Remote Power -Off Devic e AP9830 Ins talla tion an d Quick Star t.
Remote Po wer-Off Devic e — Installa tion and Q uick Start Conte nts Features and Requirements 1 Feature s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Hardwa re Re quire ments . . . . . . . . . . . . . . . . . . . . 2 Safety Inf ormation 3 Avoid H azardo us Confi guration s .
ii Remote Po wer-Off Devic e — Installation a nd Quick Start Contents Set up t he Rem ote P ower-Of f Devic e . . . . . . . . . . 14 Remot e switch: r equirement s and pin as signment 16 Pin locati .
1 Featur es and Re quir ements Featur es The APC ® Remote Pow er-Off Device (RPO), AP9830, enables you to tu rn off the output pow er of an APC uninterruptible pow er supply (UPS) imm ediately by a remote swit ch. For exam ple: • If the UPS itself is n ot readily accessible, place the RPO in a convenien t location.
2 Remote Po wer-Of f Devic e — Installation a nd Quick St art H a rdw a re R e q u i rem e n t s The Remote Power- Off Device requires the f ollowi ng: • A Sm art-UPS ® or Matrix-UPS ™ . • A sw itch (SEL V or Class 2 circuit). • A cable to connect the rem ote sw itch to the R emote Power-Off Device.
3 Safety Information Avoid Hazar dous Configurations Example of the potentia l hazard 1. An adm inis trator uses th e remote sw i tch conn ected to the Remote Pow er-Off Device to turn off the output pow er from a UPS, but the UPS continu es to receive utilit y pow e r .
4 Remote Po wer-Of f Devic e — Installation a nd Quick St art Eliminate t he Hazard Use a n Emergency Power Off system Matrix-UPS m odels and man y S mart- UPS models have an integrated EPO system th at allow s connected equipmen t to be deenergized immediately f rom a rem ote location with out the UPS switch ing to battery operation.
Remote Power-Off Device — Installation a nd Quick St art 5 Safe ty Inf orma tio n: E limi nat e t he H azar d Block a ccess to acces sory devic es The Remote Power-Off Device can provide a usef ul a.
6 Remote Po wer-Of f Devic e — Installation a nd Quick St art Contact Closur e Setup with Multiple UPSs T o elimin ate t he ne ed fo r multip le conta ct cl osu res a t the remo te s w itch , do one of th e foll owing: • Use an applied voltage sw itch.
7 V erify C ontents of the Shipment Unpack and Inspec t the RPO Pa ckage Please r ecycle Receiving inspecti on Inspect the package and conten ts for shipping damag e, and make su re that all parts w ere sent.
8 Remote Po wer-Of f Devic e — Installation a nd Quick St art Verify Contents o f the Ship ment: Unpack and Inspect the RPO P ackage • Remote Pow er-Off Device • Keystone jack (750-0023) • A strip of hook-an d-loop fastener (not sh own here) for optional mount ing of th e Rem ote Power-Off Dev ice.
9 Components of the RPO Side Views View fr om the server sid e of the RPO View fr om the UPS side of th e RPO DB9 female port to connect to server or accessories RJ-1 1 port: RPO/Cascade In .
10 Remote Power- Off Device — Insta llation and Q uick Start To p V i e w Pow e r-O ff /T e st L ED Labels that identif y component s on the sides of the RPO .
11 Configur ation and Setup Overvi ew T o configure and set up th e Rem ote Power-Off Dev ice: 1. C onfig ure the RPO to oper ate in T est ( Disab led ) po w er - off mode by settin g DIP sw itch #3 to the up position. 2. Connect the RPO. 3. T est the RPO w hile leavin g DIP sw itch #3 in the u p position.
12 Remote Power- Off Device — Insta llation and Q uick Start Config ur e the R emote Power -Off Device Ty p e s o f r e m o t e switches supported The RPO supports two ty pes of remote sw it ches: • A contact closure sw itch toggles betw een an open and closed circuit.
Remote Power-Off Device — Installation a nd Quick St art 13 Configura tion and Setup: Confi gure the Remote Po wer -Off Device Power -off m ode: DIP switch #3. In either power-off mode, the Rem ote Power-Off Dev ice LED illum in ates wh en the device is connected and config ured properly and the rem ote swit ch is being asserted.
14 Remote Power- Off Device — Insta llation and Q uick Start Set up t he Remote Power-Off De vice Connect s ingle and multi ple RPOs Y ou can connect one R em ote Power-O ff Device to one rem ote swit ch to control one UPS, or you can connect m u ltiple Remote Pow er-Off Devices to one rem ote sw itch to control mult iple UPSs sim ultaneous ly .
Remote Power-Off Device — Installation a nd Quick St art 15 Configura tion an d Setup: Set u p the Remote Po wer -Off Device Note In the follow ing set-u p diagram, note th at the RJ-1 1 cable connects to the m iddle port, labeled RPO / Cascade In .
16 Remote Power- Off Device — Insta llation and Q uick Start Configu ration a nd Setup: Set up the Remote P ower-Off Device Remote s witch: re qu i re m e n ts and pin assign ment Pin locations for .
Remote Power-Off Device — Installation a nd Quick St art 17 Configura tion an d Setup: Set u p the Remote Po wer -Off Device Connect th e switch cab le to the keystone jack 1. Strip the cable j acket (the outer ins ulation of th e cable) to expose 1 inch (25.
18 Remote Power- Off Device — Insta llation and Q uick Start Configu ration a nd Setup: Set up the Remote P ower-Off Device 5. Press each w ire in to its s lot on the clear plastic cap. Then inspect the cap to ensure that each w ire is in the correct slot and that the end of each w i re touches the back of th e slot.
Remote Power-Off Device — Installation a nd Quick St art 19 Configura tion an d Setup: Set u p the Remote Po wer -Off Device 7. Using slip- joint pliers, terminat e the w ires by pressing the plastic cap and keys tone jack together un til the cap snaps into place.
20 Remote Power- Off Device — Insta llation and Q uick Start How to T urn Off the Output of Multiple UPSs T o set up more than one APC UPS to turn off from on e remote swit ch, y ou mu st have one Remote Pow er-Off Device for each UPS.
Remote Power-Off Device — Installation a nd Quick St art 21 Configura tion and Setup: How to Turn Off th e Output of Mult iple UPSs Matrix-UPS ® in a cascad ing configuration Y ou can in clude only one APC Matrix-U PS in a cascading configuration , and you m u st place it at the end of the series of UPSs (UPS n in the exam ple setup).
22 Pr oduct Information Selecting and Or dering Components Remote switch specifi catio ns Cabl e re qu i re m e n ts Y ou can u se the tw o RJ-11 cables that cam e w ith the Rem ote Power-Off Device or use ex isting building cables.
Remote Power-Off Device — Installation a nd Quick St art 23 Pr oduct Spe cificatio ns Physical Dimensions (H × W × D) Unit Shippi ng 2.54 × 9. 53 × 6.0 5 cm (1.0 0 × 3.75× 2.3 8 in) 7.26 × 24 .13 × 16 .51 cm (2.86 × 9.5 0 × 6.50 in) W eight Unit Shippi ng 0.
24 Remote Power- Off Device — Insta llation and Q uick Start W arranty and Se rvice Limited warranty APC w arrants the Rem ote Pow er-Off Device to be free from defects in m aterials and w orkm ansh ip for a period of tw o y ears from the date of purchas e.
Remote Power-Off Device — Installation a nd Quick St art 25 Product In formation: Wa r rant y and Service warranty expired, y ou w ill be charged for repair o r replacement. 4. Pack the unit carefu lly . The warrant y does not cover damage su stained in tran sit.
26 Remote Power- Off Device — Insta llation and Q uick Start Life-Support Policy General poli cy Am erican Power Con version ( APC ) does not recomm end the use of any of its products in th e follow.
Radio Fr equency Interfer ence This product contains no clocks or oscillators and therefore does not cause interference..
*990-0197A* APC W orldwide Customer Support Cust omer supp ort for this or an y other APC produ ct is av ailable at no char ge in a ny of the following ways: • V i sit the APC W eb site to access documen ts in the APC Knowledge Bas e and to subm it custom er supp ort requ ests.
An important point after buying a device APC AP9830 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought APC AP9830 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data APC AP9830 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, APC AP9830 you will learn all the available features of the product, as well as information on its operation. The information that you get APC AP9830 will certainly help you make a decision on the purchase.
If you already are a holder of APC AP9830, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime APC AP9830.
However, one of the most important roles played by the user manual is to help in solving problems with APC AP9830. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device APC AP9830 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center