereo and Mono) Random Delays provide no-holds-barred control over delays. These algo rithms feature one delay line per input channel. Each delay line has two out puts, called “voices.” Each voice has independent delay time (up to and over 9 seconds, plus an additional second provided by the randomizers described in the next paragraph), output level, feedback control, filtering (independent filters for feedback and output), and panning. Random Delays have the same diffusion controls as Dual Delays.

In addition to this basic voice architecture, Random Delays feature four randomizers that provide up to one second of additional delay time for each voice. Voices can be assigned to either randomizer, or to no randomizer at all.


Random Delays are similar to Simple Delays, but are especially useful for:
Hall (Stereo and Mono) A hall is the principal venue for classical ensembles, but has proven to be useful for all types of music. A hall is comparatively large, with wall-to-wall distances that are typically several tens of meters. Smaller halls may be used for smaller ensembles. The characteristic sound of a hall includes very low initial reflection density, with little reflection energy before 60-100 mil liseconds. Density buildup is more gradual, because of the larger distances between reflecting surfaces. Reverberation time is somewhat longer as well. Finally, in most halls lower frequencies reverberate longer than higher fre quencies.
This new hall algorithm shares these basic characteristics with Random Hall and Concert Hall, but is smoother with a more even decay. Its initial density is also lower than Random Hall so it may be a better choice when the rever beration needs to be unobtrusive.

Random Hall (Stereo and Mono) Random Hall is a hall effect with gradual build-up, well suited to complex sounds like orchestral music. Its reverberators change over time in controlled random ways to avoid the buildup of tinny, grainy, metallic, or other color ations. The modulation can be noticeable and is often a desirable effect.
The early reflections are user adjustable in amplitude and delay. Some skill is needed to set useful reflection patterns. The pattern can be expanded or contracted in time using the “Delay Master” control, and the overall level of the pattern can be set with the “Early Level” control.
A hall is the principal venue for classical ensembles, but has proven to be useful for all types of music. A hall is comparatively large, with wall-to-wall distances that are typically several tens of meters. Smaller halls may be used for smaller ensembles. The characteristic sound of a hall includes very low initial reflection density, with little reflection energy before 60-100 mil liseconds. Density buildup is more gradual, because of the larger distances between reflecting surfaces. Reverberation time is somewhat longer as well. Finally, in most halls lower frequencies reverberate longer than higher fre quencies.
One of its charms is a bit of irregularity in the decay. In some cases (very small rooms with precisely-pitched instruments), this modulation may not be the best choice. But in general, this is a time-tested reverberator.
Plate (Stereo and Mono) The Plate programs mimic the sounds of metal plates, with high initial dif fusion and a relatively bright, colored sound. For this reason, they are good choices for percussion. They are designed to be heard as part of the music, mellowing and thickening the initial sound itself. The Plate sound is what many people associate with the word reverb, and it is useful for all popular music.
Dual Delay (Stereo and Mono) Dual Delay feature two delay lines for each input channel. Each delay line has a single output or “voice.” Each voice has independent delay time (up to 2 seconds), output level, feedback control, filtering, and panning. The feedback path includes highpass and lowpass filters. In addition to this basic voice architecture, Dual Delays feature parameters that provide expand ed diffusion controls.


Resonant Chords (Stereo and Mono) The Resonant Chord algorithm uses impulsive energy at the inputs to excite six resonant voices (notes). The level, pitch, duration, and high-frequency cutoff of the overtones for each voice are separately controllable. Each voice can be panned independently. The voices resonate to some degree with any input, but the most effective excitation contains all frequencies, like percus sion. Other instruments may give a quality of tonal ambience in which cer tain notes rise ethereally from the background. The output of the resonator is then fed into a stereo plate reverb effect.

The two algorithms differ in the way pitches are assigned to the resona tors. In Res1>Plate, pitches are assigned to the six voices chromatically, in a

round-robin. For example, if MIDI note numbers are used to assign pitch, the resonators will constantly be re-tuned to the pitches of the last six MIDI notes received. (This can produce an effect similar to playing a piano with the sustain pedal depressed.) In Res2>Plate, pitches are assigned to the six resonators diatonically, harmonized with the key, scale, and root of your choice. If MIDI note numbers are used to assign pitch, the resonators will constantly be re-tuned to harmonize with the incoming notes.
Chorus/Flange (Stereo only) Chorus/Flange is quite similar to other delay algorithms in the PCM96. It has four delay voices per channel, each delay voice having over 9 seconds of delay. The delays may be independently panned and filtered. The difference is in the modulation aspect. The same LFO modulators are available as in Random Delay, but the voices react differently. In Random Delay, the voices move abruptly. In Chorus/Flange, they move very gradually, with notice able (and desirable) pitch effects as they move. For the chorus effect, the voices move somewhat independently, yielding a thickening effect without too much filtering. For the flange effect, voices are generally paired at close intervals. As they move, a noticeable comb-filtering takes place due to can cellation. The voices are often fed back, nearly to the point of instability.
Concert Hall (Stereo only) This is a recreation of one of Lexicon®’s oldest algorithms. It was an essen tial part of many of the mixes of the late seventies and eighties. It is a less- dense reverb, allowing it to add lushness to a mix without stepping on the dry source material. It also has quite noticeable modulation, causing strong pitch effects at higher settings. The reverb tail has a life of its own, desirable in pop music, less so in jazz or classical applications.
Room (Stereo and Mono) A room is similar to a reverb in that it is used to create the illusion of space. However it differs in important ways. A room is comprised of a selectable early impulse taken from actual room measurements. There are several cat egories of responses, including small rooms, large rooms and odd rooms (impulses from unconventional sources). There are parameters to allow adjustments to this response, including scaling and reversing the response. In many cases this is sufficient. A reverb tail can be added to the room by means of an included small reverb algorithm.
Lexicon reverbs are renowned for smooth tails and controlled frequency response. However, in many cases the earlier components are more impor tant. This may be true for some forms of popular music and is even more true for post-production. In these cases, specific types of spaces need to be invoked for convincing dialog and effects.
Signal Generator This algorithm is used to generate test signals. These signals may be used both for building presets and for testing aspects of recording studio function ality.



The parameters The PCM 96 contains hundreds of presets, covering just about every pos sible need. But you can refine and customize any preset by adjusting its parameters. Parameters are the building blocks within each preset that deter mine how it sounds and behaves.
Each algorithm contains a set of parameters, and a variety of those param eters (sometimes from more than one algorithm) are combined to create a preset. You can edit a machine preset’s parameters via the A, B, and C knobs (which control the Soft Row; see page 11 for more information), or you can access parameters located in sub-menus via the Machine menu(see page 26 for more information about the Machine menu). You can edit a system preset’s parameters by accessing them via the preset’s sub-menus, or you can edit the parameters in the individual machine presets contained within the machine preset.
Below are all the algorithm parameters you can edit in the PCM 96. Note that sometimes parameter names are abbreviated when they appear onscreen (for example, Delay Level Master may appear as DlyLvlMaster), and they may have prefixes indicating what channel they control (for example, Level may appear as RightInLvl, or OutLvl).
To see the parameters in context, refer to the charts beginning on page 47.
Bandwidth This parameter lets you set the bandwidth of a multimode filter. Bandwidth is specified in octaves or fractions thereof.
Bass Boost (Room) This parameter is closely tied to the Bass Crossover parameter. It controls the boost (or cut) of signal below that crossover.
Depending on the type of impulse response selected, the listener may become aware of an excess or insufficiency of low frequency output. This parameter may be used to correct the frequency response.
Bass Crossover (BassXOver) The Bass Crossover parameter is closely tied to the BassRT parameter. It rep resents the frequency below which BassRT has an effect. Note that there are two of these parameters in the Room algorithm. One is tied to BassRT, the other is found in the Pattern settings menu and affects the BassBoost.
BassRT This parameter controls bass reverb time. It is closely associated with the Bass Crossover and MidRT parameters. BassRT is a multiple of MidRT that applies to signal below the frequency described by Bass Crossover. If BassRT is less than 1.0, then the low frequency part of the reverb tail will be shorter than the midrange part. If BassRT is greater than 1.0, then the low frequen cy part of the tail is longer.

Category (Room) This parameter lets you select a specific category from which a room response may be chosen. Changes here have a direct effect on the Pattern Selector parameter.
Chorus Depth (Concert Hall) This parameter controls the amount of randomization of the chorus tap. Higher values are generally preferred in order to minimize reverb coloration. Pitch effects may result and are closely tied to the Reverb Chorus Rate parameter.
Chorus Rate (Concert Hall) This parameter controls the rate at which the reverb chorus is run. Low values may cause a barely-noticeable undulation. Higher values will cause noticeable wobble in fixed-pitch instruments such as piano. It is closely tied to the Reverb Chorus Depth parameter.
Definition Definition controls the density of some reverbs. Higher values result in lower density.
Delay Feedback Master Controls all delays in the algorithm. Each voice has its nominal feedback gain adjusted by this percentage.
Delay Level Master Controls all delays in the algorithm. Each voice has its nominal gain value adjusted by this percentage.
Delay Time (Echo Delay) Delay time defines the time offset of a delay voice in milliseconds or in fractions of tempo (quarter note, eighth note), which is defined by the tap tempo or by midi tempo. It is used in many of the algorithms, not just the delays. In all cases, it does the same thing.
Delay Time Master Controls all delays in the algorithm. Each voice has its nominal delay time adjusted by this percentage.
Delay Wander This parameter determines the amount of additional delay that the LFO process can add to a voice’s offset.
Diffusion Input diffusion is the first part of processing for any signal entering a reverb or delay. It can be described as a smearing or softening of the signal and is typically used to lessen the impact of strong transients.
Bass Crossover (Bass XOver) (Room) Thus parameter is closely tied to the Early Bass Boost parameter. It repre sents the frequency below which early bass boost has an effect.
Feedback This controls the amount of echo output that is fed back to the input of the echo buffer.

The actual feedback level is modified by the Master Echo Feedback param eter, if present. The master value is a percentage (0-100%) that is applied to the Echo Feedback level.
Feedback Diffusion Feedback Diffusion is similar to Input Diffusion, except that it is applied to a delayed signal that is being added back into the input.
Feedback Level This parameter determines the feedback level for a particular voice. It is con trolled independently of the voice’s output level.
Feedback Pan Routes the post-filter delay voice back to the inputs of the delay lines.
Frequency This parameter lets you set the cutoff frequency of the multimode filter. The audible effect of this is determined by the Type parameter.
Front Early Level This parameter acts as a master control for any early signals going to the out put channels. Early signals include echoes, reflections, and the room reflec tion patterns.
Infinite This parameter captures the reverb tail as an infinite loop. This may be use ful in music, where a note or chord can be extended. It is also useful in post- production for creating ambience backgrounds.
Input Level Input Level controls the amount of signal admitted into the process from a single input channel.
Input Pan Routes the signal from an input channel into the algorithm in such a man ner as to alter its apparent location.
Level This parameter acts as a master control for reverb signals going to the output channels. It is used for all reverbs.
LFO Rate Set the speed of an LFO in Hz.
LFO Waveform Type Set the shape of the wave the LFO will follow.
Master Echo Delay Controls all echo voices in the algorithm. Each echo delay has its nominal time adjusted by this percentage.
Master Echo Feedback Controls all echo voices in the algorithm. Each echo feedback has its nomi nal gain adjusted by this percentage.

Master Reflection Delay (Reflection Time Master) Controls all reflection delays in the algorithm. Each reflection delay voice has its nominal delay time adjusted by this percentage.
MidRT MidRT is the mid frequency reverb time. As such, it is one of the primary controls affecting the length of the reverb tail. At low values, it models a space with absorbent walls—a signal won’t bounce many times before it dis sipates. At high values, the walls are flat and extremely reflective. A signal lives a long time before dying away.
The parameter most closely associated with MidRT is Size. A large room size with a small MidRT can easily have the same decay time as a small room with a large MidRT. The value that is actually displayed is an approximate reverb time based on both of those values.
Mix (Wet Dry Mix) Mix is the proportion of wet (processed) signal to dry (unprocessed) signal.
Output Level Output Level controls the amount of post-mix signal emitted onto a channel of output.
Pan Routes the post-filter delay voice across the left-right soundstage.
Pattern Selects a space available in the selected Category (see Category parameter).
Reflection Delay (Delay Time) A reflection delay is a delay tap taken from one of the inputs and sent to one of the outputs. It is often called a delay voice. Depending on the algorithm, there may be one or more reflection delays for each input channel. Some of the delays may mix their outputs to the same channel (left to left) and some may go cross-channel (left to right).
Reflection Gain (Level) Each Reflection Delay voice also has a gain value. This gain is controlled by the Reflection Gain parameter.
Resonance This parameter determines at which frequency the delay voice resonates.
Resonance Detune Master Controls detuning of all voices in the algorithm. Each voice has its nominal detune. adjusted by this percentage. Includes a built-in ducker that attenu ates the delay output whenever signal is present at the input. This can be used to keep the original signal from being muddied up by delay repeats.
Resonance Filter Master Controls all voices in the algorithm. Each voice’s resonator has its nominal cutoff frequency adjusted by this percentage.

Resonance Master Controls all voices in the algorithm. Each voice has its nominal resonance adjusted by this percentage.
Resonance Tuning Master Affects all voices in the algorithm. Each voice has its nominal resonance adjusted by this value. In the musical world, the tuning reference is A=440. This means that the note A (above middle C) is equivalent to 440 Hz. Changing the master tuning causes all notes to be sharp or flat.
Resonator Detune This parameter acts as an adjustment to the specified frequency for the voice’s resonator. The calculation of cents yields a ratio which is used to modify the specified frequency of the voice. This parameter is modified by the Master Detune parameter.
Resonator Filter Freq This parameter controls a lowpass filter inside the resonator.
Resonator Frequency This parameter determines at which frequency the delay voice resonates. The action of this parameter is determined by the state of the Resonance Mode parameter. When a frequency is calculated for this parameter, it must then be affected by the value of the Master Tuning parameter.
Reverb PreDelay (Predelay) This is a delay that’s added to the diffused signal before it enters the main part of the reverb. For all intents, it may be considered as delay that is added to the reverberated signal. It is used to temporally separate the reverb from the dry signal.
Reverb Spin (Spin) This is usually simply called spin. It controls the speed of the reverb random izer. Spin is also connected with the Reverb Wander parameter
Reverb Time Hi Cut This parameter, also known as Hicut or RTHC is a low-pass filter in the recirculating part of the reverb. It represents a frequency above which the tail dies away more quickly. In some ways, it represents the opposite end of the scale from BassRT, and may be considered an analog of air absorption. It is also closely tied to the Hi Cut Damping parameter.
Reverb Wander This parameter (also known as just Wander), along with Reverb Spin, is used to control the reverb randomizer. It controls the maximum size of random izer steps, and is expressed in a time value (typically milliseconds).
Room Size Room Size corresponds roughly to the length of the longest wall of a rect angular room. In a more general sense, it corresponds to the overall dimen sion of some mythical space. This space has a geometry that causes sound

to bounce around. When the room size is small, the “walls” of this space are closer together and the resultant reflection density increases. When the room size is large, that density decreases. The most natural reverbs use room sizes that vary from about 24 meters to 45 meters or so, but there are many useful reverbs that are outside of this range. There is a relationship between this parameter and the MidRT parameter. Please see the MidRT parameter for clarification.
RtHC Damping The damping parameter is closely tied to the RTHC parameter. It controls the strength of the hi frequency absorption and has three values: Light, Normal, and Heavy. The normal value gives filter response identical to previ ous Lexicon® reverbs. The other values should be self-descriptive.
Scale This parameter is used to modify the overall time of the selected early impulse. It is a multiplier that goes from 0.5x to 2.0x. The actual time of the responses varies from response to response. The Early Scale parameter simply scales that amount of time. It’s fair to describe this a “rubber-banding” the impulse response.
Selected LFO This parameter determines which of the available LFOs may be used to con trol a voice. The voice may use the LFO output or the inverted LFO output.
Shape (Early Shape) The Shape parameter is closely tied to the Spread parameter. Shape controls how energy is injected into the reverberator. A low value means that sound enters the reverb at the beginning of the spread window. A high value means that most sound moves into the reverb at the end of the spread window. A value somewhere in the middle means that sound enters the reverb evenly across the spread window.
Shelf This parameter effects all filter types. It allows a certain amount of unfiltered audio to be combined with the filtered audio. This effectively lowers the effect of the filter. Another way of looking at it is that it lessens the normal filter slope of 12 dB per octave. Unlike the traditional biquad filter, the shelf is effective for all filter forms.
Signal Event Freq Changes the rate of discreet signals from the signal generator. This only has an effect when the signal type is set to sweep tones or pink click.
Signal Frequency Changes the frequency of the signal generator sine wave. This only has an effect when the signal type is set to sine wave.

Signal Type Selects the type of signal to be created by the signal generator. The types of signal are:
Spread (Early Spread) The spread parameter is closely tied to the Shape parameter. Spread is a win dow of time during which a signal is injected into the reverb. Shape controls just how the signal is injected during this window.
Tail Width This parameter is present in all stereo reverbs and rooms. The reverb tail (all components of the reverb except for early reflections, etc.) is passed through a simple 2x2 matrix. This provides an encoding of the tail that dramatically changes its spatial characteristics. The tail can be changed to feel narrower (even down to mono) or wider than normal stereo. There are values for the parameter to encode the tail in such a way that it decodes into surround channels.
The parameter operates in the range of 0 to 360 degrees, with an incremen tal change of 1 degree. The matrix uses Sine/Cosine rules so that power dis tribution remains constant. This may be acceptible—even highly desirable— but the mix engineer must fully understand the process and its implications.
This is a powerful tool for audio whose release format is two-channel. It is not useful in any other format. Formats include compact disc and radio/tele vision broadcast. Some of these effects are clear and noticeable without any sort of decoder. Many are even more dramatic when a decoder is in place, such as in a home theater.
Tap Slope This is an extremely subtle parameter and is useful in only a couple of cases:

Type This parameter lets you configure a filter as any of 4 basic types, in order:
The filter provides a subset of filter types available to a Biquad filter.
Wet Dry Mix Wet Dry Mix is the proportion of wet (processed) signal to dry (unpro cessed) signal.


















Analog Inputs Connectors Two, Female XLR Impedance 20K Ohm, balanced Level (for 0 dbFS) +4dBu mode: +20dBu –10dBV mode: 8.2dBu Freq Response @96K 20Hz to 40KHz, +0/–3dB A/D Conversion 24 bits A/D Dyn Range >112 dB unweighted, 115dB A-weighted THD
Analog Output Connectors Two, Male XLR Impedance 30 Ohm, electronically balanced Level (at 0 dBFS) +20dBu Freq Response @96K 20 Hz - 20 kHz, +/- 0.25 dB 20Hz - 40kHz +0/–3dB D/A Conversion 24 bits
D/A Dyn Range 112 dB unweighted, 115 dB A-weighted THD
Digital Audio IO Connectors One Male XLR Output One Female XLR Input Two FireWireTM Ports Format AES/EBU/FireWire (400Mb) Word Size 24 bits
Sample Rates Internal 44.1kHz/48kHz/88.2kHz/96kHz Accuracy within ±50ppm
External 44.1kHz/48kHz/88.2kHz/96kHz Lock Range ±2% of nominal
44.1 kHz 48 kHz 88.2 kHz 96 kHz A/D 1.41 1.28 1.25 1.13 A/A 1.64 1.51 1.28 1.18 D/A 1.48 1.36 1.24 1.14 D/D 1.23 1.12 1.15 1.07
Synchronization TTL Word Clock Input * 75 Ohm, BNC *Falling edge marks start of frame
Propagation Delays (milliseconds)

Clock Jitter Intrinsic Exceeds AES3 Amendment 1 Jitter Gain Exceeds AES3 Amendment 1
Control Interfaces MIDI ** In/Out/Thru
Algorithms Chamber Stereo and Mono Random Delay Stereo and Mono Random Hall Stereo and Mono Plate Stereo and Mono Dual Delay Stereo and Mono Resonant Chords Stereo and Mono Chorus/Flange Stereo only Concert Hall Stereo only Room Stereo and Mono Hall Stereo and Mono Signal Generator
Storage Media Type I Compact Flash Can hold up to 1536 user presets
Machine Configurations 44.1K/88.2K Two Mono (Super-mono capable) Single Stereo (Super-stereo capable) Two Cascaded Mono pairs Cascaded Stereo Two Mono cascaded into single Stereo Dual mono-in/stereo-out with combined outputs Single Super Stereo Two Stereo Dual Super Mono Four Mono Two Mono and One Stereo
Internal Hard Disk Storage Internal non-volatile Flash. Can hold 768 user presets.
Power Requirements 100-120 / 220-240 VAC 50-60Hz, 20W max Connector 3-pin IEC
**supports program change

Dimensions Rack Units 1U Size 19.0” W x 1.75” H x 12.5” D (483mm x 44.5mm x 317.5mm)
Weight 8.65 lbs
Regulatory Approvals FCC Class A CE EN55103-1, EN55103-2 UL UL1419 cUL C22.2 TUV EN60065
Environment Operating 15° to 35° C Storage –30 to 70 °C Humidity 75% relative humidity max


X X Note Number True Voice X X Velocity Note ON Note OFF
Local ON/OFF All Notes OFF Active Sensing System Reset
Mode 1: OMNI ON, POLY Mode 2: OMNI ON, MONO O : Yes OX : Selectable Mode 3: OMNI OFF, POLY Mode 4: OMNI OFF, MONO X : No



Harman Music Group 8760 South Sandy Parkway | Sandy, Utah 84070 U.S.A. Phone: (801)-568-7660 | Fax: (801)-568-7662 PCM96
Questions or comments? Email us at: customer@lexiconpro.com or visit us online at www.lexiconpro.com
Copyright 2008 Lexicon Professional® Part# 18-0711-B
Pages referenced in this manual — manufacturer, support and downloads.
What the fault codes shown on the display mean and how to clear them.
| Code | Meaning | Fix | |
|---|---|---|---|
| OR255 | For example, 126.126.17.1 could be an IP address. 126.126.17.0 | p.25 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.