Kramer Electronics, Ltd.

Models:
TP-200, XGA Line Receiver


This addendum describes the Power Connect feature used with Kramer machines, and the choice between STP and UTP CAT5 cables.
The Power Connect feature lets you power a transmitter / receiver system by connecting just one power adapter to either the transmitter or the receiver. The other unit is fed over the same CAT5 cable.
The Power Connect feature applies as long as the CAT5 cable is heavy gauge cable (that is, it can carry power). The distance does not exceed 50 meters on standard cable.
For a distance of 100 meters, separate power supplies must be connected to the transmitter and to the receiver simultaneously, unless using heavy gauge CAT5 cable.
The decision whether to use shielded twisted pair (STP) cable or unshielded twisted pair (UTP) cable depends on the nature of the application.
It is recommended that in applications with high interference, shielded twisted pair (STP) cable will give better results. However, the shield itself does create a capacitance that degrades the frequency response of the machines. For shorter distances, of 50m or so, shielded twisted pair (STP) cable is preferred because it provides protection from interference (degradation is non-apparent).
For a long range application, unshielded twisted pair (UTP) cable is preferred. However, the unshielded twisted pair (UTP) cable should be installed far away from electric cables, motors etc., which are prone to create electrical interference.
1 This section of the addendum is only relevant to machines that support this feature (for example, the TP-104; not the
P/N: 2900 – 9999991 A1

Welcome to Kramer Electronics (since 1981): a world of unique, creative and affordable solutions to the infinite range of problems that confront the video, audio and presentation professional on a daily basis. In recent years, we have redesigned and upgraded most of our line, making the best even better! Our 350-plus different models now appear in 8 Groups1, which are clearly defined by function.
In addition to our high quality twisted-pair interfaces, like the TP-100 XGA Line Transmitter and the TP-200 XGA Line Receiver, we also offer excellent switchers and matrices, distribution amplifiers, presentation processors, remote controllers and computer-related products. Congratulations on purchasing your Kramer TP-100 XGA Line Transmitter and the TP-200 XGA Line Receiver. These products are ideal for utilizing existing UTP cabling that results in an efficient, fast and uncluttered environment for:
The package includes the following items:
We recommend that you:
Video, Audio, VGA/XGA Processors; GROUP 4: Interfaces and Sync Processors; GROUP 5: Twisted Pair Interfaces;
GROUP 6: Accessories and Rack Adapters; GROUP 7: Scan Converters and Scalers; and GROUP 8: Cables and Connectors
2 Download up-to-date Kramer user manuals from the Internet at this URL: http://www.kramerelectronics.com/manuals.html
3 The complete list of Kramer cables is on our Web site at http://www.kramerelectronics.com (click “Cables and Connectors”
in the Products section)
Introduction

The TP-100 XGA Line Transmitter and TP-200 XGA Line Receiver constitute an extendable branching set of VGA/XGA-to-Twisted Pair Transmitter and Receiver. The input looping capability of the TP-100 and the transceiving ability of the TP-200 create a multimode XGA/CAT5 distribution system.
The TP-100 XGA Line Transmitter includes:
The TP-200 XGA Line Receiver:
Achieving the best performance means:
Overview

Your XGA Line Transmitter and the XGA Line Receiver
Figure 1, Table 1 and Table 2 define the TP-100:

1 Sometimes laptop computers refuse to output a VGA signal to an external VGA monitor. By setting the ID Bit to ON (and
using pin # 4 on the VGA connector that is normally unused), the laptop computer will output to an external VGA monitor
2 For looping select Hi-Z
3 Using a UTP cable with CAT5 connectors at both ends

Your XGA Line Transmitter and the XGA Line Receiver
Figure 2, Table 3 and Table 4 define the TP-100:




Connecting a XGA/CAT5 Distribution System
To configure a XGA/CAT5 distribution system consisting of two TP-100 XGA Line Transmitter units and two (transceiver) TP-200 XGA Line Receiver units, as Figure 3 illustrates, do the following:
1 Push in the ID Bit button to ON
2 Release the Term button to HI-Z on the first unit and push in the Term button to 75 Ω on the second unit


Connecting a XGA/CAT5 Distribution System

Table 5 defines the technical specifications1:
1 Specifications for 30m of CAT5 UTP cable, unless otherwise specified
2 Specifications are subject to change without notice
Technical Specifications

Kramer Electronics (hereafter Kramer) warrants this product free from defects in material and workmanship under the following terms.
Labor and parts are warranted for three years from the date of the first customer purchase.
Only the first purchase customer may enforce this warranty.
Except as below, this warranty covers all defects in material or workmanship in this product. The following are not covered by the warranty: 1. Any product which is not distributed by Kramer, or which is not purchased from an authorized Kramer dealer. If you are uncertain as to whether a dealer is authorized, please contact Kramer at one of the agents listed in the web site www.kramerelectronics.com 2. Any product, on which the serial number has been defaced, modified or removed. 3. Damage, deterioration or malfunction resulting from: i) Accident, misuse, abuse, neglect, fire, water, lightning or other acts of nature ii) Product modification, or failure to follow instructions supplied with the product iii) Repair or attempted repair by anyone not authorized by Kramer iv) Any shipment of the product (claims must be presented to the carrier) v) Removal or installation of the product vi) Any other cause, which does not relate to a product defect vii) Cartons, equipment enclosures, cables or accessories used in conjunction with the product
WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR
We will pay labor and material expenses for covered items. We will not pay for the following: 1. Removal or installations charges. 2. Costs of initial technical adjustments (set-up), including adjustment of user controls or programming. These costs are the responsibility of the Kramer dealer from whom the product was purchased. 3. Shipping charges.
1. To obtain service on you product, you must take or ship it prepaid to any authorized Kramer service center. 2. Whenever warranty service is required, the original dated invoice (or a copy) must be presented as proof of warranty coverage, and should be included in any shipment of the product. Please also include in any mailing a contact name, company, address, and a description of the problem(s). 3. For the name of the nearest Kramer authorized service center, consult your authorized dealer.
All implied warranties, including warranties of merchantability and fitness for a particular purpose, are limited in duration to the length of this warranty.
The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option. Kramer shall not be liable for: 1. Damage to other property caused by defects in this product, damages based upon inconvenience, loss of use of the product, loss of time, commercial loss; or: 2. Any other damages, whether incidental, consequential or otherwise. Some countries may not allow limitations on how long an implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations and exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from place to place. NOTE: All products returned to Kramer for service must have prior approval. This may be obtained from your dealer. This equipment has been tested to determine compliance with the requirements of: EN-50081: "Electromagnetic compatibility (EMC); generic emission standard. Part 1: Residential, commercial and light industry" EN-50082: "Electromagnetic compatibility (EMC) generic immunity standard. Part 1: Residential, commercial and light industry environment". CFR-47: FCC Rules and Regulations: Part 15: “Radio frequency devices Subpart B – Unintentional radiators”
⌦ Servicing the machines can only be done by an authorized Kramer technician. Any user who makes changes or modifications to
the unit without the expressed approval of the manufacturer will void user authority to operate the equipment. ⌦ Use the supplied DC power supply to feed power to the machine. ⌦ Please use recommended interconnection cables to connect the machine to other components.

distributors, visit our Web site: www.kramerelectronics.com