EN
Kramer Electronics logo
Official user manual

Kramer Electronics TP-100

12 pages·573 KB·Satellite Radio·PDF·ENDEFRITNLJA
Kramer Electronics TP-100
Table of Contents 29 sections USER MANUAL · Models: · TP-100, XGA Line Transmitter · TP-200, XGA Line Receiver · … ShowHide
Page 1 of the Kramer Electronics TP-100 user manual — TP-100, XGA Line Transmitter
Page 1 · click to enlarge
Page 1

Kramer Electronics, Ltd.

Kramer Electronics TP-100 — USER MANUAL diagram (page 1)
Fig. 1

USER MANUAL

Models:

TP-100, XGA Line Transmitter

TP-200, XGA Line Receiver

Page 3 of the Kramer Electronics TP-100 user manual — TP-100)
Page 3 · click to enlarge
Page 3

ADDENDUM: Included with user manuals for machines with a CAT5 connector

This addendum describes the Power Connect feature used with Kramer machines, and the choice between STP and UTP CAT5 cables.

Power Connect Feature 1

The Power Connect feature lets you power a transmitter / receiver system by connecting just one power adapter to either the transmitter or the receiver. The other unit is fed over the same CAT5 cable.

The Power Connect feature applies as long as the CAT5 cable is heavy gauge cable (that is, it can carry power). The distance does not exceed 50 meters on standard cable.

For a distance of 100 meters, separate power supplies must be connected to the transmitter and to the receiver simultaneously, unless using heavy gauge CAT5 cable.

Shielded Twisted Pair (STP) / Unshielded Twisted Pair (UTP)

The decision whether to use shielded twisted pair (STP) cable or unshielded twisted pair (UTP) cable depends on the nature of the application.

It is recommended that in applications with high interference, shielded twisted pair (STP) cable will give better results. However, the shield itself does create a capacitance that degrades the frequency response of the machines. For shorter distances, of 50m or so, shielded twisted pair (STP) cable is preferred because it provides protection from interference (degradation is non-apparent).

For a long range application, unshielded twisted pair (UTP) cable is preferred. However, the unshielded twisted pair (UTP) cable should be installed far away from electric cables, motors etc., which are prone to create electrical interference.

1 This section of the addendum is only relevant to machines that support this feature (for example, the TP-104; not the

TP-100)

P/N: 2900 – 9999991 A1

Page 4 of the Kramer Electronics TP-100 user manual — 2 Getting Started
Page 4 · click to enlarge
Page 4

1 Introduction

Welcome to Kramer Electronics (since 1981): a world of unique, creative and affordable solutions to the infinite range of problems that confront the video, audio and presentation professional on a daily basis. In recent years, we have redesigned and upgraded most of our line, making the best even better! Our 350-plus different models now appear in 8 Groups1, which are clearly defined by function.

In addition to our high quality twisted-pair interfaces, like the TP-100 XGA Line Transmitter and the TP-200 XGA Line Receiver, we also offer excellent switchers and matrices, distribution amplifiers, presentation processors, remote controllers and computer-related products. Congratulations on purchasing your Kramer TP-100 XGA Line Transmitter and the TP-200 XGA Line Receiver. These products are ideal for utilizing existing UTP cabling that results in an efficient, fast and uncluttered environment for:

  • Studios, airports, offices and hospitals
  • Security and military applications

The package includes the following items:

  • TP-100 XGA Line Transmitter and/or TP-200 XGA Line Receiver
  • Power cord(s)
  • This user manual 2 and the Kramer concise product catalog/CD

2 Getting Started

We recommend that you:

  • Unpack the equipment carefully and save the original box and packaging materials for possible future shipment
  • Review the contents of this user manual
  • Use Kramer high performance high resolution cables 3
1 GROUP 1Distribution Amplifiers; GROUP 2: Video and Audio Switchers, Matrix Switchers and Controllers; GROUP 3:

Video, Audio, VGA/XGA Processors; GROUP 4: Interfaces and Sync Processors; GROUP 5: Twisted Pair Interfaces;

GROUP 6: Accessories and Rack Adapters; GROUP 7: Scan Converters and Scalers; and GROUP 8: Cables and Connectors

2 Download up-to-date Kramer user manuals from the Internet at this URL: http://www.kramerelectronics.com/manuals.html

3 The complete list of Kramer cables is on our Web site at http://www.kramerelectronics.com (click “Cables and Connectors”

in the Products section)

Introduction

Page 5 of the Kramer Electronics TP-100 user manual — 3 Overview
Page 5 · click to enlarge
Page 5

3 Overview

The TP-100 XGA Line Transmitter and TP-200 XGA Line Receiver constitute an extendable branching set of VGA/XGA-to-Twisted Pair Transmitter and Receiver. The input looping capability of the TP-100 and the transceiving ability of the TP-200 create a multimode XGA/CAT5 distribution system.

The TP-100 XGA Line Transmitter includes:

  • A looping XGA input (with termination switch)
  • ID Bit control
  • 2 CAT5 outputs for simultaneous signal transmission to 2 locations
  • Individual cable EQ. control for each CAT5 output

The TP-200 XGA Line Receiver:

  • Receives the CAT5 signal, decodes it and simultaneously distributes it to 3 XGA outputs and relays the input to the next receiver (transceiver operation)
  • Includes an EQ. control for the decoded XGA signal and an EQ. control for the signal re-transmitted to the next receiver

Achieving the best performance means:

  • Connecting only good quality connection cables, thus avoiding interference, deterioration in signal quality due to poor matching, and elevated noise levels (often associated with low quality cables)
  • Avoiding interference from neighboring electrical appliances that may adversely influence signal quality and positioning your TP-100 and/or TP-200 in a location free from moisture and away from excessive sunlight and dust

Overview

Page 6 of the Kramer Electronics TP-100 user manual — 4 Your XGA Line Transmitter and the XGA Line Receiver
Page 6 · click to enlarge
Page 6

Your XGA Line Transmitter and the XGA Line Receiver

4 Your XGA Line Transmitter and the XGA Line Receiver

Figure 1, Table 1 and Table 2 define the TP-100:

Kramer Electronics TP-100 — 4 Your XGA Line Transmitter and the XGA Line Receiver diagram (page 6)
Fig. 2 · 4 Your XGA Line Transmitter and the XGA Line Receive…
Figure 1TP-100 XGA Line Transmitter
Table 1Front Panel TP-100 XGA Line Transmitter Features
FeatureFunction POWER SwitchIlluminated switch supplying power to the unit Out 2 EQ. KnobAdjusts the equalization control level (EQ.) for the CAT5 Line 2 output Out 1 EQ. KnobAdjusts the equalization control level (EQ.) for the CAT5 Line 1 output
Table 2Rear Panel TP-100 XGA Line Transmitter Features
FeatureFunction XGA Input HD15 Connector Connects to the video source ID Bit (OFF / ON) Button Pushing in selects the ID BIT (when outputting a VGA signal from a laptop to an external VGA monitor1); releasing deactivates the ID BIT Term (Hi-Z / 75Ω) Button Pushing in selects 75Ω; releasing selects Hi-Z2 XGA Loop HD15 Connector For looping to a VGA acceptor Line 1 OUT CAT5 Connector Connects to the Line IN connector on the TP-200 XGA Line Receiver3 Line 2 OUT CAT5 Connector Connects to the Line IN connector on the TP-200 XGA Line Receiver3 Power Connector withFUSE AC connector enabling power supply to the unit

1 Sometimes laptop computers refuse to output a VGA signal to an external VGA monitor. By setting the ID Bit to ON (and

using pin # 4 on the VGA connector that is normally unused), the laptop computer will output to an external VGA monitor

2 For looping select Hi-Z

3 Using a UTP cable with CAT5 connectors at both ends

Page 7 of the Kramer Electronics TP-100 user manual — 4 Your XGA Line Transmitter and the XGA Line Receiver
Page 7 · click to enlarge
Page 7

Your XGA Line Transmitter and the XGA Line Receiver

Figure 2, Table 3 and Table 4 define the TP-100:

Kramer Electronics TP-100 — 4 Your XGA Line Transmitter and the XGA Line Receiver diagram (page 7)
Fig. 3 · 4 Your XGA Line Transmitter and the XGA Line Receive…
Figure 2TP-200 XGA Line Receiver
Table 3Front Panel TP-200 XGA Line Receiver Features
#FeatureFunction 1POWER SwitchIlluminated switch supplying power to the unit 2Line Out EQ. KnobAdjusts the equalization control level (EQ.) for the signal transmitted via the CAT5 Line output to the next XGA Line Receiver 3XGA Out EQ. KnobAdjusts the equalization control level (EQ.) for the decoded XGA signal
Kramer Electronics TP-100 — 4 Your XGA Line Transmitter and the XGA Line Receiver diagram (page 7)
Fig. 4 · 4 Your XGA Line Transmitter and the XGA Line Receive…
Table 4Rear Panel TP-200 XGA Line Receiver Features
# FeatureFunction 1 Line IN CAT5 Connector Connects to the Line OUT connector on the XGA Line Transmitter 2 Line OUT CAT5 Connector Connects to the Line IN connector on the next XGA Line Receiver 3 XGA OUT 1 HD15 Connector Connects to the video acceptor 1 4 XGA OUT 2 HD15 Connector Connects to the video acceptor 2 5 XGA OUT 3 HD15 Connector Connects to the video acceptor 3 6 Power Connector with FUSE AC connector enabling power supply to the unit
Kramer Electronics TP-100 — 4 Your XGA Line Transmitter and the XGA Line Receiver diagram (page 7)
Fig. 5 · 4 Your XGA Line Transmitter and the XGA Line Receive…
Page 8 of the Kramer Electronics TP-100 user manual — 5 Connecting a XGA/CAT5 Distribution System
Page 8 · click to enlarge
Page 8

Connecting a XGA/CAT5 Distribution System

5 Connecting a XGA/CAT5 Distribution System

To configure a XGA/CAT5 distribution system consisting of two TP-100 XGA Line Transmitter units and two (transceiver) TP-200 XGA Line Receiver units, as Figure 3 illustrates, do the following:

1. Connect a XGA source (for example, a laptop 1 ) to the XGA Input connector on the first TP-100 XGA Line Transmitter unit.
2. Connect the first TP-100 XGA Line Transmitter unit’s XGA Loop connector to the XGA Input connector on the second TP-100 XGA Line Transmitter unit 2 .
3. Connect the first TP-100 XGA Line Transmitter unit’s Line 1 OUT connector to the Line IN connector on the first TP-200 XGA Line Receiver unit.
4. Connect the first TP-100 XGA Line Transmitter unit’s Line 2 OUT connector to the Line IN connector on an additional TP-200 XGA Line Receiver unit.
5. Connect the first TP-200 XGA Line Receiver unit’s Line OUT connector to the Line IN connector on the second TP-200 XGA Line Receiver unit.
6. Connect the XGA outputs on both TP-200 Line Receiver units to their respective XGA acceptors.
7. Connect the power cord on each unit to the electricity supply.

1 Push in the ID Bit button to ON

2 Release the Term button to HI-Z on the first unit and push in the Term button to 75 Ω on the second unit

Page 9 of the Kramer Electronics TP-100 user manual — 5 Connecting a XGA/CAT5 Distribution System
Page 9 · click to enlarge
Page 9
Kramer Electronics TP-100 — 5 Connecting a XGA/CAT5 Distribution System diagram (page 9)
Fig. 6 · 5 Connecting a XGA/CAT5 Distribution System
Figure 3Multimode XGA/CAT5 Distribution System

Connecting a XGA/CAT5 Distribution System

Page 10 of the Kramer Electronics TP-100 user manual — 6 Technical Specifications
Page 10 · click to enlarge
Page 10

6 Technical Specifications

Table 5 defines the technical specifications1:

Table 5Technical Specifications 2 of the TP-100 / TP-200
NPUTS:TP-100: 1 XGA input on an HD15F connector; 1 XGA Loop on an HD15F connector TP-200: 1 UTP CAT5 connector (Line IN) UTPUTS:TP-100: 2 UTP CAT5 connectors (Line 1 OUT; Line 2 OUT) TP-200: 1 UTP CAT5 connector (Line OUT); 3 XGA outputs on HD15F connectors MAX. OUTPUT LEVEL:1.5 Vpp / 75Ω IFF. GAIN (Pair):0.23% (optimum) IFF. PHASE (Pair):0.19 Deg (optimum) -FACTOR (Pair):<0.05% (optimum) /N RATIO (Pair):70dB (optimum) ESOLUTION:Up to UXGA ANGE:Up to 150m with CAT5 UTP ONTROLS:(30m): TP-100: Line Out E.Q.: 0 to 7.8dB @ 20MHz TP-200: XGA Out E.Q.: 0 to 3.2dB @ 20MHz OUPLING:DC OWER SOURCE:TP-100 / TP-200: 230 VAC, 50/60 Hz. (115VAC, U.S.A.) 13 VA IMENSIONS:22cm x 18cm x 4.5cm (8.6” x 7” x 1.8”), W, D, H. WEIGHT:1.2 kg. (2.65 lbs.) approx. CCESSORIES:Power cords PTIONS:19” rack adapters RK-80 (holds two units)

1 Specifications for 30m of CAT5 UTP cable, unless otherwise specified

2 Specifications are subject to change without notice

Technical Specifications

Page 11 of the Kramer Electronics TP-100 user manual — CAUTION!
Page 11 · click to enlarge
Page 11

LIMITED WARRANTY

Kramer Electronics (hereafter Kramer) warrants this product free from defects in material and workmanship under the following terms.

HOW LONG IS THE WARRANTY

Labor and parts are warranted for three years from the date of the first customer purchase.

WHO IS PROTECTED?

Only the first purchase customer may enforce this warranty.

WHAT IS COVERED AND WHAT IS NOT COVERED

Except as below, this warranty covers all defects in material or workmanship in this product. The following are not covered by the warranty: 1. Any product which is not distributed by Kramer, or which is not purchased from an authorized Kramer dealer. If you are uncertain as to whether a dealer is authorized, please contact Kramer at one of the agents listed in the web site www.kramerelectronics.com 2. Any product, on which the serial number has been defaced, modified or removed. 3. Damage, deterioration or malfunction resulting from: i) Accident, misuse, abuse, neglect, fire, water, lightning or other acts of nature ii) Product modification, or failure to follow instructions supplied with the product iii) Repair or attempted repair by anyone not authorized by Kramer iv) Any shipment of the product (claims must be presented to the carrier) v) Removal or installation of the product vi) Any other cause, which does not relate to a product defect vii) Cartons, equipment enclosures, cables or accessories used in conjunction with the product

WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR

We will pay labor and material expenses for covered items. We will not pay for the following: 1. Removal or installations charges. 2. Costs of initial technical adjustments (set-up), including adjustment of user controls or programming. These costs are the responsibility of the Kramer dealer from whom the product was purchased. 3. Shipping charges.

HOW YOU CAN GET WARRANTY SERVICE

1. To obtain service on you product, you must take or ship it prepaid to any authorized Kramer service center. 2. Whenever warranty service is required, the original dated invoice (or a copy) must be presented as proof of warranty coverage, and should be included in any shipment of the product. Please also include in any mailing a contact name, company, address, and a description of the problem(s). 3. For the name of the nearest Kramer authorized service center, consult your authorized dealer.

LIMITATION OF IMPLIED WARRANTIES

All implied warranties, including warranties of merchantability and fitness for a particular purpose, are limited in duration to the length of this warranty.

EXCLUSION OF DAMAGES

The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option. Kramer shall not be liable for: 1. Damage to other property caused by defects in this product, damages based upon inconvenience, loss of use of the product, loss of time, commercial loss; or: 2. Any other damages, whether incidental, consequential or otherwise. Some countries may not allow limitations on how long an implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations and exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from place to place. NOTE: All products returned to Kramer for service must have prior approval. This may be obtained from your dealer. This equipment has been tested to determine compliance with the requirements of: EN-50081: "Electromagnetic compatibility (EMC); generic emission standard. Part 1: Residential, commercial and light industry" EN-50082: "Electromagnetic compatibility (EMC) generic immunity standard. Part 1: Residential, commercial and light industry environment". CFR-47: FCC Rules and Regulations: Part 15: “Radio frequency devices Subpart B – Unintentional radiators”

CAUTION!

⌦ Servicing the machines can only be done by an authorized Kramer technician. Any user who makes changes or modifications to

the unit without the expressed approval of the manufacturer will void user authority to operate the equipment. ⌦ Use the supplied DC power supply to feed power to the machine. ⌦ Please use recommended interconnection cables to connect the machine to other components.

Page 12 of the Kramer Electronics TP-100 user manual — P/N: 2900-000100 REV 1
Page 12 · click to enlarge
Page 12

For the latest information on our products and a list of Kramer

distributors, visit our Web site: www.kramerelectronics.com

Updates to this user manual may be found at http://www.kramerelectronics.com/manuals.html We welcome your questions, comments and feedback.

Kramer Electronics TP-100 — For the latest information on our products and a list of Kramer diagram (page 12)
Fig. 7 · For the latest information on our products and a lis…

Kramer Electronics, Ltd. Web site: www.kramerelectronics.com

E-mailinfo@ kramerel.com

P/N: 2900-000100 REV 1

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Kramer Electronics TP-100

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Kramer Electronics TP-100

Be the first to ask — other owners or our team will answer.

Original document

Kramer Electronics TP-100 manual PDF

12 pages·573 KB·Satellite Radio·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…