Driver Installation
Screw for attaching card bracket to PC casing
Serial Port · Parallel Port · PCI Slot

order to complete the installation of the SP-PCI card.Any Plug and Play devices attached to the SP-PCI will now also be detected and installed.Windows XP may display a message to the effect that the drivers are not digitally signed.This warning can be ignored.
6. To view how Windows has installed the SP-PCI,open Windows' Device Manager.Please note that the SP-PCI will appear in Device Manager under two separate entries.The serial port will appear both under the Multifunction Adapters tree and under the Ports tree, while the Parallel port will appear under Ports only (see example below).Please use the appropriate listings if you wish to customize any of the SP-PCI card’s settings.Please note that changes to default settings may be required by users connecting the SP-PCI card to a non-printer peripheral (see reverse).Users connecting a printer should use default settings.


to the SP-PCI's parallel port
In Windows 95/98/ME (not Windows 2000/XP) some parallel port devices require parallel ports that use standard (legacy) ISA LPT addresses (0278h or 0378h).Because the SP-PCI card is a fully compliant PCI device,its default address (Input/Output Range) is beyond the standard range of ISA I/O addresses.In order to connect such a peripheral to the SP-PCI card,the I/O address range of the card must therefore be changed manually.This section describes how this is done.



0278 – 027F 0378 – 037F 0238 – 023F 02B8 – 02BF

port (Windows 95/98/Me only)
Unless you already have more than 4 Com Ports installed in your PC, Windows will by default configure the SP-PCI as Com 5.If you wish to change this assigned Com number (e.g.reassign Com 5 to be Com 3), please use the Lava Com Port Redirect Utility included in the “Utils\Redirect“ subdirectory of your Installation Diskette.Such a reassignment may be necessary because some communications applications programs do not recognize port designations beyond Com 4.The Com Port Redirect utility will allow you to change the Com numbering of your ports .
without changing I/O address resources
To install the Port Redirect Utility on your hard drive,insert the Installation Diskette into your floppy drive,click Start,Run and type A:\Utils\Redirect\Setup.
port (Windows 2000/XP only)
In Windows 2000,Com port numbering can be changed by double- clicking the serial port entry displayed in Windows' Device Manager (as described earlier).Go to Port Settings | Advanced,and choose Com Port #.


NOTE:The default input/output range for the SP-PCI card works with Zip™ drives using new Iomegaware™ software.The instructions "Connecting a non-printer device" given above apply to Zip™ drive users using old versions of Iomegaware™.For best results with Windows 2000 and XP,we recommend downloading the latest "Iomegaware" from Iomega.Additional instructions on optimizing Zip Drive performance with the SP-PCI can be found at www.lavalink.com
A. This documentation describes installing the SP-PCI on a
Windows95/98/Me/2000/XP PC.Instructions and software for DOS, Windows 3.x,and Windows NT 4.0 may be found in the NT4.0 subdirectory of the SP-PCI card Installation diskette.Instructions for Linux installation are available at www.lavalink.com
B. Because the SP-PCI card uses PCI (not ISA) I/O address ranges,it will never be seen by your BIOS at boot-up as a standard port even if the address has been changed in Windows using the above procedure. This is normal,and does not indicate a fault in your SP-PCI card.
C. The parallel port of the SP-PCI card will not work at address 0278h or 0378h if it is installed in a PCI slot that is behind a PCI-to-PCI bridge. If you have trouble installing the SP-PCI card,try seating it in a different slot.
D. In standard installations of Windows 2000/XP,the I/O address cannot
be changed to a legacy address.
E. Some devices (like external CD writers) default to "word mode" (ie: 16-bit data transfer) for fastest performance.Such devices need to operate in "byte mode" (8-bit data transfer) to work with the SP-PCI. Look in your device software for a "byte mode" setting,and enable it.

Tel:+416 674-5942 Fax:+ 416 674-8262
E-mail:[email protected] Internet:www.lavalink.com
Lava Computer MFG Inc.
This device complies with part 15 of the FCC Rules.Operation is subject to the following conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received,including interference
that may cause undesired operation. Lava Computer MFG Inc.908 Niagara Falls Blvd.#629.North Tonawanda NY 14120-2060
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.