Kramer Electronics, Ltd.
Model:

Contents
1 Introduction 1 2 Getting Started 1 2.1 Getting Started 2 3 Overview 3 3.1 About the Power Connect Feature 3 3.2 Shielded Twisted Pair (STP)/Unshielded Twisted Pair (UTP) 3 3.3 Recommendations for Achieving the Best Performance 4 4 Your TP-114 1:4 XGA/HD DA/CAT 5 Transmitter 5 5 Configuring a TP-114 XGA/HD Line Transmitter – DA System 6 5.1 Wiring the CAT 5 LINE IN / LINE OUT RJ-45 Connectors 9 6 Technical Specifications 9
Figure 1: TP-114 1:4 XGA/HD DA/CAT 5 Transmitter 5 Figure 2: TP-114 1:4 XGA/HD DA/CAT 5 Transmitter (Underside Panel) 6 Figure 3: Configuring a TP-114 XGA/HD Line Transmitter – DA 8 Figure 4: CAT 5 PINOUT 9
Table 1: TP-114 1:4 XGA/HD DA/CAT 5 Transmitter Features 5 Table 2: TP-114 1:4 XGA/HD DA/CAT 5 Transmitter (Underside Panel) Features 6 Table 3: CAT 5 PINOUT 9 Table 4: Technical Specifications of the TP-114 (with 100m CAT 5 cable) 9

1 Introduction
Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and affordable solutions to the vast range of problems that confront the video, audio, presentation, and broadcasting professional on a daily basis. In recent years, we have redesigned and upgraded most of our line, making the best even better! Our 1,000-plus different models now appear in 11 groups1 that are clearly defined by function.
2 Download up-to-date Kramer user manuals from our Web site at http://www.kramerelectronics.com
3 The complete list of Kramer cables is on our Web site at http://www.kramerelectronics.com

2.1 Getting Started
This quick start chart summarizes the basic setup and operation steps.

Up to 4 of the line outputs to the line inputs (for example, on TP-120 XGA Line Receivers), via UTP cabling
Up to 4 of the line outputs to the line inputs (for example, on TP-120 XGA Line Receivers), via UTP cabling
L O 3 INE UT L O INE UT 4
You can change the polarity of decoding H and V Sync for video (see Figure 4 and Table 2):
You can change the polarity of decoding H and V Sync for video (see Figure 4 and Table 2):

3 Overview
Your Kramer TOOLS TP-114 1:4 XGA/HD DA/CAT 5 Transmitter is a high-performance distribution amplifier for computer graphics video or HDTV signals. It converts a computer graphics video or HDTV signal on a 15-pin HD connector to four identical twisted pair signals.
The Power Connect™ feature applies as long as the cable can carry power. This feature is available when using STP cable and the distance does not exceed 50m on standard CAT 5 cable. For longer distances, heavy gauge cable should be used4. For units which are connected via RJ-45 connectors, make sure that the shield of the STP cable is connected to the metal casing of the connectors on both ends of the cable. For units which are connected via terminal block connectors, the shield of the STP cable must be connected to a ground terminal on the units at both ends (use the ground terminal of the power supply connection if necessary).
For a CAT 5 cable exceeding a distance of 50m, separate power supplies should be connected to the transmitter and to the receiver simultaneously.
We recommend that you use Shielded Twisted Pair (STP) cable. There are different levels of STP cable available, and we advise you to use the best quality STP cable that you can afford. Our non-skew-free cable, Kramer BC-STP is intended for analog signals where skewing is not an issue. For
1 The terminology XGA is used throughout this manual, where this implies any RGBHV signal on an 15-pin HD connector
having a resolution from VGA up to UXGA
2 The TP-114 accepts high definition resolutions: 480p, 576p, 720p, 1080i, and 1080p
3 Note that the CAT 5 connectors exclude audio
4 CAT 5 cable is still suitable for the video/audio transmission, but not for feeding the power at these distances

cases where there is skewing, our UTP skew-free cable, Kramer BC-XTP, may be used. Bear in mind, though, that we advise using STP cables where possible, since the compliance to electromagnetic interference was tested using those cables.
Although Unshielded Twisted Pair (UTP) cable might be preferred for long range applications, the UTP cable should be installed far away from electric cables, motors and so on, which are prone to create electrical interference. However, since the use of UTP cable might cause inconformity to electromagnetic standards, Kramer does not commit to meeting the standard with UTP cable.

1 Available from Kramer Electronics on our Web site at http://www.kramerelectronics.com

4 Your TP-114 1:4 XGA/HD DA/CAT 5 Transmitter
Figure 1 and Table 1 define the TP-114 :

1 1 2 2 4 4 3 3 5
Table 1: TP-114 1:4 XGA/HD DA/CAT 5 Transmitter Features
1 Using a UTP CAT 5 cable with RJ-45 connectors at both ends (the PINOUT is defined in Table 3 and Figure 4)
2 Refer to the separate user manual: PT-110, PT-120, TP-120, WP-110, which can be downloaded from the Internet at:
http://www.kramerelectronics.com Also, see the example illustrated in Figure 3

Figure 2 and Table 2 define the TP-114 underside panel:

Table 2: TP-114 1:4 XGA/HD DA/CAT 5 Transmitter (Underside Panel) Features
You can use the TP-114 with four TP-120 units 3 to configure a 1:4 XGA/HD DA/CAT 5 Transmitter system. This will let you transmit a computer graphics/HD signal to four displays via long line CAT 5 UTP cabling. To connect the TP-114 to four TP-120 units, as the example in Figure 3 illustrates, do the following:
1 By default, both switches are set in the down position
3 Refer to the separate user manual: PT-110, PT-120, TP-120, WP-110, which can be downloaded from the Internet at:
http://www.kramerelectronics.com
2 Downgoing syncs

TP-120 OUT 2 connector to the LINE IN RJ-45 connector on the second
TP-120 OUT 3 connector to the LINE IN RJ-45 connector on the third
TP-120 OUT 4 connector to the LINE IN RJ-45 connector on the fourth
XGA/HD acceptor (for example, display 1) XGA OUT 15-pin HD connector of the second TP-120 unit to the
XGA/HD acceptor (for example, display 2) XGA OUT 15-pin HD connector of the third TP-120 unit to the
XGA/HD acceptor (for example, display 3) XGA OUT 15-pin HD connector of the fourth TP-120 unit to the
1 Via UTP cabling (with a range of more than 300ft (>100m)). For details of how to wire a CAT 5 LINE IN/LINE OUT
RJ-45 connector, see section 5.1
2 By default, both switches are set down (for negative V SYNC and H SYNC polarity)
3 Use a screwdriver to carefully rotate the trimmer, adjusting the appropriate level
4 By default, both switches are set down (to NORMAL) to retain the VS and HS polarity


L O 3 INE UT L O INE UT 4

5.1 Wiring the CAT 5 LINE IN / LINE OUT RJ-45 Connectors
Table 3 and Figure 4 define the UTP CAT 5 PINOUT, using a straight pin to pin cable with RJ-45 connectors:


Table 4 includes the technical specifications1 of the TP-114.
INPUT: 1 XGA on an 15-pin HD connector OUTPUTS: 1 XGA on an 15-pin HD connector, 4 RJ-45 OUT connectors MAX. OUTPUT LEVEL: 1.8Vpp (XGA), 1.6Vpp (CAT 5) MAX. RESOLUTION2: UXGA, 1080P DIFF. GAIN2: 0.03% (XGA), 7% (CAT 5) DIFF. PHASE2: 0.05° (XGA), 0.08° (CAT 5) K-FACTOR2:
1 Specifications are subject to change without notice
2 For the TP-114 Transmitter/ TP-120 Receiver pair
3 Sufficient for feeding two receivers via CAT 5

Kramer Electronics (hereafter ) warrants this product free from defects in material and workmanship under the following terms.
HOW LONG IS THE WARRANTY Labor and parts are warranted for seven years from the date of the first customer purchase.
Only the first purchase customer may enforce this warranty.
Except as below, this warranty covers all defects in material or workmanship in this product. The following are not covered by the warranty: 1. Any product which is not distributed by Kramer, or which is not purchased from an authorized Kramer dealer. If you are uncertain as to whether a dealer is authorized, please contact Kramer at one of the agents listed in the Web site www.kramerelectronics.com 2. Any product, on which the serial number has been defaced, modified or removed, or on which the WARRANTY VOID
TAMPERED sticker has been torn, 3. Damage, deterioration or malfunction resulting from: i) Accident, misuse, abuse, neglect, fire, water, lightning or other acts of nature ii) Product modification, or failure to follow instructions supplied with the product iii) Repair or attempted repair by anyone not authorized by Kramer iv) Any shipment of the product (claims must be presented to the carrier) v) Removal or installation of the product vi) Any other cause, which does not relate to a product defect vii) Cartons, equipment enclosures, cables or accessories used in conjunction with the product
IF reattached, removed or otherwise interfered with.
WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR
We will pay labor and material expenses for covered items. We will not pay for the following:
1. To obtain service on you product, you must take or ship it prepaid to any authorized Kramer service center. 2. Whenever warranty service is required, the original dated invoice (or a copy) must be presented as proof of warranty coverage, and should be included in any shipment of the product. Please also include in any mailing a contact name, company, address, and a description of the problem(s). 3. For the name of the nearest Kramer authorized service center, consult your authorized dealer.
All implied warranties, including warranties of merchantability and fitness for a particular purpose, are limited in duration to the length of this warranty.
The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option. Kramer shall not be liable for:
This warranty gives you specific legal rights, and you may also have other rights, which vary from place to place.
All products returned to Kramer for service must have prior approval. This may be obtained from your dealer. This equipment has been tested to determine compliance with the requirements of:
EN-50081: "Electromagnetic compatibility (EMC); generic emission standard. Residential, commercial and light industry" EN-50082: "Electromagnetic compatibility (EMC) generic immunity standard. Part 1: Residential, commercial and light industry environment". CFR-47: FCC* Rules and Regulations: Part 15: “Radio frequency devices Subpart B Unintentional radiators”
Part 1:
Servicing the machines can only be done by an authorized Kramer technician. Any user who makes changes or modifications to the unit without the expressed approval of the manufacturer will void user authority to operate the equipment. Use the supplied DC power supply to feed power to the machine. Please use recommended interconnection cables to connect the machine to other components.
* FCC and CE approved using STP cable (for twisted pair products)
Kramer

distributors, visit our Web site: www.kramerelectronics.com,
where updates to this user manual may be found. We welcome your questions, comments and feedback.
Safety Warning: Disconnect the unit from the power supply before opening/servicing.

P/N: 2900-000183 REV 2
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.