System Manual

Rev.A00

Introduction 1 System Design 1 Theory of Operation of the LAVA HQ-ST Link 1 Primary Hardware Components of the HQ-ST System 2 ST Plus 2 HQ Plus 3 Secondary Hardware Components of the HQ-ST System 4 HQ Remote Console 4 HQ Remote Poller 4 Software Components of the HQ-ST Link System 5 HQ Basic Software 5 ST Plus Configuration Console 5 LAVA Ether Link Manager Utility 5 LAVA HQ Plus Install 6 Equipment Needed 6 General 6 METHOD #1: Headquarters Installation using HQ-Basic (recommended method) 6 METHOD#2: Headquarters Installation using Ether Link Manager and the Web Page 9 LAVA ST Plus Install 12 Equipment Needed 12 General 12 Installation of ST Plus Devices at the ECR Equipment Sites 12 ST Configuration Console: Operation 16 Hardware Connection 16 Software Connection 16 HQ Basic: Operation 19 Hardware Connection 19 Software Connection 19 APPENDIX A: Installation Checklist 21 APPENDIX B: Verify Access to the Internet from the LAN 23 APPENDIX C: Check that the LAN Provides DHCP Setting Configurations to Devices on the LAN 24 APPENDIX D: Check that the Selected HQ Site has a STATIC WAN IP Address 25 APPENDIX E: Test that the HQ Site is Properly Set Up and Working: HQ Plus Installed 26 APPENDIX F: Test the End-to-End HQ-ST Link Communications: HQ and ST Installed 27 APPENDIX G: Troubleshooting 28 APPENDIX H: Master Reset to Factory Defaults 30 APPENDIX I: Installing the HQ Plus on the PC as a (TAPI) Modem 31 APPENDIX J: Windows Installation Tools for Use with HQ Plus and ST Plus Devices 32 Web Page Interface on HQ Plus and ST Plus 32 PING Function 32 IPCONFIG Function 32 HyperTerminal 32 TELNET 32
Rev. A00 HQ-ST System Manual Page i

The LAVA HQ-ST Link consists of ST Plus devices installed at each store. The ST Plus devices communicate with an assigned and dedicated HQ-Plus device at the head office. The ST Plus devices are attached to the cash register(s) in each store, and to the store's Internet connection. Polling software running on a head office computer can poll each cash register, via the HQ Plus.
The system is supported by the included ST Plus Configuration Console application, which makes configuring ST Plus units simple, and at the head office by the HQ Basic application, which shows the connection status of ST Plus devices in stores.
The system is also enhanced by the HQ Plus Remote Console and the HQ Plus Remote Poller, hardware interfaces that enable an installer or owner to perform head office tasks from other locations.
A LAVA HQ-ST Link provides reliable "always on-line" communication path between remote/distributed ST Plus devices and a centrally located HQ Plus device. The ST Plus establishes a TCP/IP connection to the IP address:TCP port of a designated HQ Plus. This connection then provides the HQ Plus with the current IP address:TCP port of the ST Plus.
Whenever the ST Plus is reset or powered up, the ST Plus establishes this connection, and expects the HQ Plus to send an "I (HQ Plus) still see You (ST Plus)" packet to the ST Plus once every three minutes at a minimum. If the ST Plus does not receive this “keep-alive” message from the HQ Plus, the ST Plus will reset and try to re-connect to the HQ Plus. Similarly, in the event of some change at the ST Plus's site, the ST Plus will re-connect to the HQ Plus. Typical incidents could be: power cycling off and on, an IP address change of the ST Plus due to dynamic IP address re-assignments , re- location of the ST Plus, initial installation of the ST Plus, interruption of Internet service, and so on.
The HQ-ST System provides a "telephone modem-like communications environment" to the equipment connected at both ends. However, the data path between the ST Plus and HQ Plus is over Ethernet using TCP/IP communications. The Ethernet TCP/IP communications are used only as the communications medium between the HQ Plus and the ST Plus devices, and are "invisible" to the serial side data I/O activities at the HQ Plus and ST Plus devices.


The ST Plus and HQ Plus are the two essential hardware components in an HQ-ST Link. ST Plus devices, attached to ECRs in stores, connect to their assigned HQ Plus device located at a head office.
The ST Plus is a device operates as a TCP/IP Raw Client, with the intention of providing a store-side serial-to-Ethernet interface to an ECR or other similar device.
The ST Plus provides a serial port with the I/O characteristics and pin-out of a USR-type modem with a DB-25F connector. To make a serial-to-serial connection from the HQ Plus's serial port to the ST Plus's serial port the originating equipment connected to HQ Plus (typically a computer running ECR polling software) sends a dialing string (ATDT5551234, for example) that causes a connection to be made to the serial port of the specific ST Plus (in this example, known as 5551234) to which the receiving equipment (the ECR to be polled) is connected.




The HQ Plus operates as a TCP/IP Raw Server, with a known IP:Port address. The HQ Plus is intended to provide a head- office serial-to-Etherenet interface for a polling application to access remotely located device to be polled.
The HQ Plus provides a modem-like serial interface (US Robotics (USR) command set, DB-25F connector), that is used by an external device such as a PC to make a "telephone - modem" call (that is, using a conventional modem dialing string of the format: ATDT5551234).
The HQ Plus comes in versions that support up to 126, 30, or 8 ST sites.

A set of LEDs on the HQ Plus indicates the status of the serial ports of the device, and the number of active ST Plus connections.
The number of active connections has a binary representation. When there are no active connections, the connection LEDs light and unlight in sequence, creating a “bit walk”. When connections exist, the number of connections is represented by the sum of the values in each box above. For example, if the “64”, “4”, and “1” LEDs were lit, the number of active connections would be 69.

The HQ Remote Console and HQ Remote Poller provide the capability to locate a parallel "HQ site" which can be readily re-located. The HQ Remote Console and the HQ Remote Poller can be deployed as standalone devices, at the same or at separate sites. Enabling and disabling of the remote devices is controlled from the main HQ Plus through the HQ Basic software control to allow or disallow remote console and remote poller functions accesses.
Figure 7: HQ Remote Console: DB-9F serial connector

The HQ Remote Console provides an output of the "current connection status" of the system, via the serial port on the HQ Remote Console device.
The data output is a "duplicate" of the output from the main HQ Plus, which may be located elsewhere on the WAN, LAN, or Internet.
The PC that is connected to the serial port of the HQ Remote Console runs the HQ Basic utility. The same control capabilities exist at the HQ Remote Console site at the main HQ Plus.
The HQ Remote Console can be located anywhere where there is an Internet communication capability available. Only one HQ Remote Console may be associated with any one HQ Plus, and the site LAN requirements are the same as for an ST Plus installation.
The HQ Remote Console communicates with the main HQ Plus in a way similar to that used by a standard ST Plus.
Figure 8: HQ Remote Poller: DB-25F serial connector

The HQ Remote Poller hardware provides the capability to use polling software applications to poll and communicate with the ST Plus devices that are "connected" to the main HQ Plus.
Only one HQ Remote Poller may be associated with any one HQ Plus.
The site LAN requirements are the same as for an ST Plus installation.

While not essential to the main task of polling over IP, the following components supplement the basic HQ-ST Link and and assist installation or are required for device configuration .
This system management utility, supplied with HQ Plus hardware, provides configuration interfaces for HQ Plus and ST Plus devices, and presents a tabular view of the state of all ST Plus connections current on a given HQ Plus. It also provides rudimentary connection logging and debugging information, and a live “chat” interface for HQ-ST system administrators to communicate with installers in the field.
HQ Basic resides on the host PC, which is connected to the Console port of the HQ Plus. It is loaded from the LAVA Installation CD.
See “HQ Basic: Operation” on page 19.
This application, supplied with ST Plus hardware, provides a configuration interface for ST Plus devices, and a live “chat” interface for installers to communicate with a head office.
This utility resides on a PC host and is used via the serial port of the ST Plus. It is loaded from the LAVA Installation CD.
Connect the serial port of the host PC to the serial port of the ST Plus, start the utility, select the COM port, then cycle the power to the ST Plus. The ST Plus Configuration Console communicates with and is ready to configure the ST Plus.
See “ST Configuration Console: Operation” on page 16.
This device management utility is used to locate, display, and configure the current network settings of the LAVA HQ Plus and ST Plus devices, and to indicate the network settings of the Host PC that is connected to the LAN. The Host PC network settings can be used to assist in selecting the static IP settings that may be required by the HQ Plus and ST Plus (if DHCP is not available) for operation on the LAN.
This utility operates on a LAN only. The LAN must not block UDP broadcast packets. Network security programs/ firewall may need to be disabled or edited to allow the UDP broadcast packets on the LAN.
The Host PC may be connected directly to the HQ Plus or ST Plus via a standard Ethernet cross-over cable, in order to bypass using the LAN environment.
The utility is downloaded from www.lavalink.com

To set up an HQ Plus for polling you will need:
HQ Plus devices communicate over Ethernet LAN/WAN facilities. The devices must be configured with the appropriate IP addresses and port numbers for the specific LAN onto which these devices are to be connected.
The installer must know the correct network parameters to configure HQ Plus devices for operation.
The WAN/Internet IP address must be a known STATIC IP address (or an assigned DNS name). Use Internet Explorer to access www.whatismyip.com to verify the address. Also verify that this is so by accessing the setup parameters of the gateway/router that is to be used to provide the access to the Internet for the LAN.








See “Test that the HQ Site is Properly Set Up and Working: HQ Plus Installed” on page 26.
See “Test the End-to-End HQ-ST Link Communications: HQ and ST Installed” on page 27.
See “Troubleshooting” on page 28.
METHOD#2: Headquarters Installation using Ether Link Manager and the Web Page

The WAN/Internet IP address must be a known STATIC IP address (or an assigned DNS name). Use Internet Explorer to access www.whatismyip.com to verify the address. Also verify that this is so by accessing the setup parameters of the gateway/router that is to be used to provide the access to the Internet for the LAN.
Use the LAVA Ether Link Manager utility (See “LAVA Ether Link Manager Utility” on page 5.) to configure the LAN NETWORK settings of the HQ Plus, then (on knowing the IP address of the HQ Plus) use the web page (See “Web Page Interface on HQ Plus and ST Plus” on page 32.) to configure any parameters on the HQ Plus.
The default ports are 4098 and 4099, (that is, a base port and a base+1 port). Use the web page interface to the HQ Plus to configure the base port number of the HQ Plus. The second port number is computed automatically based on this first value.
Port Forward the HQ Plus IP address base and base+1 ports, through the gateway to allow access to the HQ Plus's IP address:ports from the Internet. Use the information provided on www.portforward.com to accomplish the "port forwarding" procedure on your particular installed gateway/router.
Configure the serial port of the HQ Plus to match the requirements of the equipment that is to be connected to the serial port of the HQ Plus.
SPECIAL NOTE: Some application software programs that communicate with a serial modem expect that the "modem" is installed as a TAPI device under Windows. In this case follow the procedure to install the HQ Plus as a Generic 56K Modem on a selected Com:n port, set the baud rate as required for the equipment, and set the option to operate WITHOUT waiting for Dial Tone. Once the device is "installed", re-boot the PC then do a test by querying the modem to verify the correctness of the "modem installation". See “Installing the HQ Plus on the PC as a (TAPI) Modem” on page 31.
Some application software programs only expect that an external modem is connected to a serial port on the PC. In this case connect the HQ Plus to the appropriate Com:n serial port. The application program will send AT commands through the serial (com:n) port to the HQ Plus.
Information to be noted: Keep this information on hand for reference when setting up the ST Plus devices, and for test/troubleshooting purposes.
Internet (WAN) IP address of the HQ site. This is the "call home" IP address that will be entered into all ST Plus devices that are to communicate with this HQ Plus on IP(WAN):port/s.
Base and Base+1 Ports assigned. The Base Port number will be entered into all ST Plus devices, as part of the unique "call home" IP address information, of the HQ Plus. Note several HQ Plus devices can be located at the site, but each HQ Plus will be uniquely identified by its assigned Base Port number.
See “Test that the HQ Site is Properly Set Up and Working: HQ Plus Installed” on page 26.
See “Test the End-to-End HQ-ST Link Communications: HQ and ST Installed” on page 27.

See “Troubleshooting” on page 28.

To set up an ST Plus for polling you will need:
ST Plus devices communicate over Ethernet LAN/WAN facilities. The devices must be configured with the appropriate IP addresses and port numbers for the specific LAN onto which these devices are to be connected.
The installer must know the correct network parameters to configure ST Plus devices for operation.
In general the ST Plus is very easy to install on a LAN that has DHCP support. If the LAN does not provide DHCP, then determine or obtain the set of static IP addresses that are to be used by the ST Plus on the LAN:
Make a note of these IP addresses. They will be entered as part of the network settings of the ST Plus.
The essential operating parameters will typically be pre-configured before installation at the remote location.
Optional parameters include:






Operating modes are as follows:
STOP. In this mode the ST Plus is not communicating to an HQ Plus. The ST Plus can be fully re-configured using the ST Config utility or the web page interface, and LAVA Ether Link Manager.

RUN. Enter this mode after the ST Plus is set up, to test if it can open a connection to the designated "call home" IP:port of an HQ Plus. In this mode the ST Plus will connect to the HQ Plus, and remain connected and fully operating, until the ST Plus is reset or power cycled . After a reset or power cycling, the ST Plus will revert to STOP mode.
Run mode is typically used for testing the setup configuration or re-configuration, prior to placing the ST Plus into fully operational mode.
Access the web page of the ST Plus to check its connection status.
When the ST Plus is in Run mode the LAVA Ether Link Manager will not "locate/find" the ST Plus.
ACTIVATED. This mode is the normal operating mode for the ST Plus. The device will always attempt to re-connect to the HQ Plus's IP:port as designated by the “Home IP” entry of the ST Plus.
Select this mode only if all ST parameters are set, and correct.
Access the web page of the ST Plus to check its connection status.
When the ST Plus is in Activated mode, the LAVA Ether Link Manager will not "locate/find" the device. In this case, use the ST Configuration Console to make any changes. The user may also make changes to the ST Plus's configuration by using the HQ Basic software utility running at the head office site, or by using an HQ Remote Console device at any location.
See “Test the End-to-End HQ-ST Link Communications: HQ and ST Installed” on page 27.
See “Troubleshooting” on page 28.

The ST Configuration Console provides a Windows-based interface for users to configure the network and serial port settings of an ST Plus device. These settings are required for the operation of the ST Plus in an HQ-ST Link.
It also provides an interface for supplying store-specific information for storing in an ST Plus. These details are not used for connectivity, but may be used as contact information or for store identification from the head office.
The ST Configuration Console software runs on a host PC that has a serial port connected to the serial port of the ST Plus device, using a straight-through serial cable. The ST Plus end of the cable will need a DB-25 male connector; the host PC end of the cable will probably need a DB-9 female connector (depending on the serial port connector being used on the host PC).
To establish a connection between the ST Plus and the ST Plus Configuration Console, follow the following steps:









HQ Basic provides a Windows-based interface for users to configure the network and serial port settings of an HQ Plus device or ST Plus device. These settings are required for the operation of the HQ Plus and ST Plus in an HQ-ST Link.
It also provides an interface for supplying and displaying store-specific information in an ST Plus. These details are not used for connectivity, but may be used as contact information or for store identification from the head office.
The HQ Basic software runs on a host PC that has a serial port connected to the “Console” port of the HQ Plus, using a straight-through serial cable. The HQ Plus end of the cable will need a DB-9 male connector; the host PC end of the cable will probably need a DB-9 female connector (depending on the serial port connector being used on the host PC).
To establish a connection between the HQ Plus and the HQ Basic software, follow the following steps:

The HQ Basic connections table (shown above) reserves two connection slots for the console and control ports of the HQ Plus. These ports can be used by the HQ Remote Poller and HQ Remote Console to connect to the HQ Plus.
The HQ Basic connections table also provides access to a variety of debugging log filters, shown on the right.
Double-clicking on an ST Plus entry in the connection table opens screens for that ST Plus, and makes it possible to make and upload changes to a remote ST Plus device. Similarly, double-clicking on the Console port or Control port entry in the connection table allows configuration of these ports.








This installation checklist will assist installers of ST Plus devices when planning a store installation of an HQ-ST Link. It exists as a PDF on the Installation CD, from which it can be printed in any desired quantity.
LAVA COMPUTER MFG. INC.
2 VULCAN STREET, TORONTO, ONTARIO M9W 1L2 TEL: (416) 674-5942 FAX: (416) 674-8262 www.lavalink.com
Rev. A00
LAVA recommends completing this worksheet before attempting to install an ST PLUS to ensure that all necessary configuration parameters are known.
Store name:
Store no.:
Address:
Voice telephone no.:
City:
State/province:
Zip/postal code:
Country:
ST Plus unit no. (if site has more than one):
Default gateway:
DNS server IP:
HTTP port:
Assigned local TCP port:
Device name:
Home IP/port:
Device telephone no.:
Device DNS:
Identification key:
If not using DHCP, supply the following:
IP address:
Subnet mask:
Default gateway:
DNS server IP:
HTTP port:

LAVA recommends completing this worksheet before attempting to install an ST PLUS to ensure that all necessary configuration parameters are known.
ST PLUS DEVICE SERIAL INFORMATION (match serial port settings to ECR)
o 9600 o 4800 o 2400 o 1200
o 300 o 110
ECR CONNECTOR AND SERIAL INFORMATION (match serial port settings to ST Plus unit)
o 9600 o 4800 o 2400 o 1200
o 300 o 110


Devices on the LAN
Alternative method to check if the PC/laptop is operating using STATIC IP settings or DHCP

Determine if the selected HQ Plus site has a STATIC WAN IP address or a registered DNS name, that can be used by an Internet user to access devices (HQ Pluses) that are located behind the gateway/router at the HQ Plus site.


Installed

The ST Plus device cannot connect to the HQ Plus.
At the store location: Ensure power is supplied to the ST Plus.
Check that the LAN to which the ST Plus is connected has access to the Internet.
Check that the ST Plus is connected to the store’s LAN with a Cat 5 UTP cable, with an RJ-45 connector.
Check that the ST Plus has been given the IP address and port of the HQ Plus to which you want to connect.
Check that DHCP is enabled on the store’s LAN, or if not, that the ST Plus has been supplied with a unique IP address, appropriate net mask, and gateway address.
Ensure that the ST Plus has an Identification Code that matches that of the HQ Plus to which you want to connect.
At the head office location: Ensure power is supplied to the HQ Plus.
Check that the LAN to which the HQ Plus is connected has access to the Internet.
Check that the HQ Plus is connected to the LAN with a Cat 5 UTP cable, with an RJ-45 connector.
Check that the HQ Plus has been given the IP address of the gateway/router it will use for Internet access.
Check that the two ports that the HQ Plus will use for communication to the ST Plus have been mapped on the gateway/router of the head office.
Ensure that the HQ Plus has a static IP address.
Ensure that the HQ Plus has an Identification Code that matches that of the ST Plus that will be contacting it.
The ST Plus and the HQ Plus “see” each other, but polling does not work.
At the store location: Ensure that power is supplied to the ECR or POS station that you want to poll.
Ensure that the ECR or POS station’s serial port is connected to the ST Plus with a straight-through serial cable.
Ensure that the ST Plus has been assigned a “telephone number” that polling software at the head office can use to poll, as if it were dialing a modem.
Ensure that all parameters of the serial port on the ECR or POS station are configured for polling according to the manufacturer’s directions (baud rate, parity, stop bits, flow control, etc.).
Ensure that all parameters of the serial port on the ST Plus are configured to match those of the ECR or POS station (baud rate, parity, stop bits, flow control, etc.)
At the head office location: Ensure that the polling software is properly installed on the host PC.
Ensure that the polling software is compatible with the ECR or POS station that you wish to poll.
Ensure that the polling software is configured to use a serial port with the parameters to which the host PC’s port has been set.
Ensure that the polling software is configured with the “telephone number” of the ECR or POS station that you want to poll.
Ensure that the polling software is configured to use the serial port on the host PC that is connected to the HQ Plus.
Ensure that the correct serial port of the host PC is connected to the “Modem” port of the HQ Plus using a straight-through serial cable.
Ensure that all parameters of the serial port on the host PC are configured for polling according to the manufacturer’s directions (baud rate, parity, stop bits, flow control, etc.).
Ensure that the correct serial port of the host PC is connected to the “Modem” port of the HQ Plus.

At both store and head office locations:
HQ Basic does not show active HQ Plus to ST Plus connections
At the head office: Ensure that HQ Basic is properly installed on its host PC. This PC might or might not be the same PC that is hosting the polling software, but if these two applications are sharing one host PC then ensure that the joint host PC has two distinct serial ports, one for each application to use.
Ensure that HQ Basic is configured to address the same serial port that is connected to the “Console” port of the HQ Plus.
Ensure that the serial port that HQ Basic is addressing is connected to the “Console” port of the HQ Plus using a straight-through serial cable.
HQ Remote Console and HQ Remote Poller initial setup
At the head office and store locations:
Ensure that a working HQ-ST Link setup is already in place before attempting to add an HQ Remote Console or HQ Remote Poller to the mix. Polling software at the head office should be able to successfully poll an ECR or POS station at a remote store location, to verify connectivity.
HQ Remote Console does not show ST Plus connections on the HQ Plus
At the head office location: Ensure that HQ Basic running at the head office has been configured to permit remote accesses.
At the location of the HQ Remote Console:
Ensure that HQ Basic is properly installed on the host PC at the remote location. This PC might or might not be the same PC that is hosting an HQ Remote Poller, but if these two devices are sharing one host PC then that PC needs two distinct serial ports, one for each device to use.
Ensure that HQ Basic at the remote location is configured to address the same serial port that is connected to the serial port of the HQ Remote Console.
Ensure that the serial port that HQ Basic is addressing is connected to the serial port of the HQ Remote Console using a straight-through serial cable.
Ensure power is supplied to the HQ Remote Console.
Check that the LAN to which the HQ Remote Console is connected has access to the Internet.
Check that the HQ Remote Console is connected to the LAN with a Cat 5 UTP cable, with an RJ-45 connector.
HQ Remote Poller does not poll the ECR/POS station
At the head office location: Ensure that HQ Basic running at the head office has been configured to permit remote accesses.
At the location of the HQ Remote Poller:
Ensure that the polling software is properly installed on the host PC at the remote location. This PC might or might not be the same PC that is hosting an HQ Remote Console, but if these two devices are sharing one host PC then that PC needs two distinct serial ports, one for each device to use.
Ensure that the polling software at the remote location is configured to address the same serial port that is connected to the serial port of the ECR/POS station.
Ensure that the serial port that the polling software is addressing is connected to the serial port of the HQ Remote Poller using a straight-through serial cable.
Ensure power is supplied to the HQ Remote Poller.
Check that the LAN to which the HQ Remote Poller is connected has access to the Internet.
Check that the HQ Remote Poller is connected to the LAN with a Cat 5 UTP cable, with an RJ-45 connector.
NOTE: An operating HQ Remote Poller setup is in fact an exercise of most aspects of the HQ-ST Link system. This is because a poll directed from an HQ Remote Poller must successfully pass from the location of the HQ Remote Poller, over the Internet to the HQ Plus running at the head office, out to the Internet again and over to the ST Plus at its store location, through to the ECR or POS station being polled, then back to the ST Plus again and out to the Internet again and over to the HQ Plus, then out to the Internet yet again and back to the HQ Remote Poller, then finally to the remote host PC . This will only happen when all aspects of the full HQ-ST system are working (with the exception of the HQ Remote Console).

In the event that the HQ Plus or ST Plus must be reset to the factory default settings, use the following procedure:

This completes the installation of the "modem". This "modem" will be selected for use when setting up the application polling software in the operating parameters.

Use Windows Internet Explorer (or similar web browser) to access the HQ Plus or ST Plus to configure the device for operation.
To use the web page, the user must know the IP address (ie http://192.168.0.35) of the HQ Plus or ST Plus, and the Host PC must be on the same LAN IP segment as the HQ Plus or ST Plus.
Setup of the HQ Plus is performed using the web page interface.
If an ST Plus is operating in "activated" mode, only the web page status page will be available - no changes can be made via the web page.
Enter the Windows command line utility (Start>Run>cmd>).
Enter the command “ping 192.168.0.35” to test if the Host PC can communicate with the device at IP address 192.168.0.35.
The ping test must come back with a positive reply, to indicate that the PC can communicate with the device at the specified IP address.
Enter the Windows command line utility (Start>Run>cmd>).
Enter the command “ipconfig” to get the immediate IP settings of the Host PC.
Enter the command “ipconfig /all” to get more information about the LAN settings on which the Host PC is communicating, including whether the PC is operating under LAN DHCP or static IP address parameters.
This utility is available under Windows (Start>Programs>Accessories>Communications>HyperTerminal). Use this utility to test the serial I/O communications, when using Com:n selections. Note: may not be available on all Windows systems.
Use this utility to test Ethernet TCP/IP communications to an IP:Port on the LAN or over Internet, when using the WINSOCK selection.
This has similar utility to the HyperTerminal WINSOCK utility. Note: may not be available on all Windows systems.
Enter the Windows Command Line utility (Start>Run>cmd>).
Enter the command “telnet 67.123.45.127 4098” to establish a TCP/IP connection to the device at IP address 67.123.45.127 with port 4098. A message will be returned if the connection cannot be established.
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| The ST Plus device cannot connect to the HQ Plus. | p.30 | ||
| At the store location: | Ensure power is supplied to the ST Plus. | p.30 | |
| At the store location: | Check that the LAN to which the ST Plus is connected has access to the Internet. | p.30 | |
| At the store location: | Check that the ST Plus is connected to the store’s LAN with a Cat 5 UTP cable, with an RJ-45 connector. | p.30 | |
| At the store location: | Check that the ST Plus has been given the IP address and port of the HQ Plus to which you want to connect. | p.30 | |
| At the store location: | Check that DHCP is enabled on the store’s LAN, or if not, that the ST Plus has been supplied with a unique IP address, appropriate net mask, and gateway address. | p.30 | |
| At the store location: | Ensure that the ST Plus has an Identification Code that matches that of the HQ Plus to which you want to connect. | p.30 | |
| At the head office location: | Ensure power is supplied to the HQ Plus. | p.30 | |
| At the head office location: | Check that the LAN to which the HQ Plus is connected has access to the Internet. | p.30 | |
| At the head office location: | Check that the HQ Plus is connected to the LAN with a Cat 5 UTP cable, with an RJ-45 connector. | p.30 | |
| At the head office location: | Check that the HQ Plus has been given the IP address of the gateway/router it will use for Internet access. | p.30 | |
| At the head office location: | Check that the two ports that the HQ Plus will use for communication to the ST Plus have been mapped on the gateway/router of the head office. | p.30 | |
| At the head office location: | Ensure that the HQ Plus has a static IP address. | p.30 | |
| At the head office location: | Ensure that the HQ Plus has an Identification Code that matches that of the ST Plus that will be contacting it. | p.30 | |
| The ST Plus and the HQ Plus “see” each other, but polling does not work. | p.30 | ||
| At the store location: | Ensure that power is supplied to the ECR or POS station that you want to poll. | p.30 | |
| At the store location: | Ensure that the ECR or POS station’s serial port is connected to the ST Plus with a straight-through serial cable. | p.30 | |
| At the store location: | Ensure that the ST Plus has been assigned a “telephone number” that polling software at the head office can use to poll, as if it were dialing a modem. | p.30 | |
| At the store location: | Ensure that all parameters of the serial port on the ECR or POS station are configured for polling according to the manufacturer’s directions (baud rate, parity, stop bits, flow control, etc.). | p.30 | |
| At the head office location: | Ensure that the polling software is properly installed on the host PC. | p.30 | |
| At the head office location: | Ensure that the polling software is compatible with the ECR or POS station that you wish to poll. | p.30 | |
| At the head office location: | Ensure that the polling software is configured to use a serial port with the parameters to which the host PC’s port has been set. | p.30 | |
| At the head office location: | Ensure that the correct serial port of the host PC is connected to the “Modem” port of the HQ Plus using a straight-through serial cable. | p.30 | |
| At the head office location: | Ensure that all parameters of the serial port on the host PC are configured for polling according to the manufacturer’s directions (baud rate, parity, stop bits, flow control, etc.). | p.30 | |
| At both store and head office locations: | IDEALLY, the serial ports and software along the entire polling path from ECR or POS station to the head office polling software should be set the same. These include: • any software in the ECR or POS station that permits polling access • the ECR or POS station’s polling serial port • the ST Plus’s serial port • the “Modem” port on the HQ Plus • the serial port on the host PC that is connected to the “Modem” port on the HQ Plus • the polling software on the host PC at the head office | p.31 | |
| HQ Basic does not show active HQ Plus to ST Plus connections | p.31 | ||
| At the head office: | Ensure that HQ Basic is properly installed on its host PC. This PC might or might not be the same PC that is hosting the polling software, but if these two applications are sharing one host PC then ensure that the joint host PC has two distinct serial ports, one for each application to use. | p.31 | |
| At the head office: | Ensure that HQ Basic is configured to address the same serial port that is connected to the “Console” port of the HQ Plus. | p.31 | |
| At the head office: | Ensure that the serial port that HQ Basic is addressing is connected to the “Console” port of the HQ Plus using a straight-through serial cable. | p.31 | |
| HQ Remote Console and HQ Remote Poller initial setup | p.31 | ||
| At the head office and store locations: | Ensure that a working HQ-ST Link setup is already in place before attempting to add an HQ Remote Console or HQ Remote Poller to the mix. Polling software at the head office should be able to successfully poll an ECR or POS station at a remote store location, to verify connectivity. | p.31 | |
| HQ Remote Console does not show ST Plus connections on the HQ Plus | p.31 | ||
| At the head office location: | Ensure that HQ Basic running at the head office has been configured to permit remote accesses. | p.31 | |
| At the location of the HQ Remote Console: | Ensure that HQ Basic is properly installed on the host PC at the remote location. This PC might or might not be the same PC that is hosting an HQ Remote Poller, but if these two devices are sharing one host PC then that PC needs two distinct serial ports, one for each device to use. | p.31 | |
| At the location of the HQ Remote Console: | Ensure that HQ Basic at the remote location is configured to address the same serial port that is connected to the serial port of the HQ Remote Console. | p.31 | |
| At the location of the HQ Remote Console: | Ensure that the serial port that HQ Basic is addressing is connected to the serial port of the HQ Remote Console using a straight-through serial cable. | p.31 | |
| At the location of the HQ Remote Console: | Ensure power is supplied to the HQ Remote Console. | p.31 | |
| At the location of the HQ Remote Console: | Check that the LAN to which the HQ Remote Console is connected has access to the Internet. | p.31 | |
| At the location of the HQ Remote Console: | Check that the HQ Remote Console is connected to the LAN with a Cat 5 UTP cable, with an RJ-45 connector. | p.31 | |
| HQ Remote Poller does not poll the ECR/POS station | p.31 | ||
| At the location of the HQ Remote Poller: | Ensure that the polling software is properly installed on the host PC at the remote location. This PC might or might not be the same PC that is hosting an HQ Remote Console, but if these two devices are sharing one host PC then that PC needs two distinct serial ports, one for each device to use. | p.31 | |
| At the location of the HQ Remote Poller: | Ensure that the polling software at the remote location is configured to address the same serial port that is connected to the serial port of the ECR/POS station. | p.31 | |
| At the location of the HQ Remote Poller: | Ensure that the serial port that the polling software is addressing is connected to the serial port of the HQ Remote Poller using a straight-through serial cable. | p.31 | |
| At the location of the HQ Remote Poller: | Ensure power is supplied to the HQ Remote Poller. | p.31 | |
| At the location of the HQ Remote Poller: | Check that the LAN to which the HQ Remote Poller is connected has access to the Internet. | p.31 | |
| At the location of the HQ Remote Poller: | Check that the HQ Remote Poller is connected to the LAN with a Cat 5 UTP cable, with an RJ-45 connector. | p.31 | |
| NOTE: An operating HQ Remote Poller setup is in fact an exercise of most aspects of the HQ-ST Link system. This is because a poll directed from an HQ Remote Poller must successfully pass from the location of the HQ Remote Poller, over the Internet to the HQ Plus running at the head office, out to the Internet again and over to the ST Plus at its store location, through to the ECR or POS station being polled, then back to the ST Plus again and out to the Internet again and over to the HQ Plus, then out to the Internet yet again and back to the HQ Remote Poller, then finally to the remote host PC . This will only happen when all aspects of the full HQ-ST system are working (with the exception of the HQ Remote Console). | p.31 |