Electronic Countdown Timer Switch Cat. No. LTB15, LTB30, LTB60, LTB02, LTB12 Lighted
20A Resistive/Inductive, 1800W Incandescent, 1HP 120VAC, 60Hz INSTALLATION INSTRUCTIONS
TOOLS NEEDED TO INSTALL YOUR TIMER SWITCH
Step 4b cont'd
Timer Switch
Slotted/Phillips Screwdriver Electrical Tape Pliers Pencil Cutters Ruler
Coordinating Remote Switch (no LED)
Changing the color of your device: Your device may include color options. To change color of the face, proceed as follows:
WH
BK
Step 3 Preparing and connecting wires: Pull off pre-cut insulation from timer switch leads. Make sure that the ends of the wires from the wall box are straight (cut if necessary). Remove insulation from each wire in the wall box as shown:
(u n used )
RD
Line 120 VAC, 60Hz
(u n used )
Strip Gage (measure bare wire here) Cut (if necessary)
5/8" (1.6 cm)
Line up tabs and press in sides one at a time to attach
Push in side at tab to release
For non-standard wiring applications, refer to
Wire Nut and Connector Size Chart
+
BK
WH
Identifying your wiring application (most common): NOTE: If the wiring in your wall box does not resemble any of these configurations, consult an electrician.
RD YL/RD
Single Pole 1. Line (Hot) 2. Neutral 3. Ground 4. Load
3-Way 1. Line or Load (see IMPORTANT instruction) 2. Neutral 3. Ground 4. First Traveler – note color 5. Second Traveler – note color.
Insulating label: This wire is used in 3-way installations only. For single pole installations, do not remove this insulating label.

3-Way Wiring with Vizia + Matching Remote Switch (w/LED) Application:
TROUBLESHOOTING
1. To turn the load ON press one of the timer buttons. The green LED adjacent to that button will illuminate and the timer will begin to countdown for the selected timer period. 2. To select a different countdown time press the button corresponding to the desired time. The LED adjacent to that button will illuminate and the timer will begin countdown from the new selection. 3. To turn the load OFF press the OFF button or wait until the selected amount of time has passed. The LED adjacent to each button will extinguish as time passes to the next preset level.
WH
Timer Override To override the Timer countdown press and hold the top button for several seconds. The locator LED will turn amber to indicate the EXTENDED ON state. In this state the timer will automatically turn OFF after 24 hours. To exit the EXTENDED ON state press any of the timer buttons or the OFF switch.
Timer Switch Matching Remote Switch (with LED)
ADVANCED PROGRAMMING FEATURE
Techline at 1-800-824-3005 or visit Leviton’s
Hot (Bla c k )
WH
BK
Timer Select Mode - You can change the time outs on your timer without buying a new device!
BK
Covered by one or more US & Foreign
Timer Switch Mounting: TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Your timer can be programmed to function as any of the timers in the table below:
Patents and patents pending © 2009 Leviton Manufacturing Co., Inc. All Rights Including Trade Dress Rights Reserved
Step 6
NOTE: The timer switch must be installed in a wall box that has a Load connection. The matching remote switch must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote switch needs to be added as shown. If you are unsure about any part of these instructions, consult an electrician. NOTE: Maximum wire length from timer switch to all installed remote switches cannot exceed 300 ft (90 m).
Installation may now be completed by tightening mounting screws into wall box. Attach wallplate.
Restore Power: Restore power at circuit breaker or fuse. Installation is complete.
To select different on times please follow the subsequent steps: 1. Press and hold the 1st and 3rd timer buttons to enter Select Timer Mode. 2. The current active Timer LED will flash green to indicate the device is in Select Timer Mode. 3. Press the button (from the table above) corresponding with the time outs you desire. 4. The new Timer button will briefly flash to demonstrate the timer mode chosen. 5. Pressing the OFF button will save programming and exit programming mode. The timer will also exit programming mode automatically if no buttons are pressed for 3 minutes.
Button 1 - Longest ON time
Multi-Location Control The Timer can be turned ON or OFF from any of the Vizia +® Remote Switch locations. The default ON time when a remote is pressed to turn the load ON will be the last countdown time chosen. The timer can be controlled from up to 10 locations using Vizia + Coordinating Remote Switches or up to 5 locations using Vizia + Matching Remote Switches.
Button 2 LED indicator
Button 4 - Shortest ON time
PK-93796-10-00-2A © 2009 Leviton Mfg. Co., Inc.
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, NY 11747. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Owners and our team usually reply within a day — and your question helps the next person too.