Residential/Commercial Generator Sets Models: 12RESM1 12/17/18RESL 12/17/18RESNT 12/18RESHD Controller: DC-RET Digital Control TP-6516 4/09d Installation.
Engine exhaust from this product contains chemicals known to the State of California to cause cancer , birth defects, or other reproductive harm. W ARNING California Proposition 65 Product Identification Information Generator Set Ident ification Numbers Record the product identification numbers from the generator set nameplate(s).
T able of Contents TP-6516 4/09 T able of Contents 3 Product Identification Information 2 .......................................................... Safety Precautions and Instructions 5 ........................................................ Introduction 9 .
TP-6516 4/09 4 Notes.
TP-6516 4/09 5 Safet y Precautions and Instruct ions Safety Precautions and Instructions IMPORT ANT SAFETY INSTRUCTIONS. Electromechanical equipment, including generator sets, transfer switches, switchgear , and accessories, can cause bodily harm and pose life-threatening danger when improperly installed, operated, or maintained.
TP-6516 4/09 6 Safet y Precautions and Instruct ions Battery gases. Explosion can cause severe injury or death. Battery gases can cause an explosion. Do not smoke or permit flames or sparks to occur near a battery at any time, particularly when it is charging.
TP-6516 4/09 7 Safet y Precautions and Instruct ions Hazardous Noise Hazardous noise. Can cause hearing loss. Never operate the generator set without a muffler or with a faulty exhaust system. CAUTION Engine noise. Hazardous noise can cause hearing loss.
TP-6516 4/09 8 Safet y Precautions and Instruct ions Hot Parts Hot engine and exhaust system. Can cause severe injury or death. Do not work on the generator set until it cools. W ARNING Servicing the exhaust system. Hot parts can cause severe injury or death.
TP-6516 4/09 9 Introduction This manual provides installation instructions for 12, 17, and 18 kW residential/commercial generator sets equipped with the Kohler r DC-RET Digital Control. Refer to TP-6517, Operation Manual, for generator set operation and maintenance instructions.
TP-6516 4/09 10 12 5 42 0 16 6 3 13 24 17 19 14 15 22 ADV-7341A-B 10 25 23 9 21 18 Control detail, top view 8 11 7 12 1. Muf fler 2. Oil check 3. Oil fill 4. Air cleaner 5. Spark plug locations (bot h sides) 6. Oil filter 7. Oil cooler location 8. DC-RET Digital Cont rol display 9.
TP-6516 4/09 11 Service Assistance For professional advice on generator set power requirements and conscientious service, please contact your nearest Kohler distributor or dealer . D Consult the Y ellow Pages under the heading Generators—Electric. D Visit the Kohler Power Systems website at KohlerPower .
TP-6516 4/09 12 Notes.
TP-6516 4/09 13 Section 1 I nstallation Section 1 Installation 1.1 General Have an authorized distributor/dealer install the generator set outdoors according to the instructions in this manual. The generator set installation must comply with the National Electrical Code (NEC) and local code requirements.
TP-6516 4/09 14 Section 1 Inst allation Note: Fuel system may differ from drawing. See Section 1.7. Figure 1-2 Generator Set Mounting Details and Dimensions, 12 kW Models, ADV -7466, Sheet 1.
TP-6516 4/09 15 Section 1 I nstallation Figure 1-3 Generator Set Clearances, 12 kW Models, ADV -7466, Sheet 2.
TP-6516 4/09 16 Section 1 Inst allation Figure 1-4 Generator Set Mounting Details and Dimensions, 17/18 kW Models, ADV -7341-B, Sheet 1.
TP-6516 4/09 17 Section 1 I nstallation Figure 1-5 Generator Set Clearances, 17/18 kW Models, ADV -7341-B, Sheet 2.
TP-6516 4/09 18 Section 1 Inst allation 1.4.1 Exhaust Requirements Carbon monoxide. Can cause severe nausea, fainting, or death. The exhaust system must be leakproof and routinely inspected. W ARNING Generator set operation. Carbon monoxide can cause severe nausea, fainting, or death.
TP-6516 4/09 19 Section 1 I nstallation 1.6 Fuel Requirements The generator set operates using natural gas or LP vapor fuel. The generator set is EP A-certified for both natural gas and LP vapor fuels. The fuel system installation must comply with the NEC and local codes.
TP-6516 4/09 20 Section 1 Inst allation 1.6.2 Fuel Pipe Size Ensure that the natural gas pipe size and length meet the specifications in Figure 1-13 or Figure 1-14. Measure the pipe length from the primary gas pressure regulator to the pipe connection on the generator set fuel inlet.
TP-6516 4/09 21 Section 1 I nstallation Procedure to Convert from NG to LP 1. Place the generator set master switch in the OFF position. 2. Disconnect the power to the battery charger . 3. Disconnect the generator set engine starting battery , negative ( - - ) lead first.
TP-6516 4/09 22 Section 1 Inst allation 9. Connect and turn on the new fuel supply . 10. Check that the generator set master switch is in the OFF position. 1 1. Reconnect the generator set engine starting battery leads, negative ( - -) lead last. 12. Reconnect power to the battery charger .
TP-6516 4/09 23 Section 1 I nstallation 1. Junction box 2. Field connection term inal block location (see Figure 1-20) 3. Suggested elect rical inlet ADV-7341 2 1 3 12 kW 17/18 kW ADV-7466 1 2 3 Figure 1-19 Field Wiring Figure 1-20 Field-Connection T erminal Block 1.
TP-6516 4/09 24 Section 1 Inst allation 1.9 Battery Sulfuric acid in batteries. Can cause severe injury or death. Wear protective goggles and clothing. Battery acid may cause blindness and burn skin. W ARNING Explosion. Can cause severe injury or death.
TP-6516 4/09 25 Section 1 I nstallation Note: The generator set will not start and circuit board damage may occur if the battery is connected in reverse. Figure 1-22 shows the location of the engine starting battery . Standard battery cables provide easy connection to the battery .
TP-6516 4/09 26 Section 1 Inst allation 1.10 Carburetor Heater (optional) Have accessories installed by an authorized distributor/ dealer or a licensed electrician. F ollow the installation instructions provided with each kit. U se s eparate conduit for AC and DC leads to reduce the possibility of electrical interference.
TP-6516 4/09 27 Section 1 I nstallation GM19463 1 1. Thermostat 2. Connector 3. Heater 3 12 kW Carburetor Heater 1 3 17/18 kW Carburetor Heater GM57968 2 Figure 1-26 Carburetor Heaters 1.1 1 Prestart Installation Check Review the entire installation section.
TP-6516 4/09 28 Section 1 Inst allation Notes.
TP-6516 4/09 29 Section 2 Wiring Diagram s Section 2 Wiring Diagrams Figure 2-1 lists the wiring diagram drawing numbers and drawing references. Wiring Diagram Description Drawing Number Reference Pag.
TP-6516 4/09 30 Section 2 Wiring Diagrams - Figure 2-2 Schematic Diagram, 12 kW Models, ADV -7351.
TP-6516 4/09 31 Section 2 Wiring Diagram s - Figure 2-3 Point-to-Point Wiring Diagram, 12 kW Models, GM52471.
TP-6516 4/09 32 Section 2 Wiring Diagrams - Figure 2-4 Schematic Diagram, Single Phase, 17/18 kW Models, ADV -7353.
TP-6516 4/09 33 Section 2 Wiring Diagram s Figure 2-5 Point-to-Point Wiring Diagram, Single Phase, 17/18 kW Models, GM52541.
TP-6516 4/09 34 Section 2 Wiring Diagrams Notes.
TP-6516 4/09 Appendix 35 Appendix A Abbreviations The following list contains abbreviations that may appear in this publication. A, amp ampere ABDC aft er bottom dead center AC alternating current A/D analog to digital ADC advanced digital control; analog to digital convert er adj.
TP-6516 4/09 36 Appendix k kilo (1000) K kelvin kA kiloampere KB kilobyte (2 10 bytes) KBus Kohler comm unication protocol kg kilogram kg/cm 2 kilogram s per square centimet er kgm kilogram-met er kg/.
TP-6516 4/09 37 Notes.
TP-6516 4/09 38 Notes.
.
E 2007, 2008, 2009 by Kohler Co. A ll rights reserved. TP-6516 4/09d KOHLER CO. Kohler , Wisconsin 53044 Phone 920-565-3381, Fax 920-459-1646 For the nearest sales/service outlet in the US and Canada, phone 1-800-544-2444 KohlerPower .
An important point after buying a device Kohler 12RESM1 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Kohler 12RESM1 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Kohler 12RESM1 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Kohler 12RESM1 you will learn all the available features of the product, as well as information on its operation. The information that you get Kohler 12RESM1 will certainly help you make a decision on the purchase.
If you already are a holder of Kohler 12RESM1, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Kohler 12RESM1.
However, one of the most important roles played by the user manual is to help in solving problems with Kohler 12RESM1. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Kohler 12RESM1 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center